View Bid Results For Glass Epoxy Tenders

We found 3810 Bid Results related to glass epoxy tenders. You can find Contractor details who won glass epoxy tenders along with contract details in Bid awards announcements section.

Filters
Stage
2783
611
416
Tender Publishing Platform
584
3226
State / UT
37
632
400
396
301
221
186
155
155
150
138
128
113
100
87
77
61
51
45
44
43
40
39
37
31
29
27
27
20
17
16
12
9
9
7
5
1
1
Contract Value
1163
733
1487
423
Publish Date
13
0
1
0
0
Sector
32
1221
609
416
223
192
157
136
123
115
108
68
53
47
47
42
30
30
29
27
23
21
16
13
13
13
13
10
6
3
3
2
1
Ownership
7
1874
1241
339
329
19
5
3
Within keyword
Active filters:
Showing 1–50 of 3810 tenders matching your filters
1.
Defence #11496759 Technical Bid
Tender for Material And Labour For Plain Cement Concrete (1:3:6) Type C1 (Using 20 Mm Graded Crushed Stone Aggregate For Fixing Holdfast Complete All As Specified And As Directed. , Supply Only Water Proofing Compound. , Material And Labour For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc , Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate ) As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specifed And Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour For Granite 20Mm Thick (Of Any Type) Work (Table Rubbed And Polilshed) In Steps, Jambs, Pillars, Window-Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In Wite Cment (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over 15 Mm Thick Screed Bed In Cement Mortar 1:6 All As Specified. , Material And Labour For Granite 20Mm Thick (Of Any Type) Work (Table Rubbed And Polilshed)For Wall Lining (Veneering To Wall) 12Mm Thick In Cement Mortar (1:3) And Pointing In Wite Cment (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over 10 Mm Thick Rendering In Cement Mortar 1:3 All As Specified. , Supply And Fix 2Nd Class Hard Wood, Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue, Pinned At Joints Complete All As Specified And Directed , Supply And Fix 30Mm Thick Second Class Hard Wood Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauge Etc With Plain, Chamfered Or Rounded, Mitred Beads (With Sash Bars) For Securing Glass Etc, Sizes Of Members Of Shutters All As Specified In Ssr Part-I Section 8 Clause 8.24 (B) Complete All As Specified And Directed. , Supply And Fix 35Mm Thick 2Nd Class Hw Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc.Divided Into Squares, With Plain,Chamfered Or Rounded,Mitred And Rebated Sash Bars,Any Numbers, Edges Of Framing Plain,Chamfered Or Rounded. Fitted With Cut And Mitred Beads For Securing Glass,Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats Complete All As Specified And Directed. , Supply And Fix 30 Mm Thcik Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified And Directed. , Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix 100 Mm Size Stainless Steel Butt Hinges, Complete All As Specified And As Directed. , Supply And Fix 75 Mm Size Stainless Steel Butt Hinges, Complete All As Specified And As Directed. , Supply And Fix 200 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Extruded Aluminum Alloy Handles, Fabricated Type, Anodized Complete All As Specified And As Directed , Supply And Fix 100 Mm Extruded Aluminum Alloy Handles, Fabricated Type, Anodized Complete All As Specified And As Directed , Supply And Fix 300 Mm Long Aluminum Alloy Anodised Sliding Door Bolt With Hasp, Staple (Bolt Type) And Fixing Clips Of Steel, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminum Alloy Complete All As Specified And As Directed. , Supply And Fix Stain-Less Steel Wire Cloth, 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40 Mm And Fixed With Stainless Wire Staples Complete All As Specified And As Directed. , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Box Type Steel Windows With Side Hung Shutters Both Mosquito Proof And Glazed Shutter Including Projecting Type Hinges With Steel Handle And Steel Peg Stay With Glazing Bars And 12 Mm Square Bar Or Ground Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And As Directed. , Supply And Fix Steel Ventilators With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete All As Specified And As Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete All As Specified And As Directed. , Material And Labour For Mild Steel Small Articles Such As Clamps, Hold Fast, Wind Ties, Bends, Anchorage Plate, Clamps For Holding Rwp, Brackets, Suspenders For Ceiling Etc Conforming To Fe-410-0 Or Fe-310-0 Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed Note: To Be Executed For Provison Of Ridges And Hips, Valley Etc Complete All As Specifed And As Directed , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:4) Complete All As Specified And Directed. , Material And Labour For 60Mm Thick M-40 Grade Cement Concrete Coloured Interlocking Paver Block Any Shape And Size Conforming To Is 15658-2006 With Grey Cement And Pigment As Approved Laid Over And Including 25Mm Thick Sand Cushion And Joints Filled With Sand Complete All As Specified And Directed. , Material And Labour For 75 Mm Thick Plain Cement Concrete 1:3:6, Type C-1, (Using 20 Mm Graded Aggregates) As In Plinth Protection Etc, Finished Even And Smooth Without Using Extra Cement Complete All As Specified Including Joints Filling With Sealing Compound Grade A Complete All As Specified And Directed. , Material And Labour For 100Mm Thick Cement Concrete 1:2:4 Type B-2 (Using 40Mm Graded Stone Aggregate ) As In Flooring, Hardstanding Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate ) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm Thick, In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry & Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete Of Item All As Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8Mm Thick Area Of Each Tile Exceeding 0.18 And N.Exc 0.38 Sqm In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry & Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete Of Item All As Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exc 0.18 And N.Exc 0.38 Sqm , In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 10Mm Thick Screed Bed In Cm 1:4 Complete All As Specified And Directed. , Material And Labour Coloured/ Printed Glazed Ceramic Tiles 7Mm Thick Not Exc 0.15 Sqm In Area In Vertical Surfaces I.E. Dado, Skirting, Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, Laid Over And Including Screed Or Screed Bed 10Mm Thick In Cement Mortar 1:4, Complete All As Specified And As Directed. , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Material And Labour For 5Mm Thick Rendering On Fair Faces Of Brick Or Concrete Surface In Cm 1:3 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Make: Berger Weathercoat Anti Dustt Or Equivalent Of Asian Paint Or Nerolac) Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Ceiling Surface And Applying Three Coats Of White Wash Complete All As Specified And Directed. , Material And Labour For Preparation Of Old Distempered Surface Of Wall Including Cornices Etc. By Washing, Rubbing Down,Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salt And Trading Oil And Greasy Spots And Stopping Of Distempered Surfaces And Applying One Coat Of Acrylic Distemper Of Approved Shade On Surface Of Wall Complete All As Specified And Directed. , Material And Labour For Complete Removal Of Existing Treatment On Wall Surfaces By Scrapping, Washing & Rubbing Down Including Applying A Layer 1 Mm Wall Care (Putty) For Making The Surface Even & Smooth Etc Complete All As Specified. , Supply And Fix Sheet Glass 3.0 Mm Thick Ordinary Quality And Glazing With Oil Putty/Wooden Beads In Squares Not Exc. 0.50Sqm In Each Pane Complete All As Specified And Directed. , Supply And Fix 4 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty/Wooden Beads In Squares Not Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed , Material And Labour For Preparation Of New Or Previously Untreated Surface Of Wood Or Wood Based Materials Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer All As Specified. , Material And Labour For Preparation Treating Small Articles Such As Stop, Covers Gully Grating, Holdfasts, Ends Of Post Backs Of Chowkats, Etc. Area N.Exc 0.50 Sqm Each And Applying Tar Or Coal Tar Black Paint To Back Of Chowkats. , Material And Labour For Preparation Of Old Painted Surface Of Wood And Wood Based Materials By Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salt And Trading Oil And Greasy Spots Of Any Discription, Not Otherwise Described, Over 10Cm In Width Or Girth And Applying One Coat Of Synthetic Enamel Paint, White Or Tinted Complete All As Specified And Directed. , Material And Labour For Preparation Of Old Painted Surface Of Steel And Iron By Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salt And Trading Oil And Greasy Spots Of Any Discription, Not Otherwise Described, Over 10Cm In Width Or Girth And Applying One Coat Of Synthetic Enamel Paint, White Or Tinted Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 15Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 20 Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Hand Basin White, Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Pvc Waste Coupling And 32 Mm Dia Pvc Waste Pipe Including Fixing Of Tap, Waste Fitting Etc Complete All As Specified And Directed. , Supply And Fix In Repair Bib Taps With Wall Flange 15Mm Bore, Fancy Type, Quarter/Half Turn, Brass Chromium Plated, Long Body With Capstan Head And Cup Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Accessories Complete All As Specified And Directed. , Supply And Fix In Repair 125 Mm Dia, Chromium Plated Swivel Type Shower Rose With 195 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15Mm Bore Iron Pipe All As Specified And Directed , Supply And Fix In Repair Bath Wall Mixer With 15Mm Bore (Dia) Spout, Chromium Plated With Long Bend Pipe For Over Head Shower Including Flanges Complete All As Specified And As Directed. , Supply And Fix In Repair Pillar Taps, Cast Copper Alloy, With Capstan Heads, Fancy Type, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered ‘Hot Or ‘Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe 15 Mm Bore Complete All As Specified And Directed. , Supply And Fix In Repair Cp Stop Valve/Angle Valve 15 Mm Bore, Fancy Type Cromimum Plated With Long Shank And Cup (Concealed Type), High Pressure Crutch Or Butter Fly Handle Screwed Both Ends Screwed For Iron Pipe Or For Unions Complete All As Specified And Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 1000 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places With Fittings And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 500 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places Complete And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix Ball Valves 20Mm Bore Dia Of Pipe High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed (Minimum Weight 20Mm-210Gms). , Supply And Fix In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Supply And Fix In Repair Pvc Valve, Symphonic Action Type, Flushing Cistern 10 Liters Capacity Low Level White With Inlet ,Ball Valve ,Float And Handle Including Brocket Complete All As Specified And Directed By Engineer In Charge , Supply And Fix 110Mm Dia Pvc (Swr) Pipes, Presure Rate Having 6 Kgf Single Socketed In Any Length With Rubber Ring Joints And Laid In Trenches As In Waste/Soil Pipe Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Complete All As Specified And As Directed. , Supply And Fix 75Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Or Floor Complete All As Specified And As Directed. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 75 Mm Bore Complete. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 110 Mm Bore Complete. , Supply And Fix Pvc Vent Cowls Of 110Mm Dia Etc Complete All As Specified And As Directed , Supply And Fix Pvc Vent Cowls Of 110Mm Dia Etc Complete All As Specified And As Directed , Supply And Fix In Repair Vitreous China Wash Down Water Closed Pan (Pedestal Pattern) With P Or S Trap White, Including Connection To Trap And Cistern, Flush Pipe Including White Plastic Water Closet Seat Cover, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Making Good Disturbed Surface Of Floor Complete All As Specified And Directed. , Supply And Fix, In Repair Vitreous China Wash Down Water Closet Of Orissa Pattern Size 580 X 440 Mm White With Integral Foot Rests Including Removing Filled Lean Concrete From Sunken Portion And Putting Of Lean Concrete After Treatment Of Sunken Slab, Connection To Trap And To Flushing Pipe Etc Complete And Making Good To Floor Complete All As Specified And Directed. , Supply And Fix In Repair Plastic Water Closet Seat Cover, White, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Fixed Wc Pan Complete All As Specified And Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area N.Exc. 1.5 Sqm Including Builders Hardware Each Complete All As Specified And As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each Including Builders Hardware Complete All As Specified And As Directed. , Taking Down Shutters Of Any Description N Exc 1 Sq. M Each Removing To Store All As Specified. , Taking Down Shutters Of Any Description Exc 1 Sq. M And N Exc 2 Sq. M Each Removing To Store All As Specified. , Dismantling, Floor Hearth Or Wall Tiling Inclduing Cement Mortar Bedding And Removing Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Or Cement Lime Mortar , Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. , Demolition And Breaking Up Drain Waste Pipes (Sgsw, Ac Or Rcc, Ci ) Of Internal Dia 75/110 Mm, Set In Cement Mortar In Any Position Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc. 15 Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc. , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Trusses Etc Complete All As Specified. , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
3.
Water Resources and Irrigation #11491318 AOC
Repairs To Electro- Mechanical Items And Civil Works In Gandhinagar L.I.Scheme On Tungapadu Vagu Near Gandhinagar (V), Damaracherla(M), Nalgonda District (5Th Call).-Excavation for Structures- Mechanical Means ( Data adopted from MORTH) Earth work in excavation in all kinds of soils of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material Depth upto 3 m Excavation in ordnary rock (including HDR) without blasting including boulders above 0.3 m upto 0.60 m dia. for foundations of canal cross drainage and other appurtenant structures and placing the excavated stuff neatly in specified dump area or disposing off the same as directed etc.,complete with initial lead upto 50m and initial lift upto 3m. Providing & constructing Sand filling below foudation including cost of all materials,machinery, labour, watering, ramming etc., complete with initial lead upto 50 m and all lifts. Providing and laying insitu vibrated M-10 ( 28 days cube compressive strength not less than 10 N / sq mm ) grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates for piers and abutments including cost of all materials, labour, machinery, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete with initial lead upto 50 m and all lifts.Note: If water is to be brought from other place add only lead charges @ 500 ltr / cum. (Cement content: 220 kg / cum with use of super plasticiser(0.4% by wt. of cement), CA : 0.90cum, Blending Ratio of CA--50:30:20, FA : 0.40 cum) Providing and laying insitu vibrated M-15 ( 28 days cube compressive strength not less than 15 N / sq mm ) grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates for sub-structure / super- structure works including cost of all materials,machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position,levelling, vibrating, finishing, curing etc., complete with initial lead upto 50 m and all lifts.(Cement content: 280 kg / cum with use of super plasticiser(0.4% by wt. of cement),CA : 0.80cum, Blending Ratio of CA--65:35, FA : 0.45 cum) Manufacture, supply and Delivery of R.C.C. Socket and Spigot pipes conforming to B.I.S. 458/2003 at ex-factory (rate per meter of effective length ) including conveyance and Laying and Jointing etc. (500 mm Dia) Manufacture, supply and Delivery of R.C.C. Socket and Spigot pipes conforming to B.I.S. 458/2003 at ex-factory (rate per meter of effective length ) including conveyance and Laying and Jointing etc. (400 mm Dia) Supply and fixing of Mild Steel works including all materials and labour charges like cutting, welding , bending etc for finished item of wok Supply and fixing of Structural Steel including all materials and labour charges like cutting, welding , bending etc for finished item of wok Surface cleaning of metal surfaces by chemical cleaners and then by hand and power tool cleaners and removing dust. After cleaning,applying primary coat with one coat of Zinc rich epoxy primer to a thickness of 40 microns ,followed by finishing coats 2 coats with Solventless Coal tar epoxy with material, labour and all accessories with all leads and lifts CRS Masonry in CM (1:3) 1st Sort Hot dipped Galvanized Iron Chain link mesh 8 gauge - (4.0 mm) as per IS:2721-1979: 2 x 2 (50 mm x 50 mm) - 8 Gauge Supply and erection of 0-500V Digital Volt meter on exisiting panel boardincluding connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMENS. Supply and erection of 0-100 / 200 / 400 / 600 /1000 Digital Ammeter of size 96x96mm on existing panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMEN Supply and fixing of Three phase Electronic energy meter, 240 V AC, 50 Hz as per IS 13010 upto 40 A range with 200% overload capacity complete with connections etc., complete on the existing board.MAKES : CONZERVE / ELMEASURE/ MECO/HPL/ HAVELLS Supply and erection of LED indication lamps on the existing panel board,including connections etc., complete.Makes : L&T / C&S / SALZAR / HPL MAKE. Supply and erecting porcelain Pin type insulator suitable for 11KV line with suitable hardware on existing cross arms. Filteration of transformer oil as per ISS specifications filters to di electric strength above 40 KV at site. Transformer oil tested as per IS-335 - 1972 (per Ltr) Supply of heavy duty long barrel aluminium lugs confirming to I.S specifications suitable for 400 Sq.mm cable etc complete with nuts,bolts and washers.Makes: DMI / Jainson / Dowels or equivalent make as approved by the department Supply of heavy duty long barrel Aluminium lugs confirming to I.S specifications suitable for 240 Sq.mm cable etc complete with nuts, bolts and washers.Makes: DMI / Jainson / Dowels Supply and erecting approved make 11KV, 5KA metal oxide lightning arrestors suitable for 11 KV supply with necessary materials on existing cross arm. Supply of 400A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL / Havells / Siemens / Indo Asian. Supply and fixing of 250A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL /Havells / Siemens / Indo Asian Supply & Fixing of D.O.L Starter 250V, Single phase, 50Hz. With SS enclouser comprising of contactor with bi-metallic relay with necessary push buttons, etc.complete suitable for 5 HP Motor Makes: Siemens / Crompton / L&T / BCH. Supply of 32A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL / Havells / Siemens / Indo Asian. Carryout routine maintenance, servicing and testing of 630A to 1000A L.T. ACB by cleaning fixed contacts ,moving contacts and arc chutes including servicing and putting the ACB in perfect working condition after getting all relay and ON ,OFF mechanism etc done with only manufacturing companies Supply and erection of approved make 11 kV Outdoor type gang operated Air break switch of 400 A capacity with 3 post pin type insulator per phase, mounted in Horizontal/Vertical position with necessary channels on cross arms with necessary channels on cross arms with adequate length of C class GI pipe for operating handle provided with Lock & Key at suitable height from ground level with necessary clamps. Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). Carryout routine maintenance and servicing of LT.Cubical panel board having approximately 15 to 22 Nos of switches cleaning with power brower and servicing the contacts, tightening the connection of incoming and outgoing cables, and clicking the operating.machanism for smooth functioning of switches and putting them in smooth working condition. Supply and fixing of 15.0 KVAR rating capacitor duty Contactor Supply and fixing of 25.0 KVAR rating capacitor duty Contactor Supply and Run of 50 mm x 6mm G.I. strip including cost of all accessories and labour charges etc., complete Supply and erection of Panel mounting cubical type 32A TPN 415V, 50 Hz. switch disconnector fuse unit complete with front drive mechanism with door inter lock,padlocking arrangement etc., complete with fuse links on existing control panel.Makes : L&T / SCHNEIDER / C&S / ABB / SIEMENS Supply,fixing and transportation of 43 / 45 W +/-10% (>=4500 Lumens) LED Street light Body made of high grade pressure die – cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >100 lumens/watt, with Ingress protection IP66, Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor must furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA / Capart / Fortune Arrt / FIEM / Panasonic / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Supply of 240 Sqmm 3.5 Core XLPE insulated, 1100V grade armored aluminum cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable / Beljin / Ollivin Supply of 400 Sqmm 3.5 Core XLPE insulated, 1100V grade armored aluminum cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable / Beljin / Ollivin Supply and erection of LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing panel including connections etc., complete. MAKE : KAPPA Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I ( Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick masonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through flange with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II) Supply of 11 KV/22 KV Hand gloves S & F Bronze Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 40 mm NB Size. S & F Bronze Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size. S & F GI Union 40 mm nominal size 1st Quality S & F GI Union 25 mm nominal size 1st Quality Supply of Grease Supply of Packing Rope to the work site. Supply of Grease gun of 1 kg capacity. Complete dismantling of DV 40x40 vacuum pump, over hauling with replacement of pump bearings-2 Nos. Pump shaft gun metal bushes , pump glands, reconditiong of port plates, impeller lock nuts , studs, wheel bearing grease assembling of pump erection on base plate, correct alignment of pump and motor, successful trial run at site including cost of materials , labour charges, transportation charges of pump from scheme to workshop and vice versa and all other incidental charges etc. complete Supply and fixing of PH316 UNIQUE make coupler made of rubber Supply and fixing of Packing Studs to the work site including labour charges, etc., as directed by Engineer- in- Charge. Supply and fixing of Star and Delta Contactor in panel board, L&T MNX 265 Complete dismantling of (300mm-500mm dia) NRV. overhauling, replacement of wornout parts like spindle nut facing of shutter providing new bolts and nuts, rubber packing , assembling of valve including cost of materials , labour charges, transportation charges from scheme to workshop and vice versa and all other incidental charges etc. complete Complete dismantling of (300mm-500mm dia) Sluice Valves. overhauling, replacement of wornout parts like spindle nut facing of shutter providing new bolts and nuts, rubber packing , assembling of valve including cost of materials , labour charges, transportation charges of pump from scheme to workshop and vice versa and all other incedental charges etc. complete Complete repairs to 100mm dia Aircushion Valve and fixing including all other incidental charges etc. complete Complete repairs to 600mm dia Zero velocity valves and all other incidental charges etc. complete Complete repairs to 200mm dia Air Valves and all other incidental charges etc. complete Repair of 600mm Dia Expansion joint in Pressure main Complete Dismantling,Overhauling of WPIL make HCF pump run by 210 HP by replacing with new sleeves, bearings,impeller rings, chucknuts etc and aligning the pump true to the alignment of motor and successful trial run at site including transportation charges from site to work shop and vice versa Rewinding of Electric motor of 210 HP, 3Phase up to 1485 RPM squirrel cage induction motor with copper wire, for required IR values including minor repairs, hot air blowing lubrication of ball bearings, bush bearings and erection on base plate, correct allignment of pump and motor, testing of motor for original speed etc. trail run at site,including cost of materials, labour charges transportation charges of motor from scheme to workshop, workshop to scheme and all other incidental charges etc. aas directed by Engineer in charge. Supply and fixing of new Terminal Plate for 210 HP Motor ABB make Supply and fixing of 6316 C3 - 6319 C3 bearings set to the motor Supply and fixing of Thermal Overload Relay- CT ratio set (Make: L&T) MN12 9-15 Amps Supply of Timer ET 100 (L&T) Complete Servicing of 11 KV, 630 A, 25kA Outdor type Load Break switch replacing of damaged outgoing/incoming insulators, servicing the spring charge mechanism, Tighten the bus bar connections, Replacement of Indicator lamps and putting the Load Break Switch in perfect working condition after getting all relay and ON,OFF mechanism etc done with only manufaturing companies Painting to Transformer Yard pole structure after duly cleaning existing metal surfaces Supply and fixing Panel board lock Internal wiring inside Pump House 6 mm rubber flange for packing
Contract Date: Ref. Documents Contract Value : 23.60 Lakh
Government Departments No of Bidders 1
4.
Defence #11478095 Technical Bid
Tender For Provision Of Certain Revenue And Minor Work At Age B/R Ii Under Ge(N) Patiala=- 1 Dismantling, Floor, Hearth Or Wall Tiling Including Cm (Bedding (But Not Backing), Removing Serviceable Tiles To Store & Rubbish Off The Premises Complete All As Specified And Directed 2 M&L For Single Charge, Vitrified, Stain & Scratch Resistant, Premium Quality Coloured Tiles Area Of Each Tiles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm, In Floors Etc Mm And 8-10 Mm Thick, In Any Pattern Of Light & Dark Tiles As Approved, Laid Over 15 Mm Thick Screed In Cm (1:6) Epoxy Cartridge Tile Grout Using Filling The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour,Complete All As Specified And Directed. 3 All As Per Item No 2 Above But As In Skirting Over 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. 4 M&L For Ceramic Glossy Finish, Joint Free Premium Quality Coloured Tiles 600 X 300 Mm And 8-9 Mm Thick, In Any Pattern Of Light & Dark/Highlighters Tiles Etc As Approved, On Vertical Surfaces Such As In Skirting/Dado Etc, Set And Including 10 Mm Thick Rendering In Cement Mortar (1:4) And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 5 M & L For 15 Mm Thick Artificial Granite (Of Any Type) Work Steps, Jambs, Pillars, Window- Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. Including Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishes Complete All As Specified. 6 Providing And Laying Premium (1St) Quality Straight Edge, Ceramic Tiles Exterior Grade Scratch Resistance Of Size 300X300X7 To 8 Mm Thick In Floors Etc. In Any Shade And Design/Pattern Of Light & Dark Tiles Etc Set And Including 15 Mm Thick Rendering In Cement Mortar (1:6) And Pointed In White Cement With Pigment To Match Complete All As Specified. 7 Taking Up Or Down Existing Steel Tubing And Connections, 15Mm Bore Complete All As Specified. 8 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 15Mm Bore Incl Fittings Complete All As Specified And Directed. 9 Taking Up Or Down Existing Steel Tubing And Connections, 20Mm Bore Complete All As Specified. 10 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 20Mm Bore Incl Fittings Complete All As Specified And Directed. 11 S&F In Repair Angle Stop Cock With Wall Flange 15Mm Cast Copper Alloy, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No-Fon-40053Pm Or Equivalent In /Hindware/Kohlar. 12 S&F In Repair 15 Mm Bore Bib Cock With Wall Flange, Cast Copper Alloy, Chromium Plated, Fancy Type With Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No Opp-15037Pm Or Equivalent In/Hindware/Kohlar. 13 S&Fin Repair Brass Chromium Plated Basin Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar Cat Part No Orp-10011Bpm Or Equivalent In /Hindware/Kohlar 14 S&F In Repair 15Mm Cp Connection 600Mm Long Including Washer And Brass Nuts All As Specified. 15 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 16 S&F In Repair Counter Top Wash Basin Of Size 600 X465Mm With Wash Basin Cabinet Size 600X455X600Mm Including Bottle Trap , Brass Waste Fitting Complete All As Specified. Make:-Cera/Hindware/Jaguar 17 S&F In Repair Toilet Roll Holder Stainless Steel Flap All As Specified. Make- Jaquar Cat Part No Can-1153S Or Equivalent In /Hindware/Kohlar 18 S&F In Repair Towelrack 600Mm Long With Lower Hanger (Stainless Steel) All As Specified.(Make: Jaquar Cat Part No Acn -1181S Or Equivalent In /Hindware/Kohlar 19 S&F In Repair Soap Dispenser With Glass Bottle (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1135N As Equivalent /Hindware/Kohlar 20 S&F In Repair Soap Dish Holder With Glass (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Akp -35731P Or Equivalent In /Hindware/Kohlar 21 S&Fin Repair Towel Ring Square With Round Flange (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1121N Or Equivalent In /Hindware/Kohlar 22 S&F In Repair Healthfaucet With 1Mtr Long Easy Flex Tube In Chrome Finish And Wall Hook Of 15 Mm Bore With Cp Pipe Complete Set Of Make -Jaquar Cat Part No Ald - 565 Or Equivalent In Parryware/Prayag 23 S&F In Repair Looking Mirror 5Mm Thick Size 3.5X3.5 Feet Incl Stud And Fastners Complete All As Specified And Directed. 24 S&F In Double Arm Wall Mounted Reversible Plain/Magnifying (X3) Pivotal Mirror All As Specified. Jaquar Cat Part No Acn -1193N Or Equivalent In /Hindware/Kohlar 25 S&F In Repair Glass Shelf Corner With Bracket Of Size 225Mm X 225Mm Thickness Of Glass 6Mm) With Cp Brass Railing And Brass Screws.Make- Jaquar Cat Part No Acn -1173 Or Equivalent In /Hindware/Kohlar 26 S&F Grating Doom 125Mm Of Ptmt. 27 S & F In Repair Vitreous China Urinal Half Stall Type White (Excluding Flushing Cistern ) Including Waste Fitting, Waste Pipe Complete All As Specified.Make-Jaquar/Hindware/Kohlar 28 S&F Ms Work In Tubular/Pipe/Angle Sections For Frame Work For Roof, Vertical Poles, Rafters And Purlins Including Washer Etc Complete All As Directed. 29 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. ( Design Of Sheet As Mangalore Tiles Pattern In Red Colour ). 30 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. 31 M & L Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Incl Preparation Of New Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. 32 M&L 25Mm Thick Factory Made Coloured Interlocking Designer Polished Floor Tiles (Ultra Pattern) Of Grade M-35 Of Shape And Size As Directed,And 100Mm X 100Mm Size Tiles Piece On Every Joint Of Tiles Flooring Laid Over & Including 20Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed . Note: Sample Shall Be Got Approved From Ge Before Commencement Of Work 33 S&F In Repair Stainless Steel Drapery Rod Of 20 Mm Inner Dia (In Lengths As Directed) Of & Including Decorative Finial At Both Ends And Pair Of S S Steel Brackets Fixed At Both Ends With Pvc Rawl Plug & Steel Screws On Walls/Beam, (Victorian Design)All As Specified & As Directed. Make -Sample Can Be Seen In The Office Of Engg-In-Charge For Checking And Quoting The Same 34 Demolition Of Cement Concrete Un -Reinforced In Ground Floors And Pavings N.Exc 15Cm Thickness Complete All As Specified. 35 M& L For 25Mm Thick Pcc 1:2:4 Type Bo Using 12.5 Mm Graded Stone Aggregate As In Floor Complete As Specified And Directed. 36 S & F 75 Mm Dia Pvc ( Swr ) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified. 37 S & F Floor Door Stopper Of Aluminium Alloy And Tongue, Anodised With Hard Drawn Steel Overall Length Of Cover Plate 140Mm.As In Repairs Complete All As Specified. 38 Dismantling Of Wall And Ceiling Board(Fiblre, Pulp, Insulation Etc) Any Thickness Including Cover Fillets Complete All As Specified And As Directed. 39 S & F Powder Coated Aluminum Alloy Interlocking Snap Grid Frame Work For False Ceiling Size 600Mm X 600Mm Consists Of Main Tee Runners Of Size 38Mm X 38Mm X 1.5Mm And Cross Tee Of Size 38Mm X 38Mm X 1.5Mm, Spaced Between The Main Tee At 600Mm Centre To Centre To Form A Grid Of 600Mm X 600Mm Complete All As Specified And As Directed And As Per Manufacturer. Instruction. 40 M & L For 4Mm Thick Non Asbestos Fibre Cement Building Boards Of Make E Board Classic Designer Board (Cascade Or Occenic) Of M/S Everest Industries Ltd Or Equivalent As Approved, By Ge Fixed Or Laid/ Inserted To Timber/Gi/Aluminium Framework With Complete All As Specified And As Directed. 41 Taking Down Cement Mortar Plastering On Brick Or Stone Walls, Etc. Including Raking Out Joints,Hacking For Key,Scrubbing Down With Water, Etc Complete All As Specified And As Directed. 42 M&L For Rendering 15Mm (In Two Layers 10Mm+5Mm) Thick Plaster In Cm (1:4) On Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 43 M&L For Rendering 5Mm Thick Plaster In Cm (1:3) On Faces Of Brick Work Or Concrete On Surfaces Of Ceiling, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 44 Complete Removal Of Existing Treatment Including Washing Rubbing Down And Stopping Of Painted Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 45 M&L For New Plaster Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 46 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 47 M & L For Cement Concrete As Pcc 1:5:10 Type E-2 Using (40Mm Graded Stone Aggregate) As Foundations,Filling And Mass Concrete Complete All As Specified. 48 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 49 Demolition Of Brick Work Or Stone/Boulder Masonary, Laid In Cement Mortar Or Cement Lime Mortar Complete All As Specified. 50 M&L Brick Work, Straight Or Curved On Plan N.Exc 6M Mean Radius In Cm 1:6 Using Old Size Brick Complete All As Specified. 51 Taking Down Chowkat Or Frame With Shutters (With Out Taking Off Shutter From The Frame ) Not Exceeding 1.5 Sqm Each As Directed By Engineer-In-Charge. 52 S&F For Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door Frames/Chowkhat Comprising Of 100 Mm X 65 Mm Size, Applying Pvc Solvent Cement And Screwed With Full Body Threaded, Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/Cum And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With Mild Steel Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete All As Specified And As Directed By Engr-In-Charge. 53 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Solid Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 54 S&F Stainless Steel (304 Grade) Finished Butt Hinges 125Mm Complete All As Specified And Directed 55 S & F Extruded Brass Handles, Fabricated Type Polished 150 Mm Complete All As Specified. 56 S & F Brass , Barrel Tower Bolts, With Cast Or Sheet Barrel And Rolled Or Cast Bolts And Fixed 200 Mm Complete All As Specified. 57 M&L For 250Mm Long Brass, Sliding Door Bolt Withsand Or Die-Cast Brass Hasp, Staple (Bolt Type) And Fixing Bolt With Rolled Or Drawn Brass Bolts And Fixed Complete All As Specified And As Directed. 58 Dismantling Pvc Pipes With Fittings Upto 75Mm To 110Mm Dia Complete All As Specified And Directed By Engr-In Charge.. 59 S&F For Pvc (Swr) Pipe 110 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 60 S&F For Pvc (Swr) Pipe 75 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 61 S&F For Pvc (Swr) Bends With Access Door 110 Mm Dia Complete All As Specified And As Directed. 62 All As Per Item No 61 Above But 75 Mm Dia. 63 S&F Pvc (Swr) Plain Bend 110 Mm Dia Complete All As Specified And As Directed. 64 S&F Pvc (Swr) Plain Bend 75 Mm Dia Complete All As Specified And As Directed. 65 S&F Pvc (Swr) Branch Piece Single Or Double T Equal Or Unequal With Access Door 110 Mm Dia Complete All As Specified And As Directed. 66 All As Per Item No 65 But 75 Mm Dia. 67 S&F Pvc (Swr) Vent Cowl 110 Mm Dia Complete All As Specified And As Directed. 68 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50 M And Making Good Surface 69 M&L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc. And Making Good, Cutting Not Exc 10 Cm Girth All As Specified. 70 Taking Down Carefully Existing Points Wiring On Surface Conduit/Concealed Conduit Including Conduit From Surface And Expect Conduit In Concealed Wiring For Light/Fan/Socket/Power/Bell From Wall & Roof Along With Fitting And Fixtures Such As Switches, Sockets, Ceiling Roses, Batten Holders, Unserviceable Light Fittings, Pieces Of Wires, Gutties, Conduit, Wooden Boards Etc Removing Materials To Store For Keeping In Safe Custody Of Contractor For Which The Credit Has Been Considered Under Schedule Of Credit And Making Good The Disturbed Portion Of All Floor, Ceiling Etc All As Specified And Directed. 71 M & L For Point Wiring With 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor For One Light/Fan/Bell Point In And Including New Pvc Rigid Non Metallic Concealed Conduit 19/20 Mm Dia, Medium Duty, Isi Marked To Be Terminated In Pressed Steel Terminal Boxes With Pvc Modular Top Cover Plates Of Suitable Size For Mounting Of Modular Type Switches/Sockets/Regulators Including 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Earth Continuity Conductor Controlled By One Switch And/Or One Regulator Complete Including Cutting Chases And Making Good The Surfaces In Cm 1:3 And Finishing The Surface As Per Existing Treatment All As Specified And Directed By Engr-In-Charge.Notes: (I) Cost Of Pressed Steel Terminal Boxes And Modular Top Cover Plate Shall Be Included In Point Wiring. (Ii) Wiring Shall Be Done As Per Colour Code In Is For Phase, Neutral And Earth.(Iii) -Cost Of Eye/Bottle Thimbles Used For Connection In Switches/Sockets & Mcbs In Dbs Shall Deemed To Be Included In The Unit Rate Quoted For This Item. 72 All As Per Sl Item No 71.00 Above Herein Before But One Socket Out Let 5 Pins 5 Amp On The Same Board With Other Switches Complete All As Specified And Directed. 73 All As Per Sl Item No 71.00 Above Herein Before But For One Socket Out Let 5 Pins 5 Amp On Independent Board Complete All As Specified And Directed. 74 All As Per Item No71.00 Herein Before But 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor Incl 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Copper Earth Wire For Switch Socket Combination 3 Pin 15 Amps On Independent Board. 75 S & F In Replacement Of Modular Switch 1 Way, 6 Amps, 1 Module, 230 Volts Complete All As Specified. 76 S & F In Replacement Of Modular Switch 1 Way, 16 Amps, 1 Module, 230 Volts Complete All As Specified. 77 S & F In Replacement Of Modular Socket 5 Pin 6 Amps, 2 Module 230 Volts Complete All As Specified. 78 S & F In Replacement Of Modular Socket 5 Pin 6 &16 Amps, Combination Type 2 Module Complete All As Specified. 79 S & F In Replacement Of Modular Fan Regulator Step Type, 120 Watts, 2 Module Complete Fixed As In Repair All As Specified. 80 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 81 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Green Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 82 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Red Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 83 Supply And Fix Surface/Recess Mounted Led Luminaire 36 Watt Cool White 4000-5000K Suitable For Gridd Celling Cutout Dimensions: 2X2 Ft. Incl Connecting With Twin Core Copper Wire From Ceiling Rose To Fitting, Fixture Size: (Lxwxh) In (595X595X65) Mm Incl Lamp And Driver All As Specified & Directed. 84 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 18/20W 6500K Of Capacity ,20 Watt,4 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 85 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 86 Supply And Fix Mirror Light With Linear & Compact 12 W Mirror Light With Decorative Grey End Caps, Polycarbonate Body And Ribbed Opal Diffuser Of Capacity 9 Watt Complete All As Specified And Directed By Engr-In-Charge. 87 M & L For Sub Main Wiring With Two Single Core 4.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 4 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2 Runs Of 4.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 4.00 Sqm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note2 : Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces, Cutting Not Exc. 10 Cm Girth . (Iii) Taking Out/Down Existing Unserviceable Sub Main Wiring. 88 Taking Down And Refixing Of Ceiling Fan After Supply And Replacement Of Rubber Reel, Round Cover Plate Of Size 6 Inch Of Ceiling Fan Complete With Ms Split Clamp Two Nos, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 89 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 250 Mm Sweep 900 Rpm Engineering Thermoplastic Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Louver Complete All As Specified And Directed By Engineer-In-Charge. 90 Material And Labour For Making Hole Of Suitable Size For Exhaust Fan 250 Mm/ 300Mm Sweep In Wall For Grouting And Making Good The Surface Complete All As Specified And Directed By Engr-In-Charge. 91 Supply And Fixing Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With Mcb Spn 32 Amps, Complete All As Specified And As Directed By Engineer-In-Charge. 92 S&F Poly Coated Gi Frame Work As In Grid For False Ceiling Comprising Of Protected Gi Perimeter Channel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleves And Screws At 450Mm Centre To Centre/Intermediate Chaqnnel 0.9Mm Thick Having To Equal Flanges Of 15Mm Each And Web Of 45 Mm Suspended From Soffit And Approx 900Mm Centre To Centre With Gi Cleat And Steel Expansion Fasterners With And Including Ceiling Section (Not Exc 1.2 Metre Length) Of 0.55Mm Thickness Having Kurled Web Of 50Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel With Connecting Clips Acorss The Intermediate Channel At 457Mm Centre To Centre And Hangers 6Mm Dia Gi (Upto 1200 Mm Length Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X3Mm Size 60Mm Long Complete With And Including 7Mm Thick Pvc Laminated Gypsum Tiles Of Size 595X595Mm Complete All As Specified & Directed 93 M&L For Complete Removal Of Existing Surfaces Of Walls Including Cornices, Pillasters Etc, And Applying Two Coats Of Obd Over And Incl A Coat Of Interior Wall Primer Over Wall Care Putty Complete All As Specified And Directed. 94 M&L For Complete Removal Of Existing Treatment On Walls And Applying 02 Coats Of Exterior Weather Emulsion Paint To External Walls/Rcc Surfaces/Soffits Of Chajjas/Roof Projections/Cantilevers/Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer And Over Wall Care Putty Complete All As Specified. 95 S&F Stainless Steel Tubing Of 25 Mm Dia Chromium Plated Min. 1.0 Mm Wall Thickness As In Curtain Rod Complete Incl S&F 02 Nos Stainless Steel Brackets/Finials Fency Type, Stops Fixed With Ss Screws Etc All As Specified & Directed.Note : For The Purpose Of Mesurement And Payment Running Length Of Curtain Rod Only Shall Be Considered. 96 Taking Down Chowkhats Or Frames Of Any Description Exc 1.5 Sqm And N. Exc. 4 Sqm Each (Without Taking Off Shutters From The Frame) Including Cutting Hole To Size For Receive Fresh Pcc Of Hold Fast And Making Good The Disturbed Surface Same Complete All As Specified And Directed. 97 S&F Factory Made Pressed Steel Frames Made Of Ms Sheet Of 1.20 Mm Thickness For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified,Size 125X60Mm 98 M&L Pcc 1:3:6 Type C-0 In 12.5 Mm Graded Stone Aggregates Hold Fast Fillinng Inside Frame & Hold Fasts Etc Complete All As Specified 99 S&F Factory Made Flush Shutters 35Mm Thick Ply Construction, Bwp Confirming To Is 2202, Solid Core Construction, With Block Board Core And Plywood Face Panels Commercial Type On Both Sides With 6Mm Thick Lipping Frame To Match Including Supply And Fixing Following Items :(A) Mild Steel Butt Hinges 125Mm - 3 Nos. Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos. Per Leaf(D) Stainless Steel (804 Grade) Finished Sliding Bolt 250 Mm - 1 No. Per Leaf(E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 100 S&F 35Mm Thick Glazed And Skelton Shutters Of 2Nd Class Hard Wood (Factory Made) Open Rebated And Divided To Receive Glass, Gauze Etc (Without Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc Size Of Members Of Shutter As Specified In Ssr-91 Pt-1 Section 8 Clause 8.20(A), Kiln Seasoned And Chemically Pressure Treated All As Specified Including Stainless Steel 304 Grade Wire Cloth (0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm) All As Specified And Including Supply And Fixing Following Items :(A) Stainless Steel (304 Grade) Finished Butt Hinges 125Mm - 3 Nos Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos Per Leaf(D) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16X250Mm - 1 No Per Leaf (E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 101 M&L For Two Coat Of Synthetic Enamel Paint (Finishing Coat) Over One Coat Of Pink Primer To New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Incl Prepration Of Surfaces Complete All As Specified And Directed. 102 S&F 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed. 103 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 104 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X35 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 105 S & F In Replacement Of Surface Mounted Led Bulk Head Luminaire Of Capacity 10 Watt With Abs Body & Polycarbonate Diffuser, Ip54 Inc Connection With ,With Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 106 Supply And Fix Lamp Holder Including Led Bulb 9 W Including Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 107 M & L For Sub Main Wiring With Two Single Core 6.