View Bid Results For Laboratory Mixing And Stirring Equipment Tenders

We found 12 Bid Results related to laboratory mixing and stirring equipment tenders. You can find Contractor details who won laboratory mixing and stirring equipment tenders along with contract details in Bid awards announcements section.

Filters
Stage
5
4
3
Tender Publishing Platform
1
11
State / UT
7
3
3
2
1
1
1
1
Contract Value
8
3
1
Publish Date
0
0
0
0
0
Sector
7
4
2
2
1
1
1
1
Ownership
3
7
4
1
Within keyword
Active filters:
Showing 1–1 of 12 tenders matching your filters
1.
Road Transport and Highways #10808200 Price Bid
Open Tender Document For E-Procurement Of Laboratory Equipment (Soil, Aggregates, Cement, Reinforcing Bar, Concrete Test Equipment, Water, Geo-Textile And Geogrid) For Material Testing Laboratory Of Iahe Open Tender Document For E-Procurement Of Laboratory Equipment (Soil, Aggregates, Cement, Reinforcing Bar, Concrete Test Equipment, Water, Geo-Textile And Geogrid) For Material Testing Laboratory Of Iahe , Soil , Unconfined Compressive Strength Compression Device With Digital Load Frame: Hydraulic Proving Ring, Dial Gauge Vernier Callipers, Timer, Oven, Weighing Balance , Shear Strength Vane Shear Apparatus , Grain Size Analysis As Per Is:2720 (Part- Iv) Pipette Apparatus (I) Sampling Pipette (Ii) Glass Sedimentation Tubes (Iii) Weighing Bottles (Iv) Deleted (V) Stirring Apparatus (Vi) Sieves -2Mm, 425Umm , 75Umm Is Sieves (Vii) Deleted , Specific Gravity Hydrometer Apparatus: Two 1000 Ml Graduated Cylinders, Dispersing Agent Solution Containing Sodiumhexa-Metaphosphate, Dessicator And Centimetre Scale. , Shrinkage Limit Test Full Set Of Equipments 1.) Evaporating Dish Of Porcelain, 2.) Spatula And Straight Edge, 3.) Balance-Sensitive To 0.01 G Minimum.4.) Shrinkage Dish. Circular, Porcelain Or Non-Corroding Metal Dish, 5.) Glass Cup. 50-55 Mm In Diameter And 25 Mm In Height,6.) Glass Plates. Two, 75X75 Mm One Plate Of Plain Glass And The Other Prongs, 7.) Thermostatically Controlled Oven,8.) Wash Bottle Containing Distilled Water, 9.) Graduate-Glass, With Capacity Of 25 Ml. 10.) Mercury. , Sand Equivalent Value (I) Graduated Cylinder (Ii) Irrigator Tube (Iii) Siphon Assembly (Iv) Weighted Foot Assembly (V) Measuring Can (Vi) Sieve -4.75Mm (Vii) Funnel (Viii) 4- Litre Bottle (Ix) Flat Pan (X) Timing Device (Xi) Sand Equivalent Shaker , Ph Test -Electronic Method (I) Ph Meter (Ii) Digital Balance 300 Gm Capacity-Sensitive 0.001Gm (Iii) 100Ml Glass Beaker -3Nos. (Iv) Volumetric Flask-500Ml -Nos. (V) Wash Bottle-100 Ml (Vi) Mortar With Rubber Covered Pestle , Aggregates , Polished Stone Value (I) Accelerated Polish Machine Mounted On Firm ,Level And Non Resilient Base Of Stone Or Concrete (Ii) Road Wheel (Iii) Means For Rotating Road Wheel (Iv) Means For Bringing The Surface Of A Rubber-Tyred Wheel Of 20 Cm Diameter And 5 Cm Breadth To Bear On The Stone Surface Of The Road Wheel With A Total Load Of 40 Kg. (V) Means To Feed The Sandand Water At A Uniform Rate(Vi ) Means To Feed The Emery Powderand Water At Uniform Rate (Vii) Friction Tester: Is: 2386 Part 4 As Perspecification Of Rrl Uk (Viii) 25 Kg Hard Siliceous Sand (Ix) Emery Powder 5 Kg , Alkali Aggregate Reactivity Mortar Bar Method:Scales, Weights, Sieves, Glass Graduates, Specimen Moulds, Mixing Bowl, Tamper, Trowel, Containers, Length Comparator , Alkali Aggregate Reactivity Chemical Method: 1. Electronic Balance 2. Pulveriser 3. Reaction Container, Reagents, Glassware , Petrographic Examination 1. Geological Hammer 2. Petrographic Microscope 3. Screen Confirming To Is Sieve 4. Digital Balance 5. Portable Handheld Cutting Machine 6. Hand Lens 7. Glass Sides Etc. , Deleterious Material & Organic Impurities Sedimentation Pipette: A Watertight Screw-Topped Glass Jar,1000 Ml Measuring Cylinder, Chemicals, Containers, Sieves , Cement , Soundness (Autoclave Apparatus) Graduated Glass Cylinders, Moulds, Autoclave, Length Comparator , Compaction (Mortar Cube Vibrator) , Fineness (Blaine Air Permeability Apparatus) , Ph Meter ( 2 In Nos.) , Reinforcing Bar (Steel) , Reinforcing Bar (Steel) Universal Testing Machine, To Determine Unit Weight, Yield Strength,, Proof Stress, Ultimate Tensile Strength, % Elongation, Bend And Re-Bend Test , Concrete Test Equipment , Vibrating Table 1Mx1m (Full Set Of Equipments) , Needle Vibrator ( 2 In Nos.) , Permeability , Dry Shrinkage(Shrinkage Apparatus) ( 2 In Nos.) (Full Set Of Equipments) , Air Content (Air Entrainment Meter Apparatus) (Full Set Of Equipments) , Durability (Rapid Chloride Ion Permissibility Apparatus) , Depth Of Penetration (Water Permeability Apparatus) ( 2 In Nos.) (Full Set Of Equipments) , Water , Physical Analysis Of Water , Geo Textile And Geogrid , Pull-Out Resistance Of Geotextile /Geogrid
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
3.
Health and Family Welfare #10184905 Price Bid
Supply Of Lab. Equipment At Govt. Ayurved Collage, Sikar , Khalva Yantra , Small :- Mangecha Black Stone Black Stone , Volume: 2Lt Capacity. Material - Stone, Smooth Mixing And Stroke Movement, Length - 10 Inch. , Medium :- Mangecha Black Stone Size Black Stone , Volume: 4Lt Capacity, Material- Stone Length- 12 Inch , Porcelain :- Porcelain Mortal And Pestle/Kharal Diameter - 6 Inch , Tapta Khalv Yantra :- Pre-Historic Man Thousands Of Years Ago To Grind Grains For Bread And Plants For Medicines. Tapta Khalva Yantra (Hot Mortar And Pestle) Is An Open-Faced Mortar Having Different Sizes And Shapes-Round And Oblong. , Moosha (Crucibles) :- Ceznek Clay Graphite Foundry Crucibles1 - 1 Kg , Koshti With Blower :- Made Of Brics And Cement , Yantra , Dolayantra :- Shodhan Process Of Ras Aushadhi In Which Drug Containing Pottali To Be Suspended Like Pendulum In Particular Liquid Media For Specific Time, Since The Material For Purification Is Kept Swinging In The Liquid In A Pot, This Equipment Is Named As Dola Yantra. , Balukayantra :- Mud Vessel (9 Inch Depth) With Glass Bottle , Pitharayantra :- Made From Sandlid (Mud) , Bhudhara Yantra Etc. :- A Cricible With Id. Sand Fill In A Pit , Distillation Apparatus And Arka Yantra :- Stainless Steel Twin Distillation Appartus Kuppipakwa , Kupipakva Bhatti :- Kuppiakwarasayanfurence, 1 Bottle 1.51Kw-220 Volt Single Phase , Wet Grinder :- Stainless Steal Power 50 Hpmotor,Capacity - 5 Lit. , Mixi :- With Adjustable Speed Anti Skid, Capacity - 3 Lit With Steal Jars , Juice Extractor :- Hand Press Juicer Material - Aluminium Dimensions - 12D X10w X 2H Cm , Sealing Machine :- Voltage- 220Volt, Packaging Type- Manual, Question- 8 Inch, 12 Inch, 16 Inch , Balance (Different Capacities) , Physical :- Sensitivity Drift – 1/5Mg, Weighing Capacity- 1 To 10Kg Hight-15-25Inch , Chemical :- Safranin Stain Solution , Electronic Balance :- Accu Scale (As - 08), Digital Capacity - 50 Kg X 5 G, Pan Size - 12 X12 Digital , Heating Device- , Gas Stove :- Material - Stainless Steel, Barnew - Peetal, Diamension - 31.5 X 30 X 9 Cm With Isi Standard , Hot Plate :- Highly Resistant To Thermal Shack Uniform Heating Temp Range-250*C To 550*C With Iso Certified Company , Chulla (Charcoal) :- Material -Metal, Diamention - 25.9L X 25.9W X 24.4 Cm With Isi Standard , Big Vessels And Containers , Brass :- Easy To Use And Wash.Handmade Pure Brass Water Pot Degchi Handi.3.5 Liter. Use For Daily Kitchen Cooking On Gas Stove For Milk,Vegetables,Etc. , Copper :- Easy To Use And Wash.Handmade Pure Copper Water Pot Degchi Handi.3.5 Liter. Use For Daily Kitchen Cooking On Gas Stove For Milk,Vegetables,Etc. , Steel Etc. :- Easy To Use And Wash.Handmade Pure Steel Water Pot Degchi Handi.3.5 Liter. Use For Daily Kitchen Cooking On Gas Stove For Milk,Vegetables,Etc. , Earthen Vessels-Pots :- Pharmacention , Jars(Porcelain) Fermentation Purpose :- 10Ml Dia - 30 Ml High- , Enamel Trays :- Enamal Tray For General Lab - 8X10 Cm Black Pade Of 1 , Spirit Lamp :- Made Up By Mattle , Measuring Equipments Different Size (Glass) :- 250 Ml With Glass , Pyrometer :- Temperature Range 600 To 2500°C, Analog Output 0-20Ma, 4-20Ma, 0-10V (User Selectable) Operating Temperature, 0°C…….70°C 0°C…..200°C (With Water Cooling Jacket), Power Requirement 12V To 28V Dc/Ac, Weight & Dimensions 600G Dia= Ø 49.5 Mm; Length=118Mm , Thermometer :- Vitszeethermo Meter Temp. -10 To 110*C , Vessels , Frying Pan :- Solimo Steel Heavy Bottom , Steel Vessel :- As One Stacking Stainless Steel Tray L Size , Spatula :- Material Prim Silicom Win Heal Resistantal Handle , Ladle Sand Spoons :- Stainless Steels , Knife :- Stainless Steels , Plates :- Stainless Steels , Samdamsa Yantra(Tongs) :- , Sieves(Assorted Nos. And Size) :- Trade Indiamultimill Slew For Phama , Dravyaguna , Dissecting Microscope :- 20X-40X Magnification, Adjustable Zoom, Incident And Transmitted Light, 3-Year Warranty , Digital Weighing Scale :- Upto 10Gm With Accuracy 0.001 , Digital Weighing Scale :- 10-100Gm With Accuracy 0.001 , Digital Ph Meter (Amazon) :- Accuracy ±0.01 Ph, Automatic Temperature Compensation, 3-Year Warranty , Ostwald Viscometer (Amazon) :- Calibrated, With Cleaning Kit, 3-Year Warranty , Pycnometer Or Specific Gravity Bottle :- Material-Glass, Capacity 50 Ml Bottle Shape-Flat , Rog Vigyan Laboratory , Binocular Microscope :- New Inproved Model With Quadruple Nose Piece Having Positive Click Stops Based On Balls, Binocular Head With Hard Coated Prisms, Co-Axial Focusing Based On 4 Stage Gear Reduction System, Travelling On Ball Guides, Built In Co-Axial Mechnical Stage For Slide Manipulation, Built In Light Arrangement Having 6V-20W Halogen Lamp And Solid State Variable Light Control System With Provision Of Day Light Arrangement Complete As Above In Thermocole Packing With Following Optics. Eye Piecesh5x And Wf10x (Paired) Objectives4x, 10X,40X (Sl), 100X (Sl) Oil Immersion. , X-Ray View Box :-Light Opacity, Controller To Just Your Screen Brightness , Hemoglobinmetter :- Manuual , Dropper :- Made With Plastic, Transparent , Red Cell Pipette :- Red Bead Clearly Visible, Marking 0.5,1,101 , Improved Neubauer Chamber :- Thick Crystal Slide (30×70×4Mm) , Incubator :- Electric, Automatic Turning With Alarm, Life Span- 10 To 15 Yr. , Wintrobe’S Tube :- 110Mm Long With Interval Bore Diameter Of 3Mm , Pasteur’S Pipette :- 5Ml Graduated – 217Mm Length , Westergrens’S Stand :- Plastic Rounded , Ultraviolet Lamp :- Spectrum Of Light Range- 10 To 400Nm , Bp Apparatus :- Mercurytype Sphygmomanometer , Stethoscope :- Deluxe Acoustic Stethoscope , Thermometer :- Digital , Physical Balance :- Sensitivity Drift – 1/5Mg, Weighing Capacity- 1 To 10Kg Hight-15-25Inch , Bunsen Burner :- Precise Heating With Adjustable Flame , Sterile Vessels/Bottle To Collect Samples :- Transparent Glass , Torch :- Made With Stainless Steel, Battery Powered , Knee Hammer :- Stainless Steel 128, 256 And 512 Hz Tuning Fork , Measuring Tape :- Plastic , Ent Examination Set :- Different Size With Stainless Steel , Reflectors(Mirrors) :- Good Quality , Weighing Machine :- Digital , Tuning Forks :- Tylor Model Chrome Plated Handle Knee Hammer , Nasal Speculum :- Length Between- 14.5 To 150Mm , Laryngoscope :- Stainless Steel Blade, Bright, Rechargeable , Catheters :- Length +/-30 Cm, Balloon Capacity, 1.5Lit, Diametere- Ch12 To Ch20 , Probes :- Switchable Between 1× 10 , Ct And Bt Kit :- 90Mm Capillary’S, Uniform Bore , Glucometer :- More Accuracy , Blood Sugar Test Strip:- More Accuracy , Sterile Disposable Lancer/Needle :- Different Sizes , Glass Rod :- No Specification , Syringe Needle Destroyer :- Box Constructed Of Cardboard , Cover Slip :- 10 Gram18x18 Transparent Glass , Cleaned Slides :- Transparent, Unscratched Glass , Litmus Paper :- Good Quality , Ph Indicator Paper Strips :- Urine Ph Test Strips With Other 10 Parameters Including Glucose And Protein , Test Tube :- Transparent, Unscratched Glass With Different Diameters , Separating Funnels Of Various Sizes :- Available With Stopcock, Interchangeable Stopper, Conicle , Glass Jars With Lid Of Different Sizes :- Transparent Glass With Different Sizes , Capillary Tubes :- Transparent Glass , Rubbers Heat :- Anti-Skid, Antistatic Chequered , Magnifying Lens :- Different Sizes , Urinometer:- Air Filled Glass Tube , Centrifuge Machine :- Maintains Free, Brush Less Driver Motor, Capacity 8X1.5- 2Ml, Cooling Capacity- -4 Degree Calcius Max , Tongue Depressor:- Stainless Steel , Stop Watch :- Good Quality With Alarm Function , Multi Stix :- , Test Tube Stand :- Stainless Steel , Ent Equipment’S , Bull’S Eye Lamp With Head Mirror :- 100 Watts Milk White Bulb , Stitch Removal Scissors :- Stainless Steel 410 Grade Stitch Cutting Scissors (Standard Size) Blade And Handle 6 Inch , Revolving Stool (Patient) :- Revolving And Height Adjustable Patient Stool, Made Of High Grade Mild Steel For Long Life. Height Adjustable From 12 To 15 (Approx) Ss Top For Seating , Mouth Mirrors :- Mirror With Handle , Oral Examination Probes :- Stainless Steel , Laryngeal Mirror :- Stainless Steel , Nasopharyngeal Mirror :- Stainless Steel , Cheek Retractor :- For Adult & Child. Made Of Good Quality Plastic , Schiotz Tonometer:- Schiotz Tonometer With 3 Weights Plunger In Plastic Case , Swasthavritta , Digital Weigting Scale :- Conposed Of An Lcd Screen, Load Cell Controller And Platform , Abbe Refractor Meter:- Measuring Range Nd 1.300 To 1.700 Measuring Range Sugar 0 To 95 / Scale-Translucent Glass Digital Temprature Indicater Optional Temp. Range-10 Degree To 100*C , Hot Air Oven :- Temp. Range- 5*C To 250*C, Temp. Accuracy- 0.5*C To 2*C, Construction- Made Up From Stainless Steel, Doors-Double Voalled And Inulated With Mineral Wood, Heating Elemetric- Wet And Dry Heater , Grinder :- Meadium Sized 8000 Rpm , Megnetic Stirrer:- Hot Plate Magnetic Stirrer With Glass Ceramic Hot Plate Capacity 5L, Stirring Speed-1500 Rpm , Hot Plate:- Highly Resistant To Thermal Shack Uniform Heating Temp Range-250*C To 550*C , Digital Ph Meter:- Range Ph- 0 To 14Ph, Temp. Compensation- Manual, Baffer Recognition-Manual And Auto Matic,Display-4 Digit Led Display , Vacume Filter System:- Size-150Ml Law Liguid Reteution Funner Design , Glass Pipette:- 100Ml Capacity , Burettes :- Made Of Glass Or Plastic Standered Size To 50 Ml Of Liguid , Micro Pipettes:- Volume Ranges From 0.1Ml To 100000Ml , Heating Mantles :- Made From Aluminium Stainless Steek Or Glass Fiber Yarn. Temp. Range Up To 400*C, Capacity-500Ml, 1L,2L,3L, Heating Manttes-Kanthal 80:20 Michrone Wire Heating Elements , Agadtantra , Beaker(50Ml) :- Borosilicate Glass With Marking , Test-Tube (10Ml) :- Borosilicate Glass With Marking , Test-Tube Holder :- Aluminium Testtube Holder With Sliding Collaor And Wooden Handle , Gas Or Electrical Burner :- Lab Use Bunsen Burner , Petry Dish :- Borosilicate Glass , Stirer :- Wood Or Metal , Litmus Paper :- Length Of Sheet 53Mm , Speciman Jar :- Airtight And Leakproof Borosilicate Glass With Metal Lid
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
4.
Educational and Research Institute #9426408 Technical Bid
Rate Contract For The Procurement Of Consumables/Non-Consumables For The Department Of Transfusion Medicine , Note:1.*Samples For Kits, Reagents And Consumables Marked With Star (*)/Brochure Listing Product Details/Certificate Certifying Compliance To Specifications Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender. 2. #Samples For Kits, Reagents And Consumables Marked With Star (#), Distributor Authorization Letter From The Manufacturer Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender.3. In Case Of Non-Receipt Of Samplesas Specifed For Above Within One Week After Display Of E-Tender, An E-Mail Remainder (Mentioned In Tender Form) Will Be Sent To Supply The Same. In Case Of Non Receipt Of Sampleswithin One Week Of Reminder The Bidding Will Automatically Stands Canceled. Only Bidders Who Have Provides Samples Will Be Taken For Final Evaluation 4. Selection Will Be Made Only After Evaluation Of Samples/Brochure, Certificate/ Demonstration Etc.Consumables , Anti-A Grouping Sera Igm (Monoclonal)* (10 Ml Vials)Specifications For All Above Antiseras And Bovine Albumin (Item No: 1 To 13) 1. All Antiseras Should Meet Minimum Quality Control Specifications As Per Transfusion Medicine Technical Manual, 2Nd Edition, Pg.No: 346-351; Director General Health Services, Ministry Of Health And Family Welfare, Govt. Of India Publication2. The Manufacturers Should Have Supplied All Above Mentioned Antiseras And Bovine Albumin Continuously And Satisfactorily To Government Blood Banks For A Period Of 5 Years. List Of Such Government Blood Banks Should Be Enclosed. A Satisfactory Quality And Supply Certificate From Any Of The Two Government Blood Banks Should Be Enclosed For Preceeding 3 Years.3. The Quantity Quoted May Be Increased Or Decreased Without Assigning Any Reasons. , Anti-B Grouping Sera Igm (Monoclonal)* (10 Ml Vials) , Anti-Ab Grouping Sera Igm (Monoclonal)* (10 Ml Vials) , Anti-D Grouping Sera Igm (Monoclonal)* (10 Ml Vials) , Anti-A1 (Lectin)* (5 Ml Vials) , Anti-D Igm + Igg Grouping Sera (Monoclonal)* (10 Ml Vials) , Anti-D Igg Grouping Sera (Monoclonal)* (10 Ml Vials) , Anti -D Igg Grouping Sera (Polyclonal)* (5 Ml Vials) , Anti -H (Lectin)* (5 Ml Vials) , Bovine Albumin 22%* (5 Ml Vials) , Anti Human Globulin Sera Igg+C3d (Polyspecifc)* (5 Ml Vials) , Anti Human Globulin Sera Igg (Monospecific)* (10 Ml Vials) , Anti Human Globulin Sera C3d (Monospecific)* (10 Ml Vials) , Instant Abd Blood Grouping Pad/Cards/Strips For Voluntary Blood Donation Camps. (Ready To Use For Blood Grouping Anti-A, Anti-B And Anti-D Igm)* Specifications:1. The Above Pad/Cards/Strips Should Be Approved By Statutory Authority Like Drug Control General Of India/National Inst. Of Biologicals. 2. The Pad/Cards/Stripes Should Contain Wells With Precoated Monoclonal Antisera With Color Coading And Suitable Medium/Matrix To Immobilize Agglutinated Red Cells So As Results Are Read Witin 30-45 Seconds3. The Pad/Cards/Strips Can Be Used At An Ambient Temperature Of 20-40Deg C. 4. It Should Compatible With All Types Of Blood Samples, Namely Whole Blood, Heparin, Finger Prick, Blood Bag Segments Etc.,5. It Should Easily Readable For 24 Hours After Testing,Fully Traceable By Photography/Other Media. 6. Should Be Able To Detect Weak Abd Antigens7. Necessary Dispensing Micro Pipettes/Pasteur Pipettes And Tips Should Be Provided Along With The Kits. 8. Necessary Buffers And Other Consumables Should Be Provided In Enough Quantity Including Wastage If Any For Complete Usage Of All Cards/Pads/Stripes Along With The Kits. 9. The Bidder/Supplier Should Provide Satisfactory Certificates From 3 Blood Banks Which Are Already Using Such Pads/Stripes/Cards.10. Product Should Be Ce Marked11. Expiry After Opening Minimum 14 Days , Copper Sulphate Cuso 4.5H2o - Ar Grade* (500 Gms) , Polygrid Test Tube Stand (For 12 X 100Mm) - 48 Tubes , Stands For Blood Grouping Antisera , Round Adhesive Wound Plaster - Disposable* (100 Nos) , Round Blood Lancets - Disposable And Sterile* (100 Nos) , Disposable Pasteur Pipettes 1 Ml.(500 Nos) , Disposable Pasteur Pipettes 3 Ml.(500 Nos) , Disposable Pasteur Pipettes 10 Ml.(500 Nos) , Blotting Paper (White Ordinary) 60 X 60 Cm* (500 Nos) , Cryo Gloves - Water Proof, Mid Arm, Size-Medium , Tissue Roll* , K3 Edta- Non-Vacuum Tubes 2 Ml* (100 Nos) , K3 Edta- Vacutainer 2 Ml* (100 Nos) , Vacutainer Needle With Holder And With Needle Protector (100 Nos) , Microtip Boxes 2-20 ?L -Autoclavable , Microtip Boxes 2-200 ?L -Autoclavable , Microtip Boxes 200-1000 ?L -Autoclavable , Acrylic Beakers - 50 Ml , Acrylic Beakers - 100 Ml , Acrylic Beakers - 250 Ml , Acrylic Beakers - 500 Ml , Conical Flask - 50 Ml , Conical Flask - 100 Ml , Conical Flask - 250 Ml , Conical Flask - 500 Ml , Conical Flask - 1000 Ml , Thermal Paper For Elisa Reader 110 X 20 (11 Cms Width)* , Pipette Stand (For 6 Pipettes) , Reagent Bottle Stand , Blood Bag/Ffp Storage Racks , Teepol Liquid Cleaner* (10 Litres) , Sodium Hypochlorite Solution 4%* (5 Litres) , Isopropyl Alcohol (500 Ml) , Electronic Thermometer (Wettable)-Range Upto Minus 80 , Surface Temperature Measuring Thermometer , Magnetic Stirrer Bar , Specific Gravity Meter-With Range 1.000 To 1.100 , Nageottes Chamber , Volumetric Flask -500 Ml , Mortar & Pestle , Capillary Tubes (100 Nos) , Ulex Europeus For Lectin Preparation-1Mg , Dolichos Biflorus For Lectin Preparation (1 Mg) , Arachis Hypogea For Lectin Preparation (1 Mg) , Thrombin From Bovine Plasma - Lyophilized Powder (1 Ku) , Protamine Sulfate Reagent (5 Gms.) , Epsilon Amino Caproic Acid-Reagent Grade (1 Gm) , Sodium Dihydrogen Phosphate-Reagent Grade (500 Gms.) , Disodium Hydrogen Phosphate -Reagent Grade (500 Gms.) , Bovine Albumin 6%-Reagent Grade (100 Ml) , Papain Powder-Reagent Grade (100 Gms.) , Ficin Powder-Reagent Grade (100 Gms.) , Phosphate Buffer Saline - Ph 7.4 (100 Ml) , Dithiothreitol (Dtt) (5 Gms.) , Glycine-Reagent Grade -500G , Glycine-Reagent Grade -0.1M , 2- Mercaptoethanol-Reagent Grade (100 Ml) , Chloroquine-Disphosphate-Reagent Grade (25 Gms.) , Wax Sealant (500 Gms.) , 3350 Mw Polythelene Glycol (500 Gms.) , L-Cysteine Hydrocholride Reagent Grade (25 Gms.) , Nacl (Lr) (500 Gms.) , Disodium Edta (500 Gms.) , Tris (Tris Hydroxymethyl) Aminomethane (25 Gms.) , Sodium Barbital-Reagent Grade (25 Gms.) , Ethyl Alcohol-Reagent Grade (500 Ml) , Erythrosin-Reagent Grade (25 Gms.) , Harris Haematoxylin Solution (500 Ml) , Glycerol Lactate (500 Ml) , Turks Solution (250 Ml) , Ph Strips 0.0-6.0 Ph, Resolution: 0.5 Ph Unit (50 Strips) , Ph Strips 6.0-7.7 Ph, Resolution: 0.3-0.4 Ph Unit (50 Strips) , Ph Strips 7.0-14.0 Ph, Resolution: 0.5 Ph Unit (50 Strips) , Ph Buffer Capsules (3 Standard Buffers- Ph 4, Ph 7 & Ph 10)-2 Each , Microtitre Plate U Bottom - 96 Wells (50 Plates) , Test Tubes With Rim (12X100 Mm) (100 Nos) , Test Tubes With Rim (12X75 Mm) (100 Nos) , Capillary Microhematocrit Tubes (2.9) (200 Nos) Specification:1. Size: Length: 75 Mm, Innder Diameter: 1.2 Mm, Wall: 0.2 Mm 2. Capacity: 70 Ul3. Ends Can Be Sealed With Sealing Clay 4. Interior Surface Of Heparinized Tubes Is Evenly Coated With Ammonium Heparin Which Will Not Interfere With Sodium Determination , Sterile Conical Tubes (100 Nos)Specification:1. Capacity: 15 Ml2. Length: 120 Mm 3. Width: 17 Mm 4. Material: Polypropelene5. Dome Top 6. Rcf: 12000 Rpm 7. Storage: -80°C , Sterile Conical Tubes (100 Nos)-50Ml , Sodium Hydroxide Powder (80-100 Mesh) Extrapure (500 Gms.) , Hydro Chloric Acid (500 Ml) , Citric Acid (> 99.5%) (500 Gms) , Potasium Citrate (500 Gms) , Tri-Sodium Citrate Dihydrate (500 Gms) , Sodium Azide (100 Gms) , Bromylin Crude Powder (100 Gms) , Chloroform (500 Ml) , Neutralizing Solution (24 Ml) , Digitonin (1 Gm) , Di-Ethyl Ether (500 Ml) , Ethanol 50%(500 Ml) , Methylene Chloride(500 Ml) , Xylene (500 Ml) , Chymotrypsin(1 Gm) , Vicia Graminea Lectin (Anti-N Lectin)(5 Ml) , Polybrene (5 Gms.) , Pronase (5 Gms.) , Trypsin (100 Gms.) , Di-Butyl Phthalate (500 Ml) , Di-Methyl Phthalate (500 G) , Sucrose (500 Gms.) , Di-Potasium Edta (500 Gms.) , Magnesium Chloride (100 Gms.) , Chromic Chloride (500 Gms.) , Chloramphenicol (5 Gms.) , Dextrose (500 Gms.) , Inosine (500 Gms.) , Neomycin Sulphate (5 Gms.) , Calcium Chloride (500 Gms.) , Sodium Bicarbonate (500 Gms.) , Sodium Carbonate (500 Gms.) , P Nitrophenyl Phosphate (25 Gms.) , Whatmans Filter Paper-100Mm (100 Nos) , Ficoll Hypaque (100 Ml) , Single Channel Variable Pipettes 20 -200 ?L* Technical Specifications For Single Channel Variable Pipettes (Item No: 130 To 132) 1.Extremely Light Pipetting Action By Tension Free Spring Mechanism2.Fully Autoclavable(121°C):Uv Resistant Material, 3.Volume Locking System4.Increments At Least 0.1?1 Fine Adjustment For Pipettes Expect For 100-1000 ?I Volume Pipette Where Increments Can Be Read As 0.5 ?I 5.Suitable For All Brands Of Tips.6.Adjustable For Variable Volume; Fixation Of Adjustable Volumes7.Three Defined Stops(Single Button Operation Preferred)A. Take Up From First Stop,B. Dispensing And Blow Out, C. Tip Ejection 8.Slim Pipette Shaft, 9.Cone For Standard Tips, 10. Safe Cone Filter Lock11. Easy And Safe Tip Ejector Mechanism., 12. Made Of Corrosion Proof Material.13. Accuracy <.98.5%, 14. Precision<. 99.4%, 14. 2 Years Warranty15. Returnable Samples Should Be Provided For Evaluation , Single Channel Variable Pipettes 100 -1000 ?L* , Single Channel Variable Pipettes 5-20 ?L* , Multi Channel Variable Pipettes 30 - 300 ?L*- 8 Channel Technical Specifications (Item No: 133 To 136) 1. Iso 8655 Certified Digital Multichannel Pipettes Of Variable Volume Suitable For All Brands Of Tips. 2. Pipetting Modes: Autodispense, Dispense, Pipetting, Pipetting And Mixing, Manual Pipetting, Sequential Pipetting And Dispensingrangeincrementprecisiontype 5 To 50?L 0.5 Ul2.0 To 0.7%8 Channel5 To 50?L 0.5 Ul2.0 To 0.7%12 Channel 30-300 ?L5 Ul1.5 To 0.3%8 Channel30-300 ?L5 Ul1.5 To 0.3%12 Channel 3.Extremely Light Pipetting Action By Tension Free Spring Mechanism 4. Fully Autoclavable(121°C):Uv Resistant Material 5.Volume Locking System6.Adjustable For Variable Volume;Fixation Of Adjustable Volumes7. Desirable: A History Function, Service Interval Warning, Sequential Tip Ejection8. Should Be Duly Ce Certified Or Approved9. 2 Years Warranty 10. Returnable Samples Should Be Provided For Evaluation , Multi Channel Variable Pipettes 30 - 300 ?L*- 12 Channel , Multi Channel Variable Pipettes 5 - 50 ?L*- 8 Channel , Multi Channel Variable Pipettes 5-50 ?L*- 12 Channel , Pipette Tips 2-20 Ul* (1000 Nos)Description: Used For Accurate Measurement Of Small Volume Fluid Dispensing. Useful For Safety Of Laboratory Personnelspecification: (Item No: 137 To 139)1. Compatible With International Standard Pipettes Attachable By Firm Grip 2. Available In Packs Of 1000 Tips3. Non Sticky In Nature4. Smooth Internal Surface 5. Pipette Should Be Clean, With Patent Tips That Are Sharp And Pointed6. Pink And Blue Transparent In Colour7. Should Not Be Made Of Reused Plastic , Pipette Tips 2-200 Ul* (1000 Nos) , Pipette Tips 200-1000 Ul* (1000 Nos) , Hemocue Cuvettes# (200 Nos) Specification:1. Compattible With Hemocue 301 Instrument+C2372. Should Be Able To Measure The Hb Using Blood From Finger Prickbased On Azide Methohemoglobin Method. , Cuvettes For Plasma Hemoglobin Estimation(100 Nos) Specification: 1. Compattible With Hemocueinstrument 2. Modified Azidemethemoglobin Method , Leishmans Stain Powder (100 Gms.) , Grams Stain Solution Kit , Methanol (5 Litres) , Sponge Ball For Blood Donors , Paper Tumbler For Drinking Milk - Donor Refreshment (100 Nos) , Test Tube - 5Ml With Clot Activator (100 Nos)-Non Vaccum , Test Tube - 5Ml With Clot Activator (100 Nos)-Vacutainer , Glass Slides (100 Nos) , Temperature - Sensitive Indicators (2-6°C) For Monitoring Red Cell Blood Bags , Blood Irradiation Indicator Labels , Autoclave Indicators , Oxygen Mask With All Sizes Venturie Adapter , Re-Breathing Bags - All Sizes , Round Bottom Test Tube (Without Rim: 12X75cm) (100 Nos) , Round Bottom Test Tube (Without Rim: 12X100cm) (100 Nos) , Test Tube Rack Stand For 72 Tubes , Test Tube Rack Standfor 18 Tubes , Vacutainer – 10 Ml Tube Sterile With Acda (100 Nos) , Measuring Cylinder - 250 Ml , Measuring Cylinder - 500 Ml , Measuring Cylinder - 1 Litre , Stainless Steal Forceps - 18 Inch , Storage Vial - 1 Ml (1000 Nos) , Storage Vial - 2 Ml (1000 Nos) , Storage Vial - 3 Ml (1000 Nos) , Storage Vial - 5 Ml (1000 Nos) , Storage Vial - 10 Ml (1000 Nos) , Sterile Microcentrifuge Tubes-0.5Ml (1000 Nos) , Sterile Microcentrifuge Tubes-1.5Ml (1000 Nos) , Papain Cystein Activated -1% W/V , Cell Pack For Hematology Analyser -20 L , Stomatolyser -500Ml , Cell Clean , Plasmalyte( For Cryo Preservation) , Acd Solution- 500 Ml , Autoclave Bags , Coagulation Reagents (Should Be Compatible With Meril Semi Automated Coagulometer-Merilyser) Pt Reagent-10 X 2 Ml , Aptt Reagent-10 X 2 Ml , Factor Viii Assay-3Ml , Fibrinogen- 20 Test , Coagulation Cuvettes-1000 , Calcium Chloride-10Ml , Note:* Item Nos From 184 To 203 - To Be Procure Only After Ascertaining Stock On Hand And Requirement At The Time Of Placement Of Supply Order. General Specification: ( Should Meet Technical Specification As Specified In Minutes Of Technical Specification Committee To Review Specifications Of Blood Bags For The Use In Blood Banks Held On 15-02-2017 Under Ministry Of Health Govt Of India New Delhi)1. Flexible Pre-Sterilized, 2. Pyrogen Free, 3. Non-Toxic, Non-Haemolytic, Biocompatible Material4. No Risk Of Contamination And Air Embolism (Closed System) With All Leak Proof Seals (Disposable Bags)5. Slit On The Both Sides Of The Bags Should Be Enough To Accommodate 5 – 10 Ml Volume Test Tubes6. The Capacity Of The Bag Should Be Enough To Prevent Any Ballooning/Rupture Of The Bag From The Seam When It Is Filled Up With The Requisite Volume Of Blood7. Flexible Non-Kinking, 8. Non-Sticking, 9. Transparent, 10. Leak-Proof, 11. The Tubing Should Have Same Id/Segment Number As That On The Bag12. The Tubes Should Have Multiple Printed Id/Segment Numbers, 13. Side Diversion Pouch, 14. 16 Gauge Ultra-Thin Walled And Straight, 15. Sharp Regular Margins And Beveled Tip22. Cpda-1 (49 Ml I.E. 14 Ml/100 Ml Of Blood) In Collecting Bag, 23. Sagm (100 Ml) In Satellite Bag,24. Clear & Colourless, 25. No Discolouration On Storage At Room Temperature 26. Manufacturer To Supply Anticoagulant Quality Check Certificate, 27. Non-Peal Off, Heat Sealed Labels, 28. Remain Attached Between Room Temperature To -800C With A Transparent Adhesive29. Date Of Manufacturing, Date Of Expiry And Lot Number Must Be Mentioned On Each Bag, 30. The Expiry Date Should Be At Least 2 Years From The Date Of Supply Of Blood Bags To The Institute31. Filled To Normal Capacity Shall Withstand An Acceleration Of 5000G For 30 Min At Temperature 4°C To 24°C Without Becoming Permanently Distorted And Should Withstand Temperature Up To -80°C Without Breakage.32. The Manufacturers Should Have Supplied Blood Bags Continuously And Satisfactorily To Government Blood Banks For A Period Of 5 Years. List Of Such Government Blood Banks Should Be Enclosed. A Satisfactory Quality And Supply Certificate From Any Of The Two Government Blood Banks Should Be Enclosed For Preceeding 3 Years.Blood Bags * Blood Bags With Cpda1 - Single (350 Ml.)* , Blood Bags With Cpda1- Double (350 Ml.)* , Blood Bags With Cpda1- Double (450 Ml.)* , Blood Bags With Cpda1 - Triple (350 Ml.)* , Blood Bags With Cpda1 - Triple (450 Ml.)* , Triple Sagm Blood Bags (450 Ml.)* , Triple Sagm Blood Bags(350 Ml.)* , Transfer Blood Bags (300Ml.)* , Blood Bags (450 Ml.) With Pre Storage Leukocyte Reduction Filters * , Blood Administration Set With Filter* (25 Nos) , Rbc Leukocyte Reduction Filters (Lab Side With Transfer Bag)- 3Rd Generation* , Rbc Leukocyte Reduction Filters (Bed Side)- 3Rd Generation* , Platelet Leukocyte Reduction Filters (Lab Side With Transfer Bag)- 3Rd Generation* , Platelet Leukocyte Reduction Filters (Bed Side)- 3Rd Generation* , Paediatric Blood Bags With Cpda1 (100Ml)* , Blood Bag For Platelet Pooling By Buffy Coat Method With Leukoreduction Filter (4 To 6 Bags) , Platelet Additive Solution (500 Ml) , Penta Blood Bags With Cpda1* , Apheresis Kits For Plateletpheresis , Apheresis Kits For Therapuetic Plasma Exchange , Specifications For All Above Testing Kits From Item No: 204 To 2151. All The Above Mentioned Test Kits Should Be Duly Certified By Statutory Authorities Namely Drug Controller General Of India And Dghs For Use In Blood Banks 2. The Manufacturers Should Have Supplied Test Kits Continuously And Satisfactorily To Government Blood Banks For A Period Of 5 Years. List Of Such Government Blood Banks Should Be Enclosed. A Satisfactory Quality And Supply Certificate From Any Of The Two Government Blood Banks Should Be Enclosed For Preceeding 3 Years.3. 4Th Generation Test Kits Mentioned Above Should Meet Standard Definitions, Parameters As Per Standard Text Books And Duly Certified As 4Th Generation Test Kits By Drug Controller Of India.Testing Kits*Hiv Elisa Test Kits* (96 Tests) , Hiv Elisa 4Th Generation Test Kits* (96 Tests) , Hiv Rapid Test Kits*(50 Tests) , Hcv Elisa Test Kits* (96 Tests) , Hcv Elisa 4Th Generation Test Kits* (96 Tests) , Hcv Rapid Test Kits*(50 Tests) , Hbsag Elisa Test Kits* (96 Tests) , Hbsag Elisa 4Th Generation Test Kits* (96 Tests) , Hbsag Rapid Test Kits Whole Blood/Serum*(50 Tests) , Syphilis Card Test*(100 Tests) -Tpha Method , Vdrl Rpr Test Kits*(100 Tests) , Card Test For Detection Of Pan Malaria (Pf & Pv) Specific Ldh Using Whole Blood * (25 Tests) , Specifications For Gel Card Centrifuge And Incubatorplacement Specificatons (From Item No 216 To 235)1. Thegel Card Centrifuge And Incubatorequipment Should Be Placed And Maintained Free Of Cost Against The Purchase Of Gel Cards Under Contract Agreement For One Year. 2. The Gel Card Centrifuge And Incubator Will Be Placed On The Condition That It Will Be Owned And Maintained By The Firm Entering Into The Contract For Supplying The Entire Immunohematology Items From 194 To 208 3. Equipment To Be Placed In The Premises Of Blood Bank At Jipmer Under A Guarantee For Free Maintenance For The Contract Period.4. Necessary Inspections And Calibration Certificates To Verify The Compliance Of The Placed Equipment For Immunohematology Workup5. Necessary Training Will Have Tobe Given To The Blood Bank Staff Members, If Needed, From Time To Time.6. Supplier Will Place Another Additional Equipment Of The Same Specification And Model Under The Same Terms And Conditions To Cater For Uninterrupted Trouble Free Services. 