View Bid Results For Hdpe Feeder Tenders

We found 737 Bid Results related to hdpe feeder tenders. You can find Contractor details who won hdpe feeder tenders along with contract details in Bid awards announcements section.

Filters
Stage
468
138
131
Tender Publishing Platform
29
708
State / UT
30
137
114
110
66
46
40
29
22
19
18
16
15
14
13
11
10
9
8
8
8
4
3
3
3
3
2
2
2
1
1
Contract Value
274
142
187
134
Publish Date
3
0
0
0
0
Sector
22
146
144
128
71
67
67
44
17
9
9
7
5
4
3
3
3
3
2
2
1
1
1
Ownership
4
446
142
91
58
Within keyword
Active filters:
Showing 1–15 of 737 tenders matching your filters
1.
Information and Broadcasting #11422661 AOC
Bids Are Invited For Sitc Crs Radio Station Transmitter Of 50 W Fm Set , Sitc Of Self Supported Transmission Tower , Vhf Transmitting Antenna , Low Loss Feeder Cable With N Connector , Studio Monitor Speaker , On Air Broadcast Console Etc , Dynamic Cardioid Microphone , Portable Solid State Field Recorder , Headphones , Broadcast Audio Processor , Dummy Load With Connector , Extra Lightening Protection Circuit , 19 Equipment Rack Ht 5 Ft Mts Equivalent , Work Station With Antivirus For 3 Years , Audio Editing Software , Automation Scheduling Software Licence , Condensor Microphone With Wind Filter And Arm Stand , Audio Distribution Amplifier , Headphone Distribution Amplifier , 10 Kva Online Ups , Xlr 6 Microphone Junction Box , Professional Audio Line Cable , Professional Microphone Cable , Xlr Connecter Male And Female , Trs Stereo Connecter , Professional On Air Studio Light , Digital Clock With Time , Supply And Fixing Of Work Station Table , Supply And Fixing Of Vob Table , Supply And Fixing Of Discussion Table L Shape , Supply And Fixing Of On Air Table And Side Table , Supply And Fixing Of Shoe Rack , Supply Of Low Frequency Acoustic Treatment , Supply Of Acoustic Treatment , Teak Board Skirting , Supply Of Observation Window , Supply Of Observation Window2 , Supply Of Sound Proof Door With Frame Chaukhatt , Supply Of Executive Chairs Revolving, Standard , Supply Of Visitor Chairs Revolving, Standard , T.V 56 Inch Standard Led Type Ips Panel , Sitc Of Vrv Vrf 10.0 Hp Odu , Sitc Of Cassettee Unit 1.0Hp , Sitc Of Cassettee Unit 1.5Hp , Sitc Of Cassettee Unit 2.0Hp , Sitc Of Remot , Supply, Installation, Testing And Commissioning Of Y Joints , Supply And Fixing Of Refrigent Copper Pipe With Insullation , Supply And Fixing Of Refrigent Conduit Pipe 25Mm Pvc , Internet Works Sitc Of Optic Fibre Cable 6 Core Sm , Sitc Of Patch Cord Ofc - 3 Meter Sc-Lc , Sitc Of Pigtail Ofc - 1 Meter , Sitc Of Cat-6A Cable , Sitc Of 19 Inch 6 U Rack , Sitc Of Lan System , Sitc Of Liu 12 Port , Sitc Of Patch Cord Cat-6 -1 Meter , Sitc Of Patch Cord Cat-6 -2 Meter , Sitc Of Patch Cord Cat-6 -10 Meter , Sitc Of Hdpe Pipe , Supplying And Fixing Io Box Alongwith Base And Cover Plate , Sitc Of Cctv Camera With Night Vision - 5 Mp , Supply And Fixing Of Cat-6 Wire In Pvc Conduit , Sitc Of Cctv Camera , Fire Work Sitc Talk Back Slave Station , Sitc Smoke Detector With Built In Led , Sitc 6 Kg Powder Type Fire Extinguishers , Citc 2 Kg Powder Type Fire Extinguishers , Sitc Addressable Manual Call Point Complete As Required. , Civil Works As Per Boq , Cement Work As Pe Boq , Providing And Laying In Position Cement Concrete Of Specified Grade , Double Charge Vitrified Tiles , Centering And Shuttering , Steel Reinforcement For R.C.C. Work , Smooth Finishing Of The Exposed Surface Of R.C.C. Work , Brick Work With Common Burnt Clay , 12 Mm Cement Plaster Of Mix , Partition Upto Ceiling Height , Cement Fiber Board , Frames Of Doors, Windows, Clerestory Windows , Isi Marked Flush Door Shutters , Universal Hydraulic Door Closer , Structural Steel Work , Polishing In High Gloss Matt Finish Melamine , Bright Finished Brass Hanging Type Floor Door Stopper , False Ceiling With Cove And Design At All Height , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint , Providing And Applying White Cement Based Putty , Wall Painting With Acrylic Emulsion Paint , 2Mm Thick Pvc Mat Finished On Floor Of Approved Design , Ac Duct Made Of Wooden Batten , Sitc Of Vertical Blinds , Electrical Works , Wiring For Light Point Etc , Wiring For Circuit , Supplying And Fixing Following Modular Switch Etc , Supplying And Fixing Following Modular Switch Socket , Supplying And Fixing Following Modular Switchs , Supplying And Fixing Modules , Supplying And Fixing Following Way , Supplying And Fixing Miniature Circuit Breaker , Miniature Circuit Breaker Suitable For Inductive Load , Supplying And Fixing Single Pole Blanking Plate , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit , Supplying And Fixing Suitable Size Gi Box Wih Modular Plate , Frls Pvc Insulated Copper Conductor , Frls Pvc Insulated Copper Conductor 2 , Frls Pvc Insulated Copper Conductor3 , Frls Pvc Insulated Copper Conductor,4 , 3X2.5 Mm Flexible Wire For Connection , Wiring For Group Controlled , Led 2X2 Luminaire 36W , Recess Mounted Led Downlighter , Wall Fan With Brush Less Direct Current Bldc Total Quantity : 7162
Contract Date: Ref. Documents Contract Value : 1.21 Crore
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : 8.05 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 12.10 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 15.56 Lakh
Government Departments No of Bidders 4
Uttar Pradesh View Result →
6.
Water Resources and Irrigation #11319368 Price Bid
Tender for Supplying Installation Testing And Commissioning Of 90 Watt Led 6000K Asymmetric New Generation Energy Saving And Environment Long Life Versatile Pressure Die Cast Aluminum Ip66 Roadway Luminaries With High Power Led Light Source Complete Etc. As Required Housing Reflector And Enclosed With Toughened Glass Complete With All Accessories, Philips/Bajaj/Crompton/Halonix/Havells. , Repairing And Installation Of Exisiting Defective Street Light With Replacement Of Drivers, Retifier, Led Plate Etc. Complete As Required At Site. , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. A) 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade Of Following Size Etc Complete As Reqd. A) 4 X 16 Sq. Mm , Supplying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade Of Following Size Etc Complete As Reqd. B) 4 X 25 Sq. Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. (I). 3X2.50 Sqm. , Supplying And Erection Of Flange Mounted Hot Dip Galvanized Octagonal Poles Of 8 Mtr. Height Made From 3Mm Thick Steel Plate Having Bottom Dia Of 130 Mm & Top Dia Of 70Mm Complete With Window With Flash Cover At The Height Of 2.00 Mtr From The Base Of Cable Termination Block Etc. And Galvanization Base Plate Of Size 250Mm X 250Mm X16mm Thick On Existing Cement Concrete Pedestal As Required Including Suppling And Fixing Of Laminated Sheet, Din Channel, Bus Bar And Earth Sheet 2 Nos. Welded At Suitable Height As Per Direction Of Enginer-In-Charge. 2 Nos. Washer, Nuts And Locking Arrangement Completed As Required (Make Bajaj/Volmont/Phillips/Lysaght/Consoul) , Supplying & Fixing Of Following Size Aluminium Thimble With Proper Connection And Pvs Tape Etc As Required. 16 Sqmm , Supplying & Fixing Of Following Size Aluminium Thimble With Proper Connection And Pvs Tape Etc As Required. 25 Sqmm , Fabrication Supplying And Installation Of Outdoor Type Cubical Feeder Pillar Of Suitable Size Not Less Than 30 Cm And Upto 45 Cm Deep Made Out Of M.S. Sheet 2Mm Thick (14Swg) Duly Compartmentalized Having 4 Strip Busbar Of 200 annual periodical maintenance Capacity Double Door With Locking Arrangements For Protection From Rain Dust Duly Fixed On M.S. Angle Iron Frame Work Of Size 50 Mm X 50 Mm X 6 Mm (Ns) 110 Cm Long Legs Out Of Which 50Cm Duly Grouted In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Agreegate 20Mm) Having Following Accessories Mounded Inside The Cubical Panel Including Connection Inter Connection/Soild With Aluminum Timbles Earthing With Two Nos. Earth Studs Duly Painted With One Coat Of Red Oxide And Two Coats Of Superior Quality Enamel Paint Completed Etc. As Required Having Also Compartment For Energy Meter. Supplying And Fixing Of Following Accesssories In The Existing Cubical Panel Board/Feeder Pillar Including Connection Testing Etc. As Required Having Also Compartment For Energy Meter Supplying And Fixiing Of Folowing Accessories In The Existing Cubical Pnal Board/Feeder Pillar Including Connection Testing Etc. As Required Incomer 125 annual periodical maintenance .35Ka Mccb With Thermal Release 1 No. Outgoing A) 63Amp - Dpmcb - 6 Nos. B) 63Amp - Elcb - 1 Nos. C) C.T. Opetrating . D) Tongal Switch E) Voltmeter 0-5000 Volts 96 Sqm Flush Type With Selector Switch F) Ampere 0-100/5 Sqmm Flush Type With Selector Switch & 100/5 annual periodical maintenance Ratio Cts G) Indication Lamp (Ryb) With Control 3 Pole (Ml-6) 95 annual periodical maintenance H) Power Contactor 3Pole (Ml-6) 95 annual periodical maintenance I) Auto Timer Rex Modular D41 Model Mds Make J) Danger Notice Plate. , Supplying And Drawing Following Sizes Of Pvc Sheathed & Xlpe Insulated Al. Conductor Multicore Unarmoured Cable Of 1100 Volts Conforming To Is 7098 (Part 1) 1988 With Upto Date Amendments In The Existing Panel Ets As Required.. A) 3 Core 4 Sq.Mm , Supplying And Fixing 4 Nos. 16 Mm (Minimum) Dia X 650 Mm(Minimum) Long Gi Foundation Bolt (En8grade) With Nuts, Washer Including 2 Nos. Template Of 3 Mm Thick Size 200 X 200 Mm. With 4 Nos. 20 Mm. Dia Holes (Or Suitable For Existing Holes), To Match With Pcd Of Pole Base Plate As Required. , Fabricating, Supplying And Fixing Of Wire Mesh Protection Frame Work Fabricating With 40 X 40 X 6 Mm Thick Angle Iron/Tee Iron Having Intermediate Members Of Size 25 Mm X 6 Mm (Gi Wire Should Be 6Swg) Flat Strip Welded At 30 Cm In Each Sections & Duly Welded With Hard Drawn Wire Fabric Mesh Of Size 25 Mm X 75 Mm Having Weight Not Less Than 7.5 Kg/Sqmtr. And Making Main Door Gate Provided With Two Nos. Sliding Bolt With Godown Locks With Operating Hadle Welded From Inside Of The Door I/C Providing And Fixing Of Four No. Legs Of Same Angle Size Of 90 Cm Length Duly Grouted In Foundation (30 X 30 X 45) Cm (Deep) In 1:2:3 Cement Concrete & Painting With One Coat Of Red Oxide & Two Coat Of Super Synthetic Luminous Paint Of Approved Colour And Quality Etc.Complete As Reqd. {Area Of Hard Drawn Wire Fabric With Angle (Except Legs) Shall Be Measured For Payment} , Fabrication, Designing, Supplying & Fixing Of 1000 Mm Long Double Arm Bracket(Thickness Minimum 3Mm) Over Hang With Tightening Bolt Etc. As Per Design Approved By Engineer-In-Charge. , Providing And Fixing Of Locking System Of Street Light Including Pole Door For Safety Cover Plate Of M.S Sheet Including Weilding, Nut-Bolt Etc. And Painting Of Door Cover Plate With Synthetic Enamel Aluminium Paint. , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- 63 annual periodical maintenance - Dpmcb , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- 125 annual periodical maintenance Tpn , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- 63 annual periodical maintenance - Mccb , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- Ct Operating , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- Tongal Switch , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- Power Contactor 3 Pole (Ml-6) 95 annual periodical maintenance , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- Ampere 0-100/5 Sqmm Flush Type With Selector Switch & 100/5 annual periodical maintenance Ration Cts , Supplying, Installation, Testing And Commissioning Of The Following Material Required For Existing Feeder Panel Including All Accessories For Connetion Etc As Per Site Requirement:- Timer Into The Existing Street Light Panel Box Including All Accessories For Connection Etc. As Per Site Requirement. , Providing And Laying In Position 1:2:4 Reinforced Cement Concrete Foundation Of Size 500 Mm.(L) X 500 Mm. Wide And 1200 Mm. Deep I/C Excavation Of Earth In Hard Rock, Providing Cutting, Bending And Placing In Position, Steel Reinforcement Of Cold Twisted Bars Of 12 Mm. Dia- 1300Mm Long (Approx)- 8 Nos. And Reinforcement Ring Of Cold Twisted Bar Of 8Mm Dia - 2000Mm (Approx) - 10Nos. (With Equal Spacing) For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete As Required With Positioning Of Foundation Bolts (As Per Item Below) And Providing 63 Mm. (O.D) Dwc, Hdpe Pipe Minimum 1 Mtr. For Cable Entry & Exit As Required. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level A) 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. A) Upto 35 Sqmm , Repairing Of Defective/Faulty Cable Connection Inside The Pole Window And Underground Cable By Making Connection With Suitable Size Pvc Insulated Copper Wire, Connector Plate, Thimble And Taping With Insulation Tape For Existing 5 Mtr. To 12 Mtr. Height Gi Pole I/C Testing & Commissioning Etc. Complete As Required At Site , Laying Of Al. Conductor Armoured/Unarmourd Power Cable 1.1 Kv Between Pole To Pole With The Help Of Tower Wagon, Including Supplying Of 10 Swg Gi Wire, In Following Manner, A) Upto 3.5X35 Sqmm. Overhead Tied With Suitable Size Schakle Clamp And Insulator , Painting By Double Coating Aluminium Silver Paint Of Street Light Poles Of Height 8 Mtr Sizes I/C. Pole Brackets Of Various Designs After Cleaning And Scrabbing Of Poles For Removing Of Any Posters/Rusts If There To Give Even Shade Etc. As Reqd. , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Supplying And Laying 25Mm X 5Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt,Spring,Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) , Excavation For Cable Trenches In Soft Soil, Depth Upto 1.2 M Including Dressing Of Sides Lift Upto 1.5 M, Including Getting Out The Excavated Soil, Refilling With Sand And Or Good Soil After Laying Of Cable/ Pipe Etc In Layers Of 20 Cm, Ramming, Watering And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required , Deployment Of Hydra Crane With Boom Lift Cage Bracket Or Other Arrangement Of Required Capacity With Fuel And Driver Fro Fixing/Removal/Replacement Of Lights Mounted On Pole, Bracket, Electric Wiring Pole, Pole Window Accessories Etc. As And Required As Per Direction Of Engineer In Charge. , Deployment Of 01 No. Skilled/Wiremanm And 01 Nos. Unskilled Worker/Helper For Day To Day Maintanence, Repairing And Watch &Ward Of The Street Light On The Bundh Roads From Dhansa To Jhatikra For 01 Year Of I&Fc Deptt. , Deployment Of 01 No. Skilled/Wiremanm And 01 Nos. Unskilled Worker/Helper For Night Shift For Maintanence, Repairing And Watch &Ward Of The Street Light On The Bundh Roads From Dhansa To Jhatikra For 01 Year Of I&Fc Deptt.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
7.
Power #11314306 Price Bid
Tender for Installation Of 63 Kva & 100 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (56 No. Work) (Dpr N0. 137,138,141,142,143,144,145,146,147,148,149,150,151,152,153,154,155,156,157,158,159,160,161,152,163,164,165,166,167,168,169,170,172,173,174,175,176,177,178,179,180,181,182,183,184,185,186,187,188,189,190,191,192,193,194,195) , Carriage Of All Petty Material Of All 56 Estimate, (Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 63Kva/100 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Weasel Conductor, From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Lt Abc 3X120+1X95+1X16 Sqmm From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Dropper Channel (56Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 125X65 Sqmm And Febrication Of Top Channel/ Dropper Channel For Fuse Set / T-Off Channel (112Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 125X65x6 Mm And Febrication Of Base Angle For Substation 63Kva/100Kva (112Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 63 Kva/100 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm By Providing Suspension Clamp Dead End Clamp, I-Hook Etc And Completion Work Properly, As Per Respo Norms, And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60Xo.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv. Fuse Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Lt Fuse Set Protection Unit For 100 Kva Tf With Smc Box Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of 3-Phase Distributiong Box All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Installation Of 250 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (02 No. Work) (Dpr No. 140 & 171) , Carriage Of All Petty Material Of 02 Estimate, (, Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 250 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Dropper Channel(4Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 125X65 Sqmm And Febrication Of Top Channel/ Dropper Channel For Fuse Set / T-Off Channel (4Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Safely Installation Of 250 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth, As Per Direction Of Site Incharge. , Laying Of Lt Pvc Cable Al 1X400 Sqmm By Porviding Al Lug And Panching With Cremping Tool Complection Work Properly, As Per Respo/Norms And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Construction Of Tif Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mt.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Erection & Fixing Of 11Kv. Fuse Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Construction Of Safety Fencing (Ms) For Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50mm) 4 Sqmm Dia M.S. Gi Wire Mess Corrosion Free Made Of Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Anglen-Iron To Be Fitted On Vertical Posts. Pickets (I Required) Fitted To Rail And Gate To Facilitate Entry And Exit With Lock. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Gi Angle 75X75x6 Mm Corrosion Free. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Metalic Materilas Should Be Galvanized & Corrosion Free) , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Propviding And Intallation All Requrment For Earthing Of Neutral By Boring And Lowering Of G.I. Pipe Size 32 Mm Dia... Into The Ground Up To Water Level 80 Fit. With The Lower End Of Solid Copper Cone Approx. 225Mm Long And 750 Gm. In Weight Shall Be Provided And In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg From The Cone Up To The Ground Surface Where It Will Bc Bolted To The Nf.S. Earth Strip For Tif Neutral Connection, The Earth Strip *Vill Be Welded To The G.L. Pipe And Neutral Earthing Support, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Capacity Increasing 10/16 Kva To 25 Kva Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (18 No. Work) (Dpr No. 740,741,742,743,744,745,746,747,748,749,750,751,752,771,773,833,834 & 891) , Carriage Of All Petty Material Of 18 Estimate, (Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 25 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Weasel Conductor, From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Erection Of Single Pole Structure With Exsiting Single Pole And Making It Double Pole All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Top Channel/Dropper Channel(36Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 125X65x6 Mm And Febrication Of Base Angle For Substation 25Kva (36Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 25 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Safely Removal Of Old & Used 10/16 Kva Transformer With The Help Of Crane/Manual Labour From Lt Sub-Station Double Pole/Plinth And Carrige Site To Store Hapur As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Specification, Quantity And Price Schedule For Replacement Of 33Kv Line Jindal Nagar Jarjar Line And Feeder Bifurcation 1Ikv Feeder No- 1 Reliance Road In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Pilkhuwa Under Edc Hapur. (02 No. Work) (Dpr No. 70 & 16) , Carriage Of All Petty Material Of 02 Estimate From Electricity Store Center Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Dog Conductor Of Estimate From Je Store/Ctr/Esc Hapur To Site Of Work, Including Loading & Unloading At Both Ends, As Per Direction Of Site Incharge. , Carriage Of All Type Cable Of Estimate From Je Store/Ctr/Esc Hapur To Site Of Work, Including Loading & Unloading At Both Ends, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 11 Mtrs. Long From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 11 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Angle, E-Bracket, 11Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Nomrs By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Jumpering Etc Work And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, Fixing Of M.S. Top & Dropper Channel, M.S. Angle, E-Bracket, 11Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Nomrs By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Jumpering Etc Work And As Per Direction Of Site Incharge. , Erection & Fixing Of Single Plain Cement Concrete Pole 8.50 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing/Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm, Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Top Channel/Dropper Channel/T-Off Channel/Bracket Channel Suitable For Dp/Single Pole For Pcc/Stp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 65X65x6 Mm And Febrication Of Bracket /Bracing Angle Suitable For Dp/Single Pole For Pcc/Stp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of Single Plain Cement Concrete Pole 11 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing/Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, As Per Direction Of Site Incharge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor By Providing Holding Clamp, Nut & Bolt E-Bracet If Reqired As Per Respo/Drnwing Nonns And As Per Direction Of Site Incharge , Grouting & Fixing Of Stay Rods (20Xl800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30) M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I.Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of Plain Cement Concrete Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 33 Kv 3X300 Sq.Mm Xlpe Cable And Lt Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11 Kv Cable Jointing Kit 3X185 Sqmm, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , Making And Fixing Of Side Breckit By Ms. Channel, Ms Angle By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Erecetion Of 11 Kv V-Type Crross Arm By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Providing And Trcnchless Laying (90X2=180 Mtrs. Double Circuit) Of 140/160Mm O/D Pn-4Pe-80 Pn-4 Grade Uv Stabilized Hdpe Pipe As Per Is Of 6 Meter, For Laying Of Underground Cable As Per Respo/Norms, Including Cost Of Above Hdpe Pipe, Es Per Direction Of Site Incharge. , Laying Of 11 Kv Xlpe Cable 3X185 Sqmm, Undergound (110X2=220 Mtrs. Double Circuit) Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape Al Both Ends As Per Respo/Norms And As Per Direction Of Site Incharge , Providing And Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Clamps, Nuts & Bolts Etc.) As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Barbed Wire, As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Stone Pad 300X300x75 Mm, As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Number Plate As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Pg Clamp, As Per Respo/Norms And As Per Direction Of Site Incharge. , Errection Of Brecing Set 4.3X4.3 Mtr Angle Iron 65X65x6 Mm By Providing Holding Clamp, Nut & Bolt As Per Respo/Norms And As Per Direction Of Site Incharge. , Dismantling Of Existing 33 Kv Line And Jarjar Conductor And And Bundling Same Including Carriage Of Above Material Form Site Of Work To Je Store/Esc-Hapur, With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo/Norms And As Per Direction Of Site Incharge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
8.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
10.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
11.
Power #11269168 Price Bid
Tender for Carriage Of Following Material Of Estimate, From Electricity Store Center, Hapur To Site Of Work With Loading, Unloading Multiple Handling, Staking,Labour,T&P And Transpotation At Both Ends On Kachha/Packka Road, As Per Direction Of Site Incharge From Je Store/Store Center Hapur/Ghaziabad/Bulandshar (0-50 Km) Complete In All Respects. , Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit , Cable Box 3X185 O/D Sqmm 11 Kv , 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake , 11 Kv Fuse Set , Plain Cement Concrete Pole 8.5 Mtr Long. , 11 Kv Pin Insulator Polymer , 11 Kv Disc Insulator Polymer , M.S. Channel 100X50x50 Mm , Earthing Complete , 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit , 11 Kv O/D Xipe 3X300 Sqmm C/J Kit , 11 Kv Through 3X185 Sqmm Xlpe C/J Kit , 33 Kv Circuit Breaker 800A, 750 Mva , Acsr Dog. Conductor , Cable Ht Xipe 3X300 Sqmm 33 Kv , Cable Box 3X300 O/D Sqmm 33 Kv , H/S 33 Kv 3X300 Sqmm J/Kit St. Th , Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. , 11 Kv Vcb Incoming , 33 Kv Pt Outdoor (2Set) (2X3=6) , Battery Set 24 Volt , Battery Charger 24 Volt , 33 Kv Ct 400/200/1 annual periodical maintenance , 33 Kv Ct 200/100/1 annual periodical maintenance , 33 Kv Control Pannel Double T/F , 33 Kv Fuse Set , Eraction And Fixing And Making Connection Of Following Material (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. , Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit , Cable Box 3X185 O/D Sqmm 11 Kv , 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake , 11 Kv Fuse Set , Plain Cement Concrete Pole 8.5 Mtr Long. , 11 Kv Pin Insulator Polymer , 11 Kv Disc Insulator Polymer , M.S. Channel 100X50x50 Mm , Earthing Complete , 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit , 33 Kv Circuit Breaker 800A, 750 Mva , Acsr Dog. Conductor , Cable Ht Xipe 3X300 Sqmm 33 Kv , Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. , 11 Kv Vcb Incoming , 33 Kv Pt Outdoor (2Set) (2X3=6) , Battery Set 24 Volt , Battery Charger 24 Volt , 33 Kv Ct 400/200/1 annual periodical maintenance , 33 Kv Ct 200/100/1 annual periodical maintenance , 33 Kv Control Pannel Double T/F , 33 Kv Fuse Set , Providing, Supplying, Laying And Installation Of Hdpe Pipe Of Pe-80 Grade, Pn-6, 200 Mm Diameter By Horizontal Directional Drilling (Hdd) / Trenchless Method For Accommodating 11 Kv, 3×185 Sq.Mm Xlpe Insulated, Armoured Cable, Including Execution Of Road Crossing Or Similar Crossings Wherever Required, Complete With Pilot Drilling, Reaming And Pullback Operations, Proper Jointing Of Hdpe Pipe (Butt Fusion/Electrofusion), All Labour, Tools & Plants, Machinery, Drilling Fluid, Safety Arrangements, Formation Of Entry And Exit Pits And Site Restoration; The Contractor Shall Be Fully Responsible For Obtaining Necessary Permissions, Protection Of Existing Utilities And Resolution Of All Right Of Way (Row/Raw) Issues During Execution. , Laying Of 11 Kv Xlpe Cable Of Size 3X185/3X300 Sq.Mm Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge. , 11 Kv Ht Xlpe Cable 3X185 Sq.Mm With Double Circuit , 11 Kv Ht Xlpe Cable 3X300 Sq.Mm With Double Circuit , Providing The Material And Execution Gi Pipe Earthing With 40 Mm Dia B Class Gi Pipe 80 Feet Boar To Water Level For Proper Earthing ( Earthing Resistance Less Than Or Equal To 1 Omh ) At 33/11 Kv Substation With The Help Of 50Mm X 6Mm Gi Strip Duly Welding To Dt Transformer Other Equipment. With Earthing Mess Lug, Nut And Bolt. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing, Supplying And Fixing Of Copper Bus Bar Of Size 80 Mm × 10 Mm Suitable For 11 Kv Vcb Panel, Including Cutting, Drilling, Bending, Proper Alignment, Insulation Clearance, And Secure Fastening With All Required Nuts, Bolts, Washers And Supports, Ensuring Proper Electrical And Mechanical Connections, Complete In All Respects; The Work Shall Include All Labour, T&P Will Be Provided By Contractor In All Respects. , Grouting Of Following Plain Cement Concrete Pole 8.5 Mtr. Long Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Pg Clamps (Parallel Groove Clamps) Of Suitable Sizes For Making Conductor-To-Conductor Connections, Including Dog Conductor To Dog Conductor And Panther Conductor To Panther Conductor Joints, Complete With All Necessary Nuts, Bolts And Accessories, Ensuring Proper Electrical And Mechanical Continuity, As Per Relevant Standards And Directions Of Site Incharge All Labour, T&P Will Be Provided By Contractor In All Respects. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 11Kv Cable Jointing Kit 3X300 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Providing And Fixing 11 Kv Relay, With (E/F & O/C) Of C&S, Ashide, Abb Make With 1&5 annual periodical maintenance Port Suitable For 11 Kv Feeder Pannel As Per Respo/Norms And As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor With All Labour, T&P In All Respects. , Providing And Fixing Of Wti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti , As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Oti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti, As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Vaccume Interupter In 11 Kv Pannel, As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing 33 Kv Ct Stracture As Per Respo/Norms And As Per Direction Of Site Inchagre Work Includs Grouting Stracture And Making Plinth As Per Norms All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. , Dismantling Of Existing Electrical Equipment At Site, Including Proper Handling To Avoid Damage, And Safe Carriage/Transportation From The Work Site To The Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends, Covering All Leads Over Kachcha And Pucca Roads, Complete With All Labour, Tools & Plants, And Necessary Precautions, As Per The Directions Of The Site Incharge. All Labour Will Be Provided By Contractor In All Respects.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
12.
