View Bid Results For Hydro Electric Project Tenders

We found 387 Bid Results related to hydro electric project tenders. You can find Contractor details who won hydro electric project tenders along with contract details in Bid awards announcements section.

Filters
Stage
302
67
18
Tender Publishing Platform
24
363
State / UT
23
91
91
28
25
23
22
20
20
19
13
6
4
4
3
3
3
3
2
2
2
1
1
1
Contract Value
90
74
155
68
Publish Date
0
0
0
0
0
Sector
13
280
45
23
17
7
4
3
2
2
1
1
1
1
Ownership
5
220
157
4
3
3
Within keyword
Active filters:
Showing 1–8 of 387 tenders matching your filters
Contract Date: Jul 02, 2026 Contract Value : 43.97 Lakh
Government Departments No of Bidders 8
Maharashtra View Result →
3.
Heavy Industries and Public Enterprises #11394193 Technical Bid
Tender for D/G Eot Cranes Above 100T For Sunni Dam Hydro Electric Project
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Himachal Pradesh View Result →
5.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
7.
Heavy Industries and Public Enterprises #11164121 Technical Bid
Tender for D/G Eot Cranes Above 100T For 4X225 Mw Arun-3 Hydro Electric Project.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Uttarakhand View Result →
24.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Private Organizations No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Apr 16, 2026 Contract Value : 10.55 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
Contract Date: Apr 16, 2026 Contract Value : 13.93 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Mar 31, 2026 Contract Value : 2.56 Lakh
Boards / Undertakings / PSU No of Bidders 3
36.
Power #9921536 AOC
Tender For Material Supply, Spares & Special Tools - RGC - Construction of 33/110kV Step Up GIS at Pushpakandam-- 1 Design, Engineering, Manufacture, Testing at manufacturers works, Delivery at site including all materials, accessories such as OLTC,RTCC, with Transformer Oil and 10% extra Oil, spares,Gaskets, OTI,WTI,MOLG indicators with transducers and Tools as per specification , loading and unloading, transportation, handling, proper storage at siteThree Phase Two Winding Transformer33/110kV, 60MVA Capacity with optical sensors and Remote Data Transfer facility with optical communication media, and all other accessories complete, with SAS Integration Scope , all required valves and flanges for NIFPS shall be provided for transformer at the time of transformer design itself,inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 2 Design, Manufacture, Testing at Manufacturers works, Transportation and Delivery of 110 kV, 3 Phase Encapsulated Double Busbar Indoor Gas Insulated Switchgearequipmentand other accessories at Substation siteand as per respective Technical Specifications, Single Line Diagram, General Arrangement Drawings, IS/IEC standards, approval of KSEBLand relevant special conditions applicable. The quote for each bay shall include necessary interconnecting GI bus ducts within the building. The supply include all accessories of GIS bay, earthing materials for forming the earth grid inside the GIS hallas per standards of GIS earthing (Cu/Al), including RF Earthing, Cable tray, control cable from GIS to LCC, LCC panel, ladder etc. complete. 3 110 kV GIS Feeder Bay with PT(40kA/ 1250A min) 4 110kV GIS Double Bus bar arragement with PT(40kA/ 2500A min) 5 110kV GIS Bus Coupler Bay(40kA/2500A min) 6 110kV GIS Transformer Bay (40kA/1250A min) 7 Polymer housedSurge Arrester suitable for 110kV, 10kA, Class 3 withclamps, terminal connectors suitable for connection of any type of conductor or Al/cu pipe bus as per requirement, leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete 8 110kV composite solid core station post insulator , clamps, connectors etc suitablefor Al/ Cu Pipe Bus /Conductors. 9 Neutral CT (NCT) 36kV 3150Afor 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 1200-600/1-1 Amps(33 kV side) 10 Neutral CT (NCT) 36kV 3150A for 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 400-200/1-1 Amps(110 kV side) 11 UG power cable- 110kV, Single core, 630sqmm, Aluminium conductor,XLPE insulated,Aluminium Corrugated sheathedandHDPE Outer jacket under ground cable having rated short circuit capacity for both conductor and armourwith necessary Non - Magnetic , Metalic Trefoil/flat formation clamps atminimum 3 metre interval, steel/nylon cable ties wherever necessary 12 Outdoor termination kit suitable for 110kV, 630 Sqmm Single core Copper/ Aluminium UG cable for yard structure mountinginclusive of all accessories like earthing cable, suitable Non - Magnetic, Metalic clamp for fixing cable to support structure etc at 1m interval complete. 