View Bid Results For Gis Substation Tenders

We found 1062 Bid Results related to gis substation tenders. You can find Contractor details who won gis substation tenders along with contract details in Bid awards announcements section.

Filters
Stage
580
280
202
Tender Publishing Platform
97
965
State / UT
30
362
128
107
64
46
44
41
41
33
31
20
19
17
16
12
12
12
12
9
7
6
5
4
3
3
2
2
2
1
1
Contract Value
497
186
246
133
Publish Date
6
0
0
0
0
Sector
22
805
73
26
26
25
24
16
11
11
9
7
6
5
4
4
2
2
2
1
1
1
1
Ownership
5
486
483
78
14
1
Within keyword
Active filters:
Showing 1–22 of 1062 tenders matching your filters
2.
Power #11466146 Price Bid
Tender For Repair Work Under O&M Head Of Damage Caused Due To Storm/Hurricane/Accident/Other Special Reasons Under 33 Kv Vertical, Bareilly. (Running Contract)=- 1 The Work Of Safe Carriage Of Following Materials From The Electricty Store Centre Cb Ganj, Bareilly To The Working Site Including Loading And Unloading At Both Ends. (Distance 0 To 50 Km) 2 Stp Pole 13 Mtr. Long 3 Stp Pole 11 Mtr. Long 4 Pcc Pole 11 Mtr. Long 5 Pcc Pole 9 Mtr. Long 6 Acsr Dog Conductor 7 Acsr Panther Conductor 8 33 Kv Cross Arm 9 33 Kv Pin Insulator With Pin 10 33 Kv Disc Insulator 11 33 Kv Disc Fitting 12 Stay Set Complete 13 Top Channel For 33 Kv 14 T-Off Channel For 33 Kv 15 33 Kv Xlpe Cable 3X300 Sqmm 16 11 Kv Xlpe Cable 3X185 Sqmm 17 11 Kv Xlpe Cable 3X120 Sqmm 18 Complete Work Of Installation/Replacement Of The Material Received From Electricty Store Centre Cb Ganj, Bareilly At The Working Sites As Per Respo Norms . 19 Work Of Installation/Replacement Of Single Stp Pole ( 13 Meter) With Proper Grouting Upto Depth Of One Sixth Of Length Of Pole And Mounting Of All Accessories Like Pin/Disc Insulator, Angle Channel, Cross Arm Etc.As Per Respo Standards And Decentralized Material Shall Be Provided By The Contractor/Firm. 20 Work Of Installation/Replacement Of Single Stp Pole ( 11 Meter) With Proper Grouting Upto Depth Of One Sixth Of Length Of Pole And Mounting Of All Accessories Like Pin/Disc Insulator, Angle Channel, Cross Arm Etc.As Per Respo Standards And Decentralized Material Shall Be Provided By The Contractor/Firm. 21 Work Of Installation/Replacement Of Single Pcc Pole ( 11 Meter) With Proper Grouting Upto Depth Of One Sixth Of Length Of Pole And Mounting Of All Accessories Like Pin/Disc Insulator, Angle Channel, Cross Arm Etc.As Per Respo Standards And Decentralized Material Shall Be Provided By The Contractor/Firm. 22 Work Of Installation/Replacement Of Single Pcc Pole (9 Meter) With Proper Grouting Upto Depth Of One Sixth Of Length Of Pole And Mounting Of All Accessories Like Pin/Disc Insulator, Angle Channel, Cross Arm Etc.As Per Respo Standards And Decentralized Material Shall Be Provided By The Contractor/Firm. 23 Complete Work Of Laying/Installing /Stringing Of Acsr Dog Conductor On The Installed Electric Poles As Per Respo Norms. 24 Complete Work Of Laying/Installing /Stringing Of Acsr Panthar Conductor On The Installed Electric Poles As Per Respo Norms. 25 Complete Work Of Laying/Installing /Stringing The 33 Kv Xlpe Cable (3X300 Sqmm) As Per Respo Norms. 26 Complete Work Of Laying/Installing /Stringing The 11 Kv Xlpe Cable(3X185 Sqmm) As Per Respo Norms. 27 Complete Work Of Laying/Installing /Stringing The 11 Kv Xlpe Cable(3X120 Sqmm) As Per Respo Norms. 28 Complete Work Of Re-Sagging / Tightening The Loose Line Of Dog Conductor Upto Proper Height On The Installed Electric Poles As Per Respo Norms. 29 Complete Work Of Re-Sagging / Tightening The Loose Line Of Panther Conductor Upto Proper Height On The Installed Electric Poles As Per Respo Norms. 30 Installation/Replacement Of 33 Kv Cross Arm As Per Respo Norms. 31 Installation/Replacement Of 33 Kv Pin Insulators With Pin As Per Respo Norms. 32 Installation/Replacement Of 33 Kv Disc Insulator As Per Respo Norms . 33 Installation/Replacement Of 33 Kv Disc Fitting As Per Respo Norms . 34 Installation/Replacement Of Top Channel For 33 Kv As Per Respo Norms . 35 Installation/Replacement Of T-Off Channel For 33 Kv As Per Respo Norms . 36 Complete Work Of Installation Of Stay Set Complete With Concreting On Installed Double / Single Pole Of Line As Per The Respo Standards. 37 Complete Work Of Cutting/ Pruning/ Trimming Of The Branches Of Trees For Making Proper Gap Between The 33 Kv Lines And Trees. 38 Work Of Straightening Of Tilted St Poles And Work Of Repairing Of Damaged St Pole (9/11/13 Meter ) At The Bottom By Providing Fixing 03 Nos. Angle Pieces Of Size 50X50X6 Mm Of 75 Cm Alongwith Grouting With Plinth Of St Poles With 1:4:8 Mixture In Size (450X450X1500Mm.) Including Cost Of Cement/Bb & Sand Required As Per Respo Norms. 39 Chemical Earthing Of T/F As Per Respo Norms.( All Material Shall Be Provided By The Contractor At His Own Cost) 40 Water Level Earthing Of T/F Body & Neutral With Gi Pipe Of 1.5\ Dia. Upto 60 Feet Depth Including G.I Strip Size 50X6 Mm. As Per Respo Norms. (Material Shall Be Provided By Contractor). 41 Supply & Fixing Of Following Materials. 42 Supply & Fixing Of Holding Clamps For All Sizes . 43 Supply & Fixing Of Copper Tinned Fuse Wire Of Size 12 Swg Appropriate Size 44 Supply & Fixing Of Copper Tinned Fuse Wire Of Size 16 Swg Appropriate Size 45 Supply & Fixing Of Nut & Bolt As Per Respo Standards 46 Supply & Fixing Of F-Clamp As Per Respo Standards 47 Supply & Fixing Of Pg Clamps Suitable For Dog Conductor 48 Supply & Fixing Of Pg Clamps Suitable For Panther Conductor 49 Safe Carriage Of Old & Used/ Damaged Material From Working Sites To Electricity Store Centre, Bareilly Including Loading And Unloading At Both Ends. 50 Line Material (Insulator, Disc, X-Arm, Angle, Channel Etc.) Old & Used/Damage 51 Stp Old & Used / Damage 52 Installation/ Replacement Of Defective 33 Kv Ct, 33 Kv Pt, 11 Kv Ct & 11 Kv Pt At 33/11 Kv Substations With Proper Wiring And Testing Including Safe Carriage Of New Ct, Pt From Electricity Store Centre Cb Ganj, Bareilly To 33/11 Kv Substations.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
5.
Power #11402509 Technical Bid
Work On The Strengthening Of 11 Kv Feeders Under The Duddhi Substation (Within Duddhi Tehsil), Undertaken As Part Of The Business Plan For The Year 2026-27 Under The Electricity Distribution Division, Pipri.= 1 Centralized Materials,Loading Unloading & Safe Cartage And Errection Of New Stp/Pcc Poles And Other Materials From Electricity Store Center, Robertsganj To The Work Place And Proper Stocking. (Distance Up To 80 Km.) 2 Pcc Pole 8.5 M Long 3 Stp 11M Long 4 Acsr Dog Conductor 5 11Kv 3X185 Xlpe 6 Acsr Weasel Conductor 7 De-Centralized Materials, Provided By Contractor 8 11 Kv Dropper Channel 9 Earthing Complete (Chemical Pipe ) 10 11Kv 3X185 Xlpe Joint Kit Out Door 11 Pg Clamp Weasel To Weasel 12 Pg Clamp Dog To Dog 13 11 Kv Fuse Set 14 11 Kv Composite Polymer Pin Insulator 15 11 Kv Composite Polymer Disc Insulator 16 11Kv Disc Fitting 45 Kn (T&C Type) 17 F-Bracket For Fitting Top Insulator With Nut Bolt 18 11Kv T-Off 19 11Kv Top Channel 20 11 Kv Steel Cross Arm 21 Top/Dropper Angle/Lt Pole Clamps 22 Cross Arm Holding Clamp 23 Gi Wire 6 Swg 24 Guarding Angle With Clamp 25 Stay Complete (Stay Rod 16X180Mm, Stay Wire 5Kg, Stay Clamp,Bolt & Nut With Grouting) 26 Nut&Bolt (Varoius Size) 27 Earthing Of Pole By Ms Earthing Rod Of 20X2500 Mm And 6 Swg Earthing Wireetc. 28 Alluminium Lugs 70Sqmm 29 Alluminium Lugs 120Sqmm 30 Alluminium Lugs 240Sqmm 31 Work Of Following Materials As Per Resspo/Puvvnl Norms At The Work Site. 32 Carriage Of St/Pcc Pole For Construction Of 11 Kv Line From Store To Site, Erection And Grouting Of Single And Double Pole With Cement, Sand & Brick Blast And Digging Method With All Accessories. Proper Grouting Of Poles. 33 Eraction And Grouting Of Stay With All Accessories.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 2.43 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 2.13 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.23 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.62 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.25 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.23 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.49 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.56 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 82.05 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 87.63 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 72.79 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 91.04 Lakh
Boards / Undertakings / PSU No of Bidders 1
19.
Power #11376672 Technical Bid
Construction Of 03 Nos. 33 Kv Basani, Sarsawa, Ganeshpur Bays At 220 Kv Sub Station Harahua.- 1 Carriage Of Sub Station Structure By Private Carrier From Efu Naini Prayagraj To 220Kv Sub Station Harahua . Job Includes Loading Of Material By Shifting Of These From Storage Place To Road Side, Safely Loading Of These On Vehicle, Transportation Of Materials From Efu Naini Prayagraj To 220Kv S/S Harhua By Private Vehicle Having One Side Distance Approx. 140Kms. Unloading Of Material From Vehicle Safely And Shifting These To Store And Proper Stacking. (Rate Includes All Labour, T&P Charges And All Associated Work To Perform The Job Satisfactorily) 2 Dismantling Of Pi And Its Structure Including With All Assosiate Work 3 Erection Of Structure Parts Of Main & Auxiliary Structure. The Job Consist To Shifting Of All Material, Structure Parts, Nut Bolts Washers Etc From Store To Work Site, Erection Of Structure As Per Relevant Drawing And Practices. 4 Erection Of Following Equipments As Per Instruction Manual Of Various Equipments Including Its Shifting From The Store To Site Including Other Associated Works To Complete The Job Satisfactory. 5 36 Kv Vcb 6 36 Kv Ct ( Metering ) 7 36 Kv Ct Junction Box (Metering) 8 36 Kv Ct(Protection) 9 36 Kv Ct Junction Box (Protection) 10 36 Kv Lsi 11 36 Kv Lsi Junction Box 12 36 Kv Bsi 13 36 Kv Bsi Junction Box 14 36 Kv Pi 15 33 Kv C&R Panel (Numerical Type) 16 Laying Of D/C 33 Kv Xlpe Power Cable Of Size 3Cx300 Sq.Mm Below 1000Mm From Ground Level Including Excavation Of Trench And Laying Of Cable And Putting Ist Class Bricks On Its 75Mm Edge Along With Cable On Both Side. Filling The Same With Ganga Sand And Then Putting Bricks On 380Mm/Patiya To Cover The Trench And Then Filling With Earth Including Cost Of Bricks Sand Miscellaneous And All Other Associated Work To Complete The Job Satisfactorily. 17 Hoisting Of 33 Kv 3Cx300 Sq.Mm Cable On Pole/Structure Through Gi Pipe Of Size 6\(150Mm) Dia 3 Mtr Long Including Its Jumpering With The Help Of Suitable Size Of Aluminium Lugs. 18 Termination Of Jointing Of Above Power Cable By 3Cx300 Sq.Mm Cable Jointing Kit O/D Type And All Other Associated Works To Complete The Work Satisfactorily As Per Technical Specification 19 Fabrication Fixing And Fitting Of Cable Structure In Shape Of H-Pole, 3 Mtr Long Including Its Grouting With Rcc Of Size 150X150X150Mm In Ratio 1:4:8 Including All Men Material Except Structure/Angle. 20 Jumpering Of Following Bay Equipments With The Help Of Acsr Panther Conductor Including Cutting Bending Clamping With All Other Associated Work From Main Bus To Outgoing Isolators For All Phases. 21 Laying Of Following Sizes Of Control Cable In The Cable Trenches From C&R Panel To Various Type Of Equipments, Junction Boxes In Switch Yard As Per Cable Schedule, Its Clamping/Binding At Every Two Meter Distance With Aluminium Sticks 25X1Mm Size Including Carriage Of Cable Drums From Store To Laying Site And Shifting Back To Store And All Other Associated Work To Complete The Job Satisfactorily As Per Tech. Specification: 22 2X2.5Mm²Control Cable 23 4X2.5Mm²Control Cable 24 6X2.5Mm²Control Cable 25 Termination Of Following Size Control Cable As Laid Above As Per Cable Schedule Including Making Necessary Holes In Glands Plate Of Junction Boxes , Supply And Fixing Of Cable Gland Ferrule Of Appropriate Size And Quantity Respectively For Each Core Of Cable And Its Termination With Crimping Type Lugs Including Lugs, Ferrules & Other Minor Accessories To Complete Job Satisfactory 26 2C X 2.5 Mm² 27 4C X 2.5 Mm² 28 6C X 2.5 Mm² 29 Fabrication Of Electrode By 40 Mm Dia Ms Rods In Length Of 3 Mtr By Making An Edge At One End For Ease In Piercing Below 1200Mm Into The Ground Using Wooden Hammer Completely At All The Junction Points Along With Welding & Painting At Outer Periphery Of Earth Mat As Per Relevant Is (M.S. Round Bar Shall Be Provided By Department). 30 Cutting Straitening Bending Laying Of 75X10 Mm Ms Flat For Earthing Of Main Structures Including Welding With Main Earth Mat Below 500-700 Mm Of Ground Level With Object To Earth Excavation Of Trenches Its Back Filling, Painting With One Coat Of Red Oxide Primer And Two Coats Of Synthetic Enameled Green Colour With All Cost Of Ms Flat, Paint, T&P Required For Completion Of Work. 31 Earthing Of Trench Along With 50X6Mm Ms Flat After Cutting And Welding With Cable Rack And Trench With All Cost Of Ms Flat, Including Painting With One Coat Of Red Oxide Primer And Two Coats Of Synthetic Enameled Paint. 32 Interconnection Of The Earth Mat Laid With The Existing Earth Mat Of The 220 Kv S/S Harahua At 10 Specified Point By Welding As That Complete Earth Mat Acts In Coherent Manner To Provide Proper Earthing Of The Substation. 33 Fabrication Of Display Board Made Of M.S. Angle Iron 50X50X6Mm, 3 Long Support And M.S. Board Of 2X1 M.S. Sheet 18 Gauge And M.S. Flat Iron 25X6Mm Size 2X1 Welded On M.S. Sheet After Then M.S. Pipe Of 1.5\ Dia. Fitted Around M.S. Flat On The Sheet Board And 0.5\ Dia M.S. Pipe 4\ Long Welded In M.S. Angle Iron From Two Places At One Side And Two At Other To Complete The Display Board. Digging Pit Size 2X2X3 And Grouting Above Board With 1:2:4 Cement, Ballast, Sand Ratio And Making Plinth Of Size 1X2. Board Shall Duly Painted By Yellow Color And Equipment Name Shall Be Written In Black. 34 Integration Of Newly Contructed 33Kv Bay With Iec 61850 Based Scada System. The Work Includes Sld Generation For Feeder Bay In Existing Hmi,Bay Ieds, Ics Files Configuraration Data Base Creation For Newly Bay ,Event Alarm Greeration ,Interlocks And Soft Logics Configuration And Testing If Any Gps Time Synchronisation Etc. 35 Supply 36 Pg Clamptarantull To Zebra Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 37 Pg Clamp Zebra To Zebra Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 38 Pg Clamp Panther To Panther Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 39 Pg Clamp Zebra To Panther Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 40 Supply Of Gi Nut Bolt Of Size 16X40Mm 41 Supply Of Gi Nut Bolt Of Size 16X45Mm 42 Supply Of Gi Nut Bolt Of Size 16X50Mm 43 Supply & Fixing Of 150W Outdoor Type Flood Light Complete Fitting With All Fixing Accessories Including Bracket And Clamps Of Philips/Crompton/Havells/Bajaj/Halonix Make. Original Warranty Card Should Also Be Submitted Along With Above Material. 44 Supply Of 75X10Mm Ms Flat 45 Supply Of 50X6Mm Ms Flat 46 Supply Of 25X6Mm Ms Flat
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 74.29 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 58.45 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 67.38 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 81.89 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 84.47 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 89.43 Lakh
Boards / Undertakings / PSU No of Bidders 1
27.