Educational and Research Institute #11268291 AOC
Tender For Renovation Of Electrical Installations Of Ppa Hospital; 1 Supply of 36 watt (2 ft. x 2 ft.) recess mounted LED light complete with inbuilt LED lamp. 2 Supply of 18 watt (1 ft. x 1 ft.) surface mounted LED light complete with inbuilt LED lamp. 3 Supply of 36 watt LED batten light with inbuilt LED lamp. 4 Supply of 1400 mm sweep BLDC ceiling fan as per Scope of work. 5 Supply of 300 mm sweep exhaust fan. 6 Supply of 250 Amp. Outdoor type Feeder Pillar having 01 no. 250 Amp. 4-Pole MCCB as incoming and 03 nos. of 125 Amp.4-Pole MCCB & 02 nos. of 63 Amp. 4-Pole MCCB with 04 nos. of 250 Amp. copper bus bars as outgoing. 7 Supply of 125 Amp. Wall mounted Distribution Board having 01 no. of 125 Amp. 4-Pole MCCB as incoming and 01 no. of 63 Amp. 4-Pole MCCB, 8 nos. of 32 Amp. DP MCB with 04 nos. of 125 Amp. copper bus bars as outgoing. 8 Supply of 4 C x 95 sq. mm, 1.1 KV grade, G.I armoured,XLPE insulated stranded aluminum conductor cable as per scope of work. 9 Supply of 4C x 25 sq.mm PVC insulated copper flexible cable. 10 Supply of 4C x 16 sq.mm PVC insulated copper flexible cable. 11 Supply & fixing of 16-way double door type MCB Box having 1 no. of 125 Amp. 4-pole MCB, 8 nos. of 32 Amp. SP MCB & 4 nos. of 20 Amp. SP MCB. 12 Supply & fixing of 12-way double door type MCB Box having 1 no. of 63 Amp. 4-pole MCB & 8 nos. of 20 Amp. SP MCB. 13 Supply of 90 watt LED streetlight fitting having inbuilt LED lamp. 14 Supply of Refrigerant copper pipe with insulation & rapping tape for 2 TR / 1.5 TR Air Conditioner. 15 Supply of copper Communication Cable between ODU & IDU. 16 Supply of PVC drain pipe 17 Supply of outdoor stand for Air Conditioner. 18 Wiring to light point with 6/10 Amp. modular switch alongwith modular board & plate as per scope of work. 19 Wiring to fan point (Ceiling fan / Exhaust Fan) with 6/10 Amp. modular switch alongwith modular board & plate (wall mounted / exhaust fan) as per scope of work. 20 Wiring to 6/10 Amp.modular socketalong with modular board & plate as per scope of work. 21 Wiring to 16/20 Amp. modular type plug point with provision of switch & socketalongwith modular board & plate as per scope of work. 22 Wiring to 90 watt LED Streetlight point as per scope of work. 23 Wiring to A.C Point with 25 Amp./32 Amp. modular starter as per scope of work. 24 Laying & concealing of 4 C X 25 sq. mm copper flexible cable from the nearest feeder pillar to BDB point by using suitable size of polethene / HDPE pipe inside brick wall. 25 Laying & concealing of 4 C X 16 sq. mm copper flexible cable from the nearest wall mounted distribution board to BDB point by using suitable size of polethene / HDPE pipe inside brick wall. 26 Fixing of light fittings. 27 Fixing of ceiling fan. 28 Fixing of exhaust fan. 29 Fixing of 90 watt LED streetlight fitting with supply of G. I bend pipe. 30 Shifting & restallation of outdoor units of Air Conditioners by using outdoor stand. 31 Installation of line Lightning Arrestor for protection of Hospital Building with supply of 50 mm x 6 mm G.I flat & other materials as required. 32 Supply and laying of 1 sq. mm PVC insulated single core flexible copper wire for running earth to BDB points. 33 Preparation of chemical eartthing with 18 ft. x 50 mm dia GI pipeincluding supply of all required materials. 34 Note:We hereby confirm that the above quoted price is inclusive of all taxes, duties, cess etc. and all other incidentals like transport, insurance etc. excluding GST and a firm landing price at Paradip Port Authority.
Contract Date: Jun 11, 2026 Contract Value : 31.05 Lakh
Government Departments No of Bidders 7
13.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
14.
Rural Development #11250007 AOC
Tender for Providing, Erecting And Supplying Various Different Electric Material For 1 Year @Gr Anchayat Kadamwakwasti , Electric Material This Rate Please Mentioned Include Gst Invoice Shall Be Prepared With Gst Tax Whatever Applicable On Material Rate Are Mentione With Gst , Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Angle Iron 50X50x6 Mm And 550 Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh -Pl/Bkt , Making Cement Concrete Foundation Including Excavation (60 X 60 X 150) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, (45 X 45 X 45) Cm /45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (Above 6 M To 9 M Poles) , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 6 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 8 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm. Dia With 4.5 X 4.5 X 3.65 Mm Thickness ( 5 + 2 + 2M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 147 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia With 4.5 X 4.5 X 3.65 Mm. Thickness (5 + 2.5 + 2.5 M) Length Respectively And Total 10 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 160 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia. With 4.5 X4.5 X3.65 Mm Thickness (5.60 + 2.7 + 2.7 M) Length Total 11 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 175 Kg.) As Per Specification No. . Oh-Pl/Stp , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting On Tubular Welded Pole With 40 Mm. Dia 1.0 M Long B Grade G.I. Pipe Along With Pole Cap Of 125Mm Dia 600 Mm Long Duly Welded As Per Specification No. Fg-Bkt/Bpc , Supplying, Erecting & Marking Dpmcb 40A To 63A, B- Series (For Lighting) In Provided Distribution Board As Per Specification No. Swswr/Mcb , Supplying And Erecting Insulated D.P. Switch Surface Type/Flush Type 32A 240Vwith Indicator Lamp & Fuse , Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching On & Switching Off Street Light As Per Daily Sunset And Sunrise Respectively , Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm (30 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm (50 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting Suitable For Above 40W To 48W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No Bajaj. Fgodf/Fls2. , Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete As Per Specification Bajaj No Fg Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting Suitable For Above 70W- 75 Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls2 , Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting 100W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 120 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 150 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg Odf/Fls-2 , 2-5-17 Supplying And Erecting Led Flood Light Fitting Of 150W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification Jno. Fg-Bkt/Bpc(2-9-2) , Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘B Class G.I. Pipe 1.2 M In Total Length Complete As Per Specification No. Fg-Bkt/Wb(2-9-3) , Supplying & Laying Pvc Armoured Cable 4Core 6Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 10 Sq Mm 7-1-15 , Supplying & Laying Pvc Armoured Cable 2Core 10 Sq Mm , Supplying & Laying Pvc Armoured Cable 2Core 6 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 16 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 25 Sq Mm , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 70 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 95 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 120 Sq. Mm. Aluminium Conductor With Continuous , Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series (For Lighting) , Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries (For Lighting) , Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete , Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete... , Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block/Provided Box, With Necessary Materials. , Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole , Supplying & Erecting Mains With 2X4 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No: Gma/Bw , Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 , Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , 25 Amp, 32 annual periodical maintenance Three Phase L/T Contactor , Insulation Tape , Water Proof Tape , Cable Joint Kit Upto 25 Sq. Mm Cable , Cable Joint Kit Upto 35Sq. Mm To 95 Sq Mm Cable , Cable Joint Kit Upto 120Sq. Mm To 185 Sq Mm Cable , Cement Street Light Pole Clamp With Nut Bolt , M.S. Street Light Pole Clamp With Nut Bolt , Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes(Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Servicing And Primary Maintenance For Street Light Pole. , Light Poles Painting In Silver Colour , 26W Led Light To 100W Led Light Repairing , Old Pole Shifting, Rework And Foundation Work Per Pole Etc. , Supply &Fixing Of Shakle Hardware With Nut Bolt , Supply And Installation Of Mini Feeder Pillar With Stand , Reinforced Cement Concrete Road Cheasling Charges With Tractor Breaker (1 Hours) , Tree Triming For Overhead Line , Supplying & Erecting Street Light Control Panel Outdoor Type, For Single Phase 2 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 2 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete. , Supplying & Erecting Street Light Control Panel Outdoor Type, For Three Phase 4 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 4 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete , Servicing And Primary Maintenance Of Solar Light Pole 1 Visit In Month Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection, Timer Working Condition And Panel Cleaning , Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 9 W Led Fitting, 12V 18Ah Maintenance Free Lithium Battery, Min. 40 Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esd-Sol-Stl ( With 5 Years Warrantee ) , 4-3-13 Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 12W X 2 Nos. Led Fittings, 12V Min. 100Ah Maintenance Free Lithium Battery, Min. 120Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esdsol-Stl , Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. , Providing & Erecting 7 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No.Oh-Pl/Opl. , Providing & Erecting 9 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 155 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 10 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 175 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 11 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 210 Mm A/F, Top 90 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For Highmast Of The Same Manufacturer With 63A Tpn Mcb Incomer, Single Dial Timer Switch, 45A Tp Contactor For Automatic Switching Of Luminaries, 2 Nos 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Erected In Min. 14 Swg Crca Sheet Box Powder Coated With Supporting Angles, Self-Lock, Gasket And Slanting Top Erected With cement concrete Foundation Complete , Supplying And Erecting 12.5 M (Clear Height) High Mast (Top 150Mm, Bottom- 360Mm) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 6 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Hm (Excluding Luminaries ). , Making Cement Concrete Foundation Including Excavation (60 X 60) Cm X Deep 1/6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, 45 Cm X 45 Cm X 45 Cm /45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (For Above 9 M Poles) , Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Fpmccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation As Per Specification No. Sw-Swr/Mfp , Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14/16 Swg Sheet, Outdoor Type, Single Phase, 240 V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Spn Mcb 63 A Auto/Manual Selector Switch,On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / cement concrete Foundation Complete. , Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials As Per Specification No. Ea-Ep , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 600Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 900 /1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. , 36 Watt Pcb , 36 Watt Driver , 50-60 Watt Pcb , 50-60 Watt Driver , 70 Watt Pcb , 70 Watt Driver , Highmast Repairing 100-150 Watt , Service Wire 4 Sq.Mm Isi Mark 2 Core , Service Wire 6 Sq.Mm Isi Mark 2 Core , Service Wire 10 Sq.Mm Isi Mark 2 Core , Frp Box Of Size 300 X200 X125 Mm 2.7Mm Thickness , 12W Led Bulb , 14W Led Bulb , 18W Led Bulb , 100 W Bulb , 200 W Bulb , 35 annual periodical maintenance Kitkat Fuse , 63 annual periodical maintenance Kitkat Fuse , Servie Reel Pvc , Retrofit T8 Led 18/20 Tube Light , Lamp Holder China Clay , Lamp Holder (Pendent) , 5Am Shocket Armor , 5Am Sawich Armor , Miter Box Singal Phase Pvc 300X150x420 , Miter Box 3Phase Pvc 540X600x200 , Miter Box Coted , 8M Sarfes Box & Pleat , Rsj Pole 9 Mtr , V Cross Arm 22 Kv , Cut Pont Set 22 Kv , Pin Insulater22 Kv , Disc Insulater 22 Kv , Nut Bolt , Conductor 55 Sq Mm Aac , Ht Stay Set , Lt Stay Set , Stay Wire , Gi Wire 8 Swg , Pole Errection , Conductor Errection , V Cros Fixing , Cutpoint Fixing , Mcb Box Metal 3Way , Supply Of Tiranga Pole As Per Sepcifucation 139.7Mm Od Pipe - 3Mtr 114.3Mm Od Pipe 1Mtr - 03 Nos 88.9Mm- Od Pipe - 2 Mtr Total 8 Mtr Pole , Day &Night Motin Sensor Auto On/Off Light Electronics(With Drayvar) , 9 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 6 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 6 Nos. E) Solar Panel Should Be Of 330 Watt --- 6 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , 6 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 4 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 4 Nos. E) Solar Panel Should Be Of 330 Watt --- 4 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , Gst Charges
Contract Date: Jun 08, 2026 Contract Value : 14.78 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
16.
Defence #11206901 AOC
Tender For Provision Of Work Services For Sdr Facility In Abr Lab At 9Brd Afs Pune Under Ge Af Lohegaon - Taking down the existing surface batten type point wiring of aluminium/Copper for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. 2 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 3 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board )ISI Marked (IS:14772) for housing switches / sockets all a specified and directed 4 (a) One Fan point/ light point controlled by one switch. 5 (b) One 3 pin socket 5 A on same board. 6 (c) One 3 pin socket 5 A on independent board. 7 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board)ISI marked (IS 14782) for housingone 15 A Switch / socketsall a specified and directed 8 M/L for sub main wiring with two runs of single core 4.0 Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 4 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cablefor continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified.(Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length) 9 M/L for sub main wiring with two runs of single core 6.0Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length ) 10 Supply and fix switch piano flush type 5 Amp one way, ISI Marked 11 Supply and fix Socket out let 2in 1, 5 pin 5 Amp ISI Marked 12 Supply and fix switch socket combination 5 / 16 A, 5 in 1, flush type,ISI Marked 13 S/F Fan Regulator electronic step type 100 W,ISI Marked complete as directed 14 Supply and fix ceiling rose surface type bakelite / PVCthree terminal 65 x 50mm. ISI Marked 15 Taking down existing VTPN DB grouted in wall and S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 16 Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge. 17 Supply and fix MCB SPN B Curve 240 V, 32 Amps. complete all as directed at site. 18 Supply and fix MCB SP B Curve 240 V ,6 to 32 Amps complete all as directed at site. 19 M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plateNo. 3 of SSR Part I of 1991 & testing complete including 15mm dialight grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GIwatering pipe etc. 20 Supply and fixing in replacement of double pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed 21 S&F of CEE Panel mounted receptacles 16 A, 3 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 22 S&F of CEE Panel mounted receptacles 16 A, 5 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 23 S&F of CEE plug 16 A, 3 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 24 S&F of CEE plug 16 A, 5 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 25 S&F of Sub main wiringwith 4 X 6 sqmm single core cable FRLSH PVCinsulated unsheathed of copper multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length). 26 S&F of Sub main wiringwith 4 X 10 sqmm single core cable PVCinsulated unsheathed of copper FRLSH multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length). 27 Taking down carefuly copper strip of Size upto 32x6mm including pocelain/epoxy insulator, storing in safe custody for reuse and refixing the taken down copper strip as directed at site including supply and Fix of new epoxy insulator at a gap of 1 meter and brazing of copper strip with double nut and bolt with overlap of 3 cm complete all as directed by Engr-In-Charge. 28 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed. 29 Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site. 30 Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site. 31 M&L for making hole in Brick masonary / Stone masonary wall of any thickness and height of round shape and suitable for exhaust fan of 380mm dia and making good disturbed wall and painting distubed area as original complete all as directed. 32 Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louver complete all as specified and directed. 33 1. Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2TR having dual rotor inverter compressor, 100% copper IDU and ODU, installation kit with extra copper piping, connection electric cord, drain water pipe as per site requirement and incl MS Stand for outdoor unit fixng and core cutting in stone masonary wall if required for passing of refrigerant piping and cables etc and making good disturbed surfaces matching to existingcomplete all as specified and directed by Engr-In-Charge 34 Supply and fixing of voltage stabilizer for automatic operationsingle phase naturally air cooled indoor typefor input variationbetween 170V to 280V with outputVoltage 230v with accuracy +/-2.5% and of capacity 5 KVA completeall as directed. 35 Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. 36 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 300 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 37 S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 38 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 35 Sqmm 3.5 Core laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix on wall etc all as specified and directed. 39 Supply install, test and commissioning of Powder coated LTpanel cubical Indoor type floor standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomerand outgoing feeders .The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhave bottom frame & dimension as required for panel & stand shall be made out of equal angle iron of size 50mm x 50mm x 6mm height 600mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 tank process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including provision of heat shrink sleeve on each cable core within panel, lugs, nut bolts, washers etc complete all as specified and 40 a) Copper bus bar 500 Amps for 4 pole-01 SETb) MCCB FP 320 Amps415 Volt 50 KA,Ics =100% Icu WITH thermal and magnetic setting type - 1 Nosc) MCCB FP 100 Amps - 415 Volt 16 KA,Ics =100% Icu- 5 Nos f) RYB Indicators - 1 Set and g)Digital 3 Phase Amp Meter and Voltmeter with selector switch - 1 SetNote - (i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication. 41 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 25 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 42 Supply and fix Voltage stablizer for automatic operation, three phase , naturally oil cooled, inddoor type anddesigned for input variation between 300V to 480 V with accuracy + 2.5 % , IP55 Protection, 50 Hz, Unbalance type, copper wounded, matallic body duly powder coated, liftinghooks, digital display, relay controlled for smooth and silent operation with first filling of transformer oil upto specified level , with zero distortion waveform, sesitivity +/- 1%, overall Efficiency more than 95 % digital multifunction meterand speed of correction 8 volts per second and of capacity 30 KVA complete all as specified and directedNote: (a) Stablizer shall be free from hunting during automatic operation and No load losses shall not be more than 5% of rated output current.(b) Protection: (i) Overload short circuit protection at input end by MCCB 4 pole of suitable size as per recommendation of OEM - 01 Nos (ii) High / low voltage cutoff(iii) By pass arrangement - providing 01 No 4 pole on load changeover switch of suitable rating (iv) single phase sequence change protection.(c) Acceptance Test :- Testing of servo voltage stabilizer should be carried out as per BIS 9815 (Part-I) in OEM factory in the presence of rep of Accepting Officer and contractor/his rep. Contractor shall give 45 days in advance intimation with respect of date of testing. The following testing shall be carried out:(i) Physical Examination (ii) Insulation resistance (iii) High voltage test (iv) Leakage current test (v) Output voltage (vi) No load current (vii) Measurement of No load loss induced voltage testNote : Before make and specification approval type test report of OEM as per BIS 9815 Part - I should be produced by contractor for the specified capacity / next higher capacity of any voltage range from Govt Lab / NABL accredited lab. 43 Supply, installation,Boring, erection, testing and commissioningof Copper bonded(150 micron) MS solid rod electrode of dia 17.2 mm and 6 mtr long with high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Earthing Electrode shall bemade by embedding copper bonded MS Rod electrode in 100mm dia macronite conductive concrete made by mixing high purity conductive granularmixed with cement in the ratio2:1 (2 part of high purity electriclly conductive granular and 1 part cement and one litre of water per kg of mix ). The earthing electrode shall be augured inbore hole of dia not less than 100mm and6 Mtr depth. The conductive material shall confirm to BIS: 3043-2018. The rod shall be embedded in conductive concrete at factory with concrete having resistivity 0.040 Ohm-m. The top edge of the electrode shall comprise of plate provided with 04 holes for connections of the earthing strip,including brass nut bolts for connections of the strip the copper strip shall be duly brazed/welded with connection terminal of earthing rod, including FRP square chamber cover 300mm x 300mm x 250mm with top cover complete all as specified.All the material such as copperbonded MS rod and concrete mix shall be Ph nuetral, chemicaly inert and non corrosive complete all as specified and directed by Engr-In-Charge.i) The contractor shall submit type test report issued by the CPRI for high purity, electrically conductive earthings , confirms to rated short time withstand current20 KA per sec. ii) The factory made electrode shall be tested at factory and test report shall be submitted.iii) Factory testing of individual earthing shall be carried out in presence of rep of accepting officer and report shall be submitted.iv) The contractor shall obtain make approval for high purity electrically conductive granular duly by submitting certificates conforming to resistivity is 0.001 ohms by granular manufacturer.v) On installation of earthings at site, 04 to 05 Nos earthings shall be connected in grid to achieve less then 1 ohm resistance of grid, If desired resistance is not achived the contractor shall redo the same without any extra cost. vi) The contractor shall submit certificate issued by OEM of earthing electrode starting that The desired maintenance free earthing resistance less than 1 ohm. The year will be maintained for not less than 25 years. 44 M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.Note:-(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 45 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified.Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 46 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal block cover box made out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer. 47 S & F copper earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc.and connecting with earthing test point oras required complete all as directed. Note: Earth work required shall be deemed to be included in quoted rate, nothing extra shall be paid on this account. 48 Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc. 49 Soft/loose soil 50 Hard/dense soil 51 Soft/disintegrated rock 52 Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil. 53 Removing the surplus soil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level. 54 M&L for Cutting the existing road precisely for laying of cable crossing pipe and making good the distubed surface of road as per original after laying of pipe and removal of debries complete all as directed.Note: The cost of making good is deemed to beincluded in quoted rate. 55 Supply and fixof MCCB FP 63 AmpsFixed type with breaking capacity16 KA with Sheet metal enclosure of 2 mm thick CRCA sheet single door with provision opening for incomming and outgoing cable/ submain including connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
Contract Date: Feb 04, 2026 Contract Value : 35.23 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
Contract Date: Jun 05, 2026 Contract Value : 10.74 Lakh
Government Departments No of Bidders 6
Maharashtra View Result →
18.
Defence #11167640 AOC
Tender For Provision Of Single Men Barracks Including Cook House For Agniveers At Brc, Danapur.; 1 SCHEDULE A Part-I (Building/Structures) (To be quoted by the tenderer) 2 Item No 01 A : Design and construction of 180 ORs SM BarrackComplete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 3 Item No 01 B: Design and construction of Dinning Hall Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 4 Item No 01C : Design and construction of Cook House Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 5 Sch A Part-II (Internal Electrification)Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III (External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule A Part-III against the lump sum price inserted by the MES. 7 Sch A Part-IV(External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 8 Sch A Part-V(Road, Path Curvert)Lump sum price worked out by the contractor for (Road, Path Curvert)as listed in Schedule A Part-V against the lump sum price inserted by the MES. 9 Sch A Part-VI (Air Conditioning)Lump sum price worked out by the contractor for (Air Conditioning) as listed in Schedule A Part-VI against the lump sum price inserted by the MES. 10 Sch A Part-VII(Refrigeration System)Lump sum price worked out by the contractor for (Refrigeration System) as listed in Schedule A Part-VII against the lump sum price inserted by the MES. 11 Sch A Part-VIII((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM)Lump sum price worked out by the contractor for ((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM) as listed in Schedule A Part-VIII against the lump sum price inserted by the MES. 12 Sch A Part-IX(Demolition of Bld (B/R) Lump sum price worked out by the contractor for (Demolition of Bld (B/R)as listed in Schedule A Part-IX against the lump sum priceinserted by the MES. 13 Sch A Part-X(Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal)as listed in Schedule A Part-X against the lump sum priceinserted by the MES. 14 Sch A Part-XI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule A Part-XI against the lump sum price inserted by the MES. 15 Sch A Part-XII(Site Clearance) Lump sum price worked out by the contractor for (Site Clearance)as listed in Schedule A Part-XII against the lump sum priceinserted by the MES. 16 Note for Srl No 2 to 15The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 14by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 17 Schedule A Part-XIII (Miscellaneous items of works) 18 INTERNALELECTRIFICATION 19 Item No 02 : Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade(MMS/HMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. 20 flush mountingMS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing of andincludingwhite/Silver/Dark bronzecolour modular blankingplate as per number of switch modules flush mountedfor fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colourmodular plate cover of required modules andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directedfor the following:- 21 (a) One light point controlled by one switch. 22 (b) Onefan point controlled by one switch and oneregulator. 23 (c) Oneexhaust fan point controlled by one switch . 24 (d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . 25 (e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . 26 (f) One bell/buzzer point controlled by one bell push. 27 (g) One light point controlled by two 2 way switches. 28 Item No 02 : All as per item No.1(d) & (e) above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- 29 (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board. 30 (b) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board. 31 Item No 03 :All as per item No.1 (d) above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. 32 Item No 04 : Supply & fixingand sheet metal enclosurewith acrylic door type, double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection complete all as specified and as directed. Note for item No.22 to 32- MCCB/MCB DBs and MCBs/MCCBs both are used same make only 33 Item No 05: Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. 34 External Electric supply 35 Item No 06 :Supply, installation, testing and commissioning of step down copper wound transformer of capacity 315 KVA (Energy Efficient LEVEL 3 ), outdoor type, plinth platform of min size 2.4 x 2.4 x 1.5 Mtr (Solid PCC Block) complete with standard fittingts and accesswories, HT 11 KV 3 phase, Lt 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 (Part-I)-2014 (latest edition) with amendment no. 1,2,3 & 4 (Level 3). oil cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:- 36 a) three numbers porcelain bushing HT, 11KV with Brass bushing Rod, Nuts, bolts and washers etc inside cable end box b) One cable box LT side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG cables c) Oil conservator with filter type drain valve and oil level guage 37 d) Dehydrating breather with fast feel of dehydrating agent e) Explosion Vents f) thermometer pocket on tank cover g) Rating Plate on terminal marking plate h) Earthing arrangement i) Oiil drain filter valve j) Oil Drain Valvek) Lifting Hook 38 l) Oil conservator with filling hole and capm) Air release valve plugn) Four plate solid cast steel detachable rollerso) Buchholz relay p) Earth Bushing for neutral Outside the cable box for neutralq) Suitable size of channel on foundation for fixing the transformer with jint and stopper(r) Plateform for mounting of transformer made up of PCC 1:2:4, 20 mm graded stoen aggregate, solid block and making all faces fare using extra cement as per manufacturer design of required length, width and hight in and including providing of 02 nos ISMC 100 chanel embe3dded in PCC of wuitable length as directed at site by the engr in charge in and including earth work complete. 39 Note: (i) Anything missed out above but technically required for proper operation of transformer is deemed to be included in the quoted rate. 40 Item No 07 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. 41 Item No 08 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3½ core complete all as specified and as directed. 42 Item No 09 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3½ core complete all as specified and as directed. 43 Item No 10 : Supply and fix cable jointing kit for 1.1 KV grade cable for straight through/ end terminal joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 sqmm,Indoor/Outdoor type complete all as specified and as directed. 44 Item No 11 : Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved ,feeder piller box of made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical legs frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. 45 Incoming (a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity, rating 400 Amps including all fixing accessories with both ends spreader links-01 No. (b)Digital voltmeter of range (0-500) volts, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(c)Digital Ammeter of range (0-250) Amps, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three). 46 Outgoing(a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 250 Amps including all fixing accessories with both ends spreader links-01 No. 47 (b)MCB,4 pole, 415V, C series rating 200Amp Amps including all fixing accessories with both ends spreader links-02 No. (01 + 01 spare) 48 (c ) Copper strip busbar of 600 Amps current carrying capacity with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos. 49 (d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. 50 Item No 12 :M&L for Shifting of existing VCB from existing location near pump house No:2 over head tank to proposed building approx 300 Mtr with the help of crane including necessary T&P including Servicing, comprising of overhauling and refixing the same after repairs: (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection.(b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required. 51 (c) Servicing/Inspecting/checking ofcircuit spoutand cicuit spout connections for RYB phases and replacement of spares if required.(d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f)Servicing/Inspecting/checking ofsecondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required. 52 (g)Checking, setting and adjustment of lowering and raising operation of the breaker trolley. (h)Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. (j) The inspection of HT switch gear shall involve:-(i) Inspection of truck & hoist assembly.(ii) Inspection of tank assembly & barriers.(iii) Inspection of assembly & components of solenoid assembly.(iv) Inspection of assembly & components of dependent mechanism.(v)Inspection of assembly & components of spring box mechanism.(vi)Inspection of motor mechanism spring charge assembly (vii)Inspection of assembly of trip unit & related components.Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound and any damaged parts etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. 53 Item No 13 : M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. 54 Item No 14 : M&L Costruction of a 18 sqm room with a height of 3.5 mtrs, designed to house a vaccum circuit breaker (VCB). The costruction will include foundation work, walls, roofing , flooring, plastering and miscellaneous items like windows and doors. complete all as specified and as directed. 55 External Water Supply 56 Item No 15 : M & L for Construction of brick masonry valves pits , of the following internal dimension complete with 3015mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC wok complete. 57 (a) 900mm x 900mm x 900mm 58 (b) 600mm x 600mm x 600mm 59 Item No 16 : Refixing MS/ GI/ CI DI pipe any type and connections in new or old position including cleaning internally and externally, any grade / make (in trenches) including all type of new fittings i.e. sockets, Tee, union, elbow etc complete all as specified and as directed. 60 (a)100 mm dia 61 (b) 150 mm dia 62 Item No 17 : Supply and fixing in replacement ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for distrubed surfaces of roads, pathways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, excavation of pipe line, connections etc complete all as specified and as directed. (a) 150 mm dia 63 Refrigeration System 64 Item No 18 : Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star rated complete all as specified and directed. 65 Item No 19 :Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA. 66 Water cooler 67 Item No 20 : Supply, installation and Commissioning water cooler, Electric driven,(single phase 230 volts) having approx storage capacity of 120 Litres and nominal cooling capacity of 60 Litres per hour complete all as specified. 68 Item No 21 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified. 69 Air Conditioning 70 Item No 22 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified. 71 Hot Water Supply 72 Item No 23 : Supply and fix Water heater storage type, electric,capacity 50 litres.BEE 5 star rated 73 Item No 24 : Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed. 74 Dessert Cooler 75 Item No 25 : Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Steel body type complete all as specified and directed. 76 Electric Chimney 77 Item No 26 : Supply, installation testing and commissioning commercial kitchen chimney stainless steel body with filter size 96 X 30 including 1 HP exhust fan, Air outlet duck of chimney G.P sheet 0.50 mm thick of size 22 X 22 X 15 ft long complete all as specified and directed. 78 FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM 79 Item No 27 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138. 80 Item No 28 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class A, B, C Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B 81 Item No 29 : Supply only of Fire bucket iron body red colour 10 L capacity for dry sand stored type ISI MarkedIS : 2546 :2006, complete all as specified and as directed. 82 Item No 30 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B 83 Sewage Disposal 84 Item No 31 : M&L for DWCPE (SN8) pipes 180 OD/163 ID, laid and jointed complete complete all as specified and directed for the following internal dia of pipes. 85 Item No 32 : Construction of Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, Base slab, Baffle walls and roof slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users conventional type. 86 Item No 33 : Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 3.0 M effective depth. 87 SCHEDULE A(Schedule of credit)Schedule of Credite Rs 50001.00 (Minus) inserted by the MES.(Note : Credit amount shall be deducted manually to arrive net bid amount)
Contract Date: Jun 27, 2026 Contract Value : 10.28 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
19.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
20.
