3.
Housing Urban and Rular Development #10427022 Price Bid
Construction Of Sump Well Pump Room And Sitc Of Rotary Lobe Pump Sets Along With Related Eandm Equipments At Rahim Khan Road Nizamuddin East New Delhi Under Ser-1 Civil And Electrical Work-SH-I Pump Set WorkSupplying, installation, testing and commissioning of Positive displacement Rotary Lobe Pump for draining/dewatering of storm water/sewer water compatiblefor VFD (variable frequency drive) having minimum discharge 500 m3 /hr at 68Hz and 170 m3/hr at 25 Hz for 10 mtr. head and 5 mtr. suction Lift capacity complete withGeared Motorwith minimum power 45 kW/60 HP, 4 Pole suitable for operation on 415 Volt 50 Hzas per additional specification etc. as required. 2 Supplying, fabrication & installation of45KW VFD AUTO CONTROL PANEL made out of CRCA sheet steel of thickness 2mm for load bearing members, 1.6mm for non load bearing section with necessary stiffeners as required. 3 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 4 250 m.m dia 5 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required: 6 250 m.m dia 7 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 8 40 mm dia 9 80 mm dia 10 250 mm dia (wall thickness 6.3 mm) 11 450 mm dia (wall thickness 7.0 mm) 12 Fabrication, Supplying, Installation Testing & commissioning of automatic motorised Mechanical Coarse Bar Screen Suitable for channel dimension:i) Channel width: 1000mmii) Channel Depth: 3500 mmiii) Water Depth: 1500 mmiv) Bar Spacing: 20 mmv) Bar size : 12X6X50 mm vi) Angle: 75 Degreevii) MOC: SS304 Peak Flow/ Screen: 27MLDi/c Supplying, Installation, Testing & commissioning of 1No relay based control panel made out of 2mm thick CRCA sheet for 2Nos. Mechanical Coarse Bar Screen & 1No.Belt Conveyor etc. complete as required. - 13 Supplying, Installation, Testing & commissioning of Differential Level Sensorcomprises of Two Ultrasonic Level Sensors and One Differential Transmitter for Mechanical coarse bar screenetc. complete as required. 14 Supplying, Installation Testing & commissioning ofBelt Conveyor of size 600 mm width and2000mm Length i/c accessories for screen etc. complete as required. 15 Supplying, Installation Testing & commissioning of Gate Assy FG A101 Cast Iron Side Wall Embedded Oen Channel Gate (101) Size: 1000(W) X 1000 (H) mm Suitable for 1.75 m Seating water head (From invert Level) , Flush Bottom Closure Arrangement , Manually operated, Close Top Frame Gate etc. complete as required. 16 Supplying, Installation Testing & commissioning of Ultrasonic Level Transmitter with 4 ANSI PP Flange etc. complete as required. 17 Supplying, Installation Testing & commissioning of Local Control Stations for Pump Motors having following accessories i/c making connections etc. complete as required:a)DP MCB, 10kA, C-Curve for Control, 6A;: 1 No.b)Ampere meter, SIF-96, CI-1, Aux Supply 230V AC; 4-20mA I/P;1 No.c)Indicating Light-RED for ON;1 No.d)Indicating Light-AMBER for TRIP;1 No.e)Push Button with 1 NO contact - GREEN for VFD START;1 No.f)Push Button with 1 NC contact - RED for VFD STOP;1 No.g)Push Button with 1 NC contact - Mushroom head RED;1 No.h)Thermistor Relay 252 PMTG;1 No.i)Control Terminals, 2.5 sqmm; 6A;22 Nos. 18 SH-II Diesel Generator SetSupply, installation, testing and commissioning of Silent Type, CPCB IV + emission compliants Diesel Generating set having Prime Power Rating of 200 KVA, at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3 Phase system & for 0.85 Load Factor with all necessary equipments and accessories and consisting of followings :(a)Diesel EngineDiesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 degree C, 50 % RH & at 1000 meterMSL and conforming to BS 5514, BS 649, IS 10000(amended upto date), capable of taking 10 % overloading for 1 hourafter12hourofcontinuousoperation.Theenginewillbefittedcompletewithall accessories as per specifications .(b)Enginemountedinstrumentpanelfittedwithandhavingdigitaldisplayforthe following :-(i) Start stop switch with Key (ii) Water temperature indication (iii) lubrication oiltemperatureindication(iv)lubricationoilpressureindication(v) Batterycharging indication (vi) RPM indication (vii) Over speed indication (viii)Low lube oil trip indication(ix) Engine hour indication. 19 (c)AlternatorSynchronous alternator rated at 200 KVA, 415V, at 1500 RPM, 3 Phase, 50Hz, AC Supply with 0.8 lagging power factor at 40 Degree C, 50% Relative Humidity & at 1000m above MSL. The alternator shallbehavingSPDPenclosure,brushless,continuousduty,self-excitedandself-regulatedthrough AVR, confirming to IS: 4722 /BS : 2613suitable for tropical conditions and withF/H insulation.(d) Base Frame &foundation: Both the Engine & alternator shall be mounted on suitable baseframemadeofMSchannelwithnecessaryreinforcementwhichshallbeinstalledon suitablecementconcretefoundationandvibrationisolationarrangementasper recommendations of manufacturer.(e) Fuel Tank : Daily service fuel tank ofminimum 385 Ltr capacity fabricated out of 3mm thick MS sheet complete with all standard accessories and fuel piping between fuel tank & diesel engine with MS class C Pipe of suitable dia complete with valves, level indicators, and accessories as required as per specification.(f) Exhaust System : Dry exhaust manifold withsuitable exhaust residential gradesilencer . 20 (g) Starting system : 24V DC starting system comprising of starter motors, voltage regulator and arrangementforinitialexcitation,completewith suitableno. of batteries(25Plates,180 AmpsHour Capacitylead acid type) as required as per specification.(h) Acoustic Enclosure : Acoustic and weather proof enclosure with arrangement for fresh airintakeforcoolingoftheengineandalternator,extractiondischargeofhotairinto atmosphere as per specifications. 21 AMF Panel(i) Fabricating,Installation, Testing & Commissioningofautomaticmainsfailurecontrolincludingautobypasspanel,suitable for 200 KVAsilenttypeDGsetcompletewithrelays,timers,setofCTs,formeteringand protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH& Provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to Diesel Engine and elsewhere, if required, all complete and interlocking including the following :-(a) 3 nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release.(b)Auto / manual /test/off selector switch.(c) 2 nos. over voltage relay, 2 nos. reverse power relay and 2 nos. under voltage relay.(d)1 no. Auto mains failure relay(e) 3 sets of current transformer15P 10 accuracy for protection andclass 1, 15VA class-Ifor metering and. AMF Relay.(f) Energy analyzer unit to indicate current, voltage, frequency power factor and KWH.(g) Indicating lamps for load on mains and load on set.(h) Fuse for instruments.(i) Battery charger, complete with all accessoriesand Ammeter,voltmeter etc. 22 (j) Supply failure& restoration timer(k) Main supply failure monitor(l) Control unit with three impulse automatic engine start/stop and failure to start lock out.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator.(o)Aux. contactor 2NO+2NC(p) Audio/Video annunciation for :(i) High water temperature.(ii) Low lubricating oil pressure.(iii) Engine over speed(iv) Engine fails to start.(v) Full load/ Maximum load warning. 23 Main LT PanelSupplying, installation, testing & commissioning of LT panel of minimum front area 3.15 sq. mtr. and depth not less than 45 cm, made out ofCRCA Sheet Steel 2mm for section with necessary stiffeners as required. Free standing, self supported, floor mounting, single front, indoorinstallation, non draw out and compartmented. ISMC-100 fabricated channel frame with undrilled holes.Bottom with undrilled detachable 3mm gland plate as per order .Welding will be carried out with no external deposition of welded material in particular places and there will not be any gap between the welded materials.Siemens Grey RAL 7032CRCA Structures shall be pre-treated in seven tank chemical process, heated in baking oven.Minimum 60 micron of approved shade (RAL-7032).230V AC for Main LT Panel and Other Panels415+/- 5% , 50Hz+/-5%, 3 Phase 4 Wire 50KA – 1 Sec TPN Aluminum Electrolytic Grade ( E-91E) busbar shall be provided as per suitable sze, duly supported on SMC/DMC, busbar supports & insulated with color coded heat shrinkable sleeve. Power wiring will be through Vertical Bus -Bar and 1.1 KV grade PVC multistrand copper flexible cable . All control wiring will be done by 1.5 sq mm copper flexible PVC multi strand wire. CT wiring shall be carried out with 2.5 sq mm copper flexible PVC multistrand wire.1. All R,Y,B,N phases will be Red, Yellow , Blue & Black 2.All control wiring will be Grey colour. Earthing shall 24 be be with Green color wire.3.C.T. - Wiring through Red, Yellow, Blue, Black coloured wiring with shorting link type terminals.EPDM gasket provided at all joints, doors & covers to make panels dust & vermin proof (IP-52)Section-I(a) INCOMER :-1No. 4nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release. Ics=100%Icu i/c extended rotary handle and spreaders and all required accessaries Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch & back up HRC fuses/MCBs … complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set(b) 400 AOnload Change over SwitchIcs=100%Icu i/c extended rotary handle and spreaders and all required accessories- 1setIndicating lamp On, OFF, TRIP /R/Y/B/Ready to close complete 1set(c) OUT GOINGS:- 4Nos. 100A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etc complete as reqd. 25 Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch etc complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set3 Nos. 63A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etcwith indicating Lamps complete as reqd. 26 SH-III EI Work Supplying & Laying of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following size on cable tray as required. 27 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable (clamped with 40x3mm MS flat clamp) 28 3 X 50 sq mm (clamped with 25x3mm MS flat clamp) 29 Supplying, Laying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cableof 1.1 KV grade of following sizes on wall surface etc. as required. 30 4X25 Sq. mm. (clamped with 1mm thick saddle) 31 Supplying & Laying and fixing of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following sizedirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 32 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable 33 Supplying and Laying of XLPE insulated and PVC sheathed Copper conductor armoured Power Cable of 1.1 KV grade of following size on cable tray as required. 34 4x4 Sq.mm. 35 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 36 3½ X 240 sq. mm (62mm) 37 3 X 50 sq. mm (32mm) 38 4 X 25 sq. mm (28mm) 39 Supplying and drawing following size of PVC insulated copper conductor multicore cable of following size on cable tray as required. 40 10 core 1.5 sq.mm 41 24 core 0.5 sq.mm 42 4 core 0.5 sq.mm 43 2 core 1.5 sq.mm 44 6 core 0.5 sq.mm 45 3 core 0.75 sq.mm 46 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 47 100 mm width X 50 mm depth X 1.6 mm thickness 48 450 mm width X 50 mm depth X 2.0 mm thickness 49 EarthingEarthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 50 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 51 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithbrassnut,bolt,spring,washerexcavationandre-fillingetc.as required. 52 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 53 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithG.I.nut,bolt,spring,washerexcavationandre-fillingetc.as required. 54 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. asrequired. 55 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 56 Group C 57 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 58 3 x 4 sq. mm 59 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 60 25 mm 61 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 62 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 63 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 64 4 way (4 + 12), Double door 65 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 66 Single pole 67 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 68 63 amps 69 Supplying, Installation, testing & commissioning of weather proof LED Corrosion resistant battentype LED fitting of following wattagewith IP65 body made out of polycarbonate housing & opal diffuser with better thermal managementCCT-5700°KLumen Efficacy ≥110 Lm/W Power Factor≥ 0.95, CRI≥70, with constant current driver etc. complete as reqd. 70 36 Watt (4 feet ) 71 SITC of 450 mm heavy duty Exhaust Fan 1400 RPMsingle phase 240 Volt 50 Hz in the existing opening, complete with heavy duty louver/ shutter i/c making the hole to suit the size of the above fan, making good the damages, connection, testing, commissioning & earthing etc. as required 72 SITC of 600mmwall mounted fan having 3 nos. of blades, 1440RPM etc complete as reqd. 73 SH-IV AMCAMC for pump sets, Motor control panel and other accessories starting after satisfactory completion defect liability period from date of completion and commissioning of the pumping system.Annual Comprehensive maintenance for all 3 Nos. Pump sets, Motor, VFD Auto control panel, Mechanical Course Bar Screen, Differential Level sensor, Ultra Sonic Level Transmeter, Belt conveyor, Gate assembly including all accessories and consumables etc. all complete and as per site requirement as per Engineer-in-charge. 74 For 1st Year (Free Maintenance period) 75 For 2nd Year 76 For 3rd Year 77 Comprehensive maintenance of 200 KVA Silent type DG Set with AMF Panel. Annual Comprehensive maintenance of 200 KVA DG set and its accessories with AMF Panel i/c repairing, servicing, cleaning, checking and Descaling with replacment of following consumable parts i.e oil filter, fuel filter, air filters, coolant, lube oil, coolant filter, battery water, V Belts and batteries etc. complete and as per site requirement as per Engineer-in-charge. 78 For 1st Year (Free Maintenance period) 79 For 2nd Year 80 For 3rd Year 81 Civil WorkDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 82 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 83 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. 84 All kind of soil. 85 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 86 Providing and laying in position ready mixed or site batched design mix cement concrete for plai plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads: but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 87 Concrete of M10 grade with minimum cement content of 220 kg /cum 88 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 89 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 90 Suspended floors, roofs, landings, balconies and access platform 91 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 92 Edges of slabs and breaks in floors and wallsAbove 20 cm wide 93 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana / Ordinary Portland /Portland Slagcement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade withminimum cement content of 330 kg /cum 94 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 95 Thermo-Mechanically Treated bars of grade Fe-500D or more. 96 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 97 Cement mortar 1:4 (1 cement : 4 coarse sand) 98 12mm cement plaster of mix 1:4 (1cement:4 fine sand). 99 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 100 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 101 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 102 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 103 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Ordinary roack 104 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 105 Providing and fixing soil, waste and vent pipes : 100 mm dia. : 106 Sand cast iron S&S pipe as per IS: 1729. 107 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 108 Circular shape 450 mm dia 109 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 110 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 111 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 112 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 113 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm : 114 Sand cast iron S&S as per IS - 1729 115 Providing and fixing plain bend of required degree : 100 mm 116 Sand cast iron S&S as per IS - 1729 117 Providing and fixing single equal plain junction of required degree: 100x100x100mm, 118 Sand cast iron S&S as per IS-1729. 119 Providing and fixing terminal guard: 100mm : 120 Sand cast iron S&S as per IS:1729. 121 Providing and fixing collar:100mm : 122 Sand cast iron S&S as per IS:1729. 123 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 124 100mm : 125 Providing and fixing trap of self cleanising design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100mm inlet and 100mm outlet : 126 Sand cast iron S&S as per IS:3989. 127 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 128 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 129 25mm dia nominal bore. 130 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tees including cutting andthreading the pipe etc. complete : 131 25 to 40mm nominal bore. 132 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 133 32mm dia nominal bore. 134 Providing and fixing C.P. brass bib cock of approved quality confirming to IS :8931 : 135 15mm nominal bore. 136 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confirming to IS:8931 : 137 15mm nominal bore. 138 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 139 25mm nominal bore. 140 Providing and fixing ball valve (brass) of approved quality, High or low pressure with plastic floats : 141 25mm nominal bore. 142 Providing and fixing brass ferrule C.I. mouth cover including boring and taping the main : 143 25mm nominal bore. 144 Providing and fixing unplasticised PVC connection pipe with brass unions : 45cm length : 145 15mm nominal bore. 146 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 147 Providing and fixing PTMT grating of approved quality and colour : Circular type : 148 100mm nominal dia. 149 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer : E.R.W. tubes. 150 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 151 Size of tile600x600mm. 152 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.Single socketed pipes : 153 110mm diameter. 154 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Bend 87. 5° : 155 110mm bend. 156 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Shoe (Plain) : 157 110mm Shoe. 158 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 159 Two or more coats on new work. 160 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : 161 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 162 Providing and laying in position ready mixedor site batched design mix cement concrete for plain cement concrete work;usingcoarse aggregateandfine aggregate derived from natural sources and usingrecycled concrete aggregate (RCA)as coarse aggregate and fine aggregate within thepermissible utilization,PortlandPozzolana / Ordinary Portland/Portland Slag cement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concreteto improvedurability andworkabilitywithout impairing strength;including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishingas per direction of the engineer-in-charge; for thefollowing grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level 163 Concrete of M25 grade with minimum cement content of 300 kg /cum.(Note: The permissible utilization of Recycled Concrete Aggregate (RCA) as coarse aggregate and fine aggregate is 25% each). 164 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: 165 With 20x20 mm square bar 166 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 167 450 mm dia Ductile Iron Class K-9 pipes. *For use of bigger dia. pipes other than 450mm, net difference in basic rate as per applicable DSR shall be reimbursed to the contractor. 168 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 169 (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.Using rough kota stone. 170 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : 171 Using rough Kota stone 172 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 173 Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : 174 Red sand stone slab40 to 50 mm thick 175 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 176 40 to 50 mm thick 177 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 178 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 179 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 180 Made of G.I. wire of dia 4 mm 181 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 182 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) 183 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 Modified estimated cost after using correction factor on DSR-2023 on account of GST @0.973 vide O.M. dated 08.08.2024.(i.e. 9720555 *0.973 = 9458100 185 Carrying out structural analysis and design of all civil work, Design of all E&M works, foundation and superstructure of work such as pump-room, UGT and Delivery line upto Barapullah Drainage etc. all complete and submission of input data, check print structural drawing, 6 Nos. prints with soft copy of analysis and drawings as per direction of Engineer-in-Charge by approved structural consultant agency. The profile of structural consultant shall be got approved from NIT approving authority. The structural design shall be comprehensive to enable easy servicing of pumps and other heavy equipment’s etc. possible. The Hydrological data shall be provided to the consultant for drainage design.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
4.
Educational and Research Institute #10400896 Price Bid
Procurement, Installation And Maintenance Of Technical Equipment And Consumables , Category 1: Technical Equipment’S (Instruments) , Total Station Measuring Range Upto 10Km, Digital Display 1000M, Accuracy-2Mm+2Ppm, Diameter Of Raster Disc-79Mm, Operational Time-20Hrs, Weight- 5.7Kg, Dimension- 160Mm*150Mm*330Mm. , Raised Relief Model 1. 3D India Physical Map Size-75Cm*100Cm In English Font (Plastic) 2. 3D World Physical Map 105Cm *60Cm In English Font (Plastic) 3. Ocean Feature Model- Size 45*60Cm 4. Hydrological Model- Size 45*60 Cm3. 3D Model 112*162Cm Size- The Impact Of Erosion Model, The Earth: Tectonic Plates, Layer Of The Earths Atmosphere, The Shoreline Model, Slope: Dynamic,System River System,Desert Features: Wind System, Mass Movement On Earth, Cycle Of Erosion, Deformation Of Earth , Sea And Land Breez, Fold And Faults, Earths Interior, Glacier Landscape, Volcanic System, Contour Interpretation, , Geological Specimen For Demonstration 1. Rocks Andminerals Of Large Size (Set Of 50)2. Igneous Rock Of Small Size (Set Of 15) 3. Sedimentary Rock Of Small Size(Set Of 15) 4. Metamorphic Rock Of Small Size(Set Of 15) 5. Stones And Gems Of Small Size (Set Of 20Each) 6. Mohs Scale Of Hardness (With Magnet, Streak Plate And Hand Lense (Set Of 9) , Weather Station Model (Working Model) - Fully Assembled And Well Equipped Weather Kit 1. Rain Gauge Made By Fiber With Measuring Jar 2. Cup Anemometer 3. Wind Vane 4. Thermometer(Minimum And Maximum) 5. Stevenson Screen 6. Pan Evaporimeter 7. Sun Shine Recorder , Satellite Images (4*4 Feet Fiber Frame) High Resolution Satellite Images With Fiber Frame(Panaji-City) High Resolution Satellite Images With Fiber Frame (Porvorm-City) High Resolution Satellite Images With Fiber Frame (Margao-City) High Resolution Satellite Images With Fiber Frame (Mapusa-City) (Pan+ Liss Iv Merge Image) , Handheld Gps Receiver:Etrex 22* “Garmin” Etrex 22X, 33X, 10”, Se” Garmin, Display Type-2.2 Inch, Display Resolution-240*320 Pixel, Memory-8Gb, Battery Life 25 Hours, Gps Compass, Gps And Glonass Receiver And Gagan Enabled. Water Proof, Way Point- 2000 , Telescope Celestron Nextar 6Se Computorized Telescope , Binoculars 10X90x80 Bushnell Binoculars Very Superior
Contract Date: Ref. Documents Contract Value : Ref. Document
Private Organizations No of Bidders 3
5.