Heavy Industries and Public Enterprises #11319585 AOC
Tender For Electrical Works Required For Installation And Operation Of Radial Forging Plant Inside Msf, Ishapore.; 1 HV VCB PANEL - 1 (M & L): 5-Panel HT Switchboardto be connected with Cu busbars to the existing JYOTI make HT Panel at MRS-2 (3-nos.) & Pry-1 substation (2-nos.), Comprising of the followings: (Detailed specification is in ANNEXURE-1)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 1200 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: JYOTI, SIEMENS. 2 HV VCB PANEL - 2 (M & L): 2-Panel HT Switchboardto be connected with Cu busbars to the existing SIEMENS make HT Panel at MRS-1, Comprising of the followings: (Detailed specification is in ANNEXURE-2)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 1200 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: SIEMENS. 3 HV VCB PANEL - 3 (M & L): 6-Panel HT Switchboardto be connected with Cu busbars to the existing ALSTOM/SCHNEIDER make HT Panel at RF-1 substation, Comprising of the followings: (Detailed specification is in ANNEXURE-3)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 800 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: SCHNEIDER. 4 HT CABLE (M & L): Supply & laying of XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric power cable with aluminium conductor, 11000 volts grade, cross sectional area 300 sq.mm., 3 corefor (1) MRSto RF-1 S/S(two runs), (2) Tie link between MRS1 & MRS2, (3) Supply to T1 & T2, complete in all respect. Make: HAVELLS / GLOSTER / CRYSTAL / KEI. 5 HT CABLE TERMINATION (M & L): Supply & making of cable termination with termination-kit for 11 KV(E) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sq.mm. Make: RAYCHEM, DENSON, 3M. 6 HT CABLE ST. TH. JOINT (M & L): Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm. Make: RAYCHEM, DENSON, 3M. 7 TRANSFORMER 2500 KVA (M & L): Supply and installation of Transformer, step-down, 11-6.6/0.433 KV complete, outdoor type, copper wound, resin cast dry type of capacity 2500 KVA complete in all respect. (Detailed specification is in ANNEXURE-4. Drawing to be approved before manufacturing). Make: SCHNIEDER / VOLTAMP / RAYCHEM / ABB. 8 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). INCOMER & BUSLINK ACB 4000 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Incomer - 02 nos. & Buslink - 01 no. Make: SIEMENS / L&T / SCHNEIDER. 9 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING ACB 1600 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 10 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING ACB 1000 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 11 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING MCCB 400 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 400 Amp. Adjustable type (300 - 400Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 12 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING MCCB 250 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 400 Amp. Adjustable type (200 - 2500Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 13 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). INCOMING MCCB 800 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 800 Amp. Adjustable type (600 - 800Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 14 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). OUTGOING MCCB 250 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 250 Amp. Adjustable type (200 - 250Amps), Thermal Release with breaking capacity 36 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 15 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). OUTGOING MCCB 160 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 160 Amp. Adjustable type (100 - 160Amps), Thermal Release with breaking capacity 36 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 16 LT CABLE 300 SQ.MM.(M & L): Supply& laying of PVC/XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 300sq.mm., 3.5core, confirming to IS:7098, complete in all respect. Make: CRYSTAL, GLOSTER, FINOLEX, POLYCAB, UNIVERSAL, HAVELLS. 17 JOINTING / TERMINATION OF LT CABLE 240 TO 300 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 240 to 300 sq mm., complete in all respect. 18 LT CABLE 185 SQ.MM.(M & L): Supply& laying of PVC/XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 185sq.mm., 3.5core, confirming to IS:7098, complete in all respect. Make: CRYSTAL, GLOSTER, FINOLEX, POLYCAB, UNIVERSAL, HAVELLS. 19 JOINTING / TERMINATION OF LT CABLE 120 TO 185 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 120 to 185 sq mm., complete in all respect. 20 AIR CIRCUIT BREAKER 3200A (M & L): ACB 3200 Amps, 4 Pole, 415 V, Manual Drawout type to be Retrofitted in the existing LT Panel (HT shop) with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 21 AIR CIRCUIT BREAKER 1000A (M & L): ACB 1000 Amps, 4 Pole, 415 V, Manual Drawout type to be Retrofitted in the existing LT Panel (HT shop) with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 22 DISMANTLING & REFIXING OF LT AIR-BREAK (SWITCH) DB (L): Dismantling & refixing of LT AIR-BREAK (SWITCH) DB with accessories on MS angle with nuts, bolts etc. 23 EXCAVATION SOIL: Excavation of hard/dense soil over areas, n exc 1.5 m deep in cable trenches and getting out. 24 REFILLING OF SOIL: Returning, filling in, inc spreading, levelling, watering and well ramming of excavated soil for cable trenches. 25 SAND FILLING (M & L): Sand filling under cable trenches over laid cables. 26 GI CABLE TREY AND SUPPORTING COLUMN (M & L): Supply, fixing & febrication of rolled GI channel, angle, sheet, plates, rods and flats of different sizes for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. with Fe-410-W (Gde E-250) quality-B for fixing of prefebricated cable trays / supporting column of different sizes, supports etc., complete in all respect. The structure shall be hot dip galvanized with minimum thickness of coating not less than 80 microns. Galvanization shall conform to IS-2629, 4759 & 4736 as applicable. 27 REINFORCED CEMENT CONCRETE (M & L): Reinforced cement concrete (nominal mix)in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass cement concrete ofType B0 1:2:4 Type B1 1:2:4 (12.5mm graded (20 mm graded aggregate)concrete, complete in all respect. 28 FORMWORK TO CONCRETE (M & L): Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete in all respect. 29 TMT BAR STEEL REINFORCEMENT FOR CONCRETE (M & L): Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)6mm to 8mm dia or securing with clips, complete in all respect. 30 STEEL PIPE (M & L): Galvanised Steel Tubing (Piping), medium grade of bore size 100mm, including all fixing & fitting (MS clamps, flats) laid across drains, roads, fixing complete with all respect. Make: TATA, JINDAL. 31 DEMOLITION OF BRICKWORK & MASONRY (L): Demolition of Brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillers, etc. 32 CEMENT CONCRETING: Cement concrete in foundation, filling and mass concrete Type B2 1:2:4 (40mm graded aggregate), for repairing the demolished brick or masonery work on roads, hard standings & footpaths including tile-soaling, complete in all respect. 33 BRICK FOR CABLE SUPPORT (M&L): Supply & laying of Continuous brick edging; with width equal to the depth of the brick, laid dry, on edge With burnt clay bricks of sub class B, old size on two sides of laid cable. 34 BRICK WORK(M & L): Supply & making of Brick work with subclass B bricksbuilt in cement mortar 1:4 for making of walls & cable trench, complete in all respect. 35 CEMENT PLASTERING(M & L): Supply & making of Cement plastering 10mm thick on fair surfaces of brickwork or concrete surface, in cement mortar 1:4 (with net finish on floor), complete in all respect. 36 EARTH CONTINUITY CONDUCTOR (L): Supply & Fixinging of Earth ontinuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6mm galvanised iron strip. 37 EARTHING (M & L): Supply & making of Earthing for SS LT Switchgear, complete with galvanised steel earth plate electrode, 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge not less than 1.5 meter below ground level, connected with galvanised iron 32 x 6mm strip as earthing lead (upto 7.5m) by means of bolts, nuts, check nuts & washers of GI or GS all as shown in Plate No. 5 to the earthing test point all as specified and indicated including testing on completion. This includes making of pit, providing CI cover, funnel with watering pipe, wire mesh and GI earth lead protection pipe. 38 MS CHEQUERE PLATE: Supply & fixing of Rolled mild steel Plates (Chequered of 8 mm. thickness) [Fe 410-W (Gde-E- 250) quality-A] channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with 2-coat of red oxide primer for cable trench cover. 39 GI CHANNEL/ANGLE/FLAT (M&L): Supply, fixing & febrication of rolled GI channel, angle and flat, [Fe 410-W (Gde-E- 250) quality-A] fixed independently for fixing of LT PDB`s and making & fixing of cable trays / cable cover supports of different sizes, supports etc., complete in all respect. 40 UG CABLE 25 SQMM (M&L): XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm, 3½ core, complete in all respect. 41 JOINTING / TERMINATION OF LT CABLE 16 TO 35 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 16 to 35 sq mm., complete in all respect. 42 SUBMAIN WIRING (M&L): Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in existing surface/recessed as required of size 2x2.5 sq. mm + 1x1.5 sq. mm earth wire in steel conduit, junction box, complete in all respect. Make: MESCAB, HAVELLS, POLICAB, KEI, FINOLEX, ANCHOR. 43 160A MCCB WITH ENCLOSURE(M&L): Complete with the following in all respect. MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA to be fixed in the sheet GI steel enclosure. 44 160A MCCB WITH ENCLOSURE(M&L): Complete with the following in all respect. Sheet GI steel enclosure of size 2nos.x 0.5m x 0.5m x 0.3m, and spreader terminal, complete in all respect. Thickness of sheet in1.60 mm. 45 STEEL METAL ENCLOSURE FOR MCB DB (M&L): Supply, fixing & connection of Sheet metal enclosure for DB`s MCB to be used, Three pole and neutral, 4-way, 415 V, double door, complete in all respect. Make: SIEMENS / L&T / SCHNEIDER. 46 MINIATURE CIRCUIT BREAKER 5 TO 32A SP (M & L): Supply and fixing 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissionin, complete in all respect. Make: SIEMENS / L&T / SCHNEIDER. 47 POINT WIRING (M&L): Poing Wiring with copper conductor cables FRLS in stove enamelled Steel Conduit steel conduit for One light point or one fan point controlled by one switch with 2.5 sq. mm size PVC single core cables including earth wire, junction box, complete in all respect. Make: MESCAB, HAVELLS, POLICAB, KEI, FINOLEX, ANCHOR. 48 OH HIGH BAY LIGHT FITTING, 150W(M & L):Supply and fixing LED Overhead High Bay light fitting 1x150 Watt, IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED Overhead High Bay light fixtures driver, holders, connector etc. Complete with all accessories prewired and including fixing on overhead cross beam, connecting up with three core flexible copper conductor cable with suitable size, complete in all respect. MAKE: HAVELLS / PHILIPS / SURYA 49 SECURITY LIGHT FITTING, 90W(M & L):Supply and fixing LED Street light fitting 1x90 Watt, IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED Street light fixtures driver, holders, connector etc. Complete with all accessories prewired and including fixing on overhead column with GI bracket, connecting up with three core flexible copper conductor cable with suitable size, complete in all respect. MAKE: HAVELLS / PHILIPS / SURYA 50 AIR CIRCULATOR(M & L):Supply and fixing IndustrialHeavy Duty pedestal Air Circulator Fan, 30 (750 mm sweep, 415 VAC, 50 Hz, 1440 rpm, delivery-1700 CFM, 28900 m3/hr CI base, MS pipe, MS wire guard, Al. alloy casting, 4 wing blade motor with chord & MCB with enclosure, complete with paint.MAKE: POWER VENT/BAJAJ/CG/CALCUTTA FAN/ALMONARD 51 LOCK, 65MM (M & L):Brass 4 Lever Padlock of size 65mm for steel doors & rolling shutters. 52 SUBSTATION SCADA FOR HT & LT POWER DISTRIBUTION (M & L):Design, engineering, supply, installation and commissioningof MSF SCADA Systems for HT & LT power distribution as per enclosed ANNEXURE-7. complete in all respect.
Contract Date: Jun 26, 2026 Contract Value : 6.13 Crore
Government Departments No of Bidders 4
West Bengal View Result →
28.
