View Bid Results For Lead Ducts Tenders

We found 894 Bid Results related to lead ducts tenders. You can find Contractor details who won lead ducts tenders along with contract details in Bid awards announcements section.

Filters
Stage
660
150
84
Tender Publishing Platform
28
866
State / UT
30
129
107
86
64
54
53
48
46
42
32
28
25
24
19
18
16
14
12
12
9
9
9
7
6
6
4
4
4
4
3
Contract Value
244
75
393
179
Publish Date
1
0
0
0
0
Sector
28
399
92
88
52
47
40
39
27
16
14
13
11
11
8
6
6
5
4
3
2
2
2
2
1
1
1
1
1
Ownership
6
408
279
106
96
3
2
Within keyword
Active filters:
Showing 1–18 of 894 tenders matching your filters
1.
Defence #11427184 Technical Bid
Tender for Sch A Part-I To Xi Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Internal Water Supply) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (Sewage Disposal ) , Total Amount Of Sch A Part-Ix (External Water Supply) , Total Amount Of Sch A Part-X (External Electric Supply) , Total Amount Of Sch A Part-Xi (Hot Water Supply) , Schedule A Part-Xii (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , Supply And Fix Engineering Body Desert Cooler Electric Driven Single Phase 230 Volts, Having Nominal Air Flow Capacity Of 4500 Cum Per Hour,Tank Capacity 105 Ltrs,With Auto Louver Movement,With Min Ait Throw 15 Mtr Complete All As Specified And As Directed By Engr-In- Charge. Make:Kenstar Turbocool Neo Hc 105 Or Techno Commercial Equivalent Make. , Supply, Installation, Commissioning Refrigerator, Electric Driven (Single Phase),Capacity 340 Ltrs , Double Door, Smart Inverter Compressor Of Latest Model, Eco Friendly , Digital Display, Toughened Glass Shelves Complete With All Accessories All As Specified And Directed By Engineer In Charge. , Supply Installation, Commissioning Of Metal Top Deep Freezer Double Door Single Phase Storage Type Deep Freezer 320 Ltrs Cap Of Latest Model Complete With All Accessories All As Specified And Directed. , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva All As Specified And Directed , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. , Design, Fabricate, Supply, Install, Testing And Commissioning Of Complete Electrical Chimney/Electrical Hood With Filters Comprising Of Following Items. A) Supply,Install,Testing And Commisssioning Of Kitchen Hood Made Ss 304 Matt Finish 1 Mm Thick Wall Mounted Type With Removable Grease Stop And Fixing Brackets,Oil Drain Channel Of Size 36 X 72 Of Required Length Including Drain Collector & Connecting With Exhaust Ducting Etc Complete All As Specified And As Directed-2 Rm B) Supply And Install Removable Grease Stop Filters Suitable Size Complete All As Specified And As Directed- 02 Nos C) Supply,Install,Testing And Commissioning Exhaust Blower Of Capacity 1 Hp ,240 Volts Single Phase 1440 Rpm Connecting With Exhaust Ducting And Suitable Copper Cable Connecting Complete All As Specified And As Directed:-01 Nos D) Supply And Installation Collar Damper Of Suitable Size For Connecting Between Duct And Exhaust Hood Made Out Of 20 Swg Complete All As Specified And As Directed.-02 Nos E) Supply And Fix Anti Vibration Dush With Ms Fabricated Stand Frame Of Suitable Size For Resting Blower Complete All As Specified And As Directed. , Supply And Install Exhaust Ducting Of Size 500 Mm X 500 Mm Made Of Gi Sheet 24 Swg Including Connecting With Ceiling Mounted Exhaust Hood Up To Terrace With Ms Angle Frame 25 X 25 X 3 Mm Thick,Fixing Of Brackets With Nut Bolts,Gaskets Supporting Thread Rod,Channels Etc,Including Painting The Steel Surfaces With Two Coats Of Synthitic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Taps, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down High Pressure With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S&F Health Faucet (Abs Body) Suitable For 15 Mm Dia Pipe With 1 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified. , S&F Two Way Bib Tap 15Mm Dia, With Wall Flange And Aerator Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. , S&F Wall Mixer For Mixing Hot And Cold Water And Bend For Connecting To Shower,15 Mm Bore Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S & F Flush Cock, Push Type 15Mm Dia, Cast Copper Alloy, Fancy Type, Chromium Plated, For Iron/Cpvc Pipe Or Unions Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Tap With Swan Neck, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down With Long Screwed Shanks And Fly Nuts Screwed For Iron/Cpvc Pipe And Fixed Complete All As Specified And As Directed. , S & F In Replacement Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , S & F Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 10 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb Four Pole 25 Ka, 100 annual periodical maintenance With Fixed Thermal And Magnetic Settings As Incomer Ip43 Protection Double Door : Plain 4 Way With Suitable Rated Busbar,Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separetely. , S&F In Replacement, Mccb 4 Pole, 415 V, Adjustable Type, 100 Amps With Breaking Capacity 25 Ka And Making Connection With Suitabl Size Of Copper Lugs Etc Complete All As Specified And As Directed. , M&L For Construction Of New Reinforced Cement Concrete Septic Tank For 50 Users Designed To Carry Sewage And Sludge Water, Plain Cement Concrete 1:4:8 Below Foundation, Reinforced Cement Concrete Roof Slab Including Beams, Etc, Using Tmt Crs Bars Grade Fe-500D/Fe-550D, With Vent Shaft , Manhole Opennings With Cover Connection, Including Excavation Earthwork In Any Type Of Soil/ Ordinary Rock Complete All As Shown On Td Drg. Afb/Td/228/2018(S) Sheet 1R/1 Of Ce (Af) Bangalore Zone And As Specified By Engineer-In-Charge. , M&L For Construction Of Soakage Well, Including Excavation In Any Type Of Soil/Ordinary Rock, Foundation In Plain Cement Concrete 1:3:6 Walls Of Honeycomb Masonry With Top Ring Of M-25 Concrete Including Intersepting Chamber Screen Chamber Made Of Fly Ash Brick Masonry In C:M 1:4, Rcc/Dwc Complete Filled With Brick Bats Of Size Of Size 1.80M Dia And 3.0 M Effective Depth All As Shown On Drawing No Cepz/2019/Td/03 Sheet No 1/2 And 2/2 And As Specified By Engineer-In-Charge. , S&F Of Grease Trap Of Capacity 500Lts Having Length X Width X Height Of 1150 X 939 X 765 Mm, To Be Installed Underground Complete All As Specified And As Directed By Engineer-In-Charge. Make : Supreme, Cat No Rlugtp0500gb And Equivalent Series As Approved By Engineer-In-Charge. Note: (A) Excavation, Plain Cement Concrete And Brickwork For Installing Grease Trap To Be Paid Separately Under Respective Items. , Cutting Existing 150 Mm Dia Di Pipe For Inserting Tee Of Size 150X150x50 Mm Including Lead Joint And Excavation Etc Complete All As Specified And Directed , M&L For Construction Of Valve Pit/Chamber Of Internal Dimensions 900 Mm X 900 Mm X 900 Mm, Using Plain Cement Concrete 1:4:8, Type D-2, Using 40Mm Graded Stone Aggregates For Foundation, 23 Cm Thick, Brick Wall Built In Cement Mortar (1:4) ,15 Mm Thick Rendering All Around The Brick Work In Cement Mortar (1:6), 75 Mm Thick Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregates In Coping Including Necessary Form Work, 3 Coats Of White Wash On Rendered Surfaces And On Coping, 5 Mm Thick Mild Steel Top Sheet Cover With Frame Made Out Of 40X40x6 Mm Angle Iron, Locking Arrangement, Including Painting Of Steel Surface With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Maharashtra View Result →
2.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
3.
Health and Family Welfare #11302925 AOC
Bids Are invited for Procurement Of Miscellaneous Items For Various Department - A C Cannula , Abgel (Absorbent Gelatin Sponge) , Ambu Bag Adult , Ambu Bag Paediatric , Ambu Bag With Facemask With Reservior , Antimicrobial Incise Drape 10Cm*15Cm. , Antimicrobial Incise Drape 60Cm*45Cm , Antimicrobial Incise Drape 90Cm*45Cm , Antimicrobial Incise Mini Adhesive , Aspiration Needle 10 G , Aspiration Needle 12 G , Aspiration Needle 14 G , Aspiration Needle 16 G , Aspiration Needle 18 G , Aspiration Needle 19 G , Aspiration Needle 20 G , Auto Clave Indicator Tape , B.P. Cuff Pediatric , B.P. Cuff Adult , Bactigrass , Bandage Cloth (Than)100Cmt*20Mtr , Bandage Gauze 4 , Bandage Gauze 6 , Baxter Infusion 5Ml 1Hr.Pump For Tkr Surgery , Blood Tranfusions Set , Blurex (Tryphan Blue) , Cathetor Mount , Cervical Coller Large , Cervical Coller Medium , Cervical Coller Small , Cervical Traction Belt , Colostomy Bag , Cord Cl , Corrugetted Drain , Cotton 500 Gm Roll , Cotton Soft Roll 4 , Cotton Soft Roll 6 , Dial-A-Flow , Digital X-Ray Film 10*12 , Digital X-Ray Film 12*15 , Digital X-Ray Film 8*10 , Disposable Closed Circuit Tubings , Disposable Endotracheal Tubes Size 2 Plain , Disposable Endotracheal Tubes Size 2 5 Plain , Disposable Endotracheal Tubes Size 3 Plain , Disposable Endotracheal Tubes Size 3 5 Plain , Disposable Endotracheal Tubes Size 4 Cuffed , Disposable Endotracheal Tubes Size 4 Plain , Disposable Endotracheal Tubes Size 4 5 Cuffed , Disposable Endotracheal Tubes Size 4 5 Plain , Disposable Endotracheal Tubes Size 5 Cuffed , Disposable Endotracheal Tubes Size 5 5 Cuffed , Disposable Endotracheal Tubes Size 5 Plain , Disposable Endotracheal Tubes Size 6 Cuffed , Disposable Endotracheal Tubes Size 6 5 Cuffed , Disposable Endotracheal Tubes Size 7 Cuffed , Disposable Endotracheal Tubes Size 7 5 Cuffed , Disposable Endotracheal Tubes Size 8 Cuffed , Disposable Endotracheal Tubes Size 8 5 Cuffed , Disposable Endotracheal Tubes Size 9 Cuffed , Disposable Endotracheal Tubes Size 9 5 Cuffed , Disposable Face Mask , Disposable Iv Set , Disposable Ot Gown , Disposable Suction Bottle No 10 , Disposable Suction Bottle No 12 , Disposable Suction Bottle No 14 , Disposable Suction Bottle No 16 , Disposable Scalp Vein No 18 , Disposable Scalp Vein No 20 , Disposable Scalp Vein No 22 , Disposable Scalp Vein No 23 , Disposable Scalp Vein No 24 , Disposable Sterile Bivalve Connection Plastic 3 Way Stopcock , Disposable Sterile Epidural Minipack System No 16 , Disposable Sterile Epidural Minipack System No18 , Disposable Sterile Half Gown , Disposable Sterile Intra Cathetor I V Canula No 18 , Disposable Sterile Intra Cathetor I V Canula No 20 , Disposable Sterile Intra Cathetor I V Canula No 22 , Disposable Sterile Intra Cathetor I V Canula No 24 , Disposable Sterile Needle 16 , Disposable Sterile Needle 18 , Disposable Sterile Needle 20 , Disposable Sterile Needle 21 , Disposable Sterile Needle 22 , Disposable Sterile Needle 23 , Disposable Sterile Needle 24 , Disposable Sterile Needle 25 , Disposable Sterile Needle No. 26 , Disposable Sterile Plastic Appron , Disposable Suction Cathetor No 10 , Disposable Suction Cathetor No 12 , Disposable Suction Cathetor No 14 , Disposable Suction Cathetor No 16 , Disposable Suction Cathetor No 18 , Disposable Suction Cathetor No 20 , Disposable Suction Cathetor No 6 , Disposable Suction Cathetor No 8 , Disposable Surgeons Cap Green, White,Blue , Distilled Water , Dynaplast 4 (Zinc Adhesive Plaster) , Dynaplast 6 ( Zinc Adhesive Plaster) , Ecg Gelly , Ecg Leads Electrodes (Adult) , Ecg Leads Electrodes (Peadiatric) , Ecg Roll Size 106*20 , Ecg Roll Size 210*20 , Edta Tubes For Blood Collection , Elastoplast Ortho Creap Bandage 8Cm*4Mt. , Elbow Sling , Epiduaral Set Combine (Cse Set No.18) , Eusol , Examination Gloves Large , Examination Gloves Medium , Examination Gloves Small , Extention Tubing For O2 , Eye Drape , Eye Shield , Face Mask Anatomical Size 3,4,5 , Face Mask For Preterm & Term , Flatus Tube , Flexometallic Tubes No.7 , Flexometallic Tubes No.7.5 , Flexometallic Tubes No. 5.5 , Flexometallic Tubes No. 6 , Flexometallic Tubes No.5 , Flexometallic Tubes No.6.5 , Foldable Lenses From No.16 To 24.5 , Foleys Cathetore No 10Fr. (Silicon) , Foleys Cathetore No 12(Silicon) , Foleys Cathetore No 14 (Silican) , Foleys Cathetore No 16 (Silicon) , Foleys Cathetore No 18(Silicon) , Foleys Cathetore No 6Fr. (Silicon) , Foleys Cathetore No 8Fr.(Silicon) , Gauze Cloth Than 90Cmt*18Mtr. (Gamjee) , Glucostrips , Gum Elastic Bougie Adult , High Conc. O2 Mask , Hiv Kit With Goggles, , Hot Water Bag , Hydrogen Peroxide , Ice Coller , Ice Pack Cap For Fever Petiants , Infant Feeding Tube No 10 , Infant Feeding Tube No 12 , Infant Feeding Tube No 4 , Infant Feeding Tube No 5 , Infant Feeding Tube No 6 , Infant Feeding Tube No 7 , Infant Feeding Tube No 8 , Infant Feeding Tube No 9 , Insulin Syringe 100 Iu , L.S.Belt Medium , L.S.Belt Small , Laryngeal Mask Airways No 2 , Laryngeal Mask Airways No 2 5 , Laryngeal Mask Airways No 3 , Laryngeal Mask Airways No 4 , Laryngeal Mask Airways No 5 , Laryngeoscope Blade (00 -Preterm), (0- Term) , Lgel 2 , Lgel 3 , Lgel 4 , Lma Supreme All Size , Micropore 1 , Micropore 2 , Micropore 3 , Micropore Tape 1Inch With Cutter , Micropore Tape 2Inch With Cutter , Micropore Tape 3Inch With Cutter , N95 Mask , Nasal Prone Adult , Nasal Prone Pediatric , Nebulizer Mask Adult , Nebulizer Mask Pediatric , Neonatal Ambu Bag , Nerve Block Needle 22G B- Braun , Nesal Pack , Net Cell 8 Cm , North Pole Tube 5, 5.5, 6,6.5 , Nst Paper For Fetal Monitor , O2 Mask With Tubing , Opthalmic Blade Cresent , Opthalmic Blade Keratome 2.8Mm , Opthalmic Blade Side Port , Opthalmic Tunnel Blade 2 1Mm , Paper Adhesive Sticking 2 , Paper Adhesive Sticking 4 , Paper Adhesive Sticking 6 , Pdiadrip , Pelvic Traction Belt , Pen Needle For Diabeties , Peripheral Inserted Central Catheter , Peripheral Nerve Locator Needle Size 10Cm , Peripheral Nerve Locator Needle Size 5Cm, , Plain Rubber Catheter , Plain Tubes For Blood Collection With Clot Activator (Red Cap) , Plaster Pop 4 Inch , Plaster Pop 6 Inch , Plastic Appron , Plastic Stylet Large Size , Plastic Stylet Medium Size , Plastic Stylet Small Size , Prisoft Cotton Roll 4 , Prisoft Cotton Roll 6 , Rebreathing Bag All Size , Rigid Lenses From No.+ 18 To 26 , Sillicone Folley Cathetor 10 , Sillicone Folley Cathetor 12 , Sillicone Folley Cathetor 14 , Sillicone Folley Cathetor 16 , Rubber Cathetor Plain All Sizes , Rubber Tits Bag , Ryles Tube Sterile Disposable 10Fr , Ryles Tube Sterile Disposable 12Fr , Ryles Tube Sterile Disposable 14Fr , Ryles Tube Sterile Disposable 16Fr , Ryles Tube Sterile Disposable 18Fr , Ryles Tube Sterile Disposable 20Fr , Ryles Tube Sterile Disposable 8Fr , Shoulder Sling , Silastic Sheet 2 1 05 , Silicon Rubber Catheter , Skin Grafting Blade , Skin Stapler , Sodim Fluorite Blood Collection Tube , Sodium Citrate Blood Collection Tube 2Ml To 5Ml , Solvent Ether , Sonography Gelly (Usg Jelly) , South Pole Tube 5, 5.5, 6,6.5 , Spinal Needle No.16 , Spinal Needle No.17 , Spinal Needle No.18 , Spinal Needle No.19 , Spinal Needle No.20 , Spinal Needle No.21 , Spinal Needle No.22 , Spinal Needle No.23 , Spinal Needle No.24 , Spinal Needle No.25 , Steelet For Et Tube Small , Steelet For Et Tube Medium , Steelet For Et Tube Large , Steridrape ( Plastic Green Bed Sheet) , Sterile Hypodermic Syringes 10 Ml Leur Lock , Sterile Hypodermic Syringes 10Ml , Sterile Hypodermic Syringes 1Ml , Sterile Hypodermic Syringes 20Ml , Sterile Hypodermic Syringes 2Ml , Sterile Hypodermic Syringes 2Ml Leur Lock , Sterile Hypodermic Syringes 50Ml , Sterile Hypodermic Syringes 5Ml , Sterile Hypodermic Syringes 5Ml Leur Lock , Sterile Rubber Glove No 6 , Sterile Rubber Glove No 6 .5 , Sterile Rubber Glove No 7 , Sterile Rubber Glove No 7.5 , Sterile Rubber Glove No 8 , Sterile Rubber Glove No 8.5 , Steristrips , Stocking Double Xl Size , Stocking Large Size , Stocking Medium Size , Stocking Small Size , Stocking Xl Size , Strile Dressing Gauze Pad 2*2 , Strile Dressing Gauze Pad 3*3 , Strile Dressing Gauze Pad 4*4 , Suction Vacume Conector , Surgical Blade No 11 , Surgical Blade No 12 , Surgical Blade No 15 , Surgical Blade No 20 , Surgical Blade No 21 , Surgical Blade No 22 , Taping Long Syringe 50Cc , Thoson S Splint , Tournequete Band , Tr.Benzoin , Tracheostomy Tube All Size Disposable , Traction Weight 1Kg To 15 Kg , Transperent Sticking For Iv Line , Trop - T Kit , Trusynith 1 0 , Trusynith 2 0 , Tuberculin Syring 1Ml , Underpad , Urine Bag , Urine Pregnancy Test (Upt) , Umbilical Vein Catheter , Umbilical Artery Catheter , Woven Confirming Retention Bandage 8 Cm X 3 5 Mt. Stretched , Yanker Suction Tube , Leg U Drape For Tkr Surgery 260Cm*300Cm , Vicryl No 3 0 With Cutting Needle , Vicryl No 2 0 With Cutting Needle , Vicryl No 1 0 With Cutting Needle , Categut No 3 0 With Round Needle , Categut No 2 0 With Round Needle , Categut No 1 0 With Round Needle , Proline Black Silk 3 0 1 0 2 0 With Cutting Needle , Chromic Catgut 1 0 , Chromic Catgut 2 0 , Chromic Catgut 4 0 , Ethilon 10 0 , Ethilon 1 0 , Ethilon 1 , Ethilon 2 , Ethilon 3 0 , Synthetic Polyglactine With Needle Hlf Circle Round Body Heavy Needle 50 Mm Size 1 90 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body50 Mm Size 1 90 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body90 Mm Size 1 90 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body40 Mm Size 1 90 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body40 Mm Size 1 0 90 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body40 Mm Size 3 0 70 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body26 Mm Size 3 0 70 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body12 Mm Size 4 0 70 Cm , Synthetic Polyglycolic Acid With Needle Hlf Circle Round Body16mm Size 5 0 70 Cm , Polydiaxone Suture Hlf Circle Roud Body Heavy Needle 45 Mm Size 190Cm , Polydiaxone Suture Hlf Circle Roud Body Heavy Needle 20 Mm Size 30 90Cm , Polyglyconate Monofilament Synthetic Absorbable Suture Size 1 90Cmgreen 48Mm Hlf , Polyglyconate Monofilament Synthetic Absorbable Suture Size 1 0 90Cmgreen 48Mm Hlf Round Body , Polyglyconate Monofilament Synthetic Absorbable Suture Size 4 0Cmgreen 75Cm Hlf Taper Point Round Body , Glycomer Monofilament Absorbable Suture Size 1 0 90 Cm Hlf 37Mmtaperpoint Roundbody , Glycomer Monofilament Absorbable Suture Size 1 90 Cm Hlf 40Mmtaperpoint Roundbody , Braided Coated Polyglactin Undyed Fast Absorbing 3 0 70 Cmhlf Circle Cutting 22 Mm , Non Absorbable Microsuture Monofilament Nylone Csu 3 8Doube Needle 6Mm Size 10 0 38 Cm , Plypropylene Suture Hlf Circle Tapercut Heavy Needle 30 Mmsize 1 100 Cm , Plypropylene Suture Hlf Circle Tapercut Heavy Needle 40 Mmsize 1 70 Cm , Polypropylene Mesh 15 X 15 Cm , Polypropylene Mesh 30 X 30 Cm , Polypropylene Mesh 3 X 6 Cm , Composite Mesh 10 X 15 Cm , Composite Mesh 15 X 15 Cm , Composite Mesh 25 X 20 Cm , Chromic Catgut With Needle Round Body 40Mm Size 76Cm , Chromic Catgut With Needle Round Body 50Mm Size 100Cm , Chromic Catgut With Needle Round Body 76Mm Size 100Cm , Chromic Catgut With Needle Round Body 40Mm Size 1/0 , Chriomic Catgut With Needle Round Body 30Mm Size 1/0 , Chromic Catgut With Needle Round Body 30Mm Size 2/0 , Chromic Catgut With Needle Round Body 76Mm Size 2/0 , Chromic Catgut With Needle Round Body 40Mm Size 2/0 , Chromic Catgut With Needle Round Body 76Mm Size 3/0 , Black Braided Silk With Needle Circle Reverse Cutting 45Mm Size 2/0 76Mm , Polyglyconate Monofilament Synthetic Absorbable Suture Size 1, 90Cm Green 48Mm 1/2 , Polyglyconate Monofilament Synthetic Absorbable Suture Size 1-0, 90Cm Green 48Mm 1/2 Round Body , Polyglyconate Monofilament Synthetic Absorbable Suture Size 4-0Cm Green 75Cm 1/2 Taper Point/Round Body , Glycomer, Monofilament Absorbable Suture Size 1-0, 90Cm 1/2 37Mm Taperpoint Roundbody , Glycomer, Monofilament Absorbable Suture Size 1-0, 90Cm 1/2 40Mm Taperpoint Roundbody , Braided Coated Polyglactin Undyed Fast Absorbing 3-0 70Cm 1/2 Circle Cutting 22Mm , Non Absorbable Microsuture Monofilament Nylone. Csu 3/8 Double Needle 6Mm Size 10/0 38Cm , Plypropylene Suture 1/2 Circle Taercut Heavy Needle 30 Mm Size 1 100 Cm , Plypropylene Suture 1/2 Circle Taercut Heavy Needle 40 Mm Size 1 70 Cm , Hernia Mesh Fixation Device Complete Absorbable Mesh Fixation Device With Minimum 25 Permenent Straps , Multidirectional Skin Stapler With 35 Wide Staples Coated With Krytox And Having Alignment Idicator Staple Dimension Of 6.9X3.9 And 0.58 Mm Wire Diameter , Barbour Linen Thread No 40 , Barbour Linen Thread No 60 , Barbour Linen Thread No 80 , Synthtic Polygalactin With Needle Half Circle To Round Body Heavy Needle 40Mm Size 90 Cm Vicryl 3-0 , Non Absorbable Polyamide Surgical Reverse Cutting 70Cm Ethilon 2-0 , Non Absorbable Polyamide Surgical Reverse Cutting 100Cm Ethilon 1-0 , Absorbable Surgical Suture(Synthtic) Vicryl Breaded, Coated Polyglatin 910,90Cm Half Circle Rapid Vicryl , Synthtic Polygalactin With Reverse Cutting Needle 40Mm,90Cm Vicryl 3-0 , Synthtic Polygalactin With Reverse Cutting Needle 40Mm,90Cm Vicryl 4-0 , Synthtic Polygalactin With Reverse Cutting Needle 40Mm,90Cm Vicryl 5-0 , Synthtic Polygalactin With Reverse Cutting Needle 40Mm,90Cm Vicryl 6-0 , Non Absorbable Monofilament Polyamide Surgical Cutting Ethilon 2-0 , Non Absorbable Monofilament Polyamide Surgical Reverse Cutting Ethilon 2-0 , Non Absorbable Monofilament Polyamide Surgical Cutting Ethilon 3-0 , Non Absorbable Monofilament Polyamide Surgical Reverse Cutting Ethilon 3-0 , Non Absorbable Monofilament Polyamide Surgical Cutting Ethilon 4-0 , Non Absorbable Monofilament Polyamide Surgical Reverse Cutting Ethilon 4-0 , Non Absorbable Monofilament Polyamide Surgical Cutting Ethilon 5-0 , Non Absorbable Monofilament Polyamide Surgical Reverse Cutting Ethilon 5-0 , Non Absorbable Monofilament Polyamide Surgical Cutting Ethilon 6-0 , Non Absorbable Monofilament Polyamide Surgical Reverse Cutting Ethilon 6-0 , Non Absorbable Monofilament Polypropylene Blue Reverse Cutting 60Mm Straight Reverse Cutting Prolene 3-0 , Non Absorbable Monofilament Polypropylene Blue Reverse Cutting 60Mm Straight Reverse Cutting Prolene 4-0 , Non Absorbable Monofilament Polypropylene Blue Reverse Cutting 60Mm Straight Reverse Cutting Prolene 5-0 , Non Absorbable Monofilament Polypropylene Blue Reverse Cutting 60Mm Straight Reverse Cutting Prolene 6-0 , Monocryl ( Poliglecaprone) Ethilon 2-0 , Monocryl ( Poliglecaprone) Ethilon 3-0 , Monocryl ( Poliglecaprone) Ethilon 4-0 , Proline 1 Round Body , Proline 1 Cutting Needle , Proline 1-0 Round Body , Proline 1-0 Cutting Needle , Proline 2-0 Round Body , Proline 2-0 Cutting Needle , Proline 3-0 Round Body , Proline 3-0 Cutting Needle , Proline 4-0 Round Body , Proline 4-0 Cutting Needle , Proline 5-0 Round Body , Proline 5-0 Cutting Needle , Proline 6-0 Round Body , Proline 6-0 Cutting Needle , Proline 7-0 Round Body , Proline 7-0 Cutting Needle , Proline 8-0 Round Body , Proline 8-0 Cutting Needle , Proline 9-0 Round Body , Proline 9-0 Cutting Needle , Proline Mesh 6Cm*11Cm , Vicryl 0 Round Body , Vicryl 0 Cutting Needle , Vicryl 1 Round Body , Vicryl 1 Cutting Needle , Vicryl 1-0 Round Body , Vicryl 1-0 Cutting Needle , Vicryl 2-0 Round Body , Vicryl 2-0 Cutting Needle , Vicryl 3-0 Round Body , Vicryl 3-0 Cutting Needle , Vicryl 4-0 Round Body , Vicryl 4-0 Cutting Needle , Vicryl 5-0 Round Body , Vicryl 5-0 Cutting Needle , Vicryl 6-0 Round Body , Vicryl 6-0 Cutting Needle , Vicryl 7-0 Round Body , Vicryl 7-0 Cutting Needle , Vicryl 8-0 Round Body , Vicryl 8-0 Cutting Needle , Rapid Vicryl Half Circle , Ethilon 1 Round Body (Nylon) , Ethilon 1 Cutting Needle , Ethilon 1-0 Round Body , Ethilon 1-0 Cutting Needle , Ethilon 2-0 Round Body , Ethilon 2-0 Cutting Needle , Ethilon 3-0 Round Body , Ethilon 3-0 Cutting Needle , Ethilon 4-0 Round Body , Ethilon 4-0 Cutting Needle , Ethilon 5-0 Round Body , Ethilon 5-0 Cutting Needle , Ethilon 6-0 Round Body , Ethilon 6-0 Cutting Needle , Ethilon 7-0 Round Body , Ethilon 7-0 Cutting Needle , Ethilon 8-0 Round Body , Ethilon 8-0 Cutting Needle , Chromic Catgut 1-0 , Monocryl 2-0 (Polyglecaprone)Round Body , Monocryl 3-0 Round Body , Monocryl 3-0 Cutting Needle , Monocryl 4-0 Round Body , Monocryl 4-0 Cutting Needle , A V Retractor , Adson Dissecting Forceps , Adson Dressing Forceps , Adson Forceps , Adson Forceps 1:2 , Adson Tissue Forceps , Allice Fercep , Allis Tissue , Allis Tissue Forceps , Artery Forceps , Auvard Speculum , Auvard Vaginal Retractor , Auvard Weighted Speculum, 2 1/2Lbs (1136G) , B P Handles , Babcock Forcep , Babcock Tissue Forceps , Baby Allis Tissue Forceps , Baby Farabeuf Retractor , Baby Metzenbaum Scissors , Baby Mixter Forceps , Backhaus Towel Cl , Balfour Retractor , Bard Parker Handle , Bonney Dissecting Forceps , Bozeman Uterine Dressing Forceps , Brinkerhoff Rectal Speculum Medium , Brown Adson Tissue Forceps , Cats Paw Set Of 2 , Chances Curved Artery Forceps , Chati Aluminium , Chealte Forceps , Chealte Forceps Container , Chittle Conteiner , Chittle Forcep , Clip Remover Steapler , Cns Tray Hammer , Cns Tray Tunning Fork , Cord Cutting Scissor , Cord Cutting Scissor Ear Speculum , Cord Cutting Scissor Nasal Speculum , Cord Cutting Scissor Tongue Depresser , Crile Forceps , Crile Hemostatic Forceps , Crile Wood N.H. , Cushing Dressing Forceps , Deaver Retractor , Debakey Tissue Forceps , Dissecting Forceps , Dissecting Scissors , Doyens Bladder Retractor , Dressing Forceps , Dunhills Artery Forceps , Female Catheter , Forceps Holder , Forster Sponge Forceps , Frazier Fergusson Suction Tube , Galabin Uterine Sound , Gallipot , Gemini-Mixter Forceps , Goelet Retractor , Graves Vaginal Speculum, Medium Size , Green Armitage Forceps , Greenhag Ovum Forceps , Halsted Mosquito Forceps , Heaney Hysterectomy Forceps 8 1/4 (21Cm), Double Tooth , Heaney Needle Holder 8 (20.3Cm), Cvd, Carb-N-Sert Jaws , Heaney-Simon Retractor 11 1/2 (29.2Cm) , Hegar Uterine Dilators , Hernia Mesh Fixation Device Complete Absorbale Mesh Fixationdevice With Minimum 25 Permenent Straps , Hirschman Anscope , Hosley Needle Holder , Instrument Box , Iris Scissors , Jansen Retractor , Joseph Skin Hook , Kelly Forceps , Kelly Retractor , Knife Handle , Knife Handle No 3 , Knife Handle No 4L , Kochers Tissue Forceps 1:2 , Lahey Gall Duct Forceps , Lane Dissecting Forceps , Lane Forceps 1:2 , Lane Tissues Forceps , Langen Beck Retractor Set Of 2 , Langenbeck Retractor , Ligature Scissors , Little Wood Tissue Forceps , Magyls Forcep , Mayo Dissecing Scissors , Mayo Hagar Needle Holder , Mayo Pins , Mayo Scissors Tc , Mayo Towel Clips , Mcindoe Forceps 15Cm , Metzenbaum Disecting Scissors , Metzenbaum Scissors , Metzenbaum Scissors Tc , Mixter Forceps , Morris Retractor , Multidirectional Skin Stapler With 35 Wide Staples Coated With Krytox And Having Alignment Idicator Staple Dimension Of 6 9 X3 9 And 0 58 Mm Wire Diameter , Needle Holder Medium Size , Needle Holder Mayo Hegar , Operating Scissor , Packed In A Perforatted Sterilizing Box , Pediatric Balfour Retractor , Pediatric Deaver Retractor , Pediatric Ribbon Retractor , Plain Forcep , Plastic Surgery Scissors , Playfair Uterine Probe , Poole Suction Tube , Ragnell Scissors , R Ley Sponge Forceps , R Ley Sponge Holding Forceps , Ribbon Retractor , Richardson Retractor , Rochester Ochsner Forceps , Rochester Pean Forceps , Rochester-Pean Forceaps 8 (20.3Cm), Cvd , Russian Tissue Forceps , Sawyer Rectal Retractor , Scalpel Handle , Schnidt Tonsil Forceps , Schroder Braun Tenaculum Forceps 9 1/2 (24.1Cm) Str , Scissoer Disecting Curve , Scissoer Episiotomy Scissoer , Scissoer Suture Cutting St Big , Scissoer Suture Cutting St Small , Scissors, Mayo Straight , Senn Retractor , Sims Needle Holder , Sims Speculum , Sims Uterine Sound, Gard In Cm , Sims Vaginalspeculum , Single Hook Retracter Set Of 2 , Sinus Forceps , Spencer Wells , Spencer Wells Artery Forceps , Sponge Holding Forceps , Ss Articles Artery Forcep Medium Curve , Ss Articles Artery Forcep Medium Straight , Ss Articles Mosquito Small Curve , Ss Articles Mosquito Small Straight , Stainless Steel Container , Stainless Steel Ruler , Stich Removal Scissor , Stitch Scissors , Suction Artistatic Tube , Teale Vulsellum , Thumb Dressing Forceps , Tissue Forceps , Tooth Forcep Medium , Towel Clips , Trevers Dissecting Forceps , Tounge Depressor , U.S. Army Retractor , U.S. Army Retractor Set Of 2 , Uterine Curettes , Uterine Depressor , Uterine Vulsellum Forceps , Vant Polypus Forceps , Webster Needle Holder , Weitlaner Retractor , Bed , Ule Cutter , B P Apparatus Digital , B P Apparatus Manual , B P Handle Regulater 4No Long , B P Handle Regulater 6No Long , Back Rest , Bacterial Viral Filters Hme , Bains Circuit , Barine Anastesia Circuit , Basing Big Ss , Bed Blocks , Bed Pan Ss , Bipap Machine Portable , Blood S Le Carry Rack With Tray , Bowl Small Ss , Bowl Medium Ss , Bowl Large Ss , Cardiac Moniter Vital Nibp Respiration Sp O2 Ecg , Catheterization Tray , Cell Counter , Defibrillator , Dial Flow Regulater , Ecg Machine Automatic 12 Leads , Electric Inhaler Steamer , Enema Can With Connector , Flow Meter , Fogging Machine , Fogging Machine For Icu , Glucometer , Gyser Water Heater 25 Ltr , Gyser Water Heater 5 Ltr , Hegars Dilator , Humidifier , Injection Burn Machine , Kidney Dish , Kidney Tray Ss , Laryngoscope Adult , Laryngoscope Handle , Laryngoscope Paediatric , Laryngoscope With Blade All Size , Lenen H Er , Lumbar Puncture Tray , Macintosh Lartngoscope Size 3,4 , Multipara Moniter B.P. Cuff Adult , Multipara Moniter B.P. Cuff Pediatric , Nebulisation Set , Nedlle Destroyer Machine , Nelsans Inhalor , Nibp Circuit Cube And Cable , O2 Spanner , Oxygen Concentrater , Oxygen Cylinder , Oxygen Cylinder Trolly , Oxygen Flowmeter , Pie Disk , Plaster Cutter , Plaster Spreader , Proctoscope , Pulse Oximeter , Puncture Proff Container 5 Ltr , Puncture Proof Container For Sharp , Resuscitation Kit , Ryles Tube Tray , S S Drum Small , Ss Drum Medium , Ss Drum Large , S S Tray Medium , S S Tray Large , S S Tray Small , Screen Bed Side , Semi Auto Analyzer , Small Sterlizer , Medium Sterlizer , Large Sterlizer , Spraying Machine , Stainless Steel Water Tank With Tap 50 Liter , Steel Tray With Lid Small , Steel Tray With Lid Medium , Steel Tray With Lid Large , Steriliger Midium Portable Autoclave Machine , Stethoscope Adult , Stethoscope Pediatric , Suction Machine Electronic , Syring Cutter , Syringe Pump , Thermometer Clinical , Thermometer Digital , Thermometer Mercury , Urine Pot Urinal Male Plastic , Venous Section Tray , Walker , Weight Machine Adult , Weight Machine Pediatric , Wheel Chair Standard Size , X Ray View Box , X Ray View Box 20 By 20 , X Ray Developer , X Ray Fixer , Enamel Tray Small , Enamel Tray Medium , Enamel Tray Large , B P Handle Regulater 4No Long , B P Handle Regulater 6No Long , Cardiac Moniter Vital Nibp Respiration Sp O2 Ecg , Screen Bed Side (Frame) , Sterliger Midium Portable Autoclave Machine , 2 Shelve Instrument Trolley , 3 Shelve Instrument Trolley , Dressing Trolley , Medicine Trolley , Led Examination Light For Medical Use , Patient Warmer , Air Matress , Woods L S , Z Fold Ecg Paper Roll , Examination Glove , T Connection , Air Cushion , Niv Mask Small , Niv Mask Medium , Niv Mask Large , Mackintosh Rubber , Hangers ( 8X10 / 10X12 / 12X15 ) , Emergency Light , Shadowless L , Medicine Container Small , Medicine Container Medium , Medicine Container Large , Biodegradable Dustbin Bag ( Black / Yellow / Red ) , Artificial Anterior Chamber , Endothelial Punch , S Marker Dsaek , Serrated Jaw Forceps , 0.2Micro Sterilizing Filter , 2.8 Mm Keratome (Microtrek/Medilec) , 20 Degree Indirect Opthalmoscopy Lens , 20 G Busin Forceps , 20 G Busin Spatula , 60 Ml Pars Plana Syringe , 90 Degree Indirect Opthalmoscopy Lens , A C Maintainer , Alcon Monarch 3/4 Iol Delivery System , Angled Vanas Scissors , B Octa Ring , Bandage Contact Lens , Barbies Retractor , Bard Parker Handle Ophthalmic , Barraquer De Laage Needle Holder , Basal Salt Solution 0.05% Ophthalmic , B-Hex Ring , Bimanual Canula , Bone Punch All Sizes , Bonn Moria Forceps , Bowmans Probe , Brillant Blue Green Dye Fpr Intraocular Use , Busin Punch , C3f8 And Sf6 Gas Cannister Retina , Capsular Tension Ring , Castrovejo Corneal Scissors , Collibri Forceps , Conjunctival Scissors , Corneal Trephines All Sizes , Cornisol , Cyanoacrylate Glue , De Weckers Scissor , Desmarres Lid Retractor , Dialer , Disposable Canula 23,25 G. , Disposable Trochar 23,25 G. , Dmek 90 Degree Spatula , Dsaek Reverse Sinsky Hook , Dsaek Surgery Set , Eiitation Forceps , Endolaser Probe Retina , Epilation Forceps , Fibrin Glue , Fluorescence Dye Stain Strips , Flute Needle With Handle , Gonioscopy Mirror Lens , Graffes Mucle Hook , Haldipurkar Forceps , Hockey Stick Knife , Hydro Cannuala , Ilm Forceps Disposable , Indocyanine Green Dye , Injection Riboflavin Hypotonic , Injection Riboflavin Isotonic , Intracameral Moxifloxacin Injection(Pf) , Iris Claw Holding Forcep , Iris Hooks , Iris Repositor , Jamesons Muscle Hook , Kellys Punch , Knapps Strabismus Scissors , Landers Lens For Vitrectomy , Lid Plate , Lieberman Eye Speculum , Light Pipe Retina , Lims Forceps , Mcphersons Suture Tying Forceps , Micro - Rhexis Forceps , Micro - Rhexis Scissor , Microcorneal Scissors , Moody Curve Fixation Forceps , Mosquito Artery Cl , Muscle Hooks , Mvr Blade , Mysol Pfs Injection For Intra Ocular Use , Osher Y Hooks , Pediatric Speculum , Periosteal Elevator , Pfcl (Per Fluro Carbon Liquids) , Phaco Chopper , Phenocaine Plus Injection , Pic Forceos , Pierce Hoskins Forceps , Plain Curved Suture Tying Forceps , Plain Straight Suture Tying Forceps , Punctal Dilator , Pva Sponge Spears , Retina Green Laser , Rose Bengal Dye Stain Strips , Schirmirs Strip , Silicone Band 240 With Sleeve , Silicone Buckle , Silicone Intubation Set , Silicone Oil 1500 And 5000 , Stabilization Ring , Stevens Hook Mucle , Suction Trephine , Teflon Block , Tissue Marker , Toothed Fixation Forceps , Toothed Straight Fixation Forceps , Toric Marker , Triamcilone Acetonide Inj. ( Aurocort) , Utarata Forceps , Vanas Scissor , Vernier Calliper , Viscoat Injection (Sodium Hyaluronate For Intraoccular Use) , Vitrectomy Cutter 23,&25 Gauze Pneurmatic Cutter Make Appaswami , Vitrectomy Infusion Canula , Vitrectomy Lippes Loop , Vitrectomy Microscissors , Vitrectomy Spatula , Vtrectomy Pick Forceps , Wescott Tenotomy Scissor , Wescotts Spring Scissors , Wire Speculum , Vicryl 2347 , Nst Machine , Mva Syringe , Dilator Set , Disposable Romovac Suction Bottle No 8 , Disposable Romovac Suction Bottle No 10 , Chromic Catgut 3 0 , Fetal Doppler , Vision Drum , X Ray Lead Appron , Ecg Cl , Wooden Tounge Depresser , Opthalmic Tonometer , Vegino Speculum Cuscos , Insulin Syringe 6 Ml , Examination Gloves Exta Small Size , Indirect Optholmoscope , Formalin Solutions , Non Sterile Plastic Container ( Stool ) 30Ml , Disposable Blue Bedsheet , Pricking Lancet , Urostomy Bag , Long Elbow Cuff , Vaccume Cleaner Machine , Fogger Machine , Cotton Sticking 3 , Cotton Sticking 6 , Bcg Syringe , Et Tube Neonate 02 , Et Tube Neonate 2.5 , Et Tube Neonate 03 , Et Tube Neonate 3.5 , Et Tube Neonate 04 , Et Tube Neonate 4.5 , Nasograstric Tubes No. 8 , Nasograstric Tubes No. 10 , L.S Belt Long , L.S Belt Xl , Cidex Solution , Knee Brace With Hinges Small , Knee Brace With Hinge Medium , Knee Brace With Hinge Long , Knee Brace With Hinge Xl , Leg Traction Brace Small , Leg Traction Brace Medium , Leg Traction Brace Long , Soft Cervical Coller , Clavicle Brace Small , Clavicle Brace Medium , Clavicle Brace Long , Ankle Support , Forearm Brace , Knee Cap Small , Knee Cap Medium , Knee Cap Long , Knee Cap Xl , Ride On Sweeper , Walk Behind Sweepers Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 1.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
4.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
5.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
6.
Educational and Research Institute #11273270 Technical Bid
Tender For Civil Work At Mgsss, Ratanpura Block Rajgarh- 1 Part A Civil Work 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 P.C.C. In Foundation Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:4 Coarse Sand :8 Gradeed Stone Aggregate 40 Mm Nominal Size). 4 Brick Masonry With F.P.S. Bricks Of Class Designation 75 In Foundation And Plinth With Bricks Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) 5 Dpc:-Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required Excluding The Cost Of Centering, Shuttering And Reinforcement . M20 Grade Nominal Mix/Design Mix. 6 Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc. Good Soil Of Earth 7 Brick Work In Super Structure Upto Five Storey With Selected Bricks Of Class Designation 75 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10Mm. Wide 12Mm. Deep Complete In Cement Mortar 1:6. Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Add Extra Over Item Of Brick Work With Class Designation 100 In Substitution Of Class Designation 75 : 8 Pillar Masonary :-Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And All Sides Are Free 9 Stone Kharanja: Rr Dry Stone Kharanja Under Floor 10 Lintel Beams:-Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( As Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 11 Slab & Beam:-Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( As Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 12 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. 13 Steel Reinforcement:-P/F Reinforcement For Rcc Work Including Straightening,Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Upto Floor Five Leve Tmt Bars (Conforming Of Relevent Is Code). 14 Door Frames:- Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M), Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Angle Iron (40X40X5Mm. @ 3 Kg/M) 15 Doors:-Providing And Fixing M.S. Sheet 1 Mm Thick Double Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint. Add Extra For Double Leaf Shutters 16 Glazed Window:Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13X3Mm, 10Cm. Long Embedded In Cement Concrete Block 15X10X10Cm. Of 1:3:6 (1Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :Partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] 17 Wire Gauge Supplying & Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150 Mm Distance. 18 Guard Bars: P&F Square Bars Or Other Flat Welded To Window/Ventilators Etc. 19 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 20 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab From 2001 To 5000 Sqcm 21 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish : 12Mm Thick. 22 External Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 20 Mm Thick 23 Plaster(Ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1 Cement: 3 Fine Sand) 24 Black Board : Plaster On New Surface On Wall In Cement Sand Mortar 1:3 Including Raking Of Joints Etc. Complete Fine Finish: 12 Mm Thick 25 Grading Roof For Water Proofing Treatment With Water Proffing Compound: Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) 26 Gola:- Providing Gola 75Mm X 75Mm In Cement Concrete 1:2:4(1 Cement: 2 Coarse Sand: 4 Stone Aggregate 10 Mm And Down Gauge) Including Finished With Cement Mortar 1:3(1 Cement: 2 Fine Sand) As Per Standard Design. 27 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: New Work (Two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. 28 Inernal Finishing: Distempering With Dry Distemper Of Approved Brand Shade ( Two Or More Coats ) Of Required Shade New Work , Over And Including Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 29 Exterior Finishing: Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 30 Painting On Doors, Windows & Ramp Raling :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). 31 Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 32 For Rain Water-P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 33 For Rain Water-P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110Mm Dia 34 Pipe Clip 110 Mm Dia 35 Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300Mm Confirming To Code Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). 36 Part B Electrical Work 37 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Short Point (Up To 3 Mtr.) 39 Medium Point (Up To 6 Mtr) 40 Long Point (Up To 10 Mtr) 41 Fan Point 42 Short Point (Up To 3 Mtr.) 43 Medium Point (Up To 6 Mtr) 44 Long Point (Up To 10 Mtr) 45 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsron Board 46 S&F Following Sizes (Dia.) Of Isi Marked ( Is:9537 P - Ii ) Rigid Steel Conduit With Wall Thickness According To Is Specified Along With Isi Marked (Is:14768 P-Ii 2003) Accessories In Recessed Using Saddles, Clamps, Fasteners, Pvc Bushes, Check Nuts, As Required Including Cutting Jhiris In The Wall And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 25 Mm 47 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 48 1 X 1.5 Sq. Mm 49 2 X 1.5 Sq. Mm 50 2 X 2.5 Sq. Mm 51 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6 A To 32 A Rating 52 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Metal Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 8 Way (8+2) 53 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Minimum Lumen Output 1300 Lm 54 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity >99.7 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6.0 Sq. Mm 4 Core 55 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 3 Star Rated (Service Value >=5.0 To 56 Providing & Fixing Of Isi Marked (Is:371) 6 Amp Surface Type 3 Pin Ceiling Rose With Cm/L No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screws Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 57 Providing & Fixing Of Isi Marked (Is:1258) Batten/Angle Lamp Holder With Cm/L No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 59 P & F 1.2 Mm Thick G. I. / M .S. Sheet Boxes Duly Finished With Two Coats Of Red Oxide And With Earthing Terminal Of Following Sizes (Nominal Size) In Recessed/Surface As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 175Mm X 100Mm X 60Mm 60 P & F Paper Phenolic Resin Bonded Laminates Confirming To Is : 2036 - 1995 For Boxes/ Frames Including Making Holes For Switches Etc, With Brass Screws, Washers/ Zinc Plated Nut And Bolts As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 3.0 Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
7.
Public Administrative Department #11267040 Price Bid
Tender for Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Un-Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 4 Sqmm , Providing And Fixing Stainless Steel Name Plate Of Size 6×8 Sq Inch Made Of 20 Gauge Sheet Including Engraved Name Of Area Representative Duly Painted Along With Ss Clamp Nut Bolt Etc As Required. , Fabrication, Supplying And Fixing Class B Galvanised Single Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipe With Tightening Bolts Complete As Required , Fabrication, Supplying And Fixing Class B Galvanised Double Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipes With Tightening Bolts Complete As Required. , Providing And Laying In Position M25 Grade Reinforced Cement Concrete Foundation Of Size 450 Mm(L) X 450 Mm Wide And 1000 Mm Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Rewinforcement Of Cold Twisted Bars Of 12 Mm Dia -960Mm Long (Approx.) - 8 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 1400 Mm (Approx.) - 6 Nos. (With 150 Mm Spacing) As Required With Supplying And Positioning Of 4 Nos Foundation Bolts Of Size 16 Mm Dia And 600 Mm Long, J Type I/C 2 Nos Template Anchor Plates Of Size 225 Mm X 225Mm X 3 Mm And Providing 63 Mm Dwc Hdpe Pipe For Cable Entry & Exit As Required For 5Mtr Pole , Fabrication, Supply & Erection Of 5.0 Mtr Height, Minimum 3 Mm Thick, Bottom Dia Of 130Mm & Top Dia Of 70Mm, Base Plate Of Size 225 X 225 X 12 Mm Thick Flange Mounted Hot Dip Galvanized Octagonal Pole Made From Ht Steel Plate, Window With Flash Cover With Full Vertical Window Cover At Appropriate Height From The Base Plate On Existing Cement Concrete Pedestal As Required. L/C Supplying And Fixing Of 6 Mm Thick Laminated Mounted Sheet Inside The Window And L/C Providing And Welding 3 Nos. Gi Strips 4 Mm Thick Of Suitable Length And Having Suitable Size Tapped Holes As Reqd, Terminal Block Suitable For 25 Sq Mm Conductor - 4 Nos. & Shorting Links On Din Channel L/C Providing And Fixing Din Channel Of Suitable Length, 6 Amp. Spmcb C Curve Characteristics, Earth Stud, Cable Support Clamp Suitable For Upto 4X25 Sqmm Cable. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is Code Etc As Required , Supply And Fixing Of 32Mm Dia X 1 Meter Long G.I. Pipe (Medium Class) Bracket For Mounting Of Fluorescent/Hpmv/Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos 25Mm X 6Mm Flat Iron Clamps With Nuts, Bolts And Washer , Painting The Flat Iron With Primer And Finish Paint Etc. As Reqd. , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection,Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 45 Watt
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
8.
Tourism #11266721 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
9.