Defence #11149786 AOC
Tender For Provision Of Deficient Smqs At Najafgarh Under Ge Af Tughlakabad - SCH A PART XI (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule A Part-II. 11 INTERNAL WATER SUPPLY 12 Supply and fixing Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia fixing in pipe with 1.25 meter long flexible tube and ABS wall hook including making connection and fixed to 15mm bore completeall as specified and directed. 13 Supply and fixingangle valve of cast coper alloy chromium plated fancy type screwed down high pressure with crutchor butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore (concealed) complete all as specified and directed. 14 Supply and fixing 15mm dia Two Way Bib taps, fancy type,,cast copper alloy chromium plated with crutch or butterfly handle, screwed down for CPVC pipe or for brass ferrule and fixed complete all as specified and as directed. 15 Supply and fixingBrass CP Mixer for mixing hot & cold water screwed down for 15 mm dia CPVC Pipe and fixed all as specified and as directed. 16 INTERNAL ELECTRIFICATION 17 Supply and fixing LED Lamp 9 watt 220 volts AC of suitable size complete all as specified and as directed. 18 Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 19 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 20 Supply and Fixing LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and as directed. 21 Supply and fixingLED Building Securitylight fitting 25 watt complete all as specified and directed by Engr -in- charge. 22 Supply and fixingGI light gradepipe 1.5m long bend to 45 degree andof diameter 25 mm suitable to building security light power cord pipediameter with necessary clamps of for fixing building security light all as specified and directed including making hole to wall if necessary (For Bldg Security Light) complete all as specified and as directed. 23 Supply and fixing MCCB 63 Amps 4P 25 KA 415 Volt Make Indoasian Cat No 830020 includingMCCB Enclosure for 63 Amp MCCB Make Indoasian Cat No 811985 fixed on wooden board of appropriate size for mounting of enclosure complete all as specified and as directed.NOTE:-Rate inclusive of Fixing of cable including lugging complete (For06 Qtrs) 24 Supply and Fixing ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed. 25 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm (for Toilets) complete all as specified and as directed. 26 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m (for Kitchen) complete all as specified and as directed. 27 Supply and Fixing electric water heater, storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed. 28 Supply and fixing Smart RF/CellularSingle Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 315 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Radio Frequency communication facilitywith self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry including Polycarbonate Meter Box of minimum suitable size for 1 Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . Including Taking down of existing meter and deposit to MES store yard for safe custody all as specified and as directed (For06 Qtrs)Note:- Contractor has to ensure integration and maintainance of the above 06 nos of meters withthe existing Advance Metering infrastructure (AMI) of smart meters of different makeswithout any additional infrastructure and cost implication. 29 EXTERNAL WATER SUPPLY 30 Material and Labour for valve chamber of internal size 750x750x750 mm comprising of 50 mm thick PCC 1:5:10 type E2 foundation, 200 mm thick brick wall in CM 1:6 ,15 mm thick plastring in CM 1:4 internally and externally up to 50 mm below GL, 100 mm thick PCC 1:3:6 type B1 as in coping, 3 mm thick MS sheet cover with suitable hinges and locking arrangements, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed. 31 EXTERNAL ELECTRIC SUPPLY 32 Supply and fixing of LED security/street light fitting 1x70 W LED 5700K energy saving and environmental friendly long life versatile pressure die cast aluminium hosing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LEDs as light source and electronic driver suitable for pole dia 40mm including 45mm dia light grade tube bracket, bent to shape, 1.8 mtr lenght with two Nos clamp of size 50mmx6mm with nuts,bolts,washers etc. including connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on walls/pole complete all as specified and as directed. 33 Supply and fixingof LT Panel board outdoor type, double door, fabricated made of MS/CRCA sheet 3.15 mmm thick with MS angle frame of size 50x50x6 mm with locking arrangements cubical type feeder pillar box with 04 Nos legs including necessary PCC work with suitable size of PCC 1:3:6 including necessary insulators and 04 Nos of copper bus bar of size 30 mm x 5 mm capacity of 600 Amp with Air circuit breaker, provision of inlet and outlet cable glands and earth connection lead etc complete and connection of all incoming and outgoing cable using aluminium terminal sockets/lugs duly crimpled and necessary two coats of paint with approved make and colour and grade of first quality synthetic enamel paint over a coat of red oxide primer including necessary preparation of surfaces and the panel should be dust and vermin proof factory fabricated , CPRI approved totally enclosed free standing /wall mounting type suitable for 415 vots, 50 HZ 3 phase 4 wire system complete in all respect and confirming to latest relevant of ISI specifications including necessary connections, inter connections with copper conductor cable of required size including MS angle frame of size 50x50x6 mm structure at bottom and with including the following accessories.:- 34 INCOMING :- (i) MCCB,AC 415 Volts, adjustible thermal release, 4 pole current rating 63 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 01 No.(ii) 4 strip copper bus bar of size 30 x 5 mm with specific colour (R,Y,B) insulation = 01 set(iii) Metering panel comprising,voltmeter and ammeter, digital type with selector switches CTs, control fused and indicating lamps. OUTGOING : (i) MCCB,AC 415 Volts, adjustible thermal release, 3 pole current rating 32 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 02 Nos for (01 No Building & 01 No. spare) (ii)MCB SPN 32 amp 215 volts C curve (for street light) = 01 No.(iii) Digital Voltmeter 0-500 volts - 01 No.(iv) Digital Ammeter 04-400 Amps - 01 No. (v) Indicator lamps Red, Yellow & Blue.(vi) Complete wiring of Panel Board.(vii) CT ratio 400/5 Amps 35 Supply and fixing SMC junction box, pole mounted, 100% weather proof, fire retardant , complete with side hinged door of size 250x200x105 mm , made out of engineering plastic including 3 phase 4 wire aluminium bus bar of capacity 60 amp of required size complete with bus bar insulator fibre/ porcelain and one no single pole MCB SPN 6 Amp . B Curve and box fixed on pole with clamps made out from MS flat iron of size 25x5 mm with nute and bolts complete all as specified and as directed. 36 Material and Labour for sub main wiring with 2 run of 1.5 sqmm multistand copper conductor , PVC insulated, 1100 volts grade in and including PVC condut with 1.5 sqmm PVC insulated multistrand copper earth continuity conductor including lugs of suitable size from light fitting connector to looping box on pole complete all as specifed and directed. 37 AREA DRAINAGE 38 Material and labour for pre-cast perforated RCC drain cover with frame ( rectangular or square) the area of each cover should not be more than 0.5 square meter and thickness of 60 mm each with holes, manufactured with M-30 grade of concrete by vibro compacting process using accurately designed moulds and suitably reinforced to enable the covers to take load as specified i.e M-20 MT for heavy duty (When tested as per IS -12592) complete all as specified and as directed. 39 SEWAGE DISPOSAL 40 Supply, laying in trenches and jointing of 200 mm dia bore double wall corrugated polyethelene (HDPE) pipe of stiffness class designation SN8 including all necessary jointing material and fittings such as couplers, connectors,bends, elbows ,Tees and end caps etc complete all as specified and as directed
Contract Date: May 22, 2026 Contract Value : 1.91 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
21.
Power #11110319 Technical Bid
Tender for Rate Contract For Procurement Of Material That May Be Required During The Emergencies For The Year 2026-27 In Respect Of Ed-3Rd , Supply Of , 50 Mm² Ab (Ht) Cable (3X50 + 1X70 Mm²) Xlpe(11 Kv, 3C + Earth) , 70 Mm² Ab (Ht) Cable (3 X 70 + 95 Mm²) Xlpe(11 Kv, 3C + Earth) , 120 Mm² Ab (Ht) Cable (3X120 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 150 Mm² Ab (Ht) Cable (3X150 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 185 Mm² Ab (Ht) Cable (3X185 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Upto 50- 95 Sqmm ( 3 Core) , Heat Shrinkable Outdoor Cable Termination Kit Above 120 To 185 Sqmm ( 3 Core) , Mid Span Straight Through Jointing Kit For 11 Kv Abc 120 -185 Sqmm , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 95 Mm² Ab (Lt) Cable ( 3 X 95 + 1 X 16 + 1 X 70 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 16 + 1 X 70 Mm²) Xlpe (1.1Kv, 3+1 C, Al) , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 95-150 Sqmm , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 35-70 Sqmm , 70 Mm² Single-Core Cable, 1.1Kv Grade, Xlpe Un-Armoured Frls Type , 95Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 120 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 150 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 185 Mm² Cable, 1.1Kv Grade, Xlpe Un Armoured Frls Type , 240 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 300 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 400 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 500 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 630Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 10 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 10 Mm² Cable (4C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (4C),1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 25 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , 35 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , Single Core 1 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 1.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 2.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 4 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 6 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , 11 Kv, 3- Core Xlpe 35 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 50 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 70 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 120 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 150 Mm² Round Wire Armoured, Frls Cable , 11Kv, Three Core 185 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11 Kv, 3- Core Xlpe 240 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 400 Mm² Round Wire Armoured, Frls Cable , 11 Kv End Termination For 3C 120- 185 Mm² , 11 Kv End Termination For 3C 240 To 400 Mm² , 11 Kv Straight Through Jointing Kit Upto 50-95 Mm² , 11 Kv Straight Through Jointing Kit Upto 120-185 Mm² , 11 Kv Straight Through Jointing Kit Upto 240-300 Mm² , 11 Kv Straight Through Jointing Kit Upto 400 Mm² , Lt Distribution Box For 25 Kva Dtr With 40 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 25 annual periodical maintenance Mccb 3P 16 Ka/10 Ka 1 No. Each (=2No.) For Outgoing Circuits . , Lt Distribution Box For 63 Kva Dtr With 100 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 63 annual periodical maintenance Mccb 3P 16 Ka 1 No.S For Outgoing Circuits , Lt Distribution Box For 100 Kva Dtr With 160 Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 200 Kva Dtr With 315 annual periodical maintenance Mccb 3P 25 Ka For Incomer & 160 annual periodical maintenance Mccb 3P 16 Ka 3 No.S For Outgoing Circuits , Lt Distribution Box For 250 Kva Dtr With 400 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 160 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Temporary Lt Fuse Set For Distribution Transformers (Customised) As Per Kpdcl Drawing No. Ce/P&P/Drg/2023/Ltfs/001 (Enclosed) , 11Kv Polymeric Composite Disc Insulator 12Kv,Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm Nos , 11Kv Polymeric Composite Pin Insulator 12Kv, 5Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 16 Kn Polymer Shackle Insulator , G.I Mukey For Shackle Insulators With Bolt Of (50X8)Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 258 Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 369 Mm , 11 Kv Link Set Heavy Duty With Copper Blade Size Of 14 Inch, 50 X 6 Mm, Female Contact Of Copper 6 Mm Thickness, With Post Insulator Of 10 Kn , 11 Kv Go, Ab Switch 3-Phase, 3-Pole,200 Amp, Vertical Type Set , 11 Kv Horn Gap Fuse Set 3 Phase 200A Set , Pg Clamps For 30 Mm² Acsr Conductor , Pg Clamps For 50 Mm² Acsr Conductor , Pg Clamps For 100 Mm² Acsr Conductor , Suspension/Tension Clamp With Eye Hook , Gi Pole Support Clamp Including Gi Nut And Bolts For 11 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 9 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr With Size 50X 8X 328 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr Or 9 Mtr Plain Cement Concrete With Size 50X8x441mm , Cable Tie (Each Packet Contains 100 Nos.) , Cable End Caps , Insulating Piercing Connectors Of Sizes , 11 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 11 Kv Ipc For Covered Conductor To Covered Conductor Connection , 33 Kv Tension Clamps With Bail And Ipc (Insulation Piercing Conductors) , 33 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 33 Kv Ipc For cement concrete To cement concrete Connection , 33 Kv Ipc With Aluminium Bail For Earthing , Main Single Phase Service Distribution Box (Pole Db) Along With Mccb /Mcb As Per Rec Drawing. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Main 3 Phase Distribution Box Ip 54 (Pole Db) Made From 20 Swg Crca Ms Sheet By Deep Drawn Method With Powder Coating. Internal Size Of The Box Shall Be 225Mm X 285Mm X 120Mm Used For Connection Through Abc Line And For Giving Connections To The Consumers 3Phase-1 Incoming 4 Outgoing I/C- 1, O/G-2-4 (200 A, 0.415 Kv) For Ryb Phase. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Lt Line Spacers 3 P ,4 Wire , Lt Line Spacers 2 P ,3 Wire , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 3-Ø, 4-Wire Trivector Meter (Prodigy ) With Suitable Ring Type Ct 200 annual periodical maintenance (Net Meter Enabled) , Single Phase Smart Energy Meter 5-30 Amp/ 10-60 Amp, Dlms Complaint Of Accuracy Class 1.0 , Three Phase Smart Energy Meter 20-80 Amp/, Dlms Complaint Of Accuracy Class 1.0 , Polypropylene Weather Proof Outdoor Type Meter Box For Single Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For Three Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For 4 Single Phase Meter Along With Zinc Plated Clamps , Gi Barbed Wire For Anti Climbing , Danger Plates With Clamps , Anti-Climbing Device With Clamps , Cemical Earthing Complete , Earthing Mat (Gi Flat 50 Mm X8 Mm)/(75 X10)Mm/(75X8)Mm , Gi Pipe 40 Mm 3 Mtr Long For Earthing , Earthing Electrode ( 3M Long) 20 Mm Dia. , Gi Strip 25X3 Mm , Galvanized Earthing Strips 50Mm X3mm. , Red Oxide , Aluminium Paint , Galvanized Nuts And Bolts , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2No..), Anchor Plate (200X 200 X 6 Mm), Nut-Bolts, 2 No. Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (11 Kv) , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2Nos.), Anchor Plate (300X 300 X 8 Mm), Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (33 Kv) , Gi V Cross-Arm With Top Bracket Of Sizes , Gi Channel X-Arm And Braces Of Sizes , Gi Extension Riser Of Sizes , Gi Wire 6 Swg & 8 Swg , Guard Netting (For 52 Mtr Span) , Aluminium Jointing Sleeves 100 Sqmm , Aluminium Jointing Sleeves 50 Sqmm , Aluminium Jointing Sleeves 30 Sqmm , Suspension Fitting (2 Bolt) For 11 Kv Line , Tension Fitting (4 Bolt) For 11 Kv Line , Suspension/Tension Clamp With Eye Hook , Earth Wire 7/4 Sqmm , 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation, Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Service Pillar. , 3 Phase, 415V, 1No Of 250 Amps Incoming 3 Tp Mccbs (Breaking 36Ka) Fitted Withoutgoing 03 No 100 Amps Sp Mccbs, 1No.100Amps 3 Pole Mccb For Outgoing Lt Cables, Distribution Feeder Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 4P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Feeder Pillar. , Fire Extingiusher Co₂ Type Of 4.5 Kg Capacity For Control Room , 3 Sand Bucket Fire Extingiusher , Gum Boots With Steel Toe Of Sizes , Winter Jacket- Coat Ecc Consists Of Three Independent Components That Is Wind Cheater ( Waterproof ), Insulating Layer And Waist Coat ( Sleeve Less ), Three Layer Waterproof Breathable Fabric, Dual Shade Og/ White, Material Of Insulating Layer- 1. Batting Polyester, 100 Gsm, 2. Fabric Nylon Knitted Aluminized, 3. Fabric Nylon 75 Gsm White, Material Of Waist Coat- Double Layer Bonded Polyester Fleece , Safety Vest - Reflective Luminous Garments - High Visibility Warning Garments With Synthetic Slide Fasteners, Fluorescent Yellow, Width Of Retro Reflective Material For All Types Of Garments (Minimum) 50 Millimeter , Non-Contact Voltage Detector, Upon Detection, Tip Glows And Beeper Sounds, Cat Iv 1000 V For Added Protection, Expanded Range: 90 V To 1000 V Ac Or 200 V To 1000 V Ac, Battery Cell Operated (2 Aaa Or Standard), Voltbeat Technology And Continuous Self-Test , Safety Helmet- Quality Of Shell High Quality, High Impact, Light Weight,Tough, Conformity To Specification- Is 2925:Latest ,En 397 Certified , Safety Rubber Gloves Up To 15 Kv As Per Iec Standard , Safety Belt/Harness With Shock Absorber , Safety Shoes Of Sizes -Personal Protective Equipment - Safety Footwear As Per Bis Specification No Is 15298 ( Part 2 ): 2016, Toe Cap- ( Steel ) Metallic, Insole, Classification- Class I ( Footwear Made From Leather And Other Materials, Excluding All-Rubber Or All-Polymeric Footwear ) With Different Sizes, Slip Resistant- As Per Clause 5.3.5.4 Of Is 15298 ( Part 2 )- Slip Resistance On Ceramic Tile Floor With Nals And On Steel Floor With Glycerine. , 11 Kv Earthing/Discharging Rod (Set Of 3 Rods) Set With Minimum 20 Sqmm Cable And U-Clamp , Battery Operated 12 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Alumunium Ladder 2*15 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Aluminium Ladder 2*10 Ft Long, Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope , Bamboo Ladder 18 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Bamboo Ladder 20 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Wart Free Budloo Wooden Ladder 17 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Wart Free Budloo Wooden Ladder 20 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Telescopic Ladder 20 Ft Long, 6063 T5 Grade Of Aluminium , 150 Kg Load Capacity, Self Locking Mechanism, Anti-Skid Foot Caps , Hand Held Search Light Led Lamp, 100 Watt With Lithium Ion 3.7 V, 3.5 Ah, 500 Lux/100 Mtr With Lamp Life -50000 Hours, Ip 65, 12 Months Warranty , Hdpe Pipe Outer Dia 180 Mm Inner Dia 152 Mm For Laying Of 11Kv Xlpe Cable From Power Transformer To Control Room , Mccb - 200 Amps,36Ka,4P Adjustable , Mccb - 40 Amps,36Ka,4P Adjustable , Mccb - 63 Amps,36Ka,4P Adjustable , Mccb - 100 Amps,36Ka,4P Adjustable , Mccb - 160 Amps,36Ka,4P Adjustable , Mccb - 250 Amps,36Ka,4P Adjustable , Mccb - 400 Amps,36Ka,4P Adjustable , Mccb - 630 Amps,36Ka,4P Adjustable , Mccb - 200 Amps,36Ka,3P Adjustable , Mccb - 100 Amps,36Ka,3P Adjustable , Mccb - 160 Amps,36Ka,3P Adjustable , Mccb - 250 Amps,36Ka,3P Adjustable , Mccb - 400 Amps,36Ka,3P Adjustable , Mccb - 630 Amps,36Ka,3P Adjustable , Bobin Insulators Clamps/Cliffs. , Epoxy Resin Cast Panel Insulators Upto 500Mm , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Al. Solderless Clamps Suitable For Transformer 1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 63 Kva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 50 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , Aluminium Thimbles 10 Mm2 As Per Relevant Is , Dpc Copper Winding Wire (Round) In Sizes 11 To 22 Swg Fresh. , Dcp Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 250 Kva To 630 Kva Fresh. , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg. , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg-Fresh , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva - Fresh , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg-Fresh , Dpc Copper Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Lv Brass Bush Rods 12 Mm , Lv Brass Bush Rods 19 Mm , Lv Brass Bush Rods 25 Mm , Lv Brass Bush Rods 32 Mm , Press Card Board Soft Calendared Solid 1Mm/2Mm/3Mm(As Per Sample) , Press Card Board Pre Compressed Solid 1Mm/2Mm/3Mm. , Ht Insulating Gum , Glass Wool Sleeves Of Sizes , Aluminium Brazing Rod (Standard Length) , Copper Brazing Rod (Standard Length) , Flexible Copper Strip (Shim) 75Mm X 0.5 Mm , Pvc Sheets 1 Mm Thick , Empire Tape 1 , Electrical Grade Kraft Paper, 4 Mil , Leatheroid Insulation Paper 20 Mil. , Hv Bushing , Lv Bushes Suitable For 63 To 100 Kva Dt , Lv Bushes Suitable For 200 To 250 Kva Dt , Lv Bushes Suitable For 400 To 630 Kva Dt , Epoxy Resin Cast 1.1 Kv Low Voltage Transformer Bushing With Busbar For 400/630 Kva Dt , Cotton Tape 1 (Size) 35 M Long. , Rubber Washers , Ht Paper , Cork Washer 12Mm Dia , Cork Washer20mm Dia , Cork Washer 25Mm/30Mm Dia , Plastic Metre Seals , Trifor (Tower Roller) , Transformer Oil Filitration Plant Filter Elements Of 1 Micron(60X250) Mm For Transformer Oil Filitration Plant , Heating Elements Of 2000 Watts For Transformer Oil Filtration Plant , Press Cardboard Cutter Having Bed=52X21 With Height Of Machine 45 With No. Of Tensile Springs 2 Nos. Complete In All Respects. , Angle Grinder, 800W Power, No-Load Speed Of 11000 Rpm, 100 Mm Disc , Welding Machine(Inverter Type) =5=10 Kva Rated Input Power, Maximum Welding Current At 60% Duty Cycle (In A) 150=250, Adjustable Hot Start,Anti-Stick Functions,Arc Force Control , Cordless Impact Drill/Drivers With 2 Batteries, Ideal For Driving Screws Into Wood And Drilling Into Masonry, Metal, And Wood , Pneumatic Air Impact Wrench With Sockets From 15 To 30 , Air Compressor 50 Ltr , Hand Held Brush Cutter , Hydraulic Crimping Tool , Pallet Truck 3 Ton , Hand Driven Insulation Resistance (Meggar) , Multimeter(Analog) , Multimeter(Digital) Voltage: Dc: 1000 Volts; Ac: 1000 Volts; Dc Accuracy: ± 0.5% + 3 Digit; Ac Accuracy: ± 1% + 3 Digit; Current: Dc: 10 Amps; Ac: 10 Amps; Dc Accuracy: ± 1.5% + 3 Digit; Ac Accuracy: ± 1.5% + 3 Digit; Resistance: 40 M Ohm; Resistance Accuracy: ± 1.5% + 3 Digit ; Capacitance: 1000 Μf; Capacitance Accuracy: ± 5% + 5 Digit Cat Iii 600 Volts Safety Rating , Pliers -Type Of Hand Tool-Combination Plier As Per Is 6149, Type Of Insulation-Rubber Insulation, Material-Carbon Steel , Nawara Tape 1 (Size) 35 M Long. , Rubberized Cork Sheet 4 Mm Thick 2Ftx3ft , Rubberized Cork Sheet 3Mm Thick 2Ftx3ft , Bakelite Tubes 12Mm Dia ( 1 Mtr Long) , Hv Bush Clamps (Ms) , Aluminium Clamping Member (Shoes) For Hv Bushing , Lv Cork Washers 12 Mm Dia , Lv Cork Washers 20Mm Dia , Lv Cork Washers 25 Mm/30 Mm Dia , Nuts & Bolts (M.S) Of Sizes. , M.S Flat Washers. , Hv Cork Washers 110 Mm O.D , Aluminium Welding Flux , Aluminium Flat 4/6/8/10 Mm Thick Of Required (Busbar) , Copper Flat 4/6/8/10 Mm Thick Of Required Width. (Busbar) , Ms Plug & Caps 1/2 ; 3/4; /1; 1.1/4; 1.1/2 , Oil Seal Rings (O-Rings) For Lv/Hv Bush Rods 12 Mm Dia. , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 20 Mm Dia , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 25 Mm Dia , Creep Tape 1 , Cotton Cloth , Empire Sleeves Of Sizes , Synthetic Enamel Paint Smoke Grey Colour , Paint Thinner , Steel Primer , Silica Gel , Transformer Oil As Per Is 335 And Amendments Thereof , Welding Rods 3.15 Mm/4Mm. (100 No. Per Packet) , Refilling Of Oxygen Gas For Brazing , Refilling Of Lpg Gas For Brazing , 12 Piece Tool Kit (1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench(Adjustib And 1-Piece Measuring Tape) Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 12 Volts, 42 Ah Lead Acid Battery , 12V 7 Ah Rechargeable Sealed Maintenance Free Battery (Smf) For Ups , Battery Connector For 12 V Battery Bank (12 No. Both Ends Of Each Connector Should Be Properly Clamped With Nuts, Bolts, Washers) , Fabricated Gi Pollar Collar 50X6 Mm With Nuts And Bolts , Digital Weighing Scale Upto 1 Ton , Portable Professional Petrol Chainsaw,18 Inch Or Above, 2 Kw Or Above, Pitch Of 3/8 Or Above, Petrol Capacity 400 Ml Or Above. , Double Ply Polyester Webbing Slings, Load Capacity 6 Tonne , Dee Shackles Forged Shackles, Working Load 6.5 Tonne , Eyebolt With Recessed Collar With Maximum Axial Lifting Capacity Of 6 Tonne , Handheld Brush Cutter / Line Trimmer, With Nylon Feed Head Attachment Petrol Engine Low Vibration Centrifugal Clutch, Hardened Steel 2 Teeth Blade, Bump / Tap & Go Type, Shaft Length (Mm) 1425 To 1449, Circular Saw Attachment Inclusive In The Scope Of Supply , Portable Hydraulic Crimping Tool For 30 Sqmm To 400 Sqmm With All Attachments , Pre Fabricate Galvanized Single Way Top Bracket (1000 Mm Long With 48.3 Od Gi Pipe) To Be Fitted On Top Of Octogonal Pole For Holding Lighting Luminaries. , Dk Thermoplastic Cable Junction/ Termination T Boxes 8X10Of Class Ip55/Ip65 Fitted With Two 2-5 annual periodical maintenance Mcb Strip,4-Way Terminal Block / Connectors Incl. Copper Lugs, Clamps ,Nut & Bolts Washers Etc (Hansel Or Equivalent Make) Or Poles With Two Way Type Bracket To Be Fitted Properly Inside The Door Opened Gear Box Provided On Thebottom Side Of The Pole. , Surge Protector For The 120/190 Watt Led Type Lighting Fixture Complete. , Outdoor Type Lt Control Panel Size 900Mmx900mmx450mm Having Input Main Control Of 100 annual periodical maintenance Mccb With Tpn Bus Bar With 40 annual periodical maintenance Tpn Mcb 4Nos For Outgoing Circuits,Including Astronomical Switching With Contactor Of Required Capacity. The Panel Should Be Fitted With A Digital Composite Voltmeter/Ampermeter/Indicator Set With Selecter Switch And Backup Protection System, Thimbling And The Panel Shall Further Be Provided With Proper Openings On Front Side As Well As On Rear Side Including Its Locking Arrangement And Also With Required Glands And 4No. Angle Iron Legs For Grouting The Panel On Bed , The Panel Shall Also Be Provided With Powder Coat/Pu Paint. The Item Includes Its Thimble As Required At Taping Point For Incomming , Out Going And Internal Panel Wiring Complete Unit. , Dust/Rain/Snow-Proof Canopy Type Mini-Outdoor Lt Feeder Panel Of Size 450X300mm With Front Door Opening Duly Powdered Colour Coated With Inbuilt 2No Tpn 16-32 annual periodical maintenance Mccb,Tpn Busbars Of Same Capacity Installed On Cement Concrete Block With 4 Angle Iron Legs Grouted In The Cement Concrete Of Termination Of Main 25Sqmm Cable And Outgoing 25/16 Sqmm Cable Circuits. , 120 Watt Led Luminaries Of Ip 67 Protection. , 190 Watt Led Luminaries Of Ip 67 Protection. , 110 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 70W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 50 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 30W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 6 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 10 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1Pole With 1Pp, 240 V , 10 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 240 V , 16 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 16 A Spn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2Pole With 1Pp, 415 V , 16 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3Pole With 3Pp, 415 V , 32 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , 32 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3 Pole With 3 Pp, 415 V , 32 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 415 V , 32 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1 Pole With 1 Pp, 415 V , 63 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , Astronomical Timer For Street Light Control, 3 Phase, 18 Kw/43 A Each Phase, Ip 66, Manually Settable Timer With 12 Programmes Spreaded Over A Year As Defined Programme, 260 Volt +/- 5 Volt Over Voltage Protection Per Phase, 160 Volt +/- 5 Volt Under Voltage Protection Per Phase, Operating Temperature Range -10 To +50 Deg C, /=60 Seconds On/Off Timing Accuracy , Embossing Punch Die Tool For Dt Coding (A-Z And 0-9) , Battery Operated Engraving Machine , Hand Operated Oil Pump/Barrel Pump , Manilla Rope - 25 Mm , Nylon Rope- 20 Mm , 11Kv Pilfer Resistant Metering Cubicle For 3Phase 4 Wire Metering System Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Panel Having Two Compartments Upper Meter Compartment And Lower Ct/Pt Compartment. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Sufrace, Dust, Weather And Vermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangments. The Metering Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening The Lv Chamber Door. , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 2.5 /5 For 25Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 5/5 For 63Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 7.5/5 For 100Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 15/5 For 200Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 20/5 For 250Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 25/5 For 400 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 50/5 For 630 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 75/5 For 1 Mva Dt , 11Kv/ 110 V, Three Phase Epoxy Resin Cast Pt With Rated Burden 15Va Per Phase And Accuracy Class 0.5 Or Better And Conforming To Is:3156 (Part-I&Ii) Amended Upto Date With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And Withstand Separate Source 23Kv providing fixing For One Minute. , 3Ph, 3 Wire Ht Ct/Pt Operated Fully Static Smart Tri-Vector Energymeters Dlms Compliantcategory C With Rs232 Port For Modem Compatibility. 11Kv/110V, Ph-Ph (3P,3W) Metersfor Measurement Of Different Electrical Parameters Including Active Energy (Kwh/ Mwh), Reactive Energy (Kvarh/Mvarh), Apparent Energy (Kvah/ Mvah) Etc. (Make L&T, Secure,Abb) , Led String Light 15 Mtr Long Of Different Colours (Saffron/White/Green) With Controller. , 4 Socket Extension Boards With Each Compatible Sockets Of 16 annual periodical maintenance And 5 Mtr Long Cable And Plug Along Surge Protector And On/Off Controller.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
23.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
27.