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 6.0 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2(Two) Runs Of 6.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 6.00 Sqmm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note 2 :(I) Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces And Cutting Not Exc. 10 Cm Girth . (Iii) Including Taking Out/Down Existing Unserviceable Sub Main Wiring. 108 S & F In Replacement Of Sheet Metal Enclosure Db Tpn 4 Ways Double Door 415 Volts With 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables Complete With Ip-43 Protection Complete All As Specified And Directed By Engr-In-Charge 109 S & F In Replacement Of Mcb, Triple Pole & Neutral (Tpn) 10 Ka 240 Volts 40 To 63 Amp Capacity Fixing In Db’S Complete All As Specified And Directed. (Note: Mcb Should Be B Or C Curve As Directed By Engineer In Charge) 110 Supply And Fix In Replacement Of Sheet Metal Enclosure 8 Ways Double Door For Dbs When Mcbs Are To Be Used 240,Volts Including 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link All Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables With Ip43 Protection Complete All As Specified & Directed By Engr-In-Charge. 111 S & F In Replacement Of Mcb, Single Pole 240 Volts 6 To 32 Amp Capacity For Fixing In Db’S Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 112 Supply And Fix In Replacement Of Mcb , Spn, 240 Volts ,40-63 Amp For Fixing In Dbs Of Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 113 M & L In Replacement Of Unsv Earthing Complete With Galvanized Iron Earth Plate Electrode Of Size 600X600X6.0Mm , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Below Normal Ground Level) With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Bolts , Nuts , Check Nuts And Galvanized Iron Or Steel Including Earth Work In Any Type Of Soil, Charcoal Salt 15 Cm Around The Earth Plate 20 Mm Dia Watering Pipe Medium Grade 1.70 Mtr Long With A Plug At Top, Gi Protection Pipe Light Grade 15 Mm Dia From Earth Pit To Main Board Including Pcc Pit In Cement Concrete 1:2:4 Along With Ci Frame And Cover 10Mm Thick Duly Hinged To Ci Frame As Shown In The Electrical Plate No3 Of Ssr 2009 Part 1 Specification At Page 497. 114 Xlpe Insulated ,Screened, Pvc Bedded, Galvanized Steel Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sq Mm 4 Core Supplied & Laid In Replacement Complete All As Specified& Directed By Engineer-In-Charge. 115 Excavation In Trenches Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth For Laying Of Cables Including Getting Out In Any Kind Of Soil Complete All As Specified And Directed. 116 Returning Filling In Including Spreading, Levelling, And Well Ramming, In Layers Not Exceeding 25 Cm Each Layer Of Any Kind Of Soil. 117 Removing Surplus Excavated Material From Site Not Exceeding 50 Mtrs From Starting Point And Depositing Where Directed At Level Not Exceeding 1.5 Mtr Above The Starting Point. 118 Material And Labour For Sand Cushioning For Cables 8 Cm Below The Cable And 15 Cm Above With Dry River Sand In Trenches For Cushioning Of Underground Cable Line Including Spreading, Leveling, Well Ramming Completed All As Specified And Directed. 119 Cutting Of Hardstanding Floor/Wall For Laying Of Cable Including Matching With Suface By Using Cement Concrete All As Specified And Directed. 120 Supplying & Laying Factory Made Unreinforced Precast Concrete Cable Covers Class Lv Type 1, Flat, Size 250X150X40Mm Laid In Trenches As Protection To Cables Complete All As Directed By Engr-In-Charge 121 Material And Labour For Replacement Of Gi Tubing Light Grade 40 Mm Bore For Passing Through Cables Under The Floor ,Along The Wall Or Along The Pole Complete All As Specified And Directed. 122 Dismantling Of Stone Slab And Tiles Laid Bedded And Pointed In Any Mortar Description Or Thickness In Floors, Apron Etc Complete All As Specified. 123 M & L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick In Cm 1:6 For Laying Floor Finishes Complete All As Specified. 124 M&L For Virified Ceramic Light Shade Tiles 8 - 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc,Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Epoxy Cartridge Tile Grout Using Fill The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour. 125 All As Per Item No 124 But As A Skirting Incl. 10Mm Thick Rendering As In Back Coat Complete All As Specified. 126 M&L For 7 To 8 Mm Ant-Skid Ceramic Joint Free Premium Quality Coloured Tiles Area Of Each Tile Esc 0.06 Spm But Next 0.11Sqm, As In Floors Etc. In Any Pattern Ghe & Dark Tiles As Approved, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, In Floors Etc. Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 127 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Laid Over Cement Screed Base 15Mm Thick In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 128 Rounding To Edges Of Stone Slabs One Edge, Such As In Steps, Cooking Platform, And Other Similar Situations All As Specified. 129 Dismantling Water Tanks And Removing To Store Of Capacity Exc 500 & Not Exc 1000 Ltrs Complete All As Specified. 130 Supply And And Fixing, Hoisting Pvc Tank Of 1000 Ltr Capacity Including Supplied And Fixed 20Mm Dia Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed.(Minimum Weight 15Mm-142 Gms/20Mm-210Gms/25Mm-455 Gms/40Mm-690 Gms Float Valve Assembly Complete All As Specified And Directed. 131 S&F In Repair Wall Mixture Mixing Valves Incl. Three Joints To Steel Pipes Or Unions 15 Mm Bore Fancy Type Best Quality As Per Sample Approved By Ge Make-Jaquar Cat Part No Qqp-7217Pm Or Equivalent In Hindware/Kohlar. 132 S&F Pvc Cabinet 600X450Mm Overall Size With Looking Mirror Of Selected Qality Glass Mountedover Pvc Framing As Per Sample Complete Fixed In Repair Complete All As Specified. 133 S&F Stainless Steel Plate Rack Of Size Not Less Than 90Cmx75Cm(Wt N. Less Than 4 Kg) Fixed With Stainless Steel Screw Including Taking Out Old Unserviceable Wooden Plate Rack As Approved By Ge Complete All As Specified. 134 S&F In Repairs Chromium Plated Shower Roses With Swivel Joints 125 Mm Dia Size Incl Fixing To Gi Pipe/Union Fixed Make-Jaquar /Hindware/Kohlar. 135 M & L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6 Finished Even And Smooth ( Without Using Extra Cement ) With Sagol Finish On Plastered Surface Complete All As Specified And As Directed. 136 M&L For Preparation Of New Decorated Plastered Or Unplastered Surfaces Of Walls And Applying Two Coats Of Exterior Emulsion Over One Coat Of Primer And Over 2Mm Thick Putty For Levelling And Smoothening, Complete All As Specified And Directed. 137 M&L Preparation Of New Plastered Surface Of Walls And Applying Two Coats Of Oil Bound Distemper Over 1.5Mm Thick Wall Care Putty Complete All As Specified And Directed. 138 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 139 S&F Sinks With Drainage Board Made Of Stainless Steel Lmm Thickkitchen Or Laboratory With Plugs,Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. 140 S&F In Repair Brass Chromium Plated Sink Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar /Hindware/Kohlar 141 S&F Powder Coated Anodised Aluminium Frame For Doors, Windows Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. 142 S&F Frosted Glass 4.00Mm Thick Ordinary Quality And Glazing With Oil Putty In Square N.Exc 0.50Sqm In Each Panes Complete All As Specified And Directed. 143 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Sketon/Glased Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 144 S&F Factory Made Wpc Extruded Board Cnc Machine Cut Jali Fixed To Skelton Door As Per Approved Design Complete All As Specified And Directed 145 S&F Kitchen Cabinets Including All Fittings And Fixtures Incl The Follwing. (A) 19Mm Thick Plywood Of Commercial Block Board,Make: Kitply/Century Ply/ Green Ply(B) 1Mm Thick Commerical Lamination On Both Side Fixed To Black Board(Colour And Design As Approved)(C) Ss Pullout Basket Ss Finish Of Plain 15 X 20 X 6 (D) D Type Handle 100Mm Ss Finish(E) Pullout Basket Ss Finish Cutlery Wire Of Size 15X20X4 (F) 2Nd Class Hard As In Frame Work(G)Ss Channels For Pullout Basket As Required. (Note:- The Measurement Shall Be Taken From Front Elevation And Not Girthwise. 146 S&F Factory Made Upvc Brown Colour Door Shutter Made Of Extruded Profile With Wall Thickness Of 2.3Mm(+-0.2Mm) Door Profile With Hollow Section With Multy Chamber. Frame (60X62Mm),Sash(42Mmx67Mm).Sliding Interlock(One Verticle Length In Each Shutter)(45.5Mmx28Mm).Glazing Bead(24.5Mmx16Mm)Will Be Mittred Cut And Fusion Welded At All Corner.Including Drilling Holes For Fixing Hardware And Drainge Of Water Etc Am,.Making Arrangement For Fixing Of Hardware.Epdm Gasket,1.2+0.2 Mm Thick Galvanised Steel Frame(30Mmx21.5Mm).Sash (30Mmx18Mm)Profile To Be Inserted In Required Profile.Frame Will Be Finshed To The Wall With 8Mmx100Mm Long Fasteners.Hardware Touch Lockof Zinc Alloyed(Brown Powder Coated)Steel Roller System Including 5Mm Thick Glazing With Selected Quality Glass ,Aluminium Track And Bottom Rail For Two Track Sliding Fram,Wool Pine For Sliding Sash And Interlock. Note.The Unit Rate Coated By Contractor Includes Cost Of Glass And All Other Conncted Accessories,Net Opening Will Be Measured For Purpose.Make:H2O Window,Fenesta,Anuplast As Approved By Ge. 147 M&L For Rcc 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate In Any Situation Except Foundation Complete All As Specified And Directed. 148 S&F 10Mm Dia And Above Tmt Bars Cut To Length, Bend To Shape As Required Including Cranking, Hooking Ends & Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Complete All As Specified And Directd. 149 All As Item No 77 Here In Before But 5Mm Dia And Over Upto & Including 10Mm Dia In Stirrups, Spaces & Binder Complete All As Specified And Directd. 150 S & F Powder Coated Aluminium Window/Ventilator Shutters, Side Hung Type With Sash Bars, Including Necessay Joinery Cleats, Glazing Clips, Rubber Packing, Chowkats Aluminium Snap Beading, Screws, Suitable Handle Etc With And Including Sheet Glass Or Ordinary Glazing Quality Of 4Mm Thick And Incl Gi Wire Mesh 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 Mm , Size Of Side Rails , Top Rails , Bottom Rail 85X44.5Mm And Size Of Chowkat Frame 101.6X44.45Mm And Thickness Of Aluminium Member Shall Be 1.40Mm Thick Complete All As Specified. 151 S&F For Prelaminated Particle Board 18/19 Mm Interior Grade Prelaminated On One Side With Decorative Choice Lamination And Other Side Balancing White Lamination Fixed With Screw Timber Frame Work Including Dismantling Board All As Specified. 152 S&F In Repair Continuous (Paino) Hinges, Mild Steel, Bright Finish Or Electrogalvanised Width Of Flap (When Open) In 40Mm All As Specified. 153 S&F In Repair 40Mm Dia, Cupboard Knobs Fixed With Nut, Screw And Washer Of Mild Steel Bright Finished All As Specified. 154 S&F Ball Catches With 8Mm Dia Steel Ball And Brass Body And Striking Plate Including Letting In And Fixing Complete All As Specified. 155 Supply & Fix In Replacement Of Modular Bell Push Switch 1 Way, 6 Amps, 1 Module Complete All As Specified. 156 Supply & Fix In Replacement Of Call Bell Ding Dong Ac 230 Volt Single Pole Complete All As Specified. 157 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 300 Mm Sweep 900 Rpm Metal Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Hole Making Louver Complete All As Specified And Directed By Engineer-In-Charge. 158 S & F Modern Energy Efficient Bedroom Muziris Wall Decorative Light Of Capacity 20 Watt Single Headed 240 Volt, Ip20 Rating, Controller Type (Push Button), Product Weight 1.04 Kg, Body Material (Metal), Power Source (Corded Electric),Lamp Base E27, Colour(Bronze) Incl Electrically Connection , Including Removing Of Unserviceable Decorative Light Fittings Of Any Description Complete All As Specified And Directed By Engr-In-Charge. Make: Philips Model No 31425 Or As Equivalent. 159 Excavating In Trenches N Exc 1.50M In Width And N Exc 1.50M In Depth For Foundation, Manholes Etc As Well As N Exc 10 Sqm On Plan Area And Getting Out In Soft/Loose Soil All As Specified And Directed. 160 M&L For Pcc 1:5:10 Type E-2, Using 40Mm Graded Crushed Stone Aggregate In Foundation, Filling And Mass Concrete All As Specified And Directed. 161 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 162 S&F Mild Steel Deformed Bars, 6Mm To 8Mm Dia Cut To Length, Bent To Shape Required Including Cranking And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0-.90Mm Dia Complete. 163 M&L For Form Work To Soffits Of Suspended Slabs Such As Roof Slabs Etc For Rough Finished Concrete Surface Complete All As Specified And Directed. 164 M&L For Form Work To Sides For Slabs And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N Exc 20 Cm Wide For Fair Finished Concrete Surface Complete All As Specified And Directed. 165 Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams And Similar Work, Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete. 166 Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions, Square, Rectangular Or Polygonal For Rough Finished Flat Surfaces Of Concrete. 167 M&L For Rendering In Cement Mortar (1:6) 10 Mm Thick Finished Even Smooth Complete All As Specified On Brick Or Concrete Surface Of Fair Faces. 168 M&L 15Mm Thick Cement Plaster In Two Layer First Coat In Cm 1:6,10Cm Thick & Second Layer 5Mm Thick In Cm 1:4 Mixed With Wpc 3% By Weight Of Cement Including Finishing Fair & Even On Brick Or Concrete Surfaces Of Othern Than Fair Faces. 169 M&L For 5Mm Thick Cement Plastering To Rcc Surfaces In Cm :1:3) Finished Even And Smooth W/O Using Extra Cement On Ceiling Surfaces. 170 S&F Stainless Steel Butt Hinges Medium Weight Cold Rolled Isi Marked Of Size 100 Mm Complete All As Specified And Directed. 171 M&L For Ms Framed Guard Bars Conforming To Fe-410-0 Or Fe-310-0 Welded To Steel Windows/Ventilations Complete All As Specified And Directed. 172 S&F Vitrous China Squatting Pan Of Orissa Patterns Long Pan Size 580Mx440Mm White With P Or S Trap Front Of Back Inlet And Foot Rest Including Long Band Any Pattern (Excluding Flushing Cistern And Flush Pipe) Including Provision For Lime Concrete Bedding. 173 S&F Pvc Flushing Cistern Low Level 10 Ltr Cap With Inlet Ball Valve Float And Handle Syphonic Action Type Incl Brackets And Flush Pipe Of Polythene Of Low Or High Density Isi Marked. 174 S & F In Repairs Vitreous China Oval Shape Wash Basin, White, Flat Back, Size 580 X 450 Mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets With 32 Mm Dia Waste Fittings, Brass, Chromium Plated With Waste Pipe Complete All As Specified. 175 S&F Looking Mirror Of Selected Quality Mounted On 6 Mm Thick Ply And Fixed To Wall With Wooden Plugs Chromium Plated Brass Screws And Washers. 176 S&F For Ci Floor Trap With Incl Jointing With Waste Pipe In Cement Mortar Of Size 100Mm. 177 S&F Gully Trap Stone Ware Square Of Round Mounted Type P Of Size 150X150Mm. 178 S&F 20Mm Dia Stop Valve Of Copper Alloy Screwed Down High Pressure With Crutch Or Butter Fly Handle Screwed On Both Ends For Iron Pipe Or For Union Fixed. 179 S&F Pvc Connection 15Mm Dia 600Mm Long Of Heavy Grade Screwed One End To Inlet Of Whb/Pillar Tap/Cistern Etc Complete Incl Brass Union Coupling On Both Ends Connfirming To Is-3076 Complete With Connector For Connection Old Water. 180 S& F For Ci Pipe 75Mm Dia Laid In Floor In Any Length With Or Without Cars With Cement Joint (Waste & Vent Pipe). 181 All As Per Item No 38 Here In Before But 100Mm Dia. 182 S&F For Ci Bend Any Radius Disminshing Pieces Or Tyes Of 100Mm Bore With Ducks For Or Head Rest. 183 S&F For Ci Branch Pieces Single Equal Or Unequal Ordinary Or Inverted Or With Paralled Brnach 100 Mm Bore. 184 S&F Cast Iron Sand Cast Pipe 100 Mm Dia With Or Without Cars With Cement Joint Fixed To Walls. 185 S&F Cast Iron 100 Mm Cowl. 186 M&L For Pcc 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate)75Mm Thick On In Sub Base Of Fllor .. 187 M&L For 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directd. 188 M&L For Coloured Glazed Ceramic Tiles On Vertical Surface (300Mmx600Mx7M) Thick Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 189 M&L For Coloured Non Skid Ceramic(300X300Mm) Tiles 7 To 8Mm Thick As In Floor Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 190 S&F Steel Ventilation With Top Hung Shutter Including Hinges, Steel Peg Stay Complete. 191 S&F 4Mm Thick Sheet Glass Of Figured,Pin Headed And Glazing With Oil Putty In Square N Exc 0.50 Sqm In Each. 192 M&L For Preparation Of Newly Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Over 10 Cm Width Or Girth Complete All As Specified And Directd. 193 M&L For Preparation Of Newly Plastered Surfaces And Applying Two Coats Of Cement Base Paint Over A Coat Of Chalk Whiting Complete All As Specified And Directd. 194 M&L For Three Coats Of White Wash On Wall Of Newly Plastered Surface. 195 S&F For Preparation Of Newly Plastered Surfaces And Applying Three Coats Of White Wash On Ceiling. 196 M & L For Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. 197 S&F Factory Made Solid Pvc Moulded Door Shutter, With Particle Board Core, 28 To 30Mm Thick (Stiles), With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Pvc Sheet On The Front Face & 2Mm Plain Colour Pvc Sheet On Back Face & 5Mm Thick Plain Colour Pvc Sheet On Back Face, Supplying & Fixing In Frame At Site As Per Specification & Drawing All As Specified. 198 S&F Aluminium Tower Bolt 150Mm Long Stove Enamelled Black With Bright Bolt & Fixed. 199 S&F Aluminium Sliding Door Bolt With Hasp And Staples Type Bolt Type , 300Mm Long Stove Enamelled And Fixing Clips Of Sheet Cast Or Extruded Section Or Cast Aluminium Alloy And Fixed All As Specified. 200 S&F Aluminium Alloy Handle Of 100M Size Oval Type Stove Enamelled & Fixed All As Specified. 201 M&L For Rendering 10Mm Thick Cm (1:4) On Roof Slab Top, Mixed With Water Proofing Liquid Finished Even And Fair Without Using Extra Cement Complete All As Specified. Note: Water Proofing Liquid Shall Be Measured And Paid Separately. 202 M & L For Cleaning The Newly Plastered Surfaces Of Concrete ( Roof Etc) With Wire Brushes And Applying Water Proofing Treatment As Under :-I) Apply One Coat Of Oil Bound Bituminous Primer @ 0.25 Kg/Sq.M Ii) Providing And Laying 3 Mm Thick App Modified Water Proofing Membrane Weighing Not Less Than 3.5 Kg / Sqm Reinforced With Non Woven Polyester Mat Weighing Not Less Than 160 Gm/Sqm All As Specified Procured From Any One Of The Approved ManufacturerS Iii) Apply One Coat Of Solar Reflective Bituminous Aluminium Paint @ 0.15 Kg/Sqm Over Membrane Over Non Assesble Roof Surfaces Complete All As Per ManufacturerS Instructions And As Directed . 203 M/L Brick Work In Cm1:4, In Half Brick Thick Wall. 204 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 205 S/F Vitreous China Toilet Paper Holder Fixed To Walls With Chromium Plated Cp) Brass Screws 206 S/F Vitreous China Soap Dish Of Appx Size 160*160*90Mm Any Type Fixed To Plugs With Chromium Plated Brass Screws 207 S/F Sheet Glass Shelf Assembly Consistig Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Brackets Guard And Railing 60Cm Long 208 S & F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges Complete All As Specified. 209 M & L For Granite 20 Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Griding And Polishing Types All As Specified. 210 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 211 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 212 S&F Health Faucet Including Ms/Anodised Hanging Device Fixed Complete All As Specified And As Directed. 213 Surface Excavation Not Exceeding 30Cm Deep And Averaging 15Cm Deep And Getting Out In Loose / Soft Soil All As Specified And Directed. 214 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 215 M & L 100Mm Thick Pcc 1: 4: 8 Type D2 (Using 40Mm Graded Stone Aggregate) As In Sub Base Complete All As Specified And Directed. 216 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Rubber Moulded Any Shape And Size Confirming To Is 15658-2006 Of 60Mm Thickness, M-35 Grade With Grey And Pigment As In Floor/Pavement Complete All As Specified And As Directed. 217 M&L For Providing Precast Concrete Type C-1, 1:2:4(Using 20Mm Graded Stone Aggregate) As In Kerb Blocks With Plain Fiar Faces, Including Chamferes, Weathering, Throating Etc And Setting In Mortar 1:4 Complete With Joints To Match. 218 M&L For Cement Concrete Type 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 219 M & L For Sand Filling Under Floors Or In Foundation Including Watering And Consolidation 220 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X25 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 221 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 222 M&L For Boring Of Holes Under Road, Pavement, Hard Standing By Trench-Less Technology Using Ultrasound Technique And Necessary Machine Suitable To Pass Through 40 To 80 Mm Bore Gi Tubing And Cable Etc Complete All As Specified And Directed.Note: Gi Pipe Shall Be Measured And Paid Seperately Under Relevant Item.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
5.
Housing Urban and Rular Development #11475953 Technical Bid
bill of quantities (boq) for renovation of toilets at eight floors (ground floor, 1st, 2nd, 3rd, 4th, 5th, 6th & 7th floors) and pantry at 8th floor of ncdc headquarters building, 4, siri institutional area, august kranti marg, new delhi – 110016 schedule a- civil works sl. no. description of items unit quantity rate amount sub-head : 1 dismantling / demolition works , dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , dismantling tile work in floors,walls and roofs laid in cement mortar including stacking material within 50 metres lead. , dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead , of area 3 sqm. and below , dismantling old plaster or water proofing or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar , dismantling of flushing cistern of all types c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. , vitreous china water closet indian / european , vitreous china wash basins / urinals , dismantling existing floors of bathrooms and toilets as per instructions. the cost inclusive of stacking of dismantled materials (serviceable material) in good condition and also disposal of broken unserviceable materials at contractors own place. , dismantling of existing cp brass fittings, bottle traps and existing gi & ci pipes / fittings, wherever required in toilet as per instructions. the cost inclusive of stacking of existing brass fittings as per instructions of engineer - in - charge and the location directed by him. , dismantling & removal of malbaa from the sunken areas including stacking of serviceable and unserviceable material separately in the lead of 50 mts.after digging the same till the existing waterproofing is visible. the unserviceable material (inclusive of existing waterproofing, if any, of any nature) shall be removed from the sunken areas and the contractor should stack the same at his own place. sub total 0.0 sub head:2 wood work , providing and fixing wood work in frames of doors, windows, celestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). a. sal wood , providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including isi marked stainless steel butt hinges with necessary screws , extra for providing and fixing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter is to be measured for payment purpose). sub total 0.0 sub head:3 finishing work , providing and applying 12mm cement plaster including making grooves wherever required of mix 1:6 . (1 cement :6 coarse sand) , brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand) , providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer-in-charge. , 12.5 mm thick square edge pvc laminated gypsum tile of size 595x595 mm, made of gypsum plasterboard, manufactured from natural gypsum as per is 2095 part i and laminated with white 0.16mm thick fire retardant pvc film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side pvc film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. , providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. size of tile 800x800 (note: a. base rate of tile in the range of rs.90-95/- per sq.ft. b. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 800x800 mm (note: a. base rate of tile in the range of rs.90 -95 per sq.ft. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. completeat all levels.granite stone slab of colour black, cherry/ruby red , providing and fixing1500x500 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed towooden cleats with c.p. brass screws and washers complete.mirror make:asahi, saint gobain or equivalent as approved by engineer in charge sub total sub head:4 waterproofing work , providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: (i) ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv)ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). , providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. , supplying and filling in sunken with sand under floors, including watering,ramming, consolidating and dressing complete. sub total 0.0 sub-head : 5 plumbing / sanitary work , providing and fixing white vitreous china pedestal type water closet(european type-one piece) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flushbend, overflow arrangement with specials of standard make and mosquitoproof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floorswherever required : w.c. pan with isi marked white solid plastic seat and lid , providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required:white vitreous china orissa pattern w.c. pan of size 580x440mm with integral type foot rests , providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (i)white vitreous china wash basin size 630x450 mm with a pair of 15 mm c.p. brass pillar taps , providing and fixing white vitreous china flat back half stall urinal of 710x485x300 mm or 640x370x310 or 610x390x370mm sizes with white pvc automatic flushing cistern, with fittings,standard size c.p. brass flush pipe, spreaders with unions and clamps (allin c.p. brass) with waste fitting as per is : 2556, c.i. trap with outlet gratingand other couplings in c.p. brass, including painting of fittings and cuttingand making good the walls and floors wherever required : range of two half stall urinals with 10 litre p.v.c. automatic flushing cistern , providing and fixing stainless steel a isi 304 (18/8) kitchen sink as peris:13983 with c.i. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the walls wherever required :kitchen sink with drain board 510x1040 mm bowl depth 225 mm , providing and fixing stone slab with table rubbed, edges rounded and polished,of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting achase of appropriate width with chase cutter and embedding the stone in thechase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 6 mm nominal size) as per direction of engineer-in-charge and finished smooth. (granite stone of approved shade) , providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or quivalent make) , 15mm nominal outer dia. pipes , 20mm nominal outer dia. pipes , 32mm nominal outer dia. pipes , 50mm nominal outer dia. pipes , providing and fixing 3 layer pp-r (poly propylene random copolymer)pipes confirming to is:15801 uv stabilized & anti - microbial fusion welded,having thermal stability for hot & cold water supply, including all pp - r plain & brass threaded polypropylene random fittings, including trenching,refilling & testing of joints complete as per direction of engineer-in-charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or equivalent make) , 100mm nominal outer dia. pipes , 150mm nominal outer dia. pipes , all internal sanitary works , providing and fixing c.p. brass long nose bib cock of approved quality (15 mm nominal bore) , providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 , providing and fixing brass 2 in 1 pillar cock of approved quality (15 mm nominal bore) sub total 0.0 total sch a 0.0 schedule b- elctrical works sl.no. description unit quantity rate amount (in rs.) , wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable etc. as required.(wire make- havells, polycab, finolex or equivalent. modular switch, socket, box, plate, etc make- havells, roma or equivalent. steel conduit make-bec, unicon or equivalent) , group c , wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/recessed steel conduit as required.(wire make- havells, polycab, finolex or equivalent) , 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire , supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.(make- havells, schneider or equivalent) , 250 mm x 300 mm x 100 mm deep , 180 mm x 100 mm x 60 mm deep , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(make- havells, roma or equivalent , 3 pin 5/6 a socket outlet , 5/6 a switch , 15/16 a switch , 6 pin 15/16 a socket outlet , supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc. as required.(make- havells, finolex or equivalent , 8 module (125mmx125mm) , 12 module (200mmx150mm) , 6 module (200mmx75mm) , installation, testing and commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(make- havells, crompton or equivalent , 510 mm sweep , led down lighter (cob type) (system lumen efficacy ≥120 lm/watt ) supplying, installation, testing & commissioning of led recessed/surface down lighter (round / square/ rectangular) cob type of following body material and construction as per is : 10322 with driver as per the requirement with driver efficiency 85%, operating voltage ac 140-270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10%, p. f.≥0.95, ip20, cri 80 , ugr (unified glare rating) 19, flicker free (flicker should be below 5 %), life time (led, driver & electrical circuitry), life time of minimum 50000 burning hours with, 70% of initial lumen maintained till life ends , cct 3000°k / 4000°k / 5700°k /6500°k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted shape size and cct shall be as approved by engineer-in- charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). powder coated die cast /extruded aluminium body including trim with aluminium reflector(make- havells, philips or equivalent) , 12 -15 watt , led batten light (system lumen efficacy ≥120 135 lm/watt) supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency 85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f.≥0.95, ip20, cri 80, flicker free (flicker should be below 5 %), life time (led,driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000°k / 4000°k / 5700°k /6500°k 46 delhi schedule of rates (e&m)-2025(as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output. lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c).powder coated die cast /extruded aluminium body (thickness 1.20 mm)(make- havells, philips or equivalent) , 18- 22 watt , led strip light (make- philips, wipro or equivalent) , automatic hand dryer (make- dolphy, euronics or equivalent) , automatic touchless toilet urinal sensor alongwith solenoid valve, flexible hose, etc(make- parryware, jaquar or equivalent) total sch b total total (sch a+schb) 0.0 say rs.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 5
6.
New and Renewable Energy #11454900 AOC
Bids Are invited for Title1 - Wall painting with acrylic emulsion paint , Title2 - Providing and applying white cement based , Title3 - Finishing walls with Acrylic Smooth exterior paint , Title4 - 15 mm cement plaster , Title5 - Neat cement punning , Title6 - Providing and fixing bright finished brass hanging type floor door stopper , Title7 - Painting with synthetic enamel , Title8 - Applying one coat of water thinnable cement primer , Title9 - 6mm cement plaster , Title10 - Providing and fixing Ist quality ceramic glazed wall tiles , Title11 - White washing with lime , Title12 - Clearing and stripping the site , Title13 - Supply and transport of earth , Title14 - Earth work in excavation , Title15 - Providing and laying in position specified grade of PCC , Title16 - Providing and laying in position specified grade of reinforced cement concrete , Title17 - Steel reinforcement , Title18 - Centering and shuttering , Title19 - Structural steel work riveted , Title20 - Providing and fixing ISI marked flush door shutters , Title21 - Providing and fixing concertina coil fencing , Title22 - With GI barbed wire , Title23 - Providing and fixing GI chain link fabric , Title24 - Removal of wet dry sludge , Title25 - Removal of existing damaged glass , Title26 - Welding by gas or electric plant , Title27 - Removal of existing damaged door , Title28 - Dismantling colour coated roofing Sheets , Title29 - Rectifying all defects causing leakage in pre coated iron profile roofing sheets , Title30 - Providing and fixing precoated galvanised iron profile sheets , Title31 - Demolishing RCC work by mechanical means , Title32 - Supplying and applying bituminous solution primer , Title33 - Random rubble masonry , Title34 - Brick work with common Fly ash bricks , Title35 - Providing and injecting chemical emulsion , Title36 - Half brick masonry , Title37 - Providing and fixing white vitreous china pedestal type water closet , Title38 - Providing and fixing wash basin , Title39 - Providing and fixing beveled edge mirror , Title40 - Providing and fixing CP brass bib cock , Title41 - Providing and fixing CP brass stop cock , Title42 - Providing and fixing water closet squatting pan , Title43 - Providing and laying Ceramic glazed floor tiles , Title44 - Providing and fixing on wall face un plasticised Rigid PVC SWR pipes , Title45 - Providing and placing on terrace polyethylene water storage tank , Title46 - Providing and fixing inposition collapsible steel shutters , Title47 - Providing and fixing PTMT pillar cock , Title48 - Providing and laying Bituminous concrete , Title49 - Sub-base course , Title50 - Base course , Title51 - Providing and fixing brass 100mm mortise latch an dlock with 6 levers , Title52 - Developing lawn , Title53 - 30 mm thick factory made Polyvinyl Chloride , Title54 - Providing and fixing GI chain link fabric , Title55 - Do GI Pipe 25m dia , Title56 - 32 mm dia nominal bore , Title57 - 50 mm dia nominal bore , Title58 - Providing and fixing false ceiling , Title59 - Supplying and filling in plinth , Title60 - Providing and laying dampproof course , Title61 - Finishing with Epoxy paint , Title62 - Providing fixing glass panes , Title63 - Providing and laying vitrified floor tiles , Title64 - Providing and laying Polished Granite stone , Title65 - Providing and fixing Stainless Steel , Title66 - Providing and fixing Stainless Steel 24 inch Towel Rod , Title67 - Providing and fixing of Overhead Shower , Title68 - Providing and fixing of Shower Arm Casted Chrome , Title69 - Providing and fixing with all fittings of Angle Cock , Title70 - Providing and fixing with all fitting of two way bib Cock , Title71 - Providing and fixing with all fitting of Float valve , Title72 - Constructing masonry Chamber , Title73 - Dry stone pitching , Title74 - Providing and fixing gun metal gate valve , Title75 - Providing and laying 60mm thick faciory made cement concrete interlocking paver block Total Quantity : 14934
Contract Date: Ref. Documents Contract Value : 34.73 Lakh
Boards / Undertakings / PSU No of Bidders 2
Andhra Pradesh View Result →
9.
Housing Urban and Rular Development #11432190 Price Bid
Tender for 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq M On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. - All Kinds Of Soil , 2.25Filling Available Excavated Earth (Excluding Hard Rock/Ordinary Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. , 2.27Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , 4.1.4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1 :2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mmnominal Size) , 4.17Making Plinth Protection 50 Mm Thick Of Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand (Zone-Ill) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level [ 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) ] , 5.33.1.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.33.2.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.22.6Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.9.1Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases For Columns , 5.9.5Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.21Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , 6.1.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 7.1.1Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1 :6:12 (1 Cement: 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 8.14.4.1Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1 :2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :White Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 70 Mm Thick , 8.25.1Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 40 Mm Thick , 8.25.4Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 12 Mm Thick , 10.16.1Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , 10.25.1Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , 11.41.2Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , 12.34Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg I M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm)@ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , 12.50Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , 12.51.2 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Flashings/ Aprons.( Upto 600 Mm) , 12.51.6 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Gutter (600 Mm Over All Girth) , 13.50.2Applying Priming Coat: With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood , 13.50.3Applying Priming Coat: With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , 13.62.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , 13.68.1French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , 16.69 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer In-Charge (Length Of Finished Kerb Edging Shall Be Measured To Calculate Volume For Payment). (Precast cement concrete Kerb Stone Shall Be Approved By Engineer-In-Charge). , 16.92Providing And Fixing 10X10x7.50 Cm Granite Stone Block Hand Cut And Chisel Dressed On Top, For Paving In Floors, Drains Etc. Laid Over 20 Mm Thick Base Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints 10 Mm Wide Filled With Same Mortar Including Ruled Pointing Etc. Complete As Per Direction Of Engineer-In-Charge. , 1-2Excavationinfoundationfor Retaining,Breastwallsetc, Inall Typesofsoils And Rocks Includingall Lead, Lift Anddisposal Of Surplusmaterial Asper Direction Of Engineer- In- Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , 1-4 Randomrubblestonemasonry Laid In1:6Cement Andsandmortar, In Breastwalls,Retainingwalls,Parapets,Scuppers,Etc. Includingsupplyofall Material, Labour, T&Pand Royaltiies Etc. Complete As Per Drawingand Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , 1-3 Randomrubblestonemasonry Laiddry, Inbreastwalls, Retainingwalls, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Completeasper Drawingand Technical Specificationsclauses702, 704, 1202 & 1203 Of Mord Specifiction , 1-5 Handpackedstonefillinginbackofwallls Includingcostofallmaterials, Royality,T&Petc.Completeasperdirectionofengineer-In-Charge. (Asper Pwd Uttarakhand Specifications) , 2-2Concretewithcement, Coarsesandand40mmgaugestoneballast In Proportion1:4:8 In Foundationsand Floors Includingsupplyof Allmaterial, Labour Andt&Petc. Required For Proper Completionof Thework. Asper Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , 3-7Removal Of Unsuitable Soil With Disposal Upto 1000 M Removal Of Unsuitable Soil Including Excavation, Loading And Disposal Upto 1000 M Lead But Excluding Compaction Ground Supporting Embankment Subgradereplacement By Suitable Soil, Which Shall Be Paid Separately As Per Clause 303.5.2As Per Technical Specification Clause 302.3.11 , 12-9Providing Weepholes In Brick Masonry/Stone Masonry, Plain/Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Providing & Supplying Of 25W Self Ballasted Led , Providing & Supplying Of Decorative Lighting Pole Of 4M , Providing & Fixing Of Aayush Wellness Based Signages/Boards Including Vertical Pole & Ms Sheet , Providing & Fixing Of Aayush Wellness Based 3D Paintings With Pop Texture Including Texture Paint
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
10.
Housing Urban and Rular Development #11432187 Price Bid
Tender for Demolishing Of Cement Concrete Manually & Disposal Of Material Within 50 Metres.Nominal Concrete 1:3:6 Or Richer Mix , Demolishing Of Reinforced Cement Concrete Work Manually Including Stacking Of Steel Bars & Disposal Of Material Within 50 Metres. , Demolishing Of Brick Work Manually. In Cement Mortar Disposal Of Material Within 50 Metres , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Of Doors & Windows Frames & Chawkhats Of Area Blow 3 Sqm. , Dismantiling Of Roofing Including Ridges, Hips Valley And Gutters Etc. And Stacking Gs Sheet , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As 10 Sqm On Plan Including Getting Out And Disposal Of Excavated Earth Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In- Charge: , Earth Work In Excavation By Mechanical Means By Hydraulicexcavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or10 Sqm On Plan Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth,Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 , Providing And Laying Cement Concrete In Kerbs, Steps And The Like At Or Near Ground Level Excluding The Cost Of Centering, Shuttering And Finishing. 1:1.5:3 (1 Cement: 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete. , Reinforced Cement Concrete Work In Walls, Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement. 1:1.5:3 (1 Cement :1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Walls Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level- Thermo-Mechanically Treated Bars , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level Cement Mortar 1 :4 (1 Cement :4 Coarse Sand) , Three Track Three Panels Sliding Window With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. Using R3 Series With Frame (98 Mm & Above) X (40 Mm & Above) & Sash (30 Mm & Above) X (55 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Handle On Two End Panels Along With Multi-Point Locking System (Height Upto 1.8 Metre) , Casement Door Double Panel With French (False) Mullion With Zinc Alloy (Zamak) 30 Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides.Using R4 Series With Frame (64 Mm & Above) X (55 Mm & Above) & Sash (64 Mm & Above) X (100 Mm & Above) & French (False) Mullion (64 Mm & Above) X (60 Mm & Above). (Height Above 2.5 Metre). , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Providing And Laying 60 Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M-30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , 12 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Coarse Sand) , 20 Mm Cement Plaster Of Mix 1:6 (1 Cement: 6 Coarse Sand) , Providing & Applying White Cement Based Putty Of 2 Mm Thick Of Approved Brand Over Plastered Wall Surface For Even & Smooth Wall Fiinsh , Colour Washing Such As Green, Blue Or Buff To Give An Even Shade. New Work (Two Or More Coats) With A Base Coat Of Whiting. , Distempering With 1St Quality Acrylic Distemper Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour. New Work Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre , Finishing Walls With Water Proofing Cement Paint Of Required Shade Two Or More Coats Applied. , Finishing With Delux Multi Surface Paint For Interiors Using Primer As Specified Two Or More Coats Applied On Wall At 1.25Ltr/10 Sqm Over And Including And On Coat Of Special Primer , Applying Primer Coat With Ready Mix Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacturer On Steel Works And Gi , Finishing With Epoxy Paint Two Coats On All Location Prepared And Applied On Steel , Providing And Fixing Dry Cladding Upto 10 Metre Height With 30 Mm Thick Gang Saw Cut Stone With Machine Cut Edges Of Uniform Colour And Size Upto 1Mx1m, Fixed To Structural Steel Frame Work And/ Or With The Help Of Cramps, Pins Etc. And Sealing The Joints With Approved Weather Sealant As Per Architectural Drawing And Direction Of Engineer-In-Charge , Providing And Fixing Insulating Board Ceiling Of Approved Quality With Necessary Nails Etc. Complete. Flame Retardant Face Insulating Board, 12 Mm Thick , Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183. Density 16 Kg/M³, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Placed Over Existing False Ceiling And Held In Position By Criss-Crossing Gi Wire , Providing Wood Work In Frames Of False Ceiling, Partitions Etc. Sawn And Fixed In Position With Necessary Stainless Steel Screws Etc. , Providing And Fixing 35 Mm Thick Factory Made Laminated Veneer Lumber Door Shutter Conforming To Is : 14616 And Tads 15:2001 (Part B), Fixing With Butt Hinges Of Required Size With Necessary Screws, All Complete As Per Directions Of Engineer- In-Charge And Panelling With Panels Of 12 Mm Thick Plain Grade -1, Medium Density Flat Pressed Three Layer Particle Board , Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows. Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. Particle Board 12 Mm Thick. , Varnishing With Varnish Of Approved Brand And Manufacture : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture. Two Or More Coats Of Glue Sizing With Copal Varnish Over An Under Coat Of Flatting Varnish , French Spirit Polishing Two Or More Coats On New Works Including A Coat Of Wood Filler , Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture :
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
11.