Power #11319387 Price Bid
Tender For Under Business Plan 2026-27, Work Of Setting Up 100 Kva Additional Transformer In The Area Of ​​Substation Ghantaghar, Awas Vikas, Ambala Road, Jainbagh, Hussainbasti, Pulkhumran, Janaknagar, Kailashpur-2, Iti-2, Mankamou (Urban And Rural), Hakikatnagar In The Working Area Of ​​Electricity Urban Distribution Section-Technical, Saharanpur 1 Safe Carriage Of Other Line Material From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 2 Safe Carriage Of Pcc Pole 11 Mtr. Long From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 3 Errection Of 11 Mtr. Long Pcc Pole (Grouting Concreating Of Pole And Making Plinth) As Per Resspo Norms. 4 Safe Carriage Of Pcc Pole 9 Mtr. Long From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 5 Errection Of 9 Mtr. Long Pcc Pole (Grouting Concreating Of Pole And Making Plinth) As Per Resspo Norms. 6 Safe Carriage Of Pcc Pole 8.5 Mtr. Long From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 7 Errection Of 8.5Mtr. Long Pcc Pole (Grouting Concreating Of Pole And Making Plinth) As Per Resspo Norms. 8 Safe Carriage Of 100 Kva T/F From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 9 Safly Installation Of 100 Kva T/F On D/P 10 Safe Carriage Of Lt Abc 3X120+1X95+1X16 From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 11 Laying, Lifting & Stringing Lt Abc 3X120+1X95+1X16 As Per Site Requirments 12 Safe Carriage Of Lt Abc 3X95+1X70+1X16 From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 13 Laying, Lifting & Stringing Lt Abc 3X95+1X70+1X16 As Per Site Requirments 14 Safe Carriage Of Acsr Dog Conductor From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 15 Laying, Lifting & Stringing Acsr Dog Conductor As Per Resspo Norms 16 Safe Carriage Of Acsr Weasel Conductor From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 17 Laying, Lifting & Stringing Acsr Weasel Conductor As Per Resspo Norms 18 Providing & Fixing Of Ms Channel 100X50X6 Mm As Per Resspo Norms. 19 Providing & Fixing Of Ms Channel 125X65X6 Mm As Per Resspo Norms. 20 Providing & Fixing Of Ms Angle 65X65X6Mm As Per Resspo Norms. 21 Providing & Fixing Of Connecting Lead 1X16 Sqmm 22 Providing & Fixing Of Pg Clamp Dog To Dog 23 Providing & Fixing Of Pg Clamp 24 Fixing Of Stay Set 16X1800 As Per Resspo Norms. 25 Fixing Of Stay Wire 7/10 Swg As Per Resspo Norms. 26 Concreting Of Stay Set 27 Fixing Of Ms Earthing Rod (2540X20Mm) Complete As Per Resspo Norms, All Required Meterial Provided By Contractor . 28 Fixing Of Gi Wire 6 Swg As Per Resspo Norms. 29 Fixing Of Distribution Box 3-Phase 30 Carriage Of 3.5X400 Sqmm Lt Xlpe Cable From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 31 Laying, Lifting & Stringing Of 3.5X400 Sqmm Lt Xlpe Cable As Per Site Requirment 32 Carriage Of 3.5X150 Sqmm Lt Xlpe Cable From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 33 Laying, Lifting & Stringing Of 3.5X150 Sqmm Lt Xlpe Cable As Per Site Requirment 34 Carriage Of 3.5X70 Sqmm Lt Xlpe Cable From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 35 Carriage Of 1X240 Sqmm Lt Xlpe Cable From Pvvnl, Store To Site Including Loading & Unloading Both Ends. 36 Laying, Lifting & Stringing Of 1X240 Sqmm Lt Xlpe Cable As Per Site Requirment 37 Providing & Fixing Of Crimping Lug 400 Sqmm Lt Xlpe Cable 38 Providing & Fixing Of Crimping Lug For 1X240 Sqmm Lt Xlpe Cable 39 Providing & Fixing Of Lug As Per Required Sizes 40 Providing & Fixing Of Lt Piercing Connector 41 Providing & Fixing Ms Holding Clamp With Nut Bolts As Per Resspo Norms. 42 Providing & Fixing Ms Holding Clamp With J Hook As Per Resspo Norms. 43 Providing & Fixing Pg Clamp 44 Providing & Fixing Of 3-Phase Distribution Box Clamp 45 Providing & Fixing Lt Clamp With Nut Bolts As Per Resspo Norms. 46 Providing & Fixing Dead End Clamp With Nut Bolts As Per Resspo Norms. 47 Providing & Fixing Suspension Clamp 48 Providing & Fixing J Hook With Clamp 49 Providing & Fixing I Hook 50 Providing & Fixing Nut Bolts As Per Resspo Norms. 51 Providing & Fixing Stone Pad As Per Resspo Norms. 52 Providing & Fixing Danger Board As Per Resspo Norms. 53 Providing & Fixing Of Barbed Wire 54 Providing & Fixing Of Copper L-Piece 62X225X12 Mm 55 Providing & Fixing Danger Board Barbed Wire Including Jumper As Per Resspo Norms. 56 Providing & Fixing Of Number Plate 57 Fixing Of 11 Kv Tpmo As Per Respo Norms 58 Fixing Of 11 Kv Fuse Set As Per Respo Norms 59 Fixing Of 11 Kv X- Arm As Per Respo Norms 60 Providing & Fixing Of Lt Smc Fuse Set 61 Providing & Fixing Of Al. Leg Long Barrel Off Size (Ls) 62 Fixing Of 11Kv Polymeric Disc Insulator As Per Resspo Norms. 63 Fixing Of 11Kv Polymeric Pin Insulator As Per Resspo Norms. 64 Fixing Of 11Kv Polymeric Disc Fitting As Per Resspo Norms. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttar Pradesh View Result →
29.
Power #11316393 Technical Bid
Tender For Various Works Related To Installation Of New Distribution Transformers Of Various Capacities As Per E-Tender Specifications On Semi-Turn Basis Under Business Plan 2026-27- 1 Safe Carriage Of Following Materials From Store Centre Or From Any Other Place To The Respective Site Of Work Through The Kachha Pacca Road Including The Work Of Its Loading & Unloading At The Respective Ends, Also Including The Work Of Dragging Etc. And Also Including The Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work As Per Respo Norms. 2 Pcc Pole 8.5 Mtr. Long 3 St Pole 11 Mtr. Long 4 11 Kv Polymeric Disc Insulator 5 11 Kv Disc Fitting 6 11 Kv Polymeric Pin Insulator 7 V-Type Steel Cross Arm 8 Single Phase Transformer 16 Kva 9 11/0.4 Kv Tf 25 Kva 10 11/0.4 Kv Tf 63 Kva 11 11/0.4 Kv Tf 250 Kva 12 11 Kv Tpmo 13 Stay Set Complete 16X1800 14 Acsr Weasal Conductor 15 Acsr Rabbit Conductor 16 Cable Abc 3X50+1X35+1X16 Sq.Mm. 17 Cable Abc 3X95+1X70+1X16 Sq.Mm. 18 Cable Abc 3X120+1X95+1X16 Sq.Mm. 19 Three Phase Distribution Box 20 Supply & Erection Work Of Following Materials:- 21 Ms Channel (Dropper) 100X50X2028Mm (For Fuse Set) 22 Earthing Complete 23 11 Kv Fuse Set 24 Stone Pad 300X300X75Mm 25 Cross Arm Holding Clamp With N&B 26 Ms Channel 125X65X1300 Mm (T-Off) 27 Clamp For Lt T-Off With N&B 28 Holding Clamps For Top Channel Tpmo & Fuse Set With N&B 29 Ms Angle 75X75X6X2028Mm With Clamp N&B (T/F Base) 30 Ms Top Channel (125X65X2240Mm) 31 Lt Fuse Set Protection Unit For 63 Kva Dt With Smc Box 32 Lt Pvc Cable 3.5X70/35 Sq.Mm. 33 Danger Board With N&B 34 Barbed Wire Including Jumper 35 Three Phase Distribution Box 36 Three Phase Distribution Box Clamp 37 Suspension Clamp 38 Pg Clamp 39 Dead End Clamp 40 Eye Hook 41 Concreting Of Pole 42 Al Lug Long Barrel Off Size (Ls) 43 Henley Type Tailless Unit Protection Cubical Pannel 500A, 650V, 250 Kva Dt. 44 Copper L-Piece 50X225X10Mm (Ls) 45 Copper L-Piece 62X225X12Mm (Ls) 46 Lt Xlpe Cable Al 3.5X400 Sq.Mm. 47 Number Plate With N&B 48 Concreting Of Stay 49 F-Bracket For Fitting Top Insulator With N&B 50 Lt Clamp With N&B For Pcc Pole For Neutral 51 Lt Shackle Insulator 100X155Mm 52 Bolt & Nut For Shackle 53 Clamp With Nut Bolt 54 Body And Neutral Earthing Of 250 Kva Distribution Transformers Installed By Digging Of Pit Up To Water Level Depth (Approx. 100’) And Then Inserting 1-1/4\ Dia G.I. Pipe Of \B\ Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 50X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer Including The Cost Of Arrangement Of All Material, Labourer, T&P, Carrier Etc. Required For Proper Completion Of Work. 55 Construction Of 250 Kva Distribution Transformers Of Plinth Of Size 5’X5X4’ Above Ground Level And One Ft. Below The Ground Level Of 9”. After Excavation Of 4” Earth, Brick Ballast Shall Be Provided And Rammering Will Be Done Properly After That A Retaining Wall Of 9” Width By First Class Brick In Ratio 1:4 Of Cement And Sand Shall Be Made. The Earth Shall Be Filled Up To One Ft. Below The Top Of The Plinth. After This Brick Ballast Shall Be Provided Up To 6” From The Earth Level And Proper Rammering Shall Be Done. One No. Jall Of 12 Mm M.S. Tor Shall Be Fixed In The Hollow Of Plinth And One Ft. Thick Rcc In Ratio Of Cement, Sand And Stone Ballast Shall Be Laid On The Top Of The Plinth. The 12 Mm Thick Plastering Shall Be Done All Around The Plinth In 1:4 Ratio Of Cement And Sand. The Contractor Shall Be Responsible To Complete The Work As Per Direction Of Supervising Engineer. It Including The Cost Of All Material, Labour T&P, Carrier Etc. Required For Proper Completion Of Work. 56 Fabrication & Erection Of Fencing And Construction Of Retaining Wall Around Of 250 Kva Transformers.The Complete 11/0.4 Kv Substation Shall Be Provided With Two Meter Height Fencing And Retaining Wall Around The Substation. One No. Gate With Proper Locking Arrangement For Entry Of Personnel Shall Also Be Provided. The Fencing Shall Be Made Of 50X25 Mm X10 Swg Rectangular Welded Mesh Of Wire Mesh In Length. Wire Mesh Shall Be Fixed On Panels Made Of 50X50X6 Mm M.S. Angle. The Wire Mesh On Panels Will Be Supported By 25X3 Mm M.S. Flat On All The Bracings Diagonally And 50X6 M.S. Flat Horizontally At The Center Of The Panel. The Panel Will Be Joined By Bolts & Nuts Of Appropriate Size With Each Other And On The Main Support On Corners Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work. The Painting Of Complete Fencing Shall Also Be Done With One Coat Of Red Oxide Primer And Two Coat Of Synthetic Green Paint. For Construction Of Retaining Wall Around The Fencing, Excavation Of Earth Shall Be Done In Foundation In Ordinary Soil Including Disposal Of Surplus Earth At Some Suitable Distance. The Dimension Of Excavation Shall Be 1M Wide, 0.45 M Deep And Suitable Length As Per Wire Mesh. After Excavation Of Earth A Cement Concreted Pad Shall Be Laid In Foundation. Concreting Shall Be Done With Ist Class Brick Ballast, Coarse Sand And Cement In Proportion Of 8:4:1. First Class Brickwork Shall Also Be Done In Foundation And Super Structure In 1:6 Cement And Coarse Sand Including Necessary Cutting And Moulding Of Bricks In Foundation Depth Of Wall 0.30 M, Thickness Of Wall 0.35 M & Superstructure Brick Work Thickness Of Wall 0.23 M & Depths 0.30 M Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
30.
Power #11316387 Technical Bid
Tender For Various Works Related To Capacity Enhancement Of Distribution Transformers Of Different Capacities As Per E-Tender Specifications On Semi Turn Key Basis Under Business Plan 2026-27 Item.- 1 Safe Carriage Of Following Materials From Store Centre Or From Any Other Place To The Respective Site Of Work Through The Kachha Pacca Road Including The Work Of Its Loading & Unloading At The Respective Ends, Also Including The Work Of Dragging Etc. And Also Including The Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work As Per Respo Norms. 2 Pcc Poles 8.5 Mtr. Long 3 11 Kv Disc Insulator Polymeric T&C Type 4500 Kg. 4 11 Kv Disc Fitting 5 11 Kv Pin Insulator (Polymeric) 6 11/0.4 Kv T/F 25 Kva 7 11 Kv Tpmo 8 Stay Set Complete 16X1800 9 Cable Abc 3X50+1X35+1X16 Sq.Mm. 10 Three Phase Distribution Box 11 Acsr Weasel Conductor 12 11/0.4 Kv T/F 250 Kva 13 Lt Xlpe Cable Ai 3.5X400 Sq.Mm. 14 Cable Abc 3X95+1X70+1X16 Sq.Mm. 15 Supply & Erection Work Of Following Materials:- 16 Ms Channel (Dropper) 100X50X2028Mm (For Fuse Set) 17 Stone Pad 300X300X75Mm 18 Clamps For Lt T-Off With Bolts & Nuts 19 Holding Clamps For Top Channel Tpmo & Fuse Set. With B&N 20 Ms Angle 75X75X6X2028Mm With Clamp & B&N (T/F Base) 21 Ms Top Channel (125X65X2240Mm) 22 Ms Channel 125X65X1300Mm (T-Off) 23 L.T. Fuse Set Protection Unit For 25 Kva Dt With Smc Box 24 Danger Baord & Clamp With N & B 25 Barbed Wire Including Jumper 26 Earthing Complete 27 11 Kv Fuse Set 28 Concreting Of Poles 29 Dead End Clamp 30 Eye Hook 31 Suspention Clamp 32 Three Phase Distribution Box Clamp 33 Lt Pvc Armoud Cable 4X16 Sq Mm 34 Henley Type Tailless Unit Protection Cubical Pannal 500 Amp. 650 V For 250 Kva Dt 35 Copper L-Piece 50X225X10 Mm (Ls) 36 Copper L-Piece 62X225X12 Mm (Ls) 37 Al Leg Long Barrel Off Size (Ls) 38 Lt Pvc Cable Al 3.5X70/35 Sq.Mm 39 Lt Pvc Cable Al 3.5X150/70 Sq.Mm 40 Body And Neutral Earthing Of 250 Kva Distribution Transformers Installed By Digging Of Pit Up To Water Level Depth (Approx. 100’) And Then Inserting 1-1/4\ Dia G.I. Pipe Of \B\ Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 50X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer Including The Cost Of Arrangement Of All Material, Labourer, T&P, Carrier Etc. Required For Proper Completion Of Work. 41 Construction Of 250 Kva Distribution Transformers Of Plinth Of Size 5’X5X4’ Above Ground Level And One Ft. Below The Ground Level Of 9”. After Excavation Of 4” Earth, Brick Ballast Shall Be Provided And Rammering Will Be Done Properly After That A Retaining Wall Of 9” Width By First Class Brick In Ratio 1:4 Of Cement And Sand Shall Be Made. The Earth Shall Be Filled Up To One Ft. Below The Top Of The Plinth. After This Brick Ballast Shall Be Provided Up To 6” From The Earth Level And Proper Rammering Shall Be Done. One No. Jall Of 12 Mm M.S. Tor Shall Be Fixed In The Hollow Of Plinth And One Ft. Thick Rcc In Ratio Of Cement, Sand And Stone Ballast Shall Be Laid On The Top Of The Plinth. The 12 Mm Thick Plastering Shall Be Done All Around The Plinth In 1:4 Ratio Of Cement And Sand. The Contractor Shall Be Responsible To Complete The Work As Per Direction Of Supervising Engineer. It Including The Cost Of All Material, Labour T&P, Carrier Etc. Required For Proper Completion Of Work. 42 Fabrication & Erection Of Fencing And Construction Of Retaining Wall Around Of 250 Kva Transformers.The Complete 11/0.4 Kv Substation Shall Be Provided With Two Meter Height Fencing And Retaining Wall Around The Substation. One No. Gate With Proper Locking Arrangement For Entry Of Personnel Shall Also Be Provided. The Fencing Shall Be Made Of 50X25 Mm X10 Swg Rectangular Welded Mesh Of Wire Mesh In Length. Wire Mesh Shall Be Fixed On Panels Made Of 50X50X6 Mm M.S. Angle. The Wire Mesh On Panels Will Be Supported By 25X3 Mm M.S. Flat On All The Bracings Diagonally And 50X6 M.S. Flat Horizontally At The Center Of The Panel. The Panel Will Be Joined By Bolts & Nuts Of Appropriate Size With Each Other And On The Main Support On Corners Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work. The Painting Of Complete Fencing Shall Also Be Done With One Coat Of Red Oxide Primer And Two Coat Of Synthetic Green Paint. For Construction Of Retaining Wall Around The Fencing, Excavation Of Earth Shall Be Done In Foundation In Ordinary Soil Including Disposal Of Surplus Earth At Some Suitable Distance. The Dimension Of Excavation Shall Be 1M Wide, 0.45 M Deep And Suitable Length As Per Wire Mesh. After Excavation Of Earth A Cement Concreted Pad Shall Be Laid In Foundation. Concreting Shall Be Done With Ist Class Brick Ballast, Coarse Sand And Cement In Proportion Of 8:4:1. First Class Brickwork Shall Also Be Done In Foundation And Super Structure In 1:6 Cement And Coarse Sand Including Necessary Cutting And Moulding Of Bricks In Foundation Depth Of Wall 0.30 M, Thickness Of Wall 0.35 M & Superstructure Brick Work Thickness Of Wall 0.23 M & Depths 0.30 M Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
31.
