View Bid Results For Heat Detector Tenders

We found 916 Bid Results related to heat detector tenders. You can find Contractor details who won heat detector tenders along with contract details in Bid awards announcements section.

Filters
Stage
715
132
69
Tender Publishing Platform
335
581
State / UT
33
128
107
75
59
51
51
51
46
38
32
31
31
30
27
20
20
16
16
15
13
10
9
9
8
6
4
4
3
2
1
1
1
1
Contract Value
264
276
259
115
Publish Date
3
0
1
0
0
Sector
32
200
119
113
90
74
72
58
21
19
19
17
17
14
13
12
10
9
7
5
4
3
3
3
3
2
2
2
1
1
1
1
1
Ownership
6
438
211
183
75
7
2
Within keyword
Active filters:
Showing 1–19 of 916 tenders matching your filters
1.
Housing Urban and Rular Development #11475953 Technical Bid
bill of quantities (boq) for renovation of toilets at eight floors (ground floor, 1st, 2nd, 3rd, 4th, 5th, 6th & 7th floors) and pantry at 8th floor of ncdc headquarters building, 4, siri institutional area, august kranti marg, new delhi – 110016 schedule a- civil works sl. no. description of items unit quantity rate amount sub-head : 1 dismantling / demolition works , dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , dismantling tile work in floors,walls and roofs laid in cement mortar including stacking material within 50 metres lead. , dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead , of area 3 sqm. and below , dismantling old plaster or water proofing or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar , dismantling of flushing cistern of all types c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. , vitreous china water closet indian / european , vitreous china wash basins / urinals , dismantling existing floors of bathrooms and toilets as per instructions. the cost inclusive of stacking of dismantled materials (serviceable material) in good condition and also disposal of broken unserviceable materials at contractors own place. , dismantling of existing cp brass fittings, bottle traps and existing gi & ci pipes / fittings, wherever required in toilet as per instructions. the cost inclusive of stacking of existing brass fittings as per instructions of engineer - in - charge and the location directed by him. , dismantling & removal of malbaa from the sunken areas including stacking of serviceable and unserviceable material separately in the lead of 50 mts.after digging the same till the existing waterproofing is visible. the unserviceable material (inclusive of existing waterproofing, if any, of any nature) shall be removed from the sunken areas and the contractor should stack the same at his own place. sub total 0.0 sub head:2 wood work , providing and fixing wood work in frames of doors, windows, celestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). a. sal wood , providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including isi marked stainless steel butt hinges with necessary screws , extra for providing and fixing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter is to be measured for payment purpose). sub total 0.0 sub head:3 finishing work , providing and applying 12mm cement plaster including making grooves wherever required of mix 1:6 . (1 cement :6 coarse sand) , brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand) , providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer-in-charge. , 12.5 mm thick square edge pvc laminated gypsum tile of size 595x595 mm, made of gypsum plasterboard, manufactured from natural gypsum as per is 2095 part i and laminated with white 0.16mm thick fire retardant pvc film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side pvc film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. , providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. size of tile 800x800 (note: a. base rate of tile in the range of rs.90-95/- per sq.ft. b. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 800x800 mm (note: a. base rate of tile in the range of rs.90 -95 per sq.ft. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. completeat all levels.granite stone slab of colour black, cherry/ruby red , providing and fixing1500x500 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed towooden cleats with c.p. brass screws and washers complete.mirror make:asahi, saint gobain or equivalent as approved by engineer in charge sub total sub head:4 waterproofing work , providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: (i) ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv)ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). , providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. , supplying and filling in sunken with sand under floors, including watering,ramming, consolidating and dressing complete. sub total 0.0 sub-head : 5 plumbing / sanitary work , providing and fixing white vitreous china pedestal type water closet(european type-one piece) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flushbend, overflow arrangement with specials of standard make and mosquitoproof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floorswherever required : w.c. pan with isi marked white solid plastic seat and lid , providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required:white vitreous china orissa pattern w.c. pan of size 580x440mm with integral type foot rests , providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (i)white vitreous china wash basin size 630x450 mm with a pair of 15 mm c.p. brass pillar taps , providing and fixing white vitreous china flat back half stall urinal of 710x485x300 mm or 640x370x310 or 610x390x370mm sizes with white pvc automatic flushing cistern, with fittings,standard size c.p. brass flush pipe, spreaders with unions and clamps (allin c.p. brass) with waste fitting as per is : 2556, c.i. trap with outlet gratingand other couplings in c.p. brass, including painting of fittings and cuttingand making good the walls and floors wherever required : range of two half stall urinals with 10 litre p.v.c. automatic flushing cistern , providing and fixing stainless steel a isi 304 (18/8) kitchen sink as peris:13983 with c.i. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the walls wherever required :kitchen sink with drain board 510x1040 mm bowl depth 225 mm , providing and fixing stone slab with table rubbed, edges rounded and polished,of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting achase of appropriate width with chase cutter and embedding the stone in thechase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 6 mm nominal size) as per direction of engineer-in-charge and finished smooth. (granite stone of approved shade) , providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or quivalent make) , 15mm nominal outer dia. pipes , 20mm nominal outer dia. pipes , 32mm nominal outer dia. pipes , 50mm nominal outer dia. pipes , providing and fixing 3 layer pp-r (poly propylene random copolymer)pipes confirming to is:15801 uv stabilized & anti - microbial fusion welded,having thermal stability for hot & cold water supply, including all pp - r plain & brass threaded polypropylene random fittings, including trenching,refilling & testing of joints complete as per direction of engineer-in-charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or equivalent make) , 100mm nominal outer dia. pipes , 150mm nominal outer dia. pipes , all internal sanitary works , providing and fixing c.p. brass long nose bib cock of approved quality (15 mm nominal bore) , providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 , providing and fixing brass 2 in 1 pillar cock of approved quality (15 mm nominal bore) sub total 0.0 total sch a 0.0 schedule b- elctrical works sl.no. description unit quantity rate amount (in rs.) , wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable etc. as required.(wire make- havells, polycab, finolex or equivalent. modular switch, socket, box, plate, etc make- havells, roma or equivalent. steel conduit make-bec, unicon or equivalent) , group c , wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/recessed steel conduit as required.(wire make- havells, polycab, finolex or equivalent) , 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire , supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.(make- havells, schneider or equivalent) , 250 mm x 300 mm x 100 mm deep , 180 mm x 100 mm x 60 mm deep , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(make- havells, roma or equivalent , 3 pin 5/6 a socket outlet , 5/6 a switch , 15/16 a switch , 6 pin 15/16 a socket outlet , supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc. as required.(make- havells, finolex or equivalent , 8 module (125mmx125mm) , 12 module (200mmx150mm) , 6 module (200mmx75mm) , installation, testing and commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(make- havells, crompton or equivalent , 510 mm sweep , led down lighter (cob type) (system lumen efficacy ≥120 lm/watt ) supplying, installation, testing & commissioning of led recessed/surface down lighter (round / square/ rectangular) cob type of following body material and construction as per is : 10322 with driver as per the requirement with driver efficiency 85%, operating voltage ac 140-270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10%, p. f.≥0.95, ip20, cri 80 , ugr (unified glare rating) 19, flicker free (flicker should be below 5 %), life time (led, driver & electrical circuitry), life time of minimum 50000 burning hours with, 70% of initial lumen maintained till life ends , cct 3000°k / 4000°k / 5700°k /6500°k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted shape size and cct shall be as approved by engineer-in- charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). powder coated die cast /extruded aluminium body including trim with aluminium reflector(make- havells, philips or equivalent) , 12 -15 watt , led batten light (system lumen efficacy ≥120 135 lm/watt) supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency 85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f.≥0.95, ip20, cri 80, flicker free (flicker should be below 5 %), life time (led,driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000°k / 4000°k / 5700°k /6500°k 46 delhi schedule of rates (e&m)-2025(as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output. lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c).powder coated die cast /extruded aluminium body (thickness 1.20 mm)(make- havells, philips or equivalent) , 18- 22 watt , led strip light (make- philips, wipro or equivalent) , automatic hand dryer (make- dolphy, euronics or equivalent) , automatic touchless toilet urinal sensor alongwith solenoid valve, flexible hose, etc(make- parryware, jaquar or equivalent) total sch b total total (sch a+schb) 0.0 say rs.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 5
5.
Defence #11392756 Technical Bid
Tender for Demolition Of Brick Work /Stone Masonry Masonry Built In Cement Mortar Of Any Description Complete All As Specified And As Directed. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc Complete All As Specified And As Directed. , Taking Down Shutters Of Any Description Exc 1 Sq. M And N Exc 2 Sq. M Each Removing To Store Complete All As Specified And As Directed. , Demolition Of Cement Concrete And Paving Not Exc 15 Cm Thick (Below Or Above Ground Level) Complete All As Specified And As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area N.Exc. 1.5 Sqm Including Builders Hardware Each Complete All As Specified And As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each Including Builders Hardware Complete All As Specified And As Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering Complete All As Specified And As Directed. , Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Etc Complete All As Specified And As Directed , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed. , Taking Down Cement Plaster Of Any Description Hacking For Key Or Raking Out Joint On Old Brick Work/ Stone /Concrete Surface Etc Complete All As Specified And As Directed , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding But Not Backing Complete All As Specified And As Directed. , Excavating In Post Holes (Or Similar Holes) Each Not Exceeding 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50M And Making Good Surfaces In Soft/Loose Soil Complete All As Specified And As Directed. , Material And Labour For Sand Filling Under Floors Or In Foundations Including Watering And Consolidation Under Bedding For Interlocking Tiles Etc Complete All As Specified And As Directed , Material And Labour For Plain Cement Concrete Type D-2 1:4:8 (With Using 40 Mm Graded Stone Aggregates) As In Foundations And Mass Concrete Etc Complete All As Specified And As Directed , Material And Labour For Providing Cement Concrete Type B0 1:2:4 (Using 12.50Mm Graded Stone Aggregate) In Copings, Parapets And, Kerbs, Water Troughs/ Chajjas And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating As Directed , Material And Labour Brickwork (Old Size Brick) With Sub Class ‘B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:4 Etc Complete All As Specified And As Directed , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Jambs, Pillars, Window- Cills,Cooking Platforms, Working Table And Like Over 20 Mm Thick Screed Bed Or Bedding Layer In Cement Mortar (1:4), Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite , Material And Labour For 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) For Wall Lining (Veneering To Wall) 10Mm Thick In Cement Mortar (1:3) And Pointing With White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. , Supply And Fix 30 Mm Thcik Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified And As Directed. , Supply And Fix 30Mm Thick 2Nd Class Hw Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc.Divided Into Squares, With Plain,Chamfered Or Rounded,Mitred And Rebated Sash Bars,Any Numbers, Edges Of Framing Plain,Chamfered Or Rounded. Fitted With Cut And Mitred Beads For Securing Glass,Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats Complete All As Specified And As Directed. , Supply And Fix Solid Pre Lam Pvc Door Frame/Chowkhat Of Size 50 X 47Mm Made Out Of 5Mm Prelam Pvc Sheet Reinforced With M.S. Square Tube 15Mm X 15Mm. The Two Vertical Door Profiles Are To Be Reinforced With 40Mm X 20Mm Ms Tube 19 Guage. Door Frame Need To Be Fixed To Wall Using 100 Mm Long Ms Screws Etc Complete. , Supply And Fix Factory Made Solid Panel Pre Lam Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes 19 Guage Thickness And Size Of 40Mm X 20 Mm For Stiles, Top,Bottom And Lock Rails. M.S. Frame Shall Be Covered With Heat Moulded Prelam Pvc ‘C Channel Having A Pvc Sheet Strip Of 30Mm Width Stuck Inside With Solvent Cement. 110 Mm Width Forming Stiles In Which 100Mmm Should Be Flat And 5 Mm Should Be Tapered, And 5 Mm Thich, 135 Mm Wide Prelam Pvc Sheet For Top And Bottom Rail In Wchich 125 Should Be Flat And 5 Mm Should Be Tapered On Either Side Of Panel, Also For Lock Rail 145 Mm Sheet, 125 Should Be Flat And 5 Mm Tapered On Either Side. And Additional 5 Mm Thich Pvc Strip Struck Inside Of C Channel. And Prelam Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Prelam Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement Etc Complete , Supply And Fix 100 Mm Size Stainless Steel Butt Hinges, Complete All As Specified And As Directed. , Supply And Fix 200 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Extruded Aluminum Alloy Handles, Fabricated Type, Anodized Complete All As Specified And As Directed , Supply And Fix 300 Mm Long Aluminum Alloy Anodised Sliding Door Bolt With Hasp, Staple (Bolt Type) And Fixing Clips Of Steel, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminum Alloy Complete All As Specified And As Directed. , Supply And Fix Stain-Less Steel Wire Cloth, 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40 Mm And Fixed With Stainless Wire Staples Complete All As Specified And As Directed. , Supply And Fix As In Repair Aluminium Extuded Section Body Door Closer Hydraulically Regulated, Designation No. 3,Universal Type, Suitable For Door Shutters Of 851 To 1000 Mm In Width And Of Weight Between 61 To 80 Kg Complete All As Specified. , Taking Down And Refixing Aluminium Window, Shutters And Making Unserviceable Shutter To Serviceable Shutter (Which Incls Replacing Roller,Rubber Beading Etc) Complete All As Specified And Directed. , Providing And Fixing Powder Coated Aluminium (Minimum Thicknesss Of Powder Coating 50 Micron) Work For Doors, Windows, Ventilators And Partitions (Fixed Portions) With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Confirming To Is-733 And Is- 1285, Fixed With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E At Top, Bottom And Sides With Required Epdm Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified, Supplied And Fixed , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified, Supplied And Fixed , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Trusses, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And/Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.Gde-E-165 Complete All As Specified And Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed Note: To Be Executed For Provison Of Ridges And Hips, Valley Etc Complete All As Specifed And As Directed , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour For Machine Presssd Pre-Cast Concrete Interlocking Coloured Paving Block Of Glass Fibre Reinfoced Glossy Finished Vibro Compacted Any Shape And Size Confirming To Is-15658-2006 Of 60 Mm Thick, M-35 Grade To Match With Grey Cement And Pigment Etc Complete All As Specified And As Directed , Material And Labour For Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:6) Complete All As Specified And Directed. , Supply And Fix For Exterior Grade, Coloured Glossy Finish Rubber Pressed, Cement Concrete Designer Chequered Tiles Of Size 300Mm X 300Mm X 25Mm Thick Set, Jointed And Pointed In Neat Cement Slurry With Grey Cement And Pigment To Match The Shade / Colour / Matrix Of Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:6) Complete All As Specified And Directed. Etc Complete All As Specified And Directed. , Material And Labour For Double Charged Vitrified Ceramic Tiles Light Shade 9 To 10Mm Thick (Square/Rectangular) Area Of Each Tile Not Exceeding 0.36 Sqm, Laid In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed In Cm 1:6 Complete All As Specified And As Directed. , Material And Labour For Double Charge Vitrified Ceramic Tiles, Light Shade, 9 To 10Mm Thick (Square/Rectangular) Area Of Each Tile Not Exceeding 0.36 Sqm,, In Skriting Dado Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Colour Of Tiles, Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed. , Material And Labour Non Skid Coloured Ceramic Tiles 7 To 8Mm Thick, (Square/Rectangular) Area Of Each Tiles Exc 0.06 Sqm But Not Exc 0.11 Sqm As In Floors Set And Jointed In Cement Slurry And Pointed In White Cement Mixed With Colour Pigment To Match Existing Surfaces With 15 Mm Thick Screed Bed In Cement Mortar (1:6) Including Dismantling Of Old Unserviceable Tiles Complete All As Specified And Directed. , Material And Labour For Glazed Light Coloured/Printed Ceramic Tiles 450X300x7mm Thick In Vertical Surfaces Such As Skirting, Dado Etc Set And Jointed In Neat Cement Slurry, Pointed In White Or Coloured Cement To Match Colour Of Tiles, Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed. , Material And Labour For Non Skid Ceramic Coloured Tiles 7 To 8Mm Thick (Square / Rectangular) Area Of Each Tiles Exc 0.18 Sqm But Not Exceeding 0.38 Sqm In Floor Etc Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match With Coloured Tiles Over 15Mm Thick Screed Bed In Cement Mortar 1:6 Complete All As Specified And Directed. , Material And Labour For Non Skid Ceramic Coloured Tiles 7 To 8Mm Thick (Square / Rectangular )Area Of Each Tiles Exc 0.18 Sqm But Not Exceeding 0.38 Sqm On Vertical Surfaces As Skirting Etc Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match With Coloured Tiles Over 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For 100Mm Thick Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate ) As.In Floor Finishing Even And Smooth With Out Using Extra Cement Complete All As Specified And As Directed , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Supply Only Water Proofing Compound. , Material And Labour For Rendering 15 Mm Thick In Cm (1:4) On Fair Faces Of Brick Work Or Concrete Surface Finsihed Even And Smooth (Without Using Extra Cement) Etc Complete All As Specified And As Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Make: Berger Weathercoat Anti Dustt Or Equivalent Of Asian Paint Or Nerolac) Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Supply And Fix Sheet Glass 4.0 Mm Thick Ordinary Quality And Glazing With Oil Putty/ Wooden Beads/ Aluminium Window In Squares Not Exc. 1.00 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For Preparation Of New Or Previously Untreated Surface Of Wood Or Wood Based Materials Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer All As Specified. , Material And Labour For Preparation Of New Steel And Iron Surfaces Of Any Description, Over 10 Cm In Width Or Girth , Not Otherwise Described And Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Etc Complete All As Specified And As Directed , Supply Hoisting And Fix 500 Ltrs Rotational Moulded Polythene Water Storage Water Tanks Twin Layered Construction ( Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Duly Isi Marked, 20Mm Gi Light Grade Over Flow Pipe Approx Length 1.5M Long, 20Mm Gi Medium Grade Pipe For Wash Out Approx Length 2.00 M Duly Plugged At One End Shall Be Provided Including Dismantling The Existing Tank Complete All As Specified. , Supply Hoisting And Fix 1000 Ltrs Rotational Moulded Polythene Water Storage Water Tanks Twin Layered Construction ( Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Duly Isi Marked, 20Mm Gi Light Grade Over Flow Pipe Approx Length 1.5M Long, 20Mm Gi Medium Grade Pipe For Wash Out Approx Length 2.00 M Duly Plugged At One End Shall Be Provided Including Dismantling The Existing Tank Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
6.
Defence #11392755 Technical Bid
Tender for Material And Labour For Plain Cement Concrete 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundation ,Filling And Mass Concrete Complete All As Specified And Directed . , Material And Labour For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc , Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C-1 Using (20Mm Graded Stone Aggregate) As In Bed Blocks For Hold Fast,Coping Errection Of Posts Etc Complete All As Specified And Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) On Slabs Supported On Walls , Beams And Columns In Floors , Roofs,Landings,Balconies, Canopies Deck Slabs, And In Shelves And The Like Complete All As Specified And As Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) Chajja, Facia Etc And The Like Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C0 (Using 12.5Mm Graded Stone Aggregate) As In Filling The Hollow Portion Of Steel Frame Complete All As Specified And Directed. , Supply Only Water Proofing Compound. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specifed And Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour For Form Work On Flat Sides To Soffits Of Suspended Roof Slabs Not Exc 200 Mm Thick (Horizontal Or Sloping), Walls , Beams And Columns In Floors,Landings,Balconies, Canopies Deck Slabs, And In Shelves Rough Finished Surface Of Concrete All As Specified And As Directed. , Material And Labour For Form Work On Flat Sides To Chajja, Fins, Louvers, Fascia Etc Rough Finished Surface Of Concrete All As Specified And As Directed. , Refixing Wooden Or Aluminium Door Shutters Of Any Description Exceeding 1 Sqm But Not Exceeding 2 Sqm Each In The Same Opening After Taking Down, Easing And Adjusting Including Refixing Builders Hardware, Glass Etc As Required And Renewal Of Unserviceable Screws Concrete All As Specified And As Directed. , Supply And Fix For 2Nd Class Hardwood Plain, Solid, Straight Chowkhats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue, Pinned At Joints Complete All As Specified And Directed. , Supply And Fix Factory Made 30 Mm Thick Flush Shutter Solid Core Construction With Block Board Core & Plywood Face Panels Commercial Type On Both Sides Incl 5Mm Thick Teakwood Leaping Alround Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Factory Made Door, 35 Mm Thick, Glazed And Skeleton Shutters, Open Rebated And Prepated To Receive Glass Gauze Etc (With Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Materials And Revated Sash Bars Any Number , Edges Of Framing Plain Chemfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass In Door Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (A) Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Glazed And Skeleton Window Shutter 30Mm Thick, Divided Into Squares, With Plain, Chamfered Or Rounded, Mitred And Rebated Sash Bars, Any Numbers, To Receive Glass, Gauze, Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (B) Complete All As Specified And Directed. , Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Stapple Etc Concrete All As Specified And As Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised , Plate Type ,Stove Enameled Black , With Bright Bolt Not Less Than 12Mm Dia With And Incl Minimum Of 6 Bolts And Nuts ,Four On Bolt Plate And Two On Staple Concrete All As Specified And As Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 100Mm Etc Complete All As Specified And Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 75Mm Etc Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 150 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 100 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 200 Mm Long Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 150 Mm Long Complete All As Specified And Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised Sliding Door Bolts , With Hasp Staple (Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast-Aluminium Ally Complete All As Specified And Directed. , Supply And Fix Powder Coated Three Track Aluminium Sliding Window With Approved Make Of Following Extruded Section Of Anodised Glazed Shutter As Per Standard Engineering Practices Including All Other Accessories Complete Including 4.00 Mm Thick Tinted Glass Panes, Rubber Beading, Mosquito Proofing, Locking System Etc. Complete All As Specified And As Directed. (Refer Jindal Cat M-2014 ) Aluminium Sections : A Series (I) Shutter Bottom & Top :- 37.50 X 15 X 1.3 Mm Thick (20690) (Ii) Shutter Interlock :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iii) Shutter Side (Handle) :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iv) Frame Bottom :- 75 X 26 X 1 Mm Thick (20671) (V) Frame Top And Sides :- 75 X 26 X 1 Mm Thick (20672) , Supply And Fix Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) Or Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/Neoprene Gasket Required (Fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Material And Labour Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.,Complete All As Specified And Directed. , Material And Labour For Mild Steel Conforming To Fe 410-0 Or Fe 310-0 In Framed Work Such As Grills, Gratings, Etc With Ends Of Bars Shouldered And/Or Riveted Or Forged Into Spikes; Framed Guard Bars; Ladders; Railings And Similar Work Complete All As Specified And Directed. , Supply And Fix Box Type Steel Windows With Side Hung Shutters Both Mosquito Proof And Glazed Shutter Including Projecting Type Hinges With Steel Handle And Steel Peg Stay With Glazing Bars And 12 Mm Square Bar Or Ground Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And As Directed. , Supply And Fix Steel Ventilators With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. , Material And Labour For Mild Steel Tmt Bars 10 Mm Dia And Over Cut To Length, Bent To Shape As Required Including Cranking, Bending And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia As In Reinforcement Bar Complete All As Specified And As Directed. , Repairing Of Existing Mild Steel Rolling Shutter Of Any Description Or Any Size Including Replacement Of Damaged Mild Steel Laths, Repairing/ Replacement Of Side Guide Channels, Pipe Shaft, Springs, Ball Bearings, Locking Arrangements, Welding Work, Alingment And Smooth Operation, Including Necessary Nuts, Bolts, Oiling And Greasing, Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Atmospheric Classification Category 3,Four (4) Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed , Material And Labour For Pre- Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Plain Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Pattern Corresponding To Is 15965 : 2012 Of Durability Class 3, Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Having Yield Strength Of 550 Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified Complete All As Specified And As Directed. Note: To Be Executed For Provision Of Ridges And Hips. , Material And Labour For 12 Mm Thick Prelaminated Particle Board Bwp Type Melamine Finished (Both Side) For Fixing The Panel Of The Partition/Door Including Necessary Fittings, Gusket, Angle Cleats, Screw Etc Complete All As Specified And Directed. , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour For Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:4) Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm Thick, In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8Mm Thick Area Of Each Tile Exceeding 0.18 And N.Exc 0.38 Sqm In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exc 0.18 And N.Exc 0.38 Sqm , In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. , Material And Labour For Coloured/ Printed Glazed Ceramic Tiles 7Mm Thick Not Exc 0.15 Sqm In Area In Vertical Surfaces I.E. Dado, Skirting, Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, Laid Over And Including Screed Or Screed Bed 10Mm Thick In Cement Mortar 1:4, Complete All As Specified And As Directed. , Material And Labour For 75Mm Thick Cement Concrete 1:3:6 Type C-2 (Using 40Mm Graded Stone Aggregate ) As In Plinth Protection Complete All As Specified And Directed. , Material And Labour For 100Mm Thick Cement Concrete 1:2:4 Type B-2 (Using 40Mm Graded Stone Aggregate) As In Flooring, Hardstanding Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Material And Labour For 5Mm Thick Rendering On Fair Faces Of Brick Or Concrete Surface In Cm 1:3 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Ceiling Surface And Applying Three Coats Of White Wash Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Figured Glass, Pin Head Type And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For Preparation And Applying Two Coats Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Over A Coat Of Pink Primer Complete All As Specified And Directed. , Material And Labour For Preparation Of Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide On New Steel Surfaces , Over 10 Cm In Width Or Grith Not Other Wise Described Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 15Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 20 Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Hand Basin White, Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Pvc Waste Coupling And 32 Mm Dia Pvc Waste Pipe Including Fixing Of Tap, Waste Fitting Etc Complete All As Specified And Directed. , Supply And Fix In Repair Bib Taps With Wall Flange 15Mm Bore, Fancy Type, Quarter/Half Turn, Brass Chromium Plated, Long Body With Capstan Head And Cup Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Accessories Complete All As Specified And Directed. , Supply And Fix In Repair 125 Mm Dia, Chromium Plated Swivel Type Shower Rose With 195 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15Mm Bore Iron Pipe All As Specified And Directed , Supply And Fix In Repair Bath Wall Mixer With 15Mm Bore (Dia) Spout, Chromium Plated With Long Bend Pipe For Over Head Shower Including Flanges Complete All As Specified And As Directed. , Supply And Fix In Repair Pillar Taps, Cast Copper Alloy, With Capstan Heads, Fancy Type, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered ‘Hot Or ‘Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe 15 Mm Bore Complete All As Specified And Directed. , Supply And Fix In Repair Cp Stop Valve/Angle Valve 15 Mm Bore, Fancy Type Cromimum Plated With Long Shank And Cup (Concealed Type), High Pressure Crutch Or Butter Fly Handle Screwed Both Ends Screwed For Iron Pipe Or For Unions Complete All As Specified And Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 1000 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places With Fittings And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 500 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places Complete And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix Ball Valves 20Mm Bore Dia Of Pipe High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed (Minimum Weight 20Mm-210Gms). , Supply And Fix In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Supply And Fix In Repair Pvc Valve, Symphonic Action Type, Flushing Cistern 10 Liters Capacity Low Level White With Inlet ,Ball Valve ,Float And Handle Including Brocket Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Pvc (Swr) Pipes, Presure Rate Having 6 Kgf Single Socketed In Any Length With Rubber Ring Joints And Laid In Trenches As In Waste/Soil Pipe Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Complete All As Specified And As Directed. , Supply And Fix 75Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Or Floor Complete All As Specified And As Directed. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 75 Mm Bore Complete. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 110 Mm Bore Complete. , Supply And Fix, In Repair Vitreous China Wash Down Water Closet Of Orissa Pattern Size 580 X 440 Mm White With Integral Foot Rests Including Removing Filled Lean Concrete From Sunken Portion And Putting Of Lean Concrete After Treatment Of Sunken Slab, Connection To Trap And To Flushing Pipe Etc Complete And Making Good To Floor Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Down Water Closed Pan (Pedestal Pattern) With P Or S Trap White, Including Connection To Trap And Cistern, Flush Pipe Including White Plastic Water Closet Seat Cover, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Making Good Disturbed Surface Of Floor Complete All As Specified And Directed. , Supply And Fix In Repair Plastic Water Closet Seat Cover, White, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Fixed Wc Pan Complete All As Specified And Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Down Door Chowkhat With Shutter Area N-Exc 1.5 Sqm Each(Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Chowkhats Or Frames With Shutters Exc 1.5 Sqm But Not Exc 4 Sqm Each (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Of Any Description N. Exc 1 Sqm Each Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Any Description Area Exc 1 Sqm And N Exc 2 Sqm Each Complete All As Specified And Directed. , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete (Reinforcement Cut As Required To Facilitate Demolition) Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And As Directed. , Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Or Cement Lime Mortar , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Trusses Etc Complete All As Specified. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc. , Dismantling, Floor Hearth Or Wall Tiling Inclduing Cement Mortar Bedding And Removing Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc. 15 Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , Demolition And Breaking Up Drain Waste Pipes (Sgsw, Ac Or Rcc, Ci ) Of Internal Dia 75/110 Mm, Set In Cement Mortar In Any Position Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
7.