Rural Development #11035862 AOC
Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Kuruli Tal Khed Dist Pune- Supplying and erecting modulartype switch6A / 10A 2 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length 3 Providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2) 4 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.OH-PL/STP 5 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in 6 Supplying and erectingLED street light fitting suitable for 36w TO 40w LED Street Light, including lamp, with PF > 0.95 class IP 65 . 7 Supplying and erecting LED street light fitting suitable for 50W lamp, including lamp, with PF > 0.95 class IP 65. 8 Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65. 9 Supplying and erectingLED street light fitting suitable for 90 w LED Street Light, including lamp, with PF > 0.95 class IP 65. 10 Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 11 Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 12 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 13 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 14 Labour Chrages for LED fitting on Street light or MS light pole. 15 Dismentaling Charges -LED street light of pole. 16 1.25 mm CRCA sheet metal enclosures box for Timmer and MCB 17 Supplying PVC insulated PVC round sheathed 1.5 sq.mm 18 Supplying & Laying armoured cable 4C X 6 Sq.mm. 19 Supplying & Laying armoured cable 4C X10 sq mm 20 Supplying & Layingarmoured cable 2C X 10 sq mm 21 Supplying & Layingarmoured cable 2C X 6 sq mm 22 Supplying & Layingarmoured cable 4C X 16 sq mm 23 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 24 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 25 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 26 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 27 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 28 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 29 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole. 30 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 31 Supplying and erecting mains with ISI mark WP2 x 2.5 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 32 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 33 25 Amp, 32 Amp Three Phase L/T Contactor 34 2.5 Sq. mm Multistand Copper Wire 35 Insulation Tape 36 Water Proof Tape 37 Street Light Pole Box FRP 38 Cement Street Light Pole Clamp 39 M.S. Street Light Pole Clamp 40 LED Street light Arm bend pipe 41 Small Size FRP box for MCB 42 Big Size FRP box for MCB 43 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 44 Servicing And Primary Maintenance For Street Light Pole. 45 Light Poles painting in Silver Colour 46 26W LED Light To 100W LED Light Repairing 47 Old Pole Shifting, Rework and Foundation Work per Pole etc. 48 Supply &Fixing of Shakle Hardware with Nut Bolt 49 Supply and Installation of Mini Feeder Pillar with Stand 50 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 51 Tree Triming for Overhead Line 52 Tree Triming for Overhead Line 53 7-1-33 Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor 54 7-1-31 Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm aluminium conductor 55 7-1-34Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm aluminium conductor 56 7-1-35 Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm aluminium conductor 57 5-3-5 Supplying, erecting & marking SPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 58 5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 59 5-3-29Supplying, fixing and commissioning MCB type change over switch 2 pole, 63 A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 60 5-3-32 Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 61 7-9-4 Supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. CB-CL/CU 62 7-9-5 Supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. CB-CL/CU 63 7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. CB-CL/CU 64 4-4-5 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 65 Cable Joint Kit for armoured cable 20 upto 120Sq. MM Cable 66 GI Tar for service wire support with bobine. 67 Kit kat Type fuse 16A 32A 63A 120A 68 Taparia Tester 69 Spaner Set 70 Control Panel HRC Fuse 71 Supplying And Erecting Transformer Fidder Piller 72 5-2-19 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation. 73 Bag filtter for 250/500/1000 LPH RO plant 74 Small cartridge filter 75 Big size cartridge filter 76 Coin mechanisum unit 77 Aster RO ATM unit 78 MECH-101 RO membrane cleaning chemical liquit -5 ltr 79 Supplying and erecting MS Pole Bracket 1100mm long (65-65-6) 80 Supplying and erecting aluminium standed cunductors 7/3.10 mm (Ant.) 145 Kg/Km) 81 Supplying and erecting ACSR aluminium standed cunductors 6/1-2.59mm Kg/Km 82 Supplying and erecting GI stay set for Pole including loops insulators height with achor plate 300x300x6 mm GI Wire 7/8 SWG 83 Supplying and erecting RSJ (Girder) Pole 125 x 70 mm (13.3Kg/m) 84 Supplying and erecting shackle type LT medium insulator 75x115 mm dia. With GI streep Nut Bolts etc 85 Supplying and erecting aluminium bobbin With GI streep Nut Bolts etc 86 Providing earthing with galvanized iron earth palte 60 x 60 x 0.6 cm with all materials 87 sand and Carban
Contract Date: Jul 28, 2025 Contract Value : 2.52 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
28.
Tourism #10977010 AOC
Tender for Cables, Earthings , Supply Of 4 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 1.5 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 10 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 25 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 1.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately).(A) In Soily Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Supplying And Laying 25 Mm X 5 Mm Gi Strip In 40 Mm Dia Gi Pipe From Earth Electrode As Required , Supplying, Of Hdpe Pipes At Store Or Site Of Work Including Loading, Unloading, Stacking, Transit Insurance Etc. Complete Bearing Isi Mark &Conforming To Is: 4984-1995 & Made From Pe 100 Resin Class Iv (6 Kg/Cm2). Outer Dia. 90 In Mm , Foundations , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A) All Kinds Of Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing. All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Foundations, Footings, Bases For Columns , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Levelm-20 Grade Of Concrete , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Levelm-25 Grade Of Concrete , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Levelm-30 Grade Of Concrete , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Dbs, Mcbs, Terminations, Wiring/Lights , Supplying And Fixing Following Way Tpn Sheet Steel, Single Door, Verticle Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)Interconnection Between Incomer Mccb And Busbars Of Following Ways (But Without Mcbs As Required)(A) 4 Way (8+12), Single Door, Vertical Type, Cat A , Providing & Fixing G.I. Pipes Complete With G.I. Fittings & Clamps, Including Cutting And Making Good The Walls Etc. (Internal Work)25 Mm Nominal Bore , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(4) 4 X 10 Sq. Mm. , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Medium) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supply And Erecting Of 48 Inch (1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying & Erecting Led 20W Tube Light Fitting (4 Feet), 5700K, With Crca Housing, Heat Sink, With Industrial Grade Heavy Duty Driver Complete Havels Cat Stout Mini 1200Bs 40W Led 865 Make Philips / Wipro Cat No Ll24-541-Xxx-57-Cd (Including Lamp) , Supply, Installation , Testing And Commissioning Of 12W Uplighter Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of 15W Uplighter Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of Wall Washer Of 36W Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of Wall Washer Of 20W Including Driver Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: White Of Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of 2 Mtr Corner Profile Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of 1 Mtr Corner Profile Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Warm White Make: Atilite, Wipro, Transrail, Bmp. , Supply, Installation , Testing And Commissioning Of Decorative Wall Fixtures Of 50W Of Ip 66 As Required As Directed By The Engineer Incharge Of Colour Output: Whitemake: Atilite, Wipro, Transrail, Bmp. , Supply And Fixing Of Junction Box Of Model Dk 1000G Of Size 130X180x77 Hensel Box As Required As Directed By The Engineer Incharge , Supply And Fixing Of Junction Box Of Model Wp 0402G Of Size 104X104x70 Hensel Box As Required As Directed By The Engineer Incharge. , Supply And Laying Of 14 Swg Copper Wire , Supply And Laying Of 25Mm Rigid Pvc Pipe Hms , Supply, Installation , Testing And Commissioning Of Outdoor Stand Mounted Feeder Pillar Ip66 Rated With 32A Tpn Mcb Incomer, Single Dial Timer, 25A Cotactor For Automatic Switching Of Luminaries .Of Make L &T/Schneider/Havells /Legrand, Incoming 10 Sq.Mm And Outgoing 2.5Sq.Mm Terminals With Outgoing Mcbs 6 Nos. The Panel Should Be Cpri Approved As Required As Directed By The Engineer Incharge. , Supply And Installation Of Driver Of 150W Make Meanwell, Philips As Directed By The Engineer Incharge , Supply Installation Testing and Commissioning of Decorative 3Mtr Height Post Top Gi Pole Made Up Of Aluminium With Pure Polyster Power Coating. Pole Dia Of 60Mm With Base Plate Of 200Mmx200mm. Having Halo Ring Design Fixture Of 50W. Ip66. With Inbuild Driver Of Philips Make. Input Surge Protection: 6Kv. Power Factor: 0.90. Cri: 80. Operating Voltage: 80-240V Ac, 50-80Hz. Make: Transrail, Wipro, Bmp. , Supply, Fixing, Testing And Commissioning Of 350W Led Flood Light Luminiare Ip 66 Optic Compartment, Pressure Die Cast Aluminium Housing, Control Gear Compartment, Frame With Toughened Glass With Luminious Efficacy 115 Lumen/W At Ta 25 Deg C.In Built Surge Protection Upto 10Kv As Required And Directed By Engineer Incharge. Make Transrail,Wipro, Atilite. , Supply, Fixing, Testing And Commissioning Of 50W Led Flood Light Luminiare Ip 66 Optic Compartment, Pressure Die Cast Aluminium Housing, Control Gear Compartment, Frame With Toughened Glass With Luminious Efficacy 115 Lumen/W At Ta 25 Deg C.In Built Surge Protection Upto 10Kv As Required And Directed By Engineer Incharge. Make Transrail,Wipro, Atilite. , Supply, Installation, Testing And Commisioning Of 20 Mtr High Mast System With Head Frame, Galvanized Lantern Carriage. Mast Shaft Shall Be In Two Sections, Hot Dip Galvanized And Suitable For 44(Mtr/Sec) Wind Velocity As Per Is 875, The Mast Shall Have An Integral Powertool Installed Inside The Base Compartment For Its Operation. It Shall Include Accessories For High Mast Including Steel Wire Rope 6 Mm Dia(7/19 Construction ), Trailing Cable (5 Core 2.5 Sq.Mm), Double Drum Winch, Connector, Integral Power Tool Motor, Manual Handle For Lowering And Rasing Mechanism, Junction, Box Etc. Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of 12.5 M High Mast With Head Frame, Mast Shaft Shall Be In Two Sections, Hot Dip Galvanized (Avg Microns On Hm Shall Be 100 Microns Taking Into Consideration Of Coastal Beach Line) Suitable For Wind Speed 44M/Sec Wind Velocity As Per Is 875,Galvanized Luminaries Carriage Suitable To Install 6-8 Nos.Luminaries (350 W Fixtures) In Symmetrical Arrangement, The Mast Shall Have An Integral Powertool Installed Inside The Base Compartment For Its Operation, Lightning Finial Along With The Other Accessories Like Double Drum Winch, 6 Mm Diameter Ss Wire Rope,Trailing Cable (5 Core 2.5 Sq.Mm),, Connector, Integral Power Tool Motor, Manual Handle For Lowering And Rasing Mechanism, Junction, Box Etc. Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply Of 9M High Mast Shaft In Single Sections Suitable For Wind Speed 47M/Sec. With Head Frame, Luminaries Carriage Suitable To Install Upto 6 Nos. Luminaries In Symmetrical Arrangement, Lightning Finial,Along With Supply Of Accessories Required Such As Double Drum Winch, 5Mm Diameter Ss Wire Rope, Trailing Cable, Connector, Integral Power Tool Motor, Manual Handle, Junction Box Etc. (Supply Of Bottom Mcbs, Top Junction Box, Top Distribution Cable For Light Fixture And Cables From Panel To The Base Of The Mast Shall Not Be In Our Scope) Make: Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of Foundation Bolts For 20Mtr High Mast Manufactured From Special Steel Along With Nuts, Washers, Anchor Plate And Suitable Template Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of Foundation Bolts For 9Mtr And 12.5Mtr High Mast Manufactured From Special Steel Along With Nuts, Washers, Anchor Plate And Suitable Template Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply, Installation, Testing And Commisioning Of Of Single Dome Aviation Obstruction Light Complete As Required And Directed By Engineer Incharge. Make :- Transrail, repair renovation Ispat, Vakrangee, Valmount. , Supply Installation Testing and Commissioning of Outdoor Stand Mounted Feeder Pillar With 32A Tpn Mcb Incomer, Single Dial Timer, 25A Cotactor For Automatic Switching Of Luminaries , Power Tool Control With 2 No. 9A Contactors And Raise Lower Push Button, Incoming 35 Sq.Mm And Outgoing 16 & 2.5Sq.Mm Terminals With Outgoing Mcbs 6/8 Nos. With Meter Provision.
Contract Date: May 15, 2026 Contract Value : 4.09 Crore
Government Departments No of Bidders 3
30.
Health and Family Welfare #10901538 Price Bid
Tender for Volume V - Bill Of Quantities Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder General Abstract Sl.No Description Amount (Excl.Gst) , Civil Works , Plumbing Works , Electrical Works , Elv Works , Fire Fighting , Stp (50 Kld) , Building Signages Total Amount (Excl Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Civil Sl No. Dsr/ Morth Code Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , 2.6.1 , 2.26.1 , 2.26.1X2 , 2.8.1 , 2.10.1.2 , 50.2.26.1 , 4.1.2 , 4.1.8 , 4.2.5 , 5.1.3 , 5.9.1 , 5.9.2 , 5.9.3 , 5.9.5 , 5.9.6 , 5.9.7 , 5.9.16.1 , 5.9.19 , 5.11.1 , 5.22.6 , 5.22A.6 , Dsr Analysis 5.33.1.2 , Dsr Analysis 5.33.2.2 , Dsr Analysis 5.33.1.1 , Dsr Analysis 5.33.2.1 , 50.6.2.1 , 50.6.1.4 , 50.6.1.5 , 50.6.1.6 , Dsr Analysis , Dsr Analysis , 7.1.1 , 8.2.2 , Dsr Analysis , 8.3.2 , Dsr Analysis , Dsr Analysis , Dsr Analysis , 11.3.1 , 11.6.1 , 11.20.3 , 11.41.2 , 11.46.2 , 11.41A.3.1 , Dsr Analysis , Dsr Analysis , 11.56.1 , 12.52.3 12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Size 595X595 Mm Made Of Gypsum Plasterboard , Manufactured From Natural Gypsum As Per Is 2095 Part I And Laminated With White 0.16 Mm Thick Fire Retardant Pvc Film On The Face Side And 12 Micron Metalized Polyster On The Back Side With All Edges Sealed With The Face Side Pvc Film Which Goes Around And Wraps The Edges And Is Bonded To The Edges And The Back Side Metalized Polyster Film So As To Make The Tile A Completely Sealed Unit. Sqm 232.88 29 0.0 , 12.52.1 Gi Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of Gi Sheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending Sqm 1235.61 29 0.0 , 12.59.1 Calcium Silicate Board To Ceiling Section And Perimeter Channels With The Help Of Day Wall Screws Of Size 3.5X25mm At 230Mm C/C, Including Jointing Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compounds, Jointing Tapes, Finishing With Jointing Compounds In Three Layers Covering Up To 150Mm On Both Sides Of Joints And Two Coats Of Primer Suitable For Boards, All As Per Manufactures Specification And Also Including The Cost Of Making Opening For Light Fittings, Grills, Diffusers, Cut Outs Made With Frame Of Perimeter Channels Suitable Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With 8 Mm Thick Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process. Sqm 782.57 29 0.0 , 13.1.1 , 13.4.1 , 13.16.1 , 13.33.1 , 13.22 , Dsr Analysis , 13.43.1 , 13.45.1 , 13.47.1 , 13.60.1 , 13.61.1 , 13.9.1 , 13.21 , Dsr Analysis , 10.6.1 , 10.16.1 , 10.18 , 10.25.1 , 10.25.2 , 10.26.3 , Dsr Analysis , 10.28 , 21.1.1.2 , 21.1.2.2 , 21.2.2 , Dsr Analysis , Dsr Analysis , 21.3.3 , Dsr Analysis , Dsr Analysis , 9.1.1 , 9.5.1.1 , 9.7.1 , 9.71.2 , 9.21.1 , 9.22.1 , 9.24.1 , 9.74.1 , 9.48.2 , 9.97.2 , 21.13 , 9.100.1 , 9.101.2 , 21.4.1 , 9.121 , 9.122.2 , 50.9.15.2 , 9.147A.1 , 9.147A.2 , 9.147A.3 , 9.147A.4 , 9.147A.5 , Dsr Analysis , Dsr Analysis , 21.11.3 , 21.15.2 , 22.4.1 , Dsr Analysis , Mr Door Leaf Should Be Minimum 60Mm Thick Fully Flush Double Skin Door. Door Leaf Must Be Manufactured From 1.2Mm(18 Gauge) Thick Galvanised Steel Sheet. The Infill Material Shall Be Honeycomb Craft Paper Insulation. All Doors Shall Be Factory Prepped For Receiving Appropriate Hardware And Provided With Necessary Reinforcement For Hinges, Locks, And Door Closers. The Edges Should Be Interlocked With A Bending Radius Of 1.4Mm. For Double Leaf Doors Integrated Astragals Has To Be Provided On The Meeting Stile For Both Active And Inactive Leaf. The Shutters Shall Be Mounted To The Frame With Ss 304 Grade Ball Bearing Type Hinges Of Size 100X89x3 Mm Along With All Suitable Hardware (Triple Point Panic Bar, Ss Ball Bearing Hinges, Door Closer, Panic Trim, 6Mm Thick 300X400mm Vision Panel Fire Clear Glass, Etc Complete). Vision Lite Glass Size 300Mm X 400Mm (Max Area Upto 0.12Sqm) Wherever Applicable Should Be Provided With Single Layered Clear Fire Rated Glass Panes As Per Guidelines Laid Down Under Is 3614 : 2021 Vide Clause No. 7.2.7 Table No. 2 With A Clipon Arrangement. The Glass Will Be Provided With Fire Rated Ceramic Tape Of Suitable Size Alround On Either Face. Every Glass Pane Must Carry A Permanent Marking Of Approved Make. Door Must Be Tested With Vision Panel- 6Mm Thick Pyroswiss Glass Of Approved Make.Single Leaf Door. Size : 1000X2250mm Each 7.0 29 0.0 , Mr Door Leaf Should Be Minimum 60Mm Thick Fully Flush Double Skin Door. Door Leaf Must Be Manufactured From 1.2Mm(18 Gauge) Thick Galvanised Steel Sheet. The Infill Material Shall Be Honeycomb Craft Paper Insulation. All Doors Shall Be Factory Prepped For Receiving Appropriate Hardware And Provided With Necessary Reinforcement For Hinges, Locks, And Door Closers. The Edges Should Be Interlocked With A Bending Radius Of 1.4Mm. For Double Leaf Doors Integrated Astragals Has To Be Provided On The Meeting Stile For Both Active And Inactive Leaf. The Shutters Shall Be Mounted To The Frame With Ss 304 Grade Ball Bearing Type Hinges Of Size 100X89x3 Mm Along With All Suitable Hardware (Triple Point Panic Bar, Ss Ball Bearing Hinges, Door Closer, Panic Trim, 6Mm Thick 300X400mm Vision Panel Fire Clear Glass, Etc Complete). Vision Lite Glass Size 300Mm X 400Mm (Max Area Upto 0.12Sqm) Wherever Applicable Should Be Provided With Single Layered Clear Fire Rated Glass Panes As Per Guidelines Laid Down Under Is 3614 : 2021 Vide Clause No. 7.2.7 Table No. 2 With A Clipon Arrangement. The Glass Will Be Provided With Fire Rated Ceramic Tape Of Suitable Size Alround On Either Face. Every Glass Pane Must Carry A Permanent Marking Of Approved Make. Door Must Be Tested With Vision Panel- 6Mm Thick Pyroswiss Glass Of Approved Make. .Single Leaf Door. Size : 1200X2250mm Each 9.0 29 0.0 , Mr Door Shutter: The Double Skin Single Leaf Door Shutter Shall Be Consisting Of Minimum 46 Mm Thick And Having Box Like Structure, Slots Cut And Holes Punched, For Fixing Of Hardwares With Stiffeners As Per Is: 16074 Including Resin Bonded Honey Comb Paper Core Infill Material Of Density 5 Kg/Cum. The Door Shutter Shall Be Mounted On The Frame With Ss 304 Grade Ball Bearing Butt Hinges As Per En 1935: 2002 Or Butt Hinges As Per Is 12817 Both, Of Minimum Size 100X75x3 Mm @ Minimum 4 Numbers Up To 2100 Mm/2400 Mm Height Or As Per Test Evidence,Which Ever Is More, Fixed With M6 25 Screws. All Doors Shall Be Factory Prepared For Receiving Appropriate Hardware And Provided With Necessary Reinforcement For Hardware Accessories. Hardware Accessories Fire Doorset Assembly Shall Be Provided With One Number Fire Rated Ss 304 Shaft Mortise Dead Lock, One Number 50-80 Mm Back Set With Minimum 20 Mm Square Forend With Allen Key Including Ss304 Dead Strike Plate Conforming To Is: 16015:2022/En 12209, One Number Recessed Flush Pull Handle (Ss304) Of Minimum Size 40 Mm X 120 Mm, As Approved By Engineer-In-Charge. Finishing: Both Frame And Door Shutters Shall Be Factory Finished With Polyester Powder Coating Of Minimum 50 Microns Thick And Shall Have Passed Salt Spray Test As Per Is:13871 Of Approved Colour And Shade All Complete As Per Manufacturers Specifications And As Per Direction Of The Engineer-In-Charge. Installation: The Hollow Space In The Door Frame Shall Be Filled / Injected With Fire Rated Self Extinguishing Type Polyurethane Foam (Puf) After Installation At Site Of Work. The Rate Shall Be Inclusive Of Complete Fire Rated Door Assembly, Supply And Installation By The Approved Manufacturer. Single Leaf Uninsulated Metal Fire Rated Door And Frame Of Fd 120Ud With 120Minits Integrity Only As Per Is 3614:2021-For Non Egress Application Like Area Shafts Etc Sqm 21.6 29 0.0 , 22.22 , 22.23.2 , 19.16 , Dsr Analysis , Dsr Analysis , Dsr Analysis , 15.18 , 15.7.4 , 15.9.2 , Dsr Analysis , 16.68 , 16.69 , 16.91.2 , Morth 4.1.A.1 , Morth 4.12 , Morth 5.3.1.A , Morth 5.6.1.A , Morth 5.1.A , Morth 5.2.B Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Plumbing Item No Dsr Code Details Of Item Unit Quantity Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) Plumbing Sanitory Fixrtures And Fittings , 17.3.2 , 8.10.2 , 17.10.1.1 , 17.69.2 , 17.31 , 17.72 , 17.71 , 18.21.2.1 , 18.53.1 , 18.65 , 50.17.1.2 , 17.32.4 , 18.8.1 , 18.8.2 , 18.8.3 , 18.8.4 , 18.17.1 , 18.17.1A , 18.17.2 , 18.17.3 , 18.17.4 , 12.44 , 18.48 , 17.70.1 , 19.6.3 , 19.7.1.1 , 19.8.1.1 , 19.16 , 2.10.1.2 , 19.8.2.1 , 19.7.2.1 , 19.32.1 , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Electrical Sl. No Dsr No. Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) 1. Wiring , 1.3.1 Lmr 2 X 1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire M 4185.0 29 0.0 1.3.2 Lmr 2 X 2.5 Sq.Mm + 1X 2.5 Sq.Mm Earth Wire M 8370.0 29 0.0 1.3.3 Lmr 2 X 4 Sq.Mm +1X 4 Sq.Mm Earth Wire M 1395.0 29 0.0 1.3.4 Lmr 2 X 6 Sqmm + 1 X 6 Sqmm Earth Wire M 100.0 29 0.0 , 1.4.1 1.21.1 20 Mm M 50.0 29 0.0 1.4.2 1.21.2 25 Mm M 100.0 29 0.0 1.4.3 1.21.3 32 Mm M 100.0 29 0.0 1.4.4 1.21.4 40 Mm M 50.0 29 0.0 , 1.50.1 , 1.55.3 , 15.4.3 3 Output (1 Output Per Phase) And Suitable For Three Phase Supply 2. Mccb, Mcb & Dbs , 2.3.3 2.3.3 12 Way Double Door Each 5.0 29 0.0 , 2.2.1 2.4.1 4 Way Double Door Each 14.0 29 0.0 2.2.2 2.4.2 6 Way Double Door Each 19.0 29 0.0 2.2.3 2.4.3 8 Way Double Door Each 2.0 29 0.0 , 2.3.1 2.5.1 4 Way Double Door Each 6.0 29 0.0 , 2.4.1 2.10.1 Single Pole Each 370.0 29 0.0 2.4.2 2.10.3 Double Pole Each 10.0 29 0.0 2.4.3 2.10.4 Triple Pole Each 50.0 29 0.0 2.4.4 2.10.5 Triple Pole And Neutral Each 20.0 29 0.0 , 2.6.1 2.12.1 40 Amps Each 5.0 29 0.0 , 2.7.1 2.13.1 40 Amps Each 22.0 29 0.0 2.7.2 2.13.2 63 Amps Each 11.0 29 0.0 , 2.8.1 2.14.1 25 Amps Each 5.0 29 0.0 , 2.9.1 2.15.1 25 Amps Each 4.0 29 0.0 2.9.2 2.15.2 40 Amps Each 15.0 29 0.0 2.9.3 2.15.3 63 Amps Each 15.0 29 0.0 , 2.17 2.12.1 2.24.1 Supplying And Fixing Cable End Box (Loose Wire Box) (Ip 43) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Testing And Commissioning Etc. As Required.For 4 Way, Double Door Tpn Mcbdb Each 14.0 29 0.0 2.12.2 2.24.2 Supplying And Fixing Cable End Box (Loose Wire Box) (Ip 43) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Tpn Mcbdb Each 19.0 29 0.0 2.12.3 2.24.3 Supplying And Fixing Cable End Box (Loose Wire Box) (Ip 43) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Testing And Commissioning Etc. As Required.For 8 Way, Double Door Tpn Mcbdb Each 2.0 29 0.0 2.12.4 90.11.1.15 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required 6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 4.0 29 0.0 2.12.5 90.11.1.18 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 2.0 29 0.0 2.12.6 90.11.1.19 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 2.0 29 0.0 2.12.7 90.11.1.20 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required8 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 3.0 29 0.0 3. Cable Tray , 4.6.2 , 4.6.4 , 4.6.6 , 4.6.7 4. Earthing , 5.19 5. Mv Cable Laying , 5.1.1 7.1.1 Upto 35 Sq. Mm M 1650.0 29 0.0 , 5.2.1 7.5.2 Above 35 Sq. Mm And Upto 95 Sq. Mm M 720.0 29 0.0 5.2.2 7.5.4 Above 185 Sq. Mm And Upto 400 Sq. Mm M 420.0 29 0.0 , 7.6 5.3.1 7.6.4 Above 185 Sq. Mm And Upto 400 Sq. Mm M 330.0 29 0.0 , 5.4.1 7.7.1 Upto 35 Sq. Mm (Clamped With 1Mm Thick Saddle) M 985.0 29 0.0 5.4.2 7.7.2 Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) M 175.0 29 0.0 5.4.3 7.7.3 Above 95 Sq. Mm And Upto 185 Sq. Mm (Clamped With 25/40X3mm Ms Flat Clamp) M 25.0 29 0.0 5.4.4 7.7.4 Above 185 Sq. Mm And Upto 400 Sq. Mm (Clamped With 40X3mm Ms Flat Clamp) M 50.0 29 0.0 , 5.5.1 7.8.1 Upto 35 Sq. Mm (Clamped With 1Mm Thick Saddle) M 2130.0 29 0.0 5.5.2 7.8.2 Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) M 277.0 29 0.0 5.5.3 7.8.3 Above 95 Sq. Mm And Upto 185 Sq. Mm (Clamped With 25/40X3mm Ms Flat Clamp) M 65.0 29 0.0 5.5.4 7.8.4 Above 185 Sq. Mm And Upto 400 Sq. Mm (Clamped With 40X3mm Ms Flat Clamp) M 45.0 29 0.0 , 7.9 6. Mv Cable Jointing & End Termination , 9.1.32 , 9.1.33 , 9.1.34 , 9.1.22 , 9.1.23 , 9.1.30 7. Ht Cable Jointing & End Termination , 10.4.4 300 Sq. Mm Each 4.0 29 0.0 8. Miscellaneous Civil Items , 8.1.1 14.14.1 100 Mm Dia M 50.0 29 0.0 8.1.2 14.14.2 150 Mm Dia M 140.0 29 0.0 8.1.3 14.14.4 300 Mm Dia M 250.0 29 0.0 8.1.4 14.16.3 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Il Complete With Fitting And Cutting, Jointing Etc.Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc. , Complete As Required 120Mm Dia(Od-120Mm &Id-103Mm Nominal) M 50.0 29 0.0 9. Solar , Lmr 10. Ht Panel, Ht Cable, Transformer And Dg , Lmr 11. Lt Panels , Lmr 500/5A 15Va Class 1 Resin Cast Ct - 2 Set 200/5A 15Va Class 1 Resin Cast Ct For Connection To Apfc Panel Including Necessary Size Connecting Cable - 1 Set Outgoing. 320A Fp 25Ka Mccb With Microprocessor Release With Adjustable Ol, Sc Protection And Ef Protection - 1No. 200A Fp 25Ka Mccb With Thermal Magnetic Release With Adjustable Ol, Sc Protection - 3No. 160A Fp 25Ka Mccb With Thermal Magnetic Release With Adjustable Ol, Sc Protection - 1 No. 100A Fp 25Ka Mccb With Thermal Magnetic Release With Adjustable Ol, Sc Protection - 6 No. 250A Fp 25Ka Isolator With Front Operated Handle - 1No. 12 No 3 Phase Digital Multi Function Meter To Read V, A, F, Kw, Kwh With Acc Class 1 Including Respective Feeder Rating Ct On The Incoming And Outgoing Feeders , Lmr 12. Ups , Lmr 13. Lt Cables Supply Of The Following Size 1.1Kv Grade Xlpe Insulated Pvc Sheathed, Armoured Aluminium Conductor Power Cable Confirming To Is 7098 (Part 1) Ammended Upto Date. , Lmr 14. Light Fittings & Fans , Lmr 15. External Lighting , 90.15.3.1 , 90.15.3.2 , 90.15.4.2 16. Lightning Protection System , Lmr 17. Miscellaneous , Lmr 18. Rmu & Ht Cable Laying , Lmr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Elv Sl. No Dsr No. Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) 1. Fire Alarm System , 4.6.2 , 14.16.1 , Lmr 2. Public Address System , 14.16.1 3. Cctv System , 1.21.2 , 1.53.1 , 4.6.2 , 14.16.12 , Lmr 4. Data System , 1.21.2 , 1.21.3 , 1.27.1 , 1.53.1 , 1.53.2 , 4.6.2 , Lmr 5. Telephone System , 1.18.2 , 1.21.2 , 1.24.6 , 1.27.1 , 4.6.2 , 14.16.1 , Lmr 6.Tv System , 1.21.2 , 1.21.3 , 1.24.7 , 1.27.1 , Lmr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Fire Fighting Works Item No. Item Code Item Description Qty Unit Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , 18.1.9 , 18.2.9 , 18.3.3 , 18.4.2 , 18.5.1 , 18.6.2 , 18.7.1 , 18.7.2 , 18.7.3 , 18.7.4 , 18.7.5 , 18.7.6 , 18.7.7 , 18.7.8 , 18.9.2 , 18.10.2 , 18.11.4 , 18.11.5 , 18.11.6 , 18.12.7 , 18.14.4 , 18.14.5 , 18.14.7 , 18.15.1 , 18.15.3 , 18.16.2 , 18.17.1 , 18.18.2 , 18.19.2 , 18.21.1 , 18.21.2 , 18.22 , 18.23.1 , 18.24.3 , 18.25.2 , 18.29 , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Hvac Works Item No. Item Code Item Description Qty Unit Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr A 36 Hp Nos 1.0 29 0.0 , 16.12.1 A 16.12.1.1 24G Sq Mts 150.0 29 0.0 B 16.12.1.2 22G Sq Mts 35.0 29 0.0 , 16.12.2 A 16.12.2.1 24G Sq Mts 30.0 29 0.0 B 16.12.2.2 22G Sq Mts 15.0 29 0.0 , 16.13 , 16.17 , 16.15 , Mr A 150 Mm Dia Rmts 10.0 29 0.0 B 200 Mm Dia Rmts 10.0 29 0.0 C 250 Mm Dia Rmts 20.0 29 0.0 , 16.20.1 16.20.2 Supplying, Fixing, Testing And Commissioning Of Fire Dampers In Supply Air Duct/ Main Branch And Return Air Path As And Where Required Of Required Sizes I/C Control Wiring, The Damper Shall Be Motorized And Spring Return So As To Close The Damper In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The Damper Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. Actuator Nos 5.0 29 0.0 , Mr A 200 Cfm Nos 2.0 29 0.0 B 150 Cfm Nos 3.0 29 0.0 C 100 Cfm Nos 1.0 29 0.0 D 300 Cfm Nos 2.0 29 0.0 Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Lift Works Item No. Item Code Item Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Signage Item No Dsr Code Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Mgps Sn. Item Description Unit Quantity Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr Solid Drawn, Seamless, Deoxidised, Non- Arsenical, Half Hard, Tempered And Degreased Copper Pipes As Per Tender Technical Specifications 0.0 , Line Isolation Valves , Ot Pendants (Anesthetist & Surgeon) , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Stp Item No. Item Code Item Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr Total Amount (Excl. Gst) 0.0 , Financial Bid (Part -B)-O&M And Camc For Stp & Etp Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of The Bidder: Part-B1 - O&M S.No. Project Component Cost In Inr (Excl. Gst) , Operation & Maintenance Of Entire System For A Minimum Period Of 9 Years Including Consumables And Manpower After Completion Of 12 Months Of Operation. , 1St Year , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year , 6Th Year , 7Th Year , 8Th Year , 9Th Year Total (Part-B1) (Excl. Gst) 0.0 , Part-B2 - Camc S.No. Project Component Cost In Inr (Excl. Gst) , Camc For 7 Years After Completion Of Dlp , 1St Year , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year , 6Th Year , 7Th Year Total (Part-B2) (Excl. Gst) 0.0 , Total For Part B (Part-B1+Part-B2) (Excl. Gst) 0.0 The Rates Quoted At Part B Will Be Not Be Considered For Determining L1 Financial Bid (Part -B) For Mgps Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder: Part-B - O&M For Mgps , Providing Comprehensive Maintainenace Contract For Medical Gas Pipeline System (Mgps) On Successful Completion Of Warranty , 1St Year , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year Total (Part-B) (Excl. Gst) 0.0 The Rates Quoted At Part B Will Be Not Be Considered For Determining L1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : 5.17 Lakh
Government Departments No of Bidders 3
32.
Health and Family Welfare #10834910 Price Bid
Tender For Supplying And Erecting Of 3M Height Designer Decorative Post Top Mounting Pole Made In Combination Of Galvnizing Pipe Which Is Fabricated Using 114M Dia X 3.0Mm Thick Base Section With Minimum Height Of 600Mm, The Middle Section Is Of 76Mm (+/-3%) Dia Gi Pipe With Height Of Section Is More Than 1350Mm And The Remaining Section Is Of 60Mm (+/- 3%) Dia Gi Pipe With Height Of Section Is More Than 1050Mm. The Complete Pole Shall Be Coated With Etch Primer And Further With Epoxy Zinc Phosphate Primer & Then Painted With Environmentally Stable Polyurethane Paint (Coating Thickness - 80 Microns Minimum). The Bottom And Middle Section Of The Pole Shall Be Provided With Decorative Cast Aluminium Embellishment To Add Aesthetic On The Pole As Shown In The Drawing. The Brackets Shall Be A Single Piece Assembly And Should Be Capable Of Orientation In Any Direction And Secured With Stainless Steel 304 Grade Hardware. The Pole Is To Be Provided With A Surface Mounting Suitable Base Plate Dia Of 350Mm And Suitable Thickness As Per Is Standards And Structural Reports. Decorative Ring Between Base Pole And Bracket Is Made Of Cast Aluminium Material. The Decorative Bottom Most Base Is Made Of Single Piece Cast Aluminium Material With 9W 30K Foot Light With (Ingress Protection) Ip66 Of Lamp Compartment. (All Al Casting Should Not Be In 2 Parts With Any Vertical Cuts Which Are Then Bolted Or Welded From Centre Which Spoils The Aesthetics Of The Designer Decorative Pole) With The Company / Brand Logo Embossed On It. All Dimension Is Within +/- 5% Tolerance. The Pole Should Be Provided With An Inbuilt Junction Box To Fix Four-Way Connector And 6A Mcb At The Bottom - The Inbuilt Box Should Have A Flush Door Of Suitable Size. The Decorative Pedestal To Be Mounted On A Suitable Size Steel Plate. The Mounting Plate Shall Be Provided With Elongated Holes For Alignment Of The Pole. The Suitable Size Foundation Bolt Shall Be Supply Along With The Pole Of En 8 Grade. The Manufacturer Needs To Provide A Structural Analysis For Structural Stability Of The Pole With The Relevant Is Standards Is 1239/1161/E250 Needs To Be Clearly Mentioned. The Same Needs To Be Confirmed In Form Of Test Certificates From The Manufacturer. The Manufacturer Should Have Valid Iso 9001:2015 From Ce Certification. Please Refer The Attached Drawing No - Cameroon 3M Sa Tm Pole. , Supplying And Erecting Of Decorative Luminaire Made Of Spun Aluminium Body With An Effective Heat Sink Design To Maintain The Operating Temperatures At Led Junction And Other Components Within Permissible Limits Corresponding To The Designated Design Life. The Luminaire Shall Be Provided With Highly Efficient Pc/Pmma Lens To Provide Uniform Photometric Distribution Suitable For Typical Streetlight Application And Facilitate Minimum Glare, With Degree Of Protection As Ip66 Lamp Compartment. The Luminaire Nabl 3Rd Party Report Needs To Be Attached For Ip66 And Ies File For Lighting Distribution From Goniometer And Lm79 Report From 3Rd Party Nabl. The Diffuser Shall Be Injection Moulded Polycarbonate With Ik Rating Of /=10 (With Attached Internal Ik Report From The Manufacturer) With A Diameter Of Not Less Than 285Mm And Height Not Less Than 86Mm To Maintain The Aesthetics Of The Product As Shown In The Drawing. The Design Of The Fixture Has To Be The Same Aesthetics As Shown In The Drawing. The System Ac Wattage Of The Luminaire Shall Be 30-40W (± 10%) With Mcpcb Of Not Less Than 1.6 Mm Thickness And Cu Of 35 Microns And 2.5 Thermal Conductivity For Fixture. Colour Temperature (Cct) Of 3000K, Colour Rendering Index Cri /= 70 And Residual Flux Of 70% (L70) @ 50,000 Hours At Ta Of 25°C. The Luminaire Shall Be Suitable For Operating Within Temperature Range From - 10°C To + 40°C. The Led Used Should Be High Power Leds (Make- Osram/Bridgelux/Nichia/Cree/Lumiled) With Macadam /= 5. The Luminaire Should Be Deigned To Operate At Any Voltage From 140V To 280V, With Power Factor ≥ 0.95 And Shall Be Provided With Optional Built In Over Voltage And Under Voltage Protection And Internal Surge Protection Of 4/4 Kv In Both Common & Differential Modes And External Surge Protection Of 10 Kv, Electrical Class I. The Driver Arrangement Should Be Such That It Can Be Easily Maintained Without Opening The Ip66 Lamp Compartment. All The Mounting Hardware Shall Be Ss316 Grade For Better Life. The Luminaire Shall Comply With Safety Requirements Of Applicable Bis Standard. Overall Outer Dimensions Of Luminaire Shall Be Ø540Mm (±3%) And 975Mmh (±3%) Height And The Shape Shall Be As Per The Sketch Attached And Non-Responsive And Accordingly Rejected. Approved Makes: Schreder/Reytek/Ligman. Important: In Case The Bidder Proposes Alternate Make, It Would Be Necessary To Submit A Fully Functional Sample Of The Luminaire Along With The Bid Failing Which The Bid Will Be Considered And Non-Responsive And Rejected. The Luminaire Should Be Having A Warranty For A Period Of 5 Years Against Any Manufacturing Defects. The Manufacturer Should Have Valid Iso 9001:2015 From Ce Certification. The Manufacturer Should Have Internal Testing Equipments Especial 2M Integrating Sphere, Ipx6, Ik10, Humidity Chamber. Similar To Model No. Rigel Pt Clear Sl 30W Led 30K The Luminaire Should Be With A Valid Bis Number. , Supplying And Erecting Of Decorative Desing Bollard Of 0.6Mtr Height Decorative Bollard Made Of Steel Pipe Which Is Fabricated Using 114M Dia X 3.0Mm Thick. The Luminaire Should Be With High Pressure Die- Cast Thermal Management For Longer Life Of The Leds And The Ip65 Optical Compartment. The Diffuser Shall Be Optical Grade Clear Pc / Pmma Pipe. The System Ac Wattage Of The Luminaire Shall Be 9W (± 10%), Colour Rendering Index Cri /= 70 And Residual Flux Of 70% (L70) @ 50,000 Hours At Ta Of 25°C. Colour Temperature (Cct) Of 3000K. The Luminaire Shall Be Suitable For Operating Within Temperature Range From - 10°C To + 40°C. The Light Source Should Be (Make- Osram/Bridgelux/Nichia/Cree/Lumiled) With Macadam /= 5. The Luminaire Should Be Deigned To Operate At Any Voltage From 140V To 280V, With Power Factor ≥ 0.95 And Shall Be Provided With Optional Built In Over Voltage And Under Voltage Protection And Internal Surge Protection Of 4/4 Kv In Both Common & Differential Modes. The Bollard Shall Be Provided With Decorative Die Cast Aluminium Embellishment To Add Aesthetic On The Bollard As Shown In The Drawing. The Bollard Is To Be Provided With A Surface Mounting Suitable Base Plate Of 200Mm X 200Mm X And Suitable Thickness As Per Is Standards. The Decorative Base Embellisment Is Made Of Cast Aluminium Material With Minimum Dia Of The Base Is 155Mm & Height Is 120Mm. All Dimension Is Within +/- 5% Tolerance. The Base Plate Shall Be Hot Dip Galvanized. The Mounting Plate Shall Be Provided With Round Holes For Alignment Of The Bollard. Overall Outer Dimensions Of Bollard Shall Be Ø130Mm (±3%) And 600Mm (±3%) Height And The Shape Shall Be As Per The Sketch Attached Herewith. Similar To Model No. Ara Ø130Mm Bp 600H Clear 9W Led 30K. , Supplying And Erecting Of Swimming Pool Light 18W Dc Operated With Drivers And All Accessories Cct -3000K/ Rgb Ingress Protection-Ip 68 With Ss Housing, High Power Led To Be Operated On Dc, In Order To Keep The Area Safe And Shock Proof. , Supplying & Erecting Three Phase, 415V, Street Light Control Panel Up To The Max Load Of 6Kw, Tpn Mcb 40A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation, With Overcurrent, Short Circuit, Earth Fault Protection On Provided Iron Frame / Cement Concrete Foundation. , Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Tpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting And Marking Four Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 40A In Provided Distribution Board. , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Sp/Tp Mcbs Total 4 Ways /12 Poles, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Vertical Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 25 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rod Complete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity As 10 T/Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation, Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 3 To 5M Octagonal / Conical Gi Pole). , Making Cement Concrete Foundation In 1:3:6 Cement Concrete, (20 To 25) Mm.Stone Metal Duly Plastered With Necessary Curing For Complete. (Pole Muffing Or Any Other Purpose). , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm (30 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid Inprovided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying And Erecting Integrated Led Flood Light Fitting Max. 155W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 18600 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70B50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying And Erecting 12.5 M (Clear Height) Motorized High-Mast (Top -150Mm, Bottom- 360Mm) Hot Dipped Galvanized Material With Average Minimum Thickness 65 Micron, Made From High Tensile Structure Grade Steel As Per Bsen - 10025 S 355/E350 & 3Mm Thickness, With Base Plate 25 Mm Thick X Od 520 Mm Grade As Per Is-2062, Pole Made In Single Section & Submerge Annual Rate Contract Welded, With Lowering & Raising Motorized Unit, Wire Rope Stainless Steel 316 Grade 2 Nos., 7X19 Construction 5Mm, Sg-Dg U Clamps, Double Drum With Assembly 250 Kg, 5X2.5 Sq.Mm. Flexible Copper Cable With Lantern Carriage Assembly Suitable For Max. 12 Nos. Luminaires And Its Control Gear Box, Lightning Arrestor, Arrangement For Fixing Aviation Light, High-Mast With Serial Number, Factory Inspection Report/Test Report Of High-Mast Should Be Provided As Per Specifications On Provided Foundation J Type Stud/Bolts With Necessary Accessories Complete As Per Specification No. Ohpl/ Hm (Excluding Luminaries) , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For High-Mast Of The Same Manufacturer With 32A Tpn Mcb Incomer, 24Hr Astronomical Time Switch With Minimum 5 Years Battery Backup, Ip 54 And Ik10 Protection, 25 A Tp Contactor For Automatic Switching Of Luminaires, 2 No. 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Complete Erected In Min. 14 Swg Crca Sheet Box With Supporting Angles, Self Lock, Gasket And Slanting Top Erected On Cement Concrete Foundation Complete. , Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Making M- 20 Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq. M At 2 M Depth Including Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 12.5 M Raising Lowering High Mast).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
36.
Power #10830208 Price Bid
Erection Testing And Commissioning Of 33 Kv 400 Sqmm Ug Cable By Microtunnelling Process With Its Associated Work For Two Nos Feeder Bay From Dharma Gss To Rangamati Substation Under Ipds Under Midnapur Division , Laying Of 25 Sqmm Coper Control Cable ( 4/8/12 ) Core ( Rate To Be Quoted Excluding Gst ) , I ) 4 Core Control Cable , Ii ) 8 Core Control Cable , Iii ) 12 Core Control Cable , Instalation Of 33 Kv Indoor Type , Scada Compatible Control And Relay Pannel For Indivisual Control Of Feeder On Concrete Floor By Grouting 75*40*6 Mm Gi Channel And Cutting Of Concrete Base In Control Room ( G . I . Channel Will Be Supplied By Contractor ) Including Necessary Connection With Relay , Metering / Measuring Equipment Etc . With Supply And Fixing Of Gland , Ferrules , Pvc Tape And Sokets Etc , ( Rate To Be Quoted Excluding Gst ) , Installation Of 33 Kv Ct ( 400-200/1-1 ) With Supply Of G . I . Structure Including Necessary Connection With Relay , Metering / Measuring Equipment Etc . With Supply And Fixing Of Gland , Ferrules , Pvc Tape And Sokets Etc ( 1Set=3 Nos ) ( Rate To Be Quoted Excluding Gst ) , Installation Of 33 Kv Ct ( 400-200/1-1 ) On Existing G . I . Structure Including Necessary Connection With Relay , Metering / Measuring Equipment Etc . With Supply And Fixing Of Gland , Ferrules , Pvc Tape And Sokets Etc ( 1Set=3 Nos ) ( Rate To Be Quoted Excluding Gst ) , Installation Of 33 Kv Outdoor Vcb With Supply Of G . I . Structure Including Necessary Connection With Relay , Metering / Measuring Equipment Etc . With Supply And Fixing Of Gland , Ferrules , Pvc Tape And Sokets Etc ( Rate To Be Quoted Excluding Gst ) , Installation Of 33 Kv Pt On Existing G . I . Structure Including Necessary Connection With Relay , Metering / Measuring Equipment Etc . With Supply And Fixing Of Gland , Ferrules , Pvc Tape And Sokets Etc , Painting Of All Ptr ( 4Nos ) , Sst ( 1 Nos ) , Ct ( 8 Set ) , Pt ( 2 Set ) , Vcb ( 8 Set ) Foundation ( Old+New ) With Ct , Pt , Vcb Structure Aluminium Painting , Phase Marking Etc . ( Rate To Be Quoted Excluding Gst ) , Survey Of 33 Kv Cable Laying Work ( Rate To Be Quoted Excluding Gst ) , Supply And Fixing Of Of 150 Mm . Dia Tata Medium Gi Pipe As Per I . S . I . ( Rate To Be Quoted Excluding Gst ) , Erec . Of 42 Kv . Class Gapless La With Structure ( Rate To Be Quoted Excluding Gst ) , Making & Fix . Of Cable Raiser ( Iron Materials To Be Supplied By Wbsedcl ) ( Rate To Be Quoted Excluding Gst ) , Exacavation Of Soil By Cutting Rocky Soil ( Rate To Be Quoted Excluding Gst ) , Microtunnelling Work ( 3 M Depth ) With Supply And Laying Of 160 Mm Hdpe Pipe ( Rate To Be Quoted Excluding Gst ) , Supply Of Bricks ( Rate To Be Quoted Excluding Gst ) , Laying Of Bricks ( Rate To Be Quoted Excluding Gst ) , Supply And Erection Of Cast Iron Cable Marker On Concrete Foundation Blocks For Straight Run , Road Crossing , Joint Lacation Etc As Per Drawing No . Pln ( D ) /Ss/128 Dated 23 . 06 . 2018 & Specification & Direction Of Site Engineer ( Rate To Be Quoted Excluding Gst ) , Laying Of 33 Kv 400 Sq . Mm . 3C Xlpe Cable Through 160 Mm Hdpe Pipe Including Loop And Riser ( Rate To Be Quoted Excluding Gst ) , Supply And Fixing Of 33 Kv 400 Sqmm Straight Through Jointing Kit ( Brand 3M/ Raychem ) Including Making Of Jointing Pit ( Rate To Be Quoted Excluding Gst ) , Supply And Fixing Of 33 Kv 400 Sqmm Outdoor Jointing Kit ( Brand 3M/ Raychem ) Including Fixing Of Jointing Box At Existing Structure ( Rate To Be Quoted Excluding Gst ) , Pipe Earthing With Supply Of 50X6 Mm G . I . Flat And 40 Mm Dia Perforated G . I . Pipe Including Making Of Pit With Salt , Sand And Charcoal Treatment And Pit To Be Covered With Concrete Slab And Brick Work With Connection Complete . ( Jointing Of G . I . Flat To Be Done Both With Welding And Nut-Bolt ) . All Welded Portion To Be Painted With Bituminous Paint ( Rate To Be Quoted Excluding Gst ) , Making Of Protection Duct For 33 Kv Cable Joint ( Rate To Be Quoted Excluding Gst )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
37.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
38.