7. The Supplier Will Give An Undertaking That The Equipment Supplied Is Of The Latest Model And Version Available As On Date Of Entering Into The Contract. 8. The Supplier Should Ensure That Both The Equipments Are Functioning At All Times. In Case Of Failure Of Any One Of The Instruments The Downtime Should Not Be More Than 24 Hours. Only Under Extraordinary Circumstances The Downtime For The Equipment Can Be Increased By A Period, Which Should Not Exceed 72 Hours.9. Suppliers Should Quote For The All Above Items Mentioned Item No From 216 To 235. No Partial Quote Will Be Entertained. If Partial Quote, The Tender For The Above Items Will Be Summarily Rejected. 10. Authorized Distributor Certificate From The Original Manufacturer Should Be Provided.Immunology Kits ( Should Providesamples For Evaluation. Final Selection Will Be Based On The Results Of Such Evalaution. Any Demonstration Or Training Has To Be Provided Before Evaluation)*# Liss Diluent Ii (500 Ml) , Antibody Screening 3 Red Cell Panel-For Column Agglutination Technique (0.8%) , Antibody Screening 3 Red Cell Panel- For Conventional Tube Technique( 3-5% Cells) , Antibody Identification 11 Red Cell Panel For Column Agglutination Technique (0.8%) , Antibody Identification 11 Red Cell Panel- For Conventional Tube Technique( 3-5% Cells) , Antibody Identification 11 Red Cell Panel (Enzyme) For Column Agglutination Technique (0.8%) , Antibody Identitication Extendedred Cell Panel , Red Cell Preserving Solution For Serological Applications , Diluent-I, Modified Bromelin For Blood Grouping And Enzyme Tests (500 Ml) , Red Cell Elution Kits (10 Tests) , Coombs Gel Cardsfor Antibody Screening And Identification-(Igg+C3d)- 6 Tests Per Card , Coombs Gel Cards For Crossmatching(Igg+C3d)-6 Tests Per Card , Coombs Anti Igg Gel Cards-6 Tests Per Card , Abo/D+ Reverse Grouping Gel Cards (24 Tests) , Rh Subgroup +Cw+K Gel Cards (48 Profile) , Dc Screening Gel Cards (12 Profile)-Igg,Igm,Iga,C3d,Ctrl , Dat Igg-Dilution Gel Cards (12 Profile) , Dat Igg1/Igg3 Gel Cards (12 Profile) , Anti Igg1/Igg3/Igg2/Igg4 Dat Card , Nacl Gel Cards--6 Tests Per Card , For Reagents236-284 Igm Will Be Preferred Over Igg Rare Antiserasanti K Card-72Tests , Anti Jka Card-72Tests , Anti Jkb Card-72Tests , Anti Lea Card-72Tests , Anti Leb Card-72Tests , Anti Lua Card-72Tests , Anti Lub Card-72Tests , Anti M Card-72Tests , Anti N Card-72Tests , Anti S Card-72Tests , Anti S (Small) Card-72Tests , Anti Fya Card-72Tests , Anti Fyb Card-72Tests , Coombs Gel Cards For Direct And Indirect Antiglobulin Testing)-6 Tests Per Card , Check Cell , Panocell 16 , Panoscreen 3/4 , Gamma Elu Kit Ii , Gamma Ega Kit , Gamma Lectin System , Gamma Quin , Freeze Dried Papain , R.E.St. , W.A.R.M. , Gamma Peg , Anti-Ina , Anti Inb , Anti-Mia , Anti Mib , Anti K Igm (1-5Ml) , Anti C Igm (1-5Ml) , Anti C (Small C) Igm (1-5Ml) , Anti E Igm (1-5Ml) , Anti E (Small E) Igm (1-5Ml) , Anti K (Small K) Igm (1-5Ml) , Anti Fya(1-2Ml) , Anti Fyb(1-2Ml) , Anti Jka(1-2 Ml) , Anti Jkb (1-2 Ml) , Anti M (1-2 Ml) , Anti N (1-2Ml) , Anti S (1-2Ml) , Anti S (Small S) (1-2 Ml) , Anti Lea (1-2 Ml) , Anti Leb (1-2 Ml) , Anti Lua (1-2Ml) , Anti Lub (1-2Ml) , Anti P (1-2 Ml) , Anti I(1-2 Ml) , Blood Bags For Total Automated Blood Component Extraction* See Also Above As For Blood Bags Specificationsnote:1. Samples/Brochure Listing Product Details/Certificate Certifying Compliance To Specifications Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender.2. In Case Of Non-Receipt Of Samples Within One Week After Display Of E-Tender, An E-Mail Remainder (Mentioned In Tender Form) Will Be Sent To Supply The Same. In Case Of Non Receipt Of Sampleswithin One Week Of Reminder The Bidding Will Automatically Stands Canceled.3. Selection Will Be Made After Evaluation Of Samples/Brochure, Certificatetop And Bottom Quadra And Penta Blood Bags For Totally Automated Component Extraction.*- 350Ml (For Specification Refer Tender Document) , Top And Bottom Quadra And Penta Blood Bags For Totally Automated Component Extraction.*- 450Ml (For Specification Refer Tender Document) , Molecular Typing Reagents Dna Blood Extraction Kit , Primer (500 Ml) , Ssp Kits For Abo Type , Ssp Kits For Rh Type , Ssp Kits For Abo Type- Variant , Ssp Kits For Rh-Partial D , Ssp Kits For Weak D , Ssp Kits For Kkd Type , Ssp Kits For Mns Type , Ssp Kits For Minor Blood Group Type , Ssp Kits For Hpatype , Ssp Kits For Hna Type , Tbe Buffer-1L , Ethidium Bromide , Ethanol-70% , Microtips- 20 To 200 Microlitre (1000 Nos) , Microtips -1Ml-500Ml , Agarose Powder , Bromophenol Blue , Acrylamide , Ammonium Persulphate , Sodium Dodecyl Sulphate-10% , Ammonium Chloride , Ammonium Bicarbonate , Protininase K , Boric Acid , Consumables For Chemiluminscence Systemnote: 1. Samples/Brochure Listing Product Details/Certificate Certifying Compliance To Specifications Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender.2. In Case Of Non-Receipt Of Samples Within One Week After Display Of E-Tender, An E-Mail Remainder (Mentioned In Tender Form) Will Be Sent To Supply The Same. In Case Of Non Receipt Of Sampleswithin One Week Of Reminder The Bidding Will Automatically Stands Canceled. 3. Selection Will Be Made After Evaluation Of Samples/Brochure, Certificatetesting Kits For Fully Automated Immunoassay System – Chemiluminscence, Floor Model Hiv – Fourth Generation Kit With Fourth Generation Controls, Calibrators From Same Manufacturer. (Who P24ag Int Std90/636) < 0.90Iu/Ml) (100 Tests) (For Specification Refer Tender Document) , Hbsag - Capable Of Qualitative Detection Of Hepatitis B Surface Antigen (Hbsag) With Excellent Mutant Detection. (100 Tests) (For Specification Refer Tender Document) , Hcv - Capable Of Qualitative Detection Of Antibody To Hepatitis C Virus (Anti-Hcv). (100 Tests) (For Specification Refer Tender Document) , Syphilis - The Assay Should Be Able To Detect Treponema Pallidum Specific Antibodies Of Both Igm And Igg (100 Tests) (For Spec Please Refer Tender Document) , Equipments , Water Bath-Laboratory Rangespecifications:1. Dimensions (External) 40 Cm X 40 Cm X 20Hcm (Approx.) 2. Dimensions (Internal) 30 Cm X 30 Cm X 15Hcm (Approx.) 3. Double Wall Insulated Metal Body, 4. Temperature Range 37ºc -100ºc, 5. Digital Temperature Control And Display6. Temperature Precision 0.1ºc, 7. Should Have Provision To Maintain Uniformity Of Temperature8. Should Have The Provision To Incubate Racks Of All Size Of Test Tubes, 9. Illuminated On Switch, 10. Indicator Light Showing Heating Element Operation, 11. Temperature Control 12. Demonstration Of Performance Of Equipment Is Compulsory In Nearby Area Failing To Which Will Lead To Disqualification., 13. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision 14. Should Be Bis/Ce/Fda Approved Product, 15. Warranty-02 Yrs. , Blood Transportation Box Specification: 1. Extended Cold Life, 2. Fixed Two Temperatures Setting Adjustable To +4°C And +22°C. 3. Capacity To Accommodate Minimum 48 Blood Bags Of 450 Ml.C33, 4. External Dimension Of Each Transportation Box Should Be Within 1000 -1500Mm (L)X 800-1000 Mm (W)X 600- 700 Mm (H)5. Chest / Vertical Cabinet With Built In Handles And Hinged Door., 6. Body Material Should Be Polyethylene (Corrosion Free)7. Smooth Castors With Stabilizers For Flexibility And Movement., 8. Ambient Working Temperature -2°C To +43°C, 9. Main Power Switch.10. Microprocessor Based Temperature Controller With Integrated Audio Visual Temperature Alarm Function On Digital Monitoring Display. 11 .Separate Selector Switch For + 4°C And +22°C Temperature Settings., 12. Nominal Dc Power 12 / 24 Volt And Nominal Ac Power 100 – 240 Volt, 50/60Hz. 13. Automatic Ac / Dc Power Supply Selection., 14. Automatic Cooling / Heating Operation., 15. Air Cooled Hermetically Sealed Dc Compressor., 16. Vehicle Fixation Kit.17. Controlled Fan Cooling System For Constant Air/Temperature Distribution., 18. For Storage Of Blood Bags, Minimum Two (2) Wire Basket Should Be Provided In Each Box.19. Power Alarm Audio And Visual By Led. Audio Alarm Can Be Switched Off. Temperature Audio And Visual High And Low Alarm By Led.20 .Minimum Polyurethane Insulation Cfc Free For The Cabinet And The Door., 21. Warranty-02 Yrs. , Binocular Microscope (Without D.G) Specification: 1. Head:Binocular 30° Inclined And Rotatable 360° 2. Eyepieces:10X 20Mm Fov 3. Nosepiece:Reversed, Quadruple 4. Objectives:Plan Achromat 4X, 10X, 40X, 100X Oil5. Condenser:1.25 N.A. 6. Stage:Rackless Mechanical Stage 7. Focusing:Coaxial Coarse/Fine Focus System With Limit Stopper And Torque Adjustment 8.Focusing:Coaxial Focusing System With An Adjustable Tension Control And Upper Limit Stop To Prevent Accidental Damage To Slides; All Metal Gears, Brass Fine Focus Gear 9. Illumination:Led Illumination Variable With Cord Holder 10. Warranty: 5 Years , Table Top Centrifugespecification: 1. Speed Max : 100-6000 Rpm, Rcf: 5030Xg, 2. Automatic Rotor Identification.3. Heavy Duty Brushless Induction Motor For Low Vibration And Noise < 65 Db, 4. Presetting Of Speed And Time And 0-99 Minutes Digital Timer5. Safety Lid Interlock, 6. Digital Speed Indication, 7. Digital Indicator Cum Controller, 8. Dynamic Break And Imbalance Detector With Cutoff 9. Angle Head Rotor With 24 X (5-15Ml Tubes) With Appropriate Tube Adapters Should Achieve Rpm 4500 Or More & Rcf 3300 G Or More 10. Rust Proof Stainless Steel Inner Chamber, 11. To Work On 220 Volts Ac, 50 Cycles12. To Be Supplied With Suitable Servo Controlled Stabilizer, 13. Manufacturer Should Be Iso 13485 Certified., 14. Warranty - 2 Years , Rh View Boxspecification: 1. Built-In Temperature Indicator For Easy, Accurate Monitoring Of Viewing Area. Viewing Area Temperature Adjusts Easily To Compensate For Ambient 2. Temperature Changes. (Range: 45°C To 50°C) 3. Rh Slides Reaches Temperature Of 37°C To 39°C In Two Minutes, Eliminating Wasted Heat Up Time. 4. Soft, Fluorescent, Glare Free Light Provide Uniform Illumination Of Slide Contents. 5. View Box Can Be Gently Rocked Using Large Knob On Support Cradle. 6. Sturdly, Easy-To-Clean Metallic Powder Compact Case. Utilizes Minimal Bench Space. 7. Meets Rh Slide Test Standard Set By The Aabb., 8. Unit Conveniently Includes Three-Wire Cord And Plug. 9. Light - Fluorescent Glare Free, 10. Temp Display - 37°C ± 2°C11. Power - 220 V - 50Hz, 12. Warranty - 2 Years , Specific Gravity Meter Specification: 1. Should Read Specific Gravity From 1.000 To 1.140?2. Hydrometer Should Have A Solid Shot-Weighted Float And An Extra Long Stem For Grasping3. Jar Should Be 5 In. (13Cm) High With Extra Wide Base 4. Warranty - 2 Years , Digital Specific Gravity Meter Specification: 1. Should Read Specific Gravity From 1.000 To 1.100?2. Digital Display3. Warranty - 2 Years , Hot Air Oven - Laboratory Usespecification:Operational Requirementsmicroprocessor Based System With Pid-Temperature Controller With Integrated .Auto Diagnostic System With Fault Indicator.Technical Specifications1. External: Stainless Steel Casing :Insulated Stainless Steel Door With Locking And Rear Zincplated Steel 2.Interior - Internal Volume More Than 200 Liters Easy-To-Clean Interior, Made Of Stainless Steel,With Supports On The Three Sides For Three Adjustable Perforated Stainless Steel Shelves 3. Forced Air Circulation By Quiet Air Turbine/Fan To Ensure Uniform Temperature 4.Fitted With Load Indicator And Safety Thermostat Take Over Indicator Lamp. Lcd/Led Indicator5. Temperature Variation +/- 1 Deg C., 6. Temperature Range- Ambient To 250 Deg C., 7. Output Available For Data Acquisition. Environmental Factors: 1. The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0 -50Deg C 2. The Unit Shall Be Capable Of Operating Continuously In Ambient Temperature Of 10 -40Deg C And Relative Humidity Of 15-90%3. Warranty - 2 Years , Agglutination Viewers For Blood Bank Specification: 1. Designed For Use In Blood Typing, Cross Matching, Antigen Typing, Titers And Other Agglutinations Tests 2. Illuminates Test Tube Contents Through The Use Of A 5-Watt Bulb From Above And A Magnifying Mirror From Below3. Easy To Use Side-Mounted On/Off Switch 4. Flexible Neck Allows For Easy Manipulation Of Light Source 5. Input: 120V 60 Hz, 18W; Output: 12Vac 500Ma6. Warranty: 2 Years , Cold Chain Boxes (4 Pack Vaccine Carriers) To Transport Blood To Wards (Blue - 150 Nos, Pink-150- Nos, Yellow - 100 Nos, White-100 Nos)Specification: 1. Storage Capacity: 1.63 Litres2. Lid Type And Fixings: Removable 3. External Surface Material: Hdpc4. Internal Lining Material: Hips5. Insulation Material: Cfc-Free Polyurrethane 6. Insulation Thickness: 35-38 Mm7. Number Of Ice Packs: 4 X 0.4 Litres 8. Cold Life Without Opening , Tested By Who Approved Laboratory: 4 Hours At 6°C 9. Warranty: 2 Years , Vdrl Shakerspecification: 1. Platform Size 12” X 12” For Keeping Reaction Trays.2. Timer With 0 To 30 Minutes For Control Of Shaking Duration With 1 Minute Interval.3. Should Have Built In Speed Regulator With Maximum Speed Of 150-180 Rpm. 4. Warranty: 2 Years , Plasma Thawing Bathspecification: 1.Unit Should Thaw Atleast 8 Plasma Units In Less Than 20 Minutes. 2.Digital Electronic Bench Top System With Led Display. 3.Should Have 2 Separate Basket Asemblies Securely Holding Plasma Bags4.Water Bath Based Operating System At A Preset And Precise Temperature Of 37°C ± 0.5°C5.Should Give An Alarm When The Plasma Bags Are Thawed. 6. Provision For Programmable Time Setting For Length Of Thawing With Audio Completion Signal.7. Should Have Audio Visual Over-Temperature Alarm System8. Should Have A System To Drain The Chamber. 9. Should Have A Deep Thawing Chamber With A Stirrer10. Warranty: 2 Years , Blood Bag Digital Weighing Balance - Double Pan Specification: 1. Should Be An Electronic Differential Scale. 2. Weight Measurement - 0-2500 Grams (Range) 3. For Weighing 2 Blood Bags Simultaneously For Balancing For Centrifugation Purposes & Should Display The Difference Of Two Loads.4. Maximum Weight Difference - 2500 Grams, 5. Weight Sensors - Load Cells 6. Weight Display Panel - 4-Digit Led Display, 7. Weight Calibration Tolerance - +/-1 Gram 8. Decimal Truncation Error - 1 Gram, 9. Total Accuracy Of Display - +/-2 Grams 10. Weight Accuracy - 4 Grams, 11. 18V Dc (A/C Power Adapter 100-120/220-240 V A/C In) 12. Power Consumption - 5 Watts, 13. Warranty - 2 Years , Blood Bag Digital Weighing Balance - Single Panspecification: 1. Should Have A Microprocessor Based Single Pan Analytical Balance With High Accurary And Precision Is Required 2. Should Have Weigh Accuracy Of Upto Iii Decimal Place, 3. Should Have A Auto-Self Calibration Facility4. Should Have A Auto Zero Setting., 5. Shoud Have One Touch Calibrationj.6. Should Have Weighing Capacity Upto 500 Gm, 7. Should Have A Readability And Repeatability 0.001/G 8. Should Have Stabilization Time <5 Secs., 9. Should Have Lcd Display For Showing Weight. 10. Power Input To Be 220 V To 240 V. Ac, 50 Hz 11. Should Provide With Suitable Ups With Maintenance Free Batteries For Minimum One Hour Back Up, 12. Warranty: 2 Years , Hemocue Testing Systemspecification: 1. Should Be Able To Measure The Hb Using Blood From Finger Prick (Should Be Based On Azide Methohemoglobin Method).2. Should Be Capable Of Displaying Results Within 1 Minute, 3. Accuracy ± 1 %4. Disposable Cuvettes. Cost Of Consumables To Be Quoted Along With This Tender As It Will Be Considered For Financial Comparison., 5. Should Be Portable And Should Have The Battery Backup For 8 Hours Or More With Provision Of Electric Operations .6. Factory Calibrated And Calibration Should Be Verified Automatically Time When The Instrument Is Turned On., 7. Should Have The Memory To Store At Least 500 Results With Date And Time And Should Be Able To Transfer The Results To Pc.8. Should Be Us Fda Or European Ce Class-2A Or Bis, 9. Should Be Iso 13485 Approved Product., 10. Original Literature Of Equipment Should Be Submitted., 11. Warranty: 2 Years , Table Top Incubatorspecification: 1. The Incubator Should Be Suitable For Incubation Of Elisa Plates Of Tti Markers, 2. Dimensions Should Be Approximately 355 X 355 X 355 Mm3. Should Be Sturdy, Double Walled Construction With Complete Inner Chamber Made Of Anodized Aluminum Or Highly Polished Stainless Steel. 4. Gap Between The Walls Should Be Filled With Special Grade Insulation Material For Proper Insulation And To Avoid Heat Losses. 5. Should Have Inner Chamber Fabricated With Ribs For Adjusting Shelves To Convenient Height., 6. Should Be Supplied With 2 Or 3 Removable Shelves. 7. Heating Element Should Be Placed At The Bottom And Side Ribs For Uniform Temperature All Over The Space.8. Should Have The Temperature Control By Thermostat From 20ºc Above Ambient To 50ºc ±0.5ºc. Temperature Control Knob Should Be Graduated In Degrees Centigrade. 9. Should Be Provided With Air Ventilators Port On Sides At Top For Ventilate Fumes & To Assist Convection Process. 10. The Equipment Should Be Provided With A Panel Having A Thermostat Control Knob, On/Off Switch And Indicator Light. 11. Firm Should Also Provide The Relevant Temperature Calibration Certificate For The Equipment From Any Nabl Accredited Lab., 17. Warranty: 2 Years , Domestic Refrigerator Specification: 1. Capacity: 300 Ltrs ( Double Door)2. Material: Stainlees Steel Puf3. Interior Light4. Reversible Door Opening 5. Condensation Drain 6. Voltage: 220 V 7. Warranty: 2 Years , Bp Apparatus Self Check Dial Arm Type Sphygmomanometerspecification: 1. Should Be Aneroid Type, 2. Should Have Isi Mark., 3. Should Have A Measuring Range From 0 To 300 Mmhg 4. Should Be Provided With Adult Arm Cuffs Of Size Medium & Large And Paediatric Cuff. 5. The Dial Mano Meter Markings And Graduations Should Be Permanent And Clearly Visible And Filled With Pigments, With Diameter Of Minimum Diameter Of 160 Mm 6. Body & Bazel – Aluminium Die Casted (Powder Coated), Screw Type Bazel, 7. Sensing-Corrogated Phosphorous Bronze Twin Capsule Bellows., 8. Movement Mechanism – Brass, 9. Connection : Brass, Nickel Plated For 3-4 Mm Rubber Hose 10. Dial – Aluminium, 11. Pointer – White Coated, Thin & Sharp Made Of Phosphorous Bronze, 12. Window Lenses – Clear Plastic. 13. All Plastic Parts, If Any Used Should Not Crack, Flake, Peel Or Disintegrate In Normal Use., 14. The Inflating Rubber Bag Should Be Capable Of Withstanding An Internal Pressure Of 450 Mmhg Without Leaking.15. The Inflating Bulb Should Be Soft And Should Not Have Any Joints Or Ridges., 16. The Fastening Arrangements Of The Cuff Should Be Of Hook And Loop Type (Velcro) 17. The Threading And Fastening Arrangement Of The Cuff Should Show No Sign Of Slip Or Failure When Subjected To The Maximum Test Conditions.18. The Rubber Tubes Used Should Have An Internal Diameter Of 3 ± 0.5Mm And The External Diameter Should Not Be Less Than 8Mm., 19. The Tubes Should Be Fitted With Male And Female Leur Connectors.20 .Should Provide A Carry Bag To Keep The Whole System Safe And Sound. All Parts Should Be Replaceable In Case Of Breakage., 21. Warranty: 2 Years , Insecticutors Description: Insecticutors Are Required In Bleeding Area, Donors Screening Area, Issue Section For Controlling Flies And Other Insects Which May Contaminate Blood Components. Specification: 1. Powder Coated Body For Long Lasting & Durability2. Phillips Uv Tubes 3. Copper Wiring And Copper Choke For Electricity Saving4. Rugged 3 Kv Transformer 5. Zinc Coated Grid To Prevent Rusting 6. Collection Tray For Killed Flies7. Pvc Coated Guard To Avoid Shock8. Low Power Consumption 9. Warranty: 2 Years , Hot And Cold Water Dispenser For Drinking Purposedescription: Provides Safe Drinking Water For Blood Donors 1) Provides Cool Drinking Water At Blood Donation Camps 2) Decreases Chances Of Vasovagal Blood Donor Reactions. 3) Positively Enhances Donor Reaction Affecting Donor Retention. Specification: 1. Quiet Operation, Runs On Electricity And Easy To Clean., 2. Anti Corrosive And No Costly Maintenance3. Plain / Hot / Cold Water Option Available, 4. Compact Design Taking Very Less Space.5. Long Lasting Plastic Front Panel And Faucets, 6. Convenient Removable Drip Tray 7. Led’S To Indicate Primary Function, 8. Low Power Consumption 9. Bimetal Sensors To Ensure Overheating Protection, 10. Weight Less Than 20 Kg, Compact And Mobile 11. Spill Proof Bottle Holder - Optional, 12. Warranty: 2 Years , Vein Illumination Device Description:It Is Used To Visualize Subcutaneous Veins By The Phlebotomist. Useful For A) Prevent Deferrals Because Of Poor Venous Access B) Preventing Loss Of Unit Because Of Inefficient / Insufficient Collection C) Useful For Training Phlebotomist And Building Their Confidence D) Enhances Donor Experience E) Decreases Chances Of Apheresis Procedure Failure F) Non Contact Venous Assessment For Phlebotomyspecification: 1. Based On Infra Red Technology, 2. Clearly Displays Subcutaneous Vasculature Without Any Contact With Skin3. No Need For Calibration Or Adjustments, 4. Includes Charging Cradle And Power Supply Cord 5. Run Time Of At Least Two Hours Per Charge, 6. More Than 300 Vasculature Visualizations Per Charge7. Accessories Available Like: 1) Stand For Hands Free Operation With And Without Charger 2) Clamps For Fixing For Hands Free Operation 3) Mobile Hands Free Operation 6) Padded Carry Case With Shoulder Sling 4) Belt Carry Case., 8. Warranty: 2 Years , Microplate Shaker Specification:1. Platform Size 12” X 12” For Keeping Reaction Trays.2. 4 Number Of Microplates Can Be Kept At A Time3. Timer With 0 To 30 Minutes For Control Of Shaking Duration With 1 Minute Interval.4. Should Have Built In Speed Regulator With Maximum Speed Of 150-180 Rpm. 5. Warranty: 2 Years , Vacuum Cleaner (Hand Held) Specification:1. Special Features: 2 Tier Radial Cyclones, Direct-Drive Motor, Washable Pre-Motor Filter 2. Cleaning Method: Dry 3. Cleaner Type: Handheld 4. Included Tools: Combination Nozzle, Extension Hose, Futon Tool, Gap Nozzle, Mini Motorized Tool 5. Warranty: 2 Years , Phlebotomy Mannequinspecification:1. Advanced Venipuncture And Injection Arm - White Which Gives Complete Venous Access For Phlebotomy As Well As Iv Therapy, Plus Sites For Intra-Dermal And Intramuscular Injections.2. Injectable Metacarpal, 3. Digital And Thumb Veins4. Median Cephalic, 5. Median Basilic 6. Median Cubital Veins, 7. Basilic 8. Cephalic, 9. Accessory Cephalic10. Median Antibacterial Veins, 11. Deltoid Muscle, 12 .Warranty: 1 Year , Microplate Centrifuge Specification:1. Speed: 300-3000 Rpm With Increment Of 10 Rpm, 2. Max Rcf: 2000 X G Or More, 3. Automatic Rotor Recognition And Imbalance Detection. 4. Manufacturer Should Provide Compatible Set Of Microplates With Specifications Of The Same., 5. Timer: 0 To 60 Mins. Continuous Operation 6. Drive System: Brush Less Induction Drive, 7. Noise Level At Max Speed Should Be Less Than 60Db 8. System Should Have Safety Features Like Lid Lock And Interlock9. System Should Have Microprocessor Controlled Pre-Selection And Display Of Speed And Time.10. Manufacturer Should Be Iso 13485 Certified., 11. The Centrifuge Should Be Provided With The Following Accessories 12. Speed: 300-4000 Rpm Or More, 13. Rcf: 2000X G Or More 14. Capacity: Should Be Able To Centrifuge 2 Microplate Of 96 Wells 15. Rotor Head Should Be Available With The Firm For Immediate Replacement, 16. Warranty: 2 Years , Cryoprecipitatebath Specification:The Cryo Bath Is Designed For Rapid And Uniform Thawing Of Fresh Frozen Plasma Bags At 4 ºc +/- 0.2 ºc Such That The Cryoprecipitate Remains Solid, And A Cryosupernatant Liquid Is Formed That Can Be Transferred Out Of The Bag In Order To Manufacture Cryoprecipitate Units.Ii Operational Requirements: 1. Floor Standing System, Mounted On Lockable Castors. 2. Should Be Having Capacity Of 12-18 Bags Per Run For One Cycle. 3. Should Be Able To Thaw Ten To Twelve Plasma Units (Ffp ~200-300 Ml) At A Time. 4. Should Have Stainless Steel Tank Of 22G, And An Insulated Lid Covered With 20G Stainless Steel, 5. Should Be Fitted With Compartments That Have Removable Rack/Tray System For Securely Holding The Plasma Bags And Ensuring That Entry Ports Are Not Contaminated With Water.6. Should Be A Microprocessor Controlled Water Bath Based System Operating At A Temperature At 4 ºc +/- 0.2 ºc Or Alternative Can Also Be Safely Set At 37 ºc +/- 0.2 ºc.7. Digital, Electronic System With Provision For Programmable Temperature Adjustment Setting With Led Display With Temperature Resolution Of 0.1 ºc, 8. Should Not Take More Than 2 Hours At Full Loads To Thaw The Plasma Into Cryosupernatant. 9. Should Have A Deep Thawing Chamber With A Stirrer For Water Circulation & Gentle Rocking For Uniform Heating By High Capacity Pump, 10. Should Have A System To Drain The Chamber Without Lifting Or Tilting, And Should Be Fitted With A Shut Off Valve.11. The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0 -50Deg C And Relative Humidity Of 15-90% Without Getting Rusted. 12. Compatible With Input Voltage: 240V 50 Hz Single Phase Ac14. Should Have An Integrated Voltage Stabilizer Or External Servo Stabilizer Of Appropriate Ratings Meeting Isi Specifications (Input 160-260 V And Output 220-240 V And 50 Hz). 15. Resettable Overcurrent Breaker Shall Be Fitted For Protection, 16. Warranty: 2 Years , Blood Collection Monitorspecification:1. The System Is Used To Collect Donated Blood From The Donor At The Same Time Mixing The Blood For Quality Collection Of Blood.2. Pre-Selection Of Volume To Be Collected. Tarring Of Bag Volume Before Collection. Tarring Range: 0 – 600 G. Automatic Storage And Recall Of Set Volume. Measure Volume With Best Accuracy 3. Led Indication On Commencement Of Collection., 4. Led Indication And Audible Alarm At The End Of Collection., 5. Indication Of Time Taken For Collection.6. Indication Of Blood Flow With Audio Alarm When Blood Flow Is Higher Or Lower Than Desired. Continuous Display Of Collected Volume, Flow And Time During Collection7. Automatic Clamping At Termination Of Preset Volume Collection, 8. Automatic Release Of Bag When Lifted., 9. Continuous Agitation Of Blood Bags During Collection: 12 – 16 Rpm., 10. Easy Provision To Change Preset Volume. 11. Should Operate On Mains As Well As Rechargeable Battery. On Battery It Should Operate For A Minimum Of 5-8 Hours., 12. Should Be Less Than 5 Kg 13. “ Pause Facility” To Pause The Collection. 14. Optional- Memory To Store Donation Data Such As Donor Number, Name Of Operator, Volume Collected, 15. Should Measure Volume With Accuracy Less Than 1 %16. The Unit Shall Be Capable Of Operating Continuously In Ambient Temperature Of 10 - 400 C And Relative Humidity Of 15-90%, 17. Power Input To Be 220-240V Ac, 50Hz As Appropriate Fitted With Indian Plug18. Should Be Technologically Advanced With Modern Blood Collection Scale And Mixer. It Should Be Light Weight & Portable., 19. Warranty: 2 Years , Gelcard Incubator Specification:1. Dedicated To Centrifuge Usa Fda Approved, Sephadex Gel Micro Typing System Cards Based On Column Agglutination “Gel Technology”.2. Usa Fda Approved, Sephadex Gel Micro Typing System Cards Based On Column Agglutination “Gel Technology”. 3. Incubator Should Have The Capacity To Incubate The Gel Card And Test Tubes For 37° 4. Automatic Balance Control 5. Warranty: 2 Years , Gelcard Centrifugespecification:1. Dedicated To Centrifuge Usa Fda Approved, Sephadex Gel Micro Typing System Cards Based On Column Agglutination “Gel Technology”. 2. Centrifuge Should Have Option To Run Gel Card And Test Tubes, 3. Silent Centrifuge For Holding 24 Cards. Each Card With 6 Micro Wells 4. Automatic Balance Control, 5. Centrifugation Time: 10 Minutes Or Less 6. Speed, Time And Functions Are Digital Display, 7. Typing System Cards With ‘V” Shaped Bottom For Clarity In Results. 8. Monitored By Microprocessor., 9. Suitable Rpm.10. Gel Cards Should Be Made Available For Abo& Rh Grouping, Rare Blood Group Antigens, Coombs Test, Pnh, Partial D Typing And Etc., 11. The Price Of The Card Should Be Frozen For A Minimum Period Of Three Years12. 110V-240V/50Hz- 120Hz., 13. Bis/Ec Conformity.11. The Price Of The Card Should Be Frozen For A Minimum Period Of Three Years14. Enough Diluents And Abo Grouping Cards For 100 Tests And Coomb’S Card For 400 Tests With Adequate Diluents., 15. Warranty: 2 Years , Colorimeter- For Hemoglobin Estimation By Drabkins Method Specification:1. It Should Be Portable & Work On 220V & 5 Amp.2.It Should Have Built In Minimum Of 3 Filters With 500, 540 And 600Nm 3. It Should Come With Minimum Of 5 Cuvettes4. Display Should Be Digital5. It Should Be Easily Calibrated 6. Warranty-2 Years , Digital Ph Meter With 3 Standard Buffersspecification: 1. Should Have Working Range From 0 To 14., 2. Should Have Resolution 0.1/0.01 Ph 3. Should Have Temperature Compensation Zero To 100 Degree C With Atc4. Should Have Rs.232C Output And Supply Data Connector Cable5. Should Have Automatic Calibration Facility., 6. Should Have 3 Stage Calibration.7. Should Have Digital Display With 0.001 Ph Unit Readability, 8. Should Supply Tri-Combination Ph/Atc Electrode 9. Should Supply Electrode + Standard Buffer Solution (Ph 4.0, 7.0, 10.01 X 50Ml For Each Bottle) + Standard Electrode Holder +Ac /Dc Adaptor. 10. Should Be Provided With An Electrode Holder/Arm With Smooth Movement, 11. Warranty - 1 Year , Blood Bag Multifunction Hand Striper, Sealer And Cutterspecification: 1. The Body Should Be Made Of Pure Stainless Steel 2.The Handles Should Be Covered With Plastisol 3. Weight Should Be Less Than 200 Gms. 4. Should Be Certified By Ce And Iso 9001 5. Easy To Handle, Strip, Mix, Seal And Cut During Non Use 6. Warranty: 2 Years , Induction Stove Description: Required To Boil Milk And Water For Donor Refreshment Specification: 1. Single Stove, 2. Heating With Warming Facility3. Child Lock, 4. Capable Of Cooking Under Fan/In Ac 5. Protection From Over Heating, 6. Surface Safe To Touch During Operation 7. Protection From Spilling Of Food Items, 8. Programmable For Time And Temperature 9. One Touch Fixed Program And Fixed Timer Facility, 10. Digital Display11. Auto Menu, 12. Utensil Detection, 13. Power Saving 14. Bis/Ce/Iso Certified, 15. Warranty - 2 Years , Sonicator - Ultrasoundcleaning Bath Specification: 1. Fitted With Microprocessor Based Digital Temperature Indicator-Cum-Controller At Any Temperature From Ambient +5ºc To 60ºc.2. Should Have A Digital Timer With Settable Range From 0-15 Min Or 0-30 Min (Depending Upon The Capacity Ordered). 3. Extensively Protected Electronic Circuits Means Longer And Safer Operations., 4. High Frequency Electrical Energy Is Converted Into Ultrasound Waves By Means Of Ultrsonic Transducers. 5. Compact, Rugged And Highly Durable System., 6. Efficiency Of 90% Permits Maximum Cleaning Action, Low Power Consumption.7. Extensively Protected Electronic Circuits Means Longer And Safer Operations., 8. Automatic Frequency Tuning For Maximum Output. 9. Input Range Of 170Vac-270Vac, Highest Immunity To Input Supply Variations.10. Pre-Set Auto Degassing Function., 11. Pulse Sweep Power For Better Effective Cleaning.12. To Work On 220/230 V Ac Supply., 13. Warranty: 2 Years , Spectrophotometerspecification: 1. Wave Length Range: 190 To 1100 Nm 2.Spectral Band Width: 1 Nm3. Wave Length Display: 0.1 Nm Increments 4. Wave Length Accuracy: ± 0.1 Nm 5. Photometric System: Double Beam6. Photometric Accuracy: ± 0.002 Abs 7. Baseline Statbility: Less Than 0.0003 Abs8. Noise Level: Within 0.00005 Abs Rms Value (At 700Nm) 9. Warranty: 2 Years , Plasma Expressormanual Specification: 1. Should Be Suitable To Manually Express Blood Components (Plasma, Platelets) From Collection Blood Bags. 2. Front Panel Should Be Spring Loaded To Apply Uniform Pressure On Container Causing Transfer Of Fluid. 3. Compression Plate Should Be Made Of Durable Transparent Acrylic4. Metal Used For The Apparatus Should Be Non-Corrosive And Can Be Cleaned With Antiseptics 5. Base Portion And Vertical Surface Should Be Made To Have Better Strength And Longlasting Performance 6. Quality Certification: Iso 13485 Certified7. User?S List Should Be Attached With Satisfactory Report For The Last Three Years From Three Users With Contact Details. 8. Demonstration Of Performance Of Equipment Is Compulsory In Nearby Area Failing To Which Will Be Disqualification.9. Warranty - 1 Year , Dry Block Incubator Specification: 1. Basic Device Without Exchangeable Thermoblocks. 2. 16 Tube Holders- Test Tube Size 12 X 75Mm And 12 X 100Mm3. Temperature Control Range:-50C To 99 º C. 4. Accuracy Of Temperature Control : At 0º C ± 1.0ºc 5. At 37º C± 0.5ºc And At 90º C± 1.0ºc, 6. Heating-Up Speed: Approx. 