Housing Urban and Rular Development #11432178 Price Bid
Tender for Excavation In Foundation For Retaining, Breast Walls Etc, In All Types Of Soils And Rocks Including All Lead, Lift And Disposal Of Surplus Material As Per Direction Of Engineer - In - Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , Removal Of Unsuitable Soil With Disposal Upto 1000 M Removal Of Unsuitable Soil Including Excavation, Loading And Disposal Upto 1000 M Lead But Excluding Compaction Ground Supporting Embankment Subgrade Replacement By Suitable Soil, Which Shall Be Paid Separately As Per Clause 303.5.2 As Per Technical Specification Clause 302.3.11 , Concrete With Cement, Coarse Sand And 40 Mm Gauge Stone Ballast In Proportion 1:4:8 In Foundations And Floors Including Supply Of All Material, Labour And T&P Etc. Required Forproper Completion Of The Work. As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , Random Rubble Stone Masonry Laid In 1:6 Cement And Sand Mortar, In Breast Walls, Retaining Walls, Parapets, Scuppers, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , Random Rubble Stone Masonry Laid Dry, In Breast Walls, Retaining Walls, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , Hand Packed Stone Filling In Back Of Wallls Including Cost Of All Materials, Royality, T&P Etc. Complete As Per Direction Of Engineer-In- Charge. (As Per Pwd Uttarakhand Specifications) , Providing Weepholes In Brick Masonry/Stone Masonry, Lain / Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Excavation In Hilly Areas In Ordinary Rock By Mechanical Means Not Requiring Blasting (With Out Dozer) Excavation In Hilly Area In Ordinary Rock Not Requiring Blasting By Mechanical Means Without Using Dozer Including Cutting And Trimming Of Slopes And Disposal Of Cut Material With A Lift Upto 1.5 M And Lead Upto 20 M As Per Clause 1603.2. , Providing And Laying Of Stone Set Pavement Over 2.5 Cm Thick Bedding Layer Of Plain Cement Concrete 1:2:4 Which Shall Further Be Placed Over 10 Cm Thick Dry Stone Kharanja Or Crushed Stones Base Over A Prepared Subgrade As Per Drawings And Technical Specifications. The Size Of Stones Shall Not Be Less Than 20Cm X 20Cm And Thickness Of Stones Shall Vary From 10Cm To 15 Cm. The Work Includes Filling Of Joints With Plain Cement Concrete 1:2:4 As Per The Standard Drawings And Instructions Of The Engineer-In-Charge. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 6.4.1 Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 (1 Cement: 6 Fine Sand) - Outer Plaster , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : 13.41.1 New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Seamless Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggreentrance Gate 20 Mm Nominal Size Derived From Natural Sources) , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggreentrance Gate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggreentrance Gate 20 Mm Nominal Size Derived From Natural Sources) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , Random Rubble Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like. Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Pointing On Stone Work With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) : Raised And Cut Pointing , Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 12 Mm Thick , French Spirit Polishing : Two Or More Coats On New Works Including A Coat Of Wood Filler , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg / M3, 50Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Flashings/ Aprons.( Upto 600 Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Gutter (600 Mm Over All Girth) , Manufacturing, Supplying And Fixing Retro Reflective Sign Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity Encapsulated Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iv Of Astm-D 4956-01 In Blue And Silver White Or Other Colour Combination Including Subject Matter, Message (Bi-Lingual), Symbols And Borders Etc. As Per Irc ; 67:2001, Pasted On Substrate By An Adhesive Backing Which Shall Be Activated By Applying Heat And Pressure Conforming To Class -2 Of Astm-D-4956-01 And Fixing The Same With Suitable Sized Aluminium Alloy Rivets @ 20 Cm C/C To Back Support Frame Of M.S. Angle Iron Of Size 25X25x3 Mm Along With Theft Resistant Measures, Mounted And Fixed With 2 Nos. M.S. Angles Of Size 35X35x5 Mm To A Vertical Post Made Up To M.S. Tee Section Ismt 50X50x6 Mm Welded With Base Plate Of Size 100X100x5 Mm At The Bottom End And Including Making Holes In Pipes, Angles Flats, Providing & Fixing M.S. Message Plate Of Required Size, Steel Work To Be Painted With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade And Of Approved Brand & Manufacture Over Priming Coat Of Zinc Chromate Yellow Primer (Vertical Ms-Tee Support To Be Painted In Black And White Colours).Backside Of Aluminium Sheet To Be Painted With Two Or More Coats Of Epoxy Paint Over And Including Appropriate Priming Coat Including All Leads And Lifts Etc. Complete As Per Drawing, Specification And Direction Of Engineer-In-Charge. 16.59.1 Mandatory/ Regulatory Sign Boards Of 900 Mm Diametre With Support Length Of 3750 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone - Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth , Providing And Fixing Plain Lining With Necessary Screws/Nuts & Bolts/ Nails, Including A Coat Of Approved Primer On One Face, And Fixed On Wooden /Steel Frame Work, Complete As Per Direction Of Engineer-In- Charge (Frame Work Shall Be Paid For Separately). 12 Mm Thick Commercial Ply Conforming To Is : 1328 Bwr Type , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg / M3, 50Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Of External Wall System On Light Gauge Steel Frame Work With Outer Face Cement Boards As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60 Cm C/C Of Approved Make. A Groove Of 2 Mm To 3 Mm Shall Be Maintained And Grooves Shall Be Sealed With Silicon Based Sealant. The Board Shall Be Fixed In A Staggered Pattern. Screws Shall Be Of Counter Sunk Rib Head Of 1.60 Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm And. Internal Face 12.5 Mm Thick Gypsum Plaster Board Fixed On Cement Board As Per Standard Sizes Fixed With Self- Drilling / Taping Screws / Fasteners @ 60Cm C/C Of Approved Make, Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish.(Cost Of Frame Work To Be Paid For Separately) Outer Face- Outer Face Having 6 Mm Thick Fiber Cement Board Type A, Category-Iv As Per Is:14862:2000 Fixed On 9 Mm Thick Fiber Cement Board, Type A, Category-Iv As Per Is:14862:2000 (High Pressure Steam Cured) Inner Face- 12.5 Mm Thick Gypsum Plaster Board Conforming To Is 2095:2011 Fixed On 8 Mm Thick Fibre Cement Board Of Type B, Category-Iii As Per Is:14862:2000 (High Pressure Steam Cured) , Providing And Fixing Internal Wall Panels On Light Gauge Steel Frame Work With 12.5 Mm Thick Gypsum Plaster Board Conforming Is 2095:2011 Fixed On Cement Board As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60 Cm C/C Of Approved Make, Screws Shall Be Of Counter Sunk Rib Head Of 1.60 Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm. Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish.(Cost Of Frame Work To Be Paid For Separately Cement Fiber Board 8 Mm Thick Of Type B, Category Iii As Per Is 14862:2000 (High Pressure Steam Cured) , Providing And Fixing In All Exterior Face Panels Breathable Vapour Barrier Underneath The Cement Fiber Board As Per National Building Code 2009 Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular/ L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 10.15.1 Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size , Providing And Fixing Pressed Steel Door Frames Conforming To Is: 4351, Manufactured From Commercial Mild Steel Sheet Of 1.60 Mm Thickness, Including Hinges, Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25 Mm, Or Base Ties Of 1.60 Mm, Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Including M.S. Pressed Butt Hinges 2.5 Mm Thick With Mortar Guards, Lock Strikeplate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface As Directed By Engineer In-Charge: Profile B Fixing With Carbon Steel Galvanised Dash Fastener Of Required Dia And Size (To Be Paid For Separately) , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding , Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With 12 Mm Mild Steel U Beading (Mosquito Jali). , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 10.30.1 4.0 Mm Thick Glass Panes , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 125 Mm , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 250X10 Mm , Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 300X16 Mm , Providing And Fixing Isi Marked 85X42 Mm Oxidised M.S. Pull Bolt Lock Conforming To Is : 7534 With Necessary Screws Bolts, Nut And Washers Etc. Complete (Copper Oxidised As Per Is 1378). , Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc. Complete. Single Rubber Stopper , Providing And Fixing Ptmt Door Catcher Of Length 72 Mm And Dia. Of 42 Mm With Suitable Washers Weighing Not Less Than 33 Gms , Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Supplying And Filling Of Earth By Mechanical Transport Including Loading, Unloading & Stacking Beyond 5Km Upto 10Km & Beyond 10Km Upto 20Km (Including All) , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level. Concrete Of M30 Grade With Minimum Cement Content Of 350 Kg /Cum , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry , 12 Mm Cement Plaster Of Mix: 1:6 (1 Cement: 6 Fine Sand) - Inner Plaster , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screw , Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side /Top /Centre Hung, With Beading And All Members Such As F7d,F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Riming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment). 10.11.1 Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sq.M Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sq M Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sq M) , Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : (A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. (B) Second Layer Of Slurry Of Cement @ 0.242 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
12.
Housing Urban and Rular Development #11432177 Price Bid
Tender for Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 6.4.1 Cement Mortar 1 :4 (1 Cement: 4 Coarse Sand) , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) 13.1.2 , Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour. Two Coats 13.83.2 , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1 :4 (1 Cement: 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm 11.41.2 , Polishing In High Gloss/Matt Finish Melamine Clear Polish On Wood Work In Required Color/Wooden Shade Texture With Following Process In The Sequence As Detailed 13.116 , Providing And Fixing Flat Pressed Three Layer Particle Or Graded Plain Wood Board Medium Density Exterior Grade (Grade I) Fpt-1, Conforming And Marked To Frame, Backing Or Studding With Screws Etc. Complete (Frames, Backing Or Studding To Be Paid Separately): 9.17.1 12Mmthick , Multipurpose Cement Board Reinforced With Suitable Fibre Cement Screw. 8 Mm Thick Cement Fibre Board, Type- B, Category- Ill As Per Is: 14862 : 2000 9.133.2.1 , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 10.25.2 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 12.50 , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement -All Work Up To Plinth Level :1 :1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Ill) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 5.1.2 , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) I Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 2.8.1 All Kinds Of Soil. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-5000 Or More. 5.22.6 , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall 18.7.1 15 Mm Nominal Dia Pipes , 1 :4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 4.1.8 , Two Track Two Panels Sliding Window With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. 9.147.A1 .1 Using R2 Series With Frame (40 Mm & Above) X (40 Mm & Above) & Sash (25 Mm & Above) X (50 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Touch Locks With Hook (Height Upto 1.2 Metre). , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.51.1 Ridges Plain (500 - 600Mm) , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg I M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm)@ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of: , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , providing and Fixing Of Canada Pine Including Supplying And Fixing Of All Material T&P , Labor Etc , Supply And Fixing Of Wash Basin With Vanity Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Off Towel Ring Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Toilet Paper Holde Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Hand Fauscets Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Angle Valve Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Short Body Bib Cock Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Shop Disc Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Looking Mirror Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Shower Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Wash Basin Mix Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Wall Mix Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Bunk Bed Inluding Of All Material Labour T & P Etc Complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
13.
Housing Urban and Rular Development #11432176 Price Bid
Tender for Supply/Fixing Of Canada Pine Including Supply And Fixing T&P Etc , Providing And Fixing Flat Pressed Three Layer Particle Or Graded Plain Wood Board Medium Density Exterior Grade (Grade I) Fpt-1, Conforming And Marked To Frame, Backing Or Studding With Screws Etc. Complete (Frames, Backing Or Studding To Be Paid Separately):12Mmthick 9.17.1 , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood 9.1.2 , Melamine Polishing On Wood Work (One Or More Coat) 13.114 , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : 13.46.1 New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Providing And Laying Vitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1 :4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily. 11.41.4 , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Lime Mortar 15.7.3 , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm15.23.2 , Dismantling Tiled Roofing With Battens, Boarding Etc. Complete Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead 15.31 , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 10.25.2 , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 6.4.1 Cement Mortar 1 :4 (1 Cement: 4 Coarse Sand) , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) 13.1.2 , Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge (Door Handle, Lock And Stopper Etc.To Be Paid Separately).21.18 , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings And Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 32 Mm Nominal Dia Pipes 18.8.4 , Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick Second Class Teak Wood 9.7.1 , Providing And Fixing 35 Mm Thick Factory Made Laminated Veneer Lumber Door Shutter Conforming To Is: 14616 And Tads 15:2001 (Part B), Fixing With Butt Hinges Of Required Size With Necessary Screws, All Complete As Per Directions Of Engineer- In-Charge And Panelling With Panels Of : (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately)12 Mm Thick Pre-Laminated Particle Board (Decorative Lamination On Both Sides) Grade -1, Medium Density Flat Pressed, Three Layer Particle Board Fpt- I Or Graded Wood Particle Board Fpt- I, Conforming To Is : 3087, Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Pre-Laminated Conforming To Is : 12823, Grade 1, Type - 11 Marked. 9.6.2 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 12.50 , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Kiln Wood9.1.2 , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 12.51.1 , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : 17.2.1 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , Supply And Fixing Of Wash Basin With Vanity Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Off Towel Ring Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Toilet Paper Holde Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Hand Fauscets Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Angle Valve Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Short Body Bib Cock Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Shop Disc Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Looking Mirror Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Shower Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Towel Rack Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Wash Basin Mix Inluding Of All Material Labour T & P Etc Complete. , Supply And Fixing Of Wall Mix Inluding Of All Material Labour T & P Etc Complete. , Supply/Fixing Of Pvc Lours Wall Panelling 6*5*5 Incuding Material Labour T&P Etc , Supply And Fixing Wooden Flooring Quotation Including Material Labour T&P Etc , Supply And Fixing Of Double Bed Rate Including Supplying And Fixing Of All Material T&P Etc Passed Trh Sukhatal , Supply And Fixing Of Dbed Head Rest 6*8Ft Including Supplying And Fixing Of All Material T&P Etc , Supply And Fixing Of Lcd Panel Including Supplying And Fixing Of All Material T&P Etc , Supply And Fixing Of Dressing Mirror Including Supplying And Fixing Of All Material T&P Etc , Supply And Fixing Of Luggage Rack Including Supplying And Fixing Of All Material T&P Etc , Supply And Fixing Of Room Chairs 2+1 Table Including Supplying And Fixing Of All Material T&P Etc , Supply And Fixing Of Ward Robe Table Including Supplying And Fixing Of All Material T&P Etc , Supply And Fixing Of Bed Side Table Including Supplying And Fixing Of All Material T&P Etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
14.
Educational and Research Institute #11428129 Technical Bid
Tender for Purchase Of Sim Reader Trainer Kit In Electronics And Communication Department , Purchase Of Sim Reader Trainer Kit In Ece Department , Sim Reader Trainer Kit Power Supply: • Operates On 230 V Ac ±10%, 50 Hz Mains Supply.• Built-In Regulated Smps Power Supply. • Operating Dc Supply: 5 V / 12 V With Overload And Short-Circuit Protection. Sim Card Interface: • Supports Gsm Sim Cards Compatible With 2G / 3G / 4G / 5G Networks. • Sim Card Read/Write Interface.• Supports Sim Card Initialization, Authentication, And Communication Functions. • Compatible With Standard 6-Pin / 8-Pin Sim Card Sockets. Communication Interface: • Usb 2.0 Interface For Pc Communication. • Rs-232 Serial Communication Interface. • Uart Communication Facility For Embedded System Interfacing. Sim Operating Parameters: • Selectable Sim Clock Frequencies:• 3.579 Mhz • 7.159 Mhz • 14.318 Mhz • Sim Supply Voltage Selection Facility. • Sim Reset And Activation Control. Supported Protocols And Standards: • Gsm Etsi 07.07 And Etsi 07.05 At Command Support.• Iso/Iec 7816 Smart Card Communication Support.• Sim Communication Command Monitoring Facility. Hardware Features: • On-Board Sim Card Socket.• Led Indication For:• Power Status • Sim Detection • Reset Activity • Data Transmission/Reception • Built-In Keypad For Standalone Operation. • Lcd Display Module (128 × 64) For Menu And Status Display. • On-Board Microcontroller-Based Control Section. Software Support: • At Command Execution And Monitoring Software. • Sim Manager Utility Software. • Data Logging And Communication Terminal Utility. • Pc-Based Gui Software For Sim Data Communication Experiments. Trainer Features: • Fault Simulation Facility For Troubleshooting Experiments. • Simulation Of Faults Such As: • Sim Not Detected • Clock Failure • Vcc Failure• Reset Failure • Multiple On-Board Test Points For Signal Observation. • Test Points For: •Sim_Rst• Sim_Clk • Sim_Io • Vcc • Uart Tx/Rx • Suitable For Cro/Dso Signal Monitoring.• Glass Epoxy Pcb With Educational Block Diagram Layout. • Compact Tabletop Enclosed Cabinet Design. Construction: • Front Panel With Printed Block Diagram.• Banana Test Points And Patching Facility. Standard Accessories: • Gsm Sim Trainer Unit. • Usb Communication Cable. • Rs-232 Communication Cable. Power Cord.• User Manual.• Utility Software Cd / Downloadable Software Package.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
15.
Health and Family Welfare #11425228 AOC
Procurement And Supply Of Certain Furniture Items For Telangana Diagnostic Hub At Nagarkurnool In Nagarkurnool District-1.00 Reception Table 1500 Mm X 900 Mm With 18Mm Prelaminated Board With 8 Mm Glass Front Side With Telangana Logo With Two Individual Key Boards, Including Cost And Conveyance Of All Material To Site, Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply. 8.00 Procurement And Supply Of High Rise Revolving Chair, With Bottom Of Round Balancing Surface Of Chair With Stainless Steel Material Along With Foot Rest, Ss Supporting Handles Along With Back Support In Semi -Arc Shape Covering Lether And Soft Material At Back Support Including Cost And Conveyance Of All Material To Site, Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply. 2.00 Office Table Of Size 4’X2’X30” With Three Draw Unit Of Size 350 ( W ) X 430 ( H ) X 560 ( D ) Mm In 0.6Mm Thickness And Front Cover In 0.6Mm Thick Crca Sheet ( Tata Of Sail ) With 6 Lever Lock With Plastic Handle. Table Top Made Of 18Mm Thick Pre-Laminated Board ( Plb ) With 2Mm Thick ( Edge Banding ) . The Under Structure Will Have Top Frame Of C Section 35X20x20mm In 16 Gauge Stand Of 4 Legs Connected With One Horizontal Supports In 16 Gauge Thick 1” Square Hr Tube, With 3 In One Chemical Cleaning Will Be Pre-Treated And Epoxy Powder Coated Paint 50-60 Microns, Along With Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric, Including Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply. 2.00 Computer Table Of Size 1200 Mm X 900 Mm Prelaminated Board, Left Side One Draw With One Cupboard With Locking System And Right Side Cpu Provision With Keyboard Along With Computer Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric, Including Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply.
Contract Date: Ref. Documents Contract Value : 1.18 Lakh
Government Departments No of Bidders 1
16.
Health and Family Welfare #11425225 AOC
Procurement And Supply Of Certain Furniture Items For Telangana Diagnostic Hub At Wanaparthy In Wanaparthy District-1.00 Reception Table 1500 Mm X 900 Mm With 18Mm Prelaminated Board With 8 Mm Glass Front Side With Telangana Logo With Two Individual Key Boards, Including Cost And Conveyance Of All Material To Site, Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply. 8.00 Procurement And Supply Of High Rise Revolving Chair, With Bottom Of Round Balancing Surface Of Chair With Stainless Steel Material Along With Foot Rest, Ss Supporting Handles Along With Back Support In Semi -Arc Shape Covering Lether And Soft Material At Back Support Including Cost And Conveyance Of All Material To Site, Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply. 2.00 Office Table Of Size 4’X2’X30” With Three Draw Unit Of Size 350 ( W ) X 430 ( H ) X 560 ( D ) Mm In 0.6Mm Thickness And Front Cover In 0.6Mm Thick Crca Sheet ( Tata Of Sail ) With 6 Lever Lock With Plastic Handle. Table Top Made Of 18Mm Thick Pre-Laminated Board ( Plb ) With 2Mm Thick ( Edge Banding ) . The Under Structure Will Have Top Frame Of C Section 35X20x20mm In 16 Gauge Stand Of 4 Legs Connected With One Horizontal Supports In 16 Gauge Thick 1” Square Hr Tube, With 3 In One Chemical Cleaning Will Be Pre-Treated And Epoxy Powder Coated Paint 50-60 Microns, Along With Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric, Including Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply. 2.00 Computer Table Of Size 1200 Mm X 900 Mm Prelaminated Board, Left Side One Draw With One Cupboard With Locking System And Right Side Cpu Provision With Keyboard Along With Computer Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric, Including Labour Charges Supply To Site Including All Taxes ( Gst ) Complete For Finished Item Of Work. With 3 Years Warranty From The Date Of Supply.
Contract Date: Ref. Documents Contract Value : 1.18 Lakh
Government Departments No of Bidders 1
17.
Health and Family Welfare #11425224 AOC
Procurement And Supply Of Certain Furniture For D-Hub Peddapally In Peddapally District-1.00 Reception Table With Chai Reception Table 1500 Mm X 900 Mm With 18Mm Prelaminated Board With 8 Mm Glass Front Side With Telangana Logo With Two Individual Key Boards Providing Computer Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric.Providing Computer Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric Inclusive Of Gst @ 18% With 3 Years Warranty From The Date Of Supply 8.00 High Rise Chairs High Rise Chair Of Size 48.3D X 52.1W X 81.3H Centimeters With A Built In 360 Degree Swivel Of Seat Height 58.42 Centimetres, Seat Width 38.1 Centimetres With Foot Rest Inclusive Of Gst @ 18% With 3 Years Warranty From The Date Of Supply 2.00 Consultant Table With Chair Office Table Of Size 4’X2’X30” With Three Draw Unit Of Size 350 ( W ) X 430 ( H ) X 560 ( D ) Mm In 0.6Mm Thickness And Front Cover In 0.6Mm Thick Crca Sheet ( Tata Of Sail ) With 6 Lever Lock With Plastic Handle. Table Top Made Of 18Mm Thick Pre-Laminated Board ( Plb ) With 2Mm Thick ( Edge Banding ) . The Under Structure Will Have Top Frame Of C Section 35X20x20mm In 16 Gauge Stand Of 4 Legs Connected With One Horizontal Supports In 16 Gauge Thick 1” Square Hr Tube, With 3 In One Chemical Cleaning Will Be Pre-Treated And Epoxy Powder Coated Paint 50-60 Microns. Providing Computer Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric. Inclusive Of Gst @ 18% With 3 Years Warranty From The Date Of Supply 2.00 Computer Table With Chair Computer Table Of Size 1200 Mm X 900 Mm Prelaminated Board, Left Side One Draw With One Cupboard With Locking System And Right Side Cpu Provision With Keyboard And Providing Computer Chair / Revolving Malaysian Medium Back Chair Seat And Back Moulded Rubber Foam With Pu Handles With Syncro Hydraulic Gas Lift And Tilting System And Pu Base With 5 Wheels Locking System With Fabric. Inclusive Of Gst @ 18% With 3 Years Warranty From The Date Of Supply
Contract Date: Ref. Documents Contract Value : 1.24 Lakh
Government Departments No of Bidders 1
18.
Public Administrative Department #11418998 AOC
Tender For General-Aroor Gp 2024-25 Pro.No-145/25-Additional Construction In Mcf-General Civil Work - Constraction for machine Room 2 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 3 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 4 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 5 OD304174/2024-2025:Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site 6 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 7 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 8 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 9 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 10 5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars 11 50.2.25.1:Filling with contractors own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge 12 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 13 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 14 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 15 12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) 16 16.71:Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer - in- Charge. 17 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete 18 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 19 13.3.2:20 mm cement plaster of mix:1:6 ( 1 cement : 6 fine sand) 20 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 21 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 22 10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 23 10.7:Providing and fixing ball bearing for rolling shutters. 24 10.8.1:Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area 25 4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 26 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 27 51.2.3:Filling with Quarry Muck
Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade 28 16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 29 16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 30 50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete 31 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 32 9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
Contract Date: Jun 30, 2026 Contract Value : 21.18 Lakh
Government Departments No of Bidders 2
19.
Public Administrative Department #11417601 AOC
Tender for Annual Tender 2026-2027 - Supply Of Electrical Goods In The Year 2026-2027 In Panagudi Town Panchayat , 1X40 W Tube Light , 1X40 W Copper Chocke , 1X40 W Tube Light Starter , Tube Light Side Holder , 4Ft.Alu.Street Light Fittings And Chock ,Starter Without Lamp , Fittings Side Tagged , Bulb Upto 100 W , Bulb Holder , Fittings Top Clamp , Insulation Pvc Taproll (10 Mtr) , 250 W Sodium Vapour Lamp , 250 W Sodium Vapour Choke , 250 W Sodium Condenser (33Mfd) , 250 W Sodium Vapour Ignator , 250 W S.V. Lamp Holder , 250 W S.V.Fittings Complete Set (Without Lamp) , 150 W Sodium Vapour Lamp , 150 W S.V.Chocke , 150 W S.V.Condencer , 150 W S.V.Ignator , 150 W S.V.Fittings , 150 W S.V.Holder , 70W S.V.Lamp , 70W S.V.Chocke , 70W S.V.Condencer , 70W S.V.Ignator , 70W S.V.Fittings , 70W S.V.Holder , 125 W M.V.Chocke , 125 W M.V.Condencer , 125 W M.V.Holder , 125 W M.V.Lamp , 1X40 Watts Heavy Duty Electronics Chocke , 400 W M.H.Lamp , 400 W M.H.Chocke , 400 W M.H Ignator , 400 W M.H.Condencer , 400 W M.H Flood Light Fittings , 400 W M.H Control Gear Box , 250 W M.H. Lamp , 250 W M.H.Chocke , 250 W M.H Ignator , 250 W M.H.Condencer , 250 W M.H.Fittings , 150 W M.H.Lamp , 150 W M.H.Chocke , 150 W M.H.Ignator , 150 W M.H Condencer , 150 W M.H.Fittings , 70W M.H.Lamp , 70W M.H.Chocke , 70W M.H.Fittings , 1/18 Pvc Copper Wire (90 Mtr) , 3/20 Pvc Copper Wire (90 Mtr) , 7/20 Pvc Copper Wire (90 Mtr) , 7/18 Vir Copper Wire (90 Mtr) , 7/16 Pvc Copper Wire (90 Mtr) , Hookup Wire (90 Mtr) , 1.5 Sqr Mm Alu. Wire (90 Mtr) , 3/20 Pvc Aluminium Wire (90 Mtr) , 7/20 Pvc Aluminium Wire (90 Mtr) , 18 Pvc Aluminium Wire (90 Mtr) , 7/16 Alu.Pvc Wire (90 Mtr) , Silk Wire 2Core Copper , S.V.Clampset With Bend Pipe , T5 Fitting Clampset, Bend Pipe With Wire , Cfl Fittings Clampset With Bend Pipe , St.Light Clampset Bend Pipe , Sodium Vapour Acurlic Cover , St.Light Fittings Acurlic Cover , Cfl Acurlic Cover , St. Light Automatic On/Off Digital Timer Control Panel Board With 40Amps Contactor.. , St. Light Automatic On/Off Mechanical Timer Control Panel Board With 40Amps Contactor. , 7 Days Mechanical Clock , Electronics 7 Days Digital Clock , Electronics 7 Days Clock Battary , 40Amps Contactor Control Switch , Contactor Coil 220V-250V , St.Light Switch Box, Main,Clampset With Service Pipe , T5 2X24 Watts Power Saver Chock. , T5 Power Saver Lamp 24 Watts , 2X24 Watts T5 Flourescent Power Saver Street Light Alu. Die Cast Fittings(Ip 65) With Lamps. , 2X14 Watts T5 Flourescenr Power Saver Street Light Alu Die Cast Fittings(Ip 65) With Lamps. , 4X24w T5 Flourescent Power Saver Alu Fitting, Chock With Lamps. , T5 Power Saver Patt Fittings With Lamp 28Watts , 36W Compact Flourescent Lamp(Cfl). , 36Watts Cfl Chocke , 1X36 Watts Compact Flourescent Lamp (Cfl) Fittings, Industrial Electronics Type Chock Withlamp , 2X36 Watts Alu St. Light Compact Flourecent Lamp(Cfl) Fittings, Industrial Electronics Type Chock Withlamp . , Fan (Crompton) , Gi Wire 7/20. , Gi Wire 20 No. , Hand Clous Set , Solar Light Post 11Watts Cfl With All Accessories Complete Set , D.P Switch 32A/240V , Solar Light Post 15Watts Led With All Accessories Complete Set , Solar Light Post 20 Watts Led With All Accessories Complete Set , Solar Light Post 10Watts Led With All Accessories Complete Set , Cfl 20 Watts Direct , Cfl 15 Watts Direct , Fuse Unit 16/240 Volt , Fuse Unit 16/415 Volt , Fuse Unit 32/415 Volt , Fuse Unit 63/415Volt , Fuse Unit 100/415 Volt , Fuse Unit 200/415 Volt , Fuse Unit 400/415 Volt , Main Switch 16/240 Volt , Main Switch 32/240 Volt , Main Switch 32/415 Volt , Main Switch 63/415 Volt , Main Switch 100/415 Volt , Main Switch 200/415 Volt , Single Pole Mcb , 4Pole Mcb , Mcb Box , 20 W Led Street Light Luminaire Comprising Of Epoxy Power Coated Hsg. Enclosed With Glass Cover In Frame. , 24 W Led Street Light Luminaire Comprising Of Epoxy Power Coated Hsg. Enclosed With Glass Cover In Frame. , 30 W Led Street Light Luminaire Comprising Of Epoxy Power Coated Hsg. Enclosed With Glass Cover In Frame. , 48W Led Street Light Luminaire Comprising Of Epoxy Powder Coated Hsg. Enclosed With Glass Cover In Frame. , 50W Led Street Light Luminaire Comprising Of Epoxy Powder Coated Hsg. Enclosed With Glass Cover In Frame. , 72W Led Street Light Luminaire Comprising Of Epoxy Powder Coated Hsg. Enclosed With Glass Cover In Frame. , 90W Led Street Light Luminaire Comprising Of Epoxy Power Coated Hsg. Enclosed With Glass Cover In Frame. , 100W Led Street Light Luminaire Comprising Of Epoxy Power Coated Hsg. Enclosed With Glass Cover In Frame. , 120W Led Street Light Luminaire Comprising Of Epoxy Powder Coated Hsg. Enclosed With Glass Cover In Frame. , 200W Led Street Light Luminaire Comprising Of Epoxy Powder Coated Hsg. Enclosed With Glass Cover In Frame. , 24W Led Chip , 48W Led Chip , 50W Led Chip , 72W Led Chip , 90W Led Chip , 100W Led Chip , 120W Led Chip , 200W Chip , 24W Led Driver , 48W Led Driver , 50W Led Driver , 72W Led Driver , 90W Led Driver , 100W Led Driver , 120W Led Driver , 200W Led Driver , Solar Light Post 15Watts Led With All Accessories Complete Set , Solar Light Post 20 Watts Led With All Accessories Complete Set , Solar Light Post 10Watts Led With All Accessories Complete Set , 2X24w Industrial Electronic Choke , 2X36w Cfl Choke , 1X36 Industrial Cfl Choke , 4 Pin Cfl Holder , 24W T5 Holder , 100*120 Capacitor , 50Mfd Capacitor , 20W Led Tube Set (Wall Fittings) , 40W Flouresent Tube Set (Wall Fittings)
Contract Date: Jun 30, 2026 Contract Value : 8.90 Lakh
Local Bodies No of Bidders 3
20.
Educational and Research Institute #11408306 AOC
Bids Are invited for Providing and fixing 22.8 mm thick panels with bottom metal screen, intermediate fabric screens, and top screen in fabric magnetic finish, complete in all respects. Providing and placing NOVA make or equivalent free-standing pedestal with flat metal front of size 390 mm (W) × 435 mm (D) × 646 mm (H), comprising one drawer (1 box + 1 file) with central locking system, complete with all fittings and accessories. Providing and fixing Keyboard Platform Tray (KBPT) with integrated mouse tray, suitable for the workstation, complete in all respects. The complete workstation system shall be Greenguard (UL) certified and BIFMA LEVEL 2 certified. The manufacturer shall possess valid certifications of ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA, as applicable.The work includes transportation, loading, unloading, fixing, alignment, leveling, testing and commissioning, complete, as per approved drawings, specifications and directions of the Engineer-in-Charge , Supplying and placing in position executive main table with ERU and integrated pedestal of overall size 2350 × 2350 × 750 mm (H), comprising primary and secondary work surfaces made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998, finished with 0.4 mm thick PVC membrane pressed on top, complete with soft-closing access flap and in-built power box for cable management. The modesty panel shall be of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998, finished with 0.4 mm thick PVC membrane pressed on top.The under-structure and integrated pedestal shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, conforming to IS:12823-1990, of approved shade, with all exposed edges edge-banded with matching 2 mm thick PVC lipping. The pedestal shall be of BOX-BOX-FILE configuration, having powder-coated metal panel drawer slides of 400 mm length with 325 mm drawer extension, provided with soft-closing and anti-slam mechanism, suitable handles, and central locking system, complete in all respects. The product shall be GREENGUARD (UL) certified, Indoor Advantage GOLD and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications. The item includes transportation, loading, unloading, fixing, alignment and making functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position back unit of overall size 2350 × 500 × 1800 mm (H), complete in all respects, having top panel made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823-1990, with all exposed edges edge-banded with matching 2 mm thick PVC lipping, sliding door storage unit with body panels including sides, bottom, back and shelves made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick matching PVC edge banding, shutters made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, provided with soft-closing and anti-slam mechanism, suitable handles and locking arrangement, display/storage unit made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick PVC lipping for sides, back and shelves, doors made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, and top panel of display unit also made of 25 mm thick MDF finished similarly, the complete unit being GREENGUARD (UL), Indoor Advantage GOLD and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position high back executive chair, complete in all respects, having cushioned seat made of injection-moulded plastic outer and inner, inner upholstered in pure leather with moulded High Resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf at 25% compression, cushioned back made of PU foam with in-situ moulded M.S. E.R.W. round tube of size 1.9 ± 0.03 cm dia × 0.16 ± 0.0128 cm thick, upholstered in pure leather, seat size 47.6 cm (W) × 49.2 cm (D) and back size 47.5 cm (W) × 77.0 cm (H), PU moulded armrest tops upholstered in pure leather mounted on drop-lift adjustable M.S. E.R.W tubular arm supports of size 3.81 ± 0.03 cm × 0.2 ± 0.01 cm thick with chrome-plated finish, height adjustable up to 6.5 ± 0.5 cm in five steps, provided with active bio-synchro mechanism having 360° revolving, front-pivot tilt with continuous lumbar support, tilt tension adjustment operable in seating position, five-position tilt limiter and seat/back tilting ratio of 1:2, mechanism housing made of HPDC aluminium black powder-coated, provided with seat depth adjustment through integrated sliding mechanism with adjustment range of 6.0 ± 0.5 cm, adjustable back support through up/down mechanism housed in plastic T-spine with adjustment range of 7.42 ± 0.5 cm, pneumatic height adjustment with stroke of 10.0 ± 0.3 cm, pedestal made of high-pressure die-cast polished aluminium fitted with five twin-wheel castors of injection-moulded black polypropylene, pedestal pitch-centre dia 65.0 ± 0.5 cm (75.0 ± 1.0 cm with castors), overall seat height 44.5 to 54.5 cm, overall height 114.0 to 131.5 cm and overall width and depth 76.1 cm each, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position visitor chair, complete in all respects, having cushioned seat made of injection-moulded plastic outer and inner, inner upholstered in pure leather with moulded High Resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf at 25% compression, cushioned back made of PU foam with in-situ moulded M.S. E.R.W. round tube of size 1.9 ± 0.03 cm dia × 0.16 ± 0.0128 cm thick, upholstered in pure leather, seat size 47.6 cm (W) × 49.2 cm (D) and back size 46.5 cm (W) × 59.5 cm (H), provided with cantilever type tubular frame made of SS-202 tube of size Ø 2.54 ± 0.03 cm × 0.02 ± 0.016 cm thick, back connected to frame through chrome-plated high-pressure die-cast connector, overall seat height 46.2 cm, overall height 98.2 cm, overall width 60.9 cm and depth 64.7 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Supplying and placing in position main table of overall size 1800 × 900 × 750 mm (H), complete in all respects, having work surface made of a combination of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, and 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823-1990, with all exposed edges edge-banded with matching 2 mm thick PVC lipping, provided with soft-closing access flap and in-built power box on work surface for wire management, modesty panel made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, under-structure made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick matching PVC lipping, integrated pedestal made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick PVC edge banding, drawer fronts made of 25 mm thick MDF one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, pedestal of BOX-BOX-FILE configuration using powder-coated metal panel drawer slides of 400 mm length with 325 mm drawer extension, provided with soft-closing and anti-slam mechanism, suitable handles and locking arrangement for security, the product being GREENGUARD (UL) certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position mid back chair, complete in all respects, having seat made of 1.5 ± 0.1 cm thick hot-pressed plywood upholstered with fabric upholstery covers and moulded polyurethane foam, with extra thick foam at the front edge for comfort to the popliteal area, back made of injection-moulded glass-filled polypropylene upholstered with mesh fabric and provided with adjustable lumbar support made of injection-moulded polypropylene with adjustment range of 5.0 ± 0.1 cm, seat size 53.5 cm (W) × 51.0 cm (D) and mesh back size 51.0 cm (W) × 70.0 cm (H), seat foam of High Resilience (HR) polyurethane moulded with density 45 ± 2 kg/m³ and hardness 16 ± 2 kgf as per IS:7888 at 25% compression, provided with adjustable armrests having up-down adjustment in six steps (7.2 ± 0.5 cm range) with armrest top PU-moulded over glass-filled nylon insert and mounted on armrest structure made of glass-filled nylon, provided with centre tilt synchro mechanism with multi-lock having 360° revolving, three-position locking with anti-shock mechanism and tilt tension adjustment, pneumatic height adjustment with stroke of 9.5 ± 0.3 cm, pedestal assembly made of injection-moulded glass-filled nylon fitted with five twin-wheel castors, pedestal pitch-centre diameter 66.1 ± 0.5 cm (76.1 ± 1.0 cm with castors), twin-wheel castors injection-moulded in black nylon, overall width 76.1 cm, depth 76.1 cm, height 101.5 to 111.0 cm and seat height 44.5 to 54.0 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position visitor chair, complete in all respects, having single shell seat and back made of 1.2 ± 0.1 cm thick hot-pressed plywood, upholstered with moulded polyurethane foam on top and backing foam on rear side, finished with knitted fabric or leatherette upholstery, with extra thick foam at the front edge for comfort to the popliteal area, High Resilience (HR) polyurethane foam for seat and back moulded with density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf as per IS:7888 at 25% compression, provided with cantilever type visitor tubular frame made of M.S. E.R.W. tube of size Ø 2.54 ± 0.03 cm × 0.2 ± 0.016 cm thickness, powder coated finish of DFT 40–60 micron, armrest tops moulded from polyurethane (PU) with metal insert and mounted on tubular frame, overall width 60.5 cm, depth 65.0 cm, height 86.5 cm and seat height 46.0 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position ergonomic task chair, complete in all respects, having cushioned seat assembly with seat base moulded in glass-filled poly-amide, moulded polyurethane foam upholstered with high-stretch knitted polyester fabric, back injection-moulded in glass-filled polypropylene upholstered with mesh fabric and provided with adjustable lumbar support made of injection-moulded polypropylene with adjustment range of 3.0 ± 0.1 cm, mesh back size 45.5 cm (W) × 54.0 cm (H) and seat size 48.5 cm (W) × 49.0 cm (D), High Resilience (HR) polyurethane foam used in seat and back cushions moulded with minimum density 48 kg/m³ and hardness load 15 ± 2 kgf as per IS:7888 at 25% compression, seat and back firmly connected to base frame and cantilevered to allow multi-dimensional movement with impact cushioning and synchronized seat-back motion during posture changes, back-spine structure comprising “S” shaped spines and spine connector moulded in high-strength glass-filled poly-amide, provided with variable tilt angle recline adjustable through three-position tilt limit feature inbuilt in seat base with user-weight dependent return force, armrest assembly consisting of armrest housing sliding over armrest structure both moulded in glass-filled poly-amide, with button-operated height adjustment of 6.6 ± 0.5 cm, armrest top of integral skin PU moulded over plastic inner moulded in glass-filled poly-amide, pneumatic gas-lift height adjustment with stroke of 9.2 ± 0.3 cm, pedestal made of injection-moulded glass-filled poly-amide having pitch-centre diameter 66.0 ± 0.5 cm (76.0 ± 1.0 cm with castors), fitted with five twin-wheel castors injection-moulded in poly-amide of 5.0 ± 0.1 cm wheel diameter, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position high back chair, complete in all respects, having cushioned seat assembly with seat base moulded in glass-filled poly-amide, moulded polyurethane foam upholstered with high-stretch knitted polyester fabric, cushioned back assembly with back inner moulded in polypropylene, in-situ moulded with polyurethane foam and upholstered with high-stretch knitted polyester fabric, seat size 48.5 cm (W) × 47.0 cm (D) and back size 45.5 cm (W) × 53.0 cm (H), High Resilience (HR) polyurethane foam used in seat and back cushions moulded with minimum density 48 kg/m³ and hardness load 15 ± 2 kgf as per IS:7888 at 25% compression, seat and back firmly connected to base frame and cantilevered to provide multi-dimensional movement, impact cushioning while sitting and synchronized seat-back movement during posture changes, back-spine structure comprising “S” shaped spines and spine connector moulded in high-strength glass-filled poly-amide, provided with variable tilt angle recline adjustable through three-position tilt limit feature inbuilt in seat base with user-weight dependent return force, adjustable armrests comprising armrest housing sliding over armrest structure both moulded in glass-filled poly-amide with button-operated height adjustment of 6.6 ± 0.5 cm, armrest top of integral skin PU moulded over plastic inner moulded in glass-filled poly-amide, pneumatic gas-lift height adjustment with stroke of 9.2 ± 0.3 cm, pedestal assembly made of injection-moulded glass-filled poly-amide having pitch-centre diameter 66.0 ± 0.5 cm (76.0 ± 1.0 cm with castors), fitted with five twin-wheel castors injection-moulded in poly-amide of 5.0 ± 0.1 cm wheel diameter, overall seat height 44.5 to 53.8 cm, overall height 99.5 to 108.8 cm and overall width and depth 76.0 cm each, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Supplying and placing in position 24-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position 16-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge , Supplying and placing in position 12-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supply and fixing wooden storage unit of size 1200 × 450 × 1219 mm (H), complete in all respects, comprising low to medium height HDU, with body made of 18 mm pre-laminated board (PLB) with all edges sealed with 0.8 mm thick PVC edgeband, back panel made of 9 mm white pre-laminated board (PLT), complete ready-to-assemble construction using suitable knock-down (KD) fittings, shelves and separator panels (where provided) made of 18 mm white PLT with 0.8 mm edge banding, bottom shelf fixed and other shelves with one-step adjustable positions for optimized storage, door panels made of 18 mm PLB with 2 mm edge banding on all edges, fitted with flush plastic handle vertically at center, doors mounted on suitable hinges with HDU fitted with adjustable height fittings, three-point locking arrangement provided, and all units fitted with 6 mm levelers at the bottom for proper leveling, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position one-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 86.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position two-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 172.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position three-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 206.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position three-seater sofa, complete in all respects, overall dimensions width 176.5 cm, depth 81.5 cm, height 83.5 cm, upholstered in PVC material of 1 mm thickness in coffee brown shade, frame made of pine wood with moisture content 10–12%, plywood used in frame 12 mm and 18 mm thick, seat cushion made of slab stock foam with density 32 kg/m³, back and armrest cushions filled with conjugated hollow fiber (recron), webbing made of nylon, legs made of PVC, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position coffee table, complete in all respects, overall size 1202 × 594 × 411 mm (W × D × H), body made of 18 mm pre-laminated particle board (PLB) with all exposed edges edge-banded with 2 mm thick PVC, middle horizontal panel providing storage area, four nylon bushes provided, top comprising 8 mm thick toughened glass glued with UV plate and PLT panel, glass fixed to side vertical panels, PLT top panel hinged to side vertical panels to open upwards, knock-down construction, finish in WENGE shade with suede finish on PLT panels and Sunray finish on UV-glued plates under glass, hardware comprising dowels for knock-down assembly with high-quality standard hardware including screws, door hinges, bumpers, expanding sockets, nylon bushes, etc., including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position coffee table, complete in all respects, overall size 1100 × 600 × 456 mm (L × W × H), table-top made of 8 mm thick toughened clear glass, body made of 18 mm thick pre-laminated board (PLT) in Cincinnati Walnut finish, configuration comprising shelf storage and display space, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position corner table, complete in all respects, overall size 450 × 450 × 606 mm (L × W × H), table-top made of 6 mm thick toughened clear glass, body made of 18 mm thick pre-laminated board (PLT) in Cincinnati Walnut finish, configuration comprising shelf storage and display space, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position corner table, complete in all respects, overall dimensions 60 × 45 × 60 cm (W × H × D), made of 18 mm thick pre-laminated particle board (PLB) with 10 mm thick toughened glass top, construction knock-down type, finish comprising MIP lamination in Black Ink shade with matching matt PVC lipping and digitally printed glass matching the PLB finish, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position main table of overall size 1220 × 600 × 750 mm (L × W × H), complete in all respects, work surface made of 25 mm thick pre-laminated board of E1-P2 grade of approved shade conforming to IS:12823:1990, all exposed edges edge-banded with 2 mm thick PVC lipping, access flap provided on work surface for wire management, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick PVC lipping, cube legs fabricated from MS ERW tube 50 × 25 × 1.2 mm and 40 × 40 × 1.2 mm as per IS:7138, top of legs welded with 3 mm thick HR steel support brackets (IS:2062) for fixing worktop, welded structure coated with 50 micron epoxy polyester, base fitted with plastic cap with M8 molded insert and straight M8 leveler adjustable up to 50 mm, cross members made from 50 × 25 × 1.2 mm ERW tube (IS:7138), coated with 50 micron epoxy polyester, assembled by friction-fit PDC joinery and grub screws, two cross members per table, power box made of 0.8 mm thick CRCA (IS:513) with 8-module Anchor Roma cutout fixed along the depth of worktop, soft-closing access flap made of aluminum extrusion with PDC parts in aluminum alloy and plastic parts in Nylon 6, wire brush with nylon bristles for cable management, the product being GREENGUARD (UL) certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing and placing in position high-back (HB) chair, complete in all respects, with cushioned seat made of injection-molded plastic outer and inner, inner upholstered with leatherette and moulded high resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression; cushioned back made of PU foam with in-situ molded MS ERW round tube 1.9 ± 0.03 cm × 0.16 ± 0.0128 cm, upholstered with leatherette, seat size 47.0 × 48.0 cm (W × D), high-back size 47.7 × 76.4 cm (W × H); armrest top moulded in PU, mounted on drop-lift adjustable tubular support of 3.81 ± 0.03 cm × 0.2 ± 0.01 cm MS ERW tube with chrome finish, height adjustable up to 6.5 ± 0.5 cm in 5 steps; active bio-synchro mechanism with 360° revolving type, front-pivot tilt with feet resting on ground, continuous lumbar support, tilt tension adjustable in seating position, 5-position tilt limiter, seat/back tilting ratio 1:2, mechanism housing of HPDC aluminium black powder coated, seat depth adjustable 6.0 ± 0.5 cm, adjustable back support connected to Up/Down mechanism housed in plastic T-spine adjustable 7.42 ± 0.5 cm, pneumatic height adjustment stroke 10.0 ± 0.3 cm, pedestal of high-pressure die-cast polished aluminium fitted with 5 twin-wheel castors, pedestal pitch-center diameter 65.0 ± 0.5 cm (75.0 ± 1.0 cm with castors), twin-wheel castors injection-moulded black PP, wheel diameter 6.0 ± 0.1 cm, overall chair dimensions: seat height 43.1–53.1 cm, height 112.7–130.2 cm, width & depth 76.1 × 76.1 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, certified Greenguard (UL) and BIFMA LEVEL 2, manufacturer holding ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. Total Quantity : 172
Contract Date: Ref. Documents Contract Value : 42.59 Lakh
Government Departments No of Bidders 5
22.