Power #11314308 Price Bid
Tender for Installation Of 100 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-I Hapur, Under Edc Hapur (10 No. Work) (Dpr N0. 106, 108, 109, 110, 111, 112, 113, 114, 115 & 116 ) , Safe Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 11.0M Long , 11/0.440 Kv 100 Kva Dt , Acsr Weasel Conductor , Lt Ab Cable 3X120+1X95+1X16 Sqmm , Lt Ab Cable 3X95+1X70+1X16 Sqmm , Lt Pvc Alu. 3.5X150/70 Sqmm , 11Kv Polymeric Pin Insulator With Pin , 11Kv Disc Insulator T&C Type 45 Kn With Fitting , Earthing Complete , Stay Rod , Stay Wire 7/10 Swg. , Erection And Fixing Of Double Pole Structure For Plain Cement Concrete Pole 11 Mtr 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 11 Mtr Supports In cement concrete 1:4:8 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:4:8 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm And M.S. Angle 65X65x6mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , M.S. Channel 100X50x5mm , M.S. Angle 65X65x6mm , Providing And Fixing Of All Types Of Double Pole Clamps Including, Holding Clamps, Top Channel Clamps, Dropper Channel Clamps Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Follwings Petty Meterial As Per As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Suspension Clamps , I-Hook , Peircing Connector , Barbed Wire , 11 Kv Danger Board , Providing & Fixing Of Lt Fuse Set Protection Unit For 100 Kva Dt With Smc Box Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv D.O. Fuse Set Protection Unit For 100 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 11/0.440 Kva 100 Dt With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm Using Suspension Clamps, I-Hook And Dead End Clamp Inculding Jumpering Work With Peircing Connector, Cable Connection With Distribution Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X95+1X70+1X16 Sqmm Using Suspension Clamps, I-Hook And Dead End Clamp Inculding Jumpering Work With Peircing Connector, Cable Connection With Distribution Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Erection And Laying Of Lt Pvc Al 3.5X150/70 Sqmm Inculding Proper Connection With Long Barrel Lug, Proper 3 Nos Crimping On Each Lug, Lt Fuse Set/Smc Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Fixing And Grauting Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Stay Set And Stay Wire Will Be Provided By Department. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Providing And Fixing Of G.I. Strip Of Size 50 Mm × 6 Mm For Connection Of Transformer, Including Cutting, Bending, Drilling, Welding/Bolting, Clamping, And Proper Jointing With Required Nuts, Bolts, Washers, Clamps, And All Necessary Materials, Labour, Tools & Plants For Complete And Satisfactory Execution Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Earthing Of Supports And Neutral Of Dt With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Earthing Of Dt In B.Plan 2026-27 Scheme At Various Site Of Edd-I Hapur, Under Edc Hapur (2 No. Work) (Dpr N0. 57 & 58) , Safe Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Earthing Rod , Gi Wire 6 Swg , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing, Supplying, And Fixing Of Heavy-Duty Nuts And Bolts Of Approved Make And Grade, Complete With Two Numbers Plane Washers And One Number Heavy-Duty Spring Washer Per Assembly, Conforming Strictly To Relevant Is Specifications And Respo Drawing Norms; Scope Of Work Includes Material Supply, Transportation, Precise Positioning, Alignment, And Rigid Tightening To Specified Engineering Torque Limits On Electrical Structures, Steel Poles, Cross-Arms, Or Substation Equipment, Inclusive Of Rust-Preventive Primer/Paint Coatings Where Required, All Handling Labor, Tools, Tackles, Scaffolding, Staging, Leads, And Lifts At Any Height, Executed Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Erection Of Chemical Earthing For Neutral Of Dt With Gi Strip 50X6mm Including Excavation Of Pit And Using Necessary Chemical And Electrode To Obtain Results ≤ 1 Ohm, 3M Apart From Support, Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Strip 50X6 Mm & Earthing Lugs, Nut And Bolts As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Supply And Delivery Of Heavy-Duty 4-Ton Capacity Transformer Handling Trolley (12 X 6) Complete With Tyres, Stabilization Jacks, Mesh Safety Fencing, And Dual Gates As Per Technical Specifications. detail project report 99, 100, 101 , Providing And Safe Delivery Of Heavy-Duty Transformer Handling Trolley Complete In All Respects As Per Approved Specifications And Directions Of Engineer-In-Charge. The Trolley Shall Be Fabricated With Overall Outer Dimensions Of 12 Feet Length × 6 Feet Width Using Heavy-Duty M.S. Structural Sections And Designed For Minimum Load Carrying Capacity Of 4 Tons Without Bending, Deformation, Or Structural Failure. The Platform Shall Have Minimum Structural Depth Of 6 Inches Fabricated With Heavy-Duty M.S. Plates Supported On Rigid Internal Frame Suitable For Handling Static And Dynamic Transformer Loads During Lifting, Shifting, Transportation, And Storage. The Trolley Shall Maintain Uniform Minimum Ground Clearance Of 3.5 Feet From Bottom Of Main Frame To Ground Level And Shall Be Provided With Side Retaining Walls Of Minimum 32 Inches Height Above Platform Level. Complete Safety Fencing Of 6 Feet Height Fabricated With Alloy M.S. Mesh Securely Welded To Structural Frame Along With Continuous 0.5-Foot M.S. Angle Reinforcement At Top Perimeter Shall Be Provided On All Four Sides. One Front Gate And One Rear Gate Each Of Minimum 6 Feet Width Complete With Heavy-Duty Hinges And Locking Arrangement Shall Also Be Provided For Loading And Unloading Purposes. The Main Longitudinal Frame Members Shall Be Fabricated Using 100 Mm × 50 Mm M.S. Channels And Cross Members Using 75 Mm × 40 Mm M.S. Channels Placed At Suitable Spacing For Uniform Load Distribution. The Trolley Shall Be Complete With Axle And Wheel Assembly Comprising Two Nos. Heavy-Duty 65 Mm Dia Steel Axles, Four Nos. Tyres Size 7 × 50 × 16, Four Nos. Heavy-Gauge Steel Rims Size 7 × 50 × 16, Heavy-Duty 36-Inch Bearing Arrangement, And Four Nos. Jack Punches With Chudi Size 12 × 50 Mm Dia At Each Corner For Stabilization During Loading And Unloading Operations. All Fabrication Work Shall Be Carried Out With High-Quality Arc/Co₂ Welding And All Joints Shall Be Properly Finished, Ground Smooth, And Free From Cracks, Porosity, And Defects. The Complete Structure Shall Be Cleaned Thoroughly And Painted With One Coat Of Red Oxide Primer Followed By Two Coats Of Approved Industrial Enamel Paint. All Materials Including M.S. Plates, Channels, Angles, Mesh, Tyres, Rims, Bearings, And Welding Consumables Shall Be Brand New And Conform To Relevant Is Specifications. The Completed Trolley Shall Be Inspected By Competent Authority And Any Defects Shall Be Rectified By Contractor At No Extra Construction The Rate Shall Include Cost Of All Materials, Labour, T&P, Fabrication, Fitting, Welding, Painting, Transportation, Loading, Unloading, Testing, Inspection, And Delivery Complete In Ready-To-Use Condition. Unit: Each (No.).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
32.
Power #11314306 Price Bid
Tender for Installation Of 63 Kva & 100 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (56 No. Work) (Dpr N0. 137,138,141,142,143,144,145,146,147,148,149,150,151,152,153,154,155,156,157,158,159,160,161,152,163,164,165,166,167,168,169,170,172,173,174,175,176,177,178,179,180,181,182,183,184,185,186,187,188,189,190,191,192,193,194,195) , Carriage Of All Petty Material Of All 56 Estimate, (Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 63Kva/100 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Weasel Conductor, From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Lt Abc 3X120+1X95+1X16 Sqmm From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Dropper Channel (56Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 125X65 Sqmm And Febrication Of Top Channel/ Dropper Channel For Fuse Set / T-Off Channel (112Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 125X65x6 Mm And Febrication Of Base Angle For Substation 63Kva/100Kva (112Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 63 Kva/100 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm By Providing Suspension Clamp Dead End Clamp, I-Hook Etc And Completion Work Properly, As Per Respo Norms, And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60Xo.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv. Fuse Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Lt Fuse Set Protection Unit For 100 Kva Tf With Smc Box Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of 3-Phase Distributiong Box All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Installation Of 250 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (02 No. Work) (Dpr No. 140 & 171) , Carriage Of All Petty Material Of 02 Estimate, (, Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 250 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Dropper Channel(4Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 125X65 Sqmm And Febrication Of Top Channel/ Dropper Channel For Fuse Set / T-Off Channel (4Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Safely Installation Of 250 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth, As Per Direction Of Site Incharge. , Laying Of Lt Pvc Cable Al 1X400 Sqmm By Porviding Al Lug And Panching With Cremping Tool Complection Work Properly, As Per Respo/Norms And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Construction Of Tif Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mt.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Erection & Fixing Of 11Kv. Fuse Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Construction Of Safety Fencing (Ms) For Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50mm) 4 Sqmm Dia M.S. Gi Wire Mess Corrosion Free Made Of Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Anglen-Iron To Be Fitted On Vertical Posts. Pickets (I Required) Fitted To Rail And Gate To Facilitate Entry And Exit With Lock. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Gi Angle 75X75x6 Mm Corrosion Free. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Metalic Materilas Should Be Galvanized & Corrosion Free) , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Propviding And Intallation All Requrment For Earthing Of Neutral By Boring And Lowering Of G.I. Pipe Size 32 Mm Dia... Into The Ground Up To Water Level 80 Fit. With The Lower End Of Solid Copper Cone Approx. 225Mm Long And 750 Gm. In Weight Shall Be Provided And In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg From The Cone Up To The Ground Surface Where It Will Bc Bolted To The Nf.S. Earth Strip For Tif Neutral Connection, The Earth Strip *Vill Be Welded To The G.L. Pipe And Neutral Earthing Support, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Capacity Increasing 10/16 Kva To 25 Kva Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (18 No. Work) (Dpr No. 740,741,742,743,744,745,746,747,748,749,750,751,752,771,773,833,834 & 891) , Carriage Of All Petty Material Of 18 Estimate, (Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 25 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Weasel Conductor, From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Erection Of Single Pole Structure With Exsiting Single Pole And Making It Double Pole All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Top Channel/Dropper Channel(36Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 125X65x6 Mm And Febrication Of Base Angle For Substation 25Kva (36Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 25 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Safely Removal Of Old & Used 10/16 Kva Transformer With The Help Of Crane/Manual Labour From Lt Sub-Station Double Pole/Plinth And Carrige Site To Store Hapur As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Specification, Quantity And Price Schedule For Replacement Of 33Kv Line Jindal Nagar Jarjar Line And Feeder Bifurcation 1Ikv Feeder No- 1 Reliance Road In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Pilkhuwa Under Edc Hapur. (02 No. Work) (Dpr No. 70 & 16) , Carriage Of All Petty Material Of 02 Estimate From Electricity Store Center Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Dog Conductor Of Estimate From Je Store/Ctr/Esc Hapur To Site Of Work, Including Loading & Unloading At Both Ends, As Per Direction Of Site Incharge. , Carriage Of All Type Cable Of Estimate From Je Store/Ctr/Esc Hapur To Site Of Work, Including Loading & Unloading At Both Ends, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 11 Mtrs. Long From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 11 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Angle, E-Bracket, 11Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Nomrs By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Jumpering Etc Work And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, Fixing Of M.S. Top & Dropper Channel, M.S. Angle, E-Bracket, 11Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Nomrs By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Jumpering Etc Work And As Per Direction Of Site Incharge. , Erection & Fixing Of Single Plain Cement Concrete Pole 8.50 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing/Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm, Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Top Channel/Dropper Channel/T-Off Channel/Bracket Channel Suitable For Dp/Single Pole For Pcc/Stp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 65X65x6 Mm And Febrication Of Bracket /Bracing Angle Suitable For Dp/Single Pole For Pcc/Stp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of Single Plain Cement Concrete Pole 11 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing/Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, As Per Direction Of Site Incharge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor By Providing Holding Clamp, Nut & Bolt E-Bracet If Reqired As Per Respo/Drnwing Nonns And As Per Direction Of Site Incharge , Grouting & Fixing Of Stay Rods (20Xl800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30) M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I.Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of Plain Cement Concrete Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 33 Kv 3X300 Sq.Mm Xlpe Cable And Lt Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11 Kv Cable Jointing Kit 3X185 Sqmm, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , Making And Fixing Of Side Breckit By Ms. Channel, Ms Angle By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Erecetion Of 11 Kv V-Type Crross Arm By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Providing And Trcnchless Laying (90X2=180 Mtrs. Double Circuit) Of 140/160Mm O/D Pn-4Pe-80 Pn-4 Grade Uv Stabilized Hdpe Pipe As Per Is Of 6 Meter, For Laying Of Underground Cable As Per Respo/Norms, Including Cost Of Above Hdpe Pipe, Es Per Direction Of Site Incharge. , Laying Of 11 Kv Xlpe Cable 3X185 Sqmm, Undergound (110X2=220 Mtrs. Double Circuit) Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape Al Both Ends As Per Respo/Norms And As Per Direction Of Site Incharge , Providing And Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Clamps, Nuts & Bolts Etc.) As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Barbed Wire, As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Stone Pad 300X300x75 Mm, As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Number Plate As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Pg Clamp, As Per Respo/Norms And As Per Direction Of Site Incharge. , Errection Of Brecing Set 4.3X4.3 Mtr Angle Iron 65X65x6 Mm By Providing Holding Clamp, Nut & Bolt As Per Respo/Norms And As Per Direction Of Site Incharge. , Dismantling Of Existing 33 Kv Line And Jarjar Conductor And And Bundling Same Including Carriage Of Above Material Form Site Of Work To Je Store/Esc-Hapur, With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo/Norms And As Per Direction Of Site Incharge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
33.