5º C / Min 7. Range Of Time Phases 0:01To 99.59 Hrs, 8. Power Supply: 100 - 240 V, 50 - 60 Hz, 9. Precise Temperature Control10. The Temperature And Run Time Can Be Programmed Individually Upto 4 Temperature Levels And 4 Time Phase In Succession, 11. Warranty - 2 Years , Vertical Reagent Refrigeratorspecification: 1. Storage Capacity: Should Be At Least 300 Liters Capacity, 2. Set Temperature 4ºc With Temperature Range 2ºc To 6ºc And Adjustable With Setting Accuracy Of ±0.5ºc3. Refrigeration: Non- Cfc Cooled Refrigeration, 4. Should Have Good Insulation To Maintain Required Temperature5. Should Have Good Metallic Door With Removable Shelves Inside For Easy Cleaning.6. Microprocessor Based Temperature Controller With Integrated Audiovisual Temperature And Power Alarm Function With Digital Monitoring Display.7. Safety Features: Audio Alarm For All The Following Parameters Should Be There: Temperature Fluctuation & Power Failure, Set Point Alarm, Low Alarm Point, Door Opening Audio And Visual Display Alarm. 8. Safety Thermostat To Avoid Negative Temperatures., 9. Should Have Battery Back Up For Temperature Display And Power Alarm., 10. Interval Temperature Hold Over Time In Case Of Power Failure Should Be At Least 1.5 Hours. 11. Should Have Castor Wheels With Locking Facility, 12. Original Literature Of Equipment Should Be Submitted., 13. Manufacturer Should Be Iso 13485 Certified. 14. Firm Should Supply The Relevant Calibration Certificate For The Equipment From Nabl Accredited Lab., 15. User?S List Should Be Provided With Satisfactory Report For The Last Years From Three Licensed Blood Banks With Contact Details.16.Firm Will Have To Supply The Stabilizer If Required Along With The Equipment Free Of Cost., 17. Bidder Have To Arrange Demonstration Of The Quoted Model (If Required)18. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision, 19. Should Provide Datalogger Or Circular Chart Recorder, 20. Warranty: 2 Years , Blood Bag Tube Sealer (Table Top)Specification: 1.Blood Bag Tube Sealer Is A Compact Equipment To Seal The Blood Bag Pilot Tube By Radio Frequency Sealing System, 2. Should Be Capable Of 750 Seals Per Hour Or 1500 Sealing Per Charge Battery. Capable Of Sealing Tubes Of Various Manufacturers Of Blood Bag.3. Should Be For Table Top Use., 4. The Sealing Time Should Be Adjustable Between 0.5-5 Seconds, 5. Sealing Triggering Should Be Automatic 6. Should Detect Wet Tubes, Leakage Or Any Sealing Defect., 7. Should Have Indication Lamps For “Sealing Process” On Handle As Well As Main Unit And Led To Show The Battery Test., 8. No Warm-Up Time Should Be Required.9. Should Ensure Easy Separation Of Tube Segments After The Sealing. Should Have Separable Rupture Line., 10. System Should Run On Both Mains And Battery (More Than 10Hrs. Back Up When Fully Charged).11. Should Be Light Weight Less Than 3 Kg With Carry Bag., 12. Tube Thickness Of Up To 6 Mm Of Diameter And Wall Thickness Up To 0.75 Mm Can Besensed And Sealed Automatically.13. Should Be Able To Making Wide Seal Of 2Mm Thickness., 14. Indication Of Seal In Progress Should Be There., 15. Sealing Time Should Be Less Than 2 Sec., 16. Separable Rupture Line To Separate Tube After Sealing.17. Should Ensure Safety Against Electrical Shock Hazards, Fire Hazards, And Mechanical Hazards. 18. There Should Be No Hemolysis Of Blood In The Tube Segments, 19. No Warm-Up Time Should Be Required, 20. Should Be Able To Withstand Voltage Fluctuation, 21. It Should Be Easy To Clean. 22. Should Be Easy To Handle With The Grip To Hold The Sealers, 23. Splashguard To Protect User From Any Kind Of Blood Splash During Operation., 24. Manufacturer Should Be Iso 13485 Certified. 25. Weight Of Equipment Should Not Exceed 7 Kg., 26. Original Literature Of Equipment Should Be Submitted., 27. Firm Will Have To Supply The Suitable Stabilizer With The Equipment If It Is Essential For The Performance Of The Equipment., 28. Warranty: 2 Years , Electronic Analytical Balancespecification: 1. Electronic Balance With Transparent Case., 2. Digital Display Of Weight And Other Parameters Should Be Available. 3. Readability 1 Mg, 4. Capacity 1 Mg – 2000G, 5. Accuracy ±1 Mg 6. Stabilization Time Less Than 10 Sec, 7. Should Have Facility For Automatic Calibration With Tare Option.8. Original Literature Should Be Attached, 9. User?S List Should Be Attached With Satisfactory Report For The Last Three Years From Three Users With Contact Details.10. Firm Should Supply The Relevant Calibration Certificate For The Equipment From Nabl Accredited Lab., 11. Firm Will Have To Supply The Stabilizer If Required Along With The Equipment Free Of Cost12. Original Literature Of Equipment Should Be Submitted., 13.Firm Should Also Provide The Relevant Temperature Calibration Certificate For The Equipment From Any Nabl Accredited Lab. 14.User?S List Should Be Attached With Satisfactory Report For The Last Three Years From Three Users With Contact Details., 15. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision. 16. Manufacturer Should Be Iso 13485 Certified., 17. Warranty 2 Yrs , Non-Invasive Hemoglobulin Meter Specification: 1. Hemoglobin ° Measurement Range: 7-17 G/Dl ° Precision (1 Sd): 1 G/Dlresolution: 0.1 G/Dl 2. Data Logger With Real Time And Date3. Measured Values Automatically Stored4. Multilingual Data Interface5. Warranty - 2 Yrs , Refrigerated Centrifuge Specification: For Nucleic Acid Or Protein Lysate Preparation And Pcr Reaction 1. Maximum Speed: 20,000 Rpm Or More., 2. Speed Control Accuracy: ± 10 Rpm. 3. Maximum Rcf: 80,000 G (Approx.), 4. Maximum Capacity:20Ml 5. Tube Volume Range: 1.5 Ml – 20Ml, 6. Set Temperature: 0 To 40°C 7. Ambient Temperature 10 To 35°C, 8. Cooling System: Cfc & Hcfc Free 9. Acceleration / Deceleration Profile: 10/10 Or More, 10. Programmability: 20 Or More With Step Run Facility, 11. Power: 210-240 Vac, 50 Hz, 30 A. 12. Machine Should Have Features Like Eye-Balancing Of Samples, Delayed Start/ Stop, Dual Display Of =Run‘ & =Set‘ Parameters, Data Entry Through Key Pad & Touch Pad, Rpm/Rcf Mode, Rotor Life Management Etc.13. Machine Should Accept Rotors Of Other Makes., 14. Should Be Fda Or Ce Or Bis Approved Product, 15. Warranty - 2 Yrs , Donor Couch Specification: 1. Based On Haemodynamic Principles To Allow Blood Volumes To Redistribute With Cushioned Surface For Donor Comfort., 2. Armrest Suitable For Phlebotomy And Better Blood Flow. 3. Automatic Adjustment Of Arm- Rest To Adjust Length More Than 50 Cm And Width Of 15 Cm To Set The Arm Position To The Donor?S Comfort With Adjustment Of Height Mandatory For The Equipment.4. Material Should Be Waterproof With Rounded Borders And Easy To Clean., 5. The Length Of The Couch Should Be 200 Cm To 215 Cm To Accommodate All Type Of Donors.6. Specially Designed For Comfort Of Donor And Phlebotomist, 7. Should Be Able To Accommodate Donor Weight Capacity Of 150Kg Or More., 8. Electronic Remote Adjustment For Height And Comfortable Sitting Position. 9. Provision To Shift The Donor?S Position From “Head High – Foot Low” To “Foot High- Head Low” Or Any Position In Between For Optimal Blood Collection., 10. Only One Button To Reach Shock Position: Head Low In Case Donor Reaction., 11. 2/3 Motors With Separate Control Through Remote For Positioning Of Couch., 12. Electric Motor Should Have Microprocessor Controlled Limit Switch And Safety Circuit. 16. Trolley (Ss 304, Having Atleast Two Shelves With Adjustable Height, Suitable Size) Should Be Provided With Each Couch For Keeping Blood Collection Monitor And Other Consumables., 17. Good Quality Couch Covers (Two Sets) To Be Provided Along With The Couches Including Handles., 18. Original Literature Of Equipment Should Be Submitted. 19. User?S List Should Be Attached With Satisfactory Report For The Last There Years From Three Users With Contact Details., 20. Bidder Have To Arrange Demonstration Of The Quoted Model (If Required) 21. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision., 22. Manufacturer Should Be Iso 13485 Certified., 23. Should Be Supply With Suitable Stabilizer With Bis/Ce Mark. Accessories:- 24. Dust Cover -1, 25. Power Cable-1, 26. Additional Arm Rest (Pair)-01 Pair., 27. Remote Control-1 No, 28. Warranty - 2 Yrs , Automated Tube Stripperspecification: Motorized Metallic Roller & One Free Roller For Smooth Tube Strippingdesigned For Easy Manual Operation With Convenienceeasy To Use Hand Rollerportable Battery Pack, Backup 1000 Cyclesautomatically Strips Tube Once The Metallic Handle Is Pressed Uniform Radial Force Across The Tube-Prevents Abrupt Manual Pressureaudio Vishual Alarm For Over Load Protectionguiding Groove For Correct Tubing Position, Fed Through Rollerssuitable For All Commercially Available Blood Bags3. Warranty - 2 Yrs , Votex Mixer Specification: 1. Adjustable To 100 To 2500Rpm 2. Continuous And Intermittent Touch Control Modes 3. Heavy Cast Metal Base And Suction Cup To Assure Stability Prevent Walking 4. 220-230 Volts Ac, 50 Hz 5. Digital Display:Led6. Capacity Of 2-3 Kg And Orbit Of 35 Mm 7. Ce/Bis Approved8. Warranty - 2 Yrs , Magnetic Strirrer And Barspecification: 1. Digital Temperature Control With Max. Temperature At 380°C.2. Digital Speed Control With Max. Speed Up To 1500Rpm.3. High Resolution Lcd Displays For Actual Temperature And Speed.4. Brushless Dc Motorandmaintenance Free.5. Ceramic Plate For Chemical Resistance And Easy Clean. 6. Aluminium Cover With Ceramic Work Plate7. Hot Warning Sign If Temperature Is Above 50°C.8. Max. Stirring Quantity Of H2o At 5L. 9. External Temperature Control Is Available As Temperature Sensor Pt1000. 10. Warranty - 2 Yrs , Autoclave Specification: 1. Capacity 80-100L, 2. Sterilization Temperature 105-135 Deg C. 3. Pressure Gauge 1 To 1.5 Kg/Sq.Cm., 4. Safety Valve Releasing Pressure200kpa.5. Automatic Adjustable Working Pressure System., 6. Double Walled.7. Inside Boiler Made Of Stainless Steel & Outside Mild Steel Finished In Cream Enamel., 8. Radial Locking System Lid.9. The Panel Is Provided With On/Off Switch, Pressure Gauge, Steam Release Valve & Indicators To Show The Working Of Mains & Pressure Control System.10. Electrically Operated On 220V A/C With Stainless Steel Basket.11. Digital Temperature Controller With Inbuilt Timer That Will Cut Off The Heaters Automatically Afterlapse Of Pre Set Time At The Pre Set Temperature. 12. Microprocessor Based Pid Controller., 13. Height:600Mm. 14. Diameter Inside: 450Mm(24”X18”), 15. Manufacturer Should Be Iso 13485 Certified., 16. Warranty - 2 Yrs , Plasma Hemoglobinometer 1. Modified Azidemethemoglobin Method 2. Warranty - 2 Yrs , Millipore Waterplant1. Warranty - 2 Yrs , Microwave Oven1. Warranty - 2 Yrs , Thermal Temperature Monitor1. Infrared Thermometer2. Rechargeable3. Warranty - 2 Yrs
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 33
5.
Educational and Research Institute #9415623 Technical Bid
Rate Contract For The Procurement Of Consumables/Non-Consumables For The Department Of Clinical Immunology , Note: For All Items, Sample Should Be Submitted. Without Sample Quotation Will Be Rejected Immunoflorescence, Elisa And Other Kits , Ana-Hep-20-10/ Liver Monkey (Igg, Ifa Slide Test (Pack Size 10 X 10 Per Kit) , Anca Ifa Slide Test Kit (Granulocyte, Ethanol/Formaline Fixed)(Per Kit -250 Tests) , Anti-Ds-Dna, Elisa (Per Kit - 96 Tests) , Anti-Cardiolipin-Igg,Elisa (Per Kit - 96 Tests) , Anti-Cardiolipin- Igm, Elisa (Per Kit - 96 Tests) , Anti B2gpi-Igg, Elisa (Per Kit - 96 Tests) , Anti B2gpi-Igm, Elisa (Per Kit - 96 Tests) , Anti Phosphotidyl Serine/Prothrombin Igg, Elisa(Per Kit - 96 Tests) , Anti Phosphotidyl Serine/Prothrombin Igm, Elisa(Per Kit - 96 Tests) , Anti Ccp, Elisa (Per Kit - 96 Tests) , Interferon Gama Release Assay (Per Kit -100 Tests) , Ena - Line Immunoassay (Containing 17 Antigens) (Per Kit-24 Strips) , Myositis Profile 4 - Line Immunoassay (Containing 16 Antigens) (Per Kit-16 Strips) , Autoimmune Liver Disease - Line Immunoassay (Containing 14 Antigens) (Per Kit-16 Strips) , Systemic Selerosis Profile (Nucleoli) Igg - Line Immunoassay (Containing 13 Antigens) (Per Kit -16 Strips) , Anti Mpo/Pr3 And Gbm (Igg) - Line Immunoassay (Containing 3 Antigens) (Per Kit -16 Strips) , Molecular Biology Grade (Mb)Chemicals , Tritonx 100, 100 Ml , Sucrose, 500 Gm , Mgcl2 , 500Gm , Disodium Edta , 500Gm , Sodium Chloride -500Gm , Chloroform- 500Ml , Tris Free Base - 500Gm , Ethanol (Mb Grade) - 500 Ml , Iso Propyl Alcohol (Mb Grade)- 1L , Trizol Ls - 200Ml , Tris Equilibiriated Phenol Ph 7.8 100Ml , Proteinase K - 100Gm , Ammonium Chloride - 500Gm , Ammonium Bicarbonate - 500Gm , 10% Sodium Dodecyl Sulphate (Sds) - 500Gm , Octanol (1 Liter) , Hydrochloric Acid (1 Liter) , Dimethyl Sulphoxide (Dmso) - 100Ml , Taq Dna Polymerase With 10 X Buffer Like Invitrogen - 100U , Dntp’S Set- (4X100µl) 100Mm Each , High Capacity Cdna Synthesis Kit (200 Reaction Per Kit) , Hla B27 Primers B1: 5-Gct Acg Tgg Acg Aca Cgc T -3 (100 ?M) , Hla B27 Primers B2: 5-Ctc Ggt Cag Tct Gtg Cct T -3 (100 ?M) , Hla B27 Primers B3: 5-Tct Cgg Taa Gtc Tgt Gcc Tt -3 (100 ?M) , Hla B27 Primers C1: 5-Tgc Caa Gtg Gag Cac Cca A -3 (100 ?M) , Hla B27 Primers C2: 5-Gca Tct Tgc Tct Gtg Cag At -3 (100 ?M) , Real Time Taqman Universal Mastermix (Compatible For Abi Step One Plus System) - 5Ml , Agarose (Low Eeo) 500Gm , Dna Marker (100 Bp Ladder) (250?G) , Dna Marker (1 Kb Ladder) (250 ?G) , Analytical Grade (Ar)Chemicals , Tris Buffer 500 Gm , Ethanol 500 Ml , Boric Acid 500 Gm , Sodium Chloride -500Gm , Potassium Permanganate 500 Gm , Formaldehyde Solution 500 Ml , Disodium Hydrogen Phosphate 500 Gm , Potassium Dihydrogen Phosphate 500 Gm , Sodium Azide 500 Gm , Potassium Chloride 500 Gm , Tissue Culture (Tc) Grade Chemicals And Consumables , Glycerol 500Ml , Lymphocyte Separation Medium(Ficoll) (Density 1.077 G/Ml - 100Ml , Trypan Blue Solution (0.4%) 100Ml , Dmso - 100Ml , Formaldehyde Solution 500Ml , Para Formaldehyde 16% 500Gm , Pottasium Permanganate Powder 500 Gm , Pbs Sachets (Without Calcium, Magnesium And Phenol Red) (1X) (Pack Size :10 Sachets/Pkt) , Fbs, Us Origin,500 Ml , Syringe Filters (0.2 ?M Ca Membrane, 28 Mm) (Sterile, Ready To Use) , Syringe Filters (0.45 ?M Ca Membrane, 28 Mm) (Sterile, Ready To Use) , Color Changing Tape To For Adequacy Of Sterilization (Per Pack 4 Rolls) , Disposable Graduated Serological Pipettes Sterile (1Ml) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (2Ml) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (5M) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (10Ml) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (25Ml) (Per Pack 100 Nos) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Citrate -8Ml (60/Case) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Heparin -8Ml (60/Case) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Citrate -4Ml (60/Case) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Heparin -4Ml (60/Case) , Hla Typing Kits - Pcr Ssp (The Item No. 5.078 -7.111Are Part Of A Single Test And Therefore Required From A Single Manufacturer) , Hla Class I (A) Typing Kit (Pcr Ssp) (Per Kit-12 Tests) , Hla Class I (B) Typing Kit (Pcr Ssp) (Per Kit-8 Tests) , Hla Class I (C) Typing Kit (Pcr Ssp) (Per Kit-16 Tests) , Hla Class Ii (Drb1) Typing Kit (Pcr Ssp) (Per Kit-40 Tests) , Hla Class Ii (Dqb1) Typing Kit (Pcr Ssp) (Per Kit-24 Tests) , Hla Class I & Ii (A,B, Drb1) Combitray (Per Kit-10 Tests) , Hla Class Ii(Drb1 & Dqb1) Typing Kit (Per Kit-40 Tests) , Hla B51 Typing Kit (Real Time Pcr) (Per Kit-10 Tests) , Hla Typing Kits - Pcr-Sso (Luminex Based) , Hla - A Sso Typing Kit (Per Kit - 50 Test) , Hla - B Sso Typing Kit(Per Kit - 50 Test) , Hla - C Sso Typing Kit (Per Kit - 50 Test) , Hla - Drb1 Sso Typing Kit(Per Kit - 50 Test) , Hla - Dqb1 Sso Typing Kit (Per Kit - 50 Test) , Hla-A-B-Drb1 Pcr Sso Typing Kit (Per Kit - 50 Test) , 96 Well Filter Microplate (50/Pk) , 96 Well Unskirted Costar Plates (50/Pk) , Sealer For 96 Well Costar Plates (100/Pk) , Sape Solution , Sheath Fluid20 Liters Compatible With Luminex 200 , Calibration Kit (25 Doses) Compatible With Luminex 200 , Performance Verification Kit(25 Doses) Compatible With Luminex 200 , 12 Month Pm Kit Compatible With Luminex 200 , Taq Dna Polymerase Compatible For Pcr-Sso Hla Kits (125 Units; 25?L) , Hla Antibody Screening (Luminex Based) , Panel Reactive Antibodieshla Class I (Per Kit - 24 Test) , Panel Reactive Antibodieshla Class Ii (Per Kit - 24 Test) , Panel Reactive Antibodieshla Class I & Class Ii (Per Kit - 96 Test) , Single Antigen Hla Class I (Per Kit - 24 Test) , Single Antigen Hla Class Ii(Per Kit - 24 Test) , Mixed Class I & Class Ii , Donor Specific Antibody Screening By Luminex (Classi & Classii) (Per Kit - 96 Test) , Negative Control Serum , Pe-Conjugated Goat Anti-Human Igg , Pe-Conjugated Streptavidin , Fitc-Conjugated Mouse Anti Human-Igg , Hla Antibody Screening (Flow Cytometer Based) , Class I Positive Control , Class Ii Positive Control , Negative Control , Hla Class I & Ii Screening Test , Hla Class I Screening Test , Hla Class Ii Screening Test , Wash Buffer (10X) , Reagent Pack , Control Beads , Dsa-Xm , Secondary Antibody For Flow Crossmatch , Percp Conjugated Anti Human-Cd3 , Pe Conjugated Anti Human-Cd19 , Fitc Conjugated Mouse Anti Human-Igg , Pe Conjugated Anti Human-Cd22 , Lymphocyte Isolation/Enrichment Kit , Lymphocyte Isolation/Enrichment Tube , Pbmc Isolation Kit , Pbmc Isolation Tube , Anti Hla Positive Control , Anti Hla Positive Control B Cell , Anti Hla Positive Control T Cell , Anti Hla Negative Control , General Consumbles , Screw Cap Centrifuge Tube 50Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Autoclavable Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Plug Seal Cap Centrifuge Tube 50Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Autoclavable. Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Screw Cap Centrifuge Tube 15Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Autoclavable. Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Plug Seal Cap Centrifuge Tube 15Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free.Autoclavable. Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Microcentrifuge Tube, 2 Ml With Hinged Safe-Lock Lid. Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Should Be Suitable For 30,000G And Withstand Upto -86 °C To 100 °C. Should Be Superior Quality And Manufactured Without Slip Agents And Pp Material Confirming To Us Fda 21 Cfr Autoclavable (Per Box 500 Nos) , Microcentrifuge Tube, 1.5 Ml With Hinged Safe-Lock Lid. Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Should Be Suitable For 30,000G And Withstand Upto -86 °C To 100 °C. Should Be Superior Quality And Manufactured Without Slip Agents And Pp Material Confirming To Us Fda 21 Cfr Autoclavable (Per Box 500 Nos) , Microcentrifuge Tube, 0.5 Ml With Hinged Safe-Lock Lid. Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Should Be Suitable For 30,000G And Withstand Upto -86 °C To 100 °C. Should Be Superior Quality And Manufactured Without Slip Agents And Pp Material Confirming To Us Fda 21 Cfr Autoclavable (Per Box 1000 Nos) , Pcr Strips With Flat Cap 0.2Ml (8 Tube Per Strips). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible To Veriti And Verity Propcr System(Per Pack 125 Nos) , Pcr Strips With Flat Cap 0.1Ml (8 Tube Per Strips). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible To Veriti And Verity Propcr System(Per Pack 125 Nos) , Pcr Strips Tubes With Attached Caps 0.2Ml (8 Tubes Per Strip). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible With Veriti And Verity Propcr System (Per Pack 125 Nos) , Pcr Strips Tubes With Attached Caps 0.1Ml (8 Tubes Per Strip). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible With Veriti And Verity Propcr System (Per Pack 125 Nos) , Colorless, Sterile, Dnase, Rnase, Dna, Atp, Pcr Inhibitor, And Pyrogen Free, Virgin Polypropylene, Autoclavable, Low Retention Micropipette Tips: 0.2 – 10?L.(Per Pack 1000 Nos) , Colorless, Sterile, Dnase, Rnase, Dna, Atp, Pcr Inhibitor, And Pyrogen Free, Virgin Polypropylene, Autoclavable,Low Retention Micropipette Tips: 20-200?L.(Per Pack 1000 Nos) , Colorless, Sterile, Dnase, Rnase, Dna, Atp, Pcr Inhibitor, And Pyrogen Free, Virgin Polypropylene, Autoclavable,Low Retention Micropipette Tips: 100-1000?L.(Per Pack 1000 Nos) , Polypropylene Autoclavable Pipette Tip Box0.2–10 ?L. Should Be Sturdy To Resist Tipping While In Use. Hinged Lids To Protects The Tips From Contamination. The Latch Shouldkeep The Box Closed While Not In Use (Per Pack 10 Boxes) , Polypropylene Autoclavable Pipette Tip Box 2–200 ?L. Should Be Sturdy To Resist Tipping While In Use. Hinged Lids To Protects The Tips From Contamination. The Latch Shouldkeep The Box Closed While Not In Use (Per Pack 10 Boxes) , Polypropylene Autoclavable Pipette Tip Box 100-1000?L. Should Be Sturdy To Resist Tipping While In Use. Hinged Lids To Protects The Tips From Contamination. The Latch Shouldkeep The Box Closed While Not In Use (Per Pack 10 Boxes) , Polycarbonate, Cryo Safe Storage Box For 0.5Ml Microcentrifuge Tubes (81 Places). Boxes Should Have Removable, Numbered Transparent Lid, With Frosted Labeling Area. Foam To Hold Tubes Securely. (Per Pack 4 Boxes) , Polycarbonate, Cryo Safe Storage Box For 2Ml/1.5Ml Centrifuge Tubes (81 Places). Boxes Should Have Removable, Numbered Transparent Lid, With Frosted Labeling Area. (Per Pack 4 Boxes) , Polycarbonate, Cryo Safe Storage Box For 15Ml Centrifuge Tubes (81 Places). Boxes Should Have Removable, Numbered Transparent Lid, With Frosted Labeling Area. (Per Pack 4 Boxes) , Autoclavable Polypropylene Microtube Rack For 96 × 0.5 Ml Microcentrifuge Tubes On One Side, Or 96 × 1.5 - 2.0Ml Microcentrifuge Tubes On The Other. The Rack Should Be Arranged In The Standard 8 × 12 Array And Numbered , Heavy Weight Polypropylene, Four-Way Microtube Rack That Can Hold 4 X 50 Ml Tubes; 12 X 15 Ml Tubes; 32 X 1.5-2 Ml Tubes; 32 X 0.5 Ml Tubes , Autoclavablepolypropylene Ria Vials 12X75 Mm (Per Pack 500 Nos) , Autoclavable Self-Standing Dnase, Rnase And Pyrogen Free Cryogenic Vials With Caps (For Liquid Nitrogen Storage) - 1.8Ml (Per Pack 1000 Nos) , Nitrile Gloves; Large: Disposable, Sterile; Latex And Powder-Free With Textured Fingertips To Provide Extra Grip For Wet Or Dry Applications. Should Fulfill Aql 1,5, En 420, En 374 1/5 And En 455 1/2/3 Standards (Per Pack 100 Nos) , Nitrile Gloves; Medium: Disposable, Sterile; Latex And Powder-Free With Textured Fingertips To Provide Extra Grip For Wet Or Dry Applications. Should Fulfill Aql 1,5, En 420, En 374 1/5 And En 455 1/2/3 Standards (Per Pack 100 Nos) , Nitrile Gloves; Small: Disposable, Sterile; Latex And Powder-Free With Textured Fingertips To Provide Extra Grip For Wet Or Dry Applications. Should Fulfill Aql 1,5, En 420, En 374 1/5 And En 455 1/2/3 Standards (Per Pack 100 Nos) , Autoclavable Disposable Bags For Sterilization (Per Pack 100 Nos) , Ph Tablets (Ph 2-8) , Aluminium Foil: Laboratory-Grade Ultra-Clean Foil.Should Be Strong And Puncture-Resistant , 3 Ply Laboratory Tissue Paper Roll (Dimension 9X11) , Laboratory Blotting Papers (Dimension 46 X 57 Cm 238 Grade ). Should Be Thick And Have Quick Aspiration. Should Have Uniform Structure And Strength (Weight And Thickness).Should Be Of Ultrapure Composition And Have A Smooth Surface. , Cryotags For 0.5Ml Tubes (100/Pack) , Cryotags For 1.5Ml Tubes (100/Pack) , Cryotags For 2Mltubes (100/Pack) , Kim Wipes -4.5 X 8 Inch (280/Pack) , Kim Wipes -15 X 17 Inch (280/Pack) , Ethidium Bromide (0.5Ug/Ml) ( 10Ml) , Countess Ii Automated Cell Counter Compatiblecell Counting Chamber Slides (Each Slide With Two Counting Chamber- 10?L Samle And 10?L Trypanblue)(Per Pack - 50 Slide) , Skin Punch Biopsy Needle (2Mm/3Mm) , Disposable Biopsy Gun A Disposable Core Needle Fully Automatic Biopsy Device With High Speed Action Ensuring Quality Core Samples With Minimal Displacement Of Tissue. Should Have 1. 2.2 Cm Penetration Depth With 18G Needle Thickness And 16 Cm Needle Length 2. One Hand Cocking Mechanism And Non-Roll Handle Design Leading To Convenience And Enhanced Control 3. Sleek And Functional Ergonomic Design For Easier Manipulation And Improved Control 4. Dual Trigger Mechanism Allowing Flexibility For The Physician To Use Different Biopsy Techniques As Per Convenience 5. Angled Sample Notch For Enhanced Needle Action 6.Color Coding For Easy And Accurate Gauge Identification , Disposable Biopsy Gun A Disposable Core Needle Fully Automatic Biopsy Device With High Speed Action Ensuring Quality Core Samples With Minimal Displacement Of Tissue. Should Have 1. 2.2 Cm Penetration Depth With 18G Needle Thickness And 20 Cm Needle Length 2. One Hand Cocking Mechanism And Non-Roll Handle Design Leading To Convenience And Enhanced Control 3. Sleek And Functional Ergonomic Design For Easier Manipulation And Improved Control 4. Dual Trigger Mechanism Allowing Flexibility For The Physician To Use Different Biopsy Techniques As Per Convenience 5. Angled Sample Notch For Enhanced Needle Action 6.Color Coding For Easy And Accurate Gauge Identification , Glasswares , Screw Capped Autoclavble Glass Bottles, 1000Ml (Schott Duran/Borosil) , Screw Capped Autoclavable Glass Bottles, 500Ml (Schott Duran/Borosil) , Screw Capped Autoclavble Glass Bottles, 250Ml (Schott Duran/Borosil) , Screw Capped Autoclavble Glass Bottles, 100 Ml (Schott Duran/Borosil) , Equipment (Less Than Rs.100,000/-) Autoclavable Adjustable Volume Single Channel Research Pipettes With Carousel Specification For Pipettes In Sl No. 01 To 06 • Fully Autoclavable Precision Micropipette • Four-Digit Volume Display With Magnifying Space • Quick Lock To Enable Easy Cleaning And Maintenance • Secondary Adjustment To Support For Accurate Pipetting • Precision & Accuracy > 98% • Spring-Loaded Tip Cone • One-Button Operation With Reduced Operating Effort And Active Aerosol Reduction • Lower Operating Forces For Aspiration/Dispensing/Tip Ejection To Limit Strain On The User. • Should Be A Mechanical Air-Cushion Pipette With A Standard 3-Button Operation (One Operating Element Forvolume Selection, One For Pipetting, And One For Tip Ejection) • Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions • Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance Each Item Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Ring (To Prevent Spring Action) Pipette Performance Certificate Should Be Provided Along With The Pipette Or Should Be Easily Downloadable Certification - Us Fda/Ce/Iso Warranty - 1 Year , 01. Adjustable Volume Single Channel Research Pipette: 100-1000?L Random Measurement Error Should Be: 100 ?L: ± 0.6%; ± 0.6 ?L 500 ?L: ± 0.2%; ± 1 ?L 1000 ?L: ± 0.2%; ± 2 ?L Systematic Measurement Error Should Be: 100 ?L: ± 3%; ± 3 ?L 500 ?L: ± 1%; ± 5 ?L 1000 ?L: ± 0.6%; ± 6 ?L , 02. Adjustable Volume Single Channel Research Pipette: 20-200?L Random Measurement Error Should Be: 20 ?L: ± 0.7%; ± 0.14 ?L 100 ?L: ± 0.3%; ± 0.3 ?L 200 ?L: ± 0.2%; ± 0.4 ?L Systematic Measurement Error Should Be: 20 ?L: ± 2.5%; ± 0.5 ?L 100 ?L: ± 1%; ± 1 ?L 200 ?L: ± 0.6%; ± 1.2 ?L , 03. Adjustable Volume Single Channel Research Pipette: 10-100?L Random Measurement Error Should Be: 10 ?L: ± 1%; ± 0.1 ?L 50 ?L: ± 0.3%; ± 0.15 ?L 100 ?L: ± 0.2%; ± 0.2 ?L Systematic Measurement Error Should Be: 10 ?L: ± 3%; ± 0.3 ?L 50 ?L: ± 1%; ± 0.5 ?L 100 ?L: ± 0.8%; ± 0.8 ?L , 04. Adjustable Volume Single Channel Research Pipette: 2-20?L Random Measurement Error Should Be: 2 ?L: ± 1.5%; ± 0.03 ?L 10 ?L: ± 0.6%; ± 0.06 ?L 20 ?L: ± 0.3%; ± 0.06 ?L Systematic Measurement Error Should Be: 2 ?L: ± 5%; ± 0.1 ?L 10 ?L: ± 1.2%; ± 0.12 ?L 20 ?L: ± 1%; ± 0.2 ?L , 05. Adjustable Volume Single Channel Research Pipette: 0.5-10?L Random Measurement Error Should Be : 0.5 ?L: ± 5%; ± 0.025 ?L 1 ?L: ± 1.8%; ± 0.018 ?L 5 ?L: ± 0.8%; ± 0.04 ?L 10 ?L: ± 0.4%; ± 0.04 ?L Systematic Measurement Error Should Be : 0.5 ?L: ± 8%; ± 0.04 ?L 1 ?L: ± 2.5%; ± 0.025 ?L 5 ?L: ± 1.5%; ± 0.075 ?L 10 ?L: ± 1%; ± 0.1 ?L , 06. Adjustable Volume Single Channel Research Pipette: 0.1-2.5?L Random Measurement Error Should Be : 0.1 ?L: ± 12%; ± 0.012 ?L 0.25 ?L: ± 6%; ± 0.015 ?L 1.25 ?L: ± 1.5%; ± 0.01875 ?L 2.5 ?L: ± 0.7%; ± 0.0175 ?L Systematic Measurement Error Should Be : 0.1 ?L: ± 48%; ± 0.048 ?L 0.25 ?L: ± 12%; ± 0.03 ?L 1.25 ?L: ± 2.5%; ± 0.031 ?L 2.5 ?L: ± 1.4%; ± 0.035 ?L , 07. Pipette Carousel Should Be Compatible And Will Be Procured From The Same Manufacturer Of Pippets Listed In Sl No 01 To 06: Specification For Pipette Carousel • Should Carry/Hold Upto Six Single Or Multi-Channel Pipettes • Should Include Rotatable Stand Design • Should Have A Robust Design That Securely Holds And Protects Pipettes • Should Be Easy To Transport From Bench To Bench , Multichannel Pipettewith Three-Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 8 3. Volume Range: 10-100?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes 6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. A Pipette Performance Certificate Should Be Provided Along With The Pipette Or Should Be Easily Downloadable 9.Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 10 ?L: ± 2%; ± 0.2 ?L 50 ?L: ± 0.8%; ± 0.4 ?L 100 ?L: ± 0.3%; ± 0.3 ?L 13. Systematic Measurement Error Should Be : 10 ?L: ± 3%; ± 0.3 ?L 50 ?L: ± 1%; ± 0.5 ?L 100 ?L: ± 0.8%; ± 0.8 ?L 14. The Box Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Clip (To Prevent Spring Action) (X2), O-Ring Tool Certification - Us Fda/Ce/Iso Warranty - 1 Year , Multichannel Pipette With Three-Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 83. Volume Range: 30-300?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes 6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. Apipette Performance Certificate Should Be Provided Along With The Instrument Or Should Be Easily Downloadable 9. Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 30 ?L: ± 1%; ± 0.3 ?L 150 ?L: ± 0.5%; ± 0.75 ?L 300 ?L: ± 0.3%; ± 0.9 ?L 13. Systematic Measurement Error Should Be : 30 ?L: ± 3%; ± 0.9 ?L 150 ?L: ± 1%; ± 1.5 ?L 300 ?L: ± 0.6%; ± 1.8 ?L Certification - Us Fda/Ce/Iso Warranty - 1 Year , Multichannel Pipettewith Three Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 12 3. Volume Range: 10-100?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes 6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. A Pipette Performance Certificate Should Be Provided Along With The Instrument Or Should Be Easily Downloadable 9. Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 10 ?L: ± 2%; ± 0.2 ?L 50 ?L: ± 0.8%; ± 0.4 ?L 100 ?L: ± 0.3%; ± 0.3 ?L 13. Systematic Measurement Error Should Be : 10 ?L: ± 3%; ± 0.3 ?L 50 ?L: ± 1%; ± 0.5 ?L 100 ?L: ± 0.8%; ± 0.8 ?L 14. The Box Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Clip (To Prevent Spring Action) (X2), O-Ring Tool Certification - Us Fda/Ce/Iso Warranty - 1 Year , Multichannel Pipettewith Three-Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 123. Volume Range: 30-300?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. A Pipette Performance Certificate Should Be Provided Along With The Instrument Or Should Be Easily Downloadable 9. Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 30 ?L: ± 1%; ± 0.3 ?L 150 ?L: ± 0.5%; ± 0.75 ?L 300 ?L: ± 0.3%; ± 0.9 ?L 13. Systematic Measurement Error Should Be : 30 ?L: ± 3%; ± 0.9 ?L 150 ?L: ± 1%; ± 1.5 ?L 300 ?L: ± 0.6%; ± 1.8 ?L 14. The Box Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Clip (To Prevent Spring Action) (X2), O-Ring Tool Certification - Us Fda/Ce/Iso Warranty - 1 Year , Tabletop Pulse Oximeter 1. High Resolution 6.4 Color Leddisplay 2.Spo2 Range: 1% To 100% 3. Pulse Rate - 20 To 250 Beats Per Minute (Bpm) 4. Saturation -For Adult-70% To 100% ± 2 Digits, For Neonates- 70% To 100% ± 2 Digits 4. Graded And Color Coded Alarms (2 Stages) 5. Display/Indicators - Pulse Search, Audible Alarms Silenced Or Off, Interference Indicator, Battery Charging, And Satseconds Alarm Management Clock, Pleth Waveform 6.Critical Alarm For Audible And Visual Alarms For High/Low Saturation And Pulse Rate, Low Battery, Sensor Off, And Sensor Disconnect. 7.24 Hrs Graphical Trend With Zoom Facility (Non-Volitive) Adn Should Be Online Sp)@ & Pr Graphical Trends. 8. Suitable For Adult And Paediatric Applications 9. Rechargeable Battery Backup With A Minimum Of Two Hours Using A New, Fully Charged Battery With No Alarms; Optional 10-Hour Battery. 