13 Indoor Plug in Type GIS termination kit for 110kV 630 Sqmm XLPE Single coreCopper/ Aluminium UG cable,inclusive of all accessories like earthing cable, suitable Non - Magnetic , Metalic clamp for fixing cable to support structure etc at 1m interval complete. 14 Supply of 4IPS Schedule 40 Al. Tube including requiredJointing Sleeves, Expansion joints, etc. withnecessary fixing clamp and all accessories complete for 110kV,33kV equipment to equipment connection 15 Three Phase Link Box 6.6kV withoutSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 16 Three Phase Link Box 6.6kV withSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 17 33kV Indoor composite VCBPanels having bus capacity 31.5 kA for 3sec, 3150A at STC continuous rating, 4 nos feeder bays having capacity not less than 1250A ,2 nos transformer feeder bays (for 33/110kV transformer) having capacity not less than 2000A ,1 nos transformer feeder bay ( for 33/11 kV5MVA Transformer ) having capacity not less than 1250A and1 nos bus coupler with bussection panel not less than 3150A, two bus PT panel at both side of the bus .Every feeder/incomer/ bus coupler shall have CT, E/S, synchro check, SEM Energy Meter, Ammeter, Voltmeter, Control and Protectionincluding earthing as per standards(Cu), cable tray, control cables etc completeand as per SLDand specifications. 33/110 kV 60 MVA Transformer feeder shall have provision for termination of cable size 3 runs per phase of 630 sqmm Aluminium cable. Each incomer panel (transformer) shall be provided with additional special protection class CT cores for differential protection scheme M1 and M2 at 110kV transformer C&R panel. All the feeders shall be remote controlled from SCMS and from the local console of the numerical relays with Bay Control Unit and protection unit including supply of the same. The supply includes one number VCBfor each ratings as spare (2000A, 1250A) and two numbers of service trolley for VCB , E/S, PT and spares (as per attached list clause 6.6 & 6.7 of volume 2, Chapter 27). 18 Polymer housedSurge Arrester suitable for 33kV, 10kA, Class-3 with clamps, terminal connectors etc. suitable for connection ofany type of conductor or Al /Cu pipe bus as per requirement, including leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete (33kV Feeder/ Transformer) 19 33kV 800A Triple Pole Line Isolator with Structure, clamps, terminal connectors etc. suitable for connection of any type of conductor or Al/Cu pipe bus as per requirement 20 33kV Pin insulator with pin 21 33kV composite solid core station post insulator with high level structure with clamp & connectors suitable for Al pipe/conductor. 22 UG power cable- 33kV 1Cx630sqmm Aluminium 33kV, XLPE Aluminium armoured having rated short circuit current capacity for both conductor and armour and HDPE outer jacket for 33/110kV 60MVA transformer incomer with necessary Non-magnetic, metallic, Trefoil/flat formation clamps at minimum 3 metre interval and steel/nylon cable tie wherever necessary 23 Outdoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core Aluminium UG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 24 Indoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core AluminiumUG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 25 Design, Engineering, manufacturing, testing at Manufactures worksite, supply, delivery,loading and unloading, transportation, handling, proper storage at site,supervisionof erection, testing and commissioning of 33/11kV, 5MVA three phase two windingtransformer as per technical speciationsincluding all materials, accessories such as Off Load Tap Changer, Transformer Oil and 10% extra Oil, spare Gaskets, OTI,WTI,MOLG indicators with transducers as per specification and Remote Data Transfer facility with optical communication media, with SAS Integration Scope , inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 26 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 200/1-1 Amps (33kV side) 27 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 300/1-1 Amps (11kV side) 28 Alumimium UG Cable- 33kV, 3Cx300 sq.mm XLPE insulated, Galvanised steel strips armoured power cable for feeders / Aux Tfr with necessarymetallic, non magnetic clamps atminimum 3 metre interval, steel/nylon cable tie wherever necessary 29 Outdoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPE Galvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 30 Indoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPEGalvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 31 Distribution Transformer 11kV/433V, 250 kVA, Star rated (BEE Latest notification as on date of tender)with 11kV & 433V outdoor cable entry box, suitableDistribution Box with LT cable (Trfr to LT box) with 500Amps Fuse and MCCB including all accessories like Busbar, Metering Cabinets etcand its fixing -mounting arrangement on plinth 32 