Power #11314305 Price Bid
Tender for 11 Kv Line Bifercation Amba Panel Industrial In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. (01 No Work) detail project report 71 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Dog Conductor , 11 Kv completion Poly. Pin Insulator , Stay Set , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Vcb Outgoing , Gi X-Arm Angle , 11 Kv Cable Box O/D Type Size 3X120 Sq.Mm , 11 Kv Ht Xlpe Cable 3X120 Sq.Mm. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets, Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works For Proper Completion Of Work As Directed By The Engineer-In-Charge , Grouting And Fixing Of Stay Rod Of Size 20 × 1800 Mm Complete In All Respects, Including Excavation, Providing And Laying Cement Concrete Of Size 0.60 × 0.60 × 0.30 M In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast), Backfilling, Proper Ramming, Fixing, Tightening And Nozzling Of Stay Wire With Stay Rod And Pole To The Required Tension As Per Respo Drawings/Norms, Including Providing And Fixing Stay Clamp Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts, Bolts And Loops, And All Labour, Tools & Plants And Grouting Material As Directed By The Engineer-In-Charge. , Making And Filling Of 11 Kv Xlpe Cable Jointing Kit Suitable For 3 × 120 Sq.Mm Cable, Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Engineer-In-Charge. , Installing, Testing And Commissioning Of 11 Kv Vcb Outgoing Panel Complete In All Respects, Including Mounting, Alignment, Interconnection, Control Wiring, Earthing, Nuts, Bolts, Clamps And All Associated Accessories, Labour, Tools & Plants Required For Proper Installation And Satisfactory Operation As Per Approved Drawings, Departmental Specifications And Directions Of The Engineer-In-Charge , Providing, Fabricating And Fixing Of Side Bracket Made Of M.S. Channel And M.S. Angle, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, Complete In All Respects As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work.. , Erection Of 11 Kv V-Type Cross Arm Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Erection Of 11 Kv Pin Insulator Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Erection Of 11 Kv Disc Insulator With Fittings Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of T-Off Clamp Complete With Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms/Approved Drawings, Including All Labour, Tools & Plants Required For Proper Installation And Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , 33 Kv Line Strengthing In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. (03 No Work) 17,18,19 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Acsr Dog Conductor , Earth Rod , 33 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 11 Mtr. , Stay Set , Stay Wire , Gi Wire 4Mm/8Swg , 33 Kv Cross Arm 100X50 Mm , 33 Kv Cable Box O/D Type Size 3X300 , 33 Kv Xlpe Cable Type Size 3X300 Sq.Mm. , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , 33 Kv completion Poly. Pin Insulator , Stay Wire , Gi Wire 4Mm/8Swg , Erection And Fixing Of Single Plain Cement Concrete Pole, 11 Mtr Long, For 11 Kv Line Complete In All Respects, Including Digging Of Suitable Pit, Positioning, Alignment, Dressing And Fixing Of Requisite Accessories As Per Respo Drawings/Norms, Including Providing And Fixing Of F-Bracket Made Of M.S. Flat Of Size 50 × 6 Mm, Holding Clamps Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts And Bolts, And All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting And Fixing Of Stay Rod Of Size 20 × 1800 Mm Complete In All Respects, Including Excavation, Providing And Laying Cement Concrete Of Size 0.60 × 0.60 × 0.30 M In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) As Per Drawing, Backfilling, Proper Ramming And Allied Civil Works, Including Fixing, Tightening And Nozzling Of Stay Wire With Stay Rod And Pole To The Required Tension As Per Respo Drawings/Norms, Including Providing And Fixing Stay Clamp Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts, Bolts And Loops, And All Grouting Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Earthing Of Supports With M.S. Earth Rod Of Size 20 × 2540 Mm Complete In All Respects, Including Excavation Of Pit, Driving Of M.S. Rod At A Distance Of 3.0 M From The Support And 0.5 M Below Ground Level, And Connection Of Support With Earth Electrode Using Suitable Size G.I. Wire And Earthing Lugs, Including Providing And Fixing Of Proper Size Nuts, Bolts And All Associated Accessories, As Per Respo Drawings/Norms, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting Of Plain Cement Concrete Supports Complete In All Respects With Cement Concrete In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) In Block Size 450 × 450 Mm Up To 1/6Th Of The Full Length Of Support Below Ground Level, Including Providing 300 Mm Plinth Above Ground Level With Cement Concrete In Ratio 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Grit) With Proper Mufting As Per Approved Drawing, Including Backfilling, Proper Ramming And Providing All Required Grouting Materials, Labour, Tools & Plants For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of 6 Inch Dia Class-B G.I. Pipe Over 33 Kv 3 × 300 Sq.Mm Xlpe Cable And Lt Xlpe Cable Before Mounting On Double Pole Structure, Complete In All Respects, Including Providing And Fixing Of Suitable Clamps, Sealing Of Top And Bottom Ends Of Pipe, Burying One End Of Pipe Approximately 500 Mm Below Ground Level, Mounting And Clamping Of Cable On Double Pole Structure, And Making Connection With Overhead Line At Both Ends, Including All Labour, Tools & Plants And Associated Materials Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Making And Filling Of 33 Kv Xlpe Cable Jointing Kit Suitable For 3 × 300 Sq.Mm Cable Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Erection Of 33 Kv V-Type Cross Arm Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Trenchless Laying Of 200 Mm O/D Pe-80, Pn-4 Grade Uv Stabilized Hdpe Pipe Conforming To Relevant Is Specifications In Standard 6 Mtr Length For Laying Of Underground Cable, Complete In All Respects As Per Respo Norms, Including Cost Of Hdpe Pipe, Jointing, Handling, Labour, Tools & Plants And All Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Laying Of 33 Kv Xlpe Cable Of Size 3 × 300 Sq.Mm Underground Through Hdpe Pipe Complete In All Respects, Including Pulling, Dressing, Alignment And Leaving Spare Cable In Loop Shape At Both Ends As Per Respo Norms, Including All Labour, Tools & Plants And Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Holding Clamp Complete In All Respects, Including Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms/Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Jumpering And Line Energisation Work Complete In All Respects, Including Proper Connection, Tightening, Testing And Commissioning As Per Respo Norms/Approved Drawings, Including All Labour, Tools & Plants And Associated Materials Required For Safe And Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Safe De-Erection And Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , 11 Kv Line Strengthing In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. (11 No Work) detail project report 61,62,63,64,65,66,67,68,69,70,71 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Earth Rod , 11 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 8.5 Mtr. , Plain Cement Concrete Pole 11 Mtr. , Stay Set , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Gi Wire 10Swg , Gi X-Arm Angle , 11 Kv Vtype Steel Cross Arm , 33 Kv Cable Box O/D Type Size 3X300 , 11 Kv Cable Box O/D Type Size 3X120 Sq.Mm , 33 Kv Xlpe Cable Type Size 3X300 Sq.Mm. , 11 Kv Ht Xlpe Cable 3X120 Sq.Mm. , 11 Kv Xlpe Cable 3X300 Sq.Mm. , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Disc Fitting 45 Kn , 11 Kv completion Poly. Pin Insulator , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Gi Wire 10Swg , Gi X-Arm Angle , 33 Kv Xlpe Cable Type Size 3X300 Sq.Mm. , 11 Kv Ht Xlpe Cable 3X120 Sq.Mm. , Erection And Fixing Of Single Plain Cement Concrete Pole, 8.50 Mtr Long, For 11 Kv Line Complete In All Respects, Including Digging Of Suitable Pit, Positioning, Alignment And Fixing Of Requisite Accessories As Per Respo Drawings/Norms, Including Providing And Fixing Of F-Bracket Made Of M.S. Flat Of Size 50 × 6 Mm And Holding Clamps Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts And Bolts, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Weasel Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Rabbit Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting And Fixing Of Stay Rod Of Size 20 × 1800 Mm Complete In All Respects, Including Excavation, Providing And Laying Cement Concrete Of Size 0.60 × 0.60 × 0.30 M In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) As Per Approved Drawing, Including Backfilling, Proper Ramming And Allied Works, Fixing, Tightening And Nozzling Of Stay Wire With Stay Rod And Pole To The Required Tension As Per Respo Drawings/Norms, Including Providing And Fixing Stay Clamp Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts, Bolts And Loops, And All Grouting Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Earthing Of Supports With M.S. Earth Rod Of Size 20 × 2540 Mm Complete In All Respects, Including Excavation Of Pit, Driving Of M.S. Rod At A Distance Of 3.0 M From The Support And 0.5 M Below Ground Level, And Connection Of Support With Earth Electrode Using Suitable Size G.I. Wire And Earthing Lugs, Including Providing And Fixing Of Proper Size Nuts, Bolts And All Associated Accessories, As Per Respo Drawings/Norms, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting Of Plain Cement Concrete Supports Complete In All Respects With Cement Concrete In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) In Block Size 450 × 450 Mm Up To 1/6Th Of The Full Length Of Support Below Ground Level, Including Providing 300 Mm Plinth Above Ground Level With Cement Concrete In Ratio 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Grit) With Proper Mufting As Per Approved Drawing, Including Backfilling, Proper Ramming And Providing All Required Grouting Materials, Labour, Tools & Plants For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of 6 Inch Dia Class-B G.I. Pipe Over 33 Kv 3 × 300 Sq.Mm Xlpe Cable And Lt Xlpe Cable Before Mounting On Double Pole Structure, Complete In All Respects, Including Providing And Fixing Of Suitable Clamps, Sealing Of Top And Bottom Ends Of Pipe, Burying One End Of Pipe Approximately 500 Mm Below Ground Level, Mounting And Clamping Of Cable On Double Pole Structure, And Making Connection With Overhead Line At Both Ends, Including All Labour, Tools & Plants And Associated Materials Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Making And Filling Of 33 Kv Xlpe Cable Jointing Kit Suitable For 3 × 300 Sq.Mm Cable Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Making And Filling Of 11 Kv Xlpe Cable Jointing Kit Suitable For 3 × 120 Sq.Mm Cable Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Providing, Fabricating And Fixing Of Side Bracket Made Of M.S. Channel And M.S. Angle Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Erection Of 33 Kv V-Type Cross Arm Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Trenchless Laying Of 200 Mm O/D Pe-80, Pn-4 Grade Uv Stabilized Hdpe Pipe Conforming To Relevant Is Specifications In Standard 6 Mtr Length For Laying Of Underground Cable, Complete In All Respects As Per Respo Norms, Including Cost Of Hdpe Pipe, Jointing, Handling, Labour, Tools & Plants And All Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying Of 11 Kv Xlpe Cable Of Size 3 × 125 Sq.Mm Underground Through Hdpe Pipe Complete In All Respects, Including Pulling, Dressing, Alignment And Leaving Spare Cable In Loop Shape At Both Ends As Per Respo Norms, Including All Labour, Tools & Plants And Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying Of 33 Kv Xlpe Cable Of Size 3 × 300 Sq.Mm Underground Through Hdpe Pipe Complete In All Respects, Including Pulling, Dressing, Alignment And Leaving Spare Cable In Loop Shape At Both Ends As Per Respo Norms, Including All Labour, Tools & Plants And Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Danger Board Complete In All Respects, Including Providing And Fixing Of All Required Accessories Such As Suitable Clamps, Nuts, Bolts And Allied Materials, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Stone Pad Of Size 300 × 300 × 75 Mm Complete In All Respects, As Per Respo Norms And Approved Drawings, Including Excavation, Dressing, Leveling, Proper Positioning, Packing And Fixing With All Labour, Tools & Plants And Associated Materials Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of F-Clamp Complete In All Respects, Including Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Holding Clamp Complete In All Respects, Including Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Top Channel Of Approved Make And Required Dimensions Conforming To Respo Norms And Specifications; Work Includes Material Supply, Transport, Unloading, Cutting To Size, Hoisting, Alignment, And Rigidly Securing In Position With Approved Fasteners, Hardware, And Scaffolding At Any Height Or Location, Complete In All Respects As Per The Manufacturers Guidelines And To The Entire Satisfaction And Direction Of The Site In-Charge. , Providing And Fixing G.I. Barbed Wire Fencing Of Approved Make, Weight, And Gauge Conforming Strictly To Respo Norms And Standard Technical Specifications; Work Includes Supplying, Transporting, And Unrolling Required Lines Of Horizontal And Diagonal Strands, Tightly Stretching, Aligning, And Securely Fixing To Concrete/Steel/Stone Posts Using Approved G.I. Staples, Binding Wire, Or Fasteners, Including All Leads, Lifts, Necessary Scaffolding, Tools, Tackles, And Labor Required To Complete The Installation In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Fixing M.S. / G.I. / High-Tensile Nut And Bolt Assemblies Of Approved Make, Grade, And Required Diameters/Lengths Conforming Strictly To Respo Norms And Standard Technical Specifications; Work Includes Supply, Transport, Positioning, Aligning, And Rigidly Tightening To The Specified Torque Using Appropriate Washers (Plain/Spring) And Tools, Including All Necessary Scaffolding, Labor, Leads, And Lifts Required To Complete The Fastening Work In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Erection Of Structural Steel Bracing Sets Of Size 4.3 M X 4.3 M Fabricated From M.S. Angle Sections Of Size 65 Mm X 65 Mm X 6 Mm, Conforming Strictly To Respo Norms And Technical Specifications; Work Includes Hoisting, Lifting, Proper Positioning, Leveling, Aligning, And Rigidly Securing The Assembly Using Approved Holding Clamps, Structural Nuts, Bolts, And Washers Of Required Sizes, Including The Cost Of All Fastening Hardware, Necessary Tools, Tackles, Scaffolding, Staging, Leads, Lifts, And Labor Required To Complete The Installation In All Respects As Per Standard Engineering Practices And Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , 33 Kv Protection Of Sub-Station In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur.(01 No Work) detail project report 39 , Carriage Of 33 Kv Vcb From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Carriage Of 33 Kv Ct Out Door From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , 33 Kv Installation Of Vcb , 33 Kv Installation Of Ct Outdoor , Providing & Making And Fixing Of Side Breckit By Ms. Channel, Ms Angle By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Erecetion Of 11 Kv Disc Insulator With Fitting By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Providing And Fixing Of Copper Control Cable Size 2X2.25 Sq.Mm. , As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing, Installing, Testing, And Commissioning Of Maintenance-Free Water Level Chemical Earthing System Conforming To Is:3043 Specifications For Distribution Transformers And Substations; Scope Includes Boring An Earth Pit Of Required Depth, Inserting A Heavy-Duty Copper-Bonded Steel Electrode Or Gi Pipe (Minimum 3-Meter Length), Backfilling The Pit With Eco-Friendly Moisture-Retaining Earth Enhancement Chemical Compound, Providing A Dedicated Funnel Arrangement With A Perforated Gi Watering Pipe Running To The Root Of The Electrode For Manual Moisture Replenishment, Constructing A Rigid Brick Masonry/Pre-Cast Concrete Inspection Chamber With A Heavy-Duty Removable Cover Plate At Ground Level, And Establishing Secure Structural Connections To The Equipment Earth Grid Using Proper Size Gi/Copper Strips, Inclusive Of All Excavation In Any Soil Strata, Backfilling, Ramming, Hardware, Labor, Tools, Tackles, And Transportation, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Providing And Fixing Of Ms Channel As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Ms Angle As Per Respo/Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo/Norms And As Per Direction Of Site Incharge. , 33 Kv Vcb In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. ( 07 No Work) detail project report 20,21,22,23,24,25,26 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , 33 Kv Ct Outdoor Ctr 200/100/1 , Control Pannel 33 Kv Double T/F , 33 Kv Outdoor Type Vcb , Providing, Fabricating, And Fixing M.S. Side Brackets Of Required Design And Dimensions, Utilizing Approved M.S. Channel And M.S. Angle Sections, Conforming Strictly To Respo Norms And Standard Technical Specifications; Scope Of Work Includes Material Supply, Cutting, Welding, Drilling, Rust-Preventive Primer Coating, Hoisting, Proper Alignment, And Rigidly Securing The Brackets In Position Using Appropriate Holding Clamps, Nuts, Bolts, And Washers, Inclusive Of All Necessary Staging, Scaffolding, Tools, Tackles, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Testing, And Commissioning Of Pvc/Xlpe Insulated, Pvc Sheathed 2 Core X 2.25 Sq.Mm. Copper Control Cable (Armored/Unarmored) Of Approved Make And Grade, Conforming Strictly To Respo Norms And Relevant Is Specifications; Work Includes Supply, Transportation, Storage, Unrolling, Straightening, And Laying Of Cable Through Existing Pipes, Conduits, Cable Trays, Or Trenches, Including Dressing, Clamping, Structural Clipping, Proper Tag Identification, End-Termination Using Required Size Copper Lugs, Glands, Glands-Earthing, And Testing (Insulation Resistance And Continuity Tests), Inclusive Of All Labor, Tools, Tackles, Scaffolding, Leads, And Lifts, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Testing, And Commissioning Of Pvc/Xlpe Insulated, Pvc Sheathed 4 Core X 2.25 Sq.Mm. Copper Control Cable (Armored/Unarmored) Of Approved Make And Grade, Conforming Strictly To Respo Norms And Relevant Engineering Specifications; Work Includes Supply, Transportation, Storage, Unrolling, Straightening, And Laying Of Cable Through Existing Pipes, Conduits, Cable Trays, Or Trenches, Including Systematic Dressing, Clamping, Structural Clipping, Proper Tag Identification, End-Termination Using Required Size Copper Lugs, Glands, Glands-Earthing, And Necessary Testing (Insulation Resistance And Continuity Tests), Inclusive Of All Labor, Tools, Tackles, Scaffolding, Staging, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Construction Of Vacuum Circuit Breaker (Vcb) Plinth Of Size 2.0 M X 2.0 M X 1.5 M Suitable For A 250 Kva Transformer/System, Executed Strictly As Per Approved Structural Drawings And Respo Norms; Work Includes Excavation, Providing And Laying Cement Concrete (Cc) 1:4:8 (1 Cement : 4 Sand : 8 Graded Brick Ballast) In Foundation, Constructing Side Walls Using 1St Class Brickwork In Cement Mortar 1:4 (1 Cement : 4 Fine Sand), Applying 12 Mm Thick Cement Plaster 1:4 (1 Cement : 4 Fine Sand) On Exposed Surfaces, Backfilling Inside The Plinth With Brick Ballast Including Systematic Watering And Heavy Ramming/Compaction, And Casting A Finished Reinforced Cement Concrete (Rcc) Top Slab In 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Including Necessary Reinforcement Steel, Shuttering, Centering, And Curing; Rate Shall Be Fully Inclusive Of All Material Supply, Transport, Machinery, Scaffolding, Labor, Leads, And Lifts, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Testing, And Commissioning Of Pvc/Xlpe Insulated, Pvc Sheathed 6 Core X 2.25 Sq.Mm. Copper Control Cable (Armored/Unarmored) Of Approved Make And Grade, Conforming Strictly To Respo Norms And Relevant Engineering Specifications; Work Includes Supply, Transportation, Storage, Unrolling, Straightening, And Systematic Laying Of Cable Through Existing Pipes, Conduits, Cable Trays, Or Trenches, Including Dressing, Clamping, Structural Clipping, Proper Tag Identification, End-Termination Using Required Size Copper Lugs, Compression Glands, Glands-Earthing, And Mandatory Pre-Commissioning Testing (Insulation Resistance And Continuity Tests), Inclusive Of All Labor, Tools, Tackles, Scaffolding, Staging, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Propviding And Intallation All Requrment For Earthing Of Neutral By Boring And Lowering Of G.I. Pipe Size 32 Mm Dia... Into The Ground Up To Water Level 80 Fit. With The Lower End Of Solid Copper Cone Approx. 225Mm Long And 750 Gm. In Weight Shall Be Provided And In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg From The Cone Up To The Ground Surface Where It Will Bc Bolted To The Nf.S. Earth Strip For Tif Neutral Connection, The Earth Strip *Vill Be Welded To The G.L. Pipe And Neutral Earthing Support, As Per Direction Of Site Incharge. , Installation Of 100 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Garh, Under Edc Hapur (No. Of Work 5) 121,122,123,124,128 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Weasel Conductor , Earth Rod , A.B Cable L.T (3X120+1X95+1X16) Sq Mm , D.O Fuse Set , 11 Kv Tpmo Switch , 11 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 8.5 Mtr. , Plain Cement Concrete Pole 11 Mtr. , Stay Set , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Lt Alu. Xlpe Cable 3.5X150 Sq. Mm , Gi Wire 4Mm/8Swg , Gi X-Arm Angle , 100 Kva Transformer , Lt Xlpe Cable 3.5X150 Sq.Mm. , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Disc Fitting 45 Kn , 11 Kv completion Poly. Pin Insulator , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Lt Alu. Xlpe Cable 3.5X150 Sq. Mm , Gi Wire 4Mm/8Swg , Gi X-Arm Angle , Lt Xlpe Cable 3.5X150 Sq.Mm. , Erection Of Double Pole (Dp) Structure Utilizing 8.5-Meter Long Plain Cement Concrete Poles, Complete With All Necessary Structural Accessories And Conforming Strictly To Approved Respo Drawings And Norms; Work Includes Excavation, Pole Erection, Alignment, Backfilling, And Fabrication, Supply, And Fixing Of M.S. Top And Dropper Channels, M.S. Tif Angles, And E-Brackets; Installation Of 11 Kv Pin Insulators With Pins And Disc Insulators With Appropriate Hardware/Disc Fittings; Providing And Fixing Structural Stays, Bracings, And Assemblies Fabricated From M.S. Flat Of Size 50 Mm X 6 Mm, Secured Tightly With Proper Size Nuts, Bolts, And Washers; Execution Of Complete Standard Jumpering, Binding, And Pg Clamping Work Using Appropriate Conductors/Accessories To Ensure Electrical Continuity; Rate Shall Be Fully Inclusive Of All Structural Steel, Hardware, Insulation Materials, Machinery, Tools, Tackles, Scaffolding, Labor, Leads, And Lifts At Any Height, Complete In All Respects As Per Standard Engineering Practices Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Erection Of Double Pole (Dp) Structure Utilizing 11-Meter Long Plain Cement Concrete Poles, Complete With All Structural Accessories And Conforming Strictly To Approved Respo Drawings And Norms; Work Includes Excavation, Pole Erection, Leveling, Alignment, And Backfilling; Fabrication, Supply, And Fixing Of M.S. Top And Dropper Channels, M.S. Tf Angles, And E-Brackets; Installation Of 11 Kv Pin Insulators With Pins And Disc Insulators With Appropriate Hardware/Disc Fittings; Providing And Fixing Structural Bracings, Ties, And Support Assemblies Fabricated From M.S. Flat Of Size 50 Mm X 6 Mm, Secured Tightly With Proper Size Nuts, Bolts, And Washers; Execution Of Complete Standard Jumpering, Binding, And Pg Clamping Work Using Appropriate Conductors To Ensure Reliable Electrical Continuity; Rate Shall Be Fully Inclusive Of All Structural Steel Fabrication, Hardware, Insulation Components, Handling Machinery, Tools, Tackles, Scaffolding, Labor, Leads, And Lifts At Any Height, Complete In All Respects As Per Standard Electrical Engineering Practices Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Laying Stone Pad Base Blocks Of Size 300 Mm X 300 Mm X 75 Mm Of Approved Quality And Strength, Conforming Strictly To Respo Drawings And Norms; Work Includes Supply, Transportation, Storage, Necessary Excavation Or Surface Preparation, Leveling, And Dressing Of Soil, Proper Positioning, Rammed Leveling, And Alignment Of The Stone Pads Beneath Poles, Structures, Or Stays To Act As A Solid Bearing Foundation, Including The Cost Of All Materials, Machinery, Tools, Tackles, Handling Labor, Leads, And Lifts At Any Location, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Fixing Heavy-Duty M.S. Holding Clamps Fabricated To Required Profiles And Dimensions, Complete With Matching Nut, Bolt, And Washer Assemblies Of Approved Make And Size, Conforming Strictly To Respo Drawings And Norms; Work Includes Material Supply, Transport, Proper Positioning Around Poles, Structures, Or Machinery, Alignment, And Rigid Fastening/Tightening To Specified Torque, Inclusive Of All Anti-Corrosive Primer/Paint Coatings, Necessary Tools, Tackles, Scaffolding, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Fixing Heavy-Duty M.S. Clamps Fabricated To Required Design, Shape, And Dimensions, Complete With Appropriate Size Nut, Bolt, And Washer Assemblies Of Approved Make, Conforming Strictly To Respo Drawings And Norms; Work Includes Material Supply, Transportation, Precise Positioning, Alignment, And Rigid Tightening Around Poles, Structural Members, Or Equipment, Inclusive Of Rust-Preventive Primer And Paint Coatings, All Necessary Tools, Tackles, Scaffolding, Staging, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Safe Handling, Lifting, Positioning, And Installation Of A 100 Kva Distribution Transformer Onto An Existing Lt Sub-Station Double Pole Structure Or Concrete Plinth, Utilizing An Appropriate Capacity Crane, Mechanical Hoists, Or Manual Labor With All Safety Equipment; Work Includes Proper Alignment, Leveling, Structural Securing, And Providing And Crimping Appropriate Sizes Of Heavy-Duty Aluminium Long Barrel Lugs For All Ht (High Tension) And Lt (Low Tension) Terminal Connections To Ensure Low-Resistance Termination, Inclusive Of All Handling Machinery, Rigging Tools, Safety Tackles, Scaffolding, Specialized Labor, Leads, And Lifts At Any Height, Executed Complete In All Respects As Per Standard Electrical Engineering Practices And Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Stringing, Testing, And Commissioning Of Xlpe Insulated Lt Aerial Bunched Cable (Abc) Of Size 3X120 + 1X95 + 1X16 Sq.Mm. (Comprising Three Phase Conductors, One Insulated Messenger Wire, And One Street Light Conductor) Of Approved Make, Conforming Strictly To Respo Norms And Relevant Standard Specifications; Work Includes Unrolling, Straightening, Hoisting, And Tensioning Of The Cable Along Poles/Structures Using Appropriate Sagging Equipment, Providing And Fixing Necessary Hardware Including Suspension Clamps, Dead-End/Anchoring Clamps, I-Hooks, Pole Brackets, Stainless Steel Strapping With Buckles, And Insulation Piercing Connectors (Ipcs) For Jointing Or Tapping; Scope Covers Proper Dressing, Securing, And Mid-Span Clamping To Maintain Standard Clearances, Inclusive Of All Machinery, Winches, Pulling Tackles, Scaffolding, Safety Gear, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60Xo.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Fuse/Do Fuse Set Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Lt Fuse Set Protection Unit For 100 Kva Tf With Smc Box Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Tpmo Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Ms Angle & Ms Channel All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Ms Channel , Ms Angle , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Installation Of 250 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Garh, Under Edc Hapur 117, 118, 119,120, 125, 126, 127 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Weasel Conductor , Earth Rod , A.B Cable L.T (3X120+1X95+1X16) Sq Mm , D.O Fuse Set , 11 Kv Tpmo Switch , 250 Kva 11/0.4 Kv Transformer New , 11 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 8.5 Mtr. , Plain Cement Concrete Pole 11 Mtr. , Stay Set , 11 Kv completion Poly. Disc Insulator 45 Kn , Lt Alu. Xlpe Cable 3.5X400 Sq. Mm , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Disc Fitting 45 Kn , 11 Kv completion Poly. Pin Insulator , 11 Kv completion Poly. Disc Insulator 45 Kn , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 11 Mtr. Long, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Safely Installation Of 250 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth, As Per Direction Of Site Incharge. , Laying Of Lt Alu. Xlpe Cable Al. 3.5X400 Sqmm By Porviding Al Lug And Panching With Cremping Tool Complection Work Properly, As Per Respo/Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm By Providing Suspension Clamp Dead End Clamp, I-Hook Etc And Completion Work Properly, As Per Respo Norms, And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60Xo.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Construction Of Tf Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mt.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Construction Of Safety Fencing (Ms) For Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Anglen-Iron To Be Fitted On Vertical Posts. Pickets (I Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 75X75x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Fuse/Do Fuse Set Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Tpmo Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Holding Clamp With Nut & Bolt As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Alu. Lug 240 Sq.Mm.(Ls) Off Size As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing, Installing, Testing, And Commissioning Of Heavy-Duty Tail-Less Fuse Units (Lt Distribution/Bushing Bars) Of Approved Make, Rating, And Specifications Conforming Strictly To Respo Norms And Standard Electrical Designs; Work Includes Material Supply, Hoisting, Proper Alignment, Mounting Onto The Distribution Transformer Lt Bushings Or Dp Structure Steelwork, Making Solid, Low-Resistance Direct Connections, And Providing All Necessary Copper/Aluminium Links, Hardware, Nuts, Bolts, And Washers, Inclusive Of All Safety Gear, Specialized Labor, Tools, Tackles, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing & Fixing Of Ms Angle & Ms Channel All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing, Installing, Testing, And Commissioning Of Maintenance-Free Chemical Earthing System Of Approved Make And Design, Conforming Strictly To Respo Norms, Is 3043, And Ieee 80 Standards; Work Includes Augering/Boring An Earth Pit Of Required Diameter And Depth, Supplying And Lowering A High-Conductivity Copper-Bonded Steel / G.I. Earth Electrode Of Specified Length And Diameter, Completely Backfilling The Surrounding Void With Moisture-Retaining, Non-Corrosive Earth Enhancement Chemical Compound (Bentonite/Carbon Based) Mixed With Water As Per Manufacturer Guidelines, Constructing A Brick Masonry / Pre-Cast Concrete Inspection Chamber With A Heavy-Duty Ci/Concrete Cover Plate On Top, Providing An Integrated Copper/G.I. Terminal Busbar With Required Hardware For Down-Conductor Connectivity, And Conducting Final Earth Resistance Testing To Ensure Values Remain Well Within Permissible Electrical Limits, Inclusive Of All Excavation, Materials, Labor, Tools, And Tackles, Complete Under The Direction And Entire Satisfaction Of The Site In-Charge. , Propviding And Intallation All Requrment For Earthing Of Neutral By Boring And Lowering Of G.I. Pipe Size 32 Mm Dia... Into The Ground Up To Water Level 80 Fit. With The Lower End Of Solid Copper Cone Approx. 225Mm Long And 750 Gm. In Weight Shall Be Provided And In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg From The Cone Up To The Ground Surface Where It Will Bc Bolted To The Nf.S. Earth Strip For Tif Neutral Connection, The Earth Strip *Vill Be Welded To The G.L. Pipe And Neutral Earthing Support, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
35.
Communications and Information Technology  #11297550 AOC
Bids Are Invited For Integration Of Existing Transformers At Mini Data Centre Ernakulam Sitc Of Acb Panel , Dismantling Section Of The Existing 800 A Bus Trunking , Rerouting And Reinstallation Of A Section Of Bus Trunking , Supply And Fixing 3 Mm Thick Ms Sheet , Supply And Fixing Mechanical Interlocking Arrangement With Lockable Trip Push Button Key , Making Necessary Modification In The Existing 800 A Main Lt Panel Bus Bar Arrangement , Supply , Fixing, Testing Of Multifunction Meter , Supply And Fixing Led Type Ryb Indicating L S , Dismantling The Existing Apfc Panel , Supplying And Fixing Fire Retardant Electrically Insulated, Synthetic Mat , Sitc Of 4.5 Kg Co2 Type Fire Extinguisher , Sitc Of 5 Kg Dcp Type Fire Extinguisher , Supply And Fixing Of Gi Fire Buckets , Providing And Laying 6Mm Thick Ms Chequered Sheet , Complete Painting Of The Existing Rusted Chequred Plates , Preparing The Single Line Diagram Of 2X400kva Ht Substation , Supply And Fixing The Signage , Removing The Sand In Fire Buckets , Supply And Fixing 18 W, 4 Feet Led Batten Tube Light Fitting , Complete Cleaning Of The Existing Substation Room , Supplying And Fixing 15 Or 16 A Switch And 6 Pin 15 Or 16 Socket Outlet On Metal Box , Supplying, Installation Including Suspension, Testing And Commissioning Of 800 S Bus Trunking , Supplying Of 3.5 C X 400 Sq.Mm Cable , Supplying Of 3.5 C X 300 Sq.Mm Cable , Laying Of One Number Pvc Insulated Power Cable In Existing Pipe , Laying Of One Number Pvc Insulated Power Cable In Existing Masonry Duct , Laying Of One Number Pvc Insulated Power Cable On Surface Of Wall , Supply, Fabrication And Erection Of Ms Cable Tray , Supplying And Laying Of 200 Mm Dia Dwc Hdpe Pipe , Providing And Fixing Earth Bus Of 50 Mm X 5 Mm Copper Strip , Providing And Fixing Braided Copper Of Equivalent Size Of 25Mm X 5Mm Strip , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick , Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface , Supplying And Making End Termination With Brass Compression Gland For 3.5 X 400 Sq. Mm Cable , Supplying And Making End Termination With Brass Compression Gland For 3.5 X 300 Sq. Mm Cable Total Quantity : 3287
Contract Date: Ref. Documents Contract Value : 32.40 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttarakhand View Result →
38.
