View Bid Results For Glass Ducts Tenders

We found 1074 Bid Results related to glass ducts tenders. You can find Contractor details who won glass ducts tenders along with contract details in Bid awards announcements section.

Filters
Stage
754
189
131
Tender Publishing Platform
104
970
State / UT
32
151
132
94
68
68
64
57
54
53
46
35
30
28
25
23
19
18
16
12
12
11
10
9
9
7
6
6
4
3
2
1
1
Contract Value
344
109
418
203
Publish Date
5
0
0
0
0
Sector
28
417
133
128
79
76
50
42
20
15
15
13
12
12
12
8
8
6
4
4
4
3
3
3
2
2
1
1
1
Ownership
7
426
393
139
107
4
3
2
Within keyword
Active filters:
Showing 1–22 of 1074 tenders matching your filters
1.
Defence #11496759 Technical Bid
Tender for Material And Labour For Plain Cement Concrete (1:3:6) Type C1 (Using 20 Mm Graded Crushed Stone Aggregate For Fixing Holdfast Complete All As Specified And As Directed. , Supply Only Water Proofing Compound. , Material And Labour For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc , Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate ) As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specifed And Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour For Granite 20Mm Thick (Of Any Type) Work (Table Rubbed And Polilshed) In Steps, Jambs, Pillars, Window-Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In Wite Cment (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over 15 Mm Thick Screed Bed In Cement Mortar 1:6 All As Specified. , Material And Labour For Granite 20Mm Thick (Of Any Type) Work (Table Rubbed And Polilshed)For Wall Lining (Veneering To Wall) 12Mm Thick In Cement Mortar (1:3) And Pointing In Wite Cment (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over 10 Mm Thick Rendering In Cement Mortar 1:3 All As Specified. , Supply And Fix 2Nd Class Hard Wood, Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue, Pinned At Joints Complete All As Specified And Directed , Supply And Fix 30Mm Thick Second Class Hard Wood Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauge Etc With Plain, Chamfered Or Rounded, Mitred Beads (With Sash Bars) For Securing Glass Etc, Sizes Of Members Of Shutters All As Specified In Ssr Part-I Section 8 Clause 8.24 (B) Complete All As Specified And Directed. , Supply And Fix 35Mm Thick 2Nd Class Hw Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc.Divided Into Squares, With Plain,Chamfered Or Rounded,Mitred And Rebated Sash Bars,Any Numbers, Edges Of Framing Plain,Chamfered Or Rounded. Fitted With Cut And Mitred Beads For Securing Glass,Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats Complete All As Specified And Directed. , Supply And Fix 30 Mm Thcik Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified And Directed. , Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix 100 Mm Size Stainless Steel Butt Hinges, Complete All As Specified And As Directed. , Supply And Fix 75 Mm Size Stainless Steel Butt Hinges, Complete All As Specified And As Directed. , Supply And Fix 200 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Extruded Aluminum Alloy Handles, Fabricated Type, Anodized Complete All As Specified And As Directed , Supply And Fix 100 Mm Extruded Aluminum Alloy Handles, Fabricated Type, Anodized Complete All As Specified And As Directed , Supply And Fix 300 Mm Long Aluminum Alloy Anodised Sliding Door Bolt With Hasp, Staple (Bolt Type) And Fixing Clips Of Steel, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminum Alloy Complete All As Specified And As Directed. , Supply And Fix Stain-Less Steel Wire Cloth, 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40 Mm And Fixed With Stainless Wire Staples Complete All As Specified And As Directed. , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Box Type Steel Windows With Side Hung Shutters Both Mosquito Proof And Glazed Shutter Including Projecting Type Hinges With Steel Handle And Steel Peg Stay With Glazing Bars And 12 Mm Square Bar Or Ground Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And As Directed. , Supply And Fix Steel Ventilators With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete All As Specified And As Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete All As Specified And As Directed. , Material And Labour For Mild Steel Small Articles Such As Clamps, Hold Fast, Wind Ties, Bends, Anchorage Plate, Clamps For Holding Rwp, Brackets, Suspenders For Ceiling Etc Conforming To Fe-410-0 Or Fe-310-0 Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed Note: To Be Executed For Provison Of Ridges And Hips, Valley Etc Complete All As Specifed And As Directed , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:4) Complete All As Specified And Directed. , Material And Labour For 60Mm Thick M-40 Grade Cement Concrete Coloured Interlocking Paver Block Any Shape And Size Conforming To Is 15658-2006 With Grey Cement And Pigment As Approved Laid Over And Including 25Mm Thick Sand Cushion And Joints Filled With Sand Complete All As Specified And Directed. , Material And Labour For 75 Mm Thick Plain Cement Concrete 1:3:6, Type C-1, (Using 20 Mm Graded Aggregates) As In Plinth Protection Etc, Finished Even And Smooth Without Using Extra Cement Complete All As Specified Including Joints Filling With Sealing Compound Grade A Complete All As Specified And Directed. , Material And Labour For 100Mm Thick Cement Concrete 1:2:4 Type B-2 (Using 40Mm Graded Stone Aggregate ) As In Flooring, Hardstanding Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate ) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm Thick, In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry & Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete Of Item All As Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8Mm Thick Area Of Each Tile Exceeding 0.18 And N.Exc 0.38 Sqm In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry & Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete Of Item All As Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exc 0.18 And N.Exc 0.38 Sqm , In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 10Mm Thick Screed Bed In Cm 1:4 Complete All As Specified And Directed. , Material And Labour Coloured/ Printed Glazed Ceramic Tiles 7Mm Thick Not Exc 0.15 Sqm In Area In Vertical Surfaces I.E. Dado, Skirting, Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, Laid Over And Including Screed Or Screed Bed 10Mm Thick In Cement Mortar 1:4, Complete All As Specified And As Directed. , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Material And Labour For 5Mm Thick Rendering On Fair Faces Of Brick Or Concrete Surface In Cm 1:3 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Make: Berger Weathercoat Anti Dustt Or Equivalent Of Asian Paint Or Nerolac) Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Ceiling Surface And Applying Three Coats Of White Wash Complete All As Specified And Directed. , Material And Labour For Preparation Of Old Distempered Surface Of Wall Including Cornices Etc. By Washing, Rubbing Down,Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salt And Trading Oil And Greasy Spots And Stopping Of Distempered Surfaces And Applying One Coat Of Acrylic Distemper Of Approved Shade On Surface Of Wall Complete All As Specified And Directed. , Material And Labour For Complete Removal Of Existing Treatment On Wall Surfaces By Scrapping, Washing & Rubbing Down Including Applying A Layer 1 Mm Wall Care (Putty) For Making The Surface Even & Smooth Etc Complete All As Specified. , Supply And Fix Sheet Glass 3.0 Mm Thick Ordinary Quality And Glazing With Oil Putty/Wooden Beads In Squares Not Exc. 0.50Sqm In Each Pane Complete All As Specified And Directed. , Supply And Fix 4 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty/Wooden Beads In Squares Not Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed , Material And Labour For Preparation Of New Or Previously Untreated Surface Of Wood Or Wood Based Materials Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer All As Specified. , Material And Labour For Preparation Treating Small Articles Such As Stop, Covers Gully Grating, Holdfasts, Ends Of Post Backs Of Chowkats, Etc. Area N.Exc 0.50 Sqm Each And Applying Tar Or Coal Tar Black Paint To Back Of Chowkats. , Material And Labour For Preparation Of Old Painted Surface Of Wood And Wood Based Materials By Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salt And Trading Oil And Greasy Spots Of Any Discription, Not Otherwise Described, Over 10Cm In Width Or Girth And Applying One Coat Of Synthetic Enamel Paint, White Or Tinted Complete All As Specified And Directed. , Material And Labour For Preparation Of Old Painted Surface Of Steel And Iron By Brooming Down Or Steel Wire Brushing, Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salt And Trading Oil And Greasy Spots Of Any Discription, Not Otherwise Described, Over 10Cm In Width Or Girth And Applying One Coat Of Synthetic Enamel Paint, White Or Tinted Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 15Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 20 Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Hand Basin White, Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Pvc Waste Coupling And 32 Mm Dia Pvc Waste Pipe Including Fixing Of Tap, Waste Fitting Etc Complete All As Specified And Directed. , Supply And Fix In Repair Bib Taps With Wall Flange 15Mm Bore, Fancy Type, Quarter/Half Turn, Brass Chromium Plated, Long Body With Capstan Head And Cup Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Accessories Complete All As Specified And Directed. , Supply And Fix In Repair 125 Mm Dia, Chromium Plated Swivel Type Shower Rose With 195 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15Mm Bore Iron Pipe All As Specified And Directed , Supply And Fix In Repair Bath Wall Mixer With 15Mm Bore (Dia) Spout, Chromium Plated With Long Bend Pipe For Over Head Shower Including Flanges Complete All As Specified And As Directed. , Supply And Fix In Repair Pillar Taps, Cast Copper Alloy, With Capstan Heads, Fancy Type, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered ‘Hot Or ‘Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe 15 Mm Bore Complete All As Specified And Directed. , Supply And Fix In Repair Cp Stop Valve/Angle Valve 15 Mm Bore, Fancy Type Cromimum Plated With Long Shank And Cup (Concealed Type), High Pressure Crutch Or Butter Fly Handle Screwed Both Ends Screwed For Iron Pipe Or For Unions Complete All As Specified And Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 1000 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places With Fittings And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 500 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places Complete And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix Ball Valves 20Mm Bore Dia Of Pipe High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed (Minimum Weight 20Mm-210Gms). , Supply And Fix In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Supply And Fix In Repair Pvc Valve, Symphonic Action Type, Flushing Cistern 10 Liters Capacity Low Level White With Inlet ,Ball Valve ,Float And Handle Including Brocket Complete All As Specified And Directed By Engineer In Charge , Supply And Fix 110Mm Dia Pvc (Swr) Pipes, Presure Rate Having 6 Kgf Single Socketed In Any Length With Rubber Ring Joints And Laid In Trenches As In Waste/Soil Pipe Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Complete All As Specified And As Directed. , Supply And Fix 75Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Or Floor Complete All As Specified And As Directed. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 75 Mm Bore Complete. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 110 Mm Bore Complete. , Supply And Fix Pvc Vent Cowls Of 110Mm Dia Etc Complete All As Specified And As Directed , Supply And Fix Pvc Vent Cowls Of 110Mm Dia Etc Complete All As Specified And As Directed , Supply And Fix In Repair Vitreous China Wash Down Water Closed Pan (Pedestal Pattern) With P Or S Trap White, Including Connection To Trap And Cistern, Flush Pipe Including White Plastic Water Closet Seat Cover, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Making Good Disturbed Surface Of Floor Complete All As Specified And Directed. , Supply And Fix, In Repair Vitreous China Wash Down Water Closet Of Orissa Pattern Size 580 X 440 Mm White With Integral Foot Rests Including Removing Filled Lean Concrete From Sunken Portion And Putting Of Lean Concrete After Treatment Of Sunken Slab, Connection To Trap And To Flushing Pipe Etc Complete And Making Good To Floor Complete All As Specified And Directed. , Supply And Fix In Repair Plastic Water Closet Seat Cover, White, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Fixed Wc Pan Complete All As Specified And Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area N.Exc. 1.5 Sqm Including Builders Hardware Each Complete All As Specified And As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each Including Builders Hardware Complete All As Specified And As Directed. , Taking Down Shutters Of Any Description N Exc 1 Sq. M Each Removing To Store All As Specified. , Taking Down Shutters Of Any Description Exc 1 Sq. M And N Exc 2 Sq. M Each Removing To Store All As Specified. , Dismantling, Floor Hearth Or Wall Tiling Inclduing Cement Mortar Bedding And Removing Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Or Cement Lime Mortar , Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. , Demolition And Breaking Up Drain Waste Pipes (Sgsw, Ac Or Rcc, Ci ) Of Internal Dia 75/110 Mm, Set In Cement Mortar In Any Position Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc. 15 Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc. , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Trusses Etc Complete All As Specified. , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
3.
Defence #11427184 Technical Bid
Tender for Sch A Part-I To Xi Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Internal Water Supply) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (Sewage Disposal ) , Total Amount Of Sch A Part-Ix (External Water Supply) , Total Amount Of Sch A Part-X (External Electric Supply) , Total Amount Of Sch A Part-Xi (Hot Water Supply) , Schedule A Part-Xii (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , Supply And Fix Engineering Body Desert Cooler Electric Driven Single Phase 230 Volts, Having Nominal Air Flow Capacity Of 4500 Cum Per Hour,Tank Capacity 105 Ltrs,With Auto Louver Movement,With Min Ait Throw 15 Mtr Complete All As Specified And As Directed By Engr-In- Charge. Make:Kenstar Turbocool Neo Hc 105 Or Techno Commercial Equivalent Make. , Supply, Installation, Commissioning Refrigerator, Electric Driven (Single Phase),Capacity 340 Ltrs , Double Door, Smart Inverter Compressor Of Latest Model, Eco Friendly , Digital Display, Toughened Glass Shelves Complete With All Accessories All As Specified And Directed By Engineer In Charge. , Supply Installation, Commissioning Of Metal Top Deep Freezer Double Door Single Phase Storage Type Deep Freezer 320 Ltrs Cap Of Latest Model Complete With All Accessories All As Specified And Directed. , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva All As Specified And Directed , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. , Design, Fabricate, Supply, Install, Testing And Commissioning Of Complete Electrical Chimney/Electrical Hood With Filters Comprising Of Following Items. A) Supply,Install,Testing And Commisssioning Of Kitchen Hood Made Ss 304 Matt Finish 1 Mm Thick Wall Mounted Type With Removable Grease Stop And Fixing Brackets,Oil Drain Channel Of Size 36 X 72 Of Required Length Including Drain Collector & Connecting With Exhaust Ducting Etc Complete All As Specified And As Directed-2 Rm B) Supply And Install Removable Grease Stop Filters Suitable Size Complete All As Specified And As Directed- 02 Nos C) Supply,Install,Testing And Commissioning Exhaust Blower Of Capacity 1 Hp ,240 Volts Single Phase 1440 Rpm Connecting With Exhaust Ducting And Suitable Copper Cable Connecting Complete All As Specified And As Directed:-01 Nos D) Supply And Installation Collar Damper Of Suitable Size For Connecting Between Duct And Exhaust Hood Made Out Of 20 Swg Complete All As Specified And As Directed.-02 Nos E) Supply And Fix Anti Vibration Dush With Ms Fabricated Stand Frame Of Suitable Size For Resting Blower Complete All As Specified And As Directed. , Supply And Install Exhaust Ducting Of Size 500 Mm X 500 Mm Made Of Gi Sheet 24 Swg Including Connecting With Ceiling Mounted Exhaust Hood Up To Terrace With Ms Angle Frame 25 X 25 X 3 Mm Thick,Fixing Of Brackets With Nut Bolts,Gaskets Supporting Thread Rod,Channels Etc,Including Painting The Steel Surfaces With Two Coats Of Synthitic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Taps, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down High Pressure With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S&F Health Faucet (Abs Body) Suitable For 15 Mm Dia Pipe With 1 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified. , S&F Two Way Bib Tap 15Mm Dia, With Wall Flange And Aerator Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. , S&F Wall Mixer For Mixing Hot And Cold Water And Bend For Connecting To Shower,15 Mm Bore Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S & F Flush Cock, Push Type 15Mm Dia, Cast Copper Alloy, Fancy Type, Chromium Plated, For Iron/Cpvc Pipe Or Unions Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Tap With Swan Neck, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down With Long Screwed Shanks And Fly Nuts Screwed For Iron/Cpvc Pipe And Fixed Complete All As Specified And As Directed. , S & F In Replacement Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , S & F Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 10 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb Four Pole 25 Ka, 100 annual periodical maintenance With Fixed Thermal And Magnetic Settings As Incomer Ip43 Protection Double Door : Plain 4 Way With Suitable Rated Busbar,Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separetely. , S&F In Replacement, Mccb 4 Pole, 415 V, Adjustable Type, 100 Amps With Breaking Capacity 25 Ka And Making Connection With Suitabl Size Of Copper Lugs Etc Complete All As Specified And As Directed. , M&L For Construction Of New Reinforced Cement Concrete Septic Tank For 50 Users Designed To Carry Sewage And Sludge Water, Plain Cement Concrete 1:4:8 Below Foundation, Reinforced Cement Concrete Roof Slab Including Beams, Etc, Using Tmt Crs Bars Grade Fe-500D/Fe-550D, With Vent Shaft , Manhole Opennings With Cover Connection, Including Excavation Earthwork In Any Type Of Soil/ Ordinary Rock Complete All As Shown On Td Drg. Afb/Td/228/2018(S) Sheet 1R/1 Of Ce (Af) Bangalore Zone And As Specified By Engineer-In-Charge. , M&L For Construction Of Soakage Well, Including Excavation In Any Type Of Soil/Ordinary Rock, Foundation In Plain Cement Concrete 1:3:6 Walls Of Honeycomb Masonry With Top Ring Of M-25 Concrete Including Intersepting Chamber Screen Chamber Made Of Fly Ash Brick Masonry In C:M 1:4, Rcc/Dwc Complete Filled With Brick Bats Of Size Of Size 1.80M Dia And 3.0 M Effective Depth All As Shown On Drawing No Cepz/2019/Td/03 Sheet No 1/2 And 2/2 And As Specified By Engineer-In-Charge. , S&F Of Grease Trap Of Capacity 500Lts Having Length X Width X Height Of 1150 X 939 X 765 Mm, To Be Installed Underground Complete All As Specified And As Directed By Engineer-In-Charge. Make : Supreme, Cat No Rlugtp0500gb And Equivalent Series As Approved By Engineer-In-Charge. Note: (A) Excavation, Plain Cement Concrete And Brickwork For Installing Grease Trap To Be Paid Separately Under Respective Items. , Cutting Existing 150 Mm Dia Di Pipe For Inserting Tee Of Size 150X150x50 Mm Including Lead Joint And Excavation Etc Complete All As Specified And Directed , M&L For Construction Of Valve Pit/Chamber Of Internal Dimensions 900 Mm X 900 Mm X 900 Mm, Using Plain Cement Concrete 1:4:8, Type D-2, Using 40Mm Graded Stone Aggregates For Foundation, 23 Cm Thick, Brick Wall Built In Cement Mortar (1:4) ,15 Mm Thick Rendering All Around The Brick Work In Cement Mortar (1:6), 75 Mm Thick Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregates In Coping Including Necessary Form Work, 3 Coats Of White Wash On Rendered Surfaces And On Coping, 5 Mm Thick Mild Steel Top Sheet Cover With Frame Made Out Of 40X40x6 Mm Angle Iron, Locking Arrangement, Including Painting Of Steel Surface With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Maharashtra View Result →
4.
Defence #11413644 Technical Bid
Tender For Repair And Maintenance Of Chs Alongwith Connected Items At Various Units At Bhimbat,Thasgam & Drass Under Ge Kargil.- 1 Dismantling The Existing Burner Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed. 2 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For De- Carbonization , Descaling And Refractory Cement And Assemble The Same And Testing Complete All As Specified And Directed. 3 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr By Using Brush And Vaccum Cleaner Complete All As Specified And Directed. 4 M&L For Descaling Of Boiler By Circulating The Descaling Chemical Using Circulating Pump Into The Boiler And Kept It For Approx 4 Hours For Descaling And Flushing Off The Chemical After Descaling Of Boiler Complete All As Specified And Directed. 5 M&L For Refractory Cement / Heat Resistance Cement Of Boiler Assembly Of Heating Plant Complete All As Specified And Directed. 6 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 20Mm Complete All As Specified And Directed. 7 Supply And Fixing In Replacement Of Solenoid Valve Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 8 S&F In Repair Of Photo Cell Sensor Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Make - Cofi Complete All As Specified And Directed. 9 S&F In Repair Hydraulic Pressure Gauge Showing Reading 0-20 Bar With Accuracy +/- 2.5% To Be Connected With 15 Mm Dia Gi Pipe Complete With Suitable Size Of Battery Complete All Accessories And Protection Cover. 10 S&F In Repair Digital Temperature Controller (Dtc) Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 11 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 12 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 13 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 14 S&F In Repair Of Nozzel 60 Degree Complete All As Specified And Directed. Make : Danfoss Or Equivalents Make. 15 Replacement Of Old Unserviceable Minor Part For The Control Panel Including Repairing Of Wiring Etc As Per Existing, Complete All As Specified And Directed By Engr-In-Charge. 16 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 17 S&F In Repair Thermostat Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 18 S&Fin Repair Sequence Controller Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 19 S&F In Repair Contactor 25A, 230V/440V Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 20 S&F In Repair Of Contactor 230/ 440V Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 21 S&F In Repair Relay 4.5 - 7.5 Amps, 3 Phase, 50 Hz, 415 Volts Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 22 S&F In Repair Relay 6 - 10 Amps,3 Phase, 50Hz, 415 Volts Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 23 S&F In Repair Diesel Filter Assembly With Drain Port Complete As Per Sample. 24 S&F In Repair Fuel Pipe For Burner As Per Sample. 25 M&L For Complete Rewinding Of Electric Motor Of Capacity 5 Hp 3 Phase 415 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 26 M&L For Complete Rewinding Of Electric Motor Of Capacity 1 Hp Single Phase 230 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 27 All As Per Item No 26 Above But Capacity 0.5 Hp Single Phase 230 Volts. 28 Repair Of Chimney 7Mtr High Complete With Welding Including Iron Pieces, Plates, Outlet Cover And Necessary Modification And Cleaning Complete Removal Of All Kinds Of Dust Both Internal And External Parts And Free From All Kind Of Dust/Dirty Spots Of Chimney, Complete All As Specified And Directed By Engr-In-Charge. 29 M&L For Elastomeric Nitrile Rubber Foam Insulation Sheet For Ducts Having Anti Microbial Properties Having Thickness 10 Mm With Suitable Adhesive Complete All As Specified. 30 Dismantling Of Unserviceable/Damaged Hepa Filters And Supply And Fixing Of Hepa Filters With Al Box And Flange Type Of Size 640 X 460 X 50 Mm With Frame Having Efficiency Of 3 Microns Complete All As Specified. 31 M&L For Cleaning Of Existing Hepa Filters With Pressurized Potable Water By Using Pressure Pump And Water Spray Gun, Dry The Filters With Compressed Air After Cleaning Complete All As Specified. 32 Supply And Topping Up Of Antifreeze (Coolant) Suitable For -35 To -40 Degree Celsius To Be Filled In Reservoir Tank For Central Heating System As Instructed By Engr-In-Charge. 33 S&F Of Threaded Thermometer Having Range -50 To +100 Degree Celsius With Accuracy +/-2.5% To Be Fixed On 15 Mm Dia Gi Pipe Complete With All Accessories. 34 M&L For Rewinding Of Ahu Blower Motor Cap 5 Hp And Testing After Repair Complete All As Specified. 35 M&L Charges For Servicing Of Air Handling Units Including Blower Cleaning, Balancing Of Blower Motor Pully Complete All As Specified. 36 S&F In Replacement Of Supply Air Diffuser Alongwith Collar Damper Of Size 600 X 600, Neck Size 450 X 4550Mm All As Specified. 37 M&L For General Maintenance, Inspection And Servicing Of Chiller Unit By (Make-Bluestar Model No. Xac2S-010R2) Cleaning Of Condenser And Evaporator Coils Of The Chiller Unit By Using Specialized Cleaning Solution And Pressure Washing, Inspections Of The Compressor And Water Pump For Leaks, Noise, And Proper Functionality, Verifying The Integrity Of Electrical Components, Including Wiring, Breakers And Sensors, Parts, Lubrication Of Moving Parts, Checking Of Any Refrigerant Leaks, Checking Performance Testing And Optimization. 38 M&L For Repair/Replacement Of Faulty Components, Fixing Any Refrigerant Leaks And Vaccum Testing And Performance Evaluation After Refilling, Replacement Of Worn Out Gaskets, Seal And O-Rings For Chiller Of Capacity 9.2 Tr Complete All As Specified And Directed. 39 Supply And Charging Of Refrigerant Gas R-407C As Per Existing For Chiller Of Capacity 9.2 Tr And Testing After Charging Complete All As Specified And Directed. 40 Supply And Topping Up Of Compressor Oil As Per Existing Grade Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 41 Supply, Installation, Testing In Replacement Of Hermetic Type Scroll Compressor Unit , Suitable For 9.2 Tr Capacity Chiller Unit (Make-Bluestar Model No. Xac2S-010R2) Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Bluestar/Godrej / Lg Or Equivalent. 42 S&F In Replacement Of Expansion Valve As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 43 S&F In Replacement Of Filters & Driers As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 44 S&F In Replacement Of Pressure Switches As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 45 S&F In Replacement Of Control Relays As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 46 S&F In Replacement Of Fan Motor Of Cooling Tower As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 47 S&F In Replacement Of Temperature Controller As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 48 Dismantling The Existing Burner Assembly Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed By Engr-In-Charge. 49 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 30000 Kcal/ Hr For De- Carbonization And Assemble The Same And Testing Complete All As Specified And Directed By Engr-In-Charge. 50 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity Capacity 30000 Kcal/ Hr By Using Brush And Vaccum Cleaner Or Blower Complete All As Specified And Directed By Engr-In-Charge. 51 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Gun Metal Of Size 25Mm Complete All As Specified And Directed By Engr-In-Charge. 52 S&F In Repair Of Photo Cell Sensor Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr Complete All As Specified And Directed By Engr-In-Charge. 53 S&F In Repair Dtc Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 54 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 55 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 56 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 57 S&F In Repair Of Nozzel 60 Degree Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 58 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 59 S&F In Repair Thermostat Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 60 S&Fin Repair Sequence Controller Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 61 S&Fin Repair Solenoid Valve Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 62 S&F In Replacement Of Chimney Exhaust Of 6 Inch Dia Made Of Auminium Sheet Including Bends And Outlet Cover Complete All As Specified And Directed By Engr-In-Charge. 63 Dismantling The Existing Radiator Unit Of Capacity From 3000 To 6000 K Cal Per Hour, Taking It To Nearest Workshop Cleaning The Complete Unit With Coil Shine Chemical, Detecting The Leakage Portion By Applying Nitrogen Gas Pressure, Brazing The Leakage Portion, Refixing The Same Unit From Dismantled Location Including Testing On Load Complete All As Directed At Site By Engineer-In- Charge. 64 Supply And Laying 3 Layer (Inner Antimicrobial, Outer Uv Stabilized) Isi Marked Is-15801 Pp-R Pipe And Pp-R Plain Fittings In Walls Or Laying In Floors Complete Of Size Outer Dia 25 Mm Including All Fittings (Surface Remitting Also Included). 65 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 25Mm Complete All As Specified And Directed. 66 S & F In Replacement Thermostat Suitable For 126/165/195/310 Litres Capacity Refrigerators All As Directed. 67 Supply And Charging Of Refrigerant Gas As Per Existing For Refrigerator Of Capacity 126/165/195/310 And Deep Freezer Of Capacity 300/320/400/500 Ltr Capacity Including Testing After Application Of Nitrogen Gas Pressure To Find Out Any Leakage, Brazing And Stopping Of All Leakage Detected, Re-Application Of Nitorgen Pressure To Ensure Leak Proof Gas Circulator System Flushing Out The Nitrogen Gas Complete All As Specified And Directed. 68 S&F In Replacement Of Compressor Unit , Suitable For 165/195 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 69 S&F In Replacement Of Compressor Unit , Suitable For 126 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 70 S&F In Replacement Of Compressor Unit , Suitable For 310 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 71 S&F In Replacement Of Copper Capillary Tube With All Fittings For Refrigerator Of Cap 126/165/310 Ltr Complete All As Specified. 72 Repair To Voltage Stabilizer For Automatic Operation Single Phase Naturally Air Cooled, Indoor Type Designed For Output Variation Between 170 To 250 V With Output Voltage Stablized At 230 V With Accuracy Of +/- 2.5 % And Capacity 1 Kva And Making Connection With Ac Complete All As Specified & Directed. 73 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 50 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 74 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 25 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 75 M&L For Replacement Of Unservicible Inner Shell Made Of Stainless Steel 1.5Mm Thick Suitable For Geyser Inclusive Of Glass Wool As An Insulating Material For Geyser Of Capacity 25-50 Ltrs. 76 M&L For Replacement Of Thermostat For Geyser 0 To 80˚ C Complete All As Specified And As Directed By Engineer-In-Charge. 77 M&L For Flexible Pvc Connection Pipe For Geyser Of Length 1.5 Feet As Per Sample. 78 M&L For Replacement Of Pressure Release Valve For Geyser Of 25 Ltr Having Size 15Mm Dia. 79 M&L For Replacement Of Heating Element For 25 Ltr Geyser Capacity Round Type 1.5 Kw As Per Sample. 80 M&L For Replacement Of Heating Element For 25 Ltr Cap Triangle Type 1.5 Kw As Per Sample. 81 M&L For Replacement Of Geyser Assembly Suitable For 25 Ltr Geyser As Per Sample. 82 Repair And Replacement Of Kerosine Oil Batti Including Blower, Burner For Hammam 500 As Per Sample Complete All As Specified And Directed. 83 S&F Brass Tap Size15/20 Mm For Hamam As Per Sample Complete All As Specified And Directed. 84 M&L For Replacement Of Heating Element As Per Sample Suitable For 500Ltr Hammam As Per Sample. 85 S&F In Repair Of Compressor New Sealed Unit, Suitable For 300/320 Ltr Capacity Deep Freezer And Testing On Full Load Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete In All Respect Complete All As Specified And Directed By Engr-In-Charge.Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 16
Jammu And Kashmir View Result →
5.
Defence #11392756 Technical Bid
Tender for Demolition Of Brick Work /Stone Masonry Masonry Built In Cement Mortar Of Any Description Complete All As Specified And As Directed. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc Complete All As Specified And As Directed. , Taking Down Shutters Of Any Description Exc 1 Sq. M And N Exc 2 Sq. M Each Removing To Store Complete All As Specified And As Directed. , Demolition Of Cement Concrete And Paving Not Exc 15 Cm Thick (Below Or Above Ground Level) Complete All As Specified And As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area N.Exc. 1.5 Sqm Including Builders Hardware Each Complete All As Specified And As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Area Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each Including Builders Hardware Complete All As Specified And As Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering Complete All As Specified And As Directed. , Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Etc Complete All As Specified And As Directed , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed. , Taking Down Cement Plaster Of Any Description Hacking For Key Or Raking Out Joint On Old Brick Work/ Stone /Concrete Surface Etc Complete All As Specified And As Directed , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding But Not Backing Complete All As Specified And As Directed. , Excavating In Post Holes (Or Similar Holes) Each Not Exceeding 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50M And Making Good Surfaces In Soft/Loose Soil Complete All As Specified And As Directed. , Material And Labour For Sand Filling Under Floors Or In Foundations Including Watering And Consolidation Under Bedding For Interlocking Tiles Etc Complete All As Specified And As Directed , Material And Labour For Plain Cement Concrete Type D-2 1:4:8 (With Using 40 Mm Graded Stone Aggregates) As In Foundations And Mass Concrete Etc Complete All As Specified And As Directed , Material And Labour For Providing Cement Concrete Type B0 1:2:4 (Using 12.50Mm Graded Stone Aggregate) In Copings, Parapets And, Kerbs, Water Troughs/ Chajjas And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating As Directed , Material And Labour Brickwork (Old Size Brick) With Sub Class ‘B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:4 Etc Complete All As Specified And As Directed , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Jambs, Pillars, Window- Cills,Cooking Platforms, Working Table And Like Over 20 Mm Thick Screed Bed Or Bedding Layer In Cement Mortar (1:4), Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite , Material And Labour For 20 Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) For Wall Lining (Veneering To Wall) 10Mm Thick In Cement Mortar (1:3) And Pointing With White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. , Supply And Fix 30 Mm Thcik Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified And As Directed. , Supply And Fix 30Mm Thick 2Nd Class Hw Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc.Divided Into Squares, With Plain,Chamfered Or Rounded,Mitred And Rebated Sash Bars,Any Numbers, Edges Of Framing Plain,Chamfered Or Rounded. Fitted With Cut And Mitred Beads For Securing Glass,Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats Complete All As Specified And As Directed. , Supply And Fix Solid Pre Lam Pvc Door Frame/Chowkhat Of Size 50 X 47Mm Made Out Of 5Mm Prelam Pvc Sheet Reinforced With M.S. Square Tube 15Mm X 15Mm. The Two Vertical Door Profiles Are To Be Reinforced With 40Mm X 20Mm Ms Tube 19 Guage. Door Frame Need To Be Fixed To Wall Using 100 Mm Long Ms Screws Etc Complete. , Supply And Fix Factory Made Solid Panel Pre Lam Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes 19 Guage Thickness And Size Of 40Mm X 20 Mm For Stiles, Top,Bottom And Lock Rails. M.S. Frame Shall Be Covered With Heat Moulded Prelam Pvc ‘C Channel Having A Pvc Sheet Strip Of 30Mm Width Stuck Inside With Solvent Cement. 110 Mm Width Forming Stiles In Which 100Mmm Should Be Flat And 5 Mm Should Be Tapered, And 5 Mm Thich, 135 Mm Wide Prelam Pvc Sheet For Top And Bottom Rail In Wchich 125 Should Be Flat And 5 Mm Should Be Tapered On Either Side Of Panel, Also For Lock Rail 145 Mm Sheet, 125 Should Be Flat And 5 Mm Tapered On Either Side. And Additional 5 Mm Thich Pvc Strip Struck Inside Of C Channel. And Prelam Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Prelam Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement Etc Complete , Supply And Fix 100 Mm Size Stainless Steel Butt Hinges, Complete All As Specified And As Directed. , Supply And Fix 200 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section Complete All As Specified And As Directed. , Supply And Fix 150 Mm Extruded Aluminum Alloy Handles, Fabricated Type, Anodized Complete All As Specified And As Directed , Supply And Fix 300 Mm Long Aluminum Alloy Anodised Sliding Door Bolt With Hasp, Staple (Bolt Type) And Fixing Clips Of Steel, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminum Alloy Complete All As Specified And As Directed. , Supply And Fix Stain-Less Steel Wire Cloth, 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40 Mm And Fixed With Stainless Wire Staples Complete All As Specified And As Directed. , Supply And Fix As In Repair Aluminium Extuded Section Body Door Closer Hydraulically Regulated, Designation No. 3,Universal Type, Suitable For Door Shutters Of 851 To 1000 Mm In Width And Of Weight Between 61 To 80 Kg Complete All As Specified. , Taking Down And Refixing Aluminium Window, Shutters And Making Unserviceable Shutter To Serviceable Shutter (Which Incls Replacing Roller,Rubber Beading Etc) Complete All As Specified And Directed. , Providing And Fixing Powder Coated Aluminium (Minimum Thicknesss Of Powder Coating 50 Micron) Work For Doors, Windows, Ventilators And Partitions (Fixed Portions) With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Confirming To Is-733 And Is- 1285, Fixed With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E At Top, Bottom And Sides With Required Epdm Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified, Supplied And Fixed , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified, Supplied And Fixed , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Trusses, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And/Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.Gde-E-165 Complete All As Specified And Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Four (4) Coat Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed Note: To Be Executed For Provison Of Ridges And Hips, Valley Etc Complete All As Specifed And As Directed , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour For Machine Presssd Pre-Cast Concrete Interlocking Coloured Paving Block Of Glass Fibre Reinfoced Glossy Finished Vibro Compacted Any Shape And Size Confirming To Is-15658-2006 Of 60 Mm Thick, M-35 Grade To Match With Grey Cement And Pigment Etc Complete All As Specified And As Directed , Material And Labour For Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:6) Complete All As Specified And Directed. , Supply And Fix For Exterior Grade, Coloured Glossy Finish Rubber Pressed, Cement Concrete Designer Chequered Tiles Of Size 300Mm X 300Mm X 25Mm Thick Set, Jointed And Pointed In Neat Cement Slurry With Grey Cement And Pigment To Match The Shade / Colour / Matrix Of Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:6) Complete All As Specified And Directed. Etc Complete All As Specified And Directed. , Material And Labour For Double Charged Vitrified Ceramic Tiles Light Shade 9 To 10Mm Thick (Square/Rectangular) Area Of Each Tile Not Exceeding 0.36 Sqm, Laid In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15Mm Thick Screed Bed In Cm 1:6 Complete All As Specified And As Directed. , Material And Labour For Double Charge Vitrified Ceramic Tiles, Light Shade, 9 To 10Mm Thick (Square/Rectangular) Area Of Each Tile Not Exceeding 0.36 Sqm,, In Skriting Dado Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Colour Of Tiles, Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed. , Material And Labour Non Skid Coloured Ceramic Tiles 7 To 8Mm Thick, (Square/Rectangular) Area Of Each Tiles Exc 0.06 Sqm But Not Exc 0.11 Sqm As In Floors Set And Jointed In Cement Slurry And Pointed In White Cement Mixed With Colour Pigment To Match Existing Surfaces With 15 Mm Thick Screed Bed In Cement Mortar (1:6) Including Dismantling Of Old Unserviceable Tiles Complete All As Specified And Directed. , Material And Labour For Glazed Light Coloured/Printed Ceramic Tiles 450X300x7mm Thick In Vertical Surfaces Such As Skirting, Dado Etc Set And Jointed In Neat Cement Slurry, Pointed In White Or Coloured Cement To Match Colour Of Tiles, Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed. , Material And Labour For Non Skid Ceramic Coloured Tiles 7 To 8Mm Thick (Square / Rectangular) Area Of Each Tiles Exc 0.18 Sqm But Not Exceeding 0.38 Sqm In Floor Etc Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match With Coloured Tiles Over 15Mm Thick Screed Bed In Cement Mortar 1:6 Complete All As Specified And Directed. , Material And Labour For Non Skid Ceramic Coloured Tiles 7 To 8Mm Thick (Square / Rectangular )Area Of Each Tiles Exc 0.18 Sqm But Not Exceeding 0.38 Sqm On Vertical Surfaces As Skirting Etc Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match With Coloured Tiles Over 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For 100Mm Thick Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate ) As.In Floor Finishing Even And Smooth With Out Using Extra Cement Complete All As Specified And As Directed , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Supply Only Water Proofing Compound. , Material And Labour For Rendering 15 Mm Thick In Cm (1:4) On Fair Faces Of Brick Work Or Concrete Surface Finsihed Even And Smooth (Without Using Extra Cement) Etc Complete All As Specified And As Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Make: Berger Weathercoat Anti Dustt Or Equivalent Of Asian Paint Or Nerolac) Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Supply And Fix Sheet Glass 4.0 Mm Thick Ordinary Quality And Glazing With Oil Putty/ Wooden Beads/ Aluminium Window In Squares Not Exc. 1.00 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For Preparation Of New Or Previously Untreated Surface Of Wood Or Wood Based Materials Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer All As Specified. , Material And Labour For Preparation Of New Steel And Iron Surfaces Of Any Description, Over 10 Cm In Width Or Girth , Not Otherwise Described And Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Etc Complete All As Specified And As Directed , Supply Hoisting And Fix 500 Ltrs Rotational Moulded Polythene Water Storage Water Tanks Twin Layered Construction ( Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Duly Isi Marked, 20Mm Gi Light Grade Over Flow Pipe Approx Length 1.5M Long, 20Mm Gi Medium Grade Pipe For Wash Out Approx Length 2.00 M Duly Plugged At One End Shall Be Provided Including Dismantling The Existing Tank Complete All As Specified. , Supply Hoisting And Fix 1000 Ltrs Rotational Moulded Polythene Water Storage Water Tanks Twin Layered Construction ( Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Duly Isi Marked, 20Mm Gi Light Grade Over Flow Pipe Approx Length 1.5M Long, 20Mm Gi Medium Grade Pipe For Wash Out Approx Length 2.00 M Duly Plugged At One End Shall Be Provided Including Dismantling The Existing Tank Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
6.
Defence #11392755 Technical Bid
Tender for Material And Labour For Plain Cement Concrete 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundation ,Filling And Mass Concrete Complete All As Specified And Directed . , Material And Labour For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc , Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C-1 Using (20Mm Graded Stone Aggregate) As In Bed Blocks For Hold Fast,Coping Errection Of Posts Etc Complete All As Specified And Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) On Slabs Supported On Walls , Beams And Columns In Floors , Roofs,Landings,Balconies, Canopies Deck Slabs, And In Shelves And The Like Complete All As Specified And As Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) Chajja, Facia Etc And The Like Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C0 (Using 12.5Mm Graded Stone Aggregate) As In Filling The Hollow Portion Of Steel Frame Complete All As Specified And Directed. , Supply Only Water Proofing Compound. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specifed And Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour For Form Work On Flat Sides To Soffits Of Suspended Roof Slabs Not Exc 200 Mm Thick (Horizontal Or Sloping), Walls , Beams And Columns In Floors,Landings,Balconies, Canopies Deck Slabs, And In Shelves Rough Finished Surface Of Concrete All As Specified And As Directed. , Material And Labour For Form Work On Flat Sides To Chajja, Fins, Louvers, Fascia Etc Rough Finished Surface Of Concrete All As Specified And As Directed. , Refixing Wooden Or Aluminium Door Shutters Of Any Description Exceeding 1 Sqm But Not Exceeding 2 Sqm Each In The Same Opening After Taking Down, Easing And Adjusting Including Refixing Builders Hardware, Glass Etc As Required And Renewal Of Unserviceable Screws Concrete All As Specified And As Directed. , Supply And Fix For 2Nd Class Hardwood Plain, Solid, Straight Chowkhats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue, Pinned At Joints Complete All As Specified And Directed. , Supply And Fix Factory Made 30 Mm Thick Flush Shutter Solid Core Construction With Block Board Core & Plywood Face Panels Commercial Type On Both Sides Incl 5Mm Thick Teakwood Leaping Alround Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Factory Made Door, 35 Mm Thick, Glazed And Skeleton Shutters, Open Rebated And Prepated To Receive Glass Gauze Etc (With Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Materials And Revated Sash Bars Any Number , Edges Of Framing Plain Chemfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass In Door Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (A) Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Glazed And Skeleton Window Shutter 30Mm Thick, Divided Into Squares, With Plain, Chamfered Or Rounded, Mitred And Rebated Sash Bars, Any Numbers, To Receive Glass, Gauze, Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (B) Complete All As Specified And Directed. , Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Stapple Etc Concrete All As Specified And As Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised , Plate Type ,Stove Enameled Black , With Bright Bolt Not Less Than 12Mm Dia With And Incl Minimum Of 6 Bolts And Nuts ,Four On Bolt Plate And Two On Staple Concrete All As Specified And As Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 100Mm Etc Complete All As Specified And Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 75Mm Etc Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 150 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 100 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 200 Mm Long Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 150 Mm Long Complete All As Specified And Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised Sliding Door Bolts , With Hasp Staple (Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast-Aluminium Ally Complete All As Specified And Directed. , Supply And Fix Powder Coated Three Track Aluminium Sliding Window With Approved Make Of Following Extruded Section Of Anodised Glazed Shutter As Per Standard Engineering Practices Including All Other Accessories Complete Including 4.00 Mm Thick Tinted Glass Panes, Rubber Beading, Mosquito Proofing, Locking System Etc. Complete All As Specified And As Directed. (Refer Jindal Cat M-2014 ) Aluminium Sections : A Series (I) Shutter Bottom & Top :- 37.50 X 15 X 1.3 Mm Thick (20690) (Ii) Shutter Interlock :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iii) Shutter Side (Handle) :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iv) Frame Bottom :- 75 X 26 X 1 Mm Thick (20671) (V) Frame Top And Sides :- 75 X 26 X 1 Mm Thick (20672) , Supply And Fix Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) Or Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/Neoprene Gasket Required (Fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Material And Labour Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.,Complete All As Specified And Directed. , Material And Labour For Mild Steel Conforming To Fe 410-0 Or Fe 310-0 In Framed Work Such As Grills, Gratings, Etc With Ends Of Bars Shouldered And/Or Riveted Or Forged Into Spikes; Framed Guard Bars; Ladders; Railings And Similar Work Complete All As Specified And Directed. , Supply And Fix Box Type Steel Windows With Side Hung Shutters Both Mosquito Proof And Glazed Shutter Including Projecting Type Hinges With Steel Handle And Steel Peg Stay With Glazing Bars And 12 Mm Square Bar Or Ground Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And As Directed. , Supply And Fix Steel Ventilators With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. , Material And Labour For Mild Steel Tmt Bars 10 Mm Dia And Over Cut To Length, Bent To Shape As Required Including Cranking, Bending And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia As In Reinforcement Bar Complete All As Specified And As Directed. , Repairing Of Existing Mild Steel Rolling Shutter Of Any Description Or Any Size Including Replacement Of Damaged Mild Steel Laths, Repairing/ Replacement Of Side Guide Channels, Pipe Shaft, Springs, Ball Bearings, Locking Arrangements, Welding Work, Alingment And Smooth Operation, Including Necessary Nuts, Bolts, Oiling And Greasing, Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Atmospheric Classification Category 3,Four (4) Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed , Material And Labour For Pre- Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Plain Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Pattern Corresponding To Is 15965 : 2012 Of Durability Class 3, Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Having Yield Strength Of 550 Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified Complete All As Specified And As Directed. Note: To Be Executed For Provision Of Ridges And Hips. , Material And Labour For 12 Mm Thick Prelaminated Particle Board Bwp Type Melamine Finished (Both Side) For Fixing The Panel Of The Partition/Door Including Necessary Fittings, Gusket, Angle Cleats, Screw Etc Complete All As Specified And Directed. , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour For Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:4) Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm Thick, In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8Mm Thick Area Of Each Tile Exceeding 0.18 And N.Exc 0.38 Sqm In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exc 0.18 And N.Exc 0.38 Sqm , In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. , Material And Labour For Coloured/ Printed Glazed Ceramic Tiles 7Mm Thick Not Exc 0.15 Sqm In Area In Vertical Surfaces I.E. Dado, Skirting, Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, Laid Over And Including Screed Or Screed Bed 10Mm Thick In Cement Mortar 1:4, Complete All As Specified And As Directed. , Material And Labour For 75Mm Thick Cement Concrete 1:3:6 Type C-2 (Using 40Mm Graded Stone Aggregate ) As In Plinth Protection Complete All As Specified And Directed. , Material And Labour For 100Mm Thick Cement Concrete 1:2:4 Type B-2 (Using 40Mm Graded Stone Aggregate) As In Flooring, Hardstanding Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Material And Labour For 5Mm Thick Rendering On Fair Faces Of Brick Or Concrete Surface In Cm 1:3 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Ceiling Surface And Applying Three Coats Of White Wash Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Figured Glass, Pin Head Type And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For Preparation And Applying Two Coats Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Over A Coat Of Pink Primer Complete All As Specified And Directed. , Material And Labour For Preparation Of Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide On New Steel Surfaces , Over 10 Cm In Width Or Grith Not Other Wise Described Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 15Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 20 Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Hand Basin White, Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Pvc Waste Coupling And 32 Mm Dia Pvc Waste Pipe Including Fixing Of Tap, Waste Fitting Etc Complete All As Specified And Directed. , Supply And Fix In Repair Bib Taps With Wall Flange 15Mm Bore, Fancy Type, Quarter/Half Turn, Brass Chromium Plated, Long Body With Capstan Head And Cup Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Accessories Complete All As Specified And Directed. , Supply And Fix In Repair 125 Mm Dia, Chromium Plated Swivel Type Shower Rose With 195 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15Mm Bore Iron Pipe All As Specified And Directed , Supply And Fix In Repair Bath Wall Mixer With 15Mm Bore (Dia) Spout, Chromium Plated With Long Bend Pipe For Over Head Shower Including Flanges Complete All As Specified And As Directed. , Supply And Fix In Repair Pillar Taps, Cast Copper Alloy, With Capstan Heads, Fancy Type, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered ‘Hot Or ‘Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe 15 Mm Bore Complete All As Specified And Directed. , Supply And Fix In Repair Cp Stop Valve/Angle Valve 15 Mm Bore, Fancy Type Cromimum Plated With Long Shank And Cup (Concealed Type), High Pressure Crutch Or Butter Fly Handle Screwed Both Ends Screwed For Iron Pipe Or For Unions Complete All As Specified And Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 1000 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places With Fittings And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 500 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places Complete And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix Ball Valves 20Mm Bore Dia Of Pipe High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed (Minimum Weight 20Mm-210Gms). , Supply And Fix In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Supply And Fix In Repair Pvc Valve, Symphonic Action Type, Flushing Cistern 10 Liters Capacity Low Level White With Inlet ,Ball Valve ,Float And Handle Including Brocket Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Pvc (Swr) Pipes, Presure Rate Having 6 Kgf Single Socketed In Any Length With Rubber Ring Joints And Laid In Trenches As In Waste/Soil Pipe Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Complete All As Specified And As Directed. , Supply And Fix 75Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Or Floor Complete All As Specified And As Directed. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 75 Mm Bore Complete. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 110 Mm Bore Complete. , Supply And Fix, In Repair Vitreous China Wash Down Water Closet Of Orissa Pattern Size 580 X 440 Mm White With Integral Foot Rests Including Removing Filled Lean Concrete From Sunken Portion And Putting Of Lean Concrete After Treatment Of Sunken Slab, Connection To Trap And To Flushing Pipe Etc Complete And Making Good To Floor Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Down Water Closed Pan (Pedestal Pattern) With P Or S Trap White, Including Connection To Trap And Cistern, Flush Pipe Including White Plastic Water Closet Seat Cover, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Making Good Disturbed Surface Of Floor Complete All As Specified And Directed. , Supply And Fix In Repair Plastic Water Closet Seat Cover, White, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Fixed Wc Pan Complete All As Specified And Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Down Door Chowkhat With Shutter Area N-Exc 1.5 Sqm Each(Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Chowkhats Or Frames With Shutters Exc 1.5 Sqm But Not Exc 4 Sqm Each (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Of Any Description N. Exc 1 Sqm Each Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Any Description Area Exc 1 Sqm And N Exc 2 Sqm Each Complete All As Specified And Directed. , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete (Reinforcement Cut As Required To Facilitate Demolition) Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And As Directed. , Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Or Cement Lime Mortar , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Trusses Etc Complete All As Specified. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc. , Dismantling, Floor Hearth Or Wall Tiling Inclduing Cement Mortar Bedding And Removing Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc. 15 Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , Demolition And Breaking Up Drain Waste Pipes (Sgsw, Ac Or Rcc, Ci ) Of Internal Dia 75/110 Mm, Set In Cement Mortar In Any Position Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
7.