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches and one Vacuum/SF6 breaker suitable for 11KV/433V Auxillary Transformer/ Outgoing feederas per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 33 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches as per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 34 Supply of 11kV indoor VCB 5 panel set with combinations of Incomer feeder panel with PT (1 number), Outgoing feeder panel (3 number) and transfomer panel (1 number) with bay control and protection unit (BCPU) for integration with upstream Substation Automation System (SAS) through HSR/PRP topology (IEC 61850 edt 2 compliant) with protection philosophy specified in technical specification along with supply of accessories necessary for operational spares and special tools (as per attached list clause 37.6 & 38 of volume 2, Chapter 30). Bus Bar ratings are 2000A. Circuit breaker shall be E2 M2 C2 class as per IEC 62271-200. Feeder, transformer and incomer panel shall have capacitive voltage indicators (CVI) and only incomer panel BPCU will have PT inputs. Feeder,transfomrer and incomer panels shall house one each multi-function meter (MFM) and DLMS compatible energy meters. Each Incoming and outgoing feeders shall be equipped with split core type CBCT for Sensitive Earth Fault Protection 35 Supply of Polymeric type LA suitable for 11kV 36 3Cx300sqmm 11kV Aluminium XLPE insulated under ground armoured cable, with necessaryclamps for fixing with support structure at 3 m interval 37 3Cx300sqmm11kV Aluminium XLPE Under ground cable Termination Kit Outdoor Heat Shrinkable 38 3Cx300mm2 11kV Aluminium XLPE Under ground cable Termination Kit Indoor Heat Shrinkable 39 Supply of Hot dip Galvanised LatticeStructurefor 33kV,11kV& 110 kV Switch Yard, Columns/Beams/Pre fabricated Cable Supports in Trenches/lightning mast structure/ lighting mast structure/ equipment structures unless otherwise not specified else where in the BOQ etcinclusive of N&Betc(as per respective Technical Specifications, standards and relevant special conditions). 40 EOT Crane of suitable capacity (minimum 5T safe working load) with single hook and double girder arrangement for GIS Hall. Contractor shall submit the capacity calculation of the crane incorporating 25% additional load considering erection and maintenance of largest GIS component / assembly. 41 DG set 125 kVA silent type, Outdoor plinth mounted withAMF panel, Auto Load Change over module and panels, Battery and its charger, Diesel Tank etc with SAS integration facilities including all accessories complete 42 Battery Set - 110 V, 400Ah , Lead Acid plante Battery SetC10 Duty cycle (Rating is tentative and final sizing as per the load calculation shall be under bidder scope) & Installationwith Battery Racks made with acid proof material ,two number of indsutrial type flame proof exhaust fan and all necessary arrangements including tool kit like hydro meter, chemical gloves, multimeter etc. 43 48V, 200 AH VRLA Battery Set with all associated accessories for reliable communication & data acquistion project complete as per specifications 44 SCADA compatible 110V Dual mode (FC+ BC) Battery Charger, with independent Float (FC)and Boost charging (BC) (2 number rectifier unit) min-FC-80A, BC-80A, suitable for 110V Battery bank as per design and shall charge Battery set as per technical requirement during float /boost mode without interruption to load. The charger shall have two independent incomer supply.(Battery charger shall meet the full DC load during boost condition and the Bidder shall propose the final sizing of the battery charger during detailed engineering for approval)(Both set shall be of different make ) 45 Battery Charger - 48 V Dual mode (FC+BC) (Float - 30A/Boost - 60A) - SCADA compatible, SMPS based,Suitable to VRLA Battery set and shall be able to charge Battery set as per requirement during float /boost mode as well as it shall supply to load as per rated voltage of load components inclusive of necessary power, communication and control cables with all accessories complete -Compact type 46 SCADA compatible DCDB-110 V with minimum 20 + 20 Outgoing feeders duplex type (Floor Mountable) with changeover panel having interlock facility with 20% spare feeder breakers for station control and protection systems as per the station requirement, facility shall be there to charge any battery set with any of the battery chargerwith interlock. Ratings shall be as per the battery sizing calculation. 47 DCDB 48 V with change over facility and min 20 Nos. of Distribution Outlets( 2 Nos.