Power #11287679 Technical Bid
Tender for Procurement Of Mandatory Spares And Essential Parts For 220 Kv & 66 Kv Gis Modules (Make: Jiangsu Jinke, China), Being Proprietary In Nature, Required For Completion Of The Balance Works Of The Under-Construction 220 Kv Gis Substation, Roz-Ka Meo Under Ts Division Palwal (As Risk & Cost Case Pertaining To , Part A- Mandatory Spares Required For O&M- Not Supplied By Previous Contractor M/S Ike Electric Pvt. Ltd , Circuit Breaker (66Kv)Complete Circuit Breaker Pole Of Each Type & Rating Complete With Interrupter, Main Circuit, Enclosure And Marshalling Box With Operating Mechanism.66Kv , Fixed, Moving And Arcing Contacts Including Insulating Nozzles (3 No. Of Each Type) , Rubber Gasket, ‘O Rings And Seals For Sf-6 Gas Of Each Type , Trip Coil Assembly With Resistor As Applicable, 3 Nos. Of Each Type , Closing Coil Assembly With Resistor As Applicable, 3 Nos. Of Each Type , Sf-6 Pressure Gauge Cum Switch Or Density Monitors And Pressure Switch As Applicable, 3 Nos Of Each Type , Coupling Devices For Pressure Gauge Cum Switch / For Connecting Gas Handling Plant, 3 Nos Of Each Type , Relays, Power Contractors, Push Buttons Timers & Mcbs Etc Of Each Type Rating , Auxilliary Switch Assembly, 3 Nos. Of Each Type , Operation Counter, 3Nos Of Each Type , Rupture Disc,3 Nos Of Each Type , Complete Set Of 3 Nos. Of Single Phase/One No. Of 3-Phase Disconnector Including Main Circuit, Enclosure, Driving Mechanism , Copper Contact Fingers For Disconnector Male & Female Contact- For One Complete (3 Phase) Disconnector Of Each Type And Rating. , Interlocking Coil With Resistors, Timers, Key Interlock For Complete 3Phase , Relay,Power Contactors,Resistors,Fuses,Push Buttons & Mcbs A) For Isolator , Aux. Switch Assembly (Complete) With 10 No & 10 Nc Or More Contacts , 72.5 Kv, 2000A,3-Phase High Speed Fault Making Grounding Switch, Internal Parts Complete With All Necessary Gaskets Mounting Hardware Etc. , 72.5 Kv, 2000A,1 Phase High Speed Fault Making Grounding Switch, Operating Mechanism Complete With All Necessary Gaskets Connecting Apparatus , 220 Kv, 2000A,3-Phase High Speed Fault Making Grounding Switch, Internal Parts Complete With All Necessary Gaskets Mounting Hardware Etc. , 220 Kv, 2000A,1 Phase High Speed Fault Making Grounding Switch, Operating Mechanism Complete With All Necessary Gaskets Connecting Apparatus , Current Transformer 220Kv 1Ph Ct Ratio 1200-800-400/1-1-1-1-1 A Complete With All Gaskets And Mounting Hardware , 220Kv 1Ph Ct Ratio 450-300/0.577-1-1-1-1 A Complete With All Gaskets And Mounting Hardware , 66Kv 1Ph Ct Ratio 1500-1000/0.577-1-1-1A Complete With All Gaskets And Mounting Hardware , 66Kv 1Ph Ct Ratio 600-300-150/1-1-1A Complete With All Gaskets And Mounting Hardware , Voltage Transformer/Pt 220Kv220kv ,1-Phase Vt As Per Technical Specifications Complete With All Gaskets And Mounting Hardware , 66Kv ,3-Phase Vt As Per Technical Specifications Complete With All Gaskets And Mounting Hardware , Spare Sf-6 Gas , 66 Kv Bus Insulator (Non Gas Pass) , 66 Kv Bus Insulator (Gas Pass) , 220Kv Insulator Non-Gas Pass , 220Kv Insulator Gas Pass , Tissue Papers (Kimberley Lint Free Wipes) , Spirit For Cleaning , End Plate Of 66Kv Cb Compartment (3Ph) , End Plate Of 220Kv Cb Compartment (1Ph) , End Plate Of 220Kv Ds / Fes / Ct Compartment , Gas-Handling Unit Make Mechfield Sfx-12C T300 , Part B- Essential Parts Required From Commissioning Of 220Kv & 66Kv Gis Make Jiangsu Jinke. , 66Kv Des3 Enclosure With Inner Parts Along With Insulator(5Jd 002 008 Xxdl 201705)-Line 7&8 , 66Kv Bus-2 Ds Enclosure With Inner Parts Along With Insulator(5Jd 002 131 Xxdl 201704)-Line 8 , 220Kv Bus Insulator Non-Gas Pass , 220Kv Cse Female Contacts As Per Pics 220Kv Cse , 220Kv Pt Insulator Gas Pass , 66 Kv Des Enclosure Assembly With Rod Insulator(Part- W/O Mechanism) , Molecular Filter For Sf-6 Gas With Filter Bags Suitable For Des,Ds, Fes And Bus Bar Enclosures For Both 220Kv & 66Kv Gis (Complete Set With 10% Spares)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
39.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
40.
Power #11269168 Price Bid
Tender for Carriage Of Following Material Of Estimate, From Electricity Store Center, Hapur To Site Of Work With Loading, Unloading Multiple Handling, Staking,Labour,T&P And Transpotation At Both Ends On Kachha/Packka Road, As Per Direction Of Site Incharge From Je Store/Store Center Hapur/Ghaziabad/Bulandshar (0-50 Km) Complete In All Respects. , Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit , Cable Box 3X185 O/D Sqmm 11 Kv , 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake , 11 Kv Fuse Set , Plain Cement Concrete Pole 8.5 Mtr Long. , 11 Kv Pin Insulator Polymer , 11 Kv Disc Insulator Polymer , M.S. Channel 100X50x50 Mm , Earthing Complete , 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit , 11 Kv O/D Xipe 3X300 Sqmm C/J Kit , 11 Kv Through 3X185 Sqmm Xlpe C/J Kit , 33 Kv Circuit Breaker 800A, 750 Mva , Acsr Dog. Conductor , Cable Ht Xipe 3X300 Sqmm 33 Kv , Cable Box 3X300 O/D Sqmm 33 Kv , H/S 33 Kv 3X300 Sqmm J/Kit St. Th , Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. , 11 Kv Vcb Incoming , 33 Kv Pt Outdoor (2Set) (2X3=6) , Battery Set 24 Volt , Battery Charger 24 Volt , 33 Kv Ct 400/200/1 annual periodical maintenance , 33 Kv Ct 200/100/1 annual periodical maintenance , 33 Kv Control Pannel Double T/F , 33 Kv Fuse Set , Eraction And Fixing And Making Connection Of Following Material (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. , Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit , Cable Box 3X185 O/D Sqmm 11 Kv , 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake , 11 Kv Fuse Set , Plain Cement Concrete Pole 8.5 Mtr Long. , 11 Kv Pin Insulator Polymer , 11 Kv Disc Insulator Polymer , M.S. Channel 100X50x50 Mm , Earthing Complete , 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit , 33 Kv Circuit Breaker 800A, 750 Mva , Acsr Dog. Conductor , Cable Ht Xipe 3X300 Sqmm 33 Kv , Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. , 11 Kv Vcb Incoming , 33 Kv Pt Outdoor (2Set) (2X3=6) , Battery Set 24 Volt , Battery Charger 24 Volt , 33 Kv Ct 400/200/1 annual periodical maintenance , 33 Kv Ct 200/100/1 annual periodical maintenance , 33 Kv Control Pannel Double T/F , 33 Kv Fuse Set , Providing, Supplying, Laying And Installation Of Hdpe Pipe Of Pe-80 Grade, Pn-6, 200 Mm Diameter By Horizontal Directional Drilling (Hdd) / Trenchless Method For Accommodating 11 Kv, 3×185 Sq.Mm Xlpe Insulated, Armoured Cable, Including Execution Of Road Crossing Or Similar Crossings Wherever Required, Complete With Pilot Drilling, Reaming And Pullback Operations, Proper Jointing Of Hdpe Pipe (Butt Fusion/Electrofusion), All Labour, Tools & Plants, Machinery, Drilling Fluid, Safety Arrangements, Formation Of Entry And Exit Pits And Site Restoration; The Contractor Shall Be Fully Responsible For Obtaining Necessary Permissions, Protection Of Existing Utilities And Resolution Of All Right Of Way (Row/Raw) Issues During Execution. , Laying Of 11 Kv Xlpe Cable Of Size 3X185/3X300 Sq.Mm Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge. , 11 Kv Ht Xlpe Cable 3X185 Sq.Mm With Double Circuit , 11 Kv Ht Xlpe Cable 3X300 Sq.Mm With Double Circuit , Providing The Material And Execution Gi Pipe Earthing With 40 Mm Dia B Class Gi Pipe 80 Feet Boar To Water Level For Proper Earthing ( Earthing Resistance Less Than Or Equal To 1 Omh ) At 33/11 Kv Substation With The Help Of 50Mm X 6Mm Gi Strip Duly Welding To Dt Transformer Other Equipment. With Earthing Mess Lug, Nut And Bolt. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing, Supplying And Fixing Of Copper Bus Bar Of Size 80 Mm × 10 Mm Suitable For 11 Kv Vcb Panel, Including Cutting, Drilling, Bending, Proper Alignment, Insulation Clearance, And Secure Fastening With All Required Nuts, Bolts, Washers And Supports, Ensuring Proper Electrical And Mechanical Connections, Complete In All Respects; The Work Shall Include All Labour, T&P Will Be Provided By Contractor In All Respects. , Grouting Of Following Plain Cement Concrete Pole 8.5 Mtr. Long Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Pg Clamps (Parallel Groove Clamps) Of Suitable Sizes For Making Conductor-To-Conductor Connections, Including Dog Conductor To Dog Conductor And Panther Conductor To Panther Conductor Joints, Complete With All Necessary Nuts, Bolts And Accessories, Ensuring Proper Electrical And Mechanical Continuity, As Per Relevant Standards And Directions Of Site Incharge All Labour, T&P Will Be Provided By Contractor In All Respects. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 11Kv Cable Jointing Kit 3X300 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Providing And Fixing 11 Kv Relay, With (E/F & O/C) Of C&S, Ashide, Abb Make With 1&5 annual periodical maintenance Port Suitable For 11 Kv Feeder Pannel As Per Respo/Norms And As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor With All Labour, T&P In All Respects. , Providing And Fixing Of Wti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti , As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Oti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti, As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Vaccume Interupter In 11 Kv Pannel, As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing 33 Kv Ct Stracture As Per Respo/Norms And As Per Direction Of Site Inchagre Work Includs Grouting Stracture And Making Plinth As Per Norms All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. , Dismantling Of Existing Electrical Equipment At Site, Including Proper Handling To Avoid Damage, And Safe Carriage/Transportation From The Work Site To The Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends, Covering All Leads Over Kachcha And Pucca Roads, Complete With All Labour, Tools & Plants, And Necessary Precautions, As Per The Directions Of The Site Incharge. All Labour Will Be Provided By Contractor In All Respects.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
41.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
42.
Shipping #11247685 Technical Bid
Tender for Summary Sheet Of Bill Of Quantity (Boq) For Operation & Maintenance (O&M) Of 2×15 Mva, 66/11 Kv Gas Insulated Substation (Gis) Along With Associated Switchgear And Auxiliaries At Village Saragwada For National Maritime Heritage Complex, Lothal, Gujarat Schedule Description Of Schedule Rate As Per Estimate Quoted Percentage Above/ Below/ At Per Over Estimate Amount Filled By The Bidder Total Quoted Amount Filled By The Bidder Price In Figure Price In Words % In Figure % In Word Above/Below /At Par In Figure In Word Schedule-A Operation And Maintenance For 1St Year 8070000.0 Rupees Eighty Lakhs Seventy Thousand Only Schedule-B Operation And Maintenance For 2Nd Year 8473500.0 Rupees Eighty-Four Lakhs Seventy-Three Thousand Five Hundred Only Schedule-C Operation And Maintenance For 3Rd Year 8897175.0 Rupees Eighty-Eight Lakhs Ninety-Seven Thousand One Hundred Seventy-Five Only Total Estimated Amount In Figure Rs 2,54,40,675.00/- In Words Rupees Two Crores Fifty-Four Lakhs Forty Thousand Six Hundred Seventy-Five Only Total Quoted Amount By The Bidder In Figure In Words Name Of Bidder : Bill Of Quantity(Boq) Estimate For Operation & Maintenance (O&M) Of 2×15 Mva, 66/11 Kv Gas Insulated Substation (Gis) Along With Associated Switchgear And Auxiliaries At Village Saragwada For National Maritime Heritage Complex, Lothal, Gujarat Schedule-A: Operation And Maintenance For 1St Year Item No. Description Of Work Unit Boq Qty. Rate Excl. Gst (In Rs) Amount Excl. Gst (In Rs) , Operation & Maintenance Of 66/11 Kv Substation, 2 X66 Kv Meterig Feeder Bay, 2 X66 Kv Gis Line Bay, 2 X66 Kv Gis Tr. Bay And Other Equipment In Gis Building , Annual Testing Of Equipments Total Amount Of Schedule A For 1St Year Excluding Gst (In Rs) 8070000.0 Bill Of Quantity(Boq) Estimate For Operation & Maintenance (O&M) Of 2×15 Mva, 66/11 Kv Gas Insulated Substation (Gis) Along With Associated Switchgear And Auxiliaries At Village Saragwada For National Maritime Heritage Complex, Lothal, Gujarat Schedule-B: Operation And Maintenance For 2Nd Year Item No. Description Of Work Unit Boq Qty. Rate Excl. Gst (In Rs) Amount Excl. Gst (In Rs) , Operation & Maintenance Of 66/11 Kv Substation. 2 X66 Kv Meterig Feeder Bay, 2 X66 Kv Gis Line Bay, 2 X66 Kv Gis Tr. Bay And Other Equipment In Gis Building , Annual Testing Of Equipments Total Amount Of Schedule B For 2Nd Year Excluding Gst (In Rs) 8473500.0 Bill Of Quantity(Boq) Estimate For Operation & Maintenance (O&M) Of 2×15 Mva, 66/11 Kv Gas Insulated Substation (Gis) Along With Associated Switchgear And Auxiliaries At Village Saragwada For National Maritime Heritage Complex, Lothal, Gujarat Schedule-C: Operation And Maintenance For 3Rd Year Item No. Description Of Work Unit Boq Qty. Rate Excl. Gst (In Rs) Amount Excl. Gst (In Rs) , Operation & Maintenance Of 66/11 Kv Substation. 2 X66 Kv Meterig Feeder Bay, 2 X66 Kv Gis Line Bay, 2 X66 Kv Gis Tr. Bay And Other Equipment In Gis Building , Annual Testing Of Equipments Total Amount Of Schedule-C For 3Rd Year Excluding Gst (In Rs) 8897175.0
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
43.