Petroleum and Natural Gas #11347460 AOC
Bids Are Invited For 20.25.99.962.5 Bearing Shell For Exciter Bhel Gt1 , 20.25.99.963.5 Sealing Ring F Exciter Bearing Bhel Gt1 , 20.25.99.964.5 Bearing Insulation Bhel Gt1 , 20.25.99.965.5 Rtd For Exciter Bearing Bhel Gt1 , 20.25.99.966.5 Rc Block Bhel Gt1 , 20.25.99.967.5 Positive Diode Bhel Gt1 , 20.25.99.968.5 Negative Diode Bhel Gt1 , 20.25.99.969.5 Fuse Bhel Gt1 , 20.25.99.970.5 Heat Sink Type I Bhel Gt1 , 20.25.99.971.5 Heat Sink Type Ii Bhel Gt1 , 20.25.99.948.5 Generator Bearing Shell Bhel Gt1 , 20.25.99.949.5 Bearing Labyrinth Rings Bhel Gt1 , 20.25.99.950.5 Sealing Ring For Brg Pedestal Bhel Gt1 , 20.25.99.951.5 Scrapper Fin For Sealing Ring Bhel Gt1 , 20.25.99.952.5 Gt Bearing And Oil Line Insulation Bhel Gt1 , 20.25.99.953.5 Gr Shaft Earthing Brush A Bhel Gt1 , 20.25.99.954.5 Gr Shaft Earthing Brush B Bhel Gt1 , 20.25.99.955.5 Brush Holder For Shaft Earthing Bhel Gt1 , 20.25.99.956.5 Space Heater Bhel Gt1 , 20.25.99.957.5 Rtd For Generator Brg Bhel Gt1 , 20.25.99.958.5 Rtd For Hot Cold Air Bhel Gt1 , 20.25.99.959.5 Fire Detector 100Degc Bhel Gt1 , 20.25.99.960.5 Fire Detector 80Degc Bhel Gt1 , 20.25.99.961.5 Coupling Fasteners Bhel Gt1 , 20.25.99.938.5 Bearing Shell For Exciter Gt2 , 20.25.99.939.5 Sealing Ring For Exciter Bearing Gt2 , 20.25.99.940.5 Exciter Bearing Insulation Gt2 , 20.25.99.941.5 Rtd For Exciter Bearing Gt2 , 20.25.99.942.5 Rc Block Gt2 , 20.25.99.943.5 Positive Diode Gt2 , 20.25.99.944.5 Negative Diode Gt2 , 20.25.99.945.5 Fuse Gt2 , 20.25.99.946.5 Heat Sink Type I Gt2 , 20.25.99.947.5 Heat Sink Type Ii Gt2 , 20.25.99.924.5 Generator Brg Shell Tari 700 28P Gt2 , 20.25.99.925.5 Brg Labyrinth Ring Bhel Tari 700 28P Gt2 , 20.25.99.926.5 Sealing Ring Bhel Tari 700 28P Gt2 , 20.25.99.927.5 Scrapper Fin Bhel Tari 700 28P Gt2 , 20.25.99.928.5 Gt Bearing And Oil Line Insulation Gt2 , 20.25.99.929.5 Generator Shaft Earthing Brush A Gt2 , 20.25.99.930.5 Generator Shaft Earthing Brush B Gt2 , 20.25.99.931.5 Brush Holder For Shaft Earthing Gt2 , 20.25.99.932.5 Space Heater Gt2 , 20.25.99.933.5 Rtd For Generator Bearing Gt2 , 20.25.99.934.5 Rtd For Hot Cold Air Gt2 , 20.25.99.935.5 Fire Detector 100Degc Gt2 , 20.25.99.936.5 Fire Detector 80Degc Gt2 , 20.25.99.937.5 Coupling Fasteners Gt2 Total Quantity : 222
Contract Date: Ref. Documents Contract Value : 4.45 Crore
Boards / Undertakings / PSU No of Bidders 1
Maharashtra View Result →
10.
Defence #11329394 AOC
Bid Are Invited For 1 Pvc Pendent Holder. 2 One Way. Bed Switch. 3 Single Pole 10 Amps, Two Way Switch, Isi Marked. Modular Type. 4 Modular Bell Push Switch. 5 Modular Blanking Plate. 6 Single Pole 25 Amps, One Way Modular Switch, Isi Marked. 7 2 Module, Modular Base And Cover Plate. 8 3 Module, Modular Base And Cover Plate. 9 4 Module, Modular Base And Cover Plate. 10 6 Module, Modular Base And Cover Plate. 11 12 Module, Modular Base And Cover Plate. 12 Flame Retardant, Pvc Electrical Insulation Tapes 6 Mtr X 1.8 Cm Long. 13 Pvc Gitt, Pvc Rawal Plug, Pvc Fastener 38 To 40Mm Long. 14 3 Mm Thick Phenolic Laminated Sheet. 15 1.5 Sq. Mm. Frls Or Hffr Single Core, Multi Strand Copper Conductor, Pvc Insulated Cable Suitable Upto 1100 Volts. 16 4.0 Sq. Mm. Frls Or Hffr Single Core, Multi Strand Copper Conductor, Pvc Insulated Cable Suitable Upto 1100 Volts. 17 6.0 Sq. Mm. Frls Or Hffr Single Core, Multi Strand Copper Conductor, Pvc Insulated Cable Suitable Upto 1100 Volts. 18 Modular Mcb Single Pole 25 Amp C Curve, 3 Ka Breaking Capacity. 19 Pin Anchor Fastener 6 X 50 20 Pin Anchor Fastener 8 X 50 21 Pin Anchor Fastener 8 X 75 22 Pin Anchor Fastener 10 X 100 23 Ring Hook Fastener M-8 24 Ring Hook Fastener M-10 25 Wedge Anchor Fastener 8 Mm X 75 Mm 26 3 Mm Thick Pvc Or Phenolic Laminated Round Sheet Cover Minimum170 Mm Dia For Fan Box. 27 3 Mm Thick Pvc Or Phenolic Laminated Round Sheet Cover 100 Mm Dia. 28 3 Module , Pvc Surface Modular Box For Following Module. 29 6 Module , Pvc Surface Modular Box For Following Module. 30 Bee 5 Star Rating, 25 Litres Capacity Water Storage Heater, With Protection Against Over Heating, Multifunction Safety Valve And External Adjustable Thermostat. 31 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current Motor. 32 Supply Of 400 Mm, Single Phase Wall Mounting Fan. 33 Fresh Air Fan With Louver Shutter 250 Mm Sweep. 34 230 Mm Sweep, 1400 Rpm , Single Phase, Metallic Exhaust Fan Conforming To Is 2312 -1967. 35 Metallic Louvred Shutter Suitable For 300 Mm Sizes Exhaust Fan. 36 Metallic Louvred Shutter Suitable For 380 Mm Sizes Exhaust Fan. 37 18- 22 Watt Led Surface Mounted Batten Light. 38 40 Watt Led Surface Mounted Batten Light. 39 5-7 Watt Led Recessed Orsurface Down Lighter. 40 12 -15 Watt Led Recessed Or Surface Down Lighter. 41 18 Watt Led Recessed Or Surface Down Lighter. 42 Led Batten Emergency ,Inverter, Luminaire Minimum System Lumen Output Of 2000 Lumen. 43 Utility Knife Tapaia Uk-3 44 Spare Blade Ub-10 For Utility Knife Uk-3 Taparia 45 Flexible Connection Pipe 450Mm Long, Metal Braided Hoses . 46 Measuring Tape, Length Of The Tape Is 30 M. The Width Of The Blade Is 13Mm. 47 Casing Capping Clip 48 Pvc Nail Clip 20 Mm Double Nail. 49 Aluminium Paint . 50 Red Oxide Metal Primer. 51 Paint Thinner. 52 Paint Brush 2 Inch 53 Paint Brush 3 Inch 54 Wooden Screw 35 X 8 55 Wooden Screw 50 X 8 56 Dry Wall Gypsum Screw 0.75 Inch 57 Dry Wall Gypsum Screw 1Inch 58 Dry Wall Gypsum Screw 1.5 Inch 59 10 Amp, 12 Way, Pvc Strip Connector. 60 15 Amp, 12 Way, Pvc Strip Connector. 61 Iron Drill Bit Set Having 25 Pcs . 62 Self Supported Frp Platform Step Ladder 63 Multifunction Testers . 64 400 Amp 04 Pole Power Contactor. 65 16 Sq Mm Aluminium Flat Thimble 66 25 Sq Mm Aluminium Flat Thimble 67 50 Sq Mm Aluminium Flat Thimble 68 70 Sq Mm Aluminium Flat Thimble 69 95 Sq Mm Aluminium Flat Thimble 70 120 Sq Mm Aluminium Flat Thimble 71 150 Sqmm Aluminium Flat Thimble 72 185 Sq Mm Aluminium Flat Thimble 73 240 Sq Mm Aluminium Flat Thimble 74 300 Sq Mm Aluminium Flat Thimble 75 400 Sq Mm Aluminium Flat Thimble 76 16 Sq Mm Aluminium Ferrule 77 25 Sq Mm Aluminium Ferrule 78 35 Sq Mm Aluminium Ferrule 79 50 Sq Mm Aluminium Ferrule 80 70 Sq Mm Aluminium Ferrule 81 70 Watt Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Driver . 82 150 Watt Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Driver. 83 45 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver . 84 72 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver. 85 90 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver. 86 150 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver As Per The Requirement With Driver. 87 10 To 11 Watt, 0.6 Metre Nominal Size Led Bollard Light Fitting Complete With Led Module. 88 25-Watt Led-Based Post-Top Luminaire, Ip 65, With Die-Cast Aluminium Spigot Housing, Complete With Diffuser, Led Module, Driver With Surge Protection . 89 10 Watt To 12 Watt Spike Led Light With Aluminium Housing, Ip66 Having Tiltable Feature To Throw Light In The Desired Direction. 90 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 2 X 16 Sq. Mm Sq. Mm 1.1 Kv Grade Cable. 91 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 2 X 25 Sq. Mm Sq. Mm 1.1 Kv Grade Cable. 92 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 3.5 X 35 Sq. Mm Sq. Mm 1.1 Kv Grade Cable. 93 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 3.5 X 300 Sq. Mm 1.1 Kv Grade Cable. 94 Cable Junction Boxes, Ip 66 Weather Proof, Size 205 Mm X 255 Mm X 112 Mm, With Terminals Suitable For 16 Sq Mm Cable. 95 4 Inch Cutting Wheel For Metal Suitable For 4 Inch Angle Grinder. 96 1.5 Volt Alkaline Non-Rechargeable, Type Battery, Size- Aaa. 97 1.5 Volt Alkaline Non-Rechargeable, Type Battery, Size- Aa. 98 9 Volts Alkaline Non-Rechargeable Battery. 99 23A, 12V Alkaline Battery. 100 Led Rope Light, 10 Watt Per Metre Or 120 Led Per Metre, In Various Colors, Ip65 Rating, With Adopter. 101 Supplying Of Adapter For Led Rope Light. 102 Led Rope Light, 6 W Per Mtr, Ip65, Tri-Color. 18 Meter. 103 Supplying Pidilite Wd 40 Mechinical Contact Cleaner In 500 Ml Can With Straw Spray. 104 2 X 16 Sq Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is 7098 Part 1 1988 With Upto Date Amendments. 105 2 X 25 Sq Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is 7098 Part 1 1988 With Upto Date Amendments. 106 3.5 X 35 Sq. Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade, Confirming To Is 7098 Part 1 1988 With Up To Date Amendments. 107 3.5 X 120 Sq. Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade, Confirming To Is 7098 Part 1 1988 With Up To Date Amendments. 108 3.5 X 400 Sq. Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade, Confirming To Is 7098 Part 1 1988 With Up To Date Amendments. 109 Socket Tester To Verify That The Wall Socket Is Correctly Wired And To Check For Common Faults. 110 M-Seal - Regular Epoxy Compound. 111 Pu Foam Insulation Sealant 750 Ml 112 Distilled Water, 5 Liters . 113 Weatherproof, Ip66, Wire Connector With Plug And Socket Suitable For 4 Sq Mm Copper Cable. 114 Digital Earth Resistancetester. 115 Pvc Weatherproof, Ip65, 8 Module Mcb Db With Din Rail. 116 Wall-Mounted Voltage Stabilizer, Suitable For 1.5 Ton Split Air Conditioner. 117 Wall-Mounted Voltage Stabilizer, Suitable For 2 Ton Split Air Conditioner. 118 Blue Plastic Crate, 4 Litre Capacity, Size 300 X 200 X 100 Mm, Suitable For Material Storage. 119 Pvc Weatherproof Switch Box, Ip66 Rated. 120 A Power Adaptor With In Built Rcd 30 Ma 121 Robustt Caution Tape 3 Inches X 130 Mt, Pack Of 1, White And Red Pvc Material, Barrication Tape. 122 Polypropylene Floor Standing Caution Sign Board 123 Stainless Steel Clip For Fixing Led Batten As Per Sample Provided By Department. 124 Waterproof Paint Marke. 125 15A Insulated Test Lead Cable With Dual-Ended Insulated Crocodile Clips, Suitable For Electrical Testing. Set Of 5 Pc. 126 Plastic Step Stool, Nominal Dimensions Width 57 Cm, Depth 54 Cm, Height 60 Cm. 127 30W 220V Round Corded Soldering Iron With Led Worklight . 6 Months Warranty. 128 Solder Paste Flux Pack -50 Gm 129 Lead-Free Soldering Wire, 0.8 Mm Diameter, Suitable For Electronic And Electrical Soldering And Component Repair. 20-Gram Pack. 130 Cleaning Cloth Towels, Material 100 Percent Cotton. 131 Microfiber Multi-Purpose Cleaning Wipe. 132 Contactless Surface Temperature Detector. 133 Pvc Plastic Pipe Cutter, Cutting Capacity Up To 42 Mm 134 Hss Bi-Metal Holesaw Set, 20 To 64 Mm Diameter Hole Saw Sizes 20, 25, 32, 38, 51, And 64 Mm. 135 Plastic Tool Box With Organizer, Height 150 Mm, Width 190 Mm, Length 335 Mm 136 High Carbon Steel Shovel With Wooden Handle. 137 Hoe Powrahs 138 High Tempered Iron Pickaxe 139 Aluminium Self Supporting Type Tower Ladder Extendable
Contract Date: Ref. Documents Contract Value : 44.45 Lakh
Government Departments No of Bidders 6
13.
Educational and Research Institute #11305964 Price Bid
Tender for Equipment For Electronic Device & Circuit Lab And Vlsi Lab , Price Schedule For Vlsi Lab (Sheet 1) , Price Schedule For Electronic Device Circuit Lab (Sheet 2) , Price Schedule For Services (Sheet 3) , Cadence University Standard Bundle Design Systems Software (15 Users, 5 Years License) , Analog And Digital Signal Analyzer For Testing And Debugging Of High Frequency Analog, Digital & Rf Circuits , Precision Weighing Balance , Lcr Meter , Desktop Computer , Circuit Design And Simulation Bundle [10 User] , Fpga Trainer Kit , Edge Spartan 6 Fpga Development Board , Fpga Development Board (410-292) , Fpga Development Board(35T) , Cpld Development Learning Board , Arm/Fpga Soc Development Board , Stmicroelectronics Nucleo-H7a3zi-Q Development Board , Stmicroelectronics Nucleo-L010rb Development Board , Altera De2-115 Development And Education Board , Basys-3 Fpga Board , Advance Spartan-6 Fpga Platform For Vlsi Lab , Central Server To Install Licensed Softwares , Digital Storage Osciloscope , Function Generator , Dc Regulated Power Supply , Digital Multimeter , Lcq Meter , Heat Gun , Bread Board , Soldering Station , Step Down Transformer , R/L/C Components , Cutters , Wires , All Analog Digital Ics , Transistors , Diodes (Normal-Pn ,Zener, Photodiodes,Tunnel Diodes, Bridge-Recti , Leds (Red, Green, Yellow) , Desoldering Pump , Magnifing Glass With Light Stand , Phase Sequence Indicator , Heat Sinks , Lcr Meter , Potentiometers , Power Amplifiers , Simulation Software (Multisim: 50 Circuit Components, Simulation, Design , Digital Trainer Kit/Electronic Component Development System , Logic Probe , Screw Driver Set , Oscillator Kit , Op-Amp Kit , Pid Controllers , Data Acquisition Systems (Daq) , Dc Motor Kits , Stepper Motors , Servo Motors , Programmable Logic Controllers (Plc) , Sensors (E.G., Temperature, Pressure, Position) , Actuators (E.G., Solenoids, Relays) , Potentiometer Error Detector Kit , Light Intensity Control System Kit , Speed-Torque Character
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
14.
Civil Aviation #11297332 AOC
Bids Are invited for Annual Maintenance Contract of Fire Hydrant including all pumps, panels, cables, piping , Hydrants etc. , intelligent type analogue addressable Fire Alarm system and Sprinkler system including all pumps, panels, cables, piping, sprinklers etc. at Aurangabad Airport for all preventive maintenance and checks as per manufacturers manual including attending to complaints/ Faults/ break down and taking rectification action, ensuring serviceability/ satisfactory working conditions of the system, maintenance of all records, documentation etc. as per the detailed specifications, terms & conditions covered under this contract on all days including sundays and holidays as per requirements of AAI. , Annual maintenance contract of Kirloskar make DG pump set (with specification mentioned under (A)) i/c engine control panel and other accessories of DG pump set.Job includes monthly visits for carrying out preventive maintenance, attending any number of breakdown calls when required, carrying out B and C check, minor repairs etc. as per manufacturers recommendations / standard practice and as per the scope of work, complete as required. A) Engine type - 6R1080, Rating - 79 hp, RPM - 1500, governing class - M2. , Supplying, installation, testing & commissioning of Conventional Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of addressable Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required. (Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of Conventional Multi Sensor detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors) , Supplying, installation, testing & commissioning of conventional manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc.complying to relevant IS etc. as required.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. complying to relevant IS etc. as required. (Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional fire alarm panel , 16 X 2 dotmatrix LCD display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all otherstandard facilities as per IS:2189, complying relevant national fire alarm code for local fire alarm system with mimic diagram for allarea/zone covered, complete with all connections. The panel shall have input of 240 volts AC power supply, automatic battery charger, 24 volts, 2 X 12 volts, 12 Ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. The panel shall be UL listed & FM approved and shall be hookup with PA system and along with auto dialer facility etc. as required. (Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supply, Installation, Testing & Commissioning of UL / EN listed (latest version) Modular Microprocessor based expandable intellegent Addressable Type Fire Alarm Control Panel of following loops, with minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intellegent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling ventilation fan, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 230 volts, 50 Hz AC power supply, automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and then be capable of operating the system for 30 minutes during an emergency / fault conditions along with battery stand as required. The panel shall have facility for seamless integration with PA system (For Giving triger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). The panel shall be compatible for Building Management System with open protocol BACNET / MODBUS etc. as per specification, complete as required.(Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required.(Approved Makes : CMI/ KEI/ BONTON/ POLYCAB/BATRA HENLAY/ RR CABLE/ WAREXHAM). , Supply of 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with necessary male and female gun metal / SS couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , Supply of standard short sized branch pipe constructed from SS material of 63mm dia.and be complete with male instantaneous spring lock type coupling for connection to the end of hose pipe,Externally threaded to receive nozzle,conforming to IS:903 etc. complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , supply of nozzle,20mm inner diamter,made of SS,screw threads at the inlet connection to match with the threading of 63mm dia branch pipe with inlet end of hexagonal head to facilitate screwing conforming to IS 903 etc. as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).
Contract Date: Ref. Documents Contract Value : 13.35 Lakh
Boards / Undertakings / PSU No of Bidders 11
Daman and Diu View Result →
15.
Educational and Research Institute #11294681 Technical Bid
Tender for Purchase Of Trainer Kits And Function Generator , Trainer Kits And Function Generator , Function Generator Frequency Range : 0.11 Hz To 3.33 Mhz Waveforms: Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Duty Cycle Control And Variable Dc Offset Control -20Db * 2 And Variable Attenuator. Waveform Types Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Ttl Output Range 4Vpp - 20Vpp 4.8Vpp Sine Wave Distortion 0.11 Hz-100: Max 0.5 % 0.1 Mhz - 0.3 Mhz Max 1.5% 0.3 Mhz - 3Mhz Max 3% Square Wave Rise /Fall Time Overshoot Duty Cycle ≤ 60Ns ≤ 7.5% 50% Pulse Wave Pulsewidth Range Rise /Fall Time 15 % To 85 % ≤ 60Ns Ttl Output Level Amplitude Fan-Out Rise /Fall Time ≥4.8Vpp 10Ttl Load ≤ 60Ns The Display Shows Function And Frequency On The 16*2 Lcd Display Amplitude We Get From 1.5 V Pp To 20 V Pp And Varies As Per The Different Frequency Range Amplitude Distortion Without Load Wave 1 Mhz 2Mhz Sin 20 Vpp 18 Vpp Square 20 Vpp 20 Vpp Triangle 20 Vpp 16 Vpp Pulses 20 Vpp 18 Vpp Ttl 5 Vpp 5 Vpp Dc Varies From 0 ± 5V Dc Function Generator Frequency Range : 0.11 Hz To 3.33 Mhz Waveforms: Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Duty Cycle Control And Variable Dc Offset Control -20Db * 2 And Variable Attenuator. Waveform Types Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Ttl Output Range 4Vpp - 20Vpp 4.8Vpp Sine Wave Distortion 0.11 Hz-100: Max 0.5 % 0.1 Mhz - 0.3 Mhz Max 1.5% 0.3 Mhz - 3Mhz Max 3% Square Wave Rise /Fall Time Overshoot Duty Cycle ≤ 60Ns ≤ 7.5% 50% Pulse Wave Pulsewidth Range Rise /Fall Time 15 % To 85 % ≤ 60Ns Ttl Output Level Amplitude Fan-Out Rise /Fall Time ≥4.8Vpp 10Ttl Load ≤ 60Ns The Display Shows Function And Frequency On The 16*2 Lcd Display Amplitude We Get From 1.5 V Pp To 20 V Pp And Varies As Per The Different Frequency Range Amplitude Distortion Without Load Wave 1 Mhz 2Mhz Sin 20 Vpp 18 Vpp Square 20 Vpp 20 Vpp Triangle 20 Vpp 16 Vpp Pulses 20 Vpp 18 Vpp Ttl 5 Vpp 5 Vpp Dc Varies From 0 ± 5V Dc 1. Equipped With 16 High-Visibility Leds For Monitoring Experimental Outputs And Logic Status Indication. 2. Dedicated Driver Circuitry Provided For Reliable Operation And Protection Of All 16 Leds During Experimentation. 3. All 16 Driver Input Lines Are Terminated Through Banana Connectors For Flexible And Easy External Interfacing. 4. Includes 16 Spdt Toggle Switches For Generating Manual Logic Input Conditions In Digital Electronics Experiments. 5. Additional 16 Leds Provided To Display The Real-Time Status Of Individual Switch Operations. 6. One Terminal Of Each Spdt Switch Is Externally Accessible Through Banana Sockets For Convenient Circuit Connections. 7. Built-In Variable Clock Generator Enables Pulse Generation For Sequential And Timing-Based 8. Digital Experiments. 9. Frequency Adjustment Provided Through Potentiometer And Rotary Switch Combination For Precise Clock Selection. 10. Clock Output Is Terminated Through Banana Connectors For Quick Integration With External Circuits And Trainer Modules. 11. Features Dual 7-Segment Led Display With 7447 Decoder/Driver Ic For Bcd To Display 12. Conversion Experiments. 13. Inputs Of The 7447 Drivers Are Terminated At Banana Connectors For Direct Digital Logic Interfacing. 14. Includes Solderless Breadboard For Rapid Circuit Prototyping And Reusable Experimental Setup Development. , Strain Gauge Study Trainer This Trainer Shall Consists Of Cantilever Jig And Strain Gauge Bonded On The Cantilever, A Signal Conditioner For The Strain Gauge, Instrumentation Power Supply, 3½ Digit Digital Indicator Display The Strain. * Cantilever Beam Of Maximum Weight Upto 1Kg. * A Pan With Slotted Weights To Vary The Strain. * Built In Instrumentation Power Supply * Signal Conditioning Card For The Strain Gauge * 3½ Digit Digital Display For Displaying The Strain * Offset And Gain Variable Provision * Logical Diagram With Panel. * Mounted In Sleek Cabinet. 1) On Board Carrier And Modulating Signal Generator With Amplitude And Frequency Adjustable 2) Carrier And Modulating Signals Are Provided In The Unit With Frequency Variable. 3) In-Built Regulated Power Supply 4) On Board Envelope Detector 5) Schematic Diagram Provided In The Front Panel Modulating Signal Frequency : (300Hz-3 Khz) Amplitude : (0-5) V Carrier Signal Carrier Signal Frequency : 10 Khz - 50 Khz Amplitude : (0-15) V Type Of Modulator : 1. Ring Modulator 2. Transistor Based Modulator Method Of Modulation : 1. Under Modulation 2. Critical Modulation 3. Over Modulation , Load Cell Study Trainer This Module Shall Consists Of A 5Kg Load Cell Sensor, Weights, Signal Conditioner And 3½ Digit Digital Indicators To Display The Load. * Strain Gauge Based Load Cell Sensor Of 5Kg Capacity * A Pan Provision For Placing The Standard Weights Signal Conditioner For Load Cell (Output 0-5V) * Built In Instrumentation Power Supply * Zero Calibration Provision. * 3½ Digit Digital Indicator To Display The Applied Load. * Mounted In A Elegant Powder Coated Cabinet With Mimic Diagram 1) On Board Sine Wave Generator 2) Provision To Study Modulation & Demodulation In The Same Unit 3) Test Points To Study Different Waveforms 4) In-Built Audio Power Amplifier 5) Mic Pre Amplifier 6) Built-In Power Supply 7) Sine Wave Generator : Frequency - 100Hz To 1.2 Khz With Amplitude Adjustable, (0-5V) 8) Fm Modulator : Direct Fm 9) Carrier Frequency : 20 Khz (Low), 367 Khz(High) 10) Fm Demodulator : Pll Detector, Quadrature Detector, Foster Seelay Discriminator / Phase Discriminator, Ratio Detector Are Provided. 11) Audio Power Amplifier : Gain 100 12) Mic Pre Amplifier : Gain 20 , Lvdt Study Trainer It Shall Consists Of A Lvdt Sensor, Signal Conditioner And A Digital Indicator To Display The Displacement Cantilever Jig With Micrometer. * Lvdt Sensor With Micrometer (Range: 0-25Mm) * Signal Conditioner For Lvdt * Displacement Calibrated Range From (-10Mm To + 10Mm) * Output Voltage (-5V To +5V) * Built In Instrumentation Power Supply * A 3½ Digit Digital Indicator To Display The Displacement * Mounted In A Elegant Powder Coated Cabinet. * Logical Diagram In The Panel Detailed Documentation , Thermistor Study Trainer  One Negative Temperature Co- Efficient Type Thermistor Sensor Is Used As A Temperature Sensor.  Signal Conditioner For Thermistor Transducer: Output 5-0V  Built In Instrumentation Power Supply  A 3½ Digit Digital Indicator Is Used For Voltage Display  Zero Calibration Provision  Water Bath Is Used As A Heat Source.  Thermometer Is Provided To Monitor The Actual Temperature.  Mounted In An Elegant Cabinet , Thermo Couple Study Trainer * One J Type Thermocouple Is Used As A Temperature Sensor * One Ad590 Sensor Is Used For Cold Junction Compensation * Signal Conditioner For J Type Thermocouple Output: (0-5V) * Built In Instrumentation Power Supply * 3½ Digit Digital Indicator To Display The Temperature. * Water Bath Is Used As A Heat Source * Zero Calibration Provision * Thermometer Provided To Monitor The Temperature * Mounted In A Elegant Powder Coated Cabinet * Logical Diagram In The Panel Detailed Documentation , Rtd Study Trainer * Pt100 Type Rtd Is Used As A Temperature Sensor * 3 Wire Configurations Is Provided Signal Conditioner For Rtd Output Is (0-5V) * Built-In Instrumentation Power Supply * A 3½ Digit Digital Indicator To Display The Temperature * Water Bath Is Used As A Heat Source. * Thermometer Provided To Monitor The Actual Temperature * Mounted In A Closed Cabinet. Detailed Documentation. , Piezo Electric Transducer Study Trainer This Trainer System Shall Consists Of Vibration / Acceleration Sensor Of Piezo Electric Type, Signal Conditioner, Regulated Power Supply, 3½ Digit Digital Indicator Etc Provided To Study The Characteristics Of Piezo Electric Sensor * Vibration Sensor Of Piezo Electric Type Mounted In The Base Plate To Sense The Vibration Of The Material. * Precision Rectifier Circuit For Above Sensor. * Signal Conditioner Of (0-10)Vdc * Ic Regulated Power Supply * 3½ Digit Digital Indicator To Display The Voltage. * Logical Diagram In The Panel * Mounted In A Powder Coated Closed Cabinet. Vibrator Exciter  One Mechanical Setup Provided  One Vibration Motor To Vibrate The Mechanical Setup # I/P : 230V Ac/50 Hz # Power : Max: 0.5 Hp One Auto Transformer Is To Vary The Input Voltage For Mechanical Setup , Schrings Bridge * 4 Arms With Suitable Connectors. * Provision To Connect The Unknown Capacitance At One Arm * Two Potentiometers Provided At Two Arms To Obtain The Bridge Balance Condition. * Input Of The Bridge Is Taken From A 1Khz Fixed Amplitude Oscillator. * One Audio Amplifier With Miniature Speaker Is Provided To Detect The Bridge Balance Condition Acoustically. * Measuring Range : 0.001Uf - 2.0Uf * Sensitivity : +0.1Uf * Tolerance : +5% * All Are Housed In A Metal Cabinet * Detailed Documentation * Required Patch Chords Are Provided Decade Capacitance Box Dial 1 :0-0.01Mfd In Steps Of 0.001Mfd Dial 2 :0-0.1Mfd In Steps Of 0.01Mfd Dial 3 :0-1Mfd In Steps Of 0.1Mfd Dial 4 :10Mfd In Steps Of 1Mfd Total Range : 0-11.11Mfd , Maxwells Inductance Bridge * Four Arms Are Provided With Suitable Connectors * One Arm With Provisions To Detect The Nearest Range Of Unknown Inductance. * Two Arms With Variable Potentiometers Given To Balance The Bridge In Null Condition * One 1 Khz Oscillator Of Fixed Amplitude To Feed The Input To The Bridge. * One Audio Amplifier With Speaker To Detect The Bridge Balancing Conditions. * Measurement Range: 15Mh - 200Mh * Tolerance : +5% * Built-In Power Supply * Connector Facility Given To View The Output Of The Bridge Externally By Cro * All Are Housed In A Powder-Coated Cabinet With Logical Diagram. * Required Patch Chords Are Provided Decade Inductance Box Dial 1 :0-9Mh In Steps Of 1Mh Dial 2 :0-90Mh In Steps Of 10Mh Dial 3 :0-900Mh In Steps Of 100Mh Total Range :0-999Mh , Voltmeter Desk Top Analog Voltmeter (0-1V Dc, 0-10V Dc, 0-30V Dc, 0-5V Dc) Each 5 Nos , Ammeter Desk Top Analog Ammeter (0-10Ma Dc, 0- 50Ma Dc, 0-100Ma Dc, 0-500Microa Dc) Each 5 Nos , Digital Trainer Kit * 16 LedS Are Provided To Indicate The Status/Outputs Of An Experiment. * Drivers Provided To Drive The 16 LedS * All The 16 Inputs Of The Driver Are Terminated At Banana Termination For Easy Wiring Of Any Experimental Setup. Input Switches : * 16 Spdt Switches As Logical Inputs Are Provided. * 16 LedS Provided To Display The Status Of The Switches. One End Of Each Spdt Switch Is Terminated At A Banana Termination For Easy Wiring. , Ic Tester It Is The Latest Microcontroller Based Universal Ic Tester. It Functionally Tests A Wide Variety Of Analog/Linear Ics Including Adc,Dac,Dpm Ics, Op Amps, Transistor Arrays, Waveform Generators And Digital Ics Including Microprocessors, Microcontrollers, Eproms, Rams, Peripheral Devices Apart From 74 Series Of Ttl Ics And 40/45 Series Of Cmos Ics
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
16.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
17.
