View Bid Results For Gis Application Tenders

We found 1988 Bid Results related to gis application tenders. You can find Contractor details who won gis application tenders along with contract details in Bid awards announcements section.

Filters
Stage
1536
273
179
Tender Publishing Platform
230
1758
State / UT
36
290
249
181
145
119
106
105
98
95
92
67
50
48
44
42
33
27
24
22
21
19
17
14
12
11
10
9
9
7
5
5
5
2
2
2
1
Contract Value
580
295
818
292
Publish Date
7
0
0
0
0
Sector
29
724
268
267
135
87
78
57
50
46
42
37
29
25
23
17
16
14
10
10
8
8
7
7
5
5
5
3
3
2
Ownership
7
788
770
242
177
6
4
1
Within keyword
Active filters:
Showing 1–40 of 1988 tenders matching your filters
1.
Defence #11483749 AOC
Tender For Supply Of Bhavan Item And Jal Samagri At Nscb Central Jail Jabalpur (M.P.) - Aggregate (all sizes)2. Cement3. Sand (coarse) (fine)4. M Sand5. P Sand6. Dust/Gira Aggregate7. Iron Rebars (6mm, 12mm, 18mm)8. Iron Pipe (20 feet) (various sizes)9. Iron Strip (all sizes)10. Profile Sheet (0.45mm) (all sizes)11. Transparent Sheet (with mesh) (all sizes)12. Transparent Sheet (without mesh) (all sizes)13. Steel Khila (all sizes)14. GI Sheet (0.3 feet wide)15. Painted GI Sheet Plain seat 03 feet wide16 Binding wire for centering17 Centering with installation18 Iron angles (all sizes)19 Tiles20 UPVC pipe 0.521 UPVC pipe 122 UPVC VC Pipe 1.2523 UPVC Pipe 1.524 PVC Pipe 0.525 CPVC Pipe 0.526 PVC Pipe 127 PVC Pipe 628 PVC Pipe 429 Plastic Faucet30 Kota Stone31 Rubber Pipe 1 (Shut) (50 ft bundle)32 Brass Valve 133 Brass Valve 1.534 Brass Valve 235 Brass Gate Valve 436 Gate Valve (Iron Frame, Valve & Key in Brass) 437 Gate Valve (Iron Frame, Valve & Key in Brass) 238 Gate Valve (Iron Frame, Valve 1.539 Gate Valve (iron frame, valve and key in brass) 140 Indian Seat with Cock41 Western Seat with Cock and Cover42 Asphalt Washer43 J Hook (with nut and washer)44 Nut bolts in all sizes45 Urine Pot46 White Putty47 White Putty (Waterproof)48 Welding Rod (for iron)49 Welding Rod (for steel)50 Plastic Water Tank 3 Layer ISI Mark (Rate per liter)51 Machine Screw 1 inch52 Machine Screw 1.5 inch53 Machine Screw 2 inch54 Machine Screw 2.5 inch55 Fall Ceiling per square foot56 Iron Mesh Square (all sizes)57 Steel Mosquito Net58 Steel Cock Mesh59 Emulsion60 Distemper61 PVC Bathroom Door with Frame Set (Full Size with 1-inch Board)62 PVC Door Board 1-inch63 PVC Door Frame Running Fit64 Ply Wood Doors Full Size (35 mm Thick)65 Steel Aldrop Set 6-inch66 Steel Aldrop Set 8-inch67 Paver Blocks All Sizes Thickness 80mm68 Paver Blocks All Sizes Thickness 60mm69 Tarfelt Installation (per square meter)70 Tarfelt (Bituminous 20m x 1m x 1mm)71 Tarfelt (Bituminous 20m x 1m x 2mm)72 Tarfelt (bitumen 20m x 1m x 3mm)73 Tarfelt application primer (20 liters per pack)74 Safety belt (for construction work)75 Helmet (for construction work)76 HDPE pipe 1 inch77 HDPE pipe 2 inch78 GI JP jointer 1 inch79 GI JP jointer 2 inch80 GI JP jointer 3 inch81 GI socket 1 inch82 GI socket 1/2 inch83 GI elbow 1 inch84 GI elbow 1/2 inch85 Teflon tape86 UPVC solvent87 PVC solvent88 CPVC solvent89 UPVC socket 1 inch90 UPVC Elbow 1 inch91 UPVC Brass Elbow 1 inch92 UPVC Gatewall 1 inch93 UPVC Tee 1 inch94 UPVC Socket 1/2 inch95 UPVC Elbow 1/2 inch96 UPVC Brass Elbow 1/2 inch97 UPVC Gatewall 1/2 inch98 UPVC Tee 1/2 inch99 UPVC FTMT 1/2 inch100 Emulsion/Oil Paint Painting Labor Charge101 Distemper Painting Labor Charge102 Lime Painting Labor Charge103 Iron Cutter Blade 4 inch104 Tile Cutter Blade 4 inch105 Waterproofing (for ceilings and walls)106 Aluminum Work with Material and with Installation Complete Work (doors, windows, and partitions)107 GI hinges 3”108 GI hinges 5”
Contract Date: Jul 02, 2026 Contract Value : 40.03 Lakh
Government Departments No of Bidders 4
Madhya Pradesh View Result →
2.
Rural Development #11481883 AOC
Tender For Annual Plan-Kuzhimanna Grama Panchayat Installation Of Mini Mast Lights-So315/26-General Electrical Work - wiring 2 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters 3 90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 4 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 5 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). 6 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels 7 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm 8 OD257774/2025-2026:SupplyandfixingoffollowingsizesofCorrugated PVC flexible conduit alongwithaccessoriesin surface/recess of proposed pole andmakinggoodthesameincaseofrecessed conduit as required 25 mm Corrugated PVC flexible conduit 9 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm 10 OD257790/2025-2026:Supply,installation,testing and commissioning ofDigital time swtch 40A, 2pole , AC1 rated power contactor with 1NO+1NC auxiliary contacts with AC coil and 24 Hours timer for operating automatic ON-OFF function suitable for single phase supply 11 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 12 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 13 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 14 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 15 OD257771/2025-2026:Supply and Fixing of 1P+N,40KA,1 module surge protector on existing MCB DB/enclosure/Meter Board etc and giving connection as required. (Schneider A9L40500 or equivalent) 16 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 17 OD257773/2025-2026:5 mm X 3 mm G.I. strip earth lead Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate 18 OD257775/2025-2026:Supply and installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-5345-NF ] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required 19 OD257780/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc 20 OD257777/2025-2026:Supplying and fixing32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board 21 OD257781/2025-2026:Supplying and fixing32A, HRC Fuse with HRC Fuse link with connections, in existing meter board 22 OD257778/2025-2026:Supplying and fixing of following sizes oflight class PVC conduit along with accessories in surface/ recess including cutting the wall/ground and making good the same in case of recessed conduit as required as service pipe 23 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board 24 OD257875/2025-2026:Supply, Providing and fixing Granite of any colour and shade for Name board, of required size laid over base of cement mortar 1:4 (1 Cement : 4 Coarse sand), including all charges etc. complete all, levels, including lettering and fixingetc as required at site. 25 OD257779/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required
Contract Date: Jul 01, 2026 Contract Value : 1.14 Lakh
Local Bodies No of Bidders 2
3.
Defence #11465339 Price Bid
Tender for Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Not Exc 1.50 Sqm Each And Removing From Site Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Exc 1.50 Sqm Eachand N Exc 4 Sqm And Removing From Site Complete All As Specified And Directed.. , Demolition Of Brick Work Built In Cement Mortar Including All Quions, Arches, Pillars Etc But Excluding Ashlar Facings Dressed Stone Work And Precast Concrete Articles Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Complete All As Specified And Ditrected. , Dismantling Of Stone Slabs And Tiles Laid Bedded And Pointed In Any Mortar Of Any Description Or Thickness In Floors, Aprons Etc. Complete All As Specified And Directed. , Demolition Of Cement Concrete (Reinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Reinforcement Cut As Required To Facilitate Demoltion Complete All As Specified And Directed. , Taking Down Cement Plaster On Brick Or Stone Wall Etc Including Racking Out Joints, Hacking For Key Scrubbing Down With Water Etc To Receive New Plaster Etc.Complete All As Specified And Directed. , S&F Pressed Steel Frames Of Size 125 Mm X 60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc. Complete All As Specified And Directed. , S&F Pressed Steel Frames Of Size 105 Mm X 60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc Complete All As Specified And Directed. , S & F For 35 Mm Thick Factory Made, 2Nd Class Hard Wood Glazed And Skeleton Shutters Open Rebeated And Prepared To Received Glass, Gauzed, With Out Sash Bar Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitered Beads For Securing Glass Etc, Size Of Member Of Shutter As Per Specified In Ssr Part-I Section 8, Clause 8.24 (A) And For Door And Fixed With Chowkats, Chemically Pressure Treated Complete All As Specified And As Directed. , S&F For 35Mm Thick 2Nd Class Hard Wood Plain, Framed Pannelled Shutters (Two Panel) With Lock Rail And Panel Of 9Mm Bwp Commercial Ply Or 12Mm Veneered Particle Board Wiyh Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per (Is : 1003 Part-I , Kiln Seasoned And Chemically Pressure Treated Complete All As Specified And As Directed. , S&F Powder Coated Aluminium Frame Work (Min Thickness Of Powder Coating 50 Micron) For Doors, Windows, Ventiltors And Partition, (Sliding/Openable/Fix Doors, Windows, Ventilator), Etc With One, Two Or More Rebates (Reqd As Per Site), Section Weighing Not Less Than 0.55 Kg/M, Including Joining Cleat For Fixing With Dash Fasteners Of Required Dia And Size, Incl Filling Up Gaps At Junctions, Ie Top, Bottoms And Sides Etc Complete All As Sspecified And Directed.. , S&Fpowder Coated Aluminium Window And Ventilator Shutters, Sliding/Openable/Fixed (As Per Required At Site) Type Without Sash Bar, Alu Section Weighing 0.55 Kg/M, Including Necessary Locking Arrangement, Guide Wheels, Joining Cleats, Glazing Clips Rubber Packing Anodised Alu Snap Beading Screws Etc Complete All As Specified And Directed. , S&F For Sheet Glass Palin/Coloured (As Per Directed By Engr-In-Charge) 3Mm / 5 Mm Thick Best Quality And Glazing With Rubber Packing, Screws Or Glass Putty In Squares Exc 0.5 Sqm Each Pane Complete All As Specified And Directed. , S & F For Stainless Steel Wire Cloth Of 0.36Mm Dia Wire And Average Width Of Aperture 1.40Mm & Fixed With Tacks Or Screws, Wire Staples, Etc Complete All As Specified And Directed. , S&F Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With Ms Square Tube With Wooden Grain Printed Pvc Sheet Used Inserted Of Plain Colour Pvc Sheet & Edges Will Be Painted To Match With Printed Sheet Complete All As Specified And Directed. , S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of Ms Tubes For Top & Bottom Rails. Ms Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C Channel Having A Pvc Sheet Strip Of 20 Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail. Panelling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded/Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Complete All As Specified And Directed. , S&F 100 Mm Long Mild Steel Butt Hinges, Cold Rolled, Medium Weight Complete All As Specified And Directed. , S&F For 125Mm Long Anodised Aluminium Barrel Tower Bolt Of Extruded Section Complete All As Specified And Directed. , S&F 150Mm Long Anodised Aluminium Handles, Cast Type Complete All As Specified And Directed. , S&F300mm Long Aluminium Alloy, Anodized Sliding Door Bolt With Hasp Stapple ( Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy And Fixed Complete All As Specified And Directed. , S&F For 20 To 25 Mm Dia Stainless Steel Drapery Curtain Rod With Brass /Nickel Chrom Polish / Designer Lattos And Brackets Complete All As Specified And Approved By Engr-In-Charge Including Taking Out Old Pelmet With Curtain Rods Complete All As Specified And Directed. , S&F 300 Mm Long Mild Steel Ordinary Rat Tail Rod Pattern Spring Including Roller And Roller Plate Complete All As Specified And Directed. , S& F Floor Door Stopper Of Aluminium Alloy Body And Tongue ,Anodised ,With Hard Drawn Steel Spring ,Fixed In Floor Overall Length Of Cover Plate 140Mm Complete All As Specified And Directed. , S & F For Pvc And Cupboard Shelf/ Partition/ Frame / Shutter Of 18Mm Thick Side Of Panel Externally Impact Perfact Finish To The Shutter And Joined Together With Solvent Cement Adhesive 8Mm Thick (4Mmx2)X12mm Wide Pvc Sheet Is Used As Gap Insert For Top & Bottom Rail, 18Mm X 1Mm Pvc Edge Lipping Is Done On Top & Bottom Side Using Pvc Solvent Cement Adhesive, Incl Hasp And Stable For Locking Purpose, Etc Complete As Per Direction Of Engr-In-Charge, Manufactures Specification And Drawing Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Straight Or Curved On Plan Exc. 6M Mean Radius Built In Cement Mortor 1:6., Etc Complete All As Specified And Directed. , M & L For Brick Work With Sub Class B Modular Bricks, Straight Or Curved On Plan To Any Radius Built In Cm 1:4 In Half Brick Thick Walls Complete All As Specified And Directed. , M&L For Rendering 10Mm Thick In Cm 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , M&L For Rendering 15Mm Thick In Cm 1:4 On Other Than Fair Faces Of Brick Or Concrete Surface With Liquid Water Proofing Compound @ 200 Ml Per Bag Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed.(Note:- Liquid Water Proofing Compound To Be Measured Paid Separately) , M&L For Rendering 5Mm Thick In Ceiling Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , Supply Only Integral Water Proofing Compound Complete All As Specified And Directed. , M & L For Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. , M&L Plain Cement Concrete 1:4:8, Type D2( Using 40Mm Graded Stone Aggregate) 75Mm Thick As In Sub Base Of Floor Complete All As Specified And Directed . , M & L 25Mm Thick Cement Concrete Type B-0, 1:2:4 (Using 12.5 Mm Graded Aggregate) For Levelling Course In Floors Complete All As Specified And Directed. , M&L For Scratch Free Vitrified Light Shade Floor Tiles 10Mm Thick (Square Or Rectangular) Area Of Each Tile Not Exceeding 0.36 Sqm ,In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface With And Including 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directed. , All As Per Item No 35 Above But As In Skirting/ Dado Etc With And Including 10Mm Thik Backing Coat In Cement Mortar 1:4 An Wall Complete All As Specified And Directed. , M & L For Non Skid Joint Free Coloured Ceramic Floor Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exc 0.11 Sqm But N Exc 0.18 Sqm,In Floor Etc Set & Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface With 15Mm Thick Screed Bed Or Bedding Layer In Cm (1:6) Complete All As Specified And Directed. , M&L For Glazed Ceramic Coloured Wall Tiles (Textured And Design As Required) In Vertical Surface 450X300x7mm Thick, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10 Mm Thick Rendering In 1:4 Cm Complete All As Specified And Directed. , M & L For Applying Two Coat Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. , M & L For Preparing New Plastered Surfaces Of Wall And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Cement Primer And Over A Coat Of 2 To 3Mm Thick Wall Care Putty Complete All As Specified And Directed. , M & L For Preparation Of Newly Plastered Surfaces Of Walls And Applying Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gms/Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per Manufacturers Specification. Two Or More Coats On New Work Over A Coat Of Wall Care Putty 3Mm Thick Complete All As Specified And Directed. , Material And Labour For Apply Two Coats Of Anti Fungal Weather Coat Acrylic Emulsion Paint Over A Coat Of Primer On New Surfaces Including 2 -3 Mm Thick Wall Putty, Complete All As Specified And Directed. Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Claim On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , M & L For Preparing New Plastered Surface On Ceiling And Applying Three Coat Of White Wash Complete All As Specified And Directed. , M&L For Preparation Of Old Decorated Plastered Or Unplastered Surface Including Complete Removal By Brooming Down With Steel Wire Brushing, Scraping Down Smoke Soot, Moulded, Moss, Efflorscent Salt, Trading Oil And Greasy Spots And Applying Two Coat Of Oil Bound Distemper On Walls Over 2Mm Thick Plaster Of Paris Putty As Specified And Directed By Engr-In-Charge. , M&L For Preparation Of Old Decorated Plastered Or Unplastered Surface Including Complete Removal By Brooming Down With Steel Wire Brushing, Scraping Down Smoke Soot, Moulded, Moss, Efflorscent Salt, Trading Oil And Greasy Spots And Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) On Walls Over 2Mm Thick Plaster Of Paris Putty As Specified And Directed By Engr-In-Charge. Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Claim On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , M&L For Three Coat Of White Wash On Old Surface On Ceiling Including Preparation Of Surface Complete All As Specified And Directed. , M & L For Machine Cut Kota Stone Slab Flooring 20 To 25Mm Thick (Size Not Less Than 550Mm X 550Mm) Laid & Jointed With Grey Cement Mixed With Pigment To Match The Shade Of Slab Including Rubbing And Mirror Polishing Finished Laid Over And Including 20Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And As Directed. , M & L For Machine Cut Kota Stone Slab Flooring 18 To 20Mm Thick As In Riser Of Step, Dado And Skirting Over And Including 10Mm Thick 1:4 Cm Backing Coat On Vertical Surface Of Wall With Rubbing And Mirror Polishing Finished Complete All As Specified And As Directed. , M&L Plain Cement Concrete 1:3:6, Type B1( Using 20Mm Graded Stone Aggregate) 75Mm Thick As In Plinth Protection Complete All As Specified And Directed . , Demolition Of Cement Or Lime Concret In Any Despription Along With Tarfelt Treatment In Sunken Portion / Roof And Cement Mortar Bedding From Roof Removal Rubbish Out Side Md Land Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:2:4 Type B-0 Using 12.5Mm Graded Crushed Stone Aggregate As In Sunken Portion, Subbase, Etc Complete All As Specified And As Directed. , M&L For Rendering 10Mm Thick In Cm 1:4 On Roof Suraces With Liquid Water Proofing Compound @ 200 Ml Per Bag Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , M&L For Water Proofing Treatment To Sunken Portition / Roof Etc. In Following Sequence:- (I) Properly Cleaning And Drying The Surface (Ii) Applying A Coat Of Bitumen Primer @ 1.2Kg/Sqm And Primer Shall Be Allowed To Dry Over Night. (Iii) Laying App Based Modified Water Proofing Membrane Of Weight Not Less Than 3Kg Per Sqm And Thickness Not Less Than 3 Mm, With 100Mm Overlaps, Sealed And Bonded To The Surface By Torchon Method (Iv) Applying Two Coat Of Bituminous Based Aluminum Painting @ 0.15 Kg/Sqm Each Coat On Water Proofing Treatment With Preparation Of Surfaces Complete All As Specified And Directed. , S&F Vitreous China Wash Down Water Closet Pan Semi Pedestal Pattern(Anglo Indian Type), White (Excluding Fixing Bolts, Flushing Cistern And Flush Pipe(Excluding Flushing Cistern And Flush Pipes) Including Connection To Trap And To Flush Pipe Etc And Lime Concrete Bedding Including P Or S Trap Complete All As Specified And Directed. , M&L In Repairs Pvc Valve Less,Syphonic Action Type Flushing Cistern,Low Level ,White With Inlet Ball Valve,Float And Handle Including Brackets And Connection To Pipe And Fixing Of Chain And Pull Or Lever If Any Complete All As Specified And Directed. , S&F In Repair Vitreous China Wash Hand Basin White Flat Back, Size 550X400 Mm Including Bracket, Taps ,Waste Pipes , Chain And Plug Etc Complete All As Specified And Directed. , S & F In Repairs Pvc (Swr) Nani Trap / Floor Trap Plain Or Multi With Stainless Steel Grating Incl Joining To Waste Pipe With Solvent Cement Joint Dia Of Outlet 75Mm Bore Complete All As Specified And As Directed. , S&F In Repair 110Mm Bore Pvc (Swr) Bends Any Radius Complete All As Specified And As Directed. , S&F In Repair 75Mm Bore Pvc (Swr) Bends Any Radius Complete All As Specified And As Directed. , S & F In Repair 110 Mm Bore Pvc (Swr), Junction Single, (Single T) Equal Or Unequal Complete All As Specified And Directed. , S & F In Repair 75 Mm Bore Pvc (Swr), Junction Single, (Single T) Equal Or Unequal Complete All As Specified And Directed. , S & F In Repairs 110Mm Bore Pvc (Swr) Pipes Singles Socket In Any Length With Rubber Ring Joints Fixed To Walls / Floor Or In Trenches Complete All As Specified And As Directed. , S & F In Repairs 75Mm Bore Pvc (Swr) Pipes Singles Socket In Any Length With Rubber Ring Joints Fixed To Walls / Floor Or In Trenches Complete All As Specified And As Directed. , M & L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exc 10Cm Girth Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Dia Old Serviceable / Unserviceable Steel Tubing Any Grade And Connections Cleaning For Re-Fixing Or Removal To Store Complete All As Specified And Directed . , All As Per Item No 65 Above But 20Mm Bore Complete All As Specified And As Directed. , S&F Steel Tubing Medium Grade ,Galvanized With All Fitting Such As Bend ,Elbow, Socket,Tees,And Fixed Complete To Wall Or In Ceiling Or In Floors Including Cutting Threading And Making Forged Bends On Pipes Ms Hooks Etc ,For 15Mm Bore Pipes Complete All As Specified And As Directed. , All As Per Item No 67 Above But 20Mm Bore Complete All As Specified And As Directed. , S&F In Repair For 15Mm Bore Bib Taps Chromium Plated With Crutch Or Butterfly Handle ,Screwed Down , Screwed For Iron Pipes Or Brass Ferrule Complete All As Specified And Directed. , S&F In Repair Cp Angle Stop Cock Of 15Mm Bore Screwed Down For High Pressure With Crutch Or Butter Fly Handle ,Screwed Both End For Iron Pipes Complete All As Specified And Directed.. , S&F In Repair Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe 15Mm Bore Complete All As Specified And As Directed. , S&Fixed In Repair 125 Mm Size Chromium Plated Shower Rose With Siwel Joint Suitable For 15 Mm Bore Gi Pipes Complete All As Specified And Directed. , S&F In Repairs Pvc Connection 15Mm Size With Ptmt Nuts Of Length 450 Mm Long Complete All As Specified And As Directed. , S& F In Repair Rotational Moulded Polyethylene Water Storage Tank 1000 Liters Capacity (Cylidrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Incl Brass Float Valve 20Mm Dia And Dismantling Water Tank Complete All As Specified And Directed. , S & F In Shelf Of Ptmt Fixed With And Including Chromium Plated Brass Screws And Wooden/Plastic Cleats (Minimum Weight 300 Grams) Complete All As Specified And Directed. , S&F In Repair Stop Valves Fancy Type Chromium Plated With Long Shanks Fixed With 15 Mm Dia Bore Pipes Complete All As Specified And As Directed. , M & L High Strength Steel Deformed Tmt Bars 10 Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping Columns,Hookings Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.90 Mm Dia Or Securing With Clips, Etc Complete All As Specified And Directed. , M & L For Formwork Fair And Finished Surfaces To Sides And Soffits Of Floor Or Roof Beam, Beam Hauchings, Bands, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Complete All As Specified And Directed , M&L Reinforced Cement Concrete M-25 Using 20 Mm Graded Stone Aggr As In Beams, Bands, Cantilvers, Bressummers, Linters, Chajjas, Etc Over 1.5M Span Etc Complete All As Specified And Directed , Demolition And Breaking Up 150Mm Dia Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete ) And Set In Cement Mortar Complete All As Specified And Directed. , M&L For Concrete Bed To Drain Pipes Including Packing Under, And Haunching Against The Sides Of 150 Mm Bore Pipes In Cement Concrete 1:3:6 Type C-2 ( Using 40 Mm Graded Stone Aggregate) After They Are Laid And Tested Complete All As Specified And Directed. , M&L For 150 Mm Bore Salt Glazed Stone Were (Sgsw) Drain Pipe Grade A Laid To Slope In Tranches And Jointed In Cement Mortar (1:1) Including Necessary Testing For Ensuring Teak Proofing Complete All As Specified And Directed. , M & L For Cutting Into Existing Manhole For Connecting New Drains And Making Good To Pipes And Rendering Cutting Out Existing Benching For And Forming Branching For And Forming Branch Channel (1/2 Round Or ¼ Section ) In Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate Smooth Finished And Reforming Benching As Specified And Directed For 150Mm Dia Of Pipe Complete All As Specified And Directed. , M&L Plain Cement Concrete 1:4:8, Type B2( Using 40Mm Graded Stone Aggregate) 75Mm Thick As In Sub Base Of Floor Complete All As Specified And Directed . , M&L For 60Mm Thick Machine Pressed Precast Concrete Interlocking Paver Block (Glossy Finish) Of M-35 Gde Of Approved Shape, Size And Colour Conferming To Is 15658-2006 And Laid Over And Including 25Mm Thick Grid Cushion Complete All As Specified And Directed. , S & F For Precast Cement Concrete Type B-1 (1:2:4) (20Mm Graded Stone Aggregate) As In Kerb And Edging To Road And Footpath Etc, Including Chamfered, Weathering, Throating Etc And Setting In Cm (1:4) Complete All As Specified And Directed. , S & F In Repairs Ms Framed Work As In Doors Or Gates Of Angle Iron, Door Frame Or Other Section With Gusset Plate, Rails, Braces And Stair Case Etc Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering Etc, To Prepared For Hanging Or Sliding With Including Either Hooks And Hinges Also Fastening Grills, Grating, Hold Fast Of Doors And Windows Chowkat Etc, With Ends Of Bars Shouldered And Or Riveted, Or Forget Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walkways; Railings; Framework Of Water Tanksand Fixing And Similar Work Confirming To Fe 290 Gde E-165 Complete All As Specified And As Directed. , M&L For Preparation Of New Steel Surfaces Exc 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. , Excavation In Trenches N.Exc 1.5M Wide And N.Exc 1.5M In Depth For Foundation Or Etc, For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc N.Exc 10 Sqm On Plan And N.Exc 1.5M In Depth And Getting Out In Soft/Loose Soil, Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:4:8 Type D2, Using 40Mm Graded Stone Aggregate, As In Foundation Filing, And Mass Concrete , Etc Complete All As Specified And Directed , Removing Excavated Material (Soil) To A Distance Not. Exc. 50 Mtr And Depositing Where Directed At A Level Nexc 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. , M & L Cement Concrete Type B1 1:2:4 ( 20 Mm Graded Aggregate) As In Coping, Bearing Course, Manhole/ Drain Channels Etc In Including Necessary Formwork Complete All As Specified And Directed. , M&L For Cement Concrete 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggregatre As In Surface Channels And Drains Complete All As Specified And Directed. , Extra For Forming Fair Finished Drain Or Channel Exc 30 Cm Inner Girth In Cement Concrete, Using Extra Cement, Including Forms Moulds, Mitred/Stopped Ends Etc Complete All As Specified And Directed. , M & L For Preparing New Plastered Surface On Walls And Applying Three Coat Of White Wash Complete All As Specified And Directed. , M & L 20Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Steps, Jambs, Pillars, Window-Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite With Providing 15Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And As Directed.. , S&F In Repairs Standard Size Ewc White Colour With P/S Trap White Coloured With And Including Pvc White Coloured Seat Cover Including All And Connecting To Flushing Cistern Complete All As Specified And Directed. , Supply And Fixing Health Faucet Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete All As Specified And Directed. , S & F In Repair Soap Dish With Including Chromium Plated Brass Screws And Wooden/Plastic Cleats ( Minimum Weight 105Gm). Complete All As Specified And Directed. , S & F In Repair Tubular Towel Rail 20Mm Dia 600Mm Long Of Brass Chromium Plated Fixed With Including Chromium Plated Brass Screws And Wooden/Plastic Cleats Complete All As Specified And Directed. , Dismantling Of Asbestos Cement (Corrugated, Semicorrugated, Etc.) Sheets In Roof Covering Incl Ridges Etc Complete All As Specified And Directed. , S&F 0.50Mm Thick (Total Coated Thickness) Pre-Colour, Pre-Profiled Galvalume Sheets Of Required Colour And Design Having Tensile Strength Of 550 Mpa As In Roof, Wall Cladding, North Light Curves, Fixed With Zinc Coated Self Drilling Fastener Including Epdm Washer Complete Laid With One Corrugation Side Laps And Min 150Mm End Lap Laid To Slope All As Per Manufacturer/Profile Maker Instruction Complete All As Specified And Directed. , S & F Pre - Painted Galvalume Aluminium Zinc Coating Plain Sheeting 0.50 Mm Thick Of Required Colour And Shape Having Tensile Strength Of 550 Mpa As In Ridge Valley,Gutters,Barge Board,Roof Covering / Cladding To Wall, Fixed With Self Tapping Screwes Complete All As Specified And Directed. , S & F 600Mm X 450Mm Size Beveled Edge Mirror Of 6Mm Thick Selected Quality Mounted On 6Mm Thick Plywood With Chromium Plated Screws With Washer Complete All As Specified And Directed. , (Schedule-A Part-Ii E/M )Taking Down Carefully Unserviceable Aluminium Point Wiring Complete (Light, Fan Socket, Bell Or Power) With Fitting Such As Switches, Ceiling Rose Lamp Holder, Regulators, Sockets, Light Fittings Etc. And Keeping In Safe Custedy For Taking Credit Complete All As Specified And Directed. , (Schedule-A Part-Ii E/M )Taking Down Carefully Unserviceable Aluminium Point Wiring Complete (Light, Fan Socket, Bell Or Power) With Fitting Such As Switches, Ceiling Rose Lamp Holder, Regulators, Sockets, Light Fittings Etc. And Keeping In Safe Custedy For Taking Credit Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 2.68 Crore
Government Departments No of Bidders 1
5.