- 10A and 18 Nos. 6A)-DUPLEX Type-SCADA/SAS Compatible-Wall mountable 48 SCADA compatible LT 3 phase 50Hz Panel Boardwith Insulated Aluminium Bus Bar, 2 nos incomers (Auxillary Transformer / DG Set), automatic interlock/load change over facilty, two sets of outgoing,panel with LED indications, panel meters,ACB /MCCB(incomers), MCCB (feeders), Earth Bus bar etc., for LT Power Distribution to Control room/equipments including all accessories complete as perspecifications having minimum 20% spare feeders.Remote operation shall be possible for incomers and DG set.(Panel sizing and rating to be proposed by the bidder during detailed engineering for approval). 49 SCADA compatible LT MLDB/LDB/Street light control DB with Lighting Transformer, Surge Protection Devices, MCCB, MCB, RCCB, ELCB and all accessories complete as per technical specifications for Control Room and Yard lighting including all sub distribution boards, and SCADA compatible ACDB/Sub ACDB for Air Conditioners & AHU with soft starting feature etc. including MCCB, MCB, RCCB, ELCB. (The DB sizing and rating shall be proposed by the bidder, with 20% spare capacity, during detailed engineering for KSEBL approval) 50 SCADA compatible LT Emegency Lighting Distribution Board (ELDB) with 63A Incomer and minimum 12Nos 10A Outgoing Feeders and DC Emegency Lighting Distribution Board (DC ELDB) and related accessories including MCCB/MCB,RCCB/ ELCB as perstandard specifications for Emergency lighting in the substation / Switchyard, charges including all sub distribution boards 51 LT A.C Three Phase Self mounted Indoor Power Kiosk IP 42 with 1 incomer MCCB 63A including indicating lamps,single phase and three phaseindustrial type16A sockets etc. at GIS hall 52 LT A.C Three Phase Self mounted Outdoor Power Kiosk (IP 56) with 1 incomer MCCB 250A, 2 Outgoing MCCB 160A & 100A including indicating lamps,3 phase and singlephase industrial type 16A sockets etc. complete for Transformer oil filteration unit, welding purpose etc. 53 Supply of Protection Panels/Equipments, Substation Automation System and materials as per technical specifications, IS/IEC Standards applicable 54 Control and Protection panel for Transformer with Differential Protection,REF (Transformer management relay) for HV and LV [M1 and M2 relay shall be of different make / platform and each shall have-87, 67/67N, 64R-Low Impedance, Transformer Mechanical Protection- Bucholz, OLTC Bucholz, OLTCPanel Control & signal interfacing with RTCC panel, OTI, WTI, PRD1 &2 through high impedance tripping relays, MOLG Alarms etc.,] 33/110kV 60MVA, with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA system. Energy meters as per technical specifications and suitable for GIS switchgear modules 55 Busbar Protection panel for8 bays (110kV Bus) as per specifications -with zone segregated tripping, LBB, end zone protection, local HMI for displaying differential current, SLD, Isolator Position etc., with output tripping relays (drawout type) and provision for interface to SCADA/SAS system 56 Control and Protection panels (main 1 and 2- 87L,21,67/67N,50N,59,PSB, 79A/R,49,81 O/U) for 110kV Feeders with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA systemas per tech specifications and suitable for GIS switchgear modules (M1 and M2 relay shall be of different make / platform and the combination shall exactly suit with the remote end M1 and M2 relays). Over and above the normal Tri-Vector Meter, the contractor should supply SEM Meters as per SRLDC/PGCIL Standards, additionally. 57 Control and Protection panel for 110kV Bus Coupler with BCU and additional Common BCU for Auxiliary control System and Monitoring including the panel as per standard and requirement of 110kV GIS 58 Design, Manufacture and Supply of Complete SAS system for 110kV GIS , as per detailed technical specification , SAS system Architecture andSLD , Reduntant Servers, Reduntant Gateway, Reduntant Routers with Hardware Firewalls,2 Nos Operator Work Station with HMI -Desktop (one operating work station with extended HMI at Nedumkandam (10Km away)) , 2 Nos. Engineering Work Station(Lap top and Desk top) , one metering PC with DCU for SAMAST metering and Remote Station Controls, necessary Panels and Furnitures etc completewith all necessary accessories, cables,converters, GPS based Time Syncronising Unit IEC compatible to cater data to and from all bays and transformer, SCADA compatible panels,interfacing /intergating line differential relay in CR panel, SAS gateway server panel etc to FODP/Communication equipment in communication room as per specification, including supply of all necessary converters for interfacing with the communication equipment , unarmoured OF cable , 40mm PLBHDPE pipe duct , all interconnecting cables , Patch chords devices etc. complete. The scope include integrating 33kV and 11 kV systems.SAS Architecture should be suitable for plug and play integration of future