Power #11267487 Technical Bid
Tender for Rate Contract For Procurement Of Material In Respect Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized , Procurement Of Material In Respect Of Std Ganderbal For The Year 2025-26 Or Till Next Stage Contract Is Finalized , 11 Kv Horn Gap Fuse Set 3 Phase 200A , 11Kv Link Rods For 11Kv Link Set 22 Feet Long With Insulating Bottom Grip Bamboo/Carbon Fibre , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 11 Kv Isolator, Double Break,3-Pole, 600Amp, Horizontal Mounting Type, With Earth Switch Complete Including Clamps And Fittings , 11 Kv 3-Core Current Transformer 800-400/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 750-375/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 600-300/5-5 A, ( Metering, Protection, Differential Core) , 11 Kv 2-Core Current Transformer 600-300/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 400-200/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 100-50/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 50-25/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 20-10/5-5 A, ( Metering, Protection) , 11 Kv Potential Transformer 110V, Accuracy Class 0.5 , Tension Fittings For 0.1 Acsr Conductor 70Kn , Tension Fittings For 0.15 Acsr Conductor 70 Kn , Tension Fittings For 0.2 Acsr Conductor 120 Kn , 185 Sqmm, 3Core , 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 3 Core ,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core, 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 240 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 120 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 120 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 11 Kv 630 Mm² Single Core Xlpe Cable Armoured, Frls (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , Tripping And Closing Coils Must Have Burden Between 250 To 350 Watts At 30V Dc With Housing , Tripping Coil Of 11Kv Alind Make Vcb , Tripping Coil Of 11 Kv Er/Vijai Make Vcb , Tripping Coil Of 11Kv Electric Field Make Vcb , Tripping Coil Of 11Kv Abb Make Vcb , Tripping Coil Of 11Kv Crompton Make Vcb , Tripping Coil Of 11Kv Stelmac Make Vcb , Tripping Coil Of 11Kv Sudhir/Schneider Make Vcb , Tripping Coil Of 11Kv Pascal Make Vcb , Closing Coil Of 11Kv Alind Make Vcb , Closing Coil Of 11 Kv Er/Vijai Make Vcb , Closing Coil Of 11Kv Electric Field Make Vcb , Closing Coil Of 11Kv Abb Make Vcb , Closing Coil Of 11Kv Crompton Make Vcb , Closing Coil Of 11Kv Stelmac Make Vcb , Closing Coil Of 11Kv Sudhir/Schneider Make Vcb , Closing Coil Of 11Kv Pascal Make Vcb , 33 Kv Link Set Heavy Duty- Post Type, 800A Complete , 33Kv Link Rods Fibre/Bamboo Oil Impregnated With Insulated Bottom Grip 30 Feet Long , 33Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm. , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type A , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type B For 0.2 Acsr Conductor , 30 Kv Lightening Arrestor Set, 10 Ka, Station Class, Zno, Polymer Gap Less (Set Consists Of 03 No.) With All Accessories Required For Installation. , 33 Kv Isolator Without Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Isolator With Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Current Transformer (33 Kv, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. Per Φ) 3-Core, 0.5 5P10, Ps-Class 3 Core- With All Accessories Required For Installation , 400-200/5-5 A (Metering, Protection And Differential Core ) , 250-125/5-5 A (Metering, Protection And Differential Core ) , 33 Kv Voltage Transformer (33 Kv/110 V, 1Φ, Multi-Core, Outdoor), (1No. Per Φ) With All Accessories Required For Installation , Tripping Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb) , Closing Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb, Stelmac Etc ) , 33 Kv Polymer Post Insulator 36Kv,170Kv Impulse, Creepage Distance 1224M , Earthing Complete (Spike Earthing Rod 20Mm,2.5 Mtr Long) , Galvanised Earthing Strips 50X6 Mm/ 25X3mm , Galvanised Nuts & Bolts Of Different Sizes And Sorts , Pg Clamps For 0.1 Acsr Conductor 400A Pressure Di-Cast , Pg Clamps For 0.15 Acsr Conductor 500A Pressure Di-Cast , Pg Clamps For 0.2 Acsr Conductor 630A Pressure Di-Cast , Prefabricated Galvanised Channel Iron/ Angle Iron Of Different Sorts As Required , Prefabricated Galvanised Flat Iron Of Sorts 50/25 8/6Mm Thick , Instrument, Tools And Other Equipments , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick With Sliding Mechanism , Bamboo Ladder 25 Long , 12V/7Ah Led Handheld Searchlight (Andslite/Philipls/Microtech,Fos) , Tool Kit Of Suitable Size With Tools ( Stanley / Taparia/Jon/Jk/ Make) Comprising Of :- Double End Spanners With Increases Or Decreased Sized Ends And D/Ring Type Following Sizes And Numbers Spanners 6-0, 7-8, 9-9-10, 10-11, 11-12, 12-13, 14-15, 16-17, 18-19, 20-21, 20-22, 24-27, 25-28, 30-32, Complete Set Cushion Grip, Pipe Wrench 12 Inch 1 No. 24 Inch 1 No., 12 Adjustable Chrome Plated Wrench, 8 Combination Plier Line Man Plier, 8 Long Nose Plier Length Nose Plier, 9 Crimping Plier Set, 230Mm-, 7 Length Cutting Plier, Hex Key(Ln Key) Set 11Pc Metric (1.5, 2, 2.5, 3, 4, 5,5.5, 6, 8, 10Mm 12Mm), 27Pc-1/2 Sq. Dr 12Pt Socket Set ( Comprising Of ) 20 Pc :- 1/2 Drive 12 Point Sockets: 10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,30,32Mm 6 Pc :- 1/2 Drive Accessories : 2 Pc Extension Bar: 5 And 10(125 And 250Mm) Universal Joint, 1 Pc :- Spark Plug Socket 6 Point 13/16, 1 Pc Sliding T-Bar 10(254Mm); 1 Pc Flip-Drive Rachet., 1/4 Torque Rench, 914Mm , 36 Inch Bolt Cutter (Taparia Make, 12 Hacksaw Frame With 12 No. Spare Blades, Steel Body Retactable Utility Knife With 12 No. Spare Knives, 12H 340Gms Ball Pien Hammer Wooden Handle, 16 900Gms Ball Pien Hammer Wooden Handle, 5 Mtr Measuring Tape, Cold Chesel 7/8 (22Mm), Centre Punch 8Mm (15/16 )X 115Mm(4 1/2 ), Good Quality Multi Meter ( Fluke, Motwane, Meggar Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. 24 Magnetic Torpedo/ Beam Level (3Vails) 300Mm -1 No. & 600Mm -1No., Files Flat/Round Type 8-12 Inch Long, Srew Driver Set Comprising Of 12 No.S Long Shank Having Star/Flat Type Tips With Heavy Duty Tefon Grips , Hv Detectors For All Voltages. (With Fiber Rod Telescopic) , Pliers (Make-Taparia/Stanley) , 11 Kv Hand Gloves ( Make 3M/ Crystal) , Earth Resistivity Tester (0-1000 Ohms) (Make-Motwane/Megger/ Fluke/Markoni) With Auto-Manual Options , Digital Insulation Resistance Tester 5000V (Make-Sonel/Megger/ Fluke/Equivalent) , 10 Feet A Type Ladder , Portable Welding Set , Portable Blue Lamp(Gas) , Portable Blue Lamp (Kerosene) , Insulation Tester And Continuity Tester 2.5 Kv Withvarious Kits (Make- Fluke/ Megger/Equivalent) , Clamp Meter/ Multi Meter ( Fluke, Motwane, Meggar/Meeca Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. , Heavy Duty Pulling & Lifting Machine 5 Mt , Control Relays With 3Oc+1Ef 2 Element Based Digital Of Following Make. , Mit- 114/104 (Er) Make. , Lnt M314a , Schneider , Simens 7Sr , Crompton 14C , Crompton 14Cn , Ashida 131A , Ashida 141 A/B , Ashida Adr241a , Ashida Adr242b , Abb Ref 615 , High Speed Master Relay With 12-63Vdc, 12-220 Vac Coil And 4 No+4Nc Driver Contacts , Battery Bank 30 V,100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type,High Impact Polyprophelene Copolymer Container,Flame Retardant (Exide/Amaron/Shoto/Hbl Make) , Battery Bank 36 V, 150 Ah Ultra Low Maintenance Tubular Battery Bank Compromising Of 3 No. Batteries Each Of 12 Volt (Hbl/Exide/Amaron/Luminous) , Battery Charger 36V, 40/60A With Full Wave Power Diode/Scr Based Recetification And Ripple Filtration. Avr Based Semi Digital With Inbuilt Autotransformer/Variant And Auto Manual Mode Having Digtal Precision Type/ Measuring Instruments, Led Type Indication, Inbuilt Buzzer/ Hoter Alarm During Technical Snags. The Charger Operating Ranges Must Be From 110V To 260 Vac Input Without Attoring Dc Output Through Smps , 7.5 Kva Servo Stablizer Copper Wound With Input Voltage Range 90V To 260V , Distilled Water For Batteries , Power Diodes P-Type/ N-Type ( 40 To 100 A) With Heat Shink , Charger Coil 240/36V Ac , Avr Card Compatile With Existing Chargers , Dc Volt Meter ( 0-60V) , Dimmer/Variac 110V To 260Vac , Power Transformer Equipments , Winding Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes Lv (Make-(Emco/Yoca/Excel) , Oil Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes (Make-(Emco/Yoca/Excel) , Power Oil Conforming To Is:335 Standards , 33 Kv Bushing For 10 Mva Power Transformer , 33 Kv Bushing For 6.3 Mva Power Transformer , 33 Kv Bushing For 5/4/3.15 Mva Power Transformer , 33 Kv Bush Rods For 10 Mva Power Transformer , 33 Kv Bush Rods For 6.3 Mva Power Transformer , 33 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11 Kv Bushing For 10 Mva Power Transformer , 11 Kv Bushing For 6.3 Mva Power Transformer , 11 Kv Bushing For 5/4/3.15 Mva Power Transformer , 11 Kv Bush Rods For 10 Mva Power Transformer , 11 Kv Bush Rods For 6.3 Mva Power Transformer , 11 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11Kv Outdoor Breaker Bushing , Oil Sealing For 33/11Kv Bushing Suitable For 1.0/3.15/2.5/6.3/10Mva , Miscellanous Items , Aluminum Thimble 120 Sqmm 3Mm Thick , Aluminum Thimble 185 Sqmm 3Mm Thick , Aluminum Thimble 240 Sqmm 3Mm Thick , Aluminum Thimble 300 Sqmm 3Mm Thick , Aluminum Thimble 400 Sqmm 3Mm Thick , Aluminum Thimble 630 Sqmm 4Mm Thick , Flexible Insulated Copper Bus/ Braid , Copper Bus Bars 12 Mm Thick , Aluminum Bus Bars 12 Mm Thick , T-Clamps For 0.1 Acsr 400A Presure Di-Cast , T-Clamps For 0.15 Acsr 500A Presure Di-Cast , T-Clamps For 0.20 Acsr 630A Presure Di-Cast , Isolator Pad Clamps 630A Presure Di-Cast , Single Phase Water Pump Motor, Power: 1 Hp , Led Lamp 15 Watt, B-22 Type (Make-Syska/Havells/Wipro/Surya/Ce/Gm) , 50 Watt Led Street Light With Fitting Complete (Make-Syska/Havells/Wipro/Surya/Ce/Gm) Ip-67 , Automatic Voltage Stablizer 5 Kva Copper Wound , 1.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 2.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 4 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 16 annual periodical maintenance Top (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Switch (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Socket (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Combine (Socket/Switch) (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Extension Board With 5 Socket With Fuse And Switch (Make-Anchor/Havells/Crompton/Equivalent) , Pvc Flexible Pipe 1/2 Dia , Ppr Pipe 0.75 Dia , Ppr Pipe 0.5 Dia , Poly Propline Rope-20-30 Mm , Motorized Wood Cutter (58Cc 3.5Hpchain Saw With 22 Inch Cutter Bar Power Full Engine) , Pt Clamps , 33Kv La Clamps 6Mm Thick , Pad Clamps (Aluminuim /Bi Metalic 600A)Presure Di-Cost , Baby Insulators With Nuts & Bolts , 33Kv Ct Clamps ( Threaded And Band Type Cu Made) Tin Coated , Crimping Tool Xple Cable ( Hydraulic Type Upto 120 Sqmm To 630 Sqmm) , Korean Mink Blanket 220X240 Cm 4Kg Weight.Rate Be Quoted Per Kg , Pvc Insulated Copper Bus Bar (50 Mm X 12 Mm) Including Nuts And Bolts 1250A , 11 Kv Vacuum Interrupters (800A/600A) Suitable For Vijai, Er, S&S, Alind, Crompton, Electric Field, Abb, Stelmac, Pascal. Indoor/Outdoor Breakers. , 11 Kv Vacuum Interrupters (800A/600A) Suitable For L&T, Schneider, Sudhir Etc. , 11 Kv Vacuum Interrupters Housing Of Below Mentioned Make. , Vijai And Easun Reyrolle (Per Phase) , Alind (Assembly Upper Set/ Lower Set). , Abb/Electric Field/Crompton/S&S ( Per Phase) , Sudhir And Schneider (Per Phase) , Outdoor Type Pcvcb Upper And Lower Part(Per Phase) , 11 Kv Vcb Equipments Below (Make-Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Voltmeter 11Kv/110V , Ampere Meter , Selector Switch- 16 Amps Vss/Ass , Led Panel Indicators , Push Button With 2No+2Nc , Master Tripping Relay With 4No+4Nc , Hrc Fuse With Base -16 Amps , Connecting Ribs , Auxilary Switch With 8No+8Nc Complete With Bracket And Lever , Auxilary Switch With 12No+12Nc Complete With Bracket Lever , Auxilary Relay -30 A , Trip Circuit Supervision Relay , Bell/Buzzer , Arching Chamber , Tripping Mechanism , Re-Setting Links , Operating Shaft , Shower Contact , Isolating Sockets , Brass Chamber , Lifting Rods , Rollers , Closing Shaft , Contact Bar , Aluminum Chamber , Spring Tension Rod , Gear Assembly , Bmr Mechanism Complete , 33 Kv C&R Panel Equipments (Make Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Bucholz Relay , Winding Temperature Relay , Oil Temperature Relay , Tripping Relay , Alarm Relay , Master Tripping Relay With 4No+4Nc , Tnc Switch 25 Amp. , Energy Meter Of Secure Make With Latest Series Premier 500 Of 11Kv Level And 33Kv Level With 5A Secondary. 11Kv/110V-5A / 33Kv/110V-5A , Electronic Hooter , Ampere Meter With Selector Switch , Voltmeter With Selector Switch , Hrc Fuse With Base , Bell/Buzzer , 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls , 12 Core . , 8 Core , 6 Core , 4 Core , 2 Core , 33 Kv Vcb Equipments (Make : Electricfield/Crompton/Abb/Bhel/Sudhir/Pascal/Beeco Lawrie/Megawin) , 33 Kv Vacuum Interrupter 1250A , 33 Kv Porcelain Post Insulator (Msli 1200+) , Operating Rods , Tripping/Closing Coils , Motor Charging 240, 1Cb, 0.1 Kv , Gasket , Operating Shaft , Mechanism Housing , Gear Assembly , Vacuum/Gas Charging Valve , Input/Output Housing Terminal Pads Din Pail Mounted Type , Xlpe Lt Cable 3.5 Core, Armoured, Fire Resistant Of Sizes , 95 Sq.Mm , 120 Sq.Mm , 185 Sq.Mm , 240 Sq.Mm , 300 Sq.Mm , 400 Sq.Mm , 2Mva/1Mva/630Kva/400Kva/250Kva/100Kva ,33/0.433 Kv, 3-Phase Distribution Transformers Eqiments: , 1600 annual periodical maintenance 4P Acb Drawal Type , Breaking Capacity 50Ka With Enclosure , Mccb ‐ 630 Amps , 36 Ka, 4P With Box Ics=100% Icu At 415 (Ka Rms) , Mccb ‐ 400 Amps , 36 Ka, 4P With Box , Mccb ‐ 250 Amps , 36 Ka, 4P With Box , Mccb ‐ 160 Amps , 36 Ka, 4P With Box , Mccb ‐ 1200 Amps , 36 Ka, 4P With Box , 120 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 240 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 400 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 630 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 33/0.433 Kv Transformer Lv Bushing Suitable For 100Kva To 2 Mva: , 33/0.433 Kv Transformer Lv Bush Rods Suitable For 100Kva To 2 Mva: , Safety Equipments , Safety Helmets Make-3M/Akamgo/ Hilson) , 33Kv Hand Gloves (3M/Crystal/Honeywell/Meeco/Jyot) , Safety Shoes Valcanised Rubber Made (Make-Allen/ Hillson/ Gasoline/Liberty/Acme/Bata/Neosafe/Honetwell) , Safety Belts Shock Absorber Type (Make-3M/Neo) , Safety Glasses (Make-Stanley/ 3M / Allen) , Safety Jackets (Make-Allen/ Hillson/ Gasoline) , Rain Protective Suit Complete- Pant And Jacket Ip-67 Protected , Fire Extingiusher Co₂ Type Of 6.5 Kg Capacity For Control Room , Fire Extingiusher Abc/Dpc Type Of 9 Kg Capacity For Control Room , Refilling Of Empty/Expred Fireextinguishers , Rubber Mat 1Mx2m 19Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
21.
Civil Aviation #11245899 AOC
Bids Are invited for All inclusive Annual Comprehensive Maintenance Contract of Microprocessor based addressable Fire Alram and Deduction (FDA) System (Bosch Make) with all components as per detail given in specifications for the following FDA components / configurations:(i) Microprocessor based 02 loop intellegent addressable UL/EN listed Fire Alram Panel with LCD display - 01 No.(ii) Intelligent electronics UL/EN listed addressable heat detector (Fixed cum-rate of rise type) - 04 Nos.(iii) Intelligent analogue UL/EN listed addressable multi criteria (photo+heat) detector - 298 Nos.(iv) Intelligent UL listed addressable Beam detector - 03 Sets. , Supply and replacement of Panel Controller suitable for Fire Controle Panel: AVENAR panel 2000, FPE-2000-SPC, Make: Bosch including configuration, programming and software upgradation for normal working of the complete Fire Alram Detection System etc. complete as required. , Supply and replacement of LAN Bus Module suitable for Fire Controle Panel: AVENAR panel 2000, FPE-2000-SPC, Make: Bosch including configuration, programming and software upgradation for normal working of the complete Fire Alram Detection System etc. complete as required. , Supply and replacement of Touch Screen Panel suitable for Fire Controle Panel: AVENAR panel 2000, FPE-2000-SPC, Make: Bosch including testing, connection for normal working of the complete Fire Alram Detection System etc. complete as required. , Supply and replacement of Power Supply Module (UPS) suitable for Fire Controle Panel: AVENAR panel 2000, FPE-2000-SPC, Make: Bosch including testing, connection etc. for normal working of the complete Fire Alram Detection System etc. complete as required. , Supply and replacement of Battery Module suitable for Fire Controle Panel: AVENAR panel 2000, FPE-2000-SPC, Make: Bosch including testing, connection etc. for normal working of the complete Fire Alram Detection System etc. complete as required. , Supply and replacement of 02 Nos. Batteries of capacity 7 Ah, 12 V suitable for Fire Controle Panel: AVENAR panel 2000, FPE-2000-SPC, Make: Bosch including testing, connection etc. for normal working of the complete Fire Alram Detection System etc. complete as required.
Contract Date: Ref. Documents Contract Value : 10.56 Lakh
Boards / Undertakings / PSU No of Bidders 5
22.
Information and Broadcasting #11243113 AOC
Tender for Supply And Installation Of Fire Alarm System For Tm#5 At Tnpl Unit Ii , Supply Of Fire Alarm System , Addressable Fire Alarm Panel With 2 Loop Cards Suitable To Accommodate 250 Nos Of Devices Per Loop With Networking Card , Addressable Multi Sensor Smoke Detector With Base , Addressable Optical Smoke Detector With Base , Addressable Heat Detector With Base , Addressable Manual Pull Station / Break Galss Unit Of Aluminium Die-Cast Materials Enclosure , Addressable Control Module With Back Box And Cover Including Junciton Box As Required For Ahu Tripping , Sounder Cum Strobe -Inlcuding Junction Box As Required , Addressable Sounder Control Module With Back Box And Cover , Short Circuit Isolator Modules , Response Indicator With Back Box , 5A Rating 24V Dc Power Supply Unit For Sounder Cum Strobes With Inbuilt Battery Charger And Batteries For 60 Minutes Continuous Operation. , 2Cx1.5Sq.Mm Atc Conductor Twisted Pair Screened Shielded Armoured Cable For Addressable Loop Including Cable Termination, Diuble Compression Gland, Cable Lugs Etc. , 2Cx1.5Sq.Mm Copper Conductor Armoured Cable For 24V Dc Power Supply To Sounder Cum Strobes Including Cable Termination, Diuble Compression Gland, Cable Lugs Etc. , Installation Of Fire Alarm System , Addressable Fire Alarm Panel With 2 Loop Cards Suitable To Accommodate 250 Nos Of Devices Per Loop With Networking Card , Addressable Multi Sensor Smoke Detector With Base , Addressable Optical Smoke Detector With Base , Addressable Heat Detector With Base , Addressable Manual Pull Station / Break Galss Unit Of Aluminium Die-Cast Materials Enclosure , Addressable Control Module With Back Box And Cover Including Junciton Box As Required For Ahu Tripping , Sounder Cum Strobe -Inlcuding Junction Box As Required , Addressable Sounder Control Module With Back Box And Cover , Short Circuit Isolator Modules , Response Indicator With Back Box , 5A Rating 24V Dc Power Supply Unit For Sounder Cum Strobes With Inbuilt Battery Charger And Batteries For 60 Minutes Continuous Operation. , 2Cx1.5Sq.Mm Atc Conductor Twisted Pair Screened Shielded Armoured Cable For Addressable Loop Including Cable Termination, Diuble Compression Gland, Cable Lugs Etc. , 2Cx1.5Sq.Mm Copper Conductor Armoured Cable For 24V Dc Power Supply To Sounder Cum Strobes Including Cable Termination, Diuble Compression Gland, Cable Lugs Etc.
Contract Date: Jun 06, 2026 Contract Value : 12.85 Lakh
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : 13.89 Lakh
Boards / Undertakings / PSU No of Bidders 2
West Bengal View Result →
24.
Banking and Finance #11236945 AOC
Bids Are invited for Loss Prevention Active And Passive Fire Protection Systems Fire Door - Providing, Fixing, Testing And Commissioning Of Two Hour Fire-Rated Single/Double Panel Door & Door Frame According To Approved Design & Shop Drawing Door Frame Made Using 1.2 Mm Thick Galvanized Steel Sheet Conforming Is 277 For Formed To Single Rebate Profile Of Size 100Mmx50mm & With Maximum Bending Radius Of 1.4 Mm. Door Frame With Mitred Joints To Have 40Mm Width All Around The Lobby Side. Frame To Be Provided With Back Plate Bracket For Installation Using Anchors. The Frame To Be Fixed Using 8Mm Expansion Anchors (Hilti/Equivalent) As Per Approved Design. Rate To Also Include Providing, Erecting & Fixing Single/Double Leaf Minimum 44Mm Thick Metal Finish Door Shutter Constructed From 0.8Mm Thick Galvanized Steel (Gpsp) Sheet Conforming Is 277, Fully Flush, Double Skin Door Shell With Lock Seam Joints And Stile Edges, Internal Reinforcements Provided At Top, Bottom & Stile Edges For Fire Rating. The Internal Construction Of The Door Should Be A Resin-Bonded Specially Designed Honeycomb Structure With Reinforcements At Top, Bottom & Stile Surrounds. Doors Shall Be Factory Prepped For Receiving Specified Hardware. Vision Panel, Where Specified, Shall Be 6Mm Thick Clear 2 Hour Fire Rated Glass. The Door Assembly Shall Be Fire Rated For 120 Minutes , A - Double Door , B - Single Door , Fire Rated Paint - Fire Rated Paints For All Partition Wall Are Specialized Intumescent Coating That Swell When Exposed To High Heat, Forming A Thick, Char-Like Barrier For 30 To Over 120 Minutes. Ensure The Paint Complies With Local Fire Safety Codes, Such As Bs 476, Din En 13501,Or Astm. Varies By Product With Some Providing 10-12 Sq.M/Ltr. , Fire Suppression System - Supplying, Installation, Testing And Commissioning Of 58.5Kg Cylinder/Valve Assembly. , B - Supplying, Installation, Testing And Commissioning Of Novec 1230 - Agent Filled In The Above Cylinder. , C - Supplying, Installation, Testing And Commissioning Of Master Valve With Automatic Cum Manual Actuator, Including Trim Complete With All Accessories. , D - Supplying, Installation, Testing And Commissioning Of Slave Valve With Actuator, Including Trim Complete With All Accessories. , E - Supplying, Installation, Testing And Commissioning Of Actuation Hose , F - Supplying, Installation, Testing And Commissioning Of Discharge Hose , G - Supplying, Installation, Testing And Commissioning Of Nrv , H - Supplying, Installation, Testing And Commissioning Of 58.5 Kg Cylinder Strap. , I - Supplying, Installation, Testing And Commissioning Of Nozzles , J - Supplying, Installation, Testing And Commissioning Of Warning Sign Stickers. , K - Supplying, Installation, Testing And Commissioning Of Astm Schedule 40(Seamless Pipe) (A106 Grade B) , K I - I) 25Mm (6.2 Mm) , K Ii - Ii) 32Mm (Header) (8 Mm Minimum) , Fire Alarm And Detectors - Supply, Installation, Testing & Commissioning Of 1 Zone Gas Release Panel (Control Panel) , B - Supply, Installation, Testing & Commissioning Of Smoke Detector , C - Supply, Installation, Testing & Commissioning Of Abort Switch. , D - Supply, Installation, Testing & Commissioning Of Manula Call Points. , E - Supply, Installation, Testing & Commissioning Of Electronic Strobe With Hooter. , F - Supply And Laying Of Frls Armoured Cable 2Cx1.5 Sqmm , Portable Fire Extinguishers - Supply And Installing Isi Marked As Per 15683 Fire Extinguisher, Carbon-Di-Oxide Type Capacity 4.5 Kgs Complete In All Respect. , B - Supply And Installing Abc (Powder Type) Fire Extinguisher Mild Steel Cylinders Isi Complete Confirming To Is 15683. , C - 6 Kgs. , D - 2 Kgs. , E - Supply, Installation, Testing And Commissioning Of Exit Sinage Of Photo Luminescent On Aluminium Sheet Of 1.0 Mm Containing Lumigen-Iii As Base Chemical, Covered With Uv Stabilized Coating Size 450 X 200. Total Quantity : 1003
Contract Date: Ref. Documents Contract Value : 8.71 Lakh
Government Departments No of Bidders 3
25.