Housing Urban and Rular Development #11346479 Technical Bid
Tender for Construction Of Modular Ot Eye Under Old Sadar Hospital At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
8.
Housing Urban and Rular Development #11346477 Technical Bid
Tender for Construction Of Modular Ot (Eye) Under Sub Divisional Hospital At Madhupur Dist Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
9.
Housing Urban and Rular Development #11346476 Technical Bid
Tender for Construction Of Modular Ot (General & Gynae) At Chc Under Sarwan Block At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Multi Purpose Ot Table With C - Arm Compitable , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro-Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
10.
Railways #11312504 AOC
Supply Of four tender no clubbed , ward robe lock small with key (godrej multipurpose lock 9350). [ warranty period: 30 mo nths after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , sliding door hook lock with 3 keys lock for wooden sliding door (mortise lock) make/godr ej/victac /dimsvy. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , 8 inch glossy finish main door handle outside screw type make: goyal or similar . [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , ss 3/4 inch pipe curtain pipe bracket t type make-supreme / flyrail [ warranty perio d: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , ss 3/4 inch pipe curtain pipe bracket l type make-supreme / flyrail [ warranty perio d: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , quick adhesive 1c polyurethane adhesive direct glazing for industrial use with shore-a hard ness: approx. 65, tensile strength: approx. 8mpa, temperature range: 40 to 90 degree c, viscosity at 23 d egree c: 2500 to 4000pas, shelf life: 12 months; curing mechanism: moisture curing, accelerable, tube c ontaining 300/310 ml along with nozzles and half barreled caulking gun(20 nos.) of make/model: tekbon d pu 55 (310ml) cartridge of saint gobin or similar in pidilite/ sika flex. note: shelf life of the pro duct should have 6 months from the date of supply. [ warranty period: 30 months after the dat e of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , instant fix adhesive fast bonding (20-25 g) make- flex kwik of pidilite or similar inloctite/pol yfix/saintgobin. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , 4 inch aluminum oxide duracut flap disc (buffing pad) of grit 60 suitable to work with angle grinding machine. make: cumi/genric. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , supply and installation of roller blinds for window of size 8ft x 4ft, shade colour pattern to be matched with requirement of ra coach make: hippo or equivalent. [ warranty period: 30 months after th e date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , 8mm commercial plywood size 8ft x 4ft / make: kitply vista / urban plus silver [ warrant y period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , 6mm commercial plywood size 8ft x 4ft / make: kitply vista / urban plus silver. [ warran ty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , set of aluminium extruded sliding profile with roller assembly (one set consists of 8 feet leng th aluminium extruded profile and 2 nos. of roller assembly). [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , lavatory loose fittings: .1). towel ring round (acn-chr-1121bn) of jaguar make,2). towel rack( acn-chr-1181fhn) of jaguar make,3).soap dish holder (acn-chr-1131n) of jaguar mak e,4).soap dispenser with glass bottle(acnchr1135n) of jaguar make,5).tumbler holder (acnhr-1 141n) of jaguar make,6).toilet paper roll holder (acn-chr-1151n) of jaguar make,7).glass shelf 6 00mm long (acn-chr-1171n) of jaguar make or equivalent in cera/kohler. [ warranty period: 30 mont hs after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , 25mm commercial plywood size 8ft x 4ft / make: kitply vista / urban plus silver. [ warra nty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , 6 inch glossy finish brass handle make: jal/simax. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , 8 inch glossy finish main door handle. make: goyal/shapes [ warranty period: 30 month s after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , general purpose silicon sealent (280 to 310 ml cartridge) colour black,make-tek bond/loctit e/astral- resibond. note: shelf life of the product should have minimum 6 months from the d ate of supply. [ warranty period: 30 months after the date of delivery ] [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Contract Date: Jun 19, 2026 Contract Value : 2,630
Government Departments No of Bidders 1
11.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
12.
Power #11290475 Technical Bid
Tender For Overhauling Of U#5 Ash Handling Plant Bktpp- 2 Replacement/Repairing Of Clinker Grinder ( With Checking & Repairing /Replacement Of Feedsump/ Feedsump Adapter/ Nozzle, Combine Tube, Nozzle Tip, Nozzle Holder Etc. ) 3 Oh Of Feed Gate Along With Feed Gate ( Accessories. ) 4 Servicing/Replacement Of Hydroejector ( Along With Hydro Ejector Nozzle Tips, Throat, Inlet Piece, Nozzle Plate, Nozzle Inlet, Throat Increaser And Intermediate Wear Piece Etc. ) 5 Replacement Of Ba Hopper Looking Glass/ ( Looking Glass Assembly Including Repairing Of Cooling Line & Nozzle. ) 6 Servicing/Replacement Of Knife Gate V/V ( (200Nb/300Nb) At Economizer Hopper & At Discharge Of Clinker Grinder. ) 7 Servicing/Replacement Of 300Nb ( 250Nb Gate/Globe/Butterfly Valve. ) 8 Servicing/Replacement Of 100Nb/150Nb/ ( 200Nb Butterfly/Plug Valve/Gate/Globe Valve. ) 9 Servicing/Replacement Of 15Nb/25Nb/50Nb/ ( 65Nb/80Nb/32Nb Gate/Globe/Butterfly Valve/Ball Valve. ) 10 Trough Seal, Economiser Hopper, Eco ( Seal Box (Including Repair/ Replacement) & Its Drop Pipes And Ba Hopper Checking & Cleaning. ) 11 Oh Of U#5 Esp Area 12 Removal, Physical Inspection, Refitting ( And Replacement Of Esp Fluidising Tiles Including Frame Of Fluidising Tiles (If Required) And Its Pipe Fittings & Accessories To The Fluidising Line. ) 13 Checking, Removal, Refitting, Repairing/ ( Replacement Of Mhv Of Esp & Aph Hopper For Wet Cleaning Including Adapter (Esp Hoppers/Aph Hoppers/ Eco Hoppers).Change Of Seat/Disc Of The Valves As Per Condition. ) 14 Checking, Repairing/Replacement Of ( 10Inch/8Inch Tersg V/Vs. ) 15 Esp Hopper Inside Checking, Cleaning ( Repairing (If Required) And Change Of All Manhole Door Packing Gasket For Wet Cleaning. ) 16 Flushing/Cleaning Of Fluidising Air Line ( Including Replacement Of Damaged Pipe, And Valves, ) 17 Oh Of U#5 Fa Tower Area 18 Bag Filter/Cage Checking, Cleaning & All ( Bag Filter, Cage, Ventury Replacement With Pulse Jet Bar Checking And Repairing, Changing Of Pulsejet Hose And Tightening By Jubilee Clamp If Required. ) 19 Checking, Repairing/Replacement Of Dump ( Gate V/V Of Pct And Its Seal Including Repair Of Pct And Its Seat & With Fixing Of Ss Liner Plate, Dump Gate Gasket, Bearings, Bushes Etc Both For Top Gate And Bottom Gate As Per Requirement. ) 20 Checking, Repairing/Replacement Of Vent ( Equalising Valve Of Pct And Alv Including Change Of Short Piece. ) 21 Physical Inspection & Repairing Of Ish ( Including Change Of Fluidizing Tiles,Repair/ Replacement Of Frame And Checking And Cleaning/ Repair Of Fluidizing Lines And Its Valves And Servicing/ Replacement Of Prv. ) 22 Checking, Repairing/Replacement Of Alv ( Rsv Including Fluidizing Tiles And Repairing/Replacement Of Body Pad And Spool Piece. ) 23 Disposal Of Ish Ash Through Tractor ( To The Ash Dumping Yard. ) 24 Repairing/Replaceemnt Of Collector Tank ( Cylindrical And Conical Portion Including Checking & Replacement Of Impingement Plate, Checking And Clearing Of Seal Box With Minor Repair If Required. ) 25 Repairing/Replaceemnt Of Wetting Head ( Including Checking & Replacement Of Nozzle, Inlet Section, Gaskets, Tail Piece, Outlet Section Etc. ) 26 Oh Of Air Washer (Dry / Wet) Including ( Checking & Replacement Of Nozzles, Gaskets Etc. Or Replacement Of Whole Assembly ) 27 U#5 Pipeline & Fabrication Job 28 Rotation/Replacement Of 8 Inch/10 Inch ( Ci/ Ms Pipe Line Including Bend/Lateral/Spool Piece & T-Joint Below Esp Hopper & Up To Fae Tower, Line Alignment Checking, Repairing/Erection Of Damaged Support, Coupling, Gasket Replacement Etc. ) 29 Replacement Of Vacuum Line, Ms, Ish Vent ( To Esp Duct Ms 200 Nb ) 30 Replacement Of Dry Air Washer Drain Line ( Bahp Valve Station Pipe Line Up To Hydro Ejector Inlet (Ms 150 Nb) ) 31 Replacement Of Ish, Alv Fluidising Line, ( Sealing Line At Bacr, Seal Water Line At Vacuum Pumps, Eco Water Flushing Nozzle Connection (Ms 15 Nb, 25 Nb, 32 Nb, 40 Nb, 50 Nb) ) 32 Replacement Of 8Inch, 10Inch Drc Pipe 33 Replacement Of 10Inch Ci/Drc ( Bend, Tee Etc. ) 34 Fabrication And Erection Of 150Nb,200Nb, ( 250Nb, 300 Nb Ms Bends With Complete Welding. ) 35 Fabrication And Erection Of 32Nb, 40Nb, ( 50Nb, 65Nb, 80Nb, 100Nb , 125 Nb Ms Bends With Complete Welding. ) 36 Replacement Of Eco Slurry To Bah ( (Ms, 300 Nb), Hp & Lp Line In Bah Area, Collection Tank Drain And Overflow Line (Ms 200 Nb, 250 Nb,300 Nb) ) 37 Replacement Of Bah Area Hp Jetting ( Including Inside Bah Jetting Line With Fitting Of Jetting Nozzle, Lp M/U, Trough Seal M/U, Trough Seal Drain (Ms 100 Nb/80 Nb) ) 38 Replacement Of Hp Flushing Line Inside ( Bah With Cutting Of Opening Of Jetting Nozzle, Outside Enclosure Pipes (Ms, 150 Nb) ) 39 Replacement Of Refractory Cooling Header ( Inside And Outside Bah With Cooling Nozzle Inside Bah Area, Individual Connection From Outside Bah Header To Inside Bah Header, Looking Glass Cooling Supply Line, Pct, Alv Vent Lines (Ms 65 Nb, 50 Nb, 25 Nb) )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
West Bengal View Result →
13.
Health and Family Welfare #11289913 AOC
Tender for Annual Contarct Of Supply Of General Items In Dh Morena , General Items , Bmw Waste Bin With Swipe Cover 80Ltr All Colour, Bmw Waste Bin With Swipe Cover 100Ltr All Colour, Bmw Wastebin With Swipe Cover 120Ltr All Colour, Bmw Waste Bin With Swipe Cover 10Ltr All Colour, Bmw Waste Bin With Swipe Cover 20Ltr Colour, Bmw Waste Bin With Swipe Cover 40 Ltr All Color , Bmw Waste Bin Foot Opreted 10 Ltr All Color , Bmw Waste Bin Foot Opreted 20 Ltr All Color , Bmw Waste Bin Foot Opreted 40 Ltr All Color , Bmw Waste Bin Foot Opreted 60 Ltr All Color , Bmw Waste Bin Foot Opreted 80 Ltr All Color , Bmw Waste Bin Foot Opreted 100 Ltr All Color , Bmw Waste Bin Foot Opreted 120 Ltr All Colour, General Watse Bin With Swipe Cover 10 Ltr All Colour, General Watse Bin With Swipe Cover 20 Ltr All Colour, General Watse Bin With Swipe Cover 40 Ltr All Colour, General Watse Bin With Swipe Cover 60 Ltr All Colour, General Watse Bin With Swipe Cover 80 Ltr All Colour, General Watse Bin With Swipe Cover 100 Ltr All Colour, General Watse Bin With Swipe Cover 120 Ltr All Colour, Bmw Poly Bag 10 Kg All Colour, Bmw Poly Bag 20 Kg All Colour, Bmw Poly Bag 40 Kg All Colour, Bmw Poly Bag 60 Kg All Colour, Bmw Poly Bag 100 Kg All Colour, Bmw Poly Bag 120 Kg All Colour, Led Screen 21.5 Inch Dell/Hp/Acer/Samsung /1 Year Warranty , Led Tv 32 Inch Dell/Hp/Acer/Samsung /Lg 1 Year Warranty Including Installation Charges , Led Tv 42 Inch Dell/Hp/Acer/Samsung /Lg 1 Year Warrantyincluding Installation Charges , Led Tv 56 Inch /Dell/Hp/Acer/Samsung /Lg 1 Year Warranty Including Installation Charges , Led Tv 65 Inch Dell/Hp/Acer/Samsung /Lg 1 Year Warranty Including Installation Charges , Tablet 8Gb Ram 128 Gb Rom (Lenevo/Samsung) , Desk Top Computer I-5 13 Th Generation Or Higher 8 Gb Ram 1 Tb Hard Disc 24 Inch Screen With 1080X1920 Or Higher Resolution Os Window 11 Home /Commercial ,Processor Speed 2.5Gh Or Higher Processor Quadracore Including Installation Charge 3 Year Onsite Warranty (Hp/Lenevo/Acer) , Laptop I-5 13Th Generation 8 Gb Ram 1 Tb Hard Disc Window 11 Dispplay15.6 Reosultion 1920X1080 Or Higher Processor Speed 2.5 Gh Or Higher Including 3 Year Onsite Warranty , Laptop I-5 12Th Generation 8 Gb Ram 1 Tb Hard Disc , Dura Cell A Size , Dura Cell Aasize , Dura Cell Aaa Size , Glucometer Cell , Lyrngoscope Cell , Biometric Device L1(Morpho/Mantra) , Iron Rack 3X6 Feet All Side Cover , Iron Rack3x 4 Feet All Side Cover , Iron Almirah 6 Feet 4 Shelves Locker Weight Minimun 65 Kg , Almirah 4 Feet With Locker Weight Minimun 40 Kg , Narcotic Double Lock Almirah 24X16x8 Inch , Iron Almirah Glass Door 3X6ft Shalves Min 60Kg Weight , Oxygen Key Complete , Wooden Stool , Pateint Stool Revolving , Table Cloth , Table Glass , Fastner 6 Inch , Fastner 8 Inch , Fastner 10 Inch , Emergency Light Chargable 40 Watt , Emergency Light Chargable 80 Watt , Emergency Light Chargable 100 Watt , Plastic Chair Weight 6 Kg , Office Chair Non Revolving Non Tilted , Office Chair Rovolving , Executive Office Chair , Gyser , Pen Drive 64 Gb Hp , Box File , Battrey 80 annual periodical maintenance Min 2 Year Waranty , Battrey 120 annual periodical maintenance Min 2 Year Waranty , Battrey 150 annual periodical maintenance Min 2 Year Waranty , Battrey 200 annual periodical maintenance Min 2 Year Waranty , Inveter 12 V Min 2 Year Waranty , Inveter 24 V Min 2 Year Waranty , Ups Inveter For Computer , Ecg Eletrode( Bpl ) , Ecg Eletrode( Bpl ) , Ecg Cable (Bpl) 2Channle , Ecg Cable (Bpl) 4Channle , Ecg Cable (Bpl) 6Channle , Ecg Cable (Bpl) 8Channle , Ecg Cable (Bpl) 12Channle , Ecg Chest Electorde (Bpl) , Strecher Wheel Heavy Quality , Coolar 4 Feet Iron Body 4 Feet Copper Wiring With Crompton Motor With 1 Year Warranty , Coolar 6 Feet Iron Body Copper Wiring With Crompton Motor 1 Year Warranty , Portable Ac Coolar Small Size Honey Comb With One Year Waranty , Portable Ac Coolar Big Size Honey Comb With One Year Waranty , Motor For Duct Cooling System 18 Inch 900 Rpm , Motor For Duct Cooling System 18 Inch 1440Rpm , Motor For Duct Cooling System 8 Inch , Motor For Duct Cooling System 10 Inch , Wall Mounted Fan 22 Inch , Padistial Fan , Keyborad For Desktop , Mouse For Desktop , All In One Printer , Laser Printer 3 In One , Both Side Laser Printer , Both Side Laser Printer Color , Printer Balck And White , Colore Printer Ink Jet , Scanner , Split Ac 1.5 Ton With Stabliser 4/5 Star Rating Copper Wiring ,With 10 Ft Pipe Stand For Outdoor Unit Compressor Warranty 05 Yearincluding Installation Charges (Hitachi/Diakin/Carrier/Voltas/Lg) , Split Ac 2 Ton Copper Wiring ,With 10 Ft Pipe Stand For Outdoor Unit Compressor Warranty 05 Year Including Installation Charges(Hitachi/Diakin/Carrier/Voltas/Lg) , Window Ac 1.5 Ton With Stabilizer Star Rating 4-5 Copper Wiring Compressor Warranty 05 Year Including Installation Charges(Hitachi/Diakin/Carrier/Voltas/Lg) , Window Ac 2 Ton With Stabliser Star Rating 4-5 Copper Wiring Compressor Waranty 05 Year Including Installation Charges(Hitachi/Diakin/Carrier/Voltas/Lg) , Refrigrator 165 Ltr 3-5 Star Rating Copper Wire Compressor Waranty Minminum 03 Year , Refrigrator 190 Ltr 3-5Star Rating Copper Wire Compressor Waranty Minminum 03 Year , Refrigrator 220 Ltr 3-5 Star Rating Copper Wire Compressor Warranty Minminum 03 Year , Refrigrator 250 Ltr 3-5 Star Rating Copper Wire Compressor Warranty Minminum 03 Year , Distamper Paint In All Color 1 Ltr , Distamper Paint In All Color 5Ltr , Distamper Paint In All Color 10Ltr , Distamper Paint In All Color 20 Ltr , Enamel Paint In All Color 1 Ltr , Enamel Paint In All Color 5 Ltr , Enamel Paint In All Color 5Ltr , Enamel Paint In All Color 10 Ltr , Enamel Paint In All Color 20 Ltr , Thinner 1 Ltr , Lime Stone Powder Per Kilogram , White Putti Per Kilogram , Brush 4 Inch For Paint , Roller Bursh Small , Roller Bursh Big , Computer Table , Lock 12 Lever (Link) , Lock 8 Lever (Link) , Digital Wall Clock With Date And Temp , Sleeper 6,7,8,9 And 10 Number , Rexine Cover For Hospital Mattress All Size , Labor Table Rexine Cover , Table Glass , Low Pressure Suction Machine Adult , Low Pressure Suction Machine Pediatric , Baby Weight Machine , Room Thermometer , Machanical Weight Machine Up To 1 Kg , Machanical Weight Machine Up To 2 Kg , Machanical Weight Machine Up To 5 Kg , Room Heater /Blower 2000 Watt Copper Wiring Body Plastic/Matel 01 Year Warranty , Post Mortem Kit With All Tool , Candle Big Size , Welding Machine With All Accessories For Commercial Use , Three Bucket Trolly With Bucket With Iron Frame , Fire Extinguisher A Type , Fire Extinguisher B Type , Fire Extinguisher C Type , Fire Extinguisher K Type , Fire Ball , Screw Driver Small Size , Screw Driver Medium Size , Screw Driver Big Size , Plass Small Taparia Brand , Plass Big Taparia Brand , Taster , Chota Hathoda , Bada Hathoda , Electric Gloves Heavy Duty , Gum Boot , Safty Helmet Heavy Duty , Iron Stool 7 Foot , Iron Stool 15 Foot With Wheel , Bamboo Ladder 15 Feet , Bamboo Ladder 20 Feet
Contract Date: Jun 30, 2026 Contract Value : 40.00 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Madhya Pradesh View Result →
14.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
16.
Educational and Research Institute #11273270 Technical Bid
Tender For Civil Work At Mgsss, Ratanpura Block Rajgarh- 1 Part A Civil Work 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 P.C.C. In Foundation Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:4 Coarse Sand :8 Gradeed Stone Aggregate 40 Mm Nominal Size). 4 Brick Masonry With F.P.S. Bricks Of Class Designation 75 In Foundation And Plinth With Bricks Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) 5 Dpc:-Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required Excluding The Cost Of Centering, Shuttering And Reinforcement . M20 Grade Nominal Mix/Design Mix. 6 Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc. Good Soil Of Earth 7 Brick Work In Super Structure Upto Five Storey With Selected Bricks Of Class Designation 75 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10Mm. Wide 12Mm. Deep Complete In Cement Mortar 1:6. Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Add Extra Over Item Of Brick Work With Class Designation 100 In Substitution Of Class Designation 75 : 8 Pillar Masonary :-Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And All Sides Are Free 9 Stone Kharanja: Rr Dry Stone Kharanja Under Floor 10 Lintel Beams:-Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( As Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 11 Slab & Beam:-Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( As Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 12 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. 13 Steel Reinforcement:-P/F Reinforcement For Rcc Work Including Straightening,Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Upto Floor Five Leve Tmt Bars (Conforming Of Relevent Is Code). 14 Door Frames:- Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M), Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Angle Iron (40X40X5Mm. @ 3 Kg/M) 15 Doors:-Providing And Fixing M.S. Sheet 1 Mm Thick Double Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint. Add Extra For Double Leaf Shutters 16 Glazed Window:Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13X3Mm, 10Cm. Long Embedded In Cement Concrete Block 15X10X10Cm. Of 1:3:6 (1Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :Partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] 17 Wire Gauge Supplying & Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150 Mm Distance. 18 Guard Bars: P&F Square Bars Or Other Flat Welded To Window/Ventilators Etc. 19 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 20 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab From 2001 To 5000 Sqcm 21 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish : 12Mm Thick. 22 External Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 20 Mm Thick 23 Plaster(Ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1 Cement: 3 Fine Sand) 24 Black Board : Plaster On New Surface On Wall In Cement Sand Mortar 1:3 Including Raking Of Joints Etc. Complete Fine Finish: 12 Mm Thick 25 Grading Roof For Water Proofing Treatment With Water Proffing Compound: Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) 26 Gola:- Providing Gola 75Mm X 75Mm In Cement Concrete 1:2:4(1 Cement: 2 Coarse Sand: 4 Stone Aggregate 10 Mm And Down Gauge) Including Finished With Cement Mortar 1:3(1 Cement: 2 Fine Sand) As Per Standard Design. 27 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: New Work (Two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. 28 Inernal Finishing: Distempering With Dry Distemper Of Approved Brand Shade ( Two Or More Coats ) Of Required Shade New Work , Over And Including Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 29 Exterior Finishing: Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 30 Painting On Doors, Windows & Ramp Raling :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). 31 Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 32 For Rain Water-P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 33 For Rain Water-P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110Mm Dia 34 Pipe Clip 110 Mm Dia 35 Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300Mm Confirming To Code Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). 36 Part B Electrical Work 37 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Short Point (Up To 3 Mtr.) 39 Medium Point (Up To 6 Mtr) 40 Long Point (Up To 10 Mtr) 41 Fan Point 42 Short Point (Up To 3 Mtr.) 43 Medium Point (Up To 6 Mtr) 44 Long Point (Up To 10 Mtr) 45 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsron Board 46 S&F Following Sizes (Dia.) Of Isi Marked ( Is:9537 P - Ii ) Rigid Steel Conduit With Wall Thickness According To Is Specified Along With Isi Marked (Is:14768 P-Ii 2003) Accessories In Recessed Using Saddles, Clamps, Fasteners, Pvc Bushes, Check Nuts, As Required Including Cutting Jhiris In The Wall And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 25 Mm 47 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 48 1 X 1.5 Sq. Mm 49 2 X 1.5 Sq. Mm 50 2 X 2.5 Sq. Mm 51 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6 A To 32 A Rating 52 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Metal Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 8 Way (8+2) 53 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Minimum Lumen Output 1300 Lm 54 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity >99.7 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6.0 Sq. Mm 4 Core 55 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 3 Star Rated (Service Value >=5.0 To 56 Providing & Fixing Of Isi Marked (Is:371) 6 Amp Surface Type 3 Pin Ceiling Rose With Cm/L No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screws Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 57 Providing & Fixing Of Isi Marked (Is:1258) Batten/Angle Lamp Holder With Cm/L No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 59 P & F 1.2 Mm Thick G. I. / M .S. Sheet Boxes Duly Finished With Two Coats Of Red Oxide And With Earthing Terminal Of Following Sizes (Nominal Size) In Recessed/Surface As Required.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 175Mm X 100Mm X 60Mm 60 P & F Paper Phenolic Resin Bonded Laminates Confirming To Is : 2036 - 1995 For Boxes/ Frames Including Making Holes For Switches Etc, With Brass Screws, Washers/ Zinc Plated Nut And Bolts As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 3.0 Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
17.
Tourism #11266721 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Jul 03, 2026 Contract Value : 5.42 Crore
Government Departments No of Bidders 2
18.
Communications and Information Technology  #11254536 AOC
Bids Are invited for Workstation - Workstation Size 1200 X 600 X 750Mm With 1200Ht. 60Mm Panel Base Aluminium Front Partition, Provide 25Mm Thick Prelaminated Particle Board Top All Exposed Edges Of Top Covered By 2Mm Pvc Edge Bend By Through Feed Machine, Provide Fix Pedestal With 3 Drawer (2 Pencil Drawer+1 Filling Drawer, Provide Combination White And Soft Board In Front Partition And Provide Cable Duct With Proper Cut For Electric Switch Plate, Cover Of Cable Duct Properly Hanged And Lock In Front Partition By Hardware Fittings. Provide Glass Panel Partition Above Table Top Fitted By Holders. Provide End Partition At End Of Each Row With Glass Tiles Above Table Top. Provide Metal Keyboard Tray On Each Seat. Powder Coat And Lamination Shade As Per Client Choice , Workstations - Workstation Size 1100 X 600 X 750Mm With 1200Ht. 60Mm Panel Base Aluminium Front Partition, Provide 25Mm Thick Prelaminated Particle Board Top All Exposed Edges Of Top Covered By 2Mm Pvc Edge Bend By Through Feed Machine, Provide Fix Pedestal With 3 Drawer (2 Pencil Drawer+1Filling Drawer, Provide Combination White And Soft Board In Front Partition And Provide Cable Duct With Proper Cut For Electric Switch Plate, Cover Of Cable Duct Properly Hanged And Lock In Front Partition By Hardware Fittings. Provide Glass Panel Partition Above Table Top Fitted By Holders. Provide End Partition At End Of Each Row With Glass Tiles Above Table Top. Provide Metal Keyboard Tray On Each Seat. Powder Coat And Lamination Shade As Per Client Choice , Office Table With Side Unit - Provide & Fixing Of Table 1500X750x750mm , Provide 25Mm Thick Prelaminated Particle Board Top, Provide Gable End And Modesty Panel Of 18Mm Thick Prelaminated Particle Board All Table Fitted By Modular Fittings. All Exposed Edges Covered By 2Mm Thick Pvc Edge Bend .Provide & Fixing Of Side Unit, Size 900X450x750mm Top Side And Door/Drawer Front Made By 18Mm Thick Prelaminated Particle Board . Unit Have Two Drawer Below Table Top And S
Contract Date: Ref. Documents Contract Value : 19.75 Lakh
Government Departments No of Bidders 24
19.
Housing Urban and Rular Development #11229363 AOC
Misc. Repairs And Other Civil Works Of Tiles, Doors, Windows,Wooden Flooring, Shed And Internal And External Painting In C.M. Bunglow Civil Line Nagpur.(Only For Society).-= 1 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand 2 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. 4 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 1190 to 1202 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring 5 Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete. 6 Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 7 Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 8 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 9 ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. 10 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 11 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 12 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 14 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete 15 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete.b) Granite 16 Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. 17 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 18 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc.as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge. 19 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 20 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 21 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. 22 Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed includingthrowing the unserviceable materials out side etc. complete. 23 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 24 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 25 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 26 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 27 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 28 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 29 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 30 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 31 Providing and fixing C.P. BIB cock with wall flange jaquar or equivalent make continental (CAT.NO. CON-047) including necessary sockets/ union nut etc. complete. 32 Providing and fixing C.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental (CAT.NO. CON-059) including necessary sockets/union nut etc. complete. 33 Providing and fixing C.P. pillar cock long neck with aerator jaquar or equivalent make continental (CAT.NO. CON -021) including necessary sockets/union nut etc. complete. 34 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 35 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 36 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 37 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets & necessary fittings and tested as per municipal requirement etc. complete. 38 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres 39 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 40 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. 41 Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover etc. complete. 42 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.NO. CON-273 UPR) including necessary sockets/union nut etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 45 Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 46 Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. 5 km leadloading unloading 47 Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. 48 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) 49 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 kg) 50 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kg/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 51 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 52 Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 mm thick and 75 mm wide with panel insert of 12 mm thick particle Board with one approved coloured Laminated Face on one side 1.5 mm thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 53 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). 54 Providing and fixing C.P. 2 Way BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. 55 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 57 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 58 Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete 59 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessaryscrew, making proper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-chareg. 60 ProvidingHydrulic door closer .... 61 ProvidingSuper Jet Spry with flange 2 in 1 faucet 1.50 mtr long. 62 Providing Skilled plumber with tools as per direction of Engineer Incharge. 63 Providing skilled carpentor with tools as per direction of Engineer Incharge 64 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface and including scraping etc. complete. 65 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 66 Providing and applying single coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 67 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 68 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 69 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 70 Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete 71 Providing curtain rod dropping with channel MAC brand of superiar quaility including all required material labour etc complete. as directed by engineer incharge......... 72 Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and maketo door shutter including removing existing the same inoriginal position making prope radjustment for smooth operation etc. complete as per sample approved by Engineer incharge. 73 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and maketo door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. 74 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and maketo door/window shutter including removing existing the same inoriginal position making proper adjustment for smooth operationetc.complete as per sample approved by Engineer in-charge. 75 ProvidingHandle 150 mm Chromium plated (Rounded shape). 76 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 77 Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. 78 Providing & fixing Decorative wall paper superior quality including adhesive to fix at wall etc complete. as directed by engineer incharge......... 79 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 80 Providing & fixing Mica laminate as per ISI 0.1 mm thick etc complete...... 81 Providing & fixing 19 mm plywood 710 bwp full red core with report etc complete...... 82 Providing & fixing 12 mm plywood 710 bwp full red core with report etc complete...... 83 Providing & fixing teak wood batterns 50x25 mm etc complete...... 84 Providing & fixing plain glass 6 mmetc complete...... 85 Providing & fixing teak wood batterns 70x45 mm etc complete...... 86 Providing & fixing door stopper etc complete...... 87 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 88 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 89 Providing and Laying wearing laminate wooden or eqiuvalent flooring 8 mm thick in attractive strips for conference hall. 90 Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kg/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 91 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 92 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with allnecessaryfixturesandfittingetc.complete.(SampletobefinalbyEngineerIn-charge prior execution of work) 93 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 94 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 95 Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 96 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 97 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. 98 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. 99 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 100 BASIC TEST OF CEMENT :-Standerd Consistancy Fineness, Specific Graviti, Setting Time (Initial & final, Compressive Strength, Soundness. 101 BASIC TEST OF BRICK :-Water Absorption, (Set of 5 Brick), Comoressive Strength (Set of 5 Blocks), Efflorescence (Set of 5 Bricks) 102 CERAMIC TILES/ VITRIFIED TILES :- Water Absorption, Modules of Rapture (Set of 6 Tiles) 103 BASIC TEST OF C. C. TILES. :-Flexural test(Set of 6 tiles) Water Absorption,(Set of 6 tiles) Resistance to wear(Set of 6 tiles). 104 BASIC TEST OF Fine Aggregate Fineness Modulus (Sieve Analysis) silt and cley content..... 105 BASIC TEST OF Concrete Paving Block :- Compressive strength, Water Absorption, (Set of 8 Blocks ) 106 BASIC TEST OF STONE / RUBBLE/ Crushing Value/Compressive strengh, Water 107 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction materials for whichroyalty is necessary.(Royalty charges will be paid to contractor after sumbitting valid documents of revenue authority)Royalty for naturalSand (Royalty + Surcharges 2% & Distt. mineral foundation cess 10%)
Contract Date: Jun 04, 2026 Contract Value : 15.18 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
20.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
22.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
23.
Educational and Research Institute #11191269 AOC
Tender For Supply And Installation Of Furniture At Library And Computer Building. , Furniture , Library Chair -01 -Seat Size: 50.0Cm. (W) X 48.0 Cm. (D) -Back Size: 53.0 Cm. (W) X 39.0Cm. (H) -Injection Moulded Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ & Hardness 16 Kgf. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -M.S. Powder Coated Frames (Dft 50 Microns) For 4 Leg Chairs -M. S Pipe Dia 25Mm (Vendor To Submit Powder Coating Laboratory Test Certificate) -Glass Filled Polypropylene Armrest With The Tubular Frame. -Vendor Should Submit Detail Shop Drawings With All Dimensions. , Office Chair Seat Size- 53.5 Cm. (W) X 51.0 Cm. (D), Of 1.5 Cm Thickness Plywood Preferably Hot-Pressed, Furnished With Fabric Covers -Mesh Back Size- 51.0 Cm. (W) X 70.0 Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Glass Filled Nylon Armrest With The Tubular Frame Of 6 Cm Hight(Adjustable) -Center Tilt Synchro Mechanism With Seat Slide & Multi Lock, Revolving 360° -Head Rest Sub-Assembly With Hight Adjustment Up To 4 Cm. -Pneumatic Height Adjustment Of 9.5Cm, Pedestal Assembly Of Polished Aluminium With Twin Wheel Injection Moulded Soft Castors Of Nylon With Pu Lining, Having Up To 6 Cm Wheel Diameter. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation Chair Seat Size- 53.5 Cm. (W) X 51.0 Cm. (D), Of Thickness 1.5 Cm Plywood Preferably Hot-Pressed, Furnished With Fabric Covers. -Mesh Back Size- 51.0 Cm. (W) X 70.0 Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Glass Filled Nylon Armrest With The Tubular Frame Of 6 Cm Hight(Adjustable) -Center Tilt Synchro Mechanism With Seat Slide & Multi Lock, Revolving 360° Anti-Shock Mechanism. -Pneumatic Height Adjustment Of 9.5Cm, Pedestal Assembly Of Polished Aluminium With Twin Wheel Injection Moulded Soft Castors Of Nylon With Pu Lining, Having 6 Cm Wheel Diameter. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Conference Chair Seat Size: 49.0 Cm. (W) X 51.4 Cm. (D) Of Thickness 1.2 Cm Plywood Preferably Hot-Pressed, Furnished With Synthetic Leather Over Moulded High Resilience Polyurethane Foam. -Mid Back Size: 51.6 Cm. (W) X 65.7 Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 55 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Chrome Plated Up-Down Adjustment Armrest Of 8 Steps. -360° Revolving Type Front Pivot Synchro Mechanism, 4-Position Locking With Anti-Shock Feature, Tilting Ratio Of 1:2, Single Point Control. -Back Height Adjustability, Adjusted In 5 Positions. -Pneumatic Height Adjustment Of 10Cm, Pedestal Assembly (Pedestal- 65 Cm, Pitch-Center Dia. 75Cm) Of Polished Aluminium With Twin Wheel Injection Moulded Castors. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Study Chair With Writing Pad Seat Size : 50.0Cm. (W) X 48.0 Cm. (D) Furnished With Fabric Covers And Moulded Polyurethane Foam -Back Size : 53.0 Cm. (W) X 39.0Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -M.S. Powder Coated Frames Dia 25Mm (Dft 50 Microns) For 4 Leg Chairs With Glass Filled Polypropylene Shoe (Vendor To Submit Powder Coating Laboratory Test Certificate) -The Full Desklet Made Of 1.3 Cm. Thick, Compact Laminate Board. Having Front And Back Adjustment Of 4 Cm -Outer Dimension 59.5±0.1Cm. (W) X 29.0±0.1Cm -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Conference Table With Seating Capacity Of 18Seats 2 Str Main - 1350 X 600 X 740 - 2 Nos. -2 Str Shared - 1350 X 600 X 740 - 2 Nos. -2350W - 2350 X 850 X 740 - 2 Nos. -Work Surface Made Of 25Mm Thick Pre-Laminated Twin Board With A High-Quality Wood Matching 2 Mm Thick Pvc Lipping; Plastic Access Flap Is Provided For Easy Access To Wires And Cables -Under Structure Consists Of 18Mm Thick Pre-Laminated Twin Board Wood Matching 2 Mm Thick Pvc Lipping -Modesty Panel-Made Of 18Mm Thick Pre-Laminated Twin Board Of Wood Matching 2 Mm Thick Pvc Lipping -Powder Coated Accent Metal Strip Provided Below Work Surface Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent Steel, Epoxy Polyester Powder Coated (Dft 40-60 Microns). (Vendor To Submit Powder Coating Laboratory Test Certificate) -Wire Management- An Array Of Panels Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent, Epoxy Polyester Powder Coated (Dft 40-60 Microns) Is Used For Flow Of Wires And Cables. Provision To Mount 6 Module Electric Switch Plate Is Provided Below Worktop. Cut-Out On Top With Two-Piece Injection Moulded Plastic Part Polymer Component Is Fitted To Pull Out Audio, Video Cables Onto Worktop And Connect Devices Charger To Power Socket Below Worktop. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Conference Table With Seating Capacity Of 30 Seats 2 Str Main - 1350 X 600 X 740 - 2 Nos. -2 Str Shared - 1350 X 600 X 740 - 8 Nos. - 2Str -2350 X 850 X 740 - 2 Nos. -Work Surface Made Of 25Mm Thick Pre-Laminated Twin Board With Wood Matching 2 Mm Thick Pvc Lipping; Plastic Access Flap Is Provided For Easy Access To Wires And Cables -Under Structure Consists Of 18Mm Thick Pre-Laminated Twin Board Of High-Quality Wood Matching 2 Mm Thick Pvc Lipping -Modesty Panel-Made Of 18Mm Thick Pre-Laminated Twin Board Of High-Quality Wood Matching 2 Mm Thick Pvc Lipping -Powder Coated Accent Metal Strip Provided Below Work Surface Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent Steel, Epoxy Polyester Powder Coated (Dft 40-60 Microns). (Vendor To Submit Powder Coating Laboratory Test Certificate) -Wire Management- An Array Of Panels Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent, Epoxy Polyester Powder Coated (Dft 40-60 Microns) Is Used For Flow Of Wires And Cables. Provision To Mount 6 Module Electric Switch Plate Is Provided Below Worktop. Cut-Out On Top With Two-Piece Injection Moulded Plastic Part Polymer Component Is Fitted To Pull Out Audio, Video Cables Onto Worktop And Connect Devices Charger To Power Socket Below Worktop. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Two-Seater Sofa Seat Is Made Up Of Pu Foam In Density 28 Kg/Cu.Mtr With An Additional Top Layer Of Super Soft Pu Foam Furnished With Fabric Or Leatherette.(Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Back Is Made Up Of Pu Foam In Density 28 Kg/Cu. Mtr With Two Additional Top Layers Of Super Soft Foam Furnished With Fabric Or Leatherette. -Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Leg Assembly Is A Welded Assembly Made In Stainless Steel Tube & Plate With Plastic Endcap Of 146 X 90 X 85.5 Cm With Seat Height Of 45 Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Three-Seater Sofa Seat Is Made Up Of Pu Foam In Density 28 Kg/Cu.Mtr With An Additional Top Layer Of Super Soft Pu Foam Furnished With Fabric Or Leatherette. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Back Is Made Up Of Pu Foam In Density 28 Kg/Cu. Mtr With Two Additional Top Layer Of Super Soft Foam Furnished With Fabric Or Leatherette. -Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Stainless Steel (Grade Ss 202) O Equivalent Grade Tube Welded Leg Assembly With Plastic Endcap Of 206 X 90 X 85 Cm Seat Height 45Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions. , One Seater Sofa Seat Is Made Up Of Pu Foam In Density 28 Kg/Cu.Mtr With An Additional Top Layer Of Super Soft Pu Foam Furnished With Fabric Or Leatherette. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Back Is Made Up Of Pu Foam In Density 28 Kg/Cu. Mtr With Two Additional Top Layers Of Super Soft Foam Furnished With Fabric Or Leatherette. -Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Stainless Steel (Grade Ss 202) Or Equivalent Grade Tube Welded Leg Assembly With Plastic Endcap Of 86 X 90 X 85 Cm Seat Height 45Cm. -Vendor Should Submit Detail Shop Drawing With All Dimensions. Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Stainless Steel (Grade Ss 202) O Equivalent Grade Tube Welded Leg Assembly With Plastic Endcap Of 86 X 90 X 85 Cm Seat Height 45Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Mobile Compactor Storage Unit-01 3 Bay Drive Type Compactors With 3 Bay Sd - 1 No, 3 Bay Td - 1 No, 3 Bay Sl - 1 No. 3 -Size Of Compactor 2361H Mm X 915 W Mm X 457D Mm, 3 Bay Channel 2400 Mm - 3 No, 3 Bay Channel 800 Mm - 3 No. -Main Body: Rigid Knock Down Construction Made Of 0.8 Mm Thick. Crca Or Equivalent Grade Steel Having 5 Loading Levels Formed By 4 Adjustable Shelves For 1980 Mm Height Body And 6 Loading Levels With 5 Adjustable Shelves For 2361Mm Height Body. -Main Body Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction: Rigid Knock Down Construction Made Of 0.8 Thick Crca Or Equivalent Grade Steel. Each Body Block Consists Of 1 Main Unit & Then Add-On Units. -Front Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose. -Back Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose. -Back Panel Made Of 0.6 Thick Crca Or Equivalent Grade Steel Fixed Together Using Machine Screws To Prevent Access To Inside Files From The Outside. -Door Frame Made Of 0.8 Thick Crca Or Equivalent Grade Steel Of 2 Vertical Door Stiffeners Providing Rigidity To The Entire Body. -Shelf Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction 12-Bend Panel Made Of 0.7 Thick Crca Or Equivalent Grade Steel Having Max Load Bearing Capacity Is 100 Kg Uniformly Distributed Per Shelf, Height Of 351Mm Between Two Shelves. The Last Loading Level For Shelf Is 1721Mm From Ground Level For 1980H Body And 2107Mm From Ground For 2361H Body. Shelves Are Mounted On Support Brackets & Shelf Level Can Be Adjusted At Approx. 25.4 Pitches. There Are 4 Adjustable Shelves Per Body For 1980H And 5 Adjustable Shelves Per Body For 2361H, Giving 5 And 6 Loading Levels For 1980H And 2361H Body Respectively. -Storage Capacity Made Of 0.8Thick Crca Or Equivalent Grade Steel Having Hinged Door Have Recessed Die Cast Handle Cum Lock With 3 Way Locking Through A Lever & Shooting Bolt And Can Hold Up To 10 Nos. Of Box Files -Under Structure Construction Welded Frame Suitably Fabricated To Bear The Loads Based On Configuration Consists Of The Main Channel, Body-Fixing Channel, U-Channel, And Z-Channel Made Of Hr Sheet 3 Mm Thick. -Under Structure Construction Finish Epoxy Polyester Powder Coat Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Movements Of The System Is Drive Type Configuration Achieved By Rotating A Pu Hand Wheel Connected To The Rollers Through A ‘Sprocket-Chain Arrangement Mounted On The Side Of The Body Covered By A 1 Mm Thick Crca Or Equivalent Grade Steel Sheet Drive Unit Cover With Dimensions 1202Mm X 398Mm X 87Mm -Rail Channels- A ‘C Section 3 Mm Thick Hr Sheet On Which Rail Ms Bright Bar Of Sq 25.4Mm Is Firmly Fixed From Bottom Using Counter Sunk Screws. The Rail Channels Are Of 3 Lengths I.E., 800Mm, 1600Mm And 2400Mm. Label Holder Is An Aluminium Extrusion Of Length 453Mm For Ld/Sd And 910Mm For Td, Fitted On To Front Cover Of Body. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Mobile Compactor Storage Unit -02 3 Bay Drive Type Compactors With 3 Bay Sd - 1 No, 3 Bay Td - 2 No, 3 Bay Sl - 1 No. -Size Of Compactor 2361H Mm X 915 W Mm X 457D Mm, 3 Bay Channel 2400 Mm - 1 No, 3 Bay Channel 800 Mm - 1 No. -Main Body : Rigid Knock Down Construction Made Of 0.8 Thick. Crca Or Equivalent Grade Steel Having 5 Loading Levels Formed By 4 Adjustable Shelves For 1980 Mm Height Body And 6 Loading Levels With 5 Adjustable Shelves For 2361Mm Height Body. -Main Body Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction: Rigid Knock Down Construction Made Of 0.8 Thick Crca Or Equivalent Grade Steel. Each Body Block Consists Of 1 Main Unit & Then Add-On Units. -Front Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose -Back Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose. -Back Panel Made Of 0.6 Thick Crca Or Equivalent Grade Steel Fixed Together Using Machine Screws To Prevent Access To Inside Files From The Outside -Door Frame Made Of 0.8 Thick Crca Or Equivalent Grade Steel Of 2 Vertical Door Stiffeners Providing Rigidity To The Entire Body -Shelf Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction 12-Bend Panel Made Of 0.7 Thick Crca Or Equivalent Grade Steel Having Max Load Bearing Capacity Is 100 Kg Uniformly Distributed Per Shelf, Height Of 351Mm Between Two Shelves. The Last Loading Level For Shelf Is 1721Mm From Ground Level For 1980H Body And 2107Mm From Ground For 2361H Body. Shelves Are Mounted On Support Brackets & Shelf Level Can Be Adjusted At Approx. 25.4 Pitches. There Are 4 Adjustable Shelves Per Body For 1980H And 5 Adjustable Shelves Per Body For 2361H, Giving 5 And 6 Loading Levels For 1980H And 2361H Body Respectively. -Storage Capacity Made Of 0.8Thick Crca Or Equivalent Grade Steel Having Hinged Door Have Recessed Die Cast Handle Cum Lock With 3 Way Locking Through A Lever & Shooting Bolt And Can Hold Up To 10 Nos. Of Box Files -Under Structure Construction Welded Frame Suitably Fabricated To Bear The Loads Based On Configuration Consists Of The Main Channel, Body-Fixing Channel, U-Channel, And Z-Channel Made Of Hr Sheet 3 Mm Thick. -Under Structure Construction Finish Epoxy Polyester Powder Coat Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Movements Of The System Is Drive Type Configuration Achieved By Rotating A Pu Hand Wheel Connected To The Rollers Through A ‘Sprocket-Chain Arrangement Mounted On The Side Of The Body Covered By A 1 Mm Thick Crca Or Equivalent Grade Steel Sheet Drive Unit Cover With Dimensions 1202Mm X 398Mm X 87Mm -Rail Channels- A ‘C Section 3 Mm Thick Hr Sheet On Which Rail Ms Bright Bar Of Sq 25.4Mm Is Firmly Fixed From Bottom Using Counter Sunk Screws. The Rail Channels Are Of 3 Lengths I.E., 800Mm, 1600Mm And 2400Mm. Label Holder Is An Aluminium Extrusion Of Length 453Mm For Ld/Sd And 910Mm For Td, Fitted On To Front Cover Of Body. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Magazine Stand Overall Dimensions 900Mm(W)X450Mm(D)X1830Mm(H). -Steel Periodical Display Rack Providing, Placing And Supplying Of Display Rack. -Rigid Knockdown Construction, Panels Shall Be Made From Crca Or Equivalent Grade Steel 0.6 Mm Thick -Front Frame Shall Be Made From Crca Or Equivalent Grade Steel 0.8 Mm Thick. Crca Or Equivalent Grade Steel D Grade. -There Shall Be 5 Level Racks, Suitable For Full Cape Size Magazines, Periodicals, Aesthetically Appealing Metal Tray At An Angle For Easy Viewing. -Receding Facility To Access The Storage Behind. -Uniformly Distributed Load Capacity Per Each Shelf Is 40 Kg. -Shall Be Epoxy Polyester Powder Coated To The Thickness Of 50 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) Vendor Should Submit Detail Shop Drawing With All Dimensions. , Storage Cabinet 1 Body Made From 18Mm Plb With All The Edges Sealed With 0.8 Mm Thick Pvc Edge Band. The Shelves Is Made From 18 Mm White Plt And Edges Are Sealed With 0.8 Mm Edge Band. The Back Panel Is 9Mm White Plt Assembled With Suitable Fittings. The Bottom Shelf Is Fixed And Other Shelves Have One Step Adjustment For Optimizing The Space. -Doors Made From 18 Mm Plb With 2 Mm Edge Band On All Edges Ad A Flush Plastic Handle Is Fitted Vertically At The Centre Of The Door Having Suitable Hinges And Hdu Is Fitted With Height Adjustment And Has A Three-Point Lock. -All The Storages Are Fitted With A 6 Mm Leveller At Bottom For Levelling As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Storage Cabinet -02 Body Made From 18Mm Plb With All The Edges Sealed With 0.8 Mm Thick Pvc Edge Band. The Shelves Is Made From 18 Mm White Plt And Edges Are Sealed With 0.8 Mm Edge Band. The Back Panel Is 9Mm White Plt Assembled With Suitable Fittings. The Bottom Shelf Is Fixed And Other Shelves Have One Step Adjustment For Optimizing The Space. -Doors Made From 18 Mm Plb With 2 Mm Edge Band On All Edges Ad A Flush Plastic Handle Is Fitted Vertically At The Centre Of The Door Having Suitable Hinges And Hdu Is Fitted With Height Adjustment And Has A Three-Point Lock. -All The Storages Are Fitted With A 6 Mm Leveller At Bottom For Levelling As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Library Table 1 1650 X 600 Desk Based Modular Workstation With System Ht-750 Mm. -Partial Screens: Fabric T- Mould, 19Mm Thick Screen Of 450Mm Ht., Mounted On Studs. -Legs: Providing Metal Powder Coated Cube Leg Vertical (40X40Mm)& Rigid Support (50X30Mm). Legs Are For Standard Workstation Height Of 750Mm. All Legs Have Levelling Screws For Adjustment In Case Of Uneven Floor. -Understructure Comprising Of Metal Powder Coated Cross, Made Up Of Metal Powder Coated Finish -Wire Management: Electric Switch Plate Of 8+3 Module For Power And Data Points. -Worksurface - 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lipping Edge Banding Of Size 1650 Mm W X 600 Mm D. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Library Table -2 2400 X 1200 Providing And Placing Modular Workstation Desk Based Modular Workstation With System Ht - 750 Mm. -Legs: Providing Metal Powder Coated Cube Leg. Legs Are For Standard Workstation Height Of 750Mm. All Legs Have Levelling Screws For Adjustment In Case Of Uneven Floor. -Understructure Comprising Of Metal Powder Coated Cross, Made Up Of Metal Powder Coated Finish -Wire Management: Electric Switch Plate Of 8+3 Module For Power And Data Points. -Worksurface - 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lipping Edge Banding Of Size 2400 Mm W X 1200 Mm D. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Reception Table Work Surface Made Of 25Mm Thick Pre-Laminated Twin Board Of High Quality Wood And Approved Shade Confirming To Edge Banded With Matching 2 Mm Thick Pvc Lipping. -Wire Managementu-Access Flap Along With A Grommet Is Provided On Work Surface For Wire Management. Power Box Made With 0.8 Mm Thick Crca Or Equivalent Grade Steel, With Electric Switch Plate Of 8+3 Module Which Is Fixed With Worktop Along The Width Ataccess Flap Position. Wire Riser Made Of 0.8Mm Crca Or Equivalent Grade Steel Is Provided For Proper Wire Management. -Modesty Panel & Side Skirting - Made Of 25Mm Thick Pre-Laminated Twin Board Of High Quality Wood And Approved Shade, Edge Banded With Matching 2 Mm Thick Pvc Lipping. -Under Structure And Top Shelf - Made Of 18 Mm Thick Pre-Laminated Twin Board Of High-Quality Wood And Approved Shade, Edge Banded With Matching 2 Mm Thick Pvc Lipping - Hinge Door + Drawer Unit - Made Of 18Mm Thick Pre-Laminated Twin Board Of High Quality Wood And Approved Shade, Edge Banded With Matching 2 Mm Thick Pvc Lipping. Drawer Bottom Is Made Of 5.5Thick Mdf Whiteboard Handle Is Provided For Ease Of Opening. Hdu And Drawer Are Provided With Cam Lock For Security. -Organizer Plate Made Of 1.2Mm Crca Or Equivalent Grade Steel Is Provided For Magnetic Sticky Notes. -Bag Hanger Hook Made Of 1.2Mm Crca Or Equivalent Grade Steel Is Provided For Bag Hanging 2400 X 1770 X 870 Mm , Side Table Providing, Supplying And Placing Of Side Table. -Side Table Glass Is 10 Mm Thick Black Tinted Toughened Glass Uv Glued With Bushes Made In Ss 202 Grade Or Equivalent For Facing With Under Structure. -Under Structure Is A Welded Assembly Made In Ss202 Or Equivalent Grade -Width Of Table= 60.0 Cm, Depth=60.0 Cm, Height=34.9 Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions , Central Table Providing, Supplying And Placing Of Coffee Table. -Center Table Glass Is 10 Mm Thick Black Tinted Toughened Glass Uv Glued With Bushes Made In Ss 202 Or Equivalent Grade For Facing With Under Structure. -Under Structure Is A Welded Assembly Made In Ss202 Grade Or Equivalent -Width Of Table= 112.0 Cm, Depth=60.0 Cm, Height=34.9 Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions , Round Table Circular 900Mm Providing And Placing Meeting Tables With Worktop Height - 750 Mm. Cube Legs Vertical (40X40Mm).Rigid Support-(50X30Mm) Are Available For Work Top Level 750 Mm From Base. -Worktop Is 25Mm Thick Prelaminated Particle Board With Pvc Lipping As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Table A- 750X1500 Providing And Placing Desk Based Modular Workstation With System Height - 750 Mm. -Legs Providing Metal Powder Coated Cube Leg Vertical (40X40Mm) Rigid Support (50X30Mm). Legs Are For Standard Workstation Height Of 750Mm. All Legs Have Levelling Screws For Adjustment In Case Of Uneven Floor. -Under Structure Made Up Of Metal Powder Coated Finish And The Entire Assembly Are Fixed To The Worktop. -Wire Management Will Be Provided With Electric Switch Plate Of 8+3 Module, Considered For Power And Data Points. . (Vendor To Submit Powder Coating Laboratory Test Certificate) -Metal Modesty And Wooden Modesty Are Mounted On The Worktop Perforated With The Help Of The Modesty Mounting Brackets At 400 Mm From Ground. -Worksurface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lipping Edge Banding Of Size 1500X 750 Mm For Main Table As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Meeting Table Eight-Seater 2350 X 1150 Mm Work Top Made Of 25Mm Thick Pre-Laminated Twin Board Of High-Quality Wood; Edge Banded With Matching 2 Mm Thick Pvc Lipping. Access Panels Provided With Soft Closing Hinges. -Under-Structure Consists Of Mixture Of 25Mm And 18Mm Pre-Laminated Twin Board Of High-Quality Wood; Edge Banded With Matching 2 Mm Thick Pvc Lipping. Access Panels Provided With Soft Closing Hinges. Aluminium Alloy 63400 Or Equivalent - Wp Profile Is Added At Bottom Edges For Improving The Aesthetics. -Wire Management Will Be Provided With Electric Switch Plate Of 8+3 Module, Considered For Power And Data Points. Beside Each Cut-Out, An Additional Cut-Out With Plate Is Provided For Mounting Audio-Visual Cables (E.G. Hdmi, Vga-A, Etc.) Vendor Should Submit Detail Shop Drawing With All Dimensions , Table B Supplying And Placing In Position Main Table, Of Dimension 1800X2100X750 Mm. -Primary Work Surface Made Of 25Mm Thick Mdf One Side Pre-Laminate Board With 0.4Mm Pvc. -Secondary Work Surface Made Of 25Mm Thick Mdf One Side Pre-Laminate Board With 0.4Mm Pvc. -Under Structure Made Of 25Mm Thick Pre-Laminated Twin Board Of High Quality Wood, Edge Banded With Matching 2 Mm Thick Pvc Lipping. Integrated Pedestal Made Of 25Mm Thick Pre-Laminated Twin Board Of High-Quality Wood, Edge Banded With Matching 2 Mm Thick Pvc Lipping.  Drawer Fronts Made Of 25Mm Thick Mdf One Side Pre-Laminate Board With 0.4Mm Pvc Membrane Pressed On To Top. Pedestal Construction Is Box-Box-File Type Which Uses Powder Coated 400 Mm Long Metal Panel Drawer Slides. Drawer Extension Is 325 Mm. Drawers Have A Soft Closing & Anti Slam Mechanism. Handles Are Provided For Ease Of Opening. Pedestals Are Provided With Lock For Security. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Modular, Space-Optimizing Desk With Bench N (Three-Seater Curved) Providing, Supplying And Placing Of Desk Cum Bench N Seater Product Which Provides An Elegant, Modular Solution With 360-Degree Swivel Seat For Easy Entry/Exit And Height-Adjustable -Legs Are Made Of Ms Erw Or Equivalent Tube Section Of Size 75X25X2 Mm Thick Oval Tube With 5 Mm Thick Hr Bracket Sand 2Mm Thick Crca Or Equivalent Grade Steel Brackets On To The Tubes. -Assembly Is Powder Coated With Epoxy Polyester. Leg Height Varies From 705 To 1005 In Pitch Of 50 As Per Layout. Sturdy Anchoring By Anchor Bolts On To Base Of 8Mm Thick Plate For Proper Resting Of Leg. Shoe Made Of Nylon Are Provided At The Bottom For Covering The Base Plate. -Two Side Clads Made Of E18 Mm Thick Plate With 0.8Mm Thick Pvc Lapping And On The Outside Covered With Welded Metal Structure Made Of 2 Mm Thick Crca Or Equivalent Grade Steel Powder Coated With Epoxy Polyester. -Worktop Are Made Of 25 Mm Thick Pre-Laminated Board Of High-Quality Wood; All The Edge Of Work Surface Should Provide With Machine Pressed 2 Mm Thick Pvc Edge Band Glued With Hot Melt Glue. -Seat Has Self-Closing Mechanism. Seat Under Structure Is Made From Combination Of Welded Fabricated Structure Of 5Mm Thick Hr And 8Mm Thick Ply With Moulded Pu Foam Of Density 55 Kg/Cu.Mtr. With Stitched Fabric Made Of Leatherette Or Foam Back Fabric. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Seat Back Is Made From Combination Of 8Mm Thick Ply With Moulded Foam On Top Which In Turn Is Covered With Stitched Upholstery Made Leatherite As Per Or Foam Back Fabric. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Seat Support Frame Is Made From Combination Of Ms Erw Or Equivalent Grade Tube Section Of Size 80X40X2.5 Mm Thick Rectangular Tube And Ms Erw Tube Section Of Size 48X19.1X2 Mm Thick Oval Tube Welded Together. Assembly Is Powder Coated With Epoxy Polyester. -Modesty Is Made Of 25Mm Thick Pre-Laminated Twin Board Of High-Quality Wood, All The Edge Of Modesty Are Provided With Machine Pressed 2 Mm Thick Pvc Edge Band Glue With Hot Melt Glue. Vendor Should Submit Detail Shop Drawing With All Dimensions . , Table C 1650X600X770Mm Providing, Supplying And Placing Of Conference Table With Product Size 1650 X 600 X 770Mm -Worktop Should Be Made Of 25Mm Thick High-Quality Wood, Edges Shall Be Provided With Machine Pressed 2 Mm Thick Pvc Lipping Glued With Hot Melt Eva Glue. -All Tables Are Provided With Heavy Duty Table Connector Made With Metal Integrated Engineering Plastic. -Modesty Should Be Made Of 15Mm High Quality Wood, Edges Shall Be Provided With Machine Pressed 2 Mm Thick Pvc Lipping Glued With Hot Melt Eva Glue. -Recta Table Modesty Is Provided With A Latch Made Of 2Mm Thick Crca Or Equivalent Grade Steel And Is Powder Coated With Min 45-Micron Thickness Of Epoxy Polyester Coating. Latch Is Fixed With Knurled Bush Made Of 20Mm Dia Ms Rod In A Black Finish. Latch Can Be Used To Align Modesty If Two Or More Recta Tables Are Connected Side By Side. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Modesty Is Provided With Rubber Stopper Made Of Tpe Rubber To Reduce Banging While Folding Table. -Legs Should Be Made By Welding The Combination Of Ms Erw Or Equivalent Grade Round Tube Ø63.5 X 2Mm Thick, Flanges Made Crca Or Equivalent Grade Steel Sheet Of 1.6Mm Thick And 1.2Mm Thick Inside Plates Made Of Hr 5Mm Thick Sheet. Assembly Is Epoxy Polyester Powder Coated (Min 45 Micron). -Legs Are Provided With Casters Of Ø65 Mm Lockable Type For Ease Of Movement And Can Be Locked When Required At Any Position. Each Castor Is Also Provided With 2 Knurled Disk Of 50Mm Dia And 5 Mm Thick Made Of Ms Bar With Zn Black Finish For Levelling Adjustment Of 10Mm.. -Table Top Connected With Spring Loaded Mechanism With Pull Handle Made Of Ms Erw Ø16X1.2Mm Thick With An Insert Tube Of Ø12.7X1.6Mm Thick Tube. Coated With Epoxy Polyester Powder Coated (Min 45 Micron) To Operate Table Top. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Table Top With Modesty Folds Upside At Offset Centre Pivot Provided On Support Bracket Which Is Aluminium Alloy Pressure Die Cast Part Coated With Epoxy Polyester Powder Coat (Min 45 Micron). Modesty Is Connected To Worktop With 90 Deg Rotating Hinge Made Of Engineering Plastic. -All Type Of Tables Are Provided With Power Box Which Has Two Universal Power Socket Of 2 Annual Periodical Maintenance Each, One Switch Of16 Annual Periodical Maintenance And 1 Fuse Of 4 Annual Periodical Maintenance With 1000Mm Cable With Male And Female Gst Connector. -All Tables Are Provided With Wire Channel And Wire Clip Made Of 1.2Mm Thick Spring Steel And Is Powder Coated With Min 45 Micron Thickness Of Epoxy Polyester Coating (Vendor To Submit Powder Coating Laboratory Test Certificate) Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation L Type Providing And Placing Desk Based Modular Workstation With System Height - 1200 Mm. -Partial Screens: Fabric T- Mould, 19Mm Thick Screen Of 450Mm Ht., Mounted On Studs. -Legs Providing Metal Powder Coated Cube Leg. Legs Are For Standard Workstation Height Of 750Mm. -Under Structure Made Up Of Metal Powder Coated Finish And The Entire Assembly Is Fixed To The Worktop. -Wire Management Will Be Provided With Electric Switch Plate Of 8+3 Module, Considered For Power And Data Points. -Worksurface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lapping Edge Banding Of Size 1500X1500X600 Mm. -Metal And Wooden Modesty Are Mounted On The Worktop With The Help Of The Modesty Mounting Brackets. -Nova Free Standing Pedestal With Flat Metal Front Of Size 390W X 435D X 646Ht, 1Dr = 1 Box + 1 File, Central Locking. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation 2 -900X600Mm Providing And Placing High-Functionality, Modular Office Workstation System & Tile Based Modular Workstation, With Partition Thickness As 52.4 Mm Thick And Ht - 1200 Including Powder Coated Aluminium Trims. -Fin Are 22.5 Mm Thick Panel Which Are 18 Mm Thick Ply Boards Wrapped With Fabric At Intermediate Level. Top Block Finished In Fabric Finish. Bottom Block Is Finished In Metal Finish. -Wire Management: Wires Shall Be Taken Into The System Through Cable Ducts From The Junction Boxes And It Is Carried Up To The Panels Through Concealed Conduits Inside The Blocks. -Half Screen With Frame At Intermediate Position Between 2 People And At The End Above Worktop In Fabric Finish. -Metal Powder Coated Legs At The End And Shared Condition. System Shall Also Have 120 Mm High Powder Coated Standalone Panel Legs To Give The System An Elevated Look. All Partitions And Side Panels Have Levelling Screws For Adjustment In Case Of Uneven Floor -Work Surface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lapping Edge Banding Of Size 900 Mm W1 X600 Mm D As Per Order. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation 3- 900X600Mm Providing And Placing High-Functionality, Modular Office Workstation System & Tile Based Modular Workstation, With Partition Thickness As 52.4 Mm Thick And Ht - 1050Mm Including Powder Coated Aluminium Trims. -Fin Are 22.5 Mm Thick Panel Which Are 18 Mm Thick Ply Boards Wrapped With Fabric At Intermediate Level. Bottom Block Is Finished In Metal Finish. -Wire Management: Wires Shall Be Taken Into The System Through Cable Ducts From The Junction Boxes And It Is Carried Up To The Panels Through Concealed Conduits Inside The Blocks. -Half Screen With Frame At Intermediate Position Between 2 People And At The End Above Worktop In Fabric Finish. -Metal Powder Coated Legs At The End And Shared Condition. System Shall Also Have 120 Mm High Powder Coated Standalone Panel Legs To Give The System An Elevated Look. All Partitions And Side Panels Have Levelling Screws For Adjustment In Case Of Uneven Floor -Work Surface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lapping Edge Banding Of Size 900 Mm W1 X600 Mm D As Per Order. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Main Table 1650 X 750, Eru- 1200W X 450D With Pedestal Modular Desk-Based System Of Height 750 Mm. -Cube Legs Are Fabricated By Argo Shield & Have A Square Section. Cube Legs(40X40Mm) And Rigid Support (50X30Mm) Are Available For Work Top Level 750 Mm From Base. -Wire Management: Single Power Box With Raiser For Manager Modules, Single Tables (8+3 Anchor Roma). Soft Closing Access Flap With Brush. -Metal Modesty Is Made From 0.8 Mm Thick Crca Or Equivalent Grade Steel. Metal Modesty Is Mounted On The Worktop With The Help Of The Modesty Mounting Brackets. -Worktop Of 25Mm Thick Prelaminated Particle Board With Pvc Lapping. -Nova Free Standing Pedestal With Flat Metal Front Of Size 390X435X646 Mm, 1Dr = 1 Box + 1 File, Central Locking. Vendor Should Submit Detail Shop Drawing With All Dimensions , Modular, Space-Optimizing Desk Legs Are Made Of Ms Erw Or Equivalent Grade Tube Section Of Size 75X25X2 Mm Thick Oval Tube With 5 Mm Thick Hr Brackets And 2Mm Thick Crca Or Equivalent Grade Steel Brackets Welded On To The Tubes. Assembly Is Powder Coated With Epoxy Polyester. Leg Height Varies From 705 To 1005 In Pitch Of 50 As Per Layout. Sturdy Anchoring By Anchor Bolts On To Base Of 8Mm Thick Plate For Proper Resting Of Leg. -Shoe Made Of Nylon Are Provided At The Bottom For Covering The Base Plate. -Two Side Clads Made Of 18 Mm Thick Plate With 0.8Mm Thick Pvc Lapping And On The Outside Covered With Welded Metal Structure Made Of 2 Mm Thick Crca Or Equivalent Grade Steel Powder Coated With Epoxy Polyester. -Worktop Are Made Of 25 Mm Thick Pre-Laminated Board Of El-P2 Grade And Approved Shade. All The Edge Of Work Surface Are Provided With Machine Pressed 2Mm Thick Pvc Edge Band Glued With Hot Melt Glue. -Modesty Is Made Of 25Mm Thick Pre-Laminated Twin Board Of E1-P2 Grade And Approved Shade. All The Edge Of Modesty Are Provided With Machine Pressed 2 Mm Thick Pvc Edge Band Glue With Hot Melt Glue As Per Order. -Vendor Should Submit Detail Shop Drawing With All Dimensions.
Contract Date: Jun 06, 2026 Contract Value : 6.64 Crore
Government Departments No of Bidders 8
Maharashtra View Result →
24.
Public Administrative Department #11180857 Price Bid
Tender for P&F Supply, Installation, Testing and Commissioning Work Of Led Lights With Phase Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Led Street Light Fixture With Minimum Lumen Output 3700 Lm , Led Street Light Fixture With Minimum Lumen Output 5600 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 40 Mm Dia. , Supplying And Drawing Of Xlpe Insulated Lt Aerial Bunched Aluminium Conductor Cable Confirming To Is 14255/1995 And Is 398 (Pt-4)/ 1994 And As Per Discom Specs. On Existing Cross Arms Through I Hook With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 1 X 25 Sq. Mm. + 1X25 Sq. Mm. (Insulated) , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity 99.7 %, Round / Flat Strip Armouring, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr. 2.5 Sq. Mm 2 Core , Supply And Fixing Of 11 Kv Pin Insulator Confirming To Is:731:1971 With Latest Ammendment On Existing Bracket Including All Accessories Like Ms Forged Hot Dipped Gi Pin Confirming To Is 2486(Part-I)/1993 & Is:2486 (Part-Ii)/1989 With Latest Amendment, And As Per Latest Discom Specs. Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Plate Earthing As Per Is:3043 With Copper Earth Plate Of Purity 95% Of Size 600Mm X 600Mm X 3.0Mm By Embodying 3 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Main Cubical Panel / Street Light Control Panel providing and Fixing Testing & Commissioning Of Kiosk Type Weather Proof Out Door Main Cubical Panel Size 750 Mm X 1250 Mm X 500 Mm (App.) Made Out Of 14 Gauge Ms Sheet Front And Back Both Side Openable Duly Hinged Door With Locking Arrangement By Providing Both Side Held Draft And All Required Hard Wares. The Cubical Should Be Dust And Vermin Proof Followed By Coat Of Zimpholite Primer And Finally Two Coats Of Enamal Gray Paint. The Cubical Should Be Mounted With Hard Ware On Angle Iron Frame Size 50 X 50 X 6 Mm And 1500 Legs Duly Painted Framed Be Grouted 750 Mm Below Ground Level With Cement Concrete 1:3:6 In 1000 X 500 X 600 Mm And Providing Brick Masonary Along Angle Iron Frame Above G.L. (As Per Ruidp 2017)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
25.
Public Administrative Department #11180855 Price Bid
Tender for P&F Supply, Installation, Testing and Commissioning Work Of Led Lights With Phase Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Led Street Light Fixture With Minimum Lumen Output 3700 Lm , Led Street Light Fixture With Minimum Lumen Output 5600 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 40 Mm Dia. , Supplying And Drawing Of Xlpe Insulated Lt Aerial Bunched Aluminium Conductor Cable Confirming To Is 14255/1995 And Is 398 (Pt-4)/ 1994 And As Per Discom Specs. On Existing Cross Arms Through I Hook With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 1 X 25 Sq. Mm. + 1X25 Sq. Mm. (Insulated) , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity 99.7 %, Round / Flat Strip Armouring, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr. 2.5 Sq. Mm 2 Core , Supply And Fixing Of 11 Kv Pin Insulator Confirming To Is:731:1971 With Latest Ammendment On Existing Bracket Including All Accessories Like Ms Forged Hot Dipped Gi Pin Confirming To Is 2486(Part-I)/1993 & Is:2486 (Part-Ii)/1989 With Latest Amendment, And As Per Latest Discom Specs. Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Plate Earthing As Per Is:3043 With Copper Earth Plate Of Purity 95% Of Size 600Mm X 600Mm X 3.0Mm By Embodying 3 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Main Cubical Panel / Street Light Control Panel providing and Fixing Testing & Commissioning Of Kiosk Type Weather Proof Out Door Main Cubical Panel Size 750 Mm X 1250 Mm X 500 Mm (App.) Made Out Of 14 Gauge Ms Sheet Front And Back Both Side Openable Duly Hinged Door With Locking Arrangement By Providing Both Side Held Draft And All Required Hard Wares. The Cubical Should Be Dust And Vermin Proof Followed By Coat Of Zimpholite Primer And Finally Two Coats Of Enamal Gray Paint. The Cubical Should Be Mounted With Hard Ware On Angle Iron Frame Size 50 X 50 X 6 Mm And 1500 Legs Duly Painted Framed Be Grouted 750 Mm Below Ground Level With Cement Concrete 1:3:6 In 1000 X 500 X 600 Mm And Providing Brick Masonary Along Angle Iron Frame Above G.L. (As Per Ruidp 2017)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
26.
Defence #11177699 AOC
Tender For Repair/ Replacement Of Light Fitting With Connected Items Of Tarmac, Sun Shelters And Bps Under Ge (Af) Jamnagar No 1; 1 Taking down carefully aluminum/copper flame proof point wiring complete of any type (surface ERW conduit for light point, fan point, or power point complete with all fitting such as rotary switches, sockets, fan regulators etc complete and making good disturbed surfaces complete all as specified as directed by Engineer in Charge. 2 Taking down carefully flame proof/flood light/high bay light fittings of any description from existing position from Hanger/tarmac/BPs complete all as specified as directed by Engineer in Charge. 3 Taking down old sub main wiring including rigid steel conduit with all accessories and removing to and making good disturbed surfaces complete all as specified as directed by Engineer in Charge. 4 Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified as directed by Engineer in Charge. 5 All as per item No 04 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke & Halogen, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified as directed by Engineer in Charge. 6 Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete.Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment complete all as specified as directed by Engineer in Charge. 7 Material & Labour in repairfor sub main wiring with 2 run single core multistranded copper conductor cable of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class B (ISI Makes) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. 8 Material & Labour in repairfor sub main wiring with 2 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class B (ISI Makes) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. 9 Material & Labour in repairfor sub main wiring with 4 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class B (ISI Makes) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge. Note: 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. 10 Supply and fix in repairs flame proofand weather proof industrial type DBs with and including various combination of incoming and outgoing flame proof MCBs suitable for and including (a) 01 No MCB TPN 63 Amps, C type (incoming) (b)06 Nos MCB SP 10 Amps C type (c) 2 Nos MCB SP 20 Amps C type, including necessary connection, complete all as specified as directed by Engineer in Charge. 11 S&F in replacement ofLED flood Light fitting 200 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified as directed by Engineer in Charge.Make:-cat no. JETAVALOURFL200WLED757MODNBLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES. 12 S&F in replacement ofLED flood Light fitting 240 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified as directed by Engineer in Charge.Make:-cat no.JETAVALOURFL240WLED757MODWBLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES.. 13 S&F in replacement ofLED flood Light fitting 120 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified as directed by Engineer in Charge.Make:- cat no. JETAIRISFLS120WLED757SYMLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES. 14 S&F in replacement Flame proof weather proof LED Flood light of capacity 100 wattepoxy finish withLM 6 aluminiumhousing , heat resistant borosilicate tubular glass held in two alluminium cups with inbuilt DRIVER accessoriescomplete all as specified as directed by Engineer in Charge.Make: Sudhiror equivalent in CROMPTON/Bajaj 15 Supply and fix in repair weather proof and flame proof PVC knob suitable for flame proof DBs/switch of any size and capacity as per site requirement complete all as specified as directed by Engineer in Charge. 16 Supply and fixing in repair PVC copper condutor 2.5 sqmm 4 core complete all as specified as directed by Engineer in Charge. 17 M&L for taking outMotor & pump of 7.5 KW/ 10 HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening themotor, cutting & removing old and burnt windingwire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate,reassembling, refixing in same position & connecting including testing and commissioning complete all as specified as directed by Engineer in Charge. 18 Supply and fixing pully to motor chain (MS) suitable for 10 HP Motor complete all as specified as directed by Engineer in Charge. 19 Supply and fixing limit switch suitable for motorised shutter having 10 HP motor complete all as specified and as directed by Engr-in-charge. Note Cost of welding, proper allingment of limit switch are deemed to be inlcuded in the qutoed rate complete all as specified as directed by Engineer in Charge. 20 Supply and fixing SWR 6mm dia complete all as specified as directed by Engineer in Charge. 21 Supply and fixing cable carrier with clamp complete all as specified as directed by Engineer in Charge. 22 Supply and fixing PVC Sheathed copper cable 0.5 sqmm 7 core complete all as specified as directed by Engineer in Charge. 23 Supply and fxing control panel suitable for Motorised shutter having 10 HP Motor complete with following accessoriescomplete all as specified as directed by Engineer in Charge.(a) 3/4 pole power contactor 45 A, 415 V, coil voltage 230 V with including 1 NO & 1 NC contact connecting complete 02 Nos (b) Selector switch of suitable capacity, Push Button to operator shutter(c) MCB TPN 02 Nos 63 Amp (d)MCCB 63 Amp as Incomer , relay, RYB indicator, Push Buttons or any other parts required for operation of Motoriszed shuttercomplete 24 S&F in replacement of Sheet moulding compound (SMC) junction box of size 350 mm x 200 mm x 150mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps C type, fixed on pole with mild steel clamps, nuts and bolts complete all as specified as directed by Engineer in Charge.Make:-Sintex/Legrand/Siemens/EPP composite Pvt Ltd. 25 Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 10 sqmm 2 /4 coreincluding cable cover complete all as specified as directed by Engineer in Charge. 26 Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 16 sqmm 4coreincluding cable cover complete all as specified as directed by Engineer in Charge. 27 Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 25 sqmm 3.5coreincluding cable cover complete all as specified as directed by Engineer in Charge. 28 Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge. 29 Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge. 30 Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge. 31 Note for ser No 28 to 30. XLPE cable to be fixed on wall/trusses/roof with the help of steel clamp/Tie of suitable size. Cost of the same are deemed to be inlcuided in the quoted rate complete all as specified as directed by Engineer in Charge. 32 S&F in repair PVC insulated, 2 core 2.5 Sqmm round sheathedcopper conductor(flexible) industrial cablefire retardant complete all as specified as directed by Engineer in Charge. 33 S&F in repair PVC insulated, 2 core 10 Sqmm round sheathedcopper conductor(flexible) industrial cablefire retardant complete all as specified as directed by Engineer in Charge. 34 S&F in replacement Tubes 40 mm bore, light grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified as directed by Engineer in Charge. 35 S&F in replacement Tubes 50 mm bore, light grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified as directed by Engineer in Charge. 36 Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC Casing capping of suitable size, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC terminal box of suitable sizecomplete all as specified as directed by Engineer in Charge. 37 All as per item No 36 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch complete all as specified as directed by Engineer in Charge. 38 All as per item No 36 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch complete all as specified as directed by Engineer in Charge. 39 All as per item No 4 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified as directed by Engineer in Charge. 40 S&F inSwitch piano, flush type single pole, one way 5 Amp including connection complete all as specified as directed by Engineer in Charge. 41 Supply & Fixing Socket outlet 3 pin, 6A, flush type including connection complete all as specified as directed by Engineer in Charge. 42 S&Fswitch flush type 16 Amps,including connection complete all as specified as directed by Engineer in Charge. 43 S&F socketflush type 6/16 Amps, 2 in 1 multipurpose including connection complete all as specified as directed by Engineer in Charge. 44 M & L in repair for Ceiling rose 3 pin flush type 6 Amps, 240 volts AC ISI marked complete all as specified as directed by Engineer in Charge. 45 Supply and fixingMCCB triple pole and neutral , DPX3 thermal magnetic capacity of 100 Amps,415 V and 16KA Short Circuit Breaking Capacity complete all as specified as directed by Engineer in Charge. 46 Supply and fix MCB’ssingle pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 47 Supply and fix MCB’ssingle pole & neutral, 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 48 Supply and fix MCB’ssingle pole & neutral, 40 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 49 Supply and fix MCB’striple pole and neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 50 Supply and fix MCB’striple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 51 Supply and fix in repair of Single pole and neutral enclosure with a two pin and earthplug and socket complete with one double pole MCB 20ampc curve complete all as specified as directed by Engineer in Charge. 52 Supply and fix in repair of Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp C Curve complete all as specified as directed by Engineer in Charge.
Contract Date: Jan 30, 2026 Contract Value : 28.95 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 11
27.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
28.
Defence #11162655 Technical Bid
Tender for Material & Labour For In Replacement Of Light/Fan Point Wiring With 1.5 Sq Mm (Nominal Area), Pvc Insulated Unsheathed (Frlsh), 1100 Volts Grade, Multi-Stranded Copper Conductor, In And Including Pvc Casing Capping Of Adequate Size With All Fittings And Accessories Including Pvc Boxes For Housing The Switches ( Make Of Box Prestoplast,Prestoteak), Including Pvc Insulated And Unsheathed (Frlsh)Single Core Multi-Stranded Copper Conductor Cable Of Size 1.5 Sq Mm Green In Colour As Earth Continuity Conductor Connected To Common Earth Dolly Upto Ceiling Rose/Light Point Complete All As Specified And Directed. , All As Per Item No 1 Here In One Bell/Buzzer Point Controlled By One Bell Push Complete All As Specified And As Directed . , All As Per Item No. 1 Here In Before One 3 Pin Socket Outlet, 6 Amps On The Same Board With Other Switches, With Cables 1.5Sq. Mm Size Complete All As Specified And Directed. , All As Per Item No. 1 Here In Before But For One 3 Pin Socket Outlet 6 Amps Three Pin Controlled By One Switch On Independent Board Complete All As Specified Directed. , All As Per Item No. 1 Here In Before But For One 5 Pin Socket Outlet 16 annual periodical maintenance And 6 annual periodical maintenance Multipurpose Independent Using 2.5 Sqmm Copper Conductor Cable (Multi-Strand) Pvc Insulated And Unsheathed Cable And 2.5 Sqmm Copper (Multistrand) Pvc Insulated And Unsheathed Earth Wire With Pvc Boxes Complete All As Specified. , M&L For Point Wiring For One Socket Outlet 16 annual periodical maintenance On Independent Board With 4 Sq Mm (Nominal Area), Pvc Insulated Unsheathed (Frlsh), 1100 Volts Grade, Multi-Stranded Copper Conductor, In And Including Pvc Casing Capping Of Adequate Size With All Fittings And Accessories Including Pvc Boxes For Housing The Switches ( Make Of Box Prestoplast,Prestoteak), Including Pvc Insulated And Unsheathed (Frlsh)Single Core Multi-Stranded Copper Conductor Cable Of Size 4 Sq Mm Green In Colour As Earth Continuity Conductor Connected To Common Earth Dolly Complete All As Specified And Directed. , S&F Socket Outlet 2 In 1, 5 Pin, 5 annual periodical maintenance Flush Type , S&F Socket Outlet 2 In 1, 5 Pin, 5 And 15 annual periodical maintenance Flush Type , Supply & Fixing Switch Piano Flush Type (Isi Marked), Single Pole, One Way 15 Amp, 240 Volts Complete All As Specified & Directed. , Supply And Fixing In Replacement Of Ceiling Rose, Surface Bakelite, 65Mm X 50Mm , Two To Three Terminals Complete All As Specified & Directed. , Supply & Fixing Switch Piano Flush Type (Isi Marked), Single Pole, One Way 5 Amp, 240 Volts Complete All As Specified & Directed. , S&F Bell/Buzzer Push 5/6 Amp,Flush Type Complete All As Specified & As Directed. , S&F Call Bell Ding Dong Electric Ac, 240 Volt, 50 Hz, Surface Type Complete All As Specified & As Directed. , Supply And Fixing Lamp Holder, Insulated Body With Pack Plate Suitable Batten Fitting On Wall Duly Grouted/Fixed In Solid Block Wall Or On Wooden Board Complete All As Specified And Directed. , Supply & Fixing Modular Switch 1 Way 6A,1 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Switch 1 Way 16A,1 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Socket, 6A - 5 Pin Combined 2 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Socket 6A/16A - 5 Pin Combined 2 Module, 240 Volts Complete All As Specified & Directed. , S&F Modular White Cover Plate With Frame 03 Module , S&F Modular White Cover Plate With Frame 04 Module , S&F Modular White Cover Plate With Frame 06 Module , S&F Modular Surface Mounted Plastic Flush Box 3 Module , S&F Modular Surface Mounted Plastic Flush Box 4 Module , S&F Modular Surface Mounted Plastic Flush Box 6 Module , Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed. , Supply And Fixing Led Light Fitting With High Out Put Diffuser 4 Feet, 20 Watt 220 V Ac Decorative Type With Driver Holder Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Led Tube Rod With High Out Put Diffuser 4 Feet,20 Watt 220 V Ac Decorative One Side Connection Type With Driver Holder Complete All Asspecified & Directed. , Supply And Fixing Led Batten, 220V, Ac Decorative Box Type With Holder Suitable For Fixing Led Tube Light 20/22 Watt Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Warm White) 220 V Ac With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Sitecomplete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Cool Day Light) 220 V Ac With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Sitecomplete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Downlighter Round 18 W (White/Warm White) Type & Driver Incl Integrated Electronic Driver Including Taking Down Old Unsv One Complete All As Specified And Directed , S&F In Replacement Downlighter Surface Mounted Square 1X1 Type 18 W (White/Warm White) Type & Driver Incl Integrated Electronic Driver Including Taking Down Old Unsv One Complete All As Specified And Directed , S&F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light Made Up Of Innovative Die Cast Aluminium Housing High Power Led As Lighting Source With Ip - 66 Power Consumption 35 Watt Complete Input Voltage Of 150-240 Volt (Nominal Rated Voltage 240 Volt) Complete Including Twisted 3 Core Copper Cable Of Size 1.5 Sqmm Dia For Connecting Phase, Neutral And Earth From Ceiling Rose To Light Length As Required At Site,Gi Bracket 25 Mm Dia Pipe And 02 Numbersclmaps, All Fixing Arrangements Such As Fastners, Bilts, Nuts Washers Etc All As Specified And Directed. , S&F In Replacement Led Bulkhead Fitting 10 Watt (Endura Ruby) With All Accessories And Including Connenting Up With Twin Core Twisted With Flexible Copper Conductor Cable With Suitable Size Of 230 Volts , 50 Hz Complete All As Spicified And Directed. , S&F Led Rechargeable Lamp 12 Watt, Cdl, B-22 Cap, (Pin Type), 230W, providing fixing Not Less Tha 0.85 (Min) Complete All As Specified And Directed. , S&F Wire For Circuit/Sub Main Wiring With 1100 Volts Grade Double Core Pvc Insulated And Unsheathed Cable With Multistranded Copper Conductor 4 Sqmm, On Surface Or Recessed Or Drawn In Pvc Casing Capping/Pvc Pipe Along With 4 Sqmm Single Core Copper Conductor Multi Stranded Cable As Earth Continuity Conductor Complete All As Specified And As Directed.(Note: One Rm Pvc Casing Capping/Pvc Conduit ,One Run Of 4 Sqmm Earth Wire And 2 Run Of 4 Sqmm Cable Shall Be Measured As One Run.) , S&F Wire For Circuit/Sub Main Wiring With 1100 Volts Grade Double Core Pvc Insulated And Unsheathed Cable With Multistranded Copper Conductor 6 Sqmm, On Surface Or Recessed Or Drawn In Pvc Casing Capping/Pvc Pipe Along With 6 Sqmm Single Core Copper Conductor Multi Stranded Cable As Earth Continuity Conductor Complete All As Specified And As Directed.(Note: One Rm Pvc Casing Capping/Pvc Conduit ,One Run Of 6 Sqmm Earth Wire And 2 Run Of 6 Sqmm Cable Shall Be Measured As One Run.) , Material & Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600X600x6 Mm Thick Buried Directly In Ground (Earth Pit Not Less Than 2.25M Deep Below The Ground Level) With Top Edge Of The Plate Not Less Than 1.5Mtr Below The Normal Ground Level Connected To Galvanised Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron.Earth Wire Protected By Gi Pipe 15 Mm Bore(Medium Grade) And Connected To Main Switch Board Or Main Control Board As Directed And As Specified And Shown In Electrical Plate No. 3 Of Ssr Part I (2009) Including Necessary Concrete Pit In Plain Cement Concrete (1:3:6) Type C1, Pre-Cast Reinforced Cement Concrete (1:2:4) Type B1 Cover Slab 40 Cm X 40Cm X 5Cm Reinforced With 8Mm Dia Tmt Bars @ 15Cm C/C With One Handle For Lifting Made Out Of 8Mm Dia Bar, Funnel, Wire Mesh, 20Mm Dia Gi Pipe Medium Grade For Watering, Charcoal Or Coke And Salt In Alternate Layers Including Necessary Excavation And Earth Work In Any Type Of Soil And Testing Complete All As Directed By Engineer-In-Charge. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 8 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed To Wall On Pvc Board Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 4 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed To Wall On Pvc Board Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 4 Way 200 annual periodical maintenance Rated Busbar Triple Pole And Neutral Fixed To Wall On Pvc Board Complete All As Specified And Directed. , S&F Mcb Tpn Having Braking Capacity 10Ka, 63 Amps, 240 V Complete All As Specified And Directed. , S&F Mcb Spn Having Braking Capacity 10Ka, 32 Amps, 240 V Complete All As Specified And Directed. , S&F Mcb Sp Having Braking Capacity 10Ka, 6 To 32 Amps, 240 V Complete All As Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 63/100 Amps With Ultimate Breaking Capacity 16 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 125 Amps With Ultimate Breaking Capacity 16 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S&F In Replacement Of Distribution Board Vertical Type Tpn 415 Volt For Fixing 4 Pole Mccb, Double Door Ip 43 Protection, 4 Way With Copper Bus Bars, Neutral Links , Earth Link, Earthing Studs, Blanking Plates, Interconnection Between Incomer Mccb And Bus Bar Duly Prewired Fixed Flush To Wall / Other Surface Complete All As Specified And As Directed. , S&F Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb Of Capacity 20A Complete All As Specified And Directed , Taking Down Of Defective Geyser Of Any Capacity From Different Locations For Repair Including Removing Of Electric Connection, Pipe Fitting Without Any Damage And Refixing The Same After Repair In Same/Desired Location Complete All As Specified & Directed. Note :- The Parts Required For Repair Shall Be Measured Separately Under Relevent Item , S&F Copper/Ss Body Inner Shell Suitable For Water Storage Heater (Geyser) Of 50 Ltr Capacity As Per Sample Including Taking Down Old Unsv Steel/Copper Tank Complete All As Specified And As Directed , S&F Outer Body Of Water Storage Heater (Geyser)Of 50 Ltr Capacity As Per Sample Including Taking Down Old Unsv Outer Body Complete All As Specified And As Directed , S&F Copper/Ss Body Inner Shell Suitable For Water Storage Heater (Geyser) Of 25 Ltr Capacity As Per Sample Including Taking Down Old Unsv Steel/Copper Tank Complete All As Specified And As Directed , S&F Outer Body Of Water Storage Heater (Geyser)Of 25 Ltr Capacity As Per Sample Including Taking Down Old Unsv Outer Body Complete All As Specified And As Directed , M&L For Glass Wool Packing Required For Cover The 25/50 Ltrs Copper Inner Shell To Avoid The Heat Conduction Including Taking Out Old Packing All As Specified & Directed. , S&F Heating Coil 1500 Watt In Existing Storage Water Heater(Geyser) Suitable For 25 Ltrs Capacity All As Specified & Directed. , S&F Heating Coil 2000 Watt In Existing Storage Water Heater(Geyser) Suitable For 25/50 Ltrs Capacity All As Specified & Directed. , S&F Thermostat Range Of 30-80 Degree, As Per Site Requirement, Size As Per Sample All As Specified & Directed. , S&F Non Return Valve Brass Suitable Of 15 Mm Dia Including Taking Down All As Specified & Directed. , S&F Indicator Lamp Red/Green Colour Suitable For Storage Water Heater Any Capacity All As Specified & Directed. , S&F Steel Pipe Connection 45 Cm Long Both End Brass Suitable For Hot Water Supply And Screw Down 15 Mm Gi Pipe Complete All As Specified & Directed. , S&F Steel Pipe Connection 60 Cm Long Both End Brass Suitable For Hot Water Supply And Screw Down 15 Mm Gi Pipe Complete All As Specified & Directed. , M&L For Replacement Of 12 X 100 Mm Bolts Grouting In Bricks Masonary Wall With 1:4 Cm For Mounting Geyser All As Specified & Directed. , S&F Geyser Base Plate Front & Rear Suitable For Existing Geyser Of Capacity 25/50 Ltrs Complete All As Specified & Directed. , S & F Incl Leakage Testing Galvanised Steel Water Tubing Medium Grade 15 Mm Dia Bore With All Fittings Such As Bends, Elbow, Socket, Reducer Etc, Laid Under Floor / Trenches All As Specified & Directed. , S&F 15Mm Bib Tap Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed All As Specified & As Directed By Engr-In-Charge. , Taking Down Of Defective Exhaust Fan Any Capacity/Make/Model/Size From Its Original Locations For Repair Including Sealing Of Cable End , Dismantling Blades, Clamps With Bush, Louvers & Motors, Refixing The Same After Repair & Assembling Complete Set In Same Location Etc Including Testing Complete All As Specified & Directed , S&F In Repair/Replacement Of Exhaust Fan Motor Suitable For Exhaust Fan 200 Mm Sweep Plastic Body. , S&F In Repair/Replacement Of Fan Blade Suitable For Exhaust Fan 200 Mm Sweep Plastic Body. , S&F In Repair/ Replacement Of Old Unservisable Of Frame Made With Engineering Plastic Complete Suitable For 200 Mm Exhaust Fan Plastic Body White Colour All As Directed , Supply Only Louvers Suitable For Exhaust Fans 225/230 Mm Sweep. , Supply Only Louvers Suitable For Exhaust Fans 300Mm Sweep. , Supply Only Louvers Suitable For Exhaust Fans 450Mm Sweep. , S&F In Repair/Replacement Of Exhaust Fan Motor Metal Body Suitable For Exhaust Fans 300 Mm Sweep. , S&F In Replacement Of Old Unservisable Of Frame With Three/Four Legs Suitable For 300 Mm Exhaust Fan Metal Body Of Smoke Grey Colour All As Directed , S&F In Replacement Of Old Unservisable Of Fan Blade With Split Pin Suitable For 300 Mm Exhaust Fan Of Smoke Grey Colour All As Directed , S&F In Repair/Replacement Of Exhaust Fan Motor Metal Body Suitable For Exhaust Fans 450 Mm Sweep. , S&F In Replacement Of Old Unservisable Of Frame With Three/Four Legs Suitable For 450 Mm Exhaust Fan Metal Body Of Smoke Grey Colour All As Directed , S&F In Replacement Of Old Unservisable Of Fan Blade With Split Pin Suitable For 450 Mm Exhaust Fan Of Smoke Grey Colour All As Directed , S&F In Repair/Replacement Of Exhaust Fan Motor Metal Body Suitable For Exhaust Fans 225/230 Mm Sweep , S&F In Replacement Of Old Unservisable Of Frame With Three Legs Suitable For 225/230 Mm Exhaust Fan Metal Body Of Smoke Grey Colour All As Directed , S&F In Replacement Of Old Unservisable Of Fan Blade With Split Pin Suitable For 225/230 Mm Exhaust Fan Metal Body Of Smoke Grey Colour All As Directed , Supplying, Laying, Jointing & Testing Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) With Stranded Aluminum Conductor, 1100 Volts Grade, Of Size 16 Sqmm 4 Core As Per Is 7098 Pt-Ii Laid In Trenches / Ducts / Encased In Gi Pipe / Fixed To Pole Complete All As Directed And Specified. , Description All As Per Item No 82 Above But Of Size 16 Sqmm 2 Core , Taking Down Point Wiring Carefully Copper/ Aluminum (Light,Fan, Socket Or Power) Complete (Fittings Such As Switches Ceiling Rose, Pendents, Regulators, Sockets Etc) , Taking Down Main Switches, Dbs Alongwith Existing Board And Removing The Same From The Site And Making Good The Disturb Surfaces / Portion Of The Wall Etc All Specified And Directed By Eic. , Excavation In Trenches In Any Type Of Soil Not Exc 1.5 Mtrs Wide And Not Exc 1.5 Mtr In Depth For Laying Of Pipe/ Cables/ Poles Etc And Getting Out Any Type Of Soil Complete All As Specified And As Directed. , Returning Fitting In Any Type Of Soil Including Spreading Leveling Watering And Well Ramming In Layers N.Exc 25 Cm Complete All As Specified And As Directed. , Removing Excavated Soils To A Distance N.Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc 1.5 M Above The Starting Point Complete All As Specified And As Directed. , M & L For Laying Of Fine, Clean Sand (River Sand) Free From Sharp Materials And Stone Particals In Trenches For Cushioning Of Cable 8 Cm Thick Under Cable And 15 Cm Thick Over The Cable Including Gently Punning Complete All As Specified And Directed. Note:- The Total Thickness Of Sand Shall Be Measured 18 Cm After Punning. , Supply And Laying Un-Reinforced Precast.Concrete Cable Protection Cover Of Class Lv, Type-1, Flat Size 250Mm X 150Mm X 40 Mm, Local Made Super Quality Complete All As Specified And Directed. , Supply And Laying Galvanised Tube Light Grade Isi Marked Of Size 40 Mm Dia Incl All Fittings In Trenches/Fixed On Pole/Wall/Floor Or Laid In Position Including Repairing Of Demolished Cemented Portion Complete All As Specified And Directed. , S&F Led Driver Suitable For 18W Led Light Complete All As Specified And Directed. , S&F Led Driver Suitable For 36W Led Light Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
29.