10. Should Be Shockproof And Noise Level In Db - 40 11. Conformity To Manufactures Certification - Iso 9001 & Iso 13485 12 10. Includes: (Per Set) 1. Main Unit With Power Cable, Battery, Adapter Plate,Wall Mount Arm And Channel, Roll Stand,And Carrying Case, 2. Spo2 Extension Cable 3. Reusable Spo2 Dura Sensor (Nellcore) - Adult - 2 Nos, 4. Reusable Spo2 Dura Sensor (Nellcore) - Paediatric - 1 No 5. Warranty - 3 Years 6.Certification - Us Fda/Ce/Iso , Precision Balance Specification : •Maximum Capacity-220 G •Readability | Scale Interval (D) - 0.1 Mg •Repeatability@5% Load - 0.08 Mg •Repeatability @ Maximum Load - 0.1 •Linearity ± -0.2 Mg •Sensitivity Drift Between + 10°C And + 30°C - 1.5 Ppm/K •Settling Time -2 S •Minimum Weight (Usp, 0.1%, Typical) - 0.16 G •Caliberation - Internal Isocal •Typical Measurement Time - = 2.0S •Typical Stabilization Time - = 1.5S •Adjustment -Internal / Profact Advanced •Interfaces -Ethernet (Lan),Rs232 (Integrated/Optional),Usb •Display - 7 Colour Tft Touchscreen •Weighing Pan Dimensions (Wxd) -90 Mm X 90 Mm •Dimensions (Hxwxd)-368 Mm X 214 Mm X 411 Mm •Terminal Size-7 Inch •Should Have Glass Level Indicator With Air Bubble For Centering •Protection : Chemical Resistant Finish Of The Top Housing; Glass Parts Of The Draft Shield Should Be Coated To Reduce Electrostatic Influences; Should Provide In-Use Cover And Dust Cover For Balances With Draft Shield •Certification - Ce /Iso •Warranty -2 Years , Digital Vortex Mixer • Efficient Mixing With Minimal Vibration • Microprocessor Controls • Speed Range: 120 To 3500Rpm • Vibration Orbit: 3.5 To 5Mm • Operating Modes: Touch (Or) Continuous • Controls: 3-Way Power Switch; Speed Knob: Variable 1–10 Dial Marks • Cup Head For Single Tubes And Platform Suitable For Beakers, Flasks Andmicroplates. • Can Be Used At 4 To 40 °C (85% Relative Humidity, Non Condensing), In An Incubator Or Cold Room • Overall Dimensions (Lxwxh): 4.8 X 6.8 X 4.8 In • Electrical (50/60Hz): 120 Volts, 1.2 Amps,150 Watts • Weight: Around 5 Kg • Led Display For Time/Speed, Up/Down Keys For Set-Point Control Warranty -2 Years Certification - Ce/Iso , Digital Magnetic Stirrer With Hot Plate • Stirring Speed Should Be From 100 Rpm To 1500 Rpm. • Maximum Stirring Volume – 6 Litre. • Plate Temperature Regulation Range - +30°C To +550°C. • Temperature Uniformity On The Plate - ±3°C. • Working Plate Heating Time To Reach +300°C – 15 Min. • Maximum Continuous Operation Time – 24 Hour. • Dimension Of The Working Plate - 160Cm ×160Cm×10Cm. • Weight – 3Kg And Blinks Until Set Temperature Is Reached •Digital Led Temperature Display Is Adjustable In 5 °C Increments. •Microprocessor Controlled For Consistent And Repeatable Temperature Setting. •A Separate Temperature Sensor To Provide Power Cut Off If Unit Overheats Ie Automatic Over-Temperature Protection • Working Surface Material – Stainless Steel,Pyroceram Glassor Ceramic That Should Be Chemically Resistant To Acid And Alkali And Should Be Should Be Extremely Durable • Control For Both The Hotplate And Stirrer Should Be Provided With Suitable Indicators. • Exact Temperature Setting Via Digital Display (Led), Digital Error Code Display, And Elevated Control Panel For Protection Against Leaking Liquids •Small Footprint And Low Profile • 230V, 50/60Hz • Warranty – 1 Year • Certification - Ce/Iso , Digital Platform/Gel Rocker • Mounting- Bench Top • Controller - Digital •Should Provide 3-Dimensional Motion For All Applications • Type Of Motor – Brushless Dc • Maximum Load Capacity: Upto 5 Kg • Speed Range In Rpm - 1-70Rpm • Timer Range In Minutes – 99 • Easily Adjustable Rocking Angle: 1 Degree- 15 Degree • Should Have Compact Counter Balance Drive Mechanism To Ensure Stability • Platform Size In Length X Width In Mm X Mm - 380 X 380Mm • Display – Lcd, Display Parameters -Speed With Preset Facility •The Tilt Angle And Speed Should Be Adjustable For Gentle And Thorough Mixing In Gel Trays, Boxes, And Other Flat Vessels •Should Have A Compact Counterbalance Drive Mechanism To Ensure Stability •Should Have Autoclavable Flat Mats • Should Have Maintenance-Free Brushless Motors; • Should Be Safe For Use In Cold Rooms And Incubators. • Should Have Auto Restart After Power Resumption Power Supply - 220 Volts, 50Hz, Single Phase Certification – Iso/ Ce Warranty -2 Years , Laboratory Coolers • Benchtop Coolers That Can Hold Standard Tube And Vial Sizes In Various Matrixes And Featuring Labeled Grids For Fast Identification. • Inserts Compatible For0.2 To 2Ml Tubes • Should Be Molded From Durable Polycarbonate With Locking Handle For Long-Term Use And Filled With Non-Toxic Freezable Gel • Holding Temperature -20°C For 60 Mins • Stackable To Save Space • Certification – Iso/ Ce Warranty - 1 Years , Automatic Pipette Controller • A Light, Ergonomic, Motorized Pipet Controller Designed For Use With Glass And Plastic Serological Pipets From 0.5 To 100Ml • Autoclavable Pipette Cone • Single Handed Operation With Variable Motor Speed • Separate Aspirate And Dispense Speed Controls For Precise Pipetting • Feature A Heavy-Duty Rechargeable Lithium-Ion Battery • Up To 12 Hours Of Continuous Operation Without Recharge • Direct Exhaust Of Liquid Vapour; With Safety Valve & Dual Hydrophilic, Hydrophobic Filter To Prevent Cross-Contamination. • Replaceable Membrane Filter To Protect Device From Contaminants Being Drawn Into Pipet • Lcd Display For Continuous Visualization Of Speed, Modes, And Battery Status • Can Be Used While It Is Charging • Certification – Iso/ Ce Warranty - 2 Years , Digitalph Meter • Perform Easy Measurements And Customizable Four-Meter Channels With Interchangeable Modules • Perform Up To A 6 Point Ph Calibration, Log Up To 2000 Data Point Sets With Time/Date Stamp And Easily Transfer Calibration And Data Logs Via Usb Or Rs232 To A Printer Or Computer • Lcd Display • Temperature Range:-5°C To +105°C; Temperature Accuracy: ±0.1°C; Temperature Resolution 0.1°C • Ph Range: -2 To 20; Ph Accuracy: ±0.002; Ph Resolution: 0.1 • Have Set Point Alarm, High/Low Limit Alarm, Calibration Due Alarm • Numeric Keypads With Menu-Specific Function Keys And Dual Purpose Scroll/Shortcut Keys • Should Come With Ph Electrode Probe, Electrode Stand, 100-240V Universal Power Adapter And Computer Cable • Dimensions (W X L X H), Cm: 28 X 24 X 10; Weight 1Kg • Multi Language Operational Instructions • Certification – Iso/ Ce •Warranty 3 Years , Digital Laboratory Timer • Timing Capacity: 99 Hours, 59 Minutes, 59 Seconds • Count Direction: Up And Down • Clock: Yes • Number Of Channels: 3 • Resolution: 1 Sec • Accuracy: ±0.001% • Alarm: 1 Minute Continous Beep And Visual • Display: Three-Line Lcd, 3/8 H • Certifications: Nist-Traceable • Height (In) - 3, Depth (In) - 1, Width (In) - 3 1/4 • Certification – Iso/ Ce • Warranty - 1 Year , Digital Microplate Shaker With Standard Accessories Should Be Supplied - Compact, Universal Small Shaker Suitable For Shaking All Small Vessels And Microtiter Plates, Wide Range Of Attachments And Attachment Detection, Digital Display Of Speed And Time, Ideal For Use Under Controlled Conditions (4-40° C), Quick And Vibration-Free Operation. • Type Of Movement - Orbital • Orbit Diameter- 2Mm To 3Mm • Speed Range - 300 - 1800 Rpm • Motor Type- Brushless Dc Motor • Precise Speed Control - - ±2% • Maximum Load Up To - 4 Kgs • Timer - Yes • Time Setting Range - Upto 99 Min • Display: Digital Display Of Led (Speed And Time) • Operating Mode - Timer And Continuous Operation • Touch Function - Yes • Number Of Microtiter Plates - 4 • Accessories: 20X 1.5/2.0Ml Microtubes And Replaceable Clampsto Use Different Types Of Standard Microplates • Power - 230V • Certification - Us Fda/Ce/Iso • Warranty- 2 Years , Automatic Washer With Standard Accessories A Complete System With Wash Bottles And Buffers Capable Of Washing Plates With Magnetic And Non-Magnetic Assays For Increased Automation, Higher Throughput, And Better Reproducibility.Magnetic Washer With Ultrasonic Cleaning Incorporated • Microplate Types- 96 Or 384 Well Low Profile, And Standard Height, Solid And Filter Bottom. • Volume Range - 25-3,000 ?L/Well (192-Pin Manifold) 50-3,000 ?L/Well (96-Pin Manifold) •Magnetic Field - Flat Magnetic Design 6800, Ring - 7094 • Number Of Dispensing Channels - 8 •Residual Volume Magnetic Wash- = 2 ?L/Well (96- & 384-Well Plates, Using 96-Tube Manifold For 96 Wells @300 ?L; 192-Tube For 384 Wells@100 ?L) •Dispensing Accuracy- =3%Dispensing Uniformity - Cv =4% Over The Plate •Wash Speed - 96-Wells, 300 ?L/Well, 3 Cycles; <30 Seconds 384-Wells, 100 ?L/Well, 3 Cycles: <80 Seconds •Flow Rates - Adjustable Rates, High Flow To Low Flow; Optimized Rates For Cell Assays •Vacuum Filtration - Selectable, Range From -38 Mmhg To -506 Mmhg•Vacuum Filtration Time Range: 5 To 999 Seconds •Dispense Precision - <3% Cv: 300 ?L/Well (96-Well Washing) <4% Cv: 80 ?L/Well (384-Well Washing) •Should Provide Supply Bottle- 4 L Or 10 L •Should Provide Waste Bottles - 4L, 10L And 20L Waste Bottlesdirect Drain Should Be Available •Should Have High Resolution Led Backlit Touch Screen With Graphical Color Display •Certification - Us Fda/Ce/Iso •Warranty - 2 Years , Vacuum Manifold For 96 Well Filter Plates Suitable For Xmap Based Assays • For Vacuum Filtration Of Multiwell Filter Plates • Vacuum Manifold Should Include Manifold Base, Standard Ring With Gaskets, Support Grid, All Tubing, Valves And Pressure Gauge • Should Have On/Off Control • Should Have A Vacuum Pressure Indicator • Should Include A Gauge To Know The Vacuum Level Applied To The Filter Plate • Should Allow Vacuum Level Adjustments Via A Set Point Knob • Base: Hdpe• Standard Well Ring: Nylon • Deep Well Ring: Hdpe • Gaskets: Epdm • Tubing: Fep-Lined Like Tygon® • Support Grid: Stainless Steel • On/Off Valve: Polypropylene W/ Epdm Seal • Vacuum Control Valve: Brass Socket, Steel Case • Vacuum Gauge: Steel • Should Include A Compatible Vacuum Pump And Vacuum Trap• Should Have Configurations For Deep Well Or Standard Receiver Plates • Ansi/Sbs Compliant Footprintfor Easy Robotic Deck Integration • Should Be Solvent-Resistant Certitification - Us Fda/Ce/Iso Waarranty - 2 Years , Bath Sonicator 3L With Digital Timer And Heater For Probe Cleaning • Ultrasonic Cleaner With Multiple Power Settings To Handle Both Normal And Delicate Cleaning • Should Have A Degas Mode For Improved Cleaning Efficiency • Should Have Adjustable Heating Tunable From 20 Deg C To 80 Deg C For Deeper Cleaning • Should Come With Stainless Steel Tank And Basket • Should Have Timed Operation From 1-30 Minutes • Tank Capacity: 3L • Material: Stainless Steel Ss304 • Ultrasonic Frequency Output: 40000 Hz • Power: 240 Volts Alternating Current • Display: Led Display For Time And Temperature • Control: Easy Push Button • Sturdy Rubber Feet To Prevent Movement While In Use • Heater Power - 200 W Digital Heating Certification : Us Fda/Ce/Iso Warranty - 2 Years
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 10
6.
Housing Urban and Rular Development #9206461 Technical Bid
Purchase Of Various Testing Major Apparatus (Lab Equipment) In Quality Control Labs Under Zone Ajmer, Bikaner,Udaipur-I And Udaipur-Ii , Fully Automatic Servo Controlled Compression Testing Machine (Ctm)-3000 Kn Capacity With Additional Load Frame Of 500 Kn Capacity & Flexure Frame Of 100 Kn Capacity:- Supplying, Fixing Andcommissioning Of Fully Automatic Servo Controlled Compression Testing Machine (Ctm) Of 3000 Kn Capacity Which Should Be Capable Of Conducting Compression Test On Concrete & Mortar Specimensand Allied Products As Per Is : 516 & Is :4031 (Part-6). The Machine Should Be Power Operated With Servo Controlled Motor Capable To Apply The Load Continuous By Without Shock And There Shall Be Large Enough Space Provided For Test Specimen To Accommodate In A Readable Position. Machine Shall Have Good Load Control And Capable Of Applying The Load At The Specified Rate, Uniformly With Automatic Control With Percentage Of Error For Load Shall Not Exceed+1.0% Of The Indicated Load. Thesystem Shall Have An Arrangementfor Automatic Placing System, Which Achieved By The Combination Of Advance Hydraulic And Electronic System. The Systems Can Be Loaded In Load, Displacement Or Strain Control Basis. Complete Machine Unit Shall Conform Tois: 14858-2000 And Is: 9399-1979 And As Per Direction Of Engineer In Charge. The Salient Features And Technical Specification Of The Machine Shall Be As Under :- I) Ctm-3000 Kn Machine Loading Frame - Four Column High Stiffness Welded From With Enough Stabiility . - Heavy Dutymechanical Platens With Spherical Seated Block(Vicker Hardness > 550), Bottom Bearing, Blocks, Auxiliary Plates (Vh > 550) Shall Have Flatness Tolerance Within 0.03 Mm And Squareness And Parallelism Tolerance Within 0.06 Mm Wide.- Base Shall Have Fine Finished Servo Controlled Hydraulic Cylinder With Hardened And Finest Abraded Piston. - Frame With Safety Guard Door And Transparent Fragment Guard (Both Front & Rear) (Ii)Hydraulic Pumping System, It Should Be Compactin Design And Suitable Forthe Supply Of Required Flowand Pressure For Themovementoftheactuactor.Itshallhaveoiltankofadequatecapcityvanetypepump Powered By Three Phase Motor. Anti Vibration Mounting Shall Provided As Standard Along With The Hps. Iii) Micro-Processed (Plc & Hmi) Basedtouch Panel Display & Control System User Friendly Interface Control System With Applicationsoftware Shall Provide The Digitalservo Control, Preciseoperation,Rampgenerationforthemachine,Dataacquisition,Storage,Processing,Analyzing And Reporting Etc For The Continuous Operation Of The System. Iv) Technical Specification Of Ctm (3000 Kn) Capacity -3000 Kn, Platen Size –320 Mm Dia, Ram Dia – 260 Mm, Ram Travel– 50 Mm, Vertical Daylight Clearance –350 Mm, Horizontal Daylight Clearance– 370 Mm, Least Count -0.1 Kn, Pace Rate Controlling -1%, Rate Of Loading– 1.3 Mm/Min (When Running Idle), 0.14 To 032 Mpa/Sec (With Specimen), Motor Capacity– 3 Hp (Min), Power Supply –(240V, 50-60Hg, Three Phase.), Capacity Of Oil Tank–20 Litre, Max. Operating Pressure– 210- 600 Bars, Flow Of Pump– 2 & 4 Lpm (Duel Speed) , Auto Stop & Release Of Pressure– When Specimen Failure, Multi Operation–Compression Test Up To 3000Kn, Up To 500 Kn Range And Flexure Test, Accessories – Spacers- 4Nos, Controller Unit – Auto Pid Operation With Closed Loop Update Rate Of 10 Khz To Control Pace Rate Automatically As Programmed. Start, Stop & Hold Test System, Load Control – 01Kn/Sec To 50 Kn/Sec., Displacement Control–0.01 Mm/Sec To 1Mm/Sec. Load Indication & Control – Coloured Touch Screen Display Of Suitable Size, Test Report– Facility To Print Test Report, Export Data To Ms Excel. Autointernalcalibrationwithoutprovingring,Shortcirclingprotectionoverloadsafetycutoff, Piston Over Travel Safety Cut Off- Shall Be Made In Addition To 3 Kva 3 Ph Servo Control Stabilizer, Technical Specification Of Ctm (500 Kn) Load Frame- Capacity– 500 Kn, Platen Size–256 Mm, Ram Travel (Max) –50Mm, Vertical Daylight Clearance– 340Mm, Horizontal Daylight Clearance– 300Mm, Least Count–0.01 Kn, Load Control–0.1 To 10Kn/Sec., Technical Specification Of Flexure (100 Kn) Load Frame. Capacity–100Kn, Horizontal Clearance–200Mm, Vertical Clearance- 200 (With Piston Of Actuator Retractor Insides), Bottom Bed Length– 1000 Mm, Bearing & Loading Blocks –40Mm Dia (Hardness > 480 Vh) Steel Cylinders., Width Of Bearing Loading Block– 160 Mm (Min) Loading Blocks Distance– 200Mm/ 133Mmc/C - As Per Is 9399, Supporting Block Distance– 600Mm/ 400Mm C/C- As Per Is 9399 , Ram Travel –100Mm, Load Rate – 0.03 To 1.0 Kn/Sec, % Of Error –0.2% Of Maximum Load, Auto Stop/Release Facility And Up To Calculation Of Flexure Strength – Should Be Available. Rates Are Inlusive Of All Taxes . , Digital Marshal Stability Apparatus Supply & Installation Of Digital Marshall Stability Apparatus Suitable For The Measurement Of Resistance To Plastic Flow Of Cylindrical Specimen Of Bituminous Paving Mixture Loaded On The Lateral Surface. The Complete Apparatus Shall Have Sailent Features As Under :- Single Speed , Bench Top Load Frame With Precise Speed, Max. Loading Capacity, 50 Kn., Geared Screw Jack And Motor Drive , Limit Switch Protection For Both Upward And Downward Travel., Thermal Overload Type Power Switch For Electrical Protection, Ball Seated Screw Fitting Located On The Cross Head For Load Cell And Transducers. Digital Indicator, Load Cell 50Kn (With Least Count-0.01Kn) & Lvdt 25Mm (With Least Count - 0.01Mm) With Auto Internal Calibration Facility. Peak Hold Facility To Read Load & Flow Value Untill Reset. Load Cell & Lvdt Shall Be Capable To Calibrated Using Standard Reference.General Specification Of Marshall Machine Shall Be As Under:- (I)Vertical Clearance Max. 470 Mm. & Min. 250 Mm, (Ii)Horizontal Clearance 265 Mm, (Iii)Platen Diameter Min.- 133 Mm, (Iv)Platen Travel- 30Mm, (V)Platen Speed- 50.8 Mm/Min., (Vi)Rated Power- 375Wt., (Vii)Operation Suitablity- 230 Volt, Ac Supply, Following Accessories Shall Be Part Of Supply :- Cylindrical Steel Marshall Mould 101.6 Mm Id - 15 Nos. , Base Plate & Coller- 03 Nos. Marshall Compaction Hammer , 4.50 Kg. Wt. And 45.7 Cm Drop - 02 Nos. Specimen Extractor Plate- 101.6 Mm- 01 Nos Compaction Pedetal With Speciman Holder- 01 Nos. Breaking Head Assembly Complete With Gauge Disc And Flow Meter Pedestal - 01 Nos. The Complete Apparatus Inclusive Accessories Shall Confirm To Astmd 1559, D-6926-04, D-6927-06, Bs : 598-197, En-12697-34And Is : 17127-2019 As Per Direction Of Engineer Incharge Automatic Compactor For Marshal Test Supply Of Automatic Compactor For Bituminous Mixes For 101.6Mm (4) Specimen Having Essential Features Of Fully Automatic Compaction Of Bt Mixes In Uniform Manner. Its Drive Mechanism Should Have To Lift Weight Of 4.50Kg. And Drop It Through A Height Of 457Mm. The Rammer Foot Should Be Removable And Facilitaties Preheating. Compaction Pedestal With Specimen Holder Should Be Fixed To The Base. An Automatic Blow Counter Shall Be Attached That Enables To Preset No. Of Blows Before Each Test And Automatically Stops The Machines On Completion. The Compactor Shall Be Suitable For Operation On 230 V, 50 Hz Single Phase Ac Supply. The Complete Set Of Equipment Shall Confirm To En 12697-10-30 For Preparation Of Marshall Mould Of Bt Mixes As Per Astm D 1559, D 6926-04, D 6927-06 And Is: 17127(2019)As Per Direction Of Engineer-In-Charge.Rates Are Inlusive Of All Taxes . , Mini Concrete Mixer-Tilting Drum Type:- Supply Of Mini Concrete Mixer , Tilting Type Having Mixing Capacity Of 60 Litre ( Drum Capacity Approx. 100 Ltr.) Suitable For Laboratory Use. The Mixer Shall Be Mounted On A Sturdy Mild Steel Frame With Manual Tilting Arrangement , Fitted With 1 Hp Single Phase Electric Motor , Gear Or Belt Drive Mechanism And Two Rubber -Typed Wheels For Portability . Drum Shall Confirm As Per Is : 1791-2020 Complete With Operating Handle , Power Cable Of Min. 3.0 Mtr Long With Power Plug And Standard Accesssories And As Per Direction Of Engineer In Charge. Rates Are Inlusive Of All Taxes . , Infra-Red Lamp Torsion Balance Moisture Meter:- Supply Of Infrared Lamp Torsion Balance Moisture Meter Suitable For Rapid Determination Of Moisture Content In Soil Samples Confirming To Is : 2720 (Part Ii) . The Apparatus Shall Consist Of A Sensitive Torsion Balance With A Capacity Upto 25 Gm And Readability Of 0.001 Gm ,Infrared Heating Lamp Of 250 Watt,Sample Pan And Reflector With Built-In Thermometer Graduated From 40° To 150° Cfor Uniform Heating. The Unit Shall Be Housed In A Suitable Metallic Enclosure With Heat Resistant Finish. It Shall Be Capable Of Determining Moisture Content From 1 To 100%In 0.2 Percent Divisions , Having Steel Spatula Blade 10 Cm Long And 2 Cm Wide . Suitable For 220-230 V , 50 Hz Single Phase And As Per Direction Of Engineer In Charge. Rates Are Inlusive Of All Taxes . , Asphalt Mix Theoritical Density Determination Equipment With Vaccum Pump Supplying Vibrating Table With Vaccum Pump For Theoritical Maximum Specific Gravity & Density Of Bituminous Paving Mixtures Confirming To Astm-D 2041-03 Requirments.The Equipments Should Be Compatible For Testing As Per Test Procedure Mentioned In Irc-111-2009 & Morth Specifications. The Equipments Shall Contain A Main Body Fitted With Digital Vacuum Indicator, Two Vacuum Container, Vibratory Table Shall Operate On Mannual And Automatic Mode To Release The Entrapped Air From Bituminous Mix Sample. The Equipment Shall Be Suitable For Operation On 220 V, 50Hz Single Phase Ac Supply With Following Technical Specifications:- 1- Vacuum Range: - 0-700 Mm Of Hg. 2- Vibration Loading Capacity :- 10 Kg. 3- No. Of Samples : - Two Rates Are Inlusive Of All Taxes . , Tiles Abrasion Testing Machine:- Supply Of Abrasion Testing Machine For Vitrified /Ceramic Glazed Tiles Confirming To To Is:13630 (Part-11) - 2006 Consisting Of Steel Case With An Inbuilt Electric Drive Connected To A Horizontal Supporting Plate With Positions For Test Specimens Ofdimensions Atleast 100 X 100 Mm . The Distance Between The Centre Of The Supporting Plate & Centre Of Each Position Shall Be 195 Mm. The Supporting Plate Shall Rotates At 300+ 10 Rpm With An Eccentricity Of 22.5 Mm. The Test Specimens Shall Held Down With The Aid Of Metal Holders. The Intenal Dia Of Holder Shall Be 83 Mm . The Thickness Of The Rubber Shall Be 9 Mm And The Height Of The Space Under The Holder Shall Be 25.5 Mm. Eight Nos Of Such Holders Should Be Provided. White Fused Aluminium Oxide Grain Size Confirming To Is:11643 Shall Be Supplied 20Kg Alongwith Machine. The Apparatus Switches Off Automatically After Completion Of A Preset Number Of Revolutions And As Per Direction Of Engineer In Charge. Rates Are Inlusive Of All Taxes . Technical Specification Of Appartaus Shall Be As Under :- Dia Of Rotating Disc:- 580 Mm Electric Motor :- 1/2 Hp Single Phase, 230 Volts, 50 Hz, Ac Supply , Portable Core Drilling Machine With 6 Kva Generator Set :- Supply Of Electric Operated Core Drilling Machine With 6.00 Kva Self Start Petrol Operated Generator Set To Drill Out Core Samples From Bitumen Or Concrete Road, Suitable For Vertical Drilling. Machine Must Be Handy, Robust, Compacted, Light Weighted With Minimum Vibration And Suitable Platform. Machine Shall Have Switch With Current Cut Off, Protection Against Overloading Of The Motor Cut Off , Carbon Brushes, Protection Of The Motor One Speed Oil Bath Gear Box Having Optimal Lubrication. Machine Must Have Intergrated Water Supply With Water Pump. The Dobble Precision Bit Advances With Screwed Spindle Capacity With 100Mm & 150Mm Dia Core Drill Bit Each Of Approved Brand, Drilling Stand Spanner, Carbon Brushes Confirming To Astm C-42 As Per Direction Of Engineer In Charge.Rates Are Inlusive Of All Taxes . Technical Specification Of Core Drilling Machine Shall Be As Under :- Input Supply Voltage - 200-240 V, Motor Input- 3200 Watt, Max. Drilling Diameter - 200Mm, Max. Drilling Depth - 400Mm, Stroke- 500 Mm, Rated Speed - 360-850 Rpm, Water Tape - 12Mm, Guide Slabs - 40 Mm Dia, Screwed Spindle - 20 Mm Dia, Supply Of Portable Generator Set Of Any Reputed Company Complying Is Standard 10001-1981 Reaffirmed 2021 & Is 14650-1999 Shall Be Silent Petrol/Gasoline Operated With Battery Self Start Arrangement. Technical Specification Of Generator Set Shall Be As Under :-, Rated Output:- Minimum 6 Kva, Operating Voltage:-230 V Ac, Single Phase 50 Hz, Engine Type:- Petrol /Gasoline Engine, Air Cooled,Four Stroke Starting System:- Self Start (Electric Start With Battery), Noise Level Db (A):- 86 Max, Efficiency Of Alternator:- 84 Min., Fuel Tank Capacity:- Appox. 25 Litre ( For Continous Run Should Be Greater Than 4 Hours At Full Load), Accessories:- Fuel Level Indicator, Circuit Breaker/Overload Protect For Wheels & Handle For Portability. , Thermostatic Electric Oven (Size - 60X60x90 Cm) :- Supply Of Thermostatic Digital Electric Oven (Double-Walled) With Inner Chamber Made Of Stainless Steel And Outer Chamber Powder-Coated Crc Sheet. Oven Shall Be Thermostatically Controlled With A Digital Pid Controller, Capable Of Maintaining Temperature Up To 250°C With Nichrome Heater And Sensors Placed Around The Chamber To Maintain Static Temperature Throughout With High Accuracy. Oven Shall Be Suitable For Drying Soil/ Aggregate Samples To Determine Moisture Content In Geotechnical Investigations. Oven Must Include Forced Air Circulation And Insulation With Glass Wool. It Shall Confirm Tois 5302:1994.The Complete Item Shall Be Supplied As Per Direction Of Engineer In Charge . Rates Are Inlusive Of All Taxes . Technical Specifications Of Electric Oven Shall Be As Under :- Inner Working Size :- 600 X 600 X 900 Mm (W*D*H), Inner Chamber:- Ss 304-Mirror Polished, Outer Chamber:- Fabricated From Crc Material No. Of Trays:-3 Nos Min. Ss Crimped Wire Mesh Shelves Adjustable Insulation:-65 Mm High Density Glass Wool Heating Element:- 80/20 Nichrome Heating Elements Fitted On All Three Sides Temprature Range:- 50 To 250 °C Temprature Accuracy Within:- + 1 °C Temprature Resolution:- 0-1 °C Temprature Sensor:- Pt-100 Type With Pid Controller Power Consumption:-2.5 Kw With Min 2.0 Mtr.Cord Wire And Power Plug , Softening Point (Ring & Ball Method) Apparatus :- Supplying Ring & Ball Apparatus For Measuring The Softening Point Of Bitumen Of Any Grade. Apparatus Shall Have Feature A Magnetic Slisser With Heating Facility And A Digital Temperature Display With Heating Control Through An Integrat Pid. The Apparatus Shall Be Suitabfle For Operation On A 220 V 50Hz Single Phase Ac Supply. The Apparatus Shall Consist Of Followings :- - Tapered Brass Rings (Set Of 2 ) - 1 Set - Ball Centering Guide( 2 Nos ) - 2 Set - Steel Ball Of 9.5Mm Dia - 2 Nos. - Ring Holder- 1 Nos. - Electric Heater - 1 Nos. The Apparatus Shall Confirm All Requirement Mentioned As Pe Is: 1205, Astmd36, E 28, Ip 198, Ip 58, Stpc Pt 3 , Aashto T 53, Bs: 2000, Fn 1427 And As Per Dirction Of Engineer-In-Charge.Rates Are Inlusive Of All Taxes . , Digital Cbr Test Machine :- Supplying, Fixing And Commissioning Digital Cbr Testing Apparatus (Automatic) Complying To Is 9669: 1980 (Reaffirmed 2002) Which Shall Be Capable To Determine Cbr Value Of Soil, Grannular Sub Base & Base Course Material As Per Is: 2720 ( Part-16) . The Machine Shall Have Lcd Display And Data Aquisition System Alongwith Data Display And Storage System. The Complete Item Shall Be Supplied As Per Direction Of Engineer In Charge .Rates Are Inlusive Of All Taxes . Main Features Of Apparatus With Technical Specification Shall Be As Under :- Load Frame Capacity :- 50 Kg. With 2 Column Frame Operation Mode:- Electric Travel Mode:- High & Low Rate Of Travel With Screw Mould & Rammer Assembly :- Shall Comply As Per Is 10074 (Reaffirmed 2000) & Is 9198 (Reaffirmed 2002) Power Supply :- 220 V , Ac, Single Phase Digital Display :- Load , Displacement & Rate Of Loading Mm Per Minute Tare System :- Nullify Initial Load Displacement Transducer Range :- 0-20 Mm Load Cell Capacity :- 50 Kn , Compression Type Maximum Overload :- 110 % Of Rated Capacity Sensing :- Strain Gauge In Full Bridge Confriguation Flow / Displacement Least Count :- 0.01 Mm Accuracy Within + 1% Load Least Count :- 0.1 Kg Accuracy Within + 1% Cbr Value Least Count :-Auto Calculation Of Cbr Value At 2.50 Mm & 5 Mm Accuracy Within + 1% Sensing Element :- Lvdt , Micro Controlled Multiline Lcd Display Calibration :- Auto Internal Calibration Facility For Load & Flow Apparatus Software Shall Be Capable Of Automatically Record Load & Displacement Data And Generation Of Real Time Load-Penetration Curve And Compitable With Window -10 Or Latest Os , Alongwith Generation Graphing And Calculation Which Also Be Exportable In Ms Excel Or Convertible To Pdf Document. , Buoyancy Balance Unit - Supplying & Assembling Of Buoyancy Balance Unit Of 10 Kg Capacityfor Determination Of Density Of Sample, Weight In Water, Volume Of Sample , Water Absorption And Specific Gravity Of Aggregate Etc .The Apparatus Made Of Suitable Frame With Air Tight Door For Precision & Safety. Apparatus Shall Supplied With Isi Marked Density Basket, Water Tight Cylinder And Electronic Balance Of 10 Kg With Lc - 0.1 Gmwith Calibration Certificate Withmin 3.0 Mtr. Power Cord And Power Plug With Battery Back Up System . The Balance Shall Confirm Is:9281 (Part-3 ) -1981 (Reaffirmed 1985 ) With Attatchment Of Under Hook Weighing Arrangement And Will Be Mounted On Suitable Table To Facilitate The Test. The Water Tight Container Shall Be Mounted On A Mechanical Jack, Having Facility Of Up-Downmovement Of The Container For Weight In Air And Water. The Apparatus Shall Confirm The Requirement Of Is:2386 (Part Iii) ,Bs 1881:114, & En 12390-7 And As Per Direction Of Engineer In Charge. Rates Are Inlusive Of All Taxes . , Bitumen Extractor With Explosion Proof Features ;- Supply & Installation Of Bitumen Extractor Machine With Explosion Proof Features Shock Proof Motor Havingelectronic Speed Control With Continuous Display On Screen, Vibration Free Smooth Operation,Rapid Deceleration Brake Control , Bowl Capacity 1500 Grams,Variable Speed 10-3600 Rpm,Suitable For Operation On 220V, 50 Hz, Single Phase, Ac Supply The Complete Set Of Equipment Shallconfirming To En-12697-1, Astm D2172 And Aashto T-58, T-164 As Per Direction Of Engineer .Rates Are Inlusive Of All Taxes . , Digital Universal Penetrometer For Soil Testing With Cone & Cup And Bitumen Testing :- Supplying Digital Universal Penetrometer For Soil & Bitumen Testing The Apparatus Shall Be Of Complete With Stainless Steel Penetration Test Cone, 35Mm Long With A Smooth Polished Surface And An Angle Of 300. The Total Weight Of Cone & Plunger Shall Be 80 Gm. There Shall Be A Facility For Adjusting Cone Height In Relation To The Specimen. The Unit Shall Be Compact With An In Built Timer To Control The Duration Of Penetration , Preset At The Factory To 5 Seconds The Instrument Shall Have Levelling Arrangement With Suitable Screws. Apparatus Shall Be Suitable To Conduct Liquid Limit Test Of Soil By Cone Penetration Method. Following Shall Be Supplied In Addition To Conduct Bitumen Penetration Test. Bitumen Penetration Kit :- - A Plunger Weighing 47.5 Gm. Alongwith 50 Gm. And 100 Gm. Weight. - Replaceable Parts - Penetration Needle, Transfer Dish Made Of Copper Set And Two Aluminium Sample Container. Penetration Cone :- - For Determining The Consistency Of Lubricating Grease And Petroleum. - Device Shall Be Made Of Brass With A Hardened Steel Tip, The Stem Of Cone Shall Be Interchangeable With All Types Of Penetrometer. - Unified Cone Without Any Shoulder Between The Tip And The Body, Weighing 102.5 ± 0.05 Gm. The Apparatus Shall Confirm Standards Ofis: 11196, Is 2720 (Part-5), Bs 1377, Is: 1203, Astm D-5, En-1426, 13179-2 And Is : 1448(Part-60) And As Per Direction Of Engineer-In-Charge.Rates Are Inlusive Of All Taxes . , Digital Constant Temprature Water Bath With Pid Control Supply & Installation Of Double Walled Water Bath With Digital Temperature Controller Cum Indicator With Stirring Arrangement,Inner Chamber Of Ss Material (Fully Argon Welded),Exterior Body Fabricated From Mild Steel , Glass Wool Insulation Between Inner Chamber And Exterior Body To Prevent The Thermal Heat Loss, ,Temperature Range 5 °C Above Ambient To 100 °C (Accuracy ± 0.5 °C), Capacity To Accomodates At Least 6 Nos. Of 101.4Mm Diameter Marshal Moulds Confirming To Astm D1559 As Per Direction Of Engineer Incharge.Rates Are Inlusive Of All Taxes . , Silt & Clay Content Testing Apparatus :- Supply Of Silt & Clay Content Testing Apparatus (Andreason Pipette Type) Complete Set Confirming Is: 2386 (Part-Ii)-1963 For Gravimetric Determination Of Silt , Clay & Fine Dust In Aggregates Upto 20 Micron(20?). Apparatus Shall Include Water Tight Glass Jar ( 1.0 Kg Capacity ) , Rotation Device ( 80 + 20 Rpm ) Andreason Pipette (App. 25 Ml) , Measuring Cylinder ( 1000 Ml ) , Digital Balance ( 250 Gm With Lc 0.001Gm ) Sodium Oxalate (1.0 Kg) And To Be Supplied Complete With Operator Manual & All Required Accessories & As Per Direction Of Engineer In Charge .Rates Are Inlusive Of All Taxes . , Accelerated Curing Tank :- Accelerated Curing Tank Having Capacity To Accommodate 12 Nos. Of Concrete Cube Moulds, With A Facility For Accelerated Curing By Boiling Water Method Up To Temperature Range : 100+/-20C As Per Is Standard Is : 9013. Also It Will Have Capacity For Curing By Warm Water Method At Temperature 55+/-20C. The Whole Body Of Cube Mould With The Sample Of Concrete/Cement Mortar Inside Is To Be Immersed In The Tank And The Tank Is Strong Enough To Bear Heavy Load On Its Platform. Tankwill Consist Of Rectangular Double Walled Metal Cabinet, Inner Chamber Made Thick Gauge Stainless Steel Ss 304 Grade. Outer Chamber Made Of 20 Swg Galvanized Sheet-Powder Coated. Specially Designed L Shaped High Wattage Heaters Will Be Mounted In The Chamber Is Such A Waythat, It Facilitates Easy Replacement. It Shouldhave Facility To Circulate Water Inside The Chamber By Stirrer To Maintain The Uniform Temperature Of Water. Inside The Chamber There Will Be A Heavy Gauge Stainless Steel Perforated Platform With Ribs To Withstand The Heavy Load Of The Cubes. It Shall Also Have A Lid With Lifting Handle To Cover The Chamber. The Front Panel Will Have Power Supply Indicating Lamp And One Main Switch Suitable For Operation On 440V, 50Hz Three Phase, Ac Supply. It Will Also Have A Digital Auto Tuning Pid Temperature Indicator Cum Controller Fitted On The Front Panel, Detailed Technical Specifications As Under. Overall Dimensions: 1360X800x970 (Lxwxd)Mm Working Dimensions : 790X635x560mm (Lxwxh) Type Of Model : Floor Standing Model Insulation Thickness : 50 Mm Temperature Controller : Microprocessor Base Temperature Range : 50 C. Above Ambient To 1000 C. Temperature Display : Led Digital Display Temperature Sensor : Pt-100 Sensor Temperature Resolution : 0.10 C. Power Wattage : 7.5 Kw Power Supply : 440 V., Ac Three Phase Rates Are Inlusive Of All Taxes .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
7.