Power #11228270 Technical Bid
Tender for Rate Contract For Line Material Ed-I Parade Jpdcl For The Financial Year 2026-27. , Al Thimbles , Aluminium Thimble 120Mm2 , Aluminium Thimble 185 Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Paints(Asian, Nerolac Or Its Equivalent) , Yellow Paint , Red Oxide Paint , Heat Shrinkable Kit (Outdoor Type)11Kv Straight Through Type , Heat Shrinkable Kit (Outdoor Type)11Kv Straight Throgh Type 185 Mm2 , Ab Cable Kit 185 Mm2 O/D Type , Pin Insulators , 11 Kv Pin Insulators Polymer Type , Lt Shackle Insulator , Guy Insulators Lt , 11 Kv D.O Set (Heavy Duty) , 11 Kv Link Set (Heavy Duty) Copper Strip Of 50X6mm , 11 Kv Horn Gap Set (Heavy Duty) , 11 Kv 3 Limbs With Pipe 20 Feet With All Accessories G.O Set (Heavy Duty) Complete , G.I. Wire 8 Swg , Iron Clad Switches3 Phase , 63 annual periodical maintenance , 100 annual periodical maintenance , 200 annual periodical maintenance , 300 annual periodical maintenance , 400 annual periodical maintenance , 630 annual periodical maintenance , Pvc Tape , Manilla Rope Of Different Sizes And P-P Rope Of Different Sizes , Lifting Pulley Machine Isi Make 5-8 Ton , Gi Earthing Plate2x2x6mm , Gi Pipe 1.5 Inch Dia 20 Long , 11 Kv Rubber Hand Gloves Isi Make(Duck Back)/ (Rychem Class 2) , Galvanised Nuts & Bolts Of Sorts , Xlpecable 3.5 Core Un Armoured Lt (Of Reputed Make Like Havells Polycab,Or Its Equilavent) As Per Is Standard Amended Upto Date As Mentioned In Sbd , 300 Mm2 , 400 Mm2 , Xlpe Cable Single Core Un Armoured Lt (Of Reputed Make Like Havells Polycab Or Its Equilavent ) As Per Is Standard Amended Upto Date As Mentioned In Sbd , 25 Mm2 , 11 Kv Cable 3 Core Xlpe Of Reputed Make Like Havells, Polycab Etc Or Its Equilvalent Make As Per Is Standard Amended Upto Date As Mentioned In Sbd , 25 Mm2 , 35 Mm2 , 50 Mm2 , 70 Mm2 , 95 Mm2 , 120 Mm2 , 185 Mm2 , 240 Mm2 , 300 Mm2 , 400Mm2 , 11Kv Xlpe Areal Bunched Cable Of Reputed Make Like Havells, Polycab Etc Or Its Equilvalent Make As Per Is Amended Upto Date As Mentioned In Sbd , 50 Mm2 , 70 Mm2 , 95 Mm2 , 120 Mm2 , 185 Mm2 , 300 Mm2 , 400Mm2 , 3.5 Core Lt Xlpe Areal Bunched Cable Of Reputed Make Like Havells, Polycab Etc Or Its Equilvalent Make As Per Is Standard Amended Upto Date As Mentioned In Sbd , 25 Mm2 , 35 Mm2 , 50 Mm2 , 70 Mm2 , 95 Mm2 , 120 Mm2 , 185 Mm2 , 300 Mm2 , 400Mm2 , Pvc Spacers , Pvc Spacers 4 Wire , Bamboo Ladders , Bus Bar Insulators , Voltage Detector (Honeywell) , Torch (Havells/ Eveready) , Earthing Rod/ Earthing Spikes , Gi Strips , Lt Pole Distribution Box 1 Phase With Provision Of 10-12 Connections Raychem Make As Per Relevant Is. , Lt Pole Distribution Box 3 Phase With Provision Of 4 Connections Raychem Make As Per Relevant Is. , Bimetallic Clamp M-20 , Bimetallic Clamp M-30 , Stringing Clamp , Prodigy Meter , Ct/Pt Unit Of All Ratios (Dry Type) With Trivector Meter , T-Clamp 400 annual periodical maintenance , T-Clamp 630 annual periodical maintenance , Pg Clamp , Lt Ab Suspension Clamp , Hook On Meter(Htc) , 3 Phase Energy Meter (Secure Download Type) , Single Phase Energy Meter (Hpl Download Type) , Led Sreet Light (Crompton/Orient/ Greatwhite) , 100 Watts , 120 Watts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
26.
Power #11223257 Technical Bid
Tender for Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2026-27 , Supply Of : , 11 Kv Link Set (Station Type) Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Link Set (Line Type) Heavy Duty. Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Air Break Switch With Pipe & Handle Complete (3 Phase, 600 Amp) (Is: 9920 (Part-I To Iv)) , 11 Kv Drop Out Fuse Set 3 Phase 400A (Is:9385 (Part-I To Iii) As Amended Upto Date) , Gapless Surge Arrestor, 9 Kv, 10 Kv, La With (Polymer/Porcelain) Housing, Stn. Type (Is: 3070 Part-3) , 11 Kv Pin Insulator With Pins 12 Kn. (Is:731 And Is:3188) , Lt Shackle Insulators With Mukki Clamps (16 Kn) Of Standard Make With Nuts And Bolts , Galvanised Nuts And Bolts Of Sizes. 6,7,8,9,11,12X1/2 Dia Half Thread. , G.I Wire 8 Swg. , Guy Wire 7/14 Swg. , Guy Rods With Turn Buckle 5 Long Complete , 11 Kv Tension Disc/Suspension Disc (Is:731 And Is:3188) , Fabricated Gi Channel, X-Arms Of Sizes (75X40x6) Mm (50X50x6)Mm And (100X50x6) Mm. , Fabricated Gi Angle, (50X50x6mm) , Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is , Aluminium Thimbles 1 Mva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 70 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 95 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 120 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , Galvanized Earthing Strips 50Mm X3mm. , Bobin Insulators Clamps/Cliffs. , Back Clamp Collars/Pole Collars G.I. , Galvanized Abc Cable Hooks/I Hooks , Aluminum Paint (Asian/Nerolac/Berger) Make. , Red Oxide Paint (Asian/Nerolac/Berger) Make. , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Of Sizes , 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit Of Sizes , 300 Mm Sq 11 Kv Heat Shrinkable Cable Jointing Kit , 11 Mtr. (Is 2713 540 Sp 56)Steel Tubular Poles , 9 Mtr. (Is 2713 540 Sp 33)Steel Tubular Poles , 8 Mtr. (Is 2713 540 Sp 15)Steel Tubular Poles , 30Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 50Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 100Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 630 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 400 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 200 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 160 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 100 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 63 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv , 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter (With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter 25 Mm And Bottom Section Diameter 45 Mm) With Earthing Spike Of Standard Make , Battery Operated 11-33 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Natural Latex 11Kv Rubber Gloves (Type-2 Is 4770; Isi Mark) With Test Voltage =17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma (Rms) [ Isi Mark And Is Conformation On Each Glove] , White Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Yellow Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt] , Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 To 36)-1 Set, Wrench 12-1 No, Measuring Tape 25 Mtr-1 No, Hexa Frame With Blade-1 No, Tester-1 No, L Key -1 Set And Combination Spanner (6 To 36)-1 Set Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Manually Operated Megger (500/1000 Mega Oms) , Lt Fuse Set (630 Amp) 11 Kv Polymer Type , Gi Chemical Earthing 2 Mtr With Chemical Bag , Search Light (Led) 1 Km Range , Bamboo Ladder 18 Long , Aluminium Folding Ladder 20 Ft Long , Wooden Ladder A Class Budloo [Finished Length Of 17 (3 By 1.5) ; Finished Step (2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13] Alongwith Ms Straps On Both Side Of Each Step , 16 Mm² Cable (2C) From Lt Line To Meter ,1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type (Is 1554 Part 1 Ammended Upto Date) Polycab/Havells/Paramount/Or Equivalent , Single Phase Smd Box With Bus Bar (8 Way) , Three Phase Smd Box With Bus Bar (12 Way) , Anti Climbing Devices With Clamps , Sl Clamp , Lt Shackles With D Clamp , Suspension/ Tension Clamps With Eye Hook , Danger Plate , Pole Butt , Eye Bolt , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Insulated)Mm² Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 25 + 1 X 95 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , Smdbs Single Phase , Smdbs Three Phase , Hoose Pipe 1.5 , 300 Mm Sq Ab Ht Cable Single Core , 45 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 70 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 3/4 Pvc Pipe For Service Line Fixing On Pole With Ties Belt , 200 Watt Led Flood Light/Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 150 Wattled Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 110 Watt Led Light Ip 66 Cerified With Bis, Roh Ce & Company Scaner Bar-Code , 130 Watt Led Light /Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 90 Watt Led Lights / Luminaries Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , Led Drivers For 200 Watt Led Lights , Led Driver 130 Watt Led Light Of Standar Make Pasted With Company Scaner Code , Led Driver For 120 Watt Led Lights Pasted With Company Scaner Code , Led Driver 110 Watt Led Light Pasted With Company Scaner Code , Led Driver For 80 Watt Led Light Pasted With Company Scaner Code , 19 Mm Dia Pvc /Hdpe Conduit , 25 Mm Dia Triple Lyer Hdpe Conduit , 50 Mm Dia Triple Lyer Hdpe Conduit , 70 Mm Sq Tripl Layer Hdpe Conduit , 1.5 Mm Sq Copper Wire , 2.5 Mm Sq Copper Wire , 4 Mm Sq Copper Wire , 6 Mm Sq Copper Wire , 2 Amper Single Pole Mcb , 6-10 Ampere Single Pole Mcb With Box , 16 Ampere Double Pole Mcb , 25 Ampere Mcb 04 Pole , 32 Ampere Single Pole , 32 Amper Double , 32 Ampere Tpn 04 Pole Mcb , 40 Ampere Tpn 04 Pole Mcb , 63 Amper 4 Pole Mcb , 100 Ampere Mccb Of Standar Make , Led Bulb 09/11Watt Of Standard Make Certified Isi Make , Led Bulb 50/45 Watt Of Standard Isi Certified Make , Time Delay Relay For Servo Stabilizer , Astrnomical Timer Of Standard Make , 50 Hz Contractor Of Standard Make , Distilled Water , Ms Nuts, Bolts , Washers Of Sizes , 11 Kva Cable Joint Kit , 11 Kva Cable Termination Kit , 10-95 Sq Mm Al, Thimbles , Cable Jointing Thimble 10-95 Sq Mm , 6 Sq Mm 02 Coreal, Cable Standard Make , 10 Sq Mm 02 Core Al Cable , 16 Sq Mm 02 Core Cable , 25 Sq 02 Core Al Cable , 6 Sq Mm 04 Core Al Xlpe Cable Of Standar Make , 10 Sq Mm 04 Core Al Xlpe Cable , 16 Sq M 3.5 Core Xlpe Cable , 25 Sq 3.5 Core Xlpe Cable , 35 Sq Mm 3.5 Core Cable , Pvc Tape Roll , 8 Inche Taparia Plair , Star Type Screw Driver Big Size , Star Type Screw Driver Medium Size , High Beam Torch Light , Tool Box , 100 Amper Bus-Bar 1 18 To 24 Copper , 100 Amper Bus-Bar 1 18 To 24 Aluminum , 08 Way Termination Blocks / Connector , 150 Watt Led Driver 700 Amper Constant Current Philpps, Havells, Fulham Certified With Bis, Roh , Ce With Company Bar-Code Scanner , 130Watt Led Ornamental Hanging Type Luminary Housing (Dgl-103-M) D Fitted With 130 Watt Led Panel For 9Mtr Longt Iron/Ms Composite Pole. , Batton Type Brass Holder , Pendent Holder , Ms Junction Box Complete With Fixed Clamps Nuts And Bolts , Abs Transpernt Junction Boxs , Time-Delay Rellay , Repairs Of 10Kva To 25 Kva Avr , Transformer Oil , M.S Boss Fitted For 100 Ampere Mccb Complete , Earthing Spike- Rod 2 Mtr Long , 08 No.G.I Wire , 80 To 120 Sq Mm Al, Thimble , 11 Kv Link-Set , 11 Kv Drop-Out Set , 11 Kv Surge Lighting Arrestor , Extension Cords Heavy Duty , 250X500 Mm Pcd G.I Door Plate For 9/7 Mtr Long Octogonal Pole , Piercing Connectors Of Sizes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
27.
Housing Urban and Rular Development #11223252 Technical Bid
Tender for Supply Of 1 Loop Analogue Addressable Fire Alarm Control Panel Expandable Up To 4 Loop, Loop Current 500Ma Maximum Per Loop, Dual Flash Based Microprocessor, Supports To Connect 240 Addressable Devices One Each Loop Via Fully Digital Communication Protocol, Equipped With A White Backlit Display (240X64 Pixel Resolution) Graphical Lcd Display With At Least 6 Lines Of Information, 200 Fire Zones (Soft Zones), Fully Programmable Via Alphanumeric Keypad Or Configuration Software, Dedicated Usb And Rs-232 Serial Port For Direct Or Pc Connection. 5500 Events Storage, Loop Current 500 Ma, Panel Shall Be Equipped With In-Built Millimeter For Live Monitoring Of Loop Current, Earth Voltage, Loop Voltage Etc., Installers Logo Application, Can Be Networked To Compatible Addressable Panels And Repeater Panels By Adding A Network Card, Features Battery Charger Status And Temperature, Supports Programmable Cause / Effect On Outputs, Panel Housing Meets Ip30 Ingress Protection Classification. , Supply Of Intelligent Analogue Optical Smoke Detector With Advanced Optical Chamber And Smoke Inlet Design To Provide Resistance To Entry Of Dust To Provide Immunity To False Alarms, Programmable Multiple Smoke Sensitivity Level Setting, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bi-Color Leds With 360O View Of Status, Auto-Addressable/Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-7 & En 54-17 Standard. , Supply Of Intelligent Analogue Class-P Heat Detector With Two Thermal Sensitivity Level, The Two Level Corresponds To Rate-Of-Rise (Ror) A1r Class (Most Sensitive) And Class Bs (Least Sensitive), Thermal Alarm Threshold For Ror A1r Class 58Oc And Bs Class 78Oc, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bicolor Leds With 360O View Of Status, Auto Addressable/ Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-5 & En 54-17 Standard. , Supply Of Standard Detector Base For Mounting The Compatible Addressable Detectors. , Supply Of Intelligent Sounder Interface Module Allows Connecting Conventional Sounder Or Sounder Beacon To Addressable Loop, With In-Built Short Circuit Isolator, Allows For Two Stage Alarm Capability, Addressed Through Auto And Manual Options. Approved By Lpcb For En 54-17 & En 54-18 Standard. , Supply Of Conventional Wall Sounder With Beacon For Providing Audible And Visual Alarms In Response To The Output Signal From The Control Panel, 32 Selectable Tone And Adjustable Sound Level, Maximum Output Volume @ 1M Distance 100 Db(A), Output Tone Frequency Range 440 Hz To 2900 Hz, Visual Alarm Device Output Frequency 0.5 Hz, Approved By Lpcb For En 54-3 Standard. , Supply Of Intelligent Analogue Multi-Criteria (Combination Of Smoke And Heat) Detector With Special Algorithms To Utilize Information From Both Smoke And Heat Sensing Elements To Ensure High Level Of Immunity To False Alarms Without Compromising Genuine Alarm Sensing Performance, Programmable Multiple Smoke Sensitivity Level And 9 Modes Of Operation, Bi-Directional In-Built Short Circuit Isolator To Protect Against Cable Faults, Dual Bicolor Leds With 360O View Of Status, Auto Addressable/ Electronically Addressed, Utilizes Fully Digital Communication Addressable Protocol With High Noise Rejection. Approved By Lpcb For En 54-5, En 54-7, & En 54-17 Standard. , Supply Of Single Loop Driver Card Designed For Use With Compatible Analogue Addressable Panels, Provides Control And Connection/Communication To Maximum 240 Addressable Device Per Loop. , Supply Of Intelligent Analogue Manual Call Point With Resettable Operating Element, With In-Built Bidirectional Short Circuit Isolator. Bi-Color Led For Local Indication Of Device Status, Single Action Operation, Reset To Normal Condition Using Special Reset Key, Clearly Visible Alarm Flag In The Activated State. Approved By Lcpb For En 54-11 Standard. , Supply Of Mounting Accessories Like Back Box For Detectors, Devices & Cable Glands, Etc. , Supplying And Laying Of 2C X 1.5 Sq.Mm Pvc Insulated Copper Conductor Armoured Cable Encased Inside (By Providing And Laying) 1.5 Dia Pvc Insulated Conduit/Pipe Along With Fittings And Fixtures. Complete Job Includes Cost Of Material (Pvc Conduit, Cu Cable). Labour And Transportation. , providing and Fixing Of Wall Mounted Automatic Fire Extinguishers Abc Type Of Capacity 6 Kg Using Two Heat Sensing Quartzoid Bulb With Valves For Detection & Extinguishing Of Fires, Wall Mounted Automatic Fire Extinguisher Powder Based (As Per Is 4308) Automatic, Mild Steel, Hose Length 500 Millimeter, Quartzoid Bulbs Temperature Rating 68 Degree Celsius, Pressure Testing-Ped Certificate/ Ce Marking To Ped 2014/68/Eu, Annexure 3 (Module H) From Eu Notified Body. , providing and Fixing Of Stored Pressure Water Mist Based Fire Extinguishers 6 Liter Capacity. Bs En Standard Based Portable Fire Extinguishers, Conformity To Standard En 3-7 + A1: 2007 & En 3-8;2006 With Latest Amendment, Weight Of Filled Portable Fire Extinguisher (Kg) 10.438, Suitable For Class -A Fire Ratings As Per En 3-7 13A, Fire Rating For Class -F 75F,Operating Temperature (-30° C≤ N =60° C ), Warranty For The Complete Product 5 Year, Operating Temperature (+5° C To + 60° C), Service Pressure 15 Bar, Burst Pressure 112 Bar, Minimum Discharge Time (Seconds) Required As Per En Standard 12 Second, Shelf Life (Life Cycle) Of The Fire Extinguisher 10 Years, Marine Equipment Directive (Med) Approved Ce Certification From Eu Notified Body, Ce Identification Number Of The Notified Body (Must Declare),Ce 1128, Availability Of Test Report From Central Govt./Nabl/Ilac Accredited Lab To Prove Conformity To Specification Test Report No 1329B, Issue: 04, Test Report Date 20.07.2018 Name Of The Lab Bre Global Ltd. , providing and Fixing Water Mist & Caf High Pressure 50 Ltrs. Trolley (As Per En 1866-1:2007-08), Working Pressure 31 Bar, Air Bottle Capacity 6 Litre 300 Bar Pressure, Approved By Peso (Petroleum And Explosive Safety Organization),Fire Extinction - Suitability With Standard Afff 6% Confirming To Is 4989 Or Ul 162 Standards Class - A Fires, Class - B Fires, Class - B Polar Solvent Fires, Live Electrical Fires - 1000 V As Per En 3-7:2004+A1:2007 Tested For 35 Kv, Certification From Nabl Accredited Lab And Any Central Govt. Lab. (Tested In Indian Condition) As Per En 1866-1:2007-08. Test Report Shall Be Enclosed Along With The Offer, The Product Should Be Ped Certified To Ped 2014/68/Eu, Annexiii (Module H), The Supplier Should Have A License From Peso For Refilling & Storage Of High Pressure Gas Cylinders.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
28.
Defence #11213485 AOC
Tender For Additional / Alternator To P-266 Of 5 Afdc And Provision Of Misc E/M And B/R Services In Various Buildings And Certain Minor Works At Afs Pune Under Ge Af Lohegaon.; 1 Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering all as specified and directed. 2 Dismantling timber in fillets rails, posts, rafters, purlins etc over 40 Sqcm in section in unframed work 3 S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 4 S&F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Eaves boards, fixed with self tapping screws as specified 5 S & F Rolled Mild Steelroof trusses(framed),trussed ,purlins ,rails and fastenings etc.,confirming to Fe 410 - S including distance pieces, cleats, etc., complete. 6 S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering.doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening andfixing complete (Eaves board fixing ) 7 S & F 6mm thick asbestos cement plain building boards fixed to steel frameowrk with screws all as specified and directed ( For Eaves Board). 8 S &F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-w (Gde E-250 quality A) all as specified and directed. 9 M & L for Preparation of newsteel/iron surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paintover red oxide primer for material and labour complete all as specified. 10 M & LPCC B1 1:2:4 (12.5mm graded aggregate) for in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. (Note :- Bed boxes and Coping on wall to fill up the gap) 11 Demolition of Brickwork or stone/boulder masonry/PCC bloack masanory,built in cement motar all as specified and directed. 12 S & F brick work with fly ash bricks,straight or cuved on plan exc 6m mean radius built in CM 1:4all as specified and directed. (Note : 1. For filling the Gap between sheet and wall 2. Clsoing of ventilaots ) 13 Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge 14 Material and labour for suspended false ceiling usinganodized aluminum snap grid frame work.Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete. Perforated particle board/tiles for insulation and acoustic purposes, 60 x 60 cm size, fixed on snap grid 12mm thick confirming to IS 2095, 2995 Part I fixed with 25mm dry wall screws @ 230 mm C/C with screw driver to match surface attachment. Finally board have to be joined and finished to have a flush look using jointing compound/tape as per manufacturer instruction. With Designing as per direction in two steps complete all as specified and directed by Engineer in Charge. 15 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:4and is to be finished even and smooth with out using extra cement complete all asspecified directed 16 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 17 M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than than 50gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint or required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.9 litre/10 sqm over new surfaces/old surfaces of wall all as specified and directed. 18 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out hard dense soil 19 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting poin 20 Hard coare of broken stone aggregate, of gauge n.exc 60 mm 21 M&L for cement concrete Type D -2 1:4:8 (40 mm graded agg) in foundation fillig/path and mass concrete 22 Formwork to sides of flat concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter 23 M&L Forming Contraction (Dummy) joints 30 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade A in plinth protection 24 Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) 25 S &F 605 x 605 mm Anodised aluminium snap grid frame work for false ceiling all as specified 26 Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified 27 Dismantling boarding, any description, fixed in any position with nail 28 Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete 29 M&L rendering 15mm thick on surface of concrete surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 30 Demolition of stone / block masonry built in CM 1:4 31 M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) and set in CM (1:6). 32 Preparing new wall surface, providing and applyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of oil emulsion 33 Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners withholdfasts and brackets, complete 34 S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 35 S&F Sheet glass 5.5 mm thick ordinary quality and glazing fixedin aluminium doors squareexc 0.5 sq. m in each pane 36 S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers 37 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, 38 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats 39 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) 40 M & L for 100mm thick PCC type B-2 (1:2:4) using 40mm graded aggbnas in flooring finshed even and smooth w/o using extra cement. 41 M & L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded agg finished even and smooth w/o using extr cement. 42 M & L for nonskid coloured ceramic tiles 7 to 8 mm thick (square/ rectamgular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors (Superior/ Premium quality), set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15mm thick screed bed in CM (1:6) complete all specified and directed. 43 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer in Charge. 44 M & L fire resistant paint on steel surface over a coat of primer complete alll as specified (Note: The primer is of same material of 1:1 dilution application) 45 S & F of mineral fibre reinforced false ceiling tiles (all height)of size 595X595 mm of approved texture, design and pattern. The tiles should have humidity risistance RH of 99%, Light resistance greater than 85% , thermal conductivity K=0.052-0.057 W/mK, Fire performnce As per (BS476 Pt-6&7) in true horizontallevel suspended on interlocking T-grid of hot dipped all around ganvanisedIron Section of 0.33mm thick (galvanised @ 120GSM)bcomprising of main T runner of 15 X32 mm of length 3000mm, cross T of size 15X32 mm of length 600mm to form grid module of size 600X600 mm suspended from ceiling using galvanised Mild steel item ( galvanised @ 80GSM) 50mm long 8mm outer dia M-6 Dash Fastner, 6mm diameter fully threaded hanger rod upto 1000mm length and L-shped level adjuster of size 85X25X2mm, spaced at 1200 mm center to center along main T, the system should rest on perpfery walls/ partition with the help of GI perimeter wall angle of size 24X24X300mm made of 0.40mm thick sheet, to be fixed to the wall with the help of the plastic rawl plug at 450mm center to center & 40mm long drywall S.S screws. The exposed bottom portion of all y- Sectionused in false ceiling support system shall be prepainted with polyster baked paints, for sll heigth. the work shall be carried outas per specification drawing adn as per the direction of the Engr-in-charge with 16mm thick Bevelled traingular Mineral Fibre faalse ceiling (NRC 0.5 to 0.6)) 46 Taking down and of chowkats or frames exc 1.5 sqm n exc 4 sqm each 47 S & F Anodised aluminium frame powder coated to (minimun thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 48 S & F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,ruber neoprene packing, handk=les 2 Nos in each door, hinges, anodises aluminium snap beading screws etc. complete all as specified. 49 Cuting holes exc 150 sqcm but not exc 400 Sqcm into or through brick walls built in cement mortar of any description and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-I as required 50 m&L two coats or Oil Bound distemper on Cement concrete surface over a coat of primer as per the shed directed by the engineer-ncharge, complete all as specified. 51 M&L for treating small articles such as ends of posts, holdfasts etc with tar or coal tar black paint; area exc 0.1 Sqm but n exc 0.5 Sqm each 52 S&F sheet in repairs glass 4.8 mm thick exc 0.5 sqm area ordinary quality and glazing with oil putty/rubber gasket fittings all as specified and directed. 53 M & L in repairs for 12mm Prelaminated particle board, interior grade, prilaminated both side with decorative choice lamination fixed with screws to timber/Aluminium frame work complete all as specified and directed. 54 S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 1000 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I 55 S & F in repairs 20 mmBrass valves ,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed 56 S&Fbib tap cast copper alloy chromium plated butterfly handle screwed down screwed for iron pipe completed (15mm dia tap). 57 S&F GI tubingof 15 mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 58 S&F GI tubingof 20mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 59 S&F GI tubingof 25mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 60 S&F25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 61 S&F20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 62 Dismantling wrought iron or mild steel work of any description not otherwise provided for. 63 S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St 240 all as specified and directed.(Eaves Baords) 64 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 65 Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar including all quoins, arches , pillars etc all as specified and as directed 66 M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified 67 M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified 68 M&L for reinforced cement concrete M 20 using 20mm crushed stone aggregate as in roof slabs supported on walls surfaces of concrete flat all as specified. 69 M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement. 70 M&L for preperation of new concrete /plastered surface of any description, two coat of plastic emulsion paint over a coat of primer complete all as specified and as directed complete all as specified and as directed. 71 M&L for Powder Coated (Minimum thickness of powdercoating 50 micron)Anodised aluminium frame of standerd section for doors, windows, ventilators and partitions withdoublerebates including joining cleat for fixing etc. complete all as specified 72 S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (For sliding window ) 73 M&L sheet glass 4.0mm thick figured glass, pin head type and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed 74 M&L for vetrified ceramic tiles 10mm thick full body(Dark shade/Ultra Charged/Double charged ) (square/rectangular) polished, area of each tilesexc 1.00 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 75 M&L for vetrified ceramic tiles 10mm thick full body(lightshade ) (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 76 S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediatechannel at 457 mm centre to centre and including Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified 77 S&F for 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish(Frame work for ceiling shall be measured and paid separately) 78 Removal of existing Rifle racks including all fixing stell bolts and cement work all as specified work 79 M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified 80 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 81 M & L for 25mm thick PCC 1:2:4,type B-0, (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing the surfacesrough to receive screed bed complete as specified and directed. 82 M&L for machine cut mirror polish kota stone slab flooring 20-25mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 83 M&L for machine cut mirror polish kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10mm thick cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 84 Fixing and grouting of new steel Rifle racks on the floor including necessary fixing bolts and necessary arrangements of grouting and grouting material all as specified. 85 M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 86 S&F for Mild steel ,plain black sheet of minimum 0.8mm thickness for Hoods cover for Rolling shutters;cladding to door shutters/Hangar doors ; water tank platforms etc with plain 40mm lap joints or welded/riveted seams including ,bending, turning up, mitred angles , stopped ends,outlets,etc. as required all as sprcified and directed by Engr-in Charge. 87 M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. 88 Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. including sorting out serviceable and unserviceable light fitting and keep serviceable fitting in safe guard for reuse as required on site. 89 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 90 Taking down cearfully byunscrewingthe unserviceable DB Boxes, MCB distribution boards SP & TPN with porcelain cutouts etc all as directed. 91 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and capingwith all fittings/fixture etc andsurface typePVC box, cover plate all as specified and directed by Engr-In-Charge.(a) Onelight point controlled by one switch. 92 (b) One 3 pin socket 5 A on independent board. 93 (c) One 3 pin socket 5 A on same board. 94 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,with all fittings/fixture etc andsurface typeModular , PVC box cover plate, frame all as specified and ndirected by Engr-In-Charge. 95 S & F Sub Main Wiringwith FRLS PVC Insulatedmultistranded copper conductorwires ofsize2x6.0 sq. mm + 1x6.0 sq. mm earth wire in casing caping complete as directed.Note : for Item No 95 One run of phase wire one run of Neutral wire and one run of Earth wireand one run of casing and capping shall be meassured and as one length. 96 S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps.including fixing concealed in wall and making good the disturbed surfacecomplete all as directed 97 Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 98 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connections as directed 99 S&F MCB SP 240 volt 6 to 32 A C series complete 100 S &F for MCB SPN 40-63 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. 101 Supply and fix Modular switch 1 way 6A, 1 module 102 Supply and fixmodular Socket, 6A - 2/3 pin combined 2 moduler 103 Supply and fixModular switch 1 way 16A, 1 module 104 Supply and fixmodolar Socket 6A/16A - 2/3 pin combined2 module, 105 Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm 106 S & F Modular white cover plate with frame 2 Module 107 S & F Modular white cover plate with frame 3 Module 108 S & F Modular white cover plate with frame4 Module 109 S & F Modular white cover plate with frame 6 Module 110 S & F Modular white cover plate with frame 8 Module 111 Supply, Fixing , Testing and Commissioning of Single phase isolation transformer to be installed at input power supply of L-2 switch,via 16 Amps MCB and with power earthing point specification as follows 1Ph, Capacity 1KVA, Input 230V AC ±10%,Output 230V±10%,50 Hz,cooper wire,work efficiency more than 95%,potential between earth to neutral less than 1 Volt with all standard fitting as per direction of Engineer in charge 112 Supply, Fixing , Testing and Commissioning ofIsolation transformer of capacity 5 KVA, single phase ,50 Hz , Copper wound , Air cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 240+-5% and output voltage range 240+-5% ,Ratio 1:1 , indoor , efficiency more than 95 % , Potential difference between neutral to earth less than one volt with all standard fittingsas per direction of Engineer in charge 113 Supply, Fixing , Testing and Commissioningof Three Phase Surge Protector Device to be installed at input power supply of L-2 switch all as specified and directed by Engr-In-Charge 114 S&F wall mounted Industrial grade metal enclosure box made from 3mm thick CRCA sheet consist of following Items:-(a) Panel mounting Industrial grade socket/plug outlet 16 A,IP44(b) SPD ,1.5kv,320A,20kA - 1 Nos(c ) MCB SP 16 A- 1 Nos 115 S&F Vertical double door Distribution board TPN 4 way 125 A rated busbarconsisting ofMCCB. 63 A 18KA - 1 Noincluding fixing on wallsurface and making good the disturbed surfacemaking all nacessary incomming and out going connections using proper size copper thimblescompleteall as required on site all as directed 116 Supply and fixing in replacement sheet metal enclosure with DBs ( grouted in walls) double door type for MCBs 12 ways with 200 Amps 240 volts rated bus bar incl taking down old DB all as specified. 117 Material and labour for taking down serviceable Fire Alarm panel from one location and re-install the same at same /another location including fixing brackets/nut bolts incl testing and commessioning of the same all as specified and directed 118 Material and labour for taking down serviceable Smoke / Heat / Fire detector from one location and re-install the same at same /another location including necessery cable upto Fire alarm panelincl testing and commessioning of the same all as specified and directed 119 Supply and fix adressable smoke Detectors Complying with and type certified to EN-45 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 all as specified. 120 Supply, install, testing and comissioning of adessable break glass manual call pointincluding sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete. 121 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade. 122 Material and labour for taking down serviceable split AC of capaicty upto 2.0 TR from one location and re-install the same at same /another another location including fixing brackets, gas charging, brazing and additional required copper piping incl testing and commessioning of the same all as specified and directed 123 Supply, Install testing and commessioning Single pole and neutral enclosure 240 Volts with a two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed 124 Material and labour for providing point wiring with two runs of 4 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,ISI Marked complet for housing one 15 to 20 A Switch / socketscomplete 125 Supply, Install , Testing and Commissioning of wall mounted enclosure box made from 3mm thick CRCA sheet enclosure consist of following items for 3 Phase 2 AC timer & Controller of Auto switching timer unit suitable for operate 8.75 TR package type AC:-(a) Timer - 1 No(b) Contactor 32 amps - 2 No(c ) Indication lamp - 1 No
Contract Date: Jan 09, 2026 Contract Value : 44.46 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
29.