Defence #11162654 Technical Bid
Tender for Material & Labour For Light/Fan Point Wiring With 1.5 Sq Mm (Nominal Area), Pvc Insulated Unsheathed (Frlsh), 1100 Volts Grade, Multi-Stranded Copper Conductor, In And Including Pvc Casing Capping Of Adequate Size With All Fittings And Accessories Including Pvc Boxes For Housing The Switches ( Make Of Box Prestoplast,Prestoteak), Including Pvc Insulated And Sheathed (Frlsh)Single Core Multi-Stranded Copper Conductor Cable Of Size 1.5 Sq Mm Green In Colour As Earth Continuity Conductor Connected To Common Earth Dolly Complete All As Specified And Directed. , All As Per Item No. 1 Here In Before But For One 3 Pin Socket Outlet 5/6 Amps Three Pin Controlled By One Switch On Independent Board Complete All As Specified And Directed. , All As Per Item No. 1 Here In Before One 3 Pin Socket Outlet, 5/6 Amps On The Same Board With Other Switches, With Cables 1.5Sq. Mm Size Complete All As Specified And Directed. , All As Per Item No. 1 Here In Before But For One 5 Pin Socket Outlet 15/16 annual periodical maintenance And 5/6 annual periodical maintenance Multipurpose Independent Using 2.5 Sqmm Copper Conductor Cable (Multi-Strand) Pvc Insulated And Unsheathed Cable And 2.5 Sqmm Copper (Multistrand) Pvc Insulated And Unsheathed Earth Wire With Pvc Boxes Complete All As Specified. , All As Per Item No. 1 Here In Before One Light Point Controlled By Two Two-Way Switch 5/6 annual periodical maintenance Complete All As Specified And As Directed . , All As Per Item No. 1 Here In Before One Bell/Buzzer Point Controlled By One Bell Push Complete All As Specified And As Directed . , Supply & Fixing Switch Piano Flush Type (Isi Marked), Single Pole, One Way 5/6 Amp, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Switch Piano Flush Type (Isi Marked), Single Pole, One Way 15/16 Amp, 240 Volts Complete All As Specified & Directed. , S&F Socket Outlet 2 In 1, 5 Pin, 5/6 annual periodical maintenance Flush Type , S&F Socket Outlet 2 In 1, 5 Pin, 5/6 And 15/16 annual periodical maintenance Flush Type , S&F Switch Socket Combination 2 In 1, 5 Pin, 5/6 And 15/16 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , S&F Switch Socket Combination 2 In 1, 5 Pin, 5/6 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , S&F Switch Socket Combination With Box 2 In 1, 5 Pin, 5/6 And 15/16 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , S&F Switch Socket Combination With Box 2 In 1, 5 Pin, 5/6 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , Supply Only Pvc Self Adhesive Insulation Tape Multi Colour Of 12.5 Mm Thick For Electric Wire Complete All As Specified And Directed. , S&F Led Driver Single Phase Input Voltage 220 Volt-240 Volt Ac 50 Hz, providing fixing Not Less Than 0.95, Suitable For 36/20/15 Watt Led Light As Per Site Requirement Complete All As Specified And Directed. , Supply And Fixing In Replacement Of Ceiling Rose, Surface Bakelite, 65Mm X 50Mm , Two To Three Terminals Complete All As Specified & Directed. , S&F Bell/Buzzer Push 5/6 Amp,Flush Type Complete All As Specified & As Directed , S&F Call Bell Ding Dong Electric Ac, 240 Volt, 50 Hz, Surface Type Complete All As Specified & As Directed. , Supply & Fixing Modular Switch 1 Way 6A,1 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Switch 1 Way 16A,1 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Socket, 6A - 5 Pin Combined 2 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Socket 6A/16A - 5 Pin Combined 2 Module, 240 Volts Complete All As Specified & Directed. , S&F Modular White Cover Plate With Frame 02 Module , S&F Modular White Cover Plate With Frame 03 Module , S&F Modular White Cover Plate With Frame 06 Module , S&F Modular Metal Flush Box 1/2 Module , S&F Modular Metal Flush Box 3 Module , S&F Modular Metal Flush Box 6 Module , Supply And Fixing Led Light Fitting 4 Feet (Cool White) 1 X 20 Watt 220 Volt Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Size From Ceiling Rose Complete All As Directed. , Supply And Fixing Led Light Fitting 4 Feet ( Warm White ) 1 X 20 Watt 220 Volt Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Size From Ceiling Rose Complete All As Directed. , Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Led Tube Rod 4 Feet,20 Watt 220 V Ac Complete All As Specified & Directed. , Supply And Fixing Of Batten Suitable For Fixing Led Lights 20 Watt, 220V, Ac With Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete. , S&F Downlighter Round 18 W (White/Warm White) Recess Mounting Type & Driver Of Various Sizes As Per Site Requirement Incl Integrated Electronic Driver Including Taking Down Old Unsv One Complete All As Specified And Directed , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Cool White) Surface Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Warm White) 220 V Ac Surface Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Cool White) 220 V Ac Recessed Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Warm White) 220 V Ac Recessed Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F Led Lamp 5 Watt, 230W, B-22, providing fixing Not Less Than 0.85 (Min). , S&Fled Lamp 9 Watt, Cool White/Warm White, 230W, B-22 , providing fixing Not Less Tha 0.85 (Min) Complete All As Specified And Directed. , S&F Led Lamp 12 Watt, Cool White/Warm White, 230W, B-22 , providing fixing Not Less Tha 0.85 (Min) Complete All As Specified And Directed. , S&F Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light Made Up Of Innovative Die Cast Aluminium Housing High Power Led As Lighting Source With Ip - 66 Power Consumption 45 Watt Complete Input Voltage Of 150-240 Volt (Nominal Rated Voltage 240 Volt) Complete All As Specified And Directed. , S&F Led Bulkhead Fitting 10 Watt (Endura Ruby) With All Accessories And Including Connenting Up With Twin Core Twisted With Flexible Copper Conductor Cable With Suitable Size Of 230 Volts , 50 Hz Complete All As Specified And Directed. , S&F In Repair Supply And Fixing Post Top Lantern Led Type 20 Watt 230 Watt Volts Ac Outdoor Type With Decorative Post Top For 360 Degree Indirect Light Ip 65 Protection With Impact And Corrosion Resistant Complete With Driver And Lamp Complete All As Specified And Directed.Model No Rubyminipt15wled830psymtopc , S&F Decorative Garden Light Pressure Die Cast Powder Coated Housing With Pc Diffuser Efficient High Output Led With Ip 65 Protecton Of Capacity 10 Watt (Cdl/Ww) With All Accessories And Including Connection Up With Twin Core Twisted With Flexible Copper Conductor Cable Suitable Size Of 230 Volts 50 Hz Complete All As Specified And Directed. , Supplying, Laying, Jointing & Testing Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) With Stranded Aluminum Conductor, 1100 Volts Grade, Of Size 25 Sqmm 4 Core As Per Is 7098 Pt-Ii Laid In Trenches / Ducts / Encased In Gi Pipe / Fixed To Pole Complete All As Directed And Specified. , Supplying, Laying, Jointing & Testing Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) With Stranded Aluminum Conductor, 1100 Volts Grade, Of Size 16 Sqmm 4 Core As Per Is 7098 Pt-Ii Laid In Trenches / Ducts / Encased In Gi Pipe / Fixed To Pole Complete All As Directed And Specified. , S&F In Replacement Of 1100 Volts Grade Heavy Duty Isi Marked Cable Pvc Insulated Stranded Aluminium Conductor One Twin Core Cable Flat Or Circular Of Size 16 Sqmm Served With Inner Sheathing Of Pvc Tape & Overall Pvc Sheathed In Service Connections Complete All As Specified And Directed. , Description All As Per Item No. 49 Above But One Twin Core Cable Flat Or Circular Of Size 10 Sqmm Complete All As Specified And Directed. , Description All As Per Item No. 49 Above But One Twin Core Cable Flat Or Circular Of Size 6 Sqmm Complete All As Specified And Directed. , Description All As Per Item No. 49 Above But One Twin Core Cable Flat Or Circular Of Size 4 Sqmm Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 4 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed On Wall Duly Grouted In Solid Block Wall Or On Wooden Board Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 8 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed On Wall Duly Grouted In Solid Block Wall Or On Wooden Board Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 12 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed On Wall Duly Grouted In Solid Block Wall Or On Wooden Board Complete All As Specified And Directed. , S&F Mcb Spn Having Braking Capacity 10Ka, 32 Amps, 240 V Complete All As Specified And Directed. , S&F Mcb Sp Having Braking Capacity 10Ka, 6 To 32 Amps, 240 V Complete All As Specified And Directed. , S&F Mcb Tpn 63 Amps 415 V Complete All As Specified And Directed. , S&F Mcb Tp 40 Amps 415 V Complete All As Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 63/100 Amps With Ultimate Breaking Capacity 16 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 125 Amps With Ultimate Breaking Capacity 16 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 160 Amps With Ultimate Breaking Capacity 36 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S&F Mccb Dbs Vtpn Type Double Door In Wall / Nitch When Mcbbs ,To Be Used Four Pole And Neutral, 8 Way,415 Volt With Rated Bus Bar ,Suitable For Flush Mounting And Surface Mounting With 160 Amps Copper Bus Bar For Each Phase And 2 Neutral Bar, 2 Earth Bar, And Cable Ties For Cable Managent,Fully Insulated Busbar And Shrouded Neutral Bar ,Improved Pan Assembly For Ease Of Installation ,Prefitted Masking Sheet, Reversible Door For Ip 43 &Ip 54 Dbs With Provision For Dpx3 160 Mccb As Incomer, And Tpn /Spn/Dp/Sp Out Going . Complete All As Specified And Directed. Ip :54 Protection , Excavation In Trenches In Any Type Of Soil Not Exc 1.5 Mtrs Wide And Not Exc 1.5 Mtr In Depth For Laying Of Pipe/ Cables/ Poles Etc And Getting Out Any Type Of Soil Complete All As Specified And As Directed. , Returning Fitting In Any Type Of Soil Including Spreading Leveling Watering And Well Ramming In Layers N.Exc 25 Cm Complete All As Specified And As Directed. , Removing Excavated Soils To A Distance N.Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc 1.5 M Above The Starting Point Complete All As Specified And As Directed. , M & L For Laying Of Fine, Clean Sand (River Sand) Free From Sharp Materials And Stone Particals In Trenches For Cushioning Of Cable 8 Cm Thick Under Cable And 15 Cm Thick Over The Cable Including Gently Punning Complete All As Specified And Directed. Note:- The Total Thickness Of Sand Shall Be Measured 18 Cm After Punning. , Supply And Laying Un-Reinforced Precast.Concrete Cable Protection Cover Of Class Lv, Type-1, Flat Size 250Mm X 150Mm X 40 Mm, Factory Made Of Specified Make , Complete All As Specified And Directed. , Supply And Laying Galvanised Tube Light Grade Isi Marked Of Size 40 Mm Dia Incl All Fittings In Trenches/Fixed On Pole/Wall/Floor Or Laid In Position Including Repairing Of Demolished Cemented Portion Complete All As Specified And Directed. , Supply And Fix In Replacement Electronic Meters Single Phase Temper Proof Lcd Display With Polycarbonate Cover 230 V, 10-60Amp, Accuracy Class-I 50Hz, Conforming To Is 13779, Ip-54, With Parameters To Show Data, Time, Current Reading, Load, Pf, Voltage And Kwh Complete All As Specified And Directed. , Taking Down Of Defective Geyser Of Any Capacity From Different Locations For Repair Including Removing Of Electric Connection, Pipe Fitting Without Any Damage And Refixing The Same After Repair In Same/Desired Location Complete All As Specified & Directed. Note :- The Parts Required For Repair Shall Be Measured Separately Under Relevent Item Of Sch A , S&F Copper/Ss Body Inner Shell Suitable For Water Storage Heater (Geyser) Of 25 Ltr Capacity As Per Sample Including Taking Down Old Unsv Steel/Copper Tank Complete All As Specified And As Directed , S&F Outer Body Of Water Storage Heater (Geyser)Of 25 Ltr Capacity As Per Sample Including Taking Down Old Unsv Outer Body Complete All As Specified And As Directed , M&L For Glass Wool Packing Required For Cover The 25 Ltrs Copper Inner Shell To Avoid The Heat Conduction Including Taking Out Old Packing All As Specified & Directed. , S&F Heating Coil 2000/1500 Watt (Round/Trinangle Type) In Existing Storage Water Heater(Geyser) Suitable For 25 Ltrs Capacity All As Specified & Directed. , S&F Thermostat Range Of 30-80 Degree, As Per Site Requirement, Size As Per Sample All As Specified & Directed. , S&F Non Return Valve Brass Suitable Of 15 Mm Dia Including Taking Down All As Specified & Directed. , S&F Steel Pipe Connection 60 Cm Long Both End Brass Suitable For Hot Water Supply And Screw Down 15 Mm Gi Pipe Complete All As Specified & Directed. , M&L For Replacement Of 12 X 100 Mm Bolts Grouting In Bricks Masonary Wall With 1:4 Cm For Mounting Geyser All As Specified & Directed. , M&L Base Plate Suitable For Hanging Of Geyser Of Capacity 25 Ltr , Taking Down Of Defective Exhaust Fan Any Capacity/Make/Model/Size From Its Original Locations For Repair Including Sealing Of Cable End , Dismantling Blades, Clamps With Bush, Louvers & Motors, Refixing The Same After Repair & Assembling Complete Set In Same Location Etc Including Testing Complete All As Specified & Directed , M&L For Rewinding Of Exhaust Fan Motor 150/225/230/250 Mm Sweep 240 Volt Ac After Dismantling Complete Motor Assay, Bearning, Bushings, Removal Of Burnt Copper Wire, Cleaning Of Core Inserting Proper Insulating Paper In Slots Winding With Copper Wire As Per Existing Gauge And Assemble Complete Set Complete All As Specified And Directed , M&L For Rewinding Of Exhaust Fan Motor 300/450 Mm Sweep 240 Volt Ac After Dismantling Complete Motor Assay, Bearning, Bushings, Removal Of Burnt Copper Wire, Cleaning Of Core Inserting Proper Insulating Paper In Slots Winding With Copper Wire As Per Existing Gauge And Assemble Complete Set Complete All As Specified And Directed , S&F In Repair/Replacement Fan Blade Suitable For Exhaust Fan 150/225/230/250 Mm Sweep Metal/Plastic Body , S&F In Repair/Replacement Fan Blade Suitable For Exhaust Fan 300/450 Mm Sweep Metal Body . , S&F In Repair/Replacement Ball Bearing Of Exhaust Fan Of 150/225/230/250 Mm Sweep As Per Existing Type Complete All As Specified And Directed , S&F In Repair/Replacement Ball Bearing Of Exhaust Fan Of 300/450 Mm Sweep As Per Existing Type Complete All As Specified And Directed , S&F In Repair/Replacement Capacitor Of Cap 1/1.5/3.15 Mfd Sutitable For Exhaust Fan Of 150/225/230/250/300/450 Mm Sweep As Per Existing Type Complete All As Specified And Directed , S&F In Repair/Replacement Of Exhaust Fan Motor Suitable For Exhaust Fans 150/225/230/250 Mm Sweep Plastic/Metal Body. , S&F In Repair/Replacement Of Exhaust Fan Motor Suitable For Exhaust Fans 300/450 Mm Sweep Metal Body. , Material & Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600X600x6 Mm Thick Buried Directly In Ground (Earth Pit Not Less Than 2.25M Deep Below The Ground Level) With Top Edge Of The Plate Not Less Than 1.5Mtr Below The Normal Ground Level Connected To Galvanised Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron.Earth Wire Protected By Gi Pipe 15 Mm Bore(Medium Grade) And Connected To Main Switch Board Or Main Control Board As Directed And As Specified And Shown In Electrical Plate No. 3 Of Ssr Part I (2009) Including Necessary Concrete Pit In Plain Cement Concrete (1:3:6) Type C1, Pre-Cast Reinforced Cement Concrete (1:2:4) Type B1 Cover Slab 40 Cm X 40Cm X 5Cm Reinforced With 8Mm Dia Tmt Bars @ 15Cm C/C With One Handle For Lifting Made Out Of 8Mm Dia Bar, Funnel, Wire Mesh, 20Mm Dia Gi Pipe Medium Grade For Watering, Charcoal Or Coke And Salt In Alternate Layers Including Necessary Excavation And Earth Work In Any Type Of Soil And Testing Complete All As Directed By Engineer-In-Charge. , S&F Wire For Circuit/Sub Main Wiring With 1100 Volts Grade Double Core Pvc Insulated And Unsheathed Cable With Multistranded Copper Conductor 4 Sqmm, On Surface Or Recessed Or Drawn In Pvc Casing Capping/Pvc Pipe Along With 4 Sqmm Single Core Copper Conductor Multi Stranded Cable As Earth Continuity Conductor Complete All As Specified And As Directed.(Note: One Rm Pvc Casing Capping/Pvc Conduit ,One Run Of 4 Sqmm Earth Wire And 2 Run Of 4 Sqmm Cable Shall Be Measured As One Run.) , S&F Wire For Circuit/Sub Main Wiring With 1100 Volts Grade Double Core Pvc Insulated And Unsheathed Cable With Multistranded Copper Conductor 6 Sqmm, On Surface Or Recessed Or Drawn In Pvc Casing Capping/Pvc Pipe Along With 6 Sqmm Single Core Copper Conductor Multi Stranded Cable As Earth Continuity Conductor Complete All As Specified And As Directed.(Note: One Rm Pvc Casing Capping/Pvc Conduit ,One Run Of 6 Sqmm Earth Wire And 2 Run Of 6 Sqmm Cable Shall Be Measured As One Run.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
30.
Defence #11145185 AOC
Bids Are Invited For 43 Akl B-6518576 Pipe Wrench 350 Mm , 43 Akl B6518577 Push Tap Seal , Lv6 Mt1 5350-000036 Valve Grinding Paste Coarse , Lv6 Mt1 5350-000037 Valve Grinding Paste Fine , Lv6 Mt1 Dld Nnk 55786 107 Ancheor Hold Frt Bearing , Lv6 Mt1 4030-000002 Anchors Bars , Lv6 Mt1 6640-003277 Funnel Oil 152Mm Oval , Lv6 Mt1 4730-000060 Nipple Grease Special Bsf Zerk Straig , Lv6 Mt1 4730-000049 1 Nipple Grease Conical Head Straight 1 8 , Lv6 Mt1 4730- 000040 Nipple Grease Conical Head Straight 1 8 Br , Lv6 Mt12 2910-000006 Secondary Fuel Filter 3 Liters , Lv6 Mt3 6220-000052 Mt3 Blackuot Stop Lamp , Lv6 Mt6 2085-4680-0108 Assy Hose , Lv6 Mt6 15815M75J00- 330 Hose Fuel Filter Inlet , Lv6 Mt6 4720720202797 Hose Radiator To Water Pump , Lv6 Mt6 2600-2015- 6305 Fan Belt , Lv6 Mt6 3030-003142 Belt Timing , Lv6 Mt6X-0301650 Poly V Belt , Lv7 Hmv B1417302 Clutch Release Bearing , Lv7 Maruti 09356-75141-600 Hose Water By Pass , Lv7 Maruti 34100M80580 Speedometer Assy , Lv7 Maruti 48806-80000 Boot Assy , Lv7 Maruti 15319M73032 Gasket , Lv7 Maruti 55201M78410 Boot Pin , Lv7 Maruti 09285-00002 Oil Seal , Lv7 Maruti 53401M83311 Cylinder Assy Rear Wheel Rh , Lv7 Maruti 18590M81A10 Sensor Map , Lv7 Maruti 45625M63001 Cover Oil Seal , Lv7 Maruti 13214-82100 Valve Assy Needle , Lv7 Maruti 4110M80041 Spring Assy Front , Lv7 Maruti 09814M00016 Screw Driver Handle , Lv7 Maruti 51300M80900 Booster Assy , Lv7 Maruti 53402M83300 Cylinder Assy Rear Wheel Lh , Lv7 Maruti 5340-135133 Handle Door Inside Rh , Lv7 Maruti 41311M75M00 Spring Assy Rear Lh , Lv7 Maruti 55211M80010 Disc Front Brake , Lv7 Maruti 31612M80030 Bearing Ball , Lv7 Maruti 11394M82000 Seal Water Pump , Lv7 Maruti 09283-48007 Oil Seal , Lv7 Maruti 13731-83001 Joint Assy Universal , Lv7 Maruti 37610M83011 Switch Assy Backup Lamp , Lv7 Maruti 11141M86512 Gasket Cylinder Head , Lv7 Maruti 41781M80000 Bush , Lv7 Maruti 2540-006509 Pad Padal , Lv7 Maruti 08321M0110A Lock Washer , Lv7 Maruti 99570M80000 Tool Box , Lv7 Mg Cvd0982M-99332 Jack With Handle , Lv7 Stln 3120-105958 Bearing Sleeve , Lv7 Stln 2910-008289 Pump Hand Fuel Pump , Lv7 Stln P-3700820 Solenoid Switch , Lv7 Stln 2530-018108 Actuator Spring Brake , Lv7 Stln F0244610 Front Hub Bearing , Lv7 Stln X2003300 Rear Hub Bearing , Lv7 Stln 4320-004125 Pump Hydraulic Ram Hand Driven , Lv7 Stln 5330-72-0475280 Hub Seal Rear , Lv7 Stln 2520-012678 Spider Universal Joint Vehicular , Lv7 Stln F-0530150 Rubber Bush , Lv7 Stln X3016850 Mud Flap , Lv7 Stln X-2202600 Rotory Switch Iec Make 16A 24V , Lv7 Stln 2540-72-0000720 Handle Door , Lv7 Stln Vf 4720-72-0000150 Hose , Lv7 Stln Vf X-7472700 Engine Speed Sensor , Lv7 Stln Vf 2920-72-0201523 Regulator Engine Generator , Lv7 Stln Vf 4720-015646 Hose Non Metallic Dia 1 Hose , Lv7 Stln Vf 4720-72-0000896 Hose Assy Air Duct , Lv7 Stln Vf 2920-005411 Winding Stater Generator Field , Lv7 Stln Vf 2510-007919 Winfd Screen Vehicular Glass , Lv7 Stln Vf F-0845614 Clamp Hose , Lv7 Stln Vf X-1916010 Radiator Pipe , Lv7 Stln Vf X-7820800 Sun Visor , Lv7 Stln Vf 6220-72-0000172 Light Marker Clearance , Lv7 Stln Vf X-7820900 Sun Visor , Lv7 Stln Vf F-8358100 Ignition Relay Alt F7819400 , Lv7 Stln Vf X-4704111 Ring Spanner 21X23 Metric Total Quantity : 1132
Contract Date: Ref. Documents Contract Value : 7.24 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
31.
Power #11144553 Technical Bid
Tender for Supply Of Electrical Spares And Minor Stores/Hardware Items From The Original Equipment Manufacturer, Their Authorized Dealer/Local Representative Or Local Ssi Units Registered Firms/Suppliers Already In The Trade For The Year 2026-27 , Hardware Fitings And Accessories,Clamps And Connectors For Acsr /Aaac Conductor , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Hardware Fitting For Aaac Panther Conductor 37/3.15Mm Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Hardware =7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Single Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Hardware = 9000Kg Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Suspension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Compression Type Repair Sleeve Suitable For Aaac Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Zebra/Moose Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , 4R Stock Bridge Type Vibration Damper Suitable For Aaac :Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Aaac Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , Mid Span Compression Joint For Acsr Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Zebra (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Moose (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Zebra To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Aaac Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Disc Insulator 70Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 70Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Without Anti Fog(Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Gi Nuts And Bolts Of Sorts (16Mmx35mm/ 40Mm/45Mm/50Mm & 65Mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx75mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx50mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (12Mmx50mm) Heavy Duty , Aluminium Cable Tray Of Size 400 Mm X3000 Mm , Aluminium Cable Tray Of Size 300 Mm X2500 Mm , M.S. Angle Iron Of Size (45X45x5)Mm , M.S. Angle Iron Of Size (50X50x5) Mm , Steel Tor Of Dia 8Mm , 10Mm, 12Mm For Cable Ducts , Spring Washers 16Mm Heavy Duty , G. I Wire Swg No. 8/ 4.06Mm Dia , Red Oxide Enamel Paint (Asian, Nerolac/ Berger) , Al. Paint (Asian, Nerolac/ Berger) , Smoke Grey Enamel Paint (Asian, Nerolac/ Berger) , Yellow/White Paint (Asian, Nerolac/ Berger) , Cement Permier (Asian, Nerolac/ Berger) , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T-Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975 Bimetallic Ct- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther With Clamp Sutitable For 132/33Kv CtS Of Ae Mumbai, Sct Gaziabad, Bhel Vidhyut Control Andhra, Mehru Bhiwadi/ Laxmi Engg Bhopal, Jyoti.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132/33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , P.I. Clamp For Acsr Zebra Conductor , P.I. Clamp For Acsr Panther Conductor , P.I. Clamp For Acsr Moose Conductor , P.I. Clamp For Acsr Moose Conductor , Twin Bushing Clamp Acsr Moose For 132/33Kv Transformer 1200Amp Without Poles , Twin Bushing Clamp Acsr Moose For 220/132Kv Transformer 1200Amp Without Poles , Isolator Jaw 1600Amp For 33Kv Isolator , Isolator Jaw 2500Amp For 33Kv Isolator , Isolator Jaw 1600Amp For 132Kv Isolator , Isolator Jaw 2500Amp For 132Kv Isolator , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , Jumpers Cone For Acsr Panther , Jumpers Cone For Acsr Zebra , Spacers For Acsr Zebra , Spacers For Acsr Moose , Spacers For Acsr Panther , Earth Wire Tension Clamp , Electrical Items And Spares , Shunt Capacitor Fuse 40A With Spring Complete Assembly , Silcagel Crystal Size 8- 8 Mesh , Silcagel Breather Box 10Kg , Aluminium Tape , Chemical Jelly , Grease , Distilled Water , Transformer Oil Sampling Bottle , Welding Electrodes Swg 8No As Per Is: 814 Of 2004 , Welding Electrodes Swg 10No As Per Is: 814 Of 2004 , Search Light With 300-500Mtr. Focus Make Flash, Equivalent Etc , Led Flood Light Complete 90/100Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 140/150Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 1900/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Street Light Fitting 190/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Lamp 9 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Led Lamp 15 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 18 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 45 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Lamp Holder Pendant/Angular (Anchor,Havells,L&T,Philips/Reputed Make) , Led Tube 4 Pin 18 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Mcb 5-10 annual periodical maintenance Two Pole (Havells, Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Two Pole (Havells,Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 32 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 63 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mccb 100 Amp, 4 Pole, Ics= 100% Icu (Havells, Standard, L&T) , Mccb 200/400/600Amp,4Pole,Ics=100% Icu(Havelles,Standard,L&T) , Main Iron Clad Switch Tpn 415V,400A , Rubber Mat 1Mtr X2mtr= 12Mm Thick , Cable Ferrules A To Z And 0 To 9 , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Copper Mesh (30Cmx5cm) , Copper Wire 8Swg , Copper Thimbles 8Mm , Copper Thimbles 10Mm , Alumunium Thimbles 2.5 / 6 Mm , Alumunium Thimbles 8 / 10 Mm , Fhelmet , Starter 36Watts , Tube Four Pin 36 Watts , Choke 36Watts , Rubberized Cork Sheet 6Mm , Rubberized Cork Sheet 10Mm , O-Rings For Bushings/Inspection Plates Of Transformer 5Mm-10Mm Diameter , Rubber Sealings For Marshalling Kiosks/Control & Relay Panels , Cooling Fans Of 3 Phase 50Mva , 33Kv Vaccum Interrupter Suitable For 33Kv Vcb Of Bhel,Abb,Gec Alstom,Seimens,Megawin, S&S Make , Thermal Overload Relay Seimens Make With Range 0.8-1.2 annual periodical maintenance , Thermal Overload Relay Seimens Make With Range 1.2A-2.5 annual periodical maintenance , Thermal Overload Relay Seimens Make Of 4A Max With Range 0.1-1Amp And 1.5A-1.2A , Mn2 Thermal Overload Relay With Start And Off/Reset Relay Of Range 0.9-1.5A L&T Make , Relay 500V,2A, Fuse 6Amp. Mn2 Make L&T , Relay 415V,3.2-5A,Class 10A Mn2 Makesiemens 3Ua50 00-1F , Relay 415V,Lth=10A,Le=4A Mn-A1 Make L&T , Dc Change Over Relay Dcco, Make Abbrxme-1-Rk221-052-Annrk711004 , Dc1 Supervision Make Abb Tsr-In352 , Anti Pumping Relay Make Schrack/Abb Or Equi , Auxillary Relay, Voltage Selection Relay 75A, Rxpsu14n-Imyn563646-Dau, Aux Voltage:110V Dc, Case Size:2S 12C, Contacts:13No+1Nc, Reset Type:Electrical, Flag:Yes, Make Abb , Auxillary Relay, Tc-1 Supervision Relay195, 7Pj1321-5Aa210aa0, Aux Voltage:24-23V Dc, Contacts:2C/O, Reset Type:Self Make Siemens , Numerical Relay, Dir. O/C & E/F Protection Relay67/67N 7Sj6611-5Eb90-1Fgo-Lor, Aux Supply:110/250V Dc, Case Size:1/3 19,16 Bi, 7 Bo,1 Life Contact,4*I, 4*U,Ct:1A, Vt:110V/220V,50Hz, Iec61850, 100 Mbit Ethernet, Electrical, Double, Rj45-Connector Make Siemens , Thermostat Make Apt/Veilco/Eq , Auxiliary Air Break Contactor Of Ac2/Ac3 Duty Cycle Number Of Poles 03, Voltage 415V, annual periodical maintenance 0-2 A, Contacts 2No+2Nc,Make Siemens , Magnetic Control Contactor Make Andrew Yule Power 44W Volt 110V Dc Ith 10A Is 13947 Iec 947 , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mnx12 Make L&T , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mna1 Make L&T , Contactor 415V, 20Amp 3Tf31 01-0A Make Siemens , Contactor 415V, 9Amp Lth 10Amp,Le 4Amp Mnx9 Make L&T , Auxillary Contactor 3Th3022-0B-F4, Aux Supply:110V Dc, Contacts:20O-2Nc 89Ax Make Siemens , Cooling Fans 3 Phase Motor,415V,560Watt,900Rpm,0.9Amp/1Amp(Size 600Mm) , Cooling Fans 3 Phase Motor,415V,700Watt,550Rpm,1.5Amp(Size 600Mm) , Digital Oti 90-250V Ac/Dc, Range 0-150Degree Make Precimeasure Control Banglore , Digital Wti Meter Make Precimeasure Control Banglore , Megawatt Meter , Digital Megawatt Meter, Bezel Size: 96*96Mm, 4-1/2 Digits, Aux Supply:110V Dc, Accuracy:0.5, Ctr:1200:800-400/1A Ptr:33Kv/110V Make Ae , Mvar Meter Digital Mvar Meter, Bezel Size:96*96Mm, 4-1/2 Digits, Aux Supply: 110V Dc, Accuracy:0.5, Ctr:1200-800-400/1A Ptr:33Kv/110V Make Ae , Ammeter Digital Ammeter, Bezel Size:96*96Mm, Aux Supply:110V Dc, Accuracy: 0.5, Range:1200-800-400/1A, Inbuilt Selector Switch Make Ae , Selector Control Switch Er Make 1224 Swiso , Digital Ac Ammeter,Makeae Digital 4, Range 0-600A, Ct Ratio 600/1A, Size 130X130 Mm. , Electronic Hooter, Aux. Supply 110V Dc, Freq. 48-63 Hz, O/P95-105 Db Size 96X96x82 Mm. , Lubricator Make Sae80w/90 Type Oil , Glass Sleeves , Crc Bottle , Teflon Tape , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Fan Contactor Seimens Ice 158.1 Auxiliary Contactor 2No+2Nc & 4No+ 4Nc , Seimens 3Ta6702 2 To 10A, Auxilairy Contactor 3No+2Nc,Cs3-P Iec947 En60947 V=6Kv Ac-1 690V-1A Ac-15 , Solder Flux , Single Core 300Sq Mm 33 Kv Voltage Grade,Al Conductor, Pvc Insulated, Sheathed, Armoured, Xlpe Cable Likely Make Havelles Etc , Pvc Unarmoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 4 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 6 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 8 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 10 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 12 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 16 Core , Pvc Copper Wire 1 Mmsq , Pvc Copper Wire 1.5 Sqmm , Pvc Copper Wire 2 Sqmm , Pvc Copper Wire 4 Sqmm , Pvc Copper Wire 6 Sqmm , Copper Glands 19/25/32Mm , Switch 5A , Switch 15A , Socket 5 Pin, 5A , Socket15 Pin, 5A , Fan Regulator 10A , Dp Switch 32A , Pvc Tape Roll , Indicating Pygmy Lamp 220V/110V Dc, Pin Type / Screw Type , Semaphore Indicator For Isolator S89a Ntc12, Aux Supply:110V Dc, With 3Kohm, 6W External Resistor Make Dav , Push-Button & Indicating Lamp For Ann. Accept 3Sb50 00-0Ab01+ 3Sb54 00-0A, Normal Actuator With Plastic Front Ring And Black Holder Contact (1N0+1Nc) , Auxillary Switch 8No+ 8Nc Make Shirka/Shubhada/Eq , Local Remote Switch Make Shirka/Switron/Kaycee , Rotary Switch, Local Remote Switch 8 Ways, Handle:Pistol Grip, Position:Local/Remote, Stay Put, (Local-4Ways, Remote-4 Ways), 25A; Lockable Type, Bezel Size:75 Sq.Mm , Limit Switch 3Se3 023-0A, Contacts:1No+2Nc Make Siemens , Control Switch Bcs 3 Position ,Pistol Grip 16 Ways Make Switron , Control Switch Bcs 3 Position ,Pistol Grip 20 Ways Make Switron , 3 Core 95 Sq Mm 11Kv Xlpe Cable , Sf-6 Gas Cylinder Of 9Kg , Sf-6 Gas Cylinder Of 11Kg , Nitrogen Cylinder Of 16Kg Containing 9Kg Gas , O2 Cylinder Refilling , Anti Rodent Device , Control Switch For Panels Reputed Make , Hrc Fuse 2Amps , Hrc Fuse 4Amps , Hrc Fuse 6Amps , Hrc Fuse 10Amps , Hrc Fuse 10Amps , Hrc Fuse 32Amps , Hrc Fuse 32Amps , Hrc Fuse 100Amps , Fuse 3Nw20nnsf+3Nwns10, Aux Voltage:110V Dc, Rating:10A Make Siemens , Fuse 3Nw20nnsf+3Nwns4, Aux Voltage:110V Dc, Rating:10A Make Siemens , 33Kv Phase Limb Of 33Kv Circuit Breaker (Abb Make) , Breather Box For 133.33 Mva/160 Mva/150Mva, 220/132 Kv Transformer (Bhel/Abb Make) , Breather Box For 50 Mva,132/33 Kv Power Transformer (Bhel/Cgl/Ece/Emco Make) , Numerical O/C And E/F Relay Make:Easun Reyrolle , Model: Mit 114,Poles:4No,Volt: 43-280V Dc,Amp:1A , Numerical Differential Relay For Power Transformer Protection Make Ashida,Er/Reputed Make , Master Trip Relay B24,110/125 V Dc Make Er/Reputed , Master Trip Relay B24,220 V Dc Make Er/Reputed , Master Trip Relay 86, Rxmvb2-1Myn563035-Ad Make Abb , Trip Relay Supervision Relay 95 Tsr-1N352-001-As, Make Abb , 33Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt :33Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 66Kv Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 66Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A , 132 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 132Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 220 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt : 220Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 2 Pole Heavy Duty Rotary Switch With Off 5Amp Make Key Cee Equivalent Etc For C&R Panel , Shunt Tripping/Closing Coil 110V/220V Dc, Suitable For 33Kv Vcb Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make Etc , Shunt Tripping/Closing Coil 110V/220V Dc,Suitable For 66Kv Sf6 Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make , Spring/Charging/Closing Coil 220V/110V Dc, Suitable For 33Kv Vcb Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 33 Vcb Of Abb Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 132 Sf6 Of Abb Make , Tnc Switch 110/220V Dc 4Ways , Tnc Switch 110/220V Dc 8Ways , Tnc Switch 110/220V Dc 12Ways , Vrla Battery 12V,80/160Ah Along With Charger , Space Heater Sh100w240, Rating:100W 240V Ac Make Apt Control , Resistor Unit For Master Trip Relay 86 Rxtma-1Nrk711004-Aa Make Abb , Geared Motor For 100-130V Dc/Ac 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Ac For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Spring Charge Motor 230V Ac/Dc , 1.8A, Type Sg105, Insulation Class B, Rpm 60 For 36Kv Vcb Make Agni/Shreem/Reputed Make , Spring Charge Motor 230V Ac/Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Spring Charge Motor 230V Ac/Dc 2.5A For 132 Kv Sf6 Circuit Breaker (Siemens Make) , Auxilliary Contactor 110V Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Operating Coil 24V Dc maintenance of For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 maintenance of Opening Coil 48V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(110V-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(220-250V Dc/220V-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shunt Closing Release-Mc 24V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mc Closing Coil(48V Ac-Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(110-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 24V Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 48V Ac- Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly(110-132V Dc/110-127V Ac) Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mu Coil Assembly(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 24Vcc Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(48Vca-Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(110-127Vca/110-132Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 220-250Vca/220-250Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shock Absorber Assembly For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Acsr Zebra Conductor , Acsr Panther Conductor , Acsr Moose Conductor , El3 Drive Complete(Operating Mechanism) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Transformer Oil , Motor Operated Change Over Ac240v/Dc220v 100 annual periodical maintenance (Breaker Type) , Singhle Phase 50 C/S, Outdoor Metal Oxide Gapless Type ,30Kv(Rms) Surge Arrester Including Surge Counter/Monitor,Insulating Base Plate And All Associated Assessories Auxilliares , 33Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95Kvp Dry Lightning Impulse Withstand Voltage ± 170 (Kvp) , 132Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 275Kvp Dry Lightning Impulse Withstand Voltage ± 650 (Kvp) , Single Phase 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries. , Single Phase, 50 C/S 145Kv Current Transformers (900-600-300/1-1-1-1-1 A Or As Per Site Specifications), 31.5Ka For One Second, Rated Dynamic Current 100Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S 132Kv Capacitor Voltage Transformers (132/√3) Kv/ (110/√3)V, One Min Power Freq Withstand 275Kvrms , Single Phase, 50 C/S 36Kv Current Transformers (1200-600-300 /1-1-1 A Or As Per Site Specifications) , 25Ka For One Second, Rated Dynamic Current 25Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S Outdoor 33Kv Pt (33/√3) Kv/ (110/√3)V With Highest System Voltage36kv, One Min Power Freq Withstand 70Kvrms , Marshalling Kiosk With Kiosk Frames Mild Steel Structural Sections For Pressed And Shaped Cold-Rolled Sheet Steel, Thickness Not Less Than 2.0 Mm. Frames Shall Be Enclosed In Cold-Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Doors And Covers Shall Also Be Cold Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Complete Structures Shall Be Rigid, Self Supporting, Free From Flows, Twists And Bends. Dust And Vermin Proof Construction And Shall Be Provided With A Degree Of Protection Of Ip: 55, With Copper Bar Earthing. Finishing Paint On Panels Shall Be Of Shade 692 (Smoke Grey) Of Is: 5. The Inside Shall Be Properly Stoved. The Paint Thickness Shall Be At Least 50 Microns , Single Phase 36Kv 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries , T&P Items And Safety Equipments , Turn Table For Acsr Panther/Zebra Conductor With Capacity Of 3Mt Made Of Mild Steel With Double Ball Bearing Likely Makes Pee, Zi, Honeywell, Burma Etc , Four Sheeve Pulley Steel Frame Forged Swivel Hookwith Capacity Of 5Mt As Per Is 8610 Pulley Material And Ball Bearing Of Gun Metal Bush With Open Type Pulley Isi Mark Suitable For 12Mm Steel Rope , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/3.15Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/2.88 Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Zebra Conductor 54/7/3.18Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp For Earth Wire Size 7/3.66Mm Groove According To Size Of Earth Wire Bolts Of High Tensile Steel Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Galvanized Pulley Size 6 Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing. , Al Alloy Snatch Roller Pulley Size 8Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Roller Pulley Size 6Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Earthwire Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Tool Kit , D-Shackle Heavy Duty , Chain Block Pulley Heavy Duty 5 Ton , Avo Meter Likely Make Motwani, Waco, Riken Etc , Hook On Meter Likely Make Motwani, Waco, Riken Etc , Insulating Hand Gloves Make Crystal Etc Tested For 220 Kv, 132 Kv , 33Kv Level , Safety Helmet Isi Marked , Safety Belt Isi Marked , Safety Vest Isi Marked , Rain Coat Of Duck Back Make Etc , Safety Shoes Of Reputed Make Etc , Fixed Piller Drill Machine 40Mm , Polypropylene Rope ½, ¾& 1 / Garware Make , Manila Rope ¾ & 1 Dia , Steel Wire Rope Sling 16Mm Dia Isi Make 2 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 5 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 10 Mtr. Long Heavy Duty , Steel Wire Rope Of Dia 16 Mm , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 220Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 132Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 33Kv Voltage Level , Hydraulic Conductor Cutter , Hydraulic Compressor Manually Operated For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Hydraulic Compressor Motorised For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Compressor Die Sets Suitable For Above Hydraulic Compressors , Drum Lifting Jack Mechanical 3 Ton Capacity , Single Sheeve Pulley Both Open And Close 5 Ton Capacity , Double Sheeve Pulley 5 Ton Capacity , Three Sheeve Pulley , Petrol Chain Saw Cutter , Earthing Roller , Equilizer Pulleys 10 Ton , Earth Wire Pulley , Single Sheeve Roller Aluminium, Rubberized Dia 300/400 Mm , Single Sheeve Roller Aluminium, Dia 450/600 Mm , Twin Aerial Roller, 150Mm (Rubberized) Aluminium , Twin Aerial Roller, 150Mm (Rubberized) Nylon (P.P) , Patta Clamp , Kitto Clamp , Turn Buckle Capacity 5 Ton , Joint Proctector For Various Conductors , Sagging Winch Machine 10 Ton , Single End Socks , Double End Socks , Earth Wire Socks , Power Winch Machine 5 Mt , Sag Plate , Single Pulley 150Mm Dia (Aluminiun/ P.P) , Automatic Clamp For Conductor/ Opgw , Crow Bar, 30Mm To 32 Mm , Derrick Pole, S-Type Roller , Air Compressor With Ac Single Phase Air Cooled 12 Cfm Compressor And Tank Pressure 100 Psi Make Maxair/Reputed Make , Paint Spray Gun 45Psi , Old Cotton Saree , Digital Mutltimeter (Mutli Functional Meter) , Military Grade Binocular (Reputed Make) Magnification Between 7X To 12 X And Objective Lense Diameter , Axe/Sickle , Professional Chain Saw 58Cc, 20 Inches, 3.75 Hp , Bush Cutting Machine Heavy Duty (Reputed Make) , Meggar , Earth Tester , Digital Insualtion Tester , Earth Test Field Kit , Oil Bdv Kit , Thermovision Camera Having Resolution 640*480, Wavelength 8-14Um, Thermal Sensitivity =0.05°C , Automatic Identification Lens With Manual/Electric/Automatic Focusing, Fov- 25°X19°; High Brightness Sunlight Screen, With 4X Digital Zoom, Hdmi Output, 500Million Pixels, Laser Positioning Points Displayed On The Image,With 32Gb Memory Space, Video Recording, Temp Range: -2O Degree To 650 Degree Centigrade, Having Rechargaeble Liyhium Ion Battery , Primary Injection Kit With 1000 Amperes Rating Accuracy ±0.5% Power Supply(Ac) 220V±10%·25A, 50Hz/60Hz Or 110V±10%·50A, 50Hz/60Hz Current Output (Ac) 1000A·5V Or 500A·10V Capacity 5Kva The Current Output Waveform Distortion ≤5% Dual Protection Overload Electronic Protection And Software Protection Range 0-1100A Resolution 0.1A, Accuracy 0.5%, Secondary Measurement Range 0-6A Resolution 0.001A, Accuracy 0.5%, Current Duration 1000A Range 1000A 2-3Minutes 500A 3-6Minutes 500A Range 500A 2-3Minutes Continuous Output 0-400A With Timer Range 0.0001~999.99S Resolution 0.001S Accuracy 0.2% ±2 Words Standard Standard Iec61010-1;Iec 61326-1 Communication Port Rs232 Cable Length 2X6m, 70Mm² , Cgi Sheet , Spanner Set , Fire Fighting Equipments , Refilling Of Dry Powder 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 15Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 25Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 50Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 2Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 5Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Mechanical Foam Type 50 Ltrs (Make Freeze Fire/Reputed Make) , Refilling Of Co2 Type 4.5 Kg , Refilling Of Co2 Type 10 Kg , Refilling Of Co2 Type 12.2 Kg , Refilling Of Co2 Type 22.5 Kg , Hose Pipe For Dcp 10 Kg , Hose Pipe For Dcp 25 Kg , Hose Pipe For Dcp 50 Kg , Hose Pipe For Abc 2 Kg , Hose Pipe For Abc 5 Kg , Hose Pipe For Abc 10 Kg , Hose Pipe For Mechanical Foam Type 50 Ltrs. , Hose Pipe For Co2 4.5 Kg , Hose Pipe For Co2 22.5 Kg , Wheel Set For Dcp 25 Kg , Wheel Set For Dcp Co2 22.5 Kg , Wheel Set For Dcp/Mechanical Foam 50 Kg , Union Cap For Dcp 10Kg , Union Cap For Dcp 25Kg , Union Cap For Dcp 50Kg , Dry Powder Fire Extinguisher 25 Kg Trolly Mounted Filled With Bc Dry Powder Fitted With Hose Pipe/ Nozzle Is No: 10658 Used On B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Type Fire Extinguisher 6Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Typefire Extinguisher 9Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Carbon Dioxidetype Fire Extinguishers Seamless 4.5 Capacity Wheel Type Fitted With Isi Marked Value, Hose/Horn Filled With Co2 Gas Applicable On Class B,C Fires Is 15683 Make Cease Fire,Savemax,Reputed Make , Mechanical Foam 50 Ltrs. Fire Extinguishertrolly Mounted Filled With Afff Concentrate Fitted With Hose Pipe/ Nozzle Is No: 13386 Used On A & B Class Of Fire Make Cease Fire,Savemax,Reputed Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
32.