Heavy Industries and Public Enterprises #11454168 AOC
Bids Are invited for Custom Bid For Services - Rectification And Interior Modification Of 20 Ft Container For Office Use - Removal, Cleaning, And Re-Fixing Of Existing 2Mm Thick Gi Roofing Sheets Including Dismantling, Stacking, Surface Preparation, Re-Alignment, Fixing With Suitable Welding. , Providing And Fixing Interior False Ceiling Using Pvc Board (Min. 12Mm Thick) With Gi Framework Including Ceiling Sections, Perimeter Channels, Hangers, Fasteners, Joint Finishing And Surface Leveling Complete In All Aspects. , Supply And Installation Of App Modified Bitumen Waterproofing Membrane (Min. 3Mm Thick) Over Container Roof Including Surface Cleaning, Primer Application, Torching, Overlaps, Sealing And Edge Termination Complete In All Aspects. , Supply, And Installation Of Led Tube Lights (22W, 4 Ft) Complete With Fixtures, Internal Wiring And Connections Complete In All Aspects.Preferred Makes: Philips/ Crompton/ Havells Or Equivalent , Providing Complete Electrical Wiring Using Frls Copper Wires From Reputed Brand (1.5 Sq.Mm For Lighting & 2.5 Sq.Mm For Power As Per Site Required Length) In Pvc Conduit Including Saddles, Bends, Accessories And Termination Complete In All Aspects.Materials Shall Be Of Reputed Brand/Manufacturer Such As Polycab, Finolex, Havells, Rr Kabel Or Equivalent, Conforming To Relevant Is Standards And Isi Marked, Wherever Applicable. , Supply And Installation Of Modular 6A Switches From Reputed Brand Including Modular Plates, Flush/Surface Boxes And Wiring Connections Complete In Aspects.Materials Shall Be Of Reputed Brand/Manufacturer Such As Anchor, Legrand, Havells, Schneider Or Equivalent, Conforming To Relevant Standards And Isi Marked, Wherever Applicable. , Supply And Installation Of 6A, 5-Pin Modular Socket Outlets With Plates, Boxes And Wiring Complete In All Aspects.Materials Shall Be Of Reputed Brand/Manufacturer Such As Anchor, Legrand, Havells, Schneider Or Equivalent, Conforming To Applicable Standards And Isi Marked, Wherever Applicable. , Providing Ac Power Point With 20A Socket, Dp Switch, Mcb Protection And Wiring Using 4 Sq.Mm Wire Complete In All Aspects, Conforming To Relevant Standards. , Supply And Installation Of Rj45 Cat6 Io (02 Nos), Io Box (02 Nos), Jack (02 Nos) And Cat 6 Outdoor Cable (30M X 2Nos= 60 Rm) Including Cabling, Termination, Testing And Commissioning Complete In All Aspects. , Supply And Installation Of 4 Way Distribution Box 40 A Including Enclosure Box, Earthing, Termination Etc Complete In All Aspects. , Exterior Painting Including Surface Cleaning, Anti-Corrosive One Coat Primer And Two Coats Of Synthetic Enamel Paint On Outside Of The Containers. , Door And Window Repair Works Including Hinge Replacement, Alignment, Welding (If Required), Locking System Fixing As Per Site Requirement. , Supply And Fixing Of Complete Earth Pit System Comprising 32Mm Dia Gi Pipe (8 Ft. Length), 10 Meters Of Copper Earth Wire, 15 Kg Of Earth Enhancement Chemical, Brick Chamber (450Mm X 450Mm) With Plastering, And Heavy-Duty Manual Cover. The Work Includes Excavation, Installation, Backfilling, Connection, And Testing As Per Is 3043 Or Relevant Standards.
Contract Date: Ref. Documents Contract Value : 1.34 Lakh
Boards / Undertakings / PSU No of Bidders 3
7.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
8.
Defence #11413644 Technical Bid
Tender For Repair And Maintenance Of Chs Alongwith Connected Items At Various Units At Bhimbat,Thasgam & Drass Under Ge Kargil.- 1 Dismantling The Existing Burner Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed. 2 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For De- Carbonization , Descaling And Refractory Cement And Assemble The Same And Testing Complete All As Specified And Directed. 3 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr By Using Brush And Vaccum Cleaner Complete All As Specified And Directed. 4 M&L For Descaling Of Boiler By Circulating The Descaling Chemical Using Circulating Pump Into The Boiler And Kept It For Approx 4 Hours For Descaling And Flushing Off The Chemical After Descaling Of Boiler Complete All As Specified And Directed. 5 M&L For Refractory Cement / Heat Resistance Cement Of Boiler Assembly Of Heating Plant Complete All As Specified And Directed. 6 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 20Mm Complete All As Specified And Directed. 7 Supply And Fixing In Replacement Of Solenoid Valve Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 8 S&F In Repair Of Photo Cell Sensor Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Make - Cofi Complete All As Specified And Directed. 9 S&F In Repair Hydraulic Pressure Gauge Showing Reading 0-20 Bar With Accuracy +/- 2.5% To Be Connected With 15 Mm Dia Gi Pipe Complete With Suitable Size Of Battery Complete All Accessories And Protection Cover. 10 S&F In Repair Digital Temperature Controller (Dtc) Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 11 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 12 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 13 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 14 S&F In Repair Of Nozzel 60 Degree Complete All As Specified And Directed. Make : Danfoss Or Equivalents Make. 15 Replacement Of Old Unserviceable Minor Part For The Control Panel Including Repairing Of Wiring Etc As Per Existing, Complete All As Specified And Directed By Engr-In-Charge. 16 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 17 S&F In Repair Thermostat Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 18 S&Fin Repair Sequence Controller Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 19 S&F In Repair Contactor 25A, 230V/440V Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 20 S&F In Repair Of Contactor 230/ 440V Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 21 S&F In Repair Relay 4.5 - 7.5 Amps, 3 Phase, 50 Hz, 415 Volts Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 22 S&F In Repair Relay 6 - 10 Amps,3 Phase, 50Hz, 415 Volts Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 23 S&F In Repair Diesel Filter Assembly With Drain Port Complete As Per Sample. 24 S&F In Repair Fuel Pipe For Burner As Per Sample. 25 M&L For Complete Rewinding Of Electric Motor Of Capacity 5 Hp 3 Phase 415 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 26 M&L For Complete Rewinding Of Electric Motor Of Capacity 1 Hp Single Phase 230 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 27 All As Per Item No 26 Above But Capacity 0.5 Hp Single Phase 230 Volts. 28 Repair Of Chimney 7Mtr High Complete With Welding Including Iron Pieces, Plates, Outlet Cover And Necessary Modification And Cleaning Complete Removal Of All Kinds Of Dust Both Internal And External Parts And Free From All Kind Of Dust/Dirty Spots Of Chimney, Complete All As Specified And Directed By Engr-In-Charge. 29 M&L For Elastomeric Nitrile Rubber Foam Insulation Sheet For Ducts Having Anti Microbial Properties Having Thickness 10 Mm With Suitable Adhesive Complete All As Specified. 30 Dismantling Of Unserviceable/Damaged Hepa Filters And Supply And Fixing Of Hepa Filters With Al Box And Flange Type Of Size 640 X 460 X 50 Mm With Frame Having Efficiency Of 3 Microns Complete All As Specified. 31 M&L For Cleaning Of Existing Hepa Filters With Pressurized Potable Water By Using Pressure Pump And Water Spray Gun, Dry The Filters With Compressed Air After Cleaning Complete All As Specified. 32 Supply And Topping Up Of Antifreeze (Coolant) Suitable For -35 To -40 Degree Celsius To Be Filled In Reservoir Tank For Central Heating System As Instructed By Engr-In-Charge. 33 S&F Of Threaded Thermometer Having Range -50 To +100 Degree Celsius With Accuracy +/-2.5% To Be Fixed On 15 Mm Dia Gi Pipe Complete With All Accessories. 34 M&L For Rewinding Of Ahu Blower Motor Cap 5 Hp And Testing After Repair Complete All As Specified. 35 M&L Charges For Servicing Of Air Handling Units Including Blower Cleaning, Balancing Of Blower Motor Pully Complete All As Specified. 36 S&F In Replacement Of Supply Air Diffuser Alongwith Collar Damper Of Size 600 X 600, Neck Size 450 X 4550Mm All As Specified. 37 M&L For General Maintenance, Inspection And Servicing Of Chiller Unit By (Make-Bluestar Model No. Xac2S-010R2) Cleaning Of Condenser And Evaporator Coils Of The Chiller Unit By Using Specialized Cleaning Solution And Pressure Washing, Inspections Of The Compressor And Water Pump For Leaks, Noise, And Proper Functionality, Verifying The Integrity Of Electrical Components, Including Wiring, Breakers And Sensors, Parts, Lubrication Of Moving Parts, Checking Of Any Refrigerant Leaks, Checking Performance Testing And Optimization. 38 M&L For Repair/Replacement Of Faulty Components, Fixing Any Refrigerant Leaks And Vaccum Testing And Performance Evaluation After Refilling, Replacement Of Worn Out Gaskets, Seal And O-Rings For Chiller Of Capacity 9.2 Tr Complete All As Specified And Directed. 39 Supply And Charging Of Refrigerant Gas R-407C As Per Existing For Chiller Of Capacity 9.2 Tr And Testing After Charging Complete All As Specified And Directed. 40 Supply And Topping Up Of Compressor Oil As Per Existing Grade Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 41 Supply, Installation, Testing In Replacement Of Hermetic Type Scroll Compressor Unit , Suitable For 9.2 Tr Capacity Chiller Unit (Make-Bluestar Model No. Xac2S-010R2) Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Bluestar/Godrej / Lg Or Equivalent. 42 S&F In Replacement Of Expansion Valve As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 43 S&F In Replacement Of Filters & Driers As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 44 S&F In Replacement Of Pressure Switches As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 45 S&F In Replacement Of Control Relays As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 46 S&F In Replacement Of Fan Motor Of Cooling Tower As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 47 S&F In Replacement Of Temperature Controller As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 48 Dismantling The Existing Burner Assembly Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed By Engr-In-Charge. 49 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 30000 Kcal/ Hr For De- Carbonization And Assemble The Same And Testing Complete All As Specified And Directed By Engr-In-Charge. 50 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity Capacity 30000 Kcal/ Hr By Using Brush And Vaccum Cleaner Or Blower Complete All As Specified And Directed By Engr-In-Charge. 51 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Gun Metal Of Size 25Mm Complete All As Specified And Directed By Engr-In-Charge. 52 S&F In Repair Of Photo Cell Sensor Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr Complete All As Specified And Directed By Engr-In-Charge. 53 S&F In Repair Dtc Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 54 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 55 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 56 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 57 S&F In Repair Of Nozzel 60 Degree Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 58 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 59 S&F In Repair Thermostat Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 60 S&Fin Repair Sequence Controller Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 61 S&Fin Repair Solenoid Valve Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 62 S&F In Replacement Of Chimney Exhaust Of 6 Inch Dia Made Of Auminium Sheet Including Bends And Outlet Cover Complete All As Specified And Directed By Engr-In-Charge. 63 Dismantling The Existing Radiator Unit Of Capacity From 3000 To 6000 K Cal Per Hour, Taking It To Nearest Workshop Cleaning The Complete Unit With Coil Shine Chemical, Detecting The Leakage Portion By Applying Nitrogen Gas Pressure, Brazing The Leakage Portion, Refixing The Same Unit From Dismantled Location Including Testing On Load Complete All As Directed At Site By Engineer-In- Charge. 64 Supply And Laying 3 Layer (Inner Antimicrobial, Outer Uv Stabilized) Isi Marked Is-15801 Pp-R Pipe And Pp-R Plain Fittings In Walls Or Laying In Floors Complete Of Size Outer Dia 25 Mm Including All Fittings (Surface Remitting Also Included). 65 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 25Mm Complete All As Specified And Directed. 66 S & F In Replacement Thermostat Suitable For 126/165/195/310 Litres Capacity Refrigerators All As Directed. 67 Supply And Charging Of Refrigerant Gas As Per Existing For Refrigerator Of Capacity 126/165/195/310 And Deep Freezer Of Capacity 300/320/400/500 Ltr Capacity Including Testing After Application Of Nitrogen Gas Pressure To Find Out Any Leakage, Brazing And Stopping Of All Leakage Detected, Re-Application Of Nitorgen Pressure To Ensure Leak Proof Gas Circulator System Flushing Out The Nitrogen Gas Complete All As Specified And Directed. 68 S&F In Replacement Of Compressor Unit , Suitable For 165/195 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 69 S&F In Replacement Of Compressor Unit , Suitable For 126 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 70 S&F In Replacement Of Compressor Unit , Suitable For 310 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 71 S&F In Replacement Of Copper Capillary Tube With All Fittings For Refrigerator Of Cap 126/165/310 Ltr Complete All As Specified. 72 Repair To Voltage Stabilizer For Automatic Operation Single Phase Naturally Air Cooled, Indoor Type Designed For Output Variation Between 170 To 250 V With Output Voltage Stablized At 230 V With Accuracy Of +/- 2.5 % And Capacity 1 Kva And Making Connection With Ac Complete All As Specified & Directed. 73 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 50 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 74 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 25 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 75 M&L For Replacement Of Unservicible Inner Shell Made Of Stainless Steel 1.5Mm Thick Suitable For Geyser Inclusive Of Glass Wool As An Insulating Material For Geyser Of Capacity 25-50 Ltrs. 76 M&L For Replacement Of Thermostat For Geyser 0 To 80˚ C Complete All As Specified And As Directed By Engineer-In-Charge. 77 M&L For Flexible Pvc Connection Pipe For Geyser Of Length 1.5 Feet As Per Sample. 78 M&L For Replacement Of Pressure Release Valve For Geyser Of 25 Ltr Having Size 15Mm Dia. 79 M&L For Replacement Of Heating Element For 25 Ltr Geyser Capacity Round Type 1.5 Kw As Per Sample. 80 M&L For Replacement Of Heating Element For 25 Ltr Cap Triangle Type 1.5 Kw As Per Sample. 81 M&L For Replacement Of Geyser Assembly Suitable For 25 Ltr Geyser As Per Sample. 82 Repair And Replacement Of Kerosine Oil Batti Including Blower, Burner For Hammam 500 As Per Sample Complete All As Specified And Directed. 83 S&F Brass Tap Size15/20 Mm For Hamam As Per Sample Complete All As Specified And Directed. 84 M&L For Replacement Of Heating Element As Per Sample Suitable For 500Ltr Hammam As Per Sample. 85 S&F In Repair Of Compressor New Sealed Unit, Suitable For 300/320 Ltr Capacity Deep Freezer And Testing On Full Load Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete In All Respect Complete All As Specified And Directed By Engr-In-Charge.Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 16
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 1.49 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
10.
Housing Urban and Rular Development #11403465 Technical Bid
Tender for Procurement Of Mixed Flow Centrifugal Pump & Mud Pumps For Mitigation Of Urban Flooding Of Guwahati City , Supply, Installation & Commissioning Of Mixed Flow Pump Set With Discharge Range Of 270 - 250 Litre Per Second With Head Height 10.00 Mtr Coupled With 4 Pole 35-40Kw Motor Along With All Accessories. Application: Storm Water Discharge Capacity: 250 Lps Npshr: 5.30 M Viscosity: As Water Total Head: 10.00 Mtr Stages: Single Pump Efficiency: 80% To 85% Rated Speed: 1500 Rpm Impeller Diameter: 283 Mm To 338 Mm Motor Rating: 37.00 Kw Service Factor: 1.00, Frequency: 50 Hz Performance Testing Standard As Per Iso: 9906/Ansi-Hi 14.6 Gr 2B , Supply Of Ms Pipe Of 300 Mm Dia. Made From 6 Mm Thick Plate And Fitted With Flange In Both Ends With Hole For Fitting For Delivery Of Water From The Trolley Mounted Pump At The Rate Of 350 Ltr/Sec Of Discharge With Head 8-12 Mtr Complete As Directed. , Supply And Commissioning Of Kirloskar Make/Equivalent Taf2 Engine With Reputed Make Sp4l Mud Pump With Base Frame Coupling Type Complete Pump Set , Supply Of Pvc Suction Pipe 4 , Supply Of Gi Bend 4 , Supply Of Ci Tail Piece 4 , Supply Of Canvas Pipe 4 , Supply, Fixing & Installation Of Reputed Make 400 Mm_Pn 1.0_ Ci Nrv , Supply, Fixing & Installation Of Reputed Make 450 Mm_Pn 1.0_ Ci Nrv , Supply, Fixing & Installation Of Reputed Make 400 Mm_Pn 10_ Ci Bfv , Supply, Fixing & Installation Of Kbl Make 450 Mm_Pn 10_ Ci Bfv , Supply, Fixing & Installation Of Reputed Make 5Hp Vacuum Pump Set
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
12.
Housing Urban and Rular Development #11346479 Technical Bid
Tender for Construction Of Modular Ot Eye Under Old Sadar Hospital At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
13.
Housing Urban and Rular Development #11346477 Technical Bid
Tender for Construction Of Modular Ot (Eye) Under Sub Divisional Hospital At Madhupur Dist Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
14.
Housing Urban and Rular Development #11346476 Technical Bid
Tender for Construction Of Modular Ot (General & Gynae) At Chc Under Sarwan Block At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Multi Purpose Ot Table With C - Arm Compitable , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro-Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
15.