Civil Aviation #11209499 AOC
Bids Are invited for Operation and maintenance of Electrical and Mechanical installations - Operation and maintenance of Electrical and Mechanical installations of operational and non operational areas including Terminal buildling, ATS Building, Fire station, Electrical Substation and other ancillary buildings for round the clock operation on all days including Sundays and Holidays by engaging following manpower along with providing required tool and consumables as specified in special conditions of contract for day to day maintenance except spares. The job includes preventive, routine maintenance, attending complaint or fault or breakdown by taking rectification actionensuring serviceability and satisfactory working condition of the system, maintaining all records and documentation etc. complete as per agreement conditions and as per the instruction of EIC.1. Supervisor (Highly Skilled) - 01 no.2. Document Assistant (Highly Skilled) - 01 no.3. Wireman (Skilled) - 07 nos.4. Semi-skilled- 06 nos.5. Helper (Unskilled) - 03 nos.(The above manpower is excluding reliever) , Job contract for Operation and Day to Day Maintenance Services of Airport Systems equipments - Job contract for Operation and Day to Day Maintenance Services of Airport Systems equipments including SCCTV Camera System, FIDS , PA System, HHMD, DFMD, Security Equipments, BDDS equipments, XBIS machines, ETD Equipment etc. installed at terminal building, ancillary building at Rupsi Airport. Job also includes attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, providing registers and log books as per formats given in tender document and maintenance of daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, registers and log books and coordination with OEM Technicians during CMC works etc. by deploying following manpowers as per scope of work given in special conditions of contract shall be ensured round the clock (ie. in one shifts basis) on all days including Sundays & National Holidays as per direction of EIC and as per attached Annexure-A of ATC. 1. Supervisor (High skilled) -01 no. 2. Technician ( Skilled) -01 no. (The above manpower is excluding reliever) , Execution of item of Schedule of rates CPWD DSR 2022 as and when required - Execution of item of Schedule of rates CPWD DSR 2022 as and when required for attending breakdown, repair and maintenance and upkeep of internal & external electrical installations as per direction of E-I-C at different locations of operational and non operational area i/c Terminal Building, ATS Building, Fire Station, Electrical substation and other ancillary buildings etc. The bidder shall quote the rate in INR only including price escalation for 01 year for the job corresponding to an amount of Rs. 1,00,000.00 (including GST from DSR 2022 items) and percentage (%) above/below shall be calculated by AAI and paid accordingly. , Testing of Transformer oil sample including conducting BDV test and submission of test report etc complete as required - Testing of Transformer oil sample including conducting BDV test and submission of test report etc.complete as required , Filtration of Transformer oil of 630 kVA transformer - Filtration of Transformer oil of 630 kVA transformer to attain acceptable di-electric strength by hot streamline process including arrangement of plant/machine, transportation etc. complete as required by topping of Transformer oil and BDV testing including submission of test reports before & after dehydration of oil. (excluding cost of Transformer oil) (Item is to be executed if the BDV value of transformer oil is found below the stipulated value). , Servicing and Checking of LT Air Circuit Breaker - Servicing & Checking of LT Air Circuit Breaker (ACB) of L&T U POWER OMEGA make by deploying Authorised Service Personnel of Manufacturer/ OEMs Service Dealers as per OEMs standards complete as required and submission of service reports. , Servicing and Checking of HT Vacuum Circuit Breaker - Servicing & Checking of HT Vacuum Circuit Breaker (VCB) of Siemens make by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports. , Calibration and testing of relays at HT Panel - Calibration and testing of following relays at HT Panel by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports.i) Vamp 57 - 5 Nos. (Numerical type of Schneider Make)ii) VAJH13 - 5 Nos. (Tripping Relay of Alstom Make)iii) VAX31 - 5 Nos. (Trip Circuit Supervision Relay of Alstom Make)iv) VAA33 - 4 Nos. (Auxiliary Relay of Alstom Make) , Calibration and testing of following relays at LT and Synchronizing Panel - Calibration and testing of following relays at LT & Synchronizing Panel by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports.i) VAJH13 - 2 Nos. (Tripping Relay of Alstom Make)ii) VAX31 - 2 Nos. (Trip Circuit Supervision Relay of Alstom Make)iii) CCUM21PF112A - 2 Nos. (Definite Time Reverse Power Relay of Areva Make)iv) CAG14AF15A - 2 Nos. (Instantaneous Earth fault Relayof Alstom Make) , Scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting - Scrubbing, cleaning the existing surface of cubicle panel, feeder pillars & painting the same with one coat of primer and one coat of synthetic enamel paint of approved colour etc. complete as required , Lettering of maximum 2 inch size Alphabetic or numerical - Lettering of maximum 2inc size (Alphabetic / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. complete as required. , Cleaning the surface of MS chequered plates - Cleaning the surface of MS chequered plates and painting with one coat of primer and two coats of synthetic enamel black paint etc. complete as required. , Supply and replacement of silica gel in breather of existing 630 KVA transformer etc. complete as required , Lifting and lowering of 10 HP borewell submersible motor pump set - Lifting and lowering of 10 HP borewell submersible motor pump set along with dismantling of complete delivery pipeline, removal of pump sets, disconnection of flexible submersible cable, reassembling of submersible pump, complete delivery pipeline, fixing / laying of existing submersible cable including electrical connection, testing and commissioning etc. complete as required. , Servicing and complete overhauling of 10 HP borewell submersible motor pump set - Servicing and complete overhauling of 10 HP borewell submersible motor pump set including replacement of defective bearing, coupling, impellar, mechanical & oil seal, heat varnishing of motor etc. complete as required , Decoration of Terminal Building and Canopy of Rupsi Airport - Decoration of Terminal Building and Canopy of Rupsi Airport, in Tri-Colour, with the following lighting items of pattern approved by E-i-C or his authorized representative, for 03 days etc. complete as required.i) 60 nos. LED series lighting chain (minimum chain length 5m and uniform spacing between chains not more than 0.75 m)ii) 20 nos. RGB LED Facade/ Disco/ Flood light fittings (minimum 10000 lumen output) , Supply and replacement of defective smoke detectors - Supply and replacement of defective smoke detectors of suitable make & model compatible to theexisting system. , Supply and replacement of defective manual call point - Supply and replacement of defective manual call point of suitable make & model compatible to the existing system , Supply of convertor or driver suitable for PHILIPS make 20 W downlight types LED luminaires or fittings - i) PHILIPS make 20 W downlight Type DN195B LED20S , Supply of convertor or driver suitable for OSRAM make 120W types LED luminaires or fittings - ii) OSRAM make 120W Type. LEDENVO LED Street Light , Supply of convertor or driver suitable for HAVELLS make 18 or 20 W downlight types LED luminaires or fittings - iii) HAVELLS make 18/20 W downlight , Supply of convertor or driver suitable for WIPRO make 36W 2ftx2ft recess mounted fitting - iv) WIPRO make 36W 2ftx2ft recess mounted fitting , Supply of 1000W 240V Lamp suitable for Aerodrome Beacon - Supply of 1000W , 240V Lamp suitable for Aerodrome Beacon of model AB-1000F Make- Manairco Inc as and when required. , Supply of Aerodrome Beacon - Supply of Aerodrome Beacon of model AB-1000F Make- Manairco Inc as and when required. , Calibration of Clinometer - Calibration of Clinometer from Govt. Test laboratory/ OEM, submission of test report etc., complete as required i/c taking the equipment from AAIs site to laboratory and bringing back the same from laboratory to AAIs site. , Supply of reflector suitable for AMA make PAPI - Supply of reflector suitable for AMA make PAPI fittings as and when required. , Supply of 2C x 4 sq mm. Secondary lead with Plug - Supply of 2C x 4 sq mm. Secondary lead with Plug at one end of standard length of 5 m as and when required , Supply of B connector or four way porcelain terminal - Supply of B - connector / four-way porcelain terminal for AMA make PAPI units as and when required , Supply of 5 kV grade 50 Hz AC Isolating Transformer - Supply of following rating 5 kV grade, 50 Hz AC Isolating Transformer, series type, encapsuled inpolyster resin, finally moulded in neoprene type rubber with primary and secondary leads, confirming to latest specifications as required suitable for airfield lighting applications etc. as and when required. 200 Watt, 6.6/6.6 Amp. , Supply of two pin halogen lamp Holder suitable for 200 Watt - Supply of two pin halogen lamp Holder suitable for 200 Watt, 6.6 Amp Lamp as and when required. , Supply of 5 W Screw Cap LED lamp - Supply of 5 W Screw Cap LED lamp suitable for Landing T , efficacy not less than 100 lm/W as and when required. , Supply of Wind Sock Cloth - Supply of Wind Sock Cloth, 13 ft 9 inch length, colour preferably Orange & White and conforming to ICAO Annex-14 as and when required. , Supply and replacement of LED flood light - Supply and replacement of LED flood light for mounting on Wind Direction Indicator, equivalent to Philips make Model BVP132LED16/CW 20W 100-240V WB IN as and when required. , Supply and replacement of Obstruction Light of Wind Direction Indicator - Supply and replacement of Obstruction Light of Wind Direction Indicator as and when required. , Supply and replacement of 180 AH 12 V Lead Acid battery - Supply and replacement of 180 AH 12 V Lead-Acid battery, conforming to IS 14257 1995 with up to date amendments, suitable for high cranking performance of 400 kVA DG set as and when required. , Supply and replacement of 100 AH 12 V Lead Acid battery - Supply and replacement of 100 AH 12 V Lead-Acid battery, conforming to IS 14257 1995 with up to date amendments, suitable for high cranking performance of 62.5 kVA DG set as and when required , Supply of Automaic Electric Hand drier - Supply of Automaic Electric Hand drier of following specifications or equivalentMake OMCO, Model IPX1,Voltage-220-240V, Power 1800W , Servicing, Checking Repairing Overhauling and Testing of CROMPTON make 630 KVA Transformer - Servicing, Checking, Repairing, Overhauling and Testing of CROMPTON make 630 KVA, 11/0.433 KV Transformer including carrying out the following tests by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of reports.a) General inspectionb) IR value test primary to secondary, primary to earth, secondary to earthc) Votage ratio check at all tap position,d) Buchholz relay operatione) OTI operationf) WTI operationg) On-Load Tap changer operation checkh) Cleaning of transformer and replacement of silica geli) Acidity Check test of Transformer Oil. Total Quantity : 599
Contract Date: Ref. Documents Contract Value : 92.89 Lakh
Boards / Undertakings / PSU No of Bidders 7
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 12,192
Government Departments No of Bidders 2
33.
Power #11176094 Price Bid
Tender for Supply Of Electrical Items And Stores Hardware Items For Sub-Transmission Division-Ii, Jpdcl, Jammmu For The Year 2026-27 , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Termination Connector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks. A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocb Bicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocb Crompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , J) Male Contact For Ocb Mei Make (With Silver Coating) , K) Female Contact For 11 Kv Ocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kv Ocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) annual rate contract Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45....65 Hz, With Rs485 Output, Aux Voltage: 1260V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii) 750/375/5-5-5 , Iii) 600/300/5-5-5 , Iv) 600/300/5-5-5 , V) 400/200/5-5 , Vi) 300/150/5-5 , Vii) 150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulators Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor (Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsr Panther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsr Wolf Conductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsr Dog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One) With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 annual periodical maintenance , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based (Abc Type) 4 Kg. , C) Power Based (Abc Type) 6 Kg. , D) Power Based (Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 annual periodical maintenance (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 annual periodical maintenance (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 annual periodical maintenance (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 annual periodical maintenance (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank & Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cells Complete With All Accessories , 30V, 25A Battery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 annual periodical maintenance Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( detail project report 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make, Model: 30V Dc Dcps, Smps Based Dc Power System. , Main Control Card Suitbale For Use In - Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dc Boost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm Φ (1½) , E) G.I. Pipe 50 Mm Φ (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendments Up To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 Mω (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banks Apfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/√3/110V/√3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain) , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 11Kv Pt Indoor Type Resin Cast 11 Kv/110V (3 Nos) , 11Kv Pt Draw Out Type Along With Housing 11 Kv/110V (1 Complete Set) , 11 Kv Vaccum Interrupter Type Vge4 Abb Make For Pascal Vcb , 11 Kv Vaccum Interrupter Stelmac Make , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Electricfield , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Pascal , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Stelmac , Spring Charge Motor For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Stelmac , Micom Alstrom P14n Relay With 61850 Scada Compatibale Port , Ashida Make Relay Adr 241B With 61850 Scada Compatible Port , Ashida Make Relay Adr 241A Non Scada , Ashida Realy Adr 141C , Master Trip Relay Alstrom Make , Led Indicator 36 V Dc , Ethylene Propylene Rubber (Epr) Self Amalgamating Tape 38Mmx9mtr Scapa/3M , Ampere Selector Switch , 66 Kv Disc Insulator B&S Type Polymer , 66 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , Battery Charger Automatic Float-Cum-Boost Charger Input 190-230 V Ac 1Ph, Output 30 V Dc 25 annual periodical maintenance With Full Wave Rectification, Output Float Voltage: 33.0 Vdc Output Boost Voltage: 35.0 Vdc With Test Report. , Frp Extendable Ladder Of 10M , Polywater® Powerpatch® Transformer Seal And Pilc Cable Repair Allow For The Repair Of Active Leaks In The Field , Wrist Type High Voltage Detector , Hydraulic Crimping Tool Upto 630 Sq Mm Size , Digital Earth Clamp Tester , 60 Kv Motorised Oil Bdv Kit , Switch Disconneter Fuse 160 A , Mcbs 63A , 9 Mtr. St Poles , 11 Mtr. St Poles , 13 Mtr. Poles , Gaskets Of Of All Sorts For Power Transformer , 33 Kv Frp Crossarm , Frp Channels Of (100X50x6) Mm , Frp Angles Of (65X6)Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
35.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 3.39 Lakh
Boards / Undertakings / PSU No of Bidders 5
Maharashtra View Result →
37.
Housing Urban and Rular Development #11132405 AOC
Tender For Special Renovation Of Electrical Installation Work At Old Hospital Building (Inside And Outside) Of Mathabhanga Sd Hospital, Mathabhanga In The District Of Coochbehar. - 1 Dismantling the existing electrical appartus like distribution wiring, TL fittings, ceiling fans, power board, DB, LT Panel etc from its position and deposite to the safe place as per direction of EIC. 2 SUB-HEAD 1--Distribution WiringDistribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish 3 Average run 8 mtr 4 Average run 10 mtr (For Emergency Light point Only). 5 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 2 nos 5A 3 pin flush type plug socket & 2 nos Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish 6 Average run 6 mtr 7 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25/32 mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required 8 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 9 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 10 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) 11 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC 12 Supplying and Drawing 1.1 KVsingle core stranded FRPVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 13 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC 14 Supplying and fixing PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 15 25mm size 16 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 17 2.5sqmm 18 4 sqmm 19 6 sqmm 20 10 sqmm 21 16 sqmm 22 SUB-HEAD 2-- PLUGS & SOCKETSSupply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 23 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. 24 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 25 175 mm x 100 mm x 65 mm 26 200 mm x 150 mm x 65 mm 27 240 mm x 200 mm x 65 mm 28 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 29 175 mm x 100 mm x 65 mm 30 200 mm x 150 mm x 65 mm 31 240 mm x 200 mm x 65 mm 32 SUB-HEAD 3--BDB,PDB,VTPN ETCSupplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make: L&T/ Legrand /ABB/ SIEMENS/ Schneider] 33 6 way (upto 160A) 34 Supplying and fixing double door Horizontal 6 way TPN MCBDistribution board with IP-42/43 protection, on surface of wall by clamp arrangement & mending good the damages to original finish incl. cable end box and Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment[Make: L&T/ Legrand /ABB/ SIEMENS/ Schneider] 35 6 Way 36 Supplying and fixing double-door SPN MCB Distribution Boardwith IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: L&T/ Legrand /ABB/ SIEMENS/ Schneider] 37 2+10 way 38 Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection [Make: L&T/ Legrand /ABB/ SIEMENS/ Schneider] 39 100 A, FP 40 Supplying and fixing 240/415 V MCCB/MCB Isolator on din rail of existing DBs and necessary connection.[Make: L&T/ Legrand /ABB/ SIEMENS/ Schneider] 41 415V, 63 A FP 42 240V, 32 A DP 43 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make: L&T/ Legrand /ABB/ SIEMENS/ Schneider] 44 63A TP MCB 45 6-32 SP MCB 46 Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment 47 6 way VTPN 48 Supplying and fixing 415V, on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc[Make: L&T/ Legrand /ABB/ SIEMENS/ Schneider/ Havells /HPL /Standard] 49 63A TPN with fuse on L&N 50 100/125A TPN with fuse on L&N 51 SUB-HEAD 4--Supplying & Laying of CableSupply of2/4 Core XLPEInsulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] 52 4 CORE 50 SQMM (from panel to100AVTPN) 53 4 CORE 70 SQMM (from panel to125A VTPN) 54 4 CORE 120 SQMM (from Gr Floor panel to 1st & 2nd floor Panel) 55 Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. 56 Up to 50 sqmm 57 From 70sqmm to 150sqmm 58 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 59 4 CORE 50 SQMM 60 4 CORE 70 SQMM 61 4 CORE 120 SQMM 62 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 63 4 CORE 50 SQMM 64 4 CORE 70 SQMM 65 4 CORE 120 SQMM 66 Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.(i) With out angle iron support 67 150x50x1.25mm (18SWG) With out angle iron support 68 200x50x1.25mm (18SWG) With 25x25x3mm angle iron support 69 300x50x1.25mm (18SWG) With 25x25x3mm angle iron support 70 Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 71 150x50x1.25mm (18SWG) 72 200x50x1.25mm (18SWG) 73 300x50x1.25mm (18SWG) 74 Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 75 150x50x1.25mm (18SWG) 76 200x50x1.25mm (18SWG) 77 300x50x1.25mm (18SWG) 78 Supply & Fixing of perforated GI cable tray cross member with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 79 200x50x1.25mm (18SWG) 80 300x50x1.25mm (18SWG) 81 Supply & Fixing of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the reducer incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 82 150x50x1.25mm (18SWG) 83 200x50x1.25mm (18SWG) 84 300x50x1.25mm (18SWG) 85 Supply & Delivery of1.1 KV grade, XLPE insulated & Sheathed, multi stranded, armoured, 4 core 240 sq. mm. Al conductorcable. [Make- Havells / Polycab/ Gloster / RR Kabel/RR Kabel] (DG to AMF) 86 Supply and Delivery of 4 feet, 240V, 40 W integrated type single LED tube fittingwith glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 87 Supply and Delivery of 4 feet Industrial box type twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 88 Supply & Delivery of 240V recess mounted 2x2 LED downlight having following wattage in white powder coated pressure die cast aluminium housing , with glare free uniform illumination, suitable for 2 x 2 grid ceiling with CCT (5700K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 89 36 Watt 90 Supply & Delivery of 240V surface mounted 2x2 LED downlight having following wattage in white powder coated pressure die cast aluminium housing , with glare free uniform illumination with CCT (5700K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 91 36 Watt 92 SUB-HEAD 6-- FIXING OFLIGHT FITTINGSFixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastener and middle portion connected with the conduit with suitable size of clamping arrangments incl. S&F EI conduit, “U” type (50mmx100mmx50mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 93 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener 94 Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 95 SUB-HEAD 7 -- SUPPLY OFFANSSupply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories. (Make- Crompton / Usha / Orient/ Polar) [BEE star rated] 96 Sweep Size- 1200 mm (48), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M 97 Supply & Delivery of 230V, 50Hz, 450 mm sweepheavy duty full metal body wall bracket fan having wattage ≤ 90 Watt, RPM ≤ 1325, Air Displacement (In CFM) ≥ 3550 complete with all accessories. (Make - Orient/Crompton/ EPC/Cinni) [BEE star rated] 98 Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [BEE star rated] 99 300 mm (12), 4 Blade, RPM ≤ 920 , Wattage ≤ 45 Watt, Sound level ≤ 46 dB, Air Displacement (In CFM) ≥ 750 100 SUB-HEAD 8-- FIXING OFFANSSupplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40mm x 9mm MS flat including making good damages to building roof with satisfactory finishing and painting - (As per Drawing no. 475 of PWD Specification Book - May 1991) 101 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. 102 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. 103 Fixing only cabin fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length 104 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 105 30 cm (12) 106 Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 107 30 cm Exhaust fan (12) 108 Supply & Fixing of fan down rod (14 SWG-White MS pipe zins plated) having 19 mm OD 1.8 +/- 0.05 mm thick complete with cutting, making holes for fixing the fan incl. necessary connection wire (2x1.5 sqmm cu wire) as per direction of EIC. 109 SUB-HEAD 9-- Miscellaneous WorkSupply & Fixing240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plateflushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 110 Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixedpaint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paintUpto 9.0 mtr. long pole 111 (i) 1st coat of aluminium paint over 1 coat of RO priming 112 (ii) 2nd coat of aluminium paint over 1st coat 113 SUB-HEAD 10-- EarthingExcavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) 114 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: 115 By ISI-Medium GI pipe 116 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required 117 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 118 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 119 Extra for treatment of soil by using salt & charcoal or coke for plate electrodeRef:- 120 Sub-Head 11- SITC of FDS systemSITC of Intelligent addressable fire alarm system with FACF, detectors, MCP, sounders with all accessories & wires including testing and getting statutory approvals. 121 Sub-Head 12- SITC of LT PanelSupply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. 122 Construction Details :All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side. 123 Incoming Arrangement :a)415 Volts, 200 A,TPN SFU with proper HRC fuse (open execution type)(Make: L&T/Legrand/Schenider/ABB/Siemens)- 2 No. 124 b) 415 Volts, 200 A, on load front operatedTPN changeover switch (open execution type) (Make: L&T /Legrand/ Schenider /ABB /Siemens)- 1No. 125 Bus bar section :415 V, 315 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus barmounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification- 1 set. 126 The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications. 127 Outgoing Arrangement :a) 415V 125 Amps TPN SFU units with HRC fuses(Make:- L&T/SIEMENS/ABB/ SCHNEIDER)in openexecution.---- 2 No. 128 b) 415V 100 Amps TPN SFU units with HRC fuses(Make:- L&T/SIEMENS/ABB/ SCHNEIDER)in openexecution.---- 4 No. 129 c) E.I. Danger Board of suitable size ------- 1 no. 130 Metering Panel:-a) Digital multifunction meter with selector push button switch (up/down) with Voltage, Current, Frequency, Total Harmonic Distortion, PF, KW, KVA, Kwh, KVAh and Preloaded Max & Min Demand with Date & Time Stamping display (Make-Schneider Electric/ Cat No- EM6400NG Class accuracy CIo.5S, POP of Accuracy Class 0.5S or equivalent model of Legrand/ Siemens/ L&T) - 1 No. 131 b) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Siemens cat.no 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent cat of L&T/ABB/ SCHNEIDER) - 1 No. 132 c) 500/5 Amp ratio C.T (Kappa or equivalent) --- 3 nos. 133 d)S & F 2 Amp SPMCB for auxiliary supply to meters (Make- SIEMENS/L&T/Legrand) - 1 no. 134 Interconnection :-All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with propersocketing of the end of each wire leads. 135 Earthing Arrangement :-A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size G.I. strip. 136 The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. 137 Installation :-The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. 138 ADD GST @ 18.00% ON SUM OFAMOUNT Sl-01 to SL-56.16 i.e 18% on Rs. 3067380.00 139 ADD Cess @ 1.00% ON SUM OFAMOUNT Sl-01 to SL 57 i.e @1% on Rs.3619508.00
Contract Date: Oct 14, 2025 Contract Value : 33.57 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
39.