bays. [Including mandatory Spares as specified in volume 2 - Technical Specfications, Chapter 11, Annexure C] 59 Design, Manufacture and Supply of materials / item for Power Cable, Control Cables and instrumentation cable, Supply of various sizes of 1.1 kV FRLS-0H PVC armoured copper cable for control , Aluminum/ Copper LT power cable as per approved cable schedule (to be prepared by contractor and got approved), and provision of all types of cables from Power and Auxilliary Transformer and other equipments/switchgears, for the substation (Aluminium cables of size 185 mm2 and above shall be XLPE type) includingties , tags etc. supply of suitable size PVC pipe and accessoriesfor drawing exposed cables as per the technical specifications, IS/IEC Standards applicable. 60 12x4mm2 Control CableCopper 61 4x6mm2 Control CableCopper 62 4x4mm2 Control Cable Copper 63 2x4mm2 Control Cable Copper 64 19x2.5mm2 Control CableCopper 65 12x2.5mm2 Control Cable Copper 66 7x2.5mm2 Control Cable Copper 67 4x2.5mm2 Control Cable Copper 68 3x2.5mm2 Control Cable Copper 69 2x2.5mm2 Control Cable Copper 70 2x1.5mm2 Control Cable Copper 71 4x0.5mm2 instrumentation Cable Copper 72 4x10mm2 PVC InsulatedLT copper cables 73 2x10mm2 PVC Insulated LT copper cables 74 2x1.5 sq.mm or higher size PVC Insulated shielded copper cables for Transformer OTI & WTI wiring 75 20/25 mm dia FRLS PVC Rigid/Flexible Conduit including all clamps, clips etc. for Fire Alarm Panel and sensor wiring purpose 76 3 1/2C x300 Sqmm 1.1kV LTXLPE insulated armoured Aluminium cable 77 3 1/2C x 240 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 78 3 1/2C x 120 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 79 3 1/2C x 90 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 80 3 1/2C x 70 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 81 3 1/2C x 50 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 82 3 1/2C x 35 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 83 3 1/2C x 25 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 84 4C x 16 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 85 1x 95 sqmm DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 86 1x 70 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 87 1x35 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 88 Supplying aluminium cable tags with punching number and alphabets up to 7 digits or higher as per requirement for 220/33/11kV power cables including cost of all materials as per the technical and standard specifications 89 Hot dip galvanized ladder type cable tray with joint plate and N&B size300x100x2 with all accessories complete 90 Hot dip galvanized ladder type cable tray with joint plate and N&B size 450x100x2and with all accessories complete 91 Hot dip galvanized ladder type cable tray with joint plate and N&B size600x100x2 and with all accessories complete 92 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Conductor/ Earthing Materials and associated materials for Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable 93 Aluminium Bus bar 120*10mm 94 ACSR Wolf Conductor 95 110 kV 90kN Silicon Composite Longrod Insulator 96 110 kV 70kN Silicon Composite Longrod Insulator 97 110 kV Single Tension H/W and Accessories suitable for Single Wolf 98 110 kV Single Suspension H/W and Accessories suitable for Single Wolf 99 wedge – connector suitale for wolf/Kundah 100 wedge with paddlesuitale for wolf/Kundah 101 Earth Wire 7/3.15 mm Galvanised Steel wire with required hardwares accessories and earthbond 102 Tension Clamp and Tail Clamp for 7/3.15 mm Earth Wire 103 32/40mm MS rod for earthing 104 GI strip all sizes as per requirement for earthing 105 Clamp and saddle for GI strip/wire 106 Test link for lightning protection 107 1.5m GI lightning spike with fixing clamps 108 Design and supply ofVentilation system for GIS hall(positive pressure type)with prefilters and fine filters of washable type for 100% capacity of GIS hall, with air displacement of 5 times the volume of GIS hall per hour (one operating + one standby , consisting of two units each having capacity 5 times air changes per hourof GIS hall workingcyclically for 50% of time)with soft starting feature,comprising of GI ducts( with provision for nitrile rubber insulation if taken externally), fire dampers, exhaust dampers, grills, noise reduction system etc. complete.The system shall be monitored via SCADA including necessaryelectrical panels. 