Housing Urban and Rular Development #9481199 Technical Bid
Tender For Special Repair& Maintenancework At Jnv Gumla, Jharkhand. - SCHOOL BUILDING 2 Structural Repair & Retrofitting 3 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 4 50mm average thickness 5 25 mm average thickness 6 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 7 Bars upto 12 mm diameter 8 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 9 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 10 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 12 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 13 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 14 Expansion Joint Treatment 15 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). 16 Floor Joint of 100 mm gap 17 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 18 Wall Joint of 100 mm gap 19 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 20 Roof Joint of 100 mm gap 21 Repairs to Roof 22 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 23 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 24 Repair to Toilets 25 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 26 For thickness of tiles 10 mm to 25 mm 27 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 28 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 29 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) 30 Providing and filling of cinder in sunken portion. 31 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 32 75 to 80 mm dia pipe 33 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 34 15 mm to 40 mm nominal bore 35 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 36 Up to 150 mm diameter 37 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 38 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 39 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 40 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 41 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 42 Rectangular manhole 90x80 cm and 45 cm deep 43 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 44 110 mm diameter 45 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 46 a) Coupler 47 110 mm 48 b) Bend 87.5° 49 110 mm bend 50 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 51 75 mm diameter pipes 52 100 mm diameter pipes 53 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 54 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 55 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 56 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 57 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 58 10 litre capacity - White 59 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 60 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 61 a) 32mm dia (for wash basin) 62 b) 40mm dia (for sink and urinal) 63 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 64 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 65 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 66 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 67 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 68 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 69 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 70 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 71 P-Trap type Floor Trap 110 x 75 mm 72 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 73 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 74 Providing and fixing 100 mm sand cast Iron grating for gully trap. 75 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 76 Providing & fixing soil, waste and vent pipes. 77 a) 100mm dia centrifugally cast iron S & S pipe. 78 b)75mm dia centrifugally cast iron S & S pipe. 79 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 80 a) for 100mm dia pipe. 81 b) for 75mm dia pipe. 82 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 83 a) 100mm 84 Sand cast iron S&S as per IS - 3989 85 b) 75mm 86 Sand cast iron S&S as per IS- 3989 87 Providing and fixing plaincast iron S & S sanitary bend. 88 a) 100mm 89 Sand cast iron S&S as per IS - 1729 90 b) 75mm 91 Sand cast iron S&S as per IS - 3989 92 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 93 a) 100x100x100mm 94 b) 75x75x75mm 95 Providing and fixingcast iron terminal guard. 96 a) 100mm 97 b) 75mm 98 Providing & fixingcast iron coller. 99 a)100 mm 100 Sand cast iron S&S as per IS - 3989 101 b)75mm dia. 102 Sand cast iron S&S as per IS - 3989 103 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 104 a) 100mm 105 b) 75mm 106 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 107 a) 100mm inlet & 75mm outlet. 108 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. 109 Providing and fixing PTMT urinal cock of approved quality and colour. 110 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms 111 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 112 15 mm nominal outer dia Pipes 113 20 mm nominal outer dia Pipes 114 25 mm nominal outer dia Pipes 115 32 mm nominal outer dia Pipes 116 Providing and fixing brass stop cock of approved quality. 117 15 mm nominal bore 118 Providing and fixing gun metal gate valve with wheel of approved quality. 119 a) 25mm dia nominal bore 120 b) 32mm dia nominal bore 121 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 122 a) 25mm. Nominal bore 123 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 124 a) 15mm nominal bore 125 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 126 a) 15mm nominal bore 127 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 128 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 129 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 130 a) 15mm nominal bore 131 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 132 a) 15mm nominal bore 133 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 134 15mm nominal bore 135 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 136 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 137 25mm nominal bore, weighing not less than 62 gms 138 Cutting holes up to 30x30 cm in walls including making good the same: 139 With common burnt clay F.P.S. (non modular) bricks 140 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 141 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 142 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 143 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 144 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 145 Repair to Plaster and Plinth Protection 146 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 147 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 148 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 149 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 150 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 151 With cement mortar 1:4 (1cement: 4 coarse sand) 152 15mm cement plaster of mix : 153 1:6 (1 cement : 6 course sand) 154 6mm cement plaster to ceiling of mix : 155 1:3 ( 1 cement : 3 fine sand) 156 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 157 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 158 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 159 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 160 Old work (one or more coats) 161 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 162 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 163 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 164 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface 165 Repairs to Door / Windows 166 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 167 Of area 3 sq. metres and below 168 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 169 Of area 3 sq. metres and below 170 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 171 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 172 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 173 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 174 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete 175 Fixed to steel windows by welding 176 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 177 300 mm weighing not less than 200gms. 178 250 mm weighing not less than 150gms. 179 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 180 100X58X1.90 mm 181 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 182 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 183 300 x 10mm 184 200 x 10mm 185 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 186 125 mm 187 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 188 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 189 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 190 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 191 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 192 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 193 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 194 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 195 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 196 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 197 4.0 mm thick glass panes 198 Applying priming coat : 199 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 200 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 201 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 202 Two or more coats on new work 203 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 204 One or more coats on old work 205 Repairs to Flooring 206 Miscellaneous 207 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 208 In cement mortar 209 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 210 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 211 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 212 Edges of slabs and breaks in floors and walls 213 Under 20 cm wide 214 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 215 Suspended floors, roofs, landings, balconies and access platform. 216 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 217 Thermo-Mechanically Treated bars of grade Fe-500D or more. 218 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 219 Cement mortar 1:6 (1 cement : 6 coarse sand) 220 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 221 Cement mortar 1:4 (1 cement :4 coarse sand 222 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 223 ELECTRICAL WORK OF SCHOOL BUILDING 224 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 225 Group C 226 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 227 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 228 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 229 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 230 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 231 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 232 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 233 Group C 234 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 235 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 236 2 x 1.5 sq. mm 237 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 32 mm 240 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 241 100 mm X 100 mm X 60 mm deep 242 150 mm X 75 mm X 60 mm deep 243 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 244 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 245 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 246 Supplying and fixing brass batten/ angle holder including connection etc. as required. 247 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 248 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 249 4 way (4 + 12), Double door 250 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 251 Single pole 252 Single pole and neutral 253 Triple pole 254 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 255 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 256 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 257 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 258 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 259 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 260 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 261 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 262 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 263 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 264 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 265 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 266 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 267 MP HALL 268 Repairs to Roof: 269 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 270 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 271 Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 272 Repair to Plaster and Plinth Protection 273 12 mm cement plaster of mix : 274 1:6 (1 cement : 6 course sand) 275 White washing with lime to give an even shade: 276 New work (three or more coats) 277 Repairs to Door / Windows 278 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 279 Of area 3 sq. metres and below 280 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 281 Of area 3 sq. metres and below 282 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 283 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete 284 Fixed to steel windows by welding 285 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 286 300 mm weighing not less than 200gms. 287 250 mm weighing not less than 150gms. 288 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 289 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 290 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 291 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 292 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 293 4.0 mm thick glass panes 294 Applying priming coat : 295 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 296 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 297 Two or more coats on new work 298 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 299 One or more coats on old work 300 Miscellaneous 301 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 302 In cement mortar 303 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 304 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 305 Cement mortar 1:6 (1 cement : 6 coarse sand) 306 Boys Dormitories(CBRI Type) - 6 Blocks, Total Beds= 6x40 =240 307 Structural Repair & Retrofitting 308 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 309 50mm average thickness 310 25 mm average thickness 311 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 312 Bars upto 12 mm diameter 313 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 314 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 315 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 316 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 317 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 318 Re-Baring of MS bar 10 mm dia with Fisher Chaemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 319 Repairs to Roof 320 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 321 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 322 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 323 Repair to Toilets 324 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 325 For thickness of tiles 10 mm to 25 mm 326 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 327 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 328 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 329 Providing and filling of cinder in sunken portions. 330 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 331 75 to 80 mm dia pipe 332 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 333 15 mm to 40 mm nominal bore 334 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 335 Up to 150 mm diameter 336 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 337 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 338 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 339 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 340 Up to 150 mm diameter 341 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 342 Rectangular manhole 90x80 cm and 45 cm deep 343 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 344 110 mm diameter 345 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 346 a) Coupler 347 110 mm 348 b) Bend 87.5° 349 110 mm bend 350 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 351 75 mm diameter pipes 352 100 mm diameter pipes 353 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 354 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 355 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 356 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 357 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 358 a) 32mm dia (for wash basin) 359 b) 40mm dia (for sink and urinal) 360 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 361 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 362 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 363 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 364 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 365 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 366 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 367 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 368 P-Trap type Floor Trap 110 x 75 mm 369 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 370 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 371 Providing and fixing 100 mm sand cast Iron grating for gully trap. 372 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 373 Providing & fixing soil, waste and vent pipes. 374 a) 100mm dia centrifugally cast iron S & S pipe. 375 b)75mm dia centrifugally cast iron S & S pipe. 376 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 377 a) for 100mm dia pipe. 378 b) for 75mm dia pipe. 379 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 380 a) 100mm 381 Sand cast iron S&S as per IS - 3989 382 b) 75mm 383 Sand cast iron S&S as per IS- 3989 384 Providing and fixing plaincast iron S & S sanitary bend. 385 a) 100mm 386 Sand cast iron S&S as per IS - 1729 387 b) 75mm 388 Sand cast iron S&S as per IS - 3989 389 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 390 a) 100x100x100mm 391 b) 75x75x75mm 392 Providing and fixingcast iron terminal guard. 393 a) 100mm 394 b) 75mm 395 Providing & fixingcast iron coller. 396 a)100 mm 397 Sand cast iron S&S as per IS - 3989 398 b)75mm dia. 399 Sand cast iron S&S as per IS - 3989 400 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 401 a) 100mm 402 b) 75mm 403 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 404 a) 100mm inlet & 75mm outlet. 405 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 406 15 mm nominal outer dia Pipes 407 20 mm nominal outer dia Pipes 408 25 mm nominal outer dia Pipes 409 32 mm nominal outer dia Pipes 410 Providing and fixing brass stop cock of approved quality. 411 15 mm nominal bore 412 Providing and fixing gun metal gate valve with wheel of approved quality. 413 a) 25mm dia nominal bore 414 b) 32mm dia nominal bore 415 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 416 a) 25mm. Nominal bore 417 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 418 a) 15mm nominal bore 419 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 420 a) 15mm nominal bore 421 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 422 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 423 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 424 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 425 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 426 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 427 a) 15mm nominal bore 428 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 429 a) 15mm nominal bore 430 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 431 15mm nominal bore 432 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 433 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 434 25mm nominal bore, weighing not less than 62 gms 435 Cutting holes up to 30x30 cm in walls including making good the same: 436 With common burnt clay F.P.S. (non modular) bricks 437 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 438 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 439 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 440 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 441 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 442 Repair to Plaster and Plinth Protection 443 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 444 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 445 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 446 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 447 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 448 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 449 With cement mortar 1:4 (1cement: 4 coarse sand) 450 12mm cement plaster of mix : 451 1:6 (1 cement : 6 course sand) 452 6mm cement plaster to ceiling of mix : 453 1:3 ( 1 cement : 3 fine sand) 454 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 455 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 456 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 457 Old work (one or more coats) 458 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 459 Repairs to Door / Windows 460 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 461 Of area 3 sq. metres and below 462 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 463 Of area 3 sq. metres and below 464 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 465 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 466 Renewal of old putty of glass panes (length) 467 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 468 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 469 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 470 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 471 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 472 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 473 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 474 With 12 mm mild steel U beading 475 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 476 300 mm weighing not less than 200gms. 477 250 mm weighing not less than 150gms. 478 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 479 100X58X1.90 mm 480 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 481 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 482 300 x 10mm 483 150 x 10mm 484 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 485 125 mm 486 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 487 Using flats 30x6mm for diagonal braces and central cross piece 488 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 489 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 490 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 491 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 492 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 493 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 494 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 495 4.0 mm thick glass panes 496 Applying priming coat : 497 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 498 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 499 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 500 Two or more coats on new work 501 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 502 One or more coats on old work 503 Miscellaneous 504 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 505 In cement mortar 506 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 507 Cement mortar 1:6 (1 cement : 6 coarse sand) 508 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 509 Cement mortar 1:4 (1 cement :4 coarse sand 510 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 511 ELECTRICAL WORK OF BOYS DORMITORY 512 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 513 Group B 514 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 515 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 516 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 517 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 518 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 519 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 520 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 521 Group B 522 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 523 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 524 2 x 1.5 sq. mm 525 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 526 25 mm 527 32 mm 528 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 529 100 mm X 100 mm X 60 mm deep 530 150 mm X 75 mm X 60 mm deep 531 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 532 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 533 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 534 Supplying and fixing brass batten/ angle holder including connection etc. as required. 535 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 536 4 way (4 + 12), Double door 537 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 538 Single pole 539 Single pole and neutral 540 Triple pole 541 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 542 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 543 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 544 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 545 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 546 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 547 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 548 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 549 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 550 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 551 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 552 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 553 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 554 GIRLS - 40 (CBRI) - 2 BLOCKS 555 Structural Repair & Retrofitting 556 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 557 50mm average thickness 558 25 mm average thickness 559 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 560 Bars upto 12 mm diameter 561 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 562 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 563 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 564 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 565 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 566 Re-Baring of MS bar 10 mm dia with Fisher Chaemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 567 Repairs to Roof 568 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 569 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 570 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 571 Repair to Toilets 572 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 573 For thickness of tiles 10 mm to 25 mm 574 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 575 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 576 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 577 Providing and filling of cinder in sunken portions. 578 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 579 75 to 80 mm dia pipe 580 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 581 15 mm to 40 mm nominal bore 582 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 583 Up to 150 mm diameter 584 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 585 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 586 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 587 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 588 Up to 150 mm diameter 589 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 590 Rectangular manhole 90x80 cm and 45 cm deep 591 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 592 110 mm diameter 593 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 594 a) Coupler 595 110 mm 596 b) Bend 87.5° 597 110 mm bend 598 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 599 75 mm diameter pipes 600 100 mm diameter pipes 601 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 602 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 603 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 604 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 605 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 606 a) 32mm dia (for wash basin) 607 b) 40mm dia (for sink and urinal) 608 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 609 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 610 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 611 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 612 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 613 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 614 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 615 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 616 P-Trap type Floor Trap 110 x 75 mm 617 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 618 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 619 Providing and fixing 100 mm sand cast Iron grating for gully trap. 620 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 621 Providing & fixing soil, waste and vent pipes. 622 a) 100mm dia centrifugally cast iron S & S pipe. 623 b)75mm dia centrifugally cast iron S & S pipe. 624 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 625 a) for 100mm dia pipe. 626 b) for 75mm dia pipe. 627 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 628 a) 100mm 629 Sand cast iron S&S as per IS - 3989 630 b) 75mm 631 Sand cast iron S&S as per IS- 3989 632 Providing and fixing plaincast iron S & S sanitary bend. 633 a) 100mm 634 Sand cast iron S&S as per IS - 1729 635 b) 75mm 636 Sand cast iron S&S as per IS - 3989 637 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 638 a) 100x100x100mm 639 b) 75x75x75mm 640 Providing and fixingcast iron terminal guard. 641 a) 100mm 642 b) 75mm 643 Providing & fixingcast iron coller. 644 a)100 mm 645 Sand cast iron S&S as per IS - 3989 646 b)75mm dia. 647 Sand cast iron S&S as per IS - 3989 648 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 649 a) 100mm 650 b) 75mm 651 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 652 a) 100mm inlet & 75mm outlet. 653 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 654 15 mm nominal outer dia Pipes 655 20 mm nominal outer dia Pipes 656 25 mm nominal outer dia Pipes 657 32 mm nominal outer dia Pipes 658 Providing and fixing brass stop cock of approved quality. 659 15 mm nominal bore 660 Providing and fixing gun metal gate valve with wheel of approved quality. 661 a) 25mm dia nominal bore 662 b) 32mm dia nominal bore 663 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 664 a) 25mm. Nominal bore 665 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 666 a) 15mm nominal bore 667 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 668 a) 15mm nominal bore 669 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 670 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 671 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 672 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 673 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 674 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 675 a) 15mm nominal bore 676 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 677 a) 15mm nominal bore 678 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 679 15mm nominal bore 680 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 681 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 682 25mm nominal bore, weighing not less than 62 gms 683 Cutting holes up to 30x30 cm in walls including making good the same: 684 With common burnt clay F.P.S. (non modular) bricks 685 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 686 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 687 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 688 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 689 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 690 Repair to Plaster and Plinth Protection 691 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 692 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 693 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 694 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 695 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 696 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 697 With cement mortar 1:4 (1cement: 4 coarse sand) 698 12mm cement plaster of mix : 699 1:6 (1 cement : 6 course sand) 700 6mm cement plaster to ceiling of mix : 701 1:3 ( 1 cement : 3 fine sand) 702 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 703 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 704 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 705 Old work (one or more coats) 706 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 707 Repairs to Door / Windows 708 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 709 Of area 3 sq. metres and below 710 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 711 Of area 3 sq. metres and below 712 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 713 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 714 Renewal of old putty of glass panes (length) 715 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 716 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 717 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 718 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 720 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 721 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 722 With 12 mm mild steel U beading 723 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 724 300 mm weighing not less than 200gms. 725 250 mm weighing not less than 150gms. 726 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 727 100X58X1.90 mm 728 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 729 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 730 300 x 10mm 731 150 x 10mm 732 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 733 125 mm 734 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 735 Using flats 30x6mm for diagonal braces and central cross piece 736 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 737 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 738 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 739 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 740 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 741 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 742 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 743 4.0 mm thick glass panes 744 Applying priming coat : 745 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 746 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 747 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 748 Two or more coats on new work 749 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 750 One or more coats on old work 751 Miscellaneous 752 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 753 In cement mortar 754 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 755 Cement mortar 1:6 (1 cement : 6 coarse sand) 756 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 757 Cement mortar 1:4 (1 cement :4 coarse sand 758 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 759 ELECTRICAL WORK OF GIRLS - 40 (CBRI) - 2 BLOCKS 760 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 761 Group B 762 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 763 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 764 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 765 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 766 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 767 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 768 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 769 Group B 770 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 771 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 772 2 x 1.5 sq. mm 773 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 774 25 mm 775 32 mm 776 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 777 100 mm X 100 mm X 60 mm deep 778 150 mm X 75 mm X 60 mm deep 779 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 780 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 781 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 782 Supplying and fixing brass batten/ angle holder including connection etc. as required. 783 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 784 4 way (4 + 12), Double door 785 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 786 Single pole 787 Single pole and neutral 788 Triple pole 789 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 790 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 791 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 792 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 793 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 794 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 795 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 796 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 797 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 798 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 799 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 800 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 801 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 802 Girls Dormitories(CPWD Type) 1 Block 803 Structural Repair & Retrofitting 804 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 805 50mm average thickness 806 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 807 Bars upto 12 mm diameter 808 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 809 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 810 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 811 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 812 Repairs to Roof 813 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 814 In cement mortar 815 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 816 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 817 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 818 Repair to Toilets 819 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 820 For thickness of tiles 10 mm to 25 mm 821 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 822 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 823 75 to 80 mm dia pipe 824 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 825 15 mm to 40 mm nominal bore 826 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 827 Up to 150 mm diameter 828 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 829 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 830 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 831 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 832 Up to 150 mm diameter 833 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 834 Rectangular manhole 90x80 cm and 45 cm deep 835 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 836 110 mm diameter 837 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 838 a) Coupler 839 110 mm 840 b) Bend 87.5° 841 110 mm bend 842 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 843 75 mm diameter pipes 844 100 mm diameter pipes 845 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 846 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 847 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 848 W.C. pan with ISI marked white solid plastic seat and lid 849 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 850 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 851 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 852 a) 32mm dia (for wash basin) 853 b) 40mm dia (for sink and urinal) 854 Providing & fixing C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. 