Housing Urban and Rular Development #11118160 AOC
Tender For Modular Operation Theatre Items At Sadar Hospital, Jamtara At Jamtara For The Year-2025-26 , Wall And Ceiling Cladding (Approved Makes: Jindal/Tata/Essar) Prefabricated Wall & Ceiling Prefabbicated Modular Operating Theater Using Ppgi Puf Panel (Both Wall & Ceiling) Providing Of Pre-Fabricated Modular Operation Theater With Ppgi Puf Pannel Filled With Puf Of 40 Kg/Cubic Meter (40D) Having Required Mechanical Strength And Better Thermal Insulation Which Saves Energy Construction The Panels Joints Are Properly Cam Locked & Revisited Which Provides A Seamless Sub- Structure Which Again Sanded To A Smooth Finish. Approx. Thickness For Wall 50 Mm, Raiser 40 Mm. And Ceiling 30Mm. , Laminar Air Flow System Supply Installation Testing And Commissioning Of Ceiling Filtration System 2400 X 2400 Mm. The Ceiling Filtration System Shall Be 2.40 Meters X 2.40 Meters And Will Be Integrated With The Adjacent False Ceiling. The Ceiling Shall Be Constructed With A Plenum Box Supplied With Conditioned Air From The Central System Via 8 Nos.Hepa Filters (European Norm En1822:2009; Class H14; Dop 99.97-99.9999% Efficincy For 0.3 Micron Particles) With Pressure Drop Of 300 Pascals At Its Nominal Flow Rates (Supplied With The Plenum), Mounted On The Exit From The Supply Ducting. , Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Weled With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Hermetically Sealed Sliding Door System Fabrication Supply, Installation, Testing & Commissioning Of Sliding Type Hermetically Sealed Ot Door Having High Density Partical Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Size:1800 X 2100 Mm.(Wx H). Automatice Doors: Provided With Radar Switch- 2 Nos., Foot Switch Nos. And Photocell Sensors (Anti Crush Feature) & As Per Tech. Specs.Attached. Automatice Doors Size:(1800 X 2100 Mm.) , Peripheral Lights Supply Installation And Commissioning Of 42W Bottom Opening Room Fixture With Ip 65, Led Make Should Be Nichia/Seoul5 Sdcm, Own Make Bis Certified Islocated Driver, Flicker Free, Class2 Selv Driver, Operating Temperature:-100C To 450C Operating Voltage Range:140-270V, Surge Protecction 3.5 Kv, High Effciency Driver:80-85%, Low Voltage Cut Off Below 130V, Output Short Circuit Protction, Fixture Made Up Of Ms Power Coated White After Phosphochromate Treatment Provided As Standard With Sheet Thickness Of 1.2 Mm. Diffuser Of High Impact Polycarbonate Opal Diffuser With Thickness 1.5Mm For Glare Freeuniform Light Distribution, Power Coating: 60Microns, Lamp Source: High Efficiency Long Life Led Package In Integral Module To Ensure Better Uniformity, Average Life L70b50: 50000 Hours,Thd10%,95, System Efficacy 95-100 Lm/W, Cri80, Ip65, Ik05 Impact Rating, Dimension Will Be , Surgeon Control Panel Supply, Installation, Testing & Commissioning Of Operation Theatre Control Panel Membrane Type: Time Day Clock Time Elapse Clock General And Rgb Lighting System Conntrol (Peripheral Lights And Plenum Lights With Dimming) Medical Gas Alarm Panel 5 Gas- Low, Normal And High Pressure With Sequencing As Per Htm 02 01 Hand Free Telephone Set With Speaker Temperature & Humidity Indicator With Controller Hepa Filter Status Module Room Pressure Indicator/ Differential Pressure Indicator , X-Ray View Screen Supply Installation, Testing & Commissioning Of Twin Plate Led Xray Viewing Screen: Size:940 X 640 X 50 Mm. Approx With Viewing Area, Two Plate X-Ray View Screen (120W), Led Based Technology With Colour Temperature6000k And Lamp Life50,000 Hrs And Brightness In Excess Of 4000 Lux. , Writing White Board Supplying & Fixing Of Sturdy Writing Operating List Board: Made Of Ceramic Surface Having Magnetic Properties And Should Be Flushed To The Wall Of The Operating Room Size 940Mmx 640Mmx 50Mm , Surgeon Pendant Providing & Fixing Of Ceiling Mounted Single Arm Pendant Systems For Surgeon: The Weight Carrying Capacity Of The Arm Should Not Be Less Than 180 Kgs. Load. There Should Be 5 Or 6 Nos. Equipment Loading Shelves. Double Column Of 1000Mm. Single Arm Pivot Range Minimum 900 Mm. Or Above. The Brake (Electromagnetic) Supplied With Indian Origin Multipin 6/16 Annual Periodical Maintenance Electrical Switch+Socket-5Nos. It Should Have 2 No. Rj 45 Data Socket. It Should Have Provision For 06 Gas Outlet Points 2 Oxygen 1 Sa7 1Co2 1 Vacuum Capable Of 340 Degrees Of Rotation. Medical Gas Terminal Units Shall Be Provded By The Mgps Vendor And Shall Be Installed In The Pendant. Usfda , Anesthesia Pendant Ceiling Mounted Rigid Pendant Systems For Anaesthesia: Single Arm Motorized Type Pendants Made Of Aluminum, Powder Coate Dimensions: Double Vertical Column 1200 Mm. Vertical Lift:600 Mm. Horizontal Arms- Total 1000 Mm. Pendant Should Be Prepiped Provided With 5 Nos. Medical Gas Outlets. Outlets Shall Be Connected To Dual Circuit Being Provisioned For All Ozygen 2 Outlets. Nitrous Oxide 1 Outlets Vacuum 1 Outlets. Medical Air 1 Outlets Agss 1 Outlet Colour Coded High Pressure Tubing For Each Gas With Nist Connectors At Ceiling Provided With Prewired 10 Nos 6/16 Amps Sockets And Two Data Sockets Rj45 Instrument Loanding Capacity 180 Kgs. Shelves: Two With Handle And Two Rail Each With Capacity Of 40 Kgs. Drawers One With Handle And Twe Rails Load Capacity 40 Kgs. Swiveling Stainless Steel Vertical Pole , Air Conditioning System: Ahu Supply, Installation & Commissioning Of Air Handling Unit Make: Vts (8.5Tr) (Out Door Unit Make: Blue Star / Carrier) , Aluminum Duction 22 Gauge With Curves & Bends Where Indicated For Easy Flow Of Air Tight By Applying Silicon Sealant After Fabrication. Hangers Will Be Provided To Ducts & Will Be Suspended Be Means Of G.I. Coated Rod & These With Not Be More Than 2.5 Mtr. Apart. Thermal Insulation With 19Mm. Xpe With Aluminum Foil For Supply & 13Mm. Xpe Return Air Ducts. Joints Will Be Lapped With Nitrile Tape For Better Insulation. (Laminar To Ahu & Return Air In All Four Corners) Ahu To Be Placed Near Ot, Not More Than 6 Meters. , Dustbin (Trio) , Storge Unit: Storge Unit: 1 Mm. Thick Stainless Sheet 304. The Storge Unit Should Be Divided 4 Equal Parts And Eachpart Should Have Indivdual Swing 8 Mm. Toughened Glass Door With Quality Stanless Steel Self- Closing Hinges Capable Of 180 Degree Swing Out And Secure Locking System. Each Part Will Be Provided With Removable Stainless Steel Racks Made From½ Circular ( Outer Diameter) Seamless Stniless Steel 304 Tubes Of 1 Mm. Thickness Placed At Intervals Of 1.5 Center To Center. The Overall Dimension Of The Stroge Unit Shall Be 1500 Mm. (Width) X 2100 Mm. (Height) 350 Mm. Depth Being Variable To Suit Architectural Layout. , Supplying, Installation, Testing & Commissioning Of F Floor Mounted, Scrub Station: Compact Surgical 2 Bay Scrub Sink Designed For Use In Ot Complex. Each Fixture Fabricated From Heavy Gauge 1 Mm. Thick Type 304 Stainless Steel Of Seamless Welded Construction, Polished To A Smooth Finish With A Front Access Panel Which Should Include, Stoppers And Strainers. Hands Free Operation Should Include Infra-Red Sensors With Built-In Range Of Adjustment. Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature. User Defined Setting Of Approximately 1 To 3 Min Should Be Available. (Size 1500Mm. X 675Mm. X 1105Mm. For 2 Persons , Electrical Db Supply Installation Testing And Commissioning Of Electrical Distribution Board: Should The Trandformers, If Any, Mains Failure Relays, Electrical Distrition Equipment And Circuit Protection Equipment For All Circuits Within The Operating Theatre. All Internal Wiring Should Terminate In Connectore With Screw And Clamp Spring Connections Of The Clip-On Type Mounted, On A Din Rail And Labelled With Indelible Propritary Lables, Individual Fuses Or Miniature Circuit Breakers Should Protect All Internal Circuits. , Pressure Relief Damper Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Relief Dampers: Suitably Sized Air Pressure Relief Damper Should Be Placed Endabling Differential Room Pressure To Be Maintained.Counter-Weight Balancing System Should Be Prvided In The Prd To Maintain Positive Pressure Inside The Operation Room , C-9001 Supreme, Sliding Top Electric Table , C-9001 Supreme, Sliding Top Electric Table Led Operating Light Led Operating Light Having Following Specifications:- Maximum Luminance (1M): 160,000+160,000 Lux At 1 M Distance, Electrical Power: 150+90W, Power Consumption 2 X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1 X 3600/ 1 X 3300, Recommended Room Height At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm/650 N, Light Body Weight 9.2 + 7.5 Kgs, Light Body Depth: 1 X 130 Cm / 1 X 140 Cm, Air Shielding Surface 2 X 330 Cm2 Transformers: 2 X 450Va/ 230V/26V, Brightness Regulator 2 X 20- 500Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Done Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs: , Uv System: Uv Rays Are Very Effective In Killing A Large Number Of Pathogenic Organisms Of Bacterial, Viral And Fungi Commonly Seen In Operating Theaters Such As Pseudomonas, Clostridium Difficile, Mrsa And Vre , De- Fumigation System: Fumigation In Operation Theatre Is A Process Of Gaseous Sterillization That Is Used For The Killing Of Micro-Organisms And Prevention Of Micro-Organisms And Prevention Of Microbial Grwth In The Air, The Surface Of The Wall, Or The Floor1.000 De-Fumigation Control Panel Is Installed Outside The Operation Theatre To Monitor The Room Pressure And To Start The De- Fumigation System From Outside The Operation Theatre, It Will De-Fumigation The Theatre In A Given Time And Will Switch-Om The Ahu To Increase Operation Theatre Pressure Without Operating The Surgeon Control Panel , Ot Corridor Area & Ot Complex With Per And Post Area Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Welded With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Antibacterial / Antifungal Paint Providing And Applying Antibacterial Paint The Internal Surface Of The Room Walls Will Be Sprayed With Water Based Liquid Plastic Wall Glaze Or Equivalent Anti- Bacterial Paint, Approved By The Architect To A Mimnimum Dry Film Thickness Of 300 Microns. The Plastic Coating Will Overlap The Floor Covering Ceiling System And Doorframes By 25 Mm. To Provde A Continuous Sealed Surface. The Plastice Coating Will Be Non- Reflective And The Colour Will Be Submitted To The Architect For Approval. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Jun 15, 2026 Contract Value : 1.21 Crore
Government Departments No of Bidders 4
33.
Housing Urban and Rular Development #11116820 AOC
Tender For Proposed Furniture For Upgradation Of 30 Bedded Hospital To 50 Beded Hospital Sub District Hospital At Atpadi Tal-Atpadi Dist-Sangli.-1 Providing & fixing wall paneling in 19 Milllmetre and & 6 Millimetre thick Plywood finished with 1 Millimetre laminate for all exterior sides, with approved shade as per detailed drawing & design.SS hinges.SS handies. TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 2 FULL HEIGHT PARTITION - Providing & fixing wall partition made in 19+19 Millimetre ply frame work, 9 Millimetre thick Plywood finished with1.00 Millimetre laminate for all exterior sides with approved shade and 12 mm glass fixed on teak wood beading as per detailed drawing & design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood - BWR IS303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge.) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 3 LOW HEIGHT PARTITION - Providing & fixing 75 Millimetre thick Partition using 50 Millimetre thick Plywood having 12 Millimetre thick Plywood for both sides. Partition Should for Frame having Finished with 1.00 Millimetre thick laminate, 12.00 Millimetre thick Clear glass with necessary fixtures to be provided as directed etc. complete. As per detailed drawing and design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design.Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 4 Storage - Providing & fixing Stoarage USING 19 Millimeter thick BWR plywood IS 303 standerds empowerd with antitermite anti fungus chemical plywood for structure 6 mm Plywood for back. 25 mm thick block board full pinn BWP door should finish with handles 12 stainless stell & mortice locking arrangement . All exterior surfaces should finished with 1.00 Millimeter laminate and internally finished with mm thk. while laminate storage should have handles locking arrangement etc. complete as per detaile drawing and design .(Depth of Storage 0.45 meter).with all necessary fixture and fastenings etc complete.( Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 5 Entrance Door - Providing & Fixing Sandwiched doors for cabin using 19+12 thick ply for both sides should finished with 1.00 mm thick laminate. All exterior faces should coverd with T.W. beading doors should have 6 mm thick clear glass S.S. Handle, Lock, Stoppers and Hydraulic door closer etc.complete. SS hinges , SS handles , TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS 303 Standards empowerd with antitermite anti fungus chemical. (Before execution sample should be get approved from engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 6 Prownling and Fixing Service Counter made up by 19mm thick Plywood structure, lack and tops. All plywood surfaces finished with 1.00 mm thick Lantinate, Counter should Square have two tops, drawers, storage and keyboard thaye having necessary fittings like hinges, handdles and locking arrangement etc. complete as directed SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 7 Providing & fixing Officer table of size 1.5*0.75*0.75 meter using 25 mm thick for top & 19 mm for sides. externally finished with 1.00 mm thick laminate and internaly finished with 2.00 mm thk. white laminate Table should have side table of size 1.40*0.40 meter with drawers and doors, locking arrangement, footrest, keyboard tray of size 485*180mm & cable manger etc. complete. As per detailed drawing and design. Plywood-MR Grade 100% BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 8 Staff / Clerk Table - Providing & fixing Officer table of size 1.37*0.60*0.75 meter using 25 mm thick for top & 19 mm for sides. externally finished with 1.00 mm thick laminate and internaly finished with 2mm thk. white laminate Table should have side table of size1.40*0.40 meter with drawers and doors, locking arrangement, footrest, keyboard tray of size475 X 180mm & cable manger etc. complete. As per detailed drawing and design. Plywood-MR Grade 100 % BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 9 Providing & fixing Executive table of size 1.80*0.90*0.75 meter using19+19 Millimetre thick Plywood for top & 19+12 Millimetre for sides. Externally finished with Imm thk laminate & internally with Imm thk white laminate respectively. Table should have side table of size 1.50*0.40 meter with drawers and doors, locking arrangement, footrest. keyboard tray of size 485*180 Millimetre & cable manger ete, complete. As per detailed drawing and design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood - BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 10 MS Rack -Providing and fixing mild rack of TCPC satara make Cat no Msrk -1 or equivalent make having overall size 1.80 meter x 0.90 meter x0.40 meter. Including five rack and four side anfle of approved size as per detailed drawing and design including all necessary etc. complete and as directed by engineer incharge. Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 11 Providing and arrangemnt of high back chair, synchronized mechanism with multiple locking, adjustable armrest, gaslift for seat height adjustment, standard 5-prong P/Nylon base with leatherite upholstery. 12 Providing and arrangemnt of mid back chair, normal synchronized mechanism, fixed armrest, gaslift for seat height adjustment, standard 5-prong nylon base with leather upholstery. 13 Providing and arrangemnt of mid back chair, ECO CTS mechanism, fixed armrest, gaslift for seat height adjustment, standard 5-prong P/Nylon base with fabric upholstery. 14 Providing and fixing 3 seater public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 15 Providing and fixing sofa set 3+1+1 brown and cream leather Dimensions - length 182.5 centimetre, breadth 100 centimetre, height 100 centimetre, weight - 66 kg. Seating capacity - five seat. 16 Providing and fixing rollar blinds of approved make and shade of 38 milimetre round aluminium channel with blackout fabric and telting with chain (ball) system with all necessary fixtures and fitting, excetra complete. 17 Providing and fixing false ceiling with eco-friendly light weight calcium silicate tiles of spintone surface texture “aerolite” make or equivalent of size 595 milimetre X 595 milimetre having 15 milimetre thick densified micro look edge and 100 percent humidity resistance incombustible as per BS 46 part IV and thermal conductivity 0.043 w/m0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600 milimetre X 600 milimetre made from hot dipped galvanised iron steel sections ion silhouette profile, rotary stitched double webbed white with 6 milimetre reveal profile (white/black), wherein, main “T” runner of size 42 milimetre X 14 milimetre between main tee 600 milimetre center to center and secondary cross “T” of size 33 milimetre X 14 milimetre X 0.43 milimetre thick of length 600 milimetre long spaced inter-locked at middle of the first crossed “T” in each panel to form grid of 1200 milimetre X 600 milimetre resting on periphery wall Profile wall section 19 milimetre (7+7) X 19 milimetre X 0.40 milimetre thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, smoke detectors excetra, wherever required. Main “T” runners suspended from ceiling with using galvanised iron soffit cleats of size 25 milimetre X 35 milimetre X 1.6 milimetre of required length fixed to the ceiling with 6 milimetre diameter and 50 milimetre long dash fastener, 4 milimetre diameter galvanised iron adjustable rods with powder-coated / good quality galvanised iron level adjustment clips of 35 milimetre X 35 milimetre X 0.8 milimetre spaced at 1200 milimetre center to center along main “T” all complete at all heights as per the specifications, drawings and as per the directions of Engineer In-charge. (For Ground Floor) 18 Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed / fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 X 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts excetra all complete. (For Ground Floor) 19 Providing & fixing Shutters for existing in-built storage made in 19+19 Millimetre ply frame work,19+6Millimetre thick Plywood finished with 1.00 Millimetre laminate for all exterior sides with approved shade using necessary hardware teak wood lipping and etc. as per detailed drawing & design.SS hinges, SS handles, TW lipping etc. complete. As per detailed drawing and design. Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should be get approved from Engineer In charge) Rate Approved by S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 20 Providing & fixing Computer table of size1.20*0.60* meter using 25 mm ply for top & 19 mm thick ply for sides. Internally and externally finished with ?.?? mm thick laminate & internally with 1mm white laminate respectively. Table should have ebco keyboard of size 485*180 mm including necessary hardware, teak wood Lipping etc. complete. per detailed drawing and design.SS hinges, SS handles, lipping etc. coniplete. As per detailed drawing and design. Plywood BWR IS 303 standards empowered with antitermite anti fungus chemical. (Before execution sample should get approved from Engineer In charge) Rate Approved S.E.PW Circle Kolhapur Wide Latter No. 26/2024 Dt.03/01/2025 21 Detearmination of resistance to dry heat, determination moisture content, determination of density,thickness plywood 22 Test for glue adhesion
Contract Date: May 19, 2026 Contract Value : 1.79 Crore
Government Departments No of Bidders 2
Maharashtra View Result →
34.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
35.
Communications and Information Technology  #11104527 AOC
Tender For Auction of identified items from the premises of Durgapur IT Park-- 1 Damaged & dismantled Aluminium Door Frame (Aluminium scrap) 2 Broken Black Stone Slab (cermet scrap) 3 Rusted Corrugated Sheet (GI scrap) 4 Dismantled Iron Grill (MS scrap) 5 Damaged Light Post MCB DB Box (MS scrap) 6 Damaged Fire Pipe Hanging Rod (MS scrap) 7 Damaged False Ceiling Gypsum Board (cermet scrap) 8 Damaged & discarded Light Post (GI scrap) 9 Damaged Revolving Chair (plastic scrap) 10 Damaged & dismantled A.C. Ducts (GI scrap) 11 Damaged & dismantled False Ceiling Grid Materials (GI scrap) 12 Discarded & useless 4 Core 16 SQ MM Cable(Aluminium scrap) 13 Discarded & useless 4 Core 25 SQ MM Cable(Aluminium scrap) 14 Discarded & useless 4 Core 300 SQ MM Cable (Aluminium scrap) 15 Discarded & useless A.C. Foam Tube (plastic scrap) 16 Broken windows Glass (glass scrap) 17 Damaged & discarded A.C. Ducts (GI scrap) 18 Discarded & useless 4 Core 16 SQ MM Cable (Aluminium scrap) 19 Damaged & discarded Grill Gate (MS scrap) 20 Damaged & discarded Corrugated Sheet (GI scrap) 21 Rusted & discarded G.I.Pipe (GI scrap) 22 Damaged & discardedFloor springs (MS scrap) 23 Damaged & discarded Key Board Tray (Wood scrap) 24 Damaged & discarded C.P.U. Rack (Aluminium scrap) 25 Damaged & discarded Aluminium Door (Aluminium scrap) 26 Damaged & discarded Door Frame (Wood scrap) 27 Damaged & discarded Revolving Chair (plastic scrap) 28 Damaged & discarded Iron Angle For Cable Tray (MS scrap) 29 Damaged & discarded Flush Door (wood scrap) 30 Damaged & discarded False Ceiling Gypsum Board (cermet scrap) 31 Discarded & useless 12V 180 AH. Battery (scrap of primary cells) 32 Discarded & useless 12 Volt 7 Ah Battery(scrap of primary cells) 33 Rusted & discared Metal Fire Hose Box (MS scrap) 34 Discarded & useless DB Box diff sizes (MS scrap) 35 Discarded & useless Light Set 2X2 (Plastics scrap) 36 Discarded & useless Spot Light (Plastics scrap) 37 Discarded & useless D.G. set Lube Oil (waste oil) 38 Discarded & useless D.G. Set Air Pass Filter For Canopy (MS scrap) 39 Discarded & useless Ductable ACIndoor Unit (GI scrap) 40 Discarded & useless Ductable ACIndoor Unit (GI scrap) 41 Manual garden roller (MS scrap) 42 Damaged & dismantled A.C. Ducts (GI scrap)
Contract Date: May 17, 2026 Contract Value : 1.65 Lakh
Government Departments No of Bidders 5
West Bengal View Result →
36.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
37.
Defence #11095458 AOC
Tender For Special Repair To Certain Technical Bldg At Af Stn Bkt; 1 Demolition of cement concrete of any description and in any position and complete removal of demolished material exc. 500 m but not exceeding 1.5km to outside Defence land complete all as specified and as directed. 2 M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in floor and finished rough to receive the floor tiles etc complete all as specified anddirected. 3 Dismantling floor, hearth or wall tiling including cement mortar bedding, terrazo dado from wall surface(but not backing), removing serviceable tiles to store and rubbish off the premises. Complete all as specied and directed. 4 M&L for Non - skid DigitalCeramicjoint lesscoloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match the surface over and including15 mm thick screed bed in CM (1:4). Complete all as specied and directed.(Make-: Kajaria Tiles/HR Johnson/Somany) 5 M&L for glazed ceramic colouredDigital tiles in vertical surface300x600x7mm thick, set and jointed in neat cement slurry and pointed white or colored cement to match the surface over and including 10 mm thick CM (1:4) Complete all as specied and directed. (Make-: Kajaria Tiles/HR Johnson/Somany) 6 M&L for Vitrified digital double charge light coloured tiles 8-9 mm thick ( square or rectangular) polished, area of each tiles 600 mm X 600 mm as in floors etc.and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM 1:4Complete all as specied and directed. (Make -Kajaria/ Somany/ HR Johnson) 7 Ditto all as per item No 06 above but on wall surfaces over and including 10mm thick rending in CM (1:4) complete all as specified and directed. 8 M&L for mirror rubbing & polishing of kota stone, where ever required to give glossy finish and half nose moulding (bull nosing) etc,complete all as specified and dirceted. 9 Demolition ofreinforced cement concrete of any description at groundfloor and complete removal of demolished material exc. 500 m and upto total distance of 1.5km to outside MoD Land complete all as specified anddirected. 10 Use and waste for formwork to sides and soffits of floor or room beams, beams haunchings, girders, bressummers, lintels, girders, bressummers, lintels, cantilevers, shelves includings supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete complete all as specied and directed. 11 M&L for Machine cut Cudappah stone slab size 25-30mm thick over cement screed base,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing Complete all as specied and directed. 12 M&L for Jet south black granite slab work 18 to 20mm thick (table rubbed and polished) in cooking platforms and jointing in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types over and including 15mm thick screed bed in CM (1:6)set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces and half nose moulding (bull nosing) etc, complete all as specified and directed. 13 M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified directed. 14 Demolition of brick work built in cement mortar including all quoin, arches pillars but excluding ashlar facing dressed stone work and precast concrete article complete all specified anddirected. 15 M&L for Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and as directed. 16 M&L for Brick work with subclass B bricks, old size bricks, straight or curved onplan exceeding 6 metre mean radius built in cement mortar (1:6)but except bricks Complete all as specied and directed. 17 M&L for Brick work with fly ash old size bricks, straight or curved to any radius in half brick thick walls, built in CM (1:4) complete all as specified and as directed. . 18 Taking down cement plaster on brick or concrete surfaces walls/chajja/roof,facia at any heigh including racking out joints hacking for key scrubbing down with water etc and M&L for rendering 15 mm thick in cement mortar (1:4) on fair face of brick work of walls mixed with water proofing compound (ISI Marked) @ 2% by weight of cement or as per manufacturers instructions finished even & smooth without using extra cement complete all as specified including mouldings chamfers splay srounded or coved angles. Beards grooves and rebate upto 10 cms in width or 15 cms in girth. Note: Supply only water proofing compound shall be measured and paid for seperately complete all as specified and directed. 19 M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistace as per IS 15489:2004. Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @1.43 ltr/ 10 sqm over and including one coat of wall care putty 1 mm thick over priming coat of exterior primer applied @ 0.90 ltr/ 10 sqm over new/oldsurfaces complete all as specified and directed. Note: Putty,Primer and Emulsion to be carried out through air less spray machine complete all as specified and directed.(Mechanical Means) (Make:- Asian Paint Apex ultima/Berger weather coat long life 10/Nerolac Excel everlast 12) 20 M&L for complete removal of existing treatment on RCC/stone/concrete/brick walls including preparation of old surface by affixing wall care putty rubbing to smooth finishing and and applying two coat of 100% premium acrylic emulsion Comouflaging pattern having VOC less than 50gm/Ltr and UV resitance as per IS 15489-2004 alkali and fungal resistance, dirt resitance exterior paint of required shade (company depot tinted)with silicon additives @1.43 ltr/10 sqm over and including priming coat of exterior primer applied @09.ltr /10sqm over new prepare surface and height upto 9 meter complete all as specified and directed by and directed. Note : Primer and emulsion to be carried out through airless spray machine (Mechanical means)(Make Asian paint apex ultima/Berger weather coat long life 10/Nerolac excel everlast 12). 21 Supply only Integral water proofing compound complete all as specified and directed. 22 Taking down cement plaster on brick/stone walls/concrete in Roof/Chajja etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all specified and as directed. (Note :- Work will be carried out up to 3rd storey with necessary scaffolding). 23 M&L for rendering 15 mm thick on fair faces of brick or concrete surface walls, in cement mortar (1:6) rendering is to be finished even and smooth without using extra cement. 24 M&L for preparation of old distempered surfaces of wall by washing rubbing down and stopping of old distempered surface of wall including cornices etc and 1mm thick wall care putty as required for levelling and applying two coat of oil bound distemper (Oil emulsion any tint) on wall complete all as specified and directed.Note: Putty,Primer and Emulsion to be carried out through air less spray machine (Mechanical Means) (Make :- Asian Paint Tractor uno/Nerolac Beauty Acrylic/ Berger easy clean) 25 M&L for rendering 10 mm thick on fair faces of brick or concrete surfaceceilings, in cement mortar (1:3) finished even and smooth without using extra cement and applying two coat of white wash on new plastered surface of ceiling after preparation of surfaces complete all as specified and as directed. 26 M&L for preparation of old decorated surfaces by brooming down or steel wire brushing,scrappingdown smoke soot mould, moss and treading oil and greasy spots from plasterd or unplasterd surfaces of ceiling including cornices,pilasters etc and applying one coat of white wash complete all as specified and directed. 27 Taking down chowkats or frames areanot exceeding 1.50 Sqm(w/o taking off shutters from frames) and removing from site, including cutting holes for taking out existing hold fasts and making good in cement mortar (1:3) or PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate, complete all as specified and directed. (Note – The quoted rate shall be deemed toinclude for fixing of hold fast in the same opening irrespective of position of hold fasts and no separate item for making good of hold fasts shall be paid). 28 Taking down chowkats or frames area exceeding 1.50 Sqm andnot exceeding 4.00 Sqm (w/o taking off shutters from frames) and removing from site, including cutting holes for taking out existing hold fasts and making good in cement mortar (1:3) or PCC (1:2:4) type B0 ussing 12.5 mm graded stone aggregate, complete all as specified and as directed. (Note – The qouted rate shall be deemed toinclude for fixing of hold fast in the same opening irrespective of position of hold fasts and no separate item for making good of hold fasts shall be paid). 29 S&F factory made UPVC door frame white colour extrudedwith wall thickness of 2.3mm (+ -0.2mm). Corrner of door frame jointed with galvanised brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frame reinforcement by galvanised MS tube of size 19mm x19mm and 1mm (+- 0.10mm) wall thickness and 3 Nos stainless steel hines by the manufacture and as per directed.(Make :- Rajshree plastiwood/Kaka Industries/century plywood). 30 S&F factory made uPVC white colour casement (Openable) Door made of extruded profile with wall thickness of2.3 mm(+ 0.2 mm). Window profile with hollow section with mitlti chamber, frame (60 mm x 58 mm), sash (60 mm x 78 mm). T profile (onevertical length in between two shutters) (60 mm x 74 mm). Glazing bead (35 mm x 20 mm) will be mitered cutand fusion welded at all corners, including drilling of holes for fixinghardware and drainage of water etc. Making arrangement for fixing ofhardware. EPDM gasket 1.2 + 0.2 mm thick galvanized steel Frame (28 mm x 21.5 mm), sash (31 mm x 27 mm), T profile (27 mm x 17 mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners.(Hardware : casement doorhandle made of zinc alloyed (white powder coated), Corner striker, Secondary Strikers, Cylinder, Door transmission gear made of mild steel with multi point locking system with strikes 3D Hinges of zincalloyed (white powder coated) and 5 mm thick glazing with selected quality glass.}( Note : The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose).(Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 31 S&F factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (112mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. locking arrengment as directed, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories area not exceeding 2.00 sqm each complete all as specified and directed. (Make:- Compreshive/Prominance/Fenesta. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)(Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 32 S&F factory made UPVC white colour fixed vent areaexceeding 1.00 sqmnot exc. 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass cmplete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.) :-(Make :- Rajshree Plastiwood/Kaka Industries/century plywood) 33 S&F for sheet glass 5.50 mm thick, toughned glass, fixed in UPVC windiw including all fitting and fixturres complete all as specified and directed. Make:- Modigaend/ Saint Bobin/ Asahi India Glass. 34 S&F Factory made single extruded(Wood Polymer Composite) solid door/ window/ Ceosetory windows & otherFrames/ Chowkhat with double ribet of size 125mm x65 mmcomprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calciumcarbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threadedstar headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spreadof flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant with and encluding MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note:- For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(Make :- Rajshree Plastiwood/Kaka Industries/century plywood) 35 S&F factory madesingle extruded WPC (Wood Polymer Composite) solid decorative type 10mm deep CNCmoulding design with 0.12 micron laminated both sides shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame ofClass A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved designpasted with hot melt adhesive on both faces of shutter and fixing with and including stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and direction. (Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 36 S&F Factory made single extruded WPC(Wood Polymer Composite) solid door/ window/ Ceosetory windows & otherFrames/ Chowkhat of size 45X70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calciumcarbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threadedstar headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spreadof flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with and including MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction. Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 37 S&F factorymade single extruded WPC (Wood Polymer Composite) solid decorative type 10mm deep CnCmoulding design with 0.12 micron laminated both sides shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame ofClass A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved designpasted with hot melt adhesive on both faces of shutter and fixing with and including stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws. Complete all as specified and directed. (Make :- Rajshree Plastiwood/Kaka Industries/century plywood) 38 S&F for Aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specifed and directed. 39 S&F 300 mm aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts complete all as specified and directed. 40 S&F Aluminium handles cast type anodised of 150mm complete all as spcecified and directed. 41 S&F butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed 100 mm long, type B-21 complete all as specified and directed. 42 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 43 S&F for mild steel framed work such as grills, gratings etc with ends of bars, M S pipe shouldered and or reiverted or forged into spikes, framed guard bars and similar work conferming to Fe- 290-0 Gde-E-165 complete all as specified and directed. 44 S & F for stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed withtinned tacks or galvanised wire staples complete all as specified and directed. 45 M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat ofzink chromeprimer including necessaryrubbing with sand paper or grinded byhand grinder to achieve smooth and even surface complete all as specified and directed. (Make :- Asian Apcolite Premium Gloss Enamel/Nerolac Synthetic High glass Enamel /Berger HI-Glass luxol ) 46 M&L for applying one coat of synthetic enamel paint to old painted steel surfaces of any description having width/girth exceeding 10 cmcomplete all as specifie including preparation and rubbing withsand paperto make surface even and smooth complete all as specified and as directed.(Make :- Asian Apcolite Premium Gloss Enamel/Nerolac Synthetic High glass Enamel /Berger HI-Glass luxol). 47 S&F in rplacement 20 mm nominal outer diaChlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply, including all Plain CPVC SDR 11 fittings & brass threaded fittings on walls/ceiling or laying in floors,including fixing the pipe with clamps. This includes jointing of pipes & fittings with one step CPVC solvent cement, complete all as specifed and directed. 48 S&F in replacement GI tubes medium grade galvanised, 20 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. 49 Dismantling water tanks and removing to store of water storage tanks (Cap. 500 ltr to 1000 ltr ) complete all as specified and directed. 50 Supply and fixingRotational moulded polyethylene water storage tanks of 500 litres capacity (white colour with threaded lid cover,minimum tripled layer , weight not less than 18 Kg), hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, highcomplete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specifed and directed. 51 S&F in rotational moulded polyethylene water storage tanks of 1000 litres capacity (White colour with threaded lid cover, cylindrical vertical with closed topminimum tripled layer , weight not less than 33 Kg), white, hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, highcomplete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specified and dircted. 52 S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore pipe including making connections complete all as as specified and directed (Minimum weight 20mm-210 gms). (Make -: Prayag /JK Rubber Industries/Supreme Industries/ Prince/ JAL). 53 S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, Bore dia of 20mm complete all as specified and as directed.(Make :- Zoloto/Leader/Bajaj) 54 M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in floor/ plinth protection laid in alternate bays finished even and smooth without using extra cement including joints filling by using mastic filling comprising one part of bitumen 85/25 mixed with three parts of coarse sand by weight complete all as specifed and directed. 55 S&F in repair PVC valveless,syphonic action type, flushing cistern, low level,white with inlet, ball valve, float and handle including brackets, PVC 32 mm L bend of capacity 10.0 litres and making good to dismantled/damaged floor/surfaces, fixing in repair, complete all as specified and as directed.(Make:- Jaquar/kohler/Grohe/ JAL). 56 S&F Vitreous china ware pedestal type water closet white, with P or S trap including self closing seat cover, closed pattern with flat bottom, 100 mm bore pipe & bedding in PCC (1:2:4) B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make:- Jaquar/kohler/Grohe) 57 S&F in repair CP Bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified and directed.(Make:- Jaquar/kohler/Grohe). 58 S&F in repair CP Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.(Make:- Jaquar/kohler/Grohe) 59 S&Fin repair angle valve with wall flange , cast copper alloy, chromium plated fancy type screwedfor 15 mm iron pipe, complete all as specified and directed. (Make:- Jaquar/kohler/Grohe) 60 S&F in repair PVC connection 15 mm x 450 mm including PTMT check nut at both ends screwed for iron pipe of 15 mm bore. complete all as specified and directed. 61 S&F in repairVitreous China, wash basin white, flat back , size 550mmx400 including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32 mm dia, waste coupling of waste couplingcomplete all as specified and as directed.(Make:- Jaquar/kohler/Grohe) 62 S&F in repairstainless steel Shop dish with PU foam complete all as specified and directed. (Make:- Cera/Prayag/Jaquar/kerovit) 63 S&F in repair for bevelled edge mirror of size (600mm x 450mm), selected quality glass approved size , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with SS screws and cup washers complete all as specified and directed. 64 S&F in chromium plated brass Urinal auto closing type with built in control box & wall flange etc. complete all as specified and directed. (Make:- Cera/Prayag/Jaquar/kerovit ) 65 S&F in vitreous china half stall urinal with grating and union complete set with 40 mm dia GI light grade waste pipe including. brackets etc complete all as specified and directed. (Make:- Cera/Prayag/Jaquar/kerovit ) 66 S&F in urinal spreader chromium plated for fixing with 15 mm bore pipe etc. complete all as specified and directed.(Make:- Cera/Prayag/Jaquar/kerovit) 67 M&L for cutting chases, pinning in , making good to facings where required and pointing in cement mortar1:3 to ends or edges of landings,steps,cills,sunshades,shelves,lintels etc,and cutting chases for concealed water tubing or concealed conduit wiring,etc,and making good,cutting n.exc 10cm girth in brick walls complete all as specified and as directed. 68 Dismantling PVC/Cement/CI pipes 50 to 110 mm diaincluding allfittings like bend,branch pieces, connectors, heel rest bend etc and removing from site complete all as specifed and directed. 69 S&F in UPVC (SWR) type B pipes 110 mm bore single socketed, in any length with rubber ringjoints laid in trenches orin floors complete all as specified anddirected. 70 S&F UPVC (SWR) type B pipes 110 mm bore single socketed, in any length with rubber ringjoints fixedto walls including stack clamp of GI flat 50mm wide 5mm thick and 16mm dia fixed to wall with nail at spacing of 1m center to center ,complete all as specified and directed. 71 S&F in UPVC (SWR)type B pipes 75 mm bore single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and directed. 72 Supply and fixing, UPVC (SWR) , bends for75 mm bore , complete all as specified and as directed. 73 S&F in UPVC(SWR) , bendsfor110 mm borecomplete all as specified and directed . 74 S&F in repair UPVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. 75 M&L for high performance hybrid plyurea elastomeric waterproofing coating cold applied of spray/brush applied,samrtcare ulton liquid membrance at 1.5kg/sqm with an elongation of 600% and tensile strength of 12.6 N/sqmm as per ASTM D2370,crack bridging ability of 3.5mm as per ASTM C1305,shore a hardness of min 75 as per ASTM D2240.The system smartcare includes final base preparation as per site requirement,epoxy primer application and applying smart care Ultron or approved equivalent in two coats at a coverage of 1kg/sqm etc complete as per manufacturer specification including complete removal of old waterproofing system and repairing and cleaning the existing surface complete all as specified and directed.Make :- Asian Paints/ STP/ Berger/ Sika/ Pidilite. 76 M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope commplete all as specified and directed. 77 M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggreate as in benching , haunching kerb etc rounded or chamfered on edges including necessary formwork complete all as specified and directed 78 M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in sub base of 100 mm thickness complete all as specifed and directed. 79 M&L for precast factory made Chequered tiles of size 300mm x 300mm glazed topmade in whitecement and pigment base of thickness not less than 19mm in differentcolourand pattern(compressive strength not less than 250 kg/sqcm) set and jointed in neat cement slurry cover and including 20mm thick screed bed in CM (1:4)complete all as specifed and directed. 80 M&L for plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregatein lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and as in benchingand similar work including necessary form work complete all as specifed and directed. 81 S&F Anodised aluminium powder coated snap grid frame workexposed suspended system grid size 595mm X 595 mm comprising of GI powder coated main T -3600/crossT-600/size 25X35X0.7mm, wall angle 25X0.7mm & soffit cleat 37X25X1.80mm thick including dismantling of wll and ceiling boards of any thickness with cover fillets complete all as specifed and directed. (Make -: Everest / Armstrong/Techno Ceiling Product) 82 S&F hanger of4mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40mm x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed (Make -: Everest) 83 S&F Non asbestos fibre cement building boards 4 mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specifed and directed.(Make -: Everest / Armstrong/Techno Ceiling Product) 84 Taking down copper/aluminium point wiring for (light, fan, socket or power) complete including unserviceable fittings such as switches, ceiling rose, holders, sockets,light fittingsetc. and making good the disturbed surfaces on wall/floor etc complete all as specified and directed.Note- (i) Dismantled serviceable light fitting shoud be kept in safe custodyfor reuse.(ii) Refixing of serviceable fitting shall be paid seperately under relevant items- 85 Refixing of serviceable light fittings upto 22 watt obtained form item No 84 above including connecting up with 3 core flexible cable copper conductor of suitable size from ceiling rose complete all as specified and directed. 86 Taking down fans/meter/Geyser/Exhaust fan from existing position and removing the same and depositedto MES store and will installed after completion of work. complete all as specified and directed. 87 Taking down old and unserviceable sub main wiring any size/type /core incl earth wire complete with batten conduit etc complete all as specifed and directed. 88 Taking down old and unsv sheet metal enclousure ,switch fuse unit,distribution board any type/way/capacity including fuses mcbs ,insulator rccbs etc copmlete after removing all connectionand making good the disturbed surface complete all as specifed and directed. 89 Refixing of serviceable MCBs 5-32 Amp rating 240 Volt 10 KA including connection and commissioning including providing lugs and thimbles complete all as specifed and directed. 90 M & L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt gradein non metallic rigid PVC concelled conduit medium grade 25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of module metal flush boxes and including modular front coverplate & back plate for mounting modular type switches /socket/fan/ regulator etcincluding provision of one single corePVC insulated and unsheathed multi stranded copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dollyswitch board complete for following-Make of Cable- Plaza/Finolex/Havells/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex.One light/fan point controlled by one switch SP 5 Amps ,240 V 91 One 3 pin 5 amps switch socket outlet point on independent board complete all as specifed and directed. 92 Ditto all as per item No 90 above but for One 3 pin 5 amps socket point on same board complete all as specifed and directed. 93 Ditto all as per the item No 90 herein before but with 2.5 sqmm conductor for5 pin 15 Amps switch socket outlet. complete all as specifed and directed. 94 S&F switch modular type 1 module single pole, one way 5 Amps complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB 95 S&F switch modular type 1 module single pole, one way 15 Amps. Complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB 96 S&Fsocket outlet 2 in 1, 5 pin, 15Amps modular type 2 module complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB 97 S&F socket outlet 5Amps modular type 2 module complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB. 98 M&L ceiling rose,PVC/polycarbonate, isolated body complete all as specifed and directed. 99 S&F Submain wiring with two single core PVCinsulated FRLS multistrand copper conductor cable of size 10Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCcondute not less than 25mm size ISI marked ivory colour (Pressfit or similar brand ) with allfittings / accessories and 10Sq mm FRLS multistrand copper conductorcable as continuous earth wire complete. Not:- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the quoted unit rate for this items.)Make- Polycab/Havells/RR kables/plaza. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex 100 S&F Submain wiring with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 04 Sq mmdrawn into and including non metallic medium duty rigid concealedPVCcondute not less than 25mm size ISI markedwith allfittings / accessories and 04 Sq mm FRLS-H multistrand copper conductorcable as continuous earth wire complete. Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the quoted unit rate for this items.)Make- Polycab/Havells/RR kables/plaza. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex 101 S&Fsheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar VTPN,4 way vertical type, with provision of MCCB incommer, AC, 415 Voltcomplete all as specified & directed.Make :- Havells / Legrand /Seimens/L&T / C&S. 102 S&F Sheet metal enclosure 12 way double door distribution board when MCB to be used SPN 240 volt sheet complete all as specified and directed.Make :- Havells / Legrand /SeimensL&T/ C&S. 103 S&F MCCB 4 pole 100 / 125 Amp 415 volts 50 HZ25 KA breakingcapacity complete all as directed.Make :- Havells / Legrand /Seimens L&T/ C&S. 104 S&FMCB SPN 40 to 63 Amps 240 volt,50 hz,10 KA breaking capacity :C curved type complete all as specified and directed. Make :- Havells / Legrand /Seimens L&T/ C&S. 105 S&F MCBsingle pole, 6 to 32Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :- Havells / Legrand /SeimensL&T/ C&S. 106 S&F socket outlet 5 pin 20 amp modular type 2 module with suitable size of module metal flux boxes and including modular front cover plate and back plate for mounting modular type switch & socket with one single poleone module MCB of 20 amp including electrical connection all as specified and directed.Make-Havells/ABB/Goldmedal L&T/ C&S. 107 S&F in LED light fittings 1x18/20 watt ,220 volt AC decorative box type with driver holder including 18 watt LED tube light connecting up with 3 core flexible cable copper conductor of suitable size from ceiling rose complete all as specified and directed .Make - Phillips/Havells/Bajaj L&T. 108 S&Fin square recessed / surface/suspendedmounting LED ceiling light with extruded aluminium housing and milky diffuser of 36 W 2X 2panel complete with LED driver 240 V ,50 Hz,3600 lumen 6500 k complete all as specified & approved by EIC Make - Phillips/Havells/Bajaj/ L&T. 109 S&F in LED security light 60 watt complete with security light bracket (complete with two set of clamp ,nut and bolt) made out of 40 mm medium grade GI pipebend to shape and with fixing arrangements duly welded (length of pipe should not be less than 1.2 mtrs) and making conection with using 1.5 sqmm PVC insulated multistranded copper conductor two single core cable complete all as specified and directed.Make - Phillips/Havells/Bajaj/ L&T. 110 Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the type and sizes50 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.Make : Plaza/ Finolex / Polycab /RR cable/ Havells 111 Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed. 112 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soilcomplete all as specified and directed. 113 Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. 114 M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed. (Note:- Punned thickness only shall be measured & Paid). 115 M&L for precast cable cover class LV type 1 flat size 250mm x 150mm x 40mm, laidflat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specifed and directed. 116 M&L for Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed by Engr-in-Charge. Note : GI pipe shall be measured and paid separately under relevent items given here-in-after. 117 M&L for 80mm dia steel tubing, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified and directed.Make -Jindal/Tata/Finolex /Prakash Surya. 118 S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter volt 230 V 50 Hz RPM 1200 copper winding of sweep 250 mm. complete all as directed and specified and directed.Make:- Havells/Philips/crompton/Bajaj/ L&T. 119 Supply installation and testing of wall mountedAir circulator 400 mm sweep with high speed and aerodynamically designed Acrylonitrile Butadienealuminium blades / body, jerk free and smooth oscillation and inbuilt regulator system chord complete all as specified and directed. Make:- Havells/Philips/crompton/Bajaj/L&T. 120 M&L forflame proof pointwiringwith two single core FRLS-H PVC insulated& PVC unsheathed multi stranded copper conductor cable of size 1.5Sqmm1100 voltsgradein and includingstove enamelled steel conduit of size20 to 25 mmwith all accessories and one single core PVC insulated & PVC sheathed multistranded FRLS-H copper cable of size 1.5 Sqmm 1100 Voltsgradeas earthcontinuityconductorconnectedto commonearth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with 1:4 cement morter all as specified for one light / fan point controlled by one 5 Amps flameproofswitch one way complete all as specifed and directed. 121 Supply and fixing LED Light Fitting 2x20 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable sizecomplete all as specified and directed. Make:- Philips/ Bajaj/ Crompton/ Bajaj/ L&T. 122 S&F flame proof metallic body exhaust fan single phase 230 Volt 50 Hz 300 mm 1440 RPM with louvers and shutter including civil work i.e making of holes and complete with all fixing accessories all as specified and directed by E-in-Charge . Make :- Shyam / Bajaj/ Crompton/ Bajaj/ L&T. 123 M&L for switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed.Make- Legrand/ Scimens/Havells/ L&T/ C&S.
Contract Date: Jan 21, 2026 Contract Value : 27.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
Uttar Pradesh View Result →
38.