Public Administrative Department #10800954 AOC
Renovation As Per Requirement And Related Electrical Works In Various Gardens Under A Zone Office (2025-26)-Providing and erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing and recording the results as per specification no. EA-EP Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. Supplying, erecting and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands and lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying including excavation of suitable width and depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. Repairing of 120W LED Street Light fi ng with replacing of electronic type Driver 120 w for Outdoor LED Fi ngs with 1 year Warranty. Repairing of 100W LED Street Light fi ng with replacing of electronic type Driver 100 w for Outdoor LED Fi ngs with 1 year Warranty. Repairing of 100W LED Street Light fi ng with replacing of compa ble MCPCB with LED lumens of minimum 150 lumens/wa , CRI 􀀁75 and white light 4500-5700K with 1 year Warranty of MCPCB.(With Proper lens and Suitable For all makes) Dismantling the existing W.T. fluorescent Fitting S.V./M.V./M.H. lamp/ LED fitting from pole with bracket complete. Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as perdesign complete (for 3 to 5m octagonal / conical GI pole). Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW Supply of decorative post top pole 4 Mtrs long made from MS pipe of grade IS1239. The bottom section of pole shall be 139.7mmx4.50mm x 1000mm, and top shall be 76. 1mm x 3.25mm x 3000 mm. The pole shall have base plate of 250x250x10mm. Bottom and top pipe of the pole shall be provided with cast iron emblishment to add asthetics on the pole with the help of grub screw. The pole shall have weather proof inbuilt junction box with flush door and locking arrangements. Junction box shall be provided with 6Amp MCB, Backlit sheet and heavy duty connector. The pole shall be provided with suitable earthing arrangements. The pole shall be provided with 4Nos foundation bolts of M16x600mm with washer and nuts. The body of the pole shall be polished throughly to give smooth surface and pre treated and painted with epoxy primer and finished with UV Ray resistant PU paint in approved colour shade. SITC of Post Top Luminarie LED 3000K,<(>,<)> 240Vac CRI >80 Input power : 45W Dimension : 445 x 741 mm Light Distribu on 360° Electronic driver ON/OFF CE and BIS LUMINAIRE TYPE Light Column. IP ra ng IP65 MATERIAL CHARACTERISTICS Die cast aluminium top cover 445 mm, die cast aluminium decora ve knob on top, Gravity die cast aluminium (LM6 Grade) suppor ng arm integrated with die-cast aluminium base (LM6 Grade) suitable for moun ng Ø60mm OD pipe. SS fasteners. Pure polyester powder coated process : Acid treatment and pure polyester powder coa ng. LIGHTING PERFORMANCE Translucent acrylic diffuser of 2.7mm thickness with controlled downward light emission. Lamp fixed posi on. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the exis ng regula ons of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Opera ng ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, Cut off Range 440v,THD <(><<)>10%, Internal Surge protec on 6KV.External Surge Protec on 10KV. ( With 5 Years Warantee ) Opera ng Tempreture -15 Degree Tp +50 Degree and L ED Lumens 150 Lumens/Wa Supplying and installing street light feeder pillar as switching point, as per approved drawing, made from 14 SWG MS sheet of size 1.2x0.9x0.45 mtr with slanted Roof and minimum 2 Louvers on side walls, Front Single Door ( Flush / surface finish type) hinged (3 Nos) from inside with Double folded 14 SWG MS Sheet with rubber gasket on the touching face of edge. The Feeder Piller shall consist of following accessories and provisions, wired up with 16 sq.mm Copper stranded single core PVC insulated wire forpower wiring and 1.5 sq.mm single core PVC insulated copper wire for control wiring. Earthing connection stud provision on both side faces. complete as per specification. 1) 3 Nos. --- Single pole contactors 40 amp capacity of approved make, 2) 1 No. ---- digital time switch of LT/GIC or similar type as ASTRO Mini with min 1 NO contact of 7 Amp, 230 V capacity, 3) 1 No ---- MCB Version 3 pole Isolator switch 500 V 63 amp.capacity, 4) 1 No --- .Alluminium busbar of 25x4 mm, 0.3 mtr long resting on 2 nos. porcelain panel insulator/Busbar supports for Neutral Connection. 5) 1 No ---- 3 pin 6 Amp Plug socket and switch combined unit, 6) No --- Point wiring for Lamp point, with angle holder and switch on board, 7) 3 Nos. ---- 100 Amps Kit-kat Fuse annealed Copper Contacts for incoming supply. 8) 6 Nos --- 32 Amps single pole MCB mounted on D-rail for outgoing circuits. 9) 2 Nos --- Self locking arrangements with keys. 10) 2 Nos --- Earthing connection studs on both side wall minimum of M8 nut bolt. All above accessories are to be installed on Commercial Plywood of 19 mm Thick Having size1.0 x 0.8 m resting on 6 nos of supports welded on MS Sheet. Sufficient space/provision for installation of MSEDCL power Meter shall be kept. The feedar Piller shall be installed on MS Angle/iron frame fabricated from IS-MC-75- 50X50X5 mm Angle having size 0.9 (B) x 0.45 (W) x 1.2 (H) Mtr with holepass angles etc. Additional MS Sheet of size 0.9x0.45 mtr shall be welded at front and back of frame to hide the cable entries. The frame shall be grouted in earth with necessary Cement Concrete Filling including excavation in all type of strata. The MS Sheet and MS angle iron frame shall be completely painted from inside and outside with one coat of red oxide and 2 coats of ivory/red enamelled paints. The coat of bituminous paint shall be applied for portion of frame grouted in earth. The Danger Board shall be revetted at front door.(RA Item 28-4-1 (18-19) SITC of Flexible strip light with 5m meter length, Protection Rating: IP20, Power consumption: 15W/m, CCT: 5000K, (as per the design approval) Beam Angle: 120°, Power Input: DC 12V/24V with external driver, Surge Protection: Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Fixture will be suitable to operate in temperature range of 0°C to 50°C LED life time should be at least 50 ,000 burning hours at L.70 at 25 degree centigrade. Luminaire is inclusive of driver and Integral male/female connectors with structures in pre wired conditions as per IS standard. LED Makes should be CREE, LumilLED, Osram, Seoul, Epistar, Nichia or equivalent. with 5 Years of onsite warantee. SITC of BIS registered LED blue color architectural spot lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish. Luminaire offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Wattage should be 9W(±5%). Surge Protection 2 KV-4 KV.Fixture should have constant locking hinges for simple position control from various angles without special tools. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaireshall be IP66 and IK08 rated. LED Life time shall be at least 50,000 burning hours at 50°C. LED should be of make Nichea, Osram, Cree, Lumiled. Luminaire shall be complete with integrated IP 66/67 potted driver and capable of operating at line voltage fro m 100-240 Vac, 50Hz with power factor > 0.9. The product should be BIS approved with R number mentioned on product label. Fixture should have power cable of minimum 600mm length. To be supported with Product test reports BIS, CE ROHS should he submited. IP66, IK08. LM79 and LM80 reports form NABL Accredited laboratory should submited priorto the supply of material. The Fitting includes all inbuilt accessories, connectors, wire etc. complete in all respect with 5 Years of onsite warantee. SITC of 50W LED RGBWW having BIS standard IS 10322 (Part 5/Sec 1): 2012 and having CE certification against standard Low Voltage Directive and Protective Equipment - EN 60598-1:2015, and Electromagnetic Compatibility Directive - EN 61547: 2009. BISregi stered LED RGBWW architectural wash lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, embossed manufacturer logo, Seperate compartment for keeping the decoder/driver in the housing. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Power input of wattage 50W(±5%). Hot spot and light distribution Optics Designed to minimize hot spots and fringing in color mixing applications. Surge Protection 2 KV - 4 KV Additional if required will be added as per the requirement). Luminaire offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have constant locking hinges for simple position control from various angles without special tools. Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK08 rated. LED Life time shall be at least 50,000 burning hours at 50°C. ED should be of make Nichea, Osram, Cree, Lu miled. DMX enabler circuit should be inside the Luminaire only Luminaire shall be with remote driver with output voltage 24V DC.The product should be BIS approved with number mentioned on product label. Fixture should have power cable of minimum 600mm length and signal loop in-out cable of minimum 600mm with IP68 male-female connectors.To be supported with Product test reports BIS, CE RoHS should be submited. IP66, IK08, LM79 and LM80 reports form NABL Accredited laboratory should submited priorto the supply of material. The Fitting includes all inbuilt accessories, connectors, wire etc. complete in all respect with 5 Years of onsite warantee. Repairing of 60W LED Street Light fiti ng with replacing of electronic type Driver 60 w for Outdoor LED Fi ngs with 1 year Warranty. Repairing of 135W LED Street Light fiting with replacing of compa ble MCPCB with LED lumens of minimum 150 lumens/wa , CRI 􀀁75 and white light 4500-5700K with 1 year Warranty of MCPCB.(With Proper lens and Suitable For all makes) Repairing of 60W LED Street Light fi ng with replacing of compa ble MCPCB with LED lumens of minimum 150 lumens/wa , CRI 􀀁75 and white light 4500-5700K with 1 year Warranty of MCPCB.(With Proper lens and Suitable For all makes)
Contract Date: Mar 09, 2026 Contract Value : 21.17 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
39.
Drinking Water Supply and Sanitation #10787620 Price Bid
Tender For Renovation Of Lighting/Electrification System Of Ias Bungalow And Hasanpur Reservoir Ndmc Area, Djb; 1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a)3 x 2.5 sqmm 2 (b) 3 x 4 sqmm 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required.2 x 10 + 1 x 6 sqmmearth wire. 4 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( Group B ) 5 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable with 1.5 sqmm FRLS PVC insulated copper conductor single core cable with earth wirein the existing surface/recessed steel/PVC conduit including dismantling as required. 6 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door( L&T/Siemens/Hagger and DJB approved make ) 7 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole ( L&T/Siemens/Hagger and DJB approved make ) 8 Supplying and fixing following 63 amp, double pole, 240 volts, DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.(L&T/Siemens/Hagger and DJB approved make ) 9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 amps switch 10 (b) 3 pin 5/6 amp socket outlet 11 (c) 15/16 amps switch 12 (d) 6 pin 15/16 amp socket outlet 13 Supplying and fixing the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as required.6 module ( 200mm x 75 mm ) 14 Supplying andfixing of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connection etc 15 Supplying and fixing of brass batten/angle holder including connections etc as required 16 Supplying and fixingstepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 17 Supplying and fixing of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20mm 18 (b) 25 mm 19 Supplying of 48 ( 1200 mm ) ceiling fan with all accessories and making connection etc as reqd. at site ( Havells/ CG / Orient/DJB approved ) 20 Supplying of 36 watt Higher Wattage Decorative ultra slim aluminum LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. ( Make : Crompton/Havells/DJB approved ) 21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE alumium conductor cable of 1.1 KV grade as required 4 x 16 sq. mm ( 28 mm ) 22 New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. 120 watt 23 Installation of LED light 120 Watts on street light Pole after erection with all safety measures with the help of skilled labour/technician as required. 24 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 25 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1.KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm 26 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar 27 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 28 Supplying and fixingof 65 mm dia G.Istreet light pole , 4.5 mtr long approx heavy duty complete with 65/32 reducer including1 x 1 G.I base plateetc. as reqd.at site 29 Erection of G.I pole of length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre 30 Supplying and fixing of 32 mm dia X 1.80 metres long G.I. pipe(medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to therequired shape, 1 nos 40 mm X 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finishpaint etc. This also include supply & fixing of 2 Nos,32 mm dia X 1.80 metres long G.I. pipe with bend for junction box. 31 Supply of SMC junction boxes anti-corrosive water resistant, UV protected, High temp resistant, weatherable and suitable for all kinds of climatic conditions. Self-colour fire retardant and high dielectric strength maintenance free. Make: Bajaj / Hensel / Syntex/Other DJB approved make 32 Installation of junction boxes on the each pole with the help of clamps, nut & bolts etc. The junction boxes should have Mini SP C-series MCB of 6 A 33 Supply of XLPE insulated, PVC sheathed Al. conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 4C x 25 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved. 34 Supply of XLPE insulated, PVC sheathed Al. conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 4C x 16 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved. 35 Supply of XLPE insulated, PVC sheathed Al. conductor Armoured cable for working voltage upto 1.1 KV conforming to IS 7098/1988 of following sizes 3 x 6 SQ mm Make: Gloster/Grandlay/UNIVERSAL/HAVELLS/ Polycab/DJB approved. 36 Painting of street light poles with Primer and 2 Coats of High gloss Enamel Paint. Make:- Asian/Berger/Nerolac. 37 Supplying of100 watt flood light fittingpressured dia cast housing with IP65 protection efficient high 220-240V output emitter LED for better distribution with dimension 447 X 163 x 327 mmand 6500 colour with lumens 15500 with all accessoires etc as etc as reqd. at site.( Make : Crompton/Havells/DJB approved ) 38 Installation of LED light flood light 100 Wattswith all safety measures with the help of skilled labour/technician as required. 39 Supplying and fixing of angle frame of suitable size ( 50 x 50 ) including excavation and repairing the same etc as reqd. at site. 40 Supplying ,installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply power supply connections Incomer -200 amp MCCB 36 KA– 1 No., outcomer - 100 amp - 3 nos 36 KA , TPN Amp - 3 nos DP MCB-6 No. , 3 No’s indicating LED fittings with 6 amp SP MCBs - 10 nos etc as required 41 Supplyingand laying of 40 mm HDPE flexible PVC pipe complete with all accessories i/c jointing and making good the same etc as reqd. at site 42 Installation of ceiling fanwith all safety measures with the help of skilled labour/technician as required. 43 Supplyingand laying of 2 x 2 PVC Heavy duty box complete with all accessories i/c jointing and making good the same etc as reqd. at site( Syntex make ) 44 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required for 2 runs. 45 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. as required. 46 Providing and laying earth connectionFRL Som earth electrode with 6 SWG dia G.I wire in 15 mm G.I Pipe FRL som earth electrode including connection with G.I thimble excavationand refilling as required. 47 Loading, unloading, cartage and transportation charges for the abovepole upto the side i/c charges of heavy labour etc. as per site requirement. 48 Testing and commission of complete work in the presence of Engineer-in-charge with full satisfaction.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
40.
Power #10784354 Price Bid
Deposit Works In The Area Of Edsd Laxminagar Under Edd-Laxminagar, Mathura - Carrying out the following works under deposit head upto the execution/completion and commissioning of works. Carriage of 8.5/9 Mtr Long PCC Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 11/13 Mtr Long ST Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 16 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 25 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 63/100 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 250 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 11 KV XLPE Cable size 3x70/3x120 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of 11 KV XLPE Cable size 3x185/3x300 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel and other required material from Store Center at 132 KV substation Mathura to the site of work including loading and unloading of material at both ends. Erection of single pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of single pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Installation of stay set with grouting and nuzzling etc. as per RESPO drawing along with all routine material to be used for such works. Earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour T&P and required material for such work. Laying, sagging stringing and binding of ACSR Weasel Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of ACSR Dog Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of Arial Bunch Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of LT PVC Cable on the erected PCC pole/STP including jumpering as per RESPO manual. Laying of 11 KV XLPE Cable size 3x70/3x120 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Laying of 11 KV XLPE Cable size 3x185/3x300 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*70/3*120 as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*185/3*300 as per direction of supervising engineer. Chopping of Tree branches to Clear the route properly. Mounting of 16 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 25 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 63/100 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 250 KVA Transformer on the Double pole/Plinth structures and connections thereof. Cutting of CC Road for making depth foundation for erection of pole. Installation of 11 KV CT/PT Combined metering unit on existing double pole structure of large & heavy, power consumers to avoid possibility of theft of energy & 11 KV feeders at 33/11 KV sub- station including the cost of accessories (Nut & Bolt, PVC Tape etc.) required for proper completion of work also provided by the contractor. (including carriage of New 11 KV CT/PT combined metering unit from Store Center Mathura to Site of work.) Fixing of meter pilfer box (service connection meter holding capacity). Work including grouting of meter pillar box in ratio 1:4:8 cement, sand and brick ballast as per standard norms by providing all material. Grouting of PCC/ST pole in ratio 1:4:8 cement, sand and brick ballast as per standard norms, including cost of all grouting material. Guarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. It includes the cost o f labour T&P carriage etc required for proper completion. Providing & Fixing of three phase Distribution Box on erected Pole. Fixing of three phase Distribution Box on erected Pole. Chemical earthing (Neutral/Body) including all required material & work as per Respo norms. Laying of overhead 11 KV XLPE 3x70 mm2/3x120 mm2 as per direction of supervising engineer. Laying of overhead 11 KV XLPE 3x185 mm2/3x300 mm2 as per direction of supervising engineer. Constructions of transformer plinth of size 5.5x5.5x6 feet, with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x1650mm) and plaster. All material shall be provided by the contractor. Old good conditioned bricks, stronegrit and MS bar/MS channel etc will be used after approval of Supervisory Engineer to lower the cost of work. Work includes Removal of T/F from old plinth and re-energize the T/F on earth safely till new plinth construction. Then after remounting the T/F on newly constructed plinth and making all connections to energize the T/F. Providing and fixing of welded wire mesh fencing around transformer plinth with MS Angle of size 40x40x6 mm length and 1.20 mtrs height. Such panels shall be supported on MS angle from of size 40x40x6 mm having 04 nos corner supports of height 1.65 mtrs including extended legs for grouting which will be used as a door for entry of the personnel or removal/shifting of transformer with welded hinges, sliding belt etc for locking arrangement as per drawing and specifications. The fencing will be painted in the green colour synthetic enamel paint after painting with one coat of red oxide primer. The rates should be inclusive of all materials required for completion of above work. (Length of each fencing approx. 11 mtrs) with T& P labour etc. The contractor shall provide F clamps, D/P clamps, stay clapms, cross arm clamps, LT clamps, ABC clamps, suspension clamps, piercing connectors, I-hooks, dead end clamps, any other clamps, nut & bolts and shackle insulators without charging any extra cost, in case the same are not available in the stores. Contractor shall also provide/perform any contingent material/work at his own cost, which is not included in the boq/estimates but is required for execution/completion of the work. Further, any fabrication work, if required, shall also be carried out by the contractor at his own cost, for which no additional payment shall be admissible.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
41.
Power #10784350 Price Bid
Tender For Deposit work in the area of EDSD Raya under EDD-Laxminagar, Mathura - Carrying out the following works under deposit head upto the execution/completion and commissioning of works. Carriage of 8.5/9 Mtr Long PCC Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 11/13 Mtr Long ST Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 16 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 25 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 63/100 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 250 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 11 KV XLPE Cable size 3x70/3x120 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of 11 KV XLPE Cable size 3x185/3x300 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel and other required material from Store Center at 132 KV substation Mathura to the site of work including loading and unloading of material at both ends. Erection of single pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of single pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Installation of stay set with grouting and nuzzling etc. as per RESPO drawing along with all routine material to be used for such works. Earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour T&P and required material for such work. Laying, sagging stringing and binding of ACSR Weasel Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of ACSR Dog Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of Arial Bunch Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of LT PVC Cable on the erected PCC pole/STP including jumpering as per RESPO manual. Laying of 11 KV XLPE Cable size 3x70/3x120 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Laying of 11 KV XLPE Cable size 3x185/3x300 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*70/3*120 as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*185/3*300 as per direction of supervising engineer. Chopping of Tree branches to Clear the route properly. Mounting of 16 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 25 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 63/100 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 250 KVA Transformer on the Double pole/Plinth structures and connections thereof. Cutting of CC Road for making depth foundation for erection of pole. Installation of 11 KV CT/PT Combined metering unit on existing double pole structure of large & heavy, power consumers to avoid possibility of theft of energy & 11 KV feeders at 33/11 KV sub- station including the cost of accessories (Nut & Bolt, PVC Tape etc.) required for proper completion of work also provided by the contractor. (including carriage of New 11 KV CT/PT combined metering unit from Store Center Mathura to Site of work.) Fixing of meter pilfer box (service connection meter holding capacity). Work including grouting of meter pillar box in ratio 1:4:8 cement, sand and brick ballast as per standard norms by providing all material. Grouting of PCC/ST pole in ratio 1:4:8 cement, sand and brick ballast as per standard norms, including cost of all grouting material. Guarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. It includes the cost o f labour T&P carriage etc required for proper completion. Providing & Fixing of three phase Distribution Box on erected Pole. Fixing of three phase Distribution Box on erected Pole. Chemical earthing (Neutral/Body) including all required material & work as per Respo norms. Laying of overhead 11 KV XLPE 3x70 mm2/3x120 mm2 as per direction of supervising engineer. Laying of overhead 11 KV XLPE 3x185 mm2/3x300 mm2 as per direction of supervising engineer. Constructions of transformer plinth of size 5.5x5.5x6 feet, with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x1650mm) and plaster. All material shall be provided by the contractor. Old good conditioned bricks, stronegrit and MS bar/MS channel etc will be used after approval of Supervisory Engineer to lower the cost of work. Work includes Removal of T/F from old plinth and re-energize the T/F on earth safely till new plinth construction. Then after remounting the T/F on newly constructed plinth and making all connections to energize the T/F. Providing and fixing of welded wire mesh fencing around transformer plinth with MS Angle of size 40x40x6 mm length and 1.20 mtrs height. Such panels shall be supported on MS angle from of size 40x40x6 mm having 04 nos corner supports of height 1.65 mtrs including extended legs for grouting which will be used as a door for entry of the personnel or removal/shifting of transformer with welded hinges, sliding belt etc for locking arrangement as per drawing and specifications. The fencing will be painted in the green colour synthetic enamel paint after painting with one coat of red oxide primer. The rates should be inclusive of all materials required for completion of above work. (Length of each fencing approx. 11 mtrs) with T& P labour etc. The contractor shall provide F clamps, D/P clamps, stay clapms, cross arm clamps, LT clamps, ABC clamps, suspension clamps, piercing connectors, I-hooks, dead end clamps, any other clamps, nut & bolts and shackle insulators without charging any extra cost. Contractor shall also provide/perform any contingent material/work at his own cost, which is not included in the boq/estimates but is required for execution/completion of the work. Further, any fabrication work, if required, shall also be carried out by the contractor at his own cost, for which no additional payment shall be admissible.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
42.
Power #10784349 Price Bid
Deposit Works In The Area Of Edsd Mant Under Edd-Mant, Mathura - Carrying out the following works under deposit head upto the execution/completion and commissioning of works. Carriage of 8.5/9 Mtr Long PCC Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 11/13 Mtr Long ST Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 16 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 25 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 63/100 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 250 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 11 KV XLPE Cable size 3x70/3x120 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of 11 KV XLPE Cable size 3x185/3x300 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel and other required material from Store Center at 132 KV substation Mathura to the site of work including loading and unloading of material at both ends. Erection of single pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of single pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Installation of stay set with grouting and nuzzling etc. as per RESPO drawing along with all routine material to be used for such works. Earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour T&P and required material for such work. Laying, sagging stringing and binding of ACSR Weasel Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of ACSR Dog Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of Arial Bunch Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of LT PVC Cable on the erected PCC pole/STP including jumpering as per RESPO manual. Laying of 11 KV XLPE Cable size 3x70/3x120 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Laying of 11 KV XLPE Cable size 3x185/3x300 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*70/3*120 as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*185/3*300 as per direction of supervising engineer. Chopping of Tree branches to Clear the route properly. Mounting of 16 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 25 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 63/100 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 250 KVA Transformer on the Double pole/Plinth structures and connections thereof. Cutting of CC Road for making depth foundation for erection of pole. Installation of 11 KV CT/PT Combined metering unit on existing double pole structure of large & heavy, power consumers to avoid possibility of theft of energy & 11 KV feeders at 33/11 KV sub- station including the cost of accessories (Nut & Bolt, PVC Tape etc.) required for proper completion of work also provided by the contractor. (including carriage of New 11 KV CT/PT combined metering unit from Store Center Mathura to Site of work.) Fixing of meter pilfer box (service connection meter holding capacity). Work including grouting of meter pillar box in ratio 1:4:8 cement, sand and brick ballast as per standard norms by providing all material. Grouting of PCC/ST pole in ratio 1:4:8 cement, sand and brick ballast as per standard norms, including cost of all grouting material. Guarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. It includes the cost o f labour T&P carriage etc required for proper completion. Providing & Fixing of three phase Distribution Box on erected Pole. Fixing of three phase Distribution Box on erected Pole. Chemical earthing (Neutral/Body) including all required material & work as per Respo norms. Laying of overhead 11 KV XLPE 3x70 mm2/3x120 mm2 as per direction of supervising engineer. Laying of overhead 11 KV XLPE 3x185 mm2/3x300 mm2 as per direction of supervising engineer. Constructions of transformer plinth of size 5.5x5.5x6 feet, with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x1650mm) and plaster. All material shall be provided by the contractor. Old good conditioned bricks, stronegrit and MS bar/MS channel etc will be used after approval of Supervisory Engineer to lower the cost of work. Work includes Removal of T/F from old plinth and re-energize the T/F on earth safely till new plinth construction. Then after remounting the T/F on newly constructed plinth and making all connections to energize the T/F. Providing and fixing of welded wire mesh fencing around transformer plinth with MS Angle of size 40x40x6 mm length and 1.20 mtrs height. Such panels shall be supported on MS angle from of size 40x40x6 mm having 04 nos corner supports of height 1.65 mtrs including extended legs for grouting which will be used as a door for entry of the personnel or removal/shifting of transformer with welded hinges, sliding belt etc for locking arrangement as per drawing and specifications. The fencing will be painted in the green colour synthetic enamel paint after painting with one coat of red oxide primer. The rates should be inclusive of all materials required for completion of above work. (Length of each fencing approx. 11 mtrs) with T& P labour etc. The contractor shall provide F clamps, D/P clamps, stay clapms, cross arm clamps, LT clamps, ABC clamps, suspension clamps, piercing connectors, I-hooks, dead end clamps, any other clamps, nut & bolts and shackle insulators without charging any extra cost, in case the same are not available in the stores. Contractor shall also provide/perform any contingent material/work at his own cost, which is not included in the boq/estimates but is required for execution/completion of the work. Further, any fabrication work, if required, shall also be carried out by the contractor at his own cost, for which no additional payment shall be admissible.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
43.