Housing Urban and Rular Development #11229363 AOC
Misc. Repairs And Other Civil Works Of Tiles, Doors, Windows,Wooden Flooring, Shed And Internal And External Painting In C.M. Bunglow Civil Line Nagpur.(Only For Society).-= 1 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand 2 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. 4 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 1190 to 1202 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring 5 Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete. 6 Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 7 Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 8 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 9 ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. 10 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 11 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 12 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 14 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete 15 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete.b) Granite 16 Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. 17 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 18 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc.as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge. 19 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 20 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 21 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. 22 Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed includingthrowing the unserviceable materials out side etc. complete. 23 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 24 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 25 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 26 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 27 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 28 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 29 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 30 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 31 Providing and fixing C.P. BIB cock with wall flange jaquar or equivalent make continental (CAT.NO. CON-047) including necessary sockets/ union nut etc. complete. 32 Providing and fixing C.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental (CAT.NO. CON-059) including necessary sockets/union nut etc. complete. 33 Providing and fixing C.P. pillar cock long neck with aerator jaquar or equivalent make continental (CAT.NO. CON -021) including necessary sockets/union nut etc. complete. 34 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 35 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 36 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 37 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets & necessary fittings and tested as per municipal requirement etc. complete. 38 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres 39 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 40 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. 41 Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover etc. complete. 42 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.NO. CON-273 UPR) including necessary sockets/union nut etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 45 Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 46 Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. 5 km leadloading unloading 47 Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. 48 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) 49 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 kg) 50 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kg/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 51 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 52 Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 mm thick and 75 mm wide with panel insert of 12 mm thick particle Board with one approved coloured Laminated Face on one side 1.5 mm thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 53 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). 54 Providing and fixing C.P. 2 Way BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. 55 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 57 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 58 Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete 59 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessaryscrew, making proper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-chareg. 60 ProvidingHydrulic door closer .... 61 ProvidingSuper Jet Spry with flange 2 in 1 faucet 1.50 mtr long. 62 Providing Skilled plumber with tools as per direction of Engineer Incharge. 63 Providing skilled carpentor with tools as per direction of Engineer Incharge 64 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface and including scraping etc. complete. 65 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 66 Providing and applying single coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 67 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 68 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 69 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 70 Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete 71 Providing curtain rod dropping with channel MAC brand of superiar quaility including all required material labour etc complete. as directed by engineer incharge......... 72 Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and maketo door shutter including removing existing the same inoriginal position making prope radjustment for smooth operation etc. complete as per sample approved by Engineer incharge. 73 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and maketo door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. 74 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and maketo door/window shutter including removing existing the same inoriginal position making proper adjustment for smooth operationetc.complete as per sample approved by Engineer in-charge. 75 ProvidingHandle 150 mm Chromium plated (Rounded shape). 76 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 77 Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. 78 Providing & fixing Decorative wall paper superior quality including adhesive to fix at wall etc complete. as directed by engineer incharge......... 79 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 80 Providing & fixing Mica laminate as per ISI 0.1 mm thick etc complete...... 81 Providing & fixing 19 mm plywood 710 bwp full red core with report etc complete...... 82 Providing & fixing 12 mm plywood 710 bwp full red core with report etc complete...... 83 Providing & fixing teak wood batterns 50x25 mm etc complete...... 84 Providing & fixing plain glass 6 mmetc complete...... 85 Providing & fixing teak wood batterns 70x45 mm etc complete...... 86 Providing & fixing door stopper etc complete...... 87 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 88 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 89 Providing and Laying wearing laminate wooden or eqiuvalent flooring 8 mm thick in attractive strips for conference hall. 90 Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kg/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 91 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 92 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with allnecessaryfixturesandfittingetc.complete.(SampletobefinalbyEngineerIn-charge prior execution of work) 93 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 94 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 95 Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 96 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 97 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. 98 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. 99 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 100 BASIC TEST OF CEMENT :-Standerd Consistancy Fineness, Specific Graviti, Setting Time (Initial & final, Compressive Strength, Soundness. 101 BASIC TEST OF BRICK :-Water Absorption, (Set of 5 Brick), Comoressive Strength (Set of 5 Blocks), Efflorescence (Set of 5 Bricks) 102 CERAMIC TILES/ VITRIFIED TILES :- Water Absorption, Modules of Rapture (Set of 6 Tiles) 103 BASIC TEST OF C. C. TILES. :-Flexural test(Set of 6 tiles) Water Absorption,(Set of 6 tiles) Resistance to wear(Set of 6 tiles). 104 BASIC TEST OF Fine Aggregate Fineness Modulus (Sieve Analysis) silt and cley content..... 105 BASIC TEST OF Concrete Paving Block :- Compressive strength, Water Absorption, (Set of 8 Blocks ) 106 BASIC TEST OF STONE / RUBBLE/ Crushing Value/Compressive strengh, Water 107 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction materials for whichroyalty is necessary.(Royalty charges will be paid to contractor after sumbitting valid documents of revenue authority)Royalty for naturalSand (Royalty + Surcharges 2% & Distt. mineral foundation cess 10%)
Contract Date: Jun 04, 2026 Contract Value : 15.18 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
10.
Textiles #11228400 Price Bid
Tender for Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Dismantling Cement Asbestos Celotex Or Other Ceiling Or Partition Hard Broad Wall Including Stacking Of Serviceable Materials And Disposal Of Unserviceable Materials Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead A.Of Area 3 Sq.M. And Below , Clearing Debris Includes Civil/Elect Items From Site And Disposing The Debris 10Km Away From The Site Including Loading Unloading Labour Charges And Clearing The Site Good For Work Etc.Complete , Providing And Fixing Of Double Leaf Door With Cnc Cutting As Per Design Made In -20Mm Plywood With 3Mm Thick Veneer Using Ss Pvd Coated T Patties And Pu Paint And Melamine Polish Using Ply Of Century Or Equivalent Brand Including All Necessary Hettic Soft Closing Fittings Etc. Complete , Providing And Fixing Of Single Leaf Door Made In -12Mm Plywood With 3Mm Thick Veneer Using Ss Pvd Coated T Patties And Pu Paint And Melamine Polish Using Ply Of Century Or Equivalent Brand Including All Necessary Fittings Etc. Complete , Providing And Fixing Of Partition Board Paneling With Aluminium Frame Work Of Section Size 50Mmx25mm Vertically And Horizontally At 600Mm C/C With 12Mm Thick Plywood, Top With 3Mm Thick Veneer Sheet And Using Ss Pvd Coated T Patties And Pu Paint And Melamine Polish For Smooth Finish, Using Century Ply Or Equivalent Brand For Panelling And Fixing With Necessary Screwing And Supports Etc.Complete , Supplying Of Fire Sensor / Smoke Detector-10Nos / Existing Sprinker Replacement / Relocation / Wiring / Hooter Panel Etc , Providing And Fixing Vitrified Double Glazed Finished Of 10Mm Thick Tiles Of Size 8Ft X 4Ft In Floor, Treads Or Riser Of Steps, Landing On 25Mm Thick Bed Of Cement Mortar 1:3 And Jointed With Cement Slurry Filling Tile Joints With Matching Pigment And Make Of Of Kajariya/ Simpolo Of Any Colour As Specfied By Engineer In Charge Etc.Complete. , Proving And Fixing False Ceiling Of 1.5Mm Thick Aluminium Powder / Anodised / Painted / Coated -Profiled Panels Mounted On Ms/ Gi Frames For Support And Painted / Powder Coated Chanels / With Provision For Ac Trap, Door And Light Fixing,As Per Engineer Incharge Etc.Complete , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) C. In Beams, Suspended Floors, Roofs Having Slope Upto 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases Upto Floor Five Level , Supplying And Fixing Of Window / Roller Blind Made In100% Polyster Fabric Design Plain And Colour As Per Engineer In Charge , Providing And Fixing Of 3+2+1+1 Seater Sofa Set Made In Sal Wood Frame With High Density Foam As Design As Per Drawing And Engineer In Charge , Supplying And Fixing Of Designer Artifacts Showpiece Design As Per Drawing And Engineer In Charge , Supplying And Fixing Of Nylon Based Carpet 5 Mm Thickness With Backing Design As Per Drawing And Engineer In Charge , Supply And Placing In Position Artificial Planters With Ceramic Pots Etc Complete As Shown In The Drawing And As Directed Engineer Incharge. , Design & Supply Of Signages Made From 2Mm Thick External Grade Acp Sheet Of Size (Wall Mounted) With High Grade Plotter-Cut/Cnc-Cut Vinyl & Auto-Glow Vinyl Pasted Lacquering Of Letters/Pictogram On Front Side Of The Plate, Of Varying Colours As Per Detail Drawing And Engineer In Charge. , Supplying And Fixing Of Pa - Speaker Wiring With 6Nos Ceiling Mount Speaker To Be Connected To Existing Pa System Including Cabling ,Fittings Accessceries And Necessary Supports Etc Complete. , Supplying And Fixing Of Light Fittings Of Make -Hybac /Haffle /Phillips / Panasonic/ Anchor/ Wipro / - 7W/9W/12W/20W - Panel / Cob , Supplying And Fixing Of Decorative Lights Including Wiring ,Fittings Accessceries And Necessary Supports And Installation Charges Etc Complete , Pvc Insulated Copper Wires 10 Pair 0.5 Sq.Mm Copper Conductor Frls Pvc Insulated Unarmoured Indoor Type Telephone Copper Cable , Supplying Of 20 Mm Dia Isi Marked Steel Condict With Wall Thickness 1.6 Mm , Supplying Input/Output Rj-45 Connector-Cat B , Supplying Sp Mcb, 6 A To 32 A, 10 Ka, B Series, Cat A , Supplying Of Perforted Gi Cable Tray Cross Members 1000 Mm Width X 75 Mm Depth X 2.00 Mm Thick , Supplying Of 12 Watt Cob - Brand Panasonic, Wipro, Philips Etc Complete , Supplying Of 7 Watt Cob - Brand Panasonic, Wipro, Philips Etc Complete , Supplying Of Strip Light 24O Led - Etc Complete. , Supplying Of Cove Light - Brand Etc Complete. , Electrical Labour Fitting Charges Which Includes Laying Of Cables/ Condut Pipes For Fixing Of All Fixtures And Fittings Like Light/Mcb/Schindlers Etc Complete. , Supplying Of Cendilier Designer Type For Passgae Area As Per The Design Selected , Unarmoured Pvc/Xlpe 1100 V Cable 2 Core 2.5 Sq.Mm Copper , Armoured Pvc/Xlpe 1100 V Cable 2 Core 2.5 Sq.Mm Copper , Daikin 5.3 Tr High Static Ductable Ac Supply (Model: Fxmq170nve6) , Daikin 3.2 Tr High Static Ductable Ac Supply (Model: Fxmq80pbv36) , Daikin 10Hp Vrv X Odu Unit Supply Model -Rxq10ary6 , Supply Of Refnets , Wired Remote And Receiver Kit , 0.9 Tr Daikin Split Ac Model - , Installation Testing And Commissioning Of Vrv 10Hp Odu Unit. , Installation Testing And Commissioning Of Indoor Unit. (Installation Of Ductable Ac) , Installation Testing And Commissioning Of Indoor Unit.(Installation Of Split Ac) , Supply And Fixing Of Pvc Drain Water Piping With 6Mm Thick Nitrile Rubber Insulation Complete With Fittings (Elbows, Tees, Reducers, U-Traps, Sockets Etc As Required) And Any Other Item Required To Make The System Complete. Nominal Diameters In Mm As Indicated Below. 32 Mm , Supply, Installation, Testing & Commissioning Of Refrigerant Copper Pipe Suitable For Vrv System With R32 Gas & Having Guage Thickness And Inner Dia As Below. Piping Should Be Insulated With Nitrile Rubber Foam Tube Type Sleves And Insulating On Provided Copper Pipes Having 13Mm / 19 Mmthickness, , Threading Rod & Indoor Kit , Supply And Laying With Pvc Conduit, Of 1 Sqmm / 2C, Communication Cable For Vrv Units , Supply & Charging Of Additional Refrigent Gas R 410A (If Required) , Perforated Gi Cable Tray 450 Mm Width X 50 Mm Depth X 2.0 Mm Thick , Supply And Installation Of 24Gi Duct , 13Mm Insulation , Supply And Installation Of Round Diffuser With Damper , Supply And Installation Of Return Grill , Supply And Installation Of Canvas Connection , N Odu Fabrication Work
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
11.
Public Administrative Department #11212847 AOC
Tender for Supplying And Laying Of Following Size C Pvc Pipe In Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is:4985:2000, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (50 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 25 Mm Dia , Fabrication, Supplying, Installation, Testing And Commissioning Of Bollard Light Having Length 750Mm Of Ms Sheet I/C Making Design By Laser Cutting , As Approved By Engineer In Charge And Welding The Same, With 2 Nos. 10 Watt Warm White 2 Feet Long Led Tube Light Fitting And Having Suitable Arrangement To Accommodate 2 Nos. 10 Watt Warm White 2 Feet Long Led Tube Light , Duly Painted With One Coat Of Primer And Two Coat Pu Paint I/C J-Type Foundation Nut Bolt, But Excluding Foundation Complete As Required. , providing and Fixing Hot Press Sheet Moulded Compound (Smc) Fire Retardant (Temp. Resistance Up To 200 C), Ip 55 Weather Proof Pole Box Of Inner Dimension 300X200x105mm (Ns) And Outer Dimension Of 333X233x150 Mm High Dome Complete With Suitable Arrangement For Fixing Of 4 Nos Of 6 To 32 annual periodical maintenance Single Pole Mcb & 63 Amp. Double Pole Isolator (Mcb/Isolator Excluded) With Neutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plate Of Suitable Size With Danger Monogram Property Printed On The Cover Etc As Reqd. , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.(A) Single Pole , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (B) Single Pole And Neutral , Supply Of Following Size Of Pvc Insulated & Pvc Sheathed Copper Conductor 3 Core Submersible Cable Conforming To Is . 694/210 Etc. As Rqd. 3×2.5 Sqmm With Voltage Grade 1100 Volts. , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 10 Sqmm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge. All Kinds Of Soil , Centering And Shuttering With 12Mm Thick Shuttering Plywood Confirming To Is 4990:2011 And Removal Of Form At All Heights. Plywood Will Be Supported On Lock Bars. Suspended Floors, Roofs, Landings, Balconies And Access Platform. Suspended Floors, Roofs, Landings, Balconies And Access Platform. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm
Contract Date: Jun 11, 2026 Contract Value : 61.00 Lakh
Local Bodies No of Bidders 4
12.
Public Administrative Department #11212721 Price Bid
Tender for Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Supply And Fabrication Of Pole Protection System Made Up Of 8 Swg Steel Wire Mesh Of Size 25Mm X 75Mm Rectangular With 50Mmx50mmx6mm Ms Angle Iron For Supporting The Mesh I/C Mv Danger Plate And Grounding The Protection System In Suitable Quality Of cement concrete Etc As Reqd. , Fabrication, Supplying, Installation, Testing, Commissioning Of 12 Metres Semi High Mast System With Its Accessories, Mast Shaft Shall Be In One Section, Hot Dip Galvanized 4Mm Thick(Single Dip) Inside & Out Sides &Sultable For Wind Velocity As Per Is 875 Part3.There Shall Be In Longitudinal Seam Weld Per Section And No Circumferential Weld. It Should Also Included Accessories For Seml High Mast Head Frame,2 Point Suspension System,5 X 2.5 Sqmm Copper Conductor With Steel Wire Rope 5Mm Dia. (7/19 Construction) Single Drum Winch ,Galvanized Lantern Carriage Arrangement Suitable For 4/6 Nos. Flood Light Luminaries Symmetrically And Its Control Gears Boxes And Lighting Finial, The Mast Shall Have Integral Type Manual Tool Mounted At The Base Compartment Of Its Raising And Lowering Operation With Foundation Bolts And Anchor Plate And Control Panel Housing Suitable Reinforced Cement Concrete (1:2:4) Shallow Foundation Of Size 1M(L) X 1M Wide And 2M Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Reinforcement Of Cold Twisted Bars Of 12 Mm Dia -2100Mm Long (Approx.) 16 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia 3700 Mm (Approx.) 13 Nos. (With 150 Mm Spacing) As Required With Positioning Of Foundation Bolts And Providing Dwc Hdpe Pipe For Cable Entry & Exit As Required For The Semi High Mast Considering The Safe Soil Bearing Capacity At Site As 10T/Sqm At 2Mts. Depth With All Material I/C 4 Nos S.P Mcb,1 No. Double Pole 16Amp. Mcb Etc As Reqd. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is. , Providing And Fixing Name Board Made Of Ms Sheet 90X60cm, 1Mm Thick With Frame Of Ms Angle 50X50x6mm, Two Diagonal Braces At The Back Of The Sheet Of Ms Flat 40X6mm, Total Height Of The Board Above Ground Level 2.40M, Length Of Legs Below Ground 0.30M Embedded In Cement Concrete Block 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size) 30X30x45cm Including Excavation And Removal Of Surplus Earth With In 50M Lead, Applying Priming Coat Of Approved Steel Primer, Painting With Synthetic Enamel Paint Of Approved Quality And Lettering With Enamel Paint Of Approved Colour (One Side) As Per Drawing/Direction Of Engineer-In-Charge , Led Flood Light, Powder Coated Pressure Die Cast Aluminum (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip-66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 100W
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
13.
Educational and Research Institute #11209017 AOC
Bids Are invited for Boq Iteam Double Beam Uv Visible Spectrophotometer - Variable Bandwidth 1Nm 2Nm 4Nm 8 Cell Holder , Ph Meter Basic - Range 0 To 14.00 Ph Ph Resolution 0.1 Ph To0.01 Ph Accuracy 0.01Ph Calibration Points Up To 3 Points Ph Buffer Options Usa Ph 4.01 7.00 10.01 Automatic Memory Up To 25 Readingstemperature Compensation Atc , Conductivity Tds Meter - Conductivity Range 0 To 200Mscmbig Screen Large Lcd Display With White Backlight Memory Upto 100 Readings Usb Interface 0.001 Resolution 3 Points Calibration , Uv Transilluminator - Na , Double Distillation Plant - Output 4 Ltr And Hr Cooling Water Consumption Ltr Or Hr 150 Ltr Or Hr Power Rating Kw 6 Kw , Multi Tube Vortex Mixer - Operation Mode Run And Touch Operation Speed Range 500 To 3000Rpm Litude 4Mm Horizontal Swing Timing Function Led Display Maximum Load 4Kg Process Upto 50 S Les At A Time , Orbital Shaker Digital Display - Bushless Motor Speed Range 40 200Rpm Plate Size 250 Into 250 Into 50Mm Maximum Load 2Kg Timing Function Universal Tray Platform Operation Mode 20Mm , Mini Thermostatic Incubator - High Precision Controller, Precise Temperature Control, Over Temperature Alarm,Inner Chamber Surround Heating, Uniform And Stable Temperature,Compact Design, Light Weight, Small Volume Energy Saving And Power Saving, Equipped With Handle,Easy To Carry & Clean, Mirror Finishing Stainless Steel Inner Design,Unique Geometric Cavity Clean Design. , Multiposition Magnetic Stirrer - Heating And Stirring Facility Asynchronous Control Lcd Display Brushless Motor Ss304 Stainless Steel Plate Corrosion Resistance No Of Stirring Point 4 Into 500Ml Rpm 50 1200 Time Setting Function Plate Temp 120C , Water Bath - 2 Hole 4 Hole 6 Hole 8 Hole Temperature Range Rt 5C100c Time Function Ss304 Stainless Steel Tank Human Body Movement Sensor,Automatic Temperature Control Program Ultra Small Empty Dry Burning Sensor , Digital Ultrasonic Cleaner - Temperature Range Rt 7 C To 80 C Blue Led Display Normal And Soft Power Control For The Cleaning Spots Degas Function Available Time Setting Tank Ss304 , Portable Do Meter - Polarographic Dissolved Oxygen Electrode Lcd Display With White Back Light Long Battery Life 1 Or 2 Points Calibration Auto Power Off Memory Stores Or Recalls Up To 100 Data Sets Usb Communication Interface Carrying Case Easy To Carry For Field Use , Four Probe Method Apparatus - Four Probe Arrangement For Ge Crystal S Le Ge Crystal Mounted Oven Upto 300C Thermometer 0 To 300C Constant Current Power Supply Digital Accuracy 1Percent Load Regulation 0.03 For No Load To Full Load Digital 200Mv And 20Ma , Hall S Effect Apparatus - Consists Of 7 Point 5 Kg Electromagnet Power Supply For Electromagnet 0 To 100V 6A Mp Germanium Crystal Mounted And Digital Constant Current Power Supply With Two Meters 0 200Mv And 0 20Ma Halls Voltage And Crystal Current Gauss Meter Digital 0 20K Gauss With Hall Probe And Two Wooden Stands , Fume Hood - Fume Hood Fume Hood Is An Enclosure Which Is Used To Remove Fumes And Air Borne Parti Cles At The Contaminate On Source It Is A Kind Of Fume Venti Lati On System Which Prime Work Is To Remove Smoke Dust Mist And Chemical Fumes And Restrict Their Entry Into Laboratory Environment A Laboratory Fume Hood Comprises Of Metallic Sheet Enclosure Steel Or Marble Stone Work Bench Service Fixture And Electrical Points For Fume Exhaust Heavy Duty Blowers Are Fi Tt Ed And Remotely Connected To The Duct Chemical Fume Hood Fume Cupboard And Fume Closet Are Similar Names Of Fume Hood Outer Body Made Of Ms Powder Coated Or Stainless Steel 304 Grade For Suction On In Fume Hood We Provide Centrifugal Blower Assemble Made Of Direct Drive Motor Fitted With Fluorescent Light And A Gas Cock For Gas And Air Supply Power 220 230Volts Ac Supply Working Table Size 3 Inch Into 2 Inch Into 2 Inch Whole Cabinet Made Of Cold Rolled Steel Duly Powder Coated And Inner Frp , S Le Vials 30Ml - Each Pkt Containing 100 Units , S Le Vials 50Ml - 1Pkt, Respectively Each Pkt Containing 100 Units , High Temperature Controlled Furnace - High Temp Controller Furnace 1200 Degree 9 Into 4 Into 4 Microprocessor Pid Digital Temp Indicator Cum Controller Instead Of Energy Regular Pyrometer , Micro Oven - 18 Into 18 Into 18 Temp Upto 250 Deg Double Walled Inner Chamber Of Andoized Stainless Steel Digital Temp Indicator Cup Controller Pid Temp Digital , Weighing Balance - Kab5l 220G 0.1Mg Internal Calibration Lcd Display Emfc Technology Underhook Piece Counting , Micropipettes 1Ml - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 10 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 20 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 100 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Micropipette 200 - Quickpip Fixed Volume Micropipette With Fully Autoclavable Calibration,Accuracy As Per Iso 8655 Digital Display Stream Lined Tip Ejector Two Step Operation , Laboratory Autoclave Vertical - Vertical Double Wall 98 Ltr Load 5Kw Size 450Mm Into 600Mm Inner And Outer Ss Radial Lock Digital Temp Indicator Fitted With Vaccum Breaker As A Safety Device 220 Volt Ac Supply , Multimeter - A Multimeter Range Instrument For Measure Of Voltage Current And Resistance Moving Coil Meter Having Red Pointers Over Two Colour Scale Complete With Test Leads Probez And Internal Battery , Current Ammeter - Dc Mounted In Beautiful Bakelite Acrylic Stand With Accuracy 2.0Percent F S D With Lock Type Terminal Packed In Card Box All Common Ranges Available , High Speed Centrifuge Remi Rpm 17300 In R 24 - Stepless Speed Regulator With Zero Speed Indicator Digital Speed Indicator.Dynamic Brake 0 To 99 Minutes Digital Count Down Timer Imbalance Detector With Cutoff Safety Lid Interlock , Celestron Handheld Digital Microscope Pro - Magnification Range 20 Into To 200 Into Ring Illuminator 8 Led Adjustable Cmos Sensor In Lieu Of Eyepiece Total Quantity : 36
Contract Date: Ref. Documents Contract Value : 63.08 Lakh
Government Departments No of Bidders 10
14.
Defence #11206901 AOC
Tender For Provision Of Work Services For Sdr Facility In Abr Lab At 9Brd Afs Pune Under Ge Af Lohegaon - Taking down the existing surface batten type point wiring of aluminium/Copper for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. 2 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 3 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board )ISI Marked (IS:14772) for housing switches / sockets all a specified and directed 4 (a) One Fan point/ light point controlled by one switch. 5 (b) One 3 pin socket 5 A on same board. 6 (c) One 3 pin socket 5 A on independent board. 7 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board)ISI marked (IS 14782) for housingone 15 A Switch / socketsall a specified and directed 8 M/L for sub main wiring with two runs of single core 4.0 Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 4 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cablefor continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified.(Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length) 9 M/L for sub main wiring with two runs of single core 6.0Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length ) 10 Supply and fix switch piano flush type 5 Amp one way, ISI Marked 11 Supply and fix Socket out let 2in 1, 5 pin 5 Amp ISI Marked 12 Supply and fix switch socket combination 5 / 16 A, 5 in 1, flush type,ISI Marked 13 S/F Fan Regulator electronic step type 100 W,ISI Marked complete as directed 14 Supply and fix ceiling rose surface type bakelite / PVCthree terminal 65 x 50mm. ISI Marked 15 Taking down existing VTPN DB grouted in wall and S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 16 Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge. 17 Supply and fix MCB SPN B Curve 240 V, 32 Amps. complete all as directed at site. 18 Supply and fix MCB SP B Curve 240 V ,6 to 32 Amps complete all as directed at site. 19 M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plateNo. 3 of SSR Part I of 1991 & testing complete including 15mm dialight grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GIwatering pipe etc. 20 Supply and fixing in replacement of double pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed 21 S&F of CEE Panel mounted receptacles 16 A, 3 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 22 S&F of CEE Panel mounted receptacles 16 A, 5 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 23 S&F of CEE plug 16 A, 3 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 24 S&F of CEE plug 16 A, 5 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 25 S&F of Sub main wiringwith 4 X 6 sqmm single core cable FRLSH PVCinsulated unsheathed of copper multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length). 26 S&F of Sub main wiringwith 4 X 10 sqmm single core cable PVCinsulated unsheathed of copper FRLSH multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length). 27 Taking down carefuly copper strip of Size upto 32x6mm including pocelain/epoxy insulator, storing in safe custody for reuse and refixing the taken down copper strip as directed at site including supply and Fix of new epoxy insulator at a gap of 1 meter and brazing of copper strip with double nut and bolt with overlap of 3 cm complete all as directed by Engr-In-Charge. 28 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed. 29 Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site. 30 Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site. 31 M&L for making hole in Brick masonary / Stone masonary wall of any thickness and height of round shape and suitable for exhaust fan of 380mm dia and making good disturbed wall and painting distubed area as original complete all as directed. 32 Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louver complete all as specified and directed. 33 1. Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2TR having dual rotor inverter compressor, 100% copper IDU and ODU, installation kit with extra copper piping, connection electric cord, drain water pipe as per site requirement and incl MS Stand for outdoor unit fixng and core cutting in stone masonary wall if required for passing of refrigerant piping and cables etc and making good disturbed surfaces matching to existingcomplete all as specified and directed by Engr-In-Charge 34 Supply and fixing of voltage stabilizer for automatic operationsingle phase naturally air cooled indoor typefor input variationbetween 170V to 280V with outputVoltage 230v with accuracy +/-2.5% and of capacity 5 KVA completeall as directed. 35 Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. 36 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 300 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 37 S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 38 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 35 Sqmm 3.5 Core laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix on wall etc all as specified and directed. 39 Supply install, test and commissioning of Powder coated LTpanel cubical Indoor type floor standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomerand outgoing feeders .The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhave bottom frame & dimension as required for panel & stand shall be made out of equal angle iron of size 50mm x 50mm x 6mm height 600mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 tank process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including provision of heat shrink sleeve on each cable core within panel, lugs, nut bolts, washers etc complete all as specified and 40 a) Copper bus bar 500 Amps for 4 pole-01 SETb) MCCB FP 320 Amps415 Volt 50 KA,Ics =100% Icu WITH thermal and magnetic setting type - 1 Nosc) MCCB FP 100 Amps - 415 Volt 16 KA,Ics =100% Icu- 5 Nos f) RYB Indicators - 1 Set and g)Digital 3 Phase Amp Meter and Voltmeter with selector switch - 1 SetNote - (i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication. 41 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 25 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 42 Supply and fix Voltage stablizer for automatic operation, three phase , naturally oil cooled, inddoor type anddesigned for input variation between 300V to 480 V with accuracy + 2.5 % , IP55 Protection, 50 Hz, Unbalance type, copper wounded, matallic body duly powder coated, liftinghooks, digital display, relay controlled for smooth and silent operation with first filling of transformer oil upto specified level , with zero distortion waveform, sesitivity +/- 1%, overall Efficiency more than 95 % digital multifunction meterand speed of correction 8 volts per second and of capacity 30 KVA complete all as specified and directedNote: (a) Stablizer shall be free from hunting during automatic operation and No load losses shall not be more than 5% of rated output current.(b) Protection: (i) Overload short circuit protection at input end by MCCB 4 pole of suitable size as per recommendation of OEM - 01 Nos (ii) High / low voltage cutoff(iii) By pass arrangement - providing 01 No 4 pole on load changeover switch of suitable rating (iv) single phase sequence change protection.(c) Acceptance Test :- Testing of servo voltage stabilizer should be carried out as per BIS 9815 (Part-I) in OEM factory in the presence of rep of Accepting Officer and contractor/his rep. Contractor shall give 45 days in advance intimation with respect of date of testing. The following testing shall be carried out:(i) Physical Examination (ii) Insulation resistance (iii) High voltage test (iv) Leakage current test (v) Output voltage (vi) No load current (vii) Measurement of No load loss induced voltage testNote : Before make and specification approval type test report of OEM as per BIS 9815 Part - I should be produced by contractor for the specified capacity / next higher capacity of any voltage range from Govt Lab / NABL accredited lab. 43 Supply, installation,Boring, erection, testing and commissioningof Copper bonded(150 micron) MS solid rod electrode of dia 17.2 mm and 6 mtr long with high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Earthing Electrode shall bemade by embedding copper bonded MS Rod electrode in 100mm dia macronite conductive concrete made by mixing high purity conductive granularmixed with cement in the ratio2:1 (2 part of high purity electriclly conductive granular and 1 part cement and one litre of water per kg of mix ). The earthing electrode shall be augured inbore hole of dia not less than 100mm and6 Mtr depth. The conductive material shall confirm to BIS: 3043-2018. The rod shall be embedded in conductive concrete at factory with concrete having resistivity 0.040 Ohm-m. The top edge of the electrode shall comprise of plate provided with 04 holes for connections of the earthing strip,including brass nut bolts for connections of the strip the copper strip shall be duly brazed/welded with connection terminal of earthing rod, including FRP square chamber cover 300mm x 300mm x 250mm with top cover complete all as specified.All the material such as copperbonded MS rod and concrete mix shall be Ph nuetral, chemicaly inert and non corrosive complete all as specified and directed by Engr-In-Charge.i) The contractor shall submit type test report issued by the CPRI for high purity, electrically conductive earthings , confirms to rated short time withstand current20 KA per sec. ii) The factory made electrode shall be tested at factory and test report shall be submitted.iii) Factory testing of individual earthing shall be carried out in presence of rep of accepting officer and report shall be submitted.iv) The contractor shall obtain make approval for high purity electrically conductive granular duly by submitting certificates conforming to resistivity is 0.001 ohms by granular manufacturer.v) On installation of earthings at site, 04 to 05 Nos earthings shall be connected in grid to achieve less then 1 ohm resistance of grid, If desired resistance is not achived the contractor shall redo the same without any extra cost. vi) The contractor shall submit certificate issued by OEM of earthing electrode starting that The desired maintenance free earthing resistance less than 1 ohm. The year will be maintained for not less than 25 years. 44 M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.Note:-(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 45 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified.Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 46 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal block cover box made out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer. 47 S & F copper earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc.and connecting with earthing test point oras required complete all as directed. Note: Earth work required shall be deemed to be included in quoted rate, nothing extra shall be paid on this account. 48 Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc. 49 Soft/loose soil 50 Hard/dense soil 51 Soft/disintegrated rock 52 Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil. 53 Removing the surplus soil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level. 54 M&L for Cutting the existing road precisely for laying of cable crossing pipe and making good the distubed surface of road as per original after laying of pipe and removal of debries complete all as directed.Note: The cost of making good is deemed to beincluded in quoted rate. 55 Supply and fixof MCCB FP 63 AmpsFixed type with breaking capacity16 KA with Sheet metal enclosure of 2 mm thick CRCA sheet single door with provision opening for incomming and outgoing cable/ submain including connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
Contract Date: Feb 04, 2026 Contract Value : 35.23 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
15.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
16.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
17.
Public Administrative Department #11181011 Price Bid
Tender for Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Supplying And Drawing Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3X1.5 Sqmm , Providing And Laying In Position M25 Grade Reinforced Cement Concrete Foundation Of Size 450 Mm(L) X 450 Mm Wide And 1000 Mm Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Reinforcement Of Cold Twisted Bars Of 12 Mm Dia -960 Mm Long (Approx.) - 8 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 1400 Mm (Approx.) - 6 Nos. (With 150 Mm Spacing) As Required With Supplying And Positioning Of 4 Nos Foundation Bolts Of Size 16Mm Dia And 600 Mm Long J Type I/C 2 Nos. Template Anchor Plates Of Size 225X225x3 Mm And Providing Dwc Hdpe For Cable Entry & Exit As Required For 3 M And 5 Mtr Pole. , Fabrication, Supply & Erection Of 5.0 Mtr Height, Minimum 3 Mm Thick, Bottom Dia Of 130Mm & Top Dia Of 70Mm, Base Plate Of Size 225 X 225 X 12 Mm Thick Flange Mounted Hot Dip Galvanized Octagonal Pole Made From Ht Steel Plate, Window With Flash Cover With Full Vertical Window Cover At Appropriate Height From The Base Plate On Existing Cement Concrete Pedestal As Required. L/C Supplying And Fixing Of 6 Mm Thick Laminated Mounted Sheet Inside The Window And L/C Providing And Welding 3 Nos. Gi Strips 4 Mm Thick Of Suitable Length And Having Suitable Size Tapped Holes As Reqd, Terminal Block Suitable For 25 Sq Mm Conductor - 4 Nos. & Shorting Links On Din Channel L/C Providing And Fixing Din Channel Of Suitable Length, 6 Amp. Spmcb C Curve Characteristics, Earth Stud, Cable Support Clamp Suitable For Upto 4X25 Sqmm Cable. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is Code Etc As Required , Fabrication Supplyiing And Fixing B-Class Galvanised Single Overhang Arm Bracket Made Out Of 250 Mm Long Galvanized Top Tube With Cap 1000Mm Long 32 Mm Dia Galvanized Pipe With Tightening Bolts Complete As Reqd. , Fabrication Supplyiing And Fixing B-Class Galvanised Double Overhang Arm Bracket Made Out Of 250 Mm Long Galvanized Top Tube With Cap 1000Mm Long 32 Mm Dia Galvanized Pipe With Tightening Bolts Complete As Reqd. , Fabrication,Supplying,Installation,Testing,Commissioning Of 12 Mts.High Mast System With Its Accessories ,Mast Shaft Shall Be In One Section , Hot Dip Galvanized 4Mm Thick (Single Dip ) Inside And Out Sides And Suitable For Wind Velocity As Per Is 875 Part3 .There Shall Be In Longitudinal Seam Weld Per Section And No Circufrential Weld. It Should Also Included Accessories For High Mast Head Frame ,2 Point Suspension System With Steel Wire Rope 5Mm Dia. (7/19Construction) Single Drum Winch ,Galvanized Lantern Carriage Arrangement Suitable For 4/6 Nos. Flood Light Luminaries Luminaries Symmitrically And Its Control Gears Boxes And Lighting Finial ,The Mast Shall Have Integral Type Manual Tool Mounted At The Base Compartment Of Its Raising And Lowering Operation With Foundation Bolts And Anchor Plate And Control Panel Housing Suitable Reinforced Cement Concrete (1:2:4) Shallow Foundation Of Size 1M(L)X1m (W)X2m Deep I/C Excavation Of Earth I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Rewinforcement Of Cold Twisted Bars Of 12 Mm Dia -2100 Mm Long (Approx.) - 16 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 3700 Mm (Approx.) - 13 Nos. (With 150 Mm Spacing) As Required With Positioning Of 4 Nos Foundation Bolts And Providing Dwc Hdpe Pipe For Cable Entry & Exit As Required For High Mast Considering The Safe Soil Bearing Capacity At Site As 10T/Sqm At 2Mts. Depth With All Material I/C,4Nos S.P Mcb,63Amp.Dpisolator Etc As Reqd. Logo/Name Of Manufacturer Shall Be Embossed On The Pole. Galvanized As Per Relevant Is. , Supply And Fabrication Of Pole Protection System Made Up 8 Swg Steel Wire Mesh Of Size 25 Mm X 75 Mm Rectanglar With 50 Mm X50 Mmx6mm Ms Angle Iron For Supporting The Mesh I/C Mv Danger Plate And Grounding The Protection System In Suitable Quality Of cement concrete Etc. , Providing And Fiving Name Board Made Of Ms Sheet 90X60cm, 1Mm Thick With Frame Of Ms Angle 50X50x6mm, Two Diagonal Braces At The Back Of The Sheet Of Ms Flat 40X6mm, Total Height Of The Board Above Ground Level 2.40M, Length Of Legs Below Ground 0.30M Embedded In Cement Concrete Block 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size) 30X30x45cm Including Excavation And Removal Of Surplus Earth With In 50M Lead, Applying Priming Coat Of Approved Steel Primer, Painting With Synthetic Enamel Paint Of Approved Quality And Lettering With Enamel Paint Of Approved Colour (One Side) As Per Drawing/Direction Of Engineer-In-Charge , Providing And Fixing Of Stainless Steel Name Plate Of Size 6X8 Sq Inch Made Of 20 Gauge Sheet Including Engraved Name Of Area Representative Duly Painted Along With Ss Clamp Nut Bolt Etc As Required. , Supply Of Xlpe Insulated,Pvc Sheathed Al.Conductor Armoured Cable 1.1Kv Grade Conforming To Is 7098/1988 Of Following Sizes (A) 2 X6 Sqmm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Metres In Width, And Lift Upto 1.5 Metres, Including Getting Outthe Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Metres , Providing And Laying In Position Cement Concrete Of Specific Grade Excluding The Cost Of Centering And Shuttering-All Work Up To Plinth Level:1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources. , Supplying And Fixing Of Light Class G.I. Pipe Of 50 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitary) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All 51 Delhi Schedule Of Rates (E&M)-2025 Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 45 Watt , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, 54 Delhi Schedule Of Rates (E&M)-2025 Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm (Standard Deviation Colour Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output. Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 100W
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
18.
Public Administrative Department #11181010 Price Bid
Tender for Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 5 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:3:6 (1 Cement : 3Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 10 Qmm , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection,Emiemc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).72 Watt , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection,Emiemc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).100 Watt , Led Flood Light, Powder Coated Pressure Die Cast Aluminum (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip-66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg120deg As Per The Application And The Project Requirement Deg., Suitable Tilt Able Fitting, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 100W , Providing And Laying In Position M25 Grade Reinforced Cement Concrete Foundation Of Size 600 Mm(L) X 600 Mm Wide And 1200 Mm Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Rewinforcement Of Cold Twisted Bars Of 12 Mm Dia -1160Mm Long (Approx.) - 8 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 1600 Mm (Approx.) - 8 Nos. (With 150 Mm Spacing) As Required With Supplying And Positioning Of 4 Nos Foundation Bolts Of Size 20 Mm Dia And 700/750 Mm Long, J Type I/C 2 Nos Template Anchor Plates Of Size 225 Mm X 225Mm X 3 Mm And Providing 63 Mm Dwc Hdpe Pipe For Cable Entry & Exit As Required For 7Mtr And 8 Mtr Pole , Fabrication, Supply & Erection Of 8.0 Mtr Height, Minimum 3 Mm Thick, Bottom Dia Of 130Mm & Top Dia Of 70Mm, Base Plate Of Size 225 X 225 X 12 Mm Thick Flange Mounted Hot Dip Galvanized Octagonal Pole Made From Ht Steel Plate, Window With Flash Cover With Full Vertical Window Cover At Appropriate Height From The Base Plate On Existing Cement Concrete Pedestal As Required. L/C Supplying And Fixing Of 6 Mm Thick Laminated Mounted Sheet Inside The Window And L/C Providing And Welding 3 Nos. Gi Strips 4 Mm Thick Of Suitable Length And Having Suitable Size Tapped Holes As Reqd, Terminal Block Suitable For 25 Sq Mm Conductor - 4 Nos. & Shorting Links On Din Channel L/C Providing And Fixing Din Channel Of Suitable Length, 6 Amp. Spmcb C Curve Characteristics, Earth Stud, Cable Support Clamp Suitable For Upto 4X25 Sqmm Cable. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is Code Etc As Required , Supply Installation Testing and Commissioning of 25 Watt Led Ip65 Post Top Fitting Made Of Die Cast Aluminium Spigot Spun Aluminium Powder Coated Top Cover And Clear Acrylic Diffuser With High Voltage Protection Low Power Led'S Connected In Series And Parallel Combination With Better Heat Sink Arrangement Input Voltage 160-260 Volts Ac, 50 Hz Ac Supply Power Factor ≫0.95, Luminious Efficacy ≫100 Lumens/Watt, Cct 5700&Deg;K &Plusmn;300&Deg;K, Surge Protection Not Less Than 10Kv Complete Etc As Requred. , Fabrication, Supplying And Fixing Class B Galvanised Single Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipe With Tightening Bolts Complete As Required , Supply Of 14/15 Watt Led Retrofit Lamp Suitable For B22 Holder , Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
19.
Public Administrative Department #11181009 Price Bid
Tender for Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:3:6 (1 Cement : 3Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection,Emiemc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).45 Watt , Supply And Fixing Of 32Mm Dia X 1 Meter Long G.I. Pipe (Medium Class) Bracket For Mounting Of Fluorescent/Hpmv/Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos 25Mm X 6Mm Flat Iron Clamps With Nuts, Bolts And Washer , Painting The Flat Iron With Primer And Finish Paint Etc. As Reqd. , Fabrication, Supplying And Fixing Class B Galvanised Double Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipe With Tightening Bolts Complete As Required
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
20.
Public Administrative Department #11181008 Price Bid
Tender for Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:3:6 (1 Cement : 3Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Supply And Fixing Of 32Mm Dia X 1 Meter Long G.I. Pipe (Medium Class) Bracket For Mounting Of Fluorescent/Hpmv/Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos 25Mm X 6Mm Flat Iron Clamps With Nuts, Bolts And Washer , Painting The Flat Iron With Primer And Finish Paint Etc. As Reqd. , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -15 Deg To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri 80 , Under Voltage And Over Voltage Protection,Emiemc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).45 Watt
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
21.
Power #11168099 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , St Pole 13 M- Is 410 Sp- 72 , Stay Set 16X1800 , Acsr Dog Conductor , Acsr Weasel Conductor , A.B.Cab. L.T. (3X95)+ (1X70)+ (1X16)Sq.Mm , A.B.Cab. L.T. (3X120) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Earth Rod 2540X20 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Composite Polymer Pin Insulator , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Composite Polymer Pin Insulator , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Ms Channel 100X50 Mm , 33 Kv Cross-Arm 100X50 Mm V-Type , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Gi Wire 5 Mm/6 Swg , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Xlpe Cable Box 3X300 , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , 11 Kv Cable Box O/D 3X185sq.Mm , M.S. Angle 75X75x6 Mm , M.S. Angle 65X65x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , Stay Set 16X1800 , Stay Set Gi 20X1800 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , Ms Channel 100X50 Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Cross-Arm 100X50 Mm V-Type , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Disc Fitting 45 Kn (T&C) , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Composite Polymer Pin Insulator , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , Ms Angle 75X75x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection & Fixing Of Single Pole Structure Of Following Pole Of 11 Kv Line Along With X-Arm And Pin Insulator After Digging Of Suitable Pits Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , St Pole 13 Mtrs , Erection Of 11Kv Double-Pole Structure After Digging Of Suitable Pits On Following Pole With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , Erection Of 33Kv Double-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Tri-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Four-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection & Fixing Of 33Kv St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Grouting Of Following St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Plain Cement Concrete Pole 8.5 , Plain Cement Concrete Pole 11 Mtr. Long , Stp 13 Mtrs Long , Construction Of T/F Plinth Suitable For 160/250/400 Kva T/F (Size 2X2x1.5 Mtr) After Digging Of Earth And Construction With 14 Bag Cement, Fine Sand, Coarse.Sand, Brick Ballast, 1St Class Bricks 6000, Stone Ballast (40Mm), Ms Channel 125X65mm (54 Kg), Ms Twisted Bar 20 Mm (50 Kg) & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100/250 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , 250 Kva Transformer On Plinth , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Providing And Installation Of Maintenance-Free Chemical Earthing System For 250 Kva Distribution Transformer, Comprising Of Supply And Erection Of Approved Make Chemical Earth Electrode (Gi/Copper Bonded, Of Standard Length And Diameter) Installed In Drilled/Bored Hole Of Required Depth In All Types Of Soil, Including Backfilling With Highly Conductive Earthing Compound (Bfc/Graphite Based) To Achieve Low And Stable Earth Resistance; Providing Separate And Distinct Earthing For Transformer Body, Neutral And Lightning Arrester (If Applicable) Using Required Number Of Chemical Electrodes Interconnected Where Necessary; Construction Of Earth Pit Chamber With Brick Masonry, Plastering And Heavy Duty Ci/Rcc Cover With Provision For Watering/Inspection; Providing And Laying Of Gi Strip (E.G., 50×6 Mm) Or Suitable Copper Strip From Transformer Body, Neutral Point And La To Respective Earth Electrodes, Including All Connections With Nuts, Bolts, Washers, Lugs, Clamps And Anti-Corrosive Treatment; Testing Of Earth Resistance To Ensure Values Within Permissible Limits As Per Is/Respo Standards And Ensuring Long-Term Stability Without Frequent Maintenance; The Scope Includes Cost Of All Materials Such As Chemical Electrodes, Backfill Compound, Gi/Copper Strips, Bricks, Cement, Sand, Covers, Water, Etc., And All Labour, Drilling, Installation, Refilling, Carriage, Loading/Unloading, Handling, Testing, Commissioning And All Tools & Plants (T&P) Required For Complete And Satisfactory Execution Of Work As Per Standard Specifications And Direction Of Engineer-In-Charge. , Construction Of Safety Fencing (Ms) Size 3X3x2 Mtr. For Dist. Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle/T-Iron To Be Fitted On Vertical Posts. Pickets (If Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 65X65x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Providing, Installing, Testing And Commissioning Of Tailless Unit Suitable For 250 Kva Distribution Transformer, Including Dismantling Of Existing Tail Connections (If Any), Supply And Fixing Of Required Lt/Ht Connectors, Busbar Arrangements, Insulated Sleeves, And Necessary Termination Accessories; Complete Modification Of Transformer Lt Side To Tailless Configuration Ensuring Proper Phase Segregation, Insulation And Mechanical Strength; Including Providing And Fixing Of Suitable Size Aluminium/Copper Lugs, Glands, Ferrules, Heat Shrink Sleeves, Pvc Insulation Tape, Nut-Bolts, Washers And All Jointing Materials As Required; Making Proper Cable Terminations, Dressing And Clamping Of Cables With Gi Clamps; Providing And Ensuring Effective Earthing Of The Tailless Unit With Gi Strip/Wire And Connecting To Existing Earthing System; Including Painting Of Modified Portion With Suitable Anti-Corrosive Paint; Complete Testing For Continuity, Insulation Resistance And Proper Load Transfer; The Work Shall Be Carried Out As Per Relevant Is Standards, Respo/Departmental Specifications And As Directed By Engineer-In-Charge; The Rate Shall Include Cost Of All Materials, Labour, Tools & Plants (T&P), Handling, Loading/Unloading, Transportation, And All Incidental Works Required To Complete The Job In All Respects. , Providing, Laying, Jointing And Commissioning Of 140/200 Mm Dia (Od) Pn-4, Pe-80 Grade Uv Stabilized Hdpe Pipe In 6.0 Mtr Standard Length By Trenchless (Hdd/Drilling) Method For Underground Cable Protection, Including Excavation Of Suitable Size Launching And Receiving Pits, Alignment And Preparation Of Bore Path, Drilling, Reaming And Insertion/Pulling Of Hdpe Pipe, Jointing By Butt Fusion/Electrofusion With All Necessary Fittings Such As Couplers, Bends And End Caps, Ensuring Proper Alignment And Leak-Proof Joints; Including Providing And Laying Of Warning Tape, Route Markers And Identification System; Complete With All Required Tools & Plants (T&P) Such As Hdd Machine, Drilling Machine, Compressor, Generator, Welding Machine, Including All Consumables, Loading/Unloading, Handling And Safe Stacking At Site; Including Dewatering (If Required), Traffic Control, Barricading And Safety Measures; Also Including Restoration Of Road, Footpath, Drain Or Any Other Surface Under Row (Right Of Way) Conditions To Original Condition And Disposal Of Surplus Earth/Muck; Complete In All Respects As Per Relevant Is Standards, Respo/Departmental Norms And Direction Of Engineer-In-Charge, With All Material, Labour, T&P, Transportation And Incidental Charges Included In The Rate. (Rate Will Be Charge As Per Actual Length Of Work) , 200 Mm Dia For 33 Kv Line , 140 Mm Dia For 11 Kv Line , Laying Of Following Cable Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge.(Rate Will Be Charge As Per Actual Length Of Work) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Manually Digging Excavation Of Trench Of Size 0.50 M Width × 1.00 M Depth In All Types Of Soil Including Dressing, Levelling And Disposal Of Surplus Excavated Earth Within Specified Lead As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Supplying And Laying Of Brick Masonry (Class Designated) In Cement Mortar For Side Protection, Providing And Filling Of Sand Cushioning At Bottom And Around The Laid Cable, Followed By Laying Of Plain Cement Concrete (Plain Cement Concrete) Of Required Grade For Base And Protective Covering Over Trench; Thereafter, Placing And Proper Alignment Of Xlpe Cable Within The Complete Trench, And Covering The Trench With Brick/Cc Slab Protection Including Backfilling With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; The Scope Of Work Includes Cost Of All Labour, Materials (Bricks, Sand, Cement, Aggregates, Water Etc.), Handling, Loading/Unloading, Carriage, And All Tools & Plants (T&P) Required For Excavation, Laying And Finishing Works, With All Safety Precautions, As Per Standard Specifications And Directions Of Site In-Charge. (The Firm Will Be Fully Responsible For This Work And Taking Necessary Permission), As Per Direction Of Site Incharge (Rate Will Be Charge As Per Actual Length Of Work). , Laying And Installation Of 11 Kv Grade, 3 Core × 185 Sq.Mm Xlpe Insulated, Armoured Aluminium Conductor Cable In Underground Trench In Double Circuit Formation, Including Careful Handling, Dressing And Alignment Of Cable Along The Route As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Laying Of Cable Over Prepared Sand Bed, Maintaining Proper Spacing Between Circuits, And Ensuring Identification And Phase Marking; Providing Extra Length Of Cable At Both Ends In Loop Formation For Future Jointing/Termination (Spare Cable To Be Left In Loop Shape At Each End) As Specified; Covering Of Cable With Sand Cushioning, Protective Bricks/Tiles/Cc Slabs And Backfilling Of Trench With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; Including Supply Of All Consumables Such As Sand, Bricks, Cable Markers, Route Indicators, Etc., And All Labour, Loading/Unloading, Carriage, Handling Charges, Testing Prior To Commissioning, And All Tools & Plants (T&P) Required For Safe And Proper Execution Of Work As Per Standard Specifications And Site Instructions. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Dog Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying And Stringing Of Following Lt Aerial Bunched Cable (Abc) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Lt Aerial Bunched Cable (Abc) (3×95 + 1×70 + 1×16 Sq.Mm) , Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 4Mm/ 8 Swg , G.I. Wire 5Mm/ 6 Swg , Grouting & Fixing Of Stay Set (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Stay Set (16X1800) , Stay Set Gi (20X1800) , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Dead & Clamp , Suspension Clamp , F-Bracket With Clamp , Cross Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Fuse Set Complete On 25/63/100 Kva Transformer In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad 300X300x75 Of Approved Quality And Specified Size At Pole/Support Locations, Including Excavation Of Suitable Size Pit, Preparation Of Base, Dressing, Leveling, And Proper Placement In Line And Level As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge, Including Refilling, Ramming And Consolidation To Ensure Stability; The Scope Of Work Includes Cost Of All Labour, Loading/Unloading, Carriage, Alignment And All Incidental Works Required For Complete Execution, And All Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable M.S. Clamp, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site, And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Barbed Wire Of Approved Quality And Specification In Position, Stretched And Secured On Poles/Structures With Suitable Binding Wire, Staples, Clamps Or Other Approved Means, Maintaining Proper Tension, Alignment And Height As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing, Tightening And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Stay Insulator Of Approved Make, Type And Rating In Stay Set Assembly, Including Proper Placement Between Stay Wire Lengths, Making Necessary Connections, Tightening And Ensuring Correct Alignment And Insulation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of I-Bolt Of Approved Size And Quality For Guarding Angle, Complete With Nuts, Bolts, Washers And Necessary Accessories, Including Drilling Of Holes In Angle/Pole As Required, Proper Insertion, Fitting, Tightening And Ensuring Correct Alignment And Rigidity As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Number Plate Of Approved Size, Design And Material With Proper Painting/Printing Of Identification Number And Lettering, To Be Securely Mounted On Pole/Structure At Suitable Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fixing With Suitable Clamps, Nuts, Bolts Or Binding Wire As Required, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Necessary For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Draw Out Fuse Set Of Approved Make And Rating, Complete With All Standard Accessories, Mounted On Pole/Structure With Suitable Clamps, Nuts, Bolts And Connectors, Including Proper Alignment, Tightening And Making Necessary Electrical Connections For Safe And Reliable Operation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Erection, Testing And Commissioning And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment, Tackles And Testing Instruments Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Smc Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable Clamps, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Paint And Carrying Out Painting Of Pole With Approved Quality Paint System, Including Thorough Surface Preparation By Cleaning, Scraping, Wire Brushing And Removal Of Rust, Dirt And Loose Materials, Applying Primer Coat Where Required And Finishing With Two Or More Coats Of Approved Paint Of Specified Shade, Including Marking/Numbering If Directed, Complete In All Respects As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage Of Materials To Site And All Incidental Works Necessary For Satisfactory Completion, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Construction Of Meter Room Of Internal Size 8× 8× 10 Height, Including Setting Out, Excavation Of Foundation In All Types Of Soil, Dressing And Disposal Of Surplus Earth Within Specified Lead; Providing And Laying Plain Cement Concrete Of Required Grade For Foundation Base, Followed By Construction Of Brick Masonry In Cement Mortar Of Approved Class For Foundation And Superstructure Walls Of Required Thickness, Including All Leads And Lifts; Providing Reinforced Cement Concrete Lintel And Roof Slab (Solid Slab) Of Required Thickness Using M-20 Grade Concrete With Centering, Shuttering, Vibration And Curing Complete, Including Reinforcement Steel As Per Design; Providing Internal And External Plastering In Cement Mortar Of Required Thickness, Smooth Finishing, And Curing; Providing Flooring With Cement Concrete Or Ips Finish, Including Base Preparation And Finishing; Supplying And Fixing Of Ms/Steel Door With Frame, Including Holdfasts, Hinges, Locking Arrangement And Painting; Providing Ventilators With Ms Grill, Including Fixing; Complete Internal And External Painting/Whitewashing With Approved Quality Paint; Providing Necessary Provisions For Meter Installation Such As Cable Entry Points, Sleeves, Earthing Arrangement, Foundation Bolts And Fixtures; The Scope Includes Cost Of All Materials Such As Bricks, Cement, Sand, Aggregates, Steel, Doors, Grills, Paint, Water, Etc., And All Labour, Tools & Plants (T&P), Scaffolding, Curing, Carriage, Loading/Unloading, Handling And All Incidental Works Required For Complete Construction As Per Standard Specifications And Direction Of Engineer-In-Charge. , Laying Of Power/Control Cable Of Specified Size In Trench/Duct/On Surface Along Approved Route, Including Excavation Of Trench, Sand Cushioning, Proper Dressing, Alignment, Clamping, Identification Tagging, Protective Covering With Bricks/Tiles (Where Required), Backfilling, Ramming, Leveling, And Disposal Of Surplus Earth; Including Handling, Shifting, Straightening, And Pulling Of Cable With Due Care To Avoid Damage And Maintain Required Bending Radius; Complete In All Respects As Per Standard Specifications And Direction Of Engineer-In-Charge, All Materials, Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
22.