Housing Urban and Rular Development #11116820 AOC
Tender For Proposed Furniture For Upgradation Of 30 Bedded Hospital To 50 Beded Hospital Sub District Hospital At Atpadi Tal-Atpadi Dist-Sangli.-1 Providing & fixing wall paneling in 19 Milllmetre and & 6 Millimetre thick Plywood finished with 1 Millimetre laminate for all exterior sides, with approved shade as per detailed drawing & design.SS hinges.SS handies. TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 2 FULL HEIGHT PARTITION - Providing & fixing wall partition made in 19+19 Millimetre ply frame work, 9 Millimetre thick Plywood finished with1.00 Millimetre laminate for all exterior sides with approved shade and 12 mm glass fixed on teak wood beading as per detailed drawing & design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood - BWR IS303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge.) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 3 LOW HEIGHT PARTITION - Providing & fixing 75 Millimetre thick Partition using 50 Millimetre thick Plywood having 12 Millimetre thick Plywood for both sides. Partition Should for Frame having Finished with 1.00 Millimetre thick laminate, 12.00 Millimetre thick Clear glass with necessary fixtures to be provided as directed etc. complete. As per detailed drawing and design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design.Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 4 Storage - Providing & fixing Stoarage USING 19 Millimeter thick BWR plywood IS 303 standerds empowerd with antitermite anti fungus chemical plywood for structure 6 mm Plywood for back. 25 mm thick block board full pinn BWP door should finish with handles 12 stainless stell & mortice locking arrangement . All exterior surfaces should finished with 1.00 Millimeter laminate and internally finished with mm thk. while laminate storage should have handles locking arrangement etc. complete as per detaile drawing and design .(Depth of Storage 0.45 meter).with all necessary fixture and fastenings etc complete.( Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 5 Entrance Door - Providing & Fixing Sandwiched doors for cabin using 19+12 thick ply for both sides should finished with 1.00 mm thick laminate. All exterior faces should coverd with T.W. beading doors should have 6 mm thick clear glass S.S. Handle, Lock, Stoppers and Hydraulic door closer etc.complete. SS hinges , SS handles , TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS 303 Standards empowerd with antitermite anti fungus chemical. (Before execution sample should be get approved from engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 6 Prownling and Fixing Service Counter made up by 19mm thick Plywood structure, lack and tops. All plywood surfaces finished with 1.00 mm thick Lantinate, Counter should Square have two tops, drawers, storage and keyboard thaye having necessary fittings like hinges, handdles and locking arrangement etc. complete as directed SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 7 Providing & fixing Officer table of size 1.5*0.75*0.75 meter using 25 mm thick for top & 19 mm for sides. externally finished with 1.00 mm thick laminate and internaly finished with 2.00 mm thk. white laminate Table should have side table of size 1.40*0.40 meter with drawers and doors, locking arrangement, footrest, keyboard tray of size 485*180mm & cable manger etc. complete. As per detailed drawing and design. Plywood-MR Grade 100% BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 8 Staff / Clerk Table - Providing & fixing Officer table of size 1.37*0.60*0.75 meter using 25 mm thick for top & 19 mm for sides. externally finished with 1.00 mm thick laminate and internaly finished with 2mm thk. white laminate Table should have side table of size1.40*0.40 meter with drawers and doors, locking arrangement, footrest, keyboard tray of size475 X 180mm & cable manger etc. complete. As per detailed drawing and design. Plywood-MR Grade 100 % BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 9 Providing & fixing Executive table of size 1.80*0.90*0.75 meter using19+19 Millimetre thick Plywood for top & 19+12 Millimetre for sides. Externally finished with Imm thk laminate & internally with Imm thk white laminate respectively. Table should have side table of size 1.50*0.40 meter with drawers and doors, locking arrangement, footrest. keyboard tray of size 485*180 Millimetre & cable manger ete, complete. As per detailed drawing and design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood - BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 10 MS Rack -Providing and fixing mild rack of TCPC satara make Cat no Msrk -1 or equivalent make having overall size 1.80 meter x 0.90 meter x0.40 meter. Including five rack and four side anfle of approved size as per detailed drawing and design including all necessary etc. complete and as directed by engineer incharge. Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 11 Providing and arrangemnt of high back chair, synchronized mechanism with multiple locking, adjustable armrest, gaslift for seat height adjustment, standard 5-prong P/Nylon base with leatherite upholstery. 12 Providing and arrangemnt of mid back chair, normal synchronized mechanism, fixed armrest, gaslift for seat height adjustment, standard 5-prong nylon base with leather upholstery. 13 Providing and arrangemnt of mid back chair, ECO CTS mechanism, fixed armrest, gaslift for seat height adjustment, standard 5-prong P/Nylon base with fabric upholstery. 14 Providing and fixing 3 seater public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 15 Providing and fixing sofa set 3+1+1 brown and cream leather Dimensions - length 182.5 centimetre, breadth 100 centimetre, height 100 centimetre, weight - 66 kg. Seating capacity - five seat. 16 Providing and fixing rollar blinds of approved make and shade of 38 milimetre round aluminium channel with blackout fabric and telting with chain (ball) system with all necessary fixtures and fitting, excetra complete. 17 Providing and fixing false ceiling with eco-friendly light weight calcium silicate tiles of spintone surface texture “aerolite” make or equivalent of size 595 milimetre X 595 milimetre having 15 milimetre thick densified micro look edge and 100 percent humidity resistance incombustible as per BS 46 part IV and thermal conductivity 0.043 w/m0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600 milimetre X 600 milimetre made from hot dipped galvanised iron steel sections ion silhouette profile, rotary stitched double webbed white with 6 milimetre reveal profile (white/black), wherein, main “T” runner of size 42 milimetre X 14 milimetre between main tee 600 milimetre center to center and secondary cross “T” of size 33 milimetre X 14 milimetre X 0.43 milimetre thick of length 600 milimetre long spaced inter-locked at middle of the first crossed “T” in each panel to form grid of 1200 milimetre X 600 milimetre resting on periphery wall Profile wall section 19 milimetre (7+7) X 19 milimetre X 0.40 milimetre thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, smoke detectors excetra, wherever required. Main “T” runners suspended from ceiling with using galvanised iron soffit cleats of size 25 milimetre X 35 milimetre X 1.6 milimetre of required length fixed to the ceiling with 6 milimetre diameter and 50 milimetre long dash fastener, 4 milimetre diameter galvanised iron adjustable rods with powder-coated / good quality galvanised iron level adjustment clips of 35 milimetre X 35 milimetre X 0.8 milimetre spaced at 1200 milimetre center to center along main “T” all complete at all heights as per the specifications, drawings and as per the directions of Engineer In-charge. (For Ground Floor) 18 Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed / fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 X 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts excetra all complete. (For Ground Floor) 19 Providing & fixing Shutters for existing in-built storage made in 19+19 Millimetre ply frame work,19+6Millimetre thick Plywood finished with 1.00 Millimetre laminate for all exterior sides with approved shade using necessary hardware teak wood lipping and etc. as per detailed drawing & design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 20 Providing & fixing Computer table of size1.20*0.60* meter using 25 mm ply for top & 19 mm thick ply for sides. Internally and externally finished with ?.?? mm thick laminate & internally with 1mm white laminate respectively. Table should have ebco keyboard of size 485*180 mm including necessary hardware, teak wood Lipping etc. complete. per detailed drawing and design.SS hinges, SS handles, lipping etc. coniplete. As per detailed drawing and design. Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should get approved from Engineer In charge) Rate Approved S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 21 Detearmination of resistance to dry heat, determination moisture content, determination of density,thickness plywood 22 Test for glue adhesion
Contract Date: May 19, 2026 Contract Value : 1.79 Crore
Government Departments No of Bidders 2
Maharashtra View Result →
40.
Power #11110319 Technical Bid
Tender for Rate Contract For Procurement Of Material That May Be Required During The Emergencies For The Year 2026-27 In Respect Of Ed-3Rd , Supply Of , 50 Mm² Ab (Ht) Cable (3X50 + 1X70 Mm²) Xlpe(11 Kv, 3C + Earth) , 70 Mm² Ab (Ht) Cable (3 X 70 + 95 Mm²) Xlpe(11 Kv, 3C + Earth) , 120 Mm² Ab (Ht) Cable (3X120 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 150 Mm² Ab (Ht) Cable (3X150 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 185 Mm² Ab (Ht) Cable (3X185 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Upto 50- 95 Sqmm ( 3 Core) , Heat Shrinkable Outdoor Cable Termination Kit Above 120 To 185 Sqmm ( 3 Core) , Mid Span Straight Through Jointing Kit For 11 Kv Abc 120 -185 Sqmm , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 95 Mm² Ab (Lt) Cable ( 3 X 95 + 1 X 16 + 1 X 70 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 16 + 1 X 70 Mm²) Xlpe (1.1Kv, 3+1 C, Al) , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 95-150 Sqmm , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 35-70 Sqmm , 70 Mm² Single-Core Cable, 1.1Kv Grade, Xlpe Un-Armoured Frls Type , 95Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 120 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 150 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 185 Mm² Cable, 1.1Kv Grade, Xlpe Un Armoured Frls Type , 240 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 300 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 400 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 500 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 630Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 10 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 10 Mm² Cable (4C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (4C),1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 25 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , 35 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , Single Core 1 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 1.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 2.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 4 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 6 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , 11 Kv, 3- Core Xlpe 35 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 50 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 70 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 120 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 150 Mm² Round Wire Armoured, Frls Cable , 11Kv, Three Core 185 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11 Kv, 3- Core Xlpe 240 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 400 Mm² Round Wire Armoured, Frls Cable , 11 Kv End Termination For 3C 120- 185 Mm² , 11 Kv End Termination For 3C 240 To 400 Mm² , 11 Kv Straight Through Jointing Kit Upto 50-95 Mm² , 11 Kv Straight Through Jointing Kit Upto 120-185 Mm² , 11 Kv Straight Through Jointing Kit Upto 240-300 Mm² , 11 Kv Straight Through Jointing Kit Upto 400 Mm² , Lt Distribution Box For 25 Kva Dtr With 40 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 25 annual periodical maintenance Mccb 3P 16 Ka/10 Ka 1 No. Each (=2No.) For Outgoing Circuits . , Lt Distribution Box For 63 Kva Dtr With 100 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 63 annual periodical maintenance Mccb 3P 16 Ka 1 No.S For Outgoing Circuits , Lt Distribution Box For 100 Kva Dtr With 160 Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 200 Kva Dtr With 315 annual periodical maintenance Mccb 3P 25 Ka For Incomer & 160 annual periodical maintenance Mccb 3P 16 Ka 3 No.S For Outgoing Circuits , Lt Distribution Box For 250 Kva Dtr With 400 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 160 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Temporary Lt Fuse Set For Distribution Transformers (Customised) As Per Kpdcl Drawing No. Ce/P&P/Drg/2023/Ltfs/001 (Enclosed) , 11Kv Polymeric Composite Disc Insulator 12Kv,Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm Nos , 11Kv Polymeric Composite Pin Insulator 12Kv, 5Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 16 Kn Polymer Shackle Insulator , G.I Mukey For Shackle Insulators With Bolt Of (50X8)Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 258 Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 369 Mm , 11 Kv Link Set Heavy Duty With Copper Blade Size Of 14 Inch, 50 X 6 Mm, Female Contact Of Copper 6 Mm Thickness, With Post Insulator Of 10 Kn , 11 Kv Go, Ab Switch 3-Phase, 3-Pole,200 Amp, Vertical Type Set , 11 Kv Horn Gap Fuse Set 3 Phase 200A Set , Pg Clamps For 30 Mm² Acsr Conductor , Pg Clamps For 50 Mm² Acsr Conductor , Pg Clamps For 100 Mm² Acsr Conductor , Suspension/Tension Clamp With Eye Hook , Gi Pole Support Clamp Including Gi Nut And Bolts For 11 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 9 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr With Size 50X 8X 328 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr Or 9 Mtr Plain Cement Concrete With Size 50X8x441mm , Cable Tie (Each Packet Contains 100 Nos.) , Cable End Caps , Insulating Piercing Connectors Of Sizes , 11 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 11 Kv Ipc For Covered Conductor To Covered Conductor Connection , 33 Kv Tension Clamps With Bail And Ipc (Insulation Piercing Conductors) , 33 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 33 Kv Ipc For cement concrete To cement concrete Connection , 33 Kv Ipc With Aluminium Bail For Earthing , Main Single Phase Service Distribution Box (Pole Db) Along With Mccb /Mcb As Per Rec Drawing. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Main 3 Phase Distribution Box Ip 54 (Pole Db) Made From 20 Swg Crca Ms Sheet By Deep Drawn Method With Powder Coating. Internal Size Of The Box Shall Be 225Mm X 285Mm X 120Mm Used For Connection Through Abc Line And For Giving Connections To The Consumers 3Phase-1 Incoming 4 Outgoing I/C- 1, O/G-2-4 (200 A, 0.415 Kv) For Ryb Phase. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Lt Line Spacers 3 P ,4 Wire , Lt Line Spacers 2 P ,3 Wire , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 3-Ø, 4-Wire Trivector Meter (Prodigy ) With Suitable Ring Type Ct 200 annual periodical maintenance (Net Meter Enabled) , Single Phase Smart Energy Meter 5-30 Amp/ 10-60 Amp, Dlms Complaint Of Accuracy Class 1.0 , Three Phase Smart Energy Meter 20-80 Amp/, Dlms Complaint Of Accuracy Class 1.0 , Polypropylene Weather Proof Outdoor Type Meter Box For Single Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For Three Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For 4 Single Phase Meter Along With Zinc Plated Clamps , Gi Barbed Wire For Anti Climbing , Danger Plates With Clamps , Anti-Climbing Device With Clamps , Cemical Earthing Complete , Earthing Mat (Gi Flat 50 Mm X8 Mm)/(75 X10)Mm/(75X8)Mm , Gi Pipe 40 Mm 3 Mtr Long For Earthing , Earthing Electrode ( 3M Long) 20 Mm Dia. , Gi Strip 25X3 Mm , Galvanized Earthing Strips 50Mm X3mm. , Red Oxide , Aluminium Paint , Galvanized Nuts And Bolts , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2No..), Anchor Plate (200X 200 X 6 Mm), Nut-Bolts, 2 No. Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (11 Kv) , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2Nos.), Anchor Plate (300X 300 X 8 Mm), Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (33 Kv) , Gi V Cross-Arm With Top Bracket Of Sizes , Gi Channel X-Arm And Braces Of Sizes , Gi Extension Riser Of Sizes , Gi Wire 6 Swg & 8 Swg , Guard Netting (For 52 Mtr Span) , Aluminium Jointing Sleeves 100 Sqmm , Aluminium Jointing Sleeves 50 Sqmm , Aluminium Jointing Sleeves 30 Sqmm , Suspension Fitting (2 Bolt) For 11 Kv Line , Tension Fitting (4 Bolt) For 11 Kv Line , Suspension/Tension Clamp With Eye Hook , Earth Wire 7/4 Sqmm , 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation, Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Service Pillar. , 3 Phase, 415V, 1No Of 250 Amps Incoming 3 Tp Mccbs (Breaking 36Ka) Fitted Withoutgoing 03 No 100 Amps Sp Mccbs, 1No.100Amps 3 Pole Mccb For Outgoing Lt Cables, Distribution Feeder Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 4P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Feeder Pillar. , Fire Extingiusher Co₂ Type Of 4.5 Kg Capacity For Control Room , 3 Sand Bucket Fire Extingiusher , Gum Boots With Steel Toe Of Sizes , Winter Jacket- Coat Ecc Consists Of Three Independent Components That Is Wind Cheater ( Waterproof ), Insulating Layer And Waist Coat ( Sleeve Less ), Three Layer Waterproof Breathable Fabric, Dual Shade Og/ White, Material Of Insulating Layer- 1. Batting Polyester, 100 Gsm, 2. Fabric Nylon Knitted Aluminized, 3. Fabric Nylon 75 Gsm White, Material Of Waist Coat- Double Layer Bonded Polyester Fleece , Safety Vest - Reflective Luminous Garments - High Visibility Warning Garments With Synthetic Slide Fasteners, Fluorescent Yellow, Width Of Retro Reflective Material For All Types Of Garments (Minimum) 50 Millimeter , Non-Contact Voltage Detector, Upon Detection, Tip Glows And Beeper Sounds, Cat Iv 1000 V For Added Protection, Expanded Range: 90 V To 1000 V Ac Or 200 V To 1000 V Ac, Battery Cell Operated (2 Aaa Or Standard), Voltbeat Technology And Continuous Self-Test , Safety Helmet- Quality Of Shell High Quality, High Impact, Light Weight,Tough, Conformity To Specification- Is 2925:Latest ,En 397 Certified , Safety Rubber Gloves Up To 15 Kv As Per Iec Standard , Safety Belt/Harness With Shock Absorber , Safety Shoes Of Sizes -Personal Protective Equipment - Safety Footwear As Per Bis Specification No Is 15298 ( Part 2 ): 2016, Toe Cap- ( Steel ) Metallic, Insole, Classification- Class I ( Footwear Made From Leather And Other Materials, Excluding All-Rubber Or All-Polymeric Footwear ) With Different Sizes, Slip Resistant- As Per Clause 5.3.5.4 Of Is 15298 ( Part 2 )- Slip Resistance On Ceramic Tile Floor With Nals And On Steel Floor With Glycerine. , 11 Kv Earthing/Discharging Rod (Set Of 3 Rods) Set With Minimum 20 Sqmm Cable And U-Clamp , Battery Operated 12 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Alumunium Ladder 2*15 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Aluminium Ladder 2*10 Ft Long, Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope , Bamboo Ladder 18 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Bamboo Ladder 20 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Wart Free Budloo Wooden Ladder 17 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Wart Free Budloo Wooden Ladder 20 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Telescopic Ladder 20 Ft Long, 6063 T5 Grade Of Aluminium , 150 Kg Load Capacity, Self Locking Mechanism, Anti-Skid Foot Caps , Hand Held Search Light Led Lamp, 100 Watt With Lithium Ion 3.7 V, 3.5 Ah, 500 Lux/100 Mtr With Lamp Life -50000 Hours, Ip 65, 12 Months Warranty , Hdpe Pipe Outer Dia 180 Mm Inner Dia 152 Mm For Laying Of 11Kv Xlpe Cable From Power Transformer To Control Room , Mccb - 200 Amps,36Ka,4P Adjustable , Mccb - 40 Amps,36Ka,4P Adjustable , Mccb - 63 Amps,36Ka,4P Adjustable , Mccb - 100 Amps,36Ka,4P Adjustable , Mccb - 160 Amps,36Ka,4P Adjustable , Mccb - 250 Amps,36Ka,4P Adjustable , Mccb - 400 Amps,36Ka,4P Adjustable , Mccb - 630 Amps,36Ka,4P Adjustable , Mccb - 200 Amps,36Ka,3P Adjustable , Mccb - 100 Amps,36Ka,3P Adjustable , Mccb - 160 Amps,36Ka,3P Adjustable , Mccb - 250 Amps,36Ka,3P Adjustable , Mccb - 400 Amps,36Ka,3P Adjustable , Mccb - 630 Amps,36Ka,3P Adjustable , Bobin Insulators Clamps/Cliffs. , Epoxy Resin Cast Panel Insulators Upto 500Mm , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Al. Solderless Clamps Suitable For Transformer 1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 63 Kva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 50 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , Aluminium Thimbles 10 Mm2 As Per Relevant Is , Dpc Copper Winding Wire (Round) In Sizes 11 To 22 Swg Fresh. , Dcp Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 250 Kva To 630 Kva Fresh. , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg. , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg-Fresh , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva - Fresh , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg-Fresh , Dpc Copper Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Lv Brass Bush Rods 12 Mm , Lv Brass Bush Rods 19 Mm , Lv Brass Bush Rods 25 Mm , Lv Brass Bush Rods 32 Mm , Press Card Board Soft Calendared Solid 1Mm/2Mm/3Mm(As Per Sample) , Press Card Board Pre Compressed Solid 1Mm/2Mm/3Mm. , Ht Insulating Gum , Glass Wool Sleeves Of Sizes , Aluminium Brazing Rod (Standard Length) , Copper Brazing Rod (Standard Length) , Flexible Copper Strip (Shim) 75Mm X 0.5 Mm , Pvc Sheets 1 Mm Thick , Empire Tape 1 , Electrical Grade Kraft Paper, 4 Mil , Leatheroid Insulation Paper 20 Mil. , Hv Bushing , Lv Bushes Suitable For 63 To 100 Kva Dt , Lv Bushes Suitable For 200 To 250 Kva Dt , Lv Bushes Suitable For 400 To 630 Kva Dt , Epoxy Resin Cast 1.1 Kv Low Voltage Transformer Bushing With Busbar For 400/630 Kva Dt , Cotton Tape 1 (Size) 35 M Long. , Rubber Washers , Ht Paper , Cork Washer 12Mm Dia , Cork Washer20mm Dia , Cork Washer 25Mm/30Mm Dia , Plastic Metre Seals , Trifor (Tower Roller) , Transformer Oil Filitration Plant Filter Elements Of 1 Micron(60X250) Mm For Transformer Oil Filitration Plant , Heating Elements Of 2000 Watts For Transformer Oil Filtration Plant , Press Cardboard Cutter Having Bed=52X21 With Height Of Machine 45 With No. Of Tensile Springs 2 Nos. Complete In All Respects. , Angle Grinder, 800W Power, No-Load Speed Of 11000 Rpm, 100 Mm Disc , Welding Machine(Inverter Type) =5=10 Kva Rated Input Power, Maximum Welding Current At 60% Duty Cycle (In A) 150=250, Adjustable Hot Start,Anti-Stick Functions,Arc Force Control , Cordless Impact Drill/Drivers With 2 Batteries, Ideal For Driving Screws Into Wood And Drilling Into Masonry, Metal, And Wood , Pneumatic Air Impact Wrench With Sockets From 15 To 30 , Air Compressor 50 Ltr , Hand Held Brush Cutter , Hydraulic Crimping Tool , Pallet Truck 3 Ton , Hand Driven Insulation Resistance (Meggar) , Multimeter(Analog) , Multimeter(Digital) Voltage: Dc: 1000 Volts; Ac: 1000 Volts; Dc Accuracy: ± 0.5% + 3 Digit; Ac Accuracy: ± 1% + 3 Digit; Current: Dc: 10 Amps; Ac: 10 Amps; Dc Accuracy: ± 1.5% + 3 Digit; Ac Accuracy: ± 1.5% + 3 Digit; Resistance: 40 M Ohm; Resistance Accuracy: ± 1.5% + 3 Digit ; Capacitance: 1000 Μf; Capacitance Accuracy: ± 5% + 5 Digit Cat Iii 600 Volts Safety Rating , Pliers -Type Of Hand Tool-Combination Plier As Per Is 6149, Type Of Insulation-Rubber Insulation, Material-Carbon Steel , Nawara Tape 1 (Size) 35 M Long. , Rubberized Cork Sheet 4 Mm Thick 2Ftx3ft , Rubberized Cork Sheet 3Mm Thick 2Ftx3ft , Bakelite Tubes 12Mm Dia ( 1 Mtr Long) , Hv Bush Clamps (Ms) , Aluminium Clamping Member (Shoes) For Hv Bushing , Lv Cork Washers 12 Mm Dia , Lv Cork Washers 20Mm Dia , Lv Cork Washers 25 Mm/30 Mm Dia , Nuts & Bolts (M.S) Of Sizes. , M.S Flat Washers. , Hv Cork Washers 110 Mm O.D , Aluminium Welding Flux , Aluminium Flat 4/6/8/10 Mm Thick Of Required (Busbar) , Copper Flat 4/6/8/10 Mm Thick Of Required Width. (Busbar) , Ms Plug & Caps 1/2 ; 3/4; /1; 1.1/4; 1.1/2 , Oil Seal Rings (O-Rings) For Lv/Hv Bush Rods 12 Mm Dia. , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 20 Mm Dia , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 25 Mm Dia , Creep Tape 1 , Cotton Cloth , Empire Sleeves Of Sizes , Synthetic Enamel Paint Smoke Grey Colour , Paint Thinner , Steel Primer , Silica Gel , Transformer Oil As Per Is 335 And Amendments Thereof , Welding Rods 3.15 Mm/4Mm. (100 No. Per Packet) , Refilling Of Oxygen Gas For Brazing , Refilling Of Lpg Gas For Brazing , 12 Piece Tool Kit (1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench(Adjustib And 1-Piece Measuring Tape) Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 12 Volts, 42 Ah Lead Acid Battery , 12V 7 Ah Rechargeable Sealed Maintenance Free Battery (Smf) For Ups , Battery Connector For 12 V Battery Bank (12 No. Both Ends Of Each Connector Should Be Properly Clamped With Nuts, Bolts, Washers) , Fabricated Gi Pollar Collar 50X6 Mm With Nuts And Bolts , Digital Weighing Scale Upto 1 Ton , Portable Professional Petrol Chainsaw,18 Inch Or Above, 2 Kw Or Above, Pitch Of 3/8 Or Above, Petrol Capacity 400 Ml Or Above. , Double Ply Polyester Webbing Slings, Load Capacity 6 Tonne , Dee Shackles Forged Shackles, Working Load 6.5 Tonne , Eyebolt With Recessed Collar With Maximum Axial Lifting Capacity Of 6 Tonne , Handheld Brush Cutter / Line Trimmer, With Nylon Feed Head Attachment Petrol Engine Low Vibration Centrifugal Clutch, Hardened Steel 2 Teeth Blade, Bump / Tap & Go Type, Shaft Length (Mm) 1425 To 1449, Circular Saw Attachment Inclusive In The Scope Of Supply , Portable Hydraulic Crimping Tool For 30 Sqmm To 400 Sqmm With All Attachments , Pre Fabricate Galvanized Single Way Top Bracket (1000 Mm Long With 48.3 Od Gi Pipe) To Be Fitted On Top Of Octogonal Pole For Holding Lighting Luminaries. , Dk Thermoplastic Cable Junction/ Termination T Boxes 8X10Of Class Ip55/Ip65 Fitted With Two 2-5 annual periodical maintenance Mcb Strip,4-Way Terminal Block / Connectors Incl. Copper Lugs, Clamps ,Nut & Bolts Washers Etc (Hansel Or Equivalent Make) Or Poles With Two Way Type Bracket To Be Fitted Properly Inside The Door Opened Gear Box Provided On Thebottom Side Of The Pole. , Surge Protector For The 120/190 Watt Led Type Lighting Fixture Complete. , Outdoor Type Lt Control Panel Size 900Mmx900mmx450mm Having Input Main Control Of 100 annual periodical maintenance Mccb With Tpn Bus Bar With 40 annual periodical maintenance Tpn Mcb 4Nos For Outgoing Circuits,Including Astronomical Switching With Contactor Of Required Capacity. The Panel Should Be Fitted With A Digital Composite Voltmeter/Ampermeter/Indicator Set With Selecter Switch And Backup Protection System, Thimbling And The Panel Shall Further Be Provided With Proper Openings On Front Side As Well As On Rear Side Including Its Locking Arrangement And Also With Required Glands And 4No. Angle Iron Legs For Grouting The Panel On Bed , The Panel Shall Also Be Provided With Powder Coat/Pu Paint. The Item Includes Its Thimble As Required At Taping Point For Incomming , Out Going And Internal Panel Wiring Complete Unit. , Dust/Rain/Snow-Proof Canopy Type Mini-Outdoor Lt Feeder Panel Of Size 450X300mm With Front Door Opening Duly Powdered Colour Coated With Inbuilt 2No Tpn 16-32 annual periodical maintenance Mccb,Tpn Busbars Of Same Capacity Installed On Cement Concrete Block With 4 Angle Iron Legs Grouted In The Cement Concrete Of Termination Of Main 25Sqmm Cable And Outgoing 25/16 Sqmm Cable Circuits. , 120 Watt Led Luminaries Of Ip 67 Protection. , 190 Watt Led Luminaries Of Ip 67 Protection. , 110 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 70W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 50 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 30W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 6 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 10 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1Pole With 1Pp, 240 V , 10 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 240 V , 16 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 16 A Spn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2Pole With 1Pp, 415 V , 16 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3Pole With 3Pp, 415 V , 32 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , 32 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3 Pole With 3 Pp, 415 V , 32 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 415 V , 32 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1 Pole With 1 Pp, 415 V , 63 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , Astronomical Timer For Street Light Control, 3 Phase, 18 Kw/43 A Each Phase, Ip 66, Manually Settable Timer With 12 Programmes Spreaded Over A Year As Defined Programme, 260 Volt +/- 5 Volt Over Voltage Protection Per Phase, 160 Volt +/- 5 Volt Under Voltage Protection Per Phase, Operating Temperature Range -10 To +50 Deg C, /=60 Seconds On/Off Timing Accuracy , Embossing Punch Die Tool For Dt Coding (A-Z And 0-9) , Battery Operated Engraving Machine , Hand Operated Oil Pump/Barrel Pump , Manilla Rope - 25 Mm , Nylon Rope- 20 Mm , 11Kv Pilfer Resistant Metering Cubicle For 3Phase 4 Wire Metering System Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Panel Having Two Compartments Upper Meter Compartment And Lower Ct/Pt Compartment. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Sufrace, Dust, Weather And Vermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangments. The Metering Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening The Lv Chamber Door. , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 2.5 /5 For 25Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 5/5 For 63Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 7.5/5 For 100Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 15/5 For 200Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 20/5 For 250Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 25/5 For 400 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 50/5 For 630 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 75/5 For 1 Mva Dt , 11Kv/ 110 V, Three Phase Epoxy Resin Cast Pt With Rated Burden 15Va Per Phase And Accuracy Class 0.5 Or Better And Conforming To Is:3156 (Part-I&Ii) Amended Upto Date With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And Withstand Separate Source 23Kv providing fixing For One Minute. , 3Ph, 3 Wire Ht Ct/Pt Operated Fully Static Smart Tri-Vector Energymeters Dlms Compliantcategory C With Rs232 Port For Modem Compatibility. 11Kv/110V, Ph-Ph (3P,3W) Metersfor Measurement Of Different Electrical Parameters Including Active Energy (Kwh/ Mwh), Reactive Energy (Kvarh/Mvarh), Apparent Energy (Kvah/ Mvah) Etc. (Make L&T, Secure,Abb) , Led String Light 15 Mtr Long Of Different Colours (Saffron/White/Green) With Controller. , 4 Socket Extension Boards With Each Compatible Sockets Of 16 annual periodical maintenance And 5 Mtr Long Cable And Plug Along Surge Protector And On/Off Controller.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
41.