Defence #11403945 Price Bid
Tender for Contract Details , Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For Any Work As Directed And Specified . , M&L For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Roof Padding, 40Mm Thick, Finished The Surface Fair And Even All As Specified And As Directed. , M&L For Screeding 10Mm Thick In Cm 1:4 Using Water Proofing Compound, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. Note:- Water Proofing Compound Shall Be Measured And Paid Separately Under Respective Item Of Sch A (Boq). , Supplyt Only Liquid Water Proofing Compound Complete All As Specified And As Directed , Material And Labour For App Based Polymeric Water Proof Membrane, Minimum 3 Mm Thick And Weighing Not Less Than 3.6 Kg Per Square Metre, Black Finish Reinforced With Non Woven Polyster Matt With Thermo Finish Laid Over Compatible Bitumen Primer @ 0.30 Liters Per Square Metre And Applying A Layer Of Blown Grade Bitumen (Conforming To Is -702) 85/25 @ 1.20 Kg/Sqm With Help Of Torching With A Proplane Or A Butane Gas Using Torch With Minimum Overlap Of 75 Mm At Side And 100 Mm At Ends And Sealing Including Applying A Coat Of Cold Emulsion Bituminous Primer All As Per Manufacturers Instructions.Complete All As Specified And As Directed. For Parapet The Membrane Will Be Taken To A Height Of 30 Cm And Then Inserted Inside The Parapet In A Groove (No Separate Payment Will Be Made And The Measurement Will Be Done For Horizontal Surface ).Including Applying A Coat Of 85/25 Penetration Industrial Bitumen Over Top Surface @ 1.2 Kg/Sqm And Binding Materials Such As Sand In Dry Condition @ 0.5 To 1.00 Kg/Sqm Shall Be Dusted Over The Bitumen Complete All As Specified And As Directed. (Note :- 1. App Based Polymeric Water Proofing Membrane Shall Be Purchased Directly From The Manufacturer Or Their Authorized Distributors) . , Taking Up Or Down Steel Tubing 15Mm Bore And Connection Including Cleaning For Refixing Complete All As Specified And Directed. , Refixing Old Serviceable 15 Mm Gi Tubing And Connection In New Or Old Position (Wall, Ceiling Floor Etc.) Including Necessary Fittings&Fixtures Ie. Union, Nipple, Socket Etc. Complete All As Specified And Directed , Supply And Fix 15 Mm Bore Medium Grade Galvanised Steel Tubing With All Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floor Complete Incl Ie. Union, Nipple, Socket Etc. All As Specified And Directed. , Taking Up Or Down Steel Tubing 20Mm Bore And Connection Including Cleaning For Refixing Complete All As Specified And Directed. , Refixing Old Serviceable 20 Mm Gi Tubing And Connection In New Or Old Position (Wall, Ceiling Floor Etc.) Including Necessary Fittings&Fixtures Ie. Union, Nipple, Socket Etc. Complete All As Specified And Directed , Supply And Fix 20Mm Bore Medium Grade Galvanised Steel Tubing With All Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floor Complete Incl Ie. Union, Nipple, Socket Etc. Complete All As Specified And Directed. , Supply And Fix For 1000 Litre Capacity Rotational Moulded Polythylene Water Storage Tanks (Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Including Dismantling Of Existing Water Tanks Of Syntax Complete All As Specified And Directed. , Supply And Fix For 500 Litre Capacity Rotational Moulded Polythylene Water Storage Tanks (Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Including Dismantling Of Existing Water Tanks Of Syntax Complete All As Specified And Directed. , S&F In Repairs Vitreous China Wash Hand Basin, White, Size 550 X 400 Mm Including Brackets, Chromium Placted Waste Coupling &Pvc Waste Pipe Of 32 Mm Dia Complete All As Specified & Directed. , S&F In Repair For 15 Mm Bore Dia Of Pipe Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe And Fixed (Min Weight 20Mm - 210 Gms) Comnnection Complete All As Specified , S&F In Repair For 20 Mm Bore Dia Of Pipe Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe And Fixed (Min Weight 20Mm - 210 Gms) Comnnection Complete All As Specified , S&F (In Repair) 15 Mm Bore Fancy Type Long Body Bib Taps Brass Chromium Plated Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Flench Complete All As Specified & Directed. , S&F (In Repair) 15Mm Bore Pillar Taps, Brass Chromium Plated, Fancy Type Screwed Down High Pressure With Or Without Lettered, Hot Or Cold With Long Screwed Shanks And Fly Nuts, Screwed To Iron Pipe Complete All As Specified & Directed. , S&F In Repair 15 Mm Dia Chromium Plated Angle Cocks/Stop Valves, Brass, Screwed Down, High Pressure With Crutch Or Butterfly Handle, Flench Screwed Both Ends For Iron Pipe Or For Union Complete All As Specified & Directed. , S&F In Repairs 15 Mm Bore Concealed Stop Cock, Chromium Plated, Long Shank Copper Alloy, Screwed Down With Crutch Or Butterfly Handle Screwed Both Ends Complete All As Specified & Directed. , S&F For 600 X 450 Mm Beveled Edge Mirror Of Selected Quality Glass Mounted On 6Mm Thick Ac Building Board Or Commercial Ply Wood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers In Repairs Complete All As Specified & Directed. , Vitreous China Urinals, Bowl Type (Back Or Corner Wall Type),Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs Withand Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets,Flush Pipe,Grating And Union For Discharge Pipe. (Exclusive Of Fixing Supply Pipe To Flushing Cistern, Trap And Waste Pipe) , M&L 20Mm Granite (Of Any Type) Work (Table Rubbed And Polished) In Steps, Jambs, Pillars, Window-Cills, Cooking Plat Forms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite , Providing Edge Moulding To 18-20Mm Thick Granite Stone Of Counters Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed , M&L For Non - Skid Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:6 Complete All As Specified And Directed , M&L For Glazed Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Vertical Surface 350X 250X 7 Mm/ 450X 350X 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over And Including 10Mm Thick Plaster In Cement Mortar 1:4 Complete All As Specified And Directed , S&F Kitchen Plate Rack In Repair Of Stainless Steel Of Size 720Mm X 600Mm X 230 Mm Made Out Of 1 Mm Thick Steel Sheet Complete All As Specified & Directed. , M&L Complete Removal Of Existing Treatment And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Alkali Resistant Priming Paint. , Cleaning Of Storage Water Tank Of Pvc/Hdpe Exc. 250 Ltrs But N. Exc 500 Ltr Capacity Staged Over Reinforced Cement Concrete Roof/Floor Slab Or Similar Place Inside /Outside Bldgs By Removing Float Valves Carefully, Thoroughly Cleaning The Wall, Floor And Ceiling Of The Tanks, Mouth Of Pipe Etc, Removing The Dirty Water, Sludge And Other Depositions To A Distance Not Exceeding 50 Mtr To Make The Tank Totally Dirtfree And Finally Cleaning The Water Tank With Fresh Water Till Water Becomes Clear To Entire Satisfaction Of Eng-In-Charge And As Specified In Particular Specification And Refixing Of Float Valves All As Specified And Directed , Cleaning Of Storage Water Tank Of Pvc/Hdpe Exc. 500 Ltrs But N. Exc 1000 Ltr Capacity Staged Over Reinforced Cement Concrete Roof/Floor Slab Or Similar Place Inside /Outside Bldgs By Removing Float Valves Carefully, Thoroughly Cleaning The Wall, Floor And Ceiling Of The Tanks, Mouth Of Pipe Etc, Removing The Dirty Water, Sludge And Other Depositions To A Distance Not Exceeding 50 Mtr To Make The Tank Totally Dirtfree And Finally Cleaning The Water Tank With Fresh Water Till Water Becomes Clear To Entire Satisfaction Of Eng-In-Charge And As Specified In Particular Specification And Refixing Of Float Valves All As Specified And Directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Uttarakhand View Result →
23.
Defence #11392755 Technical Bid
Tender for Material And Labour For Plain Cement Concrete 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundation ,Filling And Mass Concrete Complete All As Specified And Directed . , Material And Labour For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc , Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C-1 Using (20Mm Graded Stone Aggregate) As In Bed Blocks For Hold Fast,Coping Errection Of Posts Etc Complete All As Specified And Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) On Slabs Supported On Walls , Beams And Columns In Floors , Roofs,Landings,Balconies, Canopies Deck Slabs, And In Shelves And The Like Complete All As Specified And As Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) Chajja, Facia Etc And The Like Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C0 (Using 12.5Mm Graded Stone Aggregate) As In Filling The Hollow Portion Of Steel Frame Complete All As Specified And Directed. , Supply Only Water Proofing Compound. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specifed And Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour For Form Work On Flat Sides To Soffits Of Suspended Roof Slabs Not Exc 200 Mm Thick (Horizontal Or Sloping), Walls , Beams And Columns In Floors,Landings,Balconies, Canopies Deck Slabs, And In Shelves Rough Finished Surface Of Concrete All As Specified And As Directed. , Material And Labour For Form Work On Flat Sides To Chajja, Fins, Louvers, Fascia Etc Rough Finished Surface Of Concrete All As Specified And As Directed. , Refixing Wooden Or Aluminium Door Shutters Of Any Description Exceeding 1 Sqm But Not Exceeding 2 Sqm Each In The Same Opening After Taking Down, Easing And Adjusting Including Refixing Builders Hardware, Glass Etc As Required And Renewal Of Unserviceable Screws Concrete All As Specified And As Directed. , Supply And Fix For 2Nd Class Hardwood Plain, Solid, Straight Chowkhats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue, Pinned At Joints Complete All As Specified And Directed. , Supply And Fix Factory Made 30 Mm Thick Flush Shutter Solid Core Construction With Block Board Core & Plywood Face Panels Commercial Type On Both Sides Incl 5Mm Thick Teakwood Leaping Alround Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Factory Made Door, 35 Mm Thick, Glazed And Skeleton Shutters, Open Rebated And Prepated To Receive Glass Gauze Etc (With Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Materials And Revated Sash Bars Any Number , Edges Of Framing Plain Chemfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass In Door Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (A) Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Glazed And Skeleton Window Shutter 30Mm Thick, Divided Into Squares, With Plain, Chamfered Or Rounded, Mitred And Rebated Sash Bars, Any Numbers, To Receive Glass, Gauze, Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (B) Complete All As Specified And Directed. , Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Stapple Etc Concrete All As Specified And As Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised , Plate Type ,Stove Enameled Black , With Bright Bolt Not Less Than 12Mm Dia With And Incl Minimum Of 6 Bolts And Nuts ,Four On Bolt Plate And Two On Staple Concrete All As Specified And As Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 100Mm Etc Complete All As Specified And Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 75Mm Etc Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 150 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 100 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 200 Mm Long Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 150 Mm Long Complete All As Specified And Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised Sliding Door Bolts , With Hasp Staple (Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast-Aluminium Ally Complete All As Specified And Directed. , Supply And Fix Powder Coated Three Track Aluminium Sliding Window With Approved Make Of Following Extruded Section Of Anodised Glazed Shutter As Per Standard Engineering Practices Including All Other Accessories Complete Including 4.00 Mm Thick Tinted Glass Panes, Rubber Beading, Mosquito Proofing, Locking System Etc. Complete All As Specified And As Directed. (Refer Jindal Cat M-2014 ) Aluminium Sections : A Series (I) Shutter Bottom & Top :- 37.50 X 15 X 1.3 Mm Thick (20690) (Ii) Shutter Interlock :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iii) Shutter Side (Handle) :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iv) Frame Bottom :- 75 X 26 X 1 Mm Thick (20671) (V) Frame Top And Sides :- 75 X 26 X 1 Mm Thick (20672) , Supply And Fix Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) Or Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/Neoprene Gasket Required (Fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Material And Labour Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.,Complete All As Specified And Directed. , Material And Labour For Mild Steel Conforming To Fe 410-0 Or Fe 310-0 In Framed Work Such As Grills, Gratings, Etc With Ends Of Bars Shouldered And/Or Riveted Or Forged Into Spikes; Framed Guard Bars; Ladders; Railings And Similar Work Complete All As Specified And Directed. , Supply And Fix Box Type Steel Windows With Side Hung Shutters Both Mosquito Proof And Glazed Shutter Including Projecting Type Hinges With Steel Handle And Steel Peg Stay With Glazing Bars And 12 Mm Square Bar Or Ground Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And As Directed. , Supply And Fix Steel Ventilators With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. , Material And Labour For Mild Steel Tmt Bars 10 Mm Dia And Over Cut To Length, Bent To Shape As Required Including Cranking, Bending And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia As In Reinforcement Bar Complete All As Specified And As Directed. , Repairing Of Existing Mild Steel Rolling Shutter Of Any Description Or Any Size Including Replacement Of Damaged Mild Steel Laths, Repairing/ Replacement Of Side Guide Channels, Pipe Shaft, Springs, Ball Bearings, Locking Arrangements, Welding Work, Alingment And Smooth Operation, Including Necessary Nuts, Bolts, Oiling And Greasing, Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Atmospheric Classification Category 3,Four (4) Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed , Material And Labour For Pre- Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Plain Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Pattern Corresponding To Is 15965 : 2012 Of Durability Class 3, Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Having Yield Strength Of 550 Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified Complete All As Specified And As Directed. Note: To Be Executed For Provision Of Ridges And Hips. , Material And Labour For 12 Mm Thick Prelaminated Particle Board Bwp Type Melamine Finished (Both Side) For Fixing The Panel Of The Partition/Door Including Necessary Fittings, Gusket, Angle Cleats, Screw Etc Complete All As Specified And Directed. , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour For Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:4) Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm Thick, In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8Mm Thick Area Of Each Tile Exceeding 0.18 And N.Exc 0.38 Sqm In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exc 0.18 And N.Exc 0.38 Sqm , In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. , Material And Labour For Coloured/ Printed Glazed Ceramic Tiles 7Mm Thick Not Exc 0.15 Sqm In Area In Vertical Surfaces I.E. Dado, Skirting, Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, Laid Over And Including Screed Or Screed Bed 10Mm Thick In Cement Mortar 1:4, Complete All As Specified And As Directed. , Material And Labour For 75Mm Thick Cement Concrete 1:3:6 Type C-2 (Using 40Mm Graded Stone Aggregate ) As In Plinth Protection Complete All As Specified And Directed. , Material And Labour For 100Mm Thick Cement Concrete 1:2:4 Type B-2 (Using 40Mm Graded Stone Aggregate) As In Flooring, Hardstanding Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Material And Labour For 5Mm Thick Rendering On Fair Faces Of Brick Or Concrete Surface In Cm 1:3 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Ceiling Surface And Applying Three Coats Of White Wash Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Figured Glass, Pin Head Type And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For Preparation And Applying Two Coats Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Over A Coat Of Pink Primer Complete All As Specified And Directed. , Material And Labour For Preparation Of Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide On New Steel Surfaces , Over 10 Cm In Width Or Grith Not Other Wise Described Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 15Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 20 Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Hand Basin White, Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Pvc Waste Coupling And 32 Mm Dia Pvc Waste Pipe Including Fixing Of Tap, Waste Fitting Etc Complete All As Specified And Directed. , Supply And Fix In Repair Bib Taps With Wall Flange 15Mm Bore, Fancy Type, Quarter/Half Turn, Brass Chromium Plated, Long Body With Capstan Head And Cup Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Accessories Complete All As Specified And Directed. , Supply And Fix In Repair 125 Mm Dia, Chromium Plated Swivel Type Shower Rose With 195 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15Mm Bore Iron Pipe All As Specified And Directed , Supply And Fix In Repair Bath Wall Mixer With 15Mm Bore (Dia) Spout, Chromium Plated With Long Bend Pipe For Over Head Shower Including Flanges Complete All As Specified And As Directed. , Supply And Fix In Repair Pillar Taps, Cast Copper Alloy, With Capstan Heads, Fancy Type, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered ‘Hot Or ‘Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe 15 Mm Bore Complete All As Specified And Directed. , Supply And Fix In Repair Cp Stop Valve/Angle Valve 15 Mm Bore, Fancy Type Cromimum Plated With Long Shank And Cup (Concealed Type), High Pressure Crutch Or Butter Fly Handle Screwed Both Ends Screwed For Iron Pipe Or For Unions Complete All As Specified And Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 1000 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places With Fittings And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 500 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places Complete And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix Ball Valves 20Mm Bore Dia Of Pipe High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed (Minimum Weight 20Mm-210Gms). , Supply And Fix In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Supply And Fix In Repair Pvc Valve, Symphonic Action Type, Flushing Cistern 10 Liters Capacity Low Level White With Inlet ,Ball Valve ,Float And Handle Including Brocket Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Pvc (Swr) Pipes, Presure Rate Having 6 Kgf Single Socketed In Any Length With Rubber Ring Joints And Laid In Trenches As In Waste/Soil Pipe Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Complete All As Specified And As Directed. , Supply And Fix 75Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Or Floor Complete All As Specified And As Directed. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 75 Mm Bore Complete. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 110 Mm Bore Complete. , Supply And Fix, In Repair Vitreous China Wash Down Water Closet Of Orissa Pattern Size 580 X 440 Mm White With Integral Foot Rests Including Removing Filled Lean Concrete From Sunken Portion And Putting Of Lean Concrete After Treatment Of Sunken Slab, Connection To Trap And To Flushing Pipe Etc Complete And Making Good To Floor Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Down Water Closed Pan (Pedestal Pattern) With P Or S Trap White, Including Connection To Trap And Cistern, Flush Pipe Including White Plastic Water Closet Seat Cover, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Making Good Disturbed Surface Of Floor Complete All As Specified And Directed. , Supply And Fix In Repair Plastic Water Closet Seat Cover, White, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Fixed Wc Pan Complete All As Specified And Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Down Door Chowkhat With Shutter Area N-Exc 1.5 Sqm Each(Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Chowkhats Or Frames With Shutters Exc 1.5 Sqm But Not Exc 4 Sqm Each (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Of Any Description N. Exc 1 Sqm Each Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Any Description Area Exc 1 Sqm And N Exc 2 Sqm Each Complete All As Specified And Directed. , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete (Reinforcement Cut As Required To Facilitate Demolition) Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And As Directed. , Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Or Cement Lime Mortar , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Trusses Etc Complete All As Specified. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc. , Dismantling, Floor Hearth Or Wall Tiling Inclduing Cement Mortar Bedding And Removing Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc. 15 Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , Demolition And Breaking Up Drain Waste Pipes (Sgsw, Ac Or Rcc, Ci ) Of Internal Dia 75/110 Mm, Set In Cement Mortar In Any Position Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
24.
Health and Family Welfare #11383742 AOC
Supply Of Furniture Items To Government Medical College At Suryapet In Suryapet District.=150 Student Cot With Mattress & Pillow 1 Scope: This Specification Is For The Requirement Of Iron Cots Suitable For General Purpose In Hospitals. 1.1 Dimensions 2.1 Over All Dimensions Of Cot Of Size Top Frame ( Sheet ) Shall Be Length 1910 Mm, Width 910 Mm And Height 470 Mm With Bushes. 2.2 The Various Tubes Used In Manufacture Of Iron Cots Should Have The Following Outside Diameter And Thickness. Component Outside Dia ( Mm ) Thickness ( Mm ) A Bows Outer Cr Tubes -38.10.Mm X 1.60Mm B Cross Tubes Cr Tubes 25.40 Mm X 1.22 Mm C Filling Tubes Cr Tubes 19.05 Mm X 1.22 Mm 2.3 The Ms Flat For Top Shall Be Inside All Four Sides Of Size 50X3 Mm Minimum Thickness Of 3.0 Mm. 3 Material: 3.1 Frame Work Shall Be Of Cr Sheets Conforming To Is: 513 D Quality. 3.2 Bows & Tubes: These Shall Be Made From Cr Steel Tubes. 3.3 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. 4 Manufacture 4.1 Head End: Construction Of The Head End Shall Comply To Meet Requirement Given 4.2 Bows Shall Be Manufactured From Steel Tubes. It Shall Be Bent, With Inside Radius Of Not More Than 125 Mm At Top 2 Corners Cr Sheet Brackets . Bracket Of 3 Mm Thickness, Shall Be Welded With The Bows Vertical Upright Members Which Allows Frame To Rest On It An 4.3 Cross Tube: One Horizontal Cross Tube For Making The Structure Of The Bow Rigid Shall Be Welded Between The Vertical Upright Members Of The Bows. Cross Tube Shall Be Welded Below The Sleeping Level At A Height Of 200 Mm From The Bottom. 4.4 Filling Tubes: The Three Vertical Filling Tubes Shall Be Welded To The Cross Tube And To The Bow. They Should Be Spaced At Regular Intervals. The Height Of The Head End Bow Shall Be About 610 Mm. 4.5 Foot End Bow: It Shall Be Similar To 4.1.1 To 4.1.3 Except Leg Bows, Which Shall Be Of 570 Mm Height. 4.6 Mattress Platform: This Shall Comply With The Requirements Given Below:- The Bed Frame Shall Be Made From C.R. Sheet Double Bent. It Should Be Reinforced With Three Formed Channels To Size 20 X 50 X 50 X 50 X 20 Mm Of 1.25Mm Thickness Flanges Welded Inside The Length Wise. With 3 Years Warranty Finish As Per General Condition Of Tender 100 Almarah Steel Full Size Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding &Ark Welding. Anticorrosion Treated Components. Dimensions Outer: 1980 H X 910 W X 480 D Mm Main Door With Shetters Top, Bottom Lh & Rh Sides, Shelves And Back All Materials Thickness Not Less Than 1 Mm Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside With 5 Compartments. Shelve Size 908 X 430 Mm Crca Steel: Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.0 Mm Range As Per Is-513 1994 ( Reaffirmed In1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. Hot Rolled Steel Used For Thickness 2.0 To 3.15 Mm Range As Per Is-1079 1994 Is-1079 1994 ‘D’ Quality Or Is-10748 1995 Grade-Ii. Chemical Composition, Tensile Properties, Bend Test, Surface Flaws, Roll Mark, Dent & Lines Etc. Weight 80 Kgs Finished General Condition With 3 Years Warranty Finish As Per General Condition Of Tender 100 Chairs For Office 1. Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 ±0.1Cm. Thick Hot-Pressed Plywood Measured And Upholstered With Fabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area. The Chair Is Available In Three Models. Mid Back Size 47.5 Cm. ( W ) X 58.0 Cm. ( H ) *Pch-9U01rg / 9U02rg / 9U12rg Seat Size 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2. High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density = 45±2 Kg / M3 And Hardness Load 16 ± 2 Kgf As Per Is:7888 For 25% Compression. 3. Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4. Center Tilt Synchro Mechanism ( For 9U01rg / 9U02rg ) : The Mechanism Is Designed With The Following Features: · 360° Revolving Type. · 3 Position Locking · Tilt Tension Adjustment 5. Tubular Frame ( For 9U12rg ) : The Powder Coated ( Dft 40-60 Microns ) Tubular Frame Is Cantilever Type & Made Of Ø 2.54 ±0.03Cm. X 0.2 ±0.016Cm.Thk. M.S. Er.W. Tube. 6. Pneumatic Height Adjustment ( For 9U01rg / 9U02rg ) : The Pneumatic Height Adjustment Has An Adjustment Stroke Of 12.0 ±0.3Cm. 7. Telescopic Bellow Assembly ( For 9U01rg / 9U02rg ) : The Bellow Is 3-Piece Telescopic Type And Injection Moulded In Black Polypropylene. 8. Pedestal Assembly ( For 9U01rg / 9U02rg ) : The Pedestal Is Injection Moulded In Black 33%Glass-Filled Nylon And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Is 66.3 ±0.5Cm. Pitch-Centre Dia. ( 76.3 ±1.0Cm With Castors ) . 9. Twin Wheel Castors ( For 9U01rg / 9U02rg ) : The Twin Wheel Castors Are Injection Moulded In Black Nylon. Overall Dimensions Of Chair Width ( W ) : 76.3 Cm. Depth ( D ) : 76.3 Cm. Height ( H ) : 85.5-97.5 Cm. Seat Height ( Sh ) : 42.5-54.5 Cm Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 50 Teachers Classroom Table Lecture Table Size: 1500 L X 600 D X 750 Ht System: Angular Legs Specification: Table Top: 25Mm Thick Pre-Laminated Particle Board Finished With 2Mm Pvc Edge Banding On All Exposed Edges. Under Structure: Ms Powder Coated Switch Angular 40X40 Legs And Ms Powder Coated Cross Beams ( 40X20 ) Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge.. 250 Examination Hall Table 1 Dimensions: 750 Mm X 450 Mm X 750 H Mm 2 Material : 2.1 A ) Plb / Plt – Top 2.2 Impregnated Base 18Mm Thickness With 2Mm Thick Hot Pressed Pvc Beading 2.3 C ) Under Structure : This Table Comes With A Square Tube Under Structure With Prime Quality C.R Tube Steel. 3 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601-1984, Is- 7138-1973, Is-4923-1985. 4 Top Frame And Legs :30 X 30 C.R Square Tube 1.2Mm Thickness With One Foot Steps. 5 These Shall Be Manufactured From Pvc Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm With 3 Years Warranty Finish As Per General Condition Of Tender 120 Lecture Hall Dual Desk Bench For ( 2 ) Students Genii 2Strfr+Rr Plt Choco Sm6 1240 X 1130 X 757 Desk-Top Panel-All Panels Are Made From 18Mm Thk Pre-Laminated Twin Board ( E1 / P2 Grade ) With Pvc Edge Banding On All Sides.The Panels Have Cornersrounded For Safety Usage. Understructure - All Side Metal Frames And Cross Connectors Are Made From Combination Of 25.4 X1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes , 31.8 X 1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes And 28.6 X 1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes ( As Per Is:7138 ) Which Are Welded Together.The Welded Structures And Cross Connectors Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.Back Supports Which Are Provided At The Rear Back Are Made Of 50.8 X 25.4 X 1.2 Mm Thk ( Approx. 18 Swg ) Rectangular Erw Tubes ( As Per Is:7138 ) .The Tubes Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.The Storage Shelves Are Made From 0.6 Mm Thk Ms Sheet ( As Per Is:513 ) Fixed Below The Radesk Top Panel And Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating. Hooks Are Provided On The Vertical Side Frames On Both Sides Of The Desk For Hanging Bags / Bottles. They Are Made From 2 Mm Thk Ms Sheet ( As Per Is:513 ) And Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.The Understructure Is Assembled Using M6 Trilobular Screws ( As Per Din 7500 ) With Zn Blue Plating.Compact Laminate Seat And Back Panels Are Assembled Using M6 Counter Sunk Trilobular Screws ( As Per Din 7500 ) With Zn Black Plating ( As Per Is 1573:1986 ) Spacers Are Provided On Th Top Of Round Tubes For Wooden Panels Fixing. They Are Made Of Made Glass Filled ( 30% ) Plastic Caps Made Of Pp Copolymer ( 3530 Grade ) Are Also Provided On The Rear Frames Adding More Aestheic Value To The Product.M6 High Tensile Tvs Make Bolt ( Class 8.8 ) With Glasss Filled Nylon Level Adjustors Are Provided At The Bottom Of Understructure To Take Care Of Unevenness In Floor With Height Adjustment Of Approx 15Mm Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge.. 25 Table ( Office Table Big Size ) 1 Dimensions:1450 W X 680 D X 750 H ( In Millimetres ) 2 Material: 2.1 A.Plb / Plt - Top 25 Mm Thickness. 3 All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 4 Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 5 Each Plb / Plt May Contain Following Material Layers: 6 Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 7 C. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Square Tube 1.22Mm Thickness. 8 D. Storage: 3 Draw & 2 Draw Metal Is Provided For Storage. One Side 2 Draw And Other Side 3 Draw Metal Shall Be Provided. 9 Drawer: • Box-Box-File : Dimensions 390 W X 430 H X 560 D Mm, Construction & Material:Welded Assembled, Crca As Per Is-513.• Back , Sides, Top & Bottom , Box 0.6 Think. Drawer Tray & Front- 0.8 Mm. Crca As Per Is-513 , Drawer Slides Used Must Be Of Heavy Duty Telescopic Channels 10 All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 11 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 12 Shoes - These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 500 Student Study Table 1 Study Table Of Size 1200 Mm X 600Mm X 750Mm Having Wood Laminate Finish The Table Top / Work Surface: Made From 25Mm Thick Plb With Pvc Lipping. Side Panels: Made From 18Mm Thick Plt With Pvc Lipping. Modesty Panel: Made From 18Mm Thick Plt With Pvc Lipping. Neat Wiring Flow With Cut-Outs On Both Sides, Free Standing Pedestal For Adequate Personal Storage. 2 Material: 3 A.Plb / Plt - Top 25 Mm Thickness. 4 All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 5 Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 6 Each Plb / Plt May Contain Following Material Layers: 7 Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 8 C. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Squre Tube 1.22Mm Thickness. 9 D. Storage: Single Drawer Is Provided For Storage With Right Side With Metal Shall Be Provided. 10 Drawer: • Box-Box-File : 550 X 420 X 390, Construction &Material:Welded Assembled, Crca As Per Is-513.• Back , Sides, Top & Bottom , Box 0.6 Thick. Drawer Tray & Front- 0.8 Mm. Crca As Per Is-513 , Drawer Slides Used Must Be Of Heavy Duty Telescopic Channels 11 All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 12 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 13 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. 14 Finish As Per General Condition Of Tender With 3 Years Warranty Finish As Per General Condition Of Tender 60 3 Seater Visitor Chair Supply Of Orbit 3 Seater Visitors Chair, *Cushioned Seat And Back *Silver Grey Finish With Arms Model No. Sj-708La Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Almarah Steel Full Size Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding &Ark Welding. Anticorrosion Treated Components. Dimensions Outer: 1980 H X 910 W X 480 D Mm Main Door With Shetters Top, Bottom Lh & Rh Sides, Shelves And Back All Materials Thickness Not Less Than 1 Mm Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside With 5 Compartments. Shelve Size 908 X 420 Mm Crca Steel: Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.0 Mm Range As Per Is-513 1994 ( Reaffirmed In1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Open Rack 1 Steel Slotted Angular Racks, Open Type With 6 Shelves Making 5 Compartments Of Size 1800Mm X 900Mm X 450 Mm, Cr Sheet Shelfs 1.2Mm Thickness With An Angle Of 2 Mm Thickness And Size: 40 Mm X 60 Mm, With 8 Corner Brackets Of 2 Mm Thickness. 2 Finish: Sheet Metal Components: All Dents, Burrs And Sharp Edges Shall Be Removed From The Various Components. The Components Shall Be Individually Pickled, Scrubbed And Rinsed To Remove Grease, Rust, Scale Or Any Other Foreign Element. Immediately After Pickling, All The Mild Steel Parts Shall Be Given Phosphate Treatment Conforming To Class C Or Is : 3618-1966. 3 The Process For Application Of Phosphate Coating Shall Be In Accordance With Is: 6005-12970. Two Coats To Enamel Paint ( Colour Grey Is Preferred ) Shall Then Be Applied As Follows: Finish Coat With Enamel Paint Conforming To Is : 151-1950, Is : 2932-1974 Or Is : 2933-1975. In The Case Of Stoving Enamel The Components Shall Thereafter Be Backed At A Specified Temperature In An Over Heated Uniformly. The Finish Shall Be Smooth And Uniform With A Hard And Touch Film Of Enamel, Strongly Adhering To The Surface. The Finish Shall Be Free From All Visible Defects And Shall Not Chip When Tapped Lightly With A Dull Pointed Instrument. Note: Putty Shall Be Applied To All The Surfaces Requiring Filling And Shall Conform To Is: 110-1968. 4 Tests: The Performance Tests Required For The Finished Racks Shall Be Carried Out As Per The Methodology Mentioned In The Is 6189:1985. The Rack Shall Have A Name Plate Or Label Fixed To It Showing The Manufacturer’S Name, Initials Or Recognized Trademark. 5 Hospital Furniture Items Shall Be Subjected To Tests In Accordance With The Requirements Of Relevant Specifications. However, The Painted Furniture Items Shall Also Satisfy The Adhesion Test And In Addition Satisfy The Performance Test Give Below: 6 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 25 Dining Table With Benches Supply Of Dining Table, Specification: Size 93 L X 30W X 30H With 8 Seater, Top In 18 Gauge Of 304 Grade Stainless Atell , Legs In 1 1 / 2 X 1 1 / 2 Square Tube Stainless Stell In 16 Gauge Of 304 Grade With Foldable Benches As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 25 Library Table Size: 1800 X 900X 750 Mm The Understructure Should Be Available In Cr Square Tube. It Should Be Fixed And Shall Accommodate 6 People The Table Top Should Be 25 Mm Thick Pre Laminated Particle Board With Teak Wood Beading 40 Mm Thickness With Polish Top Frame And Legs Crs Quare Pipe 40X40 Mm, 1.6 Mm Thickness With 6 Legs Two Support Footrust With 35 H X 3Mm Pvc Bush. With 3 Years Warranty Finish As Per General Condition Of Tender 5 Principal Table Supply Of Cabin Table, Main Table Of Size 2400 L X 900 D X 750 Ht, Side Composite Storage Unit Size 1350 L X 450 D X 750 Ht, System - Enrich Series. Specifications: Table Top: 25Mm Thick Pre-Laminated Particle Board With 2Mm Pvc Edge Lipping On All Exposed Edges. Under Structure: Supported On Chrome Plated Enrich Legs Supporting On Ms Powder Coated Cross Beams ( 40X20 ) . Modesty Panel: 18Mm Thick Plt Modesty Panel Of 450Mm Ht. Wire Management: Anodised Finish 350 X 150 Flip Up Box With Soft Closures, Without Sockets And Switches Are Provided, Pvc Cable Dump & Vertical Wire Entry Cover For Wire Uptake From Floor To Cable Tray. Storage Unit Top - 25Mm Thick Pre Laminated Particle Board With 2Mm Pvc Edge Lipping. Body, Shelfs & Shutters – 18Mm Thick Pre Laminate Particle Board With 2Mm Pvc Edge Lipping. Back – 9Mm Thick Pre Laminate Particle Board With 2Mm Pvc Edge Lipping. Lock - Regular Lock. Handle - Finger Grooves Hardware – Door Closing Hinges, Mini-Fix, Levellers & Locks, Etc., Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 5 Executive Chair For Principal Pulse Hb Mb Seat, Adj. Arms Larger Seats Head Rest 1.Seat / Back Assembly: The Seat Is Made Up Of 1.5 ± 0.1Cm Thk. Hot Pressed Plywood Measured. The Back Is Made Up Of Injection Moulded Glass Filled Polypropylene & Upholstered Using Net Fabric With High Tenacity Yarn. *Seat Size ( Larger Seat Depth ) { Pulsal } : 47.0 Cm. ( W ) X 51.5 Cm. ( D ) *Back Size ( Pulsax, Pulsal ) : 45.0 Cm. ( W ) X 65.3 Cm. ( H ) 2.High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density =55+ / -2 Kg / M3 And Hardness 16 ± 2 Kgf As Per Is:7888 For 25% Compression. 3.Armrests ( Adjustable ) { Pulsax, Pulsal } : The Adjustable Armrest Is Designed With The Following Features: •Up-Down Adjustment- 6 Steps ( 7.2 ± 0.5Cm Range ) •Armrest Top Is Mounted On Armrest Structure Made Of Glass Filled Nylon. •Armrest Top Is Pu Moulded Over Glass Filled Nylon Insert. 4.Lumbar Support Assembly: The Lumbar Support Consists Of Polypropylene Pad.The Height Of Lumbar Pad Can Be Adjusted Through Two Projecting Knobs Provided On The Rear Side Of The Pad. Lumbar Pad Has An Adjustment Of 8.0 ± 0.5 Cm In Height. 5.Front Pivot Synchro Mechanism: The Adjustable Tilting Mechanism Is Designed With The Following Features. •360° Revolving Type. •Single Point Control. •Front-Pivot For Tilt With Feet Resting On Ground Ensuring More Comfort. •Tilt Tension Adjustment. •4-Position Locking With Anti-Shock Feature. •Seat / Back Tilting Ratio Of 1:2. 7.Pneumatic Height Adjustment: The Pneumatic Height Adjustment Has An Adjustment Stroke Of 10.0 ± 0.3 Cm. 8.Pedestal Assembly: The Pedestal Is Injection Moulded In Black 30% Glass-Filled Nylon And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Pitch-Center Dia Is 066.1 ± 0.5 Cm. ( 76.1 ± 1.0 Cm. With Castors ) . 9.Twin Wheel Castors: The Twin Wheel Castors Are Injection Moulded In Black Nylon. Overall Dimensions Of Chair Width ( W ) : 76.1 Cm Depth ( D ) : 76.1 Cm Height ( H ) : 98.0 - 108.0 Cm Seat Height ( Sh ) : 45.8 - 55.8 Cm. Neckrest : The Neckrest Assembly Consist Of Polypropylene Pad With Moulded Polyurethane Foam & Covered With Polyester Fabric Neckrest Is Fixed To Back Assembly Through Neckrest Connector Neckrest Assembly Has Height Adjustment Of4.2 + 0.5 Cm And Rotation Adjustment Of Overall76”+ 2”. The Complete Neckrest Assembly Is Retro Fit To The Main Chair Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 50 Alamarah With Acrylic ( Glass ) Door 1. Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding & Co2 Welded. Front Side Doors With Acrylic Transparent Sheet All Round Frame 70 Mm Borders Thickness 5.5 Mm Thickness 2. Dimensions Outer: 1980 H X 910 W X 480 D Mm 3. A. Top, Bottom, Lh & Rh Sides And Back Material Thickness- 1 Mm 4. B. Removable Rh & Lh Main Doors With Stiffeners Material Thickness =1.22 Mm 5. Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside Shelve Size Of 908 W X 420 D Of Thickness -1 Mm 6. Cr Steel: 7. Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.2 Mm Range As Per Is-513 1994 ( Reaffirmed In 1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. 8. Finish As Per General Condition Of Tender With 3 Years Warranty Finish As Per General Condition Of Tender 25 Office Table With Draws ( Office Table Small Size ) 1. Dimensions:1200 W X 600 D X 750 H Mm 2. Material: 2.1 A.Plb / Plt - Top 25 Mm Thickness. 3. All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 4. Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 5. Each Plb / Plt May Contain Following Material Layers: 6. Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 7. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Square Tube 1.22Mm Thickness. 8. D. Storage: 3 Draw Is Provided For Storage. With Right Side With Metal Shall Be Provided. 9. Body For Storage Units: Body And Draws For Storage Unit Dimensions 390 W X 430 H X 560 D Mm Shall Be Made From Cr Steel Sheet Not Less Than 0.8 Mm Thick With Heavy Duty Telescopic Channels. This Shall Be Bent To Box Shape From One Piece And Tack Welded At Final Overlapped Comer Or Assembled With A Maximum Of Two Pieces Properly Welded 10. All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 11. All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 12. Shoes - These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Office Chairs S Type With Armrest ( Nursing Station ) Supply Of Class Room Chair And Hostel Room Study Chair, Cushioned Seat & Plastic Back Without Arms & With Powdercoated Legs With Bushes, Magna Va - Plastic ( Pc ) Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 3 Examination Couch Examination Table On Ratchet With No Storage Overall Dimension Of L 1830Mm X W 600Mm X H 850 Mm. The Backrest Has Ratchet Mechanism For Tilting The Backrest. Leg Frames & Intermediate Frames Is Made Of Erw Tubes Having Section Of 30 X 30 Square Tubes With Thickness Of 1.6Mm. Nylon 6 Leg Shoes Is Given To Avoid Wear & Tear. Ms Sheet Metal Lying Surface Of Thickness 1.2Mm Is Used. Top Sheet Metal Panel Base Frame Of 25 X 25 Erw Square Tubes Of Thickness 1.6Mm Is Used. Ratchet Is Of Ms Strip With Section 40 X 4 To Provision The Backrest Tilt. All Ms Part Are Pre Treated And Powder Coated With Ral White Color & All Plastic Parts In Grey. Safe Working Load Is 135Kg Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 500 Student Chair With Pad Royal Visitor S Type Pad Chair Cushion Seat And Back Cushion Foam And Quality Moulded Ply With Pu Handles With 1 Hr Round Pipe 16 Gauge With Fabric With 18 Mm Pre-Laminated Writing Pad. All Hr Pipes Section Are Shall Be Pre-Treated And Epoxy Powder Coated 50-60 Microns Thickness With 3 Years Warranty Finish As Per General Condition Of Tender
Contract Date: Ref. Documents Contract Value : 1.31 Crore
Government Departments No of Bidders 1
25.