Public Administrative Department #11335414 AOC
Tender For Working at Kamala Nehru Hospital under Urban 95 Baby Friendly Hospital-ITEM NO: 1 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. ( SSR Item No: 23.01 ) (PMC Bhavan) Unique No (15297) Rate List Year (2024-2025) ITEM NO: 2 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. (SSR Item No: 46.09) (PMC Bhavan) Unique No (16016) Rate List Year (2024-2025) ITEM NO: 3 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. (SSR Item No: 46.29) (PMC Bhavan) Unique No (16034) Rate List Year (2024-2025) ITEM NO: 4 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (SSR Item No: 24.04) (PMC Bhavan) Unique No (15309) Rate List Year (2024-2025) ITEM NO: 5 Providing first class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth including bailing out water manually, striking joints on unexposed faces, pointing with cement mortar 1:3 on exposed face and watering etc. Complete. (SSR Item No: 27.02) (PMC Bhavan) Unique No (15371) Rate List Year (2024-2025) ITEM NO: 6 Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. (SSR Item No: 2.09) (PMC ROAD) Item Spec: (MORTH 201) Unique No (86) Rate List Year (2023-2024) ITEM NO: 7 Supplying soft murum at the road site, including conveying and stacking complete. (SSR Item No: 2.29b) (PMC ROAD) Unique No (104) Rate List Year (2023-2024) ITEM NO: 8 Spreading hard murum/ soft murrum/ gravel or kankar for side width complete (SSR Item No: 2.30) (PMC ROAD) Unique No (105) Rate List Year (2023-2024) ITEM NO: 9 Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. (SSR Item No: 2.31) (PMC ROAD) Unique No (106) Rate List Year (2023-2024) ITEM NO: 10 Pervious Concrete Paver Block: 80 mm thickness having porosity 15 to 20% and concrete grade M-30 supply transportation, and fixin on site with all material, transportation, labour all including. (SSR Item No: 1.11) (PMC ROAD) Unique No (205) Rate List Year (2023-2024) ITEM NO: 11 Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb with gutter (as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant (SSR Item No: 7.04) (PMC ROAD) Item Spec: (MORTH 408) Unique No (380) Rate List Year (2023-2024) 25 ITEM NO: 12 Providing and fixing Guard Railing of 1000mm height as per Type D Drg. No. 15 dt. 20-4-79, and fixed in 40 x 40 x 6mm iron, angle embedded in 1:2:4 cement concrete bedding patti as per detailed drawing, with 3 coats of approved of yellow and black paint. (SSR Item No: 7.09) (PMC ROAD) Item Spec: (RD) Unique No (385) Rate List Year (2023-2024) ITEM NO: 13 Transportation of material obtained from excavation including soil, Cu.M rubble, bricks, RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. As directed by Engineer In charge (SSR Item No: 78.36) (PMC Bhavan) Unique No (17223) Rate List Year (2024-2025) ITEM NO: 14 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (SSR Item No: 32.11) (PMC Bhavan) Unique No (15444) Rate List Year (2024-2025) ITEM NO: 15 Providing and applying priming coat on concrete/ masonary/Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR Item No: 35.21) (PMC Bhavan) Unique No (15571) Rate List Year (2024-2025) 2. ITEM NO: 16 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (SSR Item No: 32.34) (PMC Bhavan) Unique No (15466) Rate List Year (2024-2025) ITEM NO: 17 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. (SSR Item No: 36.11) (PMC Bhavan) Unique No (15587) Rate List Year (2024-2025) ITEM NO: 18 Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. (SSR Item No: 35.09) (PMC Bhavan) Unique No (15560) Rate List Year (2024-2025) ITEM NO: 19 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning,preparing the plaster surface ,applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary (SSR Item No: 35.26) (PMC Bhavan) Unique No (15576) Rate List Year (2024-2025) ITEM NO: 20 Providing and fixing 12 mm thick waterproof plywood (durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI)) (SSR Item No: 62.11) (PMC Bhavan) Unique No (16542) Rate List Year (2024-2025) ITEM NO: 21 Providing and fixing 19 mm thick waterproof plywood (durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI)) (SSR Item No: 62.12) (PMC Bhavan) Unique No (16543) Rate List Year (2024-2025) ITEM NO: 22 Wall Painting art work painting artistic work on any type of surface and at any height using scaffolding with skilled artists as per the instructions of site incharge.measurement will be as per actual max.size of art.rate for background apex paint and lettring will be paid seperately (SSR Item No: 63.4) (PMC Bhavan) Unique No (16694) Rate List Year (2024-2025) ITEM NO: 23 Providing & Fixing in position, MS fabrication work using angles, sqr tubes, c channels etc for various partition frame as per Design & Instructions & Complete in all aspects including all materials labour, finishing etc complete (SSR Item No: 51.16) (PMC Bhavan) Unique No (16167) Rate List Year (2024-2025) 6 ITEM NO: 24 Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes.complete. (SSR Item No: 6.12a) (PMC ROAD) Item Spec: (MORTH 803.4) Unique No (251) Rate List Year (2023-2024) ITEM NO: 25 Stamped Concrete :- Thin overlay approximately 1/32 to 5/16 (thicker application may be nessecery in some situations) of stamped concrete overlays over M-20 concrete of 100 mm thick-surface, interior, applied smooth, textured or stamped in various patterns and designs using stamps and seamless texture skins, then antiqued, chemically stained or integrally colored and sealed with the appropriate coating. Systems sealers or protective top coats according to the job conditions and specifications. (including the cost of M-20 concrete of 100 mm thickness) (SSR Item No: 1.10) (PMC ROAD) Unique No (204) Rate List Year (2023-2024) ITEM NO: 26 Providing & fixing BENCH IN CEMENT MORTOR/CONCRETE WITH WOODEN FINISHING ON ALL EXTERNAL SURFACE. Bench should have min. 2.1m to max. length 2.4m with 0.45m wide seat & 0.40m high back for resting. beach should have 2 to 3 supports/Legs as per requirement from ground in 1:1.5:3 ratio Concrete with 4 bar 12mm as a main & distribution 8mm Tor steel at 150mm c/c. Rate includes proper cleaning of surface by sand paper application of 1 coat of Apex exterior grade primer above that 2 coat of exterior grade Apex Paint as a base coat & 1 coat of Apex Paint for making wooden finish/grains & with 2 final coat of Apex clear polish including Cement, Sand, Aggregate, chemical, adhesive, chickenmesh, primer, paint, polish, paper, etc. all material, labor, scaffolding, excavation, pcc, tor steel etc. all complete. Work done should be as per a approved sample & the instructions of engineer incharge. (SSR Item No: 3) (PMC Garden) Unique No (19719) Rate List Year (2024-2025) ITEM NO: 27 PROVIDING and laying Natural River Sand in Play Area or required locations in Gardens, as per the instructions given by the Engineer Incharge, inclusive of material, Labour, Transportation,, etc all complete. (SSR Item No: 10) (PMC Garden) Unique No (19726) Rate List Year (2024-2025) ITEM NO: 28 Providing and fixing N.H./ S.H. Route Marker size 60 cm x 45 cm with one No. direction plate of size 30 cm x 25 cm prepared on 16 guage Alluminium sheet including Type IV High Intensity Micro-Prismatic Grade Sheeting (HIP) having pressure sensitive/ heat activated adhesive, IRC Specified colour retro reflective cutout border & messages having pressure sensitive adhesive having border & messages in IRC Specified colour background, including one One Number of M.S. Angle iron post of size 50 x 50 x 5 mm of 3.65 m. long inflated at bottom drilled on top in one piece without joint painted with white and black bands of 30 cm. fixing board and post with 4 Nos. of high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in-charge etc. complete. Alluminium sheet Type IV High Intensity Micro-Prismatic Grade Sheeting (SSR Item No: 6.54) (PMC ROAD) Item Spec: (IRC-67 2012) Unique No (339) Rate List Year (2023-2024) ITEM NO: 29 DOUBLE POST SWING (Proving and Fixing) Rec. Age :- 4-14 yrs. The area :- 3.5 x 1.0m Safe play area :- 4. X 2.0m The leg supports of the single post swing is made up of 150 NB while the top bar is of 50 NB GI pipes. The Gl pipes are powder coated. All pipes are A class pipes, The two swings are made up of 10mm thick skid reinforced. The seats of the single support swing are made up of 10 mm thk rubber with anti skid. The rubber seat is suspended on 6mm thk gi chain. The ball bearings of brands like SKF, FAQ are mounted inside a specially designed nylon clamp. All pipes are B class pipes All Structures are to be Powder Coated. All Work Done As Per General Raw Material Sheet Added Below. Work done should be as per Engineer incharge Instructions (SSR Item No: 3) (PMC Garden) Unique No (19526) Rate List Year (2024-2025) ITEM NO: 30 FROG BIN DUSTBIN (Proving and Fixing) Height: - 850 mm Dia : 600 mm This fish is made in pure polyester Fiberglass Reinforced Plastic of 2mm thk with MAT finish to give it a mirror image and it is corrosion resistance. This attractive frog shape attracts children towards it because of its eyes, hands, legs. As the children have habit of throwing the trash on the road or in the park, this encourages children to avoid littering, which creates an unhealthy and aesthetically unpleasant social environment. The trash is to be put through the mouth of the frog. Work done should be as per Engineer incharge Instructions. (SSR Item No: 73) (PMC Garden) Unique No (19596) Rate List Year (2024-2025) ITEM NO: 31 Providing and Installing EPDM (Ethylene Propylene Diene Monomer) Rubber flooring19mm thickness would be made of Black Styrene Butadiene Rubber for buffing purpose System with thickness upto 25 mm consisting of sandwich two layers, base layer having and top finished layer of 6 mm would be made of size 1-4 mm Ethylène Propylene Diene Monomer with 1 year Warranty. 2745.00/- Per Sq.m (Excluding G.S.T.) (SSR Item No: 72.6) (PMC Bhavan) Unique No (17101) Rate List Year (2024-2025) ITEM NO: 32 Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. (SSR Item No: 27.12) (PMC Bhavan) Inique No (15380) Rate List Year (2024-2025)
Contract Date: Jun 22, 2026 Contract Value : 27.64 Lakh
Local Bodies No of Bidders 7
Maharashtra View Result →
16.
Power #11334917 AOC
Tit-bit civil work along with Repair and Maintenance of Chakdha (west) CCC Building. (Estimate as per P.W.D. S.O.R.Vol I &II for the area of Kalyani Sub-Division in the district of Nadia w.e.f. 01.11.17 and all other corrigenda uptodate ) - 1 Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m .a) In ground floor including roof 2 b) In first floor 3 Dismantling all types of masonry excepting cementconcrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directedwithin a lead of 75 m.a) In ground floor including roof 4 b) In first floor 5 Dismantling all types of plain cement concreteworks, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75m.In ground floor including roof.(a) upto 150 mm. thick 6 b) In first floor 7 Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof 8 b) In first floor 9 Earth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necess-ary trimming thesides of trenches, levelling, dress-ing and ramming thebottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm 10 Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis ofmeasurement of finished quantity of work)(a) With earth obtained from excavation of foundation 11 Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. 12 Cutting holes and subsequent mending good damages. (a) Diameter upto 150 mm. (i) In brick work [Cement-4.0 Kg/Mtr] 13 Cutting chase upto 125 x 150 mm. and subsequentmending of damages.(a) in brick wall [Cement-3.6 Kg/Mtr] 14 Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineerin charge. 15 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 16 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any as per relevant IS codes. a) Pakur Varietya) In ground floor 17 b) In first floor 18 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominalsize) excluding shuttering and reinforcement,if any, in gound floor as perrelevant IS codesPakur variety 19 1st floor 20 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Varietya) In ground floor 21 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.a) For works in foundation, basement and upto roof of ground floor / upto 4m.(iii) other manufacturers not specified. 22 Brick work with 1st class bricks in cement mortar (1:6)a)in foundation & plinth 23 In Super structure, ground floor 24 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.a) In ground floor 25 b) In first floor 26 Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.(B) Wall-------------------------With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m-----------ii) Other than Coloured decorative including white----------i) Gr.floor 27 A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m& joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m----- Other than Coloured decorative including white-------i) Gr.floor 28 Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cementmortar (1:4) and 2 mm thick cement slurry back side of tilesusing cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course) laid afterapplication slurry using 1.75 Kg of cement per sqM belowmortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxygrout materials of approved make as directed and removal ofwax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finishcomplete including the cost of materials, labour and all otherincidental charges complete true to themanufacturer sspecification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be suppliedby the contrr]e)I(I) With application slurry @1.75 kg/ Sq.m, 20 mm sandcement mortar (1:4) & 2 mm thick cement slurry at back sideof tiles, 0.2 kg/ Sq.m white cement for joint filling withpigment.(A) Light colour(Gr.floor) 29 (ii) First floor 30 Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick)----------(i) Ground floor 31 In 1sl floor 32 Labour for taking out door and window frame including shutter for repair orreplacement of different parts of the frame & refixing the same including mendinggood all damaes complete. (Concrete and brick work for mending damage will bepaid separately)(a) Upto area 2.5 Sq.m 33 M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S. W.I. flats and bars for windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.i) Grill weighing above 16 Kg./sqm------------a) In ground floor 34 b) In first floor 35 Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) 36 1st floor 37 M.S. structural works in columns, beams etc. with simple rolledstructural members (e.g. joists, angle, channel sections conformingto IS: 226, IS: 808 & SP (6)- 1964 connected to one another withbracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming toIS: 816- 1969 & IS: 1995 using electrodes of approved make andbrand conforming to IS:814- 2004, haulage, hoisting and erectionall complete. The rate includes the cost of rolled steel section,consumables such as electrodes, gas and hire charge of all tools andplants and labour required for the work including all incidentalchages such as electricity charges, labour insurance charges etc 38 Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufacture from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position,straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing fixed with neceessary clamps and nuts and bolts and erected complete.(ii) below 50mm.Fixed type steel windows as per IS sizes with horizontal glazing bars 39 (b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only] 40 steel peg stay 300 mm long including fitting and fixing. 41 Two point nose steel handle including fitting and fixing. 42 Taking out M.S. or W.I. Grills from wooden frame including cuttinglugs from masonry wall and refitting the same and mending gooddamages after repairs. (Excluding the cost of necessary repair ofdamages) or doing any other necessary works 43 Easing, oiling and adjusting the steel shutters including scraping allmembers and fitting so as to make the shutters easily operable (noextra payment will be made for taking out and fixing glass, ifnecessary). 44 Renewing M.S. members of steel shutters by welding including takingout the old, mending good damages complete, including taking outand refixing the glass panes. 45 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(c) Sal : Locala) In ground floor 46 Panel shutters of door and window, as per design (each panel consisting of singleplank without joint), including fitting and fixing the same in position butexcluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. 47 Brass floor door stopper. 48 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed. a) With continuous plate base (Hexagonal / Round rod), (i)75 mm grip x 10 mm dia rod. 49 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark.vi) 100mm. X 75mm. X 3.5 mm 50 Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixedwith cadmium plated screws:ix) 300mm long x 10mm dia. bolt. 51 Anodised aluminium Aldrop / Sliding bolts of approved quality manufacturedfrom extruded section conforming to I.S. specification (I.S. 2681/66) fitted andfixed complete.----------300mm x 16mm dia. Bolt 52 Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. 53 PVC Door Shutter-37 mm thick-Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt,door ring etc. In ground floor. 54 Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work).In 10-12 Micron thickness Annodizing film. i)natural White k) Movable door shutter .Door frame (top & sides) 55 ii) Shutter :Top rail 56 Bottom rail 57 Door Vertical 58 Lock rail 59 Glazing cleap 60 Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections for the following units:- (B) Partly glazed partly panelled or fully glazed single leaf alunminiumswing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry setneoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. 61 Supplying bubble free float glass of approved make and brandconforming to IS: 2835-1987. i) 4mm thick clear glass. 62 5mm thick clear glass 63 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filledwith foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) . (b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) 64 Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work).(A) In 10-12 Micron thickness Annodizing film. i)natural White j)Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both endsof vertical member restrained but panels within 0.9 sq.m.)Top,bottom & side member 65 Intermediate member. 66 Glazing clip. 67 Supplying heavy duty hydraulic double action floor spring along with toppin/set of pivots conforming to IS: 6315 or any approved make as perdirection of Engineer in charge. 68 Supplying heavy duty top pin/set of pivots of local make and approved by the Engineer-in-charge. (This item to be provided where floor spring not 69 Supplying concealed type heavy duty PVC headed aluminium tower boltfor double leaf doors as per approved make and brand as per direction ofEngineer-in-Charge.250 long 70 Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.(weatger gasket/woolpile) 71 Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width 72 Extra for each additional floor. 73 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including, rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including threading nosing and drip course where necessary.i) With 1:6 cement mortar.a) 20 mm thick plaster.in ground floor 74 a.2) In first floor 75 15 mm th.b.1) In ground floor. 76 b.2) In first floor 77 ii) With 1:4 cement mortar.c) 10 mm thick plaster.c.1) In ground floor 78 Neat cement punning about 1.5mm. thick in wall, dado, window sills, floor, drain etc. 79 Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) 80 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)i) Standard Quality 81 Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturers specification and as per direction of E.I.C(i)One coat in ground floor 82 2) In first floor 83 Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.b) NORMAL Acrylic Emulsionin ground floor(two coat) 84 2) In first floor(Two coat) 85 Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. 86 a ) Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) 87 b ) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) 88 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) 89 (b) On steel or other metal surface :--------With super gloss (hi-gloss) ------(iv) Two coats (with any shade except white) 90 (iii) One coat (with any shade except white) 91 Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (i) 3 mm thick (weighing 7.4 kg/Sq.m) 92 (ii) 4 mm thick 93 Renewing worn out putty of glass panes :(a) Panes not exceeding 0.2 Sq.m 94 Supply fitting approved type ventilator in position after cutting holes in walls setting in cement mortar, mending damages to wall and plaster and two costs of point of approved brand and shade.(b) R.C.C ventilator of 20 mm. thicki) Upto 0.10 Sqm. Area 95 Artificial stone in floor, dado, staircase etc with cement concrete(1:2:4) with stone chips, laid in panels as directed with toppingmade with ordinary or white cement In ground floor. (as necessary) and marble3 mm. thick topping (High polishing grinding on this item is notpermitted with ordinary cement).(ii) 25 mm th.(i) Ground floor 96 Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wallafter unscrewing bolts, nuts, screws etc.andstacking the material at site as directed. 97 Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor)(i) In Roof:-b) With 0.60 mm thick sheet 98 (ii) In wall:-a) With 0.60 mm thick sheet 99 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. 100 (f) 25 mm to 30 mm shuttering without staging in foundation 101 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining withjointing materails (SpunYarn,Valamoi/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. 102 B) UPVC Fittings:a) Plain Tee(ii) 110 mm. Dia 103 b) Plain Y(ii) 110 mm. Dia 104 c) Bend 87.5 degree (ii) 110 mm. Dia 105 d) Shoe c(ii) 110 mm. Dia. 106 Uprooting and removing plants from the surface of wallsparapet etc and making good damages. (Repairing ofdamages to be paid separately) 107 Renewing throating,nosing or drip course moulding with 15 mm.thick cement plaster (1:4) complete. (Cement 0.7Kg/Mtr.)In ground floor. 108 Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in- Charge prior to execution will be necessary).(Payment to be made on area cleared) 109 Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union cross, elbow nipple, long screw reducting socket reducing tee, short piece etc. fitted withholder bats clamps, including cutting pipes, making threads, fitting fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground (payment will be made on the center line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials) FOR EXPOSED WORK15MM DIA MEDIUM QUALITY 110 ii) 20 mm dia medium quality 111 ii) 25 mm dia medium quality 112 Chromium plated round shower with revolving joint (Equivalent toCode No. 541(N) & Model - Tropical / Sumthing Special of ESSCO orsimilar brand). 113 Supplying, fitting and fixingpillar cock ofapproved make---CP pillar cock-15mm(Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand) 114 Supplying, fitting, fixing G.M wheel valve of approved brand and made tested to 21 Kg. Per sq. cm. (for water lines only.) --- i)20mm. 115 ii)25mm 116 11)40mm 117 Supplying fitting fixing bib cock Chromium plated Bib Cock short body (Equivalent to Code No. 511& Model - Tropical / Sumthing Special of ESSCO or similar brand). 118 b)i.Chromium plated Stop cock [Equivalent to Code No.513(A) & 513(B) & Model - Tropical/Sumthing of ESSCO or similar brand] 119 Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver redas per I.S. 3438 / 1965 together with brass C.P. hinges.(i) 450 mm X 300 mm 120 Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. b) With S trap (with vent) 121 Supplying, fitting and fixing towel rail with two brackets.a) C.P. over brass.b) I) 25 mm dia and 450 mm long 122 Supplying, fitting and fixing 18 mm. thick marble partition slab with chawk doongri marble square cut, both sides polished with two front corners rounded and edges polished. 123 Supplying, fitting and fixing white vitreous china best quality approvedmake wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillarcock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approvedquality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approvedquality P.V.C. connection pipe with heavy brass C.P. nut includingmending good all damages and painting the brackets with two coats ofapproved paint.(i) 450 mm X 300 mm size 124 Supplying, fitting and fixing Orissa pattern water closet in white glazedvitreous chinaware of approved make in position complete excluding P orS trap (excluding cost of concrete for fixing).(i) 580 mm X 440 mm each 125 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. Specification withP.V.C fitting complete, C.I. brackets including two coats of painting to bracket etc. 126 Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make withnecessary fixing materials and clamps complete.i) Polythene Flush Pipe 127 Flat back urinal (half-stallin urinal)in white vitreous china ware of approved make (CERA/HINDWARE)supplied,fitted and fixed in position with brass screw on75mmx75mmx75mm wooden block complete. (i) 635 mm X 395 mm X 420 mm each 128 Supplying ,fitting and fixing approved brand p.v.c. connector white flexible ,with both ends coupling with heavy brass C.P.nut 15mm dia.(i) 300 mm long 129 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps.900 mm long 130 Approved patent vent cowl I.C.I. conforming to I.S.S.a) 75 mm dia. 131 Supplying PVC water storage tank approved quality with closed top with lid (block). Multilayer. a) 1500 Litre capacity. 132 Labour for dismantling (i) 15 mm 133 (ii) 20 mm 134 100 mm 135 Refixing GI pipe with fittings with cleaning wher necessary(i) 15 mm 136 (ii) 20 mm 137 Removing chokage in G.I pipe including cleaning pipe(i) 15 mm 138 (ii) 20 mm 139 Renewing C.I. clamp for pipe including cutting hole in wall etc. and mending good all damages with cement concrete(4:2:1) with jhama chips and cement plaster (6:1) to match with and curing.15mm 140 (ii) 20 mm 141 Dismantling wash basin with brackets with or without waste fittings. 142 Dismantling E.P. or Anglo-Indian W.C. 143 Dismantling urinal. 144 Dismantling pillar cock of wash basin. 145 Cleaning glazed tiles with acid 146 Mazdoor 147 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings asrequired,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separatepayment will be made for accesories, specials. Payment for painting willbe made seperately)(a) For Exposed Work PVC Pipes 15mm 148 20 mm metredia 149 25 mm metredia 150 40 mm metredia 151 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm 152 Supplying, fitting and fixing 15 mm swan neck tap with left & right handoperating nob with aerator (Equivalent to Code No. 510, 510(A) andModel - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand 153 Iron door ring of approved quality fitted and fixed with nut and washer complete. (i) 50mm dia. 154 Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick) 155 ii) Godrej Hydraulic door closer fitted and fixed complete.(c) Light type 156 Filling in foundation or plinth by fine sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) 157 Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.(a) Upto 20 users:-(ii) Beyond a lead of 150 metre and outside the Municipal limit 158 Cleaning rubbish, sludge, weeds scum, liquid earth, mud etc.etc.from road side masonary drain/ hume pipe drain/ culvert etc. by mathor labour after removing concrete.Slab/manhole cover etc.without damaging the same and refixing the same properly after cleaning as necessary and removing the sludge etc.etc.by using iron pans,buckets including all labour, tools & plants including removing the spoils in dry condition and disposing the same by truck beyond the road side in conformity with municipal/corporation rules for such disposal including loading into truck and cleaning the road side in all respects as per direction of the Engineerin-Charge. 159 Renewing profile of rolling shutter including fitting fixing complete as per existing size and shape 160 Labour for taking out rolling shutter (only shutter portion) dismantling by parts for repair or (replacement of damaged parts only), rehanging and refitting the same in position after necessary repairs (excluding the cost of supply of new parts 161 Easing and oiling, cleaning collapsible gate and repairing to locking arrangements. 162 Easing and oiling, cleaning rolling shutters excluding repair to inside locks 163 Easing and oiling W.I. Gate or G.I. Gate. 164 Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L. 165 Extra for each additional story 166 Labour for lowering plastic water storage tank and stacking in places asdirected.(i) Upto 1500 litre capacity 167 (b) Extra for each additional story 168 Labour for punching hole in plastic water storage tank upto 50 mm dia 169 Labour for taking out (from fencing) line of wire (galvanised,strand or barbed) by drawing the same out through holes in thebody of the post or through holes formed by fixed staples.(Payment to be made on the length of the wire taken out.) 170 ) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line ofbarbed wire in fencing (holes already made in the body of the post)or fixed by staples tightening and fixing the wires in taut conditionwith straining bolts including the cost of cutting and of lappingjoints in the wire as necessary but excluding the cost of galvanisedstaples,straining bolt and binding wire where necessary. 171 Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete. (i) 10 mm. dia. (a) 150 mm 172 Supplying galvanised staples fitted and fixed complete. (a) 19 mm. to 25 mm. size
Contract Date: Jun 23, 2026 Contract Value : 5.85 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
17.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
21.