855 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 856 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 857 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 858 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 859 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 860 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 861 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 862 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 863 P-Trap type Floor Trap 110 x 75 mm 864 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 865 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 866 Providing and fixing 100 mm sand cast Iron grating for gully trap. 867 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 868 Providing and fixing toilet paper holder : 869 Vitreous china 870 Providing & fixing soil, waste and vent pipes. 871 a) 100mm dia centrifugally cast iron S & S pipe. 872 b)75mm dia centrifugally cast iron S & S pipe. 873 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 874 a) for 100mm dia pipe. 875 b) for 75mm dia pipe. 876 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 877 a) 100mm 878 Sand cast iron S&S as per IS - 3989 879 b) 75mm 880 Sand cast iron S&S as per IS- 3989 881 Providing and fixing plaincast iron S & S sanitary bend. 882 a) 100mm 883 Sand cast iron S&S as per IS - 1729 884 b) 75mm 885 Sand cast iron S&S as per IS - 3989 886 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 887 a) 100x100x100mm 888 b) 75x75x75mm 889 Providing and fixingcast iron terminal guard. 890 a) 100mm 891 b) 75mm 892 Providing & fixingcast iron coller. 893 a)100 mm 894 Sand cast iron S&S as per IS - 3989 895 b)75mm dia. 896 Sand cast iron S&S as per IS - 3989 897 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 898 a) 100mm 899 b) 75mm 900 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 901 a) 100mm inlet & 75mm outlet. 902 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 903 15 mm nominal outer dia Pipes 904 20 mm nominal outer dia Pipes 905 25 mm nominal outer dia Pipes 906 32 mm nominal outer dia Pipes 907 Providing and fixing brass stop cock of approved quality. 908 15 mm nominal bore 909 Providing and fixing gun metal gate valve with wheel of approved quality. 910 a) 25mm dia nominal bore 911 b) 32mm dia nominal bore 912 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 913 a) 25mm. Nominal bore 914 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 915 a) 15mm nominal bore 916 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 917 a) 15mm nominal bore 918 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 919 a) 15mm nominal bore 920 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 921 a) 15mm nominal bore 922 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 923 15mm nominal bore 924 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 925 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 926 25mm nominal bore, weighing not less than 62 gms 927 Cutting holes up to 30x30 cm in walls including making good the same: 928 With common burnt clay F.P.S. (non modular) bricks 929 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 930 Repair to Plaster and Plinth Protection 931 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 932 Two or more coats on new work 933 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 934 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 935 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 936 15mm cement plaster on rough side of single or half brick wall of mix 937 1:6 (1 cement : 6 course sand) 938 6mm cement plaster to ceiling of mix : 939 1:3 ( 1 cement : 3 fine sand) 940 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 941 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 942 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 943 Old work (one or more coats) 944 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 945 Repairs to Door / Windows 946 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 947 Of area 3 sq. metres and below 948 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 949 Of area 3 sq. metres and below 950 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 951 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 952 Renewal of old putty of glass panes (length) 953 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 954 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 955 250 mm weighing not less than 150gms. 956 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 957 100X58X1.90 mm 958 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 959 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 960 300 x 10mm 961 150 x 10mm 962 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 963 125 mm 964 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 965 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 966 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 967 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 968 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 969 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 970 With 12 mm mild steel U beading 971 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 972 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 973 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 974 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 975 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 976 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 977 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 978 4.0 mm thick glass panes 979 Applying priming coat : 980 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 981 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 982 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 983 Two or more coats on new work 984 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 985 One or more coats on old work 986 Miscellaneous 987 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 988 In cement mortar 989 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 990 Cement mortar 1:6 (1 cement : 6 coarse sand) 991 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 992 Cement mortar 1:4 (1 cement :4 coarse sand 993 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 994 ELECTRICAL WORK OF GIRLSDORMITORY (G) FOR 48 STUDENTS 995 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 996 Group B 997 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 998 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 999 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1000 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1001 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1002 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1003 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1004 Group B 1005 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1006 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1007 2 x 1.5 sq. mm 1008 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1009 25 mm 1010 32 mm 1011 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1012 100 mm X 100 mm X 60 mm deep 1013 150 mm X 75 mm X 60 mm deep 1014 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1015 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1016 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1017 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1018 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1019 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1020 4 way (4 + 12), Double door 1021 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1022 Single pole 1023 Single pole and neutral 1024 Triple pole 1025 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1026 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1027 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1028 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1029 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1030 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1031 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1032 BOYS DORM - CPWD ( 1 BLOCK) 1033 Structural Repair & Retrofitting 1034 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1035 50mm average thickness 1036 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1037 Bars upto 12 mm diameter 1038 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1039 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1040 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1041 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1042 Repairs to Roof 1043 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1044 In cement mortar 1045 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1046 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1047 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1048 Repair to Toilets 1049 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1050 For thickness of tiles 10 mm to 25 mm 1051 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1052 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1053 75 to 80 mm dia pipe 1054 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1055 15 mm to 40 mm nominal bore 1056 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1057 Up to 150 mm diameter 1058 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1059 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1060 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1061 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1062 Up to 150 mm diameter 1063 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1064 Rectangular manhole 90x80 cm and 45 cm deep 1065 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1066 110 mm diameter 1067 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1068 a) Coupler 1069 110 mm 1070 b) Bend 87.5° 1071 110 mm bend 1072 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1073 75 mm diameter pipes 1074 100 mm diameter pipes 1075 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1076 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1077 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1078 W.C. pan with ISI marked white solid plastic seat and lid 1079 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1080 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1081 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1082 a) 32mm dia (for wash basin) 1083 b) 40mm dia (for sink and urinal) 1084 Providing & fixing C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. 1085 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1086 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 1087 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1088 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1089 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1090 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1091 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1092 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1093 P-Trap type Floor Trap 110 x 75 mm 1094 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1095 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1096 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1097 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1098 Providing and fixing toilet paper holder : 1099 Vitreous china 1100 Providing & fixing soil, waste and vent pipes. 1101 a) 100mm dia centrifugally cast iron S & S pipe. 1102 b)75mm dia centrifugally cast iron S & S pipe. 1103 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1104 a) for 100mm dia pipe. 1105 b) for 75mm dia pipe. 1106 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1107 a) 100mm 1108 Sand cast iron S&S as per IS - 3989 1109 b) 75mm 1110 Sand cast iron S&S as per IS- 3989 1111 Providing and fixing plaincast iron S & S sanitary bend. 1112 a) 100mm 1113 Sand cast iron S&S as per IS - 1729 1114 b) 75mm 1115 Sand cast iron S&S as per IS - 3989 1116 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1117 a) 100x100x100mm 1118 b) 75x75x75mm 1119 Providing and fixingcast iron terminal guard. 1120 a) 100mm 1121 b) 75mm 1122 Providing & fixingcast iron coller. 1123 a)100 mm 1124 Sand cast iron S&S as per IS - 3989 1125 b)75mm dia. 1126 Sand cast iron S&S as per IS - 3989 1127 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1128 a) 100mm 1129 b) 75mm 1130 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1131 a) 100mm inlet & 75mm outlet. 1132 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1133 15 mm nominal outer dia Pipes 1134 20 mm nominal outer dia Pipes 1135 25 mm nominal outer dia Pipes 1136 32 mm nominal outer dia Pipes 1137 Providing and fixing brass stop cock of approved quality. 1138 15 mm nominal bore 1139 Providing and fixing gun metal gate valve with wheel of approved quality. 1140 a) 25mm dia nominal bore 1141 b) 32mm dia nominal bore 1142 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1143 a) 25mm. Nominal bore 1144 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1145 a) 15mm nominal bore 1146 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1147 a) 15mm nominal bore 1148 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1149 a) 15mm nominal bore 1150 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1151 a) 15mm nominal bore 1152 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1153 15mm nominal bore 1154 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1155 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1156 25mm nominal bore, weighing not less than 62 gms 1157 Cutting holes up to 30x30 cm in walls including making good the same: 1158 With common burnt clay F.P.S. (non modular) bricks 1159 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1160 Repair to Plaster and Plinth Protection 1161 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. 1162 Two or more coats on new work 1163 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1164 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1165 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1166 15mm cement plaster on rough side of single or half brick wall of mix 1167 1:6 (1 cement : 6 course sand) 1168 6mm cement plaster to ceiling of mix : 1169 1:3 ( 1 cement : 3 fine sand) 1170 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1171 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1172 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1173 Old work (one or more coats) 1174 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1175 Repairs to Door / Windows 1176 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1177 Of area 3 sq. metres and below 1178 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1179 Of area 3 sq. metres and below 1180 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 1181 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1182 Renewal of old putty of glass panes (length) 1183 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 1184 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1185 250 mm weighing not less than 150gms. 1186 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1187 100X58X1.90 mm 1188 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1189 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1190 300 x 10mm 1191 150 x 10mm 1192 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1193 125 mm 1194 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1195 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1196 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1197 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1198 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1199 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 1200 With 12 mm mild steel U beading 1201 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1202 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1203 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 1204 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1205 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1206 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1207 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1208 4.0 mm thick glass panes 1209 Applying priming coat : 1210 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1211 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1212 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1213 Two or more coats on new work 1214 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1215 One or more coats on old work 1216 Repairs to Flooring 1217 Miscellaneous 1218 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1219 In cement mortar 1220 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1221 Cement mortar 1:6 (1 cement : 6 coarse sand) 1222 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1223 Cement mortar 1:4 (1 cement :4 coarse sand 1224 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1225 ELECTRICAL WORK OF BOYS DORM - 24 CPWD ( 1 BLOCK) 1226 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1227 Group B 1228 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1229 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1230 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1231 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1232 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1233 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1234 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1235 Group B 1236 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1237 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1238 2 x 1.5 sq. mm 1239 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1240 25 mm 1241 32 mm 1242 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1243 100 mm X 100 mm X 60 mm deep 1244 150 mm X 75 mm X 60 mm deep 1245 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1246 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1247 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1248 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1249 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1250 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1251 4 way (4 + 12), Double door 1252 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1253 Single pole 1254 Single pole and neutral 1255 Triple pole 1256 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1257 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1258 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1259 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1260 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1261 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1262 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1263 Staff Qtrs Type-III . (12 nos. i.e. 3 blocks of four unit each) G+1 1264 Structural Repair & Retrofitting 1265 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1266 25 mm average thickness 1267 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1268 Bars upto 12 mm diameter 1269 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1270 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1271 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1272 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1273 Repairs to Roof 1274 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1275 In cement mortar 1276 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1277 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1278 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1279 Repair to Toilets 1280 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1281 For thickness of tiles 10 mm to 25 mm 1282 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1283 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1284 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1285 Providing and filling of cinder in sunken portions. 1286 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1287 75 to 80 mm dia pipe 1288 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1289 15 mm to 40 mm nominal bore 1290 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1291 Up to 150 mm diameter 1292 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1293 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1294 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1295 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1296 Up to 150 mm diameter 1297 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1298 Rectangular manhole 90x80 cm and 45 cm deep 1299 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1300 110 mm diameter 1301 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1302 a) Coupler 1303 110 mm 1304 b) Bend 87.5° 1305 110 mm bend 1306 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1307 75 mm diameter pipes 1308 100 mm diameter pipes 1309 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1310 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1311 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1312 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1313 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1314 Kitchen sink without drain board 1315 610x510 mm bowl depth 200 mm 1316 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1317 a) 32mm dia (for wash basin) 1318 b) 40mm dia (for sink and urinal) 1319 Providing & fixing CP brass Overhead shower with shower arm, Hand Shower 95mm dia Single Lever Concealed Deusch Mixer with Provision for Connection to Overhead Shower and Easy flex Tube with accessories complete I allrespect 1320 Providing and fixing of C. P. brass towel rail 600 x 20 mm size complete with C.P. brass brackets 1321 Providing and fixing of C. P. brass towel ring complete with C.P. brass brackets 1322 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1323 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1324 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1325 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1326 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1327 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1328 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1329 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1330 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1331 P-Trap type Floor Trap 110 x 75 mm 1332 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1333 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1334 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1335 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1336 Providing & fixing soil, waste and vent pipes. 1337 a) 100mm dia centrifugally cast iron S & S pipe. 1338 b)75mm dia centrifugally cast iron S & S pipe. 1339 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1340 a) for 100mm dia pipe. 1341 b) for 75mm dia pipe. 1342 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1343 a) 100mm 1344 Sand cast iron S&S as per IS - 3989 1345 b) 75mm 1346 Sand cast iron S&S as per IS- 3989 1347 Providing and fixing plaincast iron S & S sanitary bend. 1348 a) 100mm 1349 Sand cast iron S&S as per IS - 1729 1350 b) 75mm 1351 Sand cast iron S&S as per IS - 3989 1352 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1353 a) 100x100x100mm 1354 b) 75x75x75mm 1355 Providing and fixingcast iron terminal guard. 1356 a) 100mm 1357 b) 75mm 1358 Providing & fixingcast iron coller. 1359 a)100 mm 1360 Sand cast iron S&S as per IS - 3989 1361 b)75mm dia. 1362 Sand cast iron S&S as per IS - 3989 1363 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1364 a) 100mm 1365 b) 75mm 1366 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1367 a) 100mm inlet & 75mm outlet. 1368 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1369 15 mm nominal outer dia Pipes 1370 20 mm nominal outer dia Pipes 1371 25 mm nominal outer dia Pipes 1372 32 mm nominal outer dia Pipes 1373 Providing and fixing brass stop cock of approved quality. 1374 15 mm nominal bore 1375 Providing and fixing gun metal gate valve with wheel of approved quality. 1376 a) 25mm dia nominal bore 1377 b) 32mm dia nominal bore 1378 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1379 a) 25mm. Nominal bore 1380 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1381 a) 15mm nominal bore 1382 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1383 a) 15mm nominal bore 1384 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1385 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1386 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1387 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1388 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1389 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1390 a) 15mm nominal bore 1391 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1392 a) 15mm nominal bore 1393 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1394 a) 15mm nominal bore 1395 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1396 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1397 25mm nominal bore, weighing not less than 62 gms 1398 Cutting holes up to 30x30 cm in walls including making good the same: 1399 With common burnt clay F.P.S. (non modular) bricks 1400 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1401 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1402 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1403 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1404 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1405 Repair to Plaster and Plinth Protection 1406 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1407 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1408 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1409 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1410 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1411 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1412 With cement mortar 1:4 (1cement: 4 coarse sand) 1413 12mm cement plaster of mix : 1414 1:6 (1 cement : 6 course sand) 1415 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1416 Raised and cut pointing 1417 6mm cement plaster to ceiling of mix : 1418 1:3 ( 1 cement : 3 fine sand) 1419 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1420 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1421 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1422 Old work (one or more coats) 1423 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1424 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1425 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1426 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1427 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1428 Repairs to Door / Windows 1429 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1430 Of area 3 sq. metres and below 1431 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1432 Of area 3 sq. metres and below 1433 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1434 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1435 Renewal of old putty of glass panes (length) 1436 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding 1437 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1438 250 mm weighing not less than 150gms. 1439 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1440 100X58X1.90 mm 1441 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1442 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1443 300 x 10mm 1444 150 x 10mm 1445 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1446 125 mm 1447 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1448 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1449 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1450 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1451 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1452 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1453 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1454 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1455 4.0 mm thick glass panes 1456 Applying priming coat : 1457 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1458 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1459 Two or more coats on new work 1460 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1461 One or more coats on old work 1462 Miscellaneous 1463 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1464 Cement mortar 1:6 (1 cement : 6 coarse sand) 1465 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1466 Cement mortar 1:4 (1 cement :4 coarse sand 1467 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1468 ELECTRICAL WORK OF TYPE-III (G+1) 1469 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1470 Group B 1471 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1472 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1473 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1474 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1475 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1476 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1477 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1478 Group B 1479 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1480 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1481 2 x 1.5 sq. mm 1482 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1483 25 mm 1484 32 mm 1485 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1486 100 mm X 100 mm X 60 mm deep 1487 150 mm X 75 mm X 60 mm deep 1488 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1489 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1490 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1491 S/F light plug point Modular type accessories :- 1492 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1493 S/F power plug point modular type accessories :- 1494 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1495 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1496 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1497 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1498 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1499 6 way, Double door 1500 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1501 4 way (4 + 12), Double door 1502 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1503 Single pole 1504 Single pole and neutral 1505 Triple pole 1506 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1507 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1508 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1509 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1510 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1511 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1512 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1513 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1514 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1515 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1516 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1517 Type-II Staff Qtrs. (12 nos. i.e. 3 block of 4 unit each) G+1 1518 Structural Repair & Retrofitting 1519 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1520 25 mm average thickness 1521 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1522 Bars upto 12 mm diameter 1523 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1524 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1525 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1526 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1527 Repairs to Roof 1528 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 1529 In cement mortar 1530 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1531 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1532 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1533 Repair to Toilets 1534 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1535 For thickness of tiles 10 mm to 25 mm 1536 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1537 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1538 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1539 Providing and filling of cinder in sunken portions. 1540 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1541 75 to 80 mm dia pipe 1542 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1543 15 mm to 40 mm nominal bore 1544 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1545 Up to 150 mm diameter 1546 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1547 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1548 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1549 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1550 Up to 150 mm diameter 1551 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1552 Rectangular manhole 90x80 cm and 45 cm deep 1553 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1554 110 mm diameter 1555 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1556 a) Coupler 1557 110 mm 1558 b) Bend 87.5° 1559 110 mm bend 1560 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1561 75 mm diameter pipes 1562 100 mm diameter pipes 1563 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1564 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1565 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1566 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1567 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1568 Kitchen sink without drain board 1569 610x510 mm bowl depth 200 mm 1570 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1571 a) 32mm dia (for wash basin) 1572 b) 40mm dia (for sink and urinal) 1573 Providing & fixing CP brass Overhead shower with shower arm, Hand Shower 95mm dia Single Lever Concealed Deusch Mixer with Provision for Connection to Overhead Shower and Easy flex Tube with accessories complete I allrespect 1574 Providing and fixing of C. P. brass towel rail 600 x 20 mm size complete with C.P. brass brackets 1575 Providing and fixing of C. P. brass towel ring complete with C.P. brass brackets 1576 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1577 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1578 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1579 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1580 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1581 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1582 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1583 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1584 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1585 P-Trap type Floor Trap 110 x 75 mm 1586 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1587 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1588 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1589 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1590 Providing & fixing soil, waste and vent pipes. 1591 a) 100mm dia centrifugally cast iron S & S pipe. 1592 b)75mm dia centrifugally cast iron S & S pipe. 1593 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1594 a) for 100mm dia pipe. 1595 b) for 75mm dia pipe. 1596 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1597 a) 100mm 1598 Sand cast iron S&S as per IS - 3989 1599 b) 75mm 1600 Sand cast iron S&S as per IS- 3989 1601 Providing and fixing plaincast iron S & S sanitary bend. 1602 a) 100mm 1603 Sand cast iron S&S as per IS - 1729 1604 b) 75mm 1605 Sand cast iron S&S as per IS - 3989 1606 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1607 a) 100x100x100mm 1608 b) 75x75x75mm 1609 Providing and fixingcast iron terminal guard. 1610 a) 100mm 1611 b) 75mm 1612 Providing & fixingcast iron coller. 1613 a)100 mm 1614 Sand cast iron S&S as per IS - 3989 1615 b)75mm dia. 1616 Sand cast iron S&S as per IS - 3989 1617 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1618 a) 100mm 1619 b) 75mm 1620 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1621 a) 100mm inlet & 75mm outlet. 1622 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1623 15 mm nominal outer dia Pipes 1624 20 mm nominal outer dia Pipes 1625 25 mm nominal outer dia Pipes 1626 32 mm nominal outer dia Pipes 1627 Providing and fixing brass stop cock of approved quality. 1628 15 mm nominal bore 1629 Providing and fixing gun metal gate valve with wheel of approved quality. 