Housing Urban and Rular Development #11346479 Technical Bid
Tender for Construction Of Modular Ot Eye Under Old Sadar Hospital At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
26.
Housing Urban and Rular Development #11346477 Technical Bid
Tender for Construction Of Modular Ot (Eye) Under Sub Divisional Hospital At Madhupur Dist Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
27.
Housing Urban and Rular Development #11346476 Technical Bid
Tender for Construction Of Modular Ot (General & Gynae) At Chc Under Sarwan Block At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Multi Purpose Ot Table With C - Arm Compitable , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro-Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
28.
Defence #11345421 AOC
Bids Are invited for Procurement Of Ars Items Brown Sheet Laminated - Sai Browen Sheets For Notebooks Per Sheet Lxh 28 Inch Into 20 Inch , Broom Country - Brand Kgtoc Coconut Broom Stick For Floor Cleaning Type Wet And Drycolour Brown Brush Material Coconut Fibre Plastic Handle , Blue Laundry , Biodegradable Polythene Film Length 112 Inch Width 18 Thk 0 Point 007 Inch - Biodegradable Polythene Film I X H X Thk 112 Inch X 18 Inch X 0 Point 007 , Battery Aa 1 Point 5 V - Duracell Alkaline Aa Batteries Pack Of 10 , Bag Gunny , Antirust Spray - Pidilite Wd 40 Multipurpose Car Care Spray 420 Ml Rust Remover Lubricant Stain Remover Powerful Chimney Cleaner Degreaser And Bike Chain Cleaner And Chain Lube 341G , Air Freshner Air Pocket , Abrasive Paper 230 Mm Into 280 Mm , Abrasive Cleaning Pad Scrabber Pad - Cloth Brite Silver Sparks Scrub Pad 2 Point 75 Into 4 Brand Scothbrite Material Nylon Colour Green , Geru Red - Shree Ji Natual Gerumitti Geru Powder , Garbage Bag - Halimar Premium Oxo Biodegradable Gabage Bags 17 Into 19 Inches Small 180 Bags Dustbin Bags Trash Bag Black Color , Fiber Dust Brush - Brand Innayat Niks Tim Hawk Colour Multicolour Plastic Model Name Microfiber Extendable Rod Dusting Brush Mop For Cars Office Home Medium , Feather Broom Phool Jhadu - Scotch Brite No Dust Broom Long Handle Easy Floor Cleaning Multi Use , Envelope Size 6 Inch Into 12 Inch - Strotam Self Seal Green Cloth Lined Polynet Envelope 12 Inch Into 6 Inch , Envelope Size 4 Inch Into 10 Inch - Strotam Self Seal Green Cloth Lined Polynet Envelope 4 Inch Into 10 Inch , Envelope Size 10 Inch Into 14 Inch - Strotam Self Seal Green Cloth Lined Polynet Envelope 10 Inch Into 14 Inch , Envelope Cloth Coated Size 9 Inch Into 12 Inch - Strotam Self Seal Green Cloth Lined Polynet Envelope 9 Inch Into 12 Inch , Envelope Cloth Coated Size 12 Inch Into 16 Inch - Strotam Self Seal Green Cloth Lined Polynet Envelope 12 Inch Into 16 Inch , Envelope Cloth Coated Size 10 Inch Into 14 Inch - Strotam Self Seal Green Cloth Lined Polynet Envelope 10 Inch Into 14 Inch , Mosquito Repellent Machine With Liquid - All Out Ultra Mosquito Repellant Starter Pack Of 1 , Mosquito Repellent Gel Odomos - Odomos Non Sticky Mosquito Repellent Cream With Vitamin E And Almond 100 Gram Pack Of 1 , Microfiber Cloth , M Seal - M Seal Epoxy Putty 500 Gram Per Packet , Lime Slaked 56 Lbs - Lotus Lime Chuna Powder 25 Kgs Per Packets Lime Stone Powder Quicklime White Wash Powder , Jerry Cans 20 Ltrs - V Metal Arts Plastic Jerry Can Oil Fluid Tank For Generators Jeeps Marine Activities Boat And Other Vehicles 20 Litre , Hand Wash Liquid - Savlon Professional Germ Protection Liquid Hand Wash Refil Can , Hand Towel - Heelium Bamboo Hand Towel 65 Into 40 Cm Super Soft And Quick Absorbent And 600 Gsm , Hand Sanitizer , Glass Cleaner 500 Ml - Colin Glass And Surface Cleaner Liquid Spray 500 Ml , Cotton Rags - Usage Cleaning And Wiping Packaging Type Sack Size 12 Inch Into 12 Brand Unique Pack 20 Kgmaterial Cotton , Cloth Stocknite Mutton Cloth - Spiffysky Tubular Bandage Stockinette Roll Color White 4 Inch Into 20 Mtrs Brand Spiffy Sky Generic Material Cotton , Cloth Sponge - Dhwani Enterprise Cotton Duster Cloth With 1 Check Duster Cloth Free Pack Of 6 , Cleaning Liquid For Utensils - Vim Dish Wash Liquid Gel Lemon With Lemon Fragrance Leaves No Residue Grease Cleaner For All Utensils 500 Ml Bottle , Cleaning Bar For Utensils 500 Gms - Vim Dish Wash Bar Lemon Tub With Power Of 100 Lemon Fastest On Burnt Food Stains Comes With A Sturdy Re Usable Box And Free Scrubber 500 G , Cleaning White Toilet Harpic - Harpic Power Plus Original Toilet Cleaner Bottle Of 200 500 Ml , Can Plastic 10 Ltrs - Capacity 10 Litre Color White Usage Chemical Brand Bhagwatiplas Material Hdpe , Candle Wax - Wax Candles Wax 3 Into 4 Inches Ivory 5 Hour Battery Life Flickering Led Flame Unscented , Brush With Long Handle - Brand Hic Hamara India Clean Color Multi Colour Handle Material Stainless Steel Bristle Type Unflagged Bristle , Brush Sweeping Handle - Wooden Cleaning Brush Wood And Plastic Green And Light Brown Color Versatile Total Quantity : 5141
Contract Date: Ref. Documents Contract Value : 1.37 Lakh
Government Departments No of Bidders 11
29.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
30.
Public Administrative Department #11334085 Price Bid
Tender for Annual Plan-Tholicode Gp-64/2025-26: -Panacode Maintenance Of Gramakendram-General Civil Work-1 MAINTENANCE OF PANAKKODU GRAMAKENDRAM1.001 15.28.1:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet1.002 15.17.1:Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:R.S. Joists1.003 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar1.004 15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below1.005 15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.1.006 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete1.007 OD377884/2025-2026: Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.1.008 OD377883/2025-2026:Supplying and fixing 150mm dia PVC rain water gutter SQUARE section including fitting with 32mx5m MS flat supporters at 1m interval etc. complete1.009 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)1.01 13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster1.011 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete1.012 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)1.013 21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) 1.014 21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides1.015 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil1.016 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
31.
Defence #11329346 AOC
Bid Are Invited For Acrylic Distemper, Make Asian,Berger, Dulux Or Equivalent. , White Cement, Birla Wall Care,Jk White,Berger,Asian Paints Or Equivalent Make , Melamine Solvent,Thinner, Approved Make , Wall Putty , Birla Wall Care,Jk White,Berger,Asian Paints Or Equivalent Make , Aggregate Stone 20Mm , Bricks, 75 No,1St Class , Coarse Sand Crusher , Aluminium Door Handle 4 Inch, Classic Or Equivalent Make , Brass Ferrul 15Mm, Standard Quality , Brass Ferrul 20Mm, Standard Quality , Brass Ferrul 25Mm, Standard Quality , Brass Spindle 15Mm Half Round, Standard Quality , Brass Shower Concealed Spindle 15Mm, Standard Quality , Cp Brass Toilet Paper Holder, Prayag,Supreme,Cera,Hindware,Parryware,Jaquar Or Equivalent Make , Cp Brass Single Lever Telephonic Wall Mixer, Prayag,Supreme,Cera,Hindware,Parryware,Jaquar Make , Cp Brass Extension Nipple 15X25Mm, ,Cera,Hindware,Parryware,Jaquar, Make , Cp Brass Extension Nipple 15X40Mm, ,Cera,Hindware,Parryware,Jaquar, Make , Cp Brass Grating 4 Inch Jali 50 Round And 50 Square , Cpvc Pipe 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Or Equivalent Make , Cpvc Pipe 25Mm Dia, Prayag,Prince,Supreme,Ashirwad Or Equivalent Make , Cpvc Pipe 32Mm, Prayag,Prince,Supreme,Ashirwad Or Equivalent Make , Belmonte 8.25 Inch,Cm Dual Flush Siphone ,Single,One Piece Western Commode,Toilet,Ewc Repair Kit, Hindware, Cera, Sommany Or Equivalent , Gi Union 40Mm , Unik,Jindal Or Equivalent Make , Gi Elbow 15Mm Dia, Make Unik, Jindal Or Equivalent , Gi Elbow 20Mm Dia, Make Unik, Jindal Or Equivalent , Gi Nipple 15X100Mm, Standard Quality , Gi Nipple 15X150Mm, Standard Quality , Gi Nipple 15X50Mm, Standard Quality , Gi Nipple 15X75Mm, Standard Quality , Gi Nipple 20X100Mm, Standard Quality , Gi Nipple 20X150Mm, Standard Quality , Gi Nipple 20X50Mm, Standard Quality , Gi Nipple 20X75Mm, Standard Quality , Gi Nipple 25X150Mm, Standard Quality , Gi Nipple 25X50Mm, Standard Quality , Gi Nipple 32X50Mm, Standard Quality , Gi Nipple 40X100Mm, Standard Quality , Gi Nipple 40X150Mm, Standard Quality , Gi Nipple 40X50Mm, Standard Quality , Gi Nipple 40X75Mm, Standard Quality , Gi Nipple 50X100Mm, Standard Quality , Gi Nipple 50X150Mm, Standard Quality , Gi Nipple 50X50Mm, Standard Quality , Gi Nipple 50X75Mm, Standard Quality , Gi Plug 32Mm, Standard Quality , Gi Plug 50Mm, Standard Quality , Gi R-Elbow 25X40Mm, Standard Quality , Gi R-Socket 25X40Mm, Standard Quality , Gi Rsocket 32X40Mm, Standard Quality , Gi R-Socket 50X40Mm, Standard Quality , Gi Socket 15Mm, Standard Quality , Gi Socket 20Mm, Standard Quality , Gi Socket 32Mm, Standard Quality , Gi Tee 15Mm Dia, Standard Quality , Glass 4Mm Thick Plain, Unik,Jindal Or Equivalent Make , Glass 5.50Mm Thick Plain, Saint Gobin,Modi Guard Or Equivalent Make , Glass Putty In Bag 10 Kg , Standard Quality , Frosted Glass 5.5Mm Thck, Approved Make , Cupboard Door Knobs, Standard Quality , S.S Curtain Rod Wall ,Concealed Socket 25Mm Dia, Standard Quality , Ptmt - Waste Coupling 31,32 Mm , Paryag,Prince,Supreme,Ashirwad Or Equivalent Make , Ptmt Ball Cock With Rod And Ball 15Mm Compelte With Epoxy Coated Aluminm Rod And H.D, Paryag,Prince,Supreme,Ashirwad Or Equivalents Make , Ptmt Ball Cock With Rod And Ball 20Mm Compelte With Epoxy Coated Aluminm Rod And H.D Ball, Prayag,Prince,Supreme,Ashirwad Or Equivalent Make , Ptmt Grating Round Jali 125Mm Dia With ,Without Hole Paryag,Prince,Supreme,Ashirwad Or Equivalent Make , Pvc Bend,Elbow 75 Mm Dia, Finolax,Supreme,Plasto Or Equivalent Make , Ptmt Jet Spray With 1.5M Tube Prayag,Prince,Supreme,Ashirwad Make , Pvc Flush Pipe Long Bend With Fitting For Indian Toilet Seat, Paryag,Supreme,Ashirwad Make Or Equivalent , Pvc Flush Pipe Short Bend With Fitting For European Toilet Seat Standard Quality , Pvc Socket 75 Mm Dia, Paryag,Supreme,Ashirwad Make Or Equivalent , Pvc Syphon For Low Level Cistern, Paryag,Supreme,Ashirwad Make Or Equivalent , S.S Connection Pipe 450Mm For Geyser Hot Water , Special Rubber And Pvc Plastic Door Back Rubber, Standard Quality , Pvc Connection Pipe 600Mm Long With Union, Prayag,Prince,Supreme,Ashirwad Make Or Equivalent , S.S Connection Pipe For Basin Mixer Standard Quality , S.S Curtain Rod Wall Stand Bracket,Holder Suitable For 25Mm Dia Pipe, Standard Quality , Paving Bitumen Of Grade Vg-10 Of Approved Quality , Orissa Pattern W.C. Pan 580X440 Mm, ,Cera,Hindware,Parryware,Jaquar, Or Equivalent Make , White Plastic Seat Solid With Lid C.P. Brass Hinges And Rubber Buffers, ,Cera,Hindware,Parryware,Jaquar,Kingstone Or Equivalent Make , G.I. Pipes 15 Mm Dia, Jindal, Surya, Tata Or Equivalent Make , G.I. Pipes 20 Mm Dia, Jindal, Surya, Tata Or Equivalent Make , G.I. Pipes 25 Mm Dia, Jindal, Surya, Tata Or Equivalent Make , G.I. Pipes 50 Mm Dia, Jindal, Surya, Tata Or Equivalent Make , Rectangular Shape 600X450 Mm Precast R.C.C. Manhole Cover With Frame - L.D. - 2.5 Each, Make Dalal, K.K., Sushma Enterprises , C.I. Cover And Frame 300X300 Mm Inside Approved Make , C.I. Cover Without Frame 300X300 Mm Inside Weight Not Less Than 4.50Kg, Approved Make , Ci Detachable Joint 250Mm, Standard Quality , Stainless Steel Kitchen Sink - With Drain Board 510X1040 Mm Bowl Depth 178 Mm, Make Jindal, Nirali Or Equivalent , Stainless Steel Kitchen Sink - Without Drain Board 610X460 Mm Bowl Depth 200 Mm, Make Jindal, Nirali Or Equivalent , Cpvc Ball Valve 32Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Brass Threaded Elbow 15X15Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Brass Threaded Elbow 15X20Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Elbow 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Elbow 25Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Elbow 32Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Fta 32Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Male Adapter Brass Threads 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Male Adapter Brass Threads 25Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Mta 20X15Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Mta 32Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Pipe Clamp 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Pipe Clamp 25Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Socket 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Socket 25Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Socket 32Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Solvent 100 Ml Pack , Astral Or Equivalent , Cpvc Tank Nipple 32Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Tee 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Tee 25Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Tee 32Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Union 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Union 25Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc R-Coupling 20X15Mm, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Tank Conector 20Mm Dia, Prayag,Prince,Supreme,Ashirwad Make , Cpvc Tank Conector 25Mm, Prayag,Prince,Supreme,Ashirwad Make , Brass Ball Valve Screed 15Mm Dia, Zoloto Kirloskar Or Equivalent Make , Brass Ball Valve Screed 25Mm Dia, Zoloto Kirloskar Or Equivalent Make , Brass Ball Valve Screed 32Mm Dia, Zoloto Kirloskar Or Equivalent Make , Brass Ball Valve Screed 50Mm Dia, Zoloto Kirloskar Or Equivalent Make , Gm Gate Valve 32Mm, Zoloto Kirloskar Or Equivalent Make , Lead Wool, Standard Quality , M-Seal , Cutter Blade 4Inch For Tiles And Marble, Standard Quality , Cutter Blade 5Inch For Wooden And Plyboard, Standard Quality , Nails 1.5Inch, Standard Quality , Nails 4 Inch, Standard Quality , Soot Gola Pack Of 20 Gola , Standard Quality , Stainless Steel Welding Rod Size 3.15X350Mm Pack Of 2Kg , Mangalam Or Equivalent , Stainless Steel Wire Mesh, Standard Quality , Hot Water Connection Pipe 600Mm Long Make Paryag Or Equivalent , Toughened Glass Door Lock Make Godrej Or Equivalent , 18Mm Plywood Size Of 8 Feetx4 Feet With Termite Proof And Water Resistance Make Century Or Sainik , 6Mm Plywood Size Of 8 Feetx4 Feet With Termite Proof And Water Resistance
Contract Date: Ref. Documents Contract Value : 16.86 Lakh
Government Departments No of Bidders 4
32.
Public Administrative Department #11325415 AOC
Tender For Maintenance Of Municipality Abcd Blocks-General Civil Work; 1 MUNICIPAL OFFICE A&B BLOCK 2 OD429488/2023-2024:Labour engaged for cleaning surrounding area 3 OD429932/2023-2024:Cleaning the tiled surface and removing dirt, dust , bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agentEngineer - incharge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building / structure, all as per direction of Engineer- in- Charge ( The rate is inclusive of all materials & labours involved except scaffolding). 4 14.76:Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. 5 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 6 50.18.9.11.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 15 mm dia 10 Kgf/cm2- External work - Exposed on wall 7 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 8 9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. 9 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 10 21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 11 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 12 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 13 OD334510/2025-2026:200mm wide uPVC square rain water gutter,UPVC qutter clamp,UPVC end cap,joints etc 14 OD334511/2025-2026:Providing and fixing steel bib cock of approved quantity conforming to IS: 8931 15 OD334512/2025-2026:Supplying and fixing 75mm dia PVC pipe for the down water (4kg/cm2) 16 OD334513/2025-2026: Providing and fixing factory made PVC door including cost of all fittings, labour charges etc complete (Approved Data of CE LSGD vide circular dated 18.08.2016) OD-11,DSR 2016 1.4902 dtd 05.06.2017 17 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 18 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 19 50.9.11.2:Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately)as per the direction of site Engineer-in-charge. Please Enable Macros to View BoQ information
Contract Date: Jun 22, 2026 Contract Value : 4.23 Lakh
Government Departments No of Bidders 1
33.
Public Administrative Department #11325176 AOC
Tender For Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Achitrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: (Dsr No. 15.12) , Of Area 3 Sq. Metres And Below (Dsr No. 15.12.1) , Dismantling Of Flushing Cistern Of All Types (C.I./Pvc/Vitrious China) Including Stacking Of Useful Materials Near The Site And Disposal Of Unsericeable Materials Within 50 Metres Lead. (Dsr No. 15.52) , Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials Including Malba All Complete As Per Directions Of Engineer-In-Charge. (Dsr No. 14.82) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. (Dsr No. 15.56) , 6 Mm Cement Plaster 1:3 (1 Cement : 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Reinforced Cement Concrete Slabs And Beams. (Dsr No. 13.17) , Disposal Of Buidling Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. (Dsr No. 15.60) , Dismantling G.I. Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually/ By Mechanical Means Including Stacking Of Pipes Within 50 Metres Lead As Per Direction Of Engineer-In-Charge: (Dsr No. 15.44) , 15 Mm To 40 Mm Nominal Bore (Dsr No. 15.44.1) , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (Dsr No. 15.25) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window, Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Tuch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels (Dsr No. 8.2) , Granite Stone Slab Of Colour Black, Cherry/Ruby Red (Dsr No. 8.2.2) , Area Of Slab Over 0.50 Sqm (Dsr No. 8.2.2.2) , Regarding Terracing Of Md Phaska Covered With Tiles Or Brick, In Cement Mortar By Dismantling Tiles Or Bricks, Removing Mud Plaster, Preparing The Surface Of Mud Phaska To Proper Slope, Relaying Mud Plaster Gobri Leaping And Tiles Or Bricks, Grouted In Cement Mortar 1:3 (1 Cement : 3 Fine Sand), Including Replacing Unserviceable Tiles Or Bricks With New Ones And Disposal Of Unseviceable Material To The Dumping Ground (The Cost Of The New Tiles Or Brick Excluded), All Complete As Per Direction Of Engineer-In-Charge (Dsr No. 14.13) , 12 Mm Cement Plaster Of Mix: (Dsr No. 13.1) , 1:4 (1 Cement: 4 Fine Sand) (Dsr No. 13.1.1) , Painting Top Of Roofs Wih Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregnated With A Coat Of Coarse Sand At 60 Cudm Per 10 Sqm, Including Cleaning The Slab Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil Complete: (Dsr No. 12.15) , With Residual Type Petroleum Bitumen Of Grade Vg- 10 (Dsr No. 12.15.1) , Flush Pointing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement For Flat Tile Bricks On Top Of Mud Phaska (Dsr No. 14.18) , With F.P.S. Brick Tiles (Dsr No. 14.18.1) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10 Mm And Down Gauge), Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : (Dsr No. 12.21) , In 75X75 Mm Deep Chase (Dsr No. 12.21.1) , Making Khurras 45X45 With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1 M X 1M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. (Dsr No. 12.22) , Providing And Fixing Pvc Door Frame Of Size 50X47 Mm With A Wall Thickness Of 5 Mm (± 0.2 Mm), Made Out Of Single Piece Extruded Pvc Profile, With Mitred Cut Joints And Joint With 2 Nos. Of Pvc Bracket Of Size 190 Mm X 100 Mm Long Arms Of Cross Section Size 35 X 15 Mm & Self Driven Self Self Taping Screws, The Vertical Door Profiles To Be Reinforced With 40X20 Mm M.S. Rectangular Tube Of 0.8 Mm, Including Providing Epdm Rubber Gasket Weather Seal Throughout The Frame, Including Jointing 5 Mm Pvc Frame Strip With Pvc Solvent Cement On The Back Of The Profile. The Door Frame To Be Fixed To The Wall Using 8 X 100 Mm Long Anchor Fasteners Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. (Dsr No. 9.141) , 35 Mm Thick Factory Made Solid Panel Pvc Door Shutter, Made Out Of Single Piece Extruded Solid Pvc Profiles, 5 Mm (± 0.2 Mm) Thick, Having Styles & Rails (Except Lock Rail) Of Size 95 Mm X 35 Mm X 5 Mm, Out Of Which 75 Mm Shall Be Tapered (On Both Side), Having One Side Thickness Of 15 Mm Integrally Extruded On The Hinge Side Of The Profile For Better Screw Holding Power, Including Reinforcing With Ms Tube Of Size 40 Mm X 20 Mm X 1 Mm, Joints Of Styles & Rails To Be Mitered Cut & Joint With The Help Of Pvc Solvent Cement, Self Driven Self Tapping Screws & M.S. Rectangular Pipes Bracket Of Size 190 Mm X 100 Mm Of Cross Section Size 35 Mm X 17 Mm X 1 Mm At Each Comer, Single Piece Extruded 5 Mm Thick Solid Pvc Lock Rail Of Size 115 Mm X 35 Mm, Out Of Which 75 Mm To Be Flat And 20 Mm To Be Tapered At Both Ends, Having 15 Mm Solid Core In Middle Of Rail Section Integrally Extruded, Fixing The Styles & Rails With Thehelp Of Solvent And Self Driven Self Tapping Screws Of 125 Mm X 11 Mm, Including Providing 5 Mm Isngle Piece Solid Pvc Extruded Sheet Inserted In The Door As Panel, All Complete As Per Manufacturers Specialization And Direction Of Engineer-In-Charge (Dsr No. 9.142) , Decorative Finish (Wood Grained Finish) (Dsr No. 9.142.2) , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Making Food The Walls Etc. Concealed Pipe, Including Painting With Anti Coorosive Bitumasic Paint, Cutting Chases And Making Good The Wall : (Dsr No. 18.11) , 20 Mm Dia Nominal Bore (Dsr No. 18.11.2) , Providing And Placing On Terrace (At All Floor Levels) Polythylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. (Dsr No. 18.48) , Providing And Fixing Ist Quality Ceramic Glazed Wall Tile Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Coloures, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Enigneer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cment : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Includign Pointing In White Cement Mixed With Pigment Of Matching Shade Complete (Dsr No. 8.31) , Providing And Laying Polished Granite Stone Flooring In Required Desing And Patterns, In Linear As Well As Curvilinear Portions Of The Building Al Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing, And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge (Dsr No. 11.56) , Polished Grantie Stone Slab Of Colour Black, Cherry/Ruby Red Or Equivalent (Dsr No. 11.56.1) , Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete (Dsr No. 13.88) , Distempering With Ist Quality Acrylic Distemper (Ready Mixed) Having Voc (Volatile Organic Compound) Contents Less Than 50 Gram/Litre, Of Approved Brand And Manufacturer Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour (Dsr No. 13.81) , Old Work (One Or More Coats) (Dsr No. 13.81.1) , Finishing Walls With Textured Exterior Paint Of Required Shade: (Dsr No. 13.111) , Old Work (One Or More Coat Applied @ 1.67 Ltr/ 10 Sqm) On Existing Cement Paint Surface (Dsr No. 13.111.1) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100 Mm Sand Cast Iron P Or S Trap, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: (Dsr No. 17.1) , White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests (Dsr No. 17.1.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, Including Flush Pipe, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: (Dsr No. 17.2) , W.C. Pan With Isi Marked White Solid Plastic Seat And Lid (Dsr No. 17.2.1) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380X350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Wherever Required: (Dsr No. 17.5) , Single Half Stall Urinal With 5 Litre P.V.C. Automatic Flushing Cistern (Dsr No. 17.5.1) , Providing And Fixing Urinal Partition 10Mm Thick High Stainless Steel Of Siz 1.5 X 2.75 Fixed In Position With Clams Holding The Steel Partition. All Exposed Edges To Be Grinded With Smooth Finish To The Entire Satisfaction Of Engineer-In-Charge Including Carriage Of Material To Site Of Work, To The Entire Satisfaction Of Engineer-In-Charge Including Carriage Of Material To Site Of Work (Fixed On Slopping Back Wall Before Fixing Ceramic Tiles) (Nsi) , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: (Dsr No. 17.7) , White Vitreous China Flat Back Was Basin Size 550X400 Mm With Single 15Mm C.P. Brass Pilar Tap (Dsr No. 17.7.4) , Extra Over And Above Item No. 17.7.4 Of Dsr (Sr. No. 29) For Using Under Counter Washbasin Of Size 550 X 445 X 190 Mm As Per Archtechural Drawings, Code X0494 Or Parryware (Niagara) Model With Auto Closing Piller Cock System Code G 2013A 1 Of Parry Ware (Lapis Neo) With Adustable Brackets (Special For Under Counter) To Entire Satisfaction Of Engineer-In-Charge. (Nsi) , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. (Dsr No. 17.31) , Providing And Fixng 8 Mm Dia C.P./ S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer-In-Charge (Dsr No. 17.16A) , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. (Dsr No. 17.28) , Semi Rigid Pipe (Dsr No. 17.28.1) , 32 Mm Dia (Dsr No. 17.28.1.1) , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. (Dsr No. 17.71) , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. (Dsr No. 17.73) , 450 Mm Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms. (Dsr No. 17.73.1) , Providing And Fixing Toilet Paper Holder: (Dsr No. 17.34) , C.P. Brass (Dsr No. 17.34.1) , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931: (Dsr No. 18.49) , 15 Mm Nominal Bore (Dsr No. 18.49.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. (Dsr No. 18.51) , 15 Mm Nominal Bore (Dsr No. 18.51.1) , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete: (Dsr No. 18.18) , 18 Mm Nominal Bore (Dsr No. 18.18.2) , Providing And Fixing Grab Rail Of Stainless Steel Pipe 1-1/4 And Fitting Of Grade Aisi 304 As Per Jis Standard 3448 Including Fitting And Fixing Or Pipe With Clamps At 1.00 M Spacing Including Cutting And Making Good The Walls Complete As Per Direction Of Engineer-In-Charge. (Nsi) , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete. (Dsr No. 9.97) , 200X10 Mm (Dsr No. 9.97.3) , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. (Dsr No. 9.101) , Twin Rubber Stopper (Dsr No. 9.101.2) , Providing And Fixing Of Superior Quality Heavy Duty Isi Marked Sanitary Napkin Vending Machine, Incinerator, Battery And Happy Days Pad Complete In All Respects (Nsi) , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required (Dsr No. 10.25) , In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Work (Dsr No. 10.25.2) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete (Dsr No. 13.80) , Providing And Fixig Square-Mouth S.W. Gully Trap Clss Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside) The Weight F Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: (Dsr No. 19.4) , 100X100 Mm Size P Type (Dsr No. 19.4.1) , With Commom Burnt Clay F.P.S. (Non Modular Bricks Of Class Designation 7.5 (Dsr No. 19.4.1.1) , Providing And Laying Cement Concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design: (Dsr No. 19.2) , 150 Mm Diameter S.W. Pipe (Dsr No. 19.2.2) , Making Connection Of Drain Or Sewer Line With Existing Manhole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Cement Plastered On Both Sides With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With Floating Coat Of Neat Cement And Making Necessary Channels For The Drain Etc. Complete: (Dsr No. 19.21) , For Pipes 100 To 250 Mm Diameter (Dsr No. 19.21.1) , Providing And Fixing In Position Pre-Cast Reinforced Cement Concrete Manhole Cover And Frame Of Required Shape And Approved Quality. (Dsr No. 19.19) , L D- 2.5 (Dsr No. 19.19.1) , Rectangular Shape 600X450 Mm Internal Dimensions (Dsr No. 19.19.1.1) , Providing And Fixing Soap Dispensor And Fitting Complete In All Respects (Nsi) , Providing And Fixing Acralicsheet With Silver Remark Engraving Plate 12X18 In Position At Required Place To The Entire Satisfaction Of Engineer-In -Charge (Nsi) , Providing And Fixing Sun Board Printing With Lamination On 5Mm Sun Board Of Size 6 X 2 To Be Fixed At The Height Of 12 From Ngl, Leveled In Position To The Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing And Fixing Acrylic Sheet Of With Silver Remark Engraving Plate 12 X 12 In Position At Required Place To The Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing And Fixing Sun Board Printing With Lamination On 5Mm Sub Board Of Size 24 X 30 To Be Fixed At The Height Og 12 From Ngl, Leveled In Position To The Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing And Fixing 50 Watt Led Flood Light With Bracket Out Side On The Wall Complete In All Respects (Nsi) , Providing And Fixing Of Crompton Greeves 1 Hp Water Pump With Help Of Fasterners To Be Fixed At Site As Per Entire Satisfaction Of Engineer-In-Charge (Nsi) , Providing, Fixing And Installation Of Inverter With Battery Of Minimum Back Up Of 8 Hours Including The Cost Of Wiring, Switches Board Etc. Complete In All Respect To The Entire Satisfaction Of Iec Inverter (With 2 Year Warranty Period) Make Microtek/V-Guard/Luminious.Battery 12V/500H Tubular Battery Make Exide/Microtek/Luminious Etc (With 3 Year Warranty Period (Nsi) , Providing And Fixing Of 1.5 Mm Single Core Pvc Insulated Copper Cable For Wiring At Toilet Block. (Nsi) , Providing And Fixing Of 0.75 Mm Single Core Pvc Insulated Copper Cable For Earthing At Toilet Block (Nsi) , Providing And Fixing Of Led Round Concealed Light Complete Set Type 15 W Make: Crompton/Havells (Nsi) , Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required (Nsi) , 75 Mm X 75 Mm X 60 Mm Deep (Nsi) , 100 Mm X 100 Mm X 60 Mmm Deep (Nsi) , 150 Mm X 150 Mm X 60 Mmm Deep (Nsi) , Supplying And Fixing Following Piano Type Switch/ Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required (Nsi) , 5/6 Amps Switch (Nsi) , 3 Pin 5/6 A Socket Outlet (Nsi) , Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Mdular Base & Cover Plate For Modular Switches In Respect As Required (Nsi) , 8 Module (125 Mm X 125 Mm) (Nsi) , Supply And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. (Nsi) , 3 Pin 5/6 A Socket Outlet (Nsi) , Providing And Fixing Ceiling Fan 1200Mm (48) Sweep Including All Accessories Complete To Entire Satisfaction Of Eic. Make: Crompton/ Usha/Khaitan/Bajaj (Nsi) , Providing And Fixing Led Tube Light Complete Set Type 36W, 1=4Ft, Make: Philips/Crompton/Havells (Nsi) , Providing And Fixing Of Exhaust Fan Of Double Ball Bearing 12 Sweep Including All Necessary Accessories Complete To Entire Satisfaction Of Eic. Make: Crompton/Havells/Bajaj/Gec (Nsi) , Wiring For Light Point/Fan Point/Exhuast Fan Point/Call Bel Point With 1.5 Sq. Mm. Frls Pvc Insulated Copper Conductor Single Core Cable In Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Singlecore Cable Etc. As Required (Nsi) , Wiring For Light/Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. (Nsi) , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Nsi) , Double Pole (Nsi) , Supplying And Fixing Metal Box Of Following Sizxes (Nominal Size) On Surface Or Inrecess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required. (Nsi) , 200Mm X 150Mm X 100 Mm , Supplying And Fixing Following Modular Switch/Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required (Nsi) , 15/16 Annual Periodical Maintenance Switch (Nsi) , 6 Pin 15/16 Annual Periodical Maintenance Socket Outlet (Nsi) , Supplying And Fixing Following Way, Single Pole And Netural, Sheet Steel, Mcb Distribution Board Consumer Unit 240 Volts, On Surface/Reess, Complete With Timed Copper Bus Bar Netural Bus Bar, Earth Bus Bar, Hinged Front Acrylic Cover For The Mcb Knobs, Detachable Gland Plate, Interconnections, Phosphatized And Powder Painted Including Earthling Etc. As Required (But Without Mc/Pccb/Isolator) 2*4 Way (Nsi) , Note:- The Old Material To Be Recovered From Site Will Be Returned To The Department And Will Be Recorded In M.A.S. Register.
Contract Date: Jun 22, 2026 Contract Value : 3.51 Lakh
Local Bodies No of Bidders 3
34.
Public Administrative Department #11321705 AOC
Bids Are invited for Boq1 Boq1 35 Pcs Dinner Set Ceramic , Bowl Ceramic , Dining Spoon Set , Tissue Box , S Broom , Dust Bin With Paddle Big , Dust Bin With Paddle Medium , Hanger , Eagle Floor Cleaner , Domestic Gas Pipe , Hot Case Big Milton , Hot Case Small Milton , Lunch Box 5 Compartment , Lunch Box 4 Compartment , Tissue Base , Tong , Tin Cutter Bottle Oppner Combo , Foot Mat , Glass Set For Wine , Tray For Snacks , Wine Opner Multi High End , Bathroom Sleeper , Dressing Table Robien Dreser , Borosil Glass Set , Knife Set , Fork Set , Glass Jug 2 Litre , Quilt Double - High Quality , Blanket Double High Quality , Bed Cover Good Quality , Quilt Cover Good Quality , Pillow High Quality , Hand Towel , Table Mat , Duster Kitchen , Dusting Cloth , Container Crystal , Cup Plate Set , Curten Rod 12Feet , Curten Rod Holder , Laundry Bag , Gloves For Domestic Use , Health Faucet , Pvc Pipe 6 Inch , Elbow 40Mm , Socket 40Mm , Solvent , Sink Couplin , Waist Pipe , Plywood 6Mm , Silicon , White Cement , Silicon Gun , Angle Valve , Taflon Tape , Connection Pipe , Epoxy 1 Kg , Tile Cutting Blade , Patti , Pr Fixel 1 Litre , White Cement , Flow Pipe 90Mm , Socket 90 Mm , Disk Ic , Pvc 24 , Gi Pipe Supreme , Ppr Welding Machine , Fta 25 By Half , Fta 25 X 3By4 , Mta 25 X Half , Mta 25 X 3 By 4 , Plug 3 By 4 , Towel Rod , Sink Jali , Elbow 110Mm , Flow Trap 110X110mm , Pvc Conection Nozel , Sink Mixer , Drain Pipe Cleaner , Tv 43 Inch Hd , Humidifier , Led Bulb , Wire Havels 4Mm , 12 Module Plate , 12 Module Box , 16 Switch , 16 Soket , 16 3 Pin Top , Iron Dry , Iron Board , Microwave Revolving Glass Plate , Microwave Screw , Heater With Coil , Extension Board 16 , Heater Oil , Water Purifier Ro , Inverter , Battery , 16 Ss Combine , Cartridge 12A Original , Cartridge 88A Original , Water Purifier Memorin , Water Purifie Uf Big , Water Purifie Sediment Filter , Water Purifie Carbon Filter , Water Purifie Pree Filter , Pree Boil With Fitter , Concealed Light , Led Pannel Round Havells , G.Coil Switch , Vaccume Cleaner Heavy Duty , Spin Mop , Table L Glass , Battery Distil Water 30 Litre , Battery 12V , Remote Control Bell , Door Bell Wireless , Geaser Water Heater Total Quantity : 347
Contract Date: Ref. Documents Contract Value : 7.15 Lakh
Government Departments No of Bidders 3
35.