Educational and Research Institute #9013399 Technical Bid
Rate Contract For Supply Of Consumables And Nonconsumables For The Department Of Clinical Immunology , Immunoflorescence, Elisa And Other Kits Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Ana-Hep-20-10 / Liver Monkey ( Igg, Ifa Slide Test ( Pack Size 10 X 10 Per Kit ) , Anca Ifa Slide Test Kit ( Granulocyte, Ethanol / Formaline Fixed ) ( Per Kit -250 Tests ) , Anca-Pr3, Elisa ( Per Kit - 96 Tests ) , Anca -Mpo, Elisa ( Per Kit - 96 Tests ) , Anti-Ds-Dna, Elisa ( Per Kit - 96 Tests ) , Anti-Cardiolipin-Igg, Elisa ( Per Kit - 96 Tests ) , Anti-Cardiolipin- Igm, Elisa ( Per Kit - 96 Tests ) , Anti B2gpi-Igg, Elisa ( Per Kit - 96 Tests ) , Anti B2gpi-Igm, Elisa ( Per Kit - 96 Tests ) , Anti Phosphotidyl Serine / Prothrombin Igg, Elisa ( Per Kit - 96 Tests ) , Anti Phosphotidyl Serine / Prothrombin Igm, Elisa ( Per Kit - 96 Tests ) , Anti Ccp, Elisa ( Per Kit - 96 Tests ) , Anti Carb P ( Per Kit - 96 Tests ) , Anti Gbm, Elisa ( Per Kit - 96 Tests ) , Functionality Test Of Complement Ch50 ( Per Kit - 96 Tests ) , Functionality Test Of Complement Ah50 ( Per Kit - 96 Tests ) , Human Anti-Tissue Transglutaminase ( Ttg ) Antibody Iga Elisa Kit ( Per Kit - 96 Tests ) , Ana Immunoblot - Line Immunoassay ( Containing 17 Antigens ) ( Per Kit-24 Strips ) , Myositis Profile 4- Line Immunoassay ( Containing 16 Antigens ) ( Per Kit-16 Strips ) , Autoimmune Liver Disease - Line Immunoassay ( Containing 14 Antigens ) ( Per Kit-16 Strips ) , Systemic Selerosis Profile ( Nucleoli ) Igg ( Containing 13 Antigens ) ( Per Kit -16 Strips ) , Molecular Biology Gradechemicals And Consumables: Calculate For 2500 Extraction Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Tritonx 100 , 50 Ml , Sucrose, 500 Gm , Mgcl2 , 500Gm , Disodium Edta , 500Gm , Sodium Chloride -500Gm , Chloroform- 500Ml , Tris Free Base - 500Gm , Ethanol ( Mb Grade ) - 500 Ml , Iso Propyl Alcohol ( Mb Grade ) - 500Ml , Trizol Ls - 200Ml , Tris Equilibiriated Phenol Ph 7.8 , Proteinase K - 100Gm , Ammonium Chloride - 500Gm , Ammonium Bicarbonate - 500Gm , Sodium Hydroxide - 500Gm , 10% Sodium Dodecyl Sulphate ( Sds ) - 500Gm , Octanol ( 1 Liter ) , Hydrochloric Acid ( 1 Liter ) , Hydroxy Quinoline -500Gm , Dimethyl Sulphoxide ( Dmso ) - 100Ml , Mgcl2 ( 25 Mm ) - 1Ml , Taq Dna Polymerase With 10 X Buffer Like Invitrogen - 1000U , Dntp’S Set- 100Mm , High Capacity Cdna Synthesis Kit ( 200 Reaction Per Kit ) , Protease Inhibitors - 10Ml , Hla B27 Primers B1: 5-Gct Acg Tgg Acg Aca Cgc T -3 ( 100 ?M ) , Hla B27 Primers B2: 5-Ctc Ggt Cag Tct Gtg Cct T -3 ( 100 ?M ) , Hla B27 Primers B3: 5-Tct Cgg Taa Gtc Tgt Gcc Tt -3 ( 100 ?M ) , Hla B27 Primers C1: 5-Tgc Caa Gtg Gag Cac Cca A -3 ( 100 ?M ) , Hla B27 Primers C2: 5-Gca Tct Tgc Tct Gtg Cag At -3 ( 100 ?M ) , Multiplex Pcr Kit With Q Solution ( 100 Reactions ) , Dnase Rnase Free Water ( 100Ml ) , Real Time Taqman Universal Mastermix ( Compatible For Abi Step One Plus System ) - 5Ml , Gel Red 10Ml , Agarose ( Low Eeo ) 500Gm , Dna Marker ( 100 Bp Ladder ) ( 100 ?G / Ml ) , Dna Marker ( 1 Kb Ladder ) ( 100 ?G / Ml ) , Ssrna Marker ( 28S, 18S ) ( 100 ?G / Ml ) , Rna Loading Dye ( 100 Ml ) , Diamino Benzidine10g , Analytical Grade ( Ar ) Chemicals Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Tris Buffer 500 Gm , Ethanol 500 Ml , Hydrochloric Acid 500 Ml , Beta-Mercapto Ethanol 100 Ml , Glacial Acetic Acid 500 Ml , Boric Acid 500 Gm , Sodium Dodecyl Sulphate ( Sds ) 500 Gm , Sodium Hydroxide Pellets 500 Gm , Potassium Permanganate 500 Gm , Formaldehyde Solution 500 Gm , Disodium Hydrogen Phosphate 500 Gm , Potassium Dihydrogen Phosphate 500 Gm , Sodium Azide 500 Gm , Potassium Chloride 500 Gm , Tissue Culture ( Tc ) Grade Chemicalsand Consumables Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Rpmi 1640 With L-Glutamine And Sodium Bi-Carbonate ( Solution ) ( 1 Liter ) , Penicillin – Streptomycin Solution100ml , Antimycotic Solution 100Ml , Fetal Calf Serum ( Fcs ) 500Ml , Hanks Balanced Salt Solution 1 Liter , Dmem With L Glutamine Without Sodium Bicarbonate 1 Liter , Sodium Bicarbonate 500Gm , Glycerol 500Ml , Bovine Serum Albumin 50Gm , Pbs ( Ph 7.4 ) Calcium And Mg Free 1 Liter , Phyto Haemagglutination ( Pha ) 50Mg , Concavalin A ( Con A ) 250Mg , Lipopolysaccharide ( Lps ) 500 ?G , Di-Sodium Edta ( Tc Grade ) 500Gm , Lymphocyteseparation Medium ( Ficoll ) ( Density 1.077 G / Ml - 500Ml , Trypan Blue Solution ( 0.4% ) 50Ml , Dmso - Tc Grade 100Ml , Formaldehyde Solution 1 Liter , Para Formaldehyde 16% , Pottasium Permanganate Powder 500 Gm , Sodium Citrate 500 Gm , X- Vivo 15 Medium 1 Litre , Human Collagenase Type I ( 50 Mg ) , Recombinant Human Gm-Csf ( 10 Ug ) , Recombinant Human Il-1Beta ( 1 Mg ) , Recombinant Human Il-4 ( 1 Mg ) , Recombinant Human Il-10 ( 25 Ug ) , Recombinant Human Il-2 ( 500 Ug ) , Recombinant Human Il-6 ( 50 Ug ) , Recombinant Human Tgf-Beta ( 10 Ug ) , Recombinant Human Tnf-Alpha ( 100 Ug ) , Citrullinated Vimentin ( 10 Ug ) , Trypsin 0.5% Powder ( 100 Mg ) , Anti Human Cd3 / Cd28 Monoclonal Antibody 100 Ug , Dmem Media, High Glucose, L- Glutamine, Phenol Red 500 Ml , Pbs Sachets ( Without Calcium, Magnesium And Phenol Red ) ( 1X ) ( Pack Size :10 / Pkt ) , Calcium Chloride 500 Gm , Magnesium Chloride 500 Gm , Hbss ( Without Calcium Magnesium / Phenol Red ) ( 1X ) 500 Ml , Hbss ( Without Calcium Magnesium / / Phenol Red ) ( 1X ) 500 Ml , Fbs, Us Origin, 500 Ml , Alkaline Hypochlorite Solution , Ammonium Chloride 500 Gm , Sodium Bicarbonate 500 Gm , Pma 1 Mg , Catalase ( C40 ) 100 Mg , Albumin ( Human Fraction V ) 1 Mg , Edta 500 Gm , Trypsin Edta ( 0.25% ) 100 Ml , Sodium Pyruvate ( 100 Mm ) 100 Ml , Dpbs, No Calcium, No Magnesium 1000 Ml , Mccoys 5A Medium With L-Glutamine Without Sodium Bicarbonate - 1 Liter ( Powder Form ) ( 10 / Pack ) , Cell Culture Flask ( Polystyrene, Angled Neck, Filter Cap, Treated- Cell Attachment ) ( 25 Cm2 ) , Cell Culture Flask ( Polystyrene ) ( Angled Neck, Filter Cap ) ( Treated-Cell Attachment ) ( 75 Cm2 ) , Cell Culture Flask ( Polystyrene ) ( Angled Neck, Filter Cap ) ( Treated For Cell Attachment ) ( 175 Cm2 ) , Cell-Culture Multidishes ( 6 Well ) ( Treated For Cell Attachment ) Polystyrene , Cell-Culture Multidishes ( 12 Wel ) ( Treated For Cell Attachment ) Polystyrene , Cell-Culture Multidishes ( 24 Well ) ( Treated For Cell Attachment ) Polystyrene , Cell-Culture Multidishes ( 96 Well ) ( Treated For Cell Attachment ) Polystyrene , Cell Strainers ( 70 ?M ) Sterile , Cell Strainers ( 100 ?M ) Sterile , Cell Strainer Pestle Sterile , Syringe Filters ( 0.2 ?M Ca Membrane, 28 Mm ) ( Sterile, Ready To Use ) , Syringe Filters ( 0.45 ?M Ca Membrane, 28 Mm ) ( Sterile, Ready To Use ) , Multiwell Cell Culture Plates ( 6 Wells ) ( Per Pack 100 Nos ) , Multiwell Cell Culture Plates ( 12 Wells ) ( Per Pack 100 Nos ) , Multiwell Cell Culture Plates ( 24 Wells ) ( Per Pack 100 Nos ) , Multiwell Cell Culture Plates ( 96 Wells ) ( Per Pack 100 Nos ) , Cell Culture Flasks ( 25 Cm2 ) ( Per Pack 100 Nos ) , Cell Culture Flasks ( 75 Cm2 ) ( Per Pack 100 Nos ) , Autoclavable Membrane Filter Holder ( Stainless Steel- 25 Mm Dia ) ( Per Pack 10 Nos ) , Autoclavable Membrane Filter Holder ( Stainless Steel-47 Mm Dia ) ( Per Pack 10 Nos ) , Autoclavable Suiny / Syringe Filteration Unit ( 25Mm Dia ) ( Per Pack 100 Nos ) , Autoclavable Suiny / Syringe Filteration Unit ( 47Mm Dia ) ( Per Pack 100 Nos ) , 0.22 ?M ( 25Mm ) Disposable Membrane Filter For Culture Medium Filtration ( Per Pack 100 Nos ) , 0.45 ?M ( 25Mm ) Disposable Membrane Filter For Culture Medium Filtration ( Per Pack 100 Nos ) , 0.22 ?M ( 47Mm ) Disposable Membrane Filter For Culture Medium Filtration ( Per Pack 100 Nos ) , 0.45 ?M ( 47Mm ) Disposable Membrane Filter For Culture Medium Filtration ( Per Pack 100 Nos ) , Color Changing Tape To For Adequacy Of Sterilization ( Per Pack 4 Rolls ) , Disposable Graduated Serological Pipettes Sterile ( 1Ml, 2Ml, 5Ml, 10Ml, 25Ml ) ( Per Pack 100 Nos ) , Vaccum Pump Tygon Tubing , Sterile Disposable Filter Units With Sfca Membrane ( 0.2 ?M, 30 Mm ) 150 Ml , Sepmate Tube 50Ml100 / Pack , Sepmate Tube 15Ml 100 / Pack , Vacutainer With Clot Activator, Silicone Coated - 5Ml 100 / Pack , Vacutainer With Sodium Heparin - 4Ml 100 / Pack , Mononuclear Cell Preparation Tubes ( Cpt ) With Sodium Citrate -8Ml ( 60 / Case ) , Mononuclear Cell Preparation Tubes ( Cpt ) With Sodium Heparin -8Ml ( 60 / Case ) , Mononuclear Cell Preparation Tubes ( Cpt ) With Sodium Citrate -4Ml ( 60 / Case ) , Mononuclear Cell Preparation Tubes ( Cpt ) With Sodium Heparin -4Ml ( 60 / Case ) , Hla Typing Kits - Pcr Ssp ( The Item No. 166 - 73 Are Part Of A Single Test And Therefore Required From A Single Manufacturer ) Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Hla Class I ( A ) Typing Kit ( Pcr Ssp ) ( Per Kit-24 Tests ) , Hla Class I ( B ) Typing Kit ( Pcr Ssp ) ( Per Kit-24 Tests ) , Hla Class I ( C ) Typing Kit ( Pcr Ssp ) ( Per Kit-24 Tests ) , Hla Class Ii ( Drb1 ) Typing Kit ( Pcr Ssp ) ( Per Kit-24 Tests ) , Hla Class Ii ( Dqb1 ) Typing Kit ( Pcr Ssp ) ( Per Kit-24 Tests ) , Hla Class I & Ii ( A, B, Dr ) Combitray ( Per Kit-10 Tests ) , Hla Drb1 & Dqb1 Combitray ( Per Kit-48 Tests ) , Hla B51 Typing Kit ( Real Time Pcr ) ( Per Kit-10 Tests ) , Hla Typing Kits - Pcr-Sso ( For Luminex ) Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Hla - A Sso Typing Kit , Hla - B Sso Typing Kit , Hla - C Sso Typing Kit , Hla - Drb1 Sso Typing Kit , Hla - Dqb1 Sso Typing Kit , Hla-A-B-Drb1 Pcr Sso Typing Kit , Hla-A-B-Drb1-Dqb1 Pcr Sso Typing Kit , 96 Well Filter Microplate , 96 Well Unskirted Costar Plates , Sealer For 96 Well Costar Plates , Sape Solution , Sheath Fluid20 Liters Compatible With Luminex 200 , Calibration Kit ( 25 Doses ) Compatible With Luminex 200 , Performance Verification Kit ( 25 Doses ) Compatible With Luminex 200 , 12 Month Pm Kit Compatible With Luminex 200 , Hla Antibody Screening ( Luminex Based ) Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Panel Reactive Antibodieshla Class I , Panel Reactive Antibodieshla Class Ii , Panel Reactive Antibodieshla Class I & Class Ii , Single Antigen Hla Class I , Single Antigen Hla Class Ii , Mixed Class I & Class Ii , Negative Controls , Pe Conjugated Goat Anti-Human Igg , Donor Specific Antibody Screening By Luminex ( Classi & Classii ) , Hla Antibody Screening ( Flow Cytometer Based ) Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Class I Positive Control , Class Ii Positive Control , Negative Control , Hla Class I & Ii Screening Test , Hla Class I Screening Test , Hla Class Ii Screening Test , Wash Buffer ( 10X ) , Reagent Pack , Control Beads , Dsa-Xm , Secondary Antibody For Flow Crossmatch , Percp Conjugated Anti Human-Cd3 , Pe Conjugated Anti Human-Cd19 , Fitc Conjugated Mouse Anti Human-Igg , Pe Conjugated Anti Human-Cd22 , Lymphocyte Isolation / Enrichment Kit , Lymphocyte Isolation / Enrichment Tube , Pbmc Isolation Kit , Pbmc Isolation Tube , Anti Hla Positive Control , Anti Hla Positive Control B Cell , Anti Hla Positive Control T Cell , Anti Hla Negative Control , General Consumbles Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Polypropylene Centrifuge Tube 50Ml Sterile. Dnase, Rnase Free ( Per Box 216 Nos ) , Polypropylene Centrifuge Tube 15Ml Sterile. Dnase, Rnase Free ( Per Box 500 Nos ) , Polypropylene Centrifuge Tube 2Ml Sterile. Dnase, Rnase Free ( Per Box 500 Nos ) , Polypropylene Centrifuge Tube 1.5Ml Sterile. Dnase, Rnase Free ( Per Box 500 Nos ) , Polypropylene Centrifuge Tube 0.5Ml Sterile. Dnase, Rnase Free ( Per Box 1000 Nos ) , Polypropylene Centrifuge Tube 0.2Ml Sterile. Dnase, Rnase Free ( Per Box 1000 Nos ) , Dnase Rnase Free Pcr Strips With Cap 0.2 Ml ( 8 Tube Per Strips ) ( Per Pack 100 Nos ) , Dnase Rnase Free Pcr Tubes With Cap 0.1 Ml - Compatible To Abi Veriti Pcr System ( Per Pack- 1000 Nos ) , Dnase Rnase Free Pcr Strips With Cap 0.1 Ml - Compatible To Abi Veriti Pcr System ( 8 Tube Per Strips ) ( Per Pack - 100 Nos ) , Polypropylene Pipette Tips 0.2 – 10 ?L Sterile. Dnase, Rnase Free ( Per Box 1000 Nos ) , Polypropylene Pipette Tips 20-200 ?L Sterile. Dnase, Rnase Free ( Per Box 1000 Nos ) , Polypropylene Pipette Tips 100-1000 ?L Sterile. Dnase, Rnase Free ( Per Box 500 Nos ) , Polypropylene Pipette Tipsbox0.2 – 10 ?L. ( Per Pack 4 Boxes ) , Polypropylene Pipette Tips Box20-200 ?L. ( Per Pack 4 Boxes ) , Polypropylene Pipette Tipsbox 100-1000 ?L ( Per Pack 4 Boxes ) , Polypropylene Pipette Tipsbox 1-10 Ml ( Per Pack 5 Boxes ) , Micro Centrifuge Tube Storage Box For 0.5Ml ( 81 Places ) ( Per Pack 4 Boxes ) , Cryostorage Box For 15Ml Conical Bottom Polypropylene Screw Cap Tubes ( Per Pack 4 Boxes ) , Micro Centrifuge Tube Storage Box For 2Ml / 1.8 Ml ( 81 Places ) ( Per Pack 4 Boxes ) , Micro Centrifuge Tube Rack For 0.5Ml ( Min 24 Places ) ( Per Pack 4 Nos ) , Micro Centrifuge Tube Rack For 2Ml ( Min 24 Places ) ( Per Pack 4 Nos ) , Storage Rack For 15 Ml For Poly Propylene Tubes , Storage Rack For 5 Ml For Poly Propylene Tubes , Storage Rack For 5 Mlfor Glass Tubes , Sterile Powder Free Nitrile Gloves ( Large ) ( Per Pack 100 Nos ) , Sterile Powder Free Nitrile Gloves ( Medium ) ( Per Pack 100 Nos ) , Sterile Powder Free Nitrile Gloves ( Small ) ( Per Pack 100 Nos ) , Autoclavable Disposable Bags For Sterilization. ( Per Pack 100 Nos ) , Autoclavablepolypropylene Ria Vials 12X75 Mm ( Per Pack 1000 Nos ) , Autoclavable Self Standing Dnase, Rnase, Pyrogen Free Cryogenic Vials ( For Liquid Nitrogen Storage ) - 2Ml ( Per Pack 500 Nos ) , Autoclavable Self Standing Dnase, Rnase, Pyrogen Free Cryogenic Vials ( For Liquid Nitrogen Storage ) - 5Ml ( Per Pack 500 Nos ) , Purified Protein Derivative ( Mantoux ) - Ppd, 5Ml Per Vial , Ph Tablets ( Ph 2-8 ) , Magnetic Stirring Bar With Pivot Ring ( 8 X 30 Mm ) . , Aluminium Foil , 3 Ply Laboratory Tissue Paper Roll ( Dimension 9X11 ) , Kim Wipes -4.5 X 8 Inch , Kim Wipes -15 X 17 Inch , Reservoir Cans With Tap ( 5 Litres ) , Pipette Stand For Eppendorf Micropipettes , Sterile Pasteur Pipettes Disposables , Ethidium Bromide ( 0.5Ug / Ml ) ( 50Ml ) , Countess Ii Automated Cell Counter Compatiblecell Counting Chamber Slides ( Each Slide With Two Counting Chamber- 10?L Samle And 10?L Trypanblue ) ( Per Pack - 50 Nos ) , Pe-Conjugated Streptavidin , Hemocytometer , Uristicks For Glucose Testing ( Per Box -100 Nos ) , Uristicks For Ketone Testing ( Per Box -100 Nos ) , Uristicks For Protein Tests ( Per Box -100 Nos ) , Laboratory Blotting Papers , Laboratory Blotting Papers - Aspiration , Skin Punch Biopsy Needle ( 2Mm / 3Mm ) , Cryotags For 2Ml, 1.5Ml & 0.5Ml Tubes , Rna Storage Solution ( With 10% Dmso ) - 100Ml , Glasswares Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejected , Graduated, Autoclavable, Glass Pipettes – 10 Ml , Graduated, Autoclavable, Glass Pipettes – 5 Ml , Graduated, Autoclavable, Glass Pipettes – 2 Ml , Graduated, Autoclavable, Glass Pipettes – 1Ml , Screw Capped Autoclavble Glass Bottles, 500Ml ( Schott Duran / Borosil ) , Screw Capped Autoclavble Glass Bottles, 1000Ml ( Schott Duran / Borosil ) , Screw Capped Autoclavble Glass Bottles, 250Ml ( Schott Duran / Borosil ) , Screw Capped Autoclavble Glass Bottles, 100 Ml ( Schott Duran / Borosil ) , Equipment ( Less Than Rs.100, 000 / - ) • Autoclavable Adjustable Volume Single Channel Research Pipettes 0.1-2.5?L; 0.5-10?L; 2-20?L, 10-100 ?L; 20-200?L, 100-1000?L With Carousel Specification For Pipette • Fully Autoclavable Precision Micropipette • Four Digit Volume Display With Magnifying Space • Quick Lock To Enable Easy Cleaning And Maintenance • Secondary Adjustment To Support For Accurate Pipetting • Spring Loaded Tip Cone • One-Button Operation With Reduced Operating Effort And Active Aerosol Reduction • Precision & Accuracy Above 98% • Lower Operating Forces For Aspiration / Dispensing / Tip Ejection To Limit Strain On The User. Specification For Pipette Carousel • Carries Up To Six Single Or Multi-Channel Pipettes • Includes Rotatable Stand With Design That Holds All Pipettes • Robust Design That Securely Holds And Protects Pipettes • Handle For Easy Transport From Bench To Bench , 1. Adjustable Volume Single Channel Research Pipettes 100-1000?L , 2. Adjustable Volume Single Channel Research Pipettes 20-200?L , 3. Adjustable Volume Single Channel Research Pipettes 0.5-10?L , 4. Adjustable Volume Single Channel Research Pipettes 0.1-2.5?L , 5. Adjustable Volume Single Channel Research Pipettes 2-20?L , 6. Adjustable Volume Single Channel Research Pipettes 10-100?L , 7. Pipette Carousel , Equipment ( Less Than Rs.100, 000 / - ) , Laboratory Centrifuge • Maximun Speed: 15000Rpm • Rotor: Fixed Angle • Maximum Capacity 12 X 1.5Ml Or 12X2mltubes & Compatible Adaptors For 0.5Ml And Pcr Strips • Rotor Should Be Autoclaved At 121°C For 20 Minutes • Minimal Sample Heat Transfer — Maximum Of 12°C After 20 Minutes At Max Speed • Aerosol Tight Rotors • Availability Of Short Spin & Soft Brake Options • Imbalance And Tilt Safety Cut-Off; Safety Interlock Lid To Prevent Opening While Rotor Is Turning • Soft-Touch Lid Closure For Ergonomic Lid Locking — And Releases Automatically At The End Of A Run • Digital Led Display • Noise Level: 49Db; Low-Vibration Operation , Vortex Mixer • Efficient Mixing With Minimal Vibration • Speed Range: 120 To 3200Rpm • Vibration Orbit: 5Mm • Operating Modes: Touch ( Or ) Continuous • Controls: 3-Way Power Switch; Speed Knob: Variable 1–10 Dial Marks • Cup Head For Single Tubes And Platform Suitable For Beakers, Flasks • Can Be Used At 4 To 40 °C ( 85% Relative Humidity, Non Condensing ) , In An Incubator Or Cold Room • Overall Dimensions ( Lxwxh ) : 4.8 X 6.8 X 4.8 In • Electrical ( 50 / 60Hz ) : 120 Volts, 1.2 Amps, 150 Watts • Weight: Around 5 Kg • Vortex Mixer Digital • Efficient Mixing With Minimal Vibration • Speed Range: 120 To 3500Rpm • Vibration Orbit: 3.5 To 5Mm • Microprocessor Controls • 3-Way Power Switch, Led Display For Time / Speed, Up / Down Keys For Set-Point Control • Cup Head For Tubes And Platform Suitable For Beakers, Flasks And Microplates • Operating Modes: Touch ( Or ) Continuous • Electrical ( 50 / 60Hz ) : 120 Volts, 1.2 Amps, 30 Watts , Magnetic Stirrer • Stirring Speed Should Be From 100 Rpm To 1500 Rpm. • Maximum Stirring Volume – 6 Litre. • Plate Temperature Regulation Range - +30 O C To +550O C. • Temperature Uniformity On The Plate - ±3 O C. • Working Plate Heating Time To Reach +300O C – 15 Min. • Maximum Continuous Operation Time – 24 Hour. • Dimension Of Working Plate - 160Cm ×160Cm×10Cm. • Weight – 3Kg • Working Surface Material – Stainless Steel Or Ceramic That Should Be Chemically Resist To Acid And Alkali • Control For Both Hotplate And Stirrer Should Be Provided With Suitable Indicators. • Exact Temperature Setting Via Digital Display ( Led ) , Digital Error Code Display And Elevated Control Panel For Protection Against Leaking Liquids • Automatic Over-Temperature Protection • 230V, 50 / 60Hz • Warranty – 1 Year , Tube Rotator • Variable Speed Tube Rotator With A Small Footprint, Flexible Design, And Simple Display • Accommodates A Variety Of Tubes From 0.5 – 50Ml By Simply Changing The Rotisserie; No Tools Are Required. • Paddles For Different Type Of Tubes ( 10 / 15Ml Paddles; 5Ml / 7Ml Paddles; 1.5Ml / 2Ml Paddles; 50Ml Paddles ) To Be Provided • Mixing Angle Adjusted From 0-90° • 360° Rotation For Thorough Mixing Of All Samples At The Same Time • Rpm: 2-40 • Can Be Used In Incubators And Cold Room Settings • Operating Mode: Continuous / Infinite • Display: Lcd / Led • Ambient Operating Range: 5°C-60°C • Motor Power: 5W • Timing Range: 0-99Min • Power Supply: 220 Volts 50 Hz • Maintenance-Free Motor, Quiet Operation , Digital Dry Bath / Block Heater• Advanced Internal Temperature Sensing Probe For Outstanding Temperature Accuracy And Control • Precise Temperature Control With Pid Circuit • Temperature Calibration Allows The User To Offset The Temperature To Desired Value • Model Should Hold Multiple Heat Blocks At A Time With Interchangeable Aluminum Alloy Heat Blocks For 6X2ml; 6X1.5Ml, 12X0.5Ml And 24X0.2Ml And Pcr Plate Block, 96 Well. • Should Allow For Easy Cleaning And Disinfecting • Powder-Coated Steel Body Construction To Ensure Durability • Built-In Over-Temperature Protection For Sample And User Safety And A Timer • Temperature Range: +5°C To 130°C • Heating Up Time := 25 Min. 30° To 130°C • Temperature Accuracy: = ± 0.5°C • Temperature Uniformity:= ± 1°C • Dimensions ( W X L X H ) , In: 21.1X7.9X3.9; Weight 5Kg • Small Footprint, Lightweight And Ce Certified , Platform / Gel Rocker• High-Capacity Rocker That Is Ideal For Western Blotting And General Mixing Applications. • Microprocessor Control With Adjustable Rocking Speed From 2 To 60 Rpm And Electronic Tilt Angle Adjustment From 0 To 25° • Timer For Up To 2 Hours Or For Continuous Operation. • The Unit Is Safe To Use In Temperature Controlled Environments Up To 70°C • Easy-To-Read, Independent Led Displays For Speed, Tilt Angle And Time • Non-Slip Rubber Pads To Prevent Sample Containers From Moving During Operation • Overload Protection By Activation Of Audible And Visual Signals • Speed Ramping Feature To Slowly Increase Speed To Desired Set-Point • Spill-Resistent Design • Maximum Load Capacity: Upto 5 Kg • Voltage Power: Ac220v, 50 / 60Hz / 6W , 96 Well Horizontal Gel Electrophoresis Unit 1. Cell Size ( Wxlxh ) 21X28x13cm 2. Gel Tray Sizes ( Od ) ( W X L ) 16 X17.5Cm 3.Must Be Suitable For Use In Combination With Two Or More Sample Combs, Ideal For High Throughput Electrophoresis. 4. Small Footprint Area Reduces Uptake Of Bench Space Within Lab.5. Acrylic Buffer Chamber And Safety Cover With 0.012 Inches Diameter Platinum Wired Electrodes. 6. Horizontal Flexi Casters With An Adjustable Barrier To Ensure Efficient Leak Free Casting. An Adjustable Leveling Feet And A Spirit Bubble To Facilitate Even Gel Pouring. 7. Buffer Recirculation Ports To Allow Maintenance Of Uniform Ph And Ionic Strength And Reduce Frequency Of Buffer Changes Necessary During Long Runs. 8. Tight Fitting Acrylic Safety Covers To Reduce Condensation During Electrophoresis. 9. A Coolant System Recirculated Beneath Gel To Provide Constant Temperature Runs. 10. Uv Transparent Gel Trays And Scoops. 11. Leveling Base With Bubble Level 12.The Distance Between The Electrodes Should Be 25Cms , Pocketph Tester With Batteries • Simultaneously Measure Ph And Temperature To Provide Accurate Measurements On The Go • Sensor : Ph- Glass Electrode , Temperature- Thermistor • Ph Measuring Range: -1To 15 Ph; Ph Resolution: 0.1Ph; Ph Accuracy: ±0.1% • 3-Point Calibration To Accurately Measure Ph Across The Acid And Alkali Ranges • Temperature Range: -5 To 60?C; Temperature Accuracy: ±0.6°C; Temperature Resolution: 0.1°C • Simultaneous Display Of Temperature; User Selectable Oc Or Of • Automatictemperaturecorrection / Compensation • Auto Buffer Recognition And Calibration • Battery Life: 250 Hours • Battery Type: 4X 1.5V Micro Alkaline • Display Resolution : Ph – 0.001, Temperature - 0.1?C • Display : 4 Digits, Lcd, Bar Graph Display, 0.8 Seconds / Cycle • Multi Language Operational Instructions • Operating Conditions: 0-45°C, 5 To 85% Humidity In The Absence Of Condensation • Should Provide Colourless Ph Buffer Set, Ph 4.01, 7.00, 10.01 Each Or Ph Buffer Sachet Set, Ph 4.01, 7.00, 10.01 • Should Provide Storage Solution For Ph Sensor, And Solution For Protein Remover And Replacement Sensor Cap • Ce, Fcc Class A Certified , Refrigetrator • Dual Compartments With Independent Compressors. • Automatic Defrost. • Disaster Recovery Safety Control. • Digital Controller Is Provided For Display Of Internal Temperature Along With Alarm Systems. • Capacity – 190 Litre • Temperature Range 0 - 10 O C. • Uniform Cooling By Forced Air Circulation. • Adjustable Plastic Coated Wire Mesh Selves. • Clear Product Visibility With Dual Glass. • High Performance. , Upright Aluminium Freezer Racks • Front Access, Sliding Drawer Type Freezer Rack Made Of Corrosion-Resistant Material With Folded Rails To Reduce Frost • 4X4 Freezer Rack For Storage Of 1 Inch And 2 Inch Standard Size Cryogenic Boxes • Should Fit Most Standard Upright Freezers • Should Be Designed To Reduce Scratching And Enable Easy Removal From The Shelf • Colored Labels For Drawer Sample Identification • Dehumidifier • Portable Digital Dehumidifier With Rolling Casters • Low Temperature Operation Down To 41F • Removes Upto 50 Pints Of Water / Day • Three Fan Speed • Custom Humidity Control • Loss Of Power Protection With Auto Restart • Automatic Defrost • Automatic Shut Off Timer And Full Tank Alert • Options For Continuous Drain Mode • Garden House Connector For Continuous Drainage • Easy-To-Clean Washable Filter • Approximately 11.6 X 15 X 24.4 Inches • Voltage: 115V , Laboratory Coolers • Benchtop Coolers That Hold Standard Tube And Vial Sizes In Various Matrixes And Featuring Labeled Grids For Fast Identification. • Inserts Compatible For0.2 To 2Ml Tubes • Gel Filled / Clear Lid Type • Holding Temperature -20°C For 60 Mins • Made Of Impact-Resistant Polycarbonate With Locking Handle For Long-Term Use • Stackable To Save Space , Automatic Pipette Controller• A Light, Ergonomic, Motorized Pipet Controller Designed For Use With Glass And Plastic Serological Pipets From 0.5 To 100Ml • Autoclavable Pipette Cone • Single Handed Operation With Variable Motor Speed • Separate Aspirate And Dispense Speed Controls For Precise Pipetting • Feature A Heavy-Duty Rechargeable Lithium-Ion Battery • Up To 12 Hours Of Continuous Operation Without Recharge • Direct Exhaust Of Liquid Vapour; With Safety Valve & Dual Hydrophilic, Hydrophobic Filter To Prevent Cross-Contamination. • Replaceable Membrane Filter To Protect Device From Contaminants Being Drawn Into Pipet • Lcd Display For Continuous Visualization Of Speed, Modes, And Battery Status • Can Be Used While It Is Charging , Infusion Pump 1. Capability For Working On Ac Power2. Internal Rechargeable Battery Lasting Over 3 Hours With Full Charge. 3. Capable Of Using50ml Syringe 4. Delivery Rate Should Be From 0.1 Ml / Hr 5. Microprocessor Accuracy Of <+5% 6. Alarms For Occlusion, Near Empty, Low Battery Etc , Pulse Oximeter 1. High Resolution 6.4 Color Tft Display 2. Graded And Color Coded Alarms ( 2 Stages ) 3. Critical Alaram Summary Page 4. 24 Hrs Graphical Trend With Zoom Facility ( Non-Voltive ) 5. Suitable For Adult And Paediatric Applications 6. Optional Thermal Array Recoder 7. Rechargeable Battery Backup 8. Includes: ( Per Set ) 9. Main Unit With Power Cable 10. Spo2 Extension Cable 11. Spo2 Dura Sensor ( Nellcore ) , Digitalph Meter • Perform Easy Measurements And Customizable Four-Meter Channels With Interchangeable Modules • Perform Up To A 6 Point Ph Calibration, Log Up To 2000 Data Point Sets With Time / Date Stamp And Easily Transfer Calibration And Data Logs Via Usb Or Rs232 To A Printer Or Computer • Lcd Display • Temperature Range:-5°C To +105°C; Temperature Accuracy: ±0.1°C; Temperature Resolution 0.1°C • Ph Range: -2 To 20; Ph Accuracy: ±0.002; Ph Resolution: 0.1 • Have Set Point Alarm, High / Low Limit Alarm, Calibration Due Alarm • Numeric Keypads With Menu-Specific Function Keys And Dual Purpose Scroll / Shortcut Keys • Should Come With Ph Electrode Probe, Electrode Stand, 100-240V Universal Power Adapter And Computer Cable • Dimensions ( W X L X H ) , Cm: 28 X 24 X 10; Weight 1Kg • Multi Language Operational Instructions , De-Humidifier Capacity1 90 Ppd Energy Factor1 2.2 L / Kw-H Airflow @ Varying E.S.P. ( External Static Pressure - Dry Coil ) 0.0” W.C.380 Cfm 0.2” W.C.350 Cfm 0.4” W.C.310 Cfm 0.6” W.C.250 Cfm Voltage, Phase, Frequency120v, 1?, 60 Hz Current Draw18.1 A Noise 48 Dba Ducted 54 Dba Unducted Dimensions:Width: 20.75” W / Filter Doors Height: 19.62” Cabinet, 20.62” - 22.62” W / Leveling Feet Length: 24” Cabinet, 29” W / Collars Operating Conditions Inlet Air Operating Conditions Installation 50°F - 105°F, 40° Dew Point Minimum 40°F - 140°F, 0% - 95% Rh ( Non-Condensing ) , Laboratory Timer• Easy Programmable Laboratory Timer • Aaa Alkaline Battery And Chemical-Resistant Abs Plastic Case • Two Or Three - Memory Timer With Digital Display • Accuracy: 0.001% • Resolution: 1 Sec. • Memory Recall • Timer Range: 99 Hours, 59 Minutes, 59 Seconds To 1 Second • Distinct Alarm For Each Channel, 1 Minute, Silenced Automatically Or Manually • Easel Stand, Clip, And Magnetic Back • Dimensions: 2.22L X 6.98W X 5.39Cmh ( 0.875 X 2.75 X 2.125 In. ) • Weight: 1.9 Oz. ( 54G ) . , Power Pack • Output Range ( Programmable ) : 10-300V, Fully Adjustable In 1 V Steps; 4-400Ma, Fully Adjustable In 1 Ma Steps • Type Of Output: Constant Voltage Or Constant Current With Automatic Crossover • 4 Pair Of Jacks In Parallel • Fully Adjustable Timer From 1 Min-99Hr 59 Min • Pause / Resume Function Essential. Automatic Recovery ( After Power Failure ) Eliminates Need To Restart The Unit • Operating Conditions: 0-40°C, 0-95% Humidity In The Absence Of Condensation • Safety Features: No- Load Detection, Sudden Load Change Detection, Overload / Short-Circuit Detection, Over Voltage Protection • Dimensions ( W X L X H ) , Cm / In: 21 X 24.5 X 6.5 / 8.3 X 9.6 X 2.6 • Input Power: 90-120 Or 198-264 Vac, 50 / 60 Hz Auto Switching • 3-Digit Led Display • Weight:1Kg , Digital Water Bath• General Purpose Digitalwater Baths, Designed To Maintain Water Temperature From Ambient To 100°C • Over-Temperature Safety Circuitry • Auto-On And Auto-Off Timers • Audible Alarms Protect Crucial Experiments • Epoxy Powder-Coated Exterior • Stainless Steel Interior • Should Be Provided With Clear Polycarbonate Gable Cover, Diffuser Tray, And Rubber Duck • Monochrome Lcd Display • Heating Capacity 300W • Temperature Range Ambient To100°C • Temperature Stability: ±0.1°C • Temperature Uniformity: ±0.2°C • Smaller Footprint • Ce Certified , Forehead And Ear Digital Infrared Thermometer For Babies And Adults.Technology: It Should Designed Ergonomic And Engineered With Latest Infrared Technology Smart Chips For Optimized Calibration, Probe Sensors Are Highly Accurate In Delivering Instant Readings Within 1 Second .Multi-Mode Measurement: It Should Built With Multiple Temperature Detection Modes, Not Only Supports Ear And Forehead Function, But Also Measures Temperature Of Any Given Object, Liquid Or Room. Suits All Ages: I Should Universally Made To Measure Temperature For Infants & Adults, Apart From Room / Object Temperature, Especially Suits Babies As Reading Can Be Taken Without Disturbing Or Waking Them Safe And Risk Free: Efficient Companion For The Family And Children, The Mute Mode Allows You To Check Temperature Of Toddlers Without Disturbance, Safest Device For Usage As It Is Fda Approved. Indicators: The Thermometer Should Indicates Temperature In Colours ( Green, Orange & Red ) Apart From Displaying The Reading On Lcd Screen With Backlight, Easily Toggle Between °C & °For.Memory: The Device Should Capable To Recall 35 Readings Through Memory Function, So You Can Easily Track Temperature Change When Needed, The Button Is Also Used In Detecting Object / Room Temperature. Service & Warranty: 1 Year Warranty On Manufacturing Defects To Ensure Quality Customer Support , Flammable Safety Cabinets • Material :Mild Steel • Durable & Chemical Resistant, Lead-Free Powder–Coat Paint Finish, Minimizes Effects Of Corrosion & Humidity • Dual Vent With Flame Arrestor • Vent Filtration Box For Removal Of Vapour • Safety Shelves Designed To Safely Direct Incidental Spills To Back & Bottom Of Leak Proof Sump • Door Opening Style: Manual • Numbers Of Adjustable Shelves: 3 • Double-Wall Cabinet Construction With Thickness Of 1.2Mm Steel And 38Mm Air Space. • Continuous Piano Hinge • Provides Smooth Closure • Gross Weight: 145 Kg • Dimension: 17200X1090x460 Mm • Capacity : 45 Gal / 170L , Laboratorymini Centrifuge • Speed: Upto 6000Rpm ; Fixed Speed • Rotor: Fixed Angle • Quick-Release Rotor System And Electronic Brake • Maximum Capacity 6-8 X 1.5Ml & Compatible Adaptors For 2Ml; 0.5Ml And Pcr Strips • Noise Level: 49Db, Low-Vibration Operation • Compact, Rugged Design Withstands Heavy Use In Crowded • Dual Lid Switch For Safe Operation , Pcr Cooler • Easy To Handle, Space Saving And Free Of Contamination • Temperature Of Single Tubes To Be Indicated By The Color Of The Individual Bores • Maintain A Sample Temperature Of 0°C For Over An Hour And Then Change Color When The Temperature Exceeds 7°C • Cooler To Accommodate Individual Tubes, Tubes In A Rack, Tube Strips, Or A 96-Well Plate. , Crash Cart -Overall Size Shall Be More Than 900Mm L X 500Mm W X 1500Mm H. -The Crash Cart Should Be Made Of 25.4Mmx18g Stainless Steel Tubular Frame Work. -Shall Have Epoxy / Anti-Microbial Powder Paint Inside And Out - Should Have Dual Push Handles On Either Side-Should Have S.S. Shelves, Six Colored Removable Bins & Two Polystyrene Lockable Storage Units With Three Drawers Each. -Facility To Carry Ecg Monitors, Defibrillators Etc On Open Areas At Top Centre And Bottom Shelves.-Should Have Stainless Steel Saline Rod Fixed With.-Two Accessory Mounting Brackets To Mount Accessories Anywhere Without The Need Of Pre-Threaded Holes. -Crash Cart Should Be Mounted On 12.5 Cms Dia Non-Rusting Swiveling Castor Wheels. Two Having Locking Arrangement. -Oxygen Cylinder Stand Epoxy Powder Coated, On One Side
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 16
8.