Power #11144553 Technical Bid
Tender for Supply Of Electrical Spares And Minor Stores/Hardware Items From The Original Equipment Manufacturer, Their Authorized Dealer/Local Representative Or Local Ssi Units Registered Firms/Suppliers Already In The Trade For The Year 2026-27 , Hardware Fitings And Accessories,Clamps And Connectors For Acsr /Aaac Conductor , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Hardware Fitting For Aaac Panther Conductor 37/3.15Mm Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Hardware =7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Single Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Hardware = 9000Kg Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Suspension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Compression Type Repair Sleeve Suitable For Aaac Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Zebra/Moose Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , 4R Stock Bridge Type Vibration Damper Suitable For Aaac :Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Aaac Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , Mid Span Compression Joint For Acsr Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Zebra (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Moose (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Zebra To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Aaac Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Disc Insulator 70Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 70Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Without Anti Fog(Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Gi Nuts And Bolts Of Sorts (16Mmx35mm/ 40Mm/45Mm/50Mm & 65Mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx75mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx50mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (12Mmx50mm) Heavy Duty , Aluminium Cable Tray Of Size 400 Mm X3000 Mm , Aluminium Cable Tray Of Size 300 Mm X2500 Mm , M.S. Angle Iron Of Size (45X45x5)Mm , M.S. Angle Iron Of Size (50X50x5) Mm , Steel Tor Of Dia 8Mm , 10Mm, 12Mm For Cable Ducts , Spring Washers 16Mm Heavy Duty , G. I Wire Swg No. 8/ 4.06Mm Dia , Red Oxide Enamel Paint (Asian, Nerolac/ Berger) , Al. Paint (Asian, Nerolac/ Berger) , Smoke Grey Enamel Paint (Asian, Nerolac/ Berger) , Yellow/White Paint (Asian, Nerolac/ Berger) , Cement Permier (Asian, Nerolac/ Berger) , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T-Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975 Bimetallic Ct- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther With Clamp Sutitable For 132/33Kv CtS Of Ae Mumbai, Sct Gaziabad, Bhel Vidhyut Control Andhra, Mehru Bhiwadi/ Laxmi Engg Bhopal, Jyoti.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132/33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , P.I. Clamp For Acsr Zebra Conductor , P.I. Clamp For Acsr Panther Conductor , P.I. Clamp For Acsr Moose Conductor , P.I. Clamp For Acsr Moose Conductor , Twin Bushing Clamp Acsr Moose For 132/33Kv Transformer 1200Amp Without Poles , Twin Bushing Clamp Acsr Moose For 220/132Kv Transformer 1200Amp Without Poles , Isolator Jaw 1600Amp For 33Kv Isolator , Isolator Jaw 2500Amp For 33Kv Isolator , Isolator Jaw 1600Amp For 132Kv Isolator , Isolator Jaw 2500Amp For 132Kv Isolator , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , Jumpers Cone For Acsr Panther , Jumpers Cone For Acsr Zebra , Spacers For Acsr Zebra , Spacers For Acsr Moose , Spacers For Acsr Panther , Earth Wire Tension Clamp , Electrical Items And Spares , Shunt Capacitor Fuse 40A With Spring Complete Assembly , Silcagel Crystal Size 8- 8 Mesh , Silcagel Breather Box 10Kg , Aluminium Tape , Chemical Jelly , Grease , Distilled Water , Transformer Oil Sampling Bottle , Welding Electrodes Swg 8No As Per Is: 814 Of 2004 , Welding Electrodes Swg 10No As Per Is: 814 Of 2004 , Search Light With 300-500Mtr. Focus Make Flash, Equivalent Etc , Led Flood Light Complete 90/100Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 140/150Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 1900/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Street Light Fitting 190/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Lamp 9 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Led Lamp 15 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 18 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 45 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Lamp Holder Pendant/Angular (Anchor,Havells,L&T,Philips/Reputed Make) , Led Tube 4 Pin 18 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Mcb 5-10 annual periodical maintenance Two Pole (Havells, Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Two Pole (Havells,Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 32 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 63 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mccb 100 Amp, 4 Pole, Ics= 100% Icu (Havells, Standard, L&T) , Mccb 200/400/600Amp,4Pole,Ics=100% Icu(Havelles,Standard,L&T) , Main Iron Clad Switch Tpn 415V,400A , Rubber Mat 1Mtr X2mtr= 12Mm Thick , Cable Ferrules A To Z And 0 To 9 , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Copper Mesh (30Cmx5cm) , Copper Wire 8Swg , Copper Thimbles 8Mm , Copper Thimbles 10Mm , Alumunium Thimbles 2.5 / 6 Mm , Alumunium Thimbles 8 / 10 Mm , Fhelmet , Starter 36Watts , Tube Four Pin 36 Watts , Choke 36Watts , Rubberized Cork Sheet 6Mm , Rubberized Cork Sheet 10Mm , O-Rings For Bushings/Inspection Plates Of Transformer 5Mm-10Mm Diameter , Rubber Sealings For Marshalling Kiosks/Control & Relay Panels , Cooling Fans Of 3 Phase 50Mva , 33Kv Vaccum Interrupter Suitable For 33Kv Vcb Of Bhel,Abb,Gec Alstom,Seimens,Megawin, S&S Make , Thermal Overload Relay Seimens Make With Range 0.8-1.2 annual periodical maintenance , Thermal Overload Relay Seimens Make With Range 1.2A-2.5 annual periodical maintenance , Thermal Overload Relay Seimens Make Of 4A Max With Range 0.1-1Amp And 1.5A-1.2A , Mn2 Thermal Overload Relay With Start And Off/Reset Relay Of Range 0.9-1.5A L&T Make , Relay 500V,2A, Fuse 6Amp. Mn2 Make L&T , Relay 415V,3.2-5A,Class 10A Mn2 Makesiemens 3Ua50 00-1F , Relay 415V,Lth=10A,Le=4A Mn-A1 Make L&T , Dc Change Over Relay Dcco, Make Abbrxme-1-Rk221-052-Annrk711004 , Dc1 Supervision Make Abb Tsr-In352 , Anti Pumping Relay Make Schrack/Abb Or Equi , Auxillary Relay, Voltage Selection Relay 75A, Rxpsu14n-Imyn563646-Dau, Aux Voltage:110V Dc, Case Size:2S 12C, Contacts:13No+1Nc, Reset Type:Electrical, Flag:Yes, Make Abb , Auxillary Relay, Tc-1 Supervision Relay195, 7Pj1321-5Aa210aa0, Aux Voltage:24-23V Dc, Contacts:2C/O, Reset Type:Self Make Siemens , Numerical Relay, Dir. O/C & E/F Protection Relay67/67N 7Sj6611-5Eb90-1Fgo-Lor, Aux Supply:110/250V Dc, Case Size:1/3 19,16 Bi, 7 Bo,1 Life Contact,4*I, 4*U,Ct:1A, Vt:110V/220V,50Hz, Iec61850, 100 Mbit Ethernet, Electrical, Double, Rj45-Connector Make Siemens , Thermostat Make Apt/Veilco/Eq , Auxiliary Air Break Contactor Of Ac2/Ac3 Duty Cycle Number Of Poles 03, Voltage 415V, annual periodical maintenance 0-2 A, Contacts 2No+2Nc,Make Siemens , Magnetic Control Contactor Make Andrew Yule Power 44W Volt 110V Dc Ith 10A Is 13947 Iec 947 , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mnx12 Make L&T , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mna1 Make L&T , Contactor 415V, 20Amp 3Tf31 01-0A Make Siemens , Contactor 415V, 9Amp Lth 10Amp,Le 4Amp Mnx9 Make L&T , Auxillary Contactor 3Th3022-0B-F4, Aux Supply:110V Dc, Contacts:20O-2Nc 89Ax Make Siemens , Cooling Fans 3 Phase Motor,415V,560Watt,900Rpm,0.9Amp/1Amp(Size 600Mm) , Cooling Fans 3 Phase Motor,415V,700Watt,550Rpm,1.5Amp(Size 600Mm) , Digital Oti 90-250V Ac/Dc, Range 0-150Degree Make Precimeasure Control Banglore , Digital Wti Meter Make Precimeasure Control Banglore , Megawatt Meter , Digital Megawatt Meter, Bezel Size: 96*96Mm, 4-1/2 Digits, Aux Supply:110V Dc, Accuracy:0.5, Ctr:1200:800-400/1A Ptr:33Kv/110V Make Ae , Mvar Meter Digital Mvar Meter, Bezel Size:96*96Mm, 4-1/2 Digits, Aux Supply: 110V Dc, Accuracy:0.5, Ctr:1200-800-400/1A Ptr:33Kv/110V Make Ae , Ammeter Digital Ammeter, Bezel Size:96*96Mm, Aux Supply:110V Dc, Accuracy: 0.5, Range:1200-800-400/1A, Inbuilt Selector Switch Make Ae , Selector Control Switch Er Make 1224 Swiso , Digital Ac Ammeter,Makeae Digital 4, Range 0-600A, Ct Ratio 600/1A, Size 130X130 Mm. , Electronic Hooter, Aux. Supply 110V Dc, Freq. 48-63 Hz, O/P95-105 Db Size 96X96x82 Mm. , Lubricator Make Sae80w/90 Type Oil , Glass Sleeves , Crc Bottle , Teflon Tape , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Fan Contactor Seimens Ice 158.1 Auxiliary Contactor 2No+2Nc & 4No+ 4Nc , Seimens 3Ta6702 2 To 10A, Auxilairy Contactor 3No+2Nc,Cs3-P Iec947 En60947 V=6Kv Ac-1 690V-1A Ac-15 , Solder Flux , Single Core 300Sq Mm 33 Kv Voltage Grade,Al Conductor, Pvc Insulated, Sheathed, Armoured, Xlpe Cable Likely Make Havelles Etc , Pvc Unarmoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 4 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 6 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 8 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 10 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 12 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 16 Core , Pvc Copper Wire 1 Mmsq , Pvc Copper Wire 1.5 Sqmm , Pvc Copper Wire 2 Sqmm , Pvc Copper Wire 4 Sqmm , Pvc Copper Wire 6 Sqmm , Copper Glands 19/25/32Mm , Switch 5A , Switch 15A , Socket 5 Pin, 5A , Socket15 Pin, 5A , Fan Regulator 10A , Dp Switch 32A , Pvc Tape Roll , Indicating Pygmy Lamp 220V/110V Dc, Pin Type / Screw Type , Semaphore Indicator For Isolator S89a Ntc12, Aux Supply:110V Dc, With 3Kohm, 6W External Resistor Make Dav , Push-Button & Indicating Lamp For Ann. Accept 3Sb50 00-0Ab01+ 3Sb54 00-0A, Normal Actuator With Plastic Front Ring And Black Holder Contact (1N0+1Nc) , Auxillary Switch 8No+ 8Nc Make Shirka/Shubhada/Eq , Local Remote Switch Make Shirka/Switron/Kaycee , Rotary Switch, Local Remote Switch 8 Ways, Handle:Pistol Grip, Position:Local/Remote, Stay Put, (Local-4Ways, Remote-4 Ways), 25A; Lockable Type, Bezel Size:75 Sq.Mm , Limit Switch 3Se3 023-0A, Contacts:1No+2Nc Make Siemens , Control Switch Bcs 3 Position ,Pistol Grip 16 Ways Make Switron , Control Switch Bcs 3 Position ,Pistol Grip 20 Ways Make Switron , 3 Core 95 Sq Mm 11Kv Xlpe Cable , Sf-6 Gas Cylinder Of 9Kg , Sf-6 Gas Cylinder Of 11Kg , Nitrogen Cylinder Of 16Kg Containing 9Kg Gas , O2 Cylinder Refilling , Anti Rodent Device , Control Switch For Panels Reputed Make , Hrc Fuse 2Amps , Hrc Fuse 4Amps , Hrc Fuse 6Amps , Hrc Fuse 10Amps , Hrc Fuse 10Amps , Hrc Fuse 32Amps , Hrc Fuse 32Amps , Hrc Fuse 100Amps , Fuse 3Nw20nnsf+3Nwns10, Aux Voltage:110V Dc, Rating:10A Make Siemens , Fuse 3Nw20nnsf+3Nwns4, Aux Voltage:110V Dc, Rating:10A Make Siemens , 33Kv Phase Limb Of 33Kv Circuit Breaker (Abb Make) , Breather Box For 133.33 Mva/160 Mva/150Mva, 220/132 Kv Transformer (Bhel/Abb Make) , Breather Box For 50 Mva,132/33 Kv Power Transformer (Bhel/Cgl/Ece/Emco Make) , Numerical O/C And E/F Relay Make:Easun Reyrolle , Model: Mit 114,Poles:4No,Volt: 43-280V Dc,Amp:1A , Numerical Differential Relay For Power Transformer Protection Make Ashida,Er/Reputed Make , Master Trip Relay B24,110/125 V Dc Make Er/Reputed , Master Trip Relay B24,220 V Dc Make Er/Reputed , Master Trip Relay 86, Rxmvb2-1Myn563035-Ad Make Abb , Trip Relay Supervision Relay 95 Tsr-1N352-001-As, Make Abb , 33Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt :33Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 66Kv Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 66Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A , 132 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 132Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 220 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt : 220Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 2 Pole Heavy Duty Rotary Switch With Off 5Amp Make Key Cee Equivalent Etc For C&R Panel , Shunt Tripping/Closing Coil 110V/220V Dc, Suitable For 33Kv Vcb Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make Etc , Shunt Tripping/Closing Coil 110V/220V Dc,Suitable For 66Kv Sf6 Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make , Spring/Charging/Closing Coil 220V/110V Dc, Suitable For 33Kv Vcb Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 33 Vcb Of Abb Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 132 Sf6 Of Abb Make , Tnc Switch 110/220V Dc 4Ways , Tnc Switch 110/220V Dc 8Ways , Tnc Switch 110/220V Dc 12Ways , Vrla Battery 12V,80/160Ah Along With Charger , Space Heater Sh100w240, Rating:100W 240V Ac Make Apt Control , Resistor Unit For Master Trip Relay 86 Rxtma-1Nrk711004-Aa Make Abb , Geared Motor For 100-130V Dc/Ac 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Ac For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Spring Charge Motor 230V Ac/Dc , 1.8A, Type Sg105, Insulation Class B, Rpm 60 For 36Kv Vcb Make Agni/Shreem/Reputed Make , Spring Charge Motor 230V Ac/Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Spring Charge Motor 230V Ac/Dc 2.5A For 132 Kv Sf6 Circuit Breaker (Siemens Make) , Auxilliary Contactor 110V Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Operating Coil 24V Dc maintenance of For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 maintenance of Opening Coil 48V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(110V-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(220-250V Dc/220V-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shunt Closing Release-Mc 24V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mc Closing Coil(48V Ac-Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(110-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 24V Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 48V Ac- Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly(110-132V Dc/110-127V Ac) Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mu Coil Assembly(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 24Vcc Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(48Vca-Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(110-127Vca/110-132Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 220-250Vca/220-250Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shock Absorber Assembly For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Acsr Zebra Conductor , Acsr Panther Conductor , Acsr Moose Conductor , El3 Drive Complete(Operating Mechanism) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Transformer Oil , Motor Operated Change Over Ac240v/Dc220v 100 annual periodical maintenance (Breaker Type) , Singhle Phase 50 C/S, Outdoor Metal Oxide Gapless Type ,30Kv(Rms) Surge Arrester Including Surge Counter/Monitor,Insulating Base Plate And All Associated Assessories Auxilliares , 33Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95Kvp Dry Lightning Impulse Withstand Voltage ± 170 (Kvp) , 132Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 275Kvp Dry Lightning Impulse Withstand Voltage ± 650 (Kvp) , Single Phase 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries. , Single Phase, 50 C/S 145Kv Current Transformers (900-600-300/1-1-1-1-1 A Or As Per Site Specifications), 31.5Ka For One Second, Rated Dynamic Current 100Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S 132Kv Capacitor Voltage Transformers (132/√3) Kv/ (110/√3)V, One Min Power Freq Withstand 275Kvrms , Single Phase, 50 C/S 36Kv Current Transformers (1200-600-300 /1-1-1 A Or As Per Site Specifications) , 25Ka For One Second, Rated Dynamic Current 25Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S Outdoor 33Kv Pt (33/√3) Kv/ (110/√3)V With Highest System Voltage36kv, One Min Power Freq Withstand 70Kvrms , Marshalling Kiosk With Kiosk Frames Mild Steel Structural Sections For Pressed And Shaped Cold-Rolled Sheet Steel, Thickness Not Less Than 2.0 Mm. Frames Shall Be Enclosed In Cold-Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Doors And Covers Shall Also Be Cold Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Complete Structures Shall Be Rigid, Self Supporting, Free From Flows, Twists And Bends. Dust And Vermin Proof Construction And Shall Be Provided With A Degree Of Protection Of Ip: 55, With Copper Bar Earthing. Finishing Paint On Panels Shall Be Of Shade 692 (Smoke Grey) Of Is: 5. The Inside Shall Be Properly Stoved. The Paint Thickness Shall Be At Least 50 Microns , Single Phase 36Kv 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries , T&P Items And Safety Equipments , Turn Table For Acsr Panther/Zebra Conductor With Capacity Of 3Mt Made Of Mild Steel With Double Ball Bearing Likely Makes Pee, Zi, Honeywell, Burma Etc , Four Sheeve Pulley Steel Frame Forged Swivel Hookwith Capacity Of 5Mt As Per Is 8610 Pulley Material And Ball Bearing Of Gun Metal Bush With Open Type Pulley Isi Mark Suitable For 12Mm Steel Rope , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/3.15Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/2.88 Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Zebra Conductor 54/7/3.18Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp For Earth Wire Size 7/3.66Mm Groove According To Size Of Earth Wire Bolts Of High Tensile Steel Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Galvanized Pulley Size 6 Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing. , Al Alloy Snatch Roller Pulley Size 8Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Roller Pulley Size 6Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Earthwire Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Tool Kit , D-Shackle Heavy Duty , Chain Block Pulley Heavy Duty 5 Ton , Avo Meter Likely Make Motwani, Waco, Riken Etc , Hook On Meter Likely Make Motwani, Waco, Riken Etc , Insulating Hand Gloves Make Crystal Etc Tested For 220 Kv, 132 Kv , 33Kv Level , Safety Helmet Isi Marked , Safety Belt Isi Marked , Safety Vest Isi Marked , Rain Coat Of Duck Back Make Etc , Safety Shoes Of Reputed Make Etc , Fixed Piller Drill Machine 40Mm , Polypropylene Rope ½, ¾& 1 / Garware Make , Manila Rope ¾ & 1 Dia , Steel Wire Rope Sling 16Mm Dia Isi Make 2 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 5 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 10 Mtr. Long Heavy Duty , Steel Wire Rope Of Dia 16 Mm , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 220Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 132Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 33Kv Voltage Level , Hydraulic Conductor Cutter , Hydraulic Compressor Manually Operated For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Hydraulic Compressor Motorised For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Compressor Die Sets Suitable For Above Hydraulic Compressors , Drum Lifting Jack Mechanical 3 Ton Capacity , Single Sheeve Pulley Both Open And Close 5 Ton Capacity , Double Sheeve Pulley 5 Ton Capacity , Three Sheeve Pulley , Petrol Chain Saw Cutter , Earthing Roller , Equilizer Pulleys 10 Ton , Earth Wire Pulley , Single Sheeve Roller Aluminium, Rubberized Dia 300/400 Mm , Single Sheeve Roller Aluminium, Dia 450/600 Mm , Twin Aerial Roller, 150Mm (Rubberized) Aluminium , Twin Aerial Roller, 150Mm (Rubberized) Nylon (P.P) , Patta Clamp , Kitto Clamp , Turn Buckle Capacity 5 Ton , Joint Proctector For Various Conductors , Sagging Winch Machine 10 Ton , Single End Socks , Double End Socks , Earth Wire Socks , Power Winch Machine 5 Mt , Sag Plate , Single Pulley 150Mm Dia (Aluminiun/ P.P) , Automatic Clamp For Conductor/ Opgw , Crow Bar, 30Mm To 32 Mm , Derrick Pole, S-Type Roller , Air Compressor With Ac Single Phase Air Cooled 12 Cfm Compressor And Tank Pressure 100 Psi Make Maxair/Reputed Make , Paint Spray Gun 45Psi , Old Cotton Saree , Digital Mutltimeter (Mutli Functional Meter) , Military Grade Binocular (Reputed Make) Magnification Between 7X To 12 X And Objective Lense Diameter , Axe/Sickle , Professional Chain Saw 58Cc, 20 Inches, 3.75 Hp , Bush Cutting Machine Heavy Duty (Reputed Make) , Meggar , Earth Tester , Digital Insualtion Tester , Earth Test Field Kit , Oil Bdv Kit , Thermovision Camera Having Resolution 640*480, Wavelength 8-14Um, Thermal Sensitivity =0.05°C , Automatic Identification Lens With Manual/Electric/Automatic Focusing, Fov- 25°X19°; High Brightness Sunlight Screen, With 4X Digital Zoom, Hdmi Output, 500Million Pixels, Laser Positioning Points Displayed On The Image,With 32Gb Memory Space, Video Recording, Temp Range: -2O Degree To 650 Degree Centigrade, Having Rechargaeble Liyhium Ion Battery , Primary Injection Kit With 1000 Amperes Rating Accuracy ±0.5% Power Supply(Ac) 220V±10%·25A, 50Hz/60Hz Or 110V±10%·50A, 50Hz/60Hz Current Output (Ac) 1000A·5V Or 500A·10V Capacity 5Kva The Current Output Waveform Distortion ≤5% Dual Protection Overload Electronic Protection And Software Protection Range 0-1100A Resolution 0.1A, Accuracy 0.5%, Secondary Measurement Range 0-6A Resolution 0.001A, Accuracy 0.5%, Current Duration 1000A Range 1000A 2-3Minutes 500A 3-6Minutes 500A Range 500A 2-3Minutes Continuous Output 0-400A With Timer Range 0.0001~999.99S Resolution 0.001S Accuracy 0.2% ±2 Words Standard Standard Iec61010-1;Iec 61326-1 Communication Port Rs232 Cable Length 2X6m, 70Mm² , Cgi Sheet , Spanner Set , Fire Fighting Equipments , Refilling Of Dry Powder 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 15Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 25Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 50Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 2Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 5Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Mechanical Foam Type 50 Ltrs (Make Freeze Fire/Reputed Make) , Refilling Of Co2 Type 4.5 Kg , Refilling Of Co2 Type 10 Kg , Refilling Of Co2 Type 12.2 Kg , Refilling Of Co2 Type 22.5 Kg , Hose Pipe For Dcp 10 Kg , Hose Pipe For Dcp 25 Kg , Hose Pipe For Dcp 50 Kg , Hose Pipe For Abc 2 Kg , Hose Pipe For Abc 5 Kg , Hose Pipe For Abc 10 Kg , Hose Pipe For Mechanical Foam Type 50 Ltrs. , Hose Pipe For Co2 4.5 Kg , Hose Pipe For Co2 22.5 Kg , Wheel Set For Dcp 25 Kg , Wheel Set For Dcp Co2 22.5 Kg , Wheel Set For Dcp/Mechanical Foam 50 Kg , Union Cap For Dcp 10Kg , Union Cap For Dcp 25Kg , Union Cap For Dcp 50Kg , Dry Powder Fire Extinguisher 25 Kg Trolly Mounted Filled With Bc Dry Powder Fitted With Hose Pipe/ Nozzle Is No: 10658 Used On B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Type Fire Extinguisher 6Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Typefire Extinguisher 9Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Carbon Dioxidetype Fire Extinguishers Seamless 4.5 Capacity Wheel Type Fitted With Isi Marked Value, Hose/Horn Filled With Co2 Gas Applicable On Class B,C Fires Is 15683 Make Cease Fire,Savemax,Reputed Make , Mechanical Foam 50 Ltrs. Fire Extinguishertrolly Mounted Filled With Afff Concentrate Fitted With Hose Pipe/ Nozzle Is No: 13386 Used On A & B Class Of Fire Make Cease Fire,Savemax,Reputed Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
23.
Defence #11132896 AOC
Tender for Supply Installation Testing And Commissioning Of Three Phase Isolation Transformer , 3-Phase, 50 Hz, Indoor Type Copper Wound Oil-Cooled , Class Of Insulation- A , Metallic Body Powder-Coated , Designed For Input Voltage: 415 V ±5% , Output Voltage: 415 V ±5% With Ratio Of 1 : 1 ,Vector Group: Dyn11 (Delta-Star) , Efficiency: 95% , Separate Neutral Bushing Brought Out For Earthing Neutral-To-Earth Potential: 1 V, Accessories / Fittings Digital Temperature Meter , Lifting Hooks (1 Set), Earthing Terminals (2 Nos) Optional Protection , Overload / Short-Circuit Protection , With First Fill Of Transformer Oil Of Requisite Di Electric Strength Up To Level Of Capacity 100 Kva Complete All As Specified And Directed . , , Supply Installation Testing And Commissioning Of Voltage Stabilizer For Automatic Operation, Three Phase Naturally Oil Cooled Indoor Type & Designed For Input Variation Between 340 V To 460 V With Output Voltage Stabilized At 415 With Accuracy ± 1% And Speed Of Correction 50 Volts Per Second And Of Capacity 100 Kva Complete All As Specified And Directed. Make: Volina / Ite Gurgaon/ Brentfort/ Indian Transformer Limited/ Vintek/ Jaybee/ Aplab/ Savio. , Supply, Lay, & Testing Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armored, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Following Size: - 70 Sq Mm 3½ Core Complete All As Specified And Directed , Excavation In Trenches, Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth For Foundations Etc, Or For Shafts, Wells, Cesspits, Man Holes, Pier Holes Etc Not Exc 10 Sq M On Plan And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. , Returning, Filling In Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding 25 Cm In Soft / Loose Soil Complete All As Specified And Directed. , Removing Excavated Materials (Soil) Not Exceeding 50 M And Depositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Specified And Directed. , Material And Labour For Sand Cushioning For Cable Protection Using Clean Dry Sand Complete All As Specified And Directed. , Supply & Laying Well Burnt Brick , Locally Available Best Quality (Sub Class B Bricks ) Laid In Trenches Perpendicular To Ug Cable Protection Complete All As Specified And Directed , Supply Laying & Fixing Gi Pipe Light 80Mm Dia , Isi Marked ,Of Required Length For Protection Of Cables In Wall/Pole/Under Road Complete Including Necessary Ms Clamps , Nuts , Bolts & Washers Etc Complete All As Specified And Directed. , M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode Of Size 600 X 600 X 6 Mm Thick Buried Directly In Ground To A Depth Not Less Than 2.25 Mtr Below The Normal Ground Level With Top Edge Of Earth Plate Not Less Than 1.50 Mtr Below The Normal Ground Level And Connected To Gi Strips 32 X 6 Mm By Means Of Nut, Bolt & Washer And Protected By 40Mm Dia Gi Pipe Light Grade And Watering Pipe Of 20Mm Dia Gi Pipes Light Grade And Connected To Earth Test Point Including Necessary Excavation, Earth Work, Plain Cement Concrete Chamber (1:3:6) Type C-1 And 40 Mm Thick Reinforced Cement Concrete Pit Cover In Reinforced Cement Concrete (1:2:4) Type B-1 Using 6 Mm Dia Ms Round Bars @ 150 Mm C/C Both Ways All As Shown In Electrical Plate No. 5 Of Ssr Part-I All As Specified And Directed. Notes : The Unit Rate Includes For Protection Pipe And Gi Strip From Top Of Earth Plate Up To 7.00 Meter Above Ground Level Complete All As Specified And Directed. , M&L In Replacement For Earthing Complete With Copper Earth Plate Electrode Of Size 600 X 600 X 3.15 Mm Thick Buried Directly In Ground To A Depth Not Less Than 2.25 Mtr Below The Normal Ground Level With Top Edge Of Earth Plate Not Less Than 1.50 Mtr Below The Normal Ground Level And Connected To Copper Strips 20X3 Mm By Means Of Copper Nut, Bolt & Washer And Protected By 40Mm Dia Gi Pipe Light Grade And Watering Pipe Of 20Mm Dia Gi Pipes Light Grade And Connected To Earth Test Point Including Necessary Excavation, Earth Work, Plain Cement Concrete Chamber (1:3:6) Type C-1 And 40 Mm Thick Reinforced Cement Concrete Pit Cover In Reinforced Cement Concrete (1:2:4) Type B-1 Using 6 Mm Dia Ms Round Bars @ 150 Mm C/C Both Ways All As Shown In Electrical Plate No. 5 Of Ssr Part-I Complete All As Specified And Directed Notes : The Unit Rate Includes For Protection Pipe And Copper Strip From Top Of Earth Plate Up To 7.00 Meter Above Ground Level. , Supply And Fixing Of Gi Strip 32 X 6 Mm Fixed In Ducts / On Wall / In Trenches / Floors Etc For Earthing Complete Fixed To Equipment / Test Point / Earth Electrode Duly Brazed Complete All As Specified And Directed , S& F Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit /Pipe Or Fixed To Poles Duly Fixed Over Insulators Or Any Other Indicated Situation For Loop Earthing Etc As Required With 32 X 6Mm Copper Strip Duly Brazed Complete All As Specified And Directed. , M&L Heat Shrinkable End Jointing Kit (Outdoor Type) Suitable For 1100 Volts Grade Lt Under Ground Cable Of Sizes From 70 To 150 Sqmm 3.5 Core As Per Requirement At Site Complete All As Specified And Directed . , Design Fabricate, Supply, Install Testing And Commissioning Of Lt Feeder Pillar Box, Cpri Approved Outdoor Type Fabricated With 3.15 Mm Thick Crca Sheet Steel Front And Rear Openable Double Door Vertical Type Installed Over Properly Supported Legs Not Less Than 450Mm Above Ground Level Suitability Grouted To Plain Cement Concrete With Copper Bus Bar 200 Amps Including Following Accessories : - (A) Mccb 160A Four Pole - 01 Nos (Incomer) (B) Digital Voltmeter 0-500 V With Selector Switch-1 Set (C) Digital Ammeter 0-30 annual periodical maintenance With 3 Nos Cts & Selector Switch - 02 Set (D) Phase Indicator Lamps (Ryb) - 01Set , Surface Dressing In Soft Loose Soil N Exc 15 Cm Deep And Getting Out Complete All As Specified And Directed. , Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum,In Soft/Loose Soil And Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, Complete All As Specified And Directed. , M&L Cement Concrete With Plain Cement Concrete Type C2 (1:3:6) Using 40Mm Graded Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And Directed. , M&L For Brick Work With Burnt Old Size Bricks Built In Cement Mortar 1:6 Straight Or Curved On Plan Exceeding 6Mtr Mean Radius Complete All As Specified And Directed. , M&L For Broken Stone Or Boulders Of Hardcore Of Gauge N Exc 63 Mm Deposited, Spread And Levelled In Layers N Exc 15 Cm Thick Watered And Rammed To A True Surface Complete All As Specified And Directed. , M&L For 100Mm Thick Plain Cement Concrete Type B2 (1:2:4) Using (40Mm Gradded Aggregate) As In Hardstanding/ Sub Base Complete All As Specified And Directed. , M&L Rendering 15Mm Thick On Other Than Fair Faces Of Brick Or Concrete Surfaces In Cement Mortar (1:6) Finished Even And Smooth Complete All As Specified And Directed. , S&F Pre Painted Galvatume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall Fixed With Self Tapping Screws Complete All As Specified And Directed.Make: Dura Roof /Jsw / Dyna Roof/ Jindal , S&F Pre Painted Galvatume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall Fixed With Self Tapping Screws Complete All As Specified And Directed. Make: Dura Roof /Jsw / Dyna Roof/ Jindal , S&F Steel Work In Tubular Trusses Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161 1979 Grade St.-240 Conforming To Fe-410-W Gde E-250 Quality -A Complete All As Specified And Directed. , M&L Painting Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer To New Steel Surfaces Of Any Description, Not Otherwise Described, Over 10Cm Width Or Girth Complete All As Specified And Directed.
Contract Date: May 30, 2026 Contract Value : 88.16 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
24.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
25.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
26.
Tourism #11085444 Technical Bid
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer. , Supplying And Filling Moorum In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry In Cement Mortar 1:3 (1Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg /Cm2. B. Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs, Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of Sail, Tata, Vizag Made Only (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. Minimum Grade Of Steel - Fe 500 , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4B Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint.In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Providing & Fixing In Position Galvalume/Zincalume Flashings, Cappings, Ridges, Gutters Upto 600Mm/610Mm Girth And Min 3.00M In Length (Cold Rolled Steel 550 Mpa Yeild Stress Astm A 446 Grade E) With Hot-Dip Metallic Coating Of Aluminium-Zinc Alloy(Az 150 Galvalume) (150 Gms/Sqm Total Of Both Sides With Al-Zn Composition= 55% & 43.5% Resp. & 1.5% Si Conforming To Astm 792/ As 1397) 0.45 Mm Base Metal Thickness And 0.50Mm Total Coated Thickness, Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respects With Az 150 Gsm Smp Color Coated (20Mic Exterior Coat Of Silicon Modified Polyester Paint System Over 5 Mic Primer And 5 Mic Polyester Back Coat Over 5 Mic Primer) Incl. Fixing To Purlins With No 12X14X55Mm Mechanically Galvanised Hex Head Self Drilling Screws Of The Best Quality As Per As-3566 Class 3-4 Approved, Which Should Be Compatible To Be Used With Sheets. With Integral Washers And Epdm Seals Etc. Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. Plain Grill , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excludingfixingaccessoriessuchasnuts,Bolts, Fasteners Etc.). , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. Light Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Jet Black With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. ( Price Range 2000 To 2100 Rs Per Sq Mtr.) , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. ( Price Range 1550 To 1600 Rs Per Sq Mtr.) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm .80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Fixing 18Mm Thick Polished Black Granite Machine Cut For Kitchen Platforms, Counters, Window Sills, Door Frame, Urinal Partitions , Fascia And Similar Locations Of Required Size Of Approved Shade, Colour And Texture Laid Over 20Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing,Moulding And Polishing To Edge To Give High Gloss Finish, Etc. Complete At All Levels.( Price Range Rs.1500 To Rs.1700 Per. Sq.M ) , Providing 25Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 60 Cm L X45 Cm H X 15 Cm T , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand). 20 Mm Thick. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 (1 Cement: 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , 12 Mm Thick Cement Plaster 1:4 (1 Cement:4 Fine Sand) , 6Mm Thick Cement Plaster To Ceiling With 1:3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer , Extra For Plastering Done On Moldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws , Plugs And Priming Coat On Unexposed Surfaces Etc. 50X12Mm Size. , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 300X 16 X 5 Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Provided And Fixing 150 Mm Chromium Plated Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutters Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete. 200 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Window With 3 Tracks And 2 Shutters Sliding Window With Tobular Frame Ployster Powder If Thicness 75-80 Microns With Approved Standard Accessaries Such As Ball Beaing Rollers, Concealed Lock, 6Mm Thick Plain Clear Glass With Epdm Beading Etc. , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete. 10 Mm Dia , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete.12 Mm Dia , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead Extra For Dismantling Trusses, Rafters, Purlins Etc. Of Steel Work, For Every Additional Span Of One Meter Or Part Thereof Beyond 10 Mts. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead. Of Area 3 Sq.M. And Below , Dismantling Wood Work Of Area Below 40 Sq.Cm. Wrought Framed And Fixed In Frames, Other Frames And Trusses Including Stacking Of Material Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Nandi In Frp As Per Tender Drawing , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Laying 300X350X160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete) , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Saraca Ashoka , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Nyctanthes , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Filliciam Decipiens , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Dichotoma , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Millingtonia Hortensis , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Jacaranda Mimosifolia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neolamarckia Cadamba , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevetia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Alba , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Dual Flushing (Citren Nelson/ Similar)With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vacuum Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. (Excluding Handicap Toilets) , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430 X 260 X 350 Mm And 340 X 430 X 265 Mm Sizes Respectively With Pvc Automatic Flushing Cistern With Fittings, R.S. Or C.I. Brackets, Standard Size Galvanized Steel Flush Pipe And Spreaders With Brass Unions & G.I. Clamps Complete, Including Painting Of Cistern And Fittings, Cutting And Making Good The Walls And Floors Where Required. (A)One Urinal Basin With 5 Liters P .V .C. Automatic Flushing Cistern. , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required. Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws. Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Wall Mixer With 3 In 1 System With 115Mm Long Bend Pipe For Connection To Over Head Shower Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing C.P. Brass Towel Rail Complete With C.P. Brass Brackets Fixed To Wooden Cleats With C. P. Brass Screws. 750X20 , Providing & Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Cp Brass Screw , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed .110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed. 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating.110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door :110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door :110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door . 75Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Providing And Fixing R.P.V.C. Vent Cowl: 75Mm , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Cm2 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar. , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:.B) 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 32Mm Outer Dia. , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 15Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 40 Mm Nominal Bore . , Providing And Fixing Non-Return Valve Of Approved Quality :40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality .25 Mm Nominal Bore , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 25 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 32 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 40 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 50 Mm , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701;1996. 1000 Lit. Capacity , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70B50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Wall Mounted Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Complete. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (B) 10 To 40 A , Supply, Installation, Testing And Commissioning Of 3 Kva 1 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Square / Circular Max. 20 W Pendent Light With Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd10%, P.F. 0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Suspended Accessories Complete. , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii))
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
27.
Housing Urban and Rular Development #11068698 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres: As Directed By Engineer-In-Charge. Note :Stockpile The Top Layer Of Soil Of 200 Mm And Cover It For Reuse In Landscape (If Soild Is Fertile Or Capable To Make It Fertile), Soil Test To Be Performed From Icar Lab As Per Green Building Guidelines , Ordinary Rock 20% , All Kinds Of Soil 80% , Filling Available Excavated Earth (Excluding Rock) In Trenches Plinth, Sides Of Foundation Etc In Layer Not Exceeding 20Cm In Depth Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50Cm And Lead Up To 50 M And Lift Upto 1.5 Mtr. , Stone Solling Dumping Of Stone Including Cost Of Stone (In Horizontal On Level) , Providing And Laying Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 20 Mm Nominal Size) (Crushed) (Use Of Portland Pozzolana Cement Is Advised As Per Green Building Guidelines Or 25% Replacement Of Ordinary Portland Cement With Fly Ash By Weight Of Cement Used In Structural Concrete.) , Providing And Laying Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) (Crushed) (Use Of Portland Pozzolana Cement Is Advised As Per Green Building Guidelines Or 25% Replacement Of Ordinary Portland Cement With Fly Ash By Weight Of Cement Used In Structural Concrete.) , Cement Concrete Flooring 1:2:4 (1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry And Curing Complete, But Excluding The Cost Of Nosing Of Steps Etc. Complete.50 Mm Thick With 20Mm Nominal Size Stone Aggregate. , Reinforced Cement Concrete Work In Footing , Pedestal ,Columns , Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With M20 (1:1.5:3) (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Foundation, Footing Bases Of Column , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform. , Providing & Fixing Stabilized Mud Concrete Solid Blocks (Adobe) With 3% Cement, Masonry Up To Floor Five Level Including Hoisting And Setting In Position In Mud Mortar Using Approved Quality Mud With Carriage Of Material Complete. , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Seperately) First Class Deodar Wood , Providing And Fixing Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Seperately,All Complete As Per Direction Of Engineer-In-Charge.(Second Class Kail Wood 35 Mm Thick Shutter) , Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick.Second Class Kail Wood. , Providing And Fixing Dgu Float Glass 4 Mm Thick Glass Pane (Weighing Not Less Than 10 Kg/Sqm) , Cement Plaster (In Coarse Sand) 12Mm Cement Plaster Of Mix 1 : 4 ( 1 Cement : 4 Coarse Sand) (Ppc Or Cement With 25% Flyash Is Recommended As Per Green Building Guidelines.) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade On New Work (Two Or More Coats) Over And Including Priming Coat With Water Thinnable Cement Primer (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) Mud Colour , New Work (Two Or More Coats Applied @ 1.43 Litre/10 Sqm. Over & Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Preparing Newly Primed Wooden Surface For Painting By Way Of Filling Of Putty Sand Papering Rubbing Complete. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work. (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Providing & Fixing Finished Brass Hanging Type Floor Door Stopper With Necessary Screws Etc Complete. , Providing And Laying Vitrified Non Silipery Floor Tiles In Different Sizes (Thickness Tobe Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete I.E Size Of Tile 600X600 Mm ( Kajaria/Somany/Cera Or Any Approved Brand As Per Engineer In Charge) , Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 6 Mm Nominal Size) As Per Direction Of Engineer-In-Charge And Finished Smooth. , Flooring With Marble Stone Of Specified Thickness As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse Sand) Laid And Jointed With Grey Cement Slurry Including Rubbing, Polishing And Curing Complete With: , providing and Fixing 1St Quality Ceramic Glazed Wall Tiles Conforming To Is:15622 (Thickness To Be Specified By The Manufacturer) Of Approved Make In Colours, Shades Except Burgundy Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps, And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Course Sand) And Jointing With Grey Cement Slurry @3.3Kg/Sqm Including Pointing The Joint With White Cement And Matching Pigments Etc., Complete. , Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan) With 100 Mm Sand Cast Iron P Or Strap, 10 Litre Low Level P.V. C. Flushing Cistern Including Flush Pipe (Of Approved Make) Manually Controled Device (Handle Lever) Conforming To Is:7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required. (Note : It Should Have Flush Rate Of With Flush Rate Of 2/4 Litre Per Flush Or Less ) (Dual Flush 2/4L Wc Cistern With Bottom Inlet For Compact Back To Wall Rimless Toilet As Per Green Building Guidelines) , Orissa Pattern White Vitreous China W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. Jaguar/Cera Make , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C . .Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern Including Flush Pipe With Manually Controlled Device (Handle Lever) Conforming To Is:7231, With All Fittings And Fixtures, Complete Including Cutting And Making Good The Walls And Floors Wherever Requied: , W.C. Pan With Lsi Marked White Solid Plastic Seat And Lid. Jaguar/Cera Make , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Wallsand Floors Wherever Required : Single Half Stall Urinal With 5 Litre P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.I./M.S. Brackets, 15Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required: , White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps Jaguar / Cera/Hindware Make , providing and Fixing Of Mirrors Of Superior Glass With Plastic Moulded Frame(Of Approved Quality) And Of Required Size And Shape. With 6Mm Thick Hard Board Backing. Rectangular Shape 1500 X 450 Mm , Providing And Fixing Soil Waste & Vent Pipe (Prince Or Any Other Appoved Brand As Per Engineer In Charge , Pvc Pipe. 110Mm Dia (10 Feet Unit Length) , Pvc Pipe. 75Mm Dia (10 Feet Unit Length) , Pvc Bend 110Mm Dia , Pvc Bend 75Mm Dia , Pvc Tee 110Mm Dia , Pvc Tee 75Mm Dia , Pvc Collar 110Mm Dia , Pvc Collar 75Mm Dia , Pvc Trap 110Mm Dia , Pvc Trap 75Mm Dia , Pvc Socket 110Mm Dia , Pvc Socket 75Mm Dia , Pvc Door Junction 110Mm Dia , Pvc Door Junction 75Mm Dia , Providing And Fixing 3 Layer Thermex Pipe Pp-R (Poly Propylene Random Copolymer)Pipes Conforming To Is: 15801, Uv Stabilized And Anti-Microbial Fusion Welded, Having Thermal Stability For Hot And Cold Water Supply Including All Pp-R Plain And Brass Threaded Polypropylene Random Fittings. This Includes Testing Of Joints Complete As Per Direction Of Engineer-Incharge.Internal Work Concealed Fixing The Pipe With Clamps At 1.00 Meter Spacing Including Cutting Chases And Making Good The Wall Etc. , Pn-16 Pipe , 25Mm Od(Sdr-7.4) , Pn-16 Pipe , 32Mm Od(Sdr-7.4) , providing and Fixing Cp Brass Toilet Paper Holder Including Cost Of Wodden,Pvc,Play Etc. , Providing And Fixing Wall Mount Liquid Soap Dispenser Of Approved Brand , Providing And Fixing Accessories Of Standard And Quality Make Of Approved Manufacturer Including All Necessary Fixtures Required. , L-Drops For Room Door , T-Bolt For Room Doors / Windows , Handles For Doors & Windows , 15 Mm C.P. Brass Tap With Elbow Operation Lever , 15 Mm C.P. Brass 2 In 1 Tap Of Approved Quality Conforming To Is Standards , 15 Mm Nominal Bore C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms , C.P. Brass Extension Nipple (Size 15Mmx50mm) Of Approved Make And Quality As Per Direction Of Engineer-Incharge. , 15 Mm Nominal Bore Of Standard Back Type C.P. Brass Close Hole Basin Mixer Pillar Tap Including All Necessary Accessories Of Approved Quality And Make, Weighing Not Less Than 1.970 Kg. , High Water Pressure S.S Geyser Connection Pipe (2 Feet Long) Of Approved Quality And Make, , Supply Installation Testing And Commissioning Of Geyser 30Ltr Capacity Horizontally Mounted Of Approved Brand (Havells/Bajaj/Crompton Or Any Othet Approved Brand As Per Engineer In Charge Including All Fixtures , Bolts All Complete , 15 Mm Nominal Bore C.P. Brass Long Angle Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms , Providing And Installation Of Puf (Puf Insulated Tanks) Water Tank Capacity 1000 Ltrs Of Approved Brand (Syntex Or Any Other Approved Brand) As Per Direction Engineer Incharge , Supply And Installation Of High Quality Self Regulating Heat Tracer For Specialized Heating Solutions For Winterisation Of Water Pipeline Including All Accessories Complete Including Supply And Installation Of Circuit Control Panel With Rcbo Mcb ,Thermostat (0-120) Deg C, Power Connector-Two Way-6 Sq.Mm, W.P. Splice Connector,W.P. Tee Connector,End Seal,Mounting Kit-W.P. Jb,G.I. Pipe Strap 4,Al. Adhesive Tape Roll ( 50 Mm W X 20 M L),F.G. Adhesive Tape Roll (Danfoss Make Or Chromalox Any Other Approved Brand As Per The Direction Of Engineer-In-Charge) , Supplying And Fixing High Quality 32Mm Thick Nitrile Insulation Tube For Water Pipeline Of Approved Brand 2 Inch Size (Armaflex Class-O Armacell), Rock Wool Including Alumunium Duct Clading (Alumunium Sheet Guage Thickness = 0.46Mm To 0.71Mm )Of Approved Quality And Finish As Per The Direction Of Engineer In Charge , Providing Corrugated G. S. Sheet Roofing Including Vertical/Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Upto Any Pitch In Horizontal/Vertical Or Curved Surface)Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gram/M2 , Providing Of Fabricated Steel Roofing Truss, Purlins, Rafters, Posts, Plates Isa.65X65x6mm ,Isa.50X50x6mm, 40X40x6mm, Ismc 75Mm ,65Mm,50Mm,Plates 8Mm,10Mm Thick, Weather Boarding, Eves Boarding, Valley Angle Etc. Including Cutting Hoisting Fixing In Position And Applying A Priming Two Or More Coat Of Approved Steel Priming/Painting All Work Complete Job. Including Launching Of Trusses , Septic Tank , Earth Work In Excavation By Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 Min Width Or10sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms,Lift Upto 1.5M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , In All Kind Of Soil 30% , Ordianary Rock 30% , Hard Rock (Blasting Prohibited 40% , Stone Soling Hand Packed Including Carriage And Cost Of Stone , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 1:2:4(1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Leveling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20Mm Nominal Size) Upto Plinth Level And Curing Complete With: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Wall , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Slab , Cement Concrete Flooring 1:2:4 (1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry And Curing Complete, But Excluding The Cost Of Nosing Of Steps Etc Complete 50Mm Thick With 12.5 Mm Nominal Size Stone Aggregate. , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 13
Jammu And Kashmir View Result →
28.