Tourism #11320518 Technical Bid
Tender For Tourism Development Work Of Shri Ramjanaki Temple, Kotawari In Shahjahanpur District.-1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. All Kinds Of Soil Dsr-2.6.1 170.25 Cum 133.12 127.80 21757.52 In All Kind Of Soil Upto 1.5M To 3.0M. Depth 2.6.1+2.26.1 18.74 Cum 228.22 219.09 4106.24 In All Kind Of Soil Upto 3.0M To 4.5M. Depth 2.6.1+(2.26.1* 2) 6.37 Cum 323.31 310.38 1977.88 2 Excavation Of Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The Trenches Or Into The Space Between The Building And Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Sur-Plus Earth As Directed By The Engineer Incharge Up To A Distance Of 30 Meters From The Foundation Trenches. Dsr-2.1.1 35.61 Cum 97.38 93.49 3329.14 3 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. Dsr-2.25 8.70 Cum 147.00 141.12 1227.84 4 Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete Dsr-2.25(A) 55.60 Cum 525.36 504.34 28041.40 5 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) Dsr-4.1.8 70.78 Cum 5108.83 4904.47 347162.56 6 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. Dsr-2.27 26.31 Cum 1592.76 1529.05 40229.27 7 Diluting And Injecting Chemical Emulsion For Postonstructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration Dsr-2.35.3.1 194.47 Sqm 232.53 223.23 43411.24 8 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). Dsr-5.3 82.66 Cum 8628.83 8283.68 684729.10 9 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) Footing Dsr-5.1.2 21.98 Cum 6784.08 6512.72 143149.60 10 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Dsr-5.2.2 22.97 Cum 8139.44 7813.86 179484.39 Abstract Of Cost Delhi Schedule Of Rate Effective From 12/07/2023 X (0.735X106/107X1.03) Has Been Followed. Proposed Tourism Development Of Ramjanki Temple At Kotawari, Tilhar, Sahjahanpur, U.P. 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Dsr-5.9.5 257.49 Sqm 552.28 530.19 136518.66 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform Dsr-5.9.3 407.10 Sqm 695.41 667.60 271778.96 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Dsr-5.9.1 63.96 Sqm 294.10 282.34 18058.37 14 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts Dsr-5.9.6 208.86 Sqm 720.95 692.11 144554.66 15 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dsr-6.1.1 16.84 Cum 5527.80 5306.69 89341.45 16 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.1.2 51.30 Cum 5349.01 5135.05 263427.92 17 Providing And Laying Damp-Proof Course 50Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sources). Dsr-4.11 2.14 Sqm 371.80 356.93 763.83 18 Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. Dsr-4.13 44.55 Sqm 109.61 105.22 4687.75 19 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Dsr-6.4.2 80.04 Cum 6829.23 6556.06 524747.32 20 Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Dsr-6.13.2 60.18 Sqm 842.82 809.11 48692.17 21 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More Dsr-5.22A.6 186.64 Qtl 8088.48 7764.94 1449250.34 22 15 Mm Cement Plaster On Plinth Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Coarse Sand) Dsr-13.5.1 65.74 Sqm 308.80 296.45 19488.62 23 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.5.2 252.10 Sqm 296.50 284.64 71758.35 24 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Coarse Sand) Dsr-13.4.2 609.85 Sqm 257.73 247.42 150888.63 25 Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To R.C.C. Projections. Dsr-5.30 315.01 Rm 58.80 56.45 17781.09 26 Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate Dsr-11.3.1 29.40 Sqm 460.63 442.21 13000.95 27 Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement.18 Mm Thick Dsr-11.6.1 3.35 Sqm 496.52 476.66 1596.81 26 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm Dsr-11.41.2 137.75 Sqm 1165.05 1118.45 154065.99 27 Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To |.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm Dsr-11.46.2 10.17 Sqm 1217.25 1168.56 11884.22 28 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Dsr-11.37A 148.53 Sqm 812.00 779.52 115781.77 29 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Dsr-11.39 4.40 Sqm 997.47 957.57 4213.30 30 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Ordinary Cement Without Any Pigment 11.20.4 6.12 Sqm 792.24 760.55 4654.54 31 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 35 Mm Thick Dsr-9.5.1.1 6.30 Sqm 3083.86 2960.50 18651.18 32 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors,Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately) 30 Mm Thick Dsr-9.5.1.2 83.22 Sqm 2810.38 2697.97 224524.67 33 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws Dsr-9.21.1 15.33 Sqm 1794.43 1722.65 26408.23 34 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10X15Cm 1:3:6 Mix (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). Dsr-9.53 128.00 Nos 171.63 164.77 21090.11 35 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding Dsr-9.48.1 937.05 Kg 164.32 157.75 147816.54 36 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10X10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). Dsr-10.13.1 100.80 Kg 106.27 102.02 10283.67 37 Providing And Fixing Angle Iron Frames For Doors, Windows And Ventilators Of Mild Steel Angle Sections Of Size 35X35X5 Mm, Joints Mitred And Welded By Angle Iron 35X35X5 Mm Or 35X 5 Mm Flat Pieces To The Existing T-Iron Frame Or To The Wall With Dash Fastener, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer, All Complete As Per The Direction Of Engineer-In-Charge. Dsr-10.31 125.00 Kg 97.87 93.96 11744.60 38 Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Dsr 10.28 133.33 Kg 579.28 556.11 74146.05 39 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).(Sal Wood) Dsr-9.1.2 1.61 Cum 87387.28 83891.79 135065.79 40 Fixing Of Door, Windows/Ventilators Chaukhats In Position. (A) Door Chaukhats Above 1.5 Sqm To 5.0Sqm Mr 19.00 Nos 150.00 144.00 2736.00 (B) Window Chaukhats Above 1.5 Sqm 12.00 Nos 100.00 96.00 1152.00 (C) Ventilator Chaukhats 7.00 Nos 50.00 48.00 336.00 41 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work (Two Or More Coats Applied @ 1.43 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) Dsr-13.47.1 407.00 Sqm 128.32 123.19 50137.46 42 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Dsr-13.41.1 434.15 Sqm 139.23 133.66 58030.01 43 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Dsr-13.80 841.15 Sqm 117.03 112.35 94505.07 44 Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete :250X16 Mm Dsr-9.62.2 11.00 Nos 145.27 139.46 1534.05 45 Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete : 250X10 Mm Dsr-9.63.1 21.00 Nos 62.92 60.41 1268.53 200X10 Mm Dsr-9.63.2 65.00 Nos 52.05 49.97 3247.81 46 Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete :100 Mm Dsr-9.66.2 54.00 Nos 24.41 23.44 1265.50 47 Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete Dsr-9.82 1.00 Nos 91.23 87.59 87.59 48 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: (A) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. (B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm Dsr-22.7.1 198.55 Sqm 1263.41 1212.87 240815.58 49 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture Dsr-13.48.3 144.65 Sqm 128.02 122.90 17777.47 50 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture Dsr-13.48.2 209.70 Sqm 132.18 126.90 26610.03 51 Providing & Fixing Panes Of Glass With Equal Or Equivalent I.S.I Marked Quality Putty. Brads And Springs And Including Supply Of All Materials And Labour Etc Complete . 3.8 To 4.7 Mm Thick Dsr-10.30.1 44.76 Sqm 805.96 773.72 34631.80 52 Supply And Fixing Of Drop Down Rail / Grab Bars Mr 4.00 Nos. 4400.00 4224.00 16896.00 53 Providing, Driving With Hydraulic Piling Rigs With Power Units And Installing Driven Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Shoe And The Length Of Pile To Be Embedded In The Pile Cap Etc. All Complete. (Length Of Pile For Payment Shall Be Measured From Top Of Shoe To The Bottom Of Pile Cap) : 400 Mm Dia Piles Dsr-20.1.1 48.00 Rm 2075.18 1992.17 95624.30 54 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) : 30 Mm Thick Dsr-8.14.1.5 50.74 Sqm 3971.79 3812.92 193478.98 55 Stone Work In Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Including Pointing With Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade Both Face Dressed Red Sand Stone Dsr-7.12.1.1 3.56 Cum 51218.78 49170.03 175241.97 56 Extra For Stone Work Ashlar Sunk Or Moulded Or Sunk And Moulded Or Carved In : Triangular Or Square Or Rectangular Pillars Dsr-7.21.1 3.56 Cum 2834.15 2720.79 9696.89 57 Providing And Fixing Stainless Steel Cramps Of Required Size And Shape For Anchoring Stone Wall Lining To The Backing Or Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases In Stone And Holes In Walls Wherever Required. Dsr-8.15 99.58 Kg. 535.78 514.35 51219.04 58 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :Red Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 50Mm Dsr 8.14.1.3 37.80 Sqm. 4342.28 4168.59 157572.62 59 Providing And Fixing Copper Pins 7.5 Cm Long 6 Mm Diameter For Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases. Dsr 8.16 30.00 Nos. 32.92 31.61 948.21 60 Providing And Fixing Stone Jali 40 Mm Thick Throughout In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc. Red Sand Stone Dsr 7.33.1 4.50 Sqm. 11198.29 10750.35 48376.59 61 Stone Work, Plain In Copings, Cornices, String Courses And Plinth Courses, Upto 75 Mm Thick In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade.: Red Sand Stone Dsr 7.32.1 0.47 Cum. 70303.46 67491.32 31720.92 62 Carving & Engraving Work On Red Sand Stone (Labour Only) M.R. 9.73 Sqm. 15615.00 14990.40 145856.59 63 Manufacturing, Supplying And Fixing Retro Reflective Overhead Signage Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity And Encapsulated Lens Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iii Of Astm-D-4956-01 As Approved By Engineer-In-Charge, Letters, Borders Etc. As Per Irc : 67-2001 In Silver White With Blue Colour Back Ground And With High Intensity Grade, Pasted On Substrate By Pressure Sensitive Adhesive Backing Which Shall Be Activated By Applying Pressure Conforming To Class Ii Of Astm-D-4956-01 And Fixing The Same To The Plate Of Structural Frame Work By Means Of Suitable Sized Aluminium Alloys, Rivets Or Bolts & Nuts @ 300 Mm Centre To Centre All Along The Periphery As Well As In Two Vertical Rows Along With Theft Resistant Measures, Including The Cost Of Painting With Two Or More Coats Of Epoxy Paint In Grey Colour On The Back Side Of Aluminium Sheet Including Appropriate Priming Coat. The Rate Includes The Cost Of Rounding Off The Corners, Lowering Down The Structural Frame Work From The Gantry, Fixing And Erecting The Same In Position All Complete As Per Drawings, Specification And Direction Of The Engineerincharge.( Structural Frame Work Including M.S. Plate To Be Provided Separately. Rectangular Area Of The Sheet Only Shall Be Measured For Payment). Overhead Informatory Road Signage Dsr 16.60.1 8.64 Sqm. 4409.78 4233.39 36576.45 64 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Dsr 8.2.2.2 34.45 Sqm 3852.10 3698.01 127396.50 65 Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. Dsr-4.17 6.00 Sqm 561.96 539.48 3236.87 66 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50 Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-35 Grade With Approved Colour Design And Pattern Dsr-16.91.2 207.07 Sqm 818.60 785.85 162723.31 1 Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fitting And Fixtures Completed Including Cutting And Making Good The Walls And Floors Wherever Required.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests 17.1.1 2.00 Nos. 5075.38 4872.36 9744.73 2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Isi Marked White Solid Plastic Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required. W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 17.2.1 3.00 Nos. 4886.50 4691.04 14073.11 3 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require A) White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap. 17.7.4 4.00 Nos. 1409.35 1352.98 5411.91 4 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required A) One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern 17.4.1 3.00 Nos. 4918.90 4722.14 14166.42 5 Providing And Fixing Flexible P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc Waste Fittings Complete. Flexible Pipe 17.28.2 A) 32Mm Dia 17.28.2.1 4.00 Nos. 89.66 86.07 344.29 B) 40Mm Dia 17.28.2.2 2.00 Nos. 89.66 86.07 172.15 6 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 17.31 4.00 No. 1205.92 1157.69 4630.74 7 Providing And Fixing Cp Brass Single Lever Lelephonic Wall Mixture Of Quality & Make And As Per Thedirection Of Enginer-Incharge. A) 15Mm Dia Nominal Dia. 17.22B 2.00 Each 5205.39 4997.17 9994.34 8 Providing And Fixing 8 Mm Dia C.P./S.S. Jet With Flexible Tube Upto 1 Meter Long With S.S. Triangular Plate For Eureopean Type W.C. Of Quality And Make As Approved By Engineer-In-Charge. 15Mm Nominal Bore 17.16A 2.00 Each 261.85 251.38 502.76 Sanitary Fixtures & Accessories : I 9 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. Dsr-17.73.2 1.00 Each 531.69 510.43 510.43 10 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. Dsr-18.65 1.00 Each 83.58 80.24 80.24 11 Providing And Fixing C.P. Brass Ablution Health Faucet Assembly With 1.0 M Long Braided Pvc Hose With Mounting Bracket Fixed On Wall Complete.[For Ewc]-Make-Jaquar Ald565 Mr 2.00 Each 1705.00 1636.80 3273.60 12 Providing And Fixing C.P. Brass Two-Way Angle Valve For Ewc Points & For Fixing Ablution Health Faucet Of Approved Quality Conforming To Is:8931. 15 Mm Nominal Bore-Essco Sqt 526A Mr 2.00 Each 1335.00 1281.60 2563.20 1 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion . (I) Single Socketed Pipes. A) 110Mm Diameter 12.41.2 31.30 Mtr 283.04 271.72 8504.80 2 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over Pvc Sheet 1M X 1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement,Punning,Rounding The Edges And Making And Finishing The Outlet Complete. A) 110Mm 12.22 7.00 Nos. 223.68 214.73 1503.13 3 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. A) 110Mm 12.43.2 20.00 Nos. 278.47 267.33 5346.54 4 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I)Single Socketed Pipes. 110 Mm Diameter 12.41.2 Rm. 283.04 271.72 5 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. Dsr-12.44 8.00 Nos. 41.02 39.38 315.06 6 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Nsr 20.00 Rm. 485.00 465.60 9312.00 B) 90Mm Dia P.V.C. Pipe Nsr 25.00 Rm. 390.00 374.40 9360.00 6 Providing & Fixing Upvc Floor Trap Of Self Cleansing Design With Cp Jali Complete In All Respects. (Make : Supreme / Finolex / Prince) P-Trap Type Floor Trap 110 X 90 Mm Nsr 12.00 No. 195.00 187.20 2246.40 7 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion.. (Make : Supreme / Finolex / Prince) Door Tee 110X110X110 Mm Nsr 2.00 No. 280.00 268.80 537.60 110X110X90 Mm Nsr 2.00 No. 200.00 192.00 384.00 Bend 110 Mm Nsr 2.00 No. 170.00 163.20 326.40 Soil Waste & Vent Pipes And Fittings - Ii 90 Mm Nsr 2.00 No. 160.00 153.60 307.20 1 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.Lls Etc. (Internal Work) I) Exposed On Wall A) 32Mm Nominal Dia Pipe 18.9.4 30.00 Rm. 328.94 315.78 9473.44 3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Outer Dia Pipes 18.7.3 20.00 Rm. 301.15 289.11 5782.13 4 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testiang Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work Including Cutting Chases And Making Good The Walls Etc. A) 15Mm Dia Nominal Outer Dia Pipes 18.8.1 70.00 Rm. 373.34 358.40 25088.28 B) 20Mm Dia Nominal Outer Dia Pipes 18.8.2 20.00 Rm. 403.19 387.06 7741.18 C) 25Mm Dia Nominal Outer Dia Pipes 18.8.3 Rm. 470.42 451.60 5 Providing & Fixing G.I. Pipes Complete With G.I. Fittings & Clamps Including Cutting & Making Good The Walls Etc. (Internal Work) I) Exposed On Wall A) 25Mm Dia Nominal Bore (Medium Duty) Dsr-18.10.3 20.00 Rm. 413.76 397.21 7944.21 Ii) Concealed Pipe Including Painting With Anticorrosive Bitumatic Paint, Cutting Chases And Making Good The Wall. A) 15Mm Dia Nominal Bore Dsr-18.11.1 15.00 Rm. 435.32 417.91 6268.65 2 Painting G.I. Pipes And Fittings With Synthetic Enamel White Paint Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. A) 15Mm Dia Nominal Bore. Dsr-18.38.1 15.00 Rm. 14.55 13.97 209.51 B) 25Mm Dia Nominal Bore. Dsr-18.38.3 10.00 Rm. 22.69 21.78 217.79 2 Providing And Fixing 45 Cm Long Unplasticised Pvc Connection Pipe With Brass Unions. A) 15Mm Nominal Bore Dsr18.21.2.1 4.00 Nos. 73.31 70.38 281.51 5 Providing & Fixing Cp Brass Bib Cock Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.49.1 7.00 Nos. 380.09 364.88 2554.19 6 Providing & Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. A) 15Mm Nominal Bore 18.51.1 7.00 Nos. 599.19 575.22 4026.57 7 Providing & Fixing C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is 8931 A) 15Mm Nominal Bore 18.53.1 14.00 Nos. 430.71 413.48 5788.75 8 Providing And Fixing Gun Metal Gate Valve With Wheel Of Approved Quality. A) 25Mm Dia Nominal Bore 18.17.1 2.00 Each 466.78 448.11 896.23 B) 32Mm Dia Nominal Bore 18.17.2 1.00 Each 517.18 496.50 496.50 C) 50Mm Dia Nominal Bore 18.17.4 Each 769.96 739.16 Water Supply Pipes And Fittings - Iii 9 Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete 20Mm Dia Nominal Bore 18.18.2 1.00 Each 346.86 332.99 332.99 A) 25 Mm Nominal Bore 18.18.3 2.00 Nos. 348.03 334.10 668.21 10 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Of Approved Brand And Manufacture With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 18.48 A) Circular Tank 18.48 2500.00 Ltrs 8.25 7.92 19799.33 11 Providing And Fixing Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75X50Cm Deep And 1.8Cm Thick Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1Cement: 2Coarse Sand: 4Graded Stone Aggregate 6Mm Nominal Size) As Per Direction Of Engineerin-Charge And Finished Smooth. 8.10 Granite Stone Of Approved Shade Dsr-8.10.2 1.08 Sqm. 3038.79 2917.23 3150.61 1 Providing & Fixing Soil, Waste And Vent Pipes. A) 100Mm Dia Centrifugally Cast Iron S & S Pipe. Dsr17.35.1.2 6.00 Rm. 885.53 850.11 5100.67 2 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes & Fitting Of Diameters. A) 100Mm Dsr-17.58.1 2.00 Each 466.86 448.18 896.37 3 Providing & Fixing M.S. Holder Bat Clamps Of Approved Design To Sand Cast Iron/Centrifugally Cast (Spun) Iron S & S Pipe Embeded In & Including Cement Concrete Blocks 10X10X10Cm. Of 1:2:4 Mix (1 Cement : 2 Coarse : 4 Graded Stone Aggregate 20Mm Nominal Size). Including Cost Of Cutting Holes & Making Good The Walls Etc. A) For 100Mm Dia Pipe. Dsr-17.37.1 2.00 Each 272.13 261.24 522.49 4 Providing & Fixing Cast Iron Trap Of Self Cleansing Design With Or Without Ventarm Complete, Including Cost Of Cutting & Making Good The Walls & Floors. A) 100Mm Inlet & 75Mm Outlet. Dsr17.60.2.1 1.00 No. 1481.31 1422.06 1422.06 5 Providing & Fixing Cast Iron Coller. A) 100Mm Dia. Dsr17.57.1.2 2.00 No. 384.85 369.46 738.91 6 Providing And Fixing Plain Cast Iron S & S Sanitary Bend. A) 100Mm Dsr17.39.1.2 2.00 Nos. 427.52 410.42 820.84 1 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. A) 110Mm Dia P.V.C. Pipe Mr 7.50 M 485.00 465.60 3492.00 2 Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber With F.P.S. Bricks Of Class Designation 75 And Water Tight C.I. Cover With Frame Of 300 X 300Mm. Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design. A) 150 X 100 Mm. Size P Type With Sewer Bricks Conforming To Is : 4885 Dsr-19.4.2.1 1.00 Nos 2050.58 1968.56 1968.56 Soil Waste & Vent Pipes And Fittings - Ii Schedule Of Quantities For Internal Sewerage System - Iv 3 Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Rcc Top Slab With 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size) Inside Plastering 12Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design 19.7 Inside Size 90X80Cms And 45Cms Deep Including Ci Cover With Frame (Light Duty) 455X610Mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15Kg). 19.7.1 With Fps Bricks Of Class Designation 150 Dsr-19.7.1.1 1.00 Each 9577.59 9194.49 9194.49 External Sewerage Works 1 Excavating Trenches In All Kind Of Soil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. Up To 1.50 M Depth Pipes 80 Mm To 300 Mm Diameter 2.10.1.2 20.00 Rm 264.10 253.54 5070.79 2 Providing And Fixing In Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To (Hsn Code: 3917) Type B Including Jointing With Seal Ring. (I) Double Socketed Pipes. 160Mm Dia Under Floor (For External Sewer) Nsr 20.00 Metre 1190.00 1142.40 22848.00 3 Constructing Brick Masonry Manhole With F.P.S. Bricks In Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Rcc Top Slab With 1 : 2 : 4 Mix (1 Cement : 2 Coarse Sand : 4 Grade Stone Aggregate 20Mm Nominal Size); Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1Cement 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size) Finishd With A Floating Coat Of Neat Cement Complete As Per Standard Design Inside Size 90 X 80 Cm & 45 Cm Deep Including Ci Cover With Frame (Light Duty) 455 X 610 Mm Internal Dimension Total Wt. Of Cover & Frame To Be Not Less Than 38 Kg (Wt. Of Cover 23 Kg And Wt. Of Frame 15 Kg) 19.7.1.1 3.00 Nos 9577.59 9194.49 27583.46 4 Extra For Depth For Manhole With F.P.S. Bricks Size 90 X 80 Cm 19.8.1.1 0.30 Rm 6618.83 6354.07 1906.22 5 Providing M.S. Foot Rests Including Fixing In Manholes With 20*20*10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design : With 20 X 20 Mm Square Bar 19.15.1 3.00 Nos 408.51 392.17 1176.51 6 Providing And Fixing Square Mouth S.W. Gully Trap Grade `A Complete With C.I. Grating Brick Masonry Chamber With F.P.S Bricks And Water Tight Ci Cover With Frame Of 300 X 300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 180 X 150 Mm. Size P Type 19.4.3.1 2.00 Nos 2101.54 2017.48 4034.96 7 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 19.32.1 1.00 Nos 20145.75 19339.92 19339.92 8 Providing M.S. Foot Rests Including Fixing In Manholes With 20X20X10 Cm Cement Concrete Blocks 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design With 20X20 Mm Square Bar Dsr-19.15.1 8.00 Nos. 408.51 392.17 3137.37 9 Providing And Fixing S.C.I. Tee 150 Mm At The Inlet And Outlet Of Septic Tank. Dsr-7087 2.00 Nos. 621.00 596.16 1192.32 10 Providing And Fixing Soil, Waste And Vent Pipes:75 Mm Diameter Sand Cast Iron S&S Pipe As Per Is: 1729 Dsr17.35.2.1 3.00 Rmt. 783.54 752.19 2256.58 11 Providing & Fixing Of 75Mm Dia Sand Cast Iron S&S As Per Is - 1729 Terminal Guard. Dsr17.56.2.1 2.00 Nos. 255.52 245.30 490.59 12 Providing & Fixing 75Mm Plane Sand Cast Iron S&S Bend Of Required Drgtee. Dsr17.39.2.1 2.00 Nos. 282.18 270.89 541.78 13 Providing Lead Caulked Joints To Sand Cast Iron/ Cetrifugally Cast (Squn) Irons Pipes & Fitting Of 50 Mm Dia Dsr-17.58.2 2.00 Nos. 394.67 378.89 757.77 14 Providing And Fixing In Position Precast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality.M.D. -10- Circular Shape 500Mm Internal Diameter Dsr19.19.2.2 2.00 Nos. 879.42 844.24 1688.49 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.10.3 51.00 Each 1115.37 1070.76 54608.68 2 Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required Dsr 1.11 4.00 Each 1187.60 1140.10 4560.39 3 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Dsr 1.21.1 17.00 Metre 97.32 93.43 1588.26 4 Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire Dsr 1.14.1 650.00 Metre 177.15 170.07 110542.86 5 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Dsr 1.14.2 188.00 Metre 285.12 273.71 51457.72 6 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Dsr 1.14.3 202.00 Metre 253.94 243.79 49244.67 7 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire Dsr 1.14.4 105.00 Metre 333.78 320.42 33644.59 8 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required Dsr 1.32 22.00 Each 445.54 427.72 9409.83 9 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required Dsr 1.34 15.00 Each 99.60 95.62 1434.25 Electrical Works 10 Installation ,Testing, Commissioning Of Wall Bracket /Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Ls/Cfl/Led Lamps Per Fitting, Complete With All Accessories Including Connections Etc. As Required. Dsr 1.35 1.00 Each 90.48 86.86 86.86 11 Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Lighter (Round/ Square/ Rectangular) Smd Type Of Following Body Material With Pmma And Prismatic Diffuser And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140-270 Volt, Frequency 50/60 Hz, Operating Temp Range -50C To 400C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd < 10% , P. F.≥0.95, Ip20, Cri >80, Ugr (Unified Glare Rating) < 19, Flicker Free (Flicker Should Be Below 5%), Life Time (Led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K /4000°K / 5700°K / 6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Colour Matching) <3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Confirming To Relevant Bis Standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 And <120 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) Powder Coated Die Cast /Extruded Aluminium Body Including Trim 18 Watt Mr 19.00 Each 700.00 672.00 12768.00 12 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required Dsr-5.4 3.00 Each 5681.03 5453.79 16361.37 13 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) Dsr 5.9 55.00 Metre 109.48 105.11 5780.78 14 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A) Single Pole Dsr-2.10.1 9.00 Each 194.64 186.85 1681.68 15 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 6 Way (4 + 12), Double Door Dsr-2.3.1 2.00 Each 1677.24 1610.15 3220.30 16 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) A) 4 Way (4 + 12), Double Door Dsr-2.4.1 1.00 Each 3110.42 2986.01 2986.01 17 Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Dsr-2.10.3 2.00 Each 498.76 478.81 957.62 16 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required Dsr 1.45 10.00 Each 257.74 247.43 2474.35 17 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Dsr 1.25 10.00 Each 280.55 269.33 2693.32 18 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep Dsr-1.50.1 7.00 Each 342.14 328.45 2299.17 19 Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes Dsr-1.51 7.00 Each 157.38 151.09 1057.62 20 Supply, Installation, Testing And Commissioning Of Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Metal( Aluminium Alloy) Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Steel/Al Body Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum As Below, 350 Rpm (Tolerance As Per Is : 374-2019), Thd (Total Harmonic Distortion) Less Than 10%, Suitable For Operation With Regulator For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 0C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Ceiling Fan Compliant To Is 374:2019 Fan I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. 9.2.3 10.00 Each 2075.64 1992.62 19926.18 21 Supplying And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cable 1100 Volts Grade At The Depth Of 750 Mm Bellow Ground Level Over A Cushion Of 75 Mm Thick Sand All Around And Protected With Burnt Bricks On Side And On Top .On Surface The Cable Run Shall Be Fixed On Ms Clamps Etc.Of Suitable Size Or As Directed By The Engineer-Incharge ,Complete In All Respect.The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Following Size 10 Sqmm X 2 Core Mr 164.00 Rm 410.34 393.93 64603.77 22 Supply & Fixing Of 225/230Mm Sweep Ventilating (Light Duty) Exhaust Fan Complete With Metallic Blade (Steel Bird Guard Protector /Copper Motor For High Air Suction Performance /Capacitor Etc.), Noise Level : (45 - 50) Db, Power Consumption : 45 W, Rated Voltage : 230 V, Rated Frequency : 50 Hz, Motor Type : Normal Speed. Complete In All Respect. Mr 7.00 Each 1665.00 1598.40 11188.80 23 Cost For Murals Work 32.40 Sqm 5850.00 5616.00 181958.40 24 Cost For Solar Street Light With 7M Pole Complete 15.00 Nos 22600.00 21696.00 325440.00 25 Cost For C.C. Bench 12.00 Nos 10000.00 9600.00 115200.00 26 Cost For Dustbin 6.00 Nos 4500.00 4320.00 25920.00 1. Trenching In Ordinary Soil Up To A Depth Of 60 Cm Including Removal And Stacking Of Serviceable Materials And Then Disposing Of Surplus Soil, By Spreading And Neatly Levelling Within A Lead Of 50 M And Making Up The Trenched Area To Proper Levels By Filling With Earth Or Earth Mixed With Sludge Or / And Manure Before And After Flooding Trench With Water (Excluding Cost Of Imported Earth, Sludge Or Manure).. (Horti) 2.1 159.24 Cum 74.51 71.53 11389.98 2 Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 5 Km Lead Complete (Earth Measured In Stacks Will Be Reduced By 20% For Payment). (Horti) 2.2 79.62 Cum 491.88 472.21 37597.13 Horticulture 3 Supplying And Stacking At Site Dump Manure From Approved Source, Including Carriage Upto 5 Km Lead Complete (Manure Measured In Stacks Will Be Reduced By 8% For Payment) : Screened Through Sieve Of I.S. Designation 20 Mm (Horti) 2.4.1 106.16 Cum 242.46 232.76 24709.88 4 Spreading Of Sludge, Dump Manure And / Or Good Earth In Required Thickness As Per Direction Of Officer-In-Charge (Cost Of Sludge, Dump Manure And / Or Good Earth To Be Paid Separately). (Horti) 2.8 159.24 Cum 49.94 47.94 7634.64 5 Mixing Earth And Sludge Or Manure In The Required Proportion Specified Or Directed By The Officer-In-Charge (Horti) 2.9 159.24 Cum 34.87 33.47 5330.39 6 Grassing With Selection No.1 Grass Including Watering And Maintenance Of The Lawn For 30 Days Or More Till The Grass Forms A Thick Lawn, Free From Weeds And Fit For Mowing Including Supplying Good Earth, If Needed (The Good Earth Shall Be Paid For Separately). In Rows 5 Cm Apart In Both Directions. (Horti) 2.10.1 530.80 Sqm 16.89 16.21 8604.46 7 Providing And Displaying Of Aglaonema Silver Queen Having 30 Cm To 45 Cm. Ht. With 12 To 15 Leaves, Multi Suckers, Fresh And Healthy Leaves, Well Developed In 25 Cm Dia Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.8 60.00 Each 154.50 148.32 8899.22 (Horti) Dsr 3.8 8 Providing And Displaying Of Aglaonema Dove Variety Having Ht. 30 Cm To 45 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.4 75.00 Each 77.42 74.32 5574.03 (Horti) Dsr 3.4 9 Providing And Displaying Of Aglaonema Marentifolium Variety Having Ht. 23 Cm To 30 Cm With 8 To 10 Leaves, Well Developed, Fresh And Healthy With Colorful Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.10 50.00 Each 64.54 61.96 3097.83 (Horti) Dsr 3.10 10 Providing And Displaying Of Chamaedorea Elegans Palm Having Ht. 60 Cm To 75 Cm, Well Developed With Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.26 50.00 Each 102.70 98.59 4929.51 (Horti) Dsr 3.26 11 Providing And Displaying Of Croton Baby Golden Variety Having Ht.30 Cm And Above, Well Developed With Full Of Fresh And Healthy Leaves In 20 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.28 150.00 Each 39.11 37.55 5632.42 (Horti) Dsr 3.28 12 Providing And Displaying Of Croton Golden (Broad Leaves) Having Ht. 60 Cm To 75 Cm With 3 To 4 Branches, Well Developed, Fresh And Healthy Leaves In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.32 150.00 Each 53.81 51.65 7748.01 (Horti) Dsr 3.32 13 Providing And Displaying Of Dieffenbachia Tropic-Snow Having Ht. 60 Cm & Above With 8 - 10 Leaves, Well Developed, Fresh & Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot & As Per Direction Of The Officer-In-Charge. (Horti) 3.40 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.40 14 Providing And Displaying Of Dieffenbachia Mosaic Having Ht. 30Cm To 45 Cm With 10-12 Leaves, Well Developed, Fresh And Healthy In 25 Cm Size Of Earthen Pot/Plastic Pot. & As Per Direction Of The Officer-In-Charge. (Horti) 3.41 50.00 Each 75.32 72.31 3615.28 (Horti) Dsr 3.41 15 Providing And Displaying Dianthus In Different Colour Well Developed With Fresh & Healthy Foliage 30 Cm Ht., In Full Bloom With Stacking In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.29 50.00 Each 51.79 49.72 2486.05 (Horti) Dsr 4.29 16 Providing And Displaying Gazania Hybrid In Different Colour Well Developed With Fresh & Healthy Foliage With Full Bloom In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-Incharge. (Horti) 4.31 150.00 Each 61.63 59.16 8874.49 (Horti) Dsr 4.31 17 Providing And Displaying Gaillardia Double Hybrid Variety Well Developed 30 To 45 Cm Ht 20 To 30 Fresh & Healthy Flower With Green Painted Bamboo Stick In 25 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.75 120.00 Each 51.85 49.78 5973.11 (Horti) Dsr 4.75 18 Providing And Stacking Of Plant Mogra Of Height 25 To 30 Cm., 2 To 3 Branch In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.88 100.00 Each 44.03 42.27 4226.60 (Horti) Dsr 4.88 19 Providing And Stacking Of Plant Canna Dwarf Of Height 25 To 30 Cm., 2 To 3 Suckers In Earthen Pots Of Size 20 Cm Earthen Pot/Plastic Pot And As Per Direction Of The Officer-In-Charge. (Horti) 4.89 100.00 Each 34.25 32.88 3287.87 (Horti) Dsr 4.89 20 Bush Rose In Different Colour 2 To 3 Healthy Branch 30 Cm And Above Ht. Well Developed With 8 Or More Flowers / Flower Buds In 20 Cm Earthen Pot /Plastic Pot As Per Direction Of The Officer-Incharge. (Horti) 4.90 100.00 Each 24.47 23.49 2349.13 (Horti) Dsr 4.90 21 Providing And Displaying Budded Rose (H.T. Variety) 3 To 4 Healthy Branch 30 Cm And Above Ht. Well Developed With One And Above Flower Plant In 20 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.91 100.00 Each 31.29 30.04 3003.96 (Horti) Dsr 4.91 22 Providing And Displaying Standard Rose (H.T. Variety) 3 To 4 Healthy Branch 90 Cm And Above Ht. Well Developed With One And Above Flowers In 25 Cm Earthen Pot, As Per Direction Of The Officer-In-Charge. (Horti) 4.93 75.00 Each 143.77 138.02 10351.28 (Horti) Dsr 4.93 23 Providing And Stacking Of Plumeria Rubra Of Height 120-150 Cm. With 3-4 Branches And Thick Stem In Big Size Hdpe Bags As Per Direction Of The Officer-In-Charge. (Horti) 7.72 75.00 Each 381.60 366.34 27475.20 (Horti) Dsr 7.72 24 Providing And Stacking Of Polyalthia Longifolia (Ashok) Of Height 180-195 Cm. In Gunny Bag Of Size 30 Cm As Per Direction Of The Officer-Incharge. (Horti) 7.75 75.00 Each 95.40 91.58 6868.80 (Horti) Dsr 7.75 25 Providing And Stacking Of Saraca Indica (Sita Ashok) Of Height 105-120 Cm. In Big Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge. (Horti) 7.80 75.00 Each 76.32 73.27 5495.04 (Horti) Dsr 7.80 26 Providing And Stacking Of Terminalia Arjuna Of Height 150-165 Cm. In Big Polybags Of Size 25 Cm As Per Direction Of The Officerin-Charge. (Horti) 7.88 75.00 Each 57.24 54.95 4121.28 (Horti) Dsr 7.88 27 Providing And Stacking Of Calliandra, Emarginata Of Height 45-60 Cm. In Earthen Pot Of Size 20 Cm As Per Direction Of The Officer-Incharge. (Horti) 8.5 150.00 Each 33.39 32.05 4808.16 (Horti) Dsr 8.5 28 Providing And Stacking Of Nerium Oleander (Kaner) Of Height 60- 75 Cm. With 5-6 Branches In Poly Bags Of Size 25 Cm As Per Direction Of The Officer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
37.
Power #11308038 Technical Bid
Tender For Supply Of Plc Spares Per Nit Annexure-Ia , Belt Sway Switch Type Sw-4020T22 (Make Jayashree-Electro Devices Pvt. Ltd., Upgraded Model . Field Mounted Type Along With Base Plate. Contact -2No+2Nc, Voltage Rating 230/240 Vac Current Rating -10A, 50 Hz. Switch Action-Auto/ Spring Reset Additional Information: Enclosure -Weather Proof With Terminal Block Ip-66, Cast Aluminium Housing, Protection Class-Ip-65, Material Die Cast Aluminium ,Ball/Bush Bearing For Roller & Cam Shaft, Epoxy Painted./ , Pull Chord Switch , Type Sw-4020H22 (Make Jayashree-Electro Devices Pvt.Ltd.,( Equivalent To Type Sw-4020H22 Upgraded Model) Field Mounted Type Contact -2No+2Nc, Voltage Rating 230/240 Vac Current Rating -10A, 50 Hz. Switch Action-Auto/ Spring Reset Additional Information: Enclosure -Weather Proof With Terminal Block Ip-66, Cast Aluminium Housing, Protection Class-Ip-65, Material Die Cast , Vms- Terminal Connector ( Vibration Measuring Sensor ) Part Of Vibration Sensor Ce-680 , Glass Fuse 0.5 Annual Periodical Maintenance For Plc Panels , Siren -Hooter- Specification Ms-190 Siren- Hooter , 24 V-Dc Sound Range 100 Mtrs , Heavy Duty Limit Switch, Identical And Interchangeable With Ag Make Limit Switch, Type-Hls-Ll, Contact-2No+2Nc, Voltage Rating 110/240 V Ac Current Rating -10A,50 Hz. Enclosure-Cast Aluminium Housing. Protection Class-Ip-65, Material Die Cast Aluminium Epoxy Painted. , Rtd Element Type: Pt100/Duplex Temperature Coefficient Of Resistance:0.00385O/°C, Configuration Wire:3, Immersion Lenght:33Mm Stem Dia:06Mm, Spring Length=23Mm, Additional Information: Wire Length -10 Mtrs , Cable Harness For Vibration Sensor For Ring Granulators (Coal Crushers With Allied 2 Pin Connectors (Ms3106f10sl-4S), Cable Length-10 Meter. Detailed Specification:- A) Two Core Copper, Ptfe (Teflon) Insulated Spc-Ee(1000V). B) Ptfe Jacketed. C) Threaded Connector (Ms3106f10sl-4S) To Flying Leads. D) Cable Length-10 Mtrs. Standard-Jss-51034 And Jss-51038 , Pull Chord Wire Rope Dia -5.5+/0.5 Mm, 6*7 Construction Galvanised Wire With Pvc Cover And Bunched Around Jute Thread In The Core. Diameter Of Galvanised Wire-03Mm And Diameter Of Pvc Cover 02 To 03Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
38.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
39.