Power #10784347 Price Bid
Tender For Deposit Works In The Area Of Edsd Naujheel Under Edd-Mant, Mathura - Carrying out the following works under deposit head upto the execution/completion and commissioning of works. Carriage of 8.5/9 Mtr Long PCC Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 11/13 Mtr Long ST Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.) Carriage of 16 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 25 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 63/100 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 250 KVA Transformer from Store Centre, Mathura to pit site with loading & unloading at both ends Carriage of 11 KV XLPE Cable size 3x70/3x120 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of 11 KV XLPE Cable size 3x185/3x300 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. Carriage of Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel and other required material from Store Center at 132 KV substation Mathura to the site of work including loading and unloading of material at both ends. Erection of single pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of single pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 8.5/9 Mtrs on PCC Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Erection of Double pole structure 11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms. Installation of stay set with grouting and nuzzling etc. as per RESPO drawing along with all routine material to be used for such works. Earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour T&P and required material for such work. Laying, sagging stringing and binding of ACSR Weasel Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of ACSR Dog Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of Arial Bunch Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. Laying, sagging stringing and binding of LT PVC Cable on the erected PCC pole/STP including jumpering as per RESPO manual. Laying of 11 KV XLPE Cable size 3x70/3x120 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Laying of 11 KV XLPE Cable size 3x185/3x300 sq.mm. in the trench/G.I pipe/HDPE pipe and re-dressing of trench after laying of XLPE Cable for proper completion of work as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*70/3*120 as per direction of supervising engineer. Providing & fixing/filling jointing kits O/D, I/D suitable for cable size 3*185/3*300 as per direction of supervising engineer. Chopping of Tree branches to Clear the route properly. Mounting of 16 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 25 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 63/100 KVA Transformer on the Double pole/Plinth structures and connections thereof. Mounting of 250 KVA Transformer on the Double pole/Plinth structures and connections thereof. Cutting of CC Road for making depth foundation for erection of pole. Installation of 11 KV CT/PT Combined metering unit on existing double pole structure of large & heavy, power consumers to avoid possibility of theft of energy & 11 KV feeders at 33/11 KV sub- station including the cost of accessories (Nut & Bolt, PVC Tape etc.) required for proper completion of work also provided by the contractor. (including carriage of New 11 KV CT/PT combined metering unit from Store Center Mathura to Site of work.) Fixing of meter pilfer box (service connection meter holding capacity). Work including grouting of meter pillar box in ratio 1:4:8 cement, sand and brick ballast as per standard norms by providing all material. Grouting of PCC/ST pole in ratio 1:4:8 cement, sand and brick ballast as per standard norms, including cost of all grouting material. Guarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. It includes the cost o f labour T&P carriage etc required for proper completion. Providing & Fixing of three phase Distribution Box on erected Pole. Fixing of three phase Distribution Box on erected Pole. Chemical earthing (Neutral/Body) including all required material & work as per Respo norms. Laying of overhead 11 KV XLPE 3x70 mm2/3x120 mm2 as per direction of supervising engineer. Laying of overhead 11 KV XLPE 3x185 mm2/3x300 mm2 as per direction of supervising engineer. Constructions of transformer plinth of size 5.5x5.5x6 feet, with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x1650mm) and plaster. All material shall be provided by the contractor. Old good conditioned bricks, stronegrit and MS bar/MS channel etc will be used after approval of Supervisory Engineer to lower the cost of work. Work includes Removal of T/F from old plinth and re-energize the T/F on earth safely till new plinth construction. Then after remounting the T/F on newly constructed plinth and making all connections to energize the T/F. Providing and fixing of welded wire mesh fencing around transformer plinth with MS Angle of size 40x40x6 mm length and 1.20 mtrs height. Such panels shall be supported on MS angle from of size 40x40x6 mm having 04 nos corner supports of height 1.65 mtrs including extended legs for grouting which will be used as a door for entry of the personnel or removal/shifting of transformer with welded hinges, sliding belt etc for locking arrangement as per drawing and specifications. The fencing will be painted in the green colour synthetic enamel paint after painting with one coat of red oxide primer. The rates should be inclusive of all materials required for completion of above work. (Length of each fencing approx. 11 mtrs) with T& P labour etc. The contractor shall provide F clamps, D/P clamps, stay clapms, cross arm clamps, LT clamps, ABC clamps, suspension clamps, piercing connectors, I-hooks, dead end clamps, any other clamps, nut & bolts and shackle insulators without charging any extra cost, in case the same are not available in the stores. Contractor shall also provide/perform any contingent material/work at his own cost, which is not included in the boq/estimates but is required for execution/completion of the work. Further, any fabrication work, if required, shall also be carried out by the contractor at his own cost, for which no additional payment shall be admissible.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
44.
Rural Development #10780316 Price Bid
Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Nighoje Tal Khed Dist Pune- 1 Supplying and erecting modulartype switch6A / 10A 2 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length 3 Providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2) 4 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.OH-PL/STP 5 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in 6 Supplying and erectingLED street light fitting suitable for 36w TO 40w LED Street Light, including lamp, with PF > 0.95 class IP 65 . 7 Supplying and erecting LED street light fitting suitable for 50W lamp, including lamp, with PF > 0.95 class IP 65. 8 Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65. 9 Supplying and erectingLED street light fitting suitable for 90 w LED Street Light, including lamp, with PF > 0.95 class IP 65. 10 Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 11 Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 12 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 13 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 14 Labour Chrages for LED fitting on Street light or MS light pole. 15 Dismentaling Charges -LED street light of pole. 16 1.25 mm CRCA sheet metal enclosures box for Timmer and MCB 17 Supplying PVC insulated PVC round sheathed 1.5 sq.mm 18 Supplying & Laying armoured cable 4C X 6 Sq.mm. 19 Supplying & Laying armoured cable 4C X10 sq mm 20 Supplying & Layingarmoured cable 2C X 10 sq mm 21 Supplying & Layingarmoured cable 4C X 16 sq mm 22 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 23 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 24 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 25 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 26 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 27 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 28 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole. 29 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 30 Supplying and erecting mains with ISI mark WP2 x 2.5 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 31 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 32 25 Amp, 32 Amp Three Phase L/T Contactor 33 2.5 Sq. mm Multistand Copper Wire 34 Insulation Tape 35 Water Proof Tape 36 Street Light Pole Box FRP 37 Cement Street Light Pole Clamp 38 M.S. Street Light Pole Clamp 39 LED Street light Arm bend pipe 40 Small Size FRP box for MCB 41 Big Size FRP box for MCB 42 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 43 Servicing And Primary Maintenance For Street Light Pole. 44 Light Poles painting in Silver Colour 45 26W LED Light To 100W LED Light Repairing 46 Old Pole Shifting, Rework and Foundation Work per Pole etc. 47 Supply &Fixing of Shakle Hardware with Nut Bolt 48 Supply and Installation of Mini Feeder Pillar with Stand 49 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 50 Tree Triming for Overhead Line 51 Tree Triming for Overhead Line 52 7-1-33 Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor 53 7-1-31 Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm aluminium conductor 54 7-1-34Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm aluminium conductor 55 7-1-35 Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm aluminium conductor 56 5-3-5 Supplying, erecting & marking SPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 57 5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 58 5-3-29Supplying, fixing and commissioning MCB type change over switch 2 pole, 63 A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 59 5-3-32 Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 60 7-9-4 Supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. CB-CL/CU 61 7-9-5 Supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. CB-CL/CU 62 7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. CB-CL/CU 63 4-4-5 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 64 Cable Joint Kit for armoured cable 20 upto 120Sq. MM Cable 65 GI Tar for service wire support with bobine. 66 Kit kat Type fuse 16A 32A 63A 120A 67 Taparia Tester 68 Spaner Set 69 Control Panel HRC Fuse 70 Supplying And Erecting Transformer Fidder Piller 71 5-2-19 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation. 72 Bag filtter for 250/500/1000 LPH RO plant 73 Small cartridge filter 74 Big size cartridge filter 75 Coin mechanisum unit 76 Aster RO ATM unit 77 MECH-101 RO membrane cleaning chemical liquit -5 ltr 78 Supplying and erecting MS Pole Bracket 1100mm long (65-65-6) 79 Supplying and erecting aluminium standed cunductors 7/3.10 mm (Ant.) 145 Kg/Km) 80 Supplying and erecting ACSR aluminium standed cunductors 6/1-2.59mm Kg/Km 81 Supplying and erecting GI stay set for Pole including loops insulators height with achor plate 300x300x6 mm GI Wire 7/8 SWG 82 Supplying and erecting RSJ (Girder) Pole 125 x 70 mm (13.3Kg/m) 83 Supplying and erecting shackle type LT medium insulator 75x115 mm dia. With GI streep Nut Bolts etc 84 Supplying and erecting aluminium bobbin With GI streep Nut Bolts etc 85 Providing earthing with galvanized iron earth palte 60 x 60 x 0.6 cm with all materials 86 sand and Carban
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
45.
Housing Urban and Rular Development #10778154 Price Bid
Tender For Construction Of 33/11 Kv Sub-Station In Sector 146, Noida. - S/E of Terminal Gantry Structure of R.S. Joist - 175x85 mm. 19.5 Kg/Mtr. 6.1 Mtr. above the ground and 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. with 2 nos channel 175x85 mm suitable for Disc & Pin Insulator Including earth excavation back filling making plinth of required height and with required fabrication as per drawing. complete in all respects as per direction of E/I.(AOR) 2 S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama/UPPCL approved. as per direction of the E/I. (AOR) 3 Supply, Errection, Testing & Commissioningof 33 KV Outdoor VCB with required str, 1250A, 1500MVA, 25KA, Motorized 750MVA/1250Amp/ with transformer control & relay pannel includingCT, PT with structure. complete in all respectsMake: Crompton/ABB/Schneider as per specification and direction of E/I. (AOR) 4 S/E of Busbar Gantry Structure of 105 Lbs/Yard Rail pole 6.50 M long 5.2 Mtr. above the ground level and 1.30 Mtr. Below in 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. With M.S. angle 100x100x8mm (12.1Kg/M) mm suitable for Disc insulator including earth excavation, back filling, making plinth of required height and with required fabrication as per drawing complete in all respects as per direction of E/I.(AOR) 5 S/E of 33 KV, 1250A Bus Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. Thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/M and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects Make: Jaipuria/Rama as per direction of the E/I. (AOR) 6 S/F of 33 KV fuse set out door type of Relco/Rama make complete including structure as per drawing. Complete in all respects.(AOR) 7 S/E of 33 KV Lightning Arrestors with Structure made of M.S. Channel 125x65 mm. 13.1Kg/M top of M.S. Angle 50x50x6 mm. 4.5 Kg/M Lightning Arrestors/Post Insulator are to be mounted on M.S. Plate of 200x150x8 mm. Height of structure is to be 3.5 Mtr. above ground and 1 Mtr. below ground on a 75 mm. thick cement concrete pad with 1:4:8 cement concrete foundation, making plinth of required height including all fabrication as per drawing complete in all respectsMake: Elpro/Oblum/W/Sas per direction of E/I. (AOR) 8 Supply & fixing of 33 KV with 11KV 4 Nos SetB&S type strain Disc insulators 120KN E&M strength. as per drawing complete in all respects Make : Jaishree/BHEL/WS/RR as per direction of E/I.(AOR) 9 Supply & fixing of 33 KV tension fitting suitable for panther conductor and 120KN E&M 11KV disc insulator set of 4 complete in all respects as per direction of E/I. (AOR) 10 Construction of 33 KVtransformer plinth as per drawing. with all material, labour and T&P etc. required for proper completion of the work as per specifications of UPPCLas per direction of E/I.(AOR) 11 Providing and fixing of G.I Chain link fabric fencing of required width size 50x50mm including strenthening with 2mm dia wire or nuts,bolts and washers as required complete as per the direction of the Enginner-in- charge.made of G.I wire of dia 4mm PVC Coated to achive outer dia not less 5mm in required colour and shade.complete in all respect as per ditection of E/I(AOR). 12 Construction of boundary wall in brick work with cement mortar 1:6 (1 Cement : 6 Coarse Sand) for chain link including plaster in cement mortar 1:4 (1 Cement : 4 Coarse Sand) and finishing with water proofing cement paint complete as per attached drawing & complete in all respects as per direction of E/I.(AOR) 13 S/Fixing of 33 KV Post insulator 2x22KV of approved quality and make with all necessary material required for proper fixing including structure made of 125x65mm MS Channel (2.5Mtr above ground of 1 mtr below with ground with grouting 1:3:6 cement concrete including all labour, material, T&P etc. required for proper completion of the work. as per drawing. complete in all respectsMake: Jai shree / BHELas per direction of E/I (AOR) 14 1 nos1250A, VCB of (350MVA) 18.4 KA reputring capacity at 11 KV rated,totally enclosed, air insulated metal card housing floor mounting horizontal isolotion vermin proof fully interlock horizontal draqout type having isolation features and control devices complete with following. (AOR) 15 8 nos single phase double core current transformer 300/5.5/5 Amp epoxy cast resin isulated class of isulation E as per SLD. 16 core 1-15 VAburden class 1.0 for meeting 17 core 1-15 VAburden class 5P10 for protection 18 one no.numerical microprossor based three phase over current (IDMT element )with earth fault relay with instantaeous elements. 19 1 no Anti Pumping device 20 1 no circuit breaker control switch for electrical (T/N/C) 21 1 no limit switch for test & service 22 1 no Ammeter (0-3000Amp & 0-5-Amp) with selector switch (96mm Square. 23 1 no Electronic type digital energy analyser having 30 Days memory and parameters of KW-KWH,Power factor, frequency etcsuitablefor BMS compatible with all accessories. 24 1 no tri vector meter 25 1 set of following indicatinglamps 26 Red,Yellow,& Blue for Phase indication 27 Amber for trip indication 28 Redon Green off 29 Spring charge indication 30 Auto trip indication 31 1 No Hooter with hooter acceptance and reset push button 32 1 No master trip relay (Eletromechanical type) 33 1 set of fuses ferrules wiring etc as required 34 Note: All Spare contact of breakers or any other equipment inside the breaker shall bewired upto the outgoing terminal strip with appropriate terrules/coding . The terminal strip rating shall be suitable for coneccting two wires of 2.5 sqmm subjected to providing minimum size suitable for 4/6 sqmm. (Make- ABB, Crompton, Schnieder, Seimens) 35 11KV H.T Panel describe as above 36 Construction of control cable trench of required size 0.30x0.45 Mtr. bricks class designated-100 work including plastering etc. and covered with R.C.C. Slab (0.50x0.60 M) size complete with all material, labour and T&P etc. required for proper completion of work. complete in all respects. As per direction of E/I.(AOR) 37 S/Filling of 20 mm. stone grit in yard of size26x36mtr75 mm. thick complete in all respects. (AOR) 38 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 39 Supply & laying of earth mat in the switch yard of the Sub-Station for all Electrical Equipments and structure by laying of M.S. Round bar of 32 mm. dia. in 750 mm. deep trenches and earth electrode 3.0 M. long of M.S. round bar 32 mm. dia 0.5 M below ground level. The work include welding/bending/flooring of M.S. round bar and connection all steel structure in switch yard with earth mat by means of M.S. Strip of size 50x6 mm. including all labour, materials, T&P etc. required for proper completion of the work as per details specification of UPPCL Complete in all respects as per direction of E/I. (AOR) 40 Painting of (Complete sub-station) Terminal Gantry, Lighting arrestor, Busbar Gantry, Line Isolator & Bus Isolator Structures, Post insulator, Fencing, Poles and other structure complete with two coats of Al. paint over red oxide. (AOR) 41 S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I.(AOR) 42 Supply and laying of Control Cable for metering as per direction of E/I. (Gloster/Grandley/Havells/ Polycab/ Diacab make) (AOR) 43 (a) 2.5 Sq. mm. 2 Core Copper 44 (b) 2.5 Sq. mm. 4 Core Copper 45 (c) 2.5 Sq. mm. 10 Core Copper 46 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-48 47 S/E of 125x65 mm. MS Channel (13.10 Kg/M) 1.5 M long fixing in control room for OCB/VCB pannel complete in all respects as per direction of E/I.(AOR) 48 Supply/Fixing of MS ladder of size 5 mtr long and 0.4m width with MS angle 40x40x6mm incl painting etc . complete in all respect as per direction of E/I.(AOR) 49 Supply, Installation, Commissioning & Testing of Battery charger 24V 24V/40Amp float cum Boost battery charger with dropping diodes suitable for I/P 230V±10%, 1 Phase, 50Hz Type FCBC as per PVVNL Specification, maximum continuous output ratings (outpur voltage in float mode 25.80 Volts and in Boost mode upto 33.0 Volts), output current 40A, Plus trickle charging currentof battery floatmode 20A(Max), Boostmode 20A Load terminal, 20A, Battery terminal 20A, Starting rate 10A upto 2.35 V per cell, Finishing rate 10 Aupto 2.75 V Per cell, Output ripple 1% PP at full load and 25.8V DC, output regulation (floatmode) ±1%for ±10% supply voltage fluctuation and ±10% to 100% load variation, Automatic/manual mode of operation, Automatic and manual terminal charging, control configuration 1-phasefull wave controlled, thyristor bridge feed through 1-phase transformer and controlled by constant current/protential controller with load liminting feature and integrated non compartmentalized DCDB with 01 No 60A MCCB incomer, 5 Nos 16AMCB, sheet thickness 2mm, protection as per detail specification enclosed. 50 IS: 13947) IP-42/ maximum Permissible input volage ±10% of 230V AC, Electronic protection with auto reset against short circuit and overload ,DC over voltage short circuit at charger output terminals, thyristor by fuseing with protection against over charging, efficiency of rectified >65% at rated load, Power factor 0.7 lag at D.C. Current 230V Input with ANC cooling typeand Class F type insulation.For Battery : 240V/200AH Tubular type Battery Bank consisting 12 Cells of each 2V/200 AH dry & uncharged along with wooden stand & accessories (AOR) 51 S/Installation, testing & commissioning of out door type 10 MVA with on load tap changer Power Transformer as per ISI specificationincluding loading, unloading, local carriage & erection of the same on existing plinth & making all necessary connection etc. Complete in all respects Make: Crompton/ Alstom/BHEL/ABB/Schneider as per direction of E/I. (E-12) or approved GTP from UPPCL/PVVNL cable termination box with disconnecting facility for 33 KV XLPE cable at 33 KV side.cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.On load tap changer +/- 7.5@ 2.5% Bi directional roller, Conservator with drain valve, Earthing terminals, Double diaphragm explosion vent, Radiator with top & bottom shut off valve, First filling of oil including make up fill, Silica gel breather with oil seal, Rating and diagram plate, Air Release plug, Buchholz relay with shut off valve, Winding temperature indicator (WTI), Oil Temperature indicator (OTI), Megenatic oil level guage, Pressure relief device, Marshalling box .Aproved By CEO. (AOR) 52 S/Laying of Aluminium conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a depth of 75 cm. below ground level over a cushion of 75mm. Below ground level over a cushion of 75mm. thick snad alround and protected with burnt bicks on sides and on top. on surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. P.S. No. 501 (Gloster/Grandly/Polycab/ Havells/Diacab. make) 53 a) 50 Sq.mm. 3½ Core 54 b) 25 Sq.mm. 3½ Core 55 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. P.S. No. 1131 56 Supply and fixing of Lugs(socket) forCable P.S. No. 504 57 i) 25 Sq.mm. 58 ii) 50 Sq.mm. 59 iii) 120 Sq.mm. 60 iv) 185 Sq.mm. 61 supply and burying earth electrode for lighting conductor of 600mmx600mmx6.0mm G.I. Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. Pipe for watering funnel, 30cm square C.I frame with hinged cover masonry housing alternate layrs of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects.P.S. No. 706 62 S/F of brass nickle plated compression gland for PVC isulated & armoured served sheathed, underground cable incl. rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of E/I P.S. No 503 63 (a) Size 25 mmx 3.5 core 64 (b) Size 16 mmx4 core 65 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) 66 S/B of 40 mm dia x4.5 meters long GI pipe vertically of earthing having 12 mm dia. Holes spaced 75 mm apart drilled up to 2 meter from the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in GI pipe up to appron) and from appron to switch board (The cost of GI wire and pipe will be extra) upto switch board, 30 cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layes of charcoal / coke and salt at least 150mm thick alround etc. as per directions of engineer-in-charge complete in all respects as per drawing as per PS No. 701 67 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing ead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (B) 68 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 69 S/E of overhead line with ACSR(Painther/Dog) Conductor on pole/service bracket including binding etc. complete in all respects PS No 627 70 S/F of fire bucket, round bottom made of GI sheet 9-11 liters capacity duly painted as per fire brigade design, supported on hanging bracket, chained & locked initially filled with fine river sand, water as per direction of E/I. P.S. No. 1133 71 S/F of shock treatment chart (Prescribed under I.E. Rules) duly framed with glass & supported from back with hard board or soft board with supply of all material labour and T&P for proper completion of work. P.S. No. 1134 72 S/L of 1800x900x12 mm. thick chequered rubber matting of testing quality. P.S. No. 1136 73 Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 74 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :Make : Raychem/ Denson/ :DSR 2018 75 120 Sq.mm.I.No. 10.5.2 76 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :Make : Raychem/ Denson. 77 120 Sq.mm. UPERC Pg-27 78 185 Sq.mm UPERC Pg-29 79 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.DSR-2018/Item No. 14.13.2 80 80mm dia 14.13.2 81 100mm dia 14.13.3 82 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 83 Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR-2018/I.No. 13.23 84 Supply and fixing Clamps, bolts, nuts etc.complete in all respects (DSR-2018/I.No. 2924) 85 Supply of following type high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. Complete in all respects Make: Gloster/ /Universal/ Polycab/ Havells/ Diacab .as per direction of E/I. 86 i) 185 Sq.mm. 3 Core UPREC 2019 P-41 87 ii) 120 Sq.mm. 3 CoreUPREC 2019 P-41 88 S/F of 11 KV pin 12 long with insulator of Jai Shree/HBHEL on cross arm fixed on HT pole including all T/P etc UPERC P-39 Annexure-16 89 S/F of 11 KV TPMO Relco/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC P-48 90 S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects Make : P.M./Kanohar/LD Power/Paramix as per direction of E/I (UPERC 2019) P-51 91 Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 92 BOQ-BSupply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 93 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 94 Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 95 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 96 Supply of 300 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 33 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respectsas per direction of E/I. Make: Gloster/ /Universal/ Polycab/ Havells/ Diacab . (UPERC P-47) 97 S/F of jointing of 300 sq. mm out door type type 33 KV jointing kit heat Shrinkable type for 33 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson. as per direction of E/I. (UPERC P-47) 98 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 99 S/Making of Straight through joint suitable for 300 sqmm x 3 core 33KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson. As per direction of E/I. (UPERC P-47) 100 S/E of over head line with ACSR Panther Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 101 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) 102 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 103 S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 300 Sqmm 104 Painting of the electric pole with 2 coat of AI paint over red oxide primer complete in all respects As per PS No. 634 105 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 106 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 107 S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 108 Numbering of poles with combination of yellow and black colour paint etc complete in all recpects as per direction of E/I (AOR) 109 S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (creator poly extrusion/duraline/rex/times/ naranderplast/pioneer make). (AOR) 110 Providing and laying of200mm dia 6mmthickness through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) 111 S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama. as per direction of the E/I. (AOR) 112 Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N.8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm 113 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N.7.9/P30) 114 Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required..(DSR Electrical 2018/Item 13.23 Page 50) 115 Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation,ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) 116 Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturers specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) 117 Lettering with black japan paint of approved brand and manufacturer (AOR) 118 Providing and laying in position cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.7 P-48 119 Providing and laying in position cement concrete1:3:6 (1 cement : 3 coarse sand (zone-III) :6 graded stone aggregate 40 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.9 P-48 120 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) 121 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion..(AOR) 122 BOQ-CWiring points for light with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire,GP Box piano type switch and ceiling rose/angle/batten holder3mm thick phenolic laminated backelite sheet etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 138C 123 Wiring points for Fan/fresh air fan (light duty exhaust fan) with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire,GP Box piano type switch and ceiling rose3mm thick backelite sheet etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 140C 124 Wiring points for Plug with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and socket etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 141C 125 Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. P.S No. 1405 Cat AAA 126 S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. PS No. 1002 Cat A 127 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) 128 Supply and fixing of power plug with 15A / 250 V flush type switch and 5 pin 15 A / 250V flush type socket in suitable M.S. box of 175 mm x 100 mm x 50 mm size with Bakelite sheet cover 3 mm. thick fixed with brass machine screws and cup washer. P.S. No. 1139 129 Supply and wiring of submain with two number 6 sqmm FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 25mm dia heavy duty (2mm thick) PVC Conduitl with one number 4 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. as per PS No. 217 (C) 130 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. PS No. 641(Make - Bajaj/ Transrail /Volmont/ NERI) 131 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. P.S. No. 1421 Cat. AAA 132 Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Grandley/Gloster/Havells, Polycab, Diacab. make) P.S 501 133 a. 25 sq. mm 3.5 core 134 b. 35 sq. mm 3.5 core(PS No. 501(k) 135 S/F of sintex type junction box model no. IIGSJB 2817 of size 240x130x110mm with hinges and locking arrangment & MS clamp of 50x6mm flat, complete in all respects including 2 no. G.I pipe 1.5 dia having 1.0 meter length each and chuck nut for cable connection etc. as per direction of E/I. (AOR) 136 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 e (ii) 25 A TPN 137 S/F surface/flush mounting 6 ways TPN distribution board without MCB complete in all respects and as directed at site. PS No.1027 Cat A 138 S/F of hexagonal Round GP fan box with hexagonal side of approx. 80mm in lenth fabricated from 16SWG MS Sheet incorporating 10mm dia M S round bar duly duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all materials, labour, T&P etc. for proper completion of work PS No. 1149 139 S/F of fan regulator dimmer 300/400W ISI mark on the existing switch board including making connection T&P etc. for proper completion of work to the satisfaction of Engineer of work. PS No. 1203 140 S/F of Palm or pin type tin plated copper cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of E/I. (PS No. 504 (e)25 sq.mm 141 f) 35 sq. mm 142 S&F of 63 Amp. 4 pole MCB(10 KA) C Curve as per PS No. 1020 (A) Cat-A 143 Supply and fixing of following size heavy duty industrial type Exhaust fan with louvered shuttersof approved make complete with wire guard mesh, mounting sings frame bracket etc. but without regulator suitable for use on 230/240V 50Hz single phase AC supply and conforming to IS: 2312-1967 with update amended (900 RPM) (Havells single phase Model-300mm)300mm dia (AOR) 144 Supply and Fixing of Ceiling fan 1200 mm dia ISI marked Make-Baja, Crompton, Havells or equivalent make.(AOR) 145 BOQ-DS/F of Steel Tubular Pole 11 M long designated 410-SP-56 in 1:3:6 Cement, Concrete graded stone aggregate of 40 mm. Nominal size & foundation including excavation back filling etc. complete in all respects as per direction of UPERC P-54 146 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 147 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 148 Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 149 Supply of following type high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. (Gloster/Universal/Havells, Polycab, Diacab.make)(UPERC 2019 Pg-28) 150 i) 185 Sq.mm. 3 Core E-48 151 Laying of One number PVC insulated and PVC sheathed/ XLPE power cable of 11KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N.8.3.2/P31) Above 120 Sqmm and upto 400 Sqmm 152 S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-29 153 185 Sq.mm. 154 S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE-100 grade as per IS code 4984 with excavation at depth of 1.20 Mtr. Below ground level i/c the cost of cutting of pipes for making upto length and making joints complete all respects asper direction of E/I (Crator Poly extrusion/Duraline/Rex/time/narander plast/Poineer make) (AOR) 155 Providing and laying of MS Pipe of 200mm dia 6mmthickness as per IS 3589 grade FE 410 through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) 156 S/Making of Straight through joint suitable for 185 sq.mm x 3 core 11 KV armoured cable as per ISS& complete as per the direction and satisfaction ofE/I(Raychem, Denson.Make) UPERC 2019 Pg-29 157 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 158 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. DSR 2018 13.4 159 S/F of 11 KV pin 12 long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC Pg-39 160 S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 185 Sqmm 161 Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 162 Numbering of poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/I. (AOR) 163 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 164 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 165 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N.7.9/P30) 166 S/E of over head line with ACSR Dog Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 167 S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 168 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) 169 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 170 Providing and laying in position cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.7 P-48 171 Providing and laying in position cement concrete1:3:6 (1 cement : 3 coarse sand (zone-III) :6 graded stone aggregate 40 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.9 P-48 172 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) 173 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion..(AOR) 174 Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturers specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) 175 Lettering with black japan paint of approved brand and manufacturer (AOR) 176 Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation,ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) 177 Operation of 33/11 KV Sub-Station round the clock in 3 shifts of 8 hours each by a team comprising of one electrician, skilled operator (having minimum qualification of ITI (Electrician grade) and one unskilled helper in each shift for operation of S/S equipments including maintenance of 11 KV incoming and outgoing Switchgear panels, 33 KV Switchgear pannels, battery and battery charger, 33/11 KV Transformer with control pannels, HT/LT Cable/Lines along with all associated equipments installed at 33/11 KV Sub-Station compus, (Contractor may deploy required man power, as and when required for attending breakdown within minimum time as detailed in Tech. Specification and distribution code) and maintain the required records as per U.P.P.C.L. (AOR) 178 SUBHEAD-I (Equipments H T Panels Transformers and Main L T Panel, capacitor Panel 11 KV RMU Panel (3 Way RMU) Design manufacture testing at works supply, installation testing & commissioning of 3 panel Board 11KV, Indoor tree standing, floor mounting totally enclosed mela clad VCB insulated comprising of 1 Nos 11KV isolater load break switch and 2 Nos Vaccum circuit breaker as outgoing enclosed in robotically laser weided non-extensible type stainless steel SF6 VCB enclosre with SelfPowered relay (IDMTL O/C +E/F) as HT switchgear including suitable transformer protection relays, metering, indicators push buttons, copper busbars, etc as per the requirement complete as required The fault with stand capacity shall beminimum 20KA for 1 second including four cable entries for two incoming cable and two outgoning cable glands and lugs suitable for 2x 240/185 sqmm XLPE armoure cable (Make- ABB, Crompton, Schnieder, Seimens) 179 Incomer shall be provided with Incomer shall be provided with integral Earthing Switch with making switch Live Cable Indicating LEDs energized thru Capacitive Voltage Deviders Transparent Viewing window for verification of Earthing Right Angle terminal protectors / Boots Electrical & mechanical indications as required Outgoing feeders: Two nos. Vaccum circuit breakers with the following SF-6 insulated 630A Circuit Breaker integral Earthing Switch with making switch Emergency Trip Push Button, Electrical & mechanical indications as required Shunt Trip coil for external trip signal Live Cable Indicating LEDs energized thru Capacitive Voltage Dididers Transparent Viewing window for verification of Earthing Right Angle terminal protectors /Boots IDMT relay for Circuit Breakers self powered, Merlin Gerin type VIP35 or equivalent with required protection CTs of suitable ratio Cable box for incoming and outgoing shall be suitable for icrminating, 11KV, XLPE insulated Aluminium conductor armoured cables One set inbuilt DC power packTransformer protection relays as required as per SLD
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Uttar Pradesh View Result →
46.