Defence #11095455 AOC
Tender For Provision Of Stabilizer And Insolation Transformer On Hard (Rcc) Surface With Armored Cable At Tru At Af Stn Bkt; 1 Supply, Installation testing and commissioning of Isolation transformer, 3 Phase ,50HZ 125 KVA capacity ,copper wound, oil cooled, class A insulation, powder coated metallic body, designed for input voltage 415+ 5%,output voltage rate 415 + 5%,Ratio 1;1, DYN-11, Delta star indoor type, min IP 42 with first filling of transformer oil as per IS 335 upto level, efficiency more than 95%. separate neutral bush for neutral to earth less than IV, with all standard accessories including digital ammeter , voltmeter , short cicuit protection , unbalance voltage protection, MCCB/MCB of suitable rating in incoming with by pass arrangementdigital type temperatures meter, cooling radiator, lifting hook earthing terminals – 2 Nos with MCCB for overload / short circuit protection bushing complete all as specified and directed . The transformer shall be confirming to IS: 1180: 2014 and shall comprise of the following:- (a) Rating and diagram plate. (b) Two earthing terminals in two side. (c) Lifting lugs .(d) Off circuit link board. (e) Base channel with Bi- directional Rollers. (f) Danger board (g) 100 mm dial type thermometer. (h) Cable entry boxes etc complete as reqd. (i) Plinth of PCC (1:3:6) type C-1 using 20mm graded stone aggregate for placing and supporting of Isolation transformer complete all as specified and directed.Make:- Vinetec/ Servostar/ Volina/ Indian Transformer and Electrical (Note:- E-N voltage should not be more than 2 Volts). 2 Supply Installation testing and commissioning ofServo controlled voltage stabilizer of capacity 160 KVA Confirming to BIS 9815: Part1:1994 reaffirmed 2009) Three Phase, 50 Hz, Naturally Oil cooled, indoor, for unbalanced load, Copper wound, metallic body with lifting hooks, digital display type, relay free smooth and silent operation including 1st filling of transformer oil up to level having following specification:-(a) Input voltage 300V-480V, (b) Output voltage stabilized at any designed/ desired voltage 415(+/-)1%(c ) No distortion in wave form.(d) Respond time not to exceed 20 mili seconds (e) Sensitivity(+/-) 1% (f) 8 Volt/second correction . (g) Efficiency more than 98% (h) Type of load 3Phase, unbalanced type (i) Digital display Volt meter on incoming & outgoing to measure phase & line voltage with selector switch and Ammeter (j) Over load and short circuit protections , (k) High & Low voltage cut off(l) By pass arrangement in case of emergency and Single phase prevention complete all as specified and directed (m) MCCB of suitable rating at incoming and outgoing Make:- Vinetec/ Servostar/ Volina/ Indian/ Transformer and Electrical . 3 Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed. 4 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed . 5 Removing excavated materials (soil) not exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. 6 M & L for sand cushioning to underground cable with clean dry Ganga river sand complete all as specified and directed. Note:- Punned thickness only shall be measured & Paid. 7 M & L for precast cable cover class LV type 1 flat size 250mm x 150mm x40mm, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified & directed. 8 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 185 sqmm 3.5 core complete all as specified and directed. Make - Polycab/Plaza/Havells/Finolex/ RR Cable. 9 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 120 sqmm 3.5 core complete all as specified and directed .Make - Polycab/Plaza/Havells/Finolex/RR Cable. 10 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 95 sqmm 3.5 core complete all as specified and directed. Make - Polycab/Plaza/Havells/Finolex/ RR Cable. 11 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 50 sqmm 3.5 core complete all as specified and directed. Make - Polycab/Plaza/Havells/Finolex/ RR Cable. 12 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mmCRCA mild steel sheet with 50mm x 50mm x6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus barhaving current carrying capacity 1.5 times the rated current ratingfor phase & neutral, 4 strips 1.5 times of incoming rating on epoxy insulators, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and comprising of the following including necessary PCC in (1:2:4) type B1 using 20mm graded stone aggregate for platform of suitable size Comple all as specified and directed.Make- Power system & Control , Prestige , Sparsh Engineering , REW INCOMING MCCB 250 Amp 36 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No 13 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mmCRCA mild steel sheet with 50mmx 50mmx6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus barhaving current carrying capacity 1.5 times the rated current ratingfor phase & neutral, 4 strips 1.5 times of incoming rating on epoxy insulators, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size Comple all as specified and directed.Make- Power system & Control , Prestige , Sparsh Engineering , REW INCOMING MCCB 250 Amp 25 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No OUT GOING(i) MCCB 200 Amp 25 KA 4 PoleThermal - Magnetic Release-01 No. (ii) MCCB 125 Amp 16 KA 4 Pole Thermal - Magnetic Release-01 No.(iii) Digital Ammeter 0-100 Amp with built in selector switch - 01 No.(iv) Digital Voltmeter 0-500 Volt with built in selector switch - 01 No.(v) CT - 250/5 - 1 Set of three.(vi) Indicating lamp (RYB)-03 nos 14 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar Outdoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 3.15 mmCRCA mild steel sheet with 50x 50x6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus bar having current carrying capacity 1.5 times the rated current ratingrating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:- Make- Power system & Control , Prestige , Sparsh Engineering , REWINCOMING MCCB 200 Amp 25 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No OUT GOING(i) MCCB 200 Amp 25 KA 4 PoleThermal - Magnetic Release-02 No. (ii) MCCB 63 Amp 25 KA 4 Pole Thermal - Magnetic Release-01 No.(iii) Digital Ammeter 0-100 Amp with built in selector switch - 01 No.(iv) Digital Voltmeter 0-500 Volt with built in selector switch - 01 No.(v) CT - 200/5 - 1 Set of three.(vi) Indicating lamp (RYB)-03 nos 15 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar Outdoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 3.15 mmCRCA mild steel sheet with 50x 50x6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus bar having current carrying capacity 1.5 times the rated current ratingrating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size Comple all as specified and directed. Make- Power system & Control , Prestige , Sparsh Engineering , REWINCOMING MCCB 200 Amp 25 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No OUT GOING(i) MCCB 125 Amp 25 KA 4 PoleThermal - Magnetic Release-01 No. (ii) MCCB 63 Amp 25 KA 4 Pole Thermal - Magnetic Release-01 No.(iii) Digital Ammeter 0-100 Amp with built in selector switch - 01 No.(iv) Digital Voltmeter 0-500 Volt with built in selector switch - 01 No.(v) CT - 200/5 - 1 Set of three.(vi) Indicating lamp (RYB)-03 nos(vii) Tempra plug 125 A 3P+E - 01 No.(viii) Tempra plug 63 A 3P+E - 01 No. 16 Supply and fix or laying in trenches GItubing light grade of road crossing for cable protection etc,of the 80mm dia sizes including necessaryrequired complete all as specified and directed by Engr-in-charge.Make - Jindal / Prince Pipe/ Prakash Surya. 17 M& L for Earthing complete with copper plate earth plate electrode 60mm x 60mm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to copper strip of size 20mm x 3 mm as earth leadby means of bolts, nuts, check nuts and washers of brass or steel all as shown in electrical plate No 3 of MES Schedule Part-Iincluding and connecting to earthing testpoint block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 25 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC base 1:4:8 type using 40 mm agregrate of size 750x750x100 mm thick with precast RCCcover 40 mm thick in PCC (1:2:4) type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia welded with steel plate including painting with applying one coat of red oxide and two coat ofpainting with synthetic enameled paint of approved qualityincluding writting letters as specified including testing on completion complete all as specified and directed. 18 M& L for Earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) withtop edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete all as shown in electrical plate No 3 of MES Schedule Part-Iincluding and connecting to earthing testpoint block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 40 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) and (1:4:8) type D2 using 40 mm agregrate of size 750mm x 750mm x 100 mm thick with precast RCCcover 40 mm thick in PCC (1:2:4) type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat ofpainting with synthetic enameled paint of approved qualityincluding writing letters as specified including testing on completion complete all as specified and directed. 19 S&F Submain wiring with two single core PVCinsulated FRLS multistrand copper conductor cable of size 10Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCconduit not less than 25mm size ISI marked ivory colour (Pressfit or similar brand ) with allfittings / accessories and 10Sq mm FRLS multistrand copper conductorcable as continuous earth wire complete all as specified and directed.Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesare deemed to be included in the unit rate quoted for this items.) 20 S&F Submain wiring with two single core PVCinsulated FRLS multistrand copper conductor cable of size 16Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCconduit not less than 25mm size ISI marked ivory colour (Pressfit or similar brand ) with allfittings / accessories and 16Sqmm FRLS multistrand copper conductorcable as continuous earth wire complete all as specified and directed.Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesare deemed to be included in the unit rate quoted for this items). 21 S&F Sheet metal enclosure 4 way double door distribution board when MCB to be used TPN 4 way ,415 volt complete all as specified and directed.Make - Seimens/Havells/Legrand/ L&T/ C&S. 22 S&FMCB TPN 63-100Amps 415 volt rupturing cap 10 ka C series complete all as specified and directed.Make - Seimens/Havells/Legrand/ L&T/ C&S. 23 S&F MCBsingle pole, 6 to 32Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. Make - Seimens/Havells/Legrand /L&T/C&S. 24 Supply , installation, testing and commissioning of wall mounted hi wall split inverter type air conditionerunits of capacity 2 TRindoor unit ,outdoor unit complete with cordless remote control unit and with filter for better indoor air quality with minimum 5 star rating for operation on 230V , 50 Hz , single phase AC supply , complete interconnecting copper refrigerant piping , electrical cabling , drain piping , wall sleeve, supporting brackets for outdoor unit , and all necessary fittings , supports , fasteners etc as required complete all as specified and directed. Make - Daikin / Hitachi / O General / LLoyd. 25 S&F electronic wall mounted digital display(Input & output) voltage stabilizerfor automatic voltage correctionsingle phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 10 second of capacity4KVA complete all as specified and directed. Make-V guard/Volina/ Blue bird. 26 S&F Submain wiring with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 04 Sq mmdrawn into and including non metallic medium duty rigid concealedPVCconduit not less than 25mm size ISI markedwith allfittings / accessories and 04 Sq mm FRLS-H multistrand copper conductorcable as continuous earth wire complete all as specified and directed. Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesare deemed to be included in the unit rate quoted for this items.) 27 S&F socket outlet 5 pin 20 amp modular type 2 module with suitable size of module metal flux boxes and including modular front cover plate and back plate for mounting modular type switch & socket with one single poleone module MCB of 20 amp including electrical connection all as specified and directed by Engineer-in-Charge. Make - Havells / ABB/ Goldmedal / Legrand/ L&T. 28 M&L forflame proof pointwiringwith two single core FRLS-H PVC insulated& PVC unsheathed multi stranded copper conductor cable of size 1.5Sqmm1100 voltsgradein and includingstove enamelled steel conduit of size20 to 25 mmwith all accessories and one single core PVC insulated & PVC sheathed multistranded FRLS-H copper cable of size 1.5 Sqmm 1100 Voltsgradeas earthcontinuityconductorconnectedto commonearth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with (1:4) cement morter all as specified for one light / fan point controlled by one 5 Amps flameproofswitch one way complete all as specified and directed. 29 S&F switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed. 30 S&FLED Light Fitting 2x20 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable sizecomplete all as specified and directed. 31 S&F flame proof metallic body exhaust fan single phase 230 Volt 50 Hz 300 mm 1440 RPM with louvers and shutter including civil work i.e making of holes and complete with all fixing accessories all as specified and directed. 32 M & L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt gradedwawn into and including non metallic rigid PVC concelled conduit medium grade 25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of module metal flush boxes and including modular front coverplate & back plate for mounting modular type switches /socket/fan/ regulator etcincluding provision of one single corePVC insulated and unsheathed multi stranded copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dollyswitch board complete all as specified and directed for following-Make of Cable -Polycab/Plaza/Finolex/Havells.One light/fan point controlled by one switch SP 5 Amps ,240 V 33 Ditto all as per item No 32 here-in-before One bell/buzzer point controlled by bell push complete all as specified and directed. 34 Ditto all as per item No 32 here-in-before One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed. 35 Ditto all as per item No 32 here-in-before One 3 pin 5 amps socket point on same board complete all as specified and directed. 36 Ditto all as per the item no 32 herein before but with 2.5 sqmm conductor for5 pin 15 Amps switch socket outlet complete all as specified and directed. 37 S&F switch modular type 1 module single pole, one way 5 Amps complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB/ L&T. 38 S&F switch modular type 1 module single pole, one way 15 Amps complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB / L&T. 39 S&Fsocket outlet 2 in 1, 5 pin, 15Amps modular type 2 module complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB /L&T. 40 S&F socket outlet 5Amps modular type 2 module complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB / L&T. 41 S&F modular Bell push 5 Amps complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB /L&T. 42 M&L for ceiling rose,PVC/polycarbonate, isolated body complete all as specified and directed. 43 S&F stepped type electronic fan regulator modular type 1 module complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB or equivalent 44 S&F bell, ding dong type AC, 230 Volt, single pole. complete all as specified and directed. 45 S&F LED batten light fittings 18/20 watt ,220 volt AC, connecting up with 3 core flexible cable copper conductor of suitable size from ceiling rose complete all as specified and directed. .Make:- Havells/Phillips/Bajaj L&T 46 Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed. Note : GI pipe shall be measured and paid separately under relevant items given here-in-after. 47 M&L for copper strip of size 20 mm x 3 mm complete with saddles , insulators and fixing screws for fitting the strip for earth continuty conductor up to test points and up to Electrical equipments complete all as specified and directed . 48 M&L for GI strip of size 25 mm x 4 mm complete with saddles , insulators and fixing screws for fitting the strip for earth continuty conductor up to test points and up to Electrical equipments complete all as specified and directed . 49 Supply and layinggalvanised iron tubing, 40 mm bore,light grade protection of earth strip pipe with all fittings forfixed to pole/wall/ in ground including all fixing accessories completeall as specified and as directed.Make- Jindal/TATA / Prakash Surya.
Contract Date: Jan 01, 2026 Contract Value : 23.91 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
39.
Tourism #11085444 Technical Bid
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer. , Supplying And Filling Moorum In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry In Cement Mortar 1:3 (1Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg /Cm2. B. Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs, Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of Sail, Tata, Vizag Made Only (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. Minimum Grade Of Steel - Fe 500 , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4B Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint.In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Providing & Fixing In Position Galvalume/Zincalume Flashings, Cappings, Ridges, Gutters Upto 600Mm/610Mm Girth And Min 3.00M In Length (Cold Rolled Steel 550 Mpa Yeild Stress Astm A 446 Grade E) With Hot-Dip Metallic Coating Of Aluminium-Zinc Alloy(Az 150 Galvalume) (150 Gms/Sqm Total Of Both Sides With Al-Zn Composition= 55% & 43.5% Resp. & 1.5% Si Conforming To Astm 792/ As 1397) 0.45 Mm Base Metal Thickness And 0.50Mm Total Coated Thickness, Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respects With Az 150 Gsm Smp Color Coated (20Mic Exterior Coat Of Silicon Modified Polyester Paint System Over 5 Mic Primer And 5 Mic Polyester Back Coat Over 5 Mic Primer) Incl. Fixing To Purlins With No 12X14X55Mm Mechanically Galvanised Hex Head Self Drilling Screws Of The Best Quality As Per As-3566 Class 3-4 Approved, Which Should Be Compatible To Be Used With Sheets. With Integral Washers And Epdm Seals Etc. Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. Plain Grill , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excludingfixingaccessoriessuchasnuts,Bolts, Fasteners Etc.). , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. Light Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Jet Black With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. ( Price Range 2000 To 2100 Rs Per Sq Mtr.) , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. ( Price Range 1550 To 1600 Rs Per Sq Mtr.) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm .80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Fixing 18Mm Thick Polished Black Granite Machine Cut For Kitchen Platforms, Counters, Window Sills, Door Frame, Urinal Partitions , Fascia And Similar Locations Of Required Size Of Approved Shade, Colour And Texture Laid Over 20Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing,Moulding And Polishing To Edge To Give High Gloss Finish, Etc. Complete At All Levels.( Price Range Rs.1500 To Rs.1700 Per. Sq.M ) , Providing 25Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 60 Cm L X45 Cm H X 15 Cm T , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand). 20 Mm Thick. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 (1 Cement: 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , 12 Mm Thick Cement Plaster 1:4 (1 Cement:4 Fine Sand) , 6Mm Thick Cement Plaster To Ceiling With 1:3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer , Extra For Plastering Done On Moldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws , Plugs And Priming Coat On Unexposed Surfaces Etc. 50X12Mm Size. , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 300X 16 X 5 Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Provided And Fixing 150 Mm Chromium Plated Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutters Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete. 200 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Window With 3 Tracks And 2 Shutters Sliding Window With Tobular Frame Ployster Powder If Thicness 75-80 Microns With Approved Standard Accessaries Such As Ball Beaing Rollers, Concealed Lock, 6Mm Thick Plain Clear Glass With Epdm Beading Etc. , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete. 10 Mm Dia , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete.12 Mm Dia , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead Extra For Dismantling Trusses, Rafters, Purlins Etc. Of Steel Work, For Every Additional Span Of One Meter Or Part Thereof Beyond 10 Mts. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead. Of Area 3 Sq.M. And Below , Dismantling Wood Work Of Area Below 40 Sq.Cm. Wrought Framed And Fixed In Frames, Other Frames And Trusses Including Stacking Of Material Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Nandi In Frp As Per Tender Drawing , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Laying 300X350X160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete) , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Saraca Ashoka , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Nyctanthes , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Filliciam Decipiens , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Dichotoma , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Millingtonia Hortensis , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Jacaranda Mimosifolia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neolamarckia Cadamba , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevetia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Alba , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Dual Flushing (Citren Nelson/ Similar)With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vacuum Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. (Excluding Handicap Toilets) , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430 X 260 X 350 Mm And 340 X 430 X 265 Mm Sizes Respectively With Pvc Automatic Flushing Cistern With Fittings, R.S. Or C.I. Brackets, Standard Size Galvanized Steel Flush Pipe And Spreaders With Brass Unions & G.I. Clamps Complete, Including Painting Of Cistern And Fittings, Cutting And Making Good The Walls And Floors Where Required. (A)One Urinal Basin With 5 Liters P .V .C. Automatic Flushing Cistern. , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required. Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws. Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Wall Mixer With 3 In 1 System With 115Mm Long Bend Pipe For Connection To Over Head Shower Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing C.P. Brass Towel Rail Complete With C.P. Brass Brackets Fixed To Wooden Cleats With C. P. Brass Screws. 750X20 , Providing & Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Cp Brass Screw , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed .110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed. 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating.110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door :110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door :110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door . 75Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Providing And Fixing R.P.V.C. Vent Cowl: 75Mm , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Cm2 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar. , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:.B) 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 32Mm Outer Dia. , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 15Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 40 Mm Nominal Bore . , Providing And Fixing Non-Return Valve Of Approved Quality :40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality .25 Mm Nominal Bore , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 25 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 32 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 40 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 50 Mm , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701;1996. 1000 Lit. Capacity , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70B50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Wall Mounted Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Complete. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (B) 10 To 40 A , Supply, Installation, Testing And Commissioning Of 3 Kva 1 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Square / Circular Max. 20 W Pendent Light With Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd10%, P.F. 0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Suspended Accessories Complete. , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii))
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
40.
Housing Urban and Rular Development #11068698 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres: As Directed By Engineer-In-Charge. Note :Stockpile The Top Layer Of Soil Of 200 Mm And Cover It For Reuse In Landscape (If Soild Is Fertile Or Capable To Make It Fertile), Soil Test To Be Performed From Icar Lab As Per Green Building Guidelines , Ordinary Rock 20% , All Kinds Of Soil 80% , Filling Available Excavated Earth (Excluding Rock) In Trenches Plinth, Sides Of Foundation Etc In Layer Not Exceeding 20Cm In Depth Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50Cm And Lead Up To 50 M And Lift Upto 1.5 Mtr. , Stone Solling Dumping Of Stone Including Cost Of Stone (In Horizontal On Level) , Providing And Laying Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 20 Mm Nominal Size) (Crushed) (Use Of Portland Pozzolana Cement Is Advised As Per Green Building Guidelines Or 25% Replacement Of Ordinary Portland Cement With Fly Ash By Weight Of Cement Used In Structural Concrete.) , Providing And Laying Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering. All Work Upto Plinth Level 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) (Crushed) (Use Of Portland Pozzolana Cement Is Advised As Per Green Building Guidelines Or 25% Replacement Of Ordinary Portland Cement With Fly Ash By Weight Of Cement Used In Structural Concrete.) , Cement Concrete Flooring 1:2:4 (1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry And Curing Complete, But Excluding The Cost Of Nosing Of Steps Etc. Complete.50 Mm Thick With 20Mm Nominal Size Stone Aggregate. , Reinforced Cement Concrete Work In Footing , Pedestal ,Columns , Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With M20 (1:1.5:3) (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Foundation, Footing Bases Of Column , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform. , Providing & Fixing Stabilized Mud Concrete Solid Blocks (Adobe) With 3% Cement, Masonry Up To Floor Five Level Including Hoisting And Setting In Position In Mud Mortar Using Approved Quality Mud With Carriage Of Material Complete. , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Seperately) First Class Deodar Wood , Providing And Fixing Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Seperately,All Complete As Per Direction Of Engineer-In-Charge.(Second Class Kail Wood 35 Mm Thick Shutter) , Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick.Second Class Kail Wood. , Providing And Fixing Dgu Float Glass 4 Mm Thick Glass Pane (Weighing Not Less Than 10 Kg/Sqm) , Cement Plaster (In Coarse Sand) 12Mm Cement Plaster Of Mix 1 : 4 ( 1 Cement : 4 Coarse Sand) (Ppc Or Cement With 25% Flyash Is Recommended As Per Green Building Guidelines.) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade On New Work (Two Or More Coats) Over And Including Priming Coat With Water Thinnable Cement Primer (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) Mud Colour , New Work (Two Or More Coats Applied @ 1.43 Litre/10 Sqm. Over & Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Preparing Newly Primed Wooden Surface For Painting By Way Of Filling Of Putty Sand Papering Rubbing Complete. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work. (Note: It Should Have Low Or No Voc As Per Green Building Guidelines) , Providing & Fixing Finished Brass Hanging Type Floor Door Stopper With Necessary Screws Etc Complete. , Providing And Laying Vitrified Non Silipery Floor Tiles In Different Sizes (Thickness Tobe Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete I.E Size Of Tile 600X600 Mm ( Kajaria/Somany/Cera Or Any Approved Brand As Per Engineer In Charge) , Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 6 Mm Nominal Size) As Per Direction Of Engineer-In-Charge And Finished Smooth. , Flooring With Marble Stone Of Specified Thickness As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse Sand) Laid And Jointed With Grey Cement Slurry Including Rubbing, Polishing And Curing Complete With: , providing and Fixing 1St Quality Ceramic Glazed Wall Tiles Conforming To Is:15622 (Thickness To Be Specified By The Manufacturer) Of Approved Make In Colours, Shades Except Burgundy Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps, And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Course Sand) And Jointing With Grey Cement Slurry @3.3Kg/Sqm Including Pointing The Joint With White Cement And Matching Pigments Etc., Complete. , Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan) With 100 Mm Sand Cast Iron P Or Strap, 10 Litre Low Level P.V. C. Flushing Cistern Including Flush Pipe (Of Approved Make) Manually Controled Device (Handle Lever) Conforming To Is:7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required. (Note : It Should Have Flush Rate Of With Flush Rate Of 2/4 Litre Per Flush Or Less ) (Dual Flush 2/4L Wc Cistern With Bottom Inlet For Compact Back To Wall Rimless Toilet As Per Green Building Guidelines) , Orissa Pattern White Vitreous China W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests. Jaguar/Cera Make , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C . .Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern Including Flush Pipe With Manually Controlled Device (Handle Lever) Conforming To Is:7231, With All Fittings And Fixtures, Complete Including Cutting And Making Good The Walls And Floors Wherever Requied: , W.C. Pan With Lsi Marked White Solid Plastic Seat And Lid. Jaguar/Cera Make , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Wallsand Floors Wherever Required : Single Half Stall Urinal With 5 Litre P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.I./M.S. Brackets, 15Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required: , White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps Jaguar / Cera/Hindware Make , providing and Fixing Of Mirrors Of Superior Glass With Plastic Moulded Frame(Of Approved Quality) And Of Required Size And Shape. With 6Mm Thick Hard Board Backing. Rectangular Shape 1500 X 450 Mm , Providing And Fixing Soil Waste & Vent Pipe (Prince Or Any Other Appoved Brand As Per Engineer In Charge , Pvc Pipe. 110Mm Dia (10 Feet Unit Length) , Pvc Pipe. 75Mm Dia (10 Feet Unit Length) , Pvc Bend 110Mm Dia , Pvc Bend 75Mm Dia , Pvc Tee 110Mm Dia , Pvc Tee 75Mm Dia , Pvc Collar 110Mm Dia , Pvc Collar 75Mm Dia , Pvc Trap 110Mm Dia , Pvc Trap 75Mm Dia , Pvc Socket 110Mm Dia , Pvc Socket 75Mm Dia , Pvc Door Junction 110Mm Dia , Pvc Door Junction 75Mm Dia , Providing And Fixing 3 Layer Thermex Pipe Pp-R (Poly Propylene Random Copolymer)Pipes Conforming To Is: 15801, Uv Stabilized And Anti-Microbial Fusion Welded, Having Thermal Stability For Hot And Cold Water Supply Including All Pp-R Plain And Brass Threaded Polypropylene Random Fittings. This Includes Testing Of Joints Complete As Per Direction Of Engineer-Incharge.Internal Work Concealed Fixing The Pipe With Clamps At 1.00 Meter Spacing Including Cutting Chases And Making Good The Wall Etc. , Pn-16 Pipe , 25Mm Od(Sdr-7.4) , Pn-16 Pipe , 32Mm Od(Sdr-7.4) , providing and Fixing Cp Brass Toilet Paper Holder Including Cost Of Wodden,Pvc,Play Etc. , Providing And Fixing Wall Mount Liquid Soap Dispenser Of Approved Brand , Providing And Fixing Accessories Of Standard And Quality Make Of Approved Manufacturer Including All Necessary Fixtures Required. , L-Drops For Room Door , T-Bolt For Room Doors / Windows , Handles For Doors & Windows , 15 Mm C.P. Brass Tap With Elbow Operation Lever , 15 Mm C.P. Brass 2 In 1 Tap Of Approved Quality Conforming To Is Standards , 15 Mm Nominal Bore C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms , C.P. Brass Extension Nipple (Size 15Mmx50mm) Of Approved Make And Quality As Per Direction Of Engineer-Incharge. , 15 Mm Nominal Bore Of Standard Back Type C.P. Brass Close Hole Basin Mixer Pillar Tap Including All Necessary Accessories Of Approved Quality And Make, Weighing Not Less Than 1.970 Kg. , High Water Pressure S.S Geyser Connection Pipe (2 Feet Long) Of Approved Quality And Make, , Supply Installation Testing And Commissioning Of Geyser 30Ltr Capacity Horizontally Mounted Of Approved Brand (Havells/Bajaj/Crompton Or Any Othet Approved Brand As Per Engineer In Charge Including All Fixtures , Bolts All Complete , 15 Mm Nominal Bore C.P. Brass Long Angle Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms , Providing And Installation Of Puf (Puf Insulated Tanks) Water Tank Capacity 1000 Ltrs Of Approved Brand (Syntex Or Any Other Approved Brand) As Per Direction Engineer Incharge , Supply And Installation Of High Quality Self Regulating Heat Tracer For Specialized Heating Solutions For Winterisation Of Water Pipeline Including All Accessories Complete Including Supply And Installation Of Circuit Control Panel With Rcbo Mcb ,Thermostat (0-120) Deg C, Power Connector-Two Way-6 Sq.Mm, W.P. Splice Connector,W.P. Tee Connector,End Seal,Mounting Kit-W.P. Jb,G.I. Pipe Strap 4,Al. Adhesive Tape Roll ( 50 Mm W X 20 M L),F.G. Adhesive Tape Roll (Danfoss Make Or Chromalox Any Other Approved Brand As Per The Direction Of Engineer-In-Charge) , Supplying And Fixing High Quality 32Mm Thick Nitrile Insulation Tube For Water Pipeline Of Approved Brand 2 Inch Size (Armaflex Class-O Armacell), Rock Wool Including Alumunium Duct Clading (Alumunium Sheet Guage Thickness = 0.46Mm To 0.71Mm )Of Approved Quality And Finish As Per The Direction Of Engineer In Charge , Providing Corrugated G. S. Sheet Roofing Including Vertical/Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Upto Any Pitch In Horizontal/Vertical Or Curved Surface)Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gram/M2 , Providing Of Fabricated Steel Roofing Truss, Purlins, Rafters, Posts, Plates Isa.65X65x6mm ,Isa.50X50x6mm, 40X40x6mm, Ismc 75Mm ,65Mm,50Mm,Plates 8Mm,10Mm Thick, Weather Boarding, Eves Boarding, Valley Angle Etc. Including Cutting Hoisting Fixing In Position And Applying A Priming Two Or More Coat Of Approved Steel Priming/Painting All Work Complete Job. Including Launching Of Trusses , Septic Tank , Earth Work In Excavation By Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 Min Width Or10sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms,Lift Upto 1.5M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , In All Kind Of Soil 30% , Ordianary Rock 30% , Hard Rock (Blasting Prohibited 40% , Stone Soling Hand Packed Including Carriage And Cost Of Stone , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 1:2:4(1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Leveling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20Mm Nominal Size) Upto Plinth Level And Curing Complete With: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Wall , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Slab , Cement Concrete Flooring 1:2:4 (1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry And Curing Complete, But Excluding The Cost Of Nosing Of Steps Etc Complete 50Mm Thick With 12.5 Mm Nominal Size Stone Aggregate. , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 13
Jammu And Kashmir View Result →
41.
Educational and Research Institute #11059846 Price Bid
Tender For Equipment; Purchase of Equipment: Rotary evaporator with accessories Rotavapor V-Condenser P+G assembly Cooling capacity1500cm/hour with Drive unit 3 inch Dark Segment Display for Rotation speed, lift position and heating bath temperature (set and actual value) displayed on the Heating Bath Base. Allows user to monitor all parameters at a glance., Motor lift with 10-330 RPM, Limit position detection adjustment range Vertical 180mm, Immersion Angle 15-52.5° (Adjustable with 7 Stages), Flask Sizes Uses from 50ml....3000 ml Capacity Safety Stop: Automatic operation stop by power failure, Lifts flask automatically out of heating bath Manually adjustable via button within a range of 100 mm prevents glass breakage and damage to bath pan Patented multifunctional Combi-Clip for evaporating flask fixation and removal, as well as vapor duct release Allows one handed flask removal 1 liter evaporating flask NS 29/32 and 1 liter receiving flask, Protection Class IP42, CE CSA & ISO 9001 Certified Lift height indication Position is digitally indicated on display of heating bath and Key button Lock function Heating Bath, Digital Display heating bath temperature range of up to....95°C Kettle Connection: Cordless bath Allows easy emptying and refilling of bath without unplugging Infrared communication: Transition of heating bath data to interface Maximum Bath Capacity 4.2 Litre, Digital temperature display allows adjusting set temperature and indicates actual temperature Over Heat Protection: Cut off power when actual temperature exceeds set temperature or by rapid temperature increase Protection Class IP21, CE/ISO 9001 Certified, Heating Power 1300W Vacuum Controller, 3 Dark Segment Digital Display controller indicating, adjusting and controlling the vacuum. Special features like a) measure and display the pressure, b) Regulate the vacuum pump speed & c) Start/Stop the vacuum pump Manually regulate the system leakage using a needle valve, Two operating modes (manual, timer), Measuring Range: 1400-0 mbar, Control range: 1100-0 mbar, Hysteresis Automatic or 1 - 500 mbar Measuring Accuracy: +2mbar (+)- after calibration at constant temperature Protection Class IP44, CE/CB/UL/CSA Certified, Along with woulff bottle for Trap Vacuum Pump,- 100% Solvent recovery DC motor Brushless vacuum pump pump for reusable Speed control chemical resistant PTFE diaphragm DC motor Brushless vacuum pump Achieve more than 90% solvent recovery and reusable using interface, Vacuum generation optimally suited to work with the Rotavapor. Final vacuum: 13 mbar (with Gas Ballast), Flow Rate: 1.3 m3/h. InOn/Off.control the pump is automaticallız turned On and Offseis the interfece On/Off communication
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
42.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
43.
Housing Urban and Rular Development #11047139 Technical Bid
Tender For 1. Supply, Installation, Testing And Commissioning Of Walk In Cold Room Made Of 100 Mm Puf Panels With Ppgi For Internal And External Surface For Cold Room Along With Other Accessories Having 01 No. Of The 34 To 40(W) X 72 To 80(H) Flush Door 100Mm Ppgi Finish Both Sides. The Job Includes Civil Works As Per Necessity And Other Allied Works At Site. The Puf Panels Shall Be Of Make Sintex /Lloyd/Jindal. Material To Be Stored : Blood Samples Ambient Temperature: =450C Room Temperature : 20C Pull Down Time : =20 Hrs Room Size (External) : 10×8×10 Cold Room Structure: 1) Room Size (External) : 10×8×10 2) Door Size: 34 To 40(W) X 72 To 80(H) 3) Door Type: 100Mm Ppgi Both Side Flush Type Door, Plastic Curtains On The Door Way, Flush Type Door With Kick Plate At Bottom And Fitted With Door Closer, Examination Window (View Port), Seal Closer Mechanism. Heavy Duty Lock - Lockable With 100% Fail-Safe Provision For Opening From Inside. 4) Wall Panels: 100 Mm Thick Puf Wall Panels With Density Of 40±2 Kg/M3 For Cold Room With Cam Lock For Puf Panels Inter Locking. 5) Panel Finish: Ppgi For Both Sides Of Panel (Corrosion And Moisture Resistant) 6) Flooring: Aluminum Checker Plate 10 Guage Or 3Mm Thick With Over Insulated Base Refrigeration System: Supply, Installation, Testing And Commissioning Of 01 No. Refrigeration Units (One Main And One Standby Cold Room Machine) Of Minimum Of 24000 Btu/Hr Capacity Each Along With Evaporator Make: Bluestar, Voltas, Carrier. Job Also Includes Supply And Installation Of Other Accessories Such As Expansion Valve, Control Panels, U Flashings, Inner Flashings And Flat Flashings And Sealant Etc. As Per Site Requirement. Supply And Installation Of Ms Frame In Position And Applying A Priming Coat Of Approved Steel Primer For Odu Unit And For Isolator Mcb With Box With Electrical Wire With Copper Piping, Drain Work And Other Civil Work As Per Site. 1) Temperature Range: +1°C To +6°C 2) Refrigerant: Eco-Friendly As Per Norms/Design 3) System: Air-Cooled 4) Compressor: Reciprocating/Rotary 5) Cooling Capacity: Min. 24000Btu/Hr @-4 Evap. Temp. And Condensing Temp Of 540C 6) Number Of Cdu: 01 No. 7) Evaporator: Min. 24000Btu/Hr 8) No. Of Evaporator: 01 No With 03 Nos Of Fans: 9) Supply: Three Phase 10) Electric Load: 2.8Kw/Hr (Approx.) 11) Automatic Voltage Stabilizer: 7.5 Kva 3 Phase Along With Supply Installation Testing And Commissioning Of Required Assorted Size Cables As Per Site Requirements For Commissioning And Running Of Whole Installed System. Electrification: Proper Electrification Of Cold Storage Room By Way Of Providing And Installation Of Power Points, Lighting, Fans Along With Electric Cables Of Assorted Sizes As Per Site Requirement. Complete Job Includes Tapping Of Power Supply From The Main Panel With Cost Of Material, Labour Charges And All Kind Of Taxes Thereof. Complete Job With Cost Of Material, Labour Charges And All Kind Of Taxes Thereof. , Supply And Fixing Of 04 Nos. Ss-304 Adjustable Rack Of Size 4-0X 8-0X1-0 With Sheet Thickness 1.0/0.8 Mm In Position Along With Required Allied Works For Medicine Storage Size As Per Medical Standards. , Chemical Earthing Of Db By Way Of Excavation Of 01 No. Pit Of Proper Size Upto A Depth Of 03M For Providing And Laying Of 03 Meter Copper Electrode 01 Nos. In Hard And Soft Soil Followed By Filling Of Required Quantity Of Earthing Chemical. Job Includes Filling Of Pit With Excavated Soil And Fitment Of Copper Electrode With Copper Strip From Electrode To Machine. Complete Job With Cost Of Material, Labour Charges And All Kind Of Taxes Thereof. , Electrical Work- Providing And Fitting Of 02 Nos. Tpn, Distribution Board, Aluminum (Armoured) 25Sqmmx4 Core - 30 Mtrs, 6 Sq.Mm Copper Cable- 60 Mtrs. , Miscellaneous Work- Job Includes Minor Civil Works And Repairs To The Wall Plaster Wherever Necessary, Alarm System For Trapped Person, Loading, All Type Of Miscellaneous Framework, Unloading, Freight, Lock System, Etc , Supply Installation Testing And Commissioning Of 2.0 Tr Split Air Conditioners (Hot And Cold) With All Accessories (Along With Outdoor Stand) And Ambient Upper Temperature Range Of = 52 Degree Celsius For Cooling With Maximum Cooling Capacity = 6500 W And For Heating Ambient Lower Temperature Range = 0 Degree Celsius With Maximum Heating Capacity = 6000 W Having Air Flow Rate =590 Cfm With Minimum 3 Star And Of Reputed Make I.E., O-General, Mitsubishi, Daikin, Hitachi, Bluestar Along With Allied Accessories I.E. Minimum Of 10 Of Refrigerant Pipes And Communication Cable. Complete Job As Per Site Requirement And Instructions Of Engineer-In-Charge And Also Includes Cost Of Materials, Labour Charges, Transportation Charges And All Other Charges. , Supply, Installation, Testing And Commissioning Of 5Kva Copper Wound Automatic Wall Mounted Voltage Stabilizer Input Voltage Range Of 90-300V & Of Superior Quality Isi Mark For Acs. Make: Microtek/Aulten/Servokon/Electricfield , Providing And Fitting Of Spn Of 40 Annual Periodical Maintenance Of Reputed Make I.E. Havells, L&T With Cover (Complete With Fittings) For 2.0 Tr Capacity Acs To Be Installed. , Providing And Fitting Of Extra Copper Pipe With Insulation. , Providing And Laying (Using Conduits And Wire Fasteners / Cable Clips) ) Of 10 Sq Mm 4 Core Multistrand Flexible Isi Marked, Frls Pvc Insulated Copper Conductor Cable And Of Standard Make I.E. Havells, Polycab, Finolex, Anchor Only For The Purpose Of Connecting Stabilizers To The Electrical Panel. Complete Job As Per Instructions Of Engineer-In-Charge And Site Requirements And Also Includes Cost Of Materials (Including Clamps, Bends/Elbows, Tee-Bends, Thimbles Etc.), Labour Charges, Transportation Charges And All Other Charges And Taxes. , Providing And Laying Of (Using Conduits And Wire Fasteners / Cable Clips/Conduit Fasteners) 4 Sq Mm Isi Marked, Frls Pvc Insulated Copper Conductor Cable Of Standard Make I.E. Havells, Polycab, Finolex, Anchor Only For The Purpose Of Connecting Air Conditioning Units (Outer & Inner) To The Stabilizer. Complete Job As Per Instructions Of Engineer-In-Charge And Site Requirements And Also Includes Cost Of Materials (Including Clamps, Bends/Elbows, Tee-Bends, Thimbles Etc.), Labour Charges, Transportation Charges And All Other Charges And Taxes. , Providing And Laying Of Pvc Drain Pipes Of Assorted Sizes Viz. ¾, Etc. To Collect And Transport The Drained Water From The Ac Unit To A Designated Location, Considering The Specific Requirements Of The Site. The Pvc Pipes Will Be Installed With Appropriate Size Bends And Clamps To Ensure Proper Alignment And Secure Connections. Job Also Includes Miscellaneous Works Civil Works Like Wall Opening To Pass Ducts & Pipes, Plastering & Refinishing Of The Same To The Original Finish As Per The Site Requirements. Complete Job As Per Instructions Of Engineer-In-Charge And Site Requirements And Includes Cost Of Materials (Including Clamps, Bends/Elbows, Nipples, Tee-Bends, Etc.), Labour Charges, Transportation Charges And All Other Charges And Tax. , Providing, Fitting And Testing Of Air Curtains At The Main Entrance Of Blood Bank At Gmch Jammu The Air Curtain Should Be In A Metal Casing, Strong, Fire Resistant, Simple Installation And Easy Cleaning. They Should Have Double Air Way Deflectors Design Obtaining An Even Air Stream So That It Creates An Invisible Air Barrier Over The Doorway That Prevents The Inner Cool/Warm Air From Going Outside And Also Prevents Insects , Dust Etc From Entering Inside The Ward. All The Air Curtains Have To Be Fixed On The 8 Mm Ply Board Fitted And Hung By Sides . The Specifications Of Air Curtain Should Be: Material Of Cabin-- Cold Rolled Mild Steel 1. Base Plate- 16 Swg 2.Body- 18 Swg 3.Grilles- 20 Swg 4. Blower Housing- 20 Swg 5. Length- 6.00 Of Curtain Interior Finish- Anti Rust Treatment With Primer Paint, Exterior Finish- Ht Paint/Stove Painting (Powder Coating), Fans And Motors- The Multiple Forward Curved Centrifugal Type Aluminum Fan Wheels Statically And Dynamically Balanced Driven By Extended Motor Shaft. The Job Also Includes Providing And Fitting Of 4Mm Sq Wire Of Suitable Length To Be Connected To The Main Power Supplies Of Each Unit, Spns- 1 Nos With Covers, Baton, Pvc Clamps And Gutties Etc As Per Site Requirement Complete Job Includes Cost Of Material, Transportation, Labour Charges And All Types Of Taxes. , Repair And Cleaning Of Ducts Of Air Conditioning At Various Locations Of Blood Bank Of Gmch Jammu By Way Of Removal Of Vent Grilles And Diffusers For Manual Cleaning Using Industrial-Grade Hepa-Filtered Vacuums, Soft-Bristle Brushes, And Compressed Air Tools To Eliminate Dust, Debris, And Other Particulate Buildup From The Visible Portions Of The Duct Openings And Repair To All The Damaged Vents As Per Site Requirement So That The Air Flow Reaches The Last End Duct. All Debris Collected During The Cleaning Will Be Properly Contained And Disposed Of Offsite. After Cleaning, All Vents And Will Be Securely Reinstalled And Airflow Tested To Confirm Proper Operation. A Visual Inspection And Photographic Documentation Of Cleaned Vents Will Be Included In The Final Job Report. The Job Includes Replacement Of Damaged Power Coated Aluminium Extruded Grill. Complete Job Includes Cost Of Material, Consumables,Labour And All Types Of Taxes Etc , Providing And Fitting Of 4K Hdmi Cable 5 Meter , 55 Led Tv 4K For 24X7 Operations With Uhd Dimming And Auto Motion Plus Make: Samsung/Sony/Sansui , Supply & Installation Of 5 Mp Ir Fixed Network Dome/Bullet Camera- Suitable For Outdoor Operation With Following Specifications Along With Accessories Required For Fitting. 30 Meter Ir, 1/2.7 Progressive Scan Cmos Color: 0.0125 Lux @ (F2.0, Agc On) 0 Lux With Ir, Resolution: 2592 × 1944 Or Better ,Wdr Should Be 120Db Or Higher, 3.6Mm,Mic And Speaker Inbuilt , Camera Shall Have Ip67 Ingress Protection And Ce, Fcc, Ul, Rohs,Cmmi-5 , ,Weee Certifications Make: Hi Focus/Matrix/Prama , Supply & Installation Of 16Channel 2 Sata Network Video Recorder-For Encoding And Processing The Video Data At The Camera ,Then Streaming To The Nvr Recorder For Storage And Remote Viewing With Following Specifications And Features. Nvr Shall Support Up To 12 Mp Or Higher,Nvr Shall Support 4K (3840 × 2160) ,Nvr Shall Support 16-Ch Playback,Tcp/Ip, Dhcp, Dns, Ddns, Ntp, Sadp, Smtp, Nfs, Iscsi, Upnp™, Https ,Nvr Shall Support 02 Sata Interface. Nvr Shall Support Up To 16 Tb Capacity For Each Hdd,1 Rj-45 10/100/1000 Mbps, Nvr Shall Support Sh.265,H.265+,H.265,H.264 Video Compression, Onvif Compatible,Shall Have Ce, Fcc, Ul, Bis,Rohs,Cmmi-5 ,Weee Certifications Make: Hi Focus/Matrix/Prama , 4 Tb Av Hdd Make: Seagate/Wd/Toshiba , Providing & Fitting Of Rack 4U With Glass Door And Lock Fully Loaded Conforms To Din 41494 & Iec 297 , Iso 9001:2015 Standards Make: Comrax/ President/Apc , Supply & Installation Of 8 Port Giga Poe Switch, With 8*10/100/1000Mbps Ports1-8 + 2*10/100/1000 Ports 9-10 Poe Ports, Full Duplex ; 1000 Mbps, ,Poe Power Budget: 96W,Standards: Ieee 802.3, Ieee 802.3U, Ieee 802.3Ab Ieee 802.3Xl Ieee, Packet Forwarding Rate: 14.88Mbps, 8K Mac Address Table, Packet Buffer Size 192Kb Make: Hi Focus/Digisol/D-Link/Netgear , Providing & Fitting Of Conduit 25Mm Along With Clamps Etc. , Providing/Supply, Installation, Testing & Commissioning Of Cat-6 Outdoor Cable Cat6 4-Pair U/Utp Outdoor Double-Jacketed Cable With Frequency Range: 1-250 Mhz, 23Awg ( 0.55Mm) Solid Bare Copper Conductor, High-Density Polyethylene(Hpde) Color Coded As Per Ansi/Tia-568 2-D Insulation,Cable Core: 4 Twisted Ppair Held In Place By Hdpe Cross-Web Separator,Water Resistant: Jacket Only,Inner Jacket: Lszh Grey, Outer Diameter:7.0Mm Nominal,Outer Jacket: Uv Resistant Hdpe For Outdoor Use, Black Make: Amp/ Honeywell/Commscope/Comrax , Providing & Laying Of Power Cable With 3 Core ,2.5 Sq.Mm ,Copper Make: Finolex/ Havell/ , 1Kva Online Ups With 60 Minutes Smf Battery Backup With Rack Make: Elnova/Fuji/Apc , Providing And Fitting Of Rj 45 Jacks Which Includes Crimping At Both The Ends Of The Cable , Integration, Testing &Commissioning All The Equipments And System For Proper Functioning
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
44.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
45.