1630 a) 25mm dia nominal bore 1631 b) 32mm dia nominal bore 1632 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1633 a) 25mm. Nominal bore 1634 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1635 a) 15mm nominal bore 1636 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1637 a) 15mm nominal bore 1638 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1639 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1640 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1641 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1642 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1643 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1644 a) 15mm nominal bore 1645 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1646 a) 15mm nominal bore 1647 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1648 a) 15mm nominal bore 1649 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1650 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1651 25mm nominal bore, weighing not less than 62 gms 1652 Cutting holes up to 30x30 cm in walls including making good the same: 1653 With common burnt clay F.P.S. (non modular) bricks 1654 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1655 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1656 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1657 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1658 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1659 Repair to Plaster and Plinth Protection 1660 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1661 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1662 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1663 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1664 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1665 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1666 With cement mortar 1:4 (1cement: 4 coarse sand) 1667 15mm cement plaster of mix : 1668 1:6 (1 cement : 6 course sand) 1669 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1670 Raised and cut pointing 1671 6mm cement plaster to ceiling of mix : 1672 1:3 ( 1 cement : 3 fine sand) 1673 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1674 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1675 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1676 Old work (one or more coats) 1677 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1678 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1679 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1680 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1681 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1682 Repairs to Door / Windows 1683 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1684 Of area 3 sq. metres and below 1685 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1686 Of area 3 sq. metres and below 1687 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1688 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1689 Renewal of old putty of glass panes (length) 1690 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding 1691 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1692 250 mm weighing not less than 150gms. 1693 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1694 100X58X1.90 mm 1695 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1696 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1697 300 x 10mm 1698 150 x 10mm 1699 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1700 125 mm 1701 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1702 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1703 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1704 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1705 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1706 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1707 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1708 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1709 4.0 mm thick glass panes 1710 Applying priming coat : 1711 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1712 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1713 Two or more coats on new work 1714 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1715 One or more coats on old work 1716 Miscellaneous 1717 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1718 Cement mortar 1:6 (1 cement : 6 coarse sand) 1719 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1720 Cement mortar 1:4 (1 cement :4 coarse sand 1721 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1722 ELECTRICAL WORK 1723 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1724 Group B 1725 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1726 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1727 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1728 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1729 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1730 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1731 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1732 Group B 1733 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1734 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1735 2 x 1.5 sq. mm 1736 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1737 25 mm 1738 32 mm 1739 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1740 100 mm X 100 mm X 60 mm deep 1741 150 mm X 75 mm X 60 mm deep 1742 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1743 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1744 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1745 S/F light plug point Modular type accessories :- 1746 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1747 S/F power plug point modular type accessories :- 1748 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1749 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1750 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1751 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1752 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1753 6 way, Double door 1754 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1755 4 way (4 + 12), Double door 1756 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1757 Single pole 1758 Single pole and neutral 1759 Triple pole 1760 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1761 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1762 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1763 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1764 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1765 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1766 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1767 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1768 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1769 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1770 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1771 Type-I Staff Qtrs. (12 nos. i.e. 3 block of 4 units each ) G 1772 Structural Repair & Retrofitting 1773 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1774 25 mm average thickness 1775 50 mm average thickness 1776 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1777 Bars upto 12 mm diameter 1778 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1779 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1780 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1781 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1782 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1783 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 1784 Repairs to Roof 1785 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick 1786 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1787 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1788 Repair to Toilets 1789 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1790 For thickness of tiles 10 mm to 25 mm 1791 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1792 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1793 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1794 75 to 80 mm dia pipe 1795 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1796 15 mm to 40 mm nominal bore 1797 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1798 Up to 150 mm diameter 1799 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1800 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1801 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1802 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1803 Up to 150 mm diameter 1804 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1805 Rectangular manhole 90x80 cm and 45 cm deep 1806 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1807 110 mm diameter 1808 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1809 a) Coupler 1810 110 mm 1811 b) Bend 87.5° 1812 110 mm bend 1813 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1814 75 mm diameter pipes 1815 100 mm diameter pipes 1816 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1817 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1818 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1819 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1820 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1821 Kitchen sink without drain board 1822 610x510 mm bowl depth 200 mm 1823 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1824 a) 32mm dia (for wash basin) 1825 b) 40mm dia (for sink and urinal) 1826 Providing & fixing CP brass Overhead shower with shower arm, Hand Shower 95mm dia Single Lever Concealed Deusch Mixer with Provision for Connection to Overhead Shower and Easy flex Tube with accessories complete I allrespect 1827 Providing and fixing of C. P. brass towel rail 600 x 20 mm size complete with C.P. brass brackets 1828 Providing and fixing of C. P. brass towel ring complete with C.P. brass brackets 1829 Providing and fixing CP Brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 1830 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1831 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1832 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1833 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1834 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1835 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1836 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1837 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1838 P-Trap type Floor Trap 110 x 75 mm 1839 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1840 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1841 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1842 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 1843 Providing & fixing soil, waste and vent pipes. 1844 a) 100mm dia centrifugally cast iron S & S pipe. 1845 b)75mm dia centrifugally cast iron S & S pipe. 1846 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1847 a) for 100mm dia pipe. 1848 b) for 75mm dia pipe. 1849 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1850 a) 100mm 1851 Sand cast iron S&S as per IS - 3989 1852 b) 75mm 1853 Sand cast iron S&S as per IS- 3989 1854 Providing and fixing plaincast iron S & S sanitary bend. 1855 a) 100mm 1856 Sand cast iron S&S as per IS - 1729 1857 b) 75mm 1858 Sand cast iron S&S as per IS - 3989 1859 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1860 a) 100x100x100mm 1861 b) 75x75x75mm 1862 Providing and fixingcast iron terminal guard. 1863 a) 100mm 1864 b) 75mm 1865 Providing & fixingcast iron coller. 1866 a)100 mm 1867 Sand cast iron S&S as per IS - 3989 1868 b)75mm dia. 1869 Sand cast iron S&S as per IS - 3989 1870 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1871 a) 100mm 1872 b) 75mm 1873 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1874 a) 100mm inlet & 75mm outlet. 1875 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1876 15 mm nominal outer dia Pipes 1877 20 mm nominal outer dia Pipes 1878 25 mm nominal outer dia Pipes 1879 32 mm nominal outer dia Pipes 1880 Providing and fixing brass stop cock of approved quality. 1881 15 mm nominal bore 1882 Providing and fixing gun metal gate valve with wheel of approved quality. 1883 a) 25mm dia nominal bore 1884 b) 32mm dia nominal bore 1885 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1886 a) 25mm. Nominal bore 1887 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1888 a) 15mm nominal bore 1889 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1890 a) 15mm nominal bore 1891 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1892 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1893 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1894 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1895 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1896 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1897 a) 15mm nominal bore 1898 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1899 a) 15mm nominal bore 1900 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1901 a) 15mm nominal bore 1902 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1903 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1904 25mm nominal bore, weighing not less than 62 gms 1905 Cutting holes up to 30x30 cm in walls including making good the same: 1906 With common burnt clay F.P.S. (non modular) bricks 1907 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1908 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1909 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1910 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1911 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1912 Repair to Plaster and Plinth Protection 1913 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1914 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1915 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1916 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1917 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1918 With cement mortar 1:4 (1cement: 4 coarse sand) 1919 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1920 15mm cement plaster on rough side of single or half brick wall of mix 1921 1:6 (1 cement : 6 course sand) 1922 6mm cement plaster to ceiling of mix : 1923 1:3 ( 1 cement : 3 fine sand) 1924 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1925 Raised and cut pointing 1926 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1927 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1928 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 1929 Old work (one or more coats) 1930 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1931 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1932 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1933 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1934 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1935 Repairs to Door / Windows 1936 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1937 Of area 3 sq. metres and below 1938 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1939 Of area 3 sq. metres and below 1940 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1941 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1942 Renewal of old putty of glass panes (length) 1943 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1944 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1945 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1946 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1947 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick. 1948 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1949 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 1950 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc, complete. 1951 300 mm weighing not less than 200gms. 1952 250 mm weighing not less than 150gms. 1953 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1954 100X58X1.90 mm 1955 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1956 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1957 300 x 10mm 1958 150 x 10mm 1959 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1960 125 mm 1961 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 1962 Twin rubber stopper 1963 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1964 30 mm thick shutterswith ISI marked M.S. butt hinges with necessary screws 1965 With ISI marked stainless steel butt hinges of required size 1966 Kiln seasoned and chemically treated hollock wood 1967 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1968 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1969 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1970 4.0 mm thick glass panes 1971 Applying priming coat : 1972 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. 1973 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1974 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1975 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 1976 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1977 One or more coats on old work 1978 Miscellaneous 1979 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1980 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 1981 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 1982 Edges of slabs and breaks in floors and walls 1983 Under 20 cm wide 1984 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 1985 Suspended floors, roofs, landings, balconies and access platform. 1986 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1987 Thermo-Mechanically Treated bars of grade Fe-500D or more. 1988 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1989 Cement mortar 1:6 (1 cement : 6 coarse sand) 1990 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1991 Cement mortar 1:4 (1 cement :4 coarse sand 1992 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1993 ELECTRICAL WORK 1994 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1995 Group B 1996 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1997 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1998 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1999 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 2000 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 2001 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 2002 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 2003 Group B 2004 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 2005 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2006 2 x 1.5 sq. mm 2007 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2008 25 mm 2009 32 mm 2010 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 2011 100 mm X 100 mm X 60 mm deep 2012 150 mm X 75 mm X 60 mm deep 2013 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2014 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 2015 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 2016 S/F light plug point Modular type accessories :- 2017 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 2018 S/F power plug point modular type accessories :- 2019 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 2020 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 2021 Supplying and fixing brass batten/ angle holder including connection etc. as required. 2022 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 2023 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2024 6 way, Double door 2025 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2026 4 way (4 + 12), Double door 2027 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2028 Single pole 2029 Single pole and neutral 2030 Triple pole 2031 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 2032 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 2033 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2034 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 2035 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 2036 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 2037 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 2038 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 2039 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 2040 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 2041 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 2042 WATER SUPPLY 2043 DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY 2044 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 2045 External work 2046 20 mm dia nominal bore 2047 25 mm dia nominal bore 2048 32 mm dia nominal bore 2049 40 mm dia nominal bore 2050 50 mm dia nominal bore 2051 65 mm dia nominal bore 2052 80 mm dia nominal bore 2053 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 2054 20 mm diameter pipe 2055 25 mm diameter pipe 2056 32 mm diameter pipe 2057 40 mm diameter pipe 2058 50 mm diameter pipe 2059 65 mm diameter pipe 2060 80 mm diameter pipe 2061 Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work. 2062 20mm dia nominal bore 2063 25mm dia nominal bore 2064 32mm dia nominal bore 2065 40mm dia nominal bore 2066 50 mm diameter pipe 2067 65 mm diameter pipe 2068 80 mm diameter pipe 2069 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 2070 50 mm dia 2071 80 mm dia 2072 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2073 20 mm nominal bore 2074 25 mm nominal bore 2075 32 mm nominal bore 2076 40 mm nominal bore 2077 50 mm nominal bore 2078 65 mm nominal bore 2079 80 mm nominal bore 2080 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 2081 Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work) 2082 25 mm nominal bore 2083 32 mm nominal bore 2084 40 mm nominal bore 2085 50 mm nominal bore 2086 65 mm nominal bore 2087 80 mm nominal bore 2088 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 2089 LD- 2.5 2090 Rectangular shape 600*450 mm internal dimensions 2091 Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 2092 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 2093 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 2094 with common burnt clay F.P.S.(non module) brick of class designation 7.5 2095 BOREWELL 380 MTR DEPTH 2096 Sub Head : I Tubewells 2097 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different trata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 2098 All Type of Soil 2099 400mm dia 2100 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 2101 All Type of Soil 2102 400mm dia 2103 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 2104 200 mm nominal size dia having minimum wall thickness5.40 mm 2105 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 2106 200 mm nominal size dia 2107 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- charge. 2108 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 2109 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 2110 200 mm dia 2111 Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 2112 200 mm clamp 2113 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 2114 200 mm nominal size dia 2115 Supply, installation testing & commissioning of borewell submersible pumping set suitable to operate on 415 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 200 mm outer dia uPVC Pipe as per IS : 12818with fittings, clamps etc. complete in all respect as per details given below : 2116 Pump Motor shall be Class F Insulation , Pump and Motor shall be IP : 68 Protection Rating , and Motor Efficiency shall be Class IE-3 Efficiency . 2117 Pump to be lowered below groundas site Boring/drilling 2118 Pump capacity : 15000 litres/hr 2119 Head : 250M 2120 H.P : 15 ( Approx) 2121 Totalof one set Tubewell 2122 Provding and fixing heavy duty 65mm G.I. pipe confiming to IS. 1239 upto 150 mm and IS 3589 for dia 200 mm and above with reducers, tees, flanges, elbow, crosses, union etc. and fixing the pipes onwall / ceiling / beam / floor including Clamping/Supporting the same, including painting with 2 coats of synthetic enamel paint as per the site requirement and shall be duly painted with two coats of approved quality synthetic enamel paint & shade over a readymix primer coat complete as required & as per directions of the engineer-in-charge for the following sizes: 2123 PANEL(Outdoor Type weather proof, double door with canopy and suitable MS Structure stand duly painted) 2124 INCOMER 2125 1 No.100 Amp FP MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 2126 Metering & Indication 2127 1 set of RYB phase indicating lamps 2128 MFM with Communication Facility along with control SP MCB 2129 Surge protection device , Type 2, MOV type for 8/20 us wave, 3 Nos phase to neutral, one No neutral to earth ,(minimum 3+1 mode) with minimum discharge capacity 40KA along with necessary fuses. 2130 BUS-BAR 2131 1 Set of 125A TPN Aluminium Bus Bar with colour coded PVC Sleeves 2132 OUTGOINGS 2133 3 Nos. 40A TPN MCB 2134 3 Nos. 25A DP MCB 2135 3 Nos. 20A DP MCB 2136 Plumbing Panel 2137 NOTE :- All starters shall have ON & OFF push button &suitable rating of contractor and overload relays 2138 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 2139 COST OF BORELOGING WORK (Bore logging is the process of recording detailed geological information from boreholes drilled during subsurface investigations. The primary aim is to understand the geological formations, stratigraphy, and hydrological conditions.) 2140 COST OF WATER QUALITY TEST ( Water quality testing involves analyzing water samples to determine their physical, chemical, and biological characteristics. )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
6.
Housing Urban and Rular Development #9417335 Technical Bid
Tender For Hdd Works For Iocl Green Belt Crossing At Paradip (Part A); 1 METALLIC MATERIALS AND CORROSION 2 Magnetic Cleaning and Electronic Geometry Pigging 3 Mobilisation/ Demobilisation of pigging tools, tackles, consumables, accessories and personnel by Contractor at work site including but not limited to magnet pigs, electronic geometry pigs and pig tracking device, temporary launcher and receiver as per Specification and other provision of the bid document including supply of material, equipment, manpower, etc. as required for geometry inspection and magnet cleaning in accordance with the EIL Specification B302-000-06-41-EGP-0011:A) MobilisationB) DemobilisationNOTE: Lumpsum charge is applicable for Mobilization and Demobilization charge only, and not for the entire Magnetic Cleaning and EGP charge. 4 Magnetic Cleaning:Running of adequate no. of Magnet Pigs for pipeline including pig tracking for each segment, preparation of site report as per Specification and provisions of the bid document. 5 Electronic Geometry Pigging:Running of adequate no. of Electronic Geometry Pig (Caliper) including pig tracking for each segment, preparation of site report on pipeline, data analysis at Contractors facility as per Specification and provisions of the bid document. 6 Defect Verification:Defect verification at a max. of 3 locations for each segment inspected including supply of all tools, tackles, instruments, personnel and their transportation, all earth work, repair of pipeline coating wherever exposed, backfilling, work complete in all respect as per direction of engineer-in-charge.NOTE: Unit EACH signifies each segment of the pipeline. 7 Final Report:Preparation of final work report as per agreed format and submission to Client / Clients Consultant in total of 4 copies. 8 CATHODIC PROTECTION 9 Cathodic Protection for HDD: 10 Survey, design, engineering, supply, installation, testing and commissioning of cathodic protection system for the HDD portion of the pipeline as per the enclosed specification vide document no.: B302-000-06-45-CSW-9523. All work shall be carried out conforming to the scope of work, design basis, data sheets, specifications, standards, drawings, etc as per the provisions of GCC, SCC and all materials, equipment, consumables, start-up/ commissioning spares etc. which include transportation, storage of materials at site, manpower, in line with direction of Engineer-in-charge. 11 INSTRUMENTATION 12 TELECOMMUNICATION WORKS 13 OPTICAL FIBRE CABLE INSTALLATION 14 Submission of OFC alignment sheets, as-built drawings and all documentation in accordance with the specifications. 15 Supply & installation of OFC distance markers (metal plates on pipeline markers) at all pipeline marker locations as per specifications and direction of CLIENT/CONSULTANT. 16 Supply of Jointing closures, Factory acceptance testing, storage, and transportation to site, loading, unloading, jointing of OFC all complete as per specifications provided in the bid document and direction of CLIENT/CONSULTANT. 17 Site acceptance Testing of the laid OFC, all complete as per specification and direction of CLIENT/CONSULTANT. 18 Supply of following Optical Fibre Cables (OFC) including FAT, storage, transportation to site, loading, unloading etc. all complete 19 24 fibres, single mode, compliant to ITU-T G.652 , Optical Fibre Cable 20 Supply of Permanently lubricated HDPE conduit for following sizes in required length of pressure rating 6 kgf/cm2 to be laid in pipeline trench or in separate trench directly or inside CS conduit including FAT, storage, transportation to site, loading, unloading etc. all complete 21 Duct with nominal diameter 40 mm or less 22 Laying, Testing and commissioning of the following sizes of HDPE duct/pipe of pressure rating 6 kgf/cm2, including supply of clamps, small iron structures, spacers, and duct accessories like push-fit couplers, bends and elbows, end plugs, simple plugs, sonic heads, etc, and including small civil works, cleaning with compressed air, calibrating, testing for air tightness, sealing of ends, including all labour and materials, as per directions of the Engineer-in-Charge. 23 Duct with nominal diameter 40 mm or less 24 Supply and Installation of Jointing pit/ blowing pit, sand, OFC joint identification markers, electronic markers etc. including jointing of OFC (with OFC laid by other contractor at both ends of HDD) in jointing pits, back filling, pulling wire for OFC/Duct Pulling (rugged and durable) etc. all complete 25 Installation and Laying of OFC through permanently lubricated HDPE conduit (which is sub-ducted in CS conduit) including supply and use of all materials required like couplers, end plug etc. all complete as per the job specification (Supply & Installation of CS Conduit are covered in the Pipeline laying Section of the tender) 26 PIPELINES 27 Site preparatory works for approach to Rig Placement area and String Preparation:All works required for the approach to the rig placement area and string preparation for the smooth execution of HDD includes formation of a temporary approach road, involving leveling, compaction, and required materials; Required quantity of Soil filling/ floating method or any other suitable method for crossing the nala / waterlogged areas/ ponds for placing the HDD rig and preparation of pipe string at designated area; Demolition of the boundary wall, including removal and disposal of debris; Restoration of the boundary wall after work completion, including necessary materials and labor; Removal of plants/trees, including uprooting and disposal; Plantation of additional trees as per instructions from the Engineer-in-Charge; Restoration of the site to its original condition post-completion, involving cleaning, leveling, and necessary repairs; and obtaining the No Objection Certificate (NOC) from the landowner. All works should be executed as per the instructions of the Engineer-in-Charge, ensuring the site is returned to its original condition after the completion of tasks. All works shall be carried in compliance with SOW doc. B302-000-83-44-SOW-9523 & its annexure. 28 INSTALLATION OF PIPELINE BY TRENCHLESS TECHNIQUE (USING HORIZONTAL DIRECTIONAL DRILLING) 29 Complete work for all type of crossings (RIVER/CANAL/ DRAIN/ NALA/ ROAD/ RAILWAY/ UTILITY) (between the limits as indicated in the drawing/ Scope of work) in all types of soil/ strata (including Normal Strata/ Hard Strata/ Hard Rock, as defined subsequently) including all additional drilled lengths necessitated by Contractors design and based on site conditions, carrying out geo-technical investigation, carrying out topographical and hydrological survey and collection of data to establish the bed of the water body (for River/ Unlined waterbody); calculation of scour depth of water body crossings (for River/ Unlined Waterbody), including construction design calculation andengineering of the crossing for all types of crossings, Receiving and taking-over, handling, loading, transportation and unloading of externally corrosion coated/ bare line pipes (as applicable) from designated place(s) of issue/ dump site(s) to Contractors own stock-yard(s)/ work site; mobilization and de- mobilization at site(s), supply of all materials as perScopeofSupply all consumables, equipment, manpower, other resources, temporary acquisition of additional land as required for string preparations/ all other works, andexecutionof,but notlimitedto, the followingworksinaccordancewithspecifications, drawings; preparationofallnecessaryconstruction drawings for Owners approval,Preparation of detailed construction method statement, calculations and installation procedures, Strings preparation including welding, NDT of welds and re-beveled areas, radiography,weldrepairandre-test,pre-hydro testing of completed string, corrosion coatingof fieldjoints withHDD sleeves, inspection of corrosion coating and repair of defects, installation of pipeline string by Horizontal directional drilling, Supply & Installation of 168.3mm size, 6.4 mm thk., API 5L Gr. B/ IS 3589 Fe 410 CSconduit for OFC (including 500µm of epoxy coating on CS Conduit as required) below thelowest level of the crossing including cover byseparate horizontaldirectional drilling to thecorrectprofileas per approved drawings and specification, Post-installationhydrotest including leaks and repair of defectsand retesting, etc. for defects attributed to Contractors faulty work, safe disposal of corrosion Inhibited water and bentonite, Supply, fabrication and construction of protective fencing as required; supply, fabrication and erection of pipeline markers; Restoration and clean-up etc., Preparation of as-built drawings and other records etc. All other works not specifically listed herein, but required as per drawings, scope of work, specifications, standards and provision of contract document, calculations, and instruction of Engineer-in- Charge, leading to successful completion of works. Notes: 1. Length of HDD shall be measured as actual curvilinear length between tie-ins at entry and exit.2. Payment shall be made on pro rata basis for any Increase/ decrease in HDD length. 30 Scope of Work Installation of Pipeline (Line Pipe Free issue from Owner) Pipe Material Grade API 5L Gr. X-70 PSL 2 Pipe OD 660 mmType of Crossing Any Other Type of Soil/Strata Normal Strata (Soft Soil/ Sand/ Clay/ Silty Sand/ Silty Clay etc.) Crossing Name Crossing-1 Chainage of Crossing 3.098 kmPipe Wall Thickness 15.9 mm 31 Scope of Work Installation of Pipeline (Line Pipe Free issue from Owner) Pipe Material Grade API 5L Gr. X-70 PSL 2 Pipe OD 660 mmType of Crossing Any Other Type of Soil/Strata Normal Strata (Soft Soil/ Sand/ Clay/ Silty Sand/ Silty Clay etc.) Crossing Name Crossing-2 Chainage of Crossing 3.829 kmPipe Wall Thickness 15.9 mm 32 PERMANENT MARKERS 33 Supply, fabrication and installation of following types of permanent markers along the route including allassociated civil works such as excavation in all types of soil, construction of pedestals and grouting withconcrete, clearing, supply and application of approved color & text and quality of primer and paint, stencil letter cutting for numbers, direction, chainage etc., restoration of area to original condition and performing all works as per drawings, scope of work, specifications, standards and instructions of Engineer-in-Charge. Note: The painting of all markers shall conform to environments specified as per scope of work and protective coating specification. 34 Type of Marker Pipeline Warning Marker 35 FABRICATION OF LR BENDS 36 Transportation of Company supplied free issue or Contractor procured bare line pipes to fabrication shop, fabrication of long radius bends, testing and transportation to worksite(s)/workshop(s) including loading, unloading and handling as per Scope of work and other provisions of the Contract as per the following details 37 Pipe OD 660 mmAngle of Bend 76 to 90 °Radius of Bend R=6D Pipe Material API 5L Gr. X-70 PSL 2 Wall thickness of Mother Pipe 15.9 mm 38 Pipe OD 660 mmAngle of Bend 61 to 75 °Radius of Bend R=6D Pipe Material API 5L Gr. X-70 PSL 2 Wall thickness of Mother Pipe 15.9 mm 39 LEAKS/ BURSTS (ATTRIBUTABLE TO OWNER) 40 Repair of Leaks/ Bursts in PipelineAll works for locating any major leak/burst (occurred during hydrostatic testing) or any minor leak by sectionalizing or any other methods which cannot be located by visual means, including necessary repairing/ replacing defective pipe length, including cutting and removing out defective pipes, transportation, pretesting of replacement pipe and welding into mainline, NDT of welds and re-beveled area, repair and re-testing of defective welds, coating/ painting of welded joints, clean-up, retesting the pipeline/ pipe segment including providing all necessary equipment, labour, materials, consumables and inputs other than Owner supplied materials and performing all works as per drawings, scope of work, specifications, standards enclosed with the Contract and directions of Engineer-in-Charge. Note: 1. This rate is applicable for manufacturing defects in Company/ Owner supplied material only. 41 Type of Leak Major Leak (detected by visual method) Pipe OD 660 mm 42 IDLE TIME PRESERVATION WORKS 43 Idle time preservation of Pipeline and Associated facilities: Preservation of complete pipeline and associated facilities and its maintenance by filling and pressurizing with nitrogen including supply and maintenance of nitrogen or by filling and pressurizing with corrosion inhibited water including supply and maintenance of water with regular dosing of inhibitor to maintain the effectiveness of the inhibitor water (along with disposal of corrosion inhibited water at a proper/ suitable location, after due preservation works) and supply of all consumables, all equipment, man- power, etc., complete as per the requirements of specifications, scope of work, standards, other provisions of Contract document and instructions of Engineer-in- Charge as per following details: 44 Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod 3 to 6 Month 45 Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod 6 to 9 Month 46 Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod 9 to 12 Month 47 Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod Up to 3 Month 48 Type of Preservation By Filling Nitrogen Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod 3 to 6 Month 49 Type of Preservation By Filling Nitrogen Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod 6 to 9 Month 50 Type of Preservation By Filling Nitrogen Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod 9 to 12 Month 51 Type of Preservation By Filling Nitrogen Pressure (Bar(g)) 2.0 Pipe OD 660 mmPeriod Up to 3 Month 52 PRE-COMMISSIONING AND COMMISSIONING ASSISTANCE FOR PIPELINES 53 Carrying out pre-commissioning activities and pre-commissioning checks to the specified acceptance criteria, making the entire pipeline system including stations ready for commissioning, providing assistance during the complete duration of commissioning operations, supply of all equipment, man-power, consumables, including all type of pigs and required quantity of nitrogen (if & as required), materials for all temporary works and performing all associated works, complete as per the relevant specifications, scope of work, standards, other provisions of Contract document and instructions of Engineer-in-Charge 54 Pre-Commissioning Works as per details: Type of Activity Dewatering Pipe OD 660 mm 55 Pre-Commissioning Works as per details: Type of Activity Swabbing Pipe OD 660 mm 56 Commissioning Assistance : All works for Commissioning assistance as per details below: Pipe OD 660 mm 57 VIDEO FILM & PHOTOGRAPHY OF CONSTRUCTION ACTIVITIES 58 Preparation of high resolution video films using drones or equivalent equipment as required (for minim 1 hr.) with audio commentary and Industrial photography covering all aspects/activities of pipeline construction annotated as required, conversion of same to video DVD/ Blue Ray/ USB Drive format, submitting three (3) sets of the same as per details in scope of work document.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 10
7.