Power #11237858 AOC
Bids Are Invited For Interconnecting 400/220 Kv Gis Jalpura (Tbcb Project) With Upptcl Substations By Revamping 02 No. 220 Kv Bays At 220/132 Kv Gis Jalpura Under Etd-Ii, Noida; 1.0 Erection of Main & Auxiliary structure Lattice type DTM,ETM,BXM,ALP,BCT etc. consisting of column, beam, peak etc and auxiliary structure for installation of LAs, CVTs etc. The job consist of shifting of all materials from store to site of erection, erection of structure as per drawing with the help of GI nut & bolt, spring washer, matching the hole, cutting & matching of member if required including cost of all men and T&P excluding GI structure, nut & bolt to complete the work. Erection of Main & auxiliary structure lattice type BCT, ALP etc. upon foundation and its proper tightening. 2 Erection of following equipment as per technical specification, manual and instruction as per direction of supervising engineer. a 220 kV Lightning Arrester b 220 kV Capacitor Voltage Transformer with junction box. 3.0 Dismantling of all 3 phases of existing HTLS Hamburg conductor, all hardware fittings & conductor accessories e.g. armour rod, vibration dampers, insulator strings etc. from tower location no. AP-74 (third tower from gantry) to AP-75 to AP-76 tower to 220 kV gantry having approx. 800 mtr in length including dehoisting of insulators as all towers and gantry and de-jumpering from cable sealing termination to CVT to LA and shifting of materials to store as per instruction of supervising engineer. 4.0 Laying, tensioning, stringing, clamping, jointing etc. complete with HTLs Hamburg conductor from tower location no. AP-75 (second tower from gantry) to 220 kV extended gantry having approx. length 250 mtr including hoisting of insulator at gantry and AP-75 tower end for all three phases, fitting of all necessary hardware and accessories i.e. armour rods, vibration dampers etc. along with droper and jumpering for interconnction of equipment with the conductor from LA to CVT including cutting of conductor, bending in proper shape and all associated works viz cutting & bending of conductor and all other necessary associated work as per direction of supervising engineer. 5.0 Jumpering, interconnection of equipment with the conductor from cable sealing termination to CVT to LA including cutting of conductor, bending in proper shape, clamping with the help of clamps and all other associated work to complete the work satisfactorily. 6.0 Laying & stringing of earth wire including fixing of all kind of hardwares as per instruction of supervising engineer.
Contract Date: Ref. Documents Contract Value : 1.57 Lakh
Government Departments No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Jun 15, 2026 Contract Value : 7.48 Lakh
Government Departments No of Bidders 3
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.09 Crore
Government Departments No of Bidders 1
Uttar Pradesh View Result →
46.
Power #11206303 Price Bid
Tender for Contract For Supply Of Key Materials Required For Maintenance Of 33/11Kv Receiving Stations Along With Their Lines Under The Jurisdiction Of Std Bijbehara During The Year 2026-27 , Electrical Store/Workshop Items/: As Per Is Standards , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Incommer) As Per Technical Specifications Of Rec Std , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Outgoing) As Per Technical Specifications Of Rec Std , 33 Kv Vcb (36 Kv, 1250A, 26.2 Ka, Outdoor Type) As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Out Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv Isolator With Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Isolator Without Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Outdoor, Oil Cooled, Live Tank, Single Phase , 3 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection,0.5 For Metering & Ps For Differential With Ratio 800-400/5-5-5A ,600-300/5-5-5A , 500-250/5-5-5A, 400-200/5-5-5A (Per Set Of 3 Pieces) , 33 Kv Outdoor, Oil Cooled, Copper Wound , Single Phase , Pt Set With Rated Primary Voltage 33000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 (Per Set Of 3 Pieces). , 33 Kv Lightening Arrestors (30 Kv, 10Ka, Station Class, Zno, Porcelain/Polymer) Gap Less(Per Set Of 3 Pieces). , 33 Kv Post Insulator (Polymer/Porcelain 36Kv, 170Kv Impulse) , Galvanised Steel Structures(6 G I Pipe With Top,Base & Grouting Bolts) As Per Rec , 11Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 2.5 Sqmm 2 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 4 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 6 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 8 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , L T Cable 3 1/2 16 Sq.Mm Core Armored , Al Conductor Sheathed Pvc Insulated (Std Make) , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Or Raychem Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 120Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 120Qmm , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 11 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb, Electric Field, Sudhir Or The Like , 11 Kv Indoor Type,Dry,Resin Cast, Single Phase , 2 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection & 0.5 For Metering Preferably Of Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make Having) With Ratio 800-400/5/5,600-300/5-5,400-200/5-5 (Per Set Of 3 Pieces). , 11 Kv Indoor ,Dry, Copper Wound , Three Phase , Pt Set In Ms Enclosure With Rated Primary Voltage 11000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 , 11 Kv Lightening Arrestor Set( Station Type),Outdoor, Metal Oxide Gapless As Per Isi Specifications.(Per Set Of 3 Pieces). , Digital Protection Relay Non-Communicable Model Type 141A (Ashida/Er Make) 3 O/C +1 E/F For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make . Auxillary Voltage 30V Ac/Dc Confirming To Iso 9001:2008 Standards. , Master Trip Relay 24-50V For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make. , 36V , 200Ah Battery Bank (Comprising Of 3 No Batteries Of 12 V Each) Conforming To Iec60896-21/22, Lead Acid Type Of Exide Make , 36 V,200 Ah , Float-Cum-Boost Battery Charger,Copper Wound,Air Cooled, With Full Wave Rectification With Heat Sink & 40A Diodes, Ae Make Measuring Instruments, 16Swg Steel Body Sheet, For 15A,220 V, 1Phase, 50 Hz Ac Input Supply Along With Ac/Dc Terminal & Earthing Slot, Correction Time 10Sec, Std Make , 5Kva Servo Motor Control Voltage Stablizer With Input 100V & Output 220V,Air Cooled,50 Hz,16Swg Steel Body, Copper Wound , Correction Time 10 Sec, Std Make , Auxillary Switch Suitable For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Panel Bush For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Bush(Bus Bar Spout) For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Interruptor Housing For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Limit Switch For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Contact/Female Contact For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make , 36V Tripping Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field, Sudhir Or The Like , 36V Closing Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Sudhir Or The Like , Digital Ammeter/Voltmeter (Programmable)For 11Kv Vcb Panels , Panel Indicators , Ammeter Selector Switch Of 11Kv Vcb , Tnc Switch Of 11Kv Vcb , Spring Charging Motor Of 11Kv Vcb Breaker , Spring Charging Motor Of 33Kv Vcb Breaker , Gears For 11Kv Vcb Of Different Make(Big) , Gears For 11Kv Vcb Of Different Make(Small) , Dc Delco Motor For 33 Kv Vcb , Dc Delco Motor For 11 Kv Vcb , Transormer Oil As Per Is For Power Transformers,Cts,Pts Etc , Distilled Water For Battery Bank , Almunium Alloy Clamps Of Sizes Like Ct,Pt,Pad,Isolator,La,T Etc For 100/200Mmsq Acsr , 33 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250 Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb,Megawin,Sudhir Or The Like , 33K Vcb Bushe Complete Assembly Confirming To Is:2099 Standard , 33Kv /11 Kv Bushes Of Power Transformers Complete Assembly Confirming To Is:2099 Standards , 11Kv/ Lv Bushes Along With Bush Rods Of Auxillary Transformers Complete Confirming To Is: 2099 Standards , 33Kv P.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bush Rod , 33Kv Isolator Grovees(Knife/Tubular Type) Complete , Almunium Tubular Bus Bar As Per Rec , 11Kv G.O Set 400 Amps , 11Kv Isolator, Double Break,3-Pole, 600Amp, Horizental Mounting Type, With Earth Switch. , 11Kv Link Set,Copper Knife(50X6x450)Mm,400 Ampers, Complete With Clamps , 33Kv Link Set,Copper Knife (50X8x600)Mm,800 Ampers, Complete With Clamps Heavy Duty , 33Kv Do / Fuse Set , Distribution Panel (30V, Dc) With 1 No.10Amp. Mccb. Double Pole For Battery Incoming Supply With Dp Mcbs & Indicating Lamps Etc. , Distribution Panel (415 V, Ac) Complete With Ckt. Breakers, Indicating Lamps Etc. , Led Lamps Of Control Room Building ( 9-15 Watts) , Led Lights For Yard( 50 Watts) , Almunium Paint , Red Oxide Paint , Almunium Thimbles Of Sizes(120-600 Sqmm) , 11 Mtr Long S.T Poles (410Sp- 56) Complete With Base And Cap As Per Rec Standard And Specifications , 9 Mtr Long S.T Poles (410Sp- 33) Complete With Base And Cap As Per Rec Standard And Specifications , 13 Mtr Long S.T Poles (410Sp- 69) Complete With Base And Cap As Per Rec Standard And Specifications , 0.2 Acsr (Panther) Conductor , 0.15 Acsr (Wolf) Conductor , 0.1 Acsr (Dog) Conductor , 0.05 Acsr (Rabbit) Conductor , Fabricated Galvanised V -Type Channel Iron X-Arm,6-10 Long Ch Iron,Channel Iron Top,Angle Iron Belts, Clamps & Flat Braces Etc As Per Rec Standard For 33/11Kv Lines. , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm , 33 Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Suitable For 0.1 Acsr Conductor , P G Clamps For 200/150/100Mm Sq Acsr , 33 Kv Danger Plates With Clamps , Anticlimbing Devices With Clamps , Gal Nuts & Bolts With Washers , Earthing Complete By G I Pipe 40Mm Or G I Rod 20Mm 2.5 Mtr Long Through G I Strip As Per Rec Standard , Galvanised Stay Set With 50X8mm Stay Clamps,Guy Insulator,Anchor Plat(300X300x8)Mm,Nuts/Bolts ,Turn Buckle,1.8 Mt Long 20Mm Dia Sold Gs Stay Rod & 7/4.0Mm Dia Gi Std Wire Complete , Guard Netting As Per Rec Standard , Galvanised Spiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard , Porceline 70 Kn Disc Insulator , Porceline 45 Kn Disc Insulator , Porceline 33Kv Insulators (10 Kn) , 33Kv G.I Pins With All Accessories Weighing 2700 Gms , 33Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , 11Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , Electrical Insulating Rubber Mat 6Mm Thickness(1Mrx2mtr). , 63 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , 100 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , Digital Three Phase Voltmeter , Porceline 11Kv Insulators , 11 Kv G.I Pins With All Accessories , Coper Bus Bar , Drill Bilts Of Sizes 3/4 And 1 , Hexa Blade , Round Hexa Blade , Welding Rods , Bush Rods For 10Mva, 6.3 Mva , Monoplastic Tape Rolls , 11Kv Pannel Hrc Fuses , Ac/Dc Mccb Of Different Ratings , Oil Temperature Indicator Of Reputed Make For 33/11-6.6Kv Power Transformers , Winding Temperature Indicator Of Reputed Makefor 33/11-6.6Kv Power Transformers , Standard Quality Silica Gel For Various Capacity 33/11Kv Power Transformers , Breaker Mechanism Of Reputed Make , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Sauitable For 0.15/0.2Acsr , 2.5 Sqmm 12 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 33Kv Grade, 1 Core Heat Shrinkable Jointing Kit, Including Required Size Of Lugs/Thimbles, As Per Relevent Is Specification 7098 (Part-Ii) 3M/ Raychem Suitable For 630/400/300Sqmm , Buchholz Relay For 33/11-6.6Kv Transformer Protection , Twin Bimettalic Clamps Aaac Equivalent 8 Bolt Type With Four Outputs As Per Relevant Is Standard Suitable For 01/0.2Acsr , Ht Tape Roll As Per Is Standard With Latest Ammendments , Indication Lamps Suitable For 33/11Kv Panel Board Ike Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir / Pascal/Hartek Make , Monoplast Tape As Per Is Standard With Latest Ammendments , Lt Insulation Tape As Per Is Standard With Latest Ammendments , Old Sarees , Earthing Electrodes As Per Is Standard With Latest Ammendments , 11Kv Auxillary Relays. , Al Alloy Tension Fittings Suitable For 50/100/150/200 Sqmm Acsr As Per Rec , Almunium Folded Ladder , Bus Bar Type Clamp For Connecting Ic Cable Outdoor , Water/Snow Resistant Shoes (Tsf Make Or Any Equivalent Brand) , Rain Coat Long Size Over Coat Type (Size 4Xl) , Umberlla Big Size , Safety/ Industrial Helmet With Straps Isi Mark, With Head Lamp Bracket And Detachable And Interchangeable Led Headlamp Alongwith Charger/Charging Facility(Color:- White , Blue And Yellow ) , Chainsaw Cutter Heavy Duty 1800-2500 W , Chainsaw Cutter Heavy Duty (Portable) 1000-1500W , Searchlight Heavyduty (Eveready, Panasonic/Philips Or Equivalent) , Heat/Flame Gun Metallic For Cable Kit Shrinking With Portable Butane Gas Can 225G Of 01No. , Butane Gas Cartridges/Canisters, Refill Fuel For Welding Torch, 225G , Electric Heat Gun For Cable Kit Shrinking 1000-200 Watt , Heavy Duty Tool Kit (Flat/Round Spanner Set, Plier, Screw Driver Set, Wire/Cutter/Striper, File With Torque Spanners Set Etc Complete Set) , Al. Ladder Foldable 2X20 Ft. Telescopic Portable Ladder , Digital Megger 5 Kv , Digital Megger 2.5 Kv , Cork Sheet 4Mm , 2V Battery 100Ah Vrla Type Of Standard Make , 2V Battery 200Ah Vrla Type Of Standard Make , 12V Battery 200Ah Lead Acid Type Of Standard Make , 33 Kv Current Transformer Outgoing/Incomer (33 Kv, 1Φ, Multi Ratio Multi Core 600-300/1A, Indoor Type) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted At Pahalgam , 11 Kv Current Transformer Outgoing (11 Kv, 1Φ, Multi Ratio Multi Core 200-400/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted (Pahalgam) , 11 Kv Current Transformer Incommer (11 Kv, 1Φ, Multi Ratio Multi Core 900-600/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station (Pahalgam) , 33 Kv Single Core Indoor Cable Kit ( Plug In Tremination Type And Screened Seperable Connectors ) For 400 Mmsq Cable For Gis Compatible Substaion (Brand:- Euromold, Nexans, Raychem Etc) , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 33Kv 1Corex400nmsq,Nndia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 11Kv 1Corex 400Mmsq,Ins Dia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Inner Core Plug In Termination Kit To Suit Size-3-Lcx630mmsq 12/20(24Kv) installation Dia: 34.0-45.06 Complete Set With All Accessories Per Set Of 3Nos Of Standard Make Gis Compatible Substation , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,630 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 11Kv 3 Core Cable Jointing Kit Of Sizes 185/240/300/400 Sqmm , 11Kv 1 Core Cable Jointing Kit Of Sizes 185/240/300/400/630 Sqmm , ⁠630 Mmsq Hydrolyic Crimping Tool , ⁠Electric Grinder 700 To 1000 W Of Standard Make , Electric Digital Welding Machines (Portable Of 100 - 250 Amps , 11Kv Cable Jointing Kit , Oil Pump Manual Of Standard Make For Transformers , Foam Spray Sealant Tins Of 450Ml , Vaseline/Grease , 11Kv Cts Of Different Ratios And Make Like Electricfield, Pasxcal, Sudhir, Stelmac Etc.) , T Clamps For Acsr 200Mmsq , Retaining Pins, Lock Nuts Of Sizes, External Retaining Rings(Rotor Clips, E Clips, C Clipso/S, Split Pins/Cotter Pins O/S , Single Phase 1 Hp Water Motor Of Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
49.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 3.97 Crore
Boards / Undertakings / PSU No of Bidders 1
TenderDetail
Loading tenders