Communications and Information Technology  #11304653 Technical Bid
Tender for Name Of The Bidder S. No. Item Code Item Qty Qty Unit Unit Rate Amount Inclusive Of Gst Amount In Words Schedule () A-Schedule , Description:- Installation Of Ofc Joint Enclosure And Splicing & Testing Of 48 Fiber Ofc Cable As Per Technical Specification Ts-4. Description:- Installation Of Ofc Joint Enclosure And Splicing & Testing Of 48 Fiber Ofc Cable As Per Technical Specification Ts-4. , Description:- Digging Of 1.20 Meter Deep And 0.3 Meter Wide Trenches Including Clearing Of Roots Of Trees And Bushes And Temporary Obstruction On The Selected Route, As Per Technical Specifications And Cable Route Plan. Note: In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Wide Is Not Possible Or Bigger Size Trench Is Required To Lay More Cables Or Loose Soil/ Muck Is Encountered, The Depth Can Be Reduced / Increased As Per Directions Of The Engineer-In-Charge Of The Works, The Payment Will Be Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide. In All Type Of Soils Including Soft Rock. Note: In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Wide Is Not Possible Or Bigger Size Trench Is Required To Lay More Cables Or Loose Soil/ Muck Is Encountered, The Depth Can Be Reduced / Increased As Per Directions Of The Engineer-In-Charge Of The Works, The Payment Will Be Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide. In All Type Of Soils Including Soft Rock As Per Ts-5. Description:- Digging Of 1.20 Meter Deep And 0.3 Meter Wide Trenches Including Clearing Of Roots Of Trees And Bushes And Temporary Obstruction On The Selected Route, As Per Technical Specifications And Cable Route Plan. Note: In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Wide Is Not Possible Or Bigger Size Trench Is Required To Lay More Cables Or Loose Soil/ Muck Is Encountered, The Depth Can Be Reduced / Increased As Per Directions Of The Engineer-In-Charge Of The Works, The Payment Will Be Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide. In All Type Of Soils Including Soft Rock. Note: In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Wide Is Not Possible Or Bigger Size Trench Is Required To Lay More Cables Or Loose Soil/ Muck Is Encountered, The Depth Can Be Reduced / Increased As Per Directions Of The Engineer-In-Charge Of The Works, The Payment Will Be Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide. In All Type Of Soils Including Soft Rock As Per Ts-5. , Description:- Excavation Of Trench To A Depth Of 1 Mtr. For Track Crossing Of Cables, Laying Of Hdpe/Dwc/ Reinforced Cement Concrete Pipes With Collar/Coupling, Refilling Of Trench By Ramming And Consolidating It As Per The Instructions Of Railway Representative At Site. During Excavation Of Trench It Has To Be Ensured That The Excavated Soil Does Not Mix With The Ballast Available. The Depth Of 1M Trench Shall Be From The Bottom Of Sleepers For Track Crossings As Per Ts-6. Description:- Excavation Of Trench To A Depth Of 1 Mtr. For Track Crossing Of Cables, Laying Of Hdpe/Dwc/ Reinforced Cement Concrete Pipes With Collar/Coupling, Refilling Of Trench By Ramming And Consolidating It As Per The Instructions Of Railway Representative At Site. During Excavation Of Trench It Has To Be Ensured That The Excavated Soil Does Not Mix With The Ballast Available. The Depth Of 1M Trench Shall Be From The Bottom Of Sleepers For Track Crossings As Per Ts-6. , Description:- All Works Of Excavation Of Cable Trench 1.0 Meter Deep, 0.3 Meter Wide On Pucca Platform/On Road For Road Crossing And Restoration Of The Platform/Road Surface To Original Condition With Contractors Material, After Laying Of Gi/Dwc Pipes And Then Re-Fill As Per Ts-7. Description:- All Works Of Excavation Of Cable Trench 1.0 Meter Deep, 0.3 Meter Wide On Pucca Platform/On Road For Road Crossing And Restoration Of The Platform/Road Surface To Original Condition With Contractors Material, After Laying Of Gi/Dwc Pipes And Then Re-Fill As Per Ts-7. , Description:- Transportation Of Hdd Machine With Accessories Including Handling Of Stores Materials, Supply Of Hdpe/Dwc Pipe Of Adequate Dia. Sizes As Per Instruction Of Engineer In Charge, Preparation Of Site, Entry, And Exit Pit(1Mx1mx1m) And Boring Of Size 110 Mm Dia. For Placing Of Hdpe Silicore Duct/Dwc Of Adequate Dia. Size As Per Instruction Of Site Engineer For 6 Quad Cable/Ofc Cable /Other Cables For Crossing Track/Pucca Road /Congested Area. Boring Trench Shall Be Minimum 3(Three) Meter Below The River Bed/Track And 1(One) Meter Below The Road/Pucca Roadcrossing Area Including Supply Of Accessories For Pulling Hdpe Pipe. All Other Petty Materials With Earth Work, Jointing Of The Duct Is To Be Done By Contractor As Per Ts-8. Description:- Transportation Of Hdd Machine With Accessories Including Handling Of Stores Materials, Supply Of Hdpe/Dwc Pipe Of Adequate Dia. Sizes As Per Instruction Of Engineer In Charge, Preparation Of Site, Entry, And Exit Pit(1Mx1mx1m) And Boring Of Size 110 Mm Dia. For Placing Of Hdpe Silicore Duct/Dwc Of Adequate Dia. Size As Per Instruction Of Site Engineer For 6 Quad Cable/Ofc Cable /Other Cables For Crossing Track/Pucca Road /Congested Area. Boring Trench Shall Be Minimum 3(Three) Meter Below The River Bed/Track And 1(One) Meter Below The Road/Pucca Roadcrossing Area Including Supply Of Accessories For Pulling Hdpe Pipe. All Other Petty Materials With Earth Work, Jointing Of The Duct Is To Be Done By Contractor As Per Ts-8. , Description:- Laying Of Hdpe/Dwc Pipe Of Various Sizes - As Advised By Engineer-In-Charge And As Per Ts-9. Description:- Laying Of Hdpe/Dwc Pipe Of Various Sizes - As Advised By Engineer-In-Charge And As Per Ts-9. , Description:- Blowing Of Ofc Through Hdpe Pipe For 48 Fiber Ofc Cable As Per Ts-10 Description:- Blowing Of Ofc Through Hdpe Pipe For 48 Fiber Ofc Cable As Per Ts-10 , Description:- Back Filling And Consolidating Of Cable Trench First For 5 Cm (In Case Where Bricks Are To Laid Over Cables) After Laying Of Cables And Then Complete Back Filling & Ramming Of Loose Soil As Per The Technical Specifications Ts-11. Description:- Back Filling And Consolidating Of Cable Trench First For 5 Cm (In Case Where Bricks Are To Laid Over Cables) After Laying Of Cables And Then Complete Back Filling & Ramming Of Loose Soil As Per The Technical Specifications Ts-11. , Description:- Supply Of Galvanized Trunking With Cover Of Same Material As Per Drg No. Rdso/Tcdo/Cop-12 Or Latest And Fixing On Girder Bridges Including Supply Of Channel Angle Iron Bracket Unit, Nuts And Bolts Of Proper Sizes And Filling Of Support At An Interval Of One Meter Including Laying Of Cable Inside The Trough And Filling With Bitumen Compound As Per Ts-12. Description:- Supply Of Galvanized Trunking With Cover Of Same Material As Per Drg No. Rdso/Tcdo/Cop-12 Or Latest And Fixing On Girder Bridges Including Supply Of Channel Angle Iron Bracket Unit, Nuts And Bolts Of Proper Sizes And Filling Of Support At An Interval Of One Meter Including Laying Of Cable Inside The Trough And Filling With Bitumen Compound As Per Ts-12. , Description:- Taking The All Types Of Cables Inside Station Relay Rooms/Abs Huts, Location Boxes And Junction Boxes Etc. And Sealing Of Cable Entry Pit Etc. As Per Technical Specifications, Complete With Contractors Material As Per Ts-13. Description:- Taking The All Types Of Cables Inside Station Relay Rooms/Abs Huts, Location Boxes And Junction Boxes Etc. And Sealing Of Cable Entry Pit Etc. As Per Technical Specifications, Complete With Contractors Material As Per Ts-13. , Description:- Supply , Transportation At Site& Erection Of Concreting Base Reinforced Cement Concrete Cable Route Marker As Per Technical Specification As Per Ts-14. Description:- Supply , Transportation At Site& Erection Of Concreting Base Reinforced Cement Concrete Cable Route Marker As Per Technical Specification As Per Ts-14. , Description:- Loading And Transportation Of S&T Cable From The Stores And Unloading At The Site Of Laying As Per Ts-18. Description:- Loading And Transportation Of S&T Cable From The Stores And Unloading At The Site Of Laying As Per Ts-18. , Description:- Supply, Transportation And Installation Of Reinforced Cement Concrete Joint Chamber With Two Piece Top Cover And Bottom Cover With Holes For Drainage And Cable Entry, As Per Ts. This Includes Trenching For Jointing Pit, Back Filling And Ramming Of The Pit After Placing The Joint Closure And Cable Loop In The Chamber Without Causing Any Damage To The Same And Consolidation Of Soil As Well As Disposal Of Excess Oil As Per Ts-20. Description:- Supply, Transportation And Installation Of Reinforced Cement Concrete Joint Chamber With Two Piece Top Cover And Bottom Cover With Holes For Drainage And Cable Entry, As Per Ts. This Includes Trenching For Jointing Pit, Back Filling And Ramming Of The Pit After Placing The Joint Closure And Cable Loop In The Chamber Without Causing Any Damage To The Same And Consolidation Of Soil As Well As Disposal Of Excess Oil As Per Ts-20. , Description:- Transportation To Site And Installation Of Electronic Cable Route Marker For Route, Track And Road Crossing Marking Along The Route Of Cable Laying As Per Ts-22. Description:- Transportation To Site And Installation Of Electronic Cable Route Marker For Route, Track And Road Crossing Marking Along The Route Of Cable Laying As Per Ts-22. , Description:- Programming And Geo Tagging By Taking Latitude & Longitude Of Rfid Markers By Using Integrated Locator In New Cable Laying & Existing Cable Laying Route With Digital Mapping Thru Mobile Application. Provision Of Hard Copy Of Digital Route Plan And Geotagging Data With Railway Track To Cable Distance On Digital Mapping As Per Ts-23 Description:- Programming And Geo Tagging By Taking Latitude & Longitude Of Rfid Markers By Using Integrated Locator In New Cable Laying & Existing Cable Laying Route With Digital Mapping Thru Mobile Application. Provision Of Hard Copy Of Digital Route Plan And Geotagging Data With Railway Track To Cable Distance On Digital Mapping As Per Ts-23 , Description:- Development Of A Mobile App For Division Of Nf Railway And Setting Up Of Local Server At Divisional/Zonal Hq For Tracking Of Cable Route Marker As Per Ts-24. Description:- Development Of A Mobile App For Division Of Nf Railway And Setting Up Of Local Server At Divisional/Zonal Hq For Tracking Of Cable Route Marker As Per Ts-24. Total 179028400.707 One Hundred Seventy Nine Million Twenty Eight Thousand Four Hundred And Seventy One Paise Quoted Rate Select 0.0 29 179028400.707 One Hundred Seventy Nine Million Twenty Eight Thousand Four Hundred And Seventy One Paise
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
West Bengal View Result →
22.
Public Administrative Department #11300283 AOC
Tender For CMLRRP-CMLRRP 2.0 - 2024 -25 , KUNDARA LAC , Sl .No . 3404 : Edakkara Parappumattel Road , Kundara GP , Kollam District -Ward 10-General Civil Work-- 1 RETARRING 2 75.5.5.B.2pb:Modified Penetration Macadam 75 mm thick using Bitumen S-65 - Packed Bitumen RatesConstruction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. 3 75.5.2.1pb:Tack Coat - With Packed Bitumen RatesProviding and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. 4 75.5.9.1.2pb:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 - Packed Bitumen Rates Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.Case - I By Manual Means(II) Bitumen (S-65) 5 75.5.12.A.3.2pb:Seal Coat - Manual Means - Type C - Bitumen S-65 - Packed Bitumen RatesProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510A. By Manual MeansCase III : Type C(II) Bitumen (S-65) 6 3.2:Preparation of Foundation for EmbankmentScarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical MeansScarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. 7 75.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4) 8 OD181210/2025-2026:Providing and fixing of direction and place identification retro-reflectorised sign with 7 years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with area not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on GI pipe pole 50mm NB-2 nos confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 40 cm x 40 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. (Derived from MoRD spec 10.3.A.2)
Contract Date: Jun 17, 2026 Contract Value : 14.57 Lakh
Government Departments No of Bidders 2
23.
Public Administrative Department #11300262 AOC
Tender For Annual Plan-ANICKAD GP- Wiring of ICDS Office-General Electrical Work - Wiring 2 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point 3 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point 4 90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point 5 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DBs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points 6 OD456938/2024-2025:Supply and fixing angle /straight-lined skirt type brass batten/ angle holder with 200 mm plastic shade with 7/9W LED Bulband giving connection as required 7 OD456944/2024-2025:Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover with 9 W LED to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor fle x wire conforming to relevant ISS or extending the original wiring and making good the surface as required.(Mepro /Philips/Crompton/Bajaj make) 8 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture 9 90.3.22.3:Supply & installation of light fittings on flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories andlamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture 10 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 11 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 12 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 13 OD456940/2024-2025:Supply Conveyance, installation, testing, and commissioning of 150mm medium duty 2300 rpm 4leaf, exhaust fan in the plastic body (Almonard/ Crompton make) in the existing opening. fixing necessary bolt and nuts, making good the damages, etc. as required including giving connections with required length of 24/20mm 3core round copper conductor flexible chord etc as required 14 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. 15 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 16 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 17 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 18 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm 19 1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm 20 1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm 21 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm 22 1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm 23 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm 24 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm 25 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm 26 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 27 1.53.2:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable 28 1.53.3:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable 29 OD457140/2024-2025:Supply and laying 1.5 m CAT-6 Patch Cord. Preferred make:-D link or equivalent 30 OD457141/2024-2025:Supply and installation of 16/24 Port 10/100 /1000 Mbps rack mountable switch Make: tp -link TL-SG 1016 D—7200 31 OD457142/2024-2025:Supply and fixing 2 module moulded plastic box/metal box on surface/recess, fixing moduler face plate with RJ 45 CAT 6 jack(Legrand/AMP/MK) 32 OD457143/2024-2025:Testing of each and every node point and making permanent labeling at the I/O box and on the patch panel. 33 OD457144/2024-2025:Supply and fixing of 19, 6U, 500 MM Depth Wall Mount Rack with Front Glass door, cooling fan 90cm ,NVRS, 1 No Power Distribution Unit Rack mounting type - 1 no, Cable Organizer /1U/Loop - 1No.(Netrack or equilent make) 34 OD457145/2024-2025:Supply and installation of CAT-6 24 Port Enhanced Modular type Patch Panel for interconnecting servers and clients including termination charges. Preferred Model:- D-Link or equivalent 35 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 36 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 37 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) 38 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 39 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 40 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 41 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 42 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door 43 90.11.1.10:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 44 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 45 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 46 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 47 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 48 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 49 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 50 90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) 51 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 52 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 53 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) 54 OD456945/2024-2025:Supply and providing 12x3 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 55 OD456943/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 56 OD457126/2024-2025:Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availing 3 phase service connection/Load regularization
Contract Date: Jun 16, 2026 Contract Value : 1.63 Lakh
Government Departments No of Bidders 2
24.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
25.
Defence #11299279 Price Bid
Tender for Demolition Of Brick Work, Stone/Boulder Masonry Built In Cement Mortar Complete All As Specified And Directed. , Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Any Type Of Soil Complete All As Specified And Directed. , Taking Down Cement Plaster On Brick Or Stone Surfaces Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc., Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:3:6 Type C2, Using 40Mm Graded Stone Aggregate, As In Foundation Filing, And Mass Concrete , Etc Complete All As Specified And Directed. , M&L Brickwork With Subclass ‘B Bricks Old Size, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:4 Cm Complete All As Specified And Directed. , All As Per Item No 5 But Except Brick Complete All As Specified And Directed. , M & L For Rendering 15Mm Thick In Cement Mortar 1:4 On Stone Masonry Surfaces Or Surface Other Than Fair Face Of Brick-Work Or On One Side Of Lathing, Finished Even And Smooth W/O Using Extra Cement Complete All As Specified And As Directed. , M & L For Rendering 15Mm Thick In Cement Mortar 1:4 On Surface On Fair Face Of Brick-Work ,Finished Even And Smooth W/O Using Extra Cement Complete All As Specified And As Directed. , M & L For Formwork To Flat Fair Finished Square, Rectangular Surface For Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter Finished Fair Complete All As Specified And Directed , M&L Reinforced Cement Concrete M-25 Using 20 Mm Graded Stone Aggregate As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And Directed , M & L For Formwork For Flat Fair Finished Square, Rectangular Surfaces To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And Directed. , M&L For Reinforced Cement Concrete M-25 Using 20 Mm Graded Stone Aggr As Columns, Pillars, Piers, Posts And Struts Complete All As Specified And Directed , M & L For Formwork Flat Fair Finished Square, Rectangular Surfaces To Sides And Soffits Of Floor Or Roof Beam, Beam Hauchings, Bands, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Complete All As Specified And Directed , M&L Reinforced Cement Concrete M-25 Using 20 Mm Graded Stone Aggr As In Beams, Bands, Cantilvers, Bressummers, Linters, Chajjas, Etc Over 1.5M Span Etc Complete All As Specified And Directed , M & L High Strength Steel Deformed Tmt Bars 10 Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping Columns,Hookings Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.90 Mm Dia Or Securing With Clips, Etc Complete All As Specified And Directed. , M&L For Mild Steel Bars (Tmt Bars) 5Mm Dia And Over Upto And Including 10Mm Dia In Strriups,Spacers And Binders Complete All As Specified And Directed. , M & L For Providing, Cement Concrete Type B-0 1:2:4 (12.5Mm Graded Aggregate) In Copings In Security Wall With Broken Glass Complete All As Specified And Directed , M & L For Mild Steel Framed Work Such As Grills, Gratings Etc With Ends Of Bars Shouldered And/Or Riveted, Or Forged Into Spikes, Framed Guard Bars, Barred Iron Doors, Ladders Framed Balusters, Walk Ways, Railings, Frame Work Of Water Tanks And Similar Work Conforming To E-165 (Fe-290) Complete All As Specified And Directed. , M&L For Preparation Of New Steel Surfaces Exc 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. , Material And Labour For Apply Two Coats Of 100% Premium Anti Fungal Weather Coat Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistence As Per Is 15489;2004, Alkali & Fungal Resistence, Dirt Resistence Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.9 Litre / 10 Sqm Over New Surfaces Complete All As Specified And Directed. Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Clain On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , Material And Labour For Complete Removal Of Existing Treatment And Apply Two Coats Of 100% Premium Anti Fungal Weather Coat Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistence As Per Is 15489;2004, Alkali & Fungal Resistence, Dirt Resistence Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.9 Litre / 10 Sqm On Old Surfaces Complete All As Specified And Directed. Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Clain On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , S&F In Repair Galvanised. 2 Strand, Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacings And Straining And Fixing To Any Type Of Standard Rails Strain- Ing Bolts, Including, Securing Or Tying At Crossings With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins, Etc. As Directed (Each Line Wire To Be Measured) Complete All As Specified And Directed. , M&L For Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600Mm Dia 10 Metre Openable Length (Total Length 90 Mtr), Having 50 Nos Rounds Per 6 Metre Length, Spring Core Wire (2.5 Mm Thick) Of High Tensile Strength Of 165 Kg/Sqmm With Tape (0.52Mm Thick) And Weight 43.478 Gm/ Metre And Fixing The Same With Existing Y-Shaped Angle Iron Placed 2M Apart And With 6 Horizontal R.B.T (Reinforced Barbed Tape) Wire, Stud Tied With G.I Staple And Gi Clips To Retain Horizontal, Including Necessary Bolts Complete All As Per Direction Of Engineer-In-Charge. Note:- Make Of Concertina Coil Shall Be Approved By Ge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
Jammu And Kashmir View Result →
26.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
27.