Public Administrative Department #11014465 AOC
Tender for Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Providing And Fixing Stainless Steel Name Plate Of Size 6×8 Sq Inch Made Of 20 Gauge Sheet Including Engraved Name Of Area Representative Duly Painted Along With Ss Clamp Nut Bolt Etc As Required. , Fabrication, Supplying And Fixing Class B Galvanised Single Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipe With Tightening Bolts Complete As Required , Fabrication, Supplying And Fixing Class B Galvanised Double Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipes With Tightening Bolts Complete As Required. , Supply And Fabrication Of Pole Protection System Made Up Of 8 Swg Steel Wire Mesh Of Size 25Mm X 75Mm Rectangular With 50Mmx50mmx6mm Ms Angle Iron For Supporting The Mesh I/C Mv Danger Plate And Grounding The Protection System In Suitable Quality Of cement concrete Etc As Reqd. , Providing And Laying In Position M25 Grade Reinforced Cement Concrete Foundation Of Size 450 Mm(L) X 450 Mm Wide And 1000 Mm Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Rewinforcement Of Cold Twisted Bars Of 12 Mm Dia -960Mm Long (Approx.) - 8 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 1400 Mm (Approx.) - 6 Nos. (With 150 Mm Spacing) As Required With Supplying And Positioning Of 4 Nos Foundation Bolts Of Size 16 Mm Dia And 600 Mm Long, J Type I/C 2 Nos Template Anchor Plates Of Size 225 Mm X 225Mm X 3 Mm And Providing 63 Mm Dwc Hdpe Pipe For Cable Entry & Exit As Required For 5Mtr Pole , Fabrication, Supply & Erection Of 5.0 Mtr Height, Minimum 3 Mm Thick, Bottom Dia Of 130Mm & Top Dia Of 70Mm, Base Plate Of Size 225 X 225 X 12 Mm Thick Flange Mounted Hot Dip Galvanized Octagonal Pole Made From Ht Steel Plate, Window With Flash Cover With Full Vertical Window Cover At Appropriate Height From The Base Plate On Existing Cement Concrete Pedestal As Required. L/C Supplying And Fixing Of 6 Mm Thick Laminated Mounted Sheet Inside The Window And L/C Providing And Welding 3 Nos. Gi Strips 4 Mm Thick Of Suitable Length And Having Suitable Size Tapped Holes As Reqd, Terminal Block Suitable For 25 Sq Mm Conductor - 4 Nos. & Shorting Links On Din Channel L/C Providing And Fixing Din Channel Of Suitable Length, 6 Amp. Spmcb C Curve Characteristics, Earth Stud, Cable Support Clamp Suitable For Upto 4X25 Sqmm Cable. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is Code Etc As Required , Fabrication, Supplying, Installation, Testing, Commissioning Of 12 Metres Semi High Mast System With Its Accessories, Mast Shaft Shall Be In One Section, Hot Dip Galvanized 4Mm Thick(Single Dip) Inside & Out Sides &Sultable For Wind Velocity As Per Is 875 Part3.There Shall Be In Longitudinal Seam Weld Per Section And No Circumferential Weld. It Should Also Included Accessories For Seml High Mast Head Frame,2 Point Suspension System,5 X 2.5 Sqmm Copper Conductor With Steel Wire Rope 5Mm Dia. (7/19 Construction) Single Drum Winch ,Galvanized Lantern Carriage Arrangement Suitable For 4/6 Nos. Flood Light Luminaries Symmetrically And Its Control Gears Boxes And Lighting Finial, The Mast Shall Have Integral Type Manual Tool Mounted At The Base Compartment Of Its Raising And Lowering Operation With Foundation Bolts And Anchor Plate And Control Panel Housing Suitable Reinforced Cement Concrete (1:2:4) Shallow Foundation Of Size 1M(L) X 1M Wide And 2M Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Reinforcement Of Cold Twisted Bars Of 12 Mm Dia -2100Mm Long (Approx.) 16 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia 3700 Mm (Approx.) 13 Nos. (With 150 Mm Spacing) As Required With Positioning Of Foundation Bolts And Providing Dwc Hdpe Pipe For Cable Entry & Exit As Required For The Semi High Mast Considering The Safe Soil Bearing Capacity At Site As 10T/Sqm At 2Mts. Depth With All Material I/C 4 Nos S.P Mcb,1 No. Double Pole 16Amp. Mcb Etc As Reqd. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is. , Providing And Fixing Name Board Made Of Ms Sheet 90X60cm, 1Mm Thick With Frame Of Ms Angle 50X50x6mm, Two Diagonal Braces At The Back Of The Sheet Of Ms Flat 40X6mm, Total Height Of The Board Above Ground Level 2.40M, Length Of Legs Below Ground 0.30M Embedded In Cement Concrete Block 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size) 30X30x45cm Including Excavation And Removal Of Surplus Earth With In 50M Lead, Applying Priming Coat Of Approved Steel Primer, Painting With Synthetic Enamel Paint Of Approved Quality And Lettering With Enamel Paint Of Approved Colour (One Side) As Per Drawing/Direction Of Engineer-In-Charge , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection,Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 45 Watt , Led Flood Light, Powder Coated Pressure Die Cast Aluminum (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip-66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 100W
Contract Date: Jun 11, 2026 Contract Value : 40.54 Lakh
Local Bodies No of Bidders 3
29.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
30.
Defence #10861312 AOC
Tender For Repair/ Maintenance Of Ht Cables, Switch Gears And Relays Incl Connected Items Under Ge (W) Colaba.; 1 Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamberof HT 11KV, panel boardand carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge.(Note: spare parts shall be measured & paid seperately.) :-(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B)and HTtape and test with High Voltage(DC)and meggering before and after high voltage test complete.(ii) Inspecting/cleaning/overhauling of CT/PT chamberby checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CTs and insulatorsand HT Tape.(iii) Inspecting/cleaning/overhauling meteringchamberby checking ofentire wiring system, all meters, selector switches, control fuses and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system. 2 Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 3 Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare partssuitable for - VCB 11 KV , 630/800 Amps indoor type of Make Schnieder(PIX -MV)/ABB(VD4) /CG/AREVA(VMX) all as specified and directed by Engineer-in-Charge. 4 Isolating Contacts flat type 5 Vaccum InterupterVG2 6 Insulating Rod 7 Closing coil 110V /24V DC 8 Tripping Coil 110V /24V DC 9 Spring Charging Motor 110V-230V AC/DC 10 Breaker Auxiliary Switch 6NO +6NC 11 Motor Cut-off switch 12 Main Drive Shaft assembly 13 Trip Fork Linkage Assembly 14 Rachet Wheel 15 Pin for Rachet 16 Handle Block Assembly 17 Closing coilassembly without coil 18 Trip coilassembly without coil 19 Motor cutt offLever assembly 20 Trip Proper support assembly 21 Release lever 22 Pin for Release lever 23 Auxiary switch drive Assembly 24 Charging Pawl 25 Buffer for Spring 26 Over Rid Stop 27 Over Rid Stop Pin 28 24 Pin Plu and Socket Assembly 29 Bus Bar Spout Insulator with CC parts for R Phase 30 Bus Bar Spout Insulator with CCparts for Y Phase 31 Bus Bar Spout Insulator with CC parts for B Phase 32 Circuit Spout Insulator with CC Parts 33 3Phase Spout Insulator assembly Bus bar /Circuit side. 34 Half Collar (Pair) 35 Raising and lowering Handle 36 TNC Switch,16Amps Recom 37 Ammeter,digital type,DM3110 Schneider 38 Voltmeter,digital type DM3210 Schneider 39 Multifunction meter digital typeEM6400NG Schneider 40 Indicating Lamps 24/110V DC LED type 41 Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts ACand replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately) 42 Material and labour for painting of HT VCBcapacity 250/350MVA,11KV, 400/630/800Amps, with onecoat of synthetic enamel paint over a coat ofred oxide primerafter cleaning, scraping, and filling ofcavitiesfor out side surface and in side surfaceof VCB and writing the details such as MES No/ SM No etc on the new metallic plate of size 30x15cm and fixng the metallic plate firmy on VCBall as specified and as directed by Engineer-in-charge. 43 S&F, testing commissioning ofcurrent transformer 50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec for 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps, panel board complete all as directed and specified by Engineer-in-Charge. 44 T&P for Testing of primary injection by artificialloadthroughCT’s, on each multiple settingofovercurrent & earth fault relay, testing polarities, ammeter and selectorswitchandasdirected by Engineer-in-Charge. 45 T&P for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete. 46 Repair/Overhauling Indoor type, 11 KV, SF 6, RMU Panel and carrying with following and all as specified and directed by engineer in Charge.Note :- (i) Including fixing ofspare parts to function RMU smoothly and rate to be included.Notes :-Spare parts and SF6 Gas will be measured and paid separatly. (i) Inspecting/overhauling of Manual/motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, Small Cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply multi grease lubricant to function smoothly.(ii)Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii)Inspecting / overhauling /cleaning and inspecting insulators, Gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Inspecting of Gas SF6 leakage and Re filling SF6 gas as required and all as directed.(v) Overhauling/testing of Metering Panel with PT(vi) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete.(vii) Cleaning all busbar by rubbing and by CRC liquid cleaner.(viii)Spraying two coat of anti track paint on CTs.(ix) Applying insulating boots for busbar and cables. (x) Supply and fixing all missing nut bolts for panels. 47 S&F 11 KV, SF 6,RMU Panel Spring Charging Motor, with complete mechanisim 230/110/24 Volts of existing make. 48 S&F 11 KV, SF 6,RMU Panel SF 6 Gas filling up to the indication mark complete all as specified and as directed. 49 Repair/ MaintenanceBattery Charger Circuit 240 V AC to110 V DC 20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed. 50 Repair/ MaintenanceDC to DC Converter 110 V DC to 24 Volt dc20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed 51 S&F battery SMF EP 100-12 (12V/100AH) complete all as specified and as directed 52 Dismantling old burnt Heaters and Supply Fixing Space Heater 80 Watt capacitysuitable for VCB,s /OCB in existing panel including hard ware,wiringand all as directed. 53 T&P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 54 T&P for route tracing ofHT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 55 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 56 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240 sqmm to 300 sqmm all as specified. 57 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 58 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240sqmm to 300 sqmm all as specified. 59 Supply, Installation, testing ON LOAD & commissioning of Compact motor protection relay flush mounting with display MM-10 with 110-240V AC/DC aux supply, having following protections with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system making good to the disturbed surface all as specified and directed.(a) Thermal over load and short circuit . (b) Earth fault and phase loss, unbalance, phase reversal.(c) Prolong starting, locked rotor and last trip data recording. 60 Supply, Installation, testing & commissioning of Under Over Voltage relay single phase system voltage 20-110 Volt AC/DC with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system including making to the disturbed surface all as specified and directed. 61 Material and labour for loading into truck of old OCB/VCB with the help of Crain and shifting from site to store/ substation premises and unloading complete all as specified and directed. 62 Material and labour Disconnecting, dismantling & restablising the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 63 Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out completein soft/loose soil all as specified. 64 All as perabove item No.63.00 above but in hard/dense soil. 65 Excavationin trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in soft disintegrated rocks/road cutting/RCC/PCC complete all as specified and directed. 66 Supply and providing sand/stone dust for sand cushioning for cable protection orfilling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thicknesswill be measured. 67 Supply and providingunreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) ofsizes Class HVPtype I with peak, flat size 300x180x40 mm putting adjecent to each other as specified. 68 Supply and laying tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed. 69 Returning,filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified. 70 Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil 71 Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed. 72 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 240 sq. mm X 3 core all as specified and as directed. 73 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed. 74 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm X 3 core all as specified and as directed. 75 Manufacturing, supplying and fixing at various sub stations for SOP (Standard Operating Procedure) for VCB/ RMU Operation on farme board of size 600 mm x 900mm having fully covered by suitable plain glass as approved . Letter,symbols, MES Logo ,borders etc.on A-1 Size paper all as required colour scheme in all respects as per direction of Engineer-in-charge. 76 T&P for fault finding, confirmation and route tracing on LT cables of any size and any length with fault detective machine by thumping method and suitable high voltage and all as and directed by Engineer-in-charge. 77 Material & labour for cable jointing kit, in repair, for LT 1.1 KV grade cable for straight through joint M-Seal type for underground PVC/XLPE armoured heavy duty cable aluminum conductor of size3.5/4 core 50 Sqmmcomplete including testing & commissioning complete all as specified and directed. Make: XICON/Raychem/3M/Mahindra and Mahindra. 78 All as per aboveitem No 77.00 herein before but cable 3.5 core 70 Sq mm 79 All as per aboveitem No 77.00 herein before but cable 3.5 core 95 Sq mm 80 All as per aboveitem No 77.00 herein before but cable 3.5 core 120 Sq mm 81 All as per aboveitem No 77.00 herein before but cable 3.5 core 185 Sq mm 82 All as per aboveitem No 77.00 herein before but cable 3.5 core 240 Sq mm 83 Material & Labourfor repairs/ Overhauling/Servicing to ExistingLT electric panels by takingshut down from appropiate authority includingT&P for Attending Faults/Trippings and rectifieng /repairingthe faults in HT/LT Panels Boards/Capacitor Panels Boaeds/ MCCBs/ACBs /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut boltsand all as specified and directed by Engineer-In-Charge. (i)Tightning the loose connectionsand cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as pproved colourandtesting the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed .(Note : MCCB,ACB, measured and paidseparately under relevant items of this schedule.) 84 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 240 Sqmm to 300 Sqmm x 3.5 core complete all as specified and directed by Engr-in-charge. 85 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 240Sqmm x 3.5 corecomplete all as specified and directed by Engr-in-charge. 86 Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhaulingof spring drive mechanism, coil, auxiliary switch includingsetting of over loadcoil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspectingmale and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective positionandtesting complete all as specified and directed by Engineer-in-Charge. 87 Dismantling of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare partssuitable for -ACB 415V , 630 to 1200Amps Amps indoor type of Make ; Havells/ Schneider/IndoAsian/HPL/Legrand/C&S all as specified and directed by Engineer-in-Charge. 88 Shunt Trip Device 89 Closing coil assembly 90 Mismatch Prevention Device 91 Moving contacts assembly 92 Fixed Contact assembly 93 Auxiliary Switch 94 Arc chut with hardware 95 Current Transformers 630A/5A. 96 Current Transformers 800A/5A 97 Current Transformers 1200A/5A 98 Dismantlingof old damaged Meters and Supply & fixDigital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:AE/MECO/ Elmeasure. 99 Dismantlingof old damaged MetersSupply & fixing Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type andall as specified and directed. Make:AE/MECO/ Elmeasure. 100 Dismantling of old damaged halogen fitting Supply & fixing in repairs 500 watt Incandescent/ GLS lamp halogen Lamps with holder with aluminum cover 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 101 S&F of Room Heater 1000 Watt coil type in substation to avoid moisture in HT installation room complete all as specified and directed by Engr-in-charge. 102 Dismantling of old damaged Lamps and Supply & fixing in repairs 200 watt Incandescent/ GLS lamp 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 103 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel as required for retrofit after wiring work complete all as specified & directed. 104 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel,SMARTCOMN EMS Energy Management System software with multiple features suitable for minimum 10 meters at existing dashboard/ computer and shall capture and provide following data for 12 months peroid:1) 30 min instantaneous data from all the meters for seven parameters- cumulative Energy, Power, Current, Voltage, Power factor and frequency. 2) Multiple combination of device and parameters for analysis and monthly and quaterly billing survey dattion a for cumulative energy and max demand.3) Specific Energy Consumption (SEC) Report and assess to features defined by user levels.4) Monitor ON, OFF, TRIP, Ready to close status of circuit breaker through E&As UNCO Module with on premise solution. 5) Provision for Breaker ON & TRIP counter, Last 20 trips date & time6) Email and SMS notification & Excel reports with charts. 105 M&L for Maint of MQTT GPRS Converter Outdoor (LoRa) Long Range Communication Accumulator suitable for communicating with multifunctional digital Meter with LoRa communication protocol and the data transfer to the software complete all as required on existing ground position as specified and directed. 106 M&L for Maintand recharge topup for 12 months peroidof 4G/5G Router all asrequired as on existing ground position including necessary data cable (low impedance ) suitable to existing ground position including necessary data cable (low impedance) suitable to transmit data of energy meter port and CAT-6 (Patch Cord) all as directed by Engr-in-Charge. 107 M & L and fabrication work with Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and diredted by Engr-in-charge. 108 M&L electrical earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly inground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level, connected toGI earth strip 32mm x 6mmearth leadby means of bolts,nuts and washers of galvanised iron, earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board/panel board , all as specified and shown in MES schedule Electrical Plate No-5 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, RCC 1:2:4 type B1, 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoaldust, salt, funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed. Note : Value of earth resistance shall not be more than 2 Ohm. 109 M&L in repairs galvanised iron strip 32x6mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof ofhigh rise bldg and as required by saddles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop all as specified and directed by the Engineer-in-Charge. 110 Supply and fixing substation insulation rubber floor mats not less than 2.5 mm thickness suitable for operation on 11 KV panels confirming to IS 15652 : 2006 all as specified and directed by Engineer-Incharge.
Contract Date: Apr 27, 2026 Contract Value : 32.04 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
31.
Public Administrative Department #10852137 Technical Bid
Tender For Supply, Installation And Commissioning Of Machinery For Shree Saibaba I.T.I, Shirdi. Tools, Equipment, Instrument List (As Per New Syllabus -All Trade) 1) Trade- Fitter , Pipe Cutter 6 To 25Mm Wheel Type Make - Stanley/ Ingco/Taparia / Bharat /Jk , Pipe Bender Spool Type Up To 25.Mm With Stand Manually Operated Make - Beekay / Breeze /Indar/ Voltz /Stanley , Ss And Sc Centre Lathe (All Geared) With Minimum Centre Height 6/150 Mm & Center Distance 1000 Mm Along With 3, 4 Jaw Chuck, Auto Feed System, Coolant Arrangement, Lightening Lamp, Taper Turning Attachment, Safety Guard & Standard Accessories. Make - Kirloskar / Hmt / S Micrometric , Drilling Machine Pillar Sensitive 0-20 Mm Capacity With Swivel Table Motorize With Chuck & Key Make - Panchal / Skp / Eifco /Makita , Drilling Machine Bench Sensitive 0-12 Mm Capacity With Motorize With Chuck & Key Make -Panchal /Skp / Eifco / Makita , Compressor Unit:- Suitable For Pressure - 8 Bar, Delivery-50Lpm Or More, Receiver Capacity-24 Liters Or More, 250V,50 Hz, With Pressure Regulator And Water Separator Make - Fuji / Air Master/ Elgi/Ingersol Rand , Pneumatic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories. Single Acting Cylinder- Max. Stroke Length 50Mm, Bore Dia 20Mm - 1 No. Make - Extreme / Genitic / Parker / Koganei , (Ii) Double Acting Cylinder - Max.Stroke Length 100Mm, Bore 20Mm, Magnetic Type - 1 No. , (Iii) 3/2 Way Valve Manually-Actuated, Normally Closed. - 2 Nos. , (Iv) 3/2- Way Valve Pneumatically-Actuated Spring Return 1 No. , (V) One Way Flow Control Valve - 02 Nos. , (Vi) 5/2-Way Valve With Manually-Operated Switch-1No. , (Vii) 5/2 Way Valve-Pneumatically Actuated Spring Returns. , Viii) 5/2 Way Pneumatic Actuated Valve Double Point-1 , (Ix) 3/2 Way Roller Lever Valve Direct Actuation Normally Closed. - 02 Nos. , (X) Shuttle Vale - 01 No. , (Xi) Two Pressure Valve (And) - 01 No. , (Xii) Pressure Gauge 0-16 Bar - 01 No. , (Xiii) Manifold With Self-Closing Nrv-6 Way - 01 No. , (Xiv) Push Button Station For Electrical Single Point With 3 Illuminated Momentary-Contact Switch (1No + 1 Nc) And 1 Illuminated Contact Switch (1No+1Nc), Contact Load 2 A.- 01 No. , (Xv) Relay Station- With 3 Relay Each With 4 Contact Set (3No + 1Nc) Or Change Over Type, 5 A. - 01 No. , (Xvi) 3/2 Way Single Solenoid Valve With Led - 01 No., , (Xvii) 5/2 Way Single Solenoid Valve With Manual Override And Led - 01 No. , (Xviii) 5/2 Way Double Solenoid Valve With Manual Override And Led - 01 No. , (Xix) Power Supply Unit - Input Voltage 85-265V Ac, Output Voltage; 24V Dc, Out Put Current-Max.4.5A., Short Circuit Proof. - 01No. , (Xx) Profile Plate, Anodized Aluminum. 1100X700Mm. With Carriers, Maintenance Of Punting Frames And Mounting Accessories (Tube Fitted On To The Pneumatic Workstation. - 01 Set , Pneu, Matic Workstation With 40 Square Mm Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handle And Individual Locks, On Metallic Full, Panel Drawer Slide , (1) Work Table Size 1200Mm (L) X900Mm (W) X900Mm. (H), With Four Custard Wheel Including Two Lockable Wheel At The Front Side. , Drawer Size - L 460 Mm X W 495Mm. X H 158Mm. Each And Overall Size Of Drawer Unit (Apex) L 470Mm X W 495Mm X H 825Mm , (3) Drawer Slide Height (Apex) 85Mm. , Carrier For Mounting Components, Such As Pb & Relay Boxes. Cut Section Model For Pneumatic Components. , Hydraulic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories Make - Hitachi / /Tecno / Power Tech / Cad Mech Engineering / Equator Hydraulic , 1) Hydraulic Power Pack: - With (1) External Gear Pump Having A Delivery Rate Of 2.5 Improvement (Apex) (A) 1400 Rpm Operating Pressure 60 Bar, Coupled To A Single-Phase Ac Motor (230V Ac) Having Starter Capacitor And On/Off Switch And Overload Protection, , 2) Pressure Relief Valve Adjustable From 0-60 Bar , 3) Oil Reservoir, 5 Liters Capacity Having Sight Glass, Drain Screw, Air Filter And P And T Ports. - 01 No. , Ii) Pressure Relief Valve Pilot Operated - 01 No. , Iii) Drip Tray, Steel 1160Mmx760Mm. - 01 No. , Iv) Pressure Gauge Glycerin- Damped, Indication Range Of 0-100 Bar. - 01 No. , (V) Four-Way Distributor With Five Ports, Equipped With A Pressure Gauge. - 01 No. , (Vi) Double Acting Hydraulic Cylinder With A Control Cam, Piston Diameter 16Mm.,Piston Rod Diameter 10Mm,Stroke Length 200Mm. - 01 No. , (Vii) Suitable Weight For Vertical Loading Of Hydraulic Cylinder - 01 No. , (Viii) Mounting Kit For Weight For Realizing Pulling And Bushing Lead. - 01 No. , (Ix) 3/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (X) 4/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (Xi) 4/3 Way Directional Control Valve. Closed-Center Position, With Hand Lever Actuation - 01 No. , (Xii) Non Return Valve - 01 No. , (Xiii) Pilot Operated Check Valve Pilot To Open -01 No , (Xiv) One Way Flow Control Valve With Integrated Check Valve. - 01 No. , (Xv) T-Connector With Self-Sealing Coupling Nipples (2 Nos.) And Quick Coupling Socket (1 No.) - 02 Nos. , (Xvi) Profile Plate: - Anodized Aluminum, 100X700Mm With Carriers, Mounting Frames And Mounting Accessories (To Be Fitted Onto The Hydraulic Work Station. - 01 Set , Hydraulic Work Station With 40 Square Mm. Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handles And Individual Locks, On Metallic Full Panel Drawer Slide. , (1) Work Table Size (Apex) L1200Mm. X W900Mm. Xh900Mm. With Four Castor Wheel Including Two Locale Wheel At The Front Side. , Drawer Size (Apex) L460 Mm X W495Mm. X H158Mm Each, And Overall Size Of Drawer Unit (Apex). L470Mm X W495Mm. X H825Mm. , (3) Drawer Slide Height (Apex) 85Mm. Cut Section Models For Hydraulic Components. , D.C. Shunt Generator With Control Panel,2.5 Kw, 220V & 3 Phase Squirrel Cage Induction Motor, 5 Hp,440V With Control Panel & Star Delta Starter 1) Dc Generator Make - Crompton / Bharat Ele. Motor/ Kirloskar / Electronech / Power Way Systems 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor-Generator (Ac To Dc) Consisting Of : Squirrel Cage Induction Motor With Star Delta Starter And Directly Coupled To Dc Shunt Generator And Switch Board Mounted With Regulator, Air Breaker, Ammeter, Voltmeter, Knife Blade Switches And Fuses, Set Complete With Case Iron And Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Induction Motor Rating ;- 7.5 Hp, 415V, 50 Cycles, 3Phase Dc Shunt Generator Rating ;- 5Kw,440V (Output Voltage Varies 110-440V) 1) Dc Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Series Motor Coupled With Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Shunt Motor Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Compound Motor With Control Panel Including Spring Balance Load, Starter And Switch- 2.5 Kw, 220Volts 1) Dc Compound Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor Generator(Dc To Ac) Set Consisting Of - Shunt Motor With Starting Compensator And Switch Directly Coupled To Ac Generator With Exciter And Switch Board Mounted With Regulator, Breaker, Ammeter, Voltmeter Frequency Meter, Knife Blade Switch And Fuses Etc. Set Complete With Cast Iron Bed Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Shunt Motor Rating: - 5Hp, 440V, A.C., Generator Rating: - 3-Phase, 4-Wire, 3 Kva, 400/230 Volts, 0.8Pf, 50Cycles. 1) Dc Shunt Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) A. C. Generator Make - 1. Kirloskar 2. Crompton, 3. Siemens / Abb 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Squirrel Cage Motor With Star Delta Starter And Triple Pole Iron Clad Switch Fuse With Mechanical Loa,5 Hp,3-Phase ,415 Volts, 50 Hz 1) Ac Squirrel Cage Motor Make - 1. Crompton, 2. Siemens, 3. Hindustan Elec. Motor /Abb / Siemens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Phase-Wound Slip Ring Motor With Control Panel ,Starter And Switch 5 Hp, 440 V, 3-Phase, 50 Hz 1) Ac Phase-Wound Slip Ring Motor Make - 1. Crompton, 2. Siemens, 3. Havells Motor /Abb / Simens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard , Universal Motor With Control Panel, Starter/Switch 240 Volt, 50 Hz, 1 Hp 1) Universal Motor Make - 1. Crompton Greaves, 2. Hindustan Motor /Agni Motors / Integrated Elect Construction Of 3. Siemens / Bosch Power Tool 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Synchronous Motor With Control Panel Accessories. Like Starter, Excitation Arrangements,-3 Phase, 3 Hp, 440V, 50Hz, 4 Pole, 1) Synchronous Motor Make - 1. Kirloskar, 2. Crompton, 3. Siemens / Abb 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor /Igbt Controlled D.C. Motor Drive With Tacho-Generator Feedback Arrangement 1 Hp (Complete Set) 1)Thyristor /Igbt Controlled D.C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb / Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor / Igbt Controlled A.C. Motor Drive With Vvvf Control 3 Phase, 2 Hp (Complete Set) 1) Thyristor /Igbt Controlled A .C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Transformer, Core Type, Air Cooled, 1 Kva , 240/415 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Technovision Energy /Servokon /Sahara , Three Phase Transformer, Shell Type, Oil Cooled With Delta / Star 3 Kva , 415/240 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Servocon / Kay Pee , Electrical Machine Trainer - Suitable For Demonstrating The Construction And Functioning Of Different Types Of Dc Machines And Ac Machines (Single Phase And Three Phase). Should Be Fitted With Friction Brake Arrangement, Dynamo Meter, Instrument Panel And Power Supply Unit. 1) Dc Machines And Ac Machines Make - 1. Crompton 2. Kirloskar, 3. Siemens / Kitek Technology /Anshuman Tech 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Diesel Generator Set With Change Over Switch, Over Current Breaker And Water/ Air-Cooled With Armature, Star-Delta Connections Ac 3 Phase, 7.5 Kva, 415 Volt Or Higher Rating Make - 1. Kirloskar 2. Cummins 3. Mahindra Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Pillar Electric Drill Machine Motorized 12-20Mm. Capacity, 1 Hp,440V,3 Phase, Induction Motor With Dol Starter, Bench Type 1) Electric Motor -1. Crompton 2. Kirloskar 3. Siemens 2) Drill Machine Piller - 1. Prakash Engitech Pvt. Ltd. 2. Sri Vigneshwara Machine Tools. 3. Yogi Machine Tools / Itco Engg/ Liberty Metal /Jeet Machine , A.C. Series Type Motor With Control Panel 1 Hp, 240 V, 50 Hz 1) A.C. Series Type Motor Make - 1. Crompton 2. Kirloskar,3. Siemens /Abb / 2) Control Panel- Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Capacitor Motor With Control Panel , Starter Switch 1 Hp 240 Volt 50 Hz 1) Single Phase Capacitor Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Kirloskar 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Manual Motor Coil Winding Machine - With Step Arbour Make - 1. Chawla And Chudhari Trading Co. Pvt 2. Bgi Tools And Machine 3. Shree Esha Winding Technology / Sigva / Signatt / Heaven , Ceiling Fan Coil Winding Machine - 250V,50Hz, 1- Phase With Speed Control Make - 1. Bharat Machine Tools Ind. 2. Nishan Electric 3. Jangir Engineering Work / Kisan Engg / Nilkanth Electric , Primary Current Injection Set 220V,50Hz, 1-Phase,Output Current-200A(Min) With Timer Make - 1. Sb Electro Tech. 2. Pragati Process Controls, 3. Scope T&M Pvt / Udeytaj Electric / Motwane /Kpm Engg , Stepper Motor With Digital Controller Make - 1. Ajanta Export Industries. 2. Anubhuti Power System 3. Bombay Electronics 4. Siemens 5. Schneider Elect 6. Abb , Shaded Pole Motor Fractional Hp, With Control Panel 240V 50Hz 1) Shaded Pole Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Rexnord 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , D.C. Compound Generator With Control Panel Including Fitted Rheostat, Voltmeter, Ammeter & Breaker, 2.5 Kw, 220 V & 3 Phase Squirrel Cage Induction Motor 5 Hp, 440 V With Control Panel & Star Delta Starter. Make - Dc Compound Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar / Powerol 3- Phase 1) Induction Motor Make - 1. Crompton 2. Umiya Trading Company 3. Envirotech Engineers 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Used D.C. Generator Series, Shunt & Compound Type For Overhauling Practice. Make - 1. Crompton, 2. Bharat Ele. Motor 3. Kirloskar , Smart Meter 1- Phase - Smart Energy Meter 3 - Phase - Smart Energy Meter Make - 1.Genus Power Infrastructures Ltd 2.Hpl Electric & Power 3.Elmax India / L&T Electric , Ev Charger 3 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronic / Servotech Power System , Ev Charger (Home) 1 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronics , Work Shop Main Control Panel With Voltmeter Indicator Ammeter Indicator 1. Maintenance 125 A 440V 2. Output Main Switch - 16A - 08 , 32A - 08 63A - 02 Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , D C Control Panel Income - 440V Ac Output -12V ,24,110V, 240V, 440V, Dc With Indicator Voltammeter Ampire Meter Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , Welding Transformer With All Accessories ( 400A, Ocv 60-100 V, 60% Duty Cycle) Make - Miller / Ador / Esab / I Bell , Welding Transformer (Or) Inverter Based Welding Machine With All Accessories (300A , Ocv 60 - 100 V, 60% Duty Cycle) Miller / Ador / Esab / I Bell , D.C Annual Rate Contract Welding Rectifiers Set With All Accessories (400 A. Ocv 60 - 100 V, 60% Duty Cycle ) Make - Miller / Ador / Esab / Vigor , Gmaw Welding Machine 400A Capacity With Air Cooled Torch, Regulator, Gas Preheater, Gas Hose And Standard Accessories Miller / Ador /Esab / Kemppi , Ac/Dc Gtaw Welding Machine With Water Cooled Torch 300 A, Argon Regulator, Gas Hose, Water Circulating System And Standard Accessories. Miller /Ador / Esab / I Bell / Lincoln , Air Plasma Cutting Equipment With All Accessories, Capacity To Cut 12 Mm Clear Cut Make -Miller / Esab / Hypertherm / Rali Wolf / Technocard Plasma , Air Compressor Suitable For Above Air Plasma Cutting 15 Kw System Two Stage Compressor. 225 Ltr. Auto Cut Tank Cap. 80 -100 Psi Make -Elgi /Allas Capco / Ingersoll Rand / Premier , Auto Darkening Welding Helmet Make -L&T / Bell / Esab / Miller , Spot Welding Machine To 15 Kva With All Accessories Make - Ador / Esab/Artech / Micro Weld , Portable Gas Cutting Machine Capable Of Cutting Straight & Circular With All Accessories Make - Esab/ Pug Nm / Koike India /Ador / Pentagon , Pedestal Grinder Fitted With Coarse & Medium Grain Size Grinding & Wheel Dia-300Mm. Make -Elmaco / Bosch / Vijay Foundry Equipment , Bench Grinder Fitted With Grain Size Silicon Carbide Green Grinding Wheel Dia 150Mm Make - Elmaco / Bosch / Dewalt / Stanley Corded , Power Saw Machine 18 Hp-300 Blade Size - 450 Mm Make -Bosch / Dewalt / Hitachi / Kmi / Atlas Mochal , Portable Drilling Machine Capacity 6Mm. Make - Bosch / Dewal/ Hitachi , Oven Electrode Drying 0To 350C 10Kg Capacity Make - Ador /Arcon /Senso Heat , Die Penetrating Testing Kit. (Machine) Make - Esab / Dubi-Chek / Aerol / Magnaflux , Magnetic Particle Testing Kit. Make -Esab / Canmay /Mag Flux / Magnaflux / Magkraft , Wedding Simulators For Smaw,Gtaw,Gman (Optional) Make - Krb Electronic Soln Rewabsi / Simbott , Water Cooled Induction Welding/ Brazing Machine 200-250 Amp., Induction Coil Length 3 Inch And 2.5 Inch Make - Esab /Micro Tech Induction /Foster Induction /Vel I Braze Snapet / Welding World , Plastic Welding Machine With Hot Air Gun Temp. Display, Variable Temp., Pe, Pp& Pvc Sheet Or Pipe Welding Control With Stand. Accessories. Make - Esab / Leister / New Vimco Ltd /Ajanta Ultra Plast / I Bell / Vormik Vr/Branson Ultrascnies , Ag4 Grinder 100 Mm Dia Make - Dewalt / Bosch /Jk Supper / Metabo , Portable Abrasive Cut Off Machine 107 Mm Dia Make - Dewalt / Bosch / Ingco Hikoki /Mangalam / Century / Emboro , Hand Shearing Machine Cp Cut 6 Mm Sheet & Flat Make - Shakti / Vmt/ M.S. Machine Tools/Tl Pathak Group , Laser Cutting Machine Portable 50 Mm Laser Make - Esab / Toumf / Amada / Parag Weld Algo Laser/ Auto Mstack/Crealrty , Lathe S.S. & S.C. (All Geared Head Stock) With Minimum Specification As: 150Mm Centre Height To Admit 750Mm Between Centres, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 150Mm., 3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Travelling Study, Face Plate, Driving Plate, 4 Way Tool Post, Quick Change Gear Box For Metric Or British Threads, Live And Dead Centre With Taper Turning Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar /Hmt/ S Micrometric , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Between Centers, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 250Mm.,3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Traveling Steady, Face Plate, Driving Plate 1-Way Tool Post, Draw In Type Collets Set Up To 25 Mm, 0.5 Mm Relieving Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar / Hmt / S Micrometric , Grinding Machine Pedestal Type D.E.200Mm. Dia. Wheel With Wheel Guard And Vision, Motor Capacity - 0.75 Kw. Make - Elmaco / Bosch / Ingco , Cnc Lathe/Cnc Turn Centre Make - Bfw / Moriseiki / Makino , 1) Machine Capacity A. Swing Over Bed - 350 Mm Or Higher B. Turning Diameter - 135 Mm Or Higher C. Distance Between Centers - 250 Mm Or Higher D. Maximum Turning Length - 200 Mm Or Higher E. Slant Angle (Bed Or Saddle) -30 Degrees To Horizontal Or Higher F. Cast Iron Grade For Bed And Saddle - Grade 25 Or Equivalent G. Machine Weight Net - 1500 Kg Or Higher , 2) Spindle A. Spindle Nose -A2-4 / A2-5 B. Bore Through Spindle - 35Mm Or Higher C. Maximum Spindle Speed - 4000 Rpm Or Higher D. Spindle Power, Continuous - 3.7 Kw Or Higher E. Minimum Spindle Speed @ Full Power - 1200 Rpm, Or Lower F. Type Of Drive - Ac Servo Spindle Motor (Digital) G. Chuck Size -135 Mm Or Higher. Chuck Type H.3-Jaw Hydraulic, Hydraulic Power Operated I. Spindle Bearing Class - P4 Class J. Front Bearing Dia. (Id) - 60 Mm Or Higher , 3) Axes A. X - Axis Travel - 100 Mm Or Higher B. Z - Axis Travel -200 Mm Or Higher C. Programmable Feed Rate- X & Z -10 - 10000 Mm/Min D. Minimum Programmable Command -X & Z - 0.001 Mm E. Rapid Traverse - X & Z - 20 M/Min Or Higher F. Type Of Drive - X & Z - Ac Servo Motor G. Motor Torque - Z Axis - 3Nm Or Higher H. Motor Torque - X Axis - 3Nm Or Higher With Brake I. Ball Screw - Z & X Axes (Diameter X Pitch) - 25 X 10 Mm Or Higher J. Ball Screw Finish - Z & X Axes - Hardened And Ground K. Ball Screw Class- Z & X Axes - Pre-Loaded With C3 Or Better L. Guide Way Type - Z & X Axes - Antifriction Linear Motion Guide Way M. Guide Way Size - Z & X Axes - 25Mm Or Higher N. Guide Way Precision - Z & X Axes - P Class , 4) Turret A. Bi-Directional Tool Turret - Electromechanical/Servo/Hydraulic B. No. Of Tools - 8 Nos. Or Higher C. Tool Shank Size - 20 X 20 Mm Or Higher D. Maximum Boring Bar Diameter - 25 Mm Or Higher , 5) Tail Stock A. Quill Diameter - 65 Mm Or Higher B. Quill Stroke - 70 Mm Or Higher C. Quill Taper- Mt-4 Or Higher D. Quill Actuation - Hydraulic E. Tail Stock Base Travel Manual - 150 Mm Or Higher F. Thrust (Adjustable) - 300 Kg For Higher , 6) Coolant/Lubrication/Hydraulic A. Coolant Tank Capacity - 100 Liters Or Higher B. Coolant Pump Motor - 0.37 Kw C. Coolant Pump Out Put - 20 Lpm Or Higher D. Lubrication Type - Automatic Centralized Lubrication E. Lubrication Tank Capacity 3 Liter Or Higher F. Hydraulic Pump Discharge - 8 Lpm Or Higher G. Hydraulic Tank Capacity - 30 Liters Or Higher H. Hydraulic System Pressure Maximum -30 Bar Or Higher , 7) Accuracy As Per Iso 230-2 A. Positioning Accuracy X & Z Axes - 0.012Mm B. Repeatability X & Z Axes - ± 0.007Mm C. Geometrical Alignment - Iso 13041-Part 1 D. Accuracy Of Finish Test Piece - Iso 13041-Part 6 , 8) Cnc System A. Control System - Fanuc / Siemens B. System Resolution - 0.001 Mm C. Motors & Drives - Compatible With Cnc Controllers Mentioned Above D. Tool Number Display - On Machine Operator Panel E. Machine Control Panel - Feed Rate, Spindle Speed Override Knob F. Mpg (Manual Pulse Generator) - On Machine Operator Panel G. Cnc Features - Graphic Simulation, Programming Help, Tool Offsets, Mdi, Absolute/ Incremental Positioning, Pitch Error Compensation , 9) Power Source A. Mains Supply (± 10 %) - 415 V, 3 Ph., 50Hz B. Total Connected Load Requirement - Approx. 15 Kva , 10) Standard Equipment A. Voltage Stabilizer 15 Kva B. Air Conditioning Unit For Electrical Cabinet - 1 No. Backup Cd For Plc Ladder Logic - 1 No. D. Machine Lighting - 1 No. E. Levelling Pads And Jacking Screws - 4 No. F. Operation Manual - 1 No. G. Maintenance Manual - 1 No. H. Installation Kit - 1 No. I. Maintenance Tool Kit - 1 No. J. 6 Rack Trolley (Size 25X22X45) With Lock - 1 No. K. Machine Guarding With Safety Compliance - 1 No. , 11) Makes Of Critical Machine Tool Components A. Linear Motion Guide Ways - Hiwin/Thk/Pmi/Star B. Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C. Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D. Turret - Pragati/Baruffaldi/Sauter/Duplomatic E. Hydraulic Chuck & Cylinder - Gmt/ Kitagawa / Airtech /Pragati / Rohm F. Hydraulic Power Pack - Yuken/Fluid/Rexroth G. Panel Ac - Werner Finley/Rittal/Lextecnoid H. Stabilizer - Neel/Servomax /Consul/Farmax/Equivalent I. Lubrication- Cenlube/Dropco/Equivalent J. Coolant Pump - Rajamane/Grundfos K. Cutting Tools And Holders - Sandvik/Taegutec/ Kennametal /Seco/Iscar/Mitsub Ishi , 12) Cutting Tools & Tool Holders 1. External Turning Holder, Insert Type, Mwlnl - Holder 4Qty. (Insert Wnmg 40 Nos.) 2. External Turning Holder, Insert Type, Mvjnl - Holder 4Qty. (Insert Vnmg 20 Nos.) 3. External Turning Holder, Insert Type, Pdjnr - Holder 4Qty. (Insert Dnmg 20 Nos.) 4. Threading Holder - External, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 5. Threading Holder - Internal, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 6. Grooving Holder External, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 7. Grooving Holder Internal, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 8. Parting Off Holder For Insert Width 2 Mm, Lh - Holder 4Qty. (Insert 2Mm 30 Nos.) 9. Boring Holder Sclcl For Minimum Bore Dia. 12Mm - Holder 4Qty. (Insert Wcmt 60 Nos.) 10. Boring Holder Sclcl For Minimum Bore Dia. 16 Mm - Holder 4Qty. (Insert Ccmt 60 Nos.) 11. Internal Grooving Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert 2Mm 30 Nos.) 12. Internal Threading Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert W Mm 30 Nos.) 13. Insert Drill 12.7 Mm - Holder 4Qty. (Insert Suitable 30 Sets.) 14. Reducing Sleeves For Internal Holders - Dia 12 And 16 Mm - 2 Sets 15. Centre Drill Hss A 2.5 X 6.3 - 6 Qty. 16. Twist Drill Hss Straight Shank, Dia 6,8,10,12 Mm - 6 Sets 17. Collets Suitable For The Above Drills - 2 Sets 18. Collet Holder - 4 Nos. 19. Boring Bar Holder - 3 Nos C.N.C Lathe Machine With Accessories. 1. D- List Of Additional Machines, Tools And Equipment For Cnc Turn Center : D) Digimatic Electronic Vernier Caliper 200 Mm. - 2 Nos. E) Digimatic Electronic Outside Micro Meter (0 To 25 Mm & 25 To 50 Mm) Lc 0.001 Mm. - 1 Nos Each. , Desktop Computers Compatible To Run Simulation Software With Lan Facility. Dell / Lenovo / Hp Specification - Cpu - 64 Bit I7 Or Latest Processor Speed - 3Ghz Or Higher Ram 12 Gb Ddr - Iii Or Higher, Wi-Fi Enabled. Network Card - Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor (Min. 21 Inch.) Licensed Operating System And Antivirus Compatible With Trade Related Software. 01 Tb Hard Disk Nvidia Graphic Card , Ss And Sc Centre Lathe (All Geared) With Minimum Specification As: Centre Height 150 Mm And Centre Distance 750Mm Along With 4 Jaw Chuck, Self-Centering Chuck, Auto Feed System, Safety Guard, Motorized Coolant System And Lighting Arrangement, Set Of Lathe Tools, Lathe Carriers Make - Kirloskar /Hmt/ S Micrometric , Pillar Drill Machine (All Geared) 0-25Mm Drill Holding Capacity With Drill Chuck & Keys. Make - Ifco/ Skp / Energi , Cylindrical External Grinding Machine Fully Motorized With Dressing Arrangement And Supplied With Face Plates And Driving Dogs, 3 Jaw Self-Centering Chuck,4 Jaw Independent Chuck, Tail Stock Assorted Center Pump With Tank And Pipe Fittings Spanners And Grease Gun (Each Machine To Be Supplied With Assorted Grinding Machine For General Purpose Work With Internal Grinding Attachment) With Minimum Specification As: To Accommodate 750Mm Job With Center Height 150Mm. Wheel Diameter X Width=300X25Mm Make - Hmt-K 130 U / S-Micrometic / Hi Life , Radial Drilling Machine 32Mm Diameter With Std. Accessories. Drill Chuck & Plain Machine Vice 250 Mm Make - Hmt / Bfw / Batliboi , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Long With 3-Jaw, 4-Jaw Chuck Auto Feed System, Taper Turning Attachment, Coolant Pump, Safety Guard, And Machine Light Arrangement. Make - Kirloskar / Hmt / S Micrometric , Rockwell Hardness Testing Machine Digital Type With Standard Accessories / Digital Type Make - Mitutoyo/ Sagar/ Sinowon / Saroj / Sai Dro , Profile Projector (5 Micron) Re Solution 0.001Mm Projection Scream - Effective Diameter 300 Mm, Rotation Angle: +/- 360 Degree Angle Reading - 0.01 Degree Or 1 (Commutative) Projection Lens - 10 X Lens Group (Standard Arrangement) 20X50X100 X Is Set As On Option. Measuring Range - 200X200 Mm Quickly Move X, Y Axes, Power : 220 Vac Make - Mitutoyo / Nicon / Metzer , Co-Ordinate Measuring Machine (5 Micron) Measuring Range 500X700X500Mm Make - Nicon / Mitutoyo / Devine Technology , Fly Press (Any Model Minimum 12 Tons Capacity) Make - Taj Enterprises / Bharat Machinery And Spares / Orient Machine Tool , Power Press M/C (Hydraulic) Minimum 02 Tons Capacity Standard And Required Optional Accessories Make - Foreman / Amino / Omkar Enterprises , Auto Cad & Cam Latest Version - For Training Purpose Make - Autodesk , Solid Works / Any Latest - Latest Version - For Training Purpose Make - Dassasult System Solid Work Corporation , Smart Touch Screen Panel For Smart Class Room (65) Usb Connector, Led Interactive Pen, Mounting, Users Manual Electronics File Make - Samsung / Smart Guru / Vincon System , Multimedia Based Simulator For Cnc Technology & Interactive Cnc Part Programming Software For Turning & Milling With Virtual Machine. Operation & Simulation Using Popular Operation. Control System Such As Fanuc, Siemens, Etc. (Web-Based Or Licensed Based.) - For Training Purpose Make - Cad Mech / Indiasoft / Fanuc / Krb Electronic Solution , Cnc Vertical Machining Centre With Std. Accessories Make - Bfw / Moriseiki / Makino Specification , 1) Machine Capacity A)Table Size - 500X250 Or Higher Mm B) Max. Load On Table 150 Or Higher C)T Slot Dimension (N X W X P) Mm 3X14X100 Or Higher D)Table Height From Floor 800 ~ 900 Mm E) Cast Iron Grade For Bed And Saddle Grade 25 Or Equivalent F)Machine Net Weight 1500 Or Higher Kg , 2) Spindle A) Spindle Nose Bt30 B) Minimum Distance (Spindle Nose To Table)100 - 150 Mm D) Maximum Spindle Speed 6000 Or Higher Rpm E) Spindle Power, Continuous 3.7 Or Higher Kw F) Type Of Drive Ac Servo Spindle Motor (Digital) G) Spindle Bearing Class P4 H) Front Bearing Dia. (Id) 50 Or Higher Mm , 3) Axes A) X - Axis Travel 300 Or Higher Mm B) Y - Axis Travel 250 Or Higher Mm C) Z - Axis Travel 250 Or Higher Mm D) Rapid Traverse - X/Y/Z 20/20/20 Or Higher M/Min E) Minimum Programmable Command X/Y/ Z - 0.001 Mm F) Programmable Feed Range - X, Y & Z Axes 10 - 10000 Mm/Min G) Type Of Drive Ac Servo Motor H) Motor Torque - X & Y Axes 3 Or Higher Nm I) Motor Torque - Z Axis 6 Or Higher With Brake Nm J) Ball Screw - X,Y& Z Axes (Diameter X Pitch) 25 X 10 Or Higher Mm K) Ball Screw Finish - X, Y & Z Axes Ground And Hardened L) Ball Screw Class - X, Y & Z Axes Pre-Loaded With C3 Or Better M) Guide Ways - X, Y & Z Axes Antifriction Linear Motion Guide Way N) Guide Ways Size - X, Y & Z Axes 25 Or Higher Mm O) Guide Way Precision - X, Y, & Z Axes P Class , 4) Automatic Tool Changer A) Number Of Tool Pockets 8 Or Higher Nos B) Max Tool Diameter 80 Or Higher Mm C) Tool Selection Bi-Directional D) Tool Shank Type Bt30 E) Tool Weight Max 2.5 For Bt30 F) Tool Length Max 100 ~150 For Bt30 G) Tool Change Time (Chip To Chip) 5 Or Lower Sec H) Tool Clamp & Unclamp Disc Spring & Hydro-Pneumatic , 5) Accuracy As Per Iso 230-2 A) Positioning Accuracy For X,Y & Z Axes 0.012 Mm B) Repeatability For X,Y & Z Axes ±0.007 Mm C) Geometrical Alignment Iso 10791-Part 1 D) Accuracy Of Finish Test Piece Iso 10791-Part 7 , 6) Cnc System A) Control System - Fanuc B) Motors & Drives Compatible With Cnc Controllers As Mentioned Above C) System Resolution 0.001 Mm D) Tool Number Display On Machine Operator Panel E) Machine Control Panel Feed Rate, Spindle Speed Override Knob F) Mpg (Manual Pulse Generator) On Machine Operator Panel G) Cnc Features Graphic Simulation, Programming Help, Tool Offsets Mdi, Absolute/Incremental Positioning, Pitch Error Compensation , 7) Coolant/Lubrication A) Coolant Tank Capacity 100 Or Higher Litres B) Coolant Pump Motor 0.37 Kw C) Coolant Pump Output 20 Or Higher L Pm D) Lubrication Type Automatic Centralized Lubrication E) Lubrication Tank Capacity 3 Or Higher Liters , 8) Air Compressor For Tool Unclamp A) Compressor Type Screw Type With Dryer, Filter & Air Receiver B) Tank Capacity 200 Or Higher Liters C) Air Flow 10 Or Higher Cfm D) Pressure 7 Max. Bar , 9) Power Source A) Mains Supply (± 10 %) 415 V, 3 Ph., 50Hz B) Total Connected Load Requirement Approx. 15 Kva , 10) Standard Equipment A) Voltage Stabilizer 15 Kva B) Air Conditioning Unit For Electrical Cabinet As Required C) Backup Cd For Plc Ladder Logic 1 No. D) Machine Lightning 1 No. E) Levelling Pads And Jacking Screws 4 Nos. F) Operation Manual 1 No. G) Maintenance Manual 1 No. H) Installation Kit 1 No. I) Maintenance Tool Kit 1 No. J) 6 Rack Tool Trolley (Size 25X22X45) With Lock 1 No. H) Machine Guarding With Safety Compliance 1 No. , 11) Makes Of Critical Components A) Lm Guide Ways - Hiwin/Thk/Pmi/Star B) Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C) Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D) Atc - Pragati/Gifu E) Panel Ac - Werner Finley/Rittal/Lextecnoid F) Stabilizer - Neel/Se Rvomax/Consul/Farmax G) Lubrication - Cenlube/Dropco H) Coolant Pump - Rajamane/Gru Ndfos I) Cutting Tools And Holders - Sandvik/Taegutec/Ken Nametal/Seco/Mitsubishi J) Air Compressor (Capacity: 6 Kg/Cm2 - 300 Godrej/Elgi/Kaeser/Atlascopco L Pm Min.) , 12) Cutting Tools & Tool Holders (For Bt30 As Per Machine Supplied) A. Face Mill 45 Degree 63 Mm. Insert Type - 4 No. Suitable Inserts - 15 No. B. Face Mill Square Shoulder 50 Mm. Insert Type - 4No. Suitable Inserts - 15 No. C. Twist Drill Hss Straight Shank 6, 6.7, 8.5, 9.7 - 4 No. D. Spot Drill Carbide, Dia. 8 Mm X 90° - 4 No. Suitable Inserts - 60 No. E. Drill Insert Type - 16 Mm - 4 No. Suitable Inserts - 30 No. F. Solid Carbide Twist Drill Straight Shank - 8 Mm - 4 No. G. Solid Carbide End Mill Straight Shank - 10, 12 Mm Dia. - 4 No. H. End Mill Insert Type Straight Shank - 16 Mm Dia. - 4 No. Suitable Inserts - 30 No. I. Machine Taps Hss - M8, M10 - 4 No. J. Solid Carbide Reamer Straight Shank - 10 Mm - 4 No. K. Finish Boring Bar Dia. 20 To 25 Mm- 3 No. Suitable Inserts - 30 No L. Holder For Face Mills (Adapter) - 4 No. Suitable Incert - 60 Nos. M. Collets For Above Drills, Reamers, End Mills - 02 Sets N. Collet Holder Suitable For Collets - 4 No. O. Side Lock Holder For 16 Mm Insert Drill - 2 No. P. Machine Vice 0-150 Mm Range - Mechanical Type - 1 No. Q. C Spanner For Tightening Tools In Holder - 2 No. R. Magnetic Dial Stand - 2 No. S. Mallet - 02 No. T. Tap Wrench - 2 No. U. Hands Tools Set ( Spanners, Allen Keys, Etc.,) - 1 Box V. T Nuts, Strap Clamps, Clamping Nuts And Studs - 2 Set , Three / Four Door Refrigerator (Inverter Type) Specification - 300 Liter With Hc-600 A Gas. (1 Each) Make - Godrej / Whirlpool / Lg , Core Drill Machine Specification - Up To 2 To 2.5 Hammer Chiseling Bit 1500 Watt Make - Crompton / Power Hours / Bosch , Duct Able Split A/C Reciprocating Compressor Specification - Cap 1.5 Ton With R-22 Evapora(4 Copper) Make - Blue Star / Voltas / Daikin , Recovery Unit With Cylinders Specification - Cfc-Hfc,Hcfc, - 1 Each Cylinders Make - Trust Hal / Robin Air Rg-3 / Rishabh Enterprises , Decibel Meter 03 To 100 Db Make - Cadrim / Bosch / Generc , Descaling Pump Set With Stainless Steel Impeller And Accessories (1/2 Hp) Make - Bosch / Crompton / Robin Air , Fan Coil Unit With Water Valves Specification - 2 Way & 3 Way Valves (02 Ton) Make - Nutech Zeco / Blue Star / Voltas , Circulating Water Pump 0.5 Hp With Stainless Steel, Tank Capacity Inlet/Outlet Provision Make - Sharp / Lubi / Crompton , Water Cooler Storage Type Hfc-134A Specification - 200 Litter Reciprocating Compressor. Make - Blue Star /Voltas / Usha , Package A/C Air Cooled Type With Open Type Reciprocating Compressor Fins Type Condenser (05 Ton) Make - Blue Star / Voltas / Daikin , Bus A/C Tutorial Model Make - Estern Air / Tata Motors / Cool Ways. Ltd , Automatic Ice Coober Machine Specification - 5 Kg/Hr., Ice Cube - Material Stainless Steel Make - Godrej / Voltas / Blue Star , Walk In Cooler Puf Insulated Cold Room Specification - 01 Ton, 6X5X8 Foot, Cold Room Temp - 0 To 5° C Degree. Air Cooled Evaporator & Condenser Copper Tubing. Make - Unicool / Blue Star / Voltas , Shell Tube Type Dx Chiller Specification - 5 Ton Material - Copper Tubing Only Make - Voltas / Blue Star / Carrier
Contract Date: Ref. Documents Contract Value : Ref. Document
Trust & NGO No of Bidders 3
Maharashtra View Result →
32.