Tourism #8648630 AOC
Integrated Development Of Craft Center At Sambalpur- 1 Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in all kinds of soil including moorum, hard stony earth, earth mixed with boulders etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. 2 Additional cost for Extra lift or 1.5m or part there of over the initial lift of 1.5m in all kinds of embankments and road works and ordinary earth work in general. 3 Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. 4 Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. 5 Providing & laying cement concrete of prop. (1:3:6) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge. 6 R.C.C. work ofM-25 for foundation having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. 7 R.C.C. work ofM-25 for plinth beam having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. 8 R.C.C. work ofM-25 for beam & column having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. 9 Ground Floor 10 R.C.C. work ofM-25 for lintel having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. 11 Ground Floor 12 R.C.C. work ofM-25 for roof slab having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. 13 Ground Floor 14 R.C.C. work ofM-25 for slope roof having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills. 15 Ground Floor 16 Providing & fixing TOR Fe-500 D grade reinforcement bars of approved makes as per DTCN for RCC work of required diameter with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the drawing, design and direction ofEngineer-in-charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) 17 Ground Floor 18 Brick work in foundation and plinth with flyash bricks in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. 19 Brick work in superstructure with flyash bricks in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. 20 Ground Floor 21 Brick work in superstructure with flyash bricks in cement mortar (1:4) with best quality bricks having crushing strength not less than 75 Kg/cm2 imersing the bricks in water for not less than 6 hours before use (the bricks shall be well burnt, free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge. 22 Ground Floor 23 Providing vitrified tile flooring using double charged vitrified tiles of premium grade having thick of 8mm to 10mm conforming to IS 13756 of 600mmx600mm coloured /printed series (homogeneous) of approved quality, colour in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. 24 Ground Floor 25 Supplying, fitting and fixing of double charged vitrified tiles in skirting of premium grade having thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm coloured /printed series (homogeneous) of approved quality, colour of approved quality and size in dadoes in all floors at all heights and riser of steps on 12mmm thick cement plaster (1:3) using screened and washed sharp sand for mortar with grouted Epoxy grout to match the shade of the tiles including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, curing-sundries and T&P, etc. required for the work complete as per specification and direction of Engineer-in-charge. 26 Ground Floor 27 Providingtile flooringexterior gradevitrified tiles of premium grade 10mm thick conforming to IS 4457 of 300mmx300mm of approved quality, colour in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. 28 Ground Floor 29 Providing 40cmx40cm sizespecial plain/printed series matt finish ceramic floor tiles of premium grade of approved make having thickness 7mm to 8mm, conforming to IS 13755 for ceramic tileflooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient, grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the ceramic tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as directed by the Engineer-in-charge. 30 Ground Floor 31 Providing 30cmx60cm size special plain/printed seriesedge cut ceramic wall tiles of premium grade of approved make having thickness 6.5mm to 6.7mm conforming to IS 13753 of approved make & shade in Dadoes over 12mm thick cement plaster 1:3 (1 Cement: 3 Coarse sand) finished with modular pointing in white cement & pigment to match the shade of the tiles including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour curing sundries and T & P etc. required for the work etc. complete as per specification and direction of Engineer-in-charge. 32 Ground Floor 33 Providing 20mm thick and above 0.40 Sqm size granite stone flooring in staircase of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect as per specification and direction of Engineer-in-charge. 34 Ground Floor 35 Providing and fixing in position well dressed, naturally seasoned sal wood rebated frames of size 125mmx63mm to doors including two coats of hot bitumen applied to rear of frame in contact with masonry or concrete surface fixed with MS hold fast of 35x5mm embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete with all materials, labours, T & P including cost, conveyance, loading, sundries required for the work etc. complete in all respect as directed by the Engineer-in-charge 36 Supplying fitting and fixing in position 32mm thick flush door with teak wood beading and 1mm thick sunmica to both side pasted with adhessive including fixing of fixtures like Godrej make Mortice lock having model no 9168, Godrej make Door closure having model no 8340, 100mm aluminium hinges, handle, tower bolt, stopper including cost of all materials, labour, all taxes, transportation, loading & unloading etc. complete as per specification and direction of Engineer -in-charge. 37 Providing and fixing in position WPC frames of following approved size to doorsfixed with MS hold fast of 35x5mm embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete with all materials, labours, T & P including cost, conveyance, loading, sundries required for the work etc. complete in all respect as directed by the Engineer-in-charge. 75mm x 50 mm 38 Providing and fixing in position 28mm thick WPC shutters of approved size to WPC door frames with hinges, handles, tower bolt etc complete with all materials, labours, T & P including cost, conveyance, loading, sundries required for the work etc. complete in all respect as directed by the Engineer-in-charge 39 Providing and fixing lockable openable system Aluminum works for openable doors applications. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Tex guard coating, silicon coated to suit marine atmosphere. All profiles should be Non insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major accessories should also be made by the same manufacturer. All panels will have no visible hinge or connecting hardware and shall not be connected on any side of the outer frame. The outer frame Depth will be 72mm. All materials which are used should be corrosion-resistant so that they are good functioning in different environments and that there are no negative influences either on the aluminium or on the surface treatment. Glass to be used is 6mm – 8mm toughened, make Saint Gobain. The system should allow the application of glazing or panels with thickness up to 5-8mm. System should have a 10-year warranty on properties, functionality and design, within restrictions defined by technical specifications of anodizing & 1year warranty on wearing parts 40 Providing and fixing Anodized System Aluminum three track Sliding glazed windows of TOSTEM / SHUECO/ ALUMIL make suitable for 2.4 KPA windload with 50mm visible aluminium section width in the centre interlock. The system offered must be ride-in system with two glass panels moving inside the channel without any external overhung along with a provision for mesh panel on the third track. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Texguard coating. Corner connection will be Butt joint with using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacturer. All Slider doors & windows will be centre locking with integrated Anti-lift in slider panel. Only EPDM gaskets should be used in all meeting points instead of Brush Pile. The outer frame Depth will be 104 mm +/- 3 mm The bottom frame must use a subframe and no direct grouting will be permitted on bottom frame directly. All glasses will be 5- 6 mm clear toughened.The system should allow glass thickness up to 10 mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. 41 Providing and fixing Anodized System Aluminum fixed windows of TOSTEM / SHUECO/ ALUMIL make, suitable for 2.4 KPA wind load. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Tex guard coating. Corner connection will be Butt joint with using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacturer. Only EPDM gaskets should be used in all meeting points instead of Brush Pile. The outer frame Depth will be 72 mm +/- 3 mm. All glasses will be 6 - 8 MM toughened depending on grid size. Beyond 6000 mm width, MS section (size 61 x 122 mm) coupling to be used with cover profiles of same anodized colour. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. 42 Providing and fixing Anodized System Aluminum glass louvers of TOSTEM / SHUECO/ ALUMIL make natural air flow ventilators. The extruded aluminium sections shall be made from Grade 6063- T5 Anodized with Tex guard coating. All other major Accessories should also be made by the same manufacturer. Only EPDM gaskets should be used in all meeting points instead of Brush Pile. The outer frame Depth will be 50 - 72 mm. System should have a 10-year warranty on properties, functionality and design, within restrictions defined by technical specifications of anodizing & 1-year warranty on wearing parts. 43 Supplying, fitting and fixing of M.S window grills ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damagedwalls/ structures with cement concrete (1:2:4)with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge. 44 Supplying, fitting and fixing of M.S grill gates with top and bottom rails (as per I.S. specification and as per approved drawings) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damagedwalls/ structures with cement concrete (1:2:4)with black hard crusher broken granite stone chips of 12mm to 20mm size (20mm size not to exceeds 25%) including watering and curing etc. complete in all respect as directed by the Engineer in charge. 45 Supplying, Fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mmx32mmx2mm @ 0.90mtr C/Cand stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification buffing polishing etc with cost conveyance taxes of all materials labour T&P etc required for the complete in all respect. 46 Providing & fixing of Greenlam Sturdo Essentia Collection- Serene Restroom Cubicle (of following standard dimension which includes 600mm door size width) self-supporting 12mm thick compact laminates made out of, urea free, thermosetting phenolic resins treated Kraft papers as core material and Amino plastic resin treated decor papers on the finish surface, conforming to latest and applicable IS: 2046-1995, EN 438:2016 and NEMA LD3-2005 quality standards with Antivirus, Antibacterial and Antifungal properties (conforming to ISO 21702:2019, JIS Z2801:2010 and ASTM G21-2015 standards respectively) to fulfil the applicable requirements of indoor air quality certifications for Greenguard-Gold standards. This also includes providing and fixing in position necessary hardware made out of Nylon Polyamide grade 6 & Aluminium alloy grade 6063-T6 powder coated finish in black and other available color hardwares as per manufacturers specifications & Architects instructions like (1) Self closing hinges in Nylon Polyamide grade 6 in gloss finish in available colors (2) Soft closing thumb turn lock made in nylon polyamide grade 6 in gloss finish in available colors (3) Single Coat hook in nylon polyamide grade 6 in gloss finish, available in similar available colors (4) U & F- profiles in Aluminium alloy grade 6063-T6 with powder coating in available colors (5) Nylon polyamide grade 6 Adjustable Leg (6) Top rail along with Nylon Polyamide grade 6 with end cap is a Round D shaped extrusion made of Aluminium alloy grade 6063-T6 with Powder Coating in available colors, (7) Rubber, (8) Screws & wall Plugs (SS316). The top fitting should consist of Matt finish aluminium alloy grade 6063-T6 in avilable colors, which will get fixed on pilasters with SS Screws, All screws will of 316 Grade in stainless steel. All pilasters are supported by grade- 6 Nylorn Polyamide Thermoplastic palm design pedestal footing with non corrosive steel inserts. The base anchored to the floor with grade 316 satin finish stainless steel screws with push fit capping at a clearance height of 150mm. Toilet Cubicle Partitions with standard dimensions of 1995mm Height x 1000mm Width x 1500mm Depth (which includes 600mm door width) 47 Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to inside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. 48 Ground Floor 49 Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. 50 Ground Floor 51 Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, taxes of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. 52 Ground Floor 53 Finishing wall surface with Acrylic wall putty to inside surface of approved make and finished smooth and even surface to receive painting to inside surface including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc complete as per direction of Engineer-in-charge. 54 Ground Floor 55 Finishing wall surface with Acrylic wall putty to outside surface of approved make and finished smooth and even surface to receive painting to inside surface including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc complete as per direction of Engineer-in-charge. 56 Ground Floor 57 Providing and painting two coats with plastic emulsion paint over a coat of primer of approved quality and approved shade in all floors at all height by making the surface to the interior plastered surface of wallsmooth including cost, coveyance, loading and unloading and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. 58 Ground Floor 59 Painting to external surface of building with two coats of weather coat over a coat of primer of approved shade and quality of approved design, after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance and taxes of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. 60 Ground Floor 61 Providing and painting two coats with synthetic enamel paint over a coat of red oxide primer of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height including sand papering and making the surface smooth with cost, coveyance, loading and unloading, and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. 62 Ground Floor 63 Providing 25mm thick grading concrete in C.C. (1:2:2) laid in proper slope over terrace roof slab by using two part of sand, one part of cement and two parts of6mm size black hard crusher broken granite chips with addition of water proofing compound of approved quality to be mixed with specified ratio including watering, curing, cost, conveyance, royalties, taxes of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. 64 Ground Floor 65 Providing 20mm. average thick grading plaster with cement mortar of mix (1:4) in all floors at all height with portland slag cement on top of roof slab after chipping and chiseling the same and cleaning the entire surface with wire brush, finished smooth to proper slope and gradient with watering and curing etc. complete including cost, coveyannce, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. 66 Ground Floor 67 Providing and applying 2 coats of 1mm thick elastomeric cementitious waterproofing coating Brushbond RFX of Fosroc Chemicals Tested to ASTM D4060, ASTM D4541, ASTM D638, ASTM C836. with Adhesion to concrete : >1N/mm2for waterproofing structures like roof slabs, sunken slabs, chajjas, tunnels, water tank etc. after proper surface preparation and soaking the surface with water prior to application complete as specified and directed by the Department at all levels. 68 Providing kota stone flooring using Rajasthan kota stone of approved quality, colour and size of 25mm minimum thick in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the kota stone with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the kota stone, if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect as per specification and direction of Engineer-in-charge. 69 25 mm. average thick artificial stone flooring with cement punning laid to proper slope with cement concrete of proportion (1:2:4) using screened and washed sharp sand for mortar with black hard crusher broken granite stone chips of approved quality and from approved quarry, washed and cleaned laid in two layers i.e. the bottom layer being 19 mm . thick and top layer of 6mm. thick with 12mm. to 20. size black hard crusher brokenstone chips (20mm size chips not to exceed 25%) including chipping and chiseling and cleaning the top surface of the floor slabs in upper floors, including rounding of corners, watering and curing with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge 70 Providing and injecting chemical emulsion for pre - constructional antitermite treatment as per IS specification and creating a chemical barrier in bottom and sides of foundation trenches, top-surface of plinth filing junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and cables etc. complete using approved quality of chemical emulsion of requisite quantity prescribed by the manufacturer as directed by the Engineer-in-charge including cost of all materials and labour taxes etc. complete. (indemnity bond for warranty for 5 years to be furnished) 71 Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge. 72 Rolling & compacting to sub grade or formation loosening by cutting earth for 15cm below the sub grade including watering and compacting in layers by PRR, cost & conveyance of required quantity of water, cost of all labour sundries, T & P etc. required for the work to complete in all respect as per specification and direction of Engineer-in-charge. 73 Construction of granular sub-base by providing Close graded Granular subbase Grading-IV material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (5th Revision) etc complete as per direction of Engineer-in-charge. 74 Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works 75 Supplying and laying of M40 grade heavy duty factory made hydraulically pressed and mechine vibrated free cast interlocking pavers of 80mm thick, coral shaped preparation of sub base with 50mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-chrge. 76 Providing and laying at or near ground level factory made kerb stone of M-30 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 77 Providing and painting two coats with synthetic enamel paint over a coat of cement primer of approved quality and approved shade confirmming to ISI on cement work to give an even shade in all floors at all height including sand papering and making the surface smooth with cost, coveyance, loading and unloading, and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. 78 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. 79 Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. 80 Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge 81 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001 82 Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm 83 Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm 84 Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). 85 Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge. 86 Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge. 87 Plastic Waste bin Rectangular alongwith fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 350x350 mm Top Dia.250x250 mm Bottom Dia.850 mm Height pair Sintex, Nilkamal, Otto, Aristo 88 Plastic Waste bin without Wheel with Push type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level capacity 60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo 89 Plastic Waste bin without Wheel with Swing lid type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity-60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo 90 Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of land manure before and after flooding trench with water (excluding the cost of imported earth, sludge or manure). 91 Supplying and stacking of good earth at site (Earth measured in stacks will be reduced by 20% for payment) with all lead and lift. 92 Supplying and stacking sludge at site (sludge measured in stacks will be reduced by 8% for payment) with all lead and lift. 93 Supplying and stacking at site dump manure fromdumping place nearest to site of work.(manure in stack will be reduced by 8% for payment) with all lead and lift. 94 Screened through sieve of I.S designation 20 mm. 95 Screened through sieve of I.S designation 16 mm. 96 Screened through sieve of I.S designation 4.75 mm. 97 Rough dressing the trenched ground including breaking clods. 98 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of up rooted vegetation with all lead and lift. 99 Fine dressing the trenched ground. 100 Spreading of sludge, dump manure or land good earth in required thickness. (Cost of sludge, dump manure or/and good earth to be paid separately). 101 Mixing earth and sludge or manure in proportion specified or directed. 102 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 103 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 104 Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (The manure/sludge shall be paid for separately). 105 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 106 Holes 60 cm dia, and 60 cm deep 107 Holes 45 cm dia, and 45 cm deep 108 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 109 Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge.Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm 110 Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid separately.) Size of Empty Pots 35cm Top dia, 25cm Bottom Dia & 35cm Perpendicular height. 111 Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. 112 Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. 113 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) 114 Trees Plant 115 Shrubs Plant 116 Hedge Plant 117 Providing and displaying of Aglaonema dove variety Plant, having ht. 30 cm to 45 cm with 8 to 10 leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. 118 Providing and displaying of Aglaonema Snow-White hybrid plant (three in one), having ht. 30 cm & above with 6 to 8 leaves, bright colour, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot . (Specimen Plant) & as per direction of the officer-in-charge. 119 Providing and displaying of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. 120 Providing and displaying of Croton Challanger variety plant, having ht. 30cm and above, well developed with full of fresh and healthy leaves in 20 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. 121 Providing and displaying of Croton Baby Golden plant (three in one), having ht. 30cm, multi branches, well developed with fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer-incharge. 122 Providing and displaying of Dracaena Song of India plant (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. 123 Providing and displaying of Money Plant Broad Leaves mounted on moss stick 90 cm ht., 3 to 4 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot . & as per direction of the officer-in-charge. 124 Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. 125 Providing and Displaying plants Cladium Hybrid variety 3 to 4 plants in a pot well developed with fresh & healthy foliage 30 to 45 cm ht. in different colour 25 cm Earthen Pot/Plastic Pot and as per direction of the officer incharge. 