Power #10776503 Price Bid
Tender For UNDER GROUND CABLE CROSSING OF 33 KV OVERHEAD CIRCUIT OF G-2 FEEDER TOWARDS UDHAMPUR END AT GUJJAR BASTI, JAMMU ON TURNKEY BASIS.- 1 33KV, Single core 630 mm2 Aluminium, round wire Armoured XLPE Cable , FRLSOne spare cable 2 Double wall corrugated pipes of HDPE with Outer Dia 180 mm Inner Dia 152 mm for laying of 33 KV XLPE Cable, as per IS-14930 (Part-II) & TEC GR No. GR/DWC-34/01 SEP 2007, with compression strength at 5% applied defelxtion load ≥450N and with impact strength 5 kg striker falling through a height of 570mm Energy=28 joules. 3 Cable Termination Kits (indoor/outdoor) 4 GI Pipe 150 mm dia with required no of collars for road crossing including termination points 5 Earthing Complete with G.I plate 600mm X 600 mm X 6mm, GI flat 50mmX6mm, and 25mm X 5mm alongwith earth enhancement material viz-av-viz charcoal , salt & good earth by GI Pipe 50 mm2.5 mtr longthrough GI Strip. 6 Horizontal Directional Drilling (04 No.s of tubing) forU/G Double track railway crossing alongwith insertion ofHDPE Pipe (40m x 4 no. = 160 m) 7 Laying of 33 KV, Single Core 630 Sqmm XLPE Cable through HDPE Pipe in 04 tubings, complete in allrespects 8 Excavation in any type of soil for laying of cables 9 Sand for cushioning of HT underground cables 10 Back Filling of available excavated earth 11 Non Communicable 33 kV Fault Passage Indicators ( as per techical specification attached in the tender document) 12 4-POLE CABLE SUPPORT STRUCTURE ALONWITH 02 NO.S OF ISOLATION POINTS 13 11 Mtr. Long ST Poles (ST-410 SP 56) 14 G.I Channel (100x50x6) mm sq 15 200 mm2ACSR Panther conductor 16 P.G. Clamp for 200 mm2 ACSR Panther conductor 17 GI Nut Bolts off sort sizes 18 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 19 33kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 20 30 KV Lightening Arrestors (30 kV,10 kA,Station Class ,ZnO, Polymer) gap less 21 Tension Fitting suitable for 200 mm sq conductor. 22 Galvanised Nuts and Bolts with Washers 23 33 KV Danger Plates with Clamps 24 Anti-Climbing Device with Clamps 25 Red Oxide Paint 26 Aluminum Paint. 27 Cement Bottoming (1:2:4 mix as per REC Standards, 0.7 cum/pole) 28 33 kV Porcelainic Isolator without Earthing Blade(36 KV,1600A, Outdoor,3 poles, 25 KA) 29 Galvanised Stay Set Complete with insulator,turn buckle etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
47.
Power #10776500 Price Bid
Tender For UNDER GROUND CABLE CROSSING OF 33 KV OVERHEAD DOUBLE CIRCUIT OF G-3 FEEDER TOWARDS UDHAMPUR END AT GUJJAR BASTI, JAMMU ON TURNKEY BASIS ON TURNKEY BASIS.- 1 33KV, Single core 630 mm2 Aluminium, round wire Armoured XLPE Cable , FRLSOne spare cable 2 Double wall corrugated pipes of HDPE with Outer Dia 180 mm Inner Dia 152 mm for laying of 33 KV XLPE Cable, as per IS-14930 (Part-II) & TEC GR No. GR/DWC-34/01 SEP 2007, with compression strength at 5% applied defelxtion load ≥450N and with impact strength 5 kg striker falling through a height of 570mm Energy=28 joules. 3 Cable Termination Kits (indoor/outdoor) 4 GI Pipe 150 mm dia with required no of collars for road crossing including termination points 5 Earthing Complete with G.I plate 600mm X 600 mm X 6mm, GI flat 50mmX6mm, and 25mm X 5mm alongwith earth enhancement material viz-av-viz charcoal , salt & good earth by GI Pipe 50 mm2.5 mtr longthrough GI Strip. 6 Horizontal Directional Drilling (04 No.s of tubing) forU/G Double track railway crossing alongwith insertion ofHDPE Pipe (40m x 4 no. = 160 m) 7 Laying of 33 KV, Single Core 630 Sqmm XLPE Cable through HDPE Pipe in 04 tubings, complete in allrespects 8 Excavation in any type of soil for laying of cables 9 Sand for cushioning of HT underground cables 10 Back Filling of available excavated earth 11 Non Communicable 33 kV Fault Passage Indicators ( as per techical specification attached in the tender document) 12 4-POLE CABLE SUPPORT STRUCTURE ALONWITH 02 NO.S OF ISOLATION POINTS 13 11 Mtr. Long ST Poles (ST-410 SP 56) 14 G.I Channel (100x50x6) mm sq 15 200 mm2ACSR Panther conductor 16 P.G. Clamp for 200 mm2 ACSR Panther conductor 17 GI Nut Bolts off sort sizes 18 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 19 33kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 20 30 KV Lightening Arrestors (30 kV,10 kA,Station Class ,ZnO, Polymer) gap less 21 Tension Fitting suitable for 200 mm sq conductor. 22 Galvanised Nuts and Bolts with Washers 23 33 KV Danger Plates with Clamps 24 Anti-Climbing Device with Clamps 25 Red Oxide Paint 26 Aluminum Paint. 27 Cement Bottoming (1:2:4 mix as per REC Standards, 0.7 cum/pole) 28 33 kV Porcelainic Isolator without Earthing Blade(36 KV,1600A, Outdoor,3 poles, 25 KA) 29 Galvanised Stay Set Complete with insulator,turn buckle etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
48.
Public Administrative Department #10774781 Price Bid
Tender For Lighting Work In Saumitra Forest Park - Supply and Installation of Decorative steel pole is made out of mild steel galvanized two profile bottom profile 1000mm x125mmx4.00 mm and upper ribbed profile 2500mmx81mmx3.5mm with cast iron embelishment E8 . the pole has a service window atbottom section with heavy duty four way connector and a MCB mild steel base plate 300x210 mm with four nos mounting holes is fixed with welded with bottom section pole is primer coated and polyurethane painted.Decorative pole shall be installed at desired location including foundation of the pole by making cement concrete foundation of 1:2:3( 1 cement: 3 course sand : 6 graded stone aggregate 40mm nominal size) with the help of anchor bolts and 38mm G.I sleeve as required. make: phillips, bajaj, as per direction of E/ic (PSR Begam Hazrat Mahal Park) 3 S/F of ornamental type luminaire 40-45 watt LED post top fitting make of aluminium 534 mm long housing duly powder coated/PU painted with PC/PMMA clear/frosted diffuser with sturdy triple arm MCPCB having high umen LEDs are mounted on aluminium heat sinks. make: phillips, bajaj as per direction of E/ic(PSR Begam Hazrat Mahal Park) 4 Supply and fixing of DWC HDPE Pipe along with all accessories like socket, band, coupling etc. confirming to IS 14903 PartII complete with fixing and cutting jointing etc. (63mm OD and ID51 mm nominal) DSR/2022(E/M) No 14.161) 5 S/B Supply of feeder pillar Box, with alumnium bsuhar-4 strip enclosure CRC & street powder coated outdoor type alumnium busbar 20x44 strip, MCB DP 32m AMP-4 Nos. 3pin socket 32Amp-1 no. enclosure size 300x350x200mm (PSR) 6 S/B of Earth rod 20 mm dia 2.5 mt long including GI wire 7/16 SWG to connected earth rod and earth clamp on pole, 3 mtr long steel conduit to carry earth wire along the pole complite as per approved of E/Ic (PSR) 7 Supply & fixing of 30mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 500 mmbase plate 32 mm thick suitable for wind velocity as per IS 875 part 3 &having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. SOR-655/18 8 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect. As per PWD shcedule 2018 SI No.1455 CAT AAA 9 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter,voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestaltype for Cat-B and C only. As per PWD schedule 2018 SI No.802 10 Incoming 400 AMP TPN-01 Nos. Outgoing- 200 AMP TPN-2 Nos & 63 amp TPN-01 Nos. 11 Incoming 200 AMP TPN-01 Nos. Outgoing- 100 AMP TPN-1 Nos and 63 amp TPN-03 Nos. 12 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. As per PWD schedule 2018 SI No. 501 13 10 sqmm 4 core 14 16 sqmm 4 core 15 95 sqmm 3-1/2 core 16 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRCfuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect As per PWD schedule 2018 SI No. 807 17 40 A TPN 18 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). As per PWD schedule 2018 SI No. 702 19 Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia. heavy guage rigid steel conduit on surface, with one number 14 SWG copper earth continuity wire etc, complete in all respect. As per PWD schedule 2018 SI No. 1301(B) 20 PART-B 21 H.T/L.T Work 22 S/F of double pole structure with 2 nos ST. pole for S/S 410 SP-55 11 Mtr. long in 1:3:6 CC foundation 1/6 of pole length below G.l. and 30cm above G.1. 20cm thick around the pole with 2 nos. channel 125mmx75 mm one No. Chennel cross arm of 75mmX 40mm 2 No. 50X50X6mm sngle iron bracings with necessary nut bolts & packing pieces complete with painting as per direction of B/L PSR Bond No.87/CE/EE(E/M)/2021, Dated 09-11-2021 23 S/F of 11 KV Pin insulator with G.1. Bolt/spindle nut etc. complete in all respects. PSR Bond No.87/CE/EE(E/M)/ 2021, Dated 09-11-2021 24 S/E of 11 K.V L.A. set of 3 wire. suitable for mounting on steel support complete in all respect as per direction of E/I. PSR Bond No.87/CE/EE(E/M)/2021, Dated 09-11-2021 25 S/E of 11 K.V. T.P.M.O. switch on pole including handle rod etc. complete in all respects as per direction of E/Ich. PSR Bond No.87/CE/EE(E/M)/2021, Dated 09-11-2021 26 S/E of 11 K.V. D.O. fuse set on pole complete in all respect as per direction of E/1. PSR Bond No.87/CE/EE(E/M)/ 2021, Dated 09 11-2021 27 Supply and laying of 70 Sqmm 3 core 11 KV standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded Galvanised flat steel strip armoured cables confirming to 1.S. 709 (Part-II with latest amendments) II KV grade at a depth of 900 m below ground level over a cushion of 100 mm thick fine river sand a around and protected with well burnt bricks on sides and on top pu across. The armouring of cable shall be properly connected wi earth conductor by clamps etc. PWD SOR No: 506 (d) 28 S/F of 70 Sq.mm size 3 core XLPE 11 KV outdoor type jointing kit proper completion of work as per direction of E/I A.R. Make: Raycheme, Mahindra. PSR Bond No.02/CE/EE(E/M)/2022, Dated 19.04.2022) 29 S/F of level 2 following capacity 11/0.433 K.V. Al wound! conventional 50Hz 3 phase oil immersed naturally cooled distribution T/F confirming and with amendments there of, having losses as per BEE standered with all standard fittings, including first filling of oil complete in all respects, of make UPPCL/KESCO Approved 30 (a) 100 KVA 31 Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6. terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.1. Strip will be extra)Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. S.I.No-726 B/18. 32 S/L of 25mmx3mm Gl strip from earth electrode directly in the ground as required complete in all respect Item No 716-SOR-2018 33 Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked.The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinges etc. The cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour, T&P etc. for proper completion of work. PWD SI No: 1142 34 S/E of 2.24 mtr. Long cross arm 50mmx 50mm. channel on pole including clamps, eye bolts etc. with red enamel paint as per direction of E/Ich. (Analysed as per SOR- 2020 civil) 35 S/L of following size G.l. B class pipe at a depth of 750mm below ground level as cable carrier as direction of E/Inch. (PSR Bond No.02/CE/EE(E/M)/2022, Dated 14.09.2022) 36 (a) 80 mm dia 37 S/F of 11000 V danger board and Fabricated from 10 gauge MS sheet on pole as per electricity rule as per direction of E/Ic SI.No. 1109/18
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Uttar Pradesh View Result →
49.
Power #10746870 Price Bid
Tender For Deposit Work In The Area Of Edsd Naujheel Under Edd-Mant, Mathura- 1 Carriage Of 8.5 Mtr Long Pcc Pole From 132 Kv Store Center Mathura To Site Of Work Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. ( Distance 00-70Kms. ) 2 Carriage Of 9 / 11 Mtr Long St Pole From 132 Kv Store Center Mathura To Site Of Work Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. ( Distance 00-70Kms. ) 3 Carriage Of 16 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 4 Carriage Of 25 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 5 Carriage Of 100 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 6 Carriage Of 250 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 7 Carriage Of 11 Kv Xlpe Cable Size 3X70 / 3X120 Sq.Mm. Cable Form Store Center Mathura / Agra Including Cost Of Shifting Of Drum From Inside Of Store, Removing Of Cable From Drum And Re-Rolling Of Extra Removed Cableincluding Loading & Unloading At Both Ends. 8 Carriage Of 11 Kv Xlpe Cable Size 3X185 / 3X300 Sq.Mm. Cable Form Store Center Mathura / Agra Including Cost Of Shifting Of Drum From Inside Of Store, Removing Of Cable From Drum And Re-Rolling Of Extra Removed Cableincluding Loading & Unloading At Both Ends. 9 Carriage Of Line Material I.E. Conductor, G.I. Wire Tpmo Stay Rod, Disc Insulator, Cross Arm, Angle Channel And Other Required Material From Store Center At 132 Kv Substation Mathura To The Site Of Work Including Loading And Unloading Of Material At Both Ends. 10 Erection Of Single Pole Structure 8.5 Mtrs On Pcc Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 11 Erection Of Single Pole Structure 9 / 11 Mtrs On St Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 12 Erection Of Double Pole Structure 8.5 Mtrs On Pcc Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 13 Erection Of Double Pole Structure 9 / 11 Mtrs On St Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 14 Installation Of Stay Set With Grouting And Nuzzling Etc. As Per Respo Drawing Along With All Routine Material To Be Used For Such Works. 15 Earthing Of Poles By Fixing Earthing Rods And Binding With Earth Wire As Per Standard Norms Including Cost Of Labour T&P And Required Material For Such Work. 16 Laying, Sagging Stringing And Binding Of Acsr Weasel Conductor On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 17 Laying, Sagging Stringing And Binding Of Acsr Dog Conductor On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 18 Laying, Sagging Stringing And Binding Of Arial Bunch Conductor On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 19 Laying, Sagging Stringing And Binding Of Lt Pvc Cable On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 20 Laying Of 11 Kv Xlpe Cable Size 3X70 / 3X120 Sq.Mm. In The Trench / G.I Pipe / Hdpe Pipe And Re-Dressing Of Trench After Laying Of Xlpe Cablefor Proper Completion Of Work As Per Direction Of Supervising Engineer. 21 Laying Of 11 Kv Xlpe Cable Size 3X185 / 3X300 Sq.Mm. In The Trench / G.I Pipe / Hdpe Pipe And Re-Dressing Of Trench After Laying Of Xlpe Cablefor Proper Completion Of Work As Per Direction Of Supervising Engineer. 22 Filing Of Cable Box As Suitable Size As Per Direction Of Supervising Engineer. 23 Filing Of Straight Through As Suitable Size As Per Direction Of Supervising Engineer. 24 Chopping Of Tree Branches To Clear The Route Properly. 25 Mounting Of 16 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 26 Mounting Of 25 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 27 Mounting Of 100 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 28 Mounting Of 250 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 29 Cutting Of Cc Road For Making Depth Foundation For Erection Of Pole. 30 Installation Of 11 Kv Ct / Pt Combined Metering Unit On Existing Double Pole Structure Of Large & Heavy, Power Consumers To Avoid Possibility Of Theft Of Energy & 11 Kv Feeders At 33 / 11 Kv Sub- Station Including The Cost Of Accessories ( Nut & Bolt, Pvc Tape Etc. ) Required For Proper Completion Of Work Also Provided By The Contractor. ( Including Carriage Of New 11 Kv Ct / Pt Combined Metering Unit From Store Center Mathura To Site Of Work. ) 31 Fixing Of Meter Pilfer Box ( Service Connection Meter Holding Capacity ) Including Its Carriage From Electricity Store Centre Mathura To Site Of Work Including Grouting Of Meter Pillar Box In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms. 32 Grouting Of Pcc / St Pole In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms, Including Cost Of All Grouting Material. 33 Guarding Of 11 Kv Line By Laying Two Nos. Gi Wire Parallel And Fixing Of Lacings ( Tilli ) At A Distance At 2-3 Mtrs. As Per Direction Of Supervising Engineer / Respo Manual. It Includes The Cost O F Labour T&P Carriage Etc Required For Proper Completion. 34 Fixing Of Distribution Box On Erected Pcc Pole. 35 Re-Sagging Of Loose H.T / L.T Line As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T&P Etc Required For Proper Completion Of Work. ( Work Will Be Done Inside And Outside Of Village ) 36 Dismantle Of Old / Damaged Acsr Weasel Conductor / G.I. Wire From The Existing Line And Its Bundling And Stacking In Roll And Send To J.E. Store / Mathura Store. 37 Straightening Of Tilted Single Pole At Various Places By Straighteningof Pole Including The Cost Of Labour , T&P Charges Required For Proper Completion Of Work ( Inside / Outside Village )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
50.
Power #10746843 Price Bid
Tender For Deposit Work In The Area Of Edsd Laxminagar Under Edd-Iii, Mathura- 1 Carriage Of 8.5 Mtr Long Pcc Pole From 132 Kv Store Center Mathura To Site Of Work Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. ( Distance 00-70Kms. ) 2 Carriage Of 9 / 11 Mtr Long St Pole From 132 Kv Store Center Mathura To Site Of Work Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. ( Distance 00-70Kms. ) 3 Carriage Of 16 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 4 Carriage Of 25 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 5 Carriage Of 100 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 6 Carriage Of 250 Kva Transformer From Store Centre, Mathura To Pit Site With Loading & Unloading At Both Ends 7 Carriage Of 11 Kv Xlpe Cable Size 3X70 / 3X120 Sq.Mm. Cable Form Store Center Mathura / Agra Including Cost Of Shifting Of Drum From Inside Of Store, Removing Of Cable From Drum And Re-Rolling Of Extra Removed Cableincluding Loading & Unloading At Both Ends. 8 Carriage Of 11 Kv Xlpe Cable Size 3X185 / 3X300 Sq.Mm. Cable Form Store Center Mathura / Agra Including Cost Of Shifting Of Drum From Inside Of Store, Removing Of Cable From Drum And Re-Rolling Of Extra Removed Cableincluding Loading & Unloading At Both Ends. 9 Carriage Of Line Material I.E. Conductor, G.I. Wire Tpmo Stay Rod, Disc Insulator, Cross Arm, Angle Channel And Other Required Material From Store Center At 132 Kv Substation Mathura To The Site Of Work Including Loading And Unloading Of Material At Both Ends. 10 Erection Of Single Pole Structure 8.5 Mtrs On Pcc Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 11 Erection Of Single Pole Structure 9 / 11 Mtrs On St Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 12 Erection Of Double Pole Structure 8.5 Mtrs On Pcc Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 13 Erection Of Double Pole Structure 9 / 11 Mtrs On St Pole By Digging Of Pits Fitting Of All Relevant Accessories As Per Respo Norms. 14 Installation Of Stay Set With Grouting And Nuzzling Etc. As Per Respo Drawing Along With All Routine Material To Be Used For Such Works. 15 Earthing Of Poles By Fixing Earthing Rods And Binding With Earth Wire As Per Standard Norms Including Cost Of Labour T&P And Required Material For Such Work. 16 Laying, Sagging Stringing And Binding Of Acsr Weasel Conductor On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 17 Laying, Sagging Stringing And Binding Of Acsr Dog Conductor On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 18 Laying, Sagging Stringing And Binding Of Arial Bunch Conductor On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 19 Laying, Sagging Stringing And Binding Of Lt Pvc Cable On The Erected Pcc Pole / Stp Including Jumpering As Per Respo Manual. 20 Laying Of 11 Kv Xlpe Cable Size 3X70 / 3X120 Sq.Mm. In The Trench / G.I Pipe / Hdpe Pipe And Re-Dressing Of Trench After Laying Of Xlpe Cablefor Proper Completion Of Work As Per Direction Of Supervising Engineer. 21 Laying Of 11 Kv Xlpe Cable Size 3X185 / 3X300 Sq.Mm. In The Trench / G.I Pipe / Hdpe Pipe And Re-Dressing Of Trench After Laying Of Xlpe Cablefor Proper Completion Of Work As Per Direction Of Supervising Engineer. 22 Filing Of Cable Box As Suitable Size As Per Direction Of Supervising Engineer. 23 Filing Of Straight Through As Suitable Size As Per Direction Of Supervising Engineer. 24 Chopping Of Tree Branches To Clear The Route Properly. 25 Mounting Of 16 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 26 Mounting Of 25 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 27 Mounting Of 100 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 28 Mounting Of 250 Kva Transformer On The Double Pole / Plinth Structures And Connections Thereof. 29 Cutting Of Cc Road For Making Depth Foundation For Erection Of Pole. 30 Installation Of 11 Kv Ct / Pt Combined Metering Unit On Existing Double Pole Structure Of Large & Heavy, Power Consumers To Avoid Possibility Of Theft Of Energy & 11 Kv Feeders At 33 / 11 Kv Sub- Station Including The Cost Of Accessories ( Nut & Bolt, Pvc Tape Etc. ) Required For Proper Completion Of Work Also Provided By The Contractor. ( Including Carriage Of New 11 Kv Ct / Pt Combined Metering Unit From Store Center Mathura To Site Of Work. ) 31 Fixing Of Meter Pilfer Box ( Service Connection Meter Holding Capacity ) Including Its Carriage From Electricity Store Centre Mathura To Site Of Work Including Grouting Of Meter Pillar Box In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms. 32 Grouting Of Pcc / St Pole In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms, Including Cost Of All Grouting Material. 33 Guarding Of 11 Kv Line By Laying Two Nos. Gi Wire Parallel And Fixing Of Lacings ( Tilli ) At A Distance At 2-3 Mtrs. As Per Direction Of Supervising Engineer / Respo Manual. It Includes The Cost O F Labour T&P Carriage Etc Required For Proper Completion. 34 Fixing Of Distribution Box On Erected Pcc Pole. 35 Re-Sagging Of Loose H.T / L.T Line As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T&P Etc Required For Proper Completion Of Work. ( Work Will Be Done Inside And Outside Of Village ) 36 Dismantle Of Old / Damaged Acsr Weasel Conductor / G.I. Wire From The Existing Line And Its Bundling And Stacking In Roll And Send To J.E. Store / Mathura Store. 37 Straightening Of Tilted Single Pole At Various Places By Straighteningof Pole Including The Cost Of Labour , T&P Charges Required For Proper Completion Of Work ( Inside / Outside Village )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
TenderDetail
Loading tenders