Educational and Research Institute #11307155 AOC
Tender For Term Contract For Civil Maintenance And Repair Works Of Aiims Raipur Residential Complex; 1. Acid/Alkali Resistant Tile Somany/ Nitco/ Kajariya/ Bell 2. Premium Acrylic Emulsion Paint: Interior Asian (Royale)/ ICI (Velvet)/ Berger (Silk Glamour)/ Nerolac Impression 3. Admixures& Epoxy FOSROC/ Aquomix/ BALENDURA/ROFF/Dr.Fixit/CICO/SIKA/BASF 4. Aluminium Composite Panel Alpolic/ Aluco Bond/ Reynobond/ Euro bond/ Alstrong/Aludewr 5. Aluminium Extrusions/ Sections Hindalco/ Indalco/ Jindal/Indian Aluminium Co. 6. P.T.M.T. Accessories Prayag, PRAKASH, SHURYA/Supreme/Kingston 7. Annealed Float Glass Saint Gobain/ Modi Guard/ Hindustan Pilkington/TATA 8. Centrifugally Cast Iron Pipe & Fittings Neco/ RIF/ Kapilansh/ BIC/SKF/Electrosteel 9. Ceramic Tiles Kajaria/ Somany/ Nitco/ Orient Bell/ Johnson/Varmora/AGL/OASIS/Marbito 10. Cement Concrete Chequrred tiles Raj-Tiles/ Bharat/ Rigid Tiles/Advance/Ultra Tiles/NITCO 11. CP Bottle Trap Parryware / Hindware/ Jaquar/ GRAFDOER by VMS BathwarePvt. Ltd./Prayag 12. CP Brass Bibcock/ Pillarcock/ Stopcock/ Angle Valve/ Concealed Stop Cock & CP fittings (Normal Range) Marc(oriental series)/ Parko/ Jaquar (Continental series)/SPRING COLLECTION OF PRIMA /GEM/ESS/Plumber/ GRAFDOER by VMS BathwarePvt. Ltd. /L&K Metro/Vardhman/’Coral’ series of parryware/’JOY’ & ‘VINTAGE’ series of KEROVIT by Kajaria /Prayag 13. CP Waste Coupling Mark/ GRAFDOER by VMS BathwarePvt. Ltd./ Parko or equivalent /Prayag 14. Curtain Carrier Vista levlor or equivalent. 15. Dash fastener/ Expansion Bolt/Stone Cladding Clamp M/s DevAshish/HILTI/Fischer/Bosch/Wurth/Trixel. 16. Door closer/ floor springs Dorma/ Haffle/ Falcon/Godrej/Dorset/Kich/Sandhu/Hardwyn 17. Drapery Rod Vista Levlor or equivalent. 18. Flushing cistern (single/Dual Flush) as per IS: 7231 Sleek Dual flush PVC cistern of Hindware / ‘Slimline’ofParryware /Prayag 19. EPDM Gasket AnandLescuyer or equivalent. 20. Epoxy Primer & Paints Berger/ Pidilite/ CICO/ BASF/ SIKA/Asian/Nerolac/ICI Kansai Akzo Nobel. 21. Fibre Glass Shelf Kamal/ Bath King or equivalent. 22. Float/Clear/Frosted/Toughened /Refractive Glass Modi Float/ Saint Gobain/ Asahi/AIS/Modiguard. 23. Flush Doors / Shutters as per IS: 2202 Kutty flush door/ Anchor/ Century/ Kitlam/Archid/JAYNA/Ashiyana Brand by Evergreen Industries/ Bhimsaria Door/ Century/ Greenply /Archid/Kitply/Selected Products Company/Jain Doors pvt. ltd./Duro/Durian 24. Flush Valve Aquel/ Marc/ Parryware/ Jaquar /Prayag 25. FRP Shutters/frame Fibre Glass Engineers/ Raipur/ Aashoo Model or equivalent/JAYNA/ Selected Products Company. 26. Galvanized/Stainless Steel Anchor Fasteners Shakti/ Arrow/ Hilti/ Fischer 27. GI fitting Tata/ Jindal/ Zenith/UNIK/AVR/Zoloto. 28. GI Pipe Tata/ Zenith/ Jindal (HISAR)/Prakash Surya. 29. Glass Mosaic Tile Bissazza/ Saon or equivalent. 30. Gun Metal Gate Valve Zoloto/ Leader/ SAINT 31. False Ceiling system Boral Gypsum / India Gypsum/ Laffarge/ St. Gobain(Gyproc)/ Armstrong/Hunter Dougals/Aearolite/Gridsquare/Interarch 32. Hardner Hard crete of Snowcem India/ MC Deritop F.H. 33. Jet Assembly for EWC Parryware/ Jaquar/ Grohe/ Kohler 34. Laminate Marino/ Greenlam/ Decolam/ Century/ Formica/ Kitlam/Action TESA/Sunmica/Durian 35. Low Level PVC Cistern Single flush Sleek model Cistern of PVC of Hindware or ‘Slimline’ model of Parryware, JINDAL /Prayag 36. Melamine Polish Melamine Gold of Asian Paint/Wudfinof pidilite/Timbertone of ICI Dullex/ Beegel. 37. Metal False Ceiling Nittobo / Armstrong / Trac / Durlum / Huntordonglas/Aerolite 38. Mineral Fibre/Calcium silicate Ceiling Armstrong / Nitobo / Daiken / Hunter Douglas/ Aerolite 39. Modular SS Railing System Metallica India / Stark steel Fabricator / D-line International Denmark / Mobel Hardware. 40. M.S .Pipe (Railing) Jindal / Prakash Surya/ Tata/ RINIL 41. Marine Plywood / BWP Ply Kitply / Duro / Century/ Greenlam/ Durian 42. Non asbestos high impact polypropelene reinforced Cement sheet Everest or equivalent 43. Oil Bound Distemper/Dry Distemper Asian (Professional Acrylic Distemper)/Maxilite of ICI / Bisan of Berger/Nerolac (Beauty Acrylic Distemper) 44. Water closet (Orissa Pan/Indian type) & fittings, accessories as per IS : 2556 Parryware / Hindware /’KEROVIT’ by Kajaria/ESSCO by Jaquar. 45. PE-AL-PE Composite pipes Jindal or equivalent. 46. Plastic Connection Pipe Parryware/Kamal Delux or equivalent. 47. Plywood/Veneer Archid/ Kitply/ Green ply/ Century/JAYNA/Green Ply/Merino/Duro/Durian
Contract Date: Jun 18, 2026 Contract Value : 58.17 Lakh
Government Departments No of Bidders 3
Chhattisgarh View Result →
40.
Housing Urban and Rular Development #11306856 AOC
Tender For M.O.W. Work (Additional Room) In Bunglow No. Eg-9/3 And Ek-9/3 Under Section No.1 Survey Sub Dn. Bhopal- 1 M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal 1st Call P.A.C. 29.64 Lakh,as per Building SOR wef 01-01-2024 Schedule Attached Complition period 90 Days Please Enable Macros to View BoQ information SCHEDULE OF ITEMS Name of work : M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal Probable Amount of contract : Rs. 29.64 Lacs. (Rs. in Figures) : Time Alloved : 6 months i/c rainy season S.No SOR Item Particulers of Item Unit Rate Remarks 2 2.4 2.4.1 beyond 30 cm girth up to and including 60 cm girth each 350.0 2.4.2 beyond 60 cm girth up to and including 120 cm girth each 1150.0 2.4.3 beyond 120 cm girth up to and including 240 cm girth each 3500.0 2.4.4 above 240 cm girth each 6300.0 3 2.7 2.7.1 Ordinary rock cum 287.0 2.7.2 Hard rock (requiring blasting) cum 519.0 2.7.3 Hard rock (blasting prohibited) cum 828.0 4 2.25 2.25.1 All kinds of soil. cum 30.0 2.25.2 Ordinary or hard rock. cum 53.0 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete cum 672.0 Note: - Maximum thickness of this layer shall be 20 cm. 5 2.27 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) cum 393.0 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm cum 331.0 6 2.28 2.28.1 All kinds of soil. each 42.0 2.28.2 Ordinary rock each 68.0 2.28.3 Hard rock (requiring blasting) each 138.0 2.28.4 Hard rock (blasting prohibited) each 151.0 7 2.3 2.30.1 Along external wall where the apron is not provided using chemical emulsion@ 7.5 liters / sqm of the vertical surfaceof the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 36.0 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 42.0 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. sqm 199.0 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 50.0 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litresper hole by drilling 6 mm dia holes at downward angle of 45 degree at 150mm centre to centre and sealing the same. metre 201.0 8 2.41 2.42.1 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. cum 331.0 9 4.1 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete cum 6338.0 4.1.1.2 M-20 – Grade concrete cum 4933.0 4.1.1.3 M-15 – Grade concrete cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) cum 3890.0 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate cum 3474.0 4.1.3 With fly ash. Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 10 4.2 string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete Cum 6582.0 4.2.1.2 M 20 – Grade concrete Cum 5177.0 4.2.1.3 M 15 – Grade concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate Cum 4134.0 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate cum 4052.0 11 4.3 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. Sqm 169.0 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. sqm 267.0 4.3.3 Above plinth: Columns, pillars, posts and struts. Sqm 356.0 12 4.6 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) cum 5558.0 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. cum 4515.0 4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). Sqm 200.0 13 5.1 5.1.1 M-20 Grade Concrete cum 6153.0 5.1.2 M-15 Grade Concrete cum 5397.0 14 5.2 5.2.1 M-20 Grade Concrete cum 6231.0 15 5.3 5.3.1 M-20 Grade Concrete cum 6541.0 16 5.4 5.4.1 M-20 Grade Concrete cum 5542.0 17 5.5 5.5.1 M-20 Grade Concrete cum 6906.0 18 5.6.1 5.6.1 M-20 Grade Concrete cum 6337.0 19 5.7.1 5.7.1 M-20 Grade Concrete cum 5448.0 20 5.9.1 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level sqm 190.6 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. sqm 219.0 5.9.2.2 Above plinth upto 3.6 m height from plinth level sqm 330.0 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. sqm 40.0 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 439.6 5.9.4 Shelves(Cast in situ) sqm 290.0 5.9.5 Lintels, beams, girders, bressumers and cantilevers sqm 356.0 5.9.6 Columns, P i l l a r s , Piers, Abutments, sqm 471.2 Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. sqm 435.7 5.9.8 Spiral staircases (including landing). sqm 450.0 5.9.9 Arches, domes,vaults upto 6m span sqm 1141.6 5.9.10 Extra for arches, domes, vaults exceeding 6 m span sqm 451.3 5.9.11 Chimneys and shafts sqm 294.0 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. sqm 1481.0 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). sqm 0.2 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. sqm 191.0 5.9.17 Cornices and mouldings sqm 565.0 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. sqm 529.6 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. sqm 534.2 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 575.35 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 521.2 21 5.1 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). sqm 212.0 22 5.12 5.12.1 50 mm thick sqm 790.0 5.12.2 40 mm thick sqm 689.0 5.12.3 25 mm thick sqm 598.0 23 5.16 5.16.1 Mild steel and Medium Tensile steel bars. kg 78 .00 5.16.2 Hard drawn steel wire kg 75.0 5.16.3 Cold twisted bars (CTD) kg 81.0 5.16.4 Hot rolled deformed bars kg 81.0 5.16.5 Hard drawn steel wire fabric kg 76.0 5.16.6 Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 kg 80.0 5.16.7 Thermo-Mechanically Treated bars. FE 500 conforming .to IS 1786 kg 77.0 5.16.8 Corrosion resistance Steel bar Grade Fe-500 D & above , use with prior permission of C.E. Kg 98.0 24 5.22 5. 22.1 12 mm thick sqm 402.0 5. 22.2 25 mm thick sqm 574.0 5. 22.3 50 mm thick sqm 674.0 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. RM 102.0 5. 23.1.2 200mm wide. RM 137.0 5. 23.1.3 250mm wide. RM 153.0 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. RM 483.0 5. 23.2.2 200 mm wide. RM 646.0 5. 23.2.3 250 mm wide. RM 725.0 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. RM 367.0 5. 23.3.2 200 mm wide. RM 443.0 5. 23.3.3 250 mm wide. RM 555.0 25 5.24 5.24.1 Preparation of grooves RM 18.5 5.24.2 Preparation of Drip course RM 30.0 26 5.32 5.32.1 Non pigmented wet curing compound sqm 93.0 5.32.2 Pigmented wet curing compound. sqm 100.0 27 6.1 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5818.0 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5626.0 28 6.2 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 6012.0 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5821.0 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not lessthan 40kg /cm2 and water absorptionnot more than 15% in foundation and plinth i/c curing etc. complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5252.0 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5061.0 29 6.4 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5446.0 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5255.0 30 6.5 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4347.0 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). cum 4155.0 31 6.6 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4541.0 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) cum 4350.0 32 6.7 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5384.0 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5162.0 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5271.0 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5049.0 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5158.0 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4936.0 33 6.8 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5287.0 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5095.0 34 6.9 Cement Mortar 1:4 ( 1 cement : 4 sand) 35 6.12 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 697.0 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 673.0 36 6.13 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 639.0 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 615.0 37 6.14 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 546.0 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 522.0 38 6.15 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 570.0 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 551.0 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 524.0 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 505.0 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 479.0 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 459.0 39 6.37 6.37.1 Having100 kg / cm2 average compressive strength. 6.37.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5115.0 6.37.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4904.0 6.37.2 Having75 kg / cm2 average compressive strength. 6.37.2.1 Cement mortar 1:4 (1 cement : 4sand) cum 5007.0 6.37.2.2 Cement mortar 1:6 (1 cement : 6sand) cum 4797.0 6.37.3 Having50 kg / cm2 averagecompressive strength. 6.37.3.1 Cement mortar 1:4 (1 cement : 4sand) cum 4900.0 6.37.3.2 Cement mortar 1:6 (1 cement : 6sand) cum 4689.0 40 9.3 9.3.1 Sal wood cum 76229.0 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. cum 77538.0 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 64833.0 41 9.4 9.4.1 Second class teak wood cum 9062.0 9.4.2 Sal wood cum 7131.0 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. cum 7275.0 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 6030.0 9.5.4.1 35 mm thick sqm 1089.0 9.5.4.2 30 mm thick sqm 969.0 42 9.6 9.6.1 Second class teak wood sqm 2215.0 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood sqm 1763.0 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. sqm 971.0 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. sqm 1439.0 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type sqm 1369.0 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. sqm 1861.0 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type sqm 1650.0 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. sqm 791.0 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. sqm 1087.0 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. sqm 1333.0 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. sqm 1390.0 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick sqm 1298.0 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) sqm 973.0 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) sqm 1046.0 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading sqm 1532.0 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum sqm 580.0 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum sqm 754.0 43 9.14 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. Sqm 170.0 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. Sqm 53.0 44 9.15 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2736.0 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2753.0 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2815.0 9.15.2.2 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2759.0 45 9.16 9.16.1 12 mm thick Sqm 555.0 9.16.2 18 mm thick Sqm 654.0 46 9.17 9.17.1 18 mm thick Sqm 1270.0 9.17.2 25 mm thick Sqm 1383.0 47 9.18 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2823.0 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2648.0 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. Sqm 2465.0 48 9.19 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1870.0 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1696.0 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 1623.0 49 9.2 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). Sqm 401.0 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 50 9.25 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. Sqm 3174.0 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2599.0 9.25.1.3 Kiln seasoned selected class of sheesham wood. Sqm 2452.0 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. Sqm 3291.0 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2716.0 9.25.2.3 Kiln seasoned selected class of sheesham wood. Sqm 2569.0 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. Sqm 2797.0 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2306.0 9.25.3.3 Kiln seasoned selected class of sheesham wood. Sqm 2179.0 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. Sqm 2914.0 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2423.0 9.25.4.3 Kiln seasoned selected class of sheesham wood. Sqm 2296.0 9.26.2 30 mm thick shutters Sqm 2102.0 51 9.57 9.57.1 300x16 mm Each 170.0 9.57.2 250x16 mm Each 157.0 52 9.58 9.58.1 250x10 mm Each 68.0 9.58.2 200x10 mm Each 60.0 9.58.3 150x10 mm Each 42.0 9.58.4 100x10 mm Each 35.0 53 9.6 9.60.1 300x20x6 mm Each 72.0 9.60.2 250x20x6 mm Each 67.0 54 9.61 9.61.1 125 mm Each 27.0 9.61.2 100 mm Each 25.0 9.61.3 75 mm Each 24.0 55 9.62 9.62.1 150 mm Each 23.0 9.62.2 115 mm Each 20.0 9.62.3 90 mm Each 17.0 56 9.63 9.63.1 300 mm weighing not less than 200 gms. Each 40.0 9.63.2 250 mm weighing not less than 150 gms. Each 34.0 9.63.3 200 mm weighing not less than 120 gms. Each 28.0 57 9.65 9.65.1 300x16 mm Each 389.0 9.65.2 250x16 mm Each 326.0 9.65.3 400x16mm Each 601.0 58 9.66 9.66.1 250x10 mm Each 148.0 9.66.2 200x10 mm Each 93.0 9.66.3 150x10 mm Each 71.0 9.66.4 100x10 mm Each 50.0 59 9.68 9.68.1 300x20x6 mm Each 211.0 9.68.2 250x20x6 mm Each 173.0 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : Each 9.69.1 125 mm Each 60.0 9.69.2 100 mm Each 54.0 9.69.3 75 mm Each 48.0 60 9.7 9.70.1 150 mm each 37.0 9.70.2 115 mm each 33.0 9.70.3 90 mm each 26.0 61 9.73 9.73.1 125x64x1.90 mm each 67.0 9.73.2 100X58X1.90 mm each 59.0 9.73.3 75x47x1.80 mm each 39.0 9.73.4 50x37x1.50 mm each 25.0 62 9.74 9.74.1 125x64x2.50 mm each 76.0 9.74.2 100x60x2.50 mm each 60.0 9.74.3 75x50x2.50 mm each 46.0 63 9.76 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) each 456.0 9.77.2 125x70x4 mm (ordinary type) each 148.0 9.77.3 100x85x5.5 mm (heavy type) each 387.0 9.77.4 100x70x4 mm (ordinary type) each 117.0 9.77.5 75x65x4 mm (heavy type) each 145.0 9.77.6 75x40x2.5 mm (ordinary type) each 74.0 9.77.7 50x40x2.5 mm (ordinary type) each 32.0 64 9.78 9.78.1 150x125x27x5 mm each 385.0 9.78.2 125x125x27x5 mm each 345.0 9.78.3 100x125x27x5 mm each 304.0 9.78.4 75x100x20x3.2 mm each 239.0 65 9.79 9.79.1 400x10 mm each 400.0 9.79.2 250x10 mm each 329.0 9.79.3 200x10 mm each 261.0 9.79.4 150x10 mm each 221.0 9.79.5 100x10 mm each 142.0 66 9.8 9.80.1 300x16x5 mm each 237.0 9.80.2 250x16x5 mm each 225.0 67 9.81 9.81.1 125 mm each 205.0 9.81.2 100 mm each 181.0 9.81.3 75 mm each 141.0 68 9.82 9.82.1 300x16mm each 407.0 9.82.2 250x16mm each 374.0 69 9.87 9.87.1 40 mm each 144.0 9.87.2 50 mm each 150.0 9.87.3 65 mm each 162.0 9.87.4 75 mm each 185.0 70 9.99 9.99.1 Size 40 mm each 144.0 9.99.2 Size 50 mm each 156.0 9.99.3 Size 65 mm each 167.0 9.99.4 Size 75 mm each 196.0 71 9.101 9.101.1 300x16mm each 268.0 9.101.2 250x16mm each 245.0 72 9.102 9.102.1 400X10mm each 260.0 9.102.2 300x10mm each 198.0 9.102.3 250x10mm each 164.0 9.102.4 200x10 mm each 113.0 9.102.5 150x10 mm each 91.0 9.102.6 100x10 mm each 73.0 73 9.103 9.103.1 300x16x5mm each 255.0 9.103.2 250x16x5mm each 243.0 74 9.108 9.108.1 125x75x4 mm each 115.0 9.108.2 125x63x4 mm each 108.0 9.108.3 100x75x4 mm each 95.0 9.108.4 100x63x4 mm each 93.0 9.108.5 100x63x3.2 mm each 90.0 9.108.6 75x63x4 mm each 77.0 9.108.7 75x63x3.2 mm each 75.0 9.108.8 75x45x3.2 mm each 67.0 75 9.109 9.109.1 300x16 mm each 241.0 9.109.2 250x16 mm each 195.0 76 9.11 9.110.1 400X10mm each 123.0 9.110.2 300x10 mm each 114.0 9.110.3 250x10 mm each 102.0 9.110.4 200x10 mm each 82.0 9.110.5 150x10 mm each 69.0 9.110.6 100x10 mm each 55.0 77 9.111 78 9.113 9.113.1 125 mm each 75.0 9.113.2 100 mm each 55.0 9.113.3 75 mm each 46.0 79 9.114 9.114.1 Single rubber stopper each 35.0 9.114.2 Twin rubber stopper each 86.0 80 9.116 81 9.117 82 9.126 83 9.127 84 9.128 85 9.129 9.129.1 Triple strip vertical type. each 28.0 9.129.2 Double strip (horizontal type). each 23.0 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long each set 209.0 9.131.2 450mm long each set 256.0 9.131.3 500mm long each set 302.0 86 9.132 87 9.133 9.133.1 Marine plywood conforming to IS: 710 sqm 1591.0 9.133.2 Fire retardant plywood conforming to IS: 5509. sqm 1660.0 88 9.134.1 9.134.1 1.5 mm thick. sqm 851.0 89 9.134.2 90 9.138 9.138.1 12 mm thick. sqm 919.0 9.138.2 18 mm thick. sqm 1161.0 9.138.3 25 mm thick. sqm 1230.0 91 9.139 92 9.14 9.140.1 18 mm thick sqm 1493.0 9.140.2 25 mm thick sqm 2017.0 93 9.145 9.145.1 Board 12 mm thick sqm 811.0 9.145.2 Board 18 mm thick sqm 943.0 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick sqm 1055.0 9.146.2 25 mm thick sqm 1420.0 94 9.147 95 9.148 96 9.15 9.150.1 12 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1210.0 9.150.2 18 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1320.0 97 9.158 9.158.1 Extruded section Profile size 48x40 mm. metre 203.0 9.158.2 Extruded section Profile size 42x50 mm. metre 208.0 98 9.165 99 9.166 9.166.1 Plain PVC door shutters. sqm 2026.0 9.166.2 Pre laminated PVC door shutters. sqm 2490.0 100 9.167 101 9.168 as panel. The styles andrails will be mitred cut and joint with the help of PVC solvent cement and self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mmand 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. sqm 2026.0 9.168.2 Decorative finish (both side wood grained finish). sqm 2432.0 102 9.169 9.169.1 Single rebate (75 mm X 50 mm) RM 459.0 9.169.2 Single rebate (100 mm X50 mm) RM 720.0 9.169.3 Single or double rebate (125 mm X 65 mm) RM 923.0 103 9.17 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 2250.0 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3250.0 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3693.0 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 4135.0 104 9.186 105 9.187 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) metre 422.0 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) metre 403.0 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) metre 434.0 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) metre 99.0 9.187.1.5 Glazing bead (12mm x 18mm) metre 130.0 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) metre 519.0 9.187.2.3 Casement Glazing bead (35mm x 18 mm) metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) metre 9.187.3.2 Sliding window Sash (60mm x 44mm) metre 529.0 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) metre 139.0 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) metre 539.0 9.187.4.2 Sliding Door Sash (80mm x 44mm) metre 653.0 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) metre 139.0 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 106 9.188 9.188.1 200 x 19 x 1.9 mm each 321.0 9.188.2 250 x 19 x 1.9 mm each 369.0 9.188.3 300 x 19 x 1.9 mm each 462.0 9.188.4 350 x 19 x 1.9 mm each 526.0 9.188.5 400 x 19 x 1.9 mm each 636.0 107 9.189 108 9.191 109 9.192 110 9.193 111 9.194 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) sqm 6798.0 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). sqm 6221.0 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). sqm 4842.0 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) sqm 6681.0 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) sqm 6942.0 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion67 x 80 all having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) sqm 5290.0 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (ifrequired) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 4860.0 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made fromroll forming process of required length(shape & size according to UPVC profile),UPVC 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). sqm 7085.0 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±.0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). sqm 7063.0 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 5060.0 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). sqm 6880.0 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). sqm 5134.0 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area ofwindow above 1.75 sqm). sqm 6371.0 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) sqm 5913.0 112 9.198 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto sqm 4332.0 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). sqm 3532.0 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in- built roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension UPVC extruded glazing beads, UPVC extruded interlock and UPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 10.00 sqm). sqm 3676.0 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 8.00 sqm upto10.00 sqm). sqm 3810.0 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) sqm 4361.0 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 5.00 sqm) sqm 5617.0 9.2 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture.M.S. frame sqm 3908.0 113 9.201 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter sqm 2250.0 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter sqm 3229.0 114 9.202 9.202.1 1mm thick laminated sheet sqm 3693.0 9.202.2 0.12 mm thick laminated sheet sqm 3461.0 115 9.255 9.255.1 9 mm thick BWP grade commercial Sqm 841.0 plywood 9.255.2 12 mm thick BWP grade commercial Sqm 1064.0 plywood 9.255.3 18 mm thick BWP grade commercial Sqm 1169.0 plywood 9.255.4 25 mm thick BWP grade commercial Sqm 1366.0 plywood 116 9.256 9.256.1 25 mm outer dia & 300 mm long Each Set 984.0 9.256.2 32 mm outer dia & 450 mm long Each Set 1716.0 9.256.3 32 mm outer dia & 600 mm long Each Set 2041.0 117 9.257 9.196, 9.197, 9.198, 9.199) 118 9.258 9.258.1 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1040.0 119 10.7 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. sqm 747.0 10.7.2 Exceeding 16.80 sqm in area. sqm 782.0 120 10.11 10.11.1 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). kg 77.0 121 10.12 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. meter 402.0 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 394.0 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. meter 431.0 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 424.0 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. meter 472.0 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 464.0 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. meter 356.0 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 348.0 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. meter 385.0 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 377.0 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. meter 414.0 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 406.0 122 10.14 10.14.1 Hot finished welded type tubes kg 117.0 10.14.2 Hot finished seamless type tubes kg 123.0 10.14.3 Electric resistance or induction butt welded tubes. kg 142.0 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats ofEpoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. kg 132.0 123 10.17 124 10.18 125 10.19 126 10.21 127 10.22 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. kg 101.0 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 105.0 128 10.23 10.23.1 M.S. tube. kg 117.0 10.23.2 E.R.W. tubes. kg 132.0 129 10.25 130 10.26 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides sqm 646.0 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1334.0 131 10.27 10.27.1 With 4.0 mm thick glass panes sqm 792.0 10.27.2 With 5.50 mm thick glass panes sqm 873.0 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. sqm 916.0 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm boxbeading. sqm 611.0 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. sqm 936.0 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 750.0 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 800.0 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 872.0 132 10.28 10.28.1 With 4.0 mm thick glass panes. sqm 259.0 10.28.2 With 5.5 mm thick glass panes. sqm 262.0 133 10.29 134 11.19 11.19.1 Makrana white second quality. sqm 3051.0 11.19.2 Raj Nagar plain. sqm 1381.0 11.19.3 Agaria White/Morgarh sqm 1882.0 11.19.4 Katni marble sqm 1555.0 11.19.5 Black Zebra. sqm 1315.0 11.19.6 Udaipur / Baroda green marble sqm 1649.0 11.19.7 Pink plain marble. sqm 1448.0 11.19.8 Jaisalmer Yellow sqm 1582.0 135 11.2 11.20.1 Makrana white second quality. sqm 3675.0 11.20.2 Raj Nagar plain. sqm 1932.0 11.20.3 Agaria White/Morgarh sqm 2455.0 11.20.4 Katni marble sqm 2113.0 11.20.5 Black Zebra. sqm 1863.0 11.20.6 Udaipur / Baroda green marble sqm 2211.0 11.20.7 Pink plain marble. sqm 2002.0 11.20.8 Jaisalmer Yellow sqm 2141.0 136 11.21 11.21.1 Makrana white second quality. sqm 3773.0 11.21.2 Raj Nagar plain. sqm 2737.0 11.21.3 Agaria White/Morgarh sqm 2553.0 11.21.4 Katni marble sqm 2219.0 11.21.5 Black Zebra. sqm 1961.0 11.21.6 Udaipur / Baroda green marble sqm 2309.0 11.21.7 Pink plain marble. sqm 2100.0 11.21.8 Jaisalmer Yellow sqm 2240.0 137 11.22 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black sqm 1797.0 11.22.2 Granite fine grained dark crystal of other colours and various patterns sqm 2356.0 11.22.3 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns Sqm 2113.0 11.22.4 Granite grey/pink/brown with various patterns Sqm 1808.0 11.22.5 Cuddpah stone sqm 1279.0 138 11.23 139 11.24 140 11.25 141 11.29 11.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2919.0 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2675.0 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2370.0 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2705.0 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2486.0 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2212.0 142 11.3 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2642.0 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2422.0 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2153.0 11.30.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2455.0 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2258.0 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2011.0 patterns 143 11.32 144 11.33 11.33.1 Flamed Finish Granite sqm 2542.0 11.33.2 Leather Finish Granite sqm 2809.0 145 11.34 146 11.36 Note: - Deduction shall be made for not mirror polishing according to item no 11.43 147 11.37 148 11.38 11.38.1 10-12 mm thick sqm 1177.0 11.38.2 20 mm thick sqm 1231.0 149 11.39 150 11.4 11.40.1 Marble work meter 164.0 11.40.2 Granite work. meter 269.0 151 11.41 152 11.42 153 11.43 154 11.44 11.44.1 Red sand stone sqm 578.0 11.44.2 White sand stone sqm 578.0 11.44.3 Grey lime stone sqm 578.0 11.44.4 Kota stone sqm 678.0 155 11.47 156 11.48 157 11.49 158 11.52 159 11.53 160 11.54 161 11.55 162 11.56 163 12.63 11.63.1 Fastener with threaded dia 6 mm. each 25.0 11.63.2 Fastener with threaded dia 10 mm. each 29.0 11.63.3 Fastener with threaded dia 12 mm. each 46.0 164 11.66 165 11.72 proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver blocks as per required sizeand pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade sqm 805.0 11.72.2 60 mm thick C.C. paver block of M-35 grade sqm 680.0 11.72.3 60 mm thick C.C. paver block of M-30 grade sqm 605.0 166 11.75 including fixing of granite stone door frame with epoxy resin based adhesive including secured to the backing by means of cramps, drilling of hole with rawl plugs and screws 75mm long cleaning etc. complete. Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. metre 1010.0 11.75.2 Granite Door frame for 200mm thick wall Thickness. metre 1512.0 167 11.76 11.76.1 Plain ivory light shade sqm 950.0 Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) sqm 1033.0 Size 600X600mm thickness 9-10mm 168 11.77 11. 77.1 Plain ivory light shade sqm 940.0 Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) sqm 1022.0 Size 600X600mm thickness 9-10mm 169 11.8 11.80.1 In light colour and shades as ivory, beige blanco, grey etc. 11.80.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 934.0 11.80.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1206.0 11.80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1349.0 11.80.2 In dark colour and shade etc. 11.80.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 946.0 11.80.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1340.0 11.80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1546.0 170 11.81 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 923.0 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1196.0 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 935.0 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1329.0 171 11.82 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm sqm 1140.0 11. 82.1.2 Size 800X800mm thickness 9-10 mm sqm 1261.0 11. 82.1.3 Size 800X1600mm thickness 9-10 mm sqm 1489.0 11. 82.1.4 Size 1000X1000mm thickness 9-10 mm sqm 1388.0 11. 82.1.5 Size 600X1200 mm thickness 9-10 mm sqm 1235.0 11. 82.1.6 Size 800X1200 mm thickness 9-10 mm sqm 1450.0 11. 82.1.7 Size 1200X1200 mm thickness 9-10 mm sqm 1596.0 11. 82.1.8 Size 1200X1800mm thickness 9-10 mm sqm 1715.0 11. 82.1.9 Size 1200X2400 mm thickness 9-10 mm sqm 2403.0 172 11.83 11. 83.1 For skirting, riser, dado and wall lining etc.glossy/ rustic /stain/mattfinished in all colours and shades 11. 83.1.1 Size 300X600 mm thickness 9-10 mm sqm 1048.0 11. 83.1.2 Size 600X600 mm thickness 9-10 mm sqm 1129.0 11. 83.1.3 Size 800X800mm thickness 11-12mm sqm 1250.0 11. 83.1.4 Size 600X1200 mm thickness 11-12mm sqm 1224.0 11. 83.1.5 Size 800X1200 mm thickness 11-12mm sqm 1440.0 173 11.84 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 2296.0 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 2113.0 11. 84.1.3 Gray/Pink/Brown with various patterns sqm 1879.0 174 11.85 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 1775.0 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 1610.0 11. 85.1.3 Gray/Pink/Brown with various patterns sqm 1404.0 175 11.97 Size 800X1600 mm thickness 8-9 mm Sqm 1778.0 176 11.102 177 11.103 178 12.4 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² meter 500.0 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² meter 431.0 179 12.7 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² meter 459.0 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² meter 402.0 180 12.12 12.12.1 Corrugated serrated adjustable ridges meter 367.0 12.12.2 Plain wing adjustable ridges meter 311.0 12.12.3 Close fitting adjustable ridges meter 420.0 12.12.4 Unserrated adjustable hips meter 506.0 181 12.13 12.13.1 Corrugated apron pieces meter 340.0 12.13.2 Eaves filler pieces meter 232.0 12.13.3 North light curves meter 500.0 12.13.4 ventilator curves meter 622.0 12.13.5 Barge boards meter 623.0 12.13.6 Ridge finials pair 229.0 12.13.7 Special north light curves each 753.0 12.13.8 S type louvers meter 418.0 182 12.14 183 12.15 primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 12.16 12.16.1 Ridges plain (500 - 600mm). meter 320.0 12.16.2 Flashings/ Aprons.( Upto 600 mm) meter 284.0 12.16.3 North light curves. meter 341.0 12.16.4 Barge board (Upto 300 mm) meter 274.0 12.16.5 Crimp curve sqm 315.0 12.16.6 Gutter. (600 mm over all girth) meter 781.0 185 12.17 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. sqm 1031.0 12.17.2 2mm thick flat. sqm 955.0 186 12.23 187 12.24 188 12.26 189 12.27 190 12.32 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) metre 136.0 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) metre 238.0 191 12.33 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) each 67.0 12.33.1.2 110 mm (minimum wall thickness 2.2mm) each 102.0 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) each 121.0 12.33.2.2 110 mm (minimum wall thickness 2.2mm) each 94.0 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) each 176.0 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) each 163.0 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) each 78.0 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) each 112.0 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) each 69.0 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) each 99.0 192 12.34 12.34.1 75 mm (minimum wall thickness 1.8mm) each 97.0 12.34.2 110 mm (minimum wall thickness 2.2mm) each 114.0 hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board. 12.58.1.1 Flat surfaces sqm 676.0 12.58.1.2 Curved surfaces sqm 748.0 12.58.1.3 Sunk or raised mouldings sqm 175.0 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. sqm per meter height 59.0 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I: 2011 (Board with BIS certification marks). sqm 750.0 12.58.2.2 Fire resistant Glass ReinforcedGypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) sqm 866.0 12.58.2.3 12.5mm thick moisture resistant gypsum plasterboards Moistbloc as per BS EN 520 confirming to water absorption class H1 with total water absorption < 5%, Green Pro certified by CII sqm 920.0 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturersspecification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. sqm 1277.0 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured throughautoclaving process. sqm 1150.0 193 13.1 13.1.1 1:4 (1 cement : 4 sand) sqm 173.0 13.1.2 1:6 (1 cement : 6 sand) sqm 160.0 194 13.2 13.2.1 1:4 (1 cement : 4 sand) sqm 184.0 13.2.2 1:6 (1 cement : 6 sand) sqm 168.0 195 13.3 13.3.1 1:4 (1 cement : 4 sand) sqm 245.0 13.3.2 1:6 (1 cement : 6 sand) sqm 225.0 196 13.4 13.4.1 1:3 (1 cement : 3 sand) sqm 210.0 13.4.2 1:4 (1 cement : 4 sand) sqm 203.0 197 13.5 13.5.1 1:3 (1 cement : 3 sand) sqm 236.0 13.5.2 1:4 (1 cement : 4 sand) sqm 220.0 198 13.13 199 13.14 200 13.15 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof sqm 34.0 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof sqm 22.0 201 13.16 13.16.1 In one coat sqm 11.0 13.16.2 In two coats sqm 18.0 202 13.17 13.17.1 In one coat sqm 158.0 13.17.2 In two coats sqm 260.0 203 13.18 13.18.1 Spherical ceiling sqm 42.0 13.18.2 Groined ceiling sqm 47.0 13.18.3 Flewing soffits sqm 28.0 204 13.38 205 13.39 13.39.1 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. sqm 130.0 13.39.2 Extra for making 12mm flute grove with 6 mm depth to prepare the surface even and smooth complete. metre 70.0 206 13.41 207 13.43 208 13.44 209 13.45 210 13.46 211 13.47 13.47.1 One coat. sqm 20.0 13.47.2 Two coats. sqm 32.0 212 13.48 13.48.1 One coat. sqm 37.0 13.48.2 Two coats. sqm 56.0 213 13.49 214 13.51 215 13.52 216 13.53 217 13.54 218 13.54.1 219 13.54.2 220 13.54.3 221 13.55 13.55.1 One coat sqm 63.0 13.55.2 Two coats sqm 101.0 222 13.64 223 13.65 224 13.66 13.66.1 One coat. sqm 35.0 13.66.2 Two coats. sqm 53.0 225 13.68 226 13.71 227 13.77 228 13.8 13.80.1 0.8-1.2mm thickness sqm 368.0 13.80.2 2.0-2.5mm thickness sqm 338.0 229 13.81 effective for 90 Days(03 Months) . 230 13.103 Note:- Applicable to item No. 13.1 to item No. 13.10 231 13.105 13.105.1 Standard pattern and design wallpaper Sqm 615.0 13.105.2 3D pattern and design wallpaper Sqm 750.0 13.105.3 Customize design wallpaper Sqm 1145.0 232 14.5 14.5.1 Float glass panes of thickness 4 mm sqm 679.0 14.5.2 Float glass panes of thickness 5.5 mm sqm 759.0 233 14.6 14.6.1 Float glass panes of thickness 4 mm sqm 801.0 14.6.2 Float glass panes of thickness 5.5 mm sqm 882.0 234 14.7 14.7.1 Float glass panes of thickness 4 mm sqm 697.0 14.7.2 Float glass panes of thickness 5.5 mm sqm 778.0 235 14.8 14.8.1 2nd class teak wood fillets meter 30.0 14.8.2 Haldu/Bija/Kail wood fillets. meter 26.0 236 14.11 237 14.24 238 14.27 239 14.28 240 14.29 241 14.31 242 14.36 243 14.37 244 14.38 245 14.39 246 14.48 247 14.49 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. sqm 42.0 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. sqm 30.0 248 14.51 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). sqm 87.0 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). sqm 52.0 249 14.52 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. sqm 65.0 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). sqm 41.0 250 14.53 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. sqm 58.0 251 14.62 14.62.1 (one or more coats) sqm 9.0 14.62.2 (two or more coats) sqm 11.0 252 15.2 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). cum 578.0 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). cum 356.0 253 15.6 15.6.1 In lime mortar with old mughal bricks. cum 421.0 15.6.2 In lime mortar. cum 202.0 15.6.3 In cement mortar. cum 487.0 254 15.7 15.7.1 From brick work in lime mortar. 1000 nos 1254.0 15.7.2 From brick work in cement mortar. 1000 nos 1560.0 255 15.8 15.8.1 In lime mortar. cum 275.0 15.8.2 In cement mortar. cum 582.0 256 15.13 257 15.14 15.14.1 Of area 3 sq. metres and below. each 85.0 15.14.2 Of area beyond 3 sq. metres. each 117.0 258 15.15 15.15.1 Of area 3 sq. metres and below. each 33.0 15.15.2 Of area beyond 3 sq. metres. each 44.0 259 15.47 260 15.48 261 15.49 262 15.51 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep each 611.0 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. each 1069.0 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. each 2023.0 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep each 1553.0 263 15.52 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. each 486.0 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. each 579.0 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). each 468.0 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). each 322.0 264 15.64 265 17.1 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. each 2995.0 266 17.2 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid. each 3036.0 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid. each 3013.0 267 17.3 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. each 4613.0 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. each 4590.0 268 17.11 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. each 2187.0 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tap. each 1938.0 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. each 1664.0 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. each 1775.0 269 17.12 270 17.14 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. each 8074.0 17.14.1.2 510x1040 mm bowl depth 225mm. each 7609.0 17.14.1.3 510x1040 mm bowl depth 200mm. each 7493.0 17.14.1.4 510x1040 mm bowl depth 178mm. each 5286.0 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. each 4583.0 17.14.2.2 610x460 mm bowl depth 200 mm. each 4351.0 17.14.2.3 470x420 mm bowl depth 178 mm. each 3422.0 271 17.22 17.22.1 White each 945.0 17.22.2 coloured each 1037.0 272 17.24 17.24.1 White each 456.0 17.24.2 Black each 433.0 17.24.3 Coloured (other than black and white) each 688.0 273 17.25 274 17.6 17.60.1 75 mm each 33.0 17.60.2 110 mm each 50.0 275 17.61 276 17.64 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia each 87.0 17.64.1.2 40 mm dia each 98.0 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia each 87.0 17.64.2.2 40 mm dia each 98.0 277 17.65 278 17.67 279 17.67 17.68.1 Circular shape 450mm dia. each 806.0 17.68.2 Rectangular shape 453x357mm each 642.0 17.68.3 Oval shape 450x350mm (outer dimensions) each 697.0 17.68.4 Rectangular shape 1500x450 mm each 1311.0 280 17.69 281 17.7 17.70.1 C.P. brass each 340.0 17.70.2 Vitreous china each 324.0 282 17.74 283 17.75 284 17.76 285 18.6 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia .Pipes metre 129.0 18.6.1.2 20 mm nominal outer dia .Pipes metre 153.0 18.6.1.3 25 mm nominal outer dia .Pipes metre 177.0 18.6.1.4 32 mm nominal outer dia .Pipes metre 254.0 18.6.1.5 40 mm nominal outer dia .Pipes metre 354.0 18.6.1.6 50 mm nominal outer dia .Pipes metre 528.0 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes metre 207.0 18.6.2.2 20 mm nominal outer dia .Pipes metre 234.0 18.6.2.3 25 mm nominal outer dia .Pipes metre 288.0 18.6.2.4 32 mm nominal outer dia .Pipes metre 360.0 286 18.7 External Work 18.7.1 15 mm nominal outer dia .Pipes metre 122.0 18.7.2 20 mm nominal outer dia .Pipes metre 141.0 18.7.3 25 mm nominal outer dia .Pipes metre 185.0 18.7.4 32 mm nominal outer dia .Pipes metre 238.0 18.7.5 40 mm nominal outer dia .Pipes metre 324.0 18.7.6 50 mm nominal outer dia .Pipes metre 498.0 18.7.7 62.50 mm nominal inner dia .Pipes. metre 1429.0 18.7.8 75 mm nominal inner dia .Pipes. metre 2018.0 18.7.9 100mm nominal inner dia .Pipes. metre 2791.0 18.7.10 150 mm nominal inner dia .Pipes. metre 3358.0 287 18.13 18.13.1 25 mm nominal bore each 428.0 18.13.2 32 mm nominal bore. each 500.0 18.13.3 40 mm nominal bore each 584.0 18.13.4 50 mm nominal bore each 749.0 288 18.14 18.14.1 15 mm nominal bore each 316.0 18.14.2 20 mm nominal bore each 431.0 18.14.3 25 mm nominal bore each 499.0 289 18.17 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore each 88.0 18.17.1.2 20 mm nominal bore each 129.0 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore each 149.0 18.17.2.2 20 mm nominal bore each 184.0 290 18.18 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. each 916.0 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. each 870.0 291 18.28 292 18.29 18.29.1 15 mm nominal bore each 306.0 18.29.2 20 mm nominal bore each 338.0 293 18.3 18.30.1 15 mm nominal bore each 318.0 18.30.2 20 mm nominal bore each 344.0 294 18.31 295 18.32 296 18.33 297 18.34 298 18.35 299 18.36 300 18.37 301 18.38 302 18.39 303 18.41 304 18.42 305 18.43 18.43.1 100 mm diameter each 806.0 18.43.2 150 mm diameter each 922.0 18.43.3 200 mm diameter each 1336.0 306 18.64 307 18.65 308 18.67 309 18.68 18.68.1 300 mm long each 450.0 18.68.2 600 mm long each 650.0 310 19.4 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) metre 234.0 19.4.2 160 mm diameter OD (min. wall thickness 4.0 mm) metre 477.0 19.4.3 200 mm diameter OD (min. wall thickness 4.9 mm) metre 751.0 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) metre 972.0 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) metre 1232.0 311 19.5 19.5.1 110 mm diameter PVC. pipe metre 576.0 19.5.2 160 mm diameter PVC. pipe metre 704.0 19.5.3 200 mm diameter PVC. pipe metre 821.0 19.5.4 250 mm diameter PVC. pipe metre 949.0 19.5.5 300 mm diameter PVC pipe metre 1078.0 312 19.6 19.6.1 110 mm diameter PVC. pipe metre 274.0 19.6.2 160 mm diameter PVC. pipe metre 444.0 19.6.3 200 mm diameter PVC. pipe metre 521.0 19.6.4 250 mm diameter PVC. Pipe metre 607.0 19.6.5 300 mm diameter PVC pipe metre 700.0 313 19.7 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks each 1764.0 19.7.1.2 With Sewer bricks conforming to IS : 4885 each 1668.0 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks each 1803.0 19.7.2.2 With sewer bricks conforming to IS : 4885 each 1707.0 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks each 1913.0 19.7.3.2 With Sewer bricks conforming to IS : 4885 each 1818.0 314 19.9 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks each 7997.0 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 7747.0 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight offrame 58 kg) : 19.9.2.1 With well burnt bricks each 18086.0 19.9.2.2 With Sewer bricks conforming to IS : 4885 each 17402.0 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) 19.9.3.1 With well burnt bricks each 21816.0 19.9.3.2 With Sewer bricks conforming to IS : 4885 each 21228.0 315 19.1 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks metre 6176.0 19.10.1.2 With Sewer bricks conforming to IS : 4885 metre 5448.0 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks metre 7380.0 19.10.2.2 With Sewer bricks conforming to IS : 4885 metre 6512.0 316 19.12 19.12.1 With well burnt bricks metre 5257.0 19.12.2 With Sewer bricks conforming IS : 4885 metre 4648.0 317 21.1 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 378.0 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 416.0 21.1.1.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 426.0 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 446.0 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 484.0 21.1.2.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 494.0 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. kg 80.0 318 21.2 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. sqm 802.0 21.2.2 Pre-laminated particle board with decorative lamination on both sides. sqm 907.0 319 21.3 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) sqm 774.0 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than sqm 948.0 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). sqm 1182.0 320 21.5 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness each 1890.0 21.5.2 With brass cover plate - minimum 1.25 mm thickness. each 2072.0 321 21.16 21.16.1 Anodized (AC15 ) aluminium each 62.0 21.16.2 Powder coated minimum thickness 50 micron aluminium each 65.0 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. each 69.0 322 21.17 323 21.18 324 21.19 325 21.21 326 21.22 327 21.23 328 21.24 329 21.32 330 22.6 a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 331 22.14 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cum 6569.0 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) cum 9308.0 22.14.3 Cement mortar 1:4 (1cement : 4 sand) cum 8437.0 332 25.1 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) each 4726.0 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410X515X255 mm with integral foot rests.(Premium Range) each 4392.0 333 25.2 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan Size 360X545X395 with solid poly propelyne made soft closing seat cover (Premium Range) each 9788.0 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360X475X395 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 8742.0 334 25.3 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380X520X375 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 26412.0 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390X570X365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 23559.0 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 21099.0 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) each 18838.0 335 25.4 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420X710X810mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 28103.0 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380X610X805mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 19275.0 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18952.0 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375X650X800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18023.0 336 25.5 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) Each 34317.0 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 25954.0 25.5.3 Anti germ Fluoro-Polymer Coated Single PieceW.C. Pan Size 385X720X710mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 22237.0 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 19450.0 337 25.6 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 380X650X730mm with solid poly propelyne made soft closing seat cover (Premium Range) each 13365.0 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 375X360X750mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) each 10670.0 338 25.7 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595X435X185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) each 16581.0 339 25.8 25.8.1 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x415x200mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flance & spout complete (decol technology). (Premium Range) each 14543.0 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570X820X195mm with 15 mm C. P. Table Top pressmatic Pillar cock auto closing system (decol technology). (Premium Range) each 13614.0 340 25.9 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) each 15591.0 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) each 14940.0 341 25.1 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) each 18585.0 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) each 16785.0 342 25.11 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) each 14544.0 25.11.2 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal size 475X315X715 mm top inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) with 15mm Brass made Pressmatic auto closing open urinal flush valve with wall flange (Decol technology, 400000 operation warranted) complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : each 13336.0 25.11.3 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal back inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) Size 385X325X635 mm with Concealed sensotronic flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : URS-WHT-13253N & PRS-CHR-073 each 10641.0 343 25.12 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock. (Premium Range) each 23927.0 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) each 20025.0 344 25.13 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480 X 300X740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) each 18491.0 345 25.14 346 25.14.1 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor battery & electrical oprated type (9V transformer) for flushing. (Premium Range) each 22998.0 347 25.15 348 25.16 349 25.17 350 25.18 351 25.19 352 25.21 353 25.22 354 25.23 355 25.24 356 25.25 357 25.26 358 25.27 359 25.28 360 25.29 361 25.31 362 25.32 363 25.33 364 25.34 365 25.35 366 25.36 367 25.37 368 25.38 369 25.39 370 25.41 371 25.42 372 25.43 373 25.44 374 25.45 375 25.46 376 25.47 377 25.48 378 25.49 379 25.51 380 25.52 381 25.53 382 25.54 383 25.55 384 25.56 385 25.57 386 25.58 387 25.59 388 25.61 389 25.62 390 25.63 vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 14729.0 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) each 15100.0 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) each 18490.0 391 25.64 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 10617.0 Note- Schedule of items includes all the items required for maintainance of buildings regarding A/R, S/R MOW, Deposit & Other Works as per SCHEDULE OF RATES FOR BUILDING WORKS inforce from 01/01/2024, issued by Project Director, Public Works Department (PIU) M.P. Bhopal. Sub Engineer Sub Divisional OfficerSurvey Sub Division.P.W.D. Bhopal Executive EngineerMaintanance Division No.2P.W.D. Bhopal
Contract Date: Apr 23, 2026 Contract Value : 21.93 Lakh
Government Departments No of Bidders 5
Madhya Pradesh View Result →
41.