126 Providing and Displaying plants Cosmos well developed fresh & healthy 20 to 25 cm ht. attractive colours multi branching at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. 127 Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. 128 Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. 129 Providing and Displaying Acalypha green plant well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot bushy plant as per direction of the officer-in-charge. 130 Providing and Displaying Bamboo Buddha vally variety with umbrella shape plant having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy plant as per direction of the officer-in-charge. 131 Providing and Displaying Fishtail palm plant well developed with fresh & healthy foliage leaves of ht 210 to 240cm Specimen plant in 35 cm Cement Pot as per direction of the officer-in-charge. 132 Providing and Displaying Foxtail palm plant well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge. 133 Supply and stacking of Acacia auriculiformis plant of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 134 Supply and stacking of Adansonia digitata (kalp vricksh) plantof ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 135 Supply and stacking of Azadirachta indica ( Neem ) plant of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 136 Supply and stacking of Bottle palm plant of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags. 137 Supply and stacking of Casuarina equisetifolia plant of height 150-165 cm in big poly bags of size 25 cm as per direction of the officer-in-charge. 138 Supply and stacking of Ficus nuda plant of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 139 Supply and stacking of Nauclea cadamba (Kadam) plant of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.v 140 Supply and stacking of plant Bauhinia acuminata height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. 141 Supply and stacking of plant Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 142 Supply and stacking of plant Hibiscus rosasinensis of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge. 143 Supply and stacking of plant Nerium oleander (kaner) dwarf of height 30-40 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge. 144 Supply and stacking of plant Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. 145 Supply and stacking of Jasminum humile (Yellow) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 146 Providing and fixing overhead type sprinkler system with self closing valve type 25mm X 20mm with self closing springmade up ofalluminium alloy and brass fittings including cost of all materials, labour, T & P etc complete as per direction of Engineer-in-charge. 147 Supplying all materials, labour, T&P and fixing 15mm dia CPBib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. Make: Jaquar/Grohe/Johnson/Roca 148 Supplying all materials, labours, T&P and fitting and fixing of the 20mm dia CPVC pipeconfirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. (Concealed) 149 TOTAL FOR CIVIL WORKS-(A) 150 PH WORKS 151 Supplying all materials, labours, T&P for fitting and fixing white glazed vitreous china floor mounted European water closet of Hindware make having cat no 20087 or equivalent type of approved make including supply of matching P/S trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete including cost of WC pan, PVC seat cover with CP brass hinges and rubber buffers etc all complete including cost, taxes and conveyance as per specification including polishing etc all complete as per PH specification and direction of Engineer-in-charge. 152 Supplying all materials, labours, T&P for fitting and fixing white glazed vitreous china wall mounted European water closet of Hindware make having cat no 20098 or equivalent type of approved make including supply of matching P/S trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete including cost of WC pan, PVC seat cover with CP brass hinges and rubber buffers etc all complete including cost, taxes and conveyance as per specification including polishing etc all complete as per PH specification and direction of Engineer-in-charge. 153 Supply all materials, labour,T&P for fitting and fixing of Pneumatic tank 3/6L with full frame andPneumatic faceplate in polished chrome of Jaquar make having cat no 517444 and 525732 or equivalent type of approved make complete with all parts and internal fittings of approved make with ISI mark and supplying of necessary brackets, screws etc 32mm dia flush bend, connecting pipe with CP or brass union nuts at each end as per PH specification all complete as per direction of Engineer-in-charge. 154 Supply all materials, labour,T&P for fitting and fixing of dual flush PVC cistern of hindware sleek essence make or equivalent type of approved make complete with all parts and internal fittings of approved make with ISI mark and supplying of necessary brackets, screws etc 32mm dia flush bend, 15mm dia 450mm long PVC water connecting pipe of jaquar make having cat no ALD 803AB with CP or brass union nuts at each end as per PH specification all complete as per direction of Engineer-in-charge. 155 Supplying all material, labour T&P and fixtures for providing and fixing of white glazed vitreous chinaware counter top wash hand basin of size 49cm dia of Hindware make having cat no 10052 or equivalent type of approved make with bottle trap of Jaquar cat no ALD 769L250x190 with CP waste coupling nut of Jaquar make having cat no ALD 709 and 15mm x 450mm PVC connection pipe of Jaquar make having cat no ALD 803AB with MS bracket with wooden plugs CP screws including cost of cement, sand, labour, T&P etc. complete including testing cost, conveyance, royalty and taxes of all materials etc. complete as per PH specification and direction of Engineer-in-charge. 156 Supplying and fixing urinal of hindware make having cat no 60022/60023 or equivalent type of approved make including all fittings like 450mm long connection pipe of Jaquar make having cat no ALD 803B, waste pipe etc of approved make etc complete as per PH specification and direction of the Engineer-in-charge. 157 Supplying and fixing 12mm thick toughened glazed urinal division plate of approved size with etching and polishing including concrete grouting and edge moulding etc complete as per PH specification and direction of the Engineer-in-charge. 158 Supplying all materials, labor T&P for fitting and fixing in all floors fixed type glass mirror of size 600mm x 450mm best INDIAN make of 5.5 mm thickness with supply of 13mm thick asbestos backing and wooden plugs C. P. Brass screw including cost, conveyance, royalty, taxes of all materials complete as per P.H. specification and direction of Engineering-in-charge. 159 Supplying all materials, labour, T&P and fixing standard sized15mm dia Concealed Stop cock of Jaquar Cat. No.-FLR 5083NK or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 160 Supplying all materials, labour, T&P and fixing standard sized15mm dia Angular Stop cock of Jaquar Cat. No.-FLR 5053N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 161 Supplying all materials, labour, T&P and fixing standard sized15mm dia pillar cock of Jaquar Cat. No.-FLR 5015 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 162 Supplying all materials, labour, T&P and fixing two way Bib cock of Jaquar Cat. No.-FLR 5041N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 163 Supplying all materials, labour, T&P and fixing health faucet of Jaquar Cat. No.-ALD 573 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 164 Supplying all materials, labour, T&P and fixing standard sizedCP towel ring square of Jaquar Cat. No.-ACN-1121N or equivalent etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 165 Providing and fixing C.P. Glass shelf 600mm long of Jaquar Cat. No.-ACN-1171N or equivalent type of approved make fixed to wall including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 166 Supplying all materials, labour, T&P and fixing standard sizedCP Soap case of Jaquar Cat. No.-ACN-1131N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 167 Supplying all materials, labour, T&P and fixing standard sized liquid soap dispenser of Jaquar Cat. No.-ACN 1135N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 168 Supplying all materials, labour, T&P and fixing standard sizedCP toilet paper holder of Jaquar cat. No.-ACN1153S or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 169 Supplying all materials, labour, T&P and fixing standard sizedCP robe hook of Jaquar Cat. No.-ACN 1191N or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 170 Providing all materials, labour,T&P and fittings and fixing of flush valve of Jaquar Cat. No.-PRS 073 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 171 Providing and fixing 6L step can in stainless steel of Kohler make having cat no K-17531T-ST etc complete as per PH specification and direction of the engineer in charge 172 Providing and fixing fragrance disperser of Euronics make having cat no EA44 etc complete as per PH specification and direction of the engineer in charge 173 Providing and fixingcircular type stainless steel grating with hole for floor /nahani trap etc complete as per PH specification and direction of the engineer in charge 174 Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipe SDR11 confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. (Concealed) 175 15 mm dia 176 20 mm dia 177 25 mm dia 178 32 mm dia 179 Supplying all materials, labours, T&P and fitting and fixing of the following size of UPVC pipe S-80confirming to IS 13592 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance of all materials all complete as per PH specification and direction of Engineer-in-charge.(Non Concealed) 180 40mm dia 181 50mm dia 182 Supplying all materials, labour, T&P, fitting and fixing UPVC SWR pipes & fittings of approved make confirming to IS-13592, both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:2:4) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge. 183 75mm dia 184 110mm dia 185 Supplying all materials, labour, T&P, fitting and fixing of UPVC SWR fittings of approved make with requisite testing etc complete as per PH specification and direction of Engineer-in-charge. 186 110mm dia Single Junction with door 187 110mm dia Double Junction with door 188 110mm dia Cowl 189 110mm dia Plain Bend 190 110mm dia SWR Door Bend 191 125mm x 110mm Gulley Trap 192 110mm dia Tee with door 193 110mm dia Single Junction without door 194 110mm dia Socket Plug 195 110mm dia Pipe clip 196 110mm diaCoupler 197 75mm dia Plain Bend 198 Supplying all materials, labour, T&P, fitting & fixing of different size UPVC Ball Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and direction of the Engineer-in-charge. 199 25mm Dia 200 32mm Dia 201 40mm Dia 202 50mm Dia 203 Providing & fixing of 50mm dia UPVC body non return valve of approved make with high tensile bress rising stem suitable for the system pressure as per IS specification. 204 Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. 205 Supplying all materials,labours,T&P for cutting holes through existing RCC floors & roofs including making good the damages for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. 206 Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking SWR/HCI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. 207 Supplying all materials,labours,T&P for cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per direction of Engineer-in-charge. 208 Supplying all materials, labour, T&P and fittings and fixing of 1000 LTR Poly Propelene white double layer water storage Tank of approved make confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc including hoisting upto terrace level and placing the tank to the required position etc all complete as per PH specification and direction of Engineer-in-charge. (To provided with brick masonary guard walls which will be paid separately) 209 Supplyng all materials, labour, T&P for construction of brick masonary Gulley trap chamber of size 250mm x 250 mm with CI gulley trap, by flyash brick masonry in CM (1:4), CP (1:3) with 150mm x 150mm CI grating including labour and materials for fitting and fixing 100mm dia square mouth CI gully trap with supply of all jointing materials and encasing the gully trap with a block of CC (1:3:6) with 25mm size hard stone metal all complete with providing and fixing of 250mm x 250mm precast RCC cover slab including cost, conveyance, taxes of all materials to site complete as per the PH specification and direction of Engineer-in-charge. 210 Supplying all materials, labour, T&P, fitting and fixing UPVC SWR pipes & fittings of approved make confirming to IS-13592, both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:2:4) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge. 211 150mm dia 212 200mm dia 213 Supplying all materials, labour, T&P and necessary materials towards laying of RCC NP2 Hume pipe push tight joint type (including cost of RCC Hume pipe) inside the pipeline trench of required size with plastic rope without damage to the pipe with all convenience the materials to site and including all taxes all complete as per direction of Engineer-in-charge. 214 150mm Dia 215 200mm Dia 216 Supplying all materials,labours,T&P for constructing inspection chamber of 900mmx800mmx450mm with cement concrete (1:3:6) on bed with hard granite metal size 40mm and flyash brickwork in cement mortar (1:4) in foundation and plinth, 100mm thick RCC M25 cover slab with supplying fitting and fixing of medium duty SFRC manhole cover, moulding and shaping the channel and benching with cement concrete (1:2:4) using 12mm size hg chips,12mm thick cement plaster in cement mortar (1:3) with punning to inside, cement plaster in CM (1:3) to outside the chamber including centring, shuttering, providing required quantity of MS rods and binding wires for reinforcement, bending, binding, tying the grills and placing in the proper position and drawing and design and PH specification including cost, conveyance, royalty, taxes etc for all materials as per the drawing, design and direction of Engineer-in-charge. 217 Construction of circular brick masonary manhole chamber of size 1.20 x 0.90 mtr including cement concrete (1:3:6) in bed by using 40mm size granite metal, brickwork in CM (1:4) in foundation & plinth, cement plastering (1:3) over flyash brick, plastering in CM (1:3) with neat cement punning, CC (1:2:4) over bed for benching and channeling, RCC M25 for roof slab of 150mm thick and supply fitting and fixing SFRC medium duty type cover including cost of centring and shuttering cost of MS rod for RCC work, supplying fitting and fixing of the polypropelen step iron of required interval etc all complete with all cost, conveyance, royalties taxes etc all complete as per direction of Engineer-in-charge. 218 Extra for every additional depth of 0.10mtr or part there of manhole size 1200x900mm from 1100mm to 1650mm depth (data for 0.10 mtr per each) 219 Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in all kinds of soil including moorum, hard stony earth, earth mixed with boulders etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. 220 Extra lift or 1.5m or part there of over the initial lift of 1.5m in all kinds of embankments and road works and ordinary earth work in general. 221 Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. 222 Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of bedding for pvc pipes of the following internal diameter including curing complete as per specification (A1-Type Bedding) 223 150mm Dia 224 200mm Dia 225 Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge. 226 Supplying and filling the pipeline trench with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. 227 Supplying and construction of 100 user septic tank of standard size as per drawing, design and direction of Engineer in charge. 228 Supplying all materials,labours,T&P and constructing 1.22m dia and 2.1m depth soakway pit with precast RCC rings joined loose,gravel backing in the rear of well steining,precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty etc all complete as per approved specification and direction of Engineer-in-charge. 229 Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: 230 Rocky terrain with boulder formation for 300m depth 231 Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well). 232 Supplying 200mm polyvinyl chloride pipes as per ASTM-D-1785-89 schedule 80 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and internal threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes,pipes shall be provided with a groove at the male thread to accomodate flexible PVC/Rubber O ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. 233 Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. 234 Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) 235 Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge 236 Supplying all materials, labours, T&P, fitting and jointing of 80mm dia double flanzed column GI pipe confirming to IS 1239/1968, medium class having IS mark of approved make / tata medium series with socket and screw joint including supply, fitting and fixing of required number of IS certified fitting, cutting threads to pipe and pipes to length including wastage providing necessary offsets and lay screw with extra socket and jam nut including fixing to wall and floors with supply of holder bats, clamps, fixing wooden plugs in walls complete as per direction of Engineer-in-charge. 237 Supply, installation, testing and commisioning of vertical submerssible pump set of approved make having discharge 30m3 per hour and 70mtr head including installation of pump set withwire ropes, clamps etc inside the borewell, etc complete as per the Direction of Engineer-in-charge. (Duty of pump to be decided depending upon yeild of the borewell) 238 Supply, installation, testing and commisioning of automatic star delta control panel suitable for 10HP pumpset including MS box fitted with main switch ,contactor, single phasing preventer, timer, selector switch, voltmetre, ammeter etc and connection with motor inside the borewell complete as per the Direction of Engineer-in-charge. (Excluding power supply and flat cable for connection with motor) 239 Protection to the Borewell with CC base 240 3 core 6.0sqmm copper flat cable 241 Bore Cap 242 Clamp 243 Supplying all materials, labours, T&P and fitting and fixing of the following size of UPVC pipe (Sch-80)confirming to ASTM D1785 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance of all materials all complete as per PH specification and direction of Engineer-in-charge.(Non Concealed) 244 80mm Dia 245 65mm Dia 246 Supplying all materials, labour, T&P, fitting & fixing of different size UPVC Ball Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance of all materials, T&P etc. all complete as per P.H. specification and direction of the Engineer-in-charge. 247 65mm Dia 248 80mm Dia 249 Providing & fixing of following dia UPVC body non return valve of approved make with high tensile bress rising stem suitable for the system pressure as per IS specification. 250 65mm Dia 251 80mm Dia 252 Supplying all materials & labour, T&P and constructing brick masonary chamber for water sluice valve, single air valve & non return valve with flyash brick masonary in cement mortar (1:4) as per approved drawing and specification CC (1:4:8) with 4cm size hard granite metal on the bed, 12mm cement plaster (1:3) to inside and cement flush pointing (1:3) to outside surface with 100mm thick RCC M25 cover slab with 12mm hg chips using required quantity of tor steel, centring and shuttering to the slab and dismantling it after 31 days of casting, filling the outside cavity with excavated materials, watering, curing including cost, conveyance, taxes of all materials, labour charges for cutting, bending, binding and tying the grills in proper position etc all complete as per drawing, design and direction of Engineer-in-charge. 253 Sluice Valve Chamber (0.75x0.75x1.20mtr) 254 Supplying all materials, labour, T&P, fitting & fixing of different size bourden type pressure gauge of reputed make (0-10 kg/sqcm) with valves, piping, fitting of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and as per the direction of the Engineer-in-charge. 255 Supplying all materials, labour, T&P and fitting and fixing of double air valve confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge. 256 INTERNAL ELECTRIFICATION WORK 257 TRAININING ROOM AND SKILL DEVELOPMENT CENTER 258 Wiring 259 Wiring to light points/fan point/exhaust fan point/Call bell point with 1.5-sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non metalic PVC flexible condute with 6Amp, 250V Modular Switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ KEI) 260 Primery point 261 Secondary point 262 Call bell point 263 Wall bracket fan/Air circulator point specification same as above. 264 Exhaust fan point specification same as above. 265 Ceiling fan point consisting of modular regulator of Legrand make model name Myrius or equivalent on existing switch board 266 Supply and fixing of 6Amp plug with 6amp switch on existing board (Modular type ISI marked) 267 Point wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular type switch, phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required. (convinient power) (Make of wire-Finolex/ L&T/ Anchor/ Havells/ KEI) 268 Supply and fixing of ISI marked modular type 2nos 6Amp plug with switch on suitable size of metal box and modular cover in fronton surface or recess including all conection. 269 Supply and fixing of ISI marked modular type 1nos 6Amp plug with switch and 1nos 16Amp plug with switch on suitable size of metal box and modular cover in fronton surface or recess including all conection. 270 Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp plug with switch with all conection. 271 Supply& fixing of Modular type 25 Amp one way switch and socket outlet for AC point with metal box and modular cover. 272 Recessed/surface extra lead submain wiring alongwith earth wire with the folowing size of PVC insulated single core multistrand coper conductor of ISI marked conforming to IS 694/1990 in 20mm dia non metalic heavy duty flexible condute 1.6mm in surface/recessed PVC condute as required (Make of wire-Finolex/ L&T/ Anchor/ Havells/ Great White/ KEI) exceeding to Long point in 2x1.5sqmm + 1x1.5sqmm. 273 Submains: 274 Recessed/surface submain wiring alongwith earth wire with the following size of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in required dia non metalic heavy duty flexible condute 1.6mm in surface/recessed PVC condute as required. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ Great White/ KEI) 275 2 x 2.5 sq.mm. + 1 x 1.5 sq.mm. 276 2 x 4.0 sq.mm. + 1 x 1.5 sq.mm. 277 2 x 6.0 sq.mm. + 1 x 2.5 sq.mm. 278 4 x 4.0 sq.mm. + 2 x 2.5 sq.mm. 279 4 x 6.0 sq.mm. + 2 x 2.5 sq.mm. 280 4 x 10.0 sq.mm. + 2 x 4.0 sq.mm. 281 CONTROL PANELS : 282 Supply, delivery, installation, testing & commissioning of L.T. Indoor floor / wall mounted typeDistribution Board made out of 2 mm thick CR sheet metal cubiclewith front side hinges glass door for every meter compartment, the cabinet have a common bus bar, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade; dust, damp & vermin proof powder coated; having hinged door and compartmental arrangement for eachequipment& busbar chamber onthe top of the panel; having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-Charge.All MCCB shall confirm to IEC- 60947 and IS-13947. MCCB shall comply with the isolation function requirement of IEC-60947-2 section 7.1.2 to be marked as suitable for isolation / disconnection to facilitate safety of person in use. All MCCB have Ics=100% Icu and the overload setting should be from 0.7 to 1 times of Ir for thermal magnetic release and for microprocessor release the overload Settings: 0.4 to 1 times of Ir. Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) . The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. 283 MAIN PANEL (TRAININING ROOM AND SKILL DEVELOPMENT CENTER). Incoming - (MCCB: 1 No 250A (36kA) 4P thermal magnetic(TM) release with ROM & spreader links. SPD: 1No 50kA 4P T1+T2. MCB C: 1 No 63A 10kA 4P.CHANGE OVER SWITCH: 1 no 250A 4P On Load Change OverSwitch.); Outgoing -(Busbar: 2 SET, 4Nos 320 Amp Copper Strips. (CD=1.6A/sqmm). MCCB: 4 Nos 100A (16kA) 4P thermal magnetic(TM) with ROM & spreader links for DB Training Room & Skill Development Center, DB Community Hall, OAT & Spare. MCCB: 5 No 63A (16kA) 4P thermal magnetic(TM) with ROM & spreader links for Pump Room, STP DB, External Light Feeder Panel, Solar Input & Spare.); Instruments - (1 Set of LED type RYB phase indicating lamps with control fuses & 1no multi function meter with required CTs) 284 DB TRAININING ROOM AND SKILL DEVELOPMENT CENTER (TRAININING ROOM AND SKILL DEVELOPMENT CENTER).Incoming- MCCB: 1 No 80A (16kA) 4P thermal magnetic(TM) release with ROM & spreader links. CHANGE OVER SWITCH: 1 no 100A 4P On Load Change OverSwitch); Outgoing - [Busbar: 2 SET, 4Nos 100 Amp Copper Strips. (CD=1.6A/sqmm). MCB C 3 Nos 40/63A 10kA 4P for 4 Way TPN BDB for Power & Spare. MCB C 3 Nos 32A 10kA 4P for 4 Way TPN BDB for Light & Spare. MCB C 3 Nos 40A 10kA 2P for SPN BDB/ SPARE]. Instruments - (1 Set of LED type RYB phase indicating lamps with control fuses & 1no multi function meter with required CTs) 285 Distribution Board COMMUNITY HALL:Incoming - (MCCB: 1 No 80A (16kA) 4P thermal magnetic(TM) release with ROM & spreader links. CHANGE OVER SWITCH: 1 no 80A 4P On Load Change OverSwitch); outgoing - [Busbar: 2 SET, 4Nos 100 Amp Copper Strips. (CD=1.6A/sqmm). MCB C 3 Nos 40/63A 10kA 4P for 4 Way TPN BDB for Power & Spare. MCB C 3 Nos 32A 10kA 4P for 4 Way TPN BDB for Light & Spare. MCB C 3 Nos 40A 10kA 2P for SPN BDB/ SPARE]; Instruments- (1 Set of LED type RYB phase indicating lamps with control fuses & 1no multi function meter with required CTs) 286 Distribution Board OAT:Incoming - (MCCB: 1 No 80A (16kA) 4P thermal magnetic(TM) release with ROM & spreader links. CHANGE OVER SWITCH: 1 no 80A 4P On Load Change OverSwitch); Outgoing -[ Busbar: 2 SET, 4Nos 100 Amp Copper Strips. (CD=1.6A/sqmm). MCB C 2 Nos 40/63A 10kA 4P for 4 Way TPN BDB for Power & Spare. MCB C 2 Nos 32A 10kA 4P for 4 Way TPN BDB for Light & Spare. MCB C 2 Nos 40A 10kA 2P for SPN BDB/ SPARE. MCB C 8 Nos 32A 10kA 2P for Power Cercuit/SPN BDB/ SPARE]; Instruments- (1 Set of LED type RYB phase indicating lamps with control fuses & 1no multi function meter with required CTs) 287 Supply, delivery, installation, testing & commissioning of L.T. indoor floor/ wall mounted type distribution boards made out of reputed company IP 43 - #IK 09 with metal door having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. 288 4way TPN BDB for Light: Incoming - (1 no of 25A 30mA 4P RCCB); Outgoing-(12 nos of 6-16A SP MCB C) 289 4way TPN BDB for Raw Power: incoming - (1 no of 63A 4P MCI); Outgoing - (12 nos of 10-32A SP MCB) 290 12 way SPN BDB: incoming- (1 no of MCB C 32A (10kA) 2P); Outgoing- (10 nos of 6-10A SP MCB C. Cable Laying) 291 Supply, laying & testing of following size of PVC insulated, PVC sheathed, round armoured aluminium conductor power cable of 1100 volt grade laid on surface of wall / column / existing RCC / stone ware / masonry cable trench / cable trey / through G.I. pipe / hume pipe as the case may be, including cost of saddles / clamps / markers etc but excluding the cost of G. I. pipe / hume pipe complete with making good the damages caused and returning the balance unused cables to stores as required and as per direction of Engineer-in-charge. 292 4 core x 240 sqmm A2XFY 293 4 core x 25 sqmm A2XFY 294 Cable termination: 295 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required complete as per the direction of Engineer-in-charge. 296 4 core x 240 sqmm A2XFY 297 4 core x 25 sqmm A2XFY 298 Earthing 299 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and as per the direction of Engineer in charge. 300 Providing and fixing of 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 301 Providing and fixing 4.00 mm dia hard drawn bare copper wire on surface or in recess for loop earthing as required. 302 Fittings & Fixtures 303 Supply,installation, testing & commissioning of following types of light fixtures directly on wall / ceiling of building with allaccessories such as drivers, lamps cover etc complete assembly including supply of all accessories and making connection from the suitable point outlet complete as per the direction of Engineer-in-charge. 304 22 watt LED extruded aluminium batten for continuous operation and available in 4ft run length, suitable for surface, wall & conduit mounting (with accessories) similar to make ‘Signify’ Cat no. BN021C LED22S complete. 305 12 watt LED extruded aluminium batten available in 2ft run length with multiple lumen packages and suitable for surface, wall & conduit mounting (with accessories) similar to make ‘Signify’ Cat no. BN 021 LED12S 6500 complete. 306 Inverter type 9 watt LED Bulb on existing holder of approved make 307 12 watt LED, Brightest metal surface light with 100lm/W light output, Full low diffusor allows for wider light spread of 270 degrees, Aluminum die cast housing for better heat dissipation, Longer life of 30,000 hours^, Super slim design with a height of just 38mm allowing the product toblend seamlessly with the ceiling, Surge protection of 3kV with wide voltage protection of 160-360V similar to make Philips model name Metal FullGlow complete. 308 65-70 watt Highbay LED efficacy of 150Lm/W with its robust housing design and cater to diverse applications with multiple options of beam angles and suitable for surface mounting (with accessories) similar to make ‘Philips’ Cat no. BY515P LED100S 5700 complete. 309 36 watt SmartGlow is an intelligent office lighting recessed luminaire with built in PIR occupancy sensor offering flexibility of auto switching off when the space is not occupied similar to make Signify Cat no.RC383B P LED 36S complete. 310 5 watt recessed mounted down light, Decorative finish downlighter with hallmark silver ring for beautiful aesthetics, Ultra thin trim for a seamless fit, High lumen efficiency, Aluminum housing for better performance, Designed for robustness: wide voltage protection from 160V-360V, Surge protection up to 2.5kV similar to make Philips model Aura StylEdge complete. 311 7 watt recessed mounted down light, Decorative finish downlighter with hallmark silver ring for beautiful aesthetics, Ultra thin trim for a seamless fit, High lumen efficiency, Aluminum housing for better performance, Designed for robustness: wide voltage protection from 160V-360V, Surge protection up to 2.5kV similar to make Philips model Aura StylEdge complete. 312 10 watt LEDTrack light, Long-lasting fixture, Robust metal construction, Functional, minimal design, Perfect fit for any home/outlet, Wide voltage protection from 160V–360V and surge protection up to 2KV, Premium white aluminium housing,No harmful UV radiation similar to make Philips Stanchion Track Light model no.31445 complete. 313 Track fo installation of track light similar to make Philips Stanchion Track model no 31442 complete. 314 48-50 watt LED Suspended 50mm aluminium extruded linear lighting luminaires with superior white powder coated finish (with accessories) similar to make ‘Philips’ Cat no. SP780P LED52S-6500 complete. 315 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, Ceiling Fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. Canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required similar to make Crompton Cat no. Energion HS - 5 Star BEE complete. 316 Supply, delivery, installation, testing & commissioning of single phase 400mm sweep wall mount fan similar to make Crompton Cat no. WM Hiflo Wave Plus complete. 317 Supply, delivery, installation, testing & commissioning of wall mounted air circulator 750mm sweep (Crompton make model nameAC750WALL / Havells/ Bajaj) 318 Supply, delivery, installation, testing & commissioning of single phase 600mm sweep 900 RPM heavy duty Exhaust fan(Crompton make cat no EXHD600-6-1/ Havells/ Bajaj) 319 Supply, installation, testing & commissioning of metal Exhaust Fan 300mm sweep similar to make ‘Crompton’cat no Trans Air 12 complete. 320 Supply, delivery, installation, testing & commissioning of plastic Ventilation fan 150mm sweep similar to make Crompton cat no Brisk Air Neo 6 complete. 321 Supplying and fixing Call bell Buzzer suitable for single phase, 230 volts, 1 Module of similar to make Legrand Myrius Cat no. 6792 50 complete. 322 Supply and fixing circular / hexagonal G.I. box for ceiling fan hook, of internal dia 140 mm, 75 mm height, top lid of 1.5 mm thick G.I. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the G.I.box by means of 3.3 mm dia round headed screws, one lock at the corners. Hook shall be made of 10 mm dia galvanised M.S. bar bent to shape as per standard drawing. 323 Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required. (more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.) 324 Testing, commissioning and charging of entire wiring system for TRAININING ROOM AND SKILL DEVELOPMENT CENTER. 325 Testing, commissioning and charging of entire wiring system for COMMUNITY HALL. 326 Testing, commissioning and charging of entire wiring system for OAT GREEN ROOM. 327 EXTERNAL ELECTRIFICATION (100kVA SUB-STATION) WORK 328 CABLING WORK 329 Supply of following size of PVC Armoured cables ISI marked. 330 4 core x 150 sqmm A2XFY 331 Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. 332 4 core x 150 sqmm A2XFY 333 Cable Trench & Hume Pipe 334 Construction of cable trench of size [1000mm(W) x 1000mm(D)] complete , base foundation with C.C 1:3:6, 250mm brick walls,filling the inside area with sand, removableRCC slab for chambers with C.C 1:2:4 on the top, wall and top plastering etc complete as per the approved drawing 335 Construction of cable trench of size [600mm(W) x 1000mm(D)] complete, base foundation with C.C 1:3:6, 250mm brick walls,filling the inside area with sand, removableRCC slab for chambers with C.C 1:2:4 on the top, wall and top plastering etc complete as per the approved drawing. 336 Supply, delivery and laying of floowing sizes of RCC Hume pipe at a depth of 1000mm Ground level for cable laying as required including cost of all accessories, jointing, masonry inspection chamber at both ends etc completeas per direction of Engineer-in-charge. 337 150mm dia RCC Hume pipe 338 250mm dia RCC Hume pipe 339 TRANSFORMER INSTALLATION WORK 340 Supply & fixing CT meter sheet steel enclosures made out of 16 gauge CRCA sheet ,double door with lock, neopraene gasket all around, two numbers earth lugs including painting ,padlock arrangement. Class 0.5 with O/P burden of 30VA 341 Supplying and erection of 150X 150 RS joist pole of 11m long. (30.6 kg /mtr). 342 Supply installation and commissioning of 200Amp 11kv on load isolated air brake switch with braking capacity of 10kA complete with following accessories. Knife blade switches both Male/Female. Operating GI pipe with handle & rotating mechanism. Pad locking arrangement with pad lock. Scope also includes interconnecting AB switch OH line with 30sqmm AAC conductor & interconnection to pin insulator/HG fuse set by suitable Cu flexible strip .Spring earth of the handle ,earthing of switch etc. 343 Supply installation and commissioning of 11kV home gap fuse set on the double pole structure. The 11KV HG fuse set to be complete with 11KV insulators Cu horn gaps etc. The scope also includes interconnecting the HG fuse with transformer with 0 SWG HDB Cu conductor. (11KV, 200Amp, 3Pole) 344 Supply installation and commissioning of 11KV lighting arrester including interconnection by 30sqmm AAC conductor & clamp(12KV, 5KA) 345 Supply and fixing of substation bracket inj complete set. With 100x50x6 mm for MS channel, 75x40x6mm MS channel for AB switch and HG fuse, 50x50x5mm MS angle for Transformer (140Kg) including painting. 346 Supply installation and commissioning of 11KV Disc Insulator 90 KN (B & S type) 347 Supply & fixing of11 KVDisc hard ware fittings (in pairs) 348 Supply installation and commissioning of HT Stay set with complete accesssories like Anchor rods, insulators, bow eye bolts and stay wires. Scope inclusive of supply of stay clamps. 349 Supply of materials and installation of pipe earth electrode made out of 40mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCCcover complete with labour for excavation of pitinall kinds of soil & rock as required and as per direction of Engineer-in-charge. 350 Supply of materials and installation of chemical earthing size of chemical earth bar 3 mtr, size of earth pit 3 X 2 X 9 chemical compound to be used 50 kg. There is an arrangements forterminationofcopper strip of earth continuity conductor including cost of water pouring arrangements, brick masonary enclosure on top with removable cast iron cover complete with labour for excavation of pitinall kinds of soil & rock as required and as per direction of Engineer-in-charge. 351 Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. 352 Supplying and laying 25 mm x 5mm G.I. strip on surface or in recess for connection etc as required. 353 Supply & fixing ofGInuts, bolts & washer of assoarted size for above work. 354 Supply installation and commissioning of 100 KVA, 11/0.4KV (AL) Transformer with tap changer, BIS Energy level-II with necessary hardware including unloading from truck, leading to the pole/plinth location and EMR test etc as required. 355 Supply & providing of 11K GI pin & pin insulators 356 Providing and binding with aluminium binding wire for all type binding for transformer installation work. 357 Supplying and painting with Aluminium Paint where ever required for transmission line. 358 Supplying and painting with Black paint where ever required for transmission line. 359 Supplying and painting with Redoxide paint where ever required for transmission line. 360 Supply installation and commissioning LT Distribution Panel Board for 100KVA Transformer with MCCB, Aluminium Busbar for two Bay with Kitkat Fuse. 361 Supply installation and commissioning LT Busing cover in the LT site of the transformer 362 Supply and construct with all material for Boundary wall for fencing and anti climbing with M.S. Gate 5-0 x 8-0.Sand & Gravel spreading over the entire area. 363 Supply and construct with all material for plinth of size 5-0x5-0x6-0. 364 11 KV Single Circuit line 365 Supplying and erection of 150X 150 RS joist pole of 11m long. (30.6 kg /mtr). 4 nos 366 Supply & fixing of(100 x 50 x 6)mm M.S Channel 367 Supply & fixing of11 KV V cross arm. 368 Supply & fixing of 11 KV top chanel.. 369 Supply & fixing of back clamp for cross arm 370 Supply & providing of 11K GI pin & pin insulators 371 Supply installation and commissioning of 11KV Disc Insulator 90 KN (B & S type) 372 Supply & fixing of11 KVDisc hard ware fittings (in pairs) 373 Supply installation and commissioning of HT Stay set with complete accesssories like Anchor rods, insulators, bow eye bolts and stay wires. Scope inclusive of supply of stay clamps. 374 Supply & installation of coil earthing 375 Supply & fixing ofassoarted nuts, bolts & washer for above work. 376 Providing and binding with aluminium binding wire for all type binding for transformer installation work. 377 Supply & stringing with 80mm² insulated AAA Conductor. 378 Supplying and painting with Aluminium Paint where ever required for transmission line. 379 Supplying and painting with Black paint where ever required for transmission line. 380 Supplying and painting with Redoxide paint where ever required for transmission line. 381 Garding 382 Supply & fixing of(75 x 40 x 6)mm M.S Channel 383 Supply & fixing of No 8 G.I wire 384 Supply & fixing ofeye hook 385 SAFETY EQUIPMENTS & OTHER: 386 Supply and hanging of Shock Treatment Chart duly Laminated. 387 Supply & Laying of 8 mm Thick Rubber Mat (1mtr x 2mtr), ISI mark of 1100 V Grade. 388 Supply and Installation of 4 Nos. Fire Buckets on a Mild Steel Stand complete as per specification and requirement of Fire Safety Provisions. 389 Supply and Installation of 4.5 Kgs. Capacity CO2 type Fire Extinguisher complete as required. 390 Providing and fixing bi-lingual Danger HT notice board of 250mmx200mm as specified below,made of mil;d steel at least 2mm thick & vitreous enamelled signal red color on both sides as background & with insprictions in enamelled vitreous white color on front side for lettering as required. 391 Supply of First Aid box with all required accessories. 392 EXTERNAL ILUMINATION 393 Feeder Panel with timer 394 Supply, delivery, installation, testing & commissioning of L.T. Indoor floor / wall mounted typeDistribution Board made out of 2 mm thick CR sheet metal cubiclewith front side hinges glass door for every meter compartment, the cabinet have a common bus bar, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade; dust, damp & vermin proof powder coated; having hinged door and compartmental arrangement for eachequipment& busbar chamber onthe top of the panel; having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-Charge. Incoming: 1 no 63A 4P MCCB (16 KA) type followed by 1 No 63-A 4 NO power contactor with Bypass Toggle switch & timer. Bus bars: 4 Nos.20x3mm E C Strips. Outgoing: 4 Nos 40/63-A, 4P MCB C (10kA). 4 nos 40/63 Amp 2P MCB C (10 KA).Complete duly factory wired as per SLD. Cable & wires 395 Junction Box 396 Supply, installation and testing ofCable Junction Boxes IP 66/67 “weather proof”, for outdoor installation with terminals, made of high quality Thermoplastic for cable size 10-16sqmm and box size 155mm x 210mm x 92mm (Hensel make or equivalent) 397 CABLES & ACCESSORIES 398 Supply, laying & testing of following size of PVC insulated, PVC sheathed, round armoured aluminium conductor power cable of 1100 volt grade laid on surface of wall / column / existing RCC / stone ware / masonry cable trench / cable trey / through G.I. pipe / hume pipe as the case may be, including cost of saddles / clamps / markers etc but excluding the cost of G. I. pipe / hume pipe complete with making good the damages caused and returning the balance unused cables to stores as required and as per direction of Engineer-in-charge. 399 3c x 2.5 Sq. mm flexible Copper cable for connection of lamp from JB 400 2c x 6 Sq. mm Aluminum armoured cable. 401 4c x 10 Sq. mm Aluminum armoured cable. 402 4c x 16 Sq. mm Aluminum armoured cable. 403 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 404 Supplying and fixing of following dia ISI marked HDPE pipe with material grade PE-80 in ground/recess including excavation the earthl and making good the same in case of recessed conduit as required. 405 40mm OD PN-8, 3 mm thick 406 90mm OD PN-4, 3.5 mm thick 407 110mm OD PN-4, 4.3 mm thick 408 Supply, delivery and laying of floowing sizes of RCC Hume pipe at a depth of 1000mm Ground level for cable laying as required including cost of all accessories, jointing, masonry inspection chamber at both ends etc completeas per direction of Engineer-in-charge. 409 150mm dia RCC Hume pipe 410 Fittings & Fixtures 411 Supply of 7meter long aesthetically designed QUADRA MAST light pole. Pole shall made up of Hot Dip Galvanized Body andcoated with zinc rich primer & pure polyester powder coatingand finished with jet black colour and 3 coat Marine grade. The pole shall be suitable for fitting of 4nos of 100W rectangular design street light made up ofExtruded aluminium body and Clear toughend glass diffuser. Dimension of light must be 607 x 200 x 230mm. Body size of the pole will □150mm from bottom and 100mm size from middle to top. The Pole shall have base Plate□300 x 16mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge.(Make: K -lite Pole KP-2042-700 + KL-4461 Luminaries/ equivalent ). 412 Supply of 3 meter long aesthetically designed decorative lighting pole with 400mm height Cast Aluminium base, cast aluminium ring on the middle portion. Pole shall be made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating of black with gold embellishment finish. Bottom dia of the pole will be Ø139.7mm, Middle portion dia will be Ø76.1 mm and having base Plate of size □200 x12mm thick with provision for founation bolt. Pole is Compatible for Ø70mm size for cable entry & exist. Junction Box service door is made up cast aluminium and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 32A 4pole terminal connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge. (Make: K -lite Florian Pole KP- 4329/ equivalent). 413 Supply of 50W LED Post Top Light made up of Die Cast Aluminium base with spun aluminium top cover Body with clear Acrylic diffuser and having Dimension : Ø400 x 807 protected with IP 65, Surge Protection : 6KV, THD : <10% (Make: K -lite Imperial KL- 5444/ equivalent). 414 Supply, delivery, installation and testing of 4000mm long 100mm dia quadra extruded aluminium alloy pole with LED 45 watt post top light and foundation bolt and all fixing acessories with required size of rcc foundation as per direction of Engineer-in-charge. (K-Lite Pole cat noKP-5052, K-Lite Fitting cat no KL-5436 or equivalent),Pole made of extruded aluminium alloy (grade 6063) can achieve high strength and corrosion resistance in various atmospheric conditions, Pole design parameters vary depending on the type of bracket and loading factor, All pole sections are welded using special v groove technique by certified welders using high end MIG welding processes, The control gear tray is prewired with MCB, terminal connectors for loop-in / loop-out arrangement.Built-in control box with service Can be Integrated with LED Modules. door including lock and safety chain (except 200 x 50).Earth connection. Safety class I, CE-Conformity mark,BIS - Conformity mark. 415 Supply, delivery, installation and testing of 8w LED Bollard 100mm dia 1000mm long for uniform illumination for pathways with required size of cc foundation as per direction of Engineer-in-charge. (K-Lite cat no KL-4823/ Ligman/ Simes/ Unilamp/ equivalent). Luminaire made of extruded aluminium alloy (grade 6063) with die-cast aluminium components and non corrosive SS fasteners. Reflector system made of die-cast / spun aluminium. Non yellowing UV stabilized polycarbonate clear / translucent diffuser, Silicone gasket.Cast Iron / aluminium mounting plate with an anchorage unit made out of hot dip galvanised steel for extra guarantee against corrosion. Luminaire can be aligned on the mounting plate around 360°. Cast Iron / aluminium mounting plate with an anchorage unit made out of hot dip galvanised steel for extra guarantee against corrosion. Luminaire can be aligned on the mounting plate around 360°. Cable entries for through-wiring of mains supply cable. Protection class IP54 / IP65. Integral power supply. Earth connection. Safety class I. CE-Conformity mark. BIS - Conformity mark. Suitable for operation on 240V, 50Hz single phase ac supply.
Contract Date: Jan 23, 2026 Contract Value : 6.76 Crore
Government Departments No of Bidders 11
8.