Health and Family Welfare #10901538 Price Bid
Tender for Volume V - Bill Of Quantities Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder General Abstract Sl.No Description Amount (Excl.Gst) , Civil Works , Plumbing Works , Electrical Works , Elv Works , Fire Fighting , Stp (50 Kld) , Building Signages Total Amount (Excl Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Civil Sl No. Dsr/ Morth Code Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , 2.6.1 , 2.26.1 , 2.26.1X2 , 2.8.1 , 2.10.1.2 , 50.2.26.1 , 4.1.2 , 4.1.8 , 4.2.5 , 5.1.3 , 5.9.1 , 5.9.2 , 5.9.3 , 5.9.5 , 5.9.6 , 5.9.7 , 5.9.16.1 , 5.9.19 , 5.11.1 , 5.22.6 , 5.22A.6 , Dsr Analysis 5.33.1.2 , Dsr Analysis 5.33.2.2 , Dsr Analysis 5.33.1.1 , Dsr Analysis 5.33.2.1 , 50.6.2.1 , 50.6.1.4 , 50.6.1.5 , 50.6.1.6 , Dsr Analysis , Dsr Analysis , 7.1.1 , 8.2.2 , Dsr Analysis , 8.3.2 , Dsr Analysis , Dsr Analysis , Dsr Analysis , 11.3.1 , 11.6.1 , 11.20.3 , 11.41.2 , 11.46.2 , 11.41A.3.1 , Dsr Analysis , Dsr Analysis , 11.56.1 , 12.52.3 12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Size 595X595 Mm Made Of Gypsum Plasterboard , Manufactured From Natural Gypsum As Per Is 2095 Part I And Laminated With White 0.16 Mm Thick Fire Retardant Pvc Film On The Face Side And 12 Micron Metalized Polyster On The Back Side With All Edges Sealed With The Face Side Pvc Film Which Goes Around And Wraps The Edges And Is Bonded To The Edges And The Back Side Metalized Polyster Film So As To Make The Tile A Completely Sealed Unit. Sqm 232.88 29 0.0 , 12.52.1 Gi Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of Gi Sheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending Sqm 1235.61 29 0.0 , 12.59.1 Calcium Silicate Board To Ceiling Section And Perimeter Channels With The Help Of Day Wall Screws Of Size 3.5X25mm At 230Mm C/C, Including Jointing Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compounds, Jointing Tapes, Finishing With Jointing Compounds In Three Layers Covering Up To 150Mm On Both Sides Of Joints And Two Coats Of Primer Suitable For Boards, All As Per Manufactures Specification And Also Including The Cost Of Making Opening For Light Fittings, Grills, Diffusers, Cut Outs Made With Frame Of Perimeter Channels Suitable Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With 8 Mm Thick Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process. Sqm 782.57 29 0.0 , 13.1.1 , 13.4.1 , 13.16.1 , 13.33.1 , 13.22 , Dsr Analysis , 13.43.1 , 13.45.1 , 13.47.1 , 13.60.1 , 13.61.1 , 13.9.1 , 13.21 , Dsr Analysis , 10.6.1 , 10.16.1 , 10.18 , 10.25.1 , 10.25.2 , 10.26.3 , Dsr Analysis , 10.28 , 21.1.1.2 , 21.1.2.2 , 21.2.2 , Dsr Analysis , Dsr Analysis , 21.3.3 , Dsr Analysis , Dsr Analysis , 9.1.1 , 9.5.1.1 , 9.7.1 , 9.71.2 , 9.21.1 , 9.22.1 , 9.24.1 , 9.74.1 , 9.48.2 , 9.97.2 , 21.13 , 9.100.1 , 9.101.2 , 21.4.1 , 9.121 , 9.122.2 , 50.9.15.2 , 9.147A.1 , 9.147A.2 , 9.147A.3 , 9.147A.4 , 9.147A.5 , Dsr Analysis , Dsr Analysis , 21.11.3 , 21.15.2 , 22.4.1 , Dsr Analysis , Mr Door Leaf Should Be Minimum 60Mm Thick Fully Flush Double Skin Door. Door Leaf Must Be Manufactured From 1.2Mm(18 Gauge) Thick Galvanised Steel Sheet. The Infill Material Shall Be Honeycomb Craft Paper Insulation. All Doors Shall Be Factory Prepped For Receiving Appropriate Hardware And Provided With Necessary Reinforcement For Hinges, Locks, And Door Closers. The Edges Should Be Interlocked With A Bending Radius Of 1.4Mm. For Double Leaf Doors Integrated Astragals Has To Be Provided On The Meeting Stile For Both Active And Inactive Leaf. The Shutters Shall Be Mounted To The Frame With Ss 304 Grade Ball Bearing Type Hinges Of Size 100X89x3 Mm Along With All Suitable Hardware (Triple Point Panic Bar, Ss Ball Bearing Hinges, Door Closer, Panic Trim, 6Mm Thick 300X400mm Vision Panel Fire Clear Glass, Etc Complete). Vision Lite Glass Size 300Mm X 400Mm (Max Area Upto 0.12Sqm) Wherever Applicable Should Be Provided With Single Layered Clear Fire Rated Glass Panes As Per Guidelines Laid Down Under Is 3614 : 2021 Vide Clause No. 7.2.7 Table No. 2 With A Clipon Arrangement. The Glass Will Be Provided With Fire Rated Ceramic Tape Of Suitable Size Alround On Either Face. Every Glass Pane Must Carry A Permanent Marking Of Approved Make. Door Must Be Tested With Vision Panel- 6Mm Thick Pyroswiss Glass Of Approved Make.Single Leaf Door. Size : 1000X2250mm Each 7.0 29 0.0 , Mr Door Leaf Should Be Minimum 60Mm Thick Fully Flush Double Skin Door. Door Leaf Must Be Manufactured From 1.2Mm(18 Gauge) Thick Galvanised Steel Sheet. The Infill Material Shall Be Honeycomb Craft Paper Insulation. All Doors Shall Be Factory Prepped For Receiving Appropriate Hardware And Provided With Necessary Reinforcement For Hinges, Locks, And Door Closers. The Edges Should Be Interlocked With A Bending Radius Of 1.4Mm. For Double Leaf Doors Integrated Astragals Has To Be Provided On The Meeting Stile For Both Active And Inactive Leaf. The Shutters Shall Be Mounted To The Frame With Ss 304 Grade Ball Bearing Type Hinges Of Size 100X89x3 Mm Along With All Suitable Hardware (Triple Point Panic Bar, Ss Ball Bearing Hinges, Door Closer, Panic Trim, 6Mm Thick 300X400mm Vision Panel Fire Clear Glass, Etc Complete). Vision Lite Glass Size 300Mm X 400Mm (Max Area Upto 0.12Sqm) Wherever Applicable Should Be Provided With Single Layered Clear Fire Rated Glass Panes As Per Guidelines Laid Down Under Is 3614 : 2021 Vide Clause No. 7.2.7 Table No. 2 With A Clipon Arrangement. The Glass Will Be Provided With Fire Rated Ceramic Tape Of Suitable Size Alround On Either Face. Every Glass Pane Must Carry A Permanent Marking Of Approved Make. Door Must Be Tested With Vision Panel- 6Mm Thick Pyroswiss Glass Of Approved Make. .Single Leaf Door. Size : 1200X2250mm Each 9.0 29 0.0 , Mr Door Shutter: The Double Skin Single Leaf Door Shutter Shall Be Consisting Of Minimum 46 Mm Thick And Having Box Like Structure, Slots Cut And Holes Punched, For Fixing Of Hardwares With Stiffeners As Per Is: 16074 Including Resin Bonded Honey Comb Paper Core Infill Material Of Density 5 Kg/Cum. The Door Shutter Shall Be Mounted On The Frame With Ss 304 Grade Ball Bearing Butt Hinges As Per En 1935: 2002 Or Butt Hinges As Per Is 12817 Both, Of Minimum Size 100X75x3 Mm @ Minimum 4 Numbers Up To 2100 Mm/2400 Mm Height Or As Per Test Evidence,Which Ever Is More, Fixed With M6 25 Screws. All Doors Shall Be Factory Prepared For Receiving Appropriate Hardware And Provided With Necessary Reinforcement For Hardware Accessories. Hardware Accessories Fire Doorset Assembly Shall Be Provided With One Number Fire Rated Ss 304 Shaft Mortise Dead Lock, One Number 50-80 Mm Back Set With Minimum 20 Mm Square Forend With Allen Key Including Ss304 Dead Strike Plate Conforming To Is: 16015:2022/En 12209, One Number Recessed Flush Pull Handle (Ss304) Of Minimum Size 40 Mm X 120 Mm, As Approved By Engineer-In-Charge. Finishing: Both Frame And Door Shutters Shall Be Factory Finished With Polyester Powder Coating Of Minimum 50 Microns Thick And Shall Have Passed Salt Spray Test As Per Is:13871 Of Approved Colour And Shade All Complete As Per Manufacturers Specifications And As Per Direction Of The Engineer-In-Charge. Installation: The Hollow Space In The Door Frame Shall Be Filled / Injected With Fire Rated Self Extinguishing Type Polyurethane Foam (Puf) After Installation At Site Of Work. The Rate Shall Be Inclusive Of Complete Fire Rated Door Assembly, Supply And Installation By The Approved Manufacturer. Single Leaf Uninsulated Metal Fire Rated Door And Frame Of Fd 120Ud With 120Minits Integrity Only As Per Is 3614:2021-For Non Egress Application Like Area Shafts Etc Sqm 21.6 29 0.0 , 22.22 , 22.23.2 , 19.16 , Dsr Analysis , Dsr Analysis , Dsr Analysis , 15.18 , 15.7.4 , 15.9.2 , Dsr Analysis , 16.68 , 16.69 , 16.91.2 , Morth 4.1.A.1 , Morth 4.12 , Morth 5.3.1.A , Morth 5.6.1.A , Morth 5.1.A , Morth 5.2.B Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Plumbing Item No Dsr Code Details Of Item Unit Quantity Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) Plumbing Sanitory Fixrtures And Fittings , 17.3.2 , 8.10.2 , 17.10.1.1 , 17.69.2 , 17.31 , 17.72 , 17.71 , 18.21.2.1 , 18.53.1 , 18.65 , 50.17.1.2 , 17.32.4 , 18.8.1 , 18.8.2 , 18.8.3 , 18.8.4 , 18.17.1 , 18.17.1A , 18.17.2 , 18.17.3 , 18.17.4 , 12.44 , 18.48 , 17.70.1 , 19.6.3 , 19.7.1.1 , 19.8.1.1 , 19.16 , 2.10.1.2 , 19.8.2.1 , 19.7.2.1 , 19.32.1 , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Electrical Sl. No Dsr No. Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) 1. Wiring , 1.3.1 Lmr 2 X 1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire M 4185.0 29 0.0 1.3.2 Lmr 2 X 2.5 Sq.Mm + 1X 2.5 Sq.Mm Earth Wire M 8370.0 29 0.0 1.3.3 Lmr 2 X 4 Sq.Mm +1X 4 Sq.Mm Earth Wire M 1395.0 29 0.0 1.3.4 Lmr 2 X 6 Sqmm + 1 X 6 Sqmm Earth Wire M 100.0 29 0.0 , 1.4.1 1.21.1 20 Mm M 50.0 29 0.0 1.4.2 1.21.2 25 Mm M 100.0 29 0.0 1.4.3 1.21.3 32 Mm M 100.0 29 0.0 1.4.4 1.21.4 40 Mm M 50.0 29 0.0 , 1.50.1 , 1.55.3 , 15.4.3 3 Output (1 Output Per Phase) And Suitable For Three Phase Supply 2. Mccb, Mcb & Dbs , 2.3.3 2.3.3 12 Way Double Door Each 5.0 29 0.0 , 2.2.1 2.4.1 4 Way Double Door Each 14.0 29 0.0 2.2.2 2.4.2 6 Way Double Door Each 19.0 29 0.0 2.2.3 2.4.3 8 Way Double Door Each 2.0 29 0.0 , 2.3.1 2.5.1 4 Way Double Door Each 6.0 29 0.0 , 2.4.1 2.10.1 Single Pole Each 370.0 29 0.0 2.4.2 2.10.3 Double Pole Each 10.0 29 0.0 2.4.3 2.10.4 Triple Pole Each 50.0 29 0.0 2.4.4 2.10.5 Triple Pole And Neutral Each 20.0 29 0.0 , 2.6.1 2.12.1 40 Amps Each 5.0 29 0.0 , 2.7.1 2.13.1 40 Amps Each 22.0 29 0.0 2.7.2 2.13.2 63 Amps Each 11.0 29 0.0 , 2.8.1 2.14.1 25 Amps Each 5.0 29 0.0 , 2.9.1 2.15.1 25 Amps Each 4.0 29 0.0 2.9.2 2.15.2 40 Amps Each 15.0 29 0.0 2.9.3 2.15.3 63 Amps Each 15.0 29 0.0 , 2.17 2.12.1 2.24.1 Supplying And Fixing Cable End Box (Loose Wire Box) (Ip 43) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Testing And Commissioning Etc. As Required.For 4 Way, Double Door Tpn Mcbdb Each 14.0 29 0.0 2.12.2 2.24.2 Supplying And Fixing Cable End Box (Loose Wire Box) (Ip 43) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Tpn Mcbdb Each 19.0 29 0.0 2.12.3 2.24.3 Supplying And Fixing Cable End Box (Loose Wire Box) (Ip 43) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Testing And Commissioning Etc. As Required.For 8 Way, Double Door Tpn Mcbdb Each 2.0 29 0.0 2.12.4 90.11.1.15 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required 6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 4.0 29 0.0 2.12.5 90.11.1.18 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 2.0 29 0.0 2.12.6 90.11.1.19 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 2.0 29 0.0 2.12.7 90.11.1.20 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required8 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) Each 3.0 29 0.0 3. Cable Tray , 4.6.2 , 4.6.4 , 4.6.6 , 4.6.7 4. Earthing , 5.19 5. Mv Cable Laying , 5.1.1 7.1.1 Upto 35 Sq. Mm M 1650.0 29 0.0 , 5.2.1 7.5.2 Above 35 Sq. Mm And Upto 95 Sq. Mm M 720.0 29 0.0 5.2.2 7.5.4 Above 185 Sq. Mm And Upto 400 Sq. Mm M 420.0 29 0.0 , 7.6 5.3.1 7.6.4 Above 185 Sq. Mm And Upto 400 Sq. Mm M 330.0 29 0.0 , 5.4.1 7.7.1 Upto 35 Sq. Mm (Clamped With 1Mm Thick Saddle) M 985.0 29 0.0 5.4.2 7.7.2 Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) M 175.0 29 0.0 5.4.3 7.7.3 Above 95 Sq. Mm And Upto 185 Sq. Mm (Clamped With 25/40X3mm Ms Flat Clamp) M 25.0 29 0.0 5.4.4 7.7.4 Above 185 Sq. Mm And Upto 400 Sq. Mm (Clamped With 40X3mm Ms Flat Clamp) M 50.0 29 0.0 , 5.5.1 7.8.1 Upto 35 Sq. Mm (Clamped With 1Mm Thick Saddle) M 2130.0 29 0.0 5.5.2 7.8.2 Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) M 277.0 29 0.0 5.5.3 7.8.3 Above 95 Sq. Mm And Upto 185 Sq. Mm (Clamped With 25/40X3mm Ms Flat Clamp) M 65.0 29 0.0 5.5.4 7.8.4 Above 185 Sq. Mm And Upto 400 Sq. Mm (Clamped With 40X3mm Ms Flat Clamp) M 45.0 29 0.0 , 7.9 6. Mv Cable Jointing & End Termination , 9.1.32 , 9.1.33 , 9.1.34 , 9.1.22 , 9.1.23 , 9.1.30 7. Ht Cable Jointing & End Termination , 10.4.4 300 Sq. Mm Each 4.0 29 0.0 8. Miscellaneous Civil Items , 8.1.1 14.14.1 100 Mm Dia M 50.0 29 0.0 8.1.2 14.14.2 150 Mm Dia M 140.0 29 0.0 8.1.3 14.14.4 300 Mm Dia M 250.0 29 0.0 8.1.4 14.16.3 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Il Complete With Fitting And Cutting, Jointing Etc.Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc. , Complete As Required 120Mm Dia(Od-120Mm &Id-103Mm Nominal) M 50.0 29 0.0 9. Solar , Lmr 10. Ht Panel, Ht Cable, Transformer And Dg , Lmr 11. Lt Panels , Lmr 500/5A 15Va Class 1 Resin Cast Ct - 2 Set 200/5A 15Va Class 1 Resin Cast Ct For Connection To Apfc Panel Including Necessary Size Connecting Cable - 1 Set Outgoing. 320A Fp 25Ka Mccb With Microprocessor Release With Adjustable Ol, Sc Protection And Ef Protection - 1No. 200A Fp 25Ka Mccb With Thermal Magnetic Release With Adjustable Ol, Sc Protection - 3No. 160A Fp 25Ka Mccb With Thermal Magnetic Release With Adjustable Ol, Sc Protection - 1 No. 100A Fp 25Ka Mccb With Thermal Magnetic Release With Adjustable Ol, Sc Protection - 6 No. 250A Fp 25Ka Isolator With Front Operated Handle - 1No. 12 No 3 Phase Digital Multi Function Meter To Read V, A, F, Kw, Kwh With Acc Class 1 Including Respective Feeder Rating Ct On The Incoming And Outgoing Feeders , Lmr 12. Ups , Lmr 13. Lt Cables Supply Of The Following Size 1.1Kv Grade Xlpe Insulated Pvc Sheathed, Armoured Aluminium Conductor Power Cable Confirming To Is 7098 (Part 1) Ammended Upto Date. , Lmr 14. Light Fittings & Fans , Lmr 15. External Lighting , 90.15.3.1 , 90.15.3.2 , 90.15.4.2 16. Lightning Protection System , Lmr 17. Miscellaneous , Lmr 18. Rmu & Ht Cable Laying , Lmr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Elv Sl. No Dsr No. Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) 1. Fire Alarm System , 4.6.2 , 14.16.1 , Lmr 2. Public Address System , 14.16.1 3. Cctv System , 1.21.2 , 1.53.1 , 4.6.2 , 14.16.12 , Lmr 4. Data System , 1.21.2 , 1.21.3 , 1.27.1 , 1.53.1 , 1.53.2 , 4.6.2 , Lmr 5. Telephone System , 1.18.2 , 1.21.2 , 1.24.6 , 1.27.1 , 4.6.2 , 14.16.1 , Lmr 6.Tv System , 1.21.2 , 1.21.3 , 1.24.7 , 1.27.1 , Lmr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Fire Fighting Works Item No. Item Code Item Description Qty Unit Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , 18.1.9 , 18.2.9 , 18.3.3 , 18.4.2 , 18.5.1 , 18.6.2 , 18.7.1 , 18.7.2 , 18.7.3 , 18.7.4 , 18.7.5 , 18.7.6 , 18.7.7 , 18.7.8 , 18.9.2 , 18.10.2 , 18.11.4 , 18.11.5 , 18.11.6 , 18.12.7 , 18.14.4 , 18.14.5 , 18.14.7 , 18.15.1 , 18.15.3 , 18.16.2 , 18.17.1 , 18.18.2 , 18.19.2 , 18.21.1 , 18.21.2 , 18.22 , 18.23.1 , 18.24.3 , 18.25.2 , 18.29 , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Hvac Works Item No. Item Code Item Description Qty Unit Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr A 36 Hp Nos 1.0 29 0.0 , 16.12.1 A 16.12.1.1 24G Sq Mts 150.0 29 0.0 B 16.12.1.2 22G Sq Mts 35.0 29 0.0 , 16.12.2 A 16.12.2.1 24G Sq Mts 30.0 29 0.0 B 16.12.2.2 22G Sq Mts 15.0 29 0.0 , 16.13 , 16.17 , 16.15 , Mr A 150 Mm Dia Rmts 10.0 29 0.0 B 200 Mm Dia Rmts 10.0 29 0.0 C 250 Mm Dia Rmts 20.0 29 0.0 , 16.20.1 16.20.2 Supplying, Fixing, Testing And Commissioning Of Fire Dampers In Supply Air Duct/ Main Branch And Return Air Path As And Where Required Of Required Sizes I/C Control Wiring, The Damper Shall Be Motorized And Spring Return So As To Close The Damper In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The Damper Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. Actuator Nos 5.0 29 0.0 , Mr A 200 Cfm Nos 2.0 29 0.0 B 150 Cfm Nos 3.0 29 0.0 C 100 Cfm Nos 1.0 29 0.0 D 300 Cfm Nos 2.0 29 0.0 Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Lift Works Item No. Item Code Item Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Signage Item No Dsr Code Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis , Dsr Analysis Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Mgps Sn. Item Description Unit Quantity Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr Solid Drawn, Seamless, Deoxidised, Non- Arsenical, Half Hard, Tempered And Degreased Copper Pipes As Per Tender Technical Specifications 0.0 , Line Isolation Valves , Ot Pendants (Anesthetist & Surgeon) , Mr Total Amount (Excl. Gst) 0.0 , Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder Boq-Stp Item No. Item Code Item Description Unit Qty Rate In Figs. (Rs.) (Excl.Gst) Rate In Words (Rs.) (Excl.Gst) Amount (Rs.) (Excl.Gst) , Mr Total Amount (Excl. Gst) 0.0 , Financial Bid (Part -B)-O&M And Camc For Stp & Etp Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of The Bidder: Part-B1 - O&M S.No. Project Component Cost In Inr (Excl. Gst) , Operation & Maintenance Of Entire System For A Minimum Period Of 9 Years Including Consumables And Manpower After Completion Of 12 Months Of Operation. , 1St Year , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year , 6Th Year , 7Th Year , 8Th Year , 9Th Year Total (Part-B1) (Excl. Gst) 0.0 , Part-B2 - Camc S.No. Project Component Cost In Inr (Excl. Gst) , Camc For 7 Years After Completion Of Dlp , 1St Year , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year , 6Th Year , 7Th Year Total (Part-B2) (Excl. Gst) 0.0 , Total For Part B (Part-B1+Part-B2) (Excl. Gst) 0.0 The Rates Quoted At Part B Will Be Not Be Considered For Determining L1 Financial Bid (Part -B) For Mgps Establishment Of Institute For Organ And Tissue Transplant, Chevayur, Kozhikode - Construction Of Dermatology Hospital And Its Allied Facilities (Tender No. Hites/Ids/Iot-Kzd-Drmtgy/25/26) Name Of Bidder: Part-B - O&M For Mgps , Providing Comprehensive Maintainenace Contract For Medical Gas Pipeline System (Mgps) On Successful Completion Of Warranty , 1St Year , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year Total (Part-B) (Excl. Gst) 0.0 The Rates Quoted At Part B Will Be Not Be Considered For Determining L1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
46.
Tourism #10881944 Technical Bid
Tender for Furniture Supplying Of Bed Headboard Paneling Made In 19Mm Marine Plywood With 0.1Mm Laminate Finish From Outside And In Middle Bed Headboard With Foam 32D And Fabric As Chosen For The Back Restoration Size: 14Ft X 4Ft , Supplying Of Designer Molding Above The Bed Headboard With Wooden Patti 2 X 1 With Designer Patti With Deco Paint Finish. Size: 14Ft X 1Ft With Concealed Coved Light On The Headboard . , Supplying Of Double Bed Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand. Size: 78 X 72 X 16 , Supplying Of Bed Side Table Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand. Size: 18 X 16 X 24 , Supplying Of Non Woven Wallpaper Above The Bed Headboard Including Installation Charges. Size: 11Ft X 4Ft , Supplying Of Dressing Unit Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand With 4Mm Mirror Company Saint Gobin With Appropriate Handles And Fixtures. Size: 36 X 90 X 26 , Supplying Of Dressing Unit Stool Made In Sal Wood Frame With High Density Foam And Fabric As Per The Chosen. Size: 20 X 24 X 18 , Supplying Of Wardrobe Made In 19Mm Marine Gurgen Plywood With 0.1Mm Fabric Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers And Shefls With Access Rod For Hanging Cloths Wardobe Size: 4.6Ft X 7Ft X 24 , Supplying Of Luggage Rack Made In 19Mm Marine Gurgen Plywood With Teakwood Frame Size 2 X 1.5 With 18Mm Stone Marble Finish With Edged Polished On Top. Size: 3.10Ft X 2Ft X 22 , Supplying Of Tv Unit Made In 19Mm Marine Gurgen Plywood With 0.1Mm Glossy Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers. Size: 6.7Ft X 2Ft X 24 , Supplying Of Working Desk Made In 19Mm Marine Gurgen Plywood With 0.1Mm Glossy Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers. Size: 3Ft X 2Ft X 24 , Supplying Of Working Desk Chair Made In Teakwood Frame With High Density Foam And Fabric As Per Chosen With Melamine Polish. , Supplying Of Curtain Pelmet Made In 16Mm Marine Plywood With Laminate Finish With Double Curtain Tracks. Size: 11.4Ft X 2Ft , Curtain Fabric Main (80% Blackout With 100% Polyster Material Easy To Maintain Wash) Brand - Ddecor Size: 11.4Ft X 8.5Ft , Curtain Fabric Sheer (100% Polyster 54 Width Light Weight Easy To Maintain Wash) Brand - Ddecor Size: 11.4Ft X 8.5Ft , Curtain Installation And Stitching Charges For Window Size: 11.4Ft X 8.5Ft , False Ceiling Made In Gyproc Borad With Required Metal Support / Chanel Patti / Rafter Patti / L Patti (Isi Marked ) Etc. All The Materials Used For The Above Item Shall Confirm To The Latest Relevant Is Standards. Size: Size: 22.5Ft X 11.6Ft Including Cutiing Charges For Light Fixtures And Ac Drains , Supplyng Of Sofa Arm Chair Made In Sal Wood Frame With High Density Foam And Fabric Suede Type 400Gsm Fabric As Per The Selection. Size: 30 X 18 X 20 , Supplying Of Center Table Made In Teakwood Frame With Melamine Polish With Top 12Mm Clear Glass. Size: 3Ft X 2Ft , Bathroom Fixtures Providing & Installtion Of Sanitory Ware - Counter Top Basin Brand - Hindware/ Kohler/ Cera / Parryware / Jaguar Or Equilant Other Brand With Bottle Trap 300Mm And Polished Chrome. Model No. K-7314In-Cp , Sanitory Counter - Carcass- Made Of 50Mmx 50Mm Gi Tube Coverd With Marine Plywood / Acrylic Limaniate / Top Made Of Indian Stone - Granite / Jaislermer/ Makrana Etc Edges Witll Diamond Polished With Blunt Edge Profile / Led Lighting / Dustbin & Tissue Throw Cut Provisioned , Western Styled Toilet Seat - Make Of Cera/ Hindware/ Jaguar Etc , With Health Faucet, Tab, Tissue Holder / Storage Tank Etc With Installation , False Ceiling - Made Of Grid Pattern Pvc Multiwall Celing , Supplying Of Toilet Door Made In Teakwood Frame With 20Mm Blockboard With Laminate Finish With Appropriate Hanges And Handles- With 304 Ss Accessories - Auto Door Closer , Mirror -6Mm Clear Mirror Float Glass All Edge Polished Height - 3.5 Ft , Width As Per Requirement - Irrespetive Of Small Or Big Sizes Pof Area Mounted On 16Mm Thick Marine Plywood , Exhuast For Urinal Area And Basin Area 4 Dia Pvc Pipe Ducting / Inline Fan Etc , Supplying Of Square Shower Head With Shower Arm In Polished Chrome - Model No. K226451n-Cp - Brand - Kohler , Supplyin Of Square Hand Shower Without Hose In Polished Chrome - Model No. K970091n-Cp , Supplying Of Bath Spouts With Diverter In Polished Chrome - Model No. K-2351In-Cp , Supplying Of Shower Enclosure With Toughned Glass And Hanges And Fittings With Rubber - Model No. K-704699In-Shp (Id2p-S In) Upto 3000 Mm Running Length , Supplying Of Angle Valve And Polished Chrome - Model No. K-23515In-4-Cp , Supplying Of 2 Way Bib Tap In Polished Chrome - Model No. K-20075In-4-Cp , Supplying Of Click Drain Big Cap In Polished Chrome - Model No. K-7120In-Cp , Supplying Of Towel Shelf In Polished Chrome - Model No. K-25066In-Cp , Supplying Of Square Tissue Holder With Cover In Polished Chrome - Model No. K-25071In-Cp , Supplying Of Towel Ring In Polished Chrome - Model No. K-5631In-Cp , Supplying Of Tissue Holder In Polished Chrome - Model No. K-5632In-Cp , Supplying Of Soap Dish In Polished Chrome -Model No. K-5634In-Cp , Supplying Of Tumbler Holder In Polished Chrome - Model No. K-5637In-Cp , Supplying Of 6L Step Can In Stainless Still Dustbin _ Model No. K-17531T-St , Bath Of Bath Grip In Polished Chrome - Model No. K-10701D-Cp , Supplying Of Outdoor Furniture Chairs Made In Aluminum 18 Gauge Pipe With Plastic Cane With High Density Foam Using Outdoor Sunbrella Fabric All Weather Proof As Per The Design Selected. Size: 30 X 20 X 18 , Supplying Of Outdoor Furniture Center Table Made In Aluminum 18 Gauge Pipe With Plastic Cane As Per The Design Selected. Size: 3Ft X 2Ft , False Ceiling Made In Pvc Sheet For Outdoor Use Using Gyproc Borad With Required Metal Support / Chanel Patti / Rafter Patti / L Patti (Isi Marked ) Etc. All The Materials Used For The Above Item Shall Confirm To The Latest Relevant Is Standards Including Cutiing Charges For Light Fixtures And Ac Drains , Designing Of Floor Plan For The Layout Purpose Including 3D And 2D With Floor Plans False Ceiling, Tiling, Furniture, Plumbing And Electrical Designing. , Designing Of 3D With Colours Scheme And Cordination With Execution Planning And Statistics Including Space Management And Consulting Charges , Electrical Items 25Mm Condut Pipe - Brand Sudhakar , 25 Mm Junction Box - Brand Sudhakar , 25 Mm Bend - Brand Sudhakar , Insulation Tape - Sudhakar , 1 Module Plate Metal Box - Brand Legrand Lyncus , 2 Module Plate Metal Box - Brand Legrand Lyncus , 3 Module Plate Metal - Brand Legrand Lyncus , 4 Module Plate Metal Box - Brand Legrand Lyncus , 6 Module Plate Metal Box - Brand Legrand Lyncus , 8 Module Plate Metal Box - Brand Legrand Lyncus , 1 Sqmm Wire - Brand Polycab , 1.5 Sqmm Wire - Brand Polycab , 2.5 Sqmm Wire - Brand Polycab , 4 Sqmm Wire - Brand Polycab , Cat 6 Cable - Brand D Link , 1 Module Plate - Brand Legrand Lyncus , 2 Module Plate - Brand Legrand Lyncus , 3 Module Plate - Brand Legrand Lyncus , 4 Module Plate - Brand Legrand Lyncus , 6 Module Plate - Brand Legrand Lyncus , 8 Module Plate - Brand Legrand Lyncus , 5 Amps Switch - Brand Legrand Lyncus , 5 Amps Sockets - Brand Legrand Lyncus , 15 Amps Switch - Brand Legrand Lyncus , 15 Amps Socket - Brand Legrand Lyncus , Telephone Socket - Brand Legrand Lyncus , Outside Room - Bell Push Switch - Brand Legrand Lyncus , Room - Regulator - Brand Legrand Lyncus , Room - Main Switch Key Tag - Brand Legrand Lyncus , Room - Fan 48 Inches - Orient,Havells, Crompton , Balcony - Fan 24 Inches - Orient,Havells, Crompton , Bathroom - Celing Exhaust - Brand Orient,Havells, Crompton , Bathroom - Geyser 5L - Brand Crompton, Recoilt , Room - 12 Watt Cob - Brand Panasonic, Wipro, Philips , Bathroom And Wardrobe - 7 Watt Cob - Brand Panasonic, Wipro, Philips , Room - Strip Light 24O Led , Balcony - 12 Watt Cylinder , Room - 3 Module Laser , Balcony - Bollard , Room - Hanging Light , Bathroom And Dressing - Picture Light , Bed Side - Wall Lamp , Corridor - Surface Panel - Brand Panasonic, Wipro, Philips , Wardrobe - Cabinet Light - Brand Wipro, Ledure , Wardrobe - Wardrobe Sensor- Brand Sensonova , Bathroom - Bathroom Sensor - Brand Sensonova , Room - Bell , Room - Foot Lamp (Indoor) , Balcony - Foot Lamp (Outdoor) , Electrical - Wiring And Cabling, Switches And Sockets Installation, Lighting Fixtures And Rectification, Concealed Work Conduit Laying ,Final Inspection , Room - Tv (43 Inches) , Room - Fridge , Room - Kettle , Bathroom - Hair Driyer , Bathroom - Hanging Telephone , Room - Telephone , Room -Digital Locker , Door - Door Lock Rfid - Brand Yale, One Touch, Goderej , Corridor - 25 Mm Conduit (1.2 Mm ) 3 Mtr - Brand Sudhakar , Corridor - 1 Sqmm Multistand - Brand Polycab , Corridor - Surface Panel 15 Watt - Brand Panasonic, Wipro, Philips , Corridor - 4 Module Plate - Brand Legrand , Corridor - 6 Amps Switch - Brand Legrand , Corridor - 4 Module Metal Box - Brand Legrand , Labour Charges For Electrical Work , 25 Mm Conduit (1.2 Mm ) 3 Mtr- Brand - Sudhakar- For Corridor , 25 Mm Band - Brand - Sudhakar , 25 Mm J Box - Brand - Sudhakar , 2.5Sq Mm Wire - Brand - Polycab , 1 Sqmm Multistand - Brand Polycab For Corridor , Surface Panel 15 Watt - Brand Panasonic, Wipro, Philips , Mcb Box - Brand Legrand , Mcb 32 annual periodical maintenance 3 Pole - Brand Legrand , Mcb 16/32 - Brand Legrand , 4 Module Plate - Brand Legrand , 6 Amps Switch - Brand Legrand , 4 Module Metal Box , Erting , Civil Works Breaking Of Toilet Wall And Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block - D3,D8,D7,D5,D6,D1,D4 , Breaking Of Waterproofing In Sunken Area For Provision Of Plumbing Pipes, Shifting The Debris, And Disposing Off The Same Including Cost Of Transportation, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Crystaline Waterproofing For Toilet Sunk And Wall Upto 1Mtr Height, Including Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Filling Sunken Slab With Hard Laterite Or Rubble Stone Upto 200Mm Ht, With 1:3 Cement Mortar Mixed With Waterproofing Compound, Including Material And Labour Complete. Block D2,D8,D7,D5,D6,D1,D4 , Providing And Applying Smooth Waterproof Cement Plaster 18Mm Thich In Cement Mortar (1:3) To Reinforced Cement Concrete And Masonary Surfaces Mixed With Waterproofing Compound, Including Smooth Patra Finish, With Material And Labour And Material Complete. Block D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Single Coat Plaster For Toilet Walls Upto 12Mm Thick In (1:4) Cement Mortar, Including Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing In Position Readymade Tiles Of Nitco,Somany, Kajaria Make Of Approved Colour And Sizein Dado/Wall As Per Design, Including Cutting To Proper Size, Fixing To Level In Cement Paste, Filling The Joints With Matching Colour, With Material And Labour Complete (Basic Rate = Rs 800/Sq.Mtr) Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Granite Counter For Wash Basin In Toilet, Including Full Moulding For Edges, With Material And Labour Complete.(Basic Granite Rate = Rs. 200/Sq.Ft) Block D2,D3,D7,D5,D6,D1,D4 , Breaking Of Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Coping Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D8,D7,D5,D6 , Providing And Laying In Position Readymade Floor Tile For Flooring Of (Size 2*2/4*2)Size Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D32,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Balcony Flooring Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Balcony Coping Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D8,D7,D5,D6 , Breaking Of Concrete Sopo In Balcony, Shifting The Debris And Disposing Off The Same Including Transportation Construction Block D2,D3,D1,D4 , Breaking Of Old Damaged Plaster From Internal Ceiling And Wall. Block D3,D8,D7,D6,D1,D4 , Providing And Fixing Single Coat Plaster For Ceiling And Walls Upto 12Mm Thickness, In (1:4) Cement Mortar, Including Material And Labour Complete. Block D8,D7,D6,D1,D4 , Breaking Of Passage Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Tile From Pardi Top,Wall Tile In Staircase, Staircase Step, Ground Floor Passage Floor,External Steps,Duct And Store Room Floor,External Step For Block 1 & 4 , Breaking Of Passage Floor Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete.Ground Floor Passage Flooring, Duct And Store, Staircase Skirting , Providing And Laying In Position Readymade Floor Tile For Flooring Of (Size 2*2/4*2)Size Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. First Floor Passage Flooring, Tile From Pardi Top, Ground Floor Passage Floor, Duct And Store Room Floor , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. First Floor Passage Flooring, Ground Floor Passage Flooring, Duct And Store, Staircase Skirting , Providing And Laying In Position Jet Black Granite In, Steps Tread As Directed To Proper Levels And Lines Including Setting In Cement Mortar (1:3) 25Mm Thk And Joined With Cement Slurry, With Material And Labour Complete. Staircase Step, External Step , Painting Work Application Of 1 Coat Damp Proof Primer And 2 Coat Apex Ultima Paint For Ceiling And Walls, Including Cost Of Scaffolding, With Material And Labour Complete. , Application Of 2 Coat Cement Based Putty, 1 Coat Internal Primer And 2 Coat Premium Emulssion Paint For Ceiling And Walls, Including Material Nad Labour Complete. Room No. D5,D6,D7,D8,D1,D4,D2,D3 , Application Of 1 Coat Primer And 2 Coat Ace Emulsion For Ceiling And Walls Of Staircase And Passage, Including Material And Labour Complete. , Application Of Oil Paint For Railing And Grill, Including Material And Labour Complete. , Plumbing Work Providing And Fixing Upvc Pipes For External Work Confirming To (Astral Flow Guard/Supreme ) Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fitting S Including Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Cheses And Testing 11/2 Pipe Ing Upvc Pipes For External Work Confirming (Astral Flow Guard/Supreme ) Having Thermal Stability For Cold Water Supply Including All Upuc Plain Elbow Tee And Fitting S Including Jointing Of Pipes And Fittings With One Step Upvc Solvent Cement And The Cost And Testing 11/2 Pipe , Providing And Fixing Upvc Pipes For External Work Confirming To (Astral Flow Guard/Supreme ) Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fitting S Including Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Cheses And Testing 11/2 Pipe Ing Upvc Pipes For External Work Confirming (Astral Flow Guard/Supreme ) Having Thermal Stability For Cold Water Supply Including All Upuc Plain Elbow Tee And Fitting S Including Jointing Of Pipes And Fittings With One Step Upvc Solvent Cement And The Cost And Testing 2 Pipe , Providing And Fixing S.W.R Soil And Waste Pipes. Isi Marking/ Rubber Ring Joints All Special Such As Bends,Tee, Reducers Etc.4 Pipe , Providing And Fixing S.W.R Soil And Waste Pipes. Isi Marking/ Rubber Ring Joints All Special Such As Bends,Tee, Reducers Etc.21/2 Pipe , Providing And Fixing Pvc Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 6 Pipe , Providing And Fixing Pvc Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 11/2 Pipe , Providing And Fixing Pvc Rain Water Pipes Including All Fitting Such As Bends ,Tee, Reducers Support Etc 4 Pipe , Providing And Fixing Pvc Ac Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 3/4 Pipe , Providing And Fixing Pvc Floor Trap 110×75 Mm Self Cleansing With Or Without Went Arm Inlet Receiving Cap For Inlet Dia 50And 40 Mm Complete Including Cutting And Marking Good Wall And Floor , Providing And Constricting With First Class Bricks In Cement Mortar 23 Cm Wall Of Inspection Chamber Laid Over A Bed Of Cement Concrete Inside Plastering Thick With Cement Morter Finished With Floating Coat 24×24 Size Including Providing C.I Man Hole Cover With Frame , Providing And Constricting With First Class Bricks In Cement Mortar 23 Cm Wall Of Inspection Chamber Laid Over A Bed Of Cement Concrete Inside Plastering Thick With Cement Morter Finished With Floating Coat 18×18 Size Including Providing C.I Man Hole Cover With Frame , Providing And Fixing Brass Ball Valves Having Pressure Rating Of 20 Bar Make Molotov Or Equivalent 2 Size , Providing And Fixing Brass Ball Valves Having Pressure Rating Of 20 Bar Make Molotov Or Equivalent 11/2 Size , Providing And Fixing Pvc Rigid Water Storage Tank Of 2000 Ltr. Of Sintex And Shakti, Plasto, Supreme Make At All Heights And Level ,,Make Including All Necessary Fixing , Wall Mounted P Trap Water Closet Providing And Fixing In Position First Quality European Type Standard Wall Mounted Model No. Sls-Wht 6953 Including Heavy Solid Plastic Seat Cover With Rubber Buffer Flap Cover , Providing And Fixing Gabriet Or Equivalent Type Plastic Concealed Cistern With Dual Flush 6/3 Ltr Including Water Supply Connection Code No.110.121.00.1 , Concealed Type Flush Control Plate Of Gabriel Make Model No .115.045.21.3 , Providing And Fixing In Position White Under Counter Wash Basin Of Jaqwar Make Model No Fnswht-.40701 Or Equivalent Of Approved Quality With Jaquar Make Series Waste Coupling Model No. 709 Bottle Trap Model No. Acd7696-300×190 Connection Pipes , Providing And Fixing Two Way Bib Cock Model No. Opp-Chr-15041 Of Jaqwar , Providing And Fixing Health Faucet Of Jaqwar Model No. 573 , Providing And Fixing Basin Mixer Model No. Opp-150053 Of Jaqwar , Providing And Fixing Angel Stop Cock Of Jaqwar. Make Continental Seris Model No. 053 Kn , Providing And Fixing Single Lever Diverter Exposed Parts Kit Of Jaqwar Make Opel Prime Series Model No.Opp-15079Nkpm , Providing And Fixing Concealed Body For Single Lever Diverter Of Jaqwar Make Model No.Ald-Chr-079N , Providing And Fixing Overhead Shower Shower Arm Model No.Shp479l450 Ohs-Chr-1603 , Providing And Fixing Bathtub Spout And Hand Shower Of Jaqwar Make Model No.Spj-Chr-15463 , Providing And Fixing Concealed Stop Cock Of Jaqwar Make Model No. 089 ,083 , Providing And Fixing Nahni Trap S.S Jally 6×6 , Providing And Fixing Pressure Pump 1.5 Kg Of Make V Guard , Providing And Fixing Of Storage Heater With Heating Capacity Of 10 Ltr Make Recold Eterno Make Or Equivalent With Necessary Inlet And Outlet With Flexible Pipes , Roofing Removel Of Existing Battens, Asbestos Sheets, Battens, Mangalore Tiles And Fabricated Structure With Acp Sheets , Fabrication Of 2Ft X 2Ft Grid Over The Existing Roof Slab, Iko Cambridge Shingle (30 Year Warranty), Membrane (Asian Paints) 3 Mms, Bitumen Primer, Ridge, 16Mm Fiber Cement Board, Aluminum Drip Edge, Installation, Transport, Handling & Gas , Facia (8Inches) , Upvc Gutters 6Inches
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
47.
Defence #10861312 AOC
Tender For Repair/ Maintenance Of Ht Cables, Switch Gears And Relays Incl Connected Items Under Ge (W) Colaba.; 1 Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamberof HT 11KV, panel boardand carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge.(Note: spare parts shall be measured & paid seperately.) :-(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B)and HTtape and test with High Voltage(DC)and meggering before and after high voltage test complete.(ii) Inspecting/cleaning/overhauling of CT/PT chamberby checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CTs and insulatorsand HT Tape.(iii) Inspecting/cleaning/overhauling meteringchamberby checking ofentire wiring system, all meters, selector switches, control fuses and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system. 2 Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 3 Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare partssuitable for - VCB 11 KV , 630/800 Amps indoor type of Make Schnieder(PIX -MV)/ABB(VD4) /CG/AREVA(VMX) all as specified and directed by Engineer-in-Charge. 4 Isolating Contacts flat type 5 Vaccum InterupterVG2 6 Insulating Rod 7 Closing coil 110V /24V DC 8 Tripping Coil 110V /24V DC 9 Spring Charging Motor 110V-230V AC/DC 10 Breaker Auxiliary Switch 6NO +6NC 11 Motor Cut-off switch 12 Main Drive Shaft assembly 13 Trip Fork Linkage Assembly 14 Rachet Wheel 15 Pin for Rachet 16 Handle Block Assembly 17 Closing coilassembly without coil 18 Trip coilassembly without coil 19 Motor cutt offLever assembly 20 Trip Proper support assembly 21 Release lever 22 Pin for Release lever 23 Auxiary switch drive Assembly 24 Charging Pawl 25 Buffer for Spring 26 Over Rid Stop 27 Over Rid Stop Pin 28 24 Pin Plu and Socket Assembly 29 Bus Bar Spout Insulator with CC parts for R Phase 30 Bus Bar Spout Insulator with CCparts for Y Phase 31 Bus Bar Spout Insulator with CC parts for B Phase 32 Circuit Spout Insulator with CC Parts 33 3Phase Spout Insulator assembly Bus bar /Circuit side. 34 Half Collar (Pair) 35 Raising and lowering Handle 36 TNC Switch,16Amps Recom 37 Ammeter,digital type,DM3110 Schneider 38 Voltmeter,digital type DM3210 Schneider 39 Multifunction meter digital typeEM6400NG Schneider 40 Indicating Lamps 24/110V DC LED type 41 Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts ACand replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately) 42 Material and labour for painting of HT VCBcapacity 250/350MVA,11KV, 400/630/800Amps, with onecoat of synthetic enamel paint over a coat ofred oxide primerafter cleaning, scraping, and filling ofcavitiesfor out side surface and in side surfaceof VCB and writing the details such as MES No/ SM No etc on the new metallic plate of size 30x15cm and fixng the metallic plate firmy on VCBall as specified and as directed by Engineer-in-charge. 43 S&F, testing commissioning ofcurrent transformer 50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec for 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps, panel board complete all as directed and specified by Engineer-in-Charge. 44 T&P for Testing of primary injection by artificialloadthroughCT’s, on each multiple settingofovercurrent & earth fault relay, testing polarities, ammeter and selectorswitchandasdirected by Engineer-in-Charge. 45 T&P for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete. 46 Repair/Overhauling Indoor type, 11 KV, SF 6, RMU Panel and carrying with following and all as specified and directed by engineer in Charge.Note :- (i) Including fixing ofspare parts to function RMU smoothly and rate to be included.Notes :-Spare parts and SF6 Gas will be measured and paid separatly. (i) Inspecting/overhauling of Manual/motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, Small Cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply multi grease lubricant to function smoothly.(ii)Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii)Inspecting / overhauling /cleaning and inspecting insulators, Gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Inspecting of Gas SF6 leakage and Re filling SF6 gas as required and all as directed.(v) Overhauling/testing of Metering Panel with PT(vi) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete.(vii) Cleaning all busbar by rubbing and by CRC liquid cleaner.(viii)Spraying two coat of anti track paint on CTs.(ix) Applying insulating boots for busbar and cables. (x) Supply and fixing all missing nut bolts for panels. 47 S&F 11 KV, SF 6,RMU Panel Spring Charging Motor, with complete mechanisim 230/110/24 Volts of existing make. 48 S&F 11 KV, SF 6,RMU Panel SF 6 Gas filling up to the indication mark complete all as specified and as directed. 49 Repair/ MaintenanceBattery Charger Circuit 240 V AC to110 V DC 20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed. 50 Repair/ MaintenanceDC to DC Converter 110 V DC to 24 Volt dc20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed 51 S&F battery SMF EP 100-12 (12V/100AH) complete all as specified and as directed 52 Dismantling old burnt Heaters and Supply Fixing Space Heater 80 Watt capacitysuitable for VCB,s /OCB in existing panel including hard ware,wiringand all as directed. 53 T&P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 54 T&P for route tracing ofHT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 55 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 56 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240 sqmm to 300 sqmm all as specified. 57 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 58 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240sqmm to 300 sqmm all as specified. 59 Supply, Installation, testing ON LOAD & commissioning of Compact motor protection relay flush mounting with display MM-10 with 110-240V AC/DC aux supply, having following protections with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system making good to the disturbed surface all as specified and directed.(a) Thermal over load and short circuit . (b) Earth fault and phase loss, unbalance, phase reversal.(c) Prolong starting, locked rotor and last trip data recording. 60 Supply, Installation, testing & commissioning of Under Over Voltage relay single phase system voltage 20-110 Volt AC/DC with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system including making to the disturbed surface all as specified and directed. 61 Material and labour for loading into truck of old OCB/VCB with the help of Crain and shifting from site to store/ substation premises and unloading complete all as specified and directed. 62 Material and labour Disconnecting, dismantling & restablising the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 63 Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out completein soft/loose soil all as specified. 64 All as perabove item No.63.00 above but in hard/dense soil. 65 Excavationin trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in soft disintegrated rocks/road cutting/RCC/PCC complete all as specified and directed. 66 Supply and providing sand/stone dust for sand cushioning for cable protection orfilling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thicknesswill be measured. 67 Supply and providingunreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) ofsizes Class HVPtype I with peak, flat size 300x180x40 mm putting adjecent to each other as specified. 68 Supply and laying tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed. 69 Returning,filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified. 70 Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil 71 Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed. 72 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 240 sq. mm X 3 core all as specified and as directed. 73 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed. 74 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm X 3 core all as specified and as directed. 75 Manufacturing, supplying and fixing at various sub stations for SOP (Standard Operating Procedure) for VCB/ RMU Operation on farme board of size 600 mm x 900mm having fully covered by suitable plain glass as approved . Letter,symbols, MES Logo ,borders etc.on A-1 Size paper all as required colour scheme in all respects as per direction of Engineer-in-charge. 76 T&P for fault finding, confirmation and route tracing on LT cables of any size and any length with fault detective machine by thumping method and suitable high voltage and all as and directed by Engineer-in-charge. 77 Material & labour for cable jointing kit, in repair, for LT 1.1 KV grade cable for straight through joint M-Seal type for underground PVC/XLPE armoured heavy duty cable aluminum conductor of size3.5/4 core 50 Sqmmcomplete including testing & commissioning complete all as specified and directed. Make: XICON/Raychem/3M/Mahindra and Mahindra. 78 All as per aboveitem No 77.00 herein before but cable 3.5 core 70 Sq mm 79 All as per aboveitem No 77.00 herein before but cable 3.5 core 95 Sq mm 80 All as per aboveitem No 77.00 herein before but cable 3.5 core 120 Sq mm 81 All as per aboveitem No 77.00 herein before but cable 3.5 core 185 Sq mm 82 All as per aboveitem No 77.00 herein before but cable 3.5 core 240 Sq mm 83 Material & Labourfor repairs/ Overhauling/Servicing to ExistingLT electric panels by takingshut down from appropiate authority includingT&P for Attending Faults/Trippings and rectifieng /repairingthe faults in HT/LT Panels Boards/Capacitor Panels Boaeds/ MCCBs/ACBs /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut boltsand all as specified and directed by Engineer-In-Charge. (i)Tightning the loose connectionsand cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as pproved colourandtesting the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed .(Note : MCCB,ACB, measured and paidseparately under relevant items of this schedule.) 84 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 240 Sqmm to 300 Sqmm x 3.5 core complete all as specified and directed by Engr-in-charge. 85 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 240Sqmm x 3.5 corecomplete all as specified and directed by Engr-in-charge. 86 Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhaulingof spring drive mechanism, coil, auxiliary switch includingsetting of over loadcoil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspectingmale and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective positionandtesting complete all as specified and directed by Engineer-in-Charge. 87 Dismantling of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare partssuitable for -ACB 415V , 630 to 1200Amps Amps indoor type of Make ; Havells/ Schneider/IndoAsian/HPL/Legrand/C&S all as specified and directed by Engineer-in-Charge. 88 Shunt Trip Device 89 Closing coil assembly 90 Mismatch Prevention Device 91 Moving contacts assembly 92 Fixed Contact assembly 93 Auxiliary Switch 94 Arc chut with hardware 95 Current Transformers 630A/5A. 96 Current Transformers 800A/5A 97 Current Transformers 1200A/5A 98 Dismantlingof old damaged Meters and Supply & fixDigital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:AE/MECO/ Elmeasure. 99 Dismantlingof old damaged MetersSupply & fixing Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type andall as specified and directed. Make:AE/MECO/ Elmeasure. 100 Dismantling of old damaged halogen fitting Supply & fixing in repairs 500 watt Incandescent/ GLS lamp halogen Lamps with holder with aluminum cover 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 101 S&F of Room Heater 1000 Watt coil type in substation to avoid moisture in HT installation room complete all as specified and directed by Engr-in-charge. 102 Dismantling of old damaged Lamps and Supply & fixing in repairs 200 watt Incandescent/ GLS lamp 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 103 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel as required for retrofit after wiring work complete all as specified & directed. 104 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel,SMARTCOMN EMS Energy Management System software with multiple features suitable for minimum 10 meters at existing dashboard/ computer and shall capture and provide following data for 12 months peroid:1) 30 min instantaneous data from all the meters for seven parameters- cumulative Energy, Power, Current, Voltage, Power factor and frequency. 2) Multiple combination of device and parameters for analysis and monthly and quaterly billing survey dattion a for cumulative energy and max demand.3) Specific Energy Consumption (SEC) Report and assess to features defined by user levels.4) Monitor ON, OFF, TRIP, Ready to close status of circuit breaker through E&As UNCO Module with on premise solution. 5) Provision for Breaker ON & TRIP counter, Last 20 trips date & time6) Email and SMS notification & Excel reports with charts. 105 M&L for Maint of MQTT GPRS Converter Outdoor (LoRa) Long Range Communication Accumulator suitable for communicating with multifunctional digital Meter with LoRa communication protocol and the data transfer to the software complete all as required on existing ground position as specified and directed. 106 M&L for Maintand recharge topup for 12 months peroidof 4G/5G Router all asrequired as on existing ground position including necessary data cable (low impedance ) suitable to existing ground position including necessary data cable (low impedance) suitable to transmit data of energy meter port and CAT-6 (Patch Cord) all as directed by Engr-in-Charge. 107 M & L and fabrication work with Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and diredted by Engr-in-charge. 108 M&L electrical earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly inground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level, connected toGI earth strip 32mm x 6mmearth leadby means of bolts,nuts and washers of galvanised iron, earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board/panel board , all as specified and shown in MES schedule Electrical Plate No-5 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, RCC 1:2:4 type B1, 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoaldust, salt, funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed. Note : Value of earth resistance shall not be more than 2 Ohm. 109 M&L in repairs galvanised iron strip 32x6mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof ofhigh rise bldg and as required by saddles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop all as specified and directed by the Engineer-in-Charge. 110 Supply and fixing substation insulation rubber floor mats not less than 2.5 mm thickness suitable for operation on 11 KV panels confirming to IS 15652 : 2006 all as specified and directed by Engineer-Incharge.
Contract Date: Apr 27, 2026 Contract Value : 32.04 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
48.