Public Administrative Department #11286668 AOC
Tender For Construction/Repair Work In Record Room/Nazarat Department - (a) Bricks M-150 2 (b) Bricks M-100 3 (c) Bricks-Straight over brunt 4 (d) Bricks- Tiles (Ist Class) 5 (e) Brick Bats M-75 6 (f) Brick Bats (O.B.) 7 Fly ash Bricks (specification/strength should not be less then Bricks M-150)size 230x110x75mm 8 Fly ash Bricks Tiles (specification/strength should not be less then Bricks M-150)size 230x110x38mm 9 Fly ash Concrete curve Stone (specification/strength should as per mord/morth) size 300x300x150mm (M30) 10 (a) 5.00cm. Gauge 11 (b) 4.00 cm. gauge 12 (c) 2.50 cm. gauge 13 Stone Grading Materials Aggregate - For 37.5 mm Maximum size - 22.4 mm to 5.6 mm 14 Aggregate - For 37.5 mm Maximum size - 45 mm to 22.5mm 15 Aggregate - For 37.5 mm Maximum size - Below 5.6 mm 16 Aggregate - For 53 mm Maximum size - 22.5 mm to 5.6mm 17 Aggregate - Grading I (40 mm nominal Size) 10 mm - 5 / 4.75 mm 18 Aggregate - Grading I (40 mm nominal Size) 25 mm – 10mm 19 Aggregate - Grading I (40 mm nominal Size) 37.25 mm -25mm 20 Aggregate-Grading I 90 mm to 45 mm 21 Aggregate-Grading II 63 mm to 45 mm 22 Aggregate-Grading III 53 mm to 22.4 mm 23 Aggregates 22.4 mm to 2.36 mm for wet mix macadam 24 Aggregates 45 mm to 22.4 mm for wet mix macadam 25 Crushed Sand or Grit Passing 2.36 mm and retained on 180 micron 26 Crushed Stone Aggregate 26.5 mm to 75 micron 27 Crushed Stone chipping 13.2 mm nominal size 28 Crushed Stone Chipping 6.7 mm size 100% passing 11.2 mm and retained on 2.36 mm 29 Crushed Stone Chipping 6.7 mm size 100% passing 9.5 mm and retained on 2.36 mm 30 Crushed Stone chipping 9.5 mm nominal size 31 Crushed Stone Coarse Aggregate Passing 53 mm and retained on 2.8 mm 32 Fine aggregate/Crushed sand 2.36 mm to 75 micron 33 Stone Boulder of size 150 mm and below 34 Stone for Coarse Rubble Masonry 1st Sort 35 Stone for Coarse Rubble Masonry 2nd Sort 36 Stone for Random Rubble Masonry 37 Stone for Stone Set Pavement (300 mm x 200 mm x 150MM 38 Well Graded Material for Sub-Base - Grading I 2.36 mm below 39 Well Graded Material for Sub-Base - Grading I 53 mm to 9.5 mm 40 Well Graded Material for Sub-Base - Grading I 9.5 mm to 2.36 mm 41 Well Graded Material for Sub-Base - Grading II 2.36 mm below 42 Well Graded Material for Sub-Base - Grading II 26.5 mm to 9.5 mm 43 Well Graded Material for Sub-Base - Grading II 9.5 mm to 2.36 mm 44 Well Graded Material for Sub-Base - Grading III 2.36 mm below 45 Well Graded Material for Sub-Base - Grading III 4.75 mm to 2.36 mm 46 Well Graded Material for Sub-Base - Grading III 9.5 mm to 4.75 mm 47 Boulder with minimum size of 300 mm for Pitching at Site 48 Granular Material or hard murrum for GSB works at Site 49 Close graded Granular sub-base Material 37.5 mm to 9.5 mm 50 Close graded Granular sub-base Material 9.5 mm to 4.75 mm 51 Close graded Granular sub-base Material 4.75mm to 75 micron mm 52 Close graded Granular sub-base Material 2.36 mm 53 Coarse graded Granular sub-base Material 4.75mm to 75 micron mm 54 Coarse graded Granular sub-base Material 4.75 mm to 2.36 mm 55 Coarse graded Granular sub-base Material 9.5 mm to 4.75 mm 56 Coarse graded Granular sub-base Material 26.5 mm to 4.75 mm 57 Coarse graded Granular sub-base Material 26.5 mm to 9.5 mm 58 Coarse graded Granular sub-base Material 37.5 mm to 9.5 mm 59 Coarse graded Granular sub-base Material 53 mm to 26.5mm 60 Stone screening material for WBM Grading-2 and 3 61 Miscellaneous Items Cement Grey PPC 62 Cement Port land (ordinary) 63 Cement white viz J.K./Birla 64 Wall Putty J.k / Birla white 65 Plaster of Parish Sakarni or eqvivalent 66 Cinder 67 Distemper oil bound 68 Dry Distemper ordinary of bes quality (Approved manufacture and approved quality viz. Burger, Asian, J&N 69 Glass Ordinary cut to size (a) 3mm thick (Wt. 7.5 Kg./sqmt.) 70 (b) 4mm thick (Wt. 10.0 Kg/sqmt.) 71 (c) 5.5 mm thick (Wt. 13.5 Kg/sqmt.) 72 White lime (unslacked) for White Washing 73 White Lead (Best Quality PIG Lead) 74 (d) G.I. Barbed wire 75 (e) Iron Sheet Galvanized Plain 22 gauge 76 (f) Iron Sheet Galvanized Plain 24 gauge 77 (g) -do- but corrugated 24 gauge 78 (h) -do- but black plain 18 gauge 79 (J) Expanded metal 2-0 cm mesh 16/17 guage 80 (K) M.S. binding wire 24 gauge 81 (i) 1x2 size of 10 gauge wire 82 (ii) 1x3 size of 10 gauge wire 83 (iii) Murga Jali 1/2x24 gauge 84 (iv) 1x2 size of 10 gauge wire 85 (i) F -d sections @ 1.58 Kg/R/M 86 (ii) F -B/T/T Secs. @ 2.40 Kg/R/M 87 (iii) F - Sections @ 0.74 Kg/R/M 88 (a) Super white 89 (b) Commercial white, coloured & black 90 Marble Dust (200 mesh) 91 Nails (Country) 92 Nails (Wire) 93 (a) Oil (linseed double boiled) 94 (b) Oil (Terpentine) 95 (a) Paint anticorosive Bitumenous 96 (b) Black Japan 97 (c) Superior Ready Mixed paints (Grade II) in 20 ltrs. Drums of approved manufactures and aporoved make 98 (i) Dark Green Oxide 99 (ii) Deep Black Oxide 100 (iii) Blue Oxide 101 (iv) Chocoiate Oxide 102 (e) (i) Red Oxide primer surface for steel (in 20 ltrs. Drum) (Approved manufactures and approved make) 103 (ii) Red lead paint ready mixed for roof (in 20 ltrs. Drum) (Approved manufactures and approved make) 104 (f)(i)PaintenamelGradeIsuperClass(Approved manufactures and approved make) 105 (ii) Paint (Aluminium) 106 (g) (i) Paint primer for wood 107 (ii) Paint primer for metal 108 (h) (i) Cement Primer of Berger or equivalent 109 (ii) Water proof cement paint (in 50 kg. drums) 110 (i) Clear synthetic (in 20 ltr drums) 111 (ii) Copall 112 (iii) Weather Coat cement paint for exterior 113 (iii) Weather Coat cement paint for exterior 114 Water Proofing compound (Dr. Fixit) 115 Polish (mansion & wax) 116 (iv) P.V.C. Pipe 110 mm dia & 6Kg./CM2 (ISI Marked) 117 (v) Same as above but 90 mm dia 118 (vi) Same as above but 75 mm dia 119 (v) Same as above but 140 mm dia 120 (a) Corrugated 121 (b) Plain 122 (i) Internal dia 5 cm (Wt. 11.41 Kg.) 123 (ii) Internal dia 7.5 cm. (Wt. 16.52 Kg.) 124 (iii) Internal dia 10 cm. (Wt. 21.67 Kg.) 125 (iii) Internal dia 15cm. (Wt. 21.67 Kg.) 126 (i) 5.0 cm dia (Wt. 2.30 Kg. ) 127 (ii)7.5 cm dia (Wt. 3.30 Kg.) 128 (iii) 10.0 cm. dia (Wt. 4.60 Kg.) 129 (i) 5.0 cm dia (Wt. 2.10 Kg. ) 130 (ii) 8.0 cm dia (Wt. 3.20 Kg.) 131 (iii) 10.0 cm. dia (Wt. 4.40 Kg.) 132 (c) C.I. Spout 23.0 cm Long 40 mm dia 133 (a) Rope (Moonj) 134 (b) Rope (HEMP) 135 (c) Rope (cotton) 136 (d) Spun yarn 137 Rivets 138 Coarse sand of approved quarry (Finess modules 2.20) at site of work in the district Saharanpur, Muzaffarnagar 139 Finesand(blendedtofineness modulus1.25) Saharanpur, Muzaffarnagar and Shamli 140 (a) Local Sand 141 Surkhi 142 White lime (slacked) 143 (a) Washers (Lumpet) 144 (b) Washers (Bitumen) 145 (c) Washers G.I. 146 J.Hooks 147 Wood presevator in 5 ltrs. Pack. 148 (a) Teak wood 149 (b) Sheesham 150 (c) Indian Sal 151 (a) Teak wood 152 (b) Sheesham 153 (c) Indian Sal/ maleshien 154 Fuel Wood (Dry) 155 (a) 2.2 cm width 156 (b) 3.50 cm. width 157 (c) Same as 48 (a) but 5 mm thick 158 (d) Same as 48 (b) but 5 mm thick 159 Antitermite treatment oil concentrate to 0.30 (as per IS 1307) 160 (i) 40mm thick 161 (ii) 50 mm thick 162 (a) KOTASTONE (machine cut ) 60 x 60 cm. 163 (a) Marble White 60 x 60 cm. 164 (b) Marble White 60 x 60 cm. 165 Granite stone black or Grey Polished 166 Granite stone black or Grey Polished 167 Polythene Sheet (125 Micron) 168 Plastic waste which is cleaned is cut into a size between 2.36mm and 600 microns and of maximum size 2.36 mm length and 2.00mm width. 169 (a) For Floor Size 300 x 300 170 (b) For Wall Size 200 x 300 171 (c) Vitrified Tiles size 600 x 600 172 RCC Hume Pipe 350mm dia 173 RCC Hume Pipe 450mm dia 174 (a) Ordinary 175 (b) For floor and tile work 176 Carpenter 177 Black Smith 178 Hammer man 179 Fitter 180 Painter 181 (a) Plumber Licensed with Kit or Koshal vikash CERTIFICATE 182 (a) Plumber Licensed with Kit or Koshal vikash CERTIFICATE 183 (b) Electrician Licensed with Kit or Koshal vikash certificate 184 (b) Electrician Licensed with Kit or Koshal vikash certificate 185 Mate 186 Beldar / Mali 187 Bhishti with Mushk 188 White Washer 189 Belder for bitumen or tar work 190 Glazier 191 Bhainsa Buggi with driver 192 Tractor trolley with driver excluding P.O.L. 193 Amin/Tracer 194 Chaukidar 195 Jeep/Truck/Tractor/Roller Driver 196 Generator Operator 197 Mixol Operator 198 Pump Operator 199 Cleaner 200 Sweeper (Full Time) 201 Sweeper (Part Time) 202 Tractor with harrow or water TankerTrolly with 203 Tractor with harrow or water TankerTrolly with 204 driver and P.O.L. 205 J.C.B. Machine with driver with P.O.L. 206 Crane (20-50 Tonnee) with Driver and P.O.L. 207 Ricksaw Thela with Driver 208 (a) Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M. and lead upto 30 M. and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in charge upto a distance of 30 M. from the foundation trenches. (where machine can not move ) 209 (a) As in item 251 (a) above but excavation in soil mixed with Moorum, shingle, kankar requiring the use of special tools and plant such as pickaxes, sabbals etc. (where machine can not move ) 210 (a) Earth work in cutting or in embankment in ordinary soil excavation to be in the form of regular pits not exceeding 0.50 M. in depth and earth work in embankment to be in 20 cm. layers including remming and dressing the surface to required levels and slopes and also including 1.50 M. lift and 30 M. lead. The earth from cutting to be used in making embankment or to be deposited as spoil banks with-in 30 M. distance as directed by the Engineer incharge. (Royality removed by Govt. ) for small works/ Abadi area. (where machine can not move ) 211 (a)Add to items (251-253) for every additional 30 M. (100 ft.) lead or part of 30 M (100 ft.) or for every additional 1.50 M. (5 ft.) lift or part of 1.50 M. (5 ft.) 212 (a) Sand filling in plinth and under floor including supply of necessary quantity of sand from a distance not exceeding 8 Kms. from the site of work and including watering, dressing etc. labour and T&P etc. required for proper complition of the work. saplings of girth upto 30 cms. measuredat a height of 1 M. above ground level and removal of rubbish upto a distance of 50 M. out side the periphery of area cleared. including cost of sand. 213 (i) Cleaning jungle including up rooting ofrank, vegetations grass, push, wood trees and amplings of grith upto 30 cms. measured at a height of 1 M. aboveground level and removal of rubbish up to a distance of 50M. out side the periphery of area cleared. 214 (a) Same as above 259(i) above but grass only. 215 (a) Add to item no. 253 (a) for mechanically compected to achieve 95% proctors density including arrangement of water, settlement and all T&P including roller and its fuel etc. 216 (b) As in item no. 260 (a) above but for departmental works excluding Roller charges and its fuel, cost of water, allT&P. and sundries etc. but including carriage of water to site. 217 Upto ½ Km 218 Ist Km. (If lead is beyond ½ Km.) 219 Concrete with 4 cm. guage brick ballast, white lime and surkhi in foundation and under floors in the proportion of 100:16:32 including supply of all materials, labour Tools & plants etc. required for proper completion of the work. 220 Concrete with 4 cm. gauge brick ballast, Fine sand of 1.25 F.M. and cement, in proportion of 12:6:1 in foundations and under floors, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 221 As in item 273 above but in proportion 10:5:1 222 As in item 273 above but in proportion 8:4:1 223 (a) Same as above item no. 279 but with 2 cm. gauge stone grit instead of 4 cm. gauge 224 (b) Same as item no. 279 (a) but in proportion of 1:3:6 225 As in item 279 above but in proportions of 8:4:1stone Ballast, Coarse sand and cement. 226 Concrete with 4 cm. guage brick ballast, white lime and surkhi in foundation and under floors in the proportion of 100:16:32 including supply of all materials, labour Tools & plants etc. required for proper completion of the work. 227 Concrete with 4 cm. gauge brick ballast, Fine sand of 1.25 F.M. and cement, in proportion of 12:6:1 in foundations and under floors, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 228 As in item 273 above but in proportion 10:5:1 229 As in item 273 above but in proportion 8:4:1 230 (a) Same as above item no. 279 but with 2 cm. gauge stone grit instead of 4 cm. gauge 231 (b) Same as item no. 279 (a) but in proportion of 1:3:6 232 As in item 279 above but in proportions of 8:4:1stone Ballast, Coarse sand and cement. 233 Same as item no. 302 (B) above but in 1:6 (One cement & six fine sand of 1.25 F.M.) mortar. 234 Same as item no. 302 (B) but in 1:5 (One cement & five fine sand of 1.25 F.M.) mortar 235 Same as item no. 302 (B) but in 1:4 (One cement & four fine sand of 1.25 F.M.) mortar. 236 (a) Same as item no. 302 (B) but in 1:4 (One cement & four Corse sand) mortar. 237 Same as item no. 302 (B) but in 1:3 (One cement & three fine sand of 1.25 F.M.) mortar. 238 Same as item no. 302 (B) but in 1:3 (One cement & three coarse sand) mortar. 239 As in item 302 (B) to 307 above but in superstructure including necessary Cutting & moulding of bricks as required thickness of walls not to be less than 1½ brick. Add extra labour to above items. 240 As in item 309 above but for walls of one brick thick, add for extra labour 241 As in item 309 above but for walls of Half brick thick, add for extra labour to the rate of item no. 309. 242 Same as item no. 302 (B) above but in 1:6 (One cement & six fine sand of 1.25 F.M.) mortar. 243 Same as item no. 302 (B) but in 1:5 (One cement & five fine sand of 1.25 F.M.) mortar 244 Same as item no. 302 (B) but in 1:4 (One cement & four fine sand of 1.25 F.M.) mortar. 245 (a) Same as item no. 302 (B) but in 1:4 (One cement & four Corse sand) mortar. 246 Same as item no. 302 (B) but in 1:3 (One cement & three fine sand of 1.25 F.M.) mortar. 247 Same as item no. 302 (B) but in 1:3 (One cement & three coarse sand) mortar. 248 As in item 302 (B) to 307 above but in superstructure including necessary Cutting & moulding of bricks as required thickness of walls not to be less than 1½ brick. Add extra labour to above items. 249 As in item 309 above but for walls of one brick thick, add for extra labour 250 As in item 309 above but for walls of Half brick thick, add for extra labour to the rate of item no. 309. 251 Teak wood wrought framed and fixed including simple mouldings, straight work as in chaukhats including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 252 As in item No. 401 but for sheesham wood 253 As in item no. 401 but with Indian Sal wood 254 Supply & fixing of 4.5 Cm. thick teak wood part panelled and part glazed door and window shutter including supply & fixing of wooden cleats and stops and including fixing & adjustment of hinges, bolts, locks, handles spring and or other fittings but excluding their supply and including painting with two coats of black Japan on all iron fitting if necessary. Including fixing the glass panes with putty for bradglass and glass to be 4 mm. thick. Fitting with necessary screws to be supplied by the deptt. 255 Providing and fixing Glass panes with teak wood beading in doors and windows as desired by the Engineer incharge including cost of all materials, fittings, hinges, labour, T&P all etc. required for proper completion of the work. 256 As in item no. 409 above but fully panelled. 257 As in item no 409 above but fully glazed. 258 As in item no. 409 above but 3.8 cm. thick. 259 As in item no. 411 above but 3.8 cm. thick. 260 As in item no. 412 above but 3.8 cm. thick. 261 As in item no. 409 above but 3.8 cm. thick, Shisham wood. 262 As in item no. 411 above but 3.8 cm. thick, Shisham wood. 263 As in item no. 412 above but 3.8 cm. thick, Shisham wood. 264 Supply and fixing of 3.8 cm. (1½) thick Teak wood door and window shutters with panels of heavy Quality galvanized iron wire gauge 2.5 mm. or 2 mm. or 1.5 mm. (1/10 or 1/12 or 1/16 inch) mesh or any other size, with necessary beadings, including supply and fixing of wooden cleats stops and including fixing & adjustment of hinges, bolts, locks, handles spring and or other fittings but excluding their supply and including two coat of black Japan on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally. 265 As in item (450) above but in shisham wood. 266 Supply and fixing Galvanized Mosquitos proof heavy quality S.S.Wire gauge heavy quality over windows and including supply of teak wood batten 8 cm.x1.cm. (3x3/8)/flat iron 25 mm.x4mm. and including supply of necessary screws all materials, labour, Tools & plants etc. required for proper completion of the work. 267 As in item (455) above but with shisham wood battens. 268 As in item (455) above but with Indian Salwood battens. 269 As in item (455) above but with Deodar wood battens. 270 As in item no. 409 but Indian Commercial flush shutters 35 mm. thick (excluding cost of all fitting). 271 As in item no. 409 but Indian Commercial flush shutters 32 mm. thick (excluding cost of all fitting). 272 As above 471 but Double Leaf Add. extra. 273 Approximate cost of ISI marked oxidized iron fitting with screws for door & windows etc. (for estimating purpose only) 274 As above item no. 473 Aluminium Fittings ISI marked. 275 Supply and fixing of 3.8 cm. (1½) thick country wood door fully panelled shutters including supply and fixing of wooden cleats stops and including fixing & adjustment of hinges, bolts, locks, handles spring and or other fittings 276 Supply and fixing 2.5 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fitting and glass panes (Double Leaf) 277 As in item no. 9.26 above but for single leaf. 278 Providing and fixing 12 mm thick and 100 mm. wide Ply board of plywood pelmet with 19 mm. dia Al. rod and brackets including fixing with 25x3mm. M.S. flat 10 cm (4) long and plug etc. complete with painting, polishing or oiling as required. 279 Supply and fixing of 3.2 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Double Leaf) 280 As in item no. 9.29 above but for single leaf. 281 Supply and fixing of 2.5 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Single Leaf) 282 Suppy and fixing of Teak wood batton for fixing of mosquito net and fixing of glass & over chouket at window/door. Inculding cost of all matrial, labour & T&P etc. complete. 283 As per item above A but with shisham wood batton 284 Fixing of Jali / glass in doors/windows in small area upto 1.00 sqm (Labour only) 285 Fixing of Curtain rods (Labour only) 286 Fixing of Curtain palmets (Labour only) 287 50x20 mm 288 50x12 mm 289 With 2nd class teak wood beading 62X19 mm. 290 300x16 mm 291 250x16 mm 292 250x10 mm 293 200x10 mm 294 150x10 mm 295 Providing and fixing 12 mm thick and 100 mm. wide Ply board of plywood pelmet with 19 mm. dia Al. rod and brackets including fixing with 25x3mm. M.S. flat 10 cm (4) long and plug etc. complete with painting, polishing or oiling as required. 296 Supply and fixing of 3.2 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Double Leaf) 297 As in item no. 9.29 above but for single leaf. 298 Supply and fixing of 2.5 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Single Leaf) 299 Suppy and fixing of Teak wood batton for fixing of mosquito net and fixing of glass & over chouket at window/door. Inculding cost of all matrial, labour & T&P etc. complete. 300 As per item above A but with shisham wood batton 301 Fixing of Jali / glass in doors/windows in small area upto 1.00 sqm (Labour only) 302 Fixing of Curtain rods (Labour only) 303 Fixing of Curtain palmets (Labour only) 304 50x20 mm 305 50x12 mm 306 With 2nd class teak wood beading 62X19 mm. 307 300x16 mm 308 250x16 mm 309 250x10 mm 310 200x10 mm 311 150x10 mm 312 250x10 mm 313 200x10 mm 314 150x10 mm 315 100x10 mm 316 125 mm 317 100 mm 318 75 mm 319 Providing and fixing aluminium tee channels (heavy duty) with rollers, stop end in pelmets as curtain rod. 320 Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71 mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI C sections (39mm x 19mm x O.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric L corners .The panel shall be filled with 3mm thick high - pressure compact laminate asper manufacturers specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). 321 With decorative veneering on one side and commercial veering on other side. 322 With non decorative veneering on both sides. 323 M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work. 324 Same as in item 502 above but in M.S. Grills / Stair case railing / gates / trusher / racks etc. 325 Same as in items 502 above but steel Z Section window excluding Glass panes. (i) Fixed panels 326 Same as in items 502 above but steel Z Section window excluding Glass panes.(ii) Openable panels 327 Same as in item 502 above but in heavy sizes such as trusses, built up gates, record racks, roof work, Gates etc. including rivetting or welding where necessary. 328 Boring holes in mild steel or iron not exceeding 10mm (3/8) diameter and thickness of plate not exceeding 6mm (1/4) 329 As in item (509) above but holes exceeding 10mm (3/8) diameter but not exceeding 20mm and thickness exceeding 6mm but not exceeding 13mm (1/2) 330 Providing and fixing 100mm (4) diameter C.I. Down pipe BC or equivalent make complete with bends with eye hole, plain bend shoes and gratings etc., fixed to walls with suitable clamps as directed by the Engineer-in-charge (C.I. pipe of 1.80 Meter length shall be of 20-21 Kg.) 331 Mild steel or iron work in purlins and rafters including drilling holes and fixing in position and including supply of all steel and bolts and nuts, wastage, labour and tools and plant etc. required for proper completion of work (No material shall be issued by deptt.) 332 Providing barbed iron wire fencing including fixing it to post after stretching it including labour and T&P etc. required for proper completion of the work but excluding cost of posts & barbed wire. (labour rate only) 333 with frame of 40x40x6mm (1½x1½x¼) angle iron 3.15 mm (1/8) thick M.S. gus set plate at the junction and corners including supply and fixing of necessary fittings. Lock rail of 15 length of oxidised iron and including pintels hooks at the top and applying priming coat of red lead paint on all sides complete. 334 As per item no 517a but with steel strip inplace of angle iron. 335 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm (3/4x3/8x1/12) and braced with flat form diagonals 20x5mm (3/4x3/16) size with top and bottom rails or T-iron 40x40x6mm (1½x1½x1¼) with 38 mm dia steel pullys with bolts, nuts locking arrangement, stoppers handles complete including applying a priming coat of approved lead paint. 336 Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40x40x6mm (1½x1½x¼) angle iron 3.15mm (1/8) gusset plates at the junctions and corners, hooks at top 25mm (1) dia pulleys at bottom, 40x40x6mm (1½x1½x¼) angles and T iron guides at top and bottom respectively including locking arrangement with handles etc. Complete and applying one priming coat of approved lead paint (No material shall be issued by deptt.) 337 Supplying and fixing rollingSHUTTERS of approved make made 80x125mm (3x5) cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. 338 Providing and fixing 27.5cm long wire spring grade 2 for rolling shutters. 339 providing and fixing top cover for rolling shutters 2.50 meter wide. 340 Providing and fixing ball bearing for rolling shutters. 341 (a) Shutters above 11.2 m² (120sqft) but upto 16.8m² (180 sqft) area 342 (b) Shutters above 16.8m² (180 sqft) area 343 (i) Door chaukhat 344 (ii) window chaukhat 345 (iii) Ventilator chaukhat 346 (iv) Stair case Nosing 347 Fixing of Main Gate / Steel Sutter /Garrage Gate etc. 348 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: profile B 349 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: profile C 350 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: profile E 351 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer on M.S. tube 12 SWG 352 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting and same with necessary stainless steel nuts and bolts complete, including fixing the rialing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, botls, fastners etc.) 353 M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work. 354 Same as in item 502 above but in M.S. Grills / Stair case railing / gates / trusher / racks etc. 355 Same as in items 502 above but steel Z Section window excluding Glass panes. (i) Fixed panels 356 Same as in items 502 above but steel Z Section window excluding Glass panes. (ii) Openable panels 357 Same as in item 502 above but in heavy sizes such as trusses, built up gates, record racks, roof work, Gates etc. including rivetting or welding where necessary. 358 Boring holes in mild steel or iron not exceeding 10mm (3/8) diameter and thickness of plate not exceeding 6mm (1/4) 359 As in item (509) above but holes exceeding 10mm (3/8) diameter but not exceeding 20mm and thickness exceeding 6mm but not exceeding 13mm (1/2) 360 Providing and fixing 100mm (4) diameter C.I. Down pipe BC or equivalent make complete with bends with eye hole, plain bend shoes and gratings etc., fixed to walls with suitable clamps as directed by the Engineer-in-charge (C.I. pipe of 1.80 Meter length shall be of 20-21 Kg.) 361 Mild steel or iron work in purlins and rafters including drilling holes and fixing in position and including supply of all steel and bolts and nuts, wastage, labour and tools and plant etc. required for proper completion of work (No material shall be issued by deptt.) 362 Providing barbed iron wire fencing including fixing it to post after stretching it including labour and T&P etc. required for proper completion of the work but excluding cost of posts & barbed wire. (labour rate only) 363 Providing and fixing 1mm thich M.S. Sheet door with frame of 40x40x6mm (1½x1½x¼) angle iron 3.15 mm (1/8) thick M.S. gus set plate at the junction and corners including supply and fixing of necessary fittings. Lock rail of 15 length of oxidised iron and including pintels hooks at the top and applying priming coat of red lead paint on all sides complete. 364 As per item no 517a but with steel strip inplace of angle iron. 365 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm (3/4x3/8x1/12) and braced with flat form diagonals 20x5mm (3/4x3/16) size with top and bottom rails or T-iron 40x40x6mm (1½x1½x1¼) with 38 mm dia steel pullys with bolts, nuts locking arrangement, stoppers handles complete including applying a priming coat of approved lead paint. 