109 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Fire and Safety Equipments and materials for 33/110kV Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable- Portable and wheel/ trolley mounted fire extinguishers for Control room 110kV GIS Hall, 110kV Switchyard Relay panel room of GIS Hall,Transformers and other Strategic locations including its installation at site 110 Dry chemical powder of 9kg capacity 111 Dry chemical powder of 25kg capacity 112 Dry chemical powder of 50kg capacity 113 CO2 gas type of capacity 6.5kg 114 CO2 gas type of capacity 22.5kg 115 Mechanical foam type capacity 9LT 116 Mechanical foam type capacity 50LT - 117 Fire Stand with 4 buckets(Including Concreting as per drawings) 118 SCADA compatible - Main Fire Alarm Control Panel (Zone of protection as per approved scheme) complete with Charger, Rectifier, Visual Display, battery back up complete as per the station requirement 119 Photo Electric type Smoke detector with base compatable for Fire Alarm Panel 120 Photo Electric type Heat detector with base compatable for Fire Alarm Panel 121 Supply of Beam Detector and Reflector for GIS with base compatable for Fire Alarm Panel 122 Audio Alarm with Hooters cum Speakers compatable for Fire Alarm Panel 123 Manual Call point of Break Glass Type with hammer and chain 124 Insulating Mat (Size 2000x1000x2mm) class A including its fixing at site as per Technical Specification and IS 125 Safety Chart for First Aid, Electric Shock & Fire and Fire Fighting Equipments including its fixing accessories complete 126 Lighting and General / Miscellaneous Items 127 Optical Fibre Cable (12F Single Mode and 12F Multimode) , SM and MM Patchcords, all necessary connectors complete, as per site requirement for extended HMI, bus bar protection other than SASas per site requirement and technical specification 128 Ground Enhancement Material (GEM) ( Per Bag -11.33 Kgs ) - Conforms IEC 62561-7 Standard. The GEM shall have Resistivity of less than 20 Ohm-cm and Environmental friendly 129 Visual Monitoring System (VMS) with surveilliancecamera as per technical specification and layout drawing (Including local PC monitoring set up having sufficient storage capacity, remote end PC monitoring if necessary set up shall be in the scope of supply) including necessary power and communicationcables, interconnecting hardwares, PVC pipes and all other accessoriesetc complete as per the technical specifications (minimum requirement : Fixed Camera : min 8 Nos, Pan Tilt Zoom Camera : min 2 Nos, Fixed Variable Focus: min 4 Nosand storage >8TB) 130 Design of Air Conditioning system and Supply of5 Star rated (as per latest BEE notification)2TR or higher capacity split type inverter Air Conditioners, with stabilizer, Power Isolator etc.for Control & Relay panel room, Communication room, SCADA room, Bay Control Room (each room has got minimum one unit of redundancy, cyclically operated with Room temperature indicator) as per detailed engineering and approval. Temperature indicators shall be integrated to SCADA 131 SPARES for GIS - 220/110kV 132 Tripping & closing coil(Each Breaker type Module) 133 Motor for disconnector of each type of equipment 134 Motor for CB spring charging (each Breaker Type) 135 SF6 Pressure Guage for Circuit Breaker 136 SF6 Pressure Guage for other compartments 137 SF6 Pressure Relief Device 138 Auxillary contact assembly for Circuit Breaker 139 Auxillary contact assembly for Disconnector/Isolator-each type 140 SF6 gas 141 Moisture absorbant catridge 142 NRV gas filling valve for equipment 143 Indication lamps and lamps for semaphores & annunciators- one for each type & colour 144 Annunciator full set each type with one set of relay card 145 Special tools for Installation and Maintenance -220/110kV 146 Gas Leakage detector - DILO make 147 Special spanners for General maintenance for supplied GIS 148 SF6 gas bottle locking , measuring and filling assembly with whole hose 149 Measuring Instruments 150 Clamp on meter- capable to measure mA range .• High sensitivity, miniature AC/DC clamp meter.Range: 200mA/2/20A AC, 2/20A DCMin. resolution for AC: 0.1mAMin. Resolution for DC: 1mAJaw size: 7.5mm all required accessories from following make and model Fluke,MEGGER,KYORITSU 151 Phase Sequence meter with Standard accessories -Fluke,MEGGER,KYORITSU 152 Digital Multimeter 279FC TRMS Thermal or advancedFluke,MEGGER Model 153 Analog Multimeter, with Standard accessories - Fluke,MEGGER,KYORITSU 154 SF6 gas Analyser including DEW point,purtity & Hygrometer etc.
Contract Date: Apr 01, 2026 Contract Value : 369.42 Crore
Boards / Undertakings / PSU No of Bidders 8
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttarakhand View Result →
Contract Date: Feb 13, 2026 Contract Value : 8.01 Lakh
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Feb 17, 2026 Contract Value : 11.57 Lakh
Boards / Undertakings / PSU No of Bidders 4
48.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
Contract Date: Mar 20, 2026 Contract Value : 2.02 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
TenderDetail
Loading tenders