Road Transport and Highways #8873129 Technical Bid
Procurement Of Laboratory Equipments For Material Testing Laboratory Of Iahe - 2 Tests On Soil 3 Unconfined Compressive Strength Ncompression Device With Digital Load Frame: Hydraulic Proving Ring, Dial Gauge Vernier Callipers, Timer, Oven, Weighing Balance 4 Shear Strength Vane Shear Apparatus 5 Grain Size Analysis As Per Is:2720 ( Part- Iv ) Npipette Apparatus ( I ) Sampling Pipette ( Ii ) Glass Sedimentation Tubes ( Iii ) Weighing Bottles ( Iv ) Deleted ( V ) Stirring Apparatus ( Vi ) Sieves -2Mm, 425Umm , 75Umm Is Sieves ( Vii ) Deleted N N 6 Specific Gravity Nhydrometer Apparatus: Two 1000 Ml Graduated Cylinders, Dispersing Agent Solution Containing Sodiumhexa-Metaphosphate, Dessicator And Centimetre Scale. N Nremarks: Water Bath And Balances Have Been Deleted Due To Duplicity N 7 Shrinkage Limit Test Nfull Set Of Equipments 1. ) Evaporating Dish Of Porcelain, 2. ) Spatula And Straight Edge, 3. ) Balance-Sensitive To 0.01 G Minimum.4. ) Shrinkage Dish. Circular, Porcelain Or Non-Corroding Metal Dish, 5. ) Glass Cup. 50-55 Mm In Diameter And 25 Mm In Height, 6. ) Glass Plates. Two, 75X75 Mm One Plate Of Plain Glass And The Other Prongs, 7. ) Thermostatically Controlled Oven, 8. ) Wash Bottle Containing Distilled Water, 9. ) Graduate-Glass, With Capacity Of 25 Ml. 10. ) Mercury. 8 Sand Equivalent Value N ( I ) Graduated Cylinder ( Ii ) Irrigator Tube ( Iii ) Siphon Assembly ( Iv ) Weighted Foot Assembly ( V ) Measuring Can ( Vi ) Sieve -4.75Mm ( Vii ) Funnel ( Viii ) 4- Litre Bottle ( Ix ) Flat Pan ( X ) Timing Device ( Xi ) Sand Equivalent Shaker N N 9 Deleterious Content Of Soil-Organic Ncarbon Content ( I ) Oven ( Ii ) Chemical Balance Sensitive To 0.001Gm ( Ii ) Volumetric Flask -2 Nos. 1 Lt. Capacity ( Iii ) Burette- 2Nos. 2Ml Capacity Graduated -0.1Ml ( Iv ) Pipette- 10Ml Pipette And 1Ml Pipette Fitted With Rubber Teat ( V ) Conical Flask-2Nos-500Ml Each ( Vi ) Graduated Measuring Cylinder -200Ml And 25Ml ( Vii ) Desiccator ( Viii ) Glass Weighing Bottle-Dia 25Mm50mm Height Fitted With Ground Glass Stopper ( Ix ) Sieve- 10Mm Is Sieve ( X ) Wash Bottle N 10 Deleterious Content Of Soil - Total Soluble Sulphate N ( I ) Deleted ( Ii ) Glass Beaker -250Ml ( Iii ) Glass Funnel -50Mm Dia ( Iv ) Glass Bottle -250Ml Capcity With Rubber Cork ( V ) Crucible-50Ml ( Porcelain ) ( Vi ) Pipette-25Ml ( Vii ) Burette -50Ml ( Viii ) Filter Paper- Whatman No-42 ( Ix ) Heating Equipment- Hot Plate 8” Dia ( X ) Deleted ( Xi ) Sieve Shaker ( Xii ) Deleted ( Xiii ) Mortars With Rubber Covered Pestle N Nremarks: Digital Balances, Muffle Furnaces And Oven Have Been Deleted Due To Duplicity 11 Deleterious Content Of Soil -Calcium Carbonate N ( I ) Burette-50Ml ( Ii ) Conical Flask-500Ml ( Iii ) Glass Funnel--75Mm Dia ( Iv ) Filter Paper-Whatman No-40 N 12 Total Soluble Solids N ( I ) Conductivity Meter ( Ii ) Digital Balance 200 Gm-Sensitive To 0.01 Gm ( Iii ) Measuirng Cylinder-50Ml Capacity ( V ) Beaker-150 Ml ( Vi ) Glass Rod Or Stirrer N 13 Ph Test -Electronic Method N ( I ) Ph Meter ( Ii ) Digital Balance 300 Gm Capacity-Sensitive 0.001Gm ( Iii ) 100Ml Glass Beaker -3Nos. ( Iv ) Volumetric Flask-500Ml -Nos. ( V ) Wash Bottle-100 Ml ( Vi ) Mortar With Rubber Covered Pestle N 14 Tests On Aggregates 15 Polished Stone Value ( I ) Accelerated Polish Machine Mounted On Firm , Level And Non Resilient Base Of Stone Or Concrete ( Ii ) Road Wheel ( Iii ) Means For Rotating Road Wheel ( Iv ) Means For Bringing The Surface Of A Rubber-Tyred Wheel Of 20 Cm Diameter And 5 Cm Breadth To Bear On The Stone Surface Of The Road Wheel With A Total Load Of 40 Kg. ( V ) Means To Feed The Sand And Water At A Uniform Rate ( Vi ) Means To Feed The Emery Powder And Water At Uniform Rate ( Vii ) Friction Tester: Is: 2386 Part 4 As Per Specification Of Rrl Uk ( Viii ) 25 Kg Hard Siliceous Sand ( Ix ) Emery Powder 5 Kg 16 Alkali Aggregate Reactivity Nmortar Bar Method: Scales, Weights, Sieves, Glass Graduates, Specimen Moulds, Mixing Bowl, Tamper, Trowel, Containers, Length Comparator N 17 Alkali Aggregate Reactivity Nchemical Method: N1. Electronic Balance N2. Pulveriser N3. Reaction Container, Reagents, Glassware N N N 18 Petrographic Examination N1. Geological Hammer N2. Petrographic Microscope N3. Screen Confirming To Is Sieve N4. Digital Balance N5. Portable Handheld Cutting Machine N6. Hand Lens N7. Glass Sides Etc. N N N N 19 Deleterious Material & Organic Impurities Nsedimentation Pipette: A Watertight Screw-Topped Glass Jar, 1000 Ml Measuring Cylinder, Chemicals, Containers, Sieves N Nremarks: Oven Has Been Deleted Due To Duplicity N 20 Bitumen / Emulsion / Cutback / Bituminous Mixes 21 Distillation N ( I ) Distillation Flask - 500 Ml ( 2 Nos ) , Side Arm ( Ii ) Thermometer 0-200 Degree ( Iii ) Condenser ( Water ) - A 250-Mm Glass-Jacketed Condenser ( Iv ) Adapter - Of Curved Design ( V ) Shield - Of Galvanized Iron, Lined With 3-Mm Asbestos, Fittedwith Transparent Covered Windows ( Vi ) 6 Crow Receivers - Of 25 Ml, 50 Ml Or 100 Ml Size ( Vii ) Residue Container - The Container For The Distillation Residueshall Be A 250 G Metal Container Approximately 76 Mm In Diameter And54 Mm Deep, Provided With A Lid. N 22 Fraass Breaking Point Test N ( I ) Bending Apparatus ( Ii ) Plaque ( Iii ) Cooling Appartus ( Iv ) Thermometer ( V ) Plate And Sand N 23 Solubility Test N ( I ) Gooch Crucible ( Ii ) Conical Glass Flask - Of 200-Ml Capacity ( Iii ) Solvent- Carbon Disulphide, Trichloroethylene N 24 Seperation Test N ( I ) Aluminium Tube ( Ii ) Oven ( Iii ) Freezer ( Iv ) Rack ( V ) Spatula And Hammer N 25 Absolute Viscosity& Kinematic Viscosity N ( I ) Cannon Manning Vacuums Viscometer-2 No. ( Ii ) Cannon Fenske Viscometer-2 No. ( Iii ) Thermometer- 1 No. ( Iv ) Bath- 1 No. ( V ) Vacuum System-1 No. ( Vi ) Timing Device-1 No. N 26 Industrial Viscosity Ntar Viscometer With Set Of Equipments N 27 Rolling Thin Film Oven ( Rtfot ) 28 Particle Charge Tester 29 Storage Stability Tester Nfour 500 Ml Corning Glass Cylinders With Stopper, 50 Ml Siphon Glass Tube Pipette, 1000 Ml Glass Beakers Of Corning Glass And Rod ( 6 ) N 30 Mastic Asphalt Hardness Test Nmastic Asphalt Hardness Tester N 31 Resilient Modulus Of Bituminous Mixtures 32 Theoretical Maximum Specific Gravity N ( I ) Vacuum Bowls— ( Ii ) Vacuum Flask For Weighing In Air Only ( Iii ) Deleted ( Iv ) 3 Vacuum Pump Or Water Aspirator ( V ) Residual Pressure Manometer Or Calibrated Absolute Npressure Gage ( Vi ) Thermometers ( Vii ) Water Bath ( Viii ) Bleeder Valve ( Ix ) Mechanical Agitation Device ( X ) Deleted N N N 33 Bitumen Content By Ignition Method N1. Asphalt Content Tester N N N 34 Bitumen Laboratory Mixer ( 20 Liters ) 35 Dynamic Shear Rheometer Test System 36 Cement 37 Soundness ( Autoclave Apparatus ) Ngraduated Glass Cylinders, Moulds, Autoclave, Length Comparator N 38 Chemical Analysis Test Of Cements Nweight Balance ( 2 Nos. ) N 39 Glassware ( 5 In Nos. ) 40 Bunsen Burner ( 2 In Nos. ) 41 Muffle Furnace ( 2 In Nos. ) 42 Platinum Crucible - Capacity 20 Ml ( 5 In Nos. ) 43 Nickel / Zirconium Crucible - Capacity 20 Ml ( 5 In Nos. ) 44 Compaction ( Mortar Cube Vibrator ) 45 Nfineness ( Blaine Air Permeability Apparatus ) N N 46 Super Plasticiser 47 Super Plasticiser: Dry Material Content Nwide Mouth Glass Bottle ( 60 Mm Diameter, 30 Mm Height ) Provided With Ground Glass Stopper- Birmingham Metals, Bc10 ( 5 In Nos. ) N 48 Ph Meter ( 2 In Nos. ) 49 Water Soluble Chloride: N1. Turbidimeter N2. Reagents N N N 50 Volumetric Flask ( 10 In Nos._ 51 Galvanometer ( 2 In Nos. ) 52 Lime 53 Test For Available Lime As Calcium Oxide ( Full Set Of Equipment ) ( 2 In Nos. ) 54 Test For Available Lime As Calcium Carbonate Nfunnel ( 20 In Nos. ) N 55 50 Ml Flask ( 15 In Nos. ) 56 Leveling Bottle ( 10 In Nos. ) 57 Condenser Tube ( 10 In Nos. ) 58 Water Jacket ( 10 In Nos. ) 59 Compensator Tube ( 10 In Nos. ) 60 Gas Burette ( 20 In Nos. ) 61 Manometer ( 5 In Nos. ) 62 Sodium Hydroxide Bubbler ( 5 In Nos. ) 63 Valve ( 10 In Nos. ) 64 Three-Way Cocks ( 5 In Nos. ) 65 Test For Free Calcium Oxide Apparatus Nplatinum Crucible ( 2 In Nos. ) N 66 Test For Free Lime In Portland Cement Test Nconforming To Is 4032 ( Ethanol Glycerol Method ) 67 Erlenmeyer Flask ( 20 In Nos. ) 68 Desiccators ( 2 In Nos. ) 69 Reflux Condenser 70 Reinforcing Bar ( Steel ) 71 Chemical Tests Of Steel Ncarbon % Noxygen Cylinder And Purifier, Furnace With Combustion Tube, Train For Purifying And Absorbing Carbon Dioxide N 72 Chemical Tests Of Steel Nsulphur % Ncomplete Apparatus As Per Is 228 ( Part 9 ) N 73 Chemical Tests Of Steel Nphosphorus % Ncomplete Apparatus As Per Is 228 ( Part 3 ) N 74 Reinforcing Bar ( Steel ) Nto Determine Unit Weight, Yield Strength, , Proof Stress, Ultimate Tensile Strength, % Elongation, Bend And Re-Bend Test N N N 75 Concrete Test Equipment 76 Vibrating Table 1Mx1m 77 Needle Vibrator ( 2 In Nos. ) 78 Permeability 79 Dry Shrinkage ( Shrinkage Apparatus ) ( 2 In Nos. ) 80 Air Content ( Air Entrainment Meter Apparatus ) 81 Durability ( Rapid Chloride Ion Permissibility Apparatus ) 82 Depth Of Penetration ( Water Permeability Apparatus ) ( 2 In Nos. ) 83 Pavement 84 Structural Evaluation Of Pavement Nfalling Weight Deflectometer 85 Water 86 Chemical Analysis Of Water N N 87 Physical Analysis Of Water N N N 88 Geo Textile And Geogrid 89 Npull-Out Resistance Of Geotextile / Geogrid N 90 Ndt 91 Pull-Out Test N Npull-Off Tester Unit; Battery Pack; Battery Charger With Usb-Cable; Test Disc Aluminum Ø 50Mm / M10 – 100 Nos.; Draw Bolt M10; Torx Screwdriver; Software, Operating Instructions, Certificate Of Conformity And Carrying Case. N 92 Reinforcement Corrosion ( Half-Cell Potential Measurements Apparatus ) 93 Homogeneity & Quality Test ( Ultrasonic Pulse Velocity Apparatus ) 94 Compressive Strength ( Schmidt / Rebound Hammer Apparatus ) 95 Cover Meter Test 96 Epoxy 97 Viscosity Test Nfull Set Of Equipment N 98 Pot Life Nfull Set Of Equipment N 99 Bond Strength Test Nfull Set Of Equipment N 100 Shear Strength Nfull Set Of Equipment N 101 Ht Strands 102 Luminance Test Night Visibility ( Rl ) And Day Visibility ( Qd ) , Retro Reflectivity Of Road Markings Nretroreflectometer For Road Markings N 103 Thickness Test For Thermo Plastic Road Markings ( 2 In Nos. ) 104 Co-Efficient Of Retro-Reflection Test Of Retro Relfective Sheeting, Retro-Reflective Sign & Boards Sheeting Nretroreflectometer For Signages N 105 Metal Beam Crash Barriers 106 Stripping Test ( Zinc Coating Apparatus ) ( 2 In Nos. ) 107 Thickness Gauge Test ( 2 In Nos. )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
9.
Defence #8195446 AOC
Tender For Cleaning Sanitizing Maintenance Of Oh Tanks Reservoirs Ug Sumps Swimming Pool Filtration Plant And Other Connected Works Under Ge Narangi.; 1 Material and labourfor seven stage cleaning and sterilization of insideof overhead RCC tank atC block MD Accn Area of capacity 2.00 Lakh Gallon through bacteriological treatment by using chemical as approved byE-in-cs Branch or as recommended by GE and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed. Seven stages are as under follows :-(a)First stage is to drain out the water by using exit valve orown high capacity dewatering ststem.(b) Second stage is cleaning all the algae fromation inside the tank by using approved chemical as recommended by GE including scrubbing the walls of the tank.(c)Third stage is scrubbing the wall with mechanical scrubber and fresh water cleaning by high speed jet pump (rotary & flat) to remove all scalling, algae and other formed particles on internal surface of the tank completely. (d)Forth stage and first bacteria screening is sterilization by using approved chemical as recommended by GE.(e) Fifth stage is cleaning the floor of the water tank by heavy duty industrial vacuum cleaner and sludge sucker having maximum 1200W with sutable heavy duty rugged motor to free of any foreign and loose particles on any nature.(f)Sixth stage is the second bacteria screening and sterilizing method by usingultra violet ray by heavy duty UV radiation which shall havecovering 360 degree of sterilization withthe tank to kill all suspended bacteria.(g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor and wall of the water tank by using oxidizing agent Bleaching powder or equivalent non- toxic bio- degradable eco friendly anti bacterial agent certified by Govt approved laboratory to disinfect the over head tank from all harmful pathogens complete all as specified and directed . 2 All as per item No. 1 Above but atB block MD Accn area ( Havalder Pump House),of capacity 1.00 Lakh gallon. 3 All as per item No. 1Above but atB block MD Accn area ( Havalder Pump House) & 14 FAD OTM of capacity 0.50 Lakh gallon. 4 All as per item No. 1Above but at Jintu Vihar MD Accn areaof capacity1.00 Lakh gallon. 5 All as per item No. 1 Above but atPhase-II MD Accn areaof capacity 1.00 Lakh gallon. 6 All as per item No. 1Above but at17 CZW areaof capacity 1.00 Lakh gallon 7 All as per item No. 1Above but atPhase-II MD Accn area & 222 ABOD OTM of capacity upto 0.25 Lakh gallon. 8 All as per item No. 1 Above but atABOD OTM Accn areaof capacity 1.00 Lakh gallon. 9 Material and labourfor seven stage cleaning and sterilization of insideof overhead pressed steel tank at Ph-II MD Accn Area of capacity 0.75 Lakh Gallon through bacteriological treatment by using chemical as approved byE-in-cs Branch or as recommended by GE and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed. Seven stages are as under follows :-(a)First stage is to drain out the water by using exit valve orown high capacity dewatering ststem.(b) Second stage is cleaning all the algae fromation inside the tank by using approved chemical as recommended by GE including scrubbing the walls of the tank.(c)Third stage is scrubbing the wall with mechanical scrubber and fresh water cleaning by high speed jet pump (rotary & flat) to remove all scalling, algae and other formed particles on internal surface of the tank completely. (d)Forth stage and first bacteria screening is sterilization by using approved chemical as recommended by GE.(e) Fifth stage is cleaning the floor of the water tank by heavy duty industrial vacuum cleaner and sludge sucker having maximum 1200W with sutable heavy duty rugged motor to free of any foreign and loose particles on any nature.(f)Sixth stage is the second bacteria screening and sterilizing method by usingultra violet ray by heavy duty UV radiation which shall havecovering 360 degree of sterilization withthe tank to kill all suspended bacteria.(g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor and wall of the water tank by using oxidizing agent Bleaching powder or equivalent non- toxic bio- degradable eco friendly anti bacterial agent certified by Govt approved laboratory to disinfect the over head tank from all harmful pathogens complete all as specified and directed . 10 All as per item No. 9Above but at 41 Veh Coy of capacity 0.072 Lakh gallon capacity. 11 All as per item No. 9Above but attarapore Enclave area of capacity 0.50 Lakh gallon. 12 All as per item No. 9Above but atPeer Baba colony area of capacity 0.072 Lakh gallon. 13 All as per item No. 9Above but atShopping Complex area of capacity 0.168 Lakh gallon. 14 All as per item No.9Above but atADG Complex area of capacity 1.00 Lakh gallon. 15 All as per item No 9 Above but atC block MD Accn area area of capacity 2.00 Lakh gallon. 16 All as per item No. 9 Above but atJorabat Colony of capacity 0.072 Lakh gallon. 17 Material and labourfor seven stage cleaning and sterilization of insideof Semi underground sump of capacity 0.20 Lakh gallon capacity at Jorabat Colony pump house , 41 Veh Coy Pump house, Peerbaba colony pump house and 1 ABW Madhuban Officers Mess through bacteriological treatment by using chemical as approved byE-in-cs Branch and as recommended by GE and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed. Seven stages are as under follows :-(a)First stage is to drain out the water by using exit valve orown high capacity dewatering ststem.(b) Second stage is cleaning all the algae fromation inside the tank by using approved chemical as recommended by GE including scrubbing the walls of the tank.(c)Third stage is scrubbing the wall with mechanical scrubber and fresh water cleaning by high speed jet pump (rotary & flat) to remove all scalling, algae and other formed particles on internal surface of the tank completely. (d)Forth stage and first bacteria screening is sterilization by using approved chemical as recommended by GE.(e) Fifth stage is cleaning the floor of the water tank by heavy duty industrial vacuum cleaner and sludge sucker having maximum 1200W with sutable heavy duty rugged motor to free of any foreign and loose particles on any nature.(f)Sixth stage is the second bacteria screening and sterilizing method by usingultra violet ray by heavy duty UV radiation which shall havecovering 360 degree of sterilization withthe tank to kill all suspended bacteria.(g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor and wall of the water tank by using oxidizing agent Bleaching powder or equivalent non- toxic bio- degradable eco friendly anti bacterial agent certified by Govt approved laboratory to disinfect the over head tank from all harmful pathogens. Complete all as specified and directed. 18 All as per item No 17above but of capacity 1.00 Lakh gallon at New Havalder pump house 19 All as per item No 17above but of capacity 3 x 1.5 Lakh gallon at Main pump house Reservior Tank. Note : 1.5 LG Tank to be measured as one job. 20 All as per item No 17 above but of capacity 1.50 Lakh gallon at Main pump house (Circular Intake sump). 21 All as per item No 17above but of capacity 0.50 Lakh gallon at Hav pump house (Old) and 1 ABW Madhuban Officers Mess 22 All as per Item No.17 above but for Semi-UG Sumps at Swimming Pool Pump House capacity 0.5 Lakh Gallon. 23 Material and labourfor seven stage cleaning and sterilization of insideof2X semi underground sumps at water filtration plant of capacity 0.50 Lakh gallon of each semiundergroundsump atE Block pump housethrough bacteriological treatment by using chemical as approved byE-in-cs Branch and or as recommended by GE and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed. Seven stages are as under follows :-(a)First stage is to drain out the water by using exit valve orown high capacity dewatering ststem.(b) Second stage is cleaning all the algae fromation inside the tank by usingE-in-cs Branch approved chemical as recommended by GE including scrubbing the walls of the tank..(c)Third stage is scrubbing the wall with mechanical scrubber and fresh water cleaning by high speed jet pump (rotary & flat) to remove all scalling, algae and other formed particles on internal surface of the tank completely. (d)Forth stage and first bacteria screening is sterilization by using E-in-cs Branch approved chemical as recommended by GE.(e) Fifth stage is cleaning the floor of the water tank by heavy duty industrial vacuum cleane rand sludge sucker having maximum 1200W with sutable heavy duty rugged motor to free of any foreign and loose particles on any nature.(f)Sixth stage is the second bacteria screening and sterilizing method by usingultra violet ray by heavy duty UV radiation which shall havecovering 360 degree of sterilization withthe tank to kill all suspended bacteria.(g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor and wall of the water tank by using oxidizing agent terbac G65/ Sodium Peraoxide or equivalent non- toxic bio- degradable eco friendly anti bacterial agent certified by Govt approved laboratory to disinfect the over head tank from all harmful pathogens complete all as specified and directed.(Note : cleaning of2x Semi UG sump of capacity 0.50 LGis considered as one job)Note for item No. 1 To 23 :(a) The cleaning will be done as per mechanised seven stage process and results will be verified by the competant authority. (b) The notice for the interruption of water supply shall be intimated to the concerned Engineer In Charge prior to execution of the work and and the process shall be completed within 24 hours of begining the work to avoid inconvenience of water supply in the effected areas. In case the contractor fails to complete the complete cleaning process and resuming the water suooly within 24 Hours , panel recovery of Rs 5000.00 per day will be recovered for the job effected forwhich the contractor shalll not have any extra claim whatsoever from the Dept.. (c)The unit rates quoted by the contractor shall be deemed to be inclusive of Writing date of cleaning in white letters of size as directed on black background. 24 All as per Item No. 23 above but for Water Treatment plant capacity 9 MLD consisting of 06 Nos Sumps, 04 Nos Filtration beds, 02 Nos Intake tanks, raw water passing drains, Treated water collection tanks - 04 Nos, Sludge/back washing drains approx 60RM.The job also include two coat of synthetic enamel painting of pipe lines, gear boxex, MS mixersincude valves of various sizes and white wash of filters beds in a interval of 3 months complete all as specified and directed . 25 Material and labour for comprehensive cleaning of B Block Natural Water Resource and FAD Natural Water Resource of approx 1.0 lakh litres by complete washing out of old settled muddy sand, soil mixture (sludge) etc and removal of settled sludge to a suitable distance not exc. 50mtr complete all as specified and as directed. The rate includes cleaning of pipe lines of approx distance of 1KM from pump house each side include one coat of lime white wash complete all as specified and directed. (Note : 1.Cleaning of one Natural resource be considered as one job . 2. Cleaning of Natural resources be carried out as per requirement on urgent basis). 26 Material and labour for comprehensive cleaning of swimming pool of size 50m X 21m (Olympic Size with Diving Zone)metres situated near Rhino Shopping Complex by complete washing out of old settled water including scrapping off the old surfaces using wire brush/stainless steel wiper etc and removal of settled sludge to a suitable distance all as directed at site and cleaning of entire swimming pool by using bleaching powder, tiles cleaning chemicals, detergent and wiping off residual waste water through the drain out chamberincluding sun drying complete all as specified and as directed.(Note: The work shall be carried out by the contractor after seasonal closure of swimming pool) 27 All as per item No 26 here-in-before but for Swimming Diving Pool of size 15m X 15m. 28 Material and labourfor lifting of submersible non clogging pump set from sewage well including dismantling all connections and keeping aside for reinstalling after comprehensive cleaning of sewage treatment plant reservoirs at Phase-II area such as collection cum equalization tank, CC tank, tube settler tank and clear water sump by dewatering and removal of existing sludge from various chambers and scrapping off after draining out waste/sludge and depositing to a suitable location as directed at site, cleaning of all reservoirs mentioned above using bleaching powder and wire brush and wiping off properly including sun drying before re commissioning at site complete all as specified and as directed. Note: Proper shut down shall be taken before commencement of subject work 29 Taking out old UNSV MS Angle/ channel/ Sheet from Open well & Jack well sumps and supply and fabricated MS Covers from 50x50x6mm thck MS Angle Iron frame, MS sheet of size 3mm thick, MS rods, (Fe.290.Gde-E-165) include handle for lifting completeinclude painting with one coat of Red oxide paintand two coat of synthetic enamel paint as per existing size complete all as specified and directed. (Note : Job include cutting corroded structure by welding, fabrication of new structure by welding, cutting and fixing with suitable arrangements). 30 Taking out Old UNSV MS level gauge and supply aqnd fix new MS level gauge of same length as existing having marking of levels at various intervals with bold letters so that it is visible from distance.The work include fixing the gauge by welding , painting and connected assy such as level indicator, float ball, SWR rope and fixing level in floor of UG sump of2 Mtr height complete all as specified and directed. 31 Taking out suction pipe of 150mm bore with defective CI foot valve of 100 mm dia for replacement of the foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe/MS Pipe and lowering in the sump complete all as specified and as directed. 32 Taking out suction pipe of 150mm bore with defective CI foot valve of 150 mm dia for replacement of the foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe/MS Pipe and lowering in the sump complete all as specified and as directed. 33 Taking out suction pipe of 200mm bore with defective CI foot valveof 200 mm dia for replacement of the foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe/MS Pipe and lowering in the sump complete all as specified and as directed. 34 Supply and fixing in repair 100 mm bore CI non-return sluice valve, heavy duty, ISI marked (IS 5312), flanged end including rubber gasket joints, nuts, bolts etc including testing complete all as specified and as directed. 35 Supply and fixing in repair 150 mm bore CI non-return sluice valve, heavy duty, ISI marked (IS 5312), flanged end including rubber gasket joints, nuts, bolts etc including testing ccomplete all as specified and as directed. 36 Material and labour labour for painting of MS structure of of PSS tank of capacity 0.10 LG from outside tank all sides including MS staging upto height of 20 Mtr height having, MS structure, MS/CI/DI Pipe lines inlet/outlet/overflow include fittings and various type of valve as per colour code in 41 Veh coy complete from ground level to tank including one coat of red oxide primer, one under coat and one finishing coat of synthetic enamel paint of Sky Blue colour complete all as specified and directed .. 37 Material and labour for complete cleaning of inside surface of Pressed steel tank (over a height of approx 20 mtr) with wire brush (including hammering, sand blasting to remove heavy rust) removing of mild scale and rust by application of rust removing chemical by brush and leave the surface to react for 15-30 Mins.Then the rusty surface will change their colour.After that remove the loose particles of rust by wire brush complete all as specified and directed.Make:- Sika Rustoff 100 or equivalent in Pidilite/ FOSROC 38 Material and labour for one coat food grade epoxy based Zinc rich corrosion protection primer by stirring the hardner and resin individually with mechanized strirrer of proper size.Then add the entire content of the hardner into Resin container and stir the two components throughly using a low speed mixer for about 2 to 3 minutes until a uniform colour of the mixture is obtained.One coat of 100 micron need to be applied on total inside steel surface and external surface where needed complete all as specified and directed. Make:- Sika Friazinc R or equivalent in Pidilite/ FOSROC) 39 Material and labour for coating with foodgrade coaltar epoxy resin (two part reaction hardening chemical resistant coating of low solvent content based on coal tar epoxy resin in combination with mineral fillers)after through mixing of a base and hardner, the mixed material is applied on the steel surface including second coat where it is needed.Since the pot-life is very short, application must be done very quickly (Inside of tank application only). complete all as specified and directed.Make:-Sika Interol poxitar or equivalent in Pidilite/ FOSROC) 40 Material and labour for removal of old inter panel sealant and use a solvent free two component epoxy resin, mixing the component A and Bat recommended ratio and prepare the sealing material and use it in between the jointing panel as sealant to assure all the interplate joints are sealed in appropriate manner complete all as specified and directed.Make:- Sika Guard 694F (I) or equivalent in Pidilite/ FOSROC) 41 Material and labour labour for preparation of existing painted surfaces, painting of RCC structure of of RCC OH tank of capacity 2.0 LG in C block MD Accn area from outside tank including MS staging upto height of 24 Mtr heightas exixting having, RCC structure, MS structure, MS/CI/DI Pipe lines inlet/outlet/overflow include fittings and various type of valve as per colour code complete from ground level to tank includingone under coat and one finishing coat of weather coat paint ofexisting colur or as directed by Engineer-in-chargecomplete include marking arrows all as specified and directed by Engr-in-Charge. Note : Contractor will approve colour schemes to be approved before start painting works complete all as specified and directed . 42 All as per item No. 41 Above but atB block MD Accn ( Havalder Pump House), Jintu Vihar MD Accn area,17 CZW , Phase-II MD Accn,ABOD OTM Accn area of capacity 1.00 Lakh gallon. 43 All as per item No. 41 Above but atJintu Vihar MD Accn area,of capacity 1.00 Lakh gallon. 44 All as per item No.41Above but atB block MD Accn area ( Havalder Pump House) of capacity 0.50 Lakh gallon. 45 All as per item No. 41 Above but at areaof capacity 0.25 Lakh gallon. Note for item No. 1To 45:(a) The cleaning will be done as per mechanised seven stage process and results will be verified by the competant authority. (b) The notice for the interruption of water supply shall be intimated to the concerned Engineer In Charge prior to execution of the work and and the process shall be completed within 24 hours of begining the work to avoid inconvenience of water supply in the effected areas. In case the contractor fails to complete the complete cleaning process and resuming the water supoly within 24 Hours , panel recovery ofRs 5000.00 per day will be recovered for the job effected forwhich the contractor shalll not have any extra claim whatsoever from the Dept. (c)The unit rates quoted by the contractor shall be deemed to be inclusive of Writing date of cleaning in white letters of size as directed on black background.(d) Rates include T&P and staging requiredfor the job in the quoted rates against BOQ items nothing extra not to be paid on this account.(e)Necessary saffety equipments, saffety measure should be strictly maintained by the persons employed in the work during execution of work as per norms or as directed or required at site during execution of work.Competent person should be present during execution of work. (f) All waste material/ sludge /mud/ muddy sand retrieved after repair/ cleaning worksto be removing from site and dispossed off in low lying area out side the cantt.Rates of transportation to be included in the quoted rates. If contractor fails to doing the job a panel recovery of Rs 3000.00 will be recovered from the job effected forwhich the contractor shalll not have any extra claim whatsoever from the Dept.. 46 Material and labour for scrapping , hammering, chseling scrubbing to surfaces of tank at any height using electric/mechenical means, hand brush blower, etc as recommended by the manufacturer and disposal of all unserviceable complete upto a distance n exc 50 m complete all as specified and directed . 47 Material and labour for applying two coats of hygienic coating of inner walls & floors/bottoms of OHT/UG Sumps using 2 parts, solvent free epoxy resin coating for lining and potable water structure having 100% solid contents, approved by CFTRI(USFDA-175, 300) and complies to ASTM D 2370, etc non toxic cured film meets requirement as per IS 9883 : 1981, Coating to be applied after proper surface preparation to remove loose dust, dirt etc.cleaning , mixing cement in ratio as per OEM instruction by using slow speed electric drill and application of 2 coats at 200 microns DFT complete as per specification and as directed by Engineer in charge. Make : Thermax Ltd, Trimurti (India), Tikitar Danosa (Pvt) Ltd/ Sikka/Pidilite 48 Material and labour for preparation of existing painted surfaces of IRPs of capacity 6000 GPH installed at various locations by applying two coat of synthetic enamel paint to outside surfaces of water lines, inlet and out, overflow pipes of inlet & outlet of pumping linesas per colour code include support structure, fitting & valves, include replacement of flexible pipes of same size complete include marking flow arrow with white synthetic enamel paint complete all as specified and directed. 49 Surface dressing not exc 15cm deep including cleaning away all grass vefetation, saplings, shrubs, brushwood, under growth, rooth , levelling & spreading water and removing rubbish, accumulated sand/mud/wastage up to a distance 200 mtrs outside the periphery of the area under clearance complete all as specified and directed. 50 Material and labour for complete removal of painton newely plastered or old unplastered surfaces including preperation of surfaces by Scrubbing, cleaning the exterior surface of Semi UGreservoir of various capacity and applying two coats of cement base paint on the outer surfaces of height up to 3 meter as existing in various Pump Houses include marking tank cleaning and other details base with black paint over white colour by synthetic enamel paint complete all as specified and directed. 51 Material and labour for cement concrete 1:3:6 type C-2,(using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed. 52 Material and labour for cement concrete1:2:4 type B-1,(using 20 mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed. 53 Material and labour for rendering 10mm thick cement plaster in cement mortar 1:4 on fair faces of brick or concrete surfaces, water line support pillar and three coat of white wash andinclude taking down old complete all as specified and directed . 54 Material and labour for writing the letters TANK CAP ____ LG as specified andSAVE WATERon the tank having uo to height of upto 24 mtr staging with white synthetic enamel painton front side and MES on other side.Size of letter not less than 40 CMs complete all as specified and directed . 55 Taking down old UNSV and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 sqmm including fixing arrangement with OH Tank complete all as specified and directed. 56 Material and labour for preparation of existing painted surfaces of CI/DI/MS pipe line and applying two coat of synthetic enamel paint to outside surfaces of water lines, inlet and out, overflow pipes of inlet & outlet of pumping linesas per colour code include support structure, fitting & valves complete of sizes 300 mm dia pipe complete include marking flow arrow with white synthetic enamel paint complete all as specified and directed . 57 Ditto but of size 200mm bore 58 Ditto but of size 150mm bore 59 Ditto but of size 100mm bore 60 Ditto but of size 50mm to 80mm bore Note for item No. 1To 60:(a) The cleaning will be done as per mechanised seven stage process and results will be verified by the competant authority. (b) The notice for the interruption of water supply shall be intimated to the concerned Engineer In Charge prior to execution of the work and and the process shall be completed within 24 hours of begining the work to avoid inconvenience of water supply in the effected areas. In case the contractor fails to complete the complete cleaning process and resuming the water supoly within 24 Hours , panel recovery of Rs 5000.00 per day will be recovered for the job effected forwhich the contractor shalll not have any extra claim whatsoever from the Dept.(c)The unit rates quoted by the contractor shall be deemed to be inclusive of Writing date of cleaning in white letters of size as directed on black background.(d) Rates include T&P and staging requiredfor the job in the quoted rates against BOQ items nothing extra not to be paid on this account.(e)Necessary saffety equipments, saffety measure should be strictly maintained by the persons employed in the work during execution of work as per norms or as directed or required at site during execution of work.Competent person should be present during execution of work. (f) The complete work will be carried by or in persons supervision of M/s Rays Cleantech/M/s M L Treatment/ M/s MS Tank Cleaning Pvt Ltd or other professional agency for doing such type of work and after completion of work necessary testing certification be obtain by them by the contractor rates to be included in the quoted rates.(g) All waste material/ sludge /mud/ muddy sand retrieved after repair/ cleaning worksto be removing from site and dispossed off in low lying area out side the cantt.Rates of transportation to be included in the quoted rates. If contractor fails to doing the job a panel recovery of Rs 3000.00 will be recovered from the job effected forwhich the contractor shalll not have any extra claim whatsoever from the Dept.. 61 Material and labour for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50Mtr below ground level.The earth plate to be connetced with earth strip 25×4mm thick galvanised iron or steel wire all as shown in para no 4 the earthing test pointall as specified and directd. The GI earthing stripto be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with40mm dia HDPE pipe up to test point. Earthing shall be include withproviding funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth platefurther filled with60 cm thick Tibba sandand 2nd layer with30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layerwithtibba sand up to the ground level. Earthing shall also be include for providingconcrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work 62 Taking down old UNSV light fittings andsupply and fixing LED flood light 100watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant include MS bracket , nuts & bolts fixed on wall or OHT pillar, or MS Structure complete with driver and lamp complete all as specified and directed. 63 Material and labour for earth continuity conductor or main earthing lead for down conductor fixed to wall on porceline insulators/saddle/PVC saddle or on button or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to bldg/roof/pole or any other etc as required aluminium strip of size 25 x 3.15mm include screws, nuts & bolts complete all as specified and directed. 64 Material and labour for GI pipe medium grade40 mm dia with socket at one end in the length of 1.2mtr for supporting of air termination rod or protection of earth conitnuity strip. 65 Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm longhex. head screw complete. 66 Supply and fix in repair thermoplastic ( Polycarbonate) junction box for test point without terminal block of dimension 130x180x77mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for outdoor installation completeall as specified and as directed. 67 Taking down UNSV and supply and fix air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. 68 Material and labour for taking out existing filter media from factory fabricated Multi Grade IRPs/sand filter (as per IS:2825) .Filter shall be provided with inlet, outlet pressure gauge,sample cocks, charge of filter media graded sand and internals consisting of strainer fitted on plate for collection. cylindrical shape mild steel construction, Dia of vessel 2400x 2000(H) ,Operating Pressure 1 to 2 kg/sqcm,capacity 6000 LPHtreatment plant of any description carefully and removing out to distance 50 Mtrs away from installations, including cleaning, washing inside of filter including painting Inside, replacement of UNSV PVC threaded hose pipe, rubber washers, Nuts & Bolts , testing and commissioning complete all as specified and directed. 69 Supply and fix and levelling gravel of size 20 x 12mm thickness as per OEM design for forming media filter of filter beds/bio filter complete all as specified andas directed . 70 Supply and fix and levelling gravel of size 12 x 6mm thickness as per OEM design for forming media filter of filter beds/filter complete all as specified andas directed. 71 Supply and fix and levelling gravel of size 6 x 3mm thickness as per OEM design for forming media filter of filter beds/filter complete all as specified andas directed . 72 Supply and fix and levelling gravel of size 3 x 1.5mm thickness as per OEM design for forming media filter of filter beds/ filter complete all as specified andas directed . 73 Supply and fix and levelling ferrimenix (MNO2) compound as per OEM design complete all as specified and directed. 74 Supply and fix and levelling Activated carbon (Arthritic coal) as per OEM design for forming media filter of filter complete all as specified andas directed . 75 Supply and fix and levelling fine sand of size 0.45mm to 1mmas per OEM design for forming media filter of filter beds/bio filter complete all as specified andas directed .