366 Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40x40x6mm (1½x1½x¼) angle iron 3.15mm (1/8) gusset plates at the junctions and corners, hooks at top 25mm (1) dia pulleys at bottom, 40x40x6mm (1½x1½x¼) angles and T iron guides at top and bottom respectively including locking arrangement with handles etc. Complete and applying one priming coat of approved lead paint (No material shall be issued by deptt.) 367 Supplying and fixing rollingSHUTTERS of approved make made 80x125mm (3x5) cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. 368 Providing and fixing 27.5cm long wire spring grade 2 for rolling shutters. 369 providing and fixing top cover for rolling shutters 2.50 meter wide. 370 Providing and fixing ball bearing for rolling shutters. 371 (a) Shutters above 11.2 m² (120sqft) but upto 16.8m² (180 sqft) area 372 (b) Shutters above 16.8m² (180 sqft) area 373 (i) Door chaukhat 374 (ii) window chaukhat 375 (iii) Ventilator chaukhat 376 (iv) Stair case Nosing 377 Fixing of Main Gate / Steel Sutter /Garrage Gate etc. 378 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B 379 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C 380 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E 381 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer on M.S. tube 12 SWG 382 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting and same with necessary stainless steel nuts and bolts complete, including fixing the rialing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, botls, fastners etc.) 383 Struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 Fineness modulus. 384 Same as in item 574 above but Flush pointing Deduct from item 574. 385 Same as in item 574 above but in floors deduction from item 574 & 575. 386 Struck cement pointing with 1:2 cement and fine sand of 1.25 F.M. mortar with colouring including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 387 12 mmthick plaster with cement and fine sand of 1.25 fineness modules in 1:3 over brick work minimum thickness not to be less than 1cm. including supply of all materials, labour, tools & plants etc. required for proper completion of the work. 388 As in item (582) above but with cement and approved coarse sand mortar in 1:3. 389 As in item (582) above but with cement and fine sand of 1.25 fineness modules mortar in 1:4. 390 As per Item No. 584 but with 1:4 cement and Corse sand 391 As in item (582) above but with cement and fine sand of 1.25 fineness modules mortar in 1:6. 392 Add for extra labour to all item of plaster if done ceiling. 393 Add for extra labour and materials for plaster over rough face of one brick wall. 394 2 cm. thick cement plaster in dado or skirting in 1:2 consisting of one part of cement & two parts of approved coarse sand laid in panels finished with 3 mm floating coat of neat cement or cement mixed with marble dust in ratio 5:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 395 Same as above item but 1.20cm. thick instead of 2 cm thick. 396 Engraving lines in plaster of outer face wall vertically and horizontally to display the surface as stone facing as directed by the Engineer-incharge including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (add for extra labour to all items of plaster), 397 Marking drip coarse in sun shades or facie with 1:3 cement and fine sand mortar as per direction of Engineer-in-charge including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 398 20 mm thick rough cast exterior cement plaster on walls consisting 10 mm thick backing cast of 1:3 cement mortar (1 cement :3 coarse sand) and 10 mm thick finishing coat of 1:3 cement mortar (1cement :3 coarse aggregate of size 6mm to 12 mm ) including arises, chamfers and/or rounded angles not exceeding 80 mm. 399 2.5 cm (1) thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2 cm. (1) graded approved stone grit, laid in panels finished with 3 mm. (1/8) floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and including 8 cm (3) thick base concrete consisting of cement, fine sand of 1.25 fineness modulus and brick ballast 4 cm. (1½) gauge in the proportion of 1:4:8 and removing any overlapping mortar at the joints of the penals if any and giving them a uniform finish, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 400 (A) As in item no. 601 above but without base concrete. 401 (B) As in item no. 601 above but base concrete consisting of brick ballast and fine sand & cement in prop. 12:6:1 402 As in item (601) above but floor shall be 4 cm (1½) thick instead of 2.5 (1) thick and without base concrete. 403 Add in item (601) to (603) and (605) when floors are polished including supply of extra cement, chapra batti, Carborandum stone, all other materials, labour, Tools & plants etc. required for proper completion of the work. Marble dust shall be added in the floting coat in ratio of 5:1 (cement and marble dust) if necessary but no extra amount will be paid for it. This includes final finish with french mansion polish or any other approved polish. 404 M-150 Brick on edge floor laid dry joints sand filled including preparation of base to proper slope and its ramming including supply of all materials labour and Tools and Plants etc. required for proper completion of the work. 405 As in item (615) above but bricks laid flat. 406 Granolithic marble flooring 2.5 cm. (1) thick consisting of 2 cm. (3/4) thick layer of 1 part cement, 2 parts of approved coarse sand and 4 parts of 2 cm. (3/4) graded approved stone chips including 5 mm (¼) thick surface coat with ordinary cement, black and white or grey or mixed marble chips passing 3 mm. (1/8) but retained on 1.5 mm. (1/16) mesh screen in proportion of 1:2 as specified or directed by the Engineer-incharge and polished by hand or machine and finally finished with French Mansion Polish or any other approved polish and including 8 cm (3) 1:6:12, concrete base, including supply of all materials, labour, Tools and Plants etc. required for proper completion of the work 407 As in item (620) above but when white cement is used in top 5 mm (¼) layer. 408 As in item no. (620) above but when coloured floors are to be made. 409 Granolithic marble dado 2 cm. (¼) thick consisting of 15 mm. (9/16) thick layer of one part cement, 2 parts of approved coarse sand including 5 mm. (3/16) thick surface coat with ordinary cement black or white or grey or mixed marble chips passing 3 mm. (1/8) but retained on 15 mm. (9/16) mesh screen in proportion of 1:2 as specified or directed by the Engineer-in- charge and polished by hand or by machine and finally finished with French Mansion Polish or any other approved polish including supply of all materials, labour, Tools and Plants etc. required for proper completion of the work. 410 Same as item no. 625 above but 12 mm. thick dado. 411 As in item (625) above but when white cement is used in top 5 mm. (3/16) thick layer instead of ordinary cement. 412 As in item (625) above but when coloured dados are to be made. 413 Supply and fixing 6 mm. (¼) China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete, including supply of all materials, labour and Tools and Plants 414 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete (a) of 2.2 cm. depth 415 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete (b) of 3.5 cm. depth 416 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete (c) of 2.2 cm. depth and of 5 mm thickness 417 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete(d) of 3.5 cm. depth and of 5 mm thickness 418 Extra for making chequers of approved patterns on cement concrete, floor, steps landing etc. 419 Supply and fixing of Kota stone in floor ing 20 mm thick and joint filled with 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12 mm base coat (bedding) of 1:2 cement & coarse sand morter and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 420 As in item no. New item (1) above but 25 mm thick. 421 Supply and fixing 10 to 12 mm thick Kota stone tiles in skirting or dado laid with 1:2 cement and approved coarse sand morter finished with in its cement colour slurry, jointing and polished of approved quality complete, including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 422 Supply and fixing 6 to 8 mm thick ivory or light shades vitrefied tiles 600x600 mm size in flooring and skirting with 1:3 approved cement and coarse sand morter finished with in its cement colour slurry, jointing and polished of approved quality complete, including supply of all materials, labour, tools andplants etc. required for proper completion of the work. as per direction of Engineer - in- charge 423 Painting or varnishing work in small areas or new wood work with one coat (upto one square metre of ready mixed priming paint and one coat of approved superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used ISI marked. 424 As in item (641) above but for every coat after first coat. 425 As in item (642) above but for every coat on previously painted old wood or Iron work including its sand papering, rubbing and cleaning as required for proper completion of work. 426 Painting roofs or other iron work in large areas with one coat priming and one coat of approved (above one Sq. Metre) paint (British antesol or equivalent) including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used ISI marked 427 As in item (644) above but for every coat after the first coat. 428 As in item (645) above but for every coat over previously painted surface 429 Painting or varnishing with valsper or other approved high grade enamel or super par synthetic clean varnish complete one coat over previously painted surface including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used ISI marked 430 As in item (647) above but for every subsequent coat on previously treated surface . 431 Distempering (first coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also including the surface even with plaster of Paris or approved synthetic materials and sand papered smooth including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 432 As in item (649) above but for every coat after the first coat. 433 As in item (649) above but for every coat after the previous coat or subsequent coat. 434 One coat hot coaltar on new surface including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 435 As in item (652) above but for every coat after the first coat or on previously treated surface. 436 One coat surface or other approved preservative on new wood work, including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 437 As in item (654) above but for every coat or on previously treated surface. 438 Oiling wood work with double boiled linseed oil including supply of all materials labour, Tools & plant etc. required for proper completion of the work. 439 Removing paint or varnishing with paint remover or with caustic Soda, including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 440 Polishing with French Polish or wax polish (in proportion 2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5 varnish by weight) on new wood and wood based surface to give an even surface including cleaning the surface of all dirt, dust and sand prepared smooth and a coat of wood filter including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 441 As in item No. (658) above but on previously polished wood or wood based surface. 442 Finishing wall with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 443 Same in item no. (660) but for each coat of water proof cement paint after the first two coat to give an even shade 444 Finishing wall with one coat of water proof cement paint of approved quality on previously old treated surface with this paint to give an even shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 445 Same aas item 660 but for weather coat. 446 Sameaasitembut over previouslypainted surface weather coat. 447 Providing cement primer on old/new surfaces 448 Providing wall putty on New surface with approvel quality material of Berger/J.K./Birla or similar make 2 coats 449 Providing wall putty on old surface with approvel quality material of Berger/J.K./Birla or similar make 2 coats 450 White washing one coat including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 451 As in item 671 above but Two coats. 452 As in item 671 above but Three coats. 453 Colour washing one coat using approved. Colouring material buff, blue, gray or brown shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 454 As in item 674 above but two coats. 455 As in item (674) but using approved colouring material of pink, green or yellow shade. 456 As in item 676 above but two coats. 457 As in item (674) above but colour washing with copper or iron sulphate one coat. 458 As in item 678 above but Two coat. 459 Cement washing including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 460 One priming coat and one coat of dry distemper on new work including supply of all materials, labour, Tools & plant etc. reqired for proper completion of work. 461 As in item (681) but for each coat of distemper after the first coat 462 Dismantling sundries brick work including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 463 Dimantling brick work or stone work in lime or cement mortar and including stacking of materials as directed be the Engineer-in-charge within a distance of 60 meter (200 feet). 464 As in item (692) above but in mud mortar. 465 Dismantling reinforced cement concrete or reinforced brick work including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 466 Dismantling Jack arched or wooden beam and barga roofs including beam, roof concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 467 As in item (695) above but only roof concrete. 468 Dismantlingcementconcreteorbrickor granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 469 As in item (697) above but floor to be stone flagged or tiled floor. 470 Dismantling corrugated Iron roofs walls or partitions,includingpurlins,battensand vertical supports and including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 471 Dismantling of girders, trusses and other steel work including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 472 Dismantling doors or windows including chaukhats with hold fast and including stacking of materials as directed by the Engineer-in- charge within a distance of 60 metre (200 feet). 473 Dismantling doors or windows leaves including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 474 Dismantling doors or windows including chaukhats but excluding hold fast and including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 475 Dismantling existing plaster including disposal of refuse as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 476 Raking out joint of brick work in cement or lime morter to a depth 1 cm. (3/8) including disposal of refuse as directed by the Engineer-in- charge within a distance of 60 metre (200 feet). 477 Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge within a distance of 60 metre (200 feet). 478 Supply and fixing of 10cm. (4) internal dia A.C. down pipes Everest or charminar make complete with bends with door at top and plain at bottom and grantings and including supply of necessary M.S. clamp 2.5cm x 3mm. (1 x1/8) fixed to walls with cement motar (1:2) and including supply of 15 cm (6) long 6mm. (1/4) dia nail all materials, labour and T& P. etc. required for proper completion of the work and also including repair of plaster pointing etc. if damaged during fixing of the pipes. 479 As per item No. 730 above but for 10.0 cm. PVC down pipe.(kissan/suprime make) 480 As per item No. 730 above but for 7.5 cm. PVC down pipe. .(kissan/suprime make) 481 As per item No. 730 above but for 5.00 cm. PVC down pipe..(kissan/suprime make) 482 Providing and injecting chemical for preconstruction anttermite treatment and creating and chemical barrier under and around the column pits wall trenches basement excavation top surface in plinth filling junction of wall and floor, along the external per meter of binding expansion joints surrounding or pipes and conduit etc. complete (plinth area of the building at ground floor only shall be measured as per I.S. 6313 (part II 1981) Aldrine emulsifiable concentrate or any other approved material such as heptachlor of chlordane will be used. The rate of application of chemical emulsion shall be as follows :- 1.Treatment for massonary and foundation 5 liters per sqm. 2.Back fill in immediate contact with foundation 7.5 liters per sqm. 3.Treatment of surface of plinth filling 5 liters per sqm. 4.Treatment of soil along external perameter of Building 7.5 liters per sqm 5. Treatment of soil under external parameter 5 liters per sqm. 483 Providing & injecting chemical for post Constructional anti termite treatment with drilling holes at junction of floor with walls & pillars, the application of chemicals shall be as per relevant I.S. code and the rate of application of chemical shall also be as provided in the I.S. code, including quarterly inspection and providing required treatment for one year. As direction by the Engineer-in-charge. 484 Consolidation of Kankar by hand rammer including opening out stacks sorting kankar into three sizes, repairing patches in existing road suface with kanker making medhi to retain water and ramming and also including carriage of metal upto 30 meters (100 ft.) carriage of water 200 metre supply and maintenance of barriers and all tools and plants required for proper completion of work, kankar to be supplied to the contractor free at site. 485 (A) As in item No. 752 above but 12 cm. (loose) thick coat of stone ballast. 486 (B) As in item No. 755 (a) above but excluding roller charges. 487 (D) As in item No. 755 (a) above but upto 10 cm. (loose) thick coat. 488 (E) As item No. 755 (b) above but upto 10cm. (loose) thick coat. but excluding roller charges. 489 Water allowance to be allowed on item No. 751 to 756 including carriage & cost of water where water is not available at site. 490 Dag belling 15cm (6) deep in one line aligned with flags and jhandies as directed by Engineer- in-charge. 491 Painting white/coloured traffic lines 8-15 cm. wide in three coats with approved road making paint (spirit base) as directed by the Engineer- incharge, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 492 Painting on divider 1 priming and two coats of enamel paint including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 493 As per item above but every coat after Ist coat and on old surface 494 Brick soling with strainght over burnt bricks laid flat and dry with brick edging on both sides including preparation of subgrade to prescribed camber and including supply of bricks, filling joints with local earth of P.I. 5 to 7, spreading blinding coat 1 cm (3/8) depth of local earth over the entire surface and including supply of all materials, labour Tools & Plants etc. required for proper completion of the work. 495 As in item No. 762(a) above but with bricks laid on edge. 496 M-150 Brick on edge pavement on parties with bricks, laid dry joints filled with local sand including preparation of base to proper slope, and its ramming, spreading layer of 1 cm. (3/8) depth of local sand over the subgrade and including supply of all materials, labour Tools &plants etc. required for proper completion of the work. 497 Renewing patries 1.5 metere wide including dressing surface filling upto 8cm (3) depth and making namunas, at every 15 metre apart on either side of the road true to patri template with side slopes of 1:2 etc. trenches for taking the earth to be so dug that they form a continuous side drain at road boundary. 498 Brick lining on both side of the road of M-150 bricks 7 cm. wide. 11 cm. deep, laid with mud mortar including labour & supply of bricks finished to the required template and in proper alignment and also including dressing and ramming the excavated earth as directed by the Engineer-in-charge. 499 Cleaning the existing painted /primed surface and laying premix 2cm. (3/4) thick over a tack coat with graded approved grit and bitumin (labour only) including heating the paint and grit to the required temperature and mixing either in mixer/ hand drum or by manual including cartage of materials, maintenance of side parties and watering them during operation for proper completion of the work as directed by the Engineer-in-charge . including labour charges for tack coat. 500 As in item No. 781 above excluding T&P and sundries etc. for departmental works. 501 As in item No. 781 above but in Patches. 502 As in item No. 781(a) but in Patches. 503 Cleaning the premix surface and laying seal coat with approved 6mm (1/4) graded grit and bitumin (labour only) including heating the paint to the required temperature and mixing either in mixer, hand drum including cartage of materials, maintenance of side parties and watering them during operation for proper completion of the work as directed by the Engineer-in-charge including all T&P and sundries to be arranged by the contractor but exculding roller charges and fuel wood. 504 As in item No. 783 above but in Patches. 505 Providing and applying primer coat over prepared surface of granular base with slow setting bitumen emulsion with spray set including cleaning of W.B.M. surface spreaying primer @ 0.6 kg/sqm (excluding emulsion) all labour T & P etc. as per MORT&H Specification. (labour rate only) in patches 506 Brick soling with straight over brunt bricks laid flat and dry (labour only) including preparation of subgrade to prescribed camber, filling joints with local earth spreading a blinding coat 1 cm (3/8) depth of local earth over the entire surface and including labour T&P etc.required for proper completion of the work.. 507 As in item No. 785 above but with bricks laid on edge. 508 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(i) 350 mm dia 509 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE (ii) 600 mm dia 510 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(iii) 800 mm dia 511 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(iv) 900 mm dia 512 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(v) 1000 mm dia 513 Fixing of joints in hume pipe with juit and cement etc.including cost of all matrial labour and T&P etc. required for proper completion of the work, (i) 350 to 600 mm dia 514 Fixing of joints in hume pipe with juit and cement etc.including cost of all matrial labour and T&P etc. required for proper completion of the work(ii) 800 to 1000 mm dia 515 (a) Laying and Consolidation of stone ballast in soling. by hand rammer for Patches.(Labour rate only) including filling of pot holes including cartage of water within 200M distance and blinding etc. Complete. 516 (b) Laying and Consolidation of Brick ballast/ bats in soling. by hand rammer for Patches.(Labour rate only) including filling of pot holes including cartage of water within 200M distance and blinding etc. Complete. 517 Barricating with approved wooden ballies vertical 10cm. Dia and 2m long fixed in ground 45 cm Deep and 2m apart including 2 rows of horizontal ballies not less than 8cm Dia 45 cm apart centre to centre tied by narial rope including cartage of all material and also including hire charges of ballies complete as direction of Engineer In charge. For two days 518 As item above but for more than 02 days. 519 As per item above but with three rows of horizontal ballies. 520 Dismantling of old brick laid on edge kharanja including stacking of old bricks . 521 As per item above but bricks laid flat / C.C. Interlocking tiles 522 Providing & laying of hot applied thermoplastic compound 2.5 m.m. thick including reflectorising glass beads @ 250 gms./Sq.mt. area. Thickness of 2.5 mm. inclusive of surface applied glass beads as per I.R.C. 2.35. The finished surface must be level, uniform and free from steaks and holes.Supplying & laying of Empty cement bags 523 Supply of 60mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 35 MPa and 4.00 kg per nos including cost of all material labour T & P .(i. ) Grey (ii ) Color 524 Supply of 60mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 35 MPa and 4.00 kg per nos including cost of all material labour T & P .(i. ) Grey (ii ) Color 525 Supply of 80mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 40 MPa and weight 4.50 kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P (i. ) Grey (ii ) Color 526 Supply of 80mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 40 MPa and weight 4.50 kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P (i. ) Grey (ii ) Color 527 Supply of 100mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 50 MPa and weight 5kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P .(i. ) Grey (ii ) Color 528 Supply of 100mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 50 MPa and weight 5kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P .(i. ) Grey (ii ) Color 529 Providing and laying of interlocking concrete Block pavement having thickness 60 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) 530 Providing and laying of interlocking concrete Block pavement having thickness 80 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) 531 Providing and laying of interlocking concrete Block pavement having thickness 100 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) 532 Providing & supply gunny bags including cost of sand and stitching of bags and laying in position. 