Public Administrative Department #10852137 Technical Bid
Tender For Supply, Installation And Commissioning Of Machinery For Shree Saibaba I.T.I, Shirdi. Tools, Equipment, Instrument List (As Per New Syllabus -All Trade) 1) Trade- Fitter , Pipe Cutter 6 To 25Mm Wheel Type Make - Stanley/ Ingco/Taparia / Bharat /Jk , Pipe Bender Spool Type Up To 25.Mm With Stand Manually Operated Make - Beekay / Breeze /Indar/ Voltz /Stanley , Ss And Sc Centre Lathe (All Geared) With Minimum Centre Height 6/150 Mm & Center Distance 1000 Mm Along With 3, 4 Jaw Chuck, Auto Feed System, Coolant Arrangement, Lightening Lamp, Taper Turning Attachment, Safety Guard & Standard Accessories. Make - Kirloskar / Hmt / S Micrometric , Drilling Machine Pillar Sensitive 0-20 Mm Capacity With Swivel Table Motorize With Chuck & Key Make - Panchal / Skp / Eifco /Makita , Drilling Machine Bench Sensitive 0-12 Mm Capacity With Motorize With Chuck & Key Make -Panchal /Skp / Eifco / Makita , Compressor Unit:- Suitable For Pressure - 8 Bar, Delivery-50Lpm Or More, Receiver Capacity-24 Liters Or More, 250V,50 Hz, With Pressure Regulator And Water Separator Make - Fuji / Air Master/ Elgi/Ingersol Rand , Pneumatic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories. Single Acting Cylinder- Max. Stroke Length 50Mm, Bore Dia 20Mm - 1 No. Make - Extreme / Genitic / Parker / Koganei , (Ii) Double Acting Cylinder - Max.Stroke Length 100Mm, Bore 20Mm, Magnetic Type - 1 No. , (Iii) 3/2 Way Valve Manually-Actuated, Normally Closed. - 2 Nos. , (Iv) 3/2- Way Valve Pneumatically-Actuated Spring Return 1 No. , (V) One Way Flow Control Valve - 02 Nos. , (Vi) 5/2-Way Valve With Manually-Operated Switch-1No. , (Vii) 5/2 Way Valve-Pneumatically Actuated Spring Returns. , Viii) 5/2 Way Pneumatic Actuated Valve Double Point-1 , (Ix) 3/2 Way Roller Lever Valve Direct Actuation Normally Closed. - 02 Nos. , (X) Shuttle Vale - 01 No. , (Xi) Two Pressure Valve (And) - 01 No. , (Xii) Pressure Gauge 0-16 Bar - 01 No. , (Xiii) Manifold With Self-Closing Nrv-6 Way - 01 No. , (Xiv) Push Button Station For Electrical Single Point With 3 Illuminated Momentary-Contact Switch (1No + 1 Nc) And 1 Illuminated Contact Switch (1No+1Nc), Contact Load 2 A.- 01 No. , (Xv) Relay Station- With 3 Relay Each With 4 Contact Set (3No + 1Nc) Or Change Over Type, 5 A. - 01 No. , (Xvi) 3/2 Way Single Solenoid Valve With Led - 01 No., , (Xvii) 5/2 Way Single Solenoid Valve With Manual Override And Led - 01 No. , (Xviii) 5/2 Way Double Solenoid Valve With Manual Override And Led - 01 No. , (Xix) Power Supply Unit - Input Voltage 85-265V Ac, Output Voltage; 24V Dc, Out Put Current-Max.4.5A., Short Circuit Proof. - 01No. , (Xx) Profile Plate, Anodized Aluminum. 1100X700Mm. With Carriers, Maintenance Of Punting Frames And Mounting Accessories (Tube Fitted On To The Pneumatic Workstation. - 01 Set , Pneu, Matic Workstation With 40 Square Mm Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handle And Individual Locks, On Metallic Full, Panel Drawer Slide , (1) Work Table Size 1200Mm (L) X900Mm (W) X900Mm. (H), With Four Custard Wheel Including Two Lockable Wheel At The Front Side. , Drawer Size - L 460 Mm X W 495Mm. X H 158Mm. Each And Overall Size Of Drawer Unit (Apex) L 470Mm X W 495Mm X H 825Mm , (3) Drawer Slide Height (Apex) 85Mm. , Carrier For Mounting Components, Such As Pb & Relay Boxes. Cut Section Model For Pneumatic Components. , Hydraulic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories Make - Hitachi / /Tecno / Power Tech / Cad Mech Engineering / Equator Hydraulic , 1) Hydraulic Power Pack: - With (1) External Gear Pump Having A Delivery Rate Of 2.5 Improvement (Apex) (A) 1400 Rpm Operating Pressure 60 Bar, Coupled To A Single-Phase Ac Motor (230V Ac) Having Starter Capacitor And On/Off Switch And Overload Protection, , 2) Pressure Relief Valve Adjustable From 0-60 Bar , 3) Oil Reservoir, 5 Liters Capacity Having Sight Glass, Drain Screw, Air Filter And P And T Ports. - 01 No. , Ii) Pressure Relief Valve Pilot Operated - 01 No. , Iii) Drip Tray, Steel 1160Mmx760Mm. - 01 No. , Iv) Pressure Gauge Glycerin- Damped, Indication Range Of 0-100 Bar. - 01 No. , (V) Four-Way Distributor With Five Ports, Equipped With A Pressure Gauge. - 01 No. , (Vi) Double Acting Hydraulic Cylinder With A Control Cam, Piston Diameter 16Mm.,Piston Rod Diameter 10Mm,Stroke Length 200Mm. - 01 No. , (Vii) Suitable Weight For Vertical Loading Of Hydraulic Cylinder - 01 No. , (Viii) Mounting Kit For Weight For Realizing Pulling And Bushing Lead. - 01 No. , (Ix) 3/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (X) 4/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (Xi) 4/3 Way Directional Control Valve. Closed-Center Position, With Hand Lever Actuation - 01 No. , (Xii) Non Return Valve - 01 No. , (Xiii) Pilot Operated Check Valve Pilot To Open -01 No , (Xiv) One Way Flow Control Valve With Integrated Check Valve. - 01 No. , (Xv) T-Connector With Self-Sealing Coupling Nipples (2 Nos.) And Quick Coupling Socket (1 No.) - 02 Nos. , (Xvi) Profile Plate: - Anodized Aluminum, 100X700Mm With Carriers, Mounting Frames And Mounting Accessories (To Be Fitted Onto The Hydraulic Work Station. - 01 Set , Hydraulic Work Station With 40 Square Mm. Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handles And Individual Locks, On Metallic Full Panel Drawer Slide. , (1) Work Table Size (Apex) L1200Mm. X W900Mm. Xh900Mm. With Four Castor Wheel Including Two Locale Wheel At The Front Side. , Drawer Size (Apex) L460 Mm X W495Mm. X H158Mm Each, And Overall Size Of Drawer Unit (Apex). L470Mm X W495Mm. X H825Mm. , (3) Drawer Slide Height (Apex) 85Mm. Cut Section Models For Hydraulic Components. , D.C. Shunt Generator With Control Panel,2.5 Kw, 220V & 3 Phase Squirrel Cage Induction Motor, 5 Hp,440V With Control Panel & Star Delta Starter 1) Dc Generator Make - Crompton / Bharat Ele. Motor/ Kirloskar / Electronech / Power Way Systems 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor-Generator (Ac To Dc) Consisting Of : Squirrel Cage Induction Motor With Star Delta Starter And Directly Coupled To Dc Shunt Generator And Switch Board Mounted With Regulator, Air Breaker, Ammeter, Voltmeter, Knife Blade Switches And Fuses, Set Complete With Case Iron And Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Induction Motor Rating ;- 7.5 Hp, 415V, 50 Cycles, 3Phase Dc Shunt Generator Rating ;- 5Kw,440V (Output Voltage Varies 110-440V) 1) Dc Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Series Motor Coupled With Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Shunt Motor Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Compound Motor With Control Panel Including Spring Balance Load, Starter And Switch- 2.5 Kw, 220Volts 1) Dc Compound Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor Generator(Dc To Ac) Set Consisting Of - Shunt Motor With Starting Compensator And Switch Directly Coupled To Ac Generator With Exciter And Switch Board Mounted With Regulator, Breaker, Ammeter, Voltmeter Frequency Meter, Knife Blade Switch And Fuses Etc. Set Complete With Cast Iron Bed Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Shunt Motor Rating: - 5Hp, 440V, A.C., Generator Rating: - 3-Phase, 4-Wire, 3 Kva, 400/230 Volts, 0.8Pf, 50Cycles. 1) Dc Shunt Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) A. C. Generator Make - 1. Kirloskar 2. Crompton, 3. Siemens / Abb 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Squirrel Cage Motor With Star Delta Starter And Triple Pole Iron Clad Switch Fuse With Mechanical Loa,5 Hp,3-Phase ,415 Volts, 50 Hz 1) Ac Squirrel Cage Motor Make - 1. Crompton, 2. Siemens, 3. Hindustan Elec. Motor /Abb / Siemens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Phase-Wound Slip Ring Motor With Control Panel ,Starter And Switch 5 Hp, 440 V, 3-Phase, 50 Hz 1) Ac Phase-Wound Slip Ring Motor Make - 1. Crompton, 2. Siemens, 3. Havells Motor /Abb / Simens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard , Universal Motor With Control Panel, Starter/Switch 240 Volt, 50 Hz, 1 Hp 1) Universal Motor Make - 1. Crompton Greaves, 2. Hindustan Motor /Agni Motors / Integrated Elect Construction Of 3. Siemens / Bosch Power Tool 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Synchronous Motor With Control Panel Accessories. Like Starter, Excitation Arrangements,-3 Phase, 3 Hp, 440V, 50Hz, 4 Pole, 1) Synchronous Motor Make - 1. Kirloskar, 2. Crompton, 3. Siemens / Abb 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor /Igbt Controlled D.C. Motor Drive With Tacho-Generator Feedback Arrangement 1 Hp (Complete Set) 1)Thyristor /Igbt Controlled D.C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb / Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor / Igbt Controlled A.C. Motor Drive With Vvvf Control 3 Phase, 2 Hp (Complete Set) 1) Thyristor /Igbt Controlled A .C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Transformer, Core Type, Air Cooled, 1 Kva , 240/415 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Technovision Energy /Servokon /Sahara , Three Phase Transformer, Shell Type, Oil Cooled With Delta / Star 3 Kva , 415/240 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Servocon / Kay Pee , Electrical Machine Trainer - Suitable For Demonstrating The Construction And Functioning Of Different Types Of Dc Machines And Ac Machines (Single Phase And Three Phase). Should Be Fitted With Friction Brake Arrangement, Dynamo Meter, Instrument Panel And Power Supply Unit. 1) Dc Machines And Ac Machines Make - 1. Crompton 2. Kirloskar, 3. Siemens / Kitek Technology /Anshuman Tech 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Diesel Generator Set With Change Over Switch, Over Current Breaker And Water/ Air-Cooled With Armature, Star-Delta Connections Ac 3 Phase, 7.5 Kva, 415 Volt Or Higher Rating Make - 1. Kirloskar 2. Cummins 3. Mahindra Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Pillar Electric Drill Machine Motorized 12-20Mm. Capacity, 1 Hp,440V,3 Phase, Induction Motor With Dol Starter, Bench Type 1) Electric Motor -1. Crompton 2. Kirloskar 3. Siemens 2) Drill Machine Piller - 1. Prakash Engitech Pvt. Ltd. 2. Sri Vigneshwara Machine Tools. 3. Yogi Machine Tools / Itco Engg/ Liberty Metal /Jeet Machine , A.C. Series Type Motor With Control Panel 1 Hp, 240 V, 50 Hz 1) A.C. Series Type Motor Make - 1. Crompton 2. Kirloskar,3. Siemens /Abb / 2) Control Panel- Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Capacitor Motor With Control Panel , Starter Switch 1 Hp 240 Volt 50 Hz 1) Single Phase Capacitor Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Kirloskar 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Manual Motor Coil Winding Machine - With Step Arbour Make - 1. Chawla And Chudhari Trading Co. Pvt 2. Bgi Tools And Machine 3. Shree Esha Winding Technology / Sigva / Signatt / Heaven , Ceiling Fan Coil Winding Machine - 250V,50Hz, 1- Phase With Speed Control Make - 1. Bharat Machine Tools Ind. 2. Nishan Electric 3. Jangir Engineering Work / Kisan Engg / Nilkanth Electric , Primary Current Injection Set 220V,50Hz, 1-Phase,Output Current-200A(Min) With Timer Make - 1. Sb Electro Tech. 2. Pragati Process Controls, 3. Scope T&M Pvt / Udeytaj Electric / Motwane /Kpm Engg , Stepper Motor With Digital Controller Make - 1. Ajanta Export Industries. 2. Anubhuti Power System 3. Bombay Electronics 4. Siemens 5. Schneider Elect 6. Abb , Shaded Pole Motor Fractional Hp, With Control Panel 240V 50Hz 1) Shaded Pole Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Rexnord 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , D.C. Compound Generator With Control Panel Including Fitted Rheostat, Voltmeter, Ammeter & Breaker, 2.5 Kw, 220 V & 3 Phase Squirrel Cage Induction Motor 5 Hp, 440 V With Control Panel & Star Delta Starter. Make - Dc Compound Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar / Powerol 3- Phase 1) Induction Motor Make - 1. Crompton 2. Umiya Trading Company 3. Envirotech Engineers 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Used D.C. Generator Series, Shunt & Compound Type For Overhauling Practice. Make - 1. Crompton, 2. Bharat Ele. Motor 3. Kirloskar , Smart Meter 1- Phase - Smart Energy Meter 3 - Phase - Smart Energy Meter Make - 1.Genus Power Infrastructures Ltd 2.Hpl Electric & Power 3.Elmax India / L&T Electric , Ev Charger 3 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronic / Servotech Power System , Ev Charger (Home) 1 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronics , Work Shop Main Control Panel With Voltmeter Indicator Ammeter Indicator 1. Maintenance 125 A 440V 2. Output Main Switch - 16A - 08 , 32A - 08 63A - 02 Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , D C Control Panel Income - 440V Ac Output -12V ,24,110V, 240V, 440V, Dc With Indicator Voltammeter Ampire Meter Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , Welding Transformer With All Accessories ( 400A, Ocv 60-100 V, 60% Duty Cycle) Make - Miller / Ador / Esab / I Bell , Welding Transformer (Or) Inverter Based Welding Machine With All Accessories (300A , Ocv 60 - 100 V, 60% Duty Cycle) Miller / Ador / Esab / I Bell , D.C Annual Rate Contract Welding Rectifiers Set With All Accessories (400 A. Ocv 60 - 100 V, 60% Duty Cycle ) Make - Miller / Ador / Esab / Vigor , Gmaw Welding Machine 400A Capacity With Air Cooled Torch, Regulator, Gas Preheater, Gas Hose And Standard Accessories Miller / Ador /Esab / Kemppi , Ac/Dc Gtaw Welding Machine With Water Cooled Torch 300 A, Argon Regulator, Gas Hose, Water Circulating System And Standard Accessories. Miller /Ador / Esab / I Bell / Lincoln , Air Plasma Cutting Equipment With All Accessories, Capacity To Cut 12 Mm Clear Cut Make -Miller / Esab / Hypertherm / Rali Wolf / Technocard Plasma , Air Compressor Suitable For Above Air Plasma Cutting 15 Kw System Two Stage Compressor. 225 Ltr. Auto Cut Tank Cap. 80 -100 Psi Make -Elgi /Allas Capco / Ingersoll Rand / Premier , Auto Darkening Welding Helmet Make -L&T / Bell / Esab / Miller , Spot Welding Machine To 15 Kva With All Accessories Make - Ador / Esab/Artech / Micro Weld , Portable Gas Cutting Machine Capable Of Cutting Straight & Circular With All Accessories Make - Esab/ Pug Nm / Koike India /Ador / Pentagon , Pedestal Grinder Fitted With Coarse & Medium Grain Size Grinding & Wheel Dia-300Mm. Make -Elmaco / Bosch / Vijay Foundry Equipment , Bench Grinder Fitted With Grain Size Silicon Carbide Green Grinding Wheel Dia 150Mm Make - Elmaco / Bosch / Dewalt / Stanley Corded , Power Saw Machine 18 Hp-300 Blade Size - 450 Mm Make -Bosch / Dewalt / Hitachi / Kmi / Atlas Mochal , Portable Drilling Machine Capacity 6Mm. Make - Bosch / Dewal/ Hitachi , Oven Electrode Drying 0To 350C 10Kg Capacity Make - Ador /Arcon /Senso Heat , Die Penetrating Testing Kit. (Machine) Make - Esab / Dubi-Chek / Aerol / Magnaflux , Magnetic Particle Testing Kit. Make -Esab / Canmay /Mag Flux / Magnaflux / Magkraft , Wedding Simulators For Smaw,Gtaw,Gman (Optional) Make - Krb Electronic Soln Rewabsi / Simbott , Water Cooled Induction Welding/ Brazing Machine 200-250 Amp., Induction Coil Length 3 Inch And 2.5 Inch Make - Esab /Micro Tech Induction /Foster Induction /Vel I Braze Snapet / Welding World , Plastic Welding Machine With Hot Air Gun Temp. Display, Variable Temp., Pe, Pp& Pvc Sheet Or Pipe Welding Control With Stand. Accessories. Make - Esab / Leister / New Vimco Ltd /Ajanta Ultra Plast / I Bell / Vormik Vr/Branson Ultrascnies , Ag4 Grinder 100 Mm Dia Make - Dewalt / Bosch /Jk Supper / Metabo , Portable Abrasive Cut Off Machine 107 Mm Dia Make - Dewalt / Bosch / Ingco Hikoki /Mangalam / Century / Emboro , Hand Shearing Machine Cp Cut 6 Mm Sheet & Flat Make - Shakti / Vmt/ M.S. Machine Tools/Tl Pathak Group , Laser Cutting Machine Portable 50 Mm Laser Make - Esab / Toumf / Amada / Parag Weld Algo Laser/ Auto Mstack/Crealrty , Lathe S.S. & S.C. (All Geared Head Stock) With Minimum Specification As: 150Mm Centre Height To Admit 750Mm Between Centres, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 150Mm., 3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Travelling Study, Face Plate, Driving Plate, 4 Way Tool Post, Quick Change Gear Box For Metric Or British Threads, Live And Dead Centre With Taper Turning Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar /Hmt/ S Micrometric , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Between Centers, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 250Mm.,3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Traveling Steady, Face Plate, Driving Plate 1-Way Tool Post, Draw In Type Collets Set Up To 25 Mm, 0.5 Mm Relieving Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar / Hmt / S Micrometric , Grinding Machine Pedestal Type D.E.200Mm. Dia. Wheel With Wheel Guard And Vision, Motor Capacity - 0.75 Kw. Make - Elmaco / Bosch / Ingco , Cnc Lathe/Cnc Turn Centre Make - Bfw / Moriseiki / Makino , 1) Machine Capacity A. Swing Over Bed - 350 Mm Or Higher B. Turning Diameter - 135 Mm Or Higher C. Distance Between Centers - 250 Mm Or Higher D. Maximum Turning Length - 200 Mm Or Higher E. Slant Angle (Bed Or Saddle) -30 Degrees To Horizontal Or Higher F. Cast Iron Grade For Bed And Saddle - Grade 25 Or Equivalent G. Machine Weight Net - 1500 Kg Or Higher , 2) Spindle A. Spindle Nose -A2-4 / A2-5 B. Bore Through Spindle - 35Mm Or Higher C. Maximum Spindle Speed - 4000 Rpm Or Higher D. Spindle Power, Continuous - 3.7 Kw Or Higher E. Minimum Spindle Speed @ Full Power - 1200 Rpm, Or Lower F. Type Of Drive - Ac Servo Spindle Motor (Digital) G. Chuck Size -135 Mm Or Higher. Chuck Type H.3-Jaw Hydraulic, Hydraulic Power Operated I. Spindle Bearing Class - P4 Class J. Front Bearing Dia. (Id) - 60 Mm Or Higher , 3) Axes A. X - Axis Travel - 100 Mm Or Higher B. Z - Axis Travel -200 Mm Or Higher C. Programmable Feed Rate- X & Z -10 - 10000 Mm/Min D. Minimum Programmable Command -X & Z - 0.001 Mm E. Rapid Traverse - X & Z - 20 M/Min Or Higher F. Type Of Drive - X & Z - Ac Servo Motor G. Motor Torque - Z Axis - 3Nm Or Higher H. Motor Torque - X Axis - 3Nm Or Higher With Brake I. Ball Screw - Z & X Axes (Diameter X Pitch) - 25 X 10 Mm Or Higher J. Ball Screw Finish - Z & X Axes - Hardened And Ground K. Ball Screw Class- Z & X Axes - Pre-Loaded With C3 Or Better L. Guide Way Type - Z & X Axes - Antifriction Linear Motion Guide Way M. Guide Way Size - Z & X Axes - 25Mm Or Higher N. Guide Way Precision - Z & X Axes - P Class , 4) Turret A. Bi-Directional Tool Turret - Electromechanical/Servo/Hydraulic B. No. Of Tools - 8 Nos. Or Higher C. Tool Shank Size - 20 X 20 Mm Or Higher D. Maximum Boring Bar Diameter - 25 Mm Or Higher , 5) Tail Stock A. Quill Diameter - 65 Mm Or Higher B. Quill Stroke - 70 Mm Or Higher C. Quill Taper- Mt-4 Or Higher D. Quill Actuation - Hydraulic E. Tail Stock Base Travel Manual - 150 Mm Or Higher F. Thrust (Adjustable) - 300 Kg For Higher , 6) Coolant/Lubrication/Hydraulic A. Coolant Tank Capacity - 100 Liters Or Higher B. Coolant Pump Motor - 0.37 Kw C. Coolant Pump Out Put - 20 Lpm Or Higher D. Lubrication Type - Automatic Centralized Lubrication E. Lubrication Tank Capacity 3 Liter Or Higher F. Hydraulic Pump Discharge - 8 Lpm Or Higher G. Hydraulic Tank Capacity - 30 Liters Or Higher H. Hydraulic System Pressure Maximum -30 Bar Or Higher , 7) Accuracy As Per Iso 230-2 A. Positioning Accuracy X & Z Axes - 0.012Mm B. Repeatability X & Z Axes - ± 0.007Mm C. Geometrical Alignment - Iso 13041-Part 1 D. Accuracy Of Finish Test Piece - Iso 13041-Part 6 , 8) Cnc System A. Control System - Fanuc / Siemens B. System Resolution - 0.001 Mm C. Motors & Drives - Compatible With Cnc Controllers Mentioned Above D. Tool Number Display - On Machine Operator Panel E. Machine Control Panel - Feed Rate, Spindle Speed Override Knob F. Mpg (Manual Pulse Generator) - On Machine Operator Panel G. Cnc Features - Graphic Simulation, Programming Help, Tool Offsets, Mdi, Absolute/ Incremental Positioning, Pitch Error Compensation , 9) Power Source A. Mains Supply (± 10 %) - 415 V, 3 Ph., 50Hz B. Total Connected Load Requirement - Approx. 15 Kva , 10) Standard Equipment A. Voltage Stabilizer 15 Kva B. Air Conditioning Unit For Electrical Cabinet - 1 No. Backup Cd For Plc Ladder Logic - 1 No. D. Machine Lighting - 1 No. E. Levelling Pads And Jacking Screws - 4 No. F. Operation Manual - 1 No. G. Maintenance Manual - 1 No. H. Installation Kit - 1 No. I. Maintenance Tool Kit - 1 No. J. 6 Rack Trolley (Size 25X22X45) With Lock - 1 No. K. Machine Guarding With Safety Compliance - 1 No. , 11) Makes Of Critical Machine Tool Components A. Linear Motion Guide Ways - Hiwin/Thk/Pmi/Star B. Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C. Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D. Turret - Pragati/Baruffaldi/Sauter/Duplomatic E. Hydraulic Chuck & Cylinder - Gmt/ Kitagawa / Airtech /Pragati / Rohm F. Hydraulic Power Pack - Yuken/Fluid/Rexroth G. Panel Ac - Werner Finley/Rittal/Lextecnoid H. Stabilizer - Neel/Servomax /Consul/Farmax/Equivalent I. Lubrication- Cenlube/Dropco/Equivalent J. Coolant Pump - Rajamane/Grundfos K. Cutting Tools And Holders - Sandvik/Taegutec/ Kennametal /Seco/Iscar/Mitsub Ishi , 12) Cutting Tools & Tool Holders 1. External Turning Holder, Insert Type, Mwlnl - Holder 4Qty. (Insert Wnmg 40 Nos.) 2. External Turning Holder, Insert Type, Mvjnl - Holder 4Qty. (Insert Vnmg 20 Nos.) 3. External Turning Holder, Insert Type, Pdjnr - Holder 4Qty. (Insert Dnmg 20 Nos.) 4. Threading Holder - External, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 5. Threading Holder - Internal, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 6. Grooving Holder External, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 7. Grooving Holder Internal, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 8. Parting Off Holder For Insert Width 2 Mm, Lh - Holder 4Qty. (Insert 2Mm 30 Nos.) 9. Boring Holder Sclcl For Minimum Bore Dia. 12Mm - Holder 4Qty. (Insert Wcmt 60 Nos.) 10. Boring Holder Sclcl For Minimum Bore Dia. 16 Mm - Holder 4Qty. (Insert Ccmt 60 Nos.) 11. Internal Grooving Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert 2Mm 30 Nos.) 12. Internal Threading Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert W Mm 30 Nos.) 13. Insert Drill 12.7 Mm - Holder 4Qty. (Insert Suitable 30 Sets.) 14. Reducing Sleeves For Internal Holders - Dia 12 And 16 Mm - 2 Sets 15. Centre Drill Hss A 2.5 X 6.3 - 6 Qty. 16. Twist Drill Hss Straight Shank, Dia 6,8,10,12 Mm - 6 Sets 17. Collets Suitable For The Above Drills - 2 Sets 18. Collet Holder - 4 Nos. 19. Boring Bar Holder - 3 Nos C.N.C Lathe Machine With Accessories. 1. D- List Of Additional Machines, Tools And Equipment For Cnc Turn Center : D) Digimatic Electronic Vernier Caliper 200 Mm. - 2 Nos. E) Digimatic Electronic Outside Micro Meter (0 To 25 Mm & 25 To 50 Mm) Lc 0.001 Mm. - 1 Nos Each. , Desktop Computers Compatible To Run Simulation Software With Lan Facility. Dell / Lenovo / Hp Specification - Cpu - 64 Bit I7 Or Latest Processor Speed - 3Ghz Or Higher Ram 12 Gb Ddr - Iii Or Higher, Wi-Fi Enabled. Network Card - Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor (Min. 21 Inch.) Licensed Operating System And Antivirus Compatible With Trade Related Software. 01 Tb Hard Disk Nvidia Graphic Card , Ss And Sc Centre Lathe (All Geared) With Minimum Specification As: Centre Height 150 Mm And Centre Distance 750Mm Along With 4 Jaw Chuck, Self-Centering Chuck, Auto Feed System, Safety Guard, Motorized Coolant System And Lighting Arrangement, Set Of Lathe Tools, Lathe Carriers Make - Kirloskar /Hmt/ S Micrometric , Pillar Drill Machine (All Geared) 0-25Mm Drill Holding Capacity With Drill Chuck & Keys. Make - Ifco/ Skp / Energi , Cylindrical External Grinding Machine Fully Motorized With Dressing Arrangement And Supplied With Face Plates And Driving Dogs, 3 Jaw Self-Centering Chuck,4 Jaw Independent Chuck, Tail Stock Assorted Center Pump With Tank And Pipe Fittings Spanners And Grease Gun (Each Machine To Be Supplied With Assorted Grinding Machine For General Purpose Work With Internal Grinding Attachment) With Minimum Specification As: To Accommodate 750Mm Job With Center Height 150Mm. Wheel Diameter X Width=300X25Mm Make - Hmt-K 130 U / S-Micrometic / Hi Life , Radial Drilling Machine 32Mm Diameter With Std. Accessories. Drill Chuck & Plain Machine Vice 250 Mm Make - Hmt / Bfw / Batliboi , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Long With 3-Jaw, 4-Jaw Chuck Auto Feed System, Taper Turning Attachment, Coolant Pump, Safety Guard, And Machine Light Arrangement. Make - Kirloskar / Hmt / S Micrometric , Rockwell Hardness Testing Machine Digital Type With Standard Accessories / Digital Type Make - Mitutoyo/ Sagar/ Sinowon / Saroj / Sai Dro , Profile Projector (5 Micron) Re Solution 0.001Mm Projection Scream - Effective Diameter 300 Mm, Rotation Angle: +/- 360 Degree Angle Reading - 0.01 Degree Or 1 (Commutative) Projection Lens - 10 X Lens Group (Standard Arrangement) 20X50X100 X Is Set As On Option. Measuring Range - 200X200 Mm Quickly Move X, Y Axes, Power : 220 Vac Make - Mitutoyo / Nicon / Metzer , Co-Ordinate Measuring Machine (5 Micron) Measuring Range 500X700X500Mm Make - Nicon / Mitutoyo / Devine Technology , Fly Press (Any Model Minimum 12 Tons Capacity) Make - Taj Enterprises / Bharat Machinery And Spares / Orient Machine Tool , Power Press M/C (Hydraulic) Minimum 02 Tons Capacity Standard And Required Optional Accessories Make - Foreman / Amino / Omkar Enterprises , Auto Cad & Cam Latest Version - For Training Purpose Make - Autodesk , Solid Works / Any Latest - Latest Version - For Training Purpose Make - Dassasult System Solid Work Corporation , Smart Touch Screen Panel For Smart Class Room (65) Usb Connector, Led Interactive Pen, Mounting, Users Manual Electronics File Make - Samsung / Smart Guru / Vincon System , Multimedia Based Simulator For Cnc Technology & Interactive Cnc Part Programming Software For Turning & Milling With Virtual Machine. Operation & Simulation Using Popular Operation. Control System Such As Fanuc, Siemens, Etc. (Web-Based Or Licensed Based.) - For Training Purpose Make - Cad Mech / Indiasoft / Fanuc / Krb Electronic Solution , Cnc Vertical Machining Centre With Std. Accessories Make - Bfw / Moriseiki / Makino Specification , 1) Machine Capacity A)Table Size - 500X250 Or Higher Mm B) Max. Load On Table 150 Or Higher C)T Slot Dimension (N X W X P) Mm 3X14X100 Or Higher D)Table Height From Floor 800 ~ 900 Mm E) Cast Iron Grade For Bed And Saddle Grade 25 Or Equivalent F)Machine Net Weight 1500 Or Higher Kg , 2) Spindle A) Spindle Nose Bt30 B) Minimum Distance (Spindle Nose To Table)100 - 150 Mm D) Maximum Spindle Speed 6000 Or Higher Rpm E) Spindle Power, Continuous 3.7 Or Higher Kw F) Type Of Drive Ac Servo Spindle Motor (Digital) G) Spindle Bearing Class P4 H) Front Bearing Dia. (Id) 50 Or Higher Mm , 3) Axes A) X - Axis Travel 300 Or Higher Mm B) Y - Axis Travel 250 Or Higher Mm C) Z - Axis Travel 250 Or Higher Mm D) Rapid Traverse - X/Y/Z 20/20/20 Or Higher M/Min E) Minimum Programmable Command X/Y/ Z - 0.001 Mm F) Programmable Feed Range - X, Y & Z Axes 10 - 10000 Mm/Min G) Type Of Drive Ac Servo Motor H) Motor Torque - X & Y Axes 3 Or Higher Nm I) Motor Torque - Z Axis 6 Or Higher With Brake Nm J) Ball Screw - X,Y& Z Axes (Diameter X Pitch) 25 X 10 Or Higher Mm K) Ball Screw Finish - X, Y & Z Axes Ground And Hardened L) Ball Screw Class - X, Y & Z Axes Pre-Loaded With C3 Or Better M) Guide Ways - X, Y & Z Axes Antifriction Linear Motion Guide Way N) Guide Ways Size - X, Y & Z Axes 25 Or Higher Mm O) Guide Way Precision - X, Y, & Z Axes P Class , 4) Automatic Tool Changer A) Number Of Tool Pockets 8 Or Higher Nos B) Max Tool Diameter 80 Or Higher Mm C) Tool Selection Bi-Directional D) Tool Shank Type Bt30 E) Tool Weight Max 2.5 For Bt30 F) Tool Length Max 100 ~150 For Bt30 G) Tool Change Time (Chip To Chip) 5 Or Lower Sec H) Tool Clamp & Unclamp Disc Spring & Hydro-Pneumatic , 5) Accuracy As Per Iso 230-2 A) Positioning Accuracy For X,Y & Z Axes 0.012 Mm B) Repeatability For X,Y & Z Axes ±0.007 Mm C) Geometrical Alignment Iso 10791-Part 1 D) Accuracy Of Finish Test Piece Iso 10791-Part 7 , 6) Cnc System A) Control System - Fanuc B) Motors & Drives Compatible With Cnc Controllers As Mentioned Above C) System Resolution 0.001 Mm D) Tool Number Display On Machine Operator Panel E) Machine Control Panel Feed Rate, Spindle Speed Override Knob F) Mpg (Manual Pulse Generator) On Machine Operator Panel G) Cnc Features Graphic Simulation, Programming Help, Tool Offsets Mdi, Absolute/Incremental Positioning, Pitch Error Compensation , 7) Coolant/Lubrication A) Coolant Tank Capacity 100 Or Higher Litres B) Coolant Pump Motor 0.37 Kw C) Coolant Pump Output 20 Or Higher L Pm D) Lubrication Type Automatic Centralized Lubrication E) Lubrication Tank Capacity 3 Or Higher Liters , 8) Air Compressor For Tool Unclamp A) Compressor Type Screw Type With Dryer, Filter & Air Receiver B) Tank Capacity 200 Or Higher Liters C) Air Flow 10 Or Higher Cfm D) Pressure 7 Max. Bar , 9) Power Source A) Mains Supply (± 10 %) 415 V, 3 Ph., 50Hz B) Total Connected Load Requirement Approx. 15 Kva , 10) Standard Equipment A) Voltage Stabilizer 15 Kva B) Air Conditioning Unit For Electrical Cabinet As Required C) Backup Cd For Plc Ladder Logic 1 No. D) Machine Lightning 1 No. E) Levelling Pads And Jacking Screws 4 Nos. F) Operation Manual 1 No. G) Maintenance Manual 1 No. H) Installation Kit 1 No. I) Maintenance Tool Kit 1 No. J) 6 Rack Tool Trolley (Size 25X22X45) With Lock 1 No. H) Machine Guarding With Safety Compliance 1 No. , 11) Makes Of Critical Components A) Lm Guide Ways - Hiwin/Thk/Pmi/Star B) Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C) Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D) Atc - Pragati/Gifu E) Panel Ac - Werner Finley/Rittal/Lextecnoid F) Stabilizer - Neel/Se Rvomax/Consul/Farmax G) Lubrication - Cenlube/Dropco H) Coolant Pump - Rajamane/Gru Ndfos I) Cutting Tools And Holders - Sandvik/Taegutec/Ken Nametal/Seco/Mitsubishi J) Air Compressor (Capacity: 6 Kg/Cm2 - 300 Godrej/Elgi/Kaeser/Atlascopco L Pm Min.) , 12) Cutting Tools & Tool Holders (For Bt30 As Per Machine Supplied) A. Face Mill 45 Degree 63 Mm. Insert Type - 4 No. Suitable Inserts - 15 No. B. Face Mill Square Shoulder 50 Mm. Insert Type - 4No. Suitable Inserts - 15 No. C. Twist Drill Hss Straight Shank 6, 6.7, 8.5, 9.7 - 4 No. D. Spot Drill Carbide, Dia. 8 Mm X 90° - 4 No. Suitable Inserts - 60 No. E. Drill Insert Type - 16 Mm - 4 No. Suitable Inserts - 30 No. F. Solid Carbide Twist Drill Straight Shank - 8 Mm - 4 No. G. Solid Carbide End Mill Straight Shank - 10, 12 Mm Dia. - 4 No. H. End Mill Insert Type Straight Shank - 16 Mm Dia. - 4 No. Suitable Inserts - 30 No. I. Machine Taps Hss - M8, M10 - 4 No. J. Solid Carbide Reamer Straight Shank - 10 Mm - 4 No. K. Finish Boring Bar Dia. 20 To 25 Mm- 3 No. Suitable Inserts - 30 No L. Holder For Face Mills (Adapter) - 4 No. Suitable Incert - 60 Nos. M. Collets For Above Drills, Reamers, End Mills - 02 Sets N. Collet Holder Suitable For Collets - 4 No. O. Side Lock Holder For 16 Mm Insert Drill - 2 No. P. Machine Vice 0-150 Mm Range - Mechanical Type - 1 No. Q. C Spanner For Tightening Tools In Holder - 2 No. R. Magnetic Dial Stand - 2 No. S. Mallet - 02 No. T. Tap Wrench - 2 No. U. Hands Tools Set ( Spanners, Allen Keys, Etc.,) - 1 Box V. T Nuts, Strap Clamps, Clamping Nuts And Studs - 2 Set , Three / Four Door Refrigerator (Inverter Type) Specification - 300 Liter With Hc-600 A Gas. (1 Each) Make - Godrej / Whirlpool / Lg , Core Drill Machine Specification - Up To 2 To 2.5 Hammer Chiseling Bit 1500 Watt Make - Crompton / Power Hours / Bosch , Duct Able Split A/C Reciprocating Compressor Specification - Cap 1.5 Ton With R-22 Evapora(4 Copper) Make - Blue Star / Voltas / Daikin , Recovery Unit With Cylinders Specification - Cfc-Hfc,Hcfc, - 1 Each Cylinders Make - Trust Hal / Robin Air Rg-3 / Rishabh Enterprises , Decibel Meter 03 To 100 Db Make - Cadrim / Bosch / Generc , Descaling Pump Set With Stainless Steel Impeller And Accessories (1/2 Hp) Make - Bosch / Crompton / Robin Air , Fan Coil Unit With Water Valves Specification - 2 Way & 3 Way Valves (02 Ton) Make - Nutech Zeco / Blue Star / Voltas , Circulating Water Pump 0.5 Hp With Stainless Steel, Tank Capacity Inlet/Outlet Provision Make - Sharp / Lubi / Crompton , Water Cooler Storage Type Hfc-134A Specification - 200 Litter Reciprocating Compressor. Make - Blue Star /Voltas / Usha , Package A/C Air Cooled Type With Open Type Reciprocating Compressor Fins Type Condenser (05 Ton) Make - Blue Star / Voltas / Daikin , Bus A/C Tutorial Model Make - Estern Air / Tata Motors / Cool Ways. Ltd , Automatic Ice Coober Machine Specification - 5 Kg/Hr., Ice Cube - Material Stainless Steel Make - Godrej / Voltas / Blue Star , Walk In Cooler Puf Insulated Cold Room Specification - 01 Ton, 6X5X8 Foot, Cold Room Temp - 0 To 5° C Degree. Air Cooled Evaporator & Condenser Copper Tubing. Make - Unicool / Blue Star / Voltas , Shell Tube Type Dx Chiller Specification - 5 Ton Material - Copper Tubing Only Make - Voltas / Blue Star / Carrier
Contract Date: Ref. Documents Contract Value : Ref. Document
Trust & NGO No of Bidders 3
Maharashtra View Result →
49.
Defence #10832999 Price Bid
Tender For Additional / Alternator To Swimming Pool And Other Works Under Age B/R Iii At Chandimandir; 1 Dubbing out average 20mm thick on irregular faces of walls, exposed reinforced surfaces, in Cement and Sand mortar 1:4,including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified. 2 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 3 providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed 4 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 5 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base finished fair and rough without using extra cement, complete all as specified and directed. 6 Coloured non skid porcelain tiles exterior grade 300x300x 8-10mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed 7 Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. 8 Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, including 15mm thick in cement mortar 1:6, complete all as specified and directed 9 Coloured vitrified ceramic tiles, 10mm thick (square/rectangular ) , area of each tiles exc 0.18 Sqm but n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 10 20mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in, set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compelte all as specified and directed. 11 Kota Stone Slab flooring, 18-20mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. 12 Factory made machine pressed, pre polished, coloured chequered cement concrete tiles 250mm x 250mm x 20-22mm thick (with grey cement and no pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 13 Plain cement mortar 1:3:6 (type C-2 using 20mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,all as specified.Note: 10mm construction joint will be provided and panel should not be more than 3metre in length and joint filled with filler bitumen and sand in ratio (1:3) 14 Two coats of oil bound distemper on wall surfaces over a coat of primer including preparation of new plastered surfaces complete all as specified and directed 15 Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. 16 Applying Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paintof required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. 17 Prepartion of new surface and applying two coat of premium acrylic emulsion weather proof exterior paint over a coat of primer complete all as specified and directed. 18 Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, inclunding using water proofing compound complete all as specified.Note : WPC shall be measured and paid separately. 19 Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. 20 Rendering 15mm thickin Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. 21 PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement, complete all as specified and directed. 22 15mm thick (average thickness) rendering on roof surfaces inclduing flashings and junction of parapets etc finished even and fair in cement mortar 1:4 using water proofing compound as per manufacturers instruction after brushing cement slurry complete all as specified and directed 23 Supply only integral water proofing compound complete all as specified & directed. 24 3mm thick Atactic polypropylene polymer (APP) modified prefabricated water proofing membrane, based polymeric membrane minimum weighing 3kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished, complete all as specified & directed. 25 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete allas specified and directed. 26 Factory made steel window box type with side hung shutters including box type hinges and oneshop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete with glazing bars, dovetailed or welded fixed with and including MS flat of suitable size for fixing grills and guards bars etc , complete all as specified. 27 Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square, area not exc 0.5 sq. mtr in each pane,complete all as specified and directed. 28 Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,including filling of PCC 1:3:6 in hollow frame complete all as specified and directed. 29 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated, all as specified and directed. 30 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). 31 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge 32 Butt hinges 100mm size, of extruded aluminum alloy with galvanisedmild steel hinge pin, anodised, type C-21, complete all as specified and directed. 33 200 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 34 150 mm extruded aluminium handles cast typecomplete all as specified and directed. 35 Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. 36 Factorymade fixed type steel ventilator with glazing bar compelte all as specified and directed. 37 Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples, complete all as specified and directed. 38 preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 39 Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. 40 Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. 41 Two coats of synthetic enamel paint over priming coat onnew stone and concrete surfaces of any description not otherwise described over 10 cm width or girth including preparation of new surfaces complete all as specified 42 Hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and directed(Note : Colour/design and pattern shall be as decided by the GE) 43 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws, complete all as specified and directed 44 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws,fixed as in repair complete all as specified and directed 45 Rolled sections as in main and cross beams, hip and jack rafters,purlins where connectedto common rafters and running rails and guidesforsliding doors, fixedwithangle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed. 46 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O all as specified and directed. 47 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O including dismantling old iron all as specified and directed. 48 Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge 49 Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed. 50 TMT bars for reinforcement, 6 to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. 51 Pre-painted galvalume aluminium zinc (AZ-70) coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc , complete all as specified & directed by Engineer-in-charge. 52 Powder coated aluminium(minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, including making good dismantled portion with PCC (1:2:4) type B-1 in CM 1:3 complete all as specified and directed. 53 5.00mm thick ordinary quality tinted glass,fixed to aluminum frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. 54 Door closer hydraulically regulated aluminum (die cast) body, designation No 2, universal type, suitable for door shutters of 701mm to 850mmin width and of weight between 36 to 60 Kg,complete all as specified and directed. 55 Demolition of cement concrete (unreinforced) any description and in any position complete all as specified. 56 Demolition of stone slabs and tiles of any description or thicknessin floors laid, bedded and pointed in any mortar complete all as specified and directed. 57 Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed 58 Hard core ofbroken stone or boulders of gauge of guage n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 59 Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as speciied and directed. 60 Cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). 61 Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified. 62 Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. 63 Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. 64 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in beams, cantilevers , bressumers,lintels over 1.5m span, all as specified and directed . (reinforcement shall be measured and paid for separately). 65 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately). 66 Material and labour form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 67 Form work to chullah hoods, chajjas and similar items including edges / sides and soffits of lintelsetc rough finished surface of concrete flat complete all as specified and directed. 68 Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified. 69 Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed 70 Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed. 71 12mm thick toughned glassas in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holeswith necessary screws/ beading, rubber packing, L patch bottom and top, self closing patch etc,complete all as specified and directed.NOTE : Decoratiion/Design or unit name, emblem, crest over glass shutter will be approved by Engr-in-Charge before executionand the rates are inclusive of the same 72 Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. 73 300 mm long stainless steel handle, fancy type , fixed to toughened glass, complete all as specified and directed. 74 Stainless steel lock for 10-12mm thick glass door, having knob inside with three keys, satin finish, complete all as specified and directed. 75 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. 76 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. 77 All as per serial item 76 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed 78 All as per serial item 76 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 79 All as per serial item 76 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area) cable as earth continuity conductor 80 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 81 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 82 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 83 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 84 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 85 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 86 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 87 LED lamp9 watts, B-22 type complete all as specified . 88 Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCBs ,MCBs etcand removing from site, Complete all as specified and directed . 89 MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 90 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . 91 TPN distribution board double door flush mounting with provisions for MCB TPN 6 way, 415 volts having IP 43 protection Complete all as specified and directed . 92 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 93 MCB, DP, 240 volt,32Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 94 MCB, SP, 240 volt,40 to 63Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 95 MCB SP , 240 volt, 6Amps to 32Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 96 MCB , TPN/FP 40 to 100 Amp 415 volts, 16 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 97 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP 20 Amp MCB complete all as speicified and directed. 98 Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose tofan complete all as specified and directed. 99 LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed. 100 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completecomplete all as specified and directed. 101 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. 102 LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. 103 Exhaust fan energy efficient metallic blades heavy duty turbo force of size 300mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washerscomplete all as specified and directed. 104 Wall mounted fan PVC body, 400mm sweep, 230 volt , AC,quick start torque motor with copper winding complete all as specified and directed. 105 LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ncluding taking down any type ceiling fittingcomplee all as specified and directed. 106 LED flood light fitting 100 Watt 6500K outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrision resistantincluding thermal management in multiple optics complete with IP 65 protectioncomplete all as specified and directed. 107 Suface mounting back lit LED 1 x 4 tile in CRCA housing with full opel diffuser for soft & glare free distribution panel with surge protection complete including cutting hole of required size in POP/false ceiling making good disturbedincluding taking down any type ceiling fittingcomplee all as specified and directed. 108 Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 109 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE: (i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 110 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. 111 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), completeall as specified and directed. 112 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. 113 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection,complete all as specified and directed. 114 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 3.5core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 115 32mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
50.
Public Administrative Department #10809106 Price Bid
Tender For Electric Work In Municipal Area Sultanpur- 1 Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR Poles with Octagonal Cross Section 9 Mtr. 2 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Single arm overhang 3 Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 4 LED Street Light fixture with Minimum lumen output 3700 lm 5 LED Street Light fixture with Minimum lumen output 5600 lm 6 LED Street Light fixture with Minimum lumen output 8700 lm 7 LED Street Light fixture with Minimum lumen output 15000 lm 8 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . High Power LED Flood Light Minimum lumen output 25000 lm 9 Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discoms standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 75mm x 90mm 10 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 11 Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discoms specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR LT cross arm 600 mm long with clamp 12 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq.mm 13 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 14 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 A to 32 A rating 15 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 50/63 A rating 16 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 80 Amp 17 SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSRup to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 18 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approve One day & week reserve (digital type )d by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 19 Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 8.0 Mtr long PCC pole of 200 Kg Working Load 20 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discoms standard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 21 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3 X 25 sq. mm. + 1X25 sq. mm. (insulated) 22 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 2 core 23 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4 core 24 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 3.5core 25 P & F of IP 55 protected light controlled switch based oninfrared sensing and daylight with built in over loadprotection, timer to switch OFF at preselected time.Switch shall have 7 day power backup withouthampering of preset time and over ride facility formaintenance purpose Suitable for 15 kw load (three phase) includingcontactor, MCB, cable glands, terminal block andlocking arrangement 26 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 mm Dia. 27 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 28 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 SWG G.I. ( Hot Dipped ) Wire 29 Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 30 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. 31 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR B class 50mm dia 33 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer Cement Concrete Grade M-15 and above and PCC blocks 34 Providing & Fixing of ISO certified company made bolted type/ Din type HBC (High breaking capacity) fuse links of 80 KA breaking capacity,as per PWD specification for electrical Works conforming to IS:13703 in the existing fuse base, fuse switch unit etc. of the following type and rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 63 A to 160 A Size 00 35 Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 6.0 sq.mm 36 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or teeconnections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 37 LINE MAN/WIRE MAN Annual Rate Contract of regular opration and maintence and Changing faulty spare parts, sheets, Wire and Door Switch of all existing pannel complete for 12 month (30 PENNEL) 38 Annual Rate Contract of regular opration and maintence of all type LED street lights fixure with all wattage (20,40,70,130,200)/ HIGH MAST with Complate materials, Drivers, Glass, Chip, Wire, etc Complate Including Line Maintence For 12 Month Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
TenderDetail
Loading tenders