Contract Date: Oct 31, 2025 Contract Value : 38.12 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
10.
Tourism #8048883 AOC
Providing Additional Tourism Facility At Mtdc Resort Navegaon Bandh Dist Gondia=1 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and fixing in position TMT - FE 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. First Floor Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete First Floor Providing internal cement plaster 12mm thick in single coat in cement mortar 1: without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete First Floor Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete(Low VOC). First Floor Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint). First Floor Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. First Floor Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1: cement mortar including neat cement float, filling joints, curing and clearing etc. complete. First Floor Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 4 cement mortar including neat cement float, filling joints, curing and clearing etc.complete First Floor Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. First Floor Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. First Floor Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. First Floor Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Providing and fixing of factory made uPVC Sliding window & door (White Colour) 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 P Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for period of ten (10) years against nonuniform discoloration, wrapping and rotting under general use. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size x 47 mm. First Floor Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985- 2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 P Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size67 x 78 mm. First Floor Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete First Floor Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete First Floor Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. First Floor Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. First Floor Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. First Floor Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. First Floor Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) First Floor Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. First Floor Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm WithR.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover medium duty 100Kilogrametc. complete. First Floor Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete First Floor Providing and fixing European type wallhung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. First Floor Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. First Floor Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. First Floor Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. First Floor Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. First Floor Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. First Floor Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. First Floor Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. First Floor Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete First Floor Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. First Floor Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) First Floor Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. First Floor Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. First Floor Providing & fixing tera felt APP ( Atactic Poly-prolene) Gobain make underlay membrane of approximate 2mm thick below single fixed by sufficient rust free nails on existing concrete plain/ slopping roof including all materials, transportation, labour and scaffolding etc. complete as per instructions of engineer incharge/ Architect etc. complete. First Floor Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. First Floor Providing & fixing tera felt APP ( Atactic Poly-prolene) Gobain make underlay membrane of approximate 2mm thick below single fixed by sufficient rust free nails on existing concrete plain/ slopping roof including all materials, transportation, labour and scaffolding etc. complete as per instructions of engineer incharge/ Architect etc. complete. First Floor Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper. Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings finishing with french-polish/ waxing complete. (without door frame).(Sample to got approved from Ex.Engineer before use) Commercial Hard Wood shutter Providing and fixing 30mm thick SOLID PANEL PVC INTERNAL DOOR SHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for stiles ,top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat molded PVC channel of size 30 x 100mm forming stiles, and 5mm thick, 125mm wide PVC sheets for top rail, lock rail and bottom rail on either side, and 15mm (5mm x 3) thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 10 mm thick prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent cement adhesive. including stainless steel fixtures and fastening Complete as per direction of Engineerincharge,manufacturersspecification and drawing. Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete Prior approval of sample and brand by Ex.Engineer is necessary before use) Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer. Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. Providing and fixing Puff Sheets of 30 mm thick; colour as per direction and composed of Two side Polyurethane Galvanized Iron sheets of 0.50 mm thick corrugated roofing sheet and Puff Material sandwiched between tow metal sheets profiled sheets for roofing. Of Density of 40 Kg/m^2. Including all types accessories required for proper installation such as External ridge, Internal Ridge, Roof End Cap, Gutters etc. complete Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. Providing and laying in trenches 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 5.17 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Providing and laying in trenches 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 12.43 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti- corrosive oil paint , 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Excavation for foundation in earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directed etc. complete. ( By /manaual Means ) a) Upto 1.50m lift Normal Rate b) 1.50m to 3.00m lift, Add 10% c) 3.00m to 4.50m lift, Add 20% d) 4.50m to 6.0m lift, Add 30% Providing and laying in situ / ready mix / ready mix M10 cement concrete of trap/ granite/ quartzite/ gneiss metal in foundation including necessary centering, formwork, bailing out water, compacting and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with natural artifical sand) Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from departmental Land) Providing dry rubble stone pitching 23 cm about 9 ) thick including all material, quarry spalls, labour etc. complete. Providing vee pointing with cement mortar 1:3 for stone / Brick masonry including scaffolding and curing etc. complete CARPET : Supplying & fixing CONDOR - SAFIER or I.T.C.- QUARTZ or equivalent make synthetic loop pile carpet of approved shade and design with 10mm thk PVC foam underlay laid as per site requirement with side edge stitching clips etc. complete as per instructions of the Architect / Engineer. 5 X Providing & fixing good quality Main curtain of fabric ranging at the Rmt with proper lining inside and stitching as per American plate including providing Curtain Rod hooks elastics etc. complete in all respect as directed by EIC. First Floor Providing ,Supplying and fixing the wall paper on walls or on ply etc of suitable size shall match the size of wall or as per the approved drawings ( joints of paper should be avoided ).The quality of wall paper should be non oven backing with mat & glossy finish.The Paper should be of German technology make and should be quality product.The wall paper and pesting material (glue) should be got approved before fixing by engineer incharge/Architect. For fixing the wall paper necessary base of wall or ply etc should be prepared ,then fix the wall paper in such a way that there should not be any air bubble or undulations seen on the surface of paper as per approved design and drawings and as directed by Engineer incharge/Architect etc complete. First Floor Providing and placing ( 90 cm x 60 cm)posters/portrait/painting of local and other artist to match the interior and surrouding locality including fixing and placing in position etc complete.Colour and designe approved by Engineering in charge etc complete.Specification as Directed by Engineer-in-charge etc,complete. PP ( 90 cm x 60 cm)posters/portrait/painting First Floor Providing and placing ( 45 cm x 30cm)posters/portrait/painting of local and other artist to match the interior and surrouding locality including fixing and placing in position etc complete.Colour and designe approved by Engineering in charge etc complete.Specification as Directed by Engineer-in-charge etc,complete. PP ( 90 cm x 60 cm)posters/portrait/painting First Floor Providing and fixing Mirror with frame, 5mm float glass of Saint Gobain with all necessary beeding , fixtures accessaries and fill up the gaps between glass and frame with sealent and as per drawing approved by Architect and as directed by Engineer in-charge. First Floor Designing , Itching and Buffing on glass as per drawing approved by Architect and as directed by Engineer incharge. First Floor Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels above the fabricated frame on one side , as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete First Floor Providing and fixing Shandelier JES-CHRCHL0006RPE14 6LT Smoky Glass with Crystal ,Lamp:-E-14 LED 4W x 6 of Size:- Depth 700 mm , Height 1300 mmwith necessary scaffolding as per design approved by Architect SOFA : Provide sofa made of 600mm X 1500mm C.P.T.Wood frame work along with 6mm thk marine Ply for arms on either side.The sofa shall have 225mm height vertical type spring shall be fixed with thick nylon thread for the seat along with 100mm thk MM foam for seat, 75mm thk MM foam for back, 50mm thk MM foam for back, 50mm thk MM foam for handles with covering mix pieces of foam should be spread over the individual seat to have comfort along with approved make upholstery shall be used in wrinkle type design as a finishing material etc. complete as per detail drawing and instructions of the Architect / Engineer. (Basic Cost of Upholstery Rs.400/- Per Meter) CENTER TABLE (900mm X 450mm X 375mm) Providing center table in oval shape made out of 25mm dia Brush finish Stainless Steel frame work with 38mm X 38mm P.T.Wood frame work with Stainless Steel Stud with fixing of glass top & shelf.All exposed surfaces shall be finish with 3 coats MELAMINE polish including 12mm thk PLAIN glass for TOP & 10mm thk FROSTED glass fixed with Brush Finish Stainless Steel Studs etc. complete as per detail drawing and instructions of Architect Engineer. First Floor LOW HEIGHT CUPBOARD : Providing & Erecting low height storage 450mm to 600 mm in depth. The sides and shutters including shelves shall be made out of 50mm X 25mm P.T.Wood frame covered 6mm thick marine ply. The back shall have 12mm thick marine ply.The shutter shall be finish with approved color 1.5mm thick laminate.(Vertical Storage Laminate Finish), but the top, sides, shutters, shelves shall be made out of 19mm thk marine with necessary 50mm X 50mm P.T.Wood frame work with laminate veneer finish etc. complete.All exposed surfaces shall have approved color/ malamine finish, 1.5mm thk laminate and matching color ZINC OXIDE polish for internal surfaces etc. complete as per instructions of Architect/Engineer.(Note :- The furniture may be tailor made or customised as per the space available and should be executed as per instructions of Engineer In Charge) WARDROBE : Providing and fixing in position 600mm deep Wardrobe units 1.7x2.1x0.6) along the partitions/wall as indicated in drawings. Storage unit shall be made out of 19mm thick plywood for sides, and bottom. Shutters shall be made out of 19mm thick plywood finished with Laminate per profile externally and 0.8mm thick Laminate from inside. All shutter to be provided with cup hinges of approved make as drawing. Inside top & bottom ledges, sides and intermediate dividers shelves and internal exposed sides shall be finished with 0.8 mm thick Laminate & 1mm thick Laminate for all external top and sides. Rate quoted for the item shall include for cost of 19 mm thick plywood shelves including wooden beading, hardwares such as ball catches, locks, handles etc. Item to be completed in all respects as per drawings, specifications & instructions from Consultant. First Floor TV Unit - Providing and constructing TV unit size 2.4 m x 0.30m made in 18mm thick plywood with both side laminate finish table top, table edge, support, wire management, storages and all other accessories etc as per detailed drawings given by architects etc. complete. First Floor Providing and fixing in possition luggage rack size 1.70 x 0.6 x0.75 as per the approved drawings made in waterproof,antetermite treatment plywood of thickness 18mm with both side laminate finish as per the approved colour and design by Architect/Engineer incharge including fixing necessary accessaries polishing etc.complete. First Floor STUDY TABLE: Providing and constructing study table of size as directed with chair, table top, table edge, support, wire management, storages and all other accessories etc as per detailed drawings given by architects etc. complete. Laminate / veeneer finish painting/ malamine finish etc complete. (Note :- The furniture may be tailor made or customised as per the space available and should be executed as per the instructions of Engineer In Charge) ATTENDENT TABLE WITH SIDE TABLE Table Size: - 1650mm X 600mm X 750mm Side Table Size: - 900mm X 375mm X 750mm Providing & Fixing reception table with side table made out of 19mm thk marine frame work for top, sides, front apron, drawer box, shelves, key board along with 12mm thk marine ply for drawer side, step design for apron & 6mm thick marine ply for drawer bottom, back sides & curve shape etc. complete.The reception table & side table shall have approved color 18mm thk GRANITE slab for top with necessary edge MOULDING including 12mm thk PLAIN glass with ACID effect etc. complete. (Basic Cost Of Granite Rs.1830/- Per SMT)All exposed surfaces shall have approved color 1.5mm thk laminate along with METALLIC sheet for round shape & 2mm thk M.S. perforated powder coated sheet for apron fixed with Patch Fitting and inside shall have laminate matching color ZINC OXIDE polish including approved make Hardware such as Twin Telescopic Sliding Channels, Wire Manager, Approved Handles, Box Type Hinges,12mm thk marine ply wood 600mm X 450mm X 225mm height slope type Foot Rest finish with Rubber Mat finish, Powder coated CPU Trolley etc. complete as per detail drawing & instructions of the Architect / Engineer. First Floor Office table (1200X750x750mm) Top work surface shall be 12mm thick toughen glass with back painted design on to underside and crystal edge polished finished. The construction shall be knock down .Construction- The understructure shall have all pannels made from 36mm thick prelaminated board (Antitermide and Waterproof )with 2mm thick PVC edge beading ,understructure also consist of storage for CPU ,projector and paper .Storage- Provision for glass adjustment for glass alligning .The wire management shall have legend electricals use for wire on to center support beam panel and CPU storage area for socket connections , RJ11,RJ45 etc. colour and design approved by Engineering incharge complete. First Floor Providing and placing in position Side Table at inside cottage made with pitch wood polished with melamine polish of approved shade with 10mm thk. clear glass top of size 600 X 600 X 330 )as per Architects drawing and Make approved as Directed by Engineerin- charge etc,complete. First Floor Providing and fixing Consilled Door closer of Godrej make in possition including all necessry acessaries as per design approved by Architecr/ engineer in-charge etc. complete. First Floor STAINLESS STELL DUSTBINS (BRUSH STEEL) Providing & supplying stainless steel dust bins of 225mm diameter x 22 guge perforated sheet with plain border of 50mm on top & bottom. The bottom surafce shall be flat with round borders. The height of dustbins is 450mm. First Floor Providing and supplying Bathroom & Toilet Assessories like 17 liter Buckets, 2 liter Mug,dust bin , bathroom broom, etc. in bathrooms as per Architects drawing and approved Make as Directed by Engineer-incharge etc,complete. First Floor Providing and supplying good quality cotton Turkish type (Face Towel) napkins. Of size 405 mm x405 mm of approved colour and quality as directed by engineer in charge et. Complete.Specification as Directed by Engineer-in-charge etc,complete. PS good quality cotton Turkish type (Face Towel) napkins First Floor Providing and fixing in position electronic security chest/Locker having finger impression or digital number locking arrangement of medium size capacity .including all necessary equipment, connections and arrangement etc complete of make Godrej or equivalent as per instruction of engineer in -charge.Specification as Directed by Engineer-in-charge etc,complete. DRESSING TABLE WITH SEATTY TABLE: Providing and fixing Dressing table of size Depth - 450.0 mm Width - 450.0 mm Height - 1710.0 mm as directed with seatty including table top, table edge, support, storages and all other accessories etc as per detailed drawings given by architects etc. complete. Laminate / veeneer finish painting/ malamine finish etc complete. (Note :- The furniture may be tailor made or customised as per the space available and should be executed as per the instructions of Engineer In Charge) First Floor Dining Table With Chairs - 1.200 m x 1.200 m dining table with four nos. Of sofa chairs Leather Finish Do as above item ( Sofa - leathre finish), but sofa chairs shall have 500mm wide with both side handles etc.complete as per instruction of the Architect/Engineer. Providing and fixing in position First-aid box with first aid chart printed on the box with all first aid medicines such as sterilised dressings, antiseptic solutions, oinment for burn, crocin, first aid bookletas per Architects drawing and approved Make as Directed by Engineer-incharge etc,complete. Supplying and installing Office Signages of Size 4 x 6 Glass/SS with Vinyl as per Rooms cabin (Fire escape and Route prolite signages)as per Architects drawing and approved as Directed by Engineer-in-charge etc,complete. Providing and installing quartz type wall clocks as per color combination of interior with duracell battries of make Ajanta/ equivalent make base price not less than 1000.00 .including necessary hanging arrangement on wall etc. completeas per instruction of Engineer- in Charge.Specification as Directed by Engineer-in-charge etc,complete. First Floor Reception chair - High back chair in fabric. Double ply back with 3D bend and high density foam on back with mould seat Fabric upholstery on seat and back Back tilt mechanism Gas lift height adjustment Fixed PP arms Five prong fiber base with nylon castors for all floorings. Visitor Chair - Medium back chair in fabric. Double ply back with 3D bend and high density foam on back with mould seat Fabric upholstery on seat and back Back tilt maechanism Gas lift height adjustment Fixed PP arms Five prong fiber base with nylon castors for all floorings. Providing & Fixing of FREE STANDING King size Bed made in ply and mica of choice size is 2000 x 1800 x 400 Mm. Height Including 100 MM. Thick Matters, with Bed Back with Cusion and with bed sheets Design given by Engineer Incharge, With including side table size is - 450 x 400 D x 500 high. both side, As per furniture Layoutas per design and drawing and instructions of Engineer in charge.. Providing & Fixing of FREE STANDING Single bed made up of 18 mm ply and mica of choice Bed size is 2000 x 900 x 400 Mt. Height Including 100 MM. Thick Matters, with Bed Back with Cusion Design given by Engineer Incharge, With including side table size is - 450 x 400 D x 500 high. Single Side only , As per furniture Layout.as per design and drawing and instructions of Engineer in charge. First Floor Providing & Fixing of FREE STANDING Bed side tables made in 18 ply and mica of choice size is 450 x 450 x 400 Mm. Height with one drawer. As per furniture Layout.as per design and drawing and instructions of Engineer in charge. First Floor Providing and fixing Banquet hall Chair with Isosceles without handle- Size H:860mm, D- 580mm, W-540mm. Back and sit moulded cushion, back outer PPCP, Crape Tapestry, frame oval tube -13 x 13 mm -16g with power coated the over all dimension +/- 10mm Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. Transporation of all types of material upto 2 km Supplying hard murum/ kankar at the road site, including conveying and stacking complete. Spreading hard murum/ soft murrum/ gravel or kankar for side width complete Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading I (Using Screening Type B (11.2 mm) Aggregate) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate) Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) Painting Line, Dashes, Arrows etc on Roads in two coats on new work with ready mixed road marking paint confirming to I.S. 164 on Bituminous surface including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control (Over/Upto cm wide) (MORTH-803) - - SurfaceOver 10cm Wide On New Surface Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface be level, uniform, and free from streaks and holes complete as per direction of Engineerin- charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). Stamp Concrete of 100mm Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1:8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete. (prior approval of superinteding Engineer will be necessary ) Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand) Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a) Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms. ( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b) Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.14, item no 2) Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7 x 8(plants list) 1(a) serial no 15. Providing on site required variety of Hedges Well Developed, Healthy Foliage / Half Bloom Stage , Free from Pest and Diseases. apart c/c.Name:-Bougavillae Thema ;Bag Size 8 x 10 (plants list) 7(b) serial no 10. Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5) Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.29) Maintainance of Newly Developed Shrubs Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31) Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 800/cum = 522.40/-.(As per P&G DSR 2022- 23 Items of garden work,Sr No.45a) Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 19.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b) Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bahva (Amaltash);Bag Size 18 x18, ht 8- 10(plants list sr no1,item no 5C) Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:- Bakul;Bag Size 18 x18, ht 8- 10(plants list sr no2,item no 5C) Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bottle brush;Bag Size 18 x18, ht 8- 10(plants list sr no3,item no 5C) Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Gulmohar;Bag Size 18 x18, ht 8- 10(plants list sr no4,item 5C) Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kadamb;Bag Size 18 x18, ht 8- 10(plants list sr no5,item 5C) Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kanchan;Bag Size 18 x18, ht 8- 10(plants list sr no6,item 5C) Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Largesstroemea ;Bag Size 18 x18, ht 8- 10(plants list sr no7,item no 5C) Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Arjuna ;Bag Size 18 x18, ht 8- 10(plants list sr no3,item no 6C) Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Deshi Badam ;Bag Size 18 x18, ht 8- 10(plants list sr no4,item no 6C) Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Drooping Ashok ;Bag Size 18 x18, ht 8- 10(plants list sr no5,item no 6C) Providing on site Palms Specification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged. .. Apart c/c.Name:-Areca Palm ;Bag Size 18 x18, ht 8- 10(plants list sr no1,item no 11d) Providing on site Palms Specification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged. .. Apart c/c.Name:-Fox tail palm;Bag Size 18 x18, ht 8- 10(plants list sr no3,item no 11d) Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.12) Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.22) Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.(1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.27) Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.35) Planting Bamboo trees :- Digging pit with size 0.3m x 0.3mx 0.3m, removing conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil farm yard manure upto a height of 0.3m. In proportion. Mixing soil and manure thoroughly well, levelling , watering on previous night. Planting healthy bamboo trees saplings as per specification. Maintaining till well established by watering, stirring, of soil and manure, replacing casualties and transportation of plants to site etc. complete. Spiral Slide:- Providing and fabricating and erecting spiral slide with ISI mark G.I. Pipe assembly constitutes of the following. The sliding chute shall be made up of fiber reinforced plastic (FRP) type moulded one and shall be painted with attractive colours and shade, minimum joints shall be provided FRP spiral slide. The design of spiral is such that the children would not fall down while sliding in rotation towards down slide. The FRP slide shall be of 6 mm thick and should be finished both side with specialty designed horizontal landing where the child is going to got hurt. Platform height 3.0mtr. of aluminum chequred plate 3 mm thick with railing shall made up of FRP with safe railing having 20 NB GI pipe for grip, with a height of 500 mm recommended in the international safety standards. Central support pipe shall be made up of NB G.I ISI mark pipe with suitable arrangement. (length 4.0 m) Ladder, Railing and steps made up of 20 mm NB G.I. pipe with steps for ladder 12 Nos. length 0.4 m) Platform support pipe shall be made of 40 mm NB G.I. pipe 2nos of (3.5 m per no) G.I. pipe with proper foundation arrangement. The sate play area shall be a minimum of 3.5mtrs x 2.8mtrs. the painting shall be of required quality and support pipe are embedded in C.C. 2:4) mix of size 0.45 x 0.45 x 0.50 m and one coat of anticorrosive paint over it two coats of oil painting of approved quality and shade etc. complete as per design and drawing. All pipes are G.I. ISI ‘B’ class. Wave Slide ( FRP ( Fiber Reinforced Plastic) Roto Molding ( LLDPE/HDPE)Rec. Age 4-12 yearThe area :- 4.8 m x 0.5 mSafe play area :- 5.8 m x 1.5 mHeight 1.5 m This item consists of ISI marked structure. The attractive wave slide chute is made up of 4 mm thick fiber reinforced plastic materials. The structure comprises of 20 NB 25 NB powder coated GI pipe. The center support is made in 80 NB powder coated GI pipe.:The ladder cum railing is made 20 NB 25 NB GI pipes.The platform is made up 14 SWG GI sheet with anti skid for firm foot grip. There are triangular steps 16 SWG sheet. The chute has its end such as it causes safe landing of the child.All pipes are class pipes.All Structure Are of Powder CoatingAll Work done as per general Raw Material Sheet Added Below. Animal Merry Go Round - 4 Seater:- Rec.Age :- 3-12 yrs. The area :- 1.5 m dia Safe play area :- 2.5 m dia The mainframe of the animal merry go round is made up of 25 NB & 40 NB GI pipes. The GI pipes are powder coated. The stand is made in 80 NB GI pipes. All pipes are ‘A’ class pipes. The whole structure is mounted heavy-duty bearing shaft permanently lubricated with water sealant.The animal seats made out of molded plastic in rotational molding process (LLDP/HDPE) It accommodates 4 children at a time. Structure are of Powder Coating Work Done As Per General Raw Material Sheet Added Below. Multi Seater See-Saw:- Rec.Age :- 3-10 yrs. The area :- 3m x 0.5 m Safe play area :- 4 m x 1.5 m The MS See-Saw comprises four FRP FIBER REINFORCED PLASTIC/ROTO MOLDING (LLDPE/HDPE) Seats The lever is consisted of 20 NB and 80 NB powder coated GI pipes. The bearing used in this item is heavy duty nylon bush type. The stand for see-saw is made using 50 NB GI pipe All pipes are ‘A’ class pipes All Structure Are of Powder Coating All Work Done as per General Raw Material Sheet added Below. SATELLITE SCRAMBLER :-Rec.Age :- 4-12yrs.The area :- 2.4 M X 2.4 MSafe play area :- 3.4 m x 3.4 mHeight :- 3.4 M This item comprises top globular frame, ladder frame and support columm and steps. The pipes used in this item are 25 NB and 40 NB GI pipes.The top globe is fabricated from 25 NB GI pipes supported on a 40 NB vertical GI pipes. All pipes are ‘A’ class pipes.The structure is powder coated to avoid rusting and for esthetic look. The steps of the ladders are made from 15 NB GI pipes. The chain ladder is 7 mmThick for climbing the scramblerAll Structure Are of Powder CoatingAll Work Done as per General Raw Material Sheet added Below DOUBLE BAR :- Rec.Age :- 6-14 yrs. The area :- 1.9 M X 1.5 M Safe play area :- 2.9 m x 2.5 m The double bar being from exercise range provides a structure for physical exercise to the children the complete structure is made out using 40 NB powder coated GI pipes. The spacer pipes used are of 25 NB GI pipes All pipes are ‘A’ class pipes. All Structure Are of Powder Coating All Work Done as per General Raw Material Sheet added Below Simple Side (Galvanized iron Chute) :- Providing fabricating and erecting Simplex Side composed of 40 mm dia G.I. ISI mark 2 Nos. (3.00 m length per no) for supporting plant form, 20 mm dia G.I. Pipe for ladder slant 2 Nos. (3 m length per no) steps 11 nos. (0.40 m per no Railing 2 nos. (2.70 m per no) bracing 4 Nos. (0.20 m per no) and vertical 20 mm NB G.I. Pipe dia G.I. Pipe for hand rest at platform level 4Nos (0.45 m per No) 4 Nos. horizontal (0.50 m per no)and for side chute slant 2 Nos.(4.30 m per no) and for middle vertical support of side chute 2 nos. (1.30 m per no) and the end of chute vertical supports 4nos (0.9 m per nos) also M.S. angle 40 x40 mm x 5 mm as stiffeners below chute and along edges length wise (Total length 10.4mtr.) Railing and support pipe embedded in cement Concrete block (1:2:4 mix) of size 0.45 x0.45 x 0.45mtr and 18 Gauge Galvanize iron sheet for slide chute (4.30 m x 0.45 mtr.) and Aluminum chequred sheet 3 mm thick fixed on ISA 40 x 40 x 5 mm thick for platform size (0.50 m x 0.45 m) and one coat of anticorrosive paint and oer it two coat of oil painting of approved quality and shade etc. complete. As per detail design and drawing. All pipes are G.I. ‘B’ class ISI Mark. Rain – Bow – Ladder :- Providing fabricating and creating Rain – Bow – Ladder composed of two semicircular 40 mm NB GI ISI mark pipe (length of one pipe 6.28 m) embedded in cement concrete block ()1:2:4 mix) of size 0.45 x 0.45 x 0.45 m and 20 mm NB GI ISI round pipe 19 nos. (0.50 m length per no) for steps at equal spacing and one coat of anticorrosive paint and over it two coat of oil painting of approved quality and shade etc. complete as per detail design and drawing. All pipes are G.I. ‘B’ class ISI mark. Animal shape Dust Bin (FRP) :- Providing and fixing Penguin / Rabbit shape dust bin of size 2 feet diameter 3.5 feet height made out of animal shape Fiber Reinforcement Plastic structure of 5 mm thick in two colours well finished and smoothened with a door for opening on back side as per drawing and painting in attractive colour combination in synthetic enamels paint. Tube Slide :- Providing fabricating & erecting Tube Slide of platform height 1.5 m composed of 40 mm NB GI ISI mark 2 nos. (2.1 m length per no) for platform 20 mm NB GI ISI mark pipe of total length 23mtr. includes for Ladder slant 2 nos. (2.25 m Length per no) Steps 7 nos. (0.40 m per nos) Railing 2 nos. (2.0 m length per no) Bracing’s 4 nos. (0.2mtr length per no) and for platform 4 nos. (0.45 m length per no) 4 nos. (0.5mtr length per no) and for support 6nos (1.3 m length per no) and sliding chute in tubular shape shall be made up of fiber glass reinforced plastic ( FRP) 5 mm thick molded both side finish shall be with attractive colour a shade with Translucent dia 0.75 m and Translucent length 3.8 m with aluminum chequered plate 3 mm thick of size (0.5 x .04 m) all railing and support pipes are embedded in C.C. blocks M 15 (1:2:4) grade of size 0.30 x 0.30 x 0.50 m and one coat of anticorrosive paint and over it two coat of oil painting of approved quality and shade etc. complete as per detail design and drawing. All pipes are G.I. ‘B’ class ISI mark. Spring Duck Rider :- Made in 40 x 40 x5mm thick angle base with heavy duty spring of 2 Nos. with FRP animal duck of 3mm thickness etc. complete Two seat swing :- providing and fabricating and erecting Two Seat swing composed of to Horizontal ISI mark 50 mm NB G.I. Pipe of 3.0 m in length, vertical inclined G.I. Round Pipe 40 mm NB ISI mark 4nos (2.90 mtr length per No) for leg support and bracing pipe 40 mm NB G.I. Pipe 2 nos. (0.40 m per no) and inclined pipe shall be fixed firmly to top horizontal pipe, leg pipe shall be embedded with hold fast in C.C. bloc (1:2:4 mix) of size 0.45 x 0.45 x 0.45 m and two heavy duty ball bearing assembly for swinging with G.I. chain 8 mm, 4 nos. (2.30 m length per no.) Embedded with hold fast in C.C. bloc (1:2:4 mix) of size 0.45 x 0.45 x 0.45 0.45m and two heavy duty ball bearing assembly for swinging with G.I. chain 8 mm, 4 nos. (2.30m length per no.) and Aluminum chequred sheet 3 mm thick size 0.45 x 0.30mtr per sheet fixed on 15 mm NB G.I. ISI Pipe frame and one coat of anticorrosive paint and over it two coat of oil painting of approved quality and shade etc. complete as per design and drawing. Ornamental Cast iron chair 3 seater weight 100kg. Back rest with casting panel and sitting seat with cast iron Providing,Fixing of Art work made in Polyster Resin Gel Coat Chemical, casting & Molding with minimum 5mm thickness, along MS reinforcement with complete finished with required Primer & Dico colour as per the aesthetic of approved desgin & sizes 2-0 x 3-0 Ht Providing,Fixing of Art work made in Polyster Resin Gel Coat Chemical, casting & Molding with minimum 5mm thickness, along MS reinforcement with complete finished with required Primer & Dico colour as per the aesthetic of approved desgin & sizes 2-6 x 5-0 Ht Providing,Fixing of Art work made in Polyster Resin Gel Coat Chemical, casting & Molding with minimum 5mm thickness, along MS reinforcement with complete finished with required Primer & Dico colour as per the aesthetic of approved desgin & sizes. FRP Mural Providing & Fixing of Customize Acrylic Art Works for Words along with MS Stand of required sizes on plate , Back lite & Acrylic Name as per design & Specification Supplying and installation of following gymnasium equipments including all its fitings such as a) Tubular structure of 100x50x12 gauge thick in bending frame ,b) Bars & handles with all runner bars of 25mm dia and chrome plated,c)pulleys made of nylon and fitted with bearings,d) cushion made of 122mm commercial ply & 40mm thick PE Foam covered with rexine . Total equipments is shot blasted for pretreatment and powder coatigs is 90-100 micron.The equipments are instaaled with transportation and warrenty period as decided by enginner incharge.All equipments should be of international standards & of iported and of premium quality.4 HP AC Motor Treadmill Upight Bike Spin Bike 174 Elliptical Cross Trainer 175 Adjustable ABS Bench 176 Multy Purpose Bench 177 Hyper Extension 178 Multi Adjustable Bench 179 Plate Rack 180 Weight Plates 170.00kgs 181 Dumbbell Rack 182 Dumbbells 170.00kgs 183 4 station Multi Gym 184 Flat Bench 185 Flat Bench Press 186 Incline Bench Pass 187 Decline Bench press 188 Lat Pulldown 189 Bicep Curl Machine 190 Leg Extension 191 Chest Press 192 Seated Leg Curl 193 Pec Fly Rear Delt 194 Assisted Dip Chin 195 Leg Press Cum Hack Squat 196 T Bar 197 Cable Crossover 198 Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. 199 Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (HeatReflective Paint). ( Part-B ) 1 Royalty Charges on Mining materials used in construction. Sand 2 Royalty Charges on Mining materials used in construction. Murum & Soling Metal 3 Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Sieve Analysis Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local district/ regional laboratory etc. complete. ii) Liqiud limit & plastic limit Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local district/ regional laboratory etc. complete. ii) Compaction Test( proctor Density ) Carrying out test of concrete casted at site in the form of cubes of 150x150x150mm size casted during conctering in the laboratory including conveying the cubes/material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Compessive strength Carrying out Mix design with all Tests on Concrete Mix Design basic materials of concrete of various grade from the material collected at site in the laboratory including conveying all required material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. Carrying out Basic test of Cement Standard Consistency,Fineness, Specific gravity, setting time (initial & Final)Compressive Strength,soudness in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Crushing value, ii) Impact value, iii) Specific gravity, iv) Water absorption Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. v) Sieve lanalysis Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vii) Abrasion Value Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vi) Flakiness Index & Elongation Index. Fineness Modulus (sieve Analysi) Silt & Clay Content Chloride & Sulphate Content Silt Factor Testing of Steel Upto 16 mm (Set of 3 Bars) Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) Carrying out various test of HYSD / TMT FE-500 Steel transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Weight / metre, ii) Ultimate tensile stess, iii) Yield stress, iv) Elongation Test, a) Above 16mm dia. Testing of Bricks for- Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks). Density Test,Compressive Strength , Water Absorption Testing of Wood for Density and Moisture Content Testing of Flush door for Knife Test, Adhesion Test, End Immersion Test. Testing of Aluminium Section , thickness, mass per running meter GSB Mix design Carrying out Standard test of water Absorption , Flexural test on Flooring Tiles Ceramic tiles/Vetrified tiles etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local district/ regional laboratory etc. complete.(i) Water Absorption (Set of 6 Tiles, Flextural test (Set of 6 tiles) Carrying out Standard test of specific gravity on Flooring Stones (Kota Stone/graite Stones Stones etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete Carrying out test of PH Value, Sulphate & Chloride Content on Water in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local district/ regional laboratory etc. complete.
Contract Date: Oct 01, 2025 Contract Value : 7.07 Crore
Government Departments No of Bidders 4
Maharashtra View Result →
11.