Power #11105146 Price Bid
Tender for Fixing Of Rate Contract For Supply Of Electrical Items/Key Materials/Spares/Minor Stores,T&P And Hardware Items For The Year 2026-27 , Fixing Of Rate Contract For Supply Of Electrical Items/Spares/Minor Stores,T&P And Hardware Items For The Year 2026-27 , Almunium Thimbles 70Mmsq. , Almunium Thimbles 95Mmsq. , Almunium Thimbles 120Msq. , Almunium Thimbles 185Mmsq. , Almunium Thimbles 240Mmsq. , Almunium Thimbles 300Mmsq. , Almunium Thimbles 400Mmsq. , Almunium Thimbles 630Mmsq. , Almunium Bus Bar Of Sizes , Acsr Weasel Conductor 30Mmsq , Acsr Rabbit Conductor 50Mmsq , Acsr Squirrel Conductor 20Mmsq , Angle Iron 40X40x6mm Ms , Angle Iron 40X40x6mm Gi , Channel Iron 75X40x6mm Ms , Channel Iron 75X40x6mm Gi , Red Oxide Paint , Almunium Paint , Chain Link Mesh Fencing 6Ft Height 2 X 2 , Changeover Switch 63A 3-Phase 4 Pole Side Handle Type , Changeover Switch 100A 3-Phase 4 Pole Side Handle Type , Changeover Switch 200A 3-Phase 4 Pole Side Handle Type , Changeover Switch 300A 3-Phase 4 Pole Side Handle Type , Changeover Switch 400A 3-Phase 4 Pole Side Handle Type , Changeover Switch 630A 3-Phase 4 Pole Side Handle Type , 25Kva Distribution Transformer Eel-2,11/0.433 Kv, 3-Phase , 63Kva Distribution Transformer Eel-3,11/0.433 Kv, 3-Phase, , 100Kva Distribution Transformer Eel-4,11/0.433 Kv, 3-Phase, , 11Kv Disc Fittings Type (T&C) For Squirrel/ Weasel/Rabbit/Dog Conductor , 11Kv Disc Fittings Type (B&S) For Squirrel/ Weasel/Rabbit/Dog Conductor , 11Kv Disc Insulators Porcelain (T&C) Type 45Kn , 11Kv Disc Insulators Porcelain (T&C) Type 45Kn , 11Kv Disc Insulators Polymer (T&C, B&S Type) 45Kn , 11Kv Pin Insulator Polymer Type 5Kn , 11Kv Pin Insulator Porcelain Type 5Kn , 11Kv Pin Insulator (Porcelain) Type 5Kn , 11Kv G. I Pin 800 Gms , Guy Insuators 11Kv , Guy Insulators Lt , Lt Shackle Insulators , 11Kv D O Set (75X45x6)Mm , 11Kv Link Set (50X6) Heavy Duty , 11Kv Horn Gap Set (50X6) Heavy Duty , 11Kv G O Set With Pipes Complete Set Heavy Duty , 11Kv Guy Rods Complete Set With Straining Screw, Anchor Plate And Turn Buckles Complete , Lt Guy Rods Complete Set With Straining Screw, Anchor Plate And Turn Buckles Complete , Guy Wire 7/14Swg , G I Wire 8 Swg , Lt Spacers Of Sizes (1-Phase To 3 Phase Line) , 63 A Iron Clad Switches 3 Phase , 100 A Iron Clad Switches 3 Phase , 200 A Iron Clad Switches 3 Phase , 300 A Iron Clad Switches 3 Phase , 400 A Iron Clad Switches 3 Phase , 630 A Iron Clad Switches 3 Phase , Pvc Tape , Manila Rope 1 Thick , Lifting & Pulling Machine 5-8 Tonne Isi Make , Lifting & Pulling Machine 3-5 Tonne Isi Make , Lifting & Pulling Machine 1-3 Tonne Isi Make , Mccb 63A 3 Pole 35Ka , Mccb 63A 4 Pole 35Ka , Mccb 100A 3 Pole 35Ka , Mccb 100A 4 Pole 35Ka , Mccb 200A 3 Pole 35Ka , Mccb 200A 4 Pole 35Ka , Mccb 250A 3 Pole 35Ka , Mccb 250A 4 Pole 35Ka , Mccb 400A 3 Pole 35Ka , Mccb 400A 4 Pole 35Ka , Mccb 630A 3 Pole 35Ka , Mccb 630A 4 Pole 35Ka , M S Nuts & Bolts Of Sorts Half Thread , M S Nuts & Bolts Of Sorts Full Thread , Galvanised Nuts & Bolts Of Sorts Half Thread , Galvanised Nuts & Bolts Of Sorts Full Thread , 11Kv Disc Insulators With Fittings , G I Earthing Plate 2X2x6 , G I Pipe 1.5 Dia 10Ft Long , Earthing Wire Copper 4Swg , 11Kv Safety Rubber Hand Gloves Isi Make , 11Kv Ct/Pt Unit Complete Dry Type Of Various Ratios , 11Kv Ct/Pt Unit Complete Oil Type Of Various Ratios , 35Mmsq. Xlpe Cable 3.5Core Armoured Lt , 50Mmsq. Xlpe Cable 3.5Core Armoured Lt , 70Mmsq. Xlpe Cable 3.5Core Armoured Lt , 95Mmsq. Xlpe Cable 3.5Core Armoured Lt , 120Mmsq. Xlpe Cable 3.5Core Armoured Lt , 185Mmsq. Xlpe Cable 3.5Core Armoured Lt , 35Mmsq. Xlpe Cable 3.5Core Unarmoured Lt , 50Mmsq. Xlpe Cable 3.5Core Unarmoured Lt , 70Mmsq. Xlpe Cable 3.5Core Unarmoured Lt , 95Mmsq. Xlpe Cable 3.5Core Unarmoured Lt , 120Mmsq. Xlpe Cable 3.5Core Unarmoured Lt , 185Mmsq. Xlpe Cable 3.5Core Unarmoured Lt , 35Mmsq. Xlpe Cable Single Core Unarmoured Lt , 50Mmsq. Xlpe Cable Single Core Unarmoured Lt , 95Mmsq. Xlpe Cable Single Core Unarmoured Lt , 120Mmsq. Xlpe Cable Single Core Unarmoured Lt , 185Mmsq. Xlpe Cable Single Core Unarmoured Lt , 240Mmsq. Xlpe Cable Single Core Unarmoured Lt , 300Mmsq. Xlpe Cable Single Core Unarmoured Lt , 400Mmsq. Xlpe Cable Single Core Unarmoured Lt , 630Mmsq. Xlpe Cable Single Core Unarmoured Lt , 35Mmsq 11Kv Cable 3 Core Xlpe (Armoured) , 50Mmsq 11Kv Cable 3 Core Xlpe (Armoured) , 70Mmsq 11Kv Cable 3 Core Xlpe (Armoured) , 95Mmsq 11Kv Cable 3 Core Xlpe (Armoured) , 120Mmsq 11Kv Cable 3 Core Xlpe (Armoured) , 185Mmsq 11Kv Cable 3 Core Xlpe (Armoured) , 300Mmsq 11Kv Cable 3 Core Xlpe (Armoured) , 35Mmsq 11Kv Cable 3 Core Xlpe (Un-Armoured) , 50Mmsq 11Kv Cable 3 Core Xlpe (Un-Armoured) , 70Mmsq 11Kv Cable 3 Core Xlpe (Un-Armoured) , 95Mmsq 11Kv Cable 3 Core Xlpe (Un-Armoured) , 120Mmsq 11Kv Cable 3 Core Xlpe (Un-Armoured) , 185Mmsq 11Kv Cable 3 Core Xlpe (Un-Armoured) , 300Mmsq 11Kv Cable 3 Core Xlpe (Un-Armoured) , 35Mmsq 11Kv Xlpe Aeriel Bunched Cable , 50Mmsq 11Kv Xlpe Aeriel Bunched Cable , 70Mmsq 11Kv Xlpe Aeriel Bunched Cable , 95Mmsq 11Kv Xlpe Aeriel Bunched Cable , 120Mmsq 11Kv Xlpe Aeriel Bunched Cable , 185Mmsq 11Kv Xlpe Aeriel Bunched Cable , 300Mmsq 11Kv Xlpe Aeriel Bunched Cable , 3X35+1X25+1X16 Lt Aeriel Bunched Cable , 3X50+1X35+1X16 Lt Aeriel Bunched Cable , 3X70+1X35+1X16 Lt Aeriel Bunched Cable , 3X95+1X35+1X16 Lt Aeriel Bunched Cable , 3X120+1X50+1X16 Lt Aeriel Bunched Cable , 11Kv Lightening Arrestor Polymer Station Type , 11Kv Lightening Arrestor Porcelain Station Type , 11Kv Lightening Arrestor Porcelain Line Type , Suspension And Tension Clamps For Ab Cable , Chain Block 1Mt Of Standard Quality And Make , Chain Block 2Mt Of Standard Quality And Make , Chain Block 3Mt Of Standard Quality And Make , Chain Block 5Mt Of Standard Quality And Make , 11Kv Operating Rod Bamboo (Heavy Duty) , Pvc Wire Multi Strand 1 Mmsq. , Pvc Wire Multi Strand 1.5Mmsq. , Pvc Wire Multi Strand 2 Mmsq. , Pvc Wire Multi Strand 2.5 Mmsq. , Pvc Wire Multi Strand 3 Mmsq. , Pvc Wire Multi Strand 4 Mmsq. , Pvc Wire Multi Strand 6 Mmsq. , Bamboo Ladder 12Ft Long , Bamboo Ladder 20Ft Long , Bamboo Ladder 30Ft Long , Almunium Telescopic Ladder 20Ft Long , Almunium Ladder Extendable 30Ft Long , Almunium Ladder 10Ft To 20Ft Long , Mucky Clamps Complete Set (50 X 6) Gi , U Clamps 50X6 , Back Clamps 50X6 (Galvanised) , P P Rope Of Sizes , Prodigy Meter (Secure/L&T/Hpl,Etc.) , 3 Phase 4 Wire Trivector Meter With Box (Secure/Hp/L&T,Etc) , 1 Phase 5-30/10-60 A Electronic Energy Meter With Box (Secure,Hpl,L&T,Etc) , Meter Seal , Lipi Line Cartridge (6800/6805/6600) , Cartridge For Dot Matrix Printer , Cartridge For Printer Hp Laser Jet 136N (110A) , Cartridge For Printer Canon Imageclass Mf3010 , Toner/Cartridge For Photocopier Machine Canon Imagerunner 2006N , Almunium Twin Core Cable 4 Mmsq. , Almunium Twin Core Cable 8 Mmsq. , Almunium Twin Core Cable 10 Mmsq. , Almunium Twin Core Cable 16 Mmsq. , Copper Wire Of Size 1.5Mm , Copper Wire Of Size 2.5Mm , Copper Wire Of Size 4.0Mm , Copper Wire Of Size 6.0Mm , Pvc Control Cable Copper 10 Core 2.5Mmsq. , Pvc Control Cable Copper 12 Core 2.5Mmsq. , Led 9W Lamp , Led Flood Light 100W (Havels O Some Reputed Company Make) , Meter Box Compatable For Housing Trivector Meter , Plier 6 Inch Heavy Duty , Plier 9 Inch Heavy Duty , Meggar Digital 5000V Make Meco Insulation Tester , High Voltage Detector , Earthing Discharge Rod , Clamp Tester , Earth Tester , Search Light Heavy Duty Chargeable , Torch Chargeable , Prodigy Meter , Drilling Machine With 3-Phase Motor And Stand (Heavy Duty) , Drill Bit 10Mm/16Mm Size (Heavy Duty) , Dril Bit 20Mm Size (Heavy Duty) , Insulation Piercing Contact Of Sizes (50Msq/120Mmsq) , 11Kv Ct/Pt Unit Of Various Ratios Including 3-Phase 4 Wire Trivector Meter Wih Compatable Meter Box And Pvc Control Copper Cable 10 Core Having 10Mtr. Length , 35Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 50Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 95Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 120Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 185Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 300Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 400Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 630Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv For Xlpe/Ab Cables , 35Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 50Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 95Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 120Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 185Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 300Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 400Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 630Mmsq Heat Shrinkable Kit (Outdoor Type) 11Kv Straight Through Type , 35Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 50Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 95Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 120Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 185Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 300Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 400Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 630Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv Lt For Xlpe/Ab Cables , 35Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 50Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 95Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 120Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 185Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 240Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 300Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 400Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , 630Mmsq Heat Shrinkable Kit (Outdoor Type) 1.1Kv For Lt Ab/Xlpe Cables (Straight Through Type) , Bush Rods M12 Ht , Ht Bush Porcelain , Bush Rod M12 Lt , Bush Rod M20 Lt , Bush Rod M30 Lt , Lv Bushings For M12 Rod , Lv Bushings For M20 Rod , Lv Bushings For M25 Rod , Lv Bushings For M30 Rod , Transformer Oil (Fresh) , Oil Seal Lt , Oil Seal Ht , Bimetallic Connectors Suitable For Lt Bush Rod Of 12Mm , Bimetallic Connectors Suitable For Lt Bush Rod Of 20Mm , Bimetallic Connectors Suitable For Lt Bush Rod Of 30Mm , Guy Sets Complete Including Wire And Insulator , Bobbin Insulators Or Supporting Earthing Strip , Almunium Paint , Cotton Waste (Old Clothes/Sarees) , Charcoal Stone , Salt For Earthing Of Dts (Crystal) , Chemical For Earthing , G I Strip For Earthing , Lt Distribution Box With Clamp For Fixing On St Pole Of Different Capacities , Fuse Wire Of Different Sizes , Search Light 50W Heavy Duty Chargeable , Iron Cutter Machine (Standard Company Make) , Safety Jackets , Safety Helmets Isi Marked , Safety Belt Isi Marked , Safety Shoes (Duck Back Or Some Reputed Compnay Make) Of Nos 7/8/9 , Steel Tubular Pole 8Mtr Long (410 Sp 15) , Steel Tubular Pole 9Mtr Long (410 Sp 33) , Copper Plate For Earthing (2Ft X2 Ft) 3Mm , Rain Coat (Duck Back Or Some Reputed Company Make) , Welding Machine Portable (Reputed Company Make) , Welding Electrodes , Ring Spanner Set , Rain Coat (Duck Back Or Some Reputed Company Make) , Pipe Wrench , Rolling Pulley , Come Along Clamp For Weasel/Rabbit/ Dog Conductor , Hook On Meter /Tong Tester , Electronic Weighing Machine (Upto 500Kgs) , Digital Multimeter Ac/Dc Both , P G Clamps 630A , Bus Bar Insulators , Cutter Blades For Iron Cutting Machine , Hdpe Helmet With High Voltage Detector , Hdpe Helmet With Torch/Lamp , Baby Insulator Complete With Back Clamp Angle For Gi Strip Support
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
42.
Railways #11102145 AOC
Supply Of supply of spares of automatic fire detection cum suppression system , control panel part no.- jk-fdss-1225 make -jk exim or similar. [ warranty period: 30 months after the date of delivery ] ] , control panel relay card part no.- jk-fdss-1226 make -jk exim or similar. [ warranty period: 30 months after the date of delivery ] ] , control panel data logger card part no.- jk-fdss-1227 make - jk exim or similar [ warranty period: 30 months after the date of delivery ] ] , dc/dc convertor (110 v to 24 v dc) part no.- jk-fdss-1229 make -jk exim or similar [ warran ty period: 30 months after the date of delivery ] ] , smoke detector part no.- jk-fdss-1230 make -jk exim or similar [ warranty period: 30 mont hs after the date of delivery ] ] , heat detector part no.- jk-fdss-1231 make -jk exim or similar [ warranty period: 30 months after the date of delivery ] ] , solenoid valve part no.- jk-fdss-1210 make -jk exim or similar. [ warranty period: 30 month s after the date of delivery ] ] , ms hax bush part no.- jk-fdss-1211 make- jk exim or similar [ warranty period: 30 months after the date of delivery ] ] , end wago connector part no.- jk-fdss-1238 make -jk exim or similar. [ warranty period: 30 months after the date of delivery ] ] , cable gland part no.- jk-fdss-1239 jk exim or similar. [ warranty period: 30 months after th e date of delivery ] ] , control panel cpu card part no.- jk-fdss-1240 make -jk exim or similar. [ warranty period: 30 months after the date of delivery ] ] , pressure gauge bush part no.- jk-fdss-1241 make -jk exim or similar. [ warranty period: 30 months after the date of delivery ] ] , flasher hooter/ sounder beaker part no.- jk-fdss-1234 make -jk exim or similar. [ warranty period: 30 months after the date of delivery ] ]
Contract Date: May 18, 2026 Contract Value : 6.64 Lakh
Government Departments No of Bidders 1
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 6.67 Lakh
Government Departments No of Bidders 6
Andhra Pradesh View Result →
46.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
47.
Railways #11054333 AOC
Supply Of up-rh-dn-lh , nut m8 b0200800 ] , 280-314- intermediate plate for 2.5 mm 2 in 2 out ] , teknic plastic 22.5 mm dia flush actuator yellow-p2af8 ] , gland plate 51-model no lmc51 ] , ss philip csk head screw m4 x 25 head dia 7 x height 2 mm ] , cable pvc gland pg 21 ] , 1.5 sq. mm yellow with green wire 1.7m ] , tighting wire with zinc white plating-f01.a40cj.518a01 ] , wire cable copper pvc ins. 0.75 sq. mm black 0.7m ] , qcfc - m 20/16 gland ] , 16 amps 2 pin socket ] , 249-116 end clamp for wago terminal ] , 280-402 horizontal jumper insulated ] , moving contact holder 36-00-12-01 ] , v3-fault collection board ] , radec sensor model m ] , multi sensor (smoke & heat detector) - 4 wire system - aw - csh831 -4w ] , qdqt0419-buzzer-black ] , 280-833-2 in 2 out 2.5 sq. mm terminal block (grey) ] , panasonic led bulk head 10w, 6500k white - pbhm01107 ] , head push button stay put red colour raas control make type no rcb2-bs54 ] , selector actuator (plastic) 2 position (maintained contact) with 1 no c element-teknic 22.5 m m dia ] , standard cables for rdso yasakawa drive ] , step sag & jumping - up -rh-dn-lh handrail entry s/w schmersal t1r236-02z-m20 ] , up-lh - dn - rh comb - rh drive chain s/w schmersal - z1r236-o2zr-u180-1816 ] , pan philip head screw m 5 x 25 ] , plain washer 6 b)300700 ] , up-rh-dn-lh comb - rh-step chain - s/w schmersal - z1r236-02zr-1816 ] , jeh ip 55 bmb controller box 420 x 330 x 150 ] , plain washer m 8 9 id x 17 od x 1.6 mm ] , inspection plug assy. all ipa-123 ] , entry sensor bracket- jeh escalator ]
Contract Date: May 11, 2026 Contract Value : 4.93 Lakh
Government Departments No of Bidders 1
West Bengal View Result →
48.
Railways #11050474 AOC
Bids Are Invited For Luminous Jackets - Heavy Duty Luminous Safety Jacket With Printed Or Stitched Logo Security Dfccil On The Front And Back. The Jacket Shall Be Made Of High Visibility Fluorescent Polyester Fabric Of Minimum 120 To 150 Gsm, Durable And Suitable For Outdoor Duty. The Colour Of The Jacket Shall Be Fluorescent Orange For Maximum Visibility. It Shall Be Provided With High Quality 3M Retro Reflective Bands Of Minimum 50 Mm Width And Min. 3.0M Length On Both The Front And Back. The Jacket Shall Be Of Assorted Sizes With Comfortable Fitting And Proper Stitching, As Per Buyer Requirement. The Jacket Should Be Breathable, And Suitable For Prolonged Use During Day And Night Duty. , Belt Web Belt Black Colour With Belt Badge - Made Of High-Density Woven Polyester Or Cotton Webbing, 38 To 45 Mm Wide, Black In Colour, With Tight Weave For Durability. The Belt Ends Shall Be Heat Sealed Or Reinforced With Stitching And Shall Have Minimum Tensile Strength Of Approximately 800 To 1000 N. The Buckle Shall Be Made Of Brass Or Nickel Plated Brass With Chrome Or Nickel Polished Finish, Of Clamp Or Detachable Type Suitable For The Web Belt. The Buckle Shall Bear The Dfccil Logo With The Word Dfccil As Approved By The Buyer, Along With An Embossed Or Engraved Official Security Crest Or Emblem. The Buckle Shall Be Rust Resistant With Uniform Colour And Finish, Free From Cracks Or Scratches, And Firmly Fixed And Properly Aligned. , Lanyard Black Colour - Made Of Braided Cotton, Nylon, Or Polyester Cord With Strong Woven Or Braided Construction. The Lanyard Shall Be Black In Colour With Smooth, Uniform, And Colour Fast Finish. It Shall Be Designed As A Single Shoulder Lanyard Suitable For Wearing On Uniform, With Overall Length Approximately 70 To 90 Cm And Cord Diameter About 4 To 6 Mm. The Lanyard Shall Consist Of A Shoulder Loop With A Hanging Cord For Attachment Of Whistle Or Keys. It Shall Be Fitted With A Spring Hook Or Swivel Clip Made Of Brass, Stainless Steel, Or Nickel Plated Metal With Corrosion Resistant Polished Finish. The Braiding Shall Be Uniform With No Loose Threads, And Knotting Braiding Shall Be Strong To Prevent Fraying. The Metal Fittings Shall Be Securely Attached And Suitable For Extended Duty Wear. The Lanyard Shall Be Manufactured As Per The Design Shown In The Attached Photograph. , Whistle Silver Colour - Made Of Stainless Steel Or Nickel Plated Brass With Silver Coloured Polished Finish. The Whistle Shall Be Rust-Resistant And Suitable For Outdoor Use. It Shall Be Of Standard Poice Pattern, Either Pea Whistle With Internal Shound Ball Or Pea Less Police Whistle Type. The Surface Shall Be Smooth And Well Polished Without Any Sharp Edges. The Whistle Shall Be Durable, Corrosion Resistant And Suitable For Use With Uniform Lanyard. The Whistle Shal Be Manufactured As Per Design Shoen In The Attached Photograph , Insignia As Per Dfccil Design - Made Of Brass, Stainless Steel, Or Die Cast Metal With Nickel Or Chrome Plated Metallic Silver Finish. Shape, Lettering, And Symbol As Per Approved Dfccil Emblem Design As Per Approved Dfccil Pattern. Back Fitting Type Butterfly Clutch Pin, Screw Post, Or Safety Pin Suitable For Uniform Wear. Surface Smooth And Polished, Free From Sharp Edges Or Plating Defects, With Corrosion Resistant Finish. , Dfccil Badge Silver Colour - Exact Design Of The Official Dfccil Emblem Or Logo As Per Approved Pattern Shown In The Attached Photograph. Base Material Brass Or Die-Cast Metal With Polished Silver Finish Using Nickel Or Chrome Plating Or Equivalent Corrosion-Resistant Coating. Surface Smooth And Glossy, Free From Discoloration Or Plating Defects. Size As Per Approved Dfccil Sample Design. Back Fitting Butterfly Clutch Pin, Screw Post With Backing Nut, Or Safety Pin Suitable For Uniform Fabric. Edges Smooth Without Burrs Or Sharp Points, With Clear And Crisp Detailing Of The Emblem And Durable Corrosion Resistant Plating. , Beret Cap For Guards Khaki Colour With Dfccil Batch - Khaki Coloured Beret Cap Suitable For Uniformed Guard Duty Wear, Made Of Wool Blend, Polyester Wool Mix, Or High Quality Serge Fabric. Inner Lining Smooth For Comfort With Leather Or Cotton Sweatband For Moisture Absorption. Standard Military Style Beret With Rounded Top And Reinforced Stitched Edge Binding. Size Adjustable With Interal Band Or Drawstring. Dfccil Emblem Badge Fixed At The Front Centre. Badge Made Of Nickel-Plated Brass Or Die-Cast Metal With Silver Finish And Secure Pin Or Screw Back Fitting. Fabric Free From Defects Such As Tears, Stains, Or Uneven Colour, With Smooth Internal Lining And No Loose Threads. Cap Maintains Proper Shape During Use And Suitable For Prolonged Outdoor Duty. Batch Marked With Size, Manufacturer, And Dfccil Reference. , Shoulder Batch Dfccil - Embroidered Shoulder Badge Bearing The Official Dfccil Emblem For Attachment On Uniform Shirts Or Jackets. Fabric Backing Khaki Or Black Matching The Uniform, Embroidered With Polyester Or Metallic Silver Colour Thread. Backing Provided With Stiffener Board To Maintain Shape. High Quality Embroidery With Uniform Stitching And No Loose Threads. Design, Shape, And Dimensions As Per Approved Dfccil Pattern Shown In The Attached Photograph. Suitable For Stitching On Uniform Shoulder Or Epaulet With Durable Construction And Proper Attachment Strength. , Led Torches Black Colour - Heavy Duty Rechargeable Hand Torch Dragon Type With Minimum 3W Led Light Source, Suitable For Security And Night Duty Use. Body Made Of Durable Aluminium Alloy Or High Impact Abs With Black Finish, Providing Strong Grip And Rugged Construction. Rechargeable Battery With Suitable Charger, Providing Long Illumination Range And Reliable Performance. Compact Hand Held Design With On Or Off Switch And High Intensity Focused Beam. Make Of Fos, Wipro, Crompton Or Equivalent As Approved By The Buyer. , Raincoat Khaki Colour - Khaki Coloured Waterproof Raincoat With Hood Suitable For Security Personnel On Outdoor Duty. Made Of Pvc Coated Polyester Or Nylon Waterproof Fabric Of Approximately 180 To 250 Gsm With Smooth, Durable, And Flexible Finish. All Seams Heat Sealed Or Double Stitched And Taped To Ensure Complete Waterproofing, Using High Strength Polyester Stitching Thread. Colour Khaki Matching Rpf Dfccil Uniform Shade. Provided With Functional Buttons Or Zipper Closure And Reflective Strips On Front And Back For Visibility During Night Duty. Raincoat Free From Cuts, Holes, Wrinkles, Or Coating Defects, With Waterproof Coating Resistant To Peeling Or Cracking. Sizes Supplied As Per Consignee Requirement And Each Raincoat Packed Individually In A Polybag Or Waterproof Pouch. , Binoculars - Portable High Power Binocular With Approximately 20X Magnification And Wide Angle Lens, Suitable For Surveillance And Field Use. Compact And Lightweight Design With Central Easy Focus Mechanism And Durable Body. Waterproof Or Water Resistant Construction With Clear Optics For Long Distance Viewing. Supplied As A Complete Package Including Carrying Case, Neck Strap, Lens Caps, And Cleaning Cloth. Make Of Celestron, Nikon, Vortex, Carson Cason Or Equivalent As Approved By The Buyer. , Hhmd Handheld Metal Detector - Heavy Duty Handheld Metal Detector Suitable For Security Screening Applications. High Sensitivity Detection With Audio Or Vibration Alarm For Detection Of Ferrous And Non Ferrous Metals. Ergonomic Handheld Design With Durable Body, Easy Operation, And Quick Response. Operated By Lithium Primary Battery With Low Power Consumption And Long Operating Life. Lightweight, Compact, And Suitable For Continuous Duty Use. Supplied With Necessary Accessories And User Manual. Make Of Garrett, Fisher, Quest Metal Detector, Minelab Or Equivalent As Approved By The Buyer. , Polycarbonate Lathi - Heavy Duty Polycarbonate Lathi Suitable For Security Duty, Made Of High Impact Polycarbonate Material. Length 100 Cm, Outer Diameter 25 Mm, Wall Thickness 4.0 Mm, And Weight Approximately 350 G. Smooth Surface With Comfortable Grip And Durable Construction Suitable For Regular Field Use. Make Or Brand Of Garud, Protek, Bajaj, Nirbhay Or Equivalent As Approved By The Buyer. , Loud Hailer With Siren - Heavy Duty Portable Loud Hailer With Minimum 20 W Output Power, Suitable For Public Announcement And Security Applications. Unidirectional Design With Adjustable Volume Control And Built In Siren Function. Provided With Detachable Handheld Microphone With Press To Talk Switch. Durable Body With Ergonomic Grip And Shoulder Strap For Easy Carrying. Battery Operated With Clear And High Intensity Sound Projection For Long Distance Communication. Make Of Soundtech, Protech, Ravon, Moglix Or Nexa Or Equivalent As Approved By The Buyer. , Patrolling Vehicle Beacons - Heavy-Duty Flashing Beacon Light Suitable For Patrolling Or Security Vehicles, With Durable Lighting Box And Magnet Shoe Mounting Base Plate For Easy Installation On Vehicle Roof. Highv Isibility Rotating Or Flashing Led Light With Weather Resistant Housing And Clear Lens For Effective Signaling During Patrol And Emergency Situations. Robust Construction Suitable For Outdoor Use With Reliable Illumination. Make Garud, Skylark, Hella, Nirbhay Or Equivalent As Approved By The Buyer. Total Quantity : 709
Contract Date: Ref. Documents Contract Value : 3.02 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Madhya Pradesh View Result →
50.