533 Laying of interlocking tiles (labour only) 534 Disposal or malba 535 primaxing carpet 20 mm 536 seal coat 537 earth work in filling 538 45-90 mm gauge stone ballast 539 53-22.4 mm gauge stone ballast 540 stone screening meterial 541 mild steel for rcc work 542 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. a) 15 mm dia. nominal outer dia Pipes 543 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Chargeb) 20 mm dia. nominal outer dia Pipes 544 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Chargec) 25 mm dia. nominal outer dia Pipes 545 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charged) 32 mm dia. nominal outer dia Pipes 546 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Chargee) 40 mm dia. nominal outer dia Pipes 547 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. a) 15 mm dia. nominal outer dia Pipes 548 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. b) 20 mm dia. nominal outer dia Pipes 549 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. c) 25 mm dia. nominal outer dia Pipes 550 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. d) 32 mm dia. nominal outer dia Pipes 551 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin- Charge. External work.. a) 15 mm dia. nominal outer dia Pipes 552 b) 20 mm dia. nominal outer dia Pipes 553 c) 25 mm dia. nominal outer dia Pipes 554 d) 32 mm dia. nominal outer dia Pipes 555 e) 40 mm dia. nominal outer dia Pipes 556 f) 50 mm dia. nominal outer dia Pipes 557 g) 62.50 mm dia. nominal outer dia Pipes 558 h) 75 mm dia. nominal outer dia Pipes 559 i) 100 mm dia. nominal outer dia Pipes 560 j) 150 mm dia. nominal outer dia Pipes 561 Providing and fixing brass stop cock ISI marked approved quality as per direction of Engineer-in- charge. a) 15 mm nominal bore 562 b) 20 mm nominal bore 563 Providing and fixing brass stop bib cock ISI marked approved quality as per direction of Engineer-in-charge. a) 15 mm nominal bore 564 b) 20 mm nominal bore 565 Providing and fixing ball valve (brass)ISI marked approved quality complete , High & low pressure with plastic floats complite as per direction of Engineer-in-charge.High or low pressure with plastic floats: a) 15 mm nominal bore 566 b) 20 mm nominal bore 567 c) 25 mm nominal bore 568 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 a) 15 mm nominal bore 569 Providing and fixing C.P. brass long nose bib cock of approved quality confirming to ISI standards and weighing not less than 810 gms. a) 15mm nominal bore. 570 Providing and fixing C.P. brass stop cock (concealed) of approved quality confirming to ISI standards IS 8931 a) 15mm nominal bore. 571 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality confirming to IS:8931 a) 15 mm nominal bore 572 Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI: 12701 marked(Sintex or equivalent) with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete as per direction of Engineer-in- charge. 573 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White glazed earthen ware(Indian Type)/Neycer W.C. Pan 580 mm Dia. 574 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 30x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern 575 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern 576 Single half stall urinal with 5 litre PVC. automatic flushing cistern 577 Range of two half stall urinals with 5 litre PVC. automatic flushing cistern 578 Range of three half stall urinals with 10 litre PVC. automatic flushing cistern 579 Range of four half stall urinals with 10 litre PVC. automatic flushing cistern 580 Single squatting plate with 5 litre P.V.C. automatic flushing cistern 581 Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern 582 Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern 583 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C. P. brass pillar taps 584 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 585 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 586 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap 587 White Vitreous China Angle back wash basin of size 600x480 mm with single 15 mm C.P. brass pillar tap 588 White Vitreous China Angle back wash basin of size 400x400 mm with single 15 mm C.P. brass pillar tap 589 White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 590 Providing and Fixing while vitreous china pedestal for wash basin completely at the back for the reception of pipes and fittings. 591 ProvidingandfixingStainlessSteelAISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 250 mm 592 510x1040 mm bowl depth 250 mm 593 510x1040 mm bowl depth 225 mm 594 510x1040 mm bowl depth 200 mm 595 470x420 mm bowl depth 178 mm 596 Long pattern W.C. pan size of 580 mm 597 Orissa pattern W.C. pan size 580x440 mm 598 Providing and fixing water vitreous china pedestal type (Eurepean type/wash down type) 599 Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer–in- charge 600 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS 7231, with all fittings and fixtures complete.10 litre capacity – white 601 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 10 litre (full flush) capacity-white 602 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVCwaste fittings complete. Semi rigid pipe 32 mm dia / 40 mm dia 603 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 604 Providing and fixing soil, waiste and vent pipes: 100 mm dia Sand cast iron S&S as per IS - 3989 605 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 606 Hubless centrifugally cast (wpun) iron pipes epoxy coated inside & outside IS 15905 75 mm dia meter 607 Sand cast iron S&S as per IS - 1729 608 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 609 Hubless centrifugally cast (wpun) iron pipes epoxy coated inside & outside IS 15905 610 Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand): 100 mm dia 611 75 mm dia 612 50 mm dia 613 White vitreous china dual purpose W.C. pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend ISI Mark Kajaria eqvilent Indian made Brand. 614 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting of flushing capacity 3 litre/6 litre (adjustable to 4 litre/ 8 litre), including seat cover and cistern fittings, nuts, bolts and gasket etc complete. ISI Mark Kajaria eqvilent Indian made Brand. 615 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70 kg as per standard design. 100x100 mm size P type 616 with common burnt clay (non modular) bricks of class-150 150x100 mm size p type 617 with common burnt clay (non modular) bricks of class-150 618 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 619 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg 620 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Square shape 450 mm internal dimensions 621 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 450 mm internal diameter 622 Square shape 450 mm internal dimension 623 Circular shape 500 mm internal diameter 624 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg 625 Providing and fixing toilet paper holder standrad size ISI marked C.P. brass as per direction Engineer-in-charge 626 Painting letters upto 2.5 cm. size including supply of all materials, labour & tools and plants etc. required for proper completion of the work. 627 As in item 817 above but size above 2.5 cm. but upto 8 cm. 628 As in item no. 817 above 8 cm. but upto 15 cm. 629 Repairing letters upto 2.50 cm. size including supply of all meterials labour and tool and plants etc. required for proper comletion of the work 630 As in item NO. 820 above but size above 2.5 cm. but upto 8 cm. 631 As in item NO. 820 above but size above 8 cm. but upto 15 cm. 632 Painting Border line upto 2.5 cm. wide 633 Painting Border line upto 2.5 cm. to 5 cm. wide 634 Re-Painting Border line upto 2.5 cm. wide 635 Re-Painting Border line upto 2.5 cm. to 5 cm. wide 636 Repainting and relettering number plates on ends of parapets of culverts and bridges and boader line in letters height from 2.5 cm. to 8 cm. with approved enamael paint of superior quality including supply of all materials, labour and T & P etx. required for proper completion of the work. 637 Repainting and relettering of K.M. stones as per IRC design (except 5th km. Stone) with approved enemal paint of superior quality including supply of all materials, labour and T & P etc. required for proper completion of the work. 638 As in item 832 above but 5th km. stone 639 As in item 832 above but 200 H.M. stone 640 Varnishing /Painting on chair /side rack with stand and such other items including all matrial labour T&P etc. complite for proper completion of the work. 641 Varnishing /Painting on Double bed including all matrial labour T&P etc. complite for proper completion of the work. 642 Varnishing /Painting on Singal bed/ Sofa/ Dining table including all matrial labour T&P etc. complite for proper completion of the work. 643 Cutting and repairing of walls or windows for fitting of window type A.C. inculding wooden bidding after fixing. 644 White washing and hirmichi washing of culverts and trees upto a distance of 5 M. from the edge of black top in three bends of 1 width at a height of 1 M. from the crown of the road on either side of road. including supply of all materials, labour, T & P etc. required for proper completion of the work. 645 (a) Same as above but with departmental labour 646 Retro-Reflectorised Traffic Signs Direction and place identification signs up to 0.90 sqm Size BoardProviding and erecting direction and place identification retro- reflectiorised sign as per IRC-67 made of high intensity grade sheeting the retro- reflecive sheeting type -IV shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67- 2012 & proof of the same in form of Government report shall be uploaded while quoting tender vide MOR&TH clause 801.3 fixed over aluminium sheeting 2mm thick with area exceeding 0.9 sqm supported on a miled steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing complete. as per direction E- In- Charge Note : The Composite warranty jointly signed by original manufacturer & authorized converter of at least 7 years shall be furnished on non judicial stamp of required denomination both for retro reflective sheet and also complete signage. 647 Direction and place identification signsMore then 0.90 sqm Size Board Providing and erecting direction and place identification retro- reflectiorised sign as per IRC-67 made of high intensity grade sheeting the retro- reflecive sheeting type -IV shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67- 2012 & proof of the same in form of Government report shall be uploaded while quoting tender vide MOR&TH clause 801.3 fixed over aluminium sheeting 2mm thick with area exceeding 0.9 sqm supported on a miled steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing complete. as per direction E- In- Charge Note : The Composite warranty jointly signed by original manufacturer & authorized converter of at least 7 years shall be furnished on non judicial stamp of required denomination both for retro reflective sheet and also complete signage. 648 Retro Reflective Signs (Type-IV Sheet) for single side Providing and fixing retro-reflective signboards comprising of customised modular PU Epoxy Coated MS angle iron frame work, aluminum composite panel (ACP) as base board. micro prismatic retro-reflective sheet and electro cut colored overlay film/latex printing. The horizontal and vertical members including inclined outer members of the MS frame module shall be made of pair MS angle iron. No panel size shall be more than one sqm and each panel shall be braced diagonally (one way only) with MS angle. The MS frame module shall have length not more than 3 mtr. The aluminum composite panel (ACP) shall have a thickness of 4mm with 0.5 mm thick skin of aluminum on both sides. The ACP shall be fixed on the MS frame with pop riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP, micro prismatic retro-reflective sheet conforming to Type-IV of ASTM. D 4956-09 shall be pressure fixed. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67 2012 & proof of the same in form of government report shall be uploaded with quoting tender. The rate include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm 649 Retro Reflective Signs (Type-IV Sheet) for both side Providing and fixing retro-reflective signboards comprising of customised modular PU Epoxy Coated MS angle iron frame work, aluminum composite panel (ACP) as base board. micro prismatic retro-reflective sheet and electro cut colored overlay film/latex printing. The horizontal and vertical members including inclined outer members of the MS frame module shall be made of pair MS angle iron. No panel size shall be more than one sqm and each panel shall be braced diagonally (one way only) with MS angle. The MS frame module shall have length not more than 3 mtr. The aluminum composite panel (ACP) shall have a thickness of 4mm with 0.5 mm thick skin of aluminum on both sides. The ACP shall be fixed on the MS frame with pop riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP, micro prismatic retro-reflective sheet conforming to Type-IV of ASTM: D 4956-09 shall be pressure fixed. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67: 2012 & proof of the same in form of government report shall be uploaded with quoting tender. The rate include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm 650 Retro Reflective Signs (Type-IV Sheet) for both side ACP shall be fixed on the MS frame with pop riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP, micro prismatic retro-reflective sheet conforming to Type-IV of ASTM: D 4956-09 shall be pressure fixed. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67: 2012 & proof of the same in form of government report shall be uploaded with quoting tender. The rate include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm 651 Retro-reflectorised Traffic sign as per IRC 67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67:2012 made of high intensity grade sheeting vide clause 801.3, fried over aluminum sheeting type-IV 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67: 2012 & proof of the same in form of government report shall be uploaded with quoting tender. a) 90 cm equilateral triangle with diffinitation plate size (20 cm x 60 cm) 652 b) 60cm equilateral triangle with diffinitation plate size (20cm x 60cm) 653 c) 60 cm Circular with diffinitation plate (20 cm x 60 cm) 654 d) 80mm x 60mm rectangular with diffinitation plate (20cm x 50cm) 655 e) 60mm x 60mm rectangular with diffinitation plate (20cm x 50cm) 656 f) 60 cm x 60 cm square with diffinitation plate ( 20 cm x 60 cm) 657 g) 90 cm high octagon 658 h) 50 x 60 cm single chevron 659 i) 155 x 60 cm Double chevron 660 j) 30 x 90 cm (Left/Right) Object Hazard 661 k) 45 x 90 cm two way Object Hazard 662 l) 30 x 90 cm +45 x 78 cm Guarded/unguarded Railway crossing 663 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 .The finished surface to be level, uniform and free from streaks and holes. Rates are inclusive of all taxes, royalty, etc. all T&P/machine material and labour required for proper completion of work. 664 Supply, fixing and hoisting of 6.00-7.00 m. spanCantilever Structure in position with one vertical post of 6.00 M. clear height from the top of R.C.C. foundation made of 300 mm. dia pipe welded with 10 mm thick MS plate at bottom supported with 10 mm thick MS plate stiffners & two nos. 8 mm thick MS plates at top welded with structure of 40 mm NB (M) pipe comprising of horizontal, vertical & bracing pipe of 32 mm NB (M) as per structural design requirements & approved drawing with vertical & lateral clearance given in clause 802.2 & 802.3 including one coat of primer and two coats of synthetic enamel paint on the whole structure & installed as per clause 802.7 over a designed support system made up of concrete including excavation, lean concrete 1:4:8 cement, coarse sand and approved 20 mm grit and R.C.C. 1:2:4 with cement, coarse sand and approved 20 mm grit complete for fixing the complete structure in position as per direction of E/I charge. With 7 years warranty. Rates include design, fabrication, supply, transportation and erection of the signage structure inclusive of all taxes, royalty, etc. all T&P/machine material and labour required for proper completion of the work. 665 Supply, fixing and hoisting of 12.00 - 15.00 M span Overhead Structure in position with two vertical posts of 6.00 M. clear height from the top of R.C.C. foundation made of 300 mm. dia pipe welded with 10 mm thick MS plate at bottom supported with 10 mm thick MS plate stiffeners & two nos.10 mm thick MS plates at top welded with structure of 50 mm NB (M) pipe comprising of horizontal, vertical pipe of 40 mm NB (M) and bracing pipe of 32 mm NB (M) as per structural design requirements and approved drawing with vertical and lateral clearance given in clause 802.2 and design, fabrication, supply, transportation and erection of the sign board and also inclusive of all taxes, oyalty, etc all T&P/machine material and labour required for proper completion of the work. 666 Reflective Raised Pavement Marker Providing and fixing of raised 667 Reflective Raised Pavement Marker with shanks Providing and 668 Supplying & fixing of Linear Delineator System (LDS)panels made of Micro prismatic Retro Reflective sheeting Type XI duly laminated on thin aluminium foil to a unique corrugated shape to provide retro reflection across wide range of observations and external angles. Each LDS panel should be of nominal length of 33 inch and each ridge shall be approximately 0.34 inch high. Each LDS panel is to be firmly fixed on existing Concrite / brick work with 16 Nos Fastner/ screw as per IRC 79-2019 -Rates are inclusive of all taxes, royalty,etc. all T&P/machine material and labour required for proper completion of work. 669 Providing & fixing of Bollard made (Single side) out of aluminium sheet 4mm thick welded poly shaped to make it monolithic pillar size 1200mm high Bollard is having a frame 900x600mm and 600mm dia for fixation made out of 35x35x5mm angle iron and from side is fully coverd fixing the complete structure in position as per direction of E/I. charge. With 7 years warranty. Rates include design, fabrication, supply, transportation and erection of the sign board and also inclusive of all taxes, oyalty,etc all T&P/machine material and labour required for proper completion of work. 670 Supply & fixing of Bollard (Double side) Made out of aluminium sheet 4mm thick welded poly shaped to make it monolithic pillar size 1200mm high Bollard is having a frame 900x600mm and 600mm dia for fixation made out of 35x35x5mm angle iron and from side is fully coverd. fixing the complete structure in position as per direction of E/I. charge. With 7 years warranty. Rates include design, fabrication, supply, transportation and erection of the sign board and also inclusive of all taxes, oyalty, etc all T&P/machine material and labour required for proper completion of work. 671 Metal Beam Crash Barrier 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 672 Metal Beam Crash Barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2.0 m high, 1.5 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete 673 TREE PLATE S/F Reflective tree plate having Size 15 Cm x15Cm, Consisting type XI sheeting over 1.5mm thick aluminium sheet including labour. Material T&P etc for proper completion of the work. 674 Cartage of Ballast, Kankar, Coal, Grit or Sand etc. including loading and unloading but excluding stackings on pucca roads. I st Km. 675 2 nd Km. 676 3 th Km. 677 4 th Km. 678 5 th Km. 679 6 th Km. 680 7 th Km. 681 8 th Km. 682 9 th Km. 683 10 th Km. 684 11 th Km. 685 12 th Km. 686 13 th Km. 687 14 th Km. 688 15 th Km. 689 16 th Km. 690 17 th Km. 691 18 th Km. 692 19 th Km. 693 20 th Km. 694 21 th Km. 695 22 th Km. 696 23 th Km. 697 24 th Km. 698 25 th Km. 699 26 th Km. 700 27 th Km. 701 28 th Km. 702 29 th Km. 703 30 th Km. 704 31st to 75 Km. 705 76st to 100 Km. 706 100st to 200 Km. 707 As in item (231) above but for cement, steel or other materials : Ist Km. 708 2nd and 3rd Km. 709 4th and 5th Km. 710 6th to 10th Km. 711 11th to 20th Km. 712 21st to 30th Km. 713 31st to 50th Km. 714 51 to 75 Km. 715 76th to 100 Km. 716 101st to 200 Km. 717 201st to 250 Km. 718 As in item (231) above but for tar, bitumen Asphalt, Mobile oil or other such materials 1st Km. 719 2nd and 3rd Km. 720 4th and 5th Km. 721 6th to 10th Km. 722 11th to 20th Km. 723 21st to 30th Km. 724 31st to 50th Km. 725 51st to 75 Km. 726 76th to 100 Km. 727 101st to 200 Km. 728 201st to 250 Km. 729 Cartage of brick/stone ballast, kankar coal shingle or sand etc. by head load upto 90 metres (3 chains) including loading and unloading but excluding stacking 730 Loading and unloading of materials like ballast, shingle, kankar, coal or grit etc. excluding their stacking. (a) Loading 731 Loading and unloading of materials like ballast, shingle, kankar, coal or grit etc. excluding their stacking. (b) Unloading 732 Unloading of cement, tar or bitumen drum lighter steel sections and other such materials from wagons and stacking the same on platform. 733 As in item No. 236 (a) above but for heavy articles like joist etc. machinery and unwieldly structures 734 Stacking of bricks on edge in row of two to a height of ten brick and in a length of 100 bricks after dressing levelling of the site as required where bricks are to be stacked. 735 Stacking of coal, surkhi, sand, lime, stone grit, stone/brick ballast & boulders etc. to the required sizes to stacks after necessary dressing of site where such materials are to be stacked. 736 237 (a) above but when the materials are either cement / steel. 737 Loading of cement, tar or bitumen drums, lighter sections of steel and other such materials into wagons. 738 As in item 238 (a) above but for heavy articles like joist, machinery and unwieldly structures. 739 Cartage of R.C.C. Hume pipe 30cm. to 46cm. dia and 1.8 meter to 2.5 metre in length (including collars for which nothing extra will be paid ) including loading and unloading. 1st Km. 740 2nd and 3rd k.m. 741 4th and 5th k.m. 742 6th to 10th k.m. 743 11th to 20 th k.m. 744 21st to 30 th k.m. 745 31st to 50 th k.m. 746 51st to onward k.m. 747 As in item No. 239 (c) above but for R.C.C. Hume pipe 50 to 95 cm. dia and 1.8 meter to 2.5 meter in length carriage to be done by truck or by thela. 1st Km. 748 2nd and 3rd k.m. 749 4th and 5th k.m. 750 6th to 10th k.m. 751 11th to 20 th k.m. 752 21st to 30 th k.m. 753 31st to 50 th k.m. 754 51st to onward k.m.
Contract Date: Jun 15, 2026 Contract Value : Ref. Document
Local Bodies No of Bidders 10
Uttar Pradesh View Result →
28.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
29.
Civil Aviation #11266540 AOC
Bids Are Invited For Supply, Installation, Testing And Commissioning Of High-Definition Cctv Camera System To Cover Dark Zones At Udaipur Airport.; 1 Supply, installation, testing & commissioning of celling/Wall mounted IP FIXED DOME CAMERA (5MP OR Better) with including all mounting/fixing accessories such as mounting brackets, Nut bolts etc Compete all as required as per site.Note:- Camera shall be installed on existing celling/ wall. 2 Supply, installation, testing & commissioning of IP based Pole mounted IP PTZ 5 MEGA PIXEL CAMERA (5MP or better). with including all mounting/fixing accessories such as mounting brackets, Nut bolts etc Compete all as required as per the site.Note:- Cameras shall be installed on Existing Pole. 3 SITC of following CCTV equipments suitable for the smooth functioning of 60 number of CCTV cameras(30 no of cameras present work and 30 no of upcoming cameras in future ) in 19 floor standing 42 U Equipment Rack(a) Camera server and Storage (Main & Standby) : Rack Mountable Camera Servers ( MAIN and Stand By ) complete with all accessories With Minimum 80 TB Usable storage including Supply of Licensed OS & Antivirus as per specifications.(MAF from OEM shall be provided) (b) Video analytic server ( MAIN and Stand By ) complete with all accessories including Supply of Licensed OS & Antivirus as per specifications.(MAF from OEM shall be provided) (c) Network Time Protocol (NTP) server : as per specifications.(MAF from OEM shall be provided)(d) 2 No of 24 Port Multi gig Network Core Switch,12x10G/Multi-Gig and 12xSFP+ Managed Switch with Single Mode 10G (Upto 10 Kms) SFP+ ( 1 no main & 1 no stand by ) : as per specifications. (e)KVM switch : 8 Port USB KVM Switch with integrated 17 LED monitor, Keyboard, Mouse.(f)24 port Patch panel for CAT-6 termination(g) Light Guide Interconnect Unit (LIU) : as per specifications.(h)Cable manager in suitable Quantity & size/capacity(i) Power supply points suitable for internal power requirements(j) Ventilation Fan of suitable number and size/capacity 4 Supply and Installation of Licensed VIDEO MANAGEMENT SOFTWARE ON MAIN AND FAILOVER ( Including Software for 03 Client Workstation)Supply and Installation of 30 Nos. Camera License complete with all accessoriesNote:- Configuration of cameras are included in the scope of item 5 Supply of VMS per channel license. 6 Supply of video analytic per channel License 7 SITC of WORKSTATION CLIENT PC With 32 INCH UHD IPS MONITOR and VMS application software including Supply of Licensed OS & Antivirus Software Computer 8 SITC of 9U Indoor Wall Mount/Poll Mount 19 Rack with following components:- 8x1G Ultra90 PoE++ 802.3bt 720W 2x1G and 2xSFP+ Managed Switch with Single Mode 10G (Upto 10 Kms) SFP+ :as per specification.24 port Patch panel for CAT-6 terminationLight Guide Interconnect Unit (LIU) : as per specifications. 1KVA Online UPS with 30 Minutes Battery Back-up : as per specifications. 9 Supply and Laying of 6 CORE SINGLE MODE ARMOURED OFC CABLE in existing surface / Raceway / Cable tray /pipe/ Over false ceiling as per site requirement complete all as required. 10 SITC of SM 3 Meters LC-LC, SM duplex Fiber Patch cord for making connection between LIU Panel to network switch 11 Supplying and drawing of CAT 6 STP LAN CABLE in the existing surface/raceway/ recessed steel/ PVC conduit as required 12 SITC of 1 Meter CAT6 Patch cord ( Factory Crimped) 13 SITC of 55IPS UHD CAMERA MONITOR complete with wall/ceiling/floor/Table mounting arrangement -The monitors shall be installed on the walls. 14 SITC of 2 X 06 KVA ONLINE UPS SET (IN REDUNDANT CONFIGURATION WITH SMF BATTERY BACKUP, Min. 30 minutes back up at full load capacity) 15 Supply and installation of 20 ft high, 4 inch dia GI Pole with MS Base plate for camera with mounting accessories in cement concrete foundation including material, excavation and refilling etc complete as required 16 Supply and laying of 3 core 2.5 Armoured sqmm multi-strand PVC insulated PVC sheathed copper conductor power cable in existing conduit/pipe on surface/recess/concealed including all accessories. 17 Supply of 80 mm dia GI pipe (Class B) with all accessories as per site conditions 18 Supplying and fixing of 25 mm dia size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 19 Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 20 Cutting / breaking PCC/Bituminous area including excavation and refilling of soft soil upto suitable depth and 400 mm width for laying of GI pipes and remaking the same as good as previous etc. complete as required.
Contract Date: Ref. Documents Contract Value : 80.87 Lakh
Boards / Undertakings / PSU No of Bidders 9
30.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
31.
Drinking Water Supply and Sanitation #11257813 AOC
Tender For pipe water supply To Paraja Limka Village:- Paraja Limka Gp Padampur Under Koraput Block Under Dmf(2023-24) Programme.- 1 CONSTRUCTION OF 50,000 LTR Capacity RCC OGR 2 Designing , construction, testing and commissioning of 50,000 ltr capacity circular shape flat bottom with domb shape RCC on the ground reservoir(OGR) including supplying , fitting, fixing of M.S and aluminuim ladder , water level indicator, lightening arrester 1 nos. 80 mm CI puddle collar-4, 2 nos. CI MH cover, Inlet & Outlet arrangement with 80 mm dia GI pipe - 18 mtr and soil testing & drawing design etc. testing of the joints all complete fitting and fixing 80 CI sluice valves-2 Nos, Sluice valve chamber -2 nos of standard make providing CC M-25 for RCC work with 20mm & down grade size hg chips with 20mm thick cement plater over the cement concrete work, cement punning over plaster surface and painting 2 coats of water proofing weather coat etc. all complete as per approved drawing and design as per direction of Engineer-in-Charge. 3 CONSTRUCTION OF PUMP HOUSE 4 Supplying all labour, T&P and materials for earth work excavation in foundation in all kinds of soil with all lead & lift including dressing the sides & levelling the bed of the foundation as directed by the Engineer-in-charges complete as per specification & direction of the Engineer-in-charge. 5 Supplying all labour, T&P and materials and providing Cement Concrete (1:4:8) in foundation and plinth with 4cm. H.G.Stone metal with cost, conveyance, royalty, taxes of all materials required for the work as per specification & direction of the Engineer-in-charge. 6 Supplying all labour, T&P and materials and providing R.R. H.G.Stone masonary with C.M.(1:6) in foundation and plinth with granite stone including cost, conveyance, labour, tax, royalty of materials to worksite complete as directed by the Engineer-in-charge. 7 Supplying, filling in foundation & plinth with sand in 15cms. (9) thick layers with the cost conveyance royalties, taxes of the materials complete as per specification and direction of the Engineer-in-charge 8 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips of approved quality and from approved quarry including hoisting lowering laying and compacting concrete watering and curing for four weeks, finishing the exposed surface smooth including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect .as per specification and direction of the Engineer-in-charge.(Plinth Bend) 9 Supplying all materials, labour, T&P and providing Brick work with C.B Bricks in c.m (1:6) in superstructure using well burnt C.B bricks of size 23cm x 11cm x 8cm including cost, conveyance, royalty of all materials as per specification and direction of the Engineer-in-charge. 10 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect but excluding cost of MS Rods or Tor Steel and binding wires of 18 to 20 gauge as per including the cost of required quantity of centering and shuttering as per the dirction of the Engineer in Charge. 11 Lintel 12 Chajja 13 Straightening bend up or coiled rods cutting bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor Steel and binding wires and binding, tying the grills, hoisting, lowering and placing in proper position as required for R.C.C. works including cost, conveyance and taxes of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc, complete in all floors as per specification and direction of the Engineer-in-charge. 14 Cost of M.S doors and windows : 15 Labour for fitting & fixing M.S. choukath to door & windows including making holes in the brick wall and fixing the clamps by using C.C (1:2:4) by using 12mm. size h.b.g chips with all cost, conveyance, labour, T&P etc., required for the work complete as per specification and direction of the Engineer-in-charge. 16 Supplying all materials, labour, T&P and providing 12mm (1/2) thick cement plaster (1:6) finished smooth with cost and conveyance of all materials as per specification and direction of the Engineer-in-charge. 17 Supplying all materials, labour, T&P and providing C.C. (1:2:4) work using 12mm size hard black broken granite stone chips including cost, conveyance, royalty & taxes etc, complete in all respect but excluding cost of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge as per specification and direction of the Engineer-in-charge. 18 Providing, fixing tiles in dados skirting and risers of steps on 12mm. thick cement plaster(1:3) jpinted with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 19 Providing & fixing (Glazed) tiles in all floor & treads of steps & landing on 25 mm thick bed of cement mortar in proportion (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 20 Supplying all materials, labour, T&P and providing 20mm (3/4) thick cement plaster (1:6) finished smooth to out side of stone work after raking out the joint including, watering and curing with cost and conveyance of all materials and labour with T&P ,all taxes and royalties etc., complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 21 Supplying all material, labour, T&P and providing grading concrete with C.C(1:2:2) using 06mm. Size hard stone broken chips of approved quality including hpisting and laying not exceeding 25mm. thick with proper packing and required slope, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect as per specification and direction of the Engineer-in-charge. 22 Supplying all labour, T&P and materials and finishing walls with two coats of weather coat over a coat of white wash with good shell lime with cost, conveyance, royalties and taxes of all the materials and labour with T&P required for the work etc, complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 23 Painting two coats with any approved paint to new wood work and iron work including sand papering, polishing the surface, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect including the the cost of appoved paint as per specification and direction of the Engineer-in-charge. 24 LAYING OF RISING MAIN 25 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 26 In all kind of Soil : (500.00mtr x 0.38mtr x 0.90mtr) 27 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 28 90 mm HDPE Pipe PE-80 PN-6 29 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 30 In all kinds of soil : 31 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 32 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 33 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 34 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 35 LAYING OF DISTRIBUTION SYSTEM 36 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 37 In all kind of Soil : (800 mtr x 0.38mtr x 0.90mtr) 38 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 39 63 mm HDPE Pipe PE-80 PN-6 40 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 41 In all kinds of soil : 42 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 43 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 44 100 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 45 80mm CI NR Valve IS- 14846/2000 PN-1.00 46 15 mm dia CISingle Air Valve IS 14845/2000 47 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 48 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 49 Air Valve Chamber(Size 0.75mtr x 0.75mtr x 1.15mtr) 50 Supplying all materials, labout T&P pipes, fittings, push/rotary type water tap for construction of RCC single mouth stand post of size 250x250 mm platform of 1050x1050 mm with 3000 mm waste water drain as per approved drawing design and specification with CC M20 unsing 12 mm size h.g.c.b chips of approved quality from approved quarry including hoisting, laying and compacting and finishing the exposed surface smooth watering and curing including earth work in excavation in hard soil and rigid smooth centring and shuttering for cement concrete works along with MS Rainforcement as per specification including cost, royalty and conveyance charges of all materials etc. complete directed by Engineer in Charge. 51 Transporting and supplying all materials, labour T&P, fabricating, fitting and fixing with specials at the site using Electric resistance welded pipes of reputed make (TATA / Zindal ), confirming to IS 1239 (P-1) 2004, IS 1978 & IS 3598, medium quality & standard weight, including cutting the pipes & flanges, drilling the bolt holes in the flanges, matching the pipes and flanges and jointing with proper gradient & alignment, welding with arc welding using electrodes with power generated by using mobile diesel generator set, etc. complete as per direction of Engineer in charge, including painting two coats with black anti-corrosive paint over one coat of primer, all cost, conveyance, taxes of paints, cost of fittings as T, Bend, Offsets, Nuts and bolts, Leather packing etc. but including the cost of flanges and required earthwork, cutting holes in masonry works etc. 52 80 mm dia G.I pipe 53 INTERNAL ELECTRIFICATION 54 Supplying the following materials ,required labour and T &P and providing internal electrification to pump house as required at site including commisioning and testing as per the direction of the Engineer in Charge. 55 Surface wiring to light point in 20mm dia PVC cond. Pipe on MS board wiyh 3mm thick mulltistand copper wire. 56 a. Short point 57 b. Medium point 58 Surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 59 surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 60 Medium point 61 B.H. Fitting including all connection. 62 63 AMP 440 V ICTPN main switch 63 3 nos 63 Amp kitkat fuse on MS Board. 64 32 Amp main switch with all connections 65 Sub- main wiring 4 x 4mm2 copper wire with in 20mm dia pvc conduit. 66 Sub- main wiring 2 x 2.5mm2 copper wire with in 20mm dia pvc conduit. 67 Standard earthing in 38mm dia 3mtr long GI pipe with No 8 GI wire including all connections. 68 4 x 40 W F.L. Fitting complete with tube. 69 25 x 5 mm thick iron FL frame , ( 6.5 ft x 2.5 ft ) embeded on wall with all consumable materials like cement chips painting etc including all connections with PVC paint, flexible pipe,copper cable etc. 70 15 Amp switch and socket on 10 x 12 size MS board with all connections 71 RYB phase indicator with control 5 Amp F.T. switch with all connection. 72 5 Amp plug point on separate board fixed with 7 x 4 MS box with lylem cover with necessary connection. 73 Short point 74 10mm2 4 core cable 75 Ceiling Fan 76 PUMPING UNIT 77 Supplying installing, testing & commissioning of suitable vertical Sumersible pumping set of any repurted make such as KSB/Crompton/Greaves/ Kirloskar CRI/Suguna etc with energy efficient motor with ISI mark to run in 3 phase AC supply capble to discharge clear water from Intake well @2.85 lps against a total head of 80 mtrs. along with suitable pannel board of reputed make with ISI mark and 3 core flat submersible cable of reputed make with ISI mark . 78 5.00 HP 79 Supplying Testing ,and installation of suitable control pannel Board for suitable vertical submerssible pump and motor set with reputed ISI make. 80 Make BCH/L & T/Havels 81 Supplying, fitting & testing of 6mm2 three core flat submerssible electric cable reputed ISI make Finolex/BCH/Havells 82 Supplying, fitting & testing of required assessories like G.I R/S, stainless Steel nipple, G.I bend,wire ropw all of heavy quality with M.S calmp, MS bore cover etc. as required at site to complete the installation of the pimp set etc. complete in all respect. 83 Supplying of 50 mm dia HDPE suction pipe for lowering of pump & motors etc Please Enable Macros to View BoQ information
Contract Date: Jun 09, 2026 Contract Value : 15.06 Lakh
Government Departments No of Bidders 9
32.
Public Administrative Department #11256857 Price Bid
Tender for Price Schedule /Boq Tender Inviting Authority :- Nagar Palika Parishad Laharpur, Sitapur Nature Of Work: Request For Proposal (Rfp) For Development & Implementation And Maintenance Of Gis-Enabled Property Survey With Revenue Mapping System Tender No.: 70Npplaharpur/Gis/Date 15-05-2026 Bidder Name Note- Evaluation For Bids Shall Be Done On Total Bid Price (Excluding Gst) Received For Each Schedule S. N. Description Of Work (Modules/Services) Unit Qty Basic Price (In Rs.) Gst % Total Price Without Gst (In Rs.) , Digital Door Numbering Solution (G.I.S.)With Door To Door Survey For All The Dwellings In The Jurisdiction Of Nagar Palika Parishad Based On A Geo-Spatial Solution, Depicting An Alpha Numeric Smart Address Code For Each Property/Establishment Under Boundaries Of Nagar Palika Parishad With The Information Of Main Road, Sub Road/Lane, Landmarks Building And The Floor. Npp Also Intends Benefits Of Providing Navigation Details And Address Location Services To The Dwellings/Properties Within The Jurisdiction Of Nagar Palika Parishad And Also Help See Spatial Depiction Of Information Related To Electricity, Water Connection, Property Tax And Fee Collection Management. (Per Property) 2 (A) Printing Of Ward Wise Color Maps At Appropriate Scale (A1 Size) Per Map 1.0 0.0 2 (B) Printing Of Ward Wise Color Maps At Appropriate Scale ( A0 Size) Per Map 1.0 0.0 , Printing Of Ward Wise Booklet , 17 Digit Unique Id Generation Of Per House , Whatsapp Chatbot Payment System , Sms Services For Citizen Information With Payment Link , Mobile Application For Citizen Payment System , Pos System With Tax Collection System Per Unit Note: Financial Evaluation For Selection Shall Be Carried Out On The Basis Of The Lowest Unit Rate Quoted (L1) For Each Line Item Separately, Excluding Gst And Other Applicable Charges, For The Gis Survey Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Uttar Pradesh View Result →
33.
Drinking Water Supply and Sanitation #11249728 AOC
Tender For pipe water supply To Kumar Limka Adivasi Sahi & Kumar Sahi Village:-Kumar Limka Adivasi Sahi Gp Padampur Under Koraput Block Under Dmf(2023-24) Programme- 1 CONSTRUCTION OF 50,000 LTR Capacity RCC OGR 2 Designing , construction, testing and commissioning of 50,000 ltr capacity circular shape flat bottom with domb shape RCC on the ground reservoir(OGR) including supplying , fitting, fixing of M.S and aluminuim ladder , water level indicator, lightening arrester 1 nos. 80 mm CI puddle collar-4, 2 nos. CI MH cover, Inlet & Outlet arrangement with 80 mm dia GI pipe - 18 mtr and soil testing & drawing design etc. testing of the joints all complete fitting and fixing 80 CI sluice valves-2 Nos, Sluice valve chamber -2 nos of standard make providing CC M-25 for RCC work with 20mm & down grade size hg chips with 20mm thick cement plater over the cement concrete work, cement punning over plaster surface and painting 2 coats of water proofing weather coat etc. all complete as per approved drawing and design as per direction of Engineer-in-Charge. 3 CONSTRUCTION OF PUMP HOUSE 4 Supplying all labour, T&P and materials for earth work excavation in foundation in all kinds of soil with all lead & lift including dressing the sides & levelling the bed of the foundation as directed by the Engineer-in-charges complete as per specification & direction of the Engineer-in-charge. 5 Supplying all labour, T&P and materials and providing Cement Concrete (1:4:8) in foundation and plinth with 4cm. H.G.Stone metal with cost, conveyance, royalty, taxes of all materials required for the work as per specification & direction of the Engineer-in-charge. 6 Supplying all labour, T&P and materials and providing R.R. H.G.Stone masonary with C.M.(1:6) in foundation and plinth with granite stone including cost, conveyance, labour, tax, royalty of materials to worksite complete as directed by the Engineer-in-charge. 7 Supplying, filling in foundation & plinth with sand in 15cms. (9) thick layers with the cost conveyance royalties, taxes of the materials complete as per specification and direction of the Engineer-in-charge 8 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips of approved quality and from approved quarry including hoisting lowering laying and compacting concrete watering and curing for four weeks, finishing the exposed surface smooth including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect .as per specification and direction of the Engineer-in-charge.(Plinth Bend) 9 Supplying all materials, labour, T&P and providing Brick work with C.B Bricks in c.m (1:6) in superstructure using well burnt C.B bricks of size 23cm x 11cm x 8cm including cost, conveyance, royalty of all materials as per specification and direction of the Engineer-in-charge. 10 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect but excluding cost of MS Rods or Tor Steel and binding wires of 18 to 20 gauge as per including the cost of required quantity of centering and shuttering as per the dirction of the Engineer in Charge. 11 Lintel 12 Chajja 13 Straightening bend up or coiled rods cutting bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor Steel and binding wires and binding, tying the grills, hoisting, lowering and placing in proper position as required for R.C.C. works including cost, conveyance and taxes of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc, complete in all floors as per specification and direction of the Engineer-in-charge. 14 Cost of M.S doors and windows : 15 Labour for fitting & fixing M.S. choukath to door & windows including making holes in the brick wall and fixing the clamps by using C.C (1:2:4) by using 12mm. size h.b.g chips with all cost, conveyance, labour, T&P etc., required for the work complete as per specification and direction of the Engineer-in-charge. 16 Supplying all materials, labour, T&P and providing 12mm (1/2) thick cement plaster (1:6) finished smooth with cost and conveyance of all materials as per specification and direction of the Engineer-in-charge. 17 Supplying all materials, labour, T&P and providing C.C. (1:2:4) work using 12mm size hard black broken granite stone chips including cost, conveyance, royalty & taxes etc, complete in all respect but excluding cost of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge as per specification and direction of the Engineer-in-charge. 18 Providing, fixing tiles in dados skirting and risers of steps on 12mm. thick cement plaster(1:3) jpinted with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 19 Providing & fixing (Glazed) tiles in all floor & treads of steps & landing on 25 mm thick bed of cement mortar in proportion (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 20 Supplying all materials, labour, T&P and providing 20mm (3/4) thick cement plaster (1:6) finished smooth to out side of stone work after raking out the joint including, watering and curing with cost and conveyance of all materials and labour with T&P ,all taxes and royalties etc., complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 21 Supplying all material, labour, T&P and providing grading concrete with C.C(1:2:2) using 06mm. Size hard stone broken chips of approved quality including hpisting and laying not exceeding 25mm. thick with proper packing and required slope, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect as per specification and direction of the Engineer-in-charge. 22 Supplying all labour, T&P and materials and finishing walls with two coats of weather coat over a coat of white wash with good shell lime with cost, conveyance, royalties and taxes of all the materials and labour with T&P required for the work etc, complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 23 Painting two coats with any approved paint to new wood work and iron work including sand papering, polishing the surface, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect including the the cost of appoved paint as per specification and direction of the Engineer-in-charge. 24 LAYING OF RISING MAIN 25 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 26 In all kind of Soil : (500.00mtr x 0.38mtr x 0.90mtr) 27 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 28 90 mm HDPE Pipe PE-80 PN-6 29 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 30 In all kinds of soil : 31 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 32 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 33 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 34 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 35 LAYING OF DISTRIBUTION SYSTEM 36 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 37 In all kind of Soil : (800 mtr x 0.38mtr x 0.90mtr) 38 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 39 63 mm HDPE Pipe PE-80 PN-6 40 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 41 In all kinds of soil : 42 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 43 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 44 100 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 45 80mm CI NR Valve IS- 14846/2000 PN-1.00 46 15 mm dia CISingle Air Valve IS 14845/2000 47 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 48 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 49 Air Valve Chamber(Size 0.75mtr x 0.75mtr x 1.15mtr) 50 Supplying all materials, labout T&P pipes, fittings, push/rotary type water tap for construction of RCC single mouth stand post of size 250x250 mm platform of 1050x1050 mm with 3000 mm waste water drain as per approved drawing design and specification with CC M20 unsing 12 mm size h.g.c.b chips of approved quality from approved quarry including hoisting, laying and compacting and finishing the exposed surface smooth watering and curing including earth work in excavation in hard soil and rigid smooth centring and shuttering for cement concrete works along with MS Rainforcement as per specification including cost, royalty and conveyance charges of all materials etc. complete directed by Engineer in Charge. 51 Transporting and supplying all materials, labour T&P, fabricating, fitting and fixing with specials at the site using Electric resistance welded pipes of reputed make (TATA / Zindal ), confirming to IS 1239 (P-1) 2004, IS 1978 & IS 3598, medium quality & standard weight, including cutting the pipes & flanges, drilling the bolt holes in the flanges, matching the pipes and flanges and jointing with proper gradient & alignment, welding with arc welding using electrodes with power generated by using mobile diesel generator set, etc. complete as per direction of Engineer in charge, including painting two coats with black anti-corrosive paint over one coat of primer, all cost, conveyance, taxes of paints, cost of fittings as T, Bend, Offsets, Nuts and bolts, Leather packing etc. but including the cost of flanges and required earthwork, cutting holes in masonry works etc. 52 80 mm dia G.I pipe 53 INTERNAL ELECTRIFICATION 54 Supplying the following materials ,required labour and T &P and providing internal electrification to pump house as required at site including commisioning and testing as per the direction of the Engineer in Charge. 55 Surface wiring to light point in 20mm dia PVC cond. Pipe on MS board wiyh 3mm thick mulltistand copper wire. 56 a. Short point 57 b. Medium point 58 Surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 59 surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 60 Medium point 61 B.H. Fitting including all connection. 62 63 AMP 440 V ICTPN main switch 63 3 nos 63 Amp kitkat fuse on MS Board. 64 32 Amp main switch with all connections 65 Sub- main wiring 4 x 4mm2 copper wire with in 20mm dia pvc conduit. 66 Sub- main wiring 2 x 2.5mm2 copper wire with in 20mm dia pvc conduit. 67 Standard earthing in 38mm dia 3mtr long GI pipe with No 8 GI wire including all connections. 68 4 x 40 W F.L. Fitting complete with tube. 69 25 x 5 mm thick iron FL frame , ( 6.5 ft x 2.5 ft ) embeded on wall with all consumable materials like cement chips painting etc including all connections with PVC paint, flexible pipe,copper cable etc. 70 15 Amp switch and socket on 10 x 12 size MS board with all connections 71 RYB phase indicator with control 5 Amp F.T. switch with all connection. 72 5 Amp plug point on separate board fixed with 7 x 4 MS box with lylem cover with necessary connection. 73 Short point 74 10mm2 4 core cable 75 Ceiling Fan 76 PUMPING UNIT 77 Supplying installing, testing & commissioning of suitable vertical Sumersible pumping set of any repurted make such as KSB/Crompton/Greaves/ Kirloskar CRI/Suguna etc with energy efficient motor with ISI mark to run in 3 phase AC supply capble to discharge clear water from Intake well @2.85 lps against a total head of 80 mtrs. along with suitable pannel board of reputed make with ISI mark and 3 core flat submersible cable of reputed make with ISI mark . 78 5.00 HP 79 Supplying Testing ,and installation of suitable control pannel Board for suitable vertical submerssible pump and motor set with reputed ISI make. 80 Make BCH/L & T/Havels 81 Supplying, fitting & testing of 6mm2 three core flat submerssible electric cable reputed ISI make Finolex/BCH/Havells 82 Supplying, fitting & testing of required assessories like G.I R/S, stainless Steel nipple, G.I bend,wire ropw all of heavy quality with M.S calmp, MS bore cover etc. as required at site to complete the installation of the pimp set etc. complete in all respect. 83 Supplying of 50 mm dia HDPE suction pipe for lowering of pump & motors etc Please Enable Macros to View BoQ information
Contract Date: Jun 09, 2026 Contract Value : 15.06 Lakh
Government Departments No of Bidders 9
34.
Defence #11244927 AOC
Bids Are invited for Anpr Camera Ip Poe Deployed And Spare Stock , Ptz Camera Ip Poe , Boom Barrier Automatic , Uhf Rfid Reader Long Range High Power , Uhf Rfid Windshield Tag Passive , Outdoor Led Text Display , Traffic Signal Light R Y G , Gi Pole 6M , Poe Managed Switch 8 Port , Poe Managed Switch 16 Port , Single Mode Sfp 1310Nm 10Km Gate End , Industrial Ups 4 Hour Backup Standard Gate Load , Industrial Ups 4 Hour Backup Higher Gate Load , Cat6 Outdoor Utp Cable 305M Box , Rj45 Cat6 Connectors Boots , Outdoor Junction Box Ip65 , Manual Override Pushbutton Console , Central Application Server Rack Tower , Network Video Recorder Nvr 32 Channel , Surveillance Hdd 8Tb , Core Managed Switch 24 Port Sfp , Single Mode Sfp 1310Nm 10Km Control Room Spare , Server Rack , Online Ups 4 Kva 2 Hour Backup , Patch Panel 24 Port Cat6 , Uhf Rfid Desktop Encoder Reader , Rugged Android Tablet 10 Inch , Rugged Tablet Case Screen Guard Strap , Cat6 Patch Cords 1M 3M Mix , Lc Lc Single Mode Patch Cords 3M , Fiber Termination Panel Ftp 12 Port , Fiber Optic Cable Single Loose Tube 6F , Hdpe Plb Duct 40 33Mm , Hdpe Duct Coupler , Hdpe Duct End Cap , Route Marker Warning Tape , Fiber Splicing Service Fusion , Fiber Termination Panel At Gate , Otdr Power Meter Testing , Civil Work , Electrical Wiring Per Gate , Earthing Pit Per Gate , Camera Pole Installation Per Gate , Boom Barrier Installation Foundation , Network Equipment Installation Commissioning , Camera Configuration Anpr Calibration , Custom Software Development Wages Infra , Edge Anpr Sdk , Gpu For Edge Server , Edge Server , Local Storage 1Tb , Wall Cabinet 4U Ip54 , Ups Upgrade Kit , Cabinet Fan Kit , Access Controller , Led Screen 55 Inch Real Time Viewing At Centre , Surge Protector Total Quantity : 15184
Contract Date: Ref. Documents Contract Value : 54.36 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
35.
Defence #11233985 Price Bid
Tender for Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , M&L For Rendering 15 Mm Thick On Fair Faces Of Brick Work In Cm 1:6 Finished Even And Fair Without Using Extra Cement Complete. , M&L For 15Mm Thick Cement Plaster In Cm (1:4) On Fair Faces Of Brick Or Concrete Surfaces Using Wpc Where Ever Required As Per Manufacturerers Instructions And Finishing The Surface Even And Fair Etc. Complete All As Specified Note -Wpc Shall Be Measured And Paid Separetely. , Supply Only Wpc Complete All As Specified And Directed. , M&L For Rendering 5 Mm Thick In Cm (1:3) On Fair Faces Of Brick Work Or Concrete Surfaces On Ceiling Surfaces And Finishing The Surface Even And Smooth Without Using Extra Cement All As Specified And As Directed. , M&L For Preparation Of New Plastered Surfaces Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete. , M&L For Preparation Of New Plastered Surfaces Of Walls And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer Complete. , M&L For Preparation Of New Plastered Surfaces Of Ceiling And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer Complete. , M&L For Preparation Of Old Plastered Surfaces Of Walls Incl Washing Rubbing Down And Stopping Of Distempered And Painted And Applying One Coat Of Oil Bound Distemper On Old Decorated Surfaces On Walls Incl Filling Of Nail Holes By Cementious Wall Care Putty All As Specified And As Directed. The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , All As Per Item No 9, But Applying Two Coats Of Oil Bound Distemper , M&L For Preparation, Complete Removal Of Old Treated Surfaces Of Ceiling And Applying One Coats Of Distember Oil Emulsion, White Or Tinted, Complete All As Specified And Directed. , M&L For Providing And Applying Minimum 2 Mm Thick Wall Care Putty Over Prepared Surface (Old And New Plastered Surface) And Rubbing It With Sand Paper To Achieve The Surface Even And Smooth For Further Application Of Finishes Complete All As Specified And Directed. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 10 Mtr Height Complete All As Specified And Directed) , M&L For Preparation Of Old Decorated Plastered Or Unplastered Surfaces Of Walls Incl Cornices Etc By Brooming Down Or Steel Wire Brushing Scraping Down Smoke Soot Moulds Moss And Efflorescent Salt And Trading Oil And Greasy Spots And Applying One Coat Of Cement Base Paint Complete All As Specified And Directed.The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , M&L For Preparation Of Old Decorated Plastered Or Unplastered Surfaces Of Walls Incl Cornices Etc By Brooming Down Or Steel Wire Brushing Scraping Down Smoke Soot Moulds Moss And Efflorescent Salt And Trading Oil And Greasy Spots And Applying Two Coat Of Cement Base Paint Complete All As Specified And Directed.The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , M&L For Preparation Of Old Or Previously Treated Steel Surfaces Of Any Description,Not Otherwise Descri- Bed Over 10Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paint Complete All As Specified And Directed. , M&L For Preparation Of Old Or Previously Treated Wooden Surfaces Of Any Description,Not Otherwise Described Over 10Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paint Complete All As Specified And Directed.. The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , M&L For Preparation Of Old Or Previously Treated Cemented Surfaces Of Any Description,Not Otherwise Descri- Bed Over 10Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paint Complete All As Specified And Directed. , M&L For One Coat Of Exterior Emulsion Paint On Old Treated Surface Of Wall Preparation Of Plastered Surface To Make Surface Truely Smooth Complete All As Specified And As Directed By Engr-In-Charge. The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , M&L For Two Coat Of Exterior Emulsion Paint Over A Priming Coat (As Per Manufactures Instruction) On Old Treated Surface Of Wall After Complete Removal Of Existing Treatment Including Preparation Of Plastered Surface And Provision Of 2Mm Thick Wall Putty In Two Layer To Make Surface Truely Smooth Complete All As Specified And As Directed By Engr-In-Charge. , M&L For Preparation Of Existing Old Treated Cgi/Pgi Sheet Roof Surface Of Any Description Not Otherwise Described Over 10 Cm Width Or Girth By Cleaning , Removing Dust And Incl Washing And Cleaning Etc To Receive Painting And Applying One Coats Of Roof Paints ( Coptic Of Jenson & Nicholsan Or Antisol Of Berger) Complete All As Spd And Directed The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. , M&L Glazed Coloured Ceramic Tiles In Verticle Surfaces 450 X 300 X 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match With Backcoat Of Screed Bed Or Bedding Layer 10Mm Thick 1:4 And Pointed In White Or Coloured Cement To Match Complete All As Specified. , M&L Non - Skid Coloured Ceramic Tiles 7 To 10 Mm Thick (Square/Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry Over Screed Bed Of 15 Mm Thick 1:6 And Pointed In White Or Coloured Cement To Match Complete. , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , S&F For 15Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , S&F For 20 Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Bib Tap Long Body Cp, Screwed For Iron Pipes Complete All As Specified And Directed , S&F In Repair Angle Cock 15 Mm Bore Brass Fancy Type Chromium Plated, Screwed Both Ends For Pipes Or For Unions Fixed In Repairs Including Making Good To Match With Existing Surface , S&F In Repair Pillar Taps 15 Mm Bore, Brass Chromium Plated , Screwed Down