Science and Technology #4942642 AOC
Bids Are Invited For Magnetic Stirrer With Hot Plate - Number Of Stirring Positions: 1Calibration: Automatic Calibrationtype Of Drive Motor: Motorless Magnetic Coil Typedisplay Option / Output Read Out Option: Digitalmagnetic Stirrer Is: With A Hot Plate Or Some Other Means For Heating The Liquidcontroller Type: Electronically Controlled And Programmablespeed Control Accuracy Of Set Speed ( + / - ) ( Rpm ) : 0Maximum Stirring Capacity Per Position: 2000 Milliliter , Automatic Water Distillation Equipment Double Stage - Electrical Requirements 230 Volts 10 / 50 Hz Single Phasedistillation Water Capacity ( Ltr / Hr ) : 4 Ltr / Hrph Value 6.9-7.0Conductivity ( Μs / Cm ) <1.0Numbers Of Built In Quartz Heaters ( Nos ) : 2Distillation Units Type: Horizontaldistillate Temperature ( 0C ) : 66.05Biological Activity: Pyrogen Freebuilt In Quartz Heater Capacity ( Kw ) : 3.5Double Stage Glass ( Quartz ) Distillation Units: Yescooling Water Consumption ( Ltr / Hr ) :140 Ltr / Hrelectrical Requirements 230 Volts 10 / 50 Hz Single Phasedistillation Water Capacity ( Ltr / Hr ) : 4 Ltr / Hrph Value 6.9-7.0Conductivity ( Μs / Cm ) <1.0Numbers Of Built In Quartz Heaters ( Nos ) : 2Distillation Units Type: Horizontaldistillate Temperature ( 0C ) : 66.05Biological Activity: Pyrogen Freebuilt In Quartz Heater Capacity ( Kw ) : 3.5Double Stage Glass ( Quartz ) Distillation Units: Yescooling Water Consumption ( Ltr / Hr ) :140 Ltr / Hrelectrical Requirements 230 Volts 10 / 50 Hz Single Phasedistillation Water Capacity ( Ltr / Hr ) : 4 Ltr / Hrph Value 6.9-7.0Conductivity ( Μs / Cm ) <1.0Numbers Of Built In Quartz Heaters ( Nos ) : 2 , Electronic Balance - Type Of Electronic Weighing Machine: Electronic Precision Pan Balancerated Load / Capacity ( Kg ) : 220 Gmresolution ( Gms ) : 1 Mgclass Type Class-Idisplay: Lednumber Of Display: Singlespeed Of Measurement: 4 Secondnumber Of Scale Division: 1000Tare Provision: Manualpower Requirement Mains Operated Battery Operatedpower Supply: Single Phasedc Operating Voltage In Volts: 6 Voltbattery Backup: Yesbackup Time ( Hour ) : 10Battery Type: Non-Rechargeablebattery Rating: Aaa1.5Vtype Of Sensing Element: Load Cellnumber Of Load Cell / Emfc: 1Class Of Protection: Ip 65Type Of Electronic Weighing Machine: Electronic Precision Pan Balancerated Load / Capacity ( Kg ) : 220 Gmresolution ( Gms ) : 1 Mgclass Type Class-Idisplay: Lednumber Of Display: Singlespeed Of Measurement: 4 Secondnumber Of Scale Division: 1000Tare Provision: Manualpower Requirement Mains Operated Battery Operatedpower Supply: Single Phasedc Operating Voltage In Volts: 6 Voltbattery Backup: Yesbackup Time ( Hour ) : 10Battery Type: Non-Rechargeablebattery Rating: Aaa1.5Vtype Of Sensing Element: Load Cellnumber Of Load Cell / Emfc: 1Class Of Protection: Ip 65Type Of Electronic Weighing Machine: Electronic Precision Pan Balancerated Load / Capacity ( Kg ) : 220 Gmresolution ( Gms ) : 1 Mgclass Type Class-Idisplay: Lednumber Of Display: Singlespeed Of Measurement: 4 Secondnumber Of Scale Division: 1000Tare Provision: Manualpower Requirement Mains Operated Battery Operatedpower Supply: Single Phasedc Operating Voltage In Volts: 6 Voltbattery Backup: Yesbackup Time ( Hour ) : 10Battery Type: Non-Rechargeablebattery Rating: Aaa1.5Vtype Of Sensing Element: Load Cellnumber Of Load Cell / Emfc: 1Class Of Protection: Ip 65 , Jar Test Apparatus Flocculator - Unit Supplied: With Glass Partsconstruction: Ms Powder Coatedheating Capacity Of The Heater ( Watt ) : 500Units Of Test: 6Rotating Speed: 10Rpm To 150 Rpmpower: 230V , 50 Hzflask Capacities ( Ml ) : 1000Electronic Display For The Speed And Temperaturedetails Of Other Accessories To Be Supplied Along With The Unit: Glass Partsunit Supplied: With Glass Partsconstruction: Ms Powder Coatedheating Capacity Of The Heater ( Watt ) : 500Units Of Test: 6Rotating Speed: 10Rpm To 150 Rpmpower: 230V , 50 Hzflask Capacities ( Ml ) : 1000Electronic Display For The Speed And Temperaturedetails Of Other Accessories To Be Supplied Along With The Unit: Glass Partsunit Supplied: With Glass Partsconstruction: Ms Powder Coatedheating Capacity Of The Heater ( Watt ) : 500Units Of Test: 6Rotating Speed: 10Rpm To 150 Rpmpower: 230V , 50 Hzflask Capacities ( Ml ) : 1000Electronic Display For The Speed And Temperaturedetails Of Other Accessories To Be Supplied Along With The Unit: Glass Parts , Indotronix Micropipette Single Channel Fully Autoclavable 0.5-5Ml - Type Of Micropipette: Variable Volume Single Channelmaterial Of Piston: Stainless Steelautoclavable: Yes Digital Volume Indicator: Withother Details Conforming To Specification: With Calibration Certificatevolume Range Of Variable Volume Single Channel Pipette: 0.5Ml -5Ml, Volume Increment ( In Ul ) : 10Type Of Micropipette: Variable Volume Single Channelmaterial Of Piston: Stainless Steelautoclavable: Yes Digital Volume Indicator: Withother Details Conforming To Specification: With Calibration Certificatevolume Range Of Variable Volume Single Channel Pipette: 0.5Ml -5Ml, Volume Increment ( In Ul ) : 10Type Of Micropipette: Variable Volume Single Channelmaterial Of Piston: Stainless Steelautoclavable: Yes Digital Volume Indicator: Withother Details Conforming To Specification: With Calibration Certificatevolume Range Of Variable Volume Single Channel Pipette: 0.5Ml -5Ml, Volume Increment ( In Ul ) : 10 , Rotary Shaker - Performance Parametersapplication: Mixing And Development Of Cultures Chemicals, Solvents And Assays Etc In Pathology, Microbiology, Chemical And Bio Technologymounting: Bench Topcontroller: Microprocessortype Of Motor: Brushless Dcsteeples Frequency Speed Control: Yesspeed Range In Rpm: 50 To 400Universal Platform With Adjustable Rollers And Surface To Accommodate Rechargeable Clamps Ofassorted Sizes / Capacities For Holding Conical Flaks: Yesshaking Amplitude In Mm: 10Material Of Body Ms With Powder Coatingcompact Counter Balance Drive Mechanism To Ensure Stability: Yesplatform Size In Length X Width In ( Mm X Mm ) : 12 X 12Flask Sizes Which Can Be Accommodated In Plat Form In Ml: 500Display: Ledparameters Displayed Speed With Preset Facilitytimer Range In Minutes: 99Auto Restart After Power Resumption: Yesmaximum Volume In Liters: 2Motor Protection In Case Of Over Load: Yes ( Led Light Flash, Auto Stop ) Power Supply: 230 V Plus Minus 10% 50 Hzweight Of Rotary Shaker In Kg: 8Dimensions Of Rotary Shaker: 320 X 415 X 130 ( Mm ) , Prestaltic Pump - Flow Range – 0.1Ml / Hr To 1000Ml / Hr Accuracy – ±2% Digital Display Of Functions And Time Auto-Stop With Audible Alarmbattery Back-Up Stores Memory In Case Of Power Failure.Flow Range – 0.1Ml / Hr To 1000Ml / Hr Accuracy – ±2% Digital Display Of Functions And Time Auto-Stop With Audible Alarmbattery Back-Up Stores Memory In Case Of Power Failure.Flow Range – 0.1Ml / Hr To 1000Ml / Hr Accuracy – ±2% Digital Display Of Functions And Time Auto-Stop With Audible Alarmbattery Back-Up Stores Memory In Case Of Power Failure. , Dissolved Oxygen Meter - Measurement & Range: Dissolved Oxygen - 0 To 20.0 Mg / L. Display: 13 Mm ( 0.5 ) Lcd, 3 1 / 2 Digits. Accuracy: ± 0.4 Mg / L. ( After Calibration Within 23± 5 ? ) Resolution: 0.1 Mg / L Power Supply: 006P Dc 9V Battery ( Heavy Duty Type ) . , High Volume Air Sampler - Flow Rate 39 To 60 Cfm For Mfc; Typically 42 To 45 Cfmfor Vfc; Volumetric Flow Control Accuracy ±1% Deviation Over 24-Hr Period;Power Requirements 110 / 220 ± 10V, 100W; Precision Of Pressure Stabilization 0.05 Mpa; Flow / Pressure Recorder With Circular Charts, 4 ( 10 Cm ) Dia.; Range 10 To 65 Cfm , Ph Meter - 20 X 2 Line Back Lighted Lcd Display., Ph Meter Complies To Usp And Din Standards, Alphanumeric Splash Waterproof Polyester Keyboard With Soft Keys., Range 0° To 150° C. , Turbidity Meter - 0 - 10, 000 Ntu , ± 2% Of Reading Plus 0.01 Ntu ( 0 To 1000 Ntu ) ± 5% Of Reading ( 1000 To 4000 Ntu ) ± 10% Of Reading ( 4000 To 10, 000 Ntu ) , Response Time: Less Than 6 Seconds, Sample Size: 30Ml, Operating Temperature: 0° - 50°C0 - 10, 000 Ntu , ± 2% Of Reading Plus 0.01 Ntu ( 0 To 1000 Ntu ) ± 5% Of Reading ( 1000 To 4000 Ntu ) ± 10% Of Reading ( 4000 To 10, 000 Ntu ) , Response Time: Less Than 6 Seconds, Sample Size: 30Ml, Operating Temperature: 0° - 50°C , Nessler Tube - Borosilicate Glass, 3.3Mm Thick, And 100Ml Capacity , Water Testing Kit - Drinking Water Testing Kit, Hardness, Ph Range, Chloride, Fluoride, Nitrate Turbidity Test, Weight Of Master Kit: 3Kgs Approx , Glass Tes Tube - Made Of Borosilicate , Laboratory Hot Air Over - Digital Laboratory Over ( 18X18x18 ) , Hot Oven 450Mm Digital , Thermometer - Digital Display, Accuracy + / - 1C , Incubator - 250V Ac, 5 To 60C, , Test Tube - Made Of Borosilicate , Bod Bottle - 300Ml Bottle , Made Of Borosilicate , Chloroscope - Square Unbreakable Test Tube - 2 Nos, Glass Dropper With Rubber Test-1No, O-Toluidine Reagent-125Ml, Packed In Thermocol Box, To Check Chlorine In Drinking Water From 0.25Ppm To 2Ppm , Porcelain Dish - Made Of Borosilicate , Measuring Cylinder - Made Of Borosilicate , Beaker - Made Of Borosilicate , Filter Paper - Made Of Borosilicate , Funnel - Made Of Borosilicate , Conical Flask - Made Of Borosilicate , Burette - Made Of Borosilicate , Laboratory Flocculator - Stirring Equipment For 4 Or 6 Places That Accommodates Beakers Up To 1000 Ml Tall Or 2000 Ml Short Shape, Stirring Speeds From 15 To 200 Rpm, Adjustable Timer Up To 999 Minutes Or Continuous Operation, Two Vertical And Horizontal Adjustable Illumination Units Can Be Placed In The Unit , Ordinary Or Non-Recording Rain Gauge - Non Recording Rain Gauge Should Be Manufactured From Non-Corrosive Fiberglass Reinforced Plastic As Per Is: 5225: 1969. Must Consists Of Collector Assembled With Gunmetaling, Funnel, Locking Rings And Base. , Self-Recording Rain Gauge - Rain Gauge Shold Be As Per Is 5235: 1969 And Made From Reinforced Fiberglass Plastic. Container Is Assembled With Gunmetal Ring And Locking Arrangements. Siphoning System And Recording Arrangements Are Manufactured From Brass / Pvc. The High Torque Quartz Clock Of Min 25 Hours Revolution.Must Suppy 100-Charts, Pen, 15 Cc Ink , Open Evaporation Pan - The Pan Shuold Be Manufactured From Copper / G I Sheet As Per Is: 5973: 1998, Duly Tinned And Epoxy Pointed, And Tested For No Water Leakage. , Wind Vane - Manufactured As Per Is: 5799: 1970 , Anemometer Cup Counter - Manufactured As Per Is: 5912: 1970 , Stevenson Screen - Manufactured From Best Quality Indian Seasoned Wood And Accurately Assembled With Side Louvers As Per Is: 5948:1970 And Are Suitable For Housing Dry Bulb, Wet Bulb, Maximum And Minimum Temperature Thermometer. , Thermometers - A Set Of Thermometers Which Will Be Used For Measurement Of Maximum, Minimum Air Temperature And Relative Humidity , Double Ring Infiltrometer - Infiltrometer Rings Made From Min.14 Gauge Ms Sheet Rolled And Butt-Welded. Hammering End Reinforced With ½” Iron Strip And Other End Sharpened For Smooth Entry In To Soil.Complete With One Inner Ring 30-Cm Dia.; One Outer Ring 45 / 60-Cm Dia. Min. Height Of Rings 30-Cm; Must Supply Additionally: Driving Plate With Hammer; Float, Guide Rod, Pointer Gauge & Stop Watch. , Pigmy Cup Type Current Meter - It Should Be Suitable To Measure The Water Velocities Up To 1.0 M / Sec. It Has To Meet The Requirements Of Is: 3910 And Supplied Duly Calibrated From Govt. Research Institute. , Cup Type Current Meter - It Should Be Suitable To Measure The Water Velocities Up To 2.5 M / Sec. It Has To Meet The Requirements Of Is: 3910 And Supplied Duly Calibrated From Govt. Research Institute. Accessories Required: 10 Kg Fish Weight, 10 M Suspension Cable And Other Accessories. , Model Of Earth’S Crust - Showing The Layers Inside The Earth With 7 Detachable Parts Showing The Interior Of Earths. , Model Of Earthquake And Tsunami - Showing The Origin, Motion Produced And The Effect Of Earthquakes. Various Types Of Seismic Waves. , Radical 50 Sets Of Rock Samples - Radical 50 Set Of Rocks Collection Of Different Rocks Collected From Different Places, Supplied In Wooden Box. Radical Each Specimen Labeled With Name , Set Of Minerals - Different Set Of Minerals, Supplied In Wooden Box. Each Specimen Labeled With Name. , Topographical Maps - One Of India And One Of Bihar, Paper Size A1 , Structural Geological Maps - One Of India And One Of Bihar, Paper Size A1 , Engineering Geographical Maps - One Of India And One Of Bihar, Paper Size A1 Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 16.45 Lakh
Government Departments No of Bidders 6
12.
Educational and Research Institute #1737323 AOC
Purchase Of Equipments , Refrigerated Centrifuge With Accessories:Rotor Capacity Max (4 X 100 Ml), Maximum Speed Rpm/Rcf (G) (15000 Rpm / 22388 G (Rpm & Rcf Varies As Per Rotor), Motor Type (Brushless Dc) Display (Digital Display), Speed Setting (500 – 15000 Rpm), Time Setting (30 Secs To 999 Mins & Infinite Mode),Lid Lock Safety (Yes), Imbalance Detection (Yes), Adjustable Ramp & Brake (Yes (Selection From 1 To 9), Weight (55 Kg (Without Rotor), Rotors (Not Included) Multiple Rotor Options (Swing & Fixed Angle Rotor), Temp. Range (-10° C To 40° C) , Analytical Digital Balance: Capacity (220 G), Readability (0.0001 G (.1Mg), Repeatability (+/- 0.0001 G), Linearity (+/- 0.0002 G), Pan Size (90 Mm Dia), Response Time (3 Second), Display (Moon Light Lcd Display), Calibration (Auto Internal Calibration), Operating Temp. (+ 5°C To + 40°C), Weighing Units (Gm, Mg, Ct, Gn, Oz, Ozt,Dwt), Power Supply (230V, 50/60 Hz, +/- 15%) , Ph Meter:Range : (0 To 14 Ph/0-2000 Mv), Resolution : (0.01 Ph/1 Mv), Accuracy : (0.01 Ph/+ 1 Mv), Slope Control : (85 To 110%), Ph Electrode : (With Bnc Attachment),Calibration : (Auto 2 Point), Temperature : (Auto With Pt 100 Probe), Display : (Led /Lcddisplay), Power: (220 Volt + 10% A) , Hot Air Oven: Deluxe Model Hot Air Oven With Digital Temperature Controller & Air Circulation Fan Outer Body Made Of M.S. Sheet And Inner Chamber Made Of Stainless Steel, , Vortex Mixer: Power (60W),Mixing Motion (Orbital),Orbital Diameter (4Mm), Motor Type (Shaded Pole Motor),Motor Rating Input (58W), Motor Rating Output (10W), Speed Range (0~2500Rpm), Speed Display Scale - Run Type Touch Operation/Continuous,Dimension[W×H×D] (127×130×160Mm), Weight (3.5Kg), Permissible Ambient Temperature (5~40Oc), Permissible Relative Humidity (80%), Protection Class (Ip21) , Freezer: Robust Construction Corrosion Resistant, Pre-Coated Gi Cabinet, Tropicalized For High Ambient Conditions, Lockable Lid, Double Door Option Available In Higher Capacities, Eco-Friendly Refrigerant R-134A Gross Volume (100), Net Volume (198), Temperature (-18),Dimension (1010X520x835) , Tissue Culture Rack – (No.Of Racks 5, Gi Pipe & Ms Frame) : Made With Tubular G.L. Pipe Or Tubular Aluminum Pipe,Duly Powder Coated.Having Rack Size Of 125 Cms Length And 53 Cms Width, Supporting Channels For Keeping The Culture Trays Are Provided In Each Rack Height Between Each Rack Is 38 Cms. Each Rack Is Fitted With Two Fluo: Led Tube And U.V. Tube 3 Feet. No. Of Racks (4) Material Of Construction (G.L. Pipe & Ms Frame) No. Of Racks (5) Material Of Construction (G.L. Pipe & Ms Frame) , Research Microscope With 14Mp Camera Andimage Analyzing Software: Trinocular Research Compound Microscope C Shaped Sturdy Stand, Siedentopftrinocular Tube, 30° Inclined, 360° Rotatable, Ipd 48-75Mm, With Dioptric Adjustment On Left Ocular, Wide Field Eyepiece Wf 10X/22Mm Paired With Eye Guards, Quintuple Reverse Angle Nosepiece (Ball Bearing Type) Infinite High Contrast Plan Achromatic Objectives 4X, 10X, 40X (Spring Loaded) And 100X (Spring Loaded, Oil Immersion), Stage Rectangular 216 X 160Mm Double Plate With Mechanical Stage, Cross Travel 76 X 55Mm On Ball Bearing With Co-Axial Control, Spring, Clip Double Slide Holder, Sub-Stage Abbe Condenser Na 1.25 With Aspheric Lens, Iris Diaphragm And Special Day Light Blue Filter, Co-Axial Coarse And Fine Focusing Mechanism With Tension Control And Unique Auto Focus Lock, Koehler Illumination System 3.3W Led With Intensity Control, Universal Power Supply (100V-240V) Iso 9001, Ce Approved, Packed In Molded Styrofoam Box, With Operation Manual, Dust Cover And Cleaning Cloth 14Mp Camera And Image Analyzing Software Sensor Size 1/2Inch Cmos Monochrome, Live Image Resolution 5440*3648 (14Mp), Frame Rates 5440*3648@17Fps 4080*2160@40Fps, Any Size Roi, Pixel Size 2.4Um*2.4Um, Scanning Linescanning, Shutter Rolling Shutter, Exposure Time 0.069-3000Ms, Bits Raw8/Raw10(Optional), Sensitivity 1.0V/Lux-Sec(550Nm), Spectral Response 380Nm-650Nm(With Ir-Filter)S/N Ratio 44Db, Dynamic Range 71Db, Measuring Tool (Line,Circle,Square,Angle Etc.), Exposure Control Auto/Manul/Regional, Image Format Raw,Bmp,Jpg,Png, Image Control Framerate,Imagedefination, Snapmode, Imagelightness, Exposuretime, Rgb,Gamma,Contrast, Sharpness, Pc System Windows Xp(32Bit); Win7(32/64Bit) ; Win8(32/64Bit), Software Interface Twain,Directshow, Output Usb3.0, Power Supply Usb 5V, Operating Temperature 0-50C, Storage Temperature -20-60C, Operating Humidity 10%-90%Rh, Storage Humidity 10%-60%Rh, Camera Mount C/Cs , Water Bath: Bath (300 X 250X 175Mm) Control (Thermostatic),Power (1500 W) , Spectrophotometer:Visible Spectrophotometer Wavelength Range (340 – 960 Nm), Wavelength Accuracy (±5 Nm), Wavelength Readout (5 Nm), Wavelength Display (Dial), Spectral Band Width (10 Nm), Photometric Accuracy (± 0.005 Abs At 1.000Abs Photometric Resolution (0.1% T, 0.001 Abs), Photometric Readout (4 Digit Seven Segment Led), Grating (600 Lines/Mm), Source (Tungsten Halogen Lamp), Detector (Wide Range Silicon Photodiode), Sample Holder (Single Position 10 Mm Cuvette Holder), Min. Sample Volume (1 Ml In 4 Ml Cuvette), Measuring Mode (Auto A)% Trasmittance B) Absorbance C) Concentration Power (230V ± 10%, 50 Hz), Dimension (420(W) X 310 (D) X 125 (H) Mm, Weight (6.5 Kg (Approx), Accessories (Two Glass Cuvettes), Optional Accessories (Single Position 20/50 Mm Cuvette Holder (Factory Installed) , Incubator: Incubator (Bottom Heated)Outer Body Made Of Ms Powder Coated, Inner Chamber Made Of Stainless Steel, Temperature Range Ambient +50C – 600C With An Accuracy Of ±10C. Temperature Controlled By Digital /Thermostatic Temperature Controller, And Circulating Fan With 2½ -Inch Glass Wool Insulation And Provided With Inner Plexi Glass Door Inner Size (Mm) (300X300x300),No Of Trays(2),Inner Size (Mm) (355X355x355),No Of Trays(2), Inner Size (Mm) (455X455x455),No Of Trays(2), Inner Size (Mm) (455X455x605),No Of Trays(3), Inner Size (Mm) (605X605x605),No Of Trays(3) , Autoclave- Vertical : Vertical Autoclave - -35 Litr. (Double Wall), Description Autoclave) Capacity(35 Ltr (300 X 500), Outer & Inner Ss , Rotary Evaporator: Rotary Vacuum Evaporator With Vertical Condenser, Vacuum Pump And Circulating Chillerunit Base Made Of Thick M.S. Sheet Coated With A Layer Of Epoxy Based Polyester Paint, Providing A Scratch Less & Chemical Resistant Surface. Geared Drive Unit Offers A Smooth Speed Rotation Precisely Controlled With Analog Knobs. Double Walled Bath - Seamless Inner Vessel Ss 304 & Outer Al, Provided With High Grade Insulation To Eliminate Heat Loss.Digital Temperature Indicator Cum Controller, Temp Range 180 C Sturdy Jack Arrangement Fitted On Main Base To Provide Jerk Free Up And Down Movement Of Glass Assembly. Extended Clamp Which Holds The Geared Drive Unit Can Also Accommodate Condenser Clamp Hanger With The Help Of Extra S.S. Rod For Vertical And Cold Trap Condensers. Central Processing Unit Is Fitted At The Rear Of Water Bath. Main On/Off Is At The Taper Of The Base Unit. Borosilicate Glass Parts Set Comprising Of Condenser, Evaporating Flask Kjeldhal Shape 800Ml, Receiving Flask Cap. 1000 Ml With S-35 Cup, Vapor Path Tube B-24, Feed Tube With Teflon Extension, Gasket Seal, Standard Joint Clip B-24, Ball Joint Clip S-35 Are Standard Part Of Equipment.All Borosilicate Glass Parts Are Interchangeable. Double Stage Chemical Resistant Vacuum Pump Make: Superfit Max Flow (Ltr/Minute) (45) Max Vacuum (Inches Hg) (27) Motor (Hp)¼ No Lubricant Required. All Parts Made From Special Fradedaluminum Die Cast Material Noiseless Performance Pumps Having Chemical Resistive Parts (Pp, Teflon) Valves Made Of Ss 316 Material Extra Large Bearing For Trouble Free And Smooth Running , Cauchys Constant Using Liquid Prism -Spectrometer, Hollow Prism, Mercury Vapour Lamp Set : Spectrometer - 6 Inch Diameter Stainless Steel Scale & D Vernier, Least Count 1 Minute Hollow Prism-Equilateral- Made Of Cemented Plate Glass Mercury Vapour Lamp - Complete Set - 80Wwith Choke In Box & Wooden Stand With Slits , Di – Electric Constant Using Lecher Wire:Vhf Oscillator : 360 Mcs To 410 Mcslecher Wire : Fitted On 1.75 Meter Bench Detector :Bulbtypecondenser : Parallel Platewooden Scale: 1 Meter Long Operative On 230V ±10% At 50Hz A.C. Mains , Magnetic Stirrer With Hotplate: Capacity - 1 Litre, Speed Range- 200 - 1500 Rpm, Speed Stability- +/- 2 Rpm, Temperature Range- Ambient To 200Oc, Heating Rate - 12Oc/Min, Temperature Sensor - Pt 100, Temperature Control- Microprocessor Based Pid Control, Temperature Control Accuracy - +/- 1O C, Hot Plate Material - Stainless Steel, Three Stirring Bars Of Different Sizes, User Interface - 20 X 4 Alphanumeric Lcd And Button , Keyboard, Real Time Display Of Speed And Temperature , Frank Hertz Experiment Apparatus: Frank-Hertz Apparatus, Argon Filled Tetrode, Voltage Supplied To Frank- Hertz Tube. Vg1k: 1.3 - 5V, Vg2a (Rejecting Voltage): 1.3 - 15V, Vg2k Point- Measure Observation: 0 - 100V,Filament Voltage: 2.8 - 3.4V (Continuously Variable),Sawtooth Wave Parameters,Scanning Voltage: 0 -90V, Scanning Frequency: 115± 20Hz, Ambient Temperature: -10 ~ 40 °C, Operating Power: Ac 230V Â, 50Hz , Elementary Experiments Using Laser : Semiconductor Diode Laser And Setup For Measuring The Diameter Of The Wire , G.M. Counter:G M Counting System :2Line 16Character,Lcd Dotmatrix Display(For Counts, Elapsed Time And Hv), Counts Capacity 999999, Preset Time 9999Sec , Variable Hv(0-1500V ,2Ma), Store And Recall Facility For Data Count ,+12V@ 1A Mains Adapter, End Window Gm Detector ,Stand For Gm Detector -Vertical Type, Pvc, Radioactive Source Kit [One Gamma Source(Cs-137) And One Beta Source(Tl-204)], Aluminium Absorber Set For Gm Counter, Lead And Copper Absorber Set , Millikans Oil Drop Experiment Apparatus: Oil Drop Chamber Mounted On Top Of The Panel Havinga Pair Of Horizontal Parallel Plate Electrodes Separated By About 5 Mm Thick Ebonite Ring With A Hole And A Device To Illuminate The Space Between The Plate Electrodes. A Microscope With Ccd Camera, 16” Led Flat Panel Monitor, Timer, Atomizer , Thomson’S E/M Measurement:With Microcontroller Based Lcd For Voltage Measurement, With Pair Bar Magnet And Compass Box, Helmholtz Coils Of Radii - 14 Mm, No Of Turns - 160 On Each Coil, Accelerating Voltage - 0 - 250V, Deflection Plate Voltage - 50 - 250 V, Operating Voltage - 220V Ac, 50 Hz , Optical Fibre Characterization Apparatus - Rail Based: Optical Rail, Laser Diode With Driver, Pin Hole Detector, Precision Xyz Transition Stage, 10X Condensing Lens, Screwgauge Type Measurements, Whole Parts In Anodized Aluminium , Katers Reversible Pendulum: Comprising Of A Steel Rod Of 120Cm Long And 1.2 Cm Dia With Pointed Ends, Carring Two Adjustable Knife Edges Facing Each Other. Two Metal Weights (Made Of Iron C.P) Of Dimension 7.5 × 3.75Cm (Length × Diameter) And (3.5 × 3.75Cm) Respectively. With Wall Bracket. , Spectrometer: 6 Inch Diameter Stainless Steel Scale & D Vernier, Least Count 1 Minute , Set Up For Measuring The Dielectric Constant Of A Thin Sheet Using Parallel Plate Capacitor : Digital Capacitance Meter, Parallel Plate Capacitor, Dielectric Thin Sheet, Dielectric Liquid, Capacitance Meter-Input Voltage 210-240V Ac, 50Hz, Range 0-1000Pf, Resolution1pf, Mains Socket 3 Pin With Fused Protection, Dielectric Of Solids Arrangement Capacitor. Parallel Mounted Aluminium Discs, Sample Thickness- 1Mm To 25Mm, Dielectric Of Liquids Arrangement Capacitor- Concentric Aluminum Cylinders With, Cavity For Liquid Flow, Suitable For Non Corrosive Inorganic Liquids Only. Sample Quantity 75Ml , Experimental Setup For Constant Ofthermocouple & Temperature Of Inversion: Thermocouple - Iron-Copper On Wooden Support With Terminals, Thermo Emf Amplifier, B) Reference Thermometer, C) Electrical Kettle , Quartz Prism (Small):24 X 24 Mm , Diffraction Grating:Imported - 600 Lines/Mm , Digital Storage Oscilloscope:Bandwidth - 50 Mhz, Channels - 2+1, External Trigger – 1, Maximum Sample Rate - 1Gsa/S, Maximum Memory Depth - 200,000 Points, Waveform Update Rate - 100,000 Waveforms Per Second, Wave Gen - 20 Mhz, Integrated Digital Voltmeter – Standard, Frequency Counter – Standard, Built-In Training Signals – Standard, Waveform Math - Add, Subtract, Multiply, Divide, Fft, Low Pass Filter, Display - 7 Inch Tftlcd Wvga, Connectivity - Usb 2.0, Lan , Digital Water Quality Tester [Ph , Temp. , Tds , Mv(Orp) , Conductivity]: Microcontroller Based Ph, Temperature And Mv Meter (3 Point Calibration) 3.5 Digit Red Led Display. One Touch Calibration. Supplied With Combination Ph Electrode, Rtd Probe, Electrode Stand, Buffer Tablets(7, 4 & 9 Ph), Sample Bottles (3 Pieces) 16 X 2 Lines Backlit Alpha Numeric Lcd Display Showing Conductivity, Tds & Temperature Values Of The Sample. Features Include Auto Ranging, Selectable Referencetemperature, Data Storage Upto 1000 Samples Rs 232Computer Interface And Parallel Port For Connecting Printer. Supplied With Tds / Conductivity Cell, Stand For Cell, Rtd Probe, Rs-232 Cable & Operation Manual. Works On 220V ±10% Ac , Digital Turbidimeter: 16 X 2 Lines Backlit Lcd Display, Having Two Ranges Upto 1000 Jtu With Memory Storage Of 2 Standards To Avoid Frequent Use Of Standard Solution. Features Include Data Storage Upto 1000 Samples, Rs 232 Computer Interface And Parallel Port For Connecting Printer. Supplied With Sample Cuvettes, Rs-232 Cable, Rtd Probe, Operation Manual & Dust Cover. Works On 220V ±10% Ac , Depth Sampler: Water Samples –Field Collection,2 Litre Capacity. (To Collect Water Samples From Desired Depths. Acrylic Body, Rope And Pulley And M.S Galvanised Messenger) , Grab Sampler:(Stainless Steel With 15 Metre Rope – For Collecting Sediment Samples From The Bottom Of Water Bodies) Grab Sampler Fully S.S With 15 Mtr Rope , Horizontal Glass Double Distillation Unit- 5 Litre/Hr: All Glass Double Distillation Unit Borosilicate Boiler, Borosilicate Condenser And Quartz Heater, Horizontal Type(3.5Kw X 2, 4 Litre) , Portable Do Meter: Dissolved Oxygen Meter (Do) , Uv- Visible Spectrophotometer: Estimation Of Nutrients, Proteins, Bacterial Cell Culture,?Controller Based Vis. Spectrophotometer (340Nm-960Nm) , Rotary Shaker (With 18” X 18” All Purpose Table Top): Orbital Shaker Includes A Platform With Continuous Operation, Max. Load Capacity (With Platform) : 250Mlx16nos, Motor Type : Bldc Motor Motor Input Power : 16W Motor Output Power : 30W Speed Range : 0-80Rpm Speed Display : -Lcd Timer Display : -Lcd Time Settings Range : -0-9999 Minitue Voltage : 100-240V,50/60Hz , Trinocular Microscope, 40X-1500X Mag, Led Illumination With Semi-Plan Achro Objectives, 5.0Mp Cmos Camera And Kit (For Pathogen Detection): Trinocular Research Compound Microscope With 2 Mp Camera, And Image Analyzing Software. C Shaped Sturdy Stand Siedentopf Trinocular Tube, 30° Inclined, 360° Rotatable, Ipd 48-75Mm, With Dioptric Adjustment On Left Ocular Wide Field Eyepiece Wf 10X/20Mm Paired With Eye Guards Quintuple Reverse Angle Nosepiece (Ball Bearing Type) Infinite High Contrast Plan Achromatic Objectives 4X, 10X, 40X (Spring Loaded) And 100X (Spring Loaded, Oil Immersion) Stage Rectangular 216 X 160Mm Double Plate With Mechanical Stage Cross Travel 76 X 55Mm On Ball Bearing With Co-Axial Control, Spring Clip Double Slide Holder Sub-Stage Abbe Condenser Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Day Light Blue Filter Co-Axial Coarse And Fine Focusing Mechanism With Tension Control And Unique Auto Focus Lock Illumination System 3.3W Led With Intensity Control. Universal Power Supply (100V-240V) Iso 9001, Ce Approved Packed In Molded Styrofoam Box, With Operation Manual, Dust Cover And Cleaning Cloth 2Mp Camera And Image Analyzing Softwar , Rotary Microtome: Senior Precision Rotary Microtome Spencer Latest 820 .The Feed Indicator, Located In Front Of Microtome Is Operated By The Latest “Cam Drive System’ For Accurate Feed Setting From 1-50 Microns In Steps Of One Micron. It Is Graduated In Microns, Is Conveniently Located In The From For Instant References And Its Setting Is Controlled By A Knurled Knob At The Back Of The Microtome. The Interior Mechanism Rests On A Heavy Cast Iron Base And Is Coved With A Full Swing Protective Cover For Easier Cleaning And Lubrication. , Deep Freezer – Horizontal Chest Type (170 L, 550 X 30 X 680 Mm, - 20 Degree Celsius –With Digital Temp. Controller).: Deep Freezer With Suitable Voltage Stabilizer With Digital Controller. Robust Construction Corrosion Resistant Pre-Coated Gi Cabinet Tropicalized For High Ambient Conditions. Gross Volume: 200 Net Volume:118 Temperature:-18. Dimension: 1010X520x835. , Ordinary Compound Microscope: Monocular Compound Student Microscope With Detachable Mirror/Led Unit. Stand: Stable And Robust Modular Base Viewing Head Monocular Tube, 90° Inclines Back,Eyepieces: Two Huygenian Eyepiece Wf 10X/15X. Nosepiece: Quadruple Revolving Nosepiece Objectives: Achromatic 10X/0.25 40X(Sl)/0.6Detachable Mechanical Rectangular Stage Size 120 X 120Mm Cross Travel 75(X) X 25 (Y) Mm On Ball Bearing Condenser: Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Focusing Module: Separate Coarse & Fine Focusing Mechanism,Illumination System:Mirror. , Bacteriological Incubator (Bottom Heated) 35 X 35 X 35 Cm, 2 Shelves): Incubator (Bottom Heated)Outer Body Made Of Ms Powder Coated, Inner Chamber Made Of Stainless Steel , Temperature Range Ambient +50C – 600C With An Accuracy Of ±10C. Temperature Controlled By Digital /Thermostatic Temperature Controller, And Circulating Fan With 2 ½ -Inch Glass Wool Insulation And Provided With Inner Plexi Glass Door. Inner Size: 355X355x355 No. Of Trays: 2 , Inoculation Hood (75Cm X 50Cm X 75 Cm) : Inoculation Hood- Vertical (Laminar Flow Cabionet – Satin Finish – Ss, Table Top Model60 X 60 X 60 Cm Working Area, 70 X 76 X 198 Cm Working Area, Deep Pleat Hepa, Cleanliness Class 100 With Efficiency 99.9%, Particle Retention 0.3 Micron And Above, Static Inclines Pressure Manometer, Prefilter And Hepa Filter. , High Speed Homogeniser (1/12 Hp Ac/Dc Universal Motor, Chuck Coupling, Separate Auto Variac Speed Regulator Up To 5000 Rpm): High Speed Homogenizer, Motor Hp:1/12 Coupling: Chuck Speed: 5000 Rpm , Rectangular Water Bath (Thermostatic, Ring Type -35 X 35 X 12.5 Cm, 1500 Watts, 9 Holes): Double Wall Concentric Ring Water Bath, Bath: 9 Holes,Control: Thermostatic , 100-1000 Microlitre Micropipette Variable Volume With Calibration Certificate: 100-1000 Microlitre Micropipette Variable Volume With Calibration Certificate - Borosil , Digital Photoelectric Colorimeter With 8 Filters (1 Ml) [2 Nos]: Wavelength Range : 420-720 Nm, Minimum Volume : 1 Ml, Std Glass Filters: 8 Filters, Display: 3 Digit Digital Display Calibrated In Optical Density Only, Resolution: 0.01 In O.D. Or Abs, Detector : Sealed,High Sensitivity Silicon Photocell, Light Source: 6 V Led, Power: 230V Ac+/-10%,50Hz , Soxhletextraction Unit[1 No]: Heating Mandile Withrb-250Ml , Centrifuge : Supply: 220 - 240 Volts 50 Hz Single Phase, Rotor Capacity (Ml): 8X15 Ml; Type Of Head: Swing Out Head, No. Of Tubes: 8; Max. Speed (Rpm): 3500, Max. Rcf: 1600; Weight: 8.5 Kg; W X D X M: 310 X 310 X 295 , Hot Air Oven: Outer Body Made Of Ms Powder Coated, Inner Chamber Made Of Stainless Steel, Temperature Range Ambient +50C – 2500C With An Accuracy Of ±10C. Temperature Controlled By Digital /Thermostatic Temperature Controller And Circulating Fan With 2½-Inch Glass Wool Insulation And Provided With Inner Plexi Glass Door , Magnetic Stirrer: Magnetic Stirrer 2 Ltr Capacity With Hot Plate And Speed Indicator , Laboratory Water Purifier: 1) Direct Q 3 Water Purification System Should Quote, 2) Water Purification System Should Be Capable Of Producing 18.2, Megaohm Resistivitywith Pretreatment Cartridge, Reverse , Smosis And Mixed Bed Ion Exchange Resinsand Activated Carbon In A, Single Pack, With Feed Water Acceptance Of Upto, 2000Micro Siemens Conductivity, Fouling Index (Sdi) ≪ 12, Total Chlorine ≪ 1 Ppm. 3) All In One Pack Which Contains A Combination Of Technologies To Produce Ultrapure Water From Tap Water Directly. 4) It Should Have Only Cartridge In The System. If The System Comes With More Than Onecartrdige Then That Cartridge Should Quote Mandatorily 12 Numbers ( Including Ro)Along The Main Quote Is Mandatorily. 5) Detailed Indication Of All The, Components, Accessories & Consumables To Be Mentioned Separately In The Technical Bid, Otherwise It Will Be Rejected. 6) Kerala Customer Details Should Furnish, 7) Type 3 Water Flow Rate Should Be 3 Litre/Hour. 8) Kerala Customer Satisfaction Letter Should Enclosed Along With The Tender. 9) Minimum 10 Installation Of Quoted Model In Kerala Should Furnish. Ultra Pure Water Specifications, Resistivity : 18.2 Meg Ohm.Cm (@ 25 Degree C ) Conductivity : ≪ 0.055Us/Cm, Toc : ≪10 Ppb, Bacteria : ≪ 0.1 Cfu/Ml, Pyrogen : ≪0.001Eu/Ml, Rnase : ≪0.01 Ng /Ml, Flow Rate : 0.5 L /Min, Particulates ≫ 0.22U : ≪1 P/Ml , Bottle Top Dispenser: Bottle Top Dispenser 10-100Ml , Ph Meter [Digital]: Range : 0 To 14 Ph/0-2000 Mv, Resolution : 0.01 Ph/1 Mv, Accuracy : 0.01 Ph/+ 1 Mv, Slope Control : 85 To 110%, Ph Electrode : With Bnc Attachment, Calibration : Auto 2 Point, Temperature : Auto With Pt 100 Probe, Display : Led /Lcd Display, Power: 220 Volt + 10% A
Contract Date: Mar 29, 2023 Contract Value : 22.92 Lakh
Boards / Undertakings / PSU No of Bidders 20
TenderDetail
Loading tenders