Defence #10832999 Price Bid
Tender For Additional / Alternator To Swimming Pool And Other Works Under Age B/R Iii At Chandimandir; 1 Dubbing out average 20mm thick on irregular faces of walls, exposed reinforced surfaces, in Cement and Sand mortar 1:4,including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified. 2 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 3 providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed 4 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 5 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base finished fair and rough without using extra cement, complete all as specified and directed. 6 Coloured non skid porcelain tiles exterior grade 300x300x 8-10mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed 7 Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. 8 Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, including 15mm thick in cement mortar 1:6, complete all as specified and directed 9 Coloured vitrified ceramic tiles, 10mm thick (square/rectangular ) , area of each tiles exc 0.18 Sqm but n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 10 20mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in, set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compelte all as specified and directed. 11 Kota Stone Slab flooring, 18-20mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. 12 Factory made machine pressed, pre polished, coloured chequered cement concrete tiles 250mm x 250mm x 20-22mm thick (with grey cement and no pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 13 Plain cement mortar 1:3:6 (type C-2 using 20mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,all as specified.Note: 10mm construction joint will be provided and panel should not be more than 3metre in length and joint filled with filler bitumen and sand in ratio (1:3) 14 Two coats of oil bound distemper on wall surfaces over a coat of primer including preparation of new plastered surfaces complete all as specified and directed 15 Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. 16 Applying Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paintof required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. 17 Prepartion of new surface and applying two coat of premium acrylic emulsion weather proof exterior paint over a coat of primer complete all as specified and directed. 18 Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, inclunding using water proofing compound complete all as specified.Note : WPC shall be measured and paid separately. 19 Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. 20 Rendering 15mm thickin Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. 21 PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement, complete all as specified and directed. 22 15mm thick (average thickness) rendering on roof surfaces inclduing flashings and junction of parapets etc finished even and fair in cement mortar 1:4 using water proofing compound as per manufacturers instruction after brushing cement slurry complete all as specified and directed 23 Supply only integral water proofing compound complete all as specified & directed. 24 3mm thick Atactic polypropylene polymer (APP) modified prefabricated water proofing membrane, based polymeric membrane minimum weighing 3kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished, complete all as specified & directed. 25 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete allas specified and directed. 26 Factory made steel window box type with side hung shutters including box type hinges and oneshop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete with glazing bars, dovetailed or welded fixed with and including MS flat of suitable size for fixing grills and guards bars etc , complete all as specified. 27 Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square, area not exc 0.5 sq. mtr in each pane,complete all as specified and directed. 28 Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,including filling of PCC 1:3:6 in hollow frame complete all as specified and directed. 29 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated, all as specified and directed. 30 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). 31 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge 32 Butt hinges 100mm size, of extruded aluminum alloy with galvanisedmild steel hinge pin, anodised, type C-21, complete all as specified and directed. 33 200 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 34 150 mm extruded aluminium handles cast typecomplete all as specified and directed. 35 Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. 36 Factorymade fixed type steel ventilator with glazing bar compelte all as specified and directed. 37 Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples, complete all as specified and directed. 38 preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 39 Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. 40 Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. 41 Two coats of synthetic enamel paint over priming coat onnew stone and concrete surfaces of any description not otherwise described over 10 cm width or girth including preparation of new surfaces complete all as specified 42 Hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and directed(Note : Colour/design and pattern shall be as decided by the GE) 43 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws, complete all as specified and directed 44 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws,fixed as in repair complete all as specified and directed 45 Rolled sections as in main and cross beams, hip and jack rafters,purlins where connectedto common rafters and running rails and guidesforsliding doors, fixedwithangle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed. 46 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O all as specified and directed. 47 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O including dismantling old iron all as specified and directed. 48 Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge 49 Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed. 50 TMT bars for reinforcement, 6 to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. 51 Pre-painted galvalume aluminium zinc (AZ-70) coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc , complete all as specified & directed by Engineer-in-charge. 52 Powder coated aluminium(minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, including making good dismantled portion with PCC (1:2:4) type B-1 in CM 1:3 complete all as specified and directed. 53 5.00mm thick ordinary quality tinted glass,fixed to aluminum frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. 54 Door closer hydraulically regulated aluminum (die cast) body, designation No 2, universal type, suitable for door shutters of 701mm to 850mmin width and of weight between 36 to 60 Kg,complete all as specified and directed. 55 Demolition of cement concrete (unreinforced) any description and in any position complete all as specified. 56 Demolition of stone slabs and tiles of any description or thicknessin floors laid, bedded and pointed in any mortar complete all as specified and directed. 57 Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed 58 Hard core ofbroken stone or boulders of gauge of guage n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 59 Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as speciied and directed. 60 Cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). 61 Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified. 62 Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. 63 Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. 64 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in beams, cantilevers , bressumers,lintels over 1.5m span, all as specified and directed . (reinforcement shall be measured and paid for separately). 65 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately). 66 Material and labour form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 67 Form work to chullah hoods, chajjas and similar items including edges / sides and soffits of lintelsetc rough finished surface of concrete flat complete all as specified and directed. 68 Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified. 69 Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed 70 Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed. 71 12mm thick toughned glassas in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holeswith necessary screws/ beading, rubber packing, L patch bottom and top, self closing patch etc,complete all as specified and directed.NOTE : Decoratiion/Design or unit name, emblem, crest over glass shutter will be approved by Engr-in-Charge before executionand the rates are inclusive of the same 72 Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. 73 300 mm long stainless steel handle, fancy type , fixed to toughened glass, complete all as specified and directed. 74 Stainless steel lock for 10-12mm thick glass door, having knob inside with three keys, satin finish, complete all as specified and directed. 75 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. 76 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. 77 All as per serial item 76 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed 78 All as per serial item 76 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 79 All as per serial item 76 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area) cable as earth continuity conductor 80 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 81 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 82 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 83 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 84 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 85 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 86 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 87 LED lamp9 watts, B-22 type complete all as specified . 88 Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCBs ,MCBs etcand removing from site, Complete all as specified and directed . 89 MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 90 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . 91 TPN distribution board double door flush mounting with provisions for MCB TPN 6 way, 415 volts having IP 43 protection Complete all as specified and directed . 92 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 93 MCB, DP, 240 volt,32Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 94 MCB, SP, 240 volt,40 to 63Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 95 MCB SP , 240 volt, 6Amps to 32Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 96 MCB , TPN/FP 40 to 100 Amp 415 volts, 16 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 97 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP 20 Amp MCB complete all as speicified and directed. 98 Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose tofan complete all as specified and directed. 99 LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed. 100 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completecomplete all as specified and directed. 101 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. 102 LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. 103 Exhaust fan energy efficient metallic blades heavy duty turbo force of size 300mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washerscomplete all as specified and directed. 104 Wall mounted fan PVC body, 400mm sweep, 230 volt , AC,quick start torque motor with copper winding complete all as specified and directed. 105 LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ncluding taking down any type ceiling fittingcomplee all as specified and directed. 106 LED flood light fitting 100 Watt 6500K outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrision resistantincluding thermal management in multiple optics complete with IP 65 protectioncomplete all as specified and directed. 107 Suface mounting back lit LED 1 x 4 tile in CRCA housing with full opel diffuser for soft & glare free distribution panel with surge protection complete including cutting hole of required size in POP/false ceiling making good disturbedincluding taking down any type ceiling fittingcomplee all as specified and directed. 108 Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 109 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE: (i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 110 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. 111 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), completeall as specified and directed. 112 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. 113 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection,complete all as specified and directed. 114 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 3.5core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 115 32mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
33.
Public Administrative Department #10809106 Price Bid
Tender For Electric Work In Municipal Area Sultanpur- 1 Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR Poles with Octagonal Cross Section 9 Mtr. 2 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Single arm overhang 3 Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 4 LED Street Light fixture with Minimum lumen output 3700 lm 5 LED Street Light fixture with Minimum lumen output 5600 lm 6 LED Street Light fixture with Minimum lumen output 8700 lm 7 LED Street Light fixture with Minimum lumen output 15000 lm 8 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . High Power LED Flood Light Minimum lumen output 25000 lm 9 Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discoms standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 75mm x 90mm 10 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 11 Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discoms specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR LT cross arm 600 mm long with clamp 12 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq.mm 13 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 14 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 A to 32 A rating 15 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 50/63 A rating 16 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 80 Amp 17 SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSRup to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 18 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approve One day & week reserve (digital type )d by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 19 Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 8.0 Mtr long PCC pole of 200 Kg Working Load 20 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discoms standard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 21 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3 X 25 sq. mm. + 1X25 sq. mm. (insulated) 22 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 2 core 23 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4 core 24 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 3.5core 25 P & F of IP 55 protected light controlled switch based oninfrared sensing and daylight with built in over loadprotection, timer to switch OFF at preselected time.Switch shall have 7 day power backup withouthampering of preset time and over ride facility formaintenance purpose Suitable for 15 kw load (three phase) includingcontactor, MCB, cable glands, terminal block andlocking arrangement 26 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 mm Dia. 27 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 28 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 SWG G.I. ( Hot Dipped ) Wire 29 Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 30 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. 31 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR B class 50mm dia 33 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer Cement Concrete Grade M-15 and above and PCC blocks 34 Providing & Fixing of ISO certified company made bolted type/ Din type HBC (High breaking capacity) fuse links of 80 KA breaking capacity,as per PWD specification for electrical Works conforming to IS:13703 in the existing fuse base, fuse switch unit etc. of the following type and rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 63 A to 160 A Size 00 35 Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 6.0 sq.mm 36 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or teeconnections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 37 LINE MAN/WIRE MAN Annual Rate Contract of regular opration and maintence and Changing faulty spare parts, sheets, Wire and Door Switch of all existing pannel complete for 12 month (30 PENNEL) 38 Annual Rate Contract of regular opration and maintence of all type LED street lights fixure with all wattage (20,40,70,130,200)/ HIGH MAST with Complate materials, Drivers, Glass, Chip, Wire, etc Complate Including Line Maintence For 12 Month Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
34.
Housing Urban and Rular Development #10803700 Price Bid
E-Quotation No.5 For 2022-23 E Rate Quotation For Preparation Of Ssr For Various Item Which Is Mention In Notice , For Steel Structure / Tmt -Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) For Concrete Surface -Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kleox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Top Terrace Waterproofing -- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Waterproofing Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Waterproofing Of Concrete Surfaces Of Terrace To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Of Existing Terrace Surface Upto Mother Slab Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60Of Dimple Chemicals & Services Pvt. Ltd After Finishing, After Top Coat Application, Pcc Will Be Done Up To 50 Mmthickness ( Or As Per Site Condition ) Of Desire Slope To Drain The Water And Kept Ponded For Continuous Period Of 3 Days To Detect Any Seepage / Leakage / Dampness If Any, The Surface Then Shall Be Cleared, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd After Finishing It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas, Lift Jointsetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Road Surfaces To A Thickness Upto 15 Mm Or As Per Surface Conditions And Also Treatment Of Pot Holes, Cracksetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 25 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying Poly Ironite Ceramic Cementitious ( Picc ) Ofdimple Chemicals & Services Pvt. Ltd Ensure Self Curing, High Abrasion Resistant, Non-Shrink, High Compressive Strength, Low Porosity, Uv Resistant Coating Mortar On Existing Well Gsb Of 100 Mm Thickness, Get Compacted Andlevelled , Cure The Surfacethen Applyingself Curing Coating Picc Mortarin Properation Of 1;1 ( Nicomix Series : Metal ) For 50 Mm Thickness After Stamp The Surface By Special Concrete Stamping Mould As Per Specified Texture And Colour Etc. Next Day Apply Finish Coat Of Kelmer A60 Of Dimple Chemical & Services Pvt. Ltd Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. ( Note- Gsb , Colour & Stamping Rates Not Included In This Ra ) , Masonry Bridge Repair Work:- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For T-Pointing To A Depthupto 50 Mm Or As Per Surface Conditions And Raised On Stone Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Joints With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Top Coat Will Be Done With Kelmer A 60 + Niccoat Pc On Picc To Seal The Surface And Reduce The Porosity Etc Complete As Per Specification Including Cost Of All Material, Machinery, Labour, Scaffolding, Transportation Etc. With All Leads And Lifts As Directed By The Engineer-In-Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm In A Ratio Of 1:1 ( Picc Mortar1 Part: Metal 6Mm 1Part ) Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 In To Above Morter For Normal Setting Of Dimple Chemicals & Services Pvt. Ltd. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 Of Dimple Chemicals & Services Pvt. Ltd. On Above Mortar Picc Will Be Ready To Traffic Load After 1 Hr Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying 30 Mm Thick Self Curing Ceramic Polymer Microconcrete Of Dimple Chemicals & Services Pvt. Ltd. Having Compressive Strength Above M30, Non Shrink, Impermeable, Filling Mortar In Cavities Like Beams, Column Etc. To Load Carrying R.C.C Member In One Or Two Layers ( Depending Upon The Site Condition ) On Cleaned Concrete Surface , Includinghoney Comb Area ( Using Manual / Mechanical Means ) . Mixingmortar Of Nicocil C80 And Fresh 53 Grade Cement With Required Water Cement Ratio For Desired Consistency And Applying And Finishing By Manual Trowelling , Curing After Curing Initial Setting Time Etc, As Per Manufacturers Specification Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Kelox R 101 ( Resin ) + Kelox H 404 ( Hardener ) A Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. For Bonding Old Concrete To New Picc Mortar, After Mixing Slowly In Predefined Ratio And Applying By Brush On The Surface. When It Is Tacky Then Apply The Picc Mortar Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System Of Dimple Chemicals & Services Pvt. Ltd., This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. After 2 To 3 Hrs Of Wrapping Apply Final Coat Of Duraguard When Surface Is Tacky. This Coats Will Give The Thickness Approx. 350 Micron, As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System, Kelox Rb5050 & Kelox Rh4040 This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As Abrasion & Impact Resistance Followed By Top Coat With Bituminous Epoxy. This Coating Gives Better Performance As Compare To Coatings Specified In Is 10221 . Apply 2 Coats With A Thickness 1Mm ( Bituminous Epoxy + Duramesh+ Bituminous Epoxy ) As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) After Primer Application Final Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System Kelox Rb 5050 Kelox Rh 4040, This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Apply 2 Coats With A Thickness Of 300 Micron On Prepared Metal Surface Etc. It Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance, Corrosion Protection Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface . Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. Also Reduces Frictional Resistance To Flow Of Water. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Water Proofing Of Swimming Pool -- Providing And Applying Impermeable, Monolithic Application, Uv Resistant, Self Curing, Non Toxic, High Compressive Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Which Consists Of Nicomix Series + 53 Grade Cement + Water Of Dimple Chemicals & Services Pvt. Ltd.For Resurfacing The Concrete Surfaces Of Swimming Pool To A Thickness Upto 10 Mm Or As Per Surface Condition And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. By Removing Loose Material, Dust Particles, Grout Slurry By Breaking It With Manual / Mechanical Means. Removing Of Existing Embedded M.S. Bar If Any, Cleaning The Lift Joints, Honey Combing Areas And Entire Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removal Of Algae - Fungi Followed With High Pressure Water Jet. Apply Bond Coat Named As Kelox R 101 + Kelox H 404Which Is Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. Before Picc Application For Suitable Bond Between Old Surface To New Picc Mortar And Then Do The Picc Application Providing With Top Coat Of Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd. After Finishing, Complete As Per Specification Including Materials, Machinery, Labour , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Durabond Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique Blend Of Organic And Inorganic Materials Consisting Ceramic Ironite, Active Ceramic, Cement And Water Miscible Modified Epoxy. As This Contain Water Miscible Epoxy, Can Be Applied On Wet Surface With Better Bond Strength Between Old Concrete And Waterproofing Coating Material For External Surface Of Building. Crack Filling Will Be Done By Duraguardof Dimple Chemicals & Services Pvt. Ltd, Having Cold Weldling Properties Which Cn Stick Anything To Anything. Surface Cleaning Is Done To Remove Loose Material, Dust Particles By Breaking Using Manual And / Or Mechanical Means, Cleaning The Cracks, Small Potholes And Surface Preparation Will Be Done With Special Chemical Name Steripure 10Of Dimple Chemicals & Services Pvt. Ltd For Algae- Fungi Removal And Then Clean It With High Pressure Water Jet, Then Applying A Durabond Of 2 Coats A Special Type Of Coat Suitable To Bond Old To New Concrete Finishing, Complete As Per Specification Including Materials, Machinery, Labour, Scaffolding , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Duraclean Od Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Emulsification & Dispersion Of Oil And Grease Spilled On Any Surface ( Concrete, Metal Or Water ) .Apply By Brush Or Spray On The Surface To Be Cleaned, Wait For About 5 – 10 Minutes, Wash The Surface With High Water Presure Jet.Repeat Process For Heavy Spillage And Surfaces Soaked In Oil Till It Is De-Oiled. Wait For 24 Hrs And See Whether The Penetrated Oil Comes Out To The Outer Surface, If Yes Then Repeat The Step 2-4. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Water Proofing Of Water Tank -- Providing And Applying Impermeable, Uv Resistant, Self Curing, Non Toxic, High Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces Of Water Tank To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. Is To Be Done With Picc By Removing Loose Material, Dust Particles, By Breaking Using Manual And / Or Mechanical Means, Removing Of Existing Embedded M.S. Bar If Any, Cleaning Of Lift Joints, Honey Combing Areas And Surface Is To Be Done Using Special Chemical Named Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Algae- Fungi Removal Followed By Compressed Water Jet. Apply Primer Coat Name Kelox R 101 + Kelox H 404 A Water Miscible Epoxy Of Dimple Chemicals And Services Pvt. Ltd. Before Picc Application. Kelox Is A Bonding Agent Between Old To New Concrete Mortar. Top Coat Will Be Done With Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd., Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Impermeable, Anti-Wear Coating On Concrete & Bitumen Road :- Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. Having High Abrasion Resistant, Anti-Skid, Impermeable, Non Shrink, High Compressive Strength, For Concrete And Bitumen Road Coating Etc. Including Cleaning Of Concrete / Bitumen Road Surface By Wire Brush, Water Jet, Air Blower Etc. ( Using Other Mechanical / Manual Means ) To Remove Existing Loose Particles, Dirt Etc. Then Do Bituminous Coating By Taking Kelox Rb 5050 Of Dimple Chemicals & Services Pvt. Ltd.In A Clean Container & Add Kelox Rh 4040 Of Dimple Chemicals & Services Pvt. Ltd.In It, Apply This Mixture By Wiper On The Cleaned Surface.Top Coat Is Done Using Ready To Use Product I.E. Nicomix Butacoat Of Dimple Chemicals & Services Pvt. Ltd. , After Bituminous Epoxy Coating Immediately Sprinkle Nicomix Butacoat On Bituminous Epoxy Coating To Provide Impermeable, Antiwear & Antiskid Surface. After 10-15 Min, Use Roller On Top Coat I.E. On Nicomix Butacoatfor Compaction. After 6 Hours, Coated Surface Is Ready To Take The Load Of Traffic Movement, Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. An Impermeable, Excellent Bonding With Old Surface, Non Shrink Repair Coating For Concrete Terrace & Etp Plants Includs & Steel Structurebituminous Coating By Taking Kelox Rb 5050 In A Clean Container & Add Kelox Rh 4040 In It, Stirr Well To Get Homogeneous Mixture, Apply This Mixture By Brush Type Wiper On The Cleaned Surface I, E Dust And Loose Partical Free, No Algae Fungi, Non Oily Surface, Corrosion Free Etc. Bituminious Epoxy Coating Is A Two Pack System Consist Of Kelox Rb 5050 Is A Blend Of Bitumen Emulsion With Epoxy Resin And Kelox H 404 Is A Modified Hardener.It Ensures Strong Adhesion With Any Substrate Like Concrete Road, Bituminous Road, Metal, Wood Etc. Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing& Applyinghigh Abrasive Resistant, Impermeable , High Strength, Non Shrink, Self Curing Poly Ironite Ceramic Cementatious ( Picc ) Of Dimple Chemical Services And Pvt Ltd, Which Consists Of Nicomix Series + 53 Grade Cement + Water I, E Piccmortar Mixing With Water Misible Epoxy I.E Kellox R 101 + Kelox H 404 Of Dimple Chemical Services And Pvt Ltdin The Ratio Of 80:20 ( Picc:Epoxy ) And Fill Thecracksfor 10 Mm Width & 10 Mm Depth With 1 Rmt Lengthon The Concrete Surface Ofroad, Industrial Floor Etc, Including Cleaning Of Cracks ( Using Manual / Mechanical Means ) , Power Tool Cleaning, Clean With Special Chemical Steripure 10 Of Dimple Chemical Services And Pvt Ltd For Alge Fungi Removal & Duraclean Od Of Dimple Chemical Services And Pvt Ltd For Oil Removalwith High Pressure Water Jet, Apply Bond Coat Of Water Misible Epoxy Of Keloxbefore Picc:Epoxy Application And Finishing, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts And Any Other Incidental Charges As Directed By The Engineer In Charge. ( As Per Data Rate ) , Providing And Applying Duraclean Wr Of Dimple Chemicals & Services Pvt. Ltd. An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By Washing Or Mopping. Mesure Burr On The Surface, Spray Duraclean Wr On Surface To Be Cleaned, Wait For 5-10 Min And Then Wash It Off With High Pressure Water Jet. Again Mesure Burr On The Surface, Repeat The Process Till Burr Is Below 25 Micron Or 10% Of The Orignal Burr. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Clonon Of Dimple Chemicals & Services Pvt. Ltd. Clonon Is A Revolutionary Product Forbroad Spectrum Odour Remover.Clonon Contains A Proprietary Combination With Major Ingredilents Like Active Lodophor Solution, Benzalkonium Chloride Glutaraldhyde And Others, Clonon Product Main Features Of Odour Remover, No Added Fragrance , Debonds Nano Particles From Surface, Bacteria Killer, Quik Action, Non Toxic Chemicals, Ready To Use, No Stain And Residue , Does Not Contain Formaldehyde, Biodegradable Environmental Friendly.Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Laying In Situ Cement Concrete M -30 With Tremix Treatment For 200 Mm Thickness For Concrete Road With Uniform Sprinklingthe Nicocil R 90 Of Dimple Chemicals & Services Pvt. Ltd Using Travelfor Surface Hardening , High Abrasion Resistance And Low Porosity.Also Is Includinglaying Plastic Sheet For 125 Micron Thickness With Groove Cutting Of 4 Mm Wide And 20 Mm Deep With Necessary Refilling With Polysulphidesealant ( Pouring Grade ) Confirming To Bs : 5212 - 1989 Into Sawed Groove Widened At Top For Sealant Reservoir Of Specified Size And Shape As Per Detailed Drawing Including Fixing Polyethylene Foam Backer Rod Of Required Diameter ( Excluding Reinforcement ) With Coarsen And Fine Aggregate Using V.S.I.Qualityartificial Sand Etc. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges As Directed By The Engineer In Charge. ( Note- Construction Of Concrete Road As Per Instruction Of Engineer-In-Charge Or Requirement, Rate Of Construction Not Included ) , Providing And Applying Steripure S 30 Of Dimple Chemicals & Services Pvt. Ltd. Is Antibacterial, Antifungal Water Base Solution To Remove Algae-Fungi From Concrete , Masonry , Metal, Stone, Tile , Wood, Paver Block And All Composite Material Surface. Spray Steripure S 30 ( Prepar Dillusion In 1 Part Steripuri S30 : 9 Part Water ) On Surface To Be Cleaned, Wait For 15 - 20 Mins Then Wash The Surface With High Pressure Water Jet. This Unique Product Kills The Roots Of Algae-Fungi Which Can Be Removed From Surface By High Pressure Water Jet Cleaning. Re-Growth Of Algae-Fungi Is Stopped Due To Removal Of Roots. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge. , Providing And Laying Of Rumble Strip Usingplastirib 2K 2 Component Cold Plastic Road Marking Material In Single Monolithic Application To Create Rumble Strip Raised Section 15 Mm - 20 Mm High , 200 To 300 Mm Wide And Spaced About 1 Meter Centre To Centre Of Roughly 6 Numbers At One Location, Across The Entire Carriageway. Each Rumble Marking Shall Be Made Complete With Drop On Solid Plus Reflective Glass Beads @ 350 Gm / Sqm Spread Throughout The Surface Of Marking. The Finished Surface Shall Be Levelled, Uniform , Free From Straks And Holes Including Surface Cleaning And Cost Of All Materials Etc. Complete. As Per Irc 99, These Rumble Strips Shall Be Applied As Traffic Calming Measure. , Kerb Stone / Vertical Surface Painting With Reflective Paint, Make Grade 1 ( As Per Is 164 ) Water Based Acrylic Paint, Preferably Mechnical Application For One Coat Priming Coat And 1 Uniform Retro Reflective Finish Coat In Required Colour. Yellow Retroreflecive Coat Shall Be Bright Yellow During Night With Minimum Rl ( Dry ) > 375 Mcd / M2 / Lux White Retroreflective Coat Shall Be Bright White During Night With Minium Rl ( Dry ) > 450 Mcd / M2 / Lux .Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Providing And Applying 2 Component Cold Plastic Night Glow Paint Rolled On Surfacing Material Solvent Free, High Build Two Pack Seamless, Tough, Skid Resistant, Material Which Has Property Of Attaining 600 Microns Thickness In Single Coat Application White ( Or As Required Colour ) Based On Glass And Colour Retaining Acralic Cross Linking Resin System For Coloured Road Surfacing Including Surface Cleaning And Cost Of All Material Etc. Complete. ( All Inclusive On Bitumen Or Concrete Surface ) Night Glow Paint Shall Preferably Be Roller Applied. After Glow Finish Surface Shall Provide Minimum Of 8 Hrs Glow After Fully Absorbing Ambient Light ( Visibile Light Or Uv Light ) For 15 - 30 Min. Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On - Bituminous Surface Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On- Concrete Surface With Application Of Special 2 Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Supplying And Fixing Of High Performance Moulded Shank Raised Pavement Marker / Cats Eye Made Of Reinforced Polycarbonate And Weather Protected Ip > 68 Abs Moulded Body Having 2 Compartment Scratch And Abrasion-Proof Prismatic Polycarbonate Lens Capable Of Providing A Total Internal Reflection Of The Light Entering The Lens Face And Shall Support A Load Per Wheel ( Per Axle ) Of 20000 Kg And Per Axle 40000 Kg Tested In Accordance To Astm 4280D & En 1463-1 And En 1463-2 And Morth. The Dimensions Of The Pavement Marker Being 100 X 100 X 18 Mm And Weight 140Gm, Pin 55 Mm Depth Dia 13 Mm In Star Shape For Better Gripfixing Will Be By Drilling Holes On The Road For The Shank To Go Inside, Without Nails And Using Cold Plastic-Based Adhesive As Per Manufacturers Recommendation And Complete As Directed By The Engineer. The Contractor And Manufacturer Shall Submit A Minimum 1 Yr Installation Warranty And 2 Years Reflectivity Warranty For Satisfactory Field Performance. , Supplying And Fixing Of Solar Road Studs ( High Performance ) Polycarbonate Body, Pavement Surface Mounted Compliant Withen1463 Part 3 Havinguni-Direction Or Bi-Directional With Solar Powered Led Illumination And Reflective Panel Having 1 ) Dimensions 115 X 100 X 8.5 Mm 2 ) Marker Shall Support A Load Of 20 Ton Tested In Accordance To En 1463 . 3 ) Waterproof And Dust Protection Ip > 68 4 ) Weight 117 Gram 5 ) Fixing Using 2 Coponent Cold Plastic Based Adhesive / Butyl Tape Or As Reccomended By Manufacturer 6 ) Working Temperature: Up To 80 Deg. C 7 ) The Contractor And Manufacturer Shall Submit A Technical Warraty Of 1 Yr. , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture And With Approved Stencil Pattern Following By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture Without Any Pattern ( Plain ) And Followed By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing And Fixing 50 Mm Thick Door Shutter Using 25 Block Board 10 Mm Ply On Either Side Of Block Board , 4 Mm Thick Veneer On One Side With Melamine Polish And 1 Mm Thick Laminate On Other Side , Ss Hinges ( Brass ) 125 Mm , Tower Bolt 380 Mm , Mortise Lock , Concealed Door Closer Including Necessary Teak Wood Bedding , Fevical , Screw & Labour For Fixing Etc Complete As Directed By Engineer In Charge , Providing And Fixing 50 Mm Thick Main Entrance Door Partly Panelled And Partly Glazed Door Using 25 Mm Block Board , 10 Mm Ply Garjan On Either Side , Teak Wood Beading Covered With On Side 4 Mm Thick Rich Veneer With Melamine Polish, Floor Spring , Concealed Lock , 1.2 M Handle Pair Of 25 Mm Dia , Glass Pannels Of 0.40 X 0.40 Including Necessary Fevicol , Nails Screw And Labour For Fixing Etc Complete , Providing And Fixing High Quality Inter Locking Concrete Cobble Stone Finish Pavers In Circular Form Having Area Of 1.218 Sqm ( Approximately 71 Or 74 Nos. In One Circle ) , Made By Using Rubber Moulds Of 60 Mm Thickness, Tested And Certified By Csir-Cbri Of Having Strength Of 500 Kg / Sqm. Pavers Should Have 10 Mm Face Layer In White Cement With Pigment Of Lanxess Or Tata Make And Base Mix In M40 Grade Concrete. The Pavers Should Be Made Available In Various Sizes To Make A Circle Of Approved Finish And Design Of Standard Make On A Bed Of Crushed Sand Of 25 To 30 Mm Thick Including Skirting Joints And Cleaning As Directed By Engineer Incharge Etc. Complete. Prior Approval Of Superintending Engineer Will Be Necessary . , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size600 Mm X 450 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Glass Bricks Of Size 190 Mm X 190 Mm X 80 Mm Fitted Inside Already Prepared Ss / Ms Fabrication Using Silicon Glass Sealant Before Placing Of Bricks And After Placing Of Bricks To Create A Bond Between Fabrication Material And Glass Bricks, Finishing The Surface By Filling The Gap Between Glass Bricks With White Cement Etc. Including Loading And Unloading Of The Material As Directed By Engineer In Charge. , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.65M*0.35 ) . , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.25M*0.35 ) . , Providing & Fixing Ester Resin Material 5Th Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflective Sheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 1St Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflectivesheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 200 Mtr Structure As Per Irc-26-1967 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessoriesfor Fixing Structure Excavation Of 0.60 X 0.60 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Milling Of Bituminous Pavement Upto Depth Of 50 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead Charges Of 10 Km As Directed By Engineer In Charge , Milling Of Bituminous Pavement Upto Depth Of 100 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Dismantling Of Rigid Concrete Pavement Upto Depth Of 50 Mm Using Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Re-Texturing Of Rigid Concrete Pavement Upto Depth Of 20 Mm Using Cold Milling Machine With Fine Milling Drum Of Width 1.5M Or Above Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Providing And Fixing Stainless Steel ( Grade 304 ) Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainlesssteel Nuts And Bolts Complete, I / C Fixing The Railling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixingh Accessories Such As Nuts, Bolts, Fasteners Etc. ) . , Providing Concrete Surfacing System With Deck Crs With Base Coat, Application Of Pattern In Stencil Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing Concrete Surfacing System With Deck Crs With Base Coat Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixingchevron Sign Boards In Rectangular Size Of 500X600 Mm Made Out Of ___Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 3.45 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 500X600mmmade Out Of 3Mm Aluminium Composite Material With 0.25Mm Skin Thickness On Either Side , Providing And Fixing One Way Hazard Marker Sign Boards In Rectangular Size Of 300X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 300X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing Two Way Hazard Marker Sign Boards In Rectangular Size Of 450X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge.450X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Encasement Of Columns And Beams By Placing 75 To 100 Mm Thick Free Flow High Strength Micro Concrete With Leak Proof Shuttering With All Equipments, Manpower Etc Complete , Providing And Applying Epoxy Mortar Epibond 11 In Areas Of Fixing Cracks, Charges For Repairing Of Full Depth Crack ( 30Mm Depth X 50Mm Width / Per Rmt ) On Pqc Pavement Using Cross Stitching Method As Per Specification Of Irc Sp : 83-2008. Making Chase Along Crack And Cleaning The Holes / Chase With Oil Free Compressed Air, Fixing Of Reinforcement In Holes Filled With Epoxy Resin In Enough Quantity For The Bar To Be Completely Coated When Inserted In The Hole, Chase Filling With Epoxy Epibond 11 ( 1:1:8 ) Resin+Hardner+Fine Sand As Per Manufacture Specification, Curing, Transportation, Required Machinery, Tool And Tackles Etc.Complete As Per Direction Of Eic. , Providing And Applying Volatile Corrosion Inhibiting Wax Powrthrow Ht Wax On Ht Lrpc Strands Before Embedment In Tendons, Lrpc Strands Of 12.7Mm & 15.2Mm , Tendon Duct Need To Be Lime Washed Prior To Insertion Of Lrpc Strands Coated With Wax. The Wax Must Be Hand Applied Using Gloves From The Pail Prior To Insertion On Strand In Duct. Powrthrow Ht Wax Is Bipolar In Nature Should Protect The Strand From Corrosion. As Per Jis Z 1535M Method Should Have Excellent Resistance To Corrosion Spots. And The Wax Should Show A Potential Change Of Minimum 120Mv As Per Corrosion Potential Test.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
35.
Defence #10788517 Price Bid
Provision Of 02 Industrial Desert Coolers For 202 Cedu Under Ge U P M Delhi Cantt => Limited; M&L for Supply, Fabrication, Installation, Balancing and Commissioning of Site fabricated GSSsheet metal rectangular ducting with supports as per IS 655-2010complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangerssupports & mounting ,connecting unit to duct ,controller fixation ,joint gasket , nutbolts ,flanges ,cleats etc. of 24 gauges complete all as specified and directed by engineer in charge. - 85 Supply & FixingofAir grills of size 100mm X600mm(imported Air Grills) with auto swing & rust free for life, specially engineered grill for longer airflow & wider angle coverage and upto 50% less sound icluding nuts, bolts, screws ,rubber gasket etc. to make the system complete all as specified and directed by engineer in charge- 10 SQM.Supply, fixing and Commissioning of canvas connector for connection of cooler with ducts complete all as specified and directed by engineer in charge - 02 Each PcM&L for Iron frame stand for mounting of machine & fixing on location all as perthe site requirement made out of angle iron of size as per recommended by manufacturer including foundation where necessary, soldering and required foundation ground support all as directed at site the entire satisfaction of department complete all as specified and directed by engineer in charge. - 250 Kg.M&L for control wiring with 5 coreX 4 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Voltsgrade with multi stranded, wire colour black,drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694complete all as specified and directed. Make : Finloex/Havells/Polycab - 40 RM.Supply & fix Industrial wall mounted plug socket three phase 16 Amp rating 3P+N+E suitable for IP 67 degree of protection all as specified and directed by engineer in charge.Make- L&T/C&S/ABB/HAVELLS - 02 EachMaterial & labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mdeep below the ground level) with top edge of the plate not less than 1.5m belownormal ground level,connected to the galvanised earth lead by means of boltsnuts check nuts and washers of galvanised iron strip of size 25 x 4mmas earthinglead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 40mm dia GI medium gradeearth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) typeA1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handlemade of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugsetc mesh, chorcoal and common salt in alternate layer of 15cm thickincluding testing on completion all as specified and as directed. (Note:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.)-01 Each
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
36.
Rural Development #10787366 Price Bid
Regarding Supply Of Verious Type Of Material At Gram Panchayat Office Hingnakazi P.S. Malkapur Z.P. Buldhana , Miscellaneous Item , Supplying Integrated Led Street Light Fitting26 To 30W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing ,Having System Lumens Output Of Min. 2600 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50,Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf/Fls2. , Supplying 18W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying Integratedled Street Light Fitting 100-110W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing,Havingsystem Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50,Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf/Fls2. , Holder , 2.5Mm 2 Core Flat Cable 660/1100V. , Office Cupboard 19*36*78 , Office Cupboard19*36*54 , Office Table 2*4 , Office Table 2*3 , Computer Table 2.5*4.5 , Table Glass 2*4 , Table Cloth 2.5*4.5 , Office Revolving Chair , Office Revolving Chair Staff , Soft Cousion Chair , Branded Company Celling Fan 48 , Branded Company Wall Fan 400Mm , Branded Company Table Fan 400Mm , Branded Company Pedestal Fan 400Mm , Office Rack 19*36*78 , Fiber Chair , Stool , Dust-Bin 10 Lit (Swing Dustbin Material: Plastic, Color: Any Size: 28 Cm X 28 Cm X 39 Cm Made In India - Resistant To Uv, Heat Extra Strong 100% Virgin (Hdpe) Plastic) , Dust-Bin120 Lit (Material ?Plastic Special Feature ?Wheeled Shape ?Rectangular Product Dimensions ?56L X 49W X 94H Centimeters) , Dust-Bin Set 60 Lit Each With Metal Structure , Tricycle For Garbage Collection (- The Back Side Will Be Opened Manually.Back Side Will Be Raised Manually. All Saport Angle 25X25x2.5 Mm.Main Frame Angle 32X32x3mm.Sheet 20 Gauge.Patti For Saport 18X3mm.) , Electric Auto For Garbage Collection (Container Dimensions (L X W X H) 5 Ft X 3.25 Ft X 3.25 Ft Container Type 1 - Dry Waste, 1 - Wet Waste No. Of Batteries Required 4 (Lead Acid) / 1 (Lithium Ion) Charger 48V 15A) , Hand Wheel For Garbage Collection (Size/Dimension 450 X 700 X 300 Mm Thickness 2 Mm Surface Finish Color Coated) , Fogging Machine (4 Technical Specifications Engineoutput - 10.5 Kw Fule Tank Capacity – (Petrol) 1.2Litter Averagefuleconsumption(Approx)1.2 Litter / Hr Tank Capacity – 5 Litter Weight – 9.0 Kg Powerfulperformersuper Hand Pump Start ) , Satranji , Desk-Bench , Study Table , Metal See-Saw , Metal Sliding , Metal Zula , Branded Company Mixer Grinder , Branded Company Induction Food Macker (Pre-Set Timer For Hassle Free Cooking Warranty: 1 Year Warranty Power: 2000-2100 Watts; Operating Voltage: 220 - 240 Volts) , Branded Company Coocker 12 Lit (Material Aluminium Closure Type Outer Lid Colour Silver Finish Type Aluminium Product Dimensions 30.5D X 30.5W X 40.6H Centimeters) , Steel Bucket 15 Lit , Steel Handa 15 Lit , Steel Plate Medium Size ( Poha Plate ) , Metal Stroage Kothi 100Kg , Try Cycle For Kids , Water Purifier 18 Lit , Water Purifier 50 Lit , Water Jar/Can 18 Liter , Weight Machine , Led Smart Tv 32 Resolution: Hd Ready (1366X768), 2 Usb Ports To Connect Hard Drives And Other Usb Devices, Sound : 20 Watts Output | Dolby Audio, 1 Year Comprehensive Warranty , Led Smart Tv 40 Resolution: Hd Ready (1920 X 1080 Pixels), 2 Usb Ports To Connect Hard Drives And Other Usb Devices, Sound : 20 Watts Output | Dolby Audio, 1 Year Comprehensive Warranty , Led Smart Tv 50 Display: 4K Ultra Hd, 3840 X 2160 Pixelsconnectivity: 3 Hdmi | 2 Usb | Wi-Fi Operating System: Android Sound: 24 W Speaker, Dolby Audio Usp: Farfield Voice Control 1 Year Comprehensive Warranty , Sound System Set (100W Speakers 2 Nos, Wireless Mike 2 Nos, Amplifier 400W ) , Trolly Speaker Connectivity: Bluetooth | Aux | Usb | Memory Cardpower Output: 45Wconfiguration: Stereo Channelpower Source: Ac Adapterusp: In-Built Amplifier |True Wireless Speakers |8 Inches Subwooferwarranty: 12 Months Warranty , Cement Bench 58.4D X 177.8W X 78.7H Centimeters , Metal 3 Seater Bench 58.4D X 177.8W X 78.7H Centimeters , Hospital Bed (Bed Dimension (Lxwxh) Is 198 X 90 X 60 Cm, 1 Pcs Semi Fowler Bed , 1 Pcs Handles,) , Bed Side Locker (The Locker Is Made Of High-Quality Crca (Cold-Rolled Close Annealed) Steel, Which Is Known For Its Durability And Strength. The Dimensions Of The Locker Are 425 Mm X 425 Mm X 825 Mm, Making It Compact And Easy To Move Around.) , Examinaton Bed For Hospital ( Material:Â Mild Steel, Size:Â 1800 Mm X 600 Mm X 800 Mm,Drawer Size:Â 300 Mm X 300 Mm X 150 Mm,Footstep Size:Â 400 Mm X 400 Mm) , Jal Drop , Handwash Station , Supplying 230/250V, 50Hz, Evaporative Air Cooler (Desert Cooler) Duct Type Having Normal Cooling Capacity Of 100Cu.M Per Minute, With 15 Exhaust, Min 75 To 80 Litres Water Capacity Tankwith Galvanised Steel Sheet With Grade 350 Minimum, Leak Or Drip Free, Front Grill Shall Be Made Of Non-Corrosive Material, Circular Opening Shall Be More Than Fan Sweep Butnot Exceeding More Than 25Mm, Filter Pads Shall Be Made Of Wood Wool Or Any Other Substitute Placed In Non-Corrosive Wire Mesh And Tightened At Places With Side Panels, Noise Level Should Not Be More Than 65Dba At 1M Distance, 3 Core Copper Cable Minimum 2M Length & Metal Casing Of The Electrical Components, Metal Frame Or Chassis Of Cooler Cabinet And All Exposed Metallic Parts, Shall Be Provided With Proper Earthling Complete As Per Specification No. Ap-Wcr/Dac , Ladder 240 Inch , Bleaching Powder , Cement Tank For Water Storeage , Indian Hon. Leader Photo Frame 8*12 , Solar Light System With 4 Meter Pole, 15W Light, Having 12 Hour. Battery Backup Auto Deaming, , All In One Computer (Processor: 10Th Gen Intel Core I5-10210U | Speed: 1.6 Ghz Memory And Storage: 8Gb Ddr4 Ram Storage: 512Gb Ssd Display: 23.8Inch Full Hd (1920X1080) , All In One Printer (Printer Type: Functions: Print, Scan, Copy ; Printer Output: Monochrome ; Connectivity: Usb ; Scanner: Yes ; Scanner Resolution: 600 X 600Dpi Mobile Connectivity : No ; Hardware Interface: Usb 2.0 Hi-Speed ; Enlarge/Reduce Option: No ; Duplex: No Warranty - 1 Year Warranty ) , 1000Lph Capacity Semi Automatic Ro Plant 1)Raw Water Pump 1.0 Hp 2)Sand Filter 13 Dia* 54Mm 3)Carbon Filter 13 Dia* 54Mm 4)Micron Filter 5 Mic 20 (2Qty) 5)High Pressure Pump 1000 Lph 2 Hp 6)Control Panel 7)Anti Scalatant Dosing Pump 0 To 6 Lph 8)Rota Meter 0 To 2400Lph (2Qty) 9) Pressure Guagee 0 To 7 Kg/Cm2 (2Qty) 10)Membrane 4040 (4 No.) Or 8040 (1 No.) 10)Ss Pressure Vessel 4080 (02Qty) Or 8040 (1Qty) 12)High Pressure Switch 13)Low Pressure Switch 14)Floaty 15)Uv System , Installation, Transportation, Loading, Unloading, Pipes, Accessories Fitting Etc. For 1000 Lph Ro System. , Pvc 3 Layer Food Grade Tank 1000 L , Water Atm Machine Card + Coin , Atm Card , 5 Kva Stabiliser For Ro And Chiller , Providing And Installation Of Chiller Plant Of 2 Tr Capacity , Fogging Machine Medicin , Frc Urinal Cabin 3*3*7 (Lxwxh) Feet , School Bag , School Uniform 22No. , School Uniform 24No. , School Uniform 26No. , School Uniform 28No. , School Uniform 30No. , Pvc Pipe 75Mm 4Kg , Pvc Pipe 75Mm 6Kg , Pvc Pipe 90Mm 4Kg , Pvc Pipe 90Mm 6Kg , Pvc Pipe 110Mm 4Kg , Pvc Pipe 110Mm 6Kg , Pvc Pipe 160Mm 4Kg , Pvc Pipe 160Mm 6Kg , Supplying, 1 Kwp Off-Gridsolar Power Pack Withinterconnectingwires / Cables Up To 12 V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 03 Nos.), C-10 Rated Lead Acid Battery Bank 12 V, 400 Ah (12V, 100 Ah X 4 Nos.)Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Holdbattery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board , Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying,3 Kwp Off-Gridsolar Power Pack With Interconnecting Wires / Cables Up To 24 V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 09 Nos.), C-10 Rated Lead Acid Battery Bank 24 V, 600 Ah (12V, 300 Ah X 4 Nos.)Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Hold Battery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty Andfully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying 5 Kwp Off-Gridsolar Power Pack Withinterconnectingwires / Cables Up To 24V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 15 Nos.), C-10 Rated Lead Acid Battery Bank 24V, 300Ah X 4 Nos. (12V, 300 Ah X 8 Nos)Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Holdbattery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping,Display Board, Sign Board, Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying, Installing, Testing And Commissioning Of 3 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 09 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping,Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card / Chip For 5 Years Including Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of5 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 15 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of10 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 30 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of 15 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 45 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of20 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 60 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping,Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong. , Supplying, Installing, Testing And Commissioning Of25 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 75 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card / Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong. , Supplying, Installing, Testing And Commissioning Of100 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 300 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card / Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty Andfully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong. , Supplying And Erecting 12V/200Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 2500 Va Digital Pure Sine Waveinverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technologycompleteas Per Specification No.Ap-Inv , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 10Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipeas Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core16sq. Mm.Aluminium Conductor Completeerected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipeas Per Specification No. Cb-Lt/Al , Supplyinganderectingsingle Phase 10 To 60 A Net Meter Of Accuracy Class 1.0, 240V, 50 Hz,With Backlitlcd Display, Optical Port ( Measures Import Kwh, Export Kwh, Net Kwh, V, I, Kw, 12 Months History Of Energy)With Wiring Connections And Mountinghardwareonprovidedpanelscompletewith Calibration Certificate From Manufacturer. , Supplyinganderectingiron Work, Sheet Metal Work Consisting Of Crcasheets, Varioussectionsofiron,Plates, Chequeredplates,Rods,Bars,Mspipes,Etc. Forpanel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Completeerectedatthepositionwith Necessarymaterialsdulypaintedwith One Coat Of Red Oxide And Two Coats Of Enamelpaint To Match The Switchgears Or As Per Directions By The Authority. , Supplying, Installing, Testing & Commissioning Split Type Variable Speed Invertertechnology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Trcapacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump (Monoblock), 230V, Single Phase 50 Cycles A.C. Supply Of0.375 Kw/0.5 Hp With Discharge 285/67 Litres Per Minute (Lpm) For Head Of 6/13.8 M& 40 Mm Suction/ 40 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp , Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Of 2.25 Kw/3 Hp With 415 V, 50 C/S Ac Supply Suitable For 150 Mm Dia. Borewell Suitable For 120 To 475 Lpm Discharge At 36 To 10 M Head & Discharge & Delivery Pipe Of Size-50 Mm Diameter With A Necessary H Type Clamps As Per Specification No. Wp-Smp , Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Suitable For Erection On Open Well Of 5.625 Kw/7.5 Hp With 415 V 50 C/S. A.C. Supply, Having Delivery Head From 57 To 22 M And Discharge From 120 To 900 Litres. . Per Minute & Pipe Of Suction 75 Mm/Delivery 65 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp , Supplying & Erecting Flat Flexible 3 Core 10Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , 5000 Lit Water Tanker , Resistance Bands , Treadmills , Free Weights , Battle Ropes , Rowing Machines , Ellipticals , Weight Benches , Power Racks , Cable Machines , Cardio Equipment , Suspension Trainers , Weighted Sleds , Stability Balls , Dumbbells , Lat Pulldown Machine , Chest Press , Pearl Delt/Pec Fly , Butterfly , Shoulder Press , Lateral Raise , Fixed Pulldown , Lat Pulldown , Rowing Machine , Biceps Curl , Triceps Extension , Dip / Chin Assist , Leg Press , Leg Extension , Adjestable Extra Weight Plate 5Kg Set , Shev Peti 3*3*7.5
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
37.