Housing Urban and Rular Development #8319809 AOC
Infrastructure Upgradation Of Veterinary Dispensary At Burla In Sambalpur District.- 1 Clearing & grubbing shrub, jungles including uprooting stumps of trees and trees below 1.0 m. girth and thick bushes including bamboo clamps based on pre-measurement disposing the debris away from the work site with all leads,lifts and delifts with cost of all labour,T & P, hiring and running charges of all machineries, cess complete as per direction of Engineer-in-Charge. 2 Earthwork in all kinds of soil for excavation of foundation with initial lead and lift including dressing and leveling the beds etc. completein all respects as per direction of the Engineer-in-Charge. 3 Dewatering of standing / ponding water by using 10HP diesel dewatering pumps of average depth of standing water0.5m depth and discharging the same outside the working area with cost of all labour, T&P, taxes, POL etc. complete as directed by the Engineer-in-Charge. 4 Supplying and filling the foundation & plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150cm thick watering & ramming including cost, conveyance, royalty and taxes of all materials, cost of all labours, T & P etc as required for the work complete as per direction of the Engineer-in-Charge. 5 Providing & laying plain cement concrete 1:3:6 (1 cement: 3 sand: 6 stone aggregate 20mm nominal size) as levelling course in foundation & plinth etc including tampering, curring, shuttering etc. complete all depth and height including cost, conveyance, royalty and taxes of all materials, cost of all labour, T & P etc as required for the work complete and as direction of Engineer-in-Charge. 6 Providing and laying Cement Concrete M20 using 20mm size down graded Black H.G. crusher brocken chips for R.C.C. works including cost, carraige, rayality of all materials and machinaries and labours with all leads, lifts etc completeas per approved drawings & specification & direction of the Engineer-in-charge. 7 Rigid and smooth centering and shuttering for R.C.C. works including false works and dismantling then after casting including cost of materials complete in R.C.C. footing, column, slab, stair case, landing, lintel including cost, conveyance, royalty and taxes of all materials, cost of all labour etc as required for the work complete and as direction of Engineer-in-Charge. 8 Footing, Plinth Beam 9 Roof Beams,column,girder and bressmer 10 Lintel 11 Roof slab & Chajja 12 Cutting, straightening colled or bent up M.S. rods, HYSD steel or Tor steel or grade Fe-415 confirming to I.S.-1786 - 1985 welding or jointing if necessary, bending, binding, tying the grills as required for RCC works, and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of m.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost). 13 Fly Ash brick masonary in Sub structure in cement mortar (1:6) in using Fly ash Bricks of 23cm x 11cm x 8 cm having crushing strength not less than 75 Kg/Cm2including watering, curing and cost, conveyance, royality of all materials & cost of labour charges etc complete. 14 Fly Ash brick masonary in Supper structure in cement mortar (1:6) in using Fly ash Bricks of 25cm x 12cm x 8 cm having crushing strength not less than 75 Kg/Cm2including watering, curing and cost, conveyance, royality of all materials & cost of labour charges etc complete. 15 6mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T & P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. 16 Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. 17 Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. 18 2.5cm thick grading concrete (1:2:2) on roof6mm c.b.h.g. chips 19 Providing and laying Vitrifiedtiles 600x600 mm. 1st quality laid on 25mm thick cement mortar 1:6 (1cement:6coarse sand) including pointing the joints with white cement and matching pigments, etc. complete design/drawings including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labourrequired for the works etc. complete in all respect as directed by the Engineer-in-Charge. 20 Providing and laying Anti-skid ceramic floor tiles 300x300 mm approved make conforming to IS:13755 1st quality laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete design/drawings including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labourrequired for the works etc. complete in all respect as directed by the Engineer-in-Charge. 21 Supplying, fitting & fixing of 30cm x 30cm/40cm x 40cm special plain/printed series Wall Ceramic tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 in dadoes, skirting and risers of steps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge 22 Finishing wall surface of walls with Acrylicwall putty (water based) ofapproved make and finished smooth and even surface to receive painting including cost of scafolding staging charges with cost of all materials, taxes, labour, T. & P. etccomplete. 23 Providing and applying to outside walls with two or more coats of -Fungal weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, and direction of Engineer-in-Charge at all elevations including all material labour complete. 24 One coats to wall with any approved primer of approved shade including cost, carriage, taxes of paints, brush, putty, scaffoldind charges, labour charges, cess etc. complete as per direction of Engineer-in-Charge. 25 Painting two coats with plastic emulsion paint over a coat of water as per the direction of Engineer-in-Charge at all floors and all heights including all material & labour complete. 26 Providing & painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the direction of Engineer-in-Charge at all floors and all heights including all material & labour complete. 27 Providing, fitting and fixing of aluminium door with aluminium door section of 9202 as vertical member 9201 as top member and 9200 as bottom and middle member and with 12mm thick glass fixed on door frame by means of tapered clip no. 4660 and the frame to be completed by means of jointing angle no. 1855 including all cost of labour and T & P hire charges of drilling mechine, labour charges etc. as per the direction of Engineer- In- Charge. 28 Supplying,fittting,fixing of window(Sliding Type) made of Aluminium section 9778 as window frame,section No 4095,4096 and 9777,3994 as shutter frame with 5 mm thick black glass as panel fitted with rubber bidding including locking arrangement, including all fitting ,including cost of materials, all taxes/labour,T&P etc complete as per direction of Engineer -in- Charge 29 Supplying,fitting and fixing general iron grill,door and window etc. complete with clamps including making good to the wall,ceiling and floor all complete as per specification (Local Market Rate) 30 Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge 31 Provide and apply 2 coats of acrylic based polymer modified water proofing coatingapproved brand and manufacture including cost, carriage, taxes of paints, brush, putty, scaffoldind charges, labour charges, cess etc. complete as per direction of Engineer-in-Charge. 32 APPROACH ROAD WORK 33 Earthwork in all kinds of soil for excavation of foundation with initial lead and lift including dressing and leveling the beds etc. completein all respects as per direction of the Engineer-in-Charge. 34 Supplying and filling the foundation & plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150cm thick watering & ramming including cost, conveyance, royalty and taxes of all materials, cost of all labours, T & P etc as required for the work complete as per direction of the Engineer-in-Charge. 35 Providing & laying plain cement concrete 1:3:6 (1 cement: 3 sand: 6 stone aggregate 20mm nominal size) as levelling course in foundation & plinth etc including tampering, curring, shuttering etc. complete all depth and height including cost, conveyance, royalty and taxes of all materials, cost of all labour, T & P etc as required for the work complete and as direction of Engineer-in-Charge. 36 Rigid and smooth centering and shuttering for R.C.C. works including false works and dismantling then after casting including cost of materials complete in R.C.C. footing, column, slab, stair case, landing, lintel including cost, conveyance, royalty and taxes of all materials, cost of all labour etc as required for the work complete and as direction of Engineer-in-Charge. 37 Providing and laying of Granular Sub-base course using coarse graded aggregate by providing the materials conforming to Grading-III of Table 400-1 complete as per Technical Specification Clause 401 of specifications for Road and Bridge works of Ministry of Road Transport & Highways (5th Revision) and as per the direction of the Engineer-in-charge. 38 Supplying and fixing of 60mm thick cement concrete interlockingpaver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018. 39 (B) Electrical Work 40 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sqmm FR copper conductor single core cable in surface/ recessed medium class PVC conduit with piano type switch , phenolic laminated sheet , suitable size MS box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. (make- HAVELLS /HPL / VGUARD/ FINOLEX/ ANCHOR) 41 GROUP A 42 GROUP B 43 GROUP C 44 Recessedwiring to 5A /6Amp socket outlet with 2 X 1.5sq.mm FR PVCinsulated single core multistrand copper conductor of ISI marked in recess 20mm dia non metallic PVC flexible conduit with piano type switch, Phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 X 1.5sq.mm FR PVC insulated single core multistrand copper conductor forloop earthing etc. as required (Make of wire -Finolex/ L&T/ Anchor/ Havells/V-Guard/Great White/HPL) Separate 45 Separate 46 Supply and fixing of 5Amp plugwith switch on existing board (Piano type)1.25.1+1.25.2 47 Supply and fixing ofmetal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing of 6pin 5/6 & 15/16Amp socket outlet and15/16Amp piano type switches connection painting etc. as required. (make-Anchor/ Cona/Great white/HPL) 48 Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire -Finolex/L&T/Havells/V-Guard/Great White/Mescab/HPL/KEI) 49 2 X 1.5sq.mm +1 X 1.5sqmm 50 2 X 2.5sq.mm +1 X 1.5sqmm 51 2 X 4sq.mm +1 X 1.5sqmm. 52 2 X 6sq.mm +1 X 2.5sqmm. 53 4X6sq.mm+2X2.5sq.mm 54 INVERTER WIRING with 1.5sqmm PVC S/C multistrand Copper wire 55 Supply and fixing of superior type call bell of ISI marked, on 6 X4conforming to IS-2268/1994 and bell push of ISI marked , conforming to IS-1293/1988 (make-Cona/Anchor/Benlo) 56 (Ding Dong) call bell . 57 S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose . 58 Supplying and fixing of stepped type electronic fan regulator on the existing switch box including connections but excluding laminated sheet etc.asrequired. 59 Supply and fixing of Computer Board having 5amp 3 nos Switch & Socket 60 Supply and fixing of 63Amp DP main Switch (Make-Hager/ scheinder / Siemens ) 61 Zero maintenance chemical earthing 6FT 62 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 63 SPN 8 way (8+12) IP 30 (MAKE Legrand model EKINOX3 ETPN DB CATNO. 507601 or its equivalent ) 64 TPN 4 way (8+12) IP 30 (MAKE Legrand model EKINOX3 ETPN DB CATNO. 507660 or its equivalent ) 65 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 66 C Curve SP MCB 240/410V 6-32A (MAKE Legrand model DX3 MCB or its equivalent to Hager/ scheinder / Siemens ) 67 C Curve DP MCB 415V 6-32A (MAKE Legrand model DX3 MCB or its equivalent to Hager/ scheinder / Siemens ) 68 C Curve FP MCB 415V 6-32A (MAKE Legrand model DX3 MCB or its equivalent to Hager/ scheinder / Siemens ) 69 Supply & installation of Panel Board wall mounted size 18 X 13 X 6 made out of 16 SWG CR sheet with powder coating & with following arrangement. -1) 63Amp 4P 16Ka MCCB-1no (Legrand/ Snider)(3) 63A cu B/B -1nowith digital instruments with voltmeter,transparent glass, amperemetre, CT coil, Selector switch, Panel fuse & RYB indicator. 70 Supply and fixing ofA.C Ceiling fan 48 size. (Make-Polycab -Vital / Crompton -Jura/ Havells-Velocity/ Usha-striker/Orient-new breezee/Summer Cool , Polar -Model Win-R etc). 71 Supply and fixing of Exhaust fan 9/10 size with making hole of required size. (Make-Havells/ Usha/ Almonard/ Orient/ Crompton/ Usha or equivalent). 72 Supply and fixing of Wall mounted fan 16 size. (Make-Havells/ Usha/ Almonard/ Orient/ Crompton/ Polycab or equivalent). 73 Supply & Fixing of 15Watt circular/ round recessed fitting(Make-Bajaj/ Philips / Crompton/ Havells/ Panasonic)(for Corridoor) 74 Supply & Fixing of 20Watt LED Tubet light (Make-Bajaj/Philips /Crompton/ Havells/Wipro/Halonix/Panasonic) 75 Supply & Fixing of 30Watt LED Tubet light (Make-Bajaj/Philips /Crompton/ Havells/Wipro/Halonix/Panasonic) 76 Supply & Fixing of 36Watt 2X2 Recessed fitting(Make-Bajaj/Philips /Crompton/ Havells/Wipro/Halonix/Panasonic) 77 Supply & Fixing of 60Watt LED street light (Make-Bajaj/Philips /Crompton/ Havells/Wipro/Halonix/Panasonic) 78 Supply & Fixing of 90Watt LED street light (Make-Bajaj/Philips /Crompton/ Havells/Wipro/Halonix/Panasonic) 79 S/F of 15 Amp Top 80 Sypply of 16 mm2 4 core alluminioum armoured cable (Polycab/ Havels/ KEI/ Finolex) 81 Supply of 16mm2 Cable Turmination 82 Laying of 16sqmm 4core Al. Arm Cable on wall Surface Horizental & Vertical 83 S/F OF100A/415V KIT KAT REWIREABLE FUSE TO BE INSTALLED AFTER ENERGY METER AS PER RECOMMENDATION OF WESCO ENGINEERS 84 (C)PH Work 85 Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge 86 25mm dia PVC ASTM pipe (sch-80) 87 32mm dia PVC ASTM pipe (sch-80) 88 Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materialsincluding cost & conveyance of all materials to worksite, payment oftaxes etc. allcomplete as per P.H specification and direction of the Engineer-in-charge. 89 15mm dia CP angle stop cock (FLR-ACR-5053N Jaquar make) 90 15mm dia CP two in one bib cock (FLR-CHR-5041N Jaquar make) 91 15mm dia CPbib cock (Jaquar Make) 92 25mm dia brassfull way valve (Shakti make) 93 32mm dia brassfull way valve (Shakti make) 94 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) 95 15mm CP Extension piece 96 125mm CP grating 97 15mm size C.P. flange 98 Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction ofEngineer-in-charge 99 2000 liters capacityPVC water storage tank 100 Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite,payment of royality, taxes etc. all complete as perdirection ofEngineer-in-charge. 101 Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge 102 Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damagesincluding watering ,curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. 103 Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment oftaxes etc.all complete as per P.H specification and direction of the Engineer-in-charge. 104 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) 105 110mm U-PVC‘P’ Trap(Ori Plast/Finolex/Supreme Make) 106 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) 107 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) 108 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) 109 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) 110 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) 111 110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make) 112 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) 113 Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI p or s trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 114 580mm size Orissa pan (Hindware/Parryware/Neycer make) 115 Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge 116 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) 117 Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral p or s trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 118 European water closet with p trap plain(Hindware/Parryware/Neycer make) 119 Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge 120 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with pedestal 121 Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink 122 Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 123 25mmx600mm long CP towel rail 124 Towel ring 125 Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. 126 600mmx125mm plate glass shelf with CP/NP guard rails. 127 Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 128 600mmx450mm size B.E mirror (swivelled type) 129 Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 130 CP soap holder 131 Supplying all materials ,labour ,T&P and constructing Inspection Chamber ofinside size 760mmx760mmx460mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge 132 Inside size 76cmx76cmx46cm with 18” dia RCC MH cover 133 Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. 134 Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge 135 Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed seriesto be pre-approved by the Engineer-in-charge ) 136 Kajaria/Somany/Johnson tile 30cmx30cm 137 Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. 138 Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirtingon 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge ) 139 Kajaria/Somany/Johnson tile 45cmx30cm 140 Providing fitting, fixing of Aluminium door with anodized AL. door section of 9202 as vertical member,9201 as top and 9200 as middle bottom member with frame section No. 9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle No. 1855 Including all Cost of Labour. T&P hire charges of drilling machine. labour charges etc. complete. Ref : OBI10 141 Ext. S/D Portion 142 Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufactures specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 143 100mm dia P.V.C. pipe 144 Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. 145 MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) 146 Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. 147 Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 40 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 40 liters along with noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge 148 Aqua guard pure Chill 40 PSS UV 149 1 no of 20 Users septic tank of size 2.30m x 1.10m x 2.10m Internal size 150 Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge.1 x 3.40 x 2.30 x 1.50 = 151 Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in chargewith 1st extra lift of 1.50 m over initial laft. 1 x 3.40 x 2.30 x 0.60 = 152 Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. 153 Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete. 154 1 x 3.40 x 2.30x 0.15 = 155 Supplying all labor T&P &Providing C.C. (1:2:4)with 12mm size brokenhard granite chips including watering curing &lead of all materials to site etc. all complete. 156 1 x 3.40 x 2.30 x 0.10 = 157 1 x 2.30 x 1.10 x 0.05 = 158 Supplying all labor T&P &Providing C.C. (1:2:4)with 12mm size brokenhard granite chips including watering curing &lead of all materials to site etc. all complete. 159 ProvidingC.C. (1:1½:3) with 12mm size hard granite chips of RCC workincluding hoisting and laying and curing with leadof all materials to site.1 x 2.80 x 1.60 x 0.10 = 160 Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges.0.448cum x 2.50x 35.32 = 39.55 kg say rs 161 Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor. 162 RCC floor, roof slab chhaja up to 4.430 m height 163 1 x 2.30 x 1.10 = 164 2(2.80+1.60) x 0.20 = 165 Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor. 166 Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site. 167 1st footing 168 2 x3.10 x 0.40 x 1.40 = 169 2 x 1.10 x 0.40 x 1.40 = 170 2nd footing 171 2 x 2.80 x 0.25 x 0.70 = 172 2 x 1.10 x 0.25 x 0.70 = 173 Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site. 174 Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site. 175 1 x 2.30 x 1.10 = 176 2(2.30+1.10) x 2.10 = 177 2(2.80+1.60) x 0.60 = 178 Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site. 179 Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site.Same as plastering 180 Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. 181 Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. 182 Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. 1 x 3.40 x 2.30 x 0.15 = 183 Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories 184 Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only 185 Drilling of 200mm dia bore 186 00 mtr to 30mtr 187 30 mtr to 45mtr 188 Drilling of 150mm dia bore 189 45 mtr to 213 190 Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. 191 200mm dia PVC pipe 192 00 mtr to 45 mtrs 193 Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber O ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. 194 200mm dia PVC (sch-80) pipe 195 Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) 196 Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge 197 By DTH Rig 198 Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: 199 Rocky terrain with boulder formation for 300m depth 200 Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 201 1H.P. Single phase/ three phase 3 stagehead renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm 202 DOL Control panel 203 40mm dia steel short piece 204 Well cap 205 50mm size CI bracket 206 2.50sqmm flat cable 207 Steel rope with cover 208 Labour charges for lowering including transportation 209 Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge 210 32mm HDPE pipes (Finolex/Supreme make)
Contract Date: Nov 25, 2025 Contract Value : 62.13 Lakh
Government Departments No of Bidders 3
9.
Public Administrative Department #8180958 AOC
Supply Of Laboratory Items For Govt. Model School, Dubrajpur, Birbhum , Supply Of Laboratory Items , Model Human Heart-Big Size - 10 Inch Pvc , Model-Dna/Rna - 10 Inch Pvc , Haemocytometer-Gdr , Jar Specimen Pinus-Male & Female - Plastic Jar , Jar Specimen Invertebrate, Hemichordate,Vertebrata - Plastic Jar , 3D Model Mammals Kidney, Lung, Heart - 10 Inch Pvc , Jar Specimen Venomous Snake - Plastic Jar , Simple Microscope , Fossil Specimen , Tripod Stand - Iron , Jali - With Asbestos , Measuring Cylinder - Bg 100 Ml , Conical Flask - Bg 250 Ml , Dropper(Glass) , Test Tube Holder , Slide Algae , Blood Slide(Human) , Yeast (Slide) , Bacteria (Slide) , Protozoa Slide , Monocot(Root & Stem Specimen Bottle ) - Plastic Jar , Dicot(Root & Stram Specimen Bottle) - Plastic Jar , Rabbit (Jar Specimen) - Plastic Jar , White Board - Magnetic-Resin Coated (6/4Ft.) Back Side Galvanized Sheet , Dpx Mountant - 250Ml (Merck) , Formal Dehyde Solution - 500 Ml (Merck) , Sarfrarin Solution - 125 Ml (Merck) , Crystal Violet Solution - 125 Ml (Merck) , Compound Microscope - 10X Eyepice 10X,45X,100X,Objective Mechanical Stage With Mirror , White Marker Board - Magnetic-Resin Coated (6/4Ft.) Back Side Galvanized Sheet , Zener Diode Set Up - Premium Quality , P-N Junction Set Up - Premium Quality , Travelling Microscope - Premium Quality , Ohms Law Apparatus - Premium Quality , Sonometer Ac Main With Power Supply - Premium Quality , Newton Cooling Apparatus - Premium Quality , Battery Eliminator - Premium Quality , Boyles Law Apparatus - Premium Quality , Resonance Tube - Brass , Bar Magnet - 3 Inch , Stokes Law Apparatus - Iron Stand , Glycerine For Store Apparatus - 2500 Ml (Merck) , Transistor - Apn/Pnp Complete Set , Surface Tension Experiment Apparatus - With Capillary Tube , Screw Gauge - Brass , Slide Callipers - Brass , Resistance Box - 5000 Ohms , Resistance Coil - 5,10 Ohms , Sphenometer - Brass , Inclined Plane Apparatus , Meter Bridge With Nichrome - Segun Wood , Steel Ball , Pendulum Set - Brass With Iron Stand , Youngs Modulus , Rheostat - 8 Inch & 20 Ohms , Galvanometer - Oxford , Voltmeter - Premium Quality , Dc Regulated Supply - Premium Quality , Concave Mirror - Premium Quality , Convex Mirror - Premium Quality , Hooks Law Apparatus - 2 Ft Set , Resonance Air Column - Wooden Board Heavy Type , Ammeter , Optical Bench - Steel Black Colour With Digital Print , Magnetic Needle , Lens Big Size , Lens Stand , Prism - Ordinary , Barometer - Premium Quality , Porous Rod , Spring Balance - 1 Kg , Tuning Fork - 8 Pc Set , Chemistry Laboratory Table With - Wooden Frame(3/3Inch Sall Wood) With Granite Top (6/4 Ft) With Standard Size Two Sink And Wooden Chemical Rack , White Marker Board - - Magnetic-Resin Coated (6/4Ft.) Back Side Galvanized Sheet , Burette - Straight Bore Stop Cock With Ptfe Key , Burette Clamp , Burette Stand With Clamp , Pipette - Borosilicate Glass (10 Ml) , Pipette - Borosilicate Glass (20Ml) , Glass Dropper , Plasstic Dropperi Long , Kipps Apparatus - Borosilicate Glass (1000 Ml) , Measuring Cylinder - Borosilicate Glass 100 Ml , Mortar & Pestle , Ph Meter - Pen Type (Digital) , Porcelain Dish , Reagent Bottles - Borosilicate Glass 250 Ml , Separating Funnel - Borosilicate Glass 250 Ml , Spirit Lamp - Steel , Tds Meter - Ordinary , Tongs - Steel , Chemical Balance - Analog For Chemistry , Chemical Weight Box , Cork Borer - Steel , Cricible , Round Bottom Flase With Glass Stopper - Borosilicate Glass 500 Ml , Tlc Plate , Beaker - Borosilicate Glass (250 Ml) , Beaker - Borosilicate Glass (100 Ml) , Conical Flask - (250 Ml) , Conical Flask - (100 Ml) , Thermometer - -40 To 260 C , Test Ture - Borosilicate Glass (15*125Mm) , Electrolysis Apparatus , Model Atomic Structure , 3D Globe - 1Ft , White Board - (Magnetic Backside Galvanized Sheet- Resin Coated) 4/6 Ft , Max And Minimum Thermometer - Zeal , Rock Set Box - 25Pc Set (Min Size 1.25Inch) , Dry And Wet Hygrometer - Zeal , Printed Map Political , Wind Vane Cock Type - 3.6Ft , Prismatic Compass - Brass Body , Clinometer Compass - , Scientific Calculator - Casio , Graph And Cartridge Paper , Diagonal Scale , Elementary Planetarium Model - Motorised , Solar System Simulator - Motorised , Dumpy Level With Stand Instrument - Metal Body , Day And Night Apparatus - Motorised , Altimeter - Digital , Hydrometer , Ph Meter - Hanna , Soil Testing Kit , Hygrometer - Zeal , Rain Gauge - Brass Body Set , 3D Model Precipitation - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Landforms Model For Mountain Plateau Plain - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Interior Of The Earth Model - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Volcanic System Model - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model Of Earth Movement Rotation And Revolution - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Solar Eclipse And Lunar Eclipse Model - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For Hydrological Cycle - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For Plate Tectonic Movement - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For Folds And Faults - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For Rock Cycle - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For River Courses - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For River Landforms - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For Glacial Landform - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model For Wind/Aeolian Landform - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model Or Charts For Weathering And Erosion - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Model Or Chart For Earthquake - 3D Model 8Pc Set (2 Sets Namely Gm1 And Gm2) , Topographical Map Or Toposheet (Preferably Plateau Region) , Map Of Climatic Regions Of India , Soil Map Of India , Natural Vegetation Map Of India , Agriculture Map Of India
Contract Date: Jul 31, 2025 Contract Value : 5.85 Lakh
Local Bodies No of Bidders 5
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 4.91 Lakh
Government Departments No of Bidders 8
13.
Water Resources and Irrigation #1489503 AOC
Hydrological Observation On The River Kangsabati At Kapastikri In The District West Midnapur To Be Conducted By River Research Institute Mohanpur During The Year 2019 20 , Hire Charges For Four Wheeler Non-A . C , B . S-Iii Type , With Diesel / Lpg Engine ( Up To 10 Hrs Of Duty Per Day ) Including Driver , Fuel , Mobil Etc . For Transporting Scientific And Other Survey Instruments From Rri , Mohanpur To Kapastikri In The District West Midnapur & Back To Hcl For Monitoring The Said Work From Haringhata & Back . , Hire Charges For Motor Van Including Driver , Fuel Etc . For Carrying Survey Instruments & Team . Daily 01 No . Motor Van . , Cost Of Casual Daily Unskiled Labour To Be Engaged In Connection With Discharge Measurement Of The River Kansabati At Kapastikri In The District West Midnapur . ( A ) Loading , Unloading , Packing And Repackaging ( B ) For Survey Work ( I ) For Taking Fly Level ( Ii ) For Taking Cross-Section Of Three Rivers . ( Iii ) For Velocity And Depth Measurement . , Cost Of Casual Daily Semi-Skilled Labour To Be Engaged In Connection Discharge Measurement Of The River Kansabati At Kapastikri In The District West Midnapur . ( A ) For Collection Of Bed Load And Suspended Load ( B ) For Simultaneous Observation In Three Rivers During High Discharge Period ( Approx . 20 Events ) , Cost Of Casual Daily Skilled Labours To Be Engaged In Connection With Discharge Measurement Of The River Kangsabati At Kapastikri In The Dist- West Midnapur . , Rented Boat Including Boat Man , Fuel Charges Etc For Kapastikri
Contract Date: Sep 30, 2019 Contract Value : 6.59 Lakh
Government Departments No of Bidders 3
West Bengal View Result →