Educational and Research Institute #11047682 AOC
Supply Of It And Lab Equipment= 2 Computer Notebook Processor Make Intel/Amdprocessor Generation Min Intel 14Th Gen Core I5 / Amd Ryzen 5 8000 G Seriesnumber Of Cores Per Processor Min 4 Coreschipset Series Any Valuegraphics Type Integratedoperating System (Factory Pre-Loaded) Windows 11 Professional Type Of Ram Ddr5Ram Size (Gb) 8 Gb Minimumram Speed (Mhz) Min. 3200 Or Higherram Expandability Up To (Using Spare Dimm Slots In Gb) Min. 32 Gbcapacity Of Ssd (Gb) Min 512 Gb Ssdwireless Connectivity Integrated Gigabit Ethernetwi-Fi 6 Or Higher With Bluetooth Enabled 5.0 Or Higherled Backlight Monitor Size (Inches) Min 14 Inch With Integrated Cameradisplay Resolution (Pixels) Min. 1920 X 1080Panel Technology Ips/Tn/Wva Speaker, Wireless Connectivity, Ethernet Port 1 Qty, Bluetooth, Usb Port 2 Qty, Hdmi Port 1 Qty, Battery Warranty 5 Year, Web Camera Yeson-Site Oem Warranty 5 Year Onsite Oem Warrantyoem For Desktop Should Be Among The Listed Products In Gartner Magic Quadrant Or In Idc India Report During The Last 5 Years (In All Quarters) 3 Desktop Computer Processor Make Intel/Amdprocessor Generation Min Intel 14Th Gen Core I7 / Amd Ryzen 7 8000 G Seriesnumber Of Cores Per Processor Min 8 Coreschipset Series Compatible To The Required Configurationslots And Ports Minimum Requirement , Bidders Can Offer More As Per Their Product Designone Ethernet Rj-45One Display Portone Hdmione Audio Line Out3 Nos Usb 2.0 Ports4 Nos Usb 3.2 Ports (Including Type C)1 Pci Express X161 Pci Express X 11 M.2 Slots For Storagegraphics Type Integratedoperating System (Factory Pre-Loaded) Windows 11 Professional (Oem Declaration Regarding Genuine Activated Preloaded Windows 11 Professional) Type Of Ram Ddr5Ram Size (Gb) 16 Gb Minimumram Speed (Mhz) Min. 4800 Or Higherram Expandability Up To (Using Spare Dimm Slots In Gb) Min. 64 Gbcapacity Of Ssd (Gb) Min 512 Gb Ssdwireless Connectivity Integrated Gigabit Ethernetwi-Fi 6 Or Higher With Bluetooth Enabled 5.0 Or Highermonitor Size (Inches) Min. 23.8 Inch Or Higher And Should Be Same Oem For Which Desktop Is Offered, With Tco Certifieddisplay Resolution (Pixels) Min. 1920 X 1080Panel Technology Ips/Ledmouse Connectivity Wired Keyboard Connectivity Wired On-Site Oem Warranty 3 Year Onsite Oem Warrantycertification Bis, Ul, Rohs, Bee/Energy Star, Epr, Iso: 9001,Additional Requirement Bidder To Supply Factory Pre-Loaded Windows 11 Professional And Ms Office Academic Edition 2021 Along With Antivirus License Valid For 5 Years From Date Of Activation.Note: Licenses Of Software Shall Be Valid Till 5 Years Warranty. Bidder To Submit Confirmation From Microsoft To Supply Genuine License Software For All The Systems.Oem For Desktop Should Be Among The Listed Products In Gartner Magic Quadrant Or In Idc India Report During The Last 5 Years (In All Quarters)Audio With Built In Speaker In Monitor/Desktop 4 Computer Notebook Processor Make Intel/Amdprocessor Generation Min Intel 14Th Gen Core I7 / Amd Ryzen 7 8000 G Seriesnumber Of Cores Per Processor Min 8 Coreschipset Series Any Valuegraphics Type Integratedoperating System (Factory Pre-Loaded) Windows 11 Professional Type Of Ram Ddr5Ram Size (Gb) 16 Gb Minimumram Speed (Mhz) Min. 4800 Or Higherram Expandability Up To (Using Spare Dimm Slots In Gb) Min. 64 Gbcapacity Of Ssd (Gb) Min 512 Gb Ssdwireless Connectivity Integrated Gigabit Ethernetwi-Fi 6 Or Higher With Bluetooth Enabled 5.0 Or Higherled Backlight Monitor Size (Inches) Min 14 Inch With Integrated Cameradisplay Resolution (Pixels) Min. 1920 X 1080Panel Technology Ips/Tn/Wva Speaker, Wireless Connectivity, Ethernet Port 1 Qty, Bluetooth, Usb Port 2 Qty, Hdmi Port 1 Qty, Battery Warranty 5 Year, Web Camera Yeson-Site Oem Warranty 5 Year Onsite Oem Warrantyoem For Desktop Should Be Among The Listed Products In Gartner Magic Quadrant Or In Idc India Report During The Last 5 Years (In All Quarters) 5 Audio Visual Equipment Audio Visual Equipment In A Language Lab Enriching, Language Learning By Providing Engaging, Interactive, And Multi Sensory Experience 6 Recording Devices Recording Devices In A Language Lab Provide Valuable Opportunities For Listening, Speaking, Assessment, And Self Directed Learning They Enhance Language Acquisition By Offering Practice, Feedback, And Exposure To Authentic Language Content 7 Lcd Projector Type Of Display Poly Silicon Tft Active Matrixresolution 1024 × 768 Pixels (Xga) / 1280 × 800 Pixels (Wxga)Lens F= 1.80,Focal Length: 3.71 Mmcolor Reproduction Full Color, 16.77 Million Colorsbrightness Normal Power Consumption Mode:White Light Output 3100 Lumens (Iso 21118 Standard)Color Light Output 3100 Lumenseco Power Consumption Mode:White Light Output 1800 Lumens (Iso 21118 Standard)Contrast Ratio 3000 To 1 With Auto Iris On And Normal Power Consumption Modeimage Size 55.9 To 93.2 Inches (1.42 To 2.37 M)/ 60 To 100 Inches (1.52 To 2.54 M)Projection Distance 13.7 To 23.5 Inches (0.35 To 0.60 M)Projection Methods Front, Wall Or Ceiling-Mountedoptical Aspect Ratio(Width-To-Height) 4:3 Or Better Focus Adjustment Manualzoom Adjustment Digitalzoom Ratio(Tele-To-Wide) 1:1.35Internal Sound System 16 W Monauralnoise Level 35 Db (Normal Power Consumption Mode)28 Db (Eco Power Consumption Mode)Keystone Correction Angle Vertical: ± 5ºhorizontal: ± 5ºusb-B Port Compatibility Usb 1.1 And 2.0 Compliant For Usb Display Or External Mouseusb-A Port Compatibility One Usb 1.1 And 2.0 Compliant Port For Usb Device Input Or Epson Document Camera Display 8 Acoustic Panel1 Unit Type Piece2 Product Unit 100 Piece3 Color Black And White4 Product Type 3D Acoustic Wall Panel5 Application Floors & Roofs, Walls, Columns & Beams 9 Headphone, Microphone And Speaker Item Dimensions L Into W Into H7 Point 6 Into 4 Into 25 Point 8 Centimetresconnectivity Technology Wired 3 Point 5 Mmcolorblack 10 Upstechnical Specification Item Description Of Minimum Requirementrating In Kva (Kva) 2.0 Kvatechnology Igbt-Pwm With Or Without Inbuilt Isolation Transformerinput Power Single Phase 160V - 260V Signwave 50Hzinput Frequency Range 50 Hz +/- 6% Hzoutput Power Single Phase 230V +/-1%Output Frequency Range 50 Hz +/- 6% Hzout Wave Form Pure Signwavebackup Time (Minutes) Min. 60 Minutes On Full Loadminimum Vah (Vah) Min. Vah 3200Noise Level (1 Meter Distance Fro Ups) /=90%50% Overload Limit For Minimum 1 Minutes Yestotal Harmonic Distortion (Thd) (%) Maximum 3% 11 Multifunctional Laser Printer Printing Technology Lasercartridge Technology Cartridge Technology: Composite/ Separate Drum & Tonertype Of Printing Mono (Black Only), Duplexpaper Size A4/Legalduplexing Feature Yes For Both Print And Scanprint-Speed (A4) - Mono (Ppm) Min. 29 Ppm Or Higherscanning Feature Yesscan Auto Document Feeder Capacity Min. 30 Sheets Or Highermemory/Ram Size (Mb) Min. 256 Mb Or Highernetwork Connectivity Yestype Of Network Interface Ethernet 10/100Wireless Connectivity Yesno Of Paper Tray Min. 1Paper Tray Capacity Min. 150 Duty Cycle/Month (No Of Prints) Min. 20,000 Or Higher 12 Notice Board 3*4 Size Pinup Board 13 Sinewave Invertor 3 Kva With 150 Amp Tubular Battery With 2 Hr Backup Time Min 14 Led Screen 6X3 For Indoor 15 Led Screen 6X4 For Indoor 16 Digital Electronic Display Size 6*1.5 17 Bench Top Single Beam Uv Spectrophotometer 340-999 - Covers 190To 1100 Nm 4 Position Cuvette Holder Automatic Wavelength Selection 128X64 Graphical Lcd Printer Interface Usb Computer Interface With Professional Scanning Software Specifications : Wavelength Range : 190 - 1100Nm, Spectral Band Width : 18 Orbital Shaking Incubator: Size 580* 600 Mm Shaking Speed Range 20 To 250 Rpm Voltage 220-240V External Dimensions 800*1150*1300 Mm Chamber Volume 215 Ltrs 19 Manual Baby Mini Power Pack: Manual Bio World11 X 10 X 6 Cm (L X W X H)50 V100Ma 20 Mini Horizontal Gel Electrophoresis System: 1 Microtome Dimensions2. 300-400Mm3. Alloy Steel4. Min. 1Micron5. External Size 6.450Mm-350Mm 7.Thickness8.Max.60 Micron9.Trimming Thickness Range 10.10Um-40Um11.Vertical Stroke 21 Advance Rotary Microtomy (Latest Spencer ‘820’ Type ) (With Razer): 1. Microtome Dimensions2. 300-400Mm3. Alloy Steel4. Min. 1Micron5. External Size 6.450Mm-350Mm 7.Thickness8.Max.60 Micron9.Trimming Thickness 22 Compound Microscope: Type: Compound Microscopes.Head: Trinocular 30º. 360º Rotating. 48-75Mm Interpupilar. +/- 5Mm Diopter On Left Tube.Objective Magnification: Semi Plan 4X/0.10, 10X/0.25, S40X/0.65, Oil Immersion Objectives. 23 Laboratory Hot Air Oven: 1. Inner Size (Wxdxh)2.Heat Load3.0.75 Kw, 1.50 Kw, 2.25 Kw4.No. Of Shelves 2 5.Temperature Range 6.50Oc - 200Oc+/-2Oc 7.Insulation8.Mineral Wool9.Safety Device 10.Thermostat 11.Temperature Controller 12.Temperature Display13.By L-Shaped Glass Thermometer 14. Electrical Supply15. 220/230V Ac, 50/60Hz 24 Laboratory Eggs Incubator (Capacity 80 Lit):1.Temperature Range Ambient +5 To +90°C 2.Temperature Uniformity + / - 0.35°C At 37°C 3.Temperature Control Thermostat4.Display Thermometer5.Door Solid Door W/ Glass Window & Lock6.Exterior Ms Painted7.Interior Aluminum8.Safety Features Over-Temperature Thermostat9.Shelves Aluminum10.Power Supply 220 Volts 11. Optional - Caster Wheels12.Digital Timer 13.Fluorescent Lamp14. Incubation Of Co2 Air Mixture15.Combined Digital Temperature & Humidity Controller 25 Ph Meter (Digital) :1. Range Ph : 0 To 14Ph2. Mv Measurement : 0+/-1999 Mv3. Resolution Ph : 0.014. Accuracy Ph : 0.015. Calibration :Three Point Calibration6. Display : 4 Digit Led Display7. Power Supply: 230V Ac 50Hz +/- 10% 8.Temperature Range : 0 To 100 Degree C9. Standard Buffer Capsules : 4,7 &9.2Ph Buffer 4,7 &9.2 Supplied10. Operating Manual : Operating Manual 11.Electrode :1 Set Of Electrode, Stand & Clamp 26 Conical Flask 200 Ml :Insufficient Number Available 27 Electronic Balance : 1.Kern Pcb 6000-0Feature2.Ce Compliant Material3.Stainless Steel Platform4.Ac/Dc Input5.100 - 240 V Ac, Universal Plug Set 28 Gel Electrophoresis Assembly With Digital Power Pack :Dimension : 19.5Cm(L)X28.5Cm(B)X6.5Cm(H) Number Of Samples : 52Buffer Volume : 600Mlnumber Of Casting Tray :7X5Cm,13X6Cm,13X10Cm (1 No. Each) Number Of Combs : Multichannel Pipette Compatible Combs Height Adjustable Combs26-Wells 1.5Mm Thickness Comb (Well Width-3Mm,Interspace- 1.5Mm) (2 Nos.)No. Of Platinum Electrodes : Positive And Negative (Each One) Buffer Chamber With Safety Lid : 1 No.Gel Caster : 1 No. 29 Thermal Cycler :1.Europlug2.220-240 V, Europlug Feature3.Ce Compliant Usb Interface4.Eppendorf® 53840000125.Temp Measuring Range Accuracy: ±0.5 °C (At 20-45 °C) Parameter 6.24-100 °C Temp. Range7.300–1,500 Rpm Speed (Mixing)8. W × D × H 20.6 Cm × 30.4 Cm × 17.0 Cm9. Capacity 10 Holds 1 Block10.Stirrer Diam. 3 Mm Weight 6.3 Kg 30 Cooling Centrifuge :230 V Ac, Uk Plug Featurece Compliant To Hold 24 1.5/2.0 Ml Micro-Centrifuge Tubes Corning 6767-Hs Parameter 13300 Rpm16300 × G Technique(S) Centrifugation: Suitable L × W × H 23.5 Cm × 29.3 Cm × 21.6 Cm Weight 31 Gel Documentation Unit With Computer :64 Mega Pixel Camera 32 Micropipette :12 Channel10-100 Ltwelve Channel Variable Micropipette 0.5 Ml 33 Tips Of Micropipette :Round Polypropylene Tip100-1000Hl C3 Variable Volume Single Channel Micropipette Mechanical (02 Each) 34 Eppendorf Tubes :Safe Lock Tubes With Lid& Latch With Graduation Material Polypropylene(02 Each) 35 Pcr Tubes:Micro-Centrifuge Tube 0.2 Ml With Cap , Transparent , Pack Size - 1000 Pcs Thin-Wall Polypropylene Pcr Tubes With Attached Flip Caps For Labeling, Full-Height Wells. The Thin-Walled Polypropylene Tubes And Caps Have Tight Seals And Can Therefore Be Used For Low Reaction Volumes. 36 Deep Freezer: 1. Capacity Cooling (Ltrs) 5502.Temperature Range -18 Degree To -24 Degree C 3.Electrical Power Supply4.Electrical Power Supply Na5.Packing Delivery& Taxes 6.Capacity:527Liters. 7.Dimensions(Mm):920 8.Height X 1425 Width X 690 Depth 37 Laminar Air Flow :Material : Stainless Steel 38 Ph Meter1.Ph Range -2.00 To 16.00Ph.2.Big Screen & Large Lcd Display.3.With White Backlight.4.Memory - Up To 100 Readings.5.Usb Interface.6.0.01Ph Resolution.6. 3 Points Calibration 39 Soxhlet Apparatus With Heating Mantle:Item Weight 9 Kg 500 Gpackage Dimensions 67 X 34 X 31 Cm; 9.5 Kg 40 Autoclave :Surgical Sterilizer Aluminum Portable Auto Clave - 12X14 =24 Lt 41 Bottle Top Dispenser With Dual Inte Technology :Bottle Top Dispenser- Volume Range 0.5- 5 Ml Type Of Product : Ultimus Bottle Top Dispenser Coefficient Of Variation ±Ml 0.01 ±Mlambient Temperature : 20°C Increment : 0.1 Ml 42 Centrifuge :Item Weight 3 Kg 810 Gproduct Dimensions 20 X 21 X 26 Cm; 3.81 Kg Item Part Number Centfitem Height 26 Centimeters Item Width 21 Centimeters Wattage 150.00 43 Digital Chemical Balance :Surplus External Two Pan Laboratory Balance Weighing Scale Type- Bench Scale Material-Steelproduct Type Digital Analytical Balance Weighing Machine Monitor Display-Digitalpower Supply-Electric 44 Double Door Refrigerator :Net Total(Liter)322Net Width(Mm)600 Mmnet Case Height With Hinge(Mm)1715 Mmnet Depth With Door Handle(Mm)672 Mm Net Weight(Kg)59 Kg 45 D.O. Meter :Net Total(Liter)322Net Width(Mm)600 Mmnet Case Height With Temperature Range -5.0 To 50.0°C (23.0 To 122.0°F)Temperature Resolution 0.1°C (1°F)Temperature Accuracy ±0.2°C (±1°F) (Excluding Probe Error) Do Probe Hi 76407 With 4 M (13) Cable (Included)Automatic Shut-Off After Approx. 8 Minutesbattery Type/Life 1.5V Aa (4) / Approx. 500 Hours Of Use Environment 0 To 50°C (32 To 122°F); Rh Max 100% Dimensions 196 X 80 X 60 Mm (7.7 X 3.1 X 2.4 In.)Weight 500 G (1.1 Lb.) 46 Digital Ph Meter With Electrode (Lcd Display):1. Range Ph : 0 To 14 Ph2. Mv Measurement : 0+/-1999 Mv3. Calibration* :Three Point Calibration4. Buffer Recognition : Manual& Automatic5. Display : 4 Digit Led Display6. Parameters Displayed : Ph & Mv7. Power Supply : 230V Ac 50Hz +/- 10%8. Standard Buffer Capsules : 4,7 &9.2Ph Buffer 4,7 &9.2 Supplied9.Electrode :1 Set Of Electrode, Stand& Clamp 47 Digital Photoelectric Colorimeter :Type : Digital Photo Colorimeter Resolution : 0.01 Aabsorbance : 0- 1.99Aphoto Detector : Silicon Photodiode / Photo Cell Display : 2 Digit Led 48 Digital Potentiometer :Technical Specifications : Range 0 To  199.9 Mv 0 To  1999 Mv Resolution 0.1 Mv Repeatability  1 Mv Accuracy  1 Mv  1 Digit Operating Temperature 10 C To 45 C Display 3 Digit 0.5 Seven Segment Led Display With Auto Polarity Indication Power 230Vâ 10% Ac, 50 Hz. Dimensions 275 190 78Mm Weight2.5 Kg. (Approx) Standard Accessories Platinum Electrode : 1 No. Reference Electrode : 49 Distillation Apparatus:Spinning Band Typesteflon - Operates Up To 225 °C Stainless Steel – Operates Above 225 °C High Efficiency And High Temperature Bands Maximum Theoretical Plates Optional: 4 Place Or 8 Place Automatically Collect Fractions According To Vapor Temperature Vacuum Operation Optional Vacuum System 100-1 Mmhg Range Other Ranges Availableautomatic Control Of Vacuum Level. Vacuum Reduces Boiling Points. Ideal For Thermally Sensitive Samples Or High Boiling Materials Automatic Controller Provides Automatic Control Of The Entire Distillation Process Start The Distillation And Walk Away Pc Optional Control From Pc Perform A Distillation From A Pc Analyze Distillation Results Using Our “Data View” Program. Safety Marks Ce Marked Listed To Ul 6101.1 By Etl Listed To Csa C22.2 1010.1 By Etl C Tick (Australia/Nz)Safe For Laboratory Use Power (Distillation Unit Only) 1-22 Liter (115 V) 15 Amps 1-22 Liter (220 V) 8 Amps50 Liter (220V) 15 Amps Configured For Local Power Requirements And With Local Power Plug, 115 Or 220 V, 50/60Hz 50 Dryer And Temperature Controller :Applicationair Dryer & Freezers. General Specificationstemperature Range -50°C To 99°C.230Vac Standard. Other Models With 12Vdc, 24Vdc, 110Vac On Request. Panel Cutout: 29 X 71 Mm. Screw Terminals: Admit 1X2.5 Mm2 Wires. 51 Blower :Item Weight: 850 Gitem Dimensions Lxwxh: 20 X 40 X 20 Centimetres Net Quantity: 1 Countgeneric Name: Electric Air Blower 52 Chemical Thermometer :Included Components Thermometer Outer Material Glassspecification Met Ce Display Type Analogitem Length 30 Centimetersupper Temperature Rating 300 Degrees Celsius Response Time 500 Millisecondsreusability Reusableimmersion Depth 30 Centimeters 53 Calorie Meter Working (Operating) Temperature 15-70°Cresults Per Hour 10 Samples Per Hour Using 2 Oxygen Bomb Vesselsmeasuring Range Max 99Mj, 99,000,00 Joules Working Temperature Min 1°Cworking Temperature Max 50°C Oxygen Operating Pressure Max 40 Barbalance/Scale Interface Rs232, 1200 To 38400 Baud (Settable) 54 Beaker- 50Ml, 100Ml, 250Ml, 500Ml, And 1000Ml, Catering To Various Volume Crafted From High-Quality 3.3 Borosilicate Glass, The Low- Form Design With A Wide Base And Tapered Spout. 55 Funnel :A 125Mm Length Stem. Stem Has Diameter Measuring 16Mm. 56 Pipette :Laboratory Application Area, India Country Of Origin, 915 Mm Overall Length, Twisted Galvanized Iron Wire Material, 1 Pc Pack Of, Hard Nylon Bristles, 150X25 Mm Head Size. 57 Burette :Accuracy As Per Din Iso 385 Standardglass Key, 50 Ml Burette, Borosilicate Glass 3.3 Class-A, White Graduation 58 Burette Stand :Dimension Of Base: 300X150X30Mm. Rod: 700X10Mm. 59 Mortar Pestel:125Ml Capacity And Is 85 Mm In Diameter. The Pestle Is 95 Mm Long 60 Electronic Balance :Single Pan Balance 5 Weighing Capacity: 220 Gm Or More 6 Pan Size: 90 Mm In Diameter Or More 7 Display Readability : 0.1 Mg Or Less 8 Weighing Repeatability: +/- Transparent Three Door Draft Shield- Top As Well As Sides Sliding 17 Input Power Supply Requirements: 240 V 61 Burette Brush :915 Mm Overall Length, Twisted Galvanized Iron Wire Material, 1 Pc Pack Of, Hard Nylon Bristles, 150X25 Mm Head Size 62 Test Tube Brush :High Quality - Made Of Stainless Steel And Nylon Bristles Due To Which Easy To Clean, Will Not Rust. Durable, Strong But Soft Nylon Bristles For Cleaning. This Test Tube Brush Is Specialized Designed For Cleaning Bottle Neck Flasks. 63 Conical Flask :High Quality, Borosilicate 3.3 Glass Conical Flasks Lab Grade & Tested Glass 50 Ml Capacity 64 Volumetric Flask : Capacity Sg-100: 100Ml Sg-250: 250Ml Sg-500: 500Ml Sg-1000: 1,000Mlmaterial Glass Heat Resistance With Graduation 65 Wire Gauze: 120Mm*120Mm 66 Round Bottomed Flask Borosilicate Glass Is Type Of Glass With Silica And Boron Trioxide. Capacity 100 Ml Non Toxic 67 Periodic Table (Poster)140*100Cm 68 Gas Connection And Fitting In New Lab 250 Ft Gas Pipe Line With Rubber Pipe-100 Metre, Burner Brass- 48, Brass Gas Top Two Way 24, Copper Pipe-24 Copper Hos Pins- 24 Brass Line Volwes All With Isi Mark & Installation 69 Water Bath Digital :Water Bath With Selectable Openings 304 Stainless Steel 0.01.Resolution Electric Constant Temperature Water Bath For Lab Commerical.110V - 220V Lxt Panda Lxt Panda Digital Lab Water Bath, Thermostatic Water Bath With Selectable Openings 304 Stainless Steel 0.01.Resolution Electric Constant Temperature Water Bath For Lab Commerical.110V - 220Vless 70 Digital Ph Meter Range 015 Calibration-Ph Ut To 3 Pointtemperature Range 0 To 100C 71 Digital Blood Pressure Machine 1. A Digital Automatic Blood Pressure Monitor, Designed For Accurate And Convenient Monitoring Of Blood Pressure Levels At Home Or In A Clinical Setting.2. The Monitor Features A Large, Easy-To-Read Digital Display Screen That Shows Blood Pressure Readings. 72 Blower :Item Weight: 850 Gitem Dimensions Lxwxh: 20 X 40 X 20 Centimeters Net Quantity: 1 Countgeneric Name: Electric Air Blower 73 Single Needle Lock Stitch Sewing Machine : A3B Needle – Db×1 11-18# Auto Cutter – Yes Auto Reverse – Yes Thread Number – 2 Stitch Length (Mm) – 5 Height Of Pressure Foot – 5-13 Sewing Speed – 5000 Spm (Stitch Per Minute) A/M – Yes Volume (Mm) – 671 X 248 X 550 Power Consumption – 220 V Lubrication – Fully Automatic Lubrication 74 Over Lock /Inter Lock Sewing Machine :1.Application : Suitable For Light To Medium Fabric2.Stitch Type : Chain Stitch3.Needle Light : Led Type-3 Step 4.Differential Feed Ratio : 0.7 ~2.05.Needle System / Size : Dcx1# 9~146.Nos Of Loopers : 27.Nos Of Thread : 4 8.Lubrication Type : Automatic9.Stitch Length : 3.6 Mm10.Stitch Width : 4/6 Mm11.Feed Type : Differential 12.Pressure Foot Height : 5 Mm13.Up / Down Needle Position : Yes14.Sewing Speed Adjustments : Yes
Contract Date: May 18, 2026 Contract Value : 1.46 Crore
Local Bodies No of Bidders 4
Madhya Pradesh View Result →
TenderDetail
Loading tenders