Public Administrative Department #10778213 Price Bid
Tender For Construction Of Kriya Ghar Situated At Swaraj Nagar Ward 57 Panki Kanpur - Earth work in excavation by mechanical means (Hydraulic excavation)/ manual means in • foundations trench or drain (not exeeding 1.5m in width or 1Osqm on plan) excavated soil as directed within a lead of 50m incl. dressing of sides and ramming of bottom lift upto 1.5m incl. getting out the all kind of soil 2 P/Laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level- 1:6:12( l Cement : 4 Coarse sand zone-111 :8 grade stone aggregate 40inm nominal size 3 Brick work with common burnt clay non modular bricks of class 150 in foundation and plinth in: Cement mortar 1:4 (1 Cement : 4 mortar) 4 P/L in position cement concrete of specified grade excluding the cost of centeringshuttering-All wrk up to plinth level 1:1.5:3 cement, co sand & 20mm stone aggregate nominal size 5 Providing and layig damp proof course 25inm thick with cement concrete 1:2:4 (l cement :2 coarse sand (zone -III ):4 graded stone aggregate 12.5mm nominal size) 6 RCC work in beams, suspended floors, roofs having slop up to 15 landing, balconies, shelves, chajjas, lintels, bands, plaing window sill staircases and spiral stair above plinth level upto floor five level excluding the cost of cerering shuttering finishing and reinforcement with 1:1.5:3(1 cement:1.5coarse: 3 graded stone aggregae) 7 Centering and shuttering including strutting, proping etc, and removal of foundation, footing, bases of columns etc of mass concrete 8 Suspended floors, roofs,landing, balconies, access platform 9 Steel reinforcement for RCC work including straitening cutting bending placing in position and binding all complete upto plinth levelThermo Mechanically Treated bars of grade Fe-500D 10 Brick work with common burnt clay non modular bricks of class 150 in foundation and plinth in: Cement mortar 1:4 (1 Cement : 4 mortar) 11 P/L of G.S.B with road aggregate including spreadingin uniform thickness, hand packing, rolling with 3-wheeled steel/vibratory roller 8-10 tones in stages to proper grade and camber, applying and brooming requisite type of screening binding materials to fillup the intersitces of coarse aggregates, watering and compacting to the required density 12 p/l 80mm thick interlocking tiles with stone dust including etc all comp 13 Cement concrete flooring 1:2:4(1 cement : 2 coarse : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry etc all comnplete 40mm thick with 20mm nominal size stone aggregate 14 12 mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) plaster including etc all comp 15 Finishing wall with putty appreoved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material labour T&P etc. required for proper competion of work 16 Finishing wall with exterior paint(Apex) of approved brand and manufacture and of required shade on undacorated wall surface to give een shade over @1.25Ltr/10sqm including one coat of primer [email protected]/10sqm coat curing and cost of all material, labour T&P etc required for proper completion of work 17 P/L virtied tile in diferent sizes (thickness to be specified by the manufactrer) with water absorption less than 0.08@ and conforming to IS:15622] of aproved make, in all colurs and shadesize of tile 600x600mm 18 P/F 1mm thick M.S sheet door with frame of 40x40x6mm angle iron and 3 mm M.S gusset plates at the junction and corners, all necessary fittings, complete, including applying a priming coat of approved steel primer.Using M.S anglels 40x20x6mm for diagoinal braces 19 P/F M.S Tube Frame approved size by welding etc to sheet ladder railing, balcony, gate, railin, staircase railing and similar works including applying priming coat of approved steel primer-M.S Tube 20 P/L precoated galvanised iron profile sheets(size, shape and pitch of corrugation as approved by Enginner-in char) 05mm total coated thickness with zince cooating 120gm per sqm as per IS:277, primer on both side of the sheet and plyester top coat 15-18microns. Sheet should have protective guard film of 25microns minimum to avoid scrateches during transportatin and should be supplied in single length upto 12m or as directed by Engineer-in charge. 21 Painting 1st coat over priming coat (but excluding cost of priming coat) on steel and other metal surfaces upto 10cm width or grith or small articles not exceeding 0.10 sqm. In area Hi glaoss Apcolite, Superlac Dulux dspecified brushing to give and even shade and including the cleaning the surface of all dirt, duct and othe foreingn material sand papering and scrapping incl. cost of all material. labour, tools and plants, etc required for proper completion of work Extra over item 2 and 2(a) above but for every coat on previously painted old surface 22 Supply and fixing of RCC bench including etc all complete 23 S/F of 150mm Ventilating Fan all complete as per drawing and specification and direction of engineer in charge, Make-Crompton, Havells, Bajaj or Equivalent AB 24 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm RFLSPVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. One light point with 5Amp, switch, Group C 25 S/F suitable size GI Box with modular late and cover in front on surface ow in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular swithc, connection et, as required 26 S/F of power plug with 20Amp/250 volt flush type modular switch and 5 pin 20A250 volt flush type universal modular socket switch on concealed M.S box including supply of all 27 Supply and fitting of ceiling fan Usha, khetan, Bajaj ISI including all complete 28 Supply and installation 1.5 hp submercible pump incl. etc all comp 29 P/F wate closet squatting pan with 100 mm sand cast iron P or S trap, 10litre low level with P.V.C flusing cistern incl. flush pipe, with manuale flusingcistern incl. flush pipe with manuale controllerd devie handel lever and confroming to IS: 7231 with all fitting and fixtures compl. incl. cutting and making good the wall and floor whereever requiredwhite vitrous chine orissa pattern W.C pan size 580x440mm with intral type foot rests 30 Providing and fixing wash basin with ci brackets 15mm CP brass waste of standard patten, including painting of fitting and bracket cutting and making good the wall whereever required white vitreous china wash basin size 630x450mm with a pair of 15c.p bracket pillar type 31 Providing and fixing pvc waste pipe from sink orwash basin including pvc waste fitting complete, semi rigid, 32mm dia/40mm di, CP Brass fitting 32 Providing and fixing unplastic PVC connection pipe with brass unions, 45cm length, 15mm nominal Bore 33 Providing and fixing CP brass long nose bib cock of approved quality weighting not less than 80grms15mm nominal bore 34 CPVC pip 150mm inner dia including filtering etc all complete 35 PVC water storage tank syntre or equivalent 36 PVC pipe 75 mm dia ISI Marked (working pressure 4kg/sqcm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
38.
Agriculture #10759745 Price Bid
1 Supply, installation, testingand commissioning of 30 KVA, 3 Phase, 415 V AC, 50 Hz, 0.8 PF (lag), Silent DG Set (CPCB IV+) comprising of Engine coupled with alternatormounted on a common base frame. The DG set shall comprising of following; 1) The Engine (confirming to IS 10002) developing minimum 42 BHP at 1500 RPM, liquid cooled with radiator and fan, Turbo charged, powered by minimum four (4) strokes, multi cylinder, shall be automatic electric starting by 12 V DC starter motor system (battery capactity 90 Ah) and fitted with Electronic Governor (confirming to IS 10000) 2) DG set is capable of delivering an output of 10% in excess of rated KVA for a period of 1 hr in any period of 12 hrs continous running.3) The alternator (confirming to IS 4722) shall be brushless type, self-excited and self-regulated. The alternator must be provided with IP 23 protection with class-H insulation.Alternator efficiency at 100% load (0.8 pf) is not less than 88% and maximum voltage dip at full load (0.8 pf lag) is less than 20%.4) Instrument Control Panel shall be furnished for the engine and shall be comprising of Push Button, Water temperature gauge, Hour meter with RPM indicator, Lube oil pressure gauge.5) DG set complete with Acoustic enclosure shall be made of Pre-treated and Powder coated CRCA Sheet with vermin proof. Along with Residential Silencer and noise level less than or equal to 75 db at a distance of 1 m from of Acoustic enclosure (confirming toIS 8528- 10). DG accoustic enclosure shall have inbuilt fuel tank of minimum 70 litres capacity and fuel piping (between fuel tank and diesel engine), valves, level indications, oil filter and allstandard accessories. MS pipes, heavy class of suitable dia shall be used for fuel piping . Glass window on acoustic enclosure in front of the control panel and emergency stop switch outside the acoustic enclosure.6) DG set should be provided with remote monitoring system to share real time genset information and can be acceseed via mobile device or desktop.7) AVM Pads as per engine manufacturer standard shall be provided for DG set.8) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided.9) Type Approval Certicate (as per CPCB IV norms) for the specified rating of the Power Generator from any of the designated agency authorized by CPCB,Type test report for Alternator latest to conform the specications. Company warranty certificate for 2 years on complete DG set shall be provided. 2 Fabrication, Supplying, Installation, Testing & Commissioning of AMF control panel. The Panel shall be free standing, floor mounted, metal clad cubicle type in construction, to form a compact assembly in dust / damp and vermin proof type, equivalent to IP-53. The thickness of sheet steel members shall not be less than 1.6 mm for cold rolled steel. AMF panel shall be complete with all accessories such as changeover Contactors/MCCBs having sufficient rating, AMF relays etc. for auto changeover of supply from Grid to DG set and vice-versa. Electrical Protections shall be provided through Numerical relays. Required CTs & PTs for metering and protection shall be included. All necessary control and supervisory equipment for the automatic operation of the set shall be included in the panel. Suitable rating of MCCB with over-load and short-circuit protection shall be mounted in the Control Panel for the isolation of loads. MCBs shall be provided for the isolation / protection of control circuit. AMF panel shall be equipped with meters displaying the parameters like Voltage,current , frequency, speed, KVA, KW, Power Factor, fuel Level, Engine running hour counter,Lube Oil Pressure and Engine temperature, etc. 3 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 4 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 5 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 6 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 7 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. 8 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 9 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 10 All kinds of soil 11 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 13 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 14 Centering and shuttering including strutting, propping etc. and removal of form for 15 Foundations, footings, bases of columns, etc. for mass concrete. 16 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. 17 Thermo-Mechanically Treated bars of grade Fe-500D or more. 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 19 Cement mortar 1:4 (1 cement : 4 coarse sand) 20 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 21 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 22 6 mm cement plaster of mix : 23 1:3 (1 cement : 3 fine sand) 24 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 25 Hot finished welded type tubes. 26 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of total thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 27 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 28 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 29 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 30 Supplying ofXLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date ammendments of the following sizeas required. 31 3.5 x 50 sq. mm 32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 33 3½ X 50 sq. mm (35mm) 34 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 35 Above 35 sq. mm and upto 95 sq. mm 36 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 37 Above 35 sq. mm and upto 95 sq. mm 38 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 39 Above 35 sq. mm and upto 95 sq. mm 40 Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
39.
Drinking Water Supply and Sanitation #10713558 Price Bid
Different Works Related To Water Supply Scheme At Duna & Its Adjoining Mouzas Water Supply Scheme Within Mayureswar-Ii Block Including Supply Of All Labour & Materials Underbirbhum Division, Phe Dte. ( Sl. No.11 ) - Sinking Of Tubewell- 3 Nos. ( Annexure I ) Site Preparation, Temporary Latrine, Placement & Levelling Of Rig Machine, Mast Hoisting And Casing Drilling ( Upto 6 Mtr. ) Placement Of Casing With All Allied Works Necessary To Commence Drilling Woks And Wind Up Of All Machineries After Completion Of Drilling. 2 Drilling By Direct Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Ratefor Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Ratefor Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Ratefor Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate. From 6 Mtr. To 60 Mtr. 3 From 60 Mtr. To 90 Mtr. 4 From 90 Mtr. To 120 Mtr. 5 From 120 Mtr. To 150 Mtr. 6 From 150 Mtr. To 180 Mtr. 7 Lowering The Tube Well Assembly ( Upvc Casing Pipe , Well Pipe, Strainer Along With Upvc Accessories ) Vertically In A Position With Proper Lowering Arrangement By Applying Necessary Jointing Compound Including Labour Cost For Subsequent Gravel Packing And Machine Operation Cost Etc. 8 Cost Of Consumables For Drilling Rigs And Machineries. 9 Development ( Min. 8 Hr. Continuous ) Of Tube Well By Using Suitable Air Compressor ( Min. Capacity: 600Cfm & Operating Pressure 14 Bar ) Followed By Yield Testing With Bht Pump ( Head :45 To 50Mtr., Discharge :1100 To 1000 Lpm And 25 Bhp Engine ) All Complete Includingto & Fro Transportation Cost And Cost Of Fuels, Lubricants & Labour Etc. 10 Water Sample Collection And Chemical Test Including Arsenic Test. 11 Transportation Cost Of Drilling Equipmentand Accessories Rig Machine Etc. Including Cost Of Fuel, Lubricant & Loading Unloadingthe Materials From Store / Stack Yard / Suppliers Godown And Unloading / Stacking The Same At Site. ( Upto 60.0 Km Distance ) 12 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 250 Mm Dia. ) 13 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 150 Mm Dia. ) 14 Supply And Delivery Of Upvcdeep Well Screen ( Rds ) Pipes With Ribs Conforming To Is 12818:2010 . ( Cipet Certified ) 150 Mm Dia. 15 Supply And Delivery Ofupvcreducer 250Mm X 150Mm Dia. 16 Supply And Delivery At Site Of Upvc End Cap. ( 250 Mm Dia. ) 17 Supply And Delivery At Site Of Upvc End Cap. ( 150 Mm Dia. ) 18 Supply And Delivery Of M.S. Housing Clamp 250 Mm Dia. 19 Supply And Delivery Of M.S .Centre Guide ( Special Type ) . 20 Supply And Delivery Of Washed Gravels Size Ranging From 1.80 Mm To 4.74 Mm. Conforming To Is 4097 : 1967. 21 Supply And Delivery Of Bentonite Powder Conforming To Is 6186 : 1986. 22 Electro-Logging Charge. 23 Trial Boring Of Tube-Welldrilling By Reverse Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Rate For Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Rate For Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Rate For Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate.From G.L. To 60 Mtr. 24 From 60 Mtr. To 90 Mtr. 25 From 90 Mtr. To 120 Mtr. 26 From 120 Mtr. To 150 Mtr. 27 From 150 Mtr. To 180 Mtr. 28 Cleaning Compound Premises Of Shrubs, Plants, Jungled Etc. As Per Direction Of E.I.C. 29 Soil Test For Ohr- 1 No. ( Annexure Ii ) Mobilisation Charges Of All Tools & Plants Along With Accessories, Material, Labour, Supervision Etc. At Site Of Work Required In Connection With Boring And Testing Work, Including Setting Up Boring Rigs And Shifting To Different Bore-Hole Points Etc. And Also Including Withdrawal Of Same From The Site After Completion Of Work, Complete As Per Direction Of Engineer-In-Charge. 30 Labour For Making Bore-Holes Of 150Mm To 250Mm Dia. By Any Standard Method To Any Depth Below Ground Level / Bed Level In All Kinds Of Soil Like Clay, Silt, Sand, Stiff Clay, Mixed Soils Etc. Except Rocks ( For The Purpose Of Collecting Disturbed & Un Disturbed Soil Samples, Conducting Standard Penetration Test At Suitable Intervals Etc. ) Including Preparation And Submission Of Bore-Log As Per Irc : 75 And 78 And Clause 2400 Of Specifications For Road & Bridge Works ( 5Th Revision ) , Published By Irc, And Also Including Hire Charges Of Tools And Plants Complete As Per The Direction Of Engineer-In-Charge.A ) When Casing Pipe Is Used To Prevent Collapse Of Bore Hole ( Casing Pipe To Be Finally Withdrawn ) I ) Depth 0 M To 10 M ( For 3 Nos Bore ) 31 Ii ) Depth Greater Than 10 M & Upto 20 M 32 Iii ) Depth Greater Than 20 M & Upto 30 M 33 Field Investigation :I ) Collection Of Undisturbed Soil Sample From The Bore Hole To Be Made By The Concerned Division / Party At Their Cost.A ) 0.00 - 10.0 M 34 B ) 10.00 - 20.0 M 35 C ) 20.00 - 30.0 M 36 Ii ) Collection Of Samples From The Bore Hole ( A ) Disturbed 37 Iii ) Standard Penetration Tests ( S.P.T. ) By Split Spoon Sampler In The Bore Hole As Per Is : 2131.A ) 0.00 - 10.0 M 38 B ) 10.00 - 20.0 M 39 C ) 20.00 - 30.0 M 40 Laboratory Investigation :I ) Liquid Limit As Per Is 2720 ( Part – V ) . 41 Ii ) Plastic Limit As Per Is 2720 ( Part – V ) 42 Iii ) Grain Size Analysis By Sieving As Per Is 2720 ( Part – Iv ) . 43 Iv ) Grain Size Analysis By Hydrometer Method As Per Is 2720 ( Part – Iv ) . 44 V ) Determination Of Water Content As Per Is 2720 ( Part – Ii ) . 45 Vi ) Determination Of Specific Gravity As Per Is 2720 ( Part – Iii ) . 46 Vii ) Direct Shear Test As Per Is 2720 ( Part – Xiii ) . 47 Viii ) Determination Of Unconfined Compressive Strength As Per Is 2720 ( Part-X ) ( I ) Undisturbed 48 Ix ) Determination Of Consolidation Properties As Per Is 2720 ( Part – Xiv ) . 49 X ) Tri-Axial Shear Test :A ) Determination Of Shear Strength Parameters Of A Specimen Tested Inunconsolidated Undrained Tri-Axial Compression Without Measurement Ofpore Water Pressure As Per Is 2720 ( Part –Xi ) . 50 Carriage Of All Disturbed & Undisturbed Samples From Site Of Work To The Divisional Office Or Elsewhere Including Loading And Unloading As Per Direction Of Engineer-In-Charge. Detailed Investigation. 51 Preparation And Submission Of Report In 6 ( Six ) Copies, Giving All Relevant Information Data Like Site Plan, Bore Log And Water Table, Test Results, Calculations, Discussions, Suggestions And Recommendations In Respect Of Suitable Foundation Etc. Including Determination Of Silt Factor Calculation Of Waterways And Complete Design Of Foundation Including Analysis Of Bearing Capacities And Settlements In Bound And Presentable Form Complete As Per Direction Of Engineer-In-Charge.Detailed Investigation. 52 Construction Of 300 Cum Ohr- 1 No. ( Annexure Iii ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete. A ) Depth Of Excavation Not Exceeding 1500 Mm 53 B ) Depth Of Excavation For Additional Depth Beyond 1500Mm And Upto 3000Mm. ( But Not Requiring Shoring ) . 54 Bailing Out Water From Foundation Trench. This Item Should Be Executed On The Specific Direction Of The Engineer-In-Charges When He Is Satisfied In His Absolute Discretion, That This Has Not Been Necessitated Due To Any Fault On The Part Of The Contractor ) 55 Hire And Labour Charges For Shoring Work ( Including Necessary Close Plank Walling, Framing, Eucalyptus / Jhau Balla Pilling, Strutting Etc ) Complete As Per Directionof The Engineer-In-Charge For Foundation Excavation ( Vertical Surface Are In Contact With Supported Earth Is To Be Measured. ) ( This Item Should Be Executed On Specific Direction Of The Engineer-In-Charge ) .A ) Depth Upto 1.5M. 56 B ) For Additional Depth Beyond 1.5M And Upto 3.00M. 57 Earth Filling In Foundation Trenches Or Plinth With Good Earth In Lyres Not Exceeding 150Mm Including Watering & Ramming Etc Layer By Layer Complete.A ) With Earth Obtained From Excavation Of Foundation. 58 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. ( Payment To Be Made On Measurement Of Finished Quantity ) Do - By Fine Sand 59 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level, And Filling Joints With Powered Earth Or Local Sand. 60 Cement Concrete With Graded Stone Chips ( 20Mm Size ) Excluding Shuttering, In Ground Floor ) Considering 30 Km Distance From Suri Rly. Yard.A ) 1:2:4 Proportion. ( In Foundation And Under Tank At Finished Gl, Plinth Protection Etc. ) 61 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) .Considering 60 Km Distance From Suri Rly. Yardm- 25 Grade ( With Pakur Variety. ) A ) For Works In Foundation, Basement And Upto Roof Of Ground Floor / Upto 4M. 62 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 63 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 64 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 65 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 66 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 67 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) . Considering 60 Km Distance From Suri Rly. Yardm- 30 Grade ( With Pakur Variety. ) A ) Heal Beam And Above ( Cell Wall, Floor, Top & Bottom Ring Beam, Heal Beam ) A ) 6Th Floor 68 B ) 7Th Floor 69 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4M Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness And Required Bracing For Concrete Slabs, Beams, Column Lintel Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Woks ( Upto Roof Of Ground Floor ) .Steel Shuttering Or 9 To 12Mm Thick Approved Quality Ply Board Shuttering In Any Concrete Work.C ) For Foundation Upto G.L. 70 Hire And Labour Charges For Shuttering For Concrete Work In Overhead R.C. Reservoir On Separate R.C. Frame Including Fitting, Fixing And Striking Off After Completion Of Work Including Staging Upto 4M Using Ply Board Or Steel Shuttering. ( Not Applicable For Resting On Roof Top ) .A ) G.L. To Top Lantern Of Ohr. 71 Hire And Labour Charges For Staging Beyond 4M With Necessary Cross Bracing And Fixtures And Removing The Same After Completion Of The Work All Complete As Per Direction Of The E.I.C. [ Mode Of Measurement :Area Of Unsupported Horizontal Projection ( Where Staging Beyond 4M Is Practically Un-Avoidable ) X Mean Height Of Staging ] Above Initial 4M. ( Dia 10.50 M. Mean Height 16M. ) 72 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction. I ) Tor Steel / Mild Steeli. Sail / Tata / Rinl A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . 73 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 74 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 75 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 76 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 77 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Top Of Heal Beam 78 G ) 6Th Floor I.E. From Top Of Heal Beam To Top Ofshell Wall 79 H ) 7Th Floori.E. From Top Of Shell Wall To Rest 80 Applying 2 ( Two ) Coats Of Bonding Agent With Synthetic Multi Funtional Rubber Emulsion Having Adhesive And Water Proofing Properties By Making With Water In Proportion ( 1 Bonding Agent : 4 Water : 6 Cement ) As Per ManufacturerS Specification. 81 Extra Rate For Using Water Proofing And Plastering Admixture @ 0.2%By Weight Of Cement ( Or At ManufacturerS Specified Rate For Concrete Of Various Grades ) . 82 Supplying, Fitting, Fixing Fly / Mosquito Proof Nylon Net On Any Type Of Window, Doorshutter Frame With Necessary Fixing Arrangements Complete. 83 Supplying Fitting And Fixing Door Made With Irc Febric Mesh Of 75Mm X50mmx4.5Mmx2.7Mm On 50Mm X 50Mm X 6Mm Angle Iron Frames All Round And One 37.5Mm X 6Mm M.S. Flat Bar Over The Netting All Round Welded To Angle Iron Frame And Providing Locking Arrangements If Necessary And With Two Coats Of Synthetic Enamel Paint ( Other Than Hi-Gloss ) Fitted And Fixed With Clamps Or Haskal Doomney Etc. Complete At The Lantern Of R.C.C. Over Head Reservoir. 84 Artificial Stone In Floor, Dado, Staircase Etc. With Cement Concrete ( 1:2:4 ) With Stone Chips, Laid In Panels As Directed With Topping Made With Ordinary Or White Cement ( As Necessary ) And Marble Dust In Proportion ( 1:2 ) Including Smooth Finishing And Rouding Off Corners And Including Raking Out Joints Or Roughening Of Concrete Surface Andapplication Of Cement Slurry Before Flooring Works, Using Cement @ 1.75 Kg / Sq.M. All Complete Including All Materials And Labour.In Ground Floor 3 Mm Thick Topping ( High ) Polishing, Grinding On This Item Is Not Permitted With Ordinary Cement ) .25 Mm Thick.A ) In G.F For Plinth Protection And Under Tank Floor 85 B ) 6Th Floor 86 C ) 7Th Floor 87 M.S. Structural Works In Columns, Beams Etc. With Simple Rolled Structural Members ( E.G. Joists, Angle, Channel Sections Conforming To Is: 226, Is: 808 & Sp ( 6 ) - 1964 Connected To One Another With Bracket, Gussets, Cleats As Per Design, Direction Of Engineer-In Charge Complete Including Cutting To Requisite Shape And Length, Fabrication With Necessary Bolting, Metal Arc Welding Conforming To Is: 816- 1969 & Is: 1995 Using Electrodes Of Approved Make And Brand Conforming To Is:814- 2004, Haulage, Hoisting And Erection All Complete. The Rate Includes The Cost Of Rolled Steel Section, Consumables Such As Electrodes, Gas And Hire Charge Of All Tools And Plants And Labour Required For The Work Including All Incidental Chages Such As Electricity Charges, Labour Insurance Charges Etc. Payment To Be Made On The Basis Of Calculated Weight Of Structural Members Only In Finished Work As Per Is Specified Weight. Payment For Gusset, Bracket, Cleat, Rivets, Bolts And Nuts May Be Make By Adding The Actual Weight Of Such Items With The Weight Of Finished Structural Members Or 7% Of Weight For Finished Structural Members Weighing Not Less Than 22.5 Kg. / M. Or 15 % Of Weight For Finished Structal Members Weighing Less Than 22.5 Kg. / M. May Be Increased Allow For Bracket, Cleat, Rivet, Bolts And Nuts Etc. And No Seperate Payment Being Made For These Items, As Per Direction Of Engineer In Charge. The Rates Are Considered For A Height Of Erection 8M. / 2Nd Floor Level From The Ground. Add 1.5% Extra Over The Rate For Each Additional Floor Or 4M. Beyond Initiial 8M. Or Part Thereof.Iii ) For Built Up Sections / Srtuctural Members Of Specified Sections Weighing Not Less Than 22.5 Kg. / M 88 M.S. Gate Of Jail Type As Per Approved Design Made Of Strong M.S. Frame Work, Intermediate Stiffeners And Round / Square Bars Or Angles. M.S. Sheet ( Not Less Than 14 Gauge ) Gussets, Cleats Etc. Including Necessary Riveting, Bolting, Welding, Locking And Hanging Arrangements, Fitting And Fixing Complete As Per Direction Of The Engineer-In -Charge. 89 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor.A ) Grill Weighing Above 10 Kg / Sqm Upto 16 Kg / Sqm ( In Kg ) 90 Supplying, Fitting, Fixing900 Mm High G.I. Pipe Railing For R.C.C Stair Cat Ladder Walk Way Fabrication, Erection, Welding Of 40 Mm G.I ( Non Tata Medium ) Pipe Place At Top Of Railingand2 Nos 25 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed Equally In Between Railingtop & Floor, Vertical Post Of Raillingare 40 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed At 900 Mm C / C . The Each End Of The Vertical Post Is Join By The 62 Mm ( 25 Mm X 6 Mm X 0.062 M Long ) Ms Flat And 150 Mm Length ( Propes Pipes ) Are Grouted In Concrete Base Of Stair, Walk Way Etc. All Complete With Supplying Of All Materials Including Hoisting Up To The Any Height Complete With 2 Coats Of Painting With Super Gloss ( Hi Gloss ) In Any Shade Except White And Black Over A Coat Of Primer Complete As Per Direction Of E.I.C.Analysis Of Rate Enclosed In Seperate Sheets. ( Analysis Rate ) 91 Supplying At Site Hoisting, Fitting, Fixing Erecting And Building In Position Where Necessary 450Mm.Wide Ladder As Per Design Consisting Of 2Nos. M.S.Plate Of 8Mm.Thick With Necessary Base Plate 60Mm Wide; And 16Mm.Dia M.S.Round Or Square Bar As Steeps Placed @ 300 C / C Including Fabrication, Welding Drilling Etc. As Per Drawing And Direction And Finished With Two Coats Of Synthetic Enamel Painting Over A Coat Of Red Lead Primer Etc. All Complete As Per ;Direction Of The Eic 92 Supplying Fitting And Fixing In Position C.I Manhole / Pit Cover With Rim.A ) Square.I ) 600 X 600Mm ( 50Kg.Approx ) . 93 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 94 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:4 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) G.L. To Top Of 1St Bracing 95 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 96 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 97 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 98 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 99 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 100 G ) 6Th Floor I.E.From Bottom Of Heal Beam To Top Of Ring Beam 101 H ) 7Th Floori.E. From Ring Beam To Rest 102 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:3 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) 6Th Floor 103 B ) 7Th Floor 104 Supplying & Installation Of Lighting Solid Conductor Rod Of Phosphorous-Bronze Size 2M X 12Mm On The Top Dome Of The Rcc Overhead Reservoir, Laying Lightning Conductor Of 65Mm X 8Mm G.I. ( Hot Deep ) Ms Flatruns From The Roof Upto Gl Along The Shell Wall And Colume Fitted With Necessary Rust Proof Clamps, Lying65mm X 8Mm G.I. ( Hot Deep ) Ms Flat Conductorfrom Gl To Bottom Of The Earthing Main Pipe 80Mm Dia. Tata ( M ) Fitted And Fixedand Connecting With The Main Earthing Gi Pipe Of 80Mm.Dia Tata ( M ) Of 2.50M To Be Used As Earthing Electrode Driven Down To At Least 3.0M Below Gl And Filling Up With Charcoal, Construction Of Masonry Chamber Making As Per Direction Of Eic & Necessary Arrangement For Testing The Same As Per Iee Rule. ( All Work To Be Done As Specification Of Pwd ( Elec. ) Schedule. ) 105 Provision For Embossing The Name And Capacity Of The Reservoir With ( 2:1 ) Raised Sand Cement Plaster With Letter Size 30Cm. X 20Cm. On The Outside Of Shell Wall Of The Reservoir Painted Complete As Per Direction Of Eic. 106 Protective And Decorative Acrylic Exterior Emulsion Paint Of Approved Quality, As Per Manufacturer’S Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required. The Rate Includes Cost Of Material, Labour, Scaffolding And All Incidental Charges But Excluding The Cost Of Primer. ( Two Coats. ) I ) Super Protective 100% Acrylic Emulsion.A ) G.L. To Top Of 1St Bracing 107 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 108 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 109 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 110 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 111 F ) From Top Of 5Th Bracing To Top Of Heal Beam 112 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 113 H ) From 1 / 3Rd Of Shell Wall To Rest 114 Applying Exterior Grade Acrylic Primer Of Approved Quality And Brand On Plastered Or Concrete Surface Old Or New Surface To Received Decorative Textured ( Matt Finish ) Or Smooth Finish Acrylic Exterior Emulsion Paint Including Scraping And Preparing The Surface Thoroughly, Complete As Per Manufacturer’S Specification And As Per Direction Of The Eic. ( Two Coats ) A ) G.L. To Top Of 1St Bracing 115 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 116 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 117 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 118 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 119 F ) From Top Of 5Th Bracing To Top Of Heal Beam 120 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 121 H ) From 1 / 3Rd Of Shell Wall To Rest 122 Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window, Ceiling, Floor, Drain Etc. 123 Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothing Surface By Sand Pepering Etc. 124 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryon Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) 125 Painting With Ready Mixed Black Japan Of Approved Make And Brand Including Smoothening Surface.Two Coats. 126 Making Arrangement For Showing The Water Tightness Test Of The Rcc Elevated Reservoir By Filling With Water Upto The Maximum Level Of The Tank To The Full Satisfaction Of Eic ( Arrangements Of Water, Its Carriage And Lifting To The Tank Including Necessary Pipes, Fitting, Pumping Machinery Etc. Are To Be Provided By The Contractor With His Own Cost. ( If Water Is Supplied By The Department Rate Shall Be Reduced As Per Prevailing Departmental Rate ) ) 127 Disinfection And Washing The Tank And Pipe Connections Including Cleaning The Inside Of The Etc. Complete. 128 Hoisting, Erection , Placing Connecting With Pipes And Specials Cidf Pipes, Specials ) Securing With Building Specials Providing Stays, Clamps As Required Including Cost Of Staging Platform For The Work Etc.All Complete In All Respects As Per Drawing And Direction Of Eic.A ) 250Mm.Dia . 129 B ) 150Mm.Dia . 130 C ) 100Mm.Dia . 131 Laying Of Cidf / D.I Pipes With Specials, Valves Etc. In Trenches Including Excavation In All Sorts Of Soil, Moorum, Soft Rock And Refilling The Trenches After Laying & Jointing Of Pipes Etc. All Complete As Per Specification And Direction Of Eic.A ) 250Mm.Dia . 132 B ) 150Mm.Dia . 133 C ) 100Mm.Dia . 134 Fitting, Fixing Duct-Foot Bend Including Construction Of Cement Concrete ( 4:2:1 ) Base With Stone Chips Ofapproved Grade & Quality & Including Excavation Of Earth Etc Complete In All Respect. ( Analysis Rate ) A ) 250Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 135 B ) 150Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 136 C ) 100Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 137 Hoisting, Fitting, Fixing Of Ci Bell Mouth With Puddle Collar In Rcc Work As Per Drawing Specification Complete In All Respect.A ) 250Mm.Dia . 138 B ) 150Mm.Dia . 139 C ) 100Mm.Dia . 140 Construction Of Masonry Drain 300 Mm X 250 Mm Inner Section With 1St Class 250 Mm Th. Brick Work In Cement Mortar ( 1:4 ) Over A Layer Of Single Brick Flat Soling , Sand Filling 100Mm Th. And 100 Mm Th. Weak Cement Concrete ( 6:3:1 ) With Graded Stone Ballast Pakur Variety ( 40Mm Size ) Including Earth Work In Excavation, 15Mm Th. Cement Plaster ( 4:1 ) And Neat Cement Punning All Rounding The Drain Etc. All Complete As Per Approved Design , Drawing And Direction Of The Engineer In-Charge. ( Analysis Rate ) 141 Supply And Delivery Of Different Dia.Cidf Pipe ( Class - B ) I.S: 1538 - 1976 & Specials ( Class - B ) As Per Is: 1538 - 1993 With Latest Amendment Including Loading, Unloading & Stacking Properly For Connection Of Inlet, Outlet, Overflow And Washout Line Of Ohr As Per Departmental Drawing With Specified Dia. Inclusive Of All Incidental Charges If Any All Complete As Per Direction Of The E.I.C. ( Test Certificate From The Manufacturer And Guarantee Certificate Should Be Produced By The Agency ) 142 A ) Supply And Delivery Of Cidf Sluice Valve Pn-10 Of Different Dia Make With Cast Iron Double Flanged Non Rising Spindle Sluice Valve Generally Conforing To I:S 14846-2000 With Latest Amended If Any Having Body Door Dome / Bonnet And Cover Of Cast Iron Gr.- F.G. 200 ( Ref. Is-210 ) Spindle Of Is: 6603 Gr.- 12 / Cr. 13 Non-Magnetic, Nut And Seat Rings Are Gunmetal As Per Is: 1538 Part Iv & Vi Valves Are Suitable For Maximum Working Pressure Of 10Kg / Sq.Cm. ( Seat Test ) And Body Tested To 15Kg / Sq.Cm. ( Test Certificate From The Manufacturer As Well As Inspection Certificate From Third Party Inspection, Agency To Be Arranged By Their Own Cost And To Be Approved By E.I.C. ) N.B. The Above Item Should Be Procured From The Reputed Manufacturer Viz- Kalpana, Jupiter & Upadhaya Or Similar Approved Vender List. [ With Cap ] A ) 250Mm.Dia . 143 B ) 150Mm.Dia . 144 C ) 100Mm.Dia . 145 Construction Of R.C.C. Inlet & Overflow Chamber As Per Drawing Cast With Rcc Wallwithcement Concretenot Leaner Than 1:1.5:3 With Graded 20 Mm Down Pakur Variety Stone Chips And Reforcement Having Wall Thickness 125 Mm And Complete With Plastering 15Mm Th. ( 1:4 ) With Neat Cement Finishing And As Per Direction Of The E.I.C. ( Inner Size = 600 Mm X 600 Mm X 750 Mm ) ( Analysis Rate ) 146 Applyingwate Thinable Non-Toxic Acrylic Polymer Modified Paint Coating Or Equivalent Brand Of Approved Quality 2 ( Two ) Finished Coats Over 2 Coats Of Primer Of Same Brand To The Ceiling Of Roof Dome Including Supplying Supplying Requisite Coating Materials Cleaning Of The Substrant Properly To Make It Free From Dirt, Paint, Oil And Grease Sludge, Blisters, Fungus , Moss, And All Other Undesireble Particles Using Wire Brush , Sand Paper Etc. Including Mending Good All Damages All Complete As Per Direction Of The E.I.C. 147 Supplying Hoisting, Fitting Fixing Approved Type Water Level Indicator With Copper Float, Guide Pulley, Wire Boards Etc. As Per Standard Specification And Direction And Satisfaction Of Eic 148 Site Clearence By Removing All Unserviceablematerials, Debris Etc. All Complete As Per Direction Of E.I.C. 149 Construction Of 3 Nos Pump House And Boundary Wall With Land Development ( Annexure Iv ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.Depth Of Excavation Not Exceeding 1, 500 Mm. 150 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm. As Directed And Consolidating Same By Thorough Saturation With Water Ramming Complete, Including The Cost Of Supply Of Sand. 151 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming Anddressing Bed To Proper Level And Filling Joints With Local Sand. 152 Ordinary Cement Concrete ( 1:2:4 ) With Graded Stone Chips ( 20 Mm Size ) Nominal Size Excluding Shuttering And Reinforcement , If Any In Ground Floor As Per Relevant Is Code. ( A ) Pakur Variety 153 Ordinary Cement Concrete ( Mix 1:1.5:3 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. Pakur Variety 154 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth, In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) ( A ) With Earth Obtained From Excavation Of Foundation. 155 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction.A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . I ) Top Steel / Mild Steel [ I. Sail / Tata / Rinl=> Rs.-53241.00 / M; Ii. Other Than Sail / Tata / Rinl=> Rs.-51991.00 / Mt ] 156 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Foundation And Plinth. 157 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 158 125 Mm Thick Brickwork With 1St Class Bricks In Cement Mortar ( 1:4 ) In Ground Floor 159 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 Mtr Using Approved About Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs , Beams, Columns, Lintels, Curved Or Straight Including Fitting, Fixing & Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) A ) 25 Mm To 30 Mm Thick Wooden Shuttering As Per Decision & Direction Of Engineer-In-Charge. 160 25 Mm Thick Damp Proof Course With Cement Concrete With Stone Chips ( 3:1.5:1 ) ) ( With Gradedstone Aggregates 10 Mm Normal Size ) And Paintingthe Top Surface With A Coat Of Bitumen Using 1.7 Kg Per Sq M Including Heating The Bitumen And Cost And Carriage Of All Materials Complete. 161 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand & Cement Mortar Includgrounding Off Or Chamfering Corners As Directed A Ramming Out Joints Or Roughening Of Concretesurface By Chamfering Etc. Including Threading Noising And Drip Course Where Necessary. ( Ground Floor ) I ) With 1:6 Cement Mortar.20 Mm Thick Plaster 162 I ) With 1:6 Cement Mortar.15 Mm Thick Plaster 163 I ) With 1:4 Cement Mortar.10 Mm Thick Plaster 164 Supplying Fitting, Fixing- Openable Steel Windows As Per Is Sizes With Side Hung Shutters And Horizotal Glazing Bars With / Without Fixed Type Ventilators. [ The Extra Rate Admissible For The Openable Portion Only ] ( P-82, I-33 ) 165 Supplying 1.5Mm Thick M.S. Sheet Fitted And Fixed On One Or Both Faces Of M.S. / W.I. Gate Etc. With Point Welding At Not More Than150mm Apart Complete In All Respect As Per Design Including Cost Of All Labour And Materials 166 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor. ( I ) Grill Weighing Above 10 Kg. / Sq.Mtr And Up To 16 Kg. / Sq. Mtr.Rs.- 8247.00 / Qt, ( Ii ) Grill Weighing Above 16 Kg. / Sq.Mtr And Abovers.-8053.00 / Qt. 167 Applying Decorative Cement Based Paint Of Approved Quality After Preparing The Surface Including Scraping The Same Thoroughly ( Plastered Or Concrete Surface ) As Per ManufactureS Specification In Ground Floor. A ) Two Coats ( On New Cement Plaster Surface ) 168 White Washing Including Cleaning And Smoothening Surfacethoroughly.A ) 3 Coats. 169 B ) Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothening Surfaces By Sand Papering Etc. 170 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryb ) On Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) ( Hi Gloss ) 171 Number Plaque Of Buildings ( Plaque Size Upto 225 Mm X 225Mm ) Made Of Cement Plaster ( 2:1 ) On Face Of Wall Or Plinth , With 50 Mm Size Letters P.H.E. And The Number Of The Structure Formed Thereon ( In Sunk Type ) Including Painting The Letters Complete As Per Direction. ( Cement = 1 Kg / No ) 172 Supplying, Fitting And Fixing PeetS Valve Fullway Gunmetal Standard Pattern Best Quality Of Approved Brandbearing I.S.I. Marking With Fittings . ( Tested To 21 Kg / Sq.Cm. ) ( For Water Lines Only ) .- 15 Mm. Dia. 173 Construction Of Septic Tank Of Different Capacities As Per Approved Drawing With 1St Class Brick Work In Cement Mortar ( 1:4 ) Including Two 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The 100Mm Thick R.C.C ( 1:1.5:3 ) Top Slab With Necessary Fittings, 20Mm Thick Cement Plaster ( 4 : 1 ) With Neat Cement Finish To The Internal Surfaces And 15 Mm Thick Cement Plaster ( 4 : 1 ) To Outside Wall Upto 200 Mm Below G.L Floor Finished With 25 Mm Thick Grey Artificial Stone Over 100 Mm Thick R.C.C ( 1:1.5:3 ) Bottom Slab Including Supplying, Fitting And Fixing All Necessry Specials, Fittings, S.W. Tees, C.I. Foot Rest Etc. Including Excavation Earth In All Sorts Of Soil, Shoring, Bailing Out And Pumping Out Water As Necessary, Ramming, Dressing The Bed And Fefilling The Sides Of The Tanks With Earth, Removing Spoils, Filling Up The Chamber With Clear Water, Removing Foreign Materials From The Chamber And Including Constructing Attached Inspection Pit As Per Approved Drawing And Connecting All Necessary Pipes, Joints Etc. With Internal Plaster Work And Artificial Stone Flooring Is To Be Done With Admixture Of Water Proofing Compound @ 0.5% By Weight Of Cement With All Costs Of Labour And Materials. Note:- ( I ) Finished Level Of Septic Tank Should Be 400 Mm. From Ground Level. ( Ii ) Height Of 50 Mm. Ventilation Pipe &Mosquito Proof Mesh, Should Be Follwed As Per Is:2470, Part I.Payment Will Be Made Separetly On The Basis Of Actual Height Based On Relevant I.S.Code. ( I ) For 10 Usersa ) With Pakur Variety. ( Sail / Tata / Rinl ) 174 Supplying, Fitting & Fixing Orissa Pattern Water Closet In White Glazed Vitreous Chinaware Of Approved Make Supplied , Fitted Fixed In Positioncomplete Excluding P Or S Trap. ( Excluding Cost Of Concrete For Fitting ) I ) 530Mm X 410 Mm 175 Supplying Fitting And Fixing10 Litre Pvc Low-Down Cisternof Conforming To I.S. Specification With Pvc Fitting Complete C.I.Make With Either Side Or Bottom Brackets Including Two Coats Of Painting To Brackets. 176 Supplying Pvc Water Storage Tank Of Approved Quality With Closed Lid ( Black ) -Multilayer. A ) 500 Litre Capacity. 177 Construction Of Circular Soak Well 2.5 Metre Deep In All Types Of Sandy Soils With Dry Brick Work Upto 1.6 Metre From The Bottom Having 150 Mm Intermediate Cement Brick Work ( 1:4 ) Band All Round And Cement Brick Work ( 1:4 ) Upto 0.90 Metre From Top With 20Mm Thick Cement Plastering ( 1:4 ) To Inside Face Upto The Depth Of Cement Brick Work, 15Mm Thick Cement Plaster ( 1:4 ) On Outer Face From Top Of The Well Upto G.L. And 6 Mm Thick Cement Plaster ( 1:4 ) On Top Of The R.C.C. Cover Slab Including Filling Bottom 1.00 Metre Of Inside Of The Well With Brick Metal ( 50 Mm To 63 Mm Size ) Including R.C.C. Cover Slab Of 100 Mm Thick With Cement Conc ( 1:1.5:3 ) With Stone Chips With Necessary Reinforcement And Shuttering Including One 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The Cover Slab With Necessary Fittings, Making Nacessary Arrangements For Pipe Connections, Excavation Of Well Including Shoring, Dewatering And Removing The Exess Earth From The Premises As Per Direction Complete In All Respect With All Costs Of Labour And Materials. With 250 Mm Thick Dry Brick Work And 250 Mm Thick Cement Brick Work ( 1:6 ) And 1.00M Inside Dia. ( Sail / Tata / Rinl ) 178 Supplying, Fitting & Fixing Upvc Pipes A-Type And Fittings Conforming To Is:13592-1992 With All Necessary Clamps Nails, Including Making Holes In Walls, Floor Etc. Cutting Trenches In Any Soil Through Masonry Concrete Structures Et. If Necessary And Mending Good Damages Including Joining With Jointing Materials ( Spun Yarn, Valamoid / Bitumen / M-Seal Etc ) Complete. ( A ) 75Mm. Dia. 179 Supplying, Fitting And Fixing Fan Hook For Ceiling With1 Metre Long16mm Dia Rod Complete Including Mending Damages .Payment For Damage And Repair To Be Made Separately. 180 Wash Basin White Vitreous China Of Approved Make ( Without Fittings ) Supplied , Fitted And Fixed In Position On 75Mm X 75Mm X 75Mm Wood Blocks And C.I. Brackets Including Two Coats Of Painting Of C.I. Brackets. ( A ) 450 Mm X 300 Mm Size. 181 Supplying, Fitting And Fixing Approved Brand P.V.C. Connector White Flexible, With Both Ends Coupling With Heavy Brass C.P. Nut, 15 Mm Dia. ( A ) 900 Mm Long. 182 Cutting Holes And Subsequent Mending Good Damages. 183 Supplying , Fitting And Fixing 30 Mm. Thick Both Side Prelaminated Factory Made Solid Panel Pvc Door Shutter Consisting Of Outer Frame Made Out Of Ms Tubes Of 19 Gauge Thickness And Size 19 Mm. X 19 Mm. For Styles, Top And Bottom Rails, Ms Frame Shalll Have Cost Of Steelprimers Of Approved Make And Manufacture, M.S Frame Cover With 5 Mm.Thick Head Moulded Pvc C Channel Of Size 30 Mm. Thick 70Mm. Width Out Of Which 50 Mm. Shall Beflat And 20Mm. Shall Be Tapered In 45 Degree Angle Of Either Side Forming Styles, And 5Mm Thick 95 Mm. Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Tapered In 45 Degree On The Inner Side Toform Top & Bottom Rail And 115Mm.Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Shall Be Tapered On Both Sides To Form Lock Rail. Top Bottom And Lock Rails Shall Be Provided Either Side Of The Panel With 10Mm. ( 5Mm. X 2 Mm. ) Thick , 20 Mm. Wide Cross Pvc Sheet As Gap Insert For Top Rail And Botttom Rail Sheet To Be Fitted In The M.S Frame Weled / Sealed Tothe Styles &Rails With 7 Mm. ( 5Mm. + 2 Mm. ) Thick X 15 Mm. Wide Pvc Sheet Beading On Inner Side And Joint Together With Solvent Cement Adhesive . An Additional 5 Mm. Thick Pvc Strip Of 20 Mm. Which Is To Be Stuck On The Interior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Com Excluding All Necessary Hardwire As Per Direction Of The E.I.C In Ground Floor. 184 Supplying Fitting Approved Type Ventilator In Position After Cutting Holes In Walls, Setting In Cement Mortar, Mending Damages To Wall And Plaster And Two Coats Of Paint Of Approved Brand Sand Shade .Payment Of Mending Two Damages Of Wall & Plaster And Painting To Be Made Separately.R.C.C. Ventilator Of 20 Mm Thick - Upto 0.10 Sq.M. Area 185 Constructing Inspection Pit Of Inside Measurement 600 Mm X 600 Mm X Upto 600 Mm ( Depth ) With 250 Mm Thick 1St Classbrick Work In Cement Mortar ( 1:4 ) On All Sides , Bottom Of The Pit Consisting Of 100 Mm Thick Cement Concrete ( 1:3:6 ) With Stone Chips Over A Layer Of Jhama Brick Flat Soling, 15 Mm Thick ( 1:4 ) Cement Plaster To Inside Walls And Outside Walls Upto Gl And 20 Mm Thick ( 1:4 ) Plaster To Bottom Of The Pit, Providing Necessary Invert With Cement Concrete ( 1:3:6 ) With Stone Chips As Per Direction, Neat Cement Finishing To Entire Internal Surfaces, Top Of The Pit Covered With 100 Mm Thick Rcc Slab ( 1:1.5:3 ) With Stone Chips And Necessary Reinforcements Upto 1% And Shuttering Including 6 Mm Thick Cement Plaster ( 1:4 ) In All External Surfaces Of The Slab And One 560 Mm Dia Rcc Manhole Cover Of Approved Make Supplied, Fitted And Fixed In The Slab With Necessary Fittings, Necessary Earth Work In Excavation In All Sorts Of Soil, Filling Sides Of The Pit With Earth And Removing Spoils After Work Complete In All Respects With All Costs Of Labour And Materials. -With Pakur Variety. 186 Supplying , Fitting And Fixing Cast Iron P Or S Trap Conforming To I.S. 3989 / 1970 And 1729 / 1964 Including Lead Caulked Joints And Painting Two Coats To The Exposed Surface. ( Painting To Be Paid Seperately ) .- S Trap - 100 Mm. 187 Supplying, Fitting And Fixing Alloy Iron With Brass Spindle Bib Cock / Stop Cock Of Approved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq.Cm. - 15 Mm. Dia. 188 Supplying, Fitting And Fixing Approved Patent Vent Cowl I.C.I. Conforming To I.S.S And Painting Two Coats To The Exposed Surface With Approved Paint Complete. ( Payment Of Painting Will However Be Paid Seperately ) .- 100 Mm Dia. 189 Supplying, Fitting And Fixing Pillar Cock Of Approved Make. A ) I ) Cp Pillar Cock-15 Mm ( Equivalent To Code No-507 & Model - Tropical / Sumthing Special Of Essco Or Similar Brand ) . 190 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. A ) With Carried Earth Arranged By The Contractor Within A Radius Of 3 Km. Including Cost Of Carried Earth. 191 Laying For Rising Main & Distribuition System With Fhtc ( Annexure V ) Carrying Ci / Di Pipes With Specials And Valves And Lowering Placing In Position And Laying Carefully Inside The Trenches In Proper Alignment And Gradient Etc.Including Earth Work Inexcavation Of Adequate Width As Per Specification Having Min. Clear Cover From Top Of Pipe Is 1.10Mtr. Below Existing Ground Level In Any Kind Of Soil Including Mixed With Boulder, Road Sub-Grade And Its Flank, But Excluding Moorum And Laterite And Stone Etc.Without Damaging The Exisiting Telephone / Electric Cableetc. ( Incaseof Damaged If Any Type Of Cable Line During Excecution , Necessary Damaged Charges As Applicable By The Respective Authority Will Beborne By The Agency In His Own Cost ) Preparing The Bottom Surface For Continuous Bedding Of Pipe Line And Laying Pipes, Fitting, Fixing Specials And Valves With Bailing Out Water If Any Including Carriage Of Pipes, Specials And Valves From Local Deptt.Store Within 8Km And Back Filling The Trenches With Excavated Earth In Layers To Original Condition As Per Specification And Direction Of Eic. The Surplus Materials After Execution Of Work Are To Be Return To The Deptt. Store.N.B: I ) Any Deviation From Required Clear Cover Of 1.10Mtr., Due To Site Adverse Condition, Prior Permission Is To Be Obtained From The Eic In Exceptional Situation And Payment Will Be Made On Prorate Basis Over The Rate Of Entire Item Ii ) No Payment Will Be Made Without Hydraulic Test Of The Pipe Line Either Part Or Full Iii ) Thepipes, Specials And Valves , Rubber Gasket Will Be Supplied Deptt. Free Of Cost.A ) 150Mm Dia. 192 B ) 200Mm Dia. 193 C ) 250Mm Dia 194 Making Rubber Gasket Joint To Ci / Di Pipes Maintaining Proper Alignment Level Etc. By Mechanical Arrangement With Or Without Using Mobile Cranes Where Necessary And With Help Of All Other Equipments Tools And Tackles Etc. As Required Providing Lubricants Of Approved Quality And Direction Of Eic. ( Rubber Gasket Will Be Supplied Deptt. Free Of Cost ) B ) 150Mm Dia. 195 C ) 200Mm Dia. 196 D ) 250Mm Dia 197 Making Flange Joint To Di / Ci Pipes, Specials And Valves Where Necessary With Supply Of Required Rubber Insertion And Nut Bolts, Washers Etc. Of Approved Quality And Type All Complete As Per Specification And Direction Of Eic ( Nut And Bolts Shall Be Of Tata / Gkw Rate ) .A ) 250Mm Dia 198 B ) 200Mm Dia. 199 C ) 150Mm Dia. 200 E ) 100Mm.Dia . 