Defence #11306500 AOC
Tender for Taking Down Cement Plaster On Brick, Concrete Stone Surfaces Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc. Complete All As Specified And Directed , M & L 10 Mm Thick Rendering On Cement Mortar 1:6 On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed , Material And Labour For 10Mm Thick Rendering In Cement Mortar (1:3) On Brick Or Concrete Surfaces Of Ceiling Finshed Even And Smooth Without Using Extra Cement. Complete All As Specified And Directed , M & L For 15Mm Thick Rendering In Cement Mortar 1:4 On Brick , Concrete And Roof Surface With Wpc @ 200Ml Per 50Kg By Weight Of Cement Finishing The Surfaces Even & Fair, Complete All As Directed.(Wpc Will Be Measured And Paid Separately). , Supply Only Liquid Water Proofing Compound. , Material And Labour For Complete Removal Of Existing Treatment For Old Wall Surface, Including Washing Down And Stopping Of Distempered Surfaces And Applying Two Coat Of Distempered Oil Emulsion Over 1Mm Thick Wall Care Putty All As Specified And Directed. , Material And Labour For 1 Mm Thick Wall Care Putty On Wall All As Specified And Directed. , Material And Labour For Preparation Of Old Painted Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint All As Specified And Directed. , Material And Labour For Preparation Of Old Previously Treated Plastered Surface Of Ceilings Including Cornices Etc, And Cleaning By Brooming Down And Applying Two Coat Of White Wash On Ceilig All As Specified And Directed. , Material And Labour For Preparation Of Old Distempered Surface Of Walls Including Washing Down And Stopping Of Distempered Surfaces And Applying One Coat Of Distempered Oil Emulsion All As Specified And Directed. , M & L For Preparation Of New External Plasterd Surface Of Wall And Ceiling Apply Of Birla White Putty, Make The Surface Smooth By Rubbing With Emary Paper And Applying Two Coats Of Weather Proof Paint Over A Coat Of Water Thinkable Cement Primer Complete All As Specified And Directed , M & L For Preparation Of Old Plasterd Surface Of Wall And Ceiling Apply Make The Surface Smooth By Rubbing With Emary Paper And Applying One Coats Of Weather Proof Paint Complete All As Specified And Directed , M & L For Preparing New Wooden Surfaces Of Any Description, Not Otherwise Described Over 10 Cm In Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer, Complete All As Specified And Directed. , M&L Preparing New Plastered Surfaces Of Wall And Applying Two Coats Of Acrylic Distemper/ Distemper Oil Emulsion (Obd), Over A Coat Of 1Mm Thick Wall Care Putty All As Specified Including Preperation Of Surfaces Complete All As Specified And Directed , M&L Preparing Newly Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash, Complete All As Specified And Directed. , M&L For Writing Letters Or Figureswith Synthetic Enamel Paint (Block. Roman, Italic Or Indian) N Exc. 30 Cm High,Complete All As Directed. , Dismantling Of Wall And Ceiling Boards Any Type And Thickness Including Cover Fillets, Complete All As Specified And Directed. , Supply And Fix 600Mmx600mmx4mm Thick ‘E Board Classic (Make-Everest Industries Ltd) As In False Ceiling Including Supply And Fixing Gi ‘Tee Grid Frame Work Made Of Special Section Of M.S Galvanized Sheet 0.30Mm Thick , Bottom Portion Painted With Cellular Nitro Painting, Warping The Suspending Wire Around The Existing Wooden/Steel Purlin /Rafter For Suspending Grid Frame Work Of Size 605Mmx605mm Suspended With 4 Mm Dia Gi Wire @ 1200Mm C/C On Main Tee And Fixed To T-Grid With The Help Of Level Clip Or As Per Manufacturer Direction. The Section Consisting Of Main Tee 37Mmx24mmx0.60Mm, Cross Runner Tee 37Mmx24mmx0.60Mm And Perimeter Angle Of 24Mmx24mmx0.50Mm Thick. Perimeter Angle To Be Fixed To Wall With Gi Screw Of 40Mm Long @ 450 Mm C/C Along The Perimeter Of Wall Including Applying Two Coats Of Distemper Oil Emulsion Complete All As Specified And Directed , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), And Rubbish Off From The Site, Complete All As Directed. , M&L For 25 Mm Thick Plain Cement Concrete 1:2:4 Type B1 (Using 20 Mm Graded Stone Aggregate) As In Sub Floor Finishing Cement Concrete Surface Even And Smooth Using Extra Cement Complete All As Specified And Directed , M&L For 15 Mm Thick Screed Bed In Cm 1:4 For Laying Floor Tiles, Complete All As Specified And Directed , M&L For Non-Skid Ceramic Coloured Tiles 7 To 8 Mm Thick (Square/Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding .18 Sqm, In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White/Coloured Cement To Match The Shade, Complete All As Specified And Directed. , M&L For Light Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Complete All As Specified And Directed. , M&L For Dark Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Complete All As Specified And Directed. , M&L For Light Shade Virified Ceramic Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, As In Skirting, Dados And Riser To Steps Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Complete All As Specified And Directed. , M & L For 10Mm Thick Rendering In Cm 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Rough To Receive Tiles . , M & L For 450X300x7mm Mm Thick Glazed Coloured Ceramic Tiles On Vertical Surface Of Wall Set And Jointed In Neat Cement Slurry And Pointed In White/Coloured Cement To Match The Shade. , Demolition Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc And Removal Of Rubbish From Site, Complete All As Specified And Directed.. , M&L18- 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Cooking Platforms In Cm 1:4 Including Pointing In White Cement 1:2 Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Including Moulding Of Edged,Complete All As Specified And Directed. , M&L For 20Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) For Wall Lining (Veneering To Wall) 12Mm Thick In Cement Mortar (1:3) And Pointing With White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Including Moulding Of Edges If Reqd, Complete All As Specified And Directed. , Demolition Of Precast Cement Concrete Articles And Precast Concrete Block Walling Built In Cement Mortar, Comlpete All As Directed , M&L For Precast Cement Concrete 1:3:6 Type C1 Using 20 Mm Graded Aggregate Block Solid Building Blocks Or Slabs In Not Exc 10Cm Thick (With Plain Or Interlocking Joints As Directed ) Complete Set In Cm 1:4 , Demolition Of Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For, Complete All As Directed. , M&L Mild Steel Tmt Bars 10 Mm Dia., And Over Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia., Or Securing With Clips. Complete All As Specified And Directed , Material And Labour For Form Work To Slabs, Chajja With Fair Finish Surfaces Complete All As Specified And Directed. , Material And Labour For Reinforced Cement Concrete Nominal Mix 1:2:4 (Using 20 Mm Graded Crushed Stone Aggregate) Type B1 In Cm 1:6 As In Chajjas, Slabs Work Including Removing Rubbish Off The Premises Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Exceeding 1.50 Sqm But Not Exc 4 Sqm, Complete All As Directed. , Taking Down Shutters Of Any Description Not Exc1.00 Sqm Each,Complete Al As Directed. , S & F Mild Steel Bands, Straps, Clamps, Hold Fasts, Wall Ties And Similar Articles Conforming To Fe-290-O, Complete All As Specified And Directed. , S & F 2Nd Class Hard Wood Plain Solid Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed , S&F 35 Mm Thick Second Class Hard Wood Plain Framed, Panelled Shutter (Two Panel) With Lock Rail And Panel Of 9 M Bwp Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rails And Stiles As Per Is 1003 ( Part I) Kiln Seasoned And Chemically Pressure Treated Complete All As Specified And Directed , S&F 30 Mm Thick Second Class Hard Wood Glazed And Skelton Shuters , Open Rebated And Prepared To Receive Galss , Gauze , Etc, Divided Into Squares, With Plain , Chamfered Or Rounded Fitted With Cut And Mitred And Rebated Shash Bars Any Numbers Beads For Securing Glass, Etc Sizes Of Members Of Shutters As Speified In Ssr Part I Section 8 , Clause 8.24, Complete All As Specified And Directed. , S&F 30Mm Flush Shutters, Solid Core Construction With Particle Board Core And Plywood Face Panels, Commercial Type On Both Side And Both Face Is Covered With Decorative Face Veneer With Lipping/Frame Tp Match All As Completed And Specified As Directed. , S & F For 18Mm Veneered Decorative Plywood, Grade 1 (With Bwr Resin) With Decorative Face Veneers On Both Faces; Fixed With Screws To Timber Frame Work As In Shutters For Kitchen Cabinate/Cupboard Shutters Etc Complete All As Specified And Directed, , S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying And Fixing In Opening As Per Specification And Drawing Complete All As Specified And Directed. , S & F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of Ms Tubes For Top & Bottom Rails. Ms Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail, Panelling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded/Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading And Joined Together With Solvent Cement Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed. , S & F 100Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S& F Aluminium Anodised Barrel Tower Bolts 150Mm Long Of Extruded Section And Fixed , S & F 150Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S&F Pre Coated Mild Steel Floor Door Stopper ,Tongue Anodized 140Mm Length Including Vulcanised Rubber Piece , Supply And Fix In Repair Toilet Paper Holder Supar Of Brass Chromium Plated Fitted To Wall With Cp/ Brass Screws Of Make - Sona (Code Al 1001 ) Complete All As Specified And Directed , S&F In Repair Harrison Rails( Curtain Rail), Mild Steel,Chromium Plated With Fixing Brackets,Stops,Rollers Etc, Complete All As Sspecified And Directed. , S & F Aluminium Alloy, Anodised, Sliding Door Bolts 250 Mm Size With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheets, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminium Alloy Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size Quality Or Description) From Metal Frame Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones. , S & F Sheet Glass 3Mm Thick Ordinary Quality And Glazing With Oil Putty/Glazing Clips/Beadings In Squares N Exc 0.50 Sqm In Each Pane. , S & F 3Mm Thick Figured Glass, Pin Head Glazing With Oil Putty/Glazing Clips/Beading In Squares N Exc 0.50 Sqm In Each Pane, Complete All As Specified And Directed. , S&F For 50Mm Dia, Polished, Hard Wood Knobs Fixed With Screws, Complete All As Specified And Directed. , S&F For Continuous (Piano) Hinges, Mild Steel, Bright Finish Or Electro Galvanised, 30 Mm Wide Flap (When Open), Complete All As Specified. , S&F In Repair For Continuous (Piano) Hinges, Mild Steel, Bright Finish Or Electro Galvanised, 30 Mm Wide Flap (When Open), Fixed In Repairs, Complete All As Specified. , Supply And Fixed In Repair 15Mm Angle Valves, Cast Copper Alloy Chromium Plated(Fancy Type), Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed, Complete All As Specified And Directed. , S & F 75Mm Size Mild Steel Butt Hinges Medium Weight Cold Rolled And Fixed. , S & F 100Mm Size Extruded Aluminium Alloy Handles, Fabricated Type Anodised , S&F For 100 Mm Size Hasp And Staple, Safety Type, Aluminium Anodized With Mild Steel Hinge Pin Including Bolt To Hinge Plate And Fixed With Screws, Complete All As Specified. , S & F In Repair Vitreous China Wash Down Water Closet Pan Of Pedestal Pattern, White With P Or S Traps, Including Connecting To Trap And To Flushing Pipe Etc Complete All As Specified. , Dismantling Of Pvc(Swr),In Any Position And In Any Description Pattern Including All Fittings Etc Complete All As Specified And Directed. , Supply And Fix In Repairs Pvc (Swr) Wc Connector 110Mm Dia With Lip Ring With Rubber Ring Joints Fixed To Walls Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall Complete All As Specified And Directed. , Supply And Fix 75Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Wall Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Bends Any Radius With Access Door Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Junction Single , (Single T) Equal Or Unequal With Access Door Complete All As Specified And Directed. , Supply And Fix 75Mm Bore Pvc (Swr) Bends Any Radius With Access Door Complete All As Specified And Directed. , Supply And Fix 110Mm Bore Pvc (Swr) Vent Cowl Complete All As Specified And Directed. , S&F In Rep Pvc (Swr) Floor Trap, 75Mm Dia Outlet, Plain With Grating Incl Jointing With Solvent Cement, Complete All As Specified And Directed. , Supply And Fix In Rep 15Mm Bore Galvanised Iron Tube, Medium Grade, With All New Fittings, Fixed To Walls And Ceiling Or Laid In Floor Complete All As Specified And Directed. , Supply And Fix In Rep 20Mm Bore Galvanised Iron Tube, Medium Grade, With All New Fittings, Fixed To Walls And Ceiling Or Laid In Floor Complete All As Specified And Directed. , S&F In Repair 15Mm Brass Cp Wall Mixer For Mixing Hot And Cold Water Screwed Down For Iron Pipe And Fixed In Bath Shower,Wash Basin & Kichen Sink With Complete All As Specified And Directed. , Supply And Fix In Repairs Plate Rack Made Of Stainless Steel 0.50Mm Thick,Over All Size 762Mm(H)X787mm(W)X254mm(D) Complete All As Specified And Directed. , S & F In Repairs Chromium Plated Fancy Type 15Mm Dia Stop Cock, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specifed. , S & F In Repairs Chromium Plated Fancy Type 15Mm Dia Bib Tap, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specifed. , S & F In Repairs Chromium Plated Fancy Type Pillar Taps 15Mm Dia Cast Copper Alloy With Capstan Heads, Screwed Down High Pressure, With Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe And Fixed, Complete All As Specified And Directed , S&F In Repairs Vitreous China Wash Hand Basin White Flat Back Of Size 550Mmx400 Mm Including Cutting For And Pinning In End Of Brackets,32 Mm Waste Fittings,Brass Chromium Plated For Glazed Ware Sinks,Basins Etc.With Long Screwed Shanks And Fly Nuts Flange End Bedded In Red Lead Cement And Other End Fixed.And Flush Pipe Of Polytethylene Of Low Or High Density Or Pvc 32 Mm Dia Complete All As Specified And Directed , S & F In Repairs 10 Ltrs Capacity Pvc Valveless Syphonic Action Type Flushing Cistern Low Level White With Inlet Ball Valve, Float, Chain And Pull And Brackets Etc Complete All As Specified And Directed , S & F In Repair Pvc Connection 15Mm Dia 450 Mm Long With Brass Check Nuts And Washers Complete All As Specified And Directed , S & F In Repair Plastic Water Closet Seat Cover, White Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And Directed , S&F In Repair For Health Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified , S&F In Repair Cp Towel Ring Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 90 Gms) , S&F In Repair Soap Dish, Any Type, Fiexd To Plugs With Chromium Plated Brass Screws Complete All As Specified And Directed , S&F In Repair Cp Towel Rail 450Mm Long Of Ptmt Fixed With Chromium Plated Brass Screws (Min Wt 190 Gms) Complete All As Specified And Directed , Supply And Fix In Repairs, Stainless Steel Wire Cloth, 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed To Steel Frames With Tinned Tacks, Or Galvanized Wire Staples, Or Fixed To Wooden Frames With First Class Hard Wood Bead, Complete All As Specified And Directed. , M&L Welding In Repairs Exc 2.5 Cm But N.Exceeding 2.5Cm In Length (Thickness Of Metal To Be Welded Not Exceeding 6Mm) Including Cleaning Preparing The Surface And Holding The Members In True Position For Maintenance Of Steel Items Such As Gates, Grills, Doors, Windows Etc., Complete All As Specified And As Directed. , Supply And Fix, Clolthes Hook/Hangers Stainless Steel Set Of Five Casted On Strip, Complete All As Specified And Directed. , S &F In Repairs 15Mm Swivel Shower Of Ptmt Any Colour (Minimum Weigth-40Gms) Including 15Mm Shower Arm, 195Mm Long With Bend Of 45 Degree With Flange Of Ptmt Any Colour (Minimum Weight 40Gm) Complete All As Specified And Directed. , Supply And Fixing In Repair Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long, Complete All As Specified And Directed. , S&F In Repairs Of Single Piece European Water Closet White Colour With Soft Seat Cover, 5D Powerful Syphonic Flushing System And Rimless Bowl, Size 67X36x74.5 Cm Complete All As Specified And Directed , S&F In Repair Looking Mirror 600 Mm X 450 Mm Beveled Edge Mirror Of Selected Quality Glass Mounted On 6 Mm Thick Commercial Plywood And Fixed To Wooden Plugs With Steel Screws In Repairs, Complete All As Specified. , S& F For Cabinet Mirror With Plastic / Abs Body With Selve Complete All As Specified And Directed , S & F In Repairs Stainless Steel Sinks With Drainage Board Made Out Of 1.00 Mm Thick Sheet For Kitchen With Plugs, Washers, Waste Pipes, Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cast Iron Cantilever Brackets And Connecting Union To Pipe Overall Size 915 Mm X 460 Mm With Bowl Size 410Mm X 330Mm X 160Mm, With And Including Pvc Waste Pipe And Cp Waste Coupling 32 Mm Dia And Making Good To Disturbed Surfaces, Complete All As Specified. , S&F In Repairs Sinks Made Of Stainless Steel Lmm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar On To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe, Overall Size 495Mm X 420Mm Bowl Size 410Mm X 330Mm X 160Mm, Including Pvc Waste Pipe And Cp Waste Coupling 32 Mm Dia And Making Good To Disturbed Surfaces, Complete All As Specified And Directed. , S&F In Repair 20Mm Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & Highdensity Plastic Ball Screwed For Iron Pipe And Fixed. (Minimum Weight - 20Mm-210Gm)
Contract Date: Jun 17, 2026 Contract Value : 41.47 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Arunachal Pradesh View Result →
43.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
44.
Public Administrative Department #11300262 AOC
Tender For Annual Plan-ANICKAD GP- Wiring of ICDS Office-General Electrical Work - Wiring 2 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point 3 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point 4 90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point 5 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points 6 OD456938/2024-2025:Supply and fixing angle /straight-lined skirt type brass batten/ angle holder with 200 mm plastic shade with 7/9W LED Bulband giving connection as required 7 OD456944/2024-2025:Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover with 9 W LED to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor fle x wire conforming to relevant ISS or extending the original wiring and making good the surface as required.(Mepro /Philips/Crompton/Bajaj make) 8 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture 9 90.3.22.3:Supply & installation of light fittings on flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories andlamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture 10 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 11 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 12 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 13 OD456940/2024-2025:Supply Conveyance, installation, testing, and commissioning of 150mm medium duty 2300 rpm 4leaf, exhaust fan in the plastic body (Almonard/ Crompton make) in the existing opening. fixing necessary bolt and nuts, making good the damages, etc. as required including giving connections with required length of 24/20mm 3core round copper conductor flexible chord etc as required 14 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. 15 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 16 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 17 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 18 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm 19 1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm 20 1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm 21 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm 22 1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm 23 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm 24 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm 25 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm 26 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 27 1.53.2:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable 28 1.53.3:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable 29 OD457140/2024-2025:Supply and laying 1.5 m CAT-6 Patch Cord. Preferred make:-D link or equivalent 30 OD457141/2024-2025:Supply and installation of 16/24 Port 10/100 /1000 Mbps rack mountable switch Make: tp -link TL-SG 1016 D—7200 31 OD457142/2024-2025:Supply and fixing 2 module moulded plastic box/metal box on surface/recess, fixing moduler face plate with RJ 45 CAT 6 jack(Legrand/AMP/MK) 32 OD457143/2024-2025:Testing of each and every node point and making permanent labeling at the I/O box and on the patch panel. 33 OD457144/2024-2025:Supply and fixing of 19, 6U, 500 MM Depth Wall Mount Rack with Front Glass door, cooling fan 90cm ,NVRS, 1 No Power Distribution Unit Rack mounting type - 1 no, Cable Organizer /1U/Loop - 1No.(Netrack or equilent make) 34 OD457145/2024-2025:Supply and installation of CAT-6 24 Port Enhanced Modular type Patch Panel for interconnecting servers and clients including termination charges. Preferred Model:- D-Link or equivalent 35 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 36 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 37 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) 38 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 39 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 40 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 41 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 42 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door 43 90.11.1.10:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 44 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 45 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 46 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 47 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 48 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 49 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 50 90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) 51 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 52 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 53 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) 54 OD456945/2024-2025:Supply and providing 12x3 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 55 OD456943/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 56 OD457126/2024-2025:Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availing 3 phase service connection/Load regularization
Contract Date: Jun 16, 2026 Contract Value : 1.63 Lakh
Government Departments No of Bidders 2
45.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
46.
Housing Urban and Rular Development #11299927 AOC
Tender For Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of: , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead :Of Sectional Area 40 Square Centimetres And Above , Providing And Laying In Position Cement Concrete 1:4:8 (1 Cement : 4 C/Sand : 8 St. Agg. 40 Mm Size) Excluding The Cost Of C/Shuttering - All Work Upto Plinth Level. , Brick Work With F.P.S. Bricks Of Class Designation 75 In Super Structure Above Plinth Level Upto Floor V Level In Cement Mortar 1:6 (1 Cement : 6 C/Sand). , Reinforced Cement Concrete Work In Beam,Suspended Floor Roof Having Slop Up To 15 Degree Landing Balcony Shelf Chajjas Lintels Band Plain Windoe Cills Staircase & Sprial Stair Case Etc. Up To Floor Five Level,Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate20 Mm Nominal Size) , Centering And Shuttering I/C Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , Reinforcement For Reinforced Cement Concrete Work I/C Straightening, Cutting, Bending, Placing In Position And Binding All Complete --Thermo - Machanically -Treated Bars. , Half Brick Masonry With F.P.S. Bricks Of Class Designation 75 In Superstructure Abov Plinth Level Upto Floor V Level In Cement Morar 1:4 (1 Cement :4 Sand) , 12 Mm Cement Plaster Of Mix. 1:6 Cement And Fine Sand Mortar. , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :1:6 (1 Cement: 6 Fine Sand) , Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 154 77, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately).Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Laying In Position Cement Concrete Of Specified Grade 1:2:4 (1Cement :2 Sand : Stone Aggregate 40Mm Nominal Size) Excluding The Cost Of Centring And Shuttering - -All Work Upto Plinth Level , Providing And Applying White Cement Based Putty Of Average Thickness 1Mm Of Approved Brand And Manufacture, Over Plastered Wall Surface To Prepare The Surface Even And Smooth Complete , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade :New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour : , Painting Steel Work With Deluxe Multi Surface Paint Of Req. Shade (Two Or More Coats) Applied Over An Under Coat Of Primer Approved Brand. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Iinternal Work - Exposed On Wall 15 Mm Dia. Nominal Bore , Providing And Fixing Brass Bib Cock Of Approved Quality 15 Mm Nominal Bore , Providing And Fixing Brass Stop Cock Of Approved Quality 15 Mm Nominal Bore , Providing And Fixing Ball Valve (Brass) 15 Mm Nominal Bore High & Low Pressure With Plastic Floatsof Approved Quality Complete , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Tank Isi : 12701 Marked With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 25 Mmnominal Bore , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is: 5382, Leaving 10 Mm Gap For Thermal Expansion, () Single Socketed Pipes. , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is: 5382, Leaving 10 Mm Gap For Thermal Expansion, () Single Socketed Pipes75 Mm Diameter , Providing And Fixing Pvc Door Frame Of Size 50X4 7 Mm With A Wall Thickness Of 5 Mm (± 0.2 Mm), Made Out Of Single Piece Extruded Pvc Profile, With Mitred Cut Joints And Joint With 2 Nos Of Pvc Bracket Of Size 190 Mm X 100 Mm Long Arms Of Cross Section Size 35 X 15 Mm & Self Driven Self Taping Screws, The Vertical Door Profiles To Be Reinforced With 40X20 Mm M.S. Rectangular Tube Of 0.8 Mm , Including Providing Epdm Rubber Gasket Weather Seal Throughout The Frame, Including Jointing 5 Mm Pvc Frame Strip With Pvc Solvent Cement On The Back Of The Profile. The Door Frame To Be Fixed To The Wall Using 8 X100 Mm Long Anchor Fasteners Complete, All As Per Manufacturers Specification And Direction Of Engineer -In- Charge. , 35 Mm Thick Factory Made Solid Panel Pvc Door Shutter, Made Out Of Single Piece Extruded Soild Pvc Profiles, 5 Mm (± 0.2 Mm) Thick, Having Styles & Rails (Except Lock Rail) Of Size 95 Mmx 35 Mm X 5 Mm, Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered ( On Both Side), Having One Side Thickness Of 15 Mm Integrally Extruded On The Hinge Side Of The Profile For Better Screw Holding Power, Including Reinforcing With Ms Tube Of Size 40 Mm X 20 Mm X 1 Mm, Joints Of Styles & Rails To Be Mitered Cut & Joint With The Help Of Pvc Solvent Cement, Self Driven Self Tapping Screws & M.S. Rectangular Pipes Bracket Of Size 190 Mm X 100 Mm Of Cross Section Size 35 Mm X 17 Mm X 1 Mm At Each Corner. Single Piece Extruded 5 Mm Thick Solid Pvc Lock Rail Of Size 115 Mm X 35 Mm, Out Of Which 75 Mm To Be Flat And 20 Mm To Be Tapered At Both Ends, Having 15 Mm Solid Core In Middle Of Rail Section Integrally Extruded, Fixing The Styles & Rails With The Help Of Solvent And Self Driven Self Tapping Screws Of 125 Mm X 11 Mm, Including Providing 5 Mm Single Piece Solid Pvc Extruded Sheet Inserted In The Door As Panel, All Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C. Brass Pillar Tap. , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms15mm Nominal Bore.. , Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete , Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements Weighing Not Lessthan 106 Gms. , Providing And Fixing Mirror Of Superior Glass (Of Approv Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. With Plastic Moulded Frame Of Approved Make And Shades With 6 Mm Thick Hard Board Backing:Rectangular Shape 453X357mm , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests , Marble Stone Flooring With 18 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Cement Mortar 1 :4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Grey Cement Slurry, Including Rubbing And Polishing Complete With : Udaipur Green Marble , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Persqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Gutter (600 Mm Over All Girth) , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595 Mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Is 8225:1987, Light Reflectance Of 85% (Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bs:476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991, In True Horizontal Level Suspended On Inter-Locking Metal Powder Coated T-Grid Of Hot Dipped Galvanised Iron Section Of 0.40 Mm Thick On Silhouette Profile,Rotary Stiched Double Webbed White With 6 Mm Reveal Profile (White/ Black),Comprising Of Main-T Runners Of Size 15X42 Mm Of Length 3000 Mm, Cross - T Of Size 15X42 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 15X42 Mm Of Length 600 Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 22X19x0.40 Mm Of Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 450 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge.With 15 Mm Thick Integral Densified Micro Edge Light Weight Calcium Silicate False Ceiling Tiles , Providing And Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Rockwool Conforming To Is: 8183,Density 48 Kg/ M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete :250X16 Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :250X10 Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Gradeac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :125 Mm , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows Alll Complete With5.5 Mm Thick Glass Panes , Providing Fixing 8Mm Diacp/Ss Jet With Flexible Tube Up To 1 Meter Long With Ss Triangular Plate To Eureopean Type Wc Of Quality And Make As Approved By Engineer In Charge , Constructing Brick Masonry Chamber For Underground C.I. Inspection Chamber And Bends With 75 Class Designation Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Finishedwith F.P.S. Bricksinside Dimensions 455X610 Mm And 45 Cm Deep For Single Pipe Line : , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:30 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes (Weight Not Less Than 10 Kg Per Sqm) Fixing With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size Wit H Necessary Screws .Second Class Teak Wood30 Mm Thick , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required :Size 600X450x200 Mm , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash &Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Three Track Three Panels Sliding Window With Two Glazed & One Wire Mesh Panels With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface Forplaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. , Providing And Laying Polished Granite Stone Flooring In Requireddesign And Patterns, In Linear As Well As Curvilinear Portions The Building, All Complete As Per The Architectural Drawings, With18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cementmortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cementslurry And Pointing With White Cement Slurry Admixed Withpolishing Etc. All Complete As Specified And As Directed By Theengineer-In-Charge.Polished Granite Stone Slab Jet Black, Cherry Red, Elitbrown, Cat Eye Or Equivalent. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead :Of Area 3 Sq. Metres And Below , Disposal Of Moorum/Building Rubbish/ Malba/ Similar Unserviceable , Dismantled Or Waste Material By Mechanical Transport Including Loading, Transporting , Unloading To Approved Municipal Dumping Ground For Lead Upto 1 0 Km For All Lifts, Complete As Per Directions Of Engineer-In-Charge . , Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40 Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : Size 600X450x200 Mm , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above). (Height Upto 1.2 Metre) , Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honeycomb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Longcomplete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.In All Kinds Of Soil. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , Cement Plaster 1:3 (1 Cement: 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement.20 Mm Cement Plaster
Contract Date: Jun 15, 2026 Contract Value : 19.78 Lakh
Government Departments No of Bidders 5
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : 9.44 Lakh
Government Departments No of Bidders 1
48.
Defence #11296184 AOC
Bids Are Invited For Cesium Bromide , Cesium Iodide , Cesium Chloride , Lead Ii Bromide , Lead Ii Chloride , Lead Ii Iodide , Dimethyl Sulfoxide Anhydrous , Methylammonium Bromide , Gammabutyrolactone , Hydrobromic Acid , Bright Electroless Gold Plating Solution , Cesium Chloride , Lithium Chloride , Yttrium Iii Chloride Beads , Yttrium Iii Chloride Powder , Cerium Chloride , Cyclohexanol , Methanol Anhydrous , Fluorine Doped Tin Oxide Coated Glass Slide , Indium Tin Oxide Coated Glass Slide , Ethanol Gr , Indium Foil , Silver Conductive Paste , Bismuth Powder , Chromium Lump , Lead Powder , Selenium Powder , Tin Powder , Tin Oxide Powder , Choline Bromide , Gallium , Gallium Ingot , Cyclohexane Laboratory Reagent , 2 Butoxyethyl Acetate , Isopentyl Acetate , Toluene Anhydrous , Lithium Fluoride , Lithium Nitrate , Lithium Hydroxide Monohydrate , Lithium Tetra Borate , Lithium Carbonate , Beryllium Sulphate , Beryllium Oxide , Magnesium Nitrate Hexahydrate , Magnesium Fluoride , Magnesium Chloride , Silver I Oxide , Silver Sulfide , Copper Ii Oxide , Copper Ii Sulfate , Copper Ii Nitrate Trihydrate , Ammonium Phosphate Monobasic , Silicon Tetrachloride , Silicon Dioxide Nanopowder , Polytetrafluoroethylene , Ethanolamine , Hexamethylenetetramine , Dysprosium Iii Nitrate Pentahydrate , Dysprosium Iii Oxide , Europium Iii Nitrate Hydrate , Europium Iii Oxide , Samarium Iii Oxide , Samarium Iii Nitrate Hydrate , Erbium Iii Nitrate Penta Hydrate , Erbium Iii Oxide , Ytterbium Iii Oxide , Ytterbium Iii Nitrate Pentahydrate , Thulium Iii Nitrate Hydrate , Thulium Iii Oxide , Terbium Iiiiv Oxide , Terbium Iii Nitrate Hexahydrate , Cerium Iii Nitrate Hexahydrate , Ammonium Fluoride , Glycine , Urea , Sodium Nitrate , Hydrogen Peroxide Ww Aq Soln S , Boron Pieces , 2 Methoxyethanol , Boron Nitride , Boric Anhydride , Sylgard 184 Silicone Elastomer Kit , Copper Plate , Boric Acid Spezial Gr , Silver Chloride , Encapsulation Epoxy For Photovoltaics And Oleds Total Quantity : 41394
Contract Date: Ref. Documents Contract Value : 1.09 Crore
Government Departments No of Bidders 6
49.
Rural Development #11293341 AOC
Tender For Providing Internal Works At Vanjarwadi Tal Tasgaon Dist Sangli-2 Providing and laying of hot applied thermoplastic compound 2.5 milimetre thick including reflectorizing glass beads at the rate of 250 grams per square metre area, thickness of 2.5 milimetre is exclusive of surface applied glass beads as per Indian Road Congress : 35. The finished surface to be level, uniform and free from streaks and holes complete.Item / Page No : 12a / 48 3 Supplying and fixing of Plastic body studs with two shanks and without shanks of Swareflex or equivalent in yellow, red and white color made of Abstrone Butadyne Styrine body with size 100 milimetre X 100 milimetre X 17.9 milimetre, having reflective panels of 34 special Swaro glass reflective elements embedded in plastic and 19 degrees tilted to provide the highest reflectivity. Having reflective panels in yellow, red and white plastic with yellow, red, white or green Swaro glass elements. The studs shall have a compressive strength test certificate of 25 tons in accordance with ASTDM D 4280 and successfully passing retro reflectivity test as per EN 1463-1 and the road test EN 1463-2 from a reputed laboratory. The fixing of the road studs shall be done by using a recommended two component epoxy. In addition two holes should be drilled in the depth of 50 milimetre on the road for the version with two shanks.Item / Page No : 127 / 386 4 Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175 5 Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 13 / 178 6 Supplying hard murum / kankar at the road site, including conveying and stacking, excetra complete.Item / Page No : 29a / 25 7 Spreading hard murum / soft murrum / gravel or kankar for side width, excetra complete.Item / Page No : 30 / 25 8 Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering, excetra complete.Item / Page No : 31 / 25 9 Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0 10 Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)Item / Page No : 3 / 0 11 Providing and fixing Road junction / Information sign board of size 0.90 metre X 0.60 metre prepared on 16 gauge mild steel sheet with angle iron frame of size 35 milimetre X 35 milimetre X 5 milimetre including painting with one coat of zinc cromate stoving primer and two coats each of green/ white back ground and back side gray stove enamelled, bonded with red retro-reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective coat retaining 100 percent reflection including two angle iron post of size 50 milimetre X 50 milimetre X 5 milimetre of 3.65 metre long inflated at bottom drilled on top and painted in white and black bands of 30 centimetre. with 4 numbers high strength galvanised iron bolts and nuts of size 10 milimetre diameter and 20 milimetre long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 centimetre X 60 centimetre X 75 centimetre size as directed by Engineer-in-charge, excetra complete. Mild Steel Board with Engineering Grade.Item / Page No : 47 / 64
Contract Date: Oct 27, 2025 Contract Value : 14.99 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
50.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
TenderDetail
Loading tenders