201 Cutting Di Pipe ( All Class & Type ) To Required Length With Cutting Device Etc. And Grinding The Cutting Portion With File As Per Direction And Satisfaction Of Eic.B ) 150Mm.Dia.To 200Mm.Dia Pipe 202 C ) 250Mm.Dia.To 350 Mm.Dia Pipe 203 Chamfering The Spigot End Of All Type / Class Of Di Pipe For Proper Using Of Push Joint By Means Of Grinder Set At Site For Proper Joint Etc. All Complete As Per Direction Of Eic.B ) 150Mm Dia. 204 C ) 200Mm Dia. 205 D ) 250Mm Dia 206 Filling The Pipe Line With Water, Testing Hydraulically As Per I.S 3114-1965 ( Article-6 ) In Section Of A Length Not Exceeding 500Mtr. For Head Of Pressure As Per Specification Including Supplying Installing And Fixing All Equipments Such As Diesel Pump Set, Blank Flange, Pressure Gauge, Valve, Pressure Pump And All Other Tools And Plants Including Drilling Topping And Plugging Of Necessary Holes To Pipes, Blocking Ends Providing Temporary Thrust Block And Subsequent Blocking Of Holes And Other Jointing Materials And Dismantling And Removal Of The Same Including Disposal Of Water Etc. All Complete As Per Specification And Direction Of Eic. The Rate Is Inclusive Of Cost Of Requisite Water To Be Arranged By The Contractor ( Recovery Rate Of Water @ Rs.10.00 / M3, If Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.A ) 150Mm Dia. 207 B ) 200Mm Dia. 208 C ) 250Mm Dia 209 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 210 B ) 63Mm ( Od ) 211 C ) 75Mm ( Od ) 212 D ) 90Mm ( Od ) 213 E ) 110Mm ( Od ) 214 F ) 125Mm ( Od ) 215 G ) 140Mm ( Od ) 216 H ) 160Mm ( Od ) 217 I ) 180Mm ( Od ) 218 J ) 200Mm ( Od ) 219 K ) 225Mm ( Od ) 220 Cleaning Thoroughly The Inner Surface Of Pipe Line Including Specials And Valves By Flushing With Water And Subsequently Disinfection Of The Same Pipe Line By Flushing Again With Water Containing Bleaching Powder Resulting In Residual Chlorine Not Less Than 15Mg / Ltrs. After 24Hrs. Of Such Filling Including Laboratory Testing Of Water Samples Obtain From The Disinfested Pipe Line And Disposal Of Water From The Pipe Line After Completion Of The Work. The Rates Including Of Cost Of Requisite Water To Be Arranged By The Contractor ) ( The Rate Of Water @Rs. 10 / M3 May Be Recovered, If The Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.B ) 150Mm Dia. 221 C ) 200Mm Dia. 222 D ) 250Mm Dia. 223 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 224 B ) 63Mm ( Od ) 225 C ) 75Mm ( Od ) 226 D ) 90Mm ( Od ) 227 E ) 110Mm ( Od ) 228 F ) 125Mm ( Od ) 229 G ) 140Mm ( Od ) 230 H ) 160Mm ( Od ) 231 I ) 180Mm ( Od ) 232 J ) 200Mm ( Od ) 233 K ) 225Mm ( Od ) 234 Submission Of Complete Detailed Drawing Of Distribution System, Rising Main Etc. After Execution Of Work Showing Position Of Different Types Of Valves, Fittings / Specials Sluice Valve Chamber With Location, Node To Node Wise In The Sanctioned Drawing As Completion Drawing Of The Water Supply Scheme As Per Direction And Satisfaction Of Eic. The List Of Dia Wise Fitting / Specials, Different Pipes ;Of Valve Used In The Rising Main Should Be Shown In The Completion Drawing ( Not Separate ) With Verified By Sae & Ae In-Charge Of The Scheme. The Above Drawing Will Be Submitted In 5 Copies. 235 Bituminous Pucca Road ( Approx. 450Mm Depth ) Cutting By Using Gaiti, Chisel, Hammer Etc. And Picking Uip The Withdrawing Excavated Materials And Remove The Same Within Distance Of 30Mtr. At Least All Complete For Fixing / Crossing All Dia Of Pipe Line As Per Direction Of Eic 236 Dismantling All Type Of Plain Cement Concrete Works, Stacking Serviceable Materials Of Site And Removing Rubbish As Directed Within A Lead Of 75Mtr. For Laying All Dia Pipe Line In Ground Floor, Upto 150Mm Thick.A ) Upto 150Mm Thick 237 B ) Above 150Mm Thick 238 Construction Of Different Dia Sluice Valve / Air Valve / Washout Chamber In Different Sizes For Village Road Where Light Traffic Run And For Main Road Where Heavy Traffic Run As Deptt.Approved Drawing With 25Cm Thick Brick Work ( 1:6 ) Over Cement Concrete ( 4:2:1 ) Over A Single B / F Soling Over150mm.Thick Sand Filling In Foundation Including Earth Work In Excavation And Disposal Of Excess Earth From Work Site With Rcc ( 1:1.5:3 ) Cover Slab 100Mm / 150Mm Thick Slab On Top Of Chamber With 1% Reinforcement Inrcc Cover Slab With Necessary Opening For Operation Of Valve All Complete Including Cost Of Labour & Materials As Per Departmental Dwg. [ Reinforcement Type:- Other Manufactuerers Not Specified ] I ) 80 Mm To 150 Mm Dia Pipe 239 Ii ) 200 Mm Dia Pipe 240 Iii ) 250 Mm Dia To 350Mm Dia Pipe 241 Making Holes In Two Sides Of Wall Of Culvert / Drain Or Any Other Structuresin Any Places For Laying Any Dia Pipe Line Within Structures Intwo Sides Of Wall Of Culvert / Drain / Any Structure At Any Places And Mending Good Damages All Complete As Per Direction Of Eic. 242 A ) Construction Of Rcc Street Stand Post ( 700Mm Height ) Of Rcc ( 1:1.5:3 ) Footing Over 75Mm Thick 4:2:1 P.C.C Over A Single B / F Soling With 1% Reinforcement, Connected With Saddlepiece & 15Mm Dia Brass Ferrule With Supplying Fitting, Fixing 15Mm Dia G.I. Nipple, G.I.Socket, G.I. 200Mm X 150Mm Reducing Elbow And 20Mm Dia Gi ( M ) Tata Pipe Of ( Avg. ) 2.6Mtr. Long And One 15Mm Dia Alloy Iron With Brass Spindle Bib Cock With Socket And 20Mm G.I. Elbow 2Nos. With 15Mm Gi ( M ) Tata Pipe Of 0.225Mtr. For Connection Of Stand Post To Distribution Line As Per Deptt. Design And Drawing As Per Direction Of Eic Along With Construction Of Platform Of Size Cc Platform ( 1:2:4 ) Over A Single B / F Soling Below G.L Over 150Mm.Thick Sand Filling, Neat Cement Finish Over Platform And Inner Side Of Band And 15Mm Thick Cement Plaster ( 4:1 ) On Top Of Platform Band And Outside Upto G.L. As Per Deptt. Drawing And As Per Direction Of Eic 243 Supplying Hdpe ( Materials Grade Pe-80 ) Pipes Conforming To Is 4984-1995 With Latest Revision & Amendments If Any With Necessary Hdpe Specials ( Excluding Cost Of Cidf Valves ) Including Labour Charges For Earth Work In Excavation In Any Kind Of Soil Including Mixed Soil With Boulder, Road Sub-Grade And Aits Flank But Excluding Moorum Laterite Or Sand Stone / Hard Rock Cutting With Chisel Required Including Cutting Road Flank / Brick Pavement Etc. Without Damaging The Exisiting Telephone / Electrical Cable Line Etc. ( In Case Of Damage Of Any Type Of Cable Line By The Agency At The Time Of Execution Necessary Damage Charge As Applicable By The Respective Authority Will Have To Be Brone By The Agency At His Own Cost ) Upto The Depth ( Av. ) So As To Maintain 1.10M.Earth Cushion From Top Of The Pipe Upto G.L. Including Loading Unloading Carrying Lowering Laying Fitting Fixing Carefully Pipes, Valves And Specials With The All Types Of Jointing Materials In Trenches Maintaining Proper Levels And Alignment Jointing The Pipes And Specials By Butt Welding / Adopting Suitable Method ( But Weld Jointing With Help Ofhydraulic Tack And Trimming Machines, Hitter Etc. For Reaching At Necessary Melting Point Of Hdpe Pipe So That Joint Can Be Monolithic ) So As To Facilitate The Maintenance Of Pipe Line Locally As Per Conventional Method In Future. ( A ) Pressure Rating : Pn 6Ii ) Laying Of Pipe Line Including Cost Of Pipe & Fittings / Specials Butexcluding Cost Of Valvesa ) 50Mm ( Od ) 244 B ) 63Mm ( Od ) 245 C ) 75Mm ( Od ) 246 D ) 90Mm ( Od ) 247 E ) 110Mm ( Od ) 248 F ) 125Mm ( Od ) 249 G ) 140Mm ( Od ) 250 H ) 160Mm ( Od ) 251 I ) 180Mm ( Od ) 252 J ) 200Mm ( Od ) 253 K ) 225Mm ( Od ) 254 Providing Fhtc From The Existing Cl / Dl / Upvc / Hdpe / Gl / Ac Distribution Pipeline By Installing 10 Mm Nb Gun-Metal Ferrule Conforming To Is 2692:1989 With Latest Amendments On The Said Pipeline With Supply, Fitting & Fixing Of All Other Accessories Like Saddle Piece Of Required Size To Fit The Existing Distribution Pipeline, Specials, Nut & Bolts, Rubber Sheet, Washers Etc And Supply & Laying Of 15Mm Nb Pvc ( Schedule 80 ) / 20Mm Od Hdpe ( Peioo, Pn16 ) Pipe ( Average 15M Length ) With All Necessary Specials 1.0 Metre Below The Ground Connecting The Ferrule Including Cutting Trenches In All Sorts Of Soil And Filling Up Trenches As Per Direction Of The Engineer-In-Charge And Upto A Point Just Inside The Premises Of The Household Or As Directed By Eic. Supply And Installation Of A 15Mm Dia. Alloy Iron Bib Cock ( Tested To 21 Kg / Cm2 ) Above 1.0 Mtr. From Ground, An Alloy Stop Cock Of 15 Mm Dia. With Brass Spindle ( Tested To 21 Kg / Cm2 ) To Be Fitted In A Position As Directed By E.I.C. G.L Pipe Of Tata Make ( Medium Duly ) Of 2 Metre Length With All Necessary Specials To Continue From The End Of The Hdpe / Pvc Pipe And Upto 1.0 M Above Ground Within The Premises Of Household.Note : 1. Pvc Pipe Shall Of Schedule 80 ( Medium Duty ) Conforming To Astmd-1785 And Threaded To Match With Gi Pipe As Per Is: 1239 ( Part-I ) .2. Rate Is Exclusive Of Supply And Delivery Of 10Mm Nb Gun Metal Ferrule.3. Payment Of Supply And Laying Of 15Mm Dia Nb Pvc ( Schedule 80 ) Or 20Mm Od Hdpe ( Pe 100, Pn 16 ) Pipe With All Necessary Specials 1.0M Below The Ground Will Be Made On Actual Measurement Basis. The Rate Of This Item Is Rs. 117 / -Per Metre.A ) Upto 10M Length 255 B ) Above 10M Upto 20M Length 256 Colection Of Household Details As Per Prescribed Formatthrough Mobile App / Hard Copies Including Geo Referance As Diected By E.I.C And Submission Of The Same To The P.H.E Dte.In Soft Copies. 257 Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement, If Any, In Ground Floor As Per Relevant Is Codes.A ) Pakur Variety 258 Cost For Boring Any Type Of Soil By Augor Boring ( Horizontal ) With Water Jet System Including Hire Charges Of Machine, Tools & Plants, All Complete With All Labour And Supply Of Water Etc. As Per Specification And Direction Of Eic.I ) 80Mm To 100Mm Dia. 259 Ii ) 125 Mm To 200 Mm Dia 260 Supplying, Fitting And Fixing In Position G.I. Pipes Of Tata Make For Underground Works With All Necessary Accessories, Specials Viz.Socket, Bend, Tee, Union, Cross, Elbow, Nipple, Short Piece Etc.Including Cost Of All Materials, Jointing Materials , Cutting Pipes, Making Threads, Cutting Trenches Upto 1.5 Metre Below Surface In All Sorts Of Soil And Refilling The Same As Directed With Two Coats Of Painting On G.I. Pipes And Specials With Bituminous Paint Complete In All Respect. ( Payment Will Be Made On The Centre Line Measurement Of The Total Pipe Line Including All Specials No Separate Payment Will Be Made For Accessories, Specials.Payment For Painting Will Be Made Seperately ) ( S & P Schedule, Page-2 ) H ) ( Ii ) 80 Mm Dia. Medium Quality. 261 Supplying, Spreading And Consolidating Stone Dust To A Depth Of 100 Mm And Above At Desired Density And C.B.R. As Per Specification With Power Roller To Proper Gradient And Camber Including Watering As Necessary, And Lighting, Guarding, Barricading And Making Adequate Earthen Bundh Where Necessary To Protect The Edges And Curing With Water For 2 To 3 Days, Mending Cracks And Depressions By Rolling Where Necessary Including All Incidental Charges Of Roller, Cost Of Fuel & Lubricants Complete As Per Specification. ( Ref ; Pwd Sor 17 , Page No 242 , Item No 4.06 ) 262 Carriage Of Different Type Of Departmental Pipes From Divisional / Sub-Divisional Store To The Work Site By Truck Including Loading, Unloading, Stacking Etc. Including Cost Of Fuel, Lubricant And Also Cost Of Driver, Helper Etc. And All Other Taxes And Charges As Applicable As Per Direction Of Eicf ) Above 40 Km Upto 50 Km 263 G ) Above 50 Km ( Extra Cost Per Km ) Extra 50 Km ( 4 Nos Truck X 50 Km Each = 200 Km )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
40.
Defence #10694380 Price Bid
Tender For Construction Of 03 Nos Bore Well At Nsg Campus Manesar Gurgaon ( Haryana ) .; 1 Earth Work 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 3 All Kinds Of Soil. 4 Cement Concrete ( Cast In Situ ) 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 6 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 7 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For : 8 Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses Fillets, Kerbs And Steps Etc. 9 Reinforced Cement Concrete 10 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 11 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natu- Ral Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 12 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . 13 Providing And Fixing Tie Bolt, Spring Coil And Plastic Cone In Wall Shuttering Complete As Per The Direction Of Engineer-In-Charge. 14 20 Mm Dia.& 225 Mm Length 15 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. 16 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 17 Flooring 18 52 Mm Thick Cement Concrete Flooring With Concrete Hardener Topping, Under Layer 40 Mm Thick Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) And Top Layer 12 Mm Thick Cement Hardener Consisting Of Mix 1:2 ( 1 Cement Hardener Mix : 2 Graded Stone Aggregate 6 Mm Nominal Size ) By Volume, Hardening Compound Mixed @ 2 Litre Per 50 Kg Of Cement Or As Per ManufacturerS Specifications. This Includes Cost Of Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 19 Finishing 20 6 Mm Cement Plaster Of Mix : 21 1:3 ( 1 Cement : 3 Fine Sand ) 22 Water Supply 23 Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. External Work 24 65 Mm Dia Nominal Bore 25 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 26 25 Mm Nominal Bore 27 Painting G.I. Pipes And Fittings With Two Coats Of Anti-Corrosive Bitumastic Paint Of Approved Quality : 28 65 Mm Diameter Pipe 29 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) : 30 65 Mm Nominal Bore 31 Providing Push-On-Joints To Centrifugally ( Spun ) Cast Iron Pipes Or Ductile Iron Pipes Including Testing Of Joints And The Cost Of Rubber Gasket : 32 100 Mm Dia Pipes 33 Drainage 34 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20x10 Cm Cement Concrete Blocks 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) As Per Standard Design : 35 With 20X20 Mm Square Bar 36 Supplying And Fixing C.I. Cover Without Frame For Manholes : 37 455X610 Mm Rectangular C.I. Cover ( Light Duty ) The Weight Of The Cover To Be Not Less Than 23 Kg 38 Rain Water Harvesting & Tubewells 39 Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, By Suitable Method Prescribed In Is: 2800 ( Part I ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90 Metre Depth Below Ground Level. 40 All Types Of Soil 41 300 Mm Dia 42 Rocky Strata Including Boulders 43 300 Mm Dia 44 Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, By Suitable Method Prescribed In Is: 2800 ( Part I ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer -In-Charge, Beyond 90 Metre & Upto 150 Metre Depth Below Ground Level. 45 Rocky Strata Including Boulders 46 300 Mm Dia 47 Gravel Packing In Tubewell Construction In Accordance With Is: 4097, Including Providing Gravel Fine / Medium / Coarse, In Required Grading & Sizes As Per Actual Requirement, All Complete As Per Direction Of Engineer-In-Charge. 48 Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Erw ( Electric Resistance Welded ) Fe 410 Mild Steel Screwed And Socketed / Plain Ended Casing Pipes Of Required Dia, Conforming To Is: 4270, Of Reputed & Approved Make, Including Painted With Outside Surface With Two Coats Of Anticorrosive Paint Of Approved Brand And Manufacture, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Direction Of Engineer-In-Charge. 49 200 Mm Nominal Size Dia Having Minimum Wall Thickness 5.40 Mm 50 Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Erw ( Electric Resistance Welded ) Fe 410 Plain Slotted ( Having Slot Of Size 1.6 / 3.2 Mm ) Mild Steel Threaded And Socketed / Plain Bevel Ended Pipe ( Type A ) Of Required Dia, Conforming To Is: 8110, Of Reputed And Approved Make, Having Wall Thickness Not Less Than 5.40 Mm, Including Painted With Outside Surface With Two Coats Of Anticorrosive Bitumestic Paint Of Approved Brand And Manufacture, Including Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Direction Of Engineer -In-Charge. 51 150 Mm Nominal Size Dia 52 200 Mm Nominal Size Dia 53 Development Of Tube Well In Accordance With Is : 2800 ( Part I ) And Is: 11189, To Establish Maximum Rate Of Usable Water Yield Without Sand Content ( Beyond Permissible Limit ) , With Required Capacity Air Compressor, Running The Compressor For Required Time Till Well Is Fully Developed, Measuring Yield Of Well By V Notch Method Or Any Other Approved Method, Measuring Static Level & Draw Down Etc. By Step Draw Down Method, Collecting Water Samples & Getting Tested In Approved Laboratory, I / C Disinfection Of Tubewell, All Complete, Including Hire & Labour Charges Of Air Compressor, Tools & Accessories Etc., All As Per Requirement And Direction Of Engineer-In-Charge. 54 Providing And Fixing M.S. Clamp Of Required Dia To The Top Of Casing / Housing Pipe Of Tubewell As Per Is: 2800 ( Part I ) , Including Necessary Bolts & Nuts Of Required Size Complete. 55 200 Mm Clamp 56 Providing And Fixing Bail Plug / Bottom Plug Of Required Dia To The Bottom Of Pipe Assembly Of Tubewell As Per Is:2800 ( Part I ) . 57 150 Mm Dia 58 Mr Items 59 Charges For Conducting Geophysical Surface Resistivity Investigation For Tubewell Site Selection To Find Out Thickness Of Alluvial, Protential Zones, Water Quality Variation With Depth & Type Of Rig To Be Deployed. 60 Electrical 61 Supplying, Installation, Testing And Commissioning Of Multi Stage Submersible Pump Set, In Bore Well Complete Withcoupled Totally Enclosed Electric Motor Suitable For 415 Volt, 50 Hz, 3 Phase A. C. Supplyincluding Water Proof Jointing Of Cables. ( Excluding Lowering Charges, Lowering Charges Of Submersible Pumpset Included In The Item Lowering Of Column Pipe ) ( Horse Power Of The Motor , Stage , Lpm & Head Of The Submersible Pump Will Be Decided By Engg In Charge On Basis Of Yield Report Submitted By The Contractor ) 62 Providing And Loweringgi Pipes Class B Marked With Is: 1239 In 6 M Length, Including Threading And Welding With Flanges ( Heavy Duty ) On Both Sides, Jointing With Nuts And Bolts, Rubber Gaskets, Into Tube Wells And Testing Commissioing Etc. Complete In All Respects To The Satisfaction Of Engineer-In- Charge. ( Make :Isi Marked B Class Jindal Hisar / Tata / Prakash Surya / Swastik / Zenith Maked G.I. Pipe ) 63 50Mm Dia 64 65Mm Dia 65 Supplying And Laying Of One Numberflat Copper Conductor Submersible Cable Of Following Size Pvc Insulated And Pvc Sheathed Flat Copper Submersible Cable Of 1.1 Kv Grade Along Thelength Of Coloum / Delivery Pipe / In The Existing Masonry Open Duct / Along Wall Surface / Cable Tray / Loose For Connections / In Existing Pvc Casing / Capping Etc. As Required. ( Isi Marked Make Havells / Polycab / Finolex / Rr Kabel ) 66 3 X 4.0 Sqmm 67 Supplying & Fixing Nylon Rope 16Mm Dia Complete With Shackles For Fixing Of Pump Set During The Lowering Of Pumpset To Avoid Slippage Complete As Reqd . 68 Providing And Fixing Three Phasesubmersible Pump Controllers With Single Phase Preventer Submersible Motormodel Mug15fasd Make L&T Suitable Relay Rangeor Equivalent In Havells & Siemens In Existing Cubicle Panel Board Making Connections, Etc. As Required. ( Relay Range & Horse Power Of The Starterwill Be Decided By Engg In Charge On Basis Of Submersible Motor Capacity ) 69 Supply, Installation, Testing And Commissioning Of Outdoor Type Totally Enclosed, Dust And Vermin Proof, Pedestal Mounted Inspection Box / Junction Box Of A Suitable Size But Not Less Than 600 Mm Wide X 450 Mm Height X 450 Mm ( Deep ) Fabricated From 2 Mm Thick Crca Sheet Steel Having Front And Back Openable Doors With Locking Arrangement On Both Sides, Tapered Top ( Roof ) , Including Detachable Cable Gland Plate Made Of 3 Mm Thick Crca Sheet, Including Pre-Paint Treatment, Phosphating And Powder Coating By Approved Siemens Grey Paint, Earthing Stud, Danger Notice Plate Fixed, Complete As Required. The Feeder Pillar Should Be Complete With A Mounting Frame Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron With 900 Mm Long Legs. The 4 Legs Of The Feeder Pillar Shall Be Erected On A Suitable Size 1:3:6 Cement Concrete ( 1:3:6 Cement; 3 Sand; 6 Graded Stones Of 20 Mm Size ) Pedestal Having 900Mm Of Depth ( 600Mm Below Ground & 300Mm Above Ground ) . 70 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 71 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 72 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 73 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 74 90 Mm Dia ( Od-90 Mm & Id-76 Mm Nominal ) 75 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) In The Existing Trench Complete As Required. 76 90 Mm Dia ( Od-90 Mm & Id-76 Mm Nominal ) 77 The Road Crossings Of Power Cablethrough Trenchless Boring.Trenchless Boring Using Manual / Machine Moling Techniqueat 0.75 Metre Below The Ground Level For Following Size Pipes, Including Survey Of Under Ground Utilities, Excavation Of Pits, Moling With The Hole Size Not Exceeding 20% Of The Pipe Dia, Backfilling, Compaction And Restoration Of The Pits To Original Condition Etc. As Required.The Rates For Moling, As Indicated Are Inclusive Of Excavation Of Pits, Backfilling, Compaction Andrestoration Of The Pits To Original Condition. Any Damages Occurred To Other Utilities During The Moling Operation Shall Be Immediately Notified And Rectified By The Contractor Without Any Cost Implication To The Department. The Length Of The Hole ( Excluding The Sizes Of The Pits On Both Ends ) Shall Be Considered For The Measurement Of Moling Length. However, Intermediate Pits Will Consider In The Moling Length.I ) Upto 150 Mm Dia Dwc Hdpe / G.I. / Pvc 78 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 79 3.5 X 35 Sq. Mm 80 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. 81 3.5 X 35 Sq. Mm 82 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size In The Existing Masonry Open Duct / Along Pole / Loose For Connections Etc As Required. 83 3.5 X 35 Sq. Mm 84 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required 85 3.5 X 35 Sq. Mm 86 Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cm X 50 Cm At The Top With A Thickness Of 10Cm Including Inscription Duly Engraved As Required. 87 Add 1.0633 Multiplying Factor For Gst On Dsr
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
41.
Educational and Research Institute #10613954 Price Bid
Corrigendum - Providing Power Supply To Newly Purchased Equipment At Production Process Laboratory In Mechanical Dept . - 2 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 3 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 4 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 5 / 6 A Switch 6 15 / 16 A Switch 7 3 Pin 5 / 6 A Socket Outlet 8 6 Pin 15 / 16 A Socket Outlet 9 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 10 6 Module ( 200 Mmx75 Mm ) 11 Dlp Plastictrunking Wiring ( Make: Legrand / Mk ) T T T T T T T R N 12 Laour Charges For Fixing Of Dlp Pastic Trunking 105X50mm With Supply Of Necessary Accessories Of Joints For Cover 85Mm Width-1No, Basejoint-25Nos, Clips-15Nos, Separation Partition-1No, Endcap-2No, Internal Angles-Adjustable From 80 Degr - 120 Deg - 1No, Vdi Accessories For Internal Angles-1No, Vdi Accessories For External Angles -1No, Flat Angles -1No, Vdi Accessories For Flat Angles-1No, Flat Junctions-1No, Flat Junctions For Specific Size-Tap Off To An 80Mm Wide Branch -1No, Vdi Accessories For Juctions -1No, Wall Crossing -1No, Capacity Change -1No, Capacity Change-1No, Partition Junction -1No, Cable Ties Base -1No. ( 105Mm Base And 85Mm Flexible Cover Is Nitt Scope ) 13 Mccb, Mcb & Dbs 14 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 15 200 A, 36Ka, Fpmccb 16 250 A, 36Ka, Fpmccb 17 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 18 Triple Pole 19 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 20 Supplying And Fixing Of Following Rating, Three / Four Pole, 415 Volts, Isolator / Mcb In The Existing Mcb / Db Complete With Connections, Testing And Commissioning Erc.As Required. 21 Triple Pole 40-63A Mcb 22 Triple Pole 100A Mcb 23 Supplying And Fixing Following Ways Surface / Recess Mounting, Vertical Type, 415 Volts, Tpn Mccb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 160-250 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs, With Provision Of 160-250 Amps Mccb As Incomer, Interconnection Between Incomer Mccb And Bus Bars ( But Without Mcbs / Mccb ) As Required . ( Note : Vertical Type Mccb Tpdb Is Normally Used Where 3 Phase Outlets Up To 100A ) ( Make: Abb / Legrand / Siemens ) 24 8 Way, 250A, Double Door 25 12 Way, 250A, Double Door 26 Earthing 27 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 28 Supplying And Fixing Cosmos Earthig Electrode Systems. T T T T T T T R N T T T T T T T R N 29 Cosmos Roma 40Mm Dia 2 Mtrs Length With Moisture Enhancer 25 Kg. T T T R N 30 Mv Cable Laying 31 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. 32 Upto 35 Sq. Mm 33 Above 95 Sq. Mm And Upto 185 Sq. Mm 34 Mv Cable Jointing & End Termination 35 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 36 3½ X 120 Sq. Mm ( 45 Mm ) 37 3½ X 185 Sq. Mm ( 57Mm ) 38 3½ X 300 Sq. Mm ( 70 Mm ) 39 4 X 16 Sq. Mm ( 28Mm ) 40 4 X 50 Sq. Mm ( 35 Mm ) 41 Misc. Civil Items 42 Foundation Works / Earth Works 43 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) : 10 Graded Stone Aggregate 40 Mm Nominal Size ) . 44 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. For All Kinds Of Soil 45 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: 46 Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 47 Finishing 48 12 Mm Cement Plaster Of Mix : 1:6 ( 1 Cement: 6 Fine Sand ) 49 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. 50 Nominal Concrete 1:4:8 Or Leaner Mix ( I / C Equivalent Design Mix ) 51 Fabrication Of Cubicle Boards / Ladder / Solar Structure 52 Panel Boards Shifting / Dismantling 53 Labour Charges For Dismantling Of Old Industrial Type Panel And Handed Over To Emc Stores. 54 Panel Boards Shifting And Erection Charges Including Channel Provision & Connection Etc As Required R N 55 Main Motor Control / Oven Control Panel Erection Charges In Including Channel / Angle With Bolt Grouting With Necessary Connection Etc As Required. R N 56 Supply And Laying Of Rubber Mats / Fabricated Chequered Plate / Ms Plate For Following Size With Bottom Support And Necessary Cutting, Grinding, Welding, Erection Including Painting And Transport Charges Etc. As Required. 57 Chequred Plate Thickness 4Mm R N 58 Electrical Insulating Mats Class: A Conforming To Is:15652:2006, Thickness: 2.0Mm 59 Supply Of Electrical Items 60 Repairing And Painting Works. 61 Removing And Fixing Of 3Ph Dbs With Necessary Arrangements. 62 Supply And Installation Of Three Phase Starters 63 Supply And Installation Of 3-Ph, 415V Sheet Steel Enlcousre Type 1.0-5.0Hp Dol ( Direct- On-Line ) Motor Starter Protecte With Olr With Necessary Arrangement Etc. As Required. 64 Supplying Of Cables. R N 65 Supplying Of Following Size Isi Marked Pvc / Xlpe Insulated And Pvc Sheathed Aluminium Grade With Armoured As Required. ( Make:Finolex, Gloster, Polycab And Havells With 18 Months Warranty From The Date Of Supply ) 66 3½ X 120 Sq Mm 67 3½ X185 Sq Mm 68 Supplying Of Following Size Isi Marked Pvc / Xlpe Insulated And Pvc Sheathed Armoured Copper Conductor Cable Of 1.1 Kv Grade As Required. ( Make:Finolex, Gloster And Polycab ) 69 4X10 Sq.Mm 70 3X2.5 Sq.Mm 71 3 X 4Sq.Mm 72 24X1.5 Sq.Mm 73 Supply Of G.I Pipes And Angles 74 Supplying And Erection Of Following Size Medium Class Pvc Pipe Bended To Required Shape Having Threaded Top End With Chucknuts To Fix In Looping Box, And Fixing In Pole Coller / Foundation As Required. T T T T T T T R 75 32 Mm Dia.Pvc. Pipe ( Medium Class ) 76 Adaptor Box 77 Cable Adaptor Box ( Market Item ) R N 78 Supply And Installation Of 300X250x100mm Deep M.S Adaptor Box Along With 12Way Porcelain Type Terminal Connector Made Out Of Not Less Than 2.2 Mm Thick Ms Sheet Connection Inter-Connection, Powder Coating Painting Etc. As Required With Necessary Angle / Channel In The Ground Arrangement Etc. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
42.
Public Administrative Department #10560345 Price Bid
Tender For Estimate Of Pipe Line Work, Column, Sluice Valve, Duct Foot Bend All Other Work Etc Complete, 1 Excavationofearthinordinarysoil(loam clay or sand) for pipe line and rising main trenches including lift upto 1.50 m and lead upto 50 m and refilling watering ramming of theexcavatedearthintothetrenchand also disposal of surplus earth upto 50m from the center of the trenches including supply of all material labour T&P etc complete as per instructions of Engineer -in -charge.In ordinary soil 2 Supplying and cartingthe following dia DI butterfly /sluice valves, duct foot bendworkingpressure10Kg/cm2 confirming to IS: 780/1969 or its latest amendments, including valve fittings & Dismantling Joints as per requirement F.O.R. destination,andloweringthemintothe alreadypreparedtrenches,completeand alsoincludingsupplyofjointingmaterials etc. complete .including all taxes and insurance, as per instructions of Engineer -in - charge.250 mm dia sluice valve D/F 3 200 mm dia duct foot bend D/F 4 100mm x 80mm reducer D/F 5 Supply of all materials, labour T&P etc. and construction of air valve chamber complete required for proper completion of the work as per type design(with RCC cover) 6 Design and construct Thrust Block made inR.C.C. with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3, for pipe line, including supply of MS reinforcement wrought to required shape as necessary ,its bending, fixing & binding the samewith0.50mmthickbindingwirein position & necessary centering & shuttering including curing and supply of all materials, labour,T&Petc.requiredforproper completion of the work and as per specificationsforRCCworkasper instructions of Engineer -in -charge. 7 Supply and carting of following sizes of G.I. Pipeforbyepasssystem withalljointing materialsandspecialswithloading unloading . or carting from store to site of work. Lowering the same into trenches and laying to true alignment and gradient includingtestingofpipelines(excluding trenching), but including cutting of pipes for making joints.All complete as per instructions of Engineer -in - charge.80 mm dia G.I. 8 Ist class brick work in 1:1:5 cement ,coarse sand & localsand mortarin super structure including supply ofallmaterialslabour T&Petc.requiredfor proper completion of work . 9 Supplyandfixingofclampironincludingtheir cuttingandmouldingandweldingtorequired shape also including other material such as nails and screws etc. required for proper completion ofthe work. 10 12mm thickplaster withcement localsand mortar in 1:5 (over brick work with 3 mm floating coatofneatcementincluding supply of all materials, labour,T&P etc required for proper compltionofwork.FromGLuptosuperstructure. 11 100 mm thick concrete with 40 mm gauge brick ballast,localsand&Cementinproportionof 12:6:1 in foundation including supply of all materialslabour,T&Petc.requiredforpropercompletion of the work . 12 R.C.C.workwithcement,coarsesandand20 mm gauge stone ballast in proportion of 1:2:4 in following excluding supply of reinforcement and itsbending,butincludingitsfixingandbinding thesamewith0.50mmthickbindingwireand includingnecessarycentringandshuttering supply of all materials, labour, T&P etc. requiredfor proper completion of the work. 13 GST @ 18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Uttar Pradesh View Result →
43.
Water Resources and Irrigation #10558790 Price Bid
Supplying, Installation, Testing & Commissioning of Mix-flow type Electric Pump Sets & equipments with all accessories etc. including development of Substation for New Pump House at Jahangirpuri drain near Gopalpur Regulator RD-1135m.- 1 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 55 KW/75 HP , 6 Pole , 980 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 35x35 Size Pump set having 1400 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 2 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 75 KW/100 HP , 8 Pole , 740 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 40x45 Size Pump set having 2000 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 3 Supplying , installation, testing and commissioning of Sound Proof Steel enclosure Water Cooled Engine coupled with Alternator 320KVA/256 KW silent DG Generator set including Base frame, Radiator/Heat Exchanger/Fuel Tank/ Control Panel /AMF panel, fuel piping foundation, all interconnections, loop Earthing, Silencer completed all as per CPWD/CPCB norms with standard accessories etc. as required.(Make:- Crompton Greaves/ Kirloskar/ Cummins or as approved by Engineer-in-charge) 4 M.S. Pipes:-Manufacturing , Supplying, erection & commissioning of Mild Steel ERW, (Electric Resistance welded) Pipe fabricated/manufactured out of Fe410 Mild Steel Grade 330 as per IS: 3589 of reputed & approved make , including painting with epoxy paint inside and outside surface with two coats of anticorrosive paint of approved brand and manufacture : all conforming to relevant IS codes: complete in all respect and with upto date amendments in relevant IS codes:(Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge)1200mm nominal dia pipes of 12mm thick complete as required at site. 5 350mm nominal dia pipes of 8mm thick complete as required at site. 6 400mm nominal dia pipes of 8mm thick complete as required at site. 7 450mm nominal dia pipes of 8mm thick complete as required at site. 8 MS Flanges:- Manufacturing, Supplying, fixing & welding of following sizes M.S. Flanges etc complete. as requiredat site. 1200mm dia. & 25mm thickness. 9 350mm dia. & 20mm thickness. 10 400mm dia. & 20mm thickness. 11 450mm dia. & 20mm thickness. 12 MS Bends:-Manufacturing, Supplying, fixing & welding of following sizes M.S. Bends etc. complete. as requiredat site. 1200mm dia. 13 350mm dia. 14 400mm dia. 15 450mm dia. 16 MS Dummy Flanges:-Manufacturing, Supplying & fixing of M.S. Dummy Flanges etc. of following sizes complete as required at site. 1200mm dia. & 25mm thickness. 17 350mm dia. & 16mm thickness. 18 400mm dia. & 25mm thickness. 19 C.I. Sluice Valves:-Providing & Fixing of following sizes Cast Iron Sluice gate Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 20 450 mm nominal dia. 21 C.I. Non Return Valves :-Providing & Fixing of following sizes Cast Iron Non Return Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 22 400 mm nominal dia. 23 Nut/Bolts/Washers:-Manufacturing & Supplying of Nuts,Bolts & Washers etc. of size 7/8 x 6 as required at site. 24 Rubber Gaskets:-Manufacturing, Supplying & Fixingof Rubber Gaskets of thickness 6mm or more for following sizes M.S. Pipelines Flanges as required at site.1200mm nominal dia. 25 350mm nominal dia. 26 400mm nominal dia. 27 450mm nominal dia. 28 Vaccum Pump:-Supplying, Installation, Testing and Commissioning of DV-50 Vaccum Pump sets having C.I. casing and C-40 shaft with 10 H.P. energy efficiency LV motor, 3 phase, 415volt 50hz, 1500RPM +/- 5%, TEFC induction motor mounted on suitable size M.S.base frame coupled on existing foundation withall accessories like ML 1.5 starter, anti vibration mounting pad, coupling, nut-bolts & packing etc. complete in all respect i/c providing, fitting & testing ofheavy class M.S. pipe of 50mm dia.of requiredlength with necessary Gate valve and mountings etc.for chargingof pump sets. ( Pump:- Kirloskar make or as approved by Engineer-in-charge) (Motor:- Kirloskar/Crompton /ABB or as approved by Engineer-in-charge) (Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge) 29 Supplying, installation, testing & commissioning of Energy efficient 630 KVA, 11/0.433 KV, 3 phase, 50Hz, Dyn11, outdoor ONAN type, copper wound Transformer with off load tap changing arrangement on HV side , Tapping range +5% to -10% in steps of 2.5%having Cable boxes on HV/LV side suitable for 3 x 240 Sq.mm. XLPE Cable of 11 KV grade with accessories, buckholz relay i/c first filling of filtered dehydrated oil and confirming to IS 335& Transformer losses as per IS 1180 level-2 & as per specification attached complete in all respects as required at site. • Max Continuous Rating = 630 KVA • Voltage Ratio = 11/0.433 KV• Tapping (Range/ Step) off Circuit Tap Changer = +5% to -10% in step of 2.5% off load • Insulation Class = A Class • Application of the Transformer = Distribution• Vector Group = Dyn 11• Temperature Rise at Rated Load over Ambient of 40°/50° C• Cooling = ONAN(Make:- Kirloskar/Schenider/ABB or as approved by Engineer-in-charge) 30 Supplying, Installation, Testing and Commissioning of Indoor Type Floor Mounted metal clad, 11KV VCB Panel with 1 No. VCB for ICOG System (Incoming-Outgoing System), Totally Enclosed. Horizontal drawout, Horizontal/Vertical Isolation type Breaker as per IS 13118 & as ammended upto date and additional specifications as mentioned below, manually charged and motorized /manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated Aluminium Bus Bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 3 x 95 sqmm XLPE 11 KV cable (cable entry frombottom/top/side) (MAKE:- Kirloskar/ L&T/ Crompton/Schenider)1. All CTs and PTs shall be cast resin type.2. 2. All PTs should be Fixed type.Detailed Specifications:-1 Nos. 800A TP Electrically drawout type Vacuum Circuit Breaker, 11KV, 20KA/3 seconds suitable for 630A TP, EDO, 18.4KA/1 second with following accessories:a)Spring Charge Motor, 240V A.C, Closing Coil 24V DC, Shunt Trip Coil 24V DC, Operation Counter with Mechanical ON/OFF Push Buttonb)Mechanical Indicator ON/OFF, Aux. Contacts 4NO + 4NC, Spring Charge/Discharge,Mechanical Spring Charging Device.c)Mechanical Emeregency Push Button2. 1 No. 11 KV / 110V PT class 0.5 accuracy and 100 VA burden with 1 No. voltmeter (0-15 kV), digital type, selector switch for voltmeter and protection fuses / MCB for HT metering up to 12 KV on incomer.3. 1 No. Microprocessor based numerical relay with O/L,E/F and S/C protection.4. 1 sets of 3 nos dual core dual ratio CTs 50/50/5/5A of 15 VA burden and accuracy class - 0.5 for metering and class 5P 10 for protection.5. Flush mounted Type High Speed Tripping Relay,6. Flush mounted Type DC Operated Auxiliary relay for Transformer Faults with Three Pair of Relay Element7. 1 Nos. Anti Pumping relay8. Annunciator Set 8 Window Type with Hooter for Fault Indication9. Supplying, Installation, Testing and Commissioning of Power pack with 220 volt AC input & 24 volt DC continuous output suitable for closing / tripping / indication of 1 No. HT Panel Boards with 2 Nos. 12 volts each maintenance free batteries of 100 AH each, charging unit, capacitor bank for emergency delivering for Trip system complete with suitable capacity of Ammeter & voltmeter i/c connections with 2.5 sqmm FRLS insulated copper conductor cable etc. as required. 31 Fabrication Supply Installation Testing and Commissioning of Main L.T Panel suitable for 415 Volt, 3 Phase 4 Wire System, 50Hz AC Supply. Panel Shall be fabricated out of 1.6MM thick CRCA Sheet for load bearing and non load bearing members, Gland Plate shall be fabricated out of 2MM thick CRCA Sheet. Panel shall be Powder coated with RAL 7032 Shade for Doors and Body and have suitable solid links for Incoming ond Outgoing of the ACB with Electrical Grade Aluminium of 1000 Ampere Capacity supported on DMC/SMC Bus Bar Supports. Earthing shall be done with 25 X 5MM G.I Strip running acroos the Panel Length. The Control Wiring for Metering and Display Instruments shall be done with PVC Insulated 1.1KV Grade multi stranded copper wire of 2.5 Sqmm. Proper Ventilation system for heat disipation shall be provided with Panel including ventialtion fan and louvers. The Panel Shall not be less than 1875 X 2000 X 750 m.m or Cm³(H,L&D) The Panel shall be fitted with the following switchgear & instruments as mentioned below:-Incoming:-a)1000A TP ACB, Manually Type with following protection features such as Overload and Shor Circuit protectionb)Digital Type Multifuntion Meter, bearing Cl 1 Accuracy without RS485 Portc)Phase Indication Lamps for R-Phase, Y-Phase and B-Phase, 240V A.Cd)ACB ON and OFF Indication Lampse)6A SP MCB, 10KA Breaking Capacity for Protection and Control Circuitf)1 Set of 1000/5 CT, CL-1.0, 15VA Burden Tape WoundOutgoing:-a)55KW Star Delta Starter with ML4 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosb)30KW Star Delta Starter with ML3 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosc)400A TP MCCB, 36KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nosd)200A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.e)125A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.f) 100A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nos. 32 Supplying, installation, testing & commissioning of Cubical Type Phase sequence corrector suitable for 415 Volt, 3 Phase 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2mm thick CRCA sheet of size for frame work and covers, having Gland plate less than 3mm including cleaning and finishing complete with powder coating in approved shade, having links not less 600A capacity. the Bus Bar support (wherever required) with short curcuit withstand capacity of 31 MVA for 1 sec.Entire panel shall have a common Earth Bus of suitable size at the Rear with 2 Nos. Earth stud, solid connections from main Bus Bar to switch Gears with requires size of Aluminium Bus Bar (wherever required) and control wiring shall be done with 2.5 sq.mm PVC insulated copper conductor single core cables. Including providing and fixing the following switch Gear.A) Materiala) 580A Three Pole Power Contactors, AC3 Duty, Coil voltage 220 V A.C: 2 Nos. (Make:- ABB/L&T/C&S)b) LED type indication Lamps RYB (3 set) Aux. Supply: 220V A.Cc) Control Miniture Circuit Breaker (3 Nos.) SP, 10KA : 6Ad) Single Phase Digital Type Ampere Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 accuracy, CT-Input-5A, Aux. Volt-220V,ACe) Ampere Selector Switch (1No.) Rating : 6Af) Single Phase Digital Type Volt Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 Accuracy, Range:- 0-500 V, Aux. Volt:220V, A.Cg) Voltage Selector Switch (1No.) Rating : 6Ah) Current transformer 600/5A, Single Ratio, Single Core, 1Ø (3 Nos.) , Tape wound, CL-1.0 & 15VAi) LED type Indication LampsON/OFF (2 set) Aux. Supply: 220V A.Cj) Auto/ Manual selector switch (2 Nos.), Rating : 6Ak) Phase Sequence correction relay (1 Nos.) Aux Volt :220V, A.Cl) Audio Indication for Phase sequence Reversal(1 Nos.) Hooter : 220V A.C.m) On Delay Timer (1 Nos.) Aux Volt :220V, A.C 33 SITC of 200KVAR APFC Panel made out of 1.6mm Thick CRCA Sheet duly powder coated complete with suitable size of Al. Bus Bars & internal wiring with suitable size of Copper wire including Providing and Fixing following Switchgear and Metering instruments complete as required. Panel size shall not be less than 1575m.m or Cm³*1900*350.. the Capacitors Shall be Divided as per the mentioned Pattern for 200KVAR SystemA) MaterialMain Incomer:-a) 400A TP MCCB, Thermal based Release with O/L & S/C Protection: 1 Nos.b) Rotary Operating Mechanism: 1 Nos.c) Phase Spreaders: 1 Setd) 12 Stage APFC Relay, Microprocessor Based, with Different Display Parameters.e) Phase Indication Lamps, 220V-240V AC : 3 Nos.2) Outgoing:-a) 63A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 6 Nosb) 40A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.c) 25A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.3) 200 KVAR Capacitor, MPP and Cylindrical Type:-a) 25KVAR Capacitor Bank: 6 Nos.b) 15KVAR Capacitor Bank: 2 Nos.c) 10KVAR Capacitor Bank: 2 Nos.4) Capacitor Duty Contactors of Various Ratings for Capacitor Switching:-a) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 25 or Equivalent : 6 Nosb) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 15 or Equivalent : 2 Nosc) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 10 or Equivalent : 2 Nosd) Side Mounting Block : 10 Nose) Push Button with Element Set for Manual Start & Stop of Capacitor Bank : 10 Setsf) Indication Lights for Capacitor ON Indication : 20 Nos.g) 4 Ventilation Fans with Louvers for Cross Air Ventilation : 1 Nosh) Auto/Manual Selector Switch for Auto/Manual mode of Operation : 1 Nos. 34 Copper Conductor LT Cables:-Supplying, Laying and fixing of following sizes P.V.C. insulated and P.V.C. sheathed/ XLPE CopperConductorarmoured Cable of 1.1 KV grade as per IS:1554 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)4C x 10 sqmm. 35 4C x 120 sqmm 36 4C x 150 sqmm 37 Aluminium Conductor LT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 1.1 KV grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)3.5C x 300 sqmm 38 3.5C x 150 sqmm 39 Aluminium Conductor HT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 11 KV(E) grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. 3.5C x 300 sqmm(Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge) 40 Supply and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 sq. mm 41 4 x 35 sq. mm 42 4 x 10 sq. mm 43 Supply and making outdoor end jointing with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 11 KV grade as required.3C x 300 sq. mm 44 Supplying & fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth busbar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 6 way, Double door 45 8way, Double door 46 Supplying and fixing metal box of 100mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 47 Supplying, installation, testing & commissioning of energy efficient LED Flood light luminaries of system wattage 72 watt complete with mounting brackets & accessories i/c connections complete as required.(Make:- Bajaj/Philips/Crompton/Halonix) 48 Supplying and fixing followingpiano type switch/socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch 49 15/16 amp switch 50 3 pin 5/6 amp socket outlet 51 6 pin15/16 amp socket outlet 52 Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. 53 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, , miniature circuit breaker suitable for inductive load of folloeing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole 54 Single pole and neutral 55 Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVS insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular plate, sitable GI Box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) 56 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2x2.5 sq.m + 1x2.5 sq.m earth wire 57 2 x 4 sq. mm +1 x 4 sq.mmearth wire 58 Supplying, installation, testing and commissioning ofHeavyduty following sizes exhaust fan 900 RPM totally enclosed heavy duty motor with die castaluminium rotor suitable for operation on 240 volts 50 Hz AC single phase Supply including installation of exhaust fan in the existing opening, making good the damages as required. .(Bajaj, Usha, Khaitan, Havells, Orient ) or as approved by Engineer-in-charge.450 mm Sweep 59 Supplying, installation, testing and commissioning of 1200 mm sweep AC electric ceiling fan capacitortype with double ball bearing complete with down rod, canopies, shackles, blades but without regulator suitable for operation on 230/240 volts, 50 Hz single phase AC supply including wiring the down rod of standard lenth up to 1 mtr with 2x1.5 sq. mm PVC insulated copper conductor with fan sheet etc. as required.(Make:- Bajaj/ Usha/ Khaitan/ Havells/ orientor as approved by Engineer-in-charge) 60 Supplying, installation, testing & commissioning of prewired Indoor decorative 18/20 watt LEDbatten extruded aluminum housing& opal diffuser. IP20 complete with all accessories including connection making etc. as required. (Make:- Bajaj/ Halonix/ Havell’s/ Crompton/ Phillipsor as approved by Engineer-in-charge) 61 Supplying and fixing of following size P.V.C. insulated sheathed /XLPE Aluminum conductor cable of 1.1 KV Grade armoured as per IS:7098 on surface as required. (National,Grandlay, Glouster, Poly-Cab, Phinolex or as approved by Engineer-in-charge). 2 x 10 sq.mm 62 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 63 Providing and fixing 25 x 5 mm G.I.strip on surface or in recess including connection etc. as required. 64 Providing and laying 6 SWG G.I wire on surface or in recess for loop earthing along with existing surface/recessed/conduit/submain wiring/cable etc. as required. 65 Supplying, Installation, Testing and commissioning of 7.5 Tonne capacity Single Girder E.O.T. Crane comprising of Main Girder, End carriages -02 nos with long travel motors – 02 Nos, 01 Nos 5 Tonne capacity Wire Rope Electric Hoist, pendant controlled along with brakes, limit switches and electric panel. All motors i.e. Hoisting/ Lowering, cross travel and long travel shall be compatible with VVVF drive and the speeds can be adjusted from zero to maximum speed. The complete system includes erection of columns, LT Girders, LT rail/ Sq Bar, 01 no DSL system (Shrouded type)(MAKE: - GLOBE/ WH BRADY/ GARLIC) 66 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 150 Watt LED street lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge) 67 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 100 Watt LED Flood lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge). 68 Fabrication & installation of S.S. Bar Screen/ Jaal inside Suction side of Pump Sump in slightly inclined position of required height with M.S. Platform etc. for ease of removal of foreign materials, hyacinth, jute, bags etc. from the suction side completed etc. as required at site.Construction, maintenance and subsequent removal of earthen bundies including cost of excavation earth filling of E.C. bags with earth, stitching and placing in position for care and diversion of all kinds of water entering or flowing in the drain and pumping out surface as well as under groung seepage water to keep the construction area completely dry for execution of entire work including its execution of work in or under water and or liquid mud wherever required with round the clock watch & ward/maintenance of earthen bundies to keep the working area/site dry complete as per specification & direction of Engineer-in-charge. 69 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. 70 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 71 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cementconcrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverableseparately). All works upto plinth level. 72 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 73 Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as Nuts, Bolts,fasteners etc.).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
44.
Civil Aviation #10546587 Price Bid
Tender For Provision Of Guard Lights At Tuticorin Airport; 1 SITC of FAA/ICAO/DGCA-CAR compliant LED based Runway Guard lightfor compliance as per ICAO/DGCA-CAR aviation visual aids requirements complete with LED lamp/s with integral driver, electronics suitable for operation along with existing 2.8-6.6 Amps current Circuit & CCRs , with all accessories and cable lead with plug ready for site installation on circular Housing box ,suitable for all weather operation, conforming to latest ICAO / CAR requirement as per specifications complete as required. 2 Supply of45 W, 6.6A/6.6A rating 5000V, 50 Hz Series Isolating Transformers encapsulated in black cross linked polychloroprene compound like TPE /TPR / TPV with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned LED runway Guard light fittings complete as per Technical Specifications. 3 SITC of CI Adaptor / collar box round type of outside dia 330mm of 150mm height made of 10 mm thick cast iron moulding all round except on top surface which is 15 mm thick cast iron moulding suitable to receive a light fitting base plate on the top. The CI collar shall have a clear opening of 220 mm at the top and bottom surface and 6 nos M-10 tapped holes at the centre of 260 mm at top and bottom to fix the collar including providing 6 nos. M-10 bolts (SS) and a base. The cost shall include necessary bitumen/concrete kerf/core cutting and concrete works for fixing the same and laying of connceting pipes. 4 Installation of CI Transformer housing box with a base concrete of 1:3:6 of size 630*630*100mm thick all round concrete of 1:2:4, 150mm thick top sloped with 1:2:4 cemeny concrete including excavation of existing Bituminous Road/Pavement/shoulder of the runway, disposal of material within 50 mtrs lead, providing and fixing 300mm long 1/2 dia B class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling. The boxes are aligned in such way that the hole centres fall in straight line etc., complete as required. 5 Supply of 2C x 4 sq.mm., 600V Grade Flexible Copper Conductor, EPR insulated & CPE (Chlorinated Polyethylen, cross - linked, heavy duty) outer sheath (Black colour) Secondary cable for Airport lighting circuits conforming as specified in particular specification sizes as required. 6 Supply and installation of 2 pin secondary plug suitable for connection of isolation transformer and to light fixture complete as required 7 Supply of plug & receptacle of size 6 sqmm type I, class B connector & suitable for attachment with 5 KV grade XLPE insulated PE sheathed single core screened copper conductor cable as required. 8 Laying of one number of PVC insulated and PVC sheathed cable of 5KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. 9 Providing and Laying of 25 mm dia B class GI Pipe in Runway for runway guard light fittings. Job Involve kerf cutting and refiling the same with (fast grouting) cement concrecting complete with threading and alignment of pipe with transformer housing box as required. 10 Supply offollwing size5 KV Grade stranded Copper Conductor single core PVC insulated, PVC sheathed, unshielded, anti-termite and rodent treated, airport lightingcable generally confirming to IS 1554- Part-II 1981 with up to date amendments and as specified in particular specifications of the following sizes as required. 1 Core X 6 Sq mm. 11 SITC ofIndoor, Air cooled Type constant current regulator of Thyristor Controlled microprocessor based suitable for use on 230V+ 10% volts, 50/60 Hz, Input AC Supply with Output Power of 7.5 KW at 6.6 Amps with 5 Steps variation of Current Output suitable for local and Remote Control Operation with 24/48 VDC integral Control Supply complete with output current indicated on multifuction digital display, over current, over voltagte, earth fault protection and earth leakage meter, positive feed back indication equipments,complete with 5 KV grade current transformer and relays, contactors interconnection with multicore control cable junction box etc complete as per AAI specifications as required. (The CCR should be supplied with modules connecting to available NASU make ALCMS system at Tuticorin Airport) 12 Supplying and Laying of HDPE pipe of 63mm OD of PE 80 PN 6 ISI marked along with all accessories like socket, bend,couplers etc. confirming to IS 4984,complete with fitting and cutting, jointing etc. direct in ground at a depth of 0.8m below the ground level i/c excavation and refilling the trench but excluding sand cushioining and protective etc as required. 13 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 14 Supply of following size of XLPE insulated PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 2 core x 25 sq.mm 15 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2Cx 25 sqmm 16 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, getting out the excavated soil, refilling with excavated soil after laying of cable/ pipe/ for site requirement etc. and disposal of surplus excavated soil as directed, within a lead of 50 meters, without ramming and watering etc as required. 17 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 18 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of upto 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe/ Masonary Duct as required. 19 Supply of following size of XLPE insulated PVC sheathed copper conductor armoured power cable of 1.1 KV grade conforming to IS-7098 Part-I amended upto date etc. complete as required. 12Cx 1.5 sqmm
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
45.
Health and Family Welfare #10546188 Price Bid
Ct Scanner 16 Slice With Flat Table Top Couch(Ct Simulator) Ct Scanner 16 Slice With Flat Table Top Couch(Ct Simulator) , Ct Scanner 16 Slice With Flat Table Top Couch As Per The Specification Except The Following , Additional Work Station , Dry Imager , Pressure Injector With Syringes , Full System Ups , Lead Glass , Light Weight Vinyl Lead Apron With Thyroid Shield , Gonad Shield , Music And Patient Address System With Speakers , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Buy Back Offer Of Old Ct Simulator Available At Mch Kohikode , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation) , Ct Fluoroscopy (Not Taken For Evaluation) , Branded Personal Computer With Printer (Not Taken For Evaluation) , Led View Box 3 Film (Not Taken For Evaluation) , Apple Osrix Workstation (Not Taken For Evaluation) , Neuro Package Including Neuro Dsa & Neuro Perfusion (Not Taken For Evaluation) , Spectral Package Including Twin Spiral Spectral Viewing, Dual Energy And Calculi Characterization (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
46.
Power #10545468 Price Bid
Tender For Repair & Maintenance Of Office Building With Raising Of Floor At Sub Division Office Laxmangarh - Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:Of area 3 square meter and below. 3 (B-156/14.2.1)Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix. 4 (B-14.29)Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: 5 4.1Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 6 4.2Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 7 (B-59/4.3)Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 8 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :(A) Columns, pillars, posts and struts etc. (4.10.3) 9 (B-61/4.10.2)Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 10 (B-62/4.13.2)Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Hot rolled deformed bars (IS : 1139). 11 (B-107/10.17.1)Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 12 (B-109/10.22)Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 13 (B-140/12.7)Finishing with neat cement (punning). 14 (B-162/14.55)Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 15 (B-65/5.2.2)Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 16 Halfbrick masonry in superstructure, above plinth level upto floor V level using bricks of designation 75.Cement mortar 1 : 4 (1 cement : 4 coarse sand) (1cement:6 coarse sand). (5.8.2) 17 S & F in walls machine cut and polished stone shelves,tands and in 1:3 with machine cut edges:(A) Kota stone minimum 30 mm thick (6.17.3) 18 (B- /13.12)Repair to stone masonary in cement sand mortar 1:6 with old and new stone. 19 11.26Random rubble dry stone Kharanja under floor. 20 1.8E/W in excavation by mechanical means (hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5m in whichor 10 sqm on plan) including dressingof sidesand ramming of bottoms, lift up to 1.5 m, including taking outthe excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 21 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. (A) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (3.1.6) 22 (B-139/12.3.2)Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:20mm thick. 23 (B) 12mm thick (12.3.3) 24 (B-139/12.5)6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 25 (B-139/12.3.1)25 mm thick 26 (B-142/12.22.1)Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.(A) New Plastered Surface (three or more coats) 27 (B-144/12.37.1)Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping andpriming coat with cement primer. 28 (B-145/12.42)Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 29 (B-146/12.46.1)Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(A) Two or more coats on new work 30 9.5/B-9Providing & fixing T-iron frames for doors, windows and ventilators of mild steel Tee - sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 31 (B-93/8.13.2.1)Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick .Commercial Veneer both side 32 (B-93/8.14)Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 33 (B-146/12.45.1)Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 34 9.17/B-9P/F MS sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitable diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra i/c all fittings, as per direction of E/I but excluding cost of chowkhats i/c two coats of anti corrosive red oxide primer paint MS sheet 20 S.W.G 35 (B) Extra for double leaf shutters. (9.17.1) 36 (B-56/3.8)Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification : 37 7.25.1P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size600 mm X 600mm 38 10.33.2Providing & fixing calcium silicate perforated ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:-8 mm thick 39 P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge. (9.39) 40 (16.1.1.1)P & F anodized aluminum work (Anodized to be got done from approved Anodiser) for doors, windows, ventilators and partition with extruded built up standard tubelar and other sections of approved make confirming to IS : 733 & IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasters i/c necessary filling up of gas at junctions, at top , bottom and sides with required PVC / Neoprene felt etc. aluminium section shall be smooth, rust free, straight, mitered and jointed mechanically wherever required i/c cleat angle Aluminium snap beading for glazing/paneling , C.P. brass/stainless steelscrews, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer in charge.(Glazing and paneling to be paid for separately). (a) For fixed Portion.Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 41 (b) For shutters of doors, windows and ventilators including P&F hinges / rollers etc. and making provision for fixing of fittings wherever required( locks shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) (16.1.2.1) 42 16.2Extra for shutters of slidingaluminum windows 43 16.5.2/B-16 P&F glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/Neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer in charge.(Cost of aluminium snap beading shall be paid in basic item.). With glass panes of 5.0mm thickness (weight not less than 13.75 kg/S.pm.) as per IS: 2835. 44 16.11S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. 45 8.7 (a)Extra for providing frosted glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 46 16.15Providing and fixing sun control film, thickness of film 1 Mil Visible Light Transmittance 4-24% & Solar Energy Transmittance 42-51% & Total solar Energy rejection 37-43%of approved colour and shade , complete in all respect , at all level , as directed by engineer- in -charge. 47 (16.44.2)Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 50mmx48mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Powder coating aluminum ( minimum thickness of powdercoating 50 micron) 48 16.4.1/B-16 P&F 12mm thick prelaminated three layer medium density (exterior grade) particle board grade 1, Type II conforming to IS: 12823 bonded formaldehyde synthetic resin of approved brand and manufacture in panelling fixed in aluminium doors, windows shutters and partition frame with C.P. brass/stanless steel screws etc. complete as per archituctural drawing and directions of engineer in charge.Pre-Laminated particle board with decorative lamination on one side and balancing lamination on other side. 49 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 50 9.8.1(A) Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 51 (S-247/3.16.3)P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.(b)110 mm dia 52 (S-248/3.17.9.(ii))P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87.5-110 mm dia 53 (S-249/3.17.12(ii))Vent Cowel 110 mm dia 54 (S-248/3.17.3(ii))Plain Tee110 mm dia 55 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. (A) Short point (up to 3 mtr.) (1.1.1) 56 (B) Medium point (up to 6 mtr.) (1.1.2) 57 © Long point(up to 10 mtr.) (1.1.3) 58 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR On board (1.3.1) 59 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR (7.36) 60 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR(A) 2 x 2.5 sq. mm. + 1x1.5sqmm (4.1.7) 61 (B) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (4.1.14) 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 8 SWG G.I. ( Hot Dipped) Wire. (14.6.8) 63 14.2Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 64 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing. (17.2.2) 65 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 mm Dia. (18.18.1) 66 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR. (5.9) 67 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics). 6 A to 32 A rating. (6.1.1.2) 68 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR. Four pole Isolator. 63 A rating. (6.2.3.2) 69 6.10.3.4Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR.Metal door (Three phase) IK-09 and IP-43with Metal end box.12 Way 70 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR(A) 6.0 Sq. mm 2 core. (11.2.2.1) 71 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(A)LED Street Light fixture with Minimum lumen output 11225 lm. (18.12.6) 72 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg. (24.67.3) 73 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.12) 74 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.13) 75 Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.20) 76 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) (15.7.1) 77 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(B) Surface MoutningMinimum lumen output 4200 lm. (17.4.2.3) 78 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Mounting (with extruded alumn. Housing )(B) Minimum lumen output 1300 lm. (17.3.2.2) 79 7.26Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 7.27.3Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. 10 A bell push
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
47.
Rural Development #10544314 AOC
tender for 1 Working benchmark Pillars - Setting Out PillarsProviding & Fixing of Working benchmark Pillars 2 nos. per km& 6 Nos. of reference pillars required for 1 Km. as per drawings given and direction of E/I 2 Reference pillars - Setting Out PillarsProviding & Fixing of Working benchmark Pillars 2 nos. per km& 6 Nos. of reference pillars required for 1 Km. as per drawings given and direction of E/I 3 Clearing and Grubbing Road Land (By manual means)including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees ofgirth upto 300mm, removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification clause 201.1 and direction of E/I 4 Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 100 m as per Technical Specification Clause 301.5 5 Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification. 6 Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. GRADING - II 7 WBM GRADING - II - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with threewheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. 8 WBM GRADING - III - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification. 9 Providing and applying primer coat with Bitumen emulsion (SS-1)on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. 10 MIX SEAL SURFACING - Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509. 11 Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface tretaed with Primer and clened with hydriloc broom as per technical specification aclouse 503. 12 KM Stone- Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703. 13 200 M Stone- Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703. 14 Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 (For culverts) 15 Cable Duct Across the Road - Providing and laying of a reinforced cement concrete pipe duct,300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills,constructing head walls at both ends, providing a minimum fill ofgranular material over top and sides of RCC pipe as per IRC:981997,bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings. 16 600 mm equilateral & triangle - Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 17 600 mm circular - Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 18 600 mm x 450 mm rectangular - Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 19 Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 20 Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads@ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35.The finished surface to be level, uniform and free from streaks and holes. (BT) 21 Providing and fixing of typical MMGSY informatory sign board with Logo and Maintenance Board as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 22 Earth work in excavation for foundation of structures upto 3.0 m depth as per drawing and technical specification clause 1104 23 Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108 - rate as per item No. 11.2 (I) of Chapter 11 24 ProvidingPCC Grade M15 for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 25 ProvidingPCC Grade M15 for plain/reinforced concrete in Sub Structure complete as per drawings and technical specifications 26 Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 27 RCC M25in Deck Slab :--Providing and laying reinforced cement concretein superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5 28 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 29 Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications 30 Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per centbitumen by weight 31 Drainage spouts complete as per drawing and technical specifications Clause 1209.
Contract Date: Feb 25, 2026 Contract Value : 11.10 Lakh
Government Departments No of Bidders 2
48.
Drinking Water Supply and Sanitation #10523073 Price Bid
Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities 2 Design, Construction, Supply of all materials, Erection and Commissioning of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities with all the civil,LT/HT panel room, sub station building, DG set foundation, admin buidling, laboratories, meter room and campus development [Construction of Internal Road (CC Road, 3.6m wide, area approx 2000sqm),fiiling of earth if required]fully furnished administrative building having fully functional testing laboratory, PLC/SCADA Rooms, Power Generation building, Blower building, sludge handling system & other building required for technology proposed. OCEMS system at inlet & outlet of STP and master control station (MCS) at STP. Conference room suitable for 15 people, 4 rooms with a attached toilet for supervisory staff and a toilet block, drinking water cooler, all office rooms and conference room (Air Conditioned)., staff quarters as per requirement and specification, external water supply (20KL tank including tube well and pumping arrangement,sanitation work) etc. all complete for STP with co-treatment facilities. STP shall be based on SBR Technology OR any proven technology. The effluent quality for agricultural uses (PH-6.5 TO 8.3, SS-30 mg/l, Oil&Grease-10 mg/l, BOD-10mg/l) , COD-30 mg/l , Residual chlorine-nil , TKN-10mg/l, Nitrate N-10 mg/l, F.C.-230 MPN/100 ml, Dissolved P-5 mg/l (preferable 2 mg/l). ) shall be maintained asper CPHEEO manuals. Latest NGT norms for effluent discharge shall be adhered. The cost is inclusive of (Peak flow 24.11 MLD) (civil works). 3 INTERCEPTOR SEWERExcavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including (8% reduction due to excavation already taken in manhole and SCC) 4 (a)0.00 to 1.50 m 5 (b) 01.50 to 03.00 m 6 (c) 03.00 to 04.50 m 7 Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete 8 (a)1.5 to 3 m 9 (b) 03.00 to 06.00 m 10 Same as item No. 3 but for open timbering (No timbering for depth <1.50m) 11 (a) 1.50 to 03.00 m 12 Timbering left in trenches (No timbering for depth <1.50m) 13 Open Timbering left in trenches (used timbering) 0-3m depth 14 Closed Timbering left in trenches(used timbering)0-3m depth 15 Closed Timbering left in trenches(used timbering)3-6m depth 16 Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).NP3 17 600 mm dia 18 700 mm dia 19 Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment600 mm dia pipe 20 01.50 - 0 3.00 m 21 03.00 - 04.50 m 22 700 mm dia pipe 23 01.50 - 0 3.00 m 24 Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. 25 (c) 03.00 to 04.50 m 26 Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work. 27 (b) 01.50 to 03.00 m 28 Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm)for class B bedding (granular bedding) 29 Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement. 30 1200mm internal dia., 3.30m deep 31 1500mm internal dia., 4.95m deep 32 Extra for every additional depth of 1 m or part there of in following size of circular manholes. 33 1200mm internal dia., 3.30m deep 34 1500mm internal dia., 4.95m deep 35 Dismantling/Cutting of Cement Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer Incharge. 36 Reinstatement of Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer Incharge. 37 Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. 38 Disposal of Surplus Earth as per direction of Engineer Incharge. 39 Construction of Boundary Wall 2.0m ht. above plinth level 0.23m width with RCC Column @3m c/c with plinth beam and foundation avg. 2 m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site 40 MS gate (3.6m wide with 1.50m wicket gate with 0.35 m x0.35m RCC piller) 41 Cnstruction of Intermediate Pumping Station (IPS) as per specification, accesory building & design approved by Engineer in Charge 42 Sewage Rising main from IPS Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer Incharge. 43 0.0 to 1.5 mtr. Depth (do - in all kindes of soil) 44 Supply of 400mm dia. DI K9 pipe and special for the pumping mains including all complete pipes conforming to IS : 8329- 400 mm 45 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.(400mm) 46 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete 150 mm 47 Carting of 400mm dia DI K9 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 48 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing 49 Sluice valve, Air valve chambers 50 Dismantling/cutting of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 51 Reinstatement of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 52 Interception and diversion (I&D) Structure works 53 Cnstruction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge 54 Treated Effluent line (400mm Dia DI K7) (STP to Disposal point (Khow river) 55 Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m.0.0 to 1.5 mtr. Depth do - in all kindes of soil 56 Supply of 400mm dia. DI K7 pipe and special for the pumping mains including all complete Pipes conforming to IS : 8329- 400 mm 57 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.all complete required for completion of work (400mm dia) 58 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. all complete required for completion of work150 mm 59 Carting of 400mm dia DI K7 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 60 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing. 61 Sluice valve, Air valve chambers 62 Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 63 Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 64 E/M WORKS 65 STP ( 7.2 MLD ) And Co Treat ment Plant ( 7 KLD ) 66 A. Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (7.2 MLD )with all required electrical& mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender documentfor STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentrationmentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panelwith considering load of STP and MPS both.B. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 7 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (2 Kl/h 1W+1S), Screw Press Machine (3 KL/H) with double cylinder having VFD for its operation , 1000 Lit. PVC tank for washing screw press machine. all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 2HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run of 1 No. 1500 Lit. Cesspool Vehicle having 30 HP Reputed make Tractor (with Registration Certificate and insurance papers) 67 E./M. Works at MPS 68 Electrical Works 69 H.T.Panel( Comprising with 1 -I/C and 2 -O/G. (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 70 SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 71 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. (1set, included in STP costing) 72 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) (2 sets, included in STP costing) 73 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. (included in STP costing)3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) -60 metersTrench making and covering of trench in all respect.- 60 metersSITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 4 sets11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV - 2.5 SqmTransformer:Suitable capacitywith Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. (included in STP costing) -- 2 Nos. 74 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 63 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 75 LT Cable laying and jointing 76 Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 77 Earthing 78 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 79 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 80 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 81 Charges of Electrical safety Clearance 82 Expenditure on B&L Form, Challan etc. 83 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 84 STARTER PANEL 85 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 86 Mechanical Works 87 PumpThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 3110 lpmTotal Head= 16 M or as per designSpeed=980Quantity of pumps. 88 Guid Rail System 89 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set.(6 Sets, included in item no. 51.01) 90 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (6 Sets, included in item no. 51.01) 91 Main piping and Valves.Main piping and valves 200 mm dia delivery, 350 mm diacommon header line. 92 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 93 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 94 Motor Operated Sluice Valves 95 Sluice Valve 200 mm dia 96 Sluice Valve 350 mm dia 97 Reflux Valve 98 Reflux valve 200 mm dia N.B. 99 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m . 100 200 mm, K9 delivery pipes for all six pumping plant 101 350 mm, K9 common header pipes 102 Specials like bend, tee, D Joint etc. 103 Nut Bolt, Washer Rubber packing etc 104 INSTALLATION, TESTING & COMMISSIONING 105 Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above. 106 Level Transmitter (For Hi-Lo cut-off & alarms) 107 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 108 Electro magnetic flow meter 109 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 110 E.O.T. Crane 111 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 112 Chequerred plate and guards 113 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 114 PAINTING 115 Painting of all pumps piping and valves with two coat enamel paint. 116 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 117 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 118 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 119 IPS Campus with Solar Panel and LED Light of 3 sets. 120 D.G. SET AND ACCESSORIES 121 SITC of Radiator Cooled and Turbo charged Silent type suitable capacity DG set , engine ,alternator capable of developingat 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. (1 set, included in stp costing) 122 SITC of PLC Based Auto main failure (AMF) Panel forDG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect.(1 Set, included in stp costing) 123 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.(2 Job, included in stp costing) 124 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. (2 Jobincluded in stp costing) 125 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. (1 Job, included in stp costing) 126 Providing and Laying cable for DG Set to Panel ( armored aluminium )-(1 Job, included in stp costing) 127 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm. (4 Jobs, included in stp costing) 128 SCREENS AND GATES: 129 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 130 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at mid year peak discharge (1w+ 1s) 131 Packing and Frieght 132 Installation, Testing and Commissioning 133 AUTOMATION OF MPS 134 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 135 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 136 CE/UL certified intellignet Smart Energy Meter 137 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 138 160 AMP rating 139 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 140 CE/UL Certified Surge protector for control panel. 141 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters. 142 Security Survillance IP Camera with recorder 143 Installation, commissiong & testing of above automation work 144 Expenditure on Operation & Maintenance of MPS including automation, Diesel Consumption & Electricity Consuption During 3 month Trial and Run Period 145 E./M. Works at IPS Dhampur 146 Electrical Works 147 H.T.Panel( Comprising with 1 -I/C and 2 -O/G .(panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 148 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 149 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) 150 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 151 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) 152 SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) 153 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break DownVoltage 45 KV 154 Transformer: 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of 315 KVA rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. 155 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 156 SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 No outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay & one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 3 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 400 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 2 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 100 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (E) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (F)APFC Panel for total load.(G) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 157 LT Cable laying and jointing 158 Power and control cable-Supply of 240 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 240 sq. mm X3 core-1 run cable for power from starters to 67 KW Motors & 35 sq. mm X3 core-1 run cable for power from starters to 15 KW Motors including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 159 Earthing 160 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 161 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 162 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 163 Charges of Electrical safety Clearance 164 Expenditure on B&L Form, Challan etc. 165 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 166 STARTER PANEL 167 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 90 HP motor (To be fixed in composite panel of LT Panel) 168 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 169 Mechanical Works 170 Large PumpsThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 90 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (2W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 5750 lpmTotal Head= 40 M or as per designSpeed=980Quantity of pumps. 171 Guid Rail System 172 Guide rail system (Automatic coupling system) for 90 HP submersible pump setscomplete for above pump set.(3 Sets, included in item no. 94.01) 173 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (3 Sets, included in item no. 94.01) 174 Small Pumps 175 Thesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (1W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump=2500 lpmTotal Head= 17 MSpeed=980Quantity of pumps. 176 Guid Rail System 177 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set. (2 Sets, included in item no. 98.01) 178 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (2 Sets, included in item no.98.01) 179 Main piping and Valves. 180 200 mm dia delivery for small pumps and250 mm dia delivery for large pumps, 350 mm diacommon header line. 181 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 182 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 183 Motor Operated Sluice Valves 184 Sluice Valve 200 mm dia 185 Sluice Valve 250 mm dia 186 Sluice Valve 350 mm dia 187 Reflux Valve 188 Reflux valve 200 mm dia N.B. 189 Reflux valve 250 mm dia N.B. 190 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing . 191 200 mm, K9 delivery pipes for small pumping plants 192 250 mm, K9 delivery pipes for large pumping plants 193 350 mm, K9 common header pipes 194 Specials like bend, tee, D Joint etc. 195 Nut Bolt, Washer Rubber packing etc 196 INSTALLATION, TESTING & COMMISSIONING 197 Installation & Commissioning of allPump set,Piping & Valves as mentioned in above @5% of supplied items. 198 Level Transmitter (For Hi-Lo cut-off & alarms) 199 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 200 Electro magnetic flow meter 201 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 202 E.O.T. Crane 203 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 204 Chequerred plate and guards 205 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition(3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 206 PAINTING 207 Painting of all pumps piping and valves with two coat enamel paint. 208 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 209 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 210 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 211 IPS Campus with Solar Panel and LED Light of 3 sets. 212 D.G. SET AND ACCESSORIES 213 SITC of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing 250 kVA at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. 214 SITC of PLC Based Auto main failure (AMF) Panel for 250 KVA DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. 215 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. 216 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. 217 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. 218 Providing and Laying cable for DG Set to Panel 240 sq mm X 3.5 core x 2 run( armored aluminium ). 219 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 240 sq mm. 220 SCREENS AND GATES: 221 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 222 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge (working) 223 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge( standby) 224 Packing and Frieght 225 Installation, Testing and Commissioning 226 AUTOMATION OF IPS 227 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 228 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 229 CE/UL certified intellignet Smart Energy Meter 230 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 231 160 AMP rating 232 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 233 CE/UL Certified Surge protector for control panel. 234 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 235 Security Survillance IP Camera with recorder 236 Installation, commissiong & testing of above automation work 237 3 month trial run of automation work 238 Expenditure on Operation & Maintenance of IPS during 3 month Trial and Run Period 239 Expenditure onDiesel Consumption of IPS during 3 month Trial and Run Period 240 Expenditure on Electricity Consuption of STP, MPS & IPS as per actual UPPCL bill during 3 month Trial and Run Period
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Uttar Pradesh View Result →
49.
Housing Urban and Rular Development #10452608 Price Bid
Tender For Supply Installation Testing Commissioning Of Fire Detection And Fire Fighting System Work In Simulator Block And Firing Rang For Ncc Campus Jln Marg Jaipur -Supplying, Installation, Testing & Commissioning Ofelectrical Driven Fire Fighting Duty Terrace Pump As Per Tac Andis 12469-1988., Factory Assembledin Pump Make Oemsuitable For Automatic Operation And Consisting Of Following Details Given Asa, B, C, D, E, F, G And H. 2 ( A ) Horizontal End Suction Centrifugal Back Pull Type Pump Complete For Delivery Of Below Mentioned Discharge And Head 3 ( B ) Material Of Construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - Ss 410, Packing - Mechanical Seal 4 ( C ) Squirrel Cage Induction Motor ( Ie-3 Class ) Suitable For 3 Phase, 415 V, 50 Hz, Ac Supply , Class -F Insulation, Synchronous Speed Not Exceeding 3000 Rpm, T.E.F.C Confirming To Ip:55 , Of Required Hp Suitable For The Above Pump , Along With Flexible ( Love Joy Type ) Coupling , Coupling Guard Complete In All Respect . 5 ( D ) Common Bed Plate Fabricated Frommild Steel Channel For Installation Of Pump And Motor Including Anti Vibration Pads. 6 ( E ) The Hydrostatic Tests ( 2 Times Of Design Operating Head Or 1.5 Times The Shut Off Head Whichever Is Higher ) And Performance Tests ( To Determine Developed Head, Pump Bhp And Efficiency V / S Flow ) Of Pumps Along With Trip Test Shall Be Carried Out At Manufacturer’S Works In Virtual / Physical Presence Of Department’S Representatives. 7 ( F ) Physical & Chemical Test Reports Of I ) Pump Casing ( Ii ) Impeller ( Iii ) Shaft ( Iv ) Shaft Sleeveand Dynamic Balance Certificate Is To Be Submitted By Oem 8 ( G ) Suitable Size Reinforced Cementconcreat ( M-30 ) Foundation With Foundation Bolt, Nozing Angle Of Size 40Mm X40mm X5 Mm ( Cost Of Rcc Foundation To Be Paid Extra ) 9 ( H ) Weather Proof Hood Fabricated From 5Mm Thick Uv Stablised Frp Sheet Supported By 50 Mm X 50 Mm X 5 Mm Angle Iron Fram Above Pumpset To Protect It From Weather All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 10 900 Lpm With 35 Mtr Head 11 Providing, Fixing, Jointing, Testing & Commissioning Of Heavy Duty Ms C Class ( Heavy ) Pipes Conforming To Is 3589 / 1239 Part-I For Hydrant And Sprinkler Applicationsincluding Cutting, Screwing, Welding Etc. & Forged Steel Fittings Like Elbows, Tees, Tapers, Reducer, Gaskets Etc. Fixing The Pipe On The Wall / Ceiling With Suitable Clamps, Hanger And Nuts Bolts Including Cutting Hole And Chase In Brick Or Rcc Walls / Slab And Making Good The Same. Complete With Painting Of One Coats Of Red Oxide And Two Or More Coats Of Synthetic Enamel Paint Of Requiredshade Complete As Required. ( Pipe To Be Tested @ 10Kgf / Sqcm For 2 Hrs. ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 12 25 Mm Dia 13 32 Mm Dia 14 40Mm Dia 15 50Mm Dia 16 80 Mm Dia 17 100 Mm Dia 18 Supplying And Fixing Of Pn 16 Flanged Y Strainer Fabricated Out Of Cast Iron Body, Ss 304 Strainer With Perforated Screen With 3 Mm. Dia Holesin Existing Ms / Gi Pipe Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 19 100 Mm Dia 20 Supplying And Fixing Of Pn 16 Cast Iron Dual Plate Wafer Type Check Valve / Non Return Valve With Ss / Bronze Flap Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 21 100 Mm Dia 22 Supplying And Fixing Of Pn 1.6Butterfly Valve ( Wafer Type ) With S.G Iron Disc And Confirming To Is:13095 Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 23 100Mmdia 24 Supplying And Fixing Of Pn 16 Brass / Gm Ball Valves With Screwed End, Ss Ball Including Teflon Tape Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 25 25 Mm Dia. 26 Supplying And Fixing Of Ss 304 Single / Double Headed Oblique Pattern Hydrant Landing Valve ( Internal / External ) With 75 / 100 Mm Dia Flanged Inlet & 63 Mm Dia Instantaneous Type Female Outlet Coupling With Cast Iron Wheel Complete With Abs Cap And Chain And All Accessories As Per Is:5290-93 ( Type-A ) In Cluding Matching Flange ( 14 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 27 Single Headed With 75 Mm Dia. Flanged Inlet 28 Supplying & Fixing Ss-304 Short Branch Pipeconforming To Is: 903:93 Fitted With 20Mm ( Nominal Internal Diameter ) Bore Nozzle, For Projecting Water In Form Of Solid Jet. The Branch Shall Have 63Mm Male Instantaneous Inlet, Suitable For Use With 63 Mm Size Fire Fighting Hoses. H.P. Tested To 21 Kgf / Cm² For 2.5 Minutes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 29 Supplying And Fixing Of Flexible Hose Made With 100% Polyester, Black Epdm Internal Rubber Lining With External Coat Of Synthetic Elastomer ( Is:636, Type-A ) 63 Mm Dia, 15 Mtr. Long Rrl Hose Pipe With Instanteneous Type 63 Mm Dia Ss-304Male And Female Couplings ( Is:903 ) Duly Bound And Riveted To Hose Pipes With Copper Rivets And Ss Wire Etc. As Required.Appropriate Test Certificate / Report With Liable Warranty Of Product / Accessories From Oem Shall Be Submitted. 30 Supplying And Fixing First -Aid Fire Hose Reel Drum Wall Mounted Swinging Type With Ms Construction Powder Painted In Post Office Red, Conforming To Is 884-1985 With Upto Date Amendments, Complete With The Following As Required. ( A ) Thermoplastic / Rubber Hose ( B ) 20 Mmdia Ul, Fm Bronze / Ss Nozzle With 5Mm Orifice ( C ) Drum And Brackets For Fixing The Equipments On Wall. ( D ) Connections From Riser With 20 / 25 Mm Dia Brass / Gm Gate Valves With Screwed End And Conforming To Is:778 Class-1Through Forged Steel Screwed Union & M.S. Pipe. Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 31 With 30 M X 20 Mm Thermoplastic Hose As Per Is:12585 Type-2 And Bursting Pressure 42 Kg / Sqcm 32 Providing & Fixing Stainless Steel Pressure Gauge With Dial Of 150 Mm Dia Size And Range 0 To 20 Kg / Sq.Cmwith 3 / 8 Bsp Bottom Entry , Ball Valve , Ss Syphon Tube All Fittings Etc, Dulycalibrated Before Installation In Mks And Fps Units, Accuracy Level + / - 1% Including Making Drilling In Existing Ms Pipeetc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 33 Sitc Of Ul 10Th Edition / En54 / Vds Certified Microprocessor Based Inteligent, Analogue Addressable, Modular, Expandable Networkableloop Fire Alarm Control Panel With Each Loop Capacity Of Min 125 Detectors Per Loop With Total Of 125 Detectors & Devices With Loop Length Up To 1 Km As Per Nfpa 72 Approval. The Panel Shall Be Able To Give Pin Point Location Of Addressable Units Via The Address Code For Each Unit. The Panel Shall Also Be Able To Automatically Switch Off All Control Switches When-Ever Any Alarm Is Triggered. . The Panel Shall Have 230 + 5 % Volts Power Supply, Automatic Battery Charger 24V, Sealed Lead Acid Maintanence Free Battries Sufficient For 24 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During Emergency Condtion. Loop Interface Cards, Communication Module, Lcd / Led Unit To Indicate Fire / Fault Signal Of Individual Unit, Inbuilt Networking Port ( Both Rs485&Ethernet ) , Serial Port For Printer, Two Supervisory Inputs, Two Position Key Switch And Usb Port For Programming.Including The Cost Of All Accessories Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 34 1 - Loop Panel 35 Sitc Of Pressure Switches Ofpressure Range 3 To 15 Bar For Main, Jockey, Terrace Pumpanddiesel Pumps, Etc. As Required ( Control Cable From Pressure Switch To Panel To Be Paid Extra ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 36 Supplying And Fixing Of 750 Mm X 600 Mm X 250 Mm Outdoor Application Fire Hose Cabinet Made Of 1.6 Mm Thick Ms Sheetduly Powder Coated In Red Color Externally And White Internally With 6 Mm Thick Glazeddoors With Expanded Metal 2 Mm Thick Jali Including Necessary Locking Arrangement Suitable To Accommodate 2 Nos 15 Mtr. Long Rrl Hose And 1 No. Branch Pipe On Existing Wall / Angle Iron Frame As Required. ( Cost Of Ms Structure For Mounting Frame Is To Be Paid Extra ) All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 37 Providing And Fixing Of 15 Mm Dia Bronze Quartzoid Bulb Type Sprinkler Headswith Maximum Working Pressure 11.6 Kg / Sqcm And Suitable For 68 Degree Centigrade Rating Standard Response ( Ul Listed ) Chrome Plated Complete In All Respect Of The Following Type. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 38 Pendant / Upright Type 39 Sitc Of Ul 10Th Edition / En54 / Vds Certifiedautomatic Floating Sensitivity Type Analog Addressable Multi Criteria ( Two Optical / Smoke Sensor To Reduce False Alarm ) Detector With Mounting Base & Led Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 40 Sitc Of Ul 10Th Edition / En54 / Vds Certified Addessable Manual Call Point ( Mcp ) With Led / Fire Indication Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 41 Sitc Of Ul 10Th Edition / En54 / Vds Certified Addressable Sounder With Strobe Light, Loop Powered / Direct Powered From Facp With Sound Level 90 Db And Programmablefrom The Panel Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 42 Supplying And Fixing Inlet Breeching Connection Of Ci Body With Gun Metal Male Instantaneous Inlet Couplings With Inbuilt Nrv, Drainage Connection With 50 Mm Brass Gate Valvecomplete With Pvc Blank Cap And Chain As Required For 150Mm Dia Outlet With 1 No. Matching Flange ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Ways. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 43 2 Way 44 Supplying And Drawing Fire Resistant Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation ( Shielded ) Cables Voltage Grade 300 / 500 V As Per Bs / En 50288-7 In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 45 2 X 1.5 Sq.Mm Armoured With Outer Sheath In Red Color 46 Supply & Fixing Of Co2 Type Fire Extinguisher Conforming To Is:15683:2018, Charged With Co2 Gas ( Purity 99.7% Conforming To Is 15222 ) , Powder Coated Internal & External Surface Manganese Steel Isi Marked As Per Is 7285 Cylinder Body , Wheel Type Forged Brass Release Valve Isi Marked As Per Is 3224 With Inbuilt Safety Release Device ( ( Fusible Plug And Rupture Disc Type ) , 1.0 Mtr. Metal Wire Braided Hose Having Minimum Bursting Pressure Of 140 Kgf / Cm2, Horn With Metallic Thread Connection, Qr Code For Product Traceability, Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 47 Capacity 4.5 Kg. 48 Supply & Fixing Of Dry Powder Agent ( As Per Is 4308:2019 ) , Abc Typefire Extinguisher ( Stored Pressure Type ) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 49 4 Kg 50 Supply & Fabrication Steel Structure With Ms Channel / Angle / Joist / Ismb / Sheet Etc. Including Welding, Rivetting, Cutting, Nut & Bolt , One Coat Of Primer & Two Coat Of Enamel Paint Etc. As Requiredcomplete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 51 S&F Following Sizes ( Dia. ) Of Isi Marked ( Is:9537 P - Ii ) Rigid Steel Conduit With Wall Thickness According To Is Specified Along Withisi Marked ( Is:14768 P-Ii 2003 ) Accessories Inrecessed Using Saddles, Clamps, Fasteners, Pvc Bushes, Check Nuts, As Required Includingcutting Jhiris In The Wall And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 52 25 Mm 53 Supply & Fixing Of Ceiling Mounted Ul Listed Clean Agent ( Hfc-236Fa ) , Modular Typefire Extinguisher , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Fixed Bulb With Temerature 68 Deg C, Qr Code For Product Traceability Including Fixing On Ceiling With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 54 5 Kg Capacity
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
50.
Power #10421753 Price Bid
Tender For Renovation Of C/R building, Development Of Yard,Raising Road Level And Other Miscellaneous Civil Works At 33 Kv S/S Rajgarh - 1 PART-A 2 (B-162/14.55)Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 3 1.8E/W in excavation by mechanical means (hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5m in whichor 10 sqm on plan) including dressingof sidesand ramming of bottoms, lift up to 1.5 m, including taking outthe excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 4 (B-54/3.1.6)Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) 5 (B) M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). (3.1.2) 6 RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand) (6.1.6) 7 (B-107/10.16)Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 8 (B-72/6.15)Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 9 (B-65/5.2.2)Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 10 (B-66/5.8.3)Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 11 (B-139/12.3.2)Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:20mm thick. 12 (B-139/12.5)6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 13 (B-139/12.3.1)25 mm thick 14 (B-144/12.37.3)Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) 15 (B-142/12.22.1)Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.(A) New Plastered Surface (three or more coats) 16 (B-144/12.37.1)Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping andpriming coat with cement primer. 17 (B-145/12.42)Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 18 (B-146/12.46.1)Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(A) Two or more coats on new work 19 (B-146/12.46.2)(B) One or more coats on old work. 20 (B-15.29)Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roofslabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. 21 (B-109/10.22)Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 22 (B-56/3.8)Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 23 (B-101/9.19.3)Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) 24 (B-102/9.26)Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 25 (B-102/9.27)Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 26 (B-133/11.26)Random rubble dry stone Kharanja under floor. 27 (B-98/9.5)Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 28 (B-72/6.17.3)Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. 29 (B-100/9.17)Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 30 (B-93/8.13.2.1)Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick .Commercial Veneer both side 31 (B-93/8.14)Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 32 (B-146/12.45.1)Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 33 (B-72/6.18.1)Supplying and fixing stone lintels/bed plates of approvedquarryroughdressedincement mortar 1:4 :Upto 15 cm. thick. 34 (B-152/13.24)Labour charges for repair to door / window with out using any material such as applying randha ( finishing ) tightening of bolts & screw etc 35 (B-150/13.4.1)Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm 36 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 37 9.8.1(A) Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 38 9.2Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 39 (B-104/9.38.3)Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm 40 7.25.1P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size600 mm X 600mm 41 10.33.2Providing & fixing calcium silicate perforated ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:-8 mm thick 42 (B-/9.39)P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge. 43 (B- /8.33)Providing and fixing Almirah lock (50 to 70 mm size )of approved makewithout pair of handles for door with necessary screws etc completeas per direction of Engineer-in-charge. 44 (B- /13.12)Repair to stone masonary in cement sand mortar 1:6 with old and new stone. 45 B-/16.58)Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. 46 13.29/B-153Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried..ii) Applying Epoxy primer on the exposed steel bars. iii) Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush.iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. 47 3.28Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site. 48 (B-86/7.12)Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 49 (B-86/7.13)Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 50 (S-218/1.20.3)P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall:PVC withPVCbend and superior internal fittings as per IS : 7231 . 51 (S-220/1.59)P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 52 (S-/1.65)P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge 53 (S-/2.33.5)Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Two way Bib Cock 15 mm nominal size 54 (S-231/2.6.5)P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make:C.P. Pillar cock, high-neck, 15 mm nominal bore. 55 (S-223/1.43.1)P& F waste Pipe with all fitting P.V.C with C.Pnut 32 mm 56 (S-218/1.14.1)P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. . 57 (S-223/1.45.1)P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm 58 (S-221/1.36.3)P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm 59 (S-224/1.47.8)P & F Towel Rail or Ring of approved quality/make: C.P. Brass Towel Ring revolving type 60 (S-225/1.52.1)P & F Soap Dish or Tray of approved quality / make C.P. brass 61 (S-240/2.38.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 20mm nominal size 62 (S-240/2.38.4)(B) 32mm nominal size 63 (S-240/2.39.2)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).(A) 20 mm nominal size 64 (S-240/2.39.4)(B) 32 mm nominal size 65 (S-233/2.12.1)P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 66 (S-232/2.7.3)P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore. 67 (S-233/2.14.9)P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :Brass / GunmetalHalf-turnwt. 1 Kg.ofapprovedquality / make,25mmnominalbore. 68 (S-233/2.15.1)P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make:Gun metal 15 mm nominal bore 69 (S-233/2.15.3)Gun metal 25 mm nominal bore 70 (S-233/2.13.7)P & F 15 mm. Dia Connection Pipe of approved quality/make :CP Brass Pipe with CP Brass nuts upto length 450mm. 71 (S-236/2.26.3)P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity. 72 (S-232/2.11.2)P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ballcomplete :Brass wt. Not less than 400 gm, 20mm. 73 (S-247/3.16.2)P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.(b)75 mm dia 74 (S-247/3.16.3)(b)110 mm dia 75 (S-244/3.3.1)Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe)100mm dia S.W. pipe 76 (S-248/3.17.9.(ii))P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87.5-110 mm dia 77 (S-249/3.17.12(ii))Vent Cowel 110 mm dia 78 (S-248/3.17.3(ii))Plain Tee110 mm dia 79 (S-249/3.17.15(ii))Pipe Clip 110 mm dia 80 (S-251/3.21.2)Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 450 x 450mm depth upto 0.5 M Cement cover with frame 81 (S-255/3.38.1)Construction of Cement Concrete Chamber 125mm dia.C.P. Brass grating 82 (E-07/3.1.1)Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box , 10 A Modular switch,Modular faceplate with grid plate, 3 pin ceiling rose/holder /3 way Connector,screws,making connections, testing etc. as required. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR Short point (up to 3 mtr.) 83 (E-07/3.1.2)Medium point (up to 6 mtr.) 84 (E-07/3.1.3)Long point(up to 10 mtr..) 85 (E-08/3.3.1)Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surfaceISI marked ( IS:14927 P - II ) virgin materialUPVC Trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ Surface Moulded virgin materialUPVCModular Box,modular 10A switch, 3/5 pin6 Amodular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR:On board 86 (E-9/4.1.7)Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm 87 (E-9/4.1.14)2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 88 (E-8/3.4.2)S&F following sizesof ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm x 12 mm 89 (E-33/7.36)Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 90 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating(E-17/6.1.1.2) 91 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator 63 A Rating (E-18/6.2.1.2) 92 (E-22/6.10.1.2)Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Metaldoor (single phase) IK-09 and IP-43 with Metal end box 6 way(6+2) 93 (E-30/7.26)Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 (E-30/7.21)Providing & Fixing of IS 11037:1984markednon modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 95 (E-81/15.7.3)Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 96 (E-88/17.4.2.2) Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Moutning Minimum lumen output 3600 lm 97 (E-82/15.15.1)Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Wall mounting type with Adjustable Vertical Angle 98 (E-95/18.12.6)Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .LLED Street Light fixture with Minimum lumen output 11225 lm 99 (E-95/18.12.2)LED Street Light fixture with Minimum lumen output 3700 lm 100 (E-96/18.18.3)PProviding & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 32 mm Dia. 101 P & F IS:371 marked6 amp surface type ceiling rose including making connection testing etc. as required.Group2E071400Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.12) 102 P & F ISI marked6 amp bakelite batten/angle holder including making connection testing etc. as required.Group2Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(E-28/7.13) 103 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing (E-87/17.2.2) 104 (E-56/11.2.1.1)Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0sqmm 2core. 105 (E-90/17.9.3)Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 Watt 106 (E-82/15.12.1)Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .300 mm sweep(900/1400 RPM) 107 11.38.3(A)Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc.Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 108 11.39Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. 109 11.40Add extra over rates of item No. 11.38, A to C if colored paver blocks are used 110 7.52Providing and fixing machine pressed cement concrete (M-20) compressed with hydraulic compression machine kerbs or dands of size upto 60cm length as per drawing, jointing with cement mortar (1:3) over 20 mm thick base cement mortar (1:6) & painting the exposed surface with enamel paint of approved brand complete work as per direction of Engineer in charge size 15 cm x 38 cm. 111 17.1Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. 112 9.3.1Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 113 (B-175 /16.1.1.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 114 (B-175 /16.1.2.1)Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 115 (16.10.2)Providing and fixing expanded grill made of aluminum as per designand drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Powder coating aluminum ( minimum thickness of powder coating 50micron) 116 (B-176/16.5.2)Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 117 (B-176 /16.4.1)Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 118 (B-177/16.8)Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 119 (B-177/16.9.3)Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-chargePolyester powder coated minimum thickness 50 micron aluminium . 120 (B-176/16.6.1)Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate 121 (B-95/8.27)Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. 122 (R-19/5.3)Providing, laying, spreading and compacting stone aggregate of as per table 400-10 and 400-11 Wet mix macadam specifications including premixing the material with water to OMC in wet mix plant as per approved design mix, carriage of mixed material by tipper to site laying in uniform layers with motor grader/F.E.Loader/Paver finisher, in sub base/base coarse on a well prepared under base and compacting with vibratory roller to achieve the desired density including lighting, guarding, barricading and maintenance of diversion etc. (MoRTH specifications : Clause 406) by mechanical mean with all lead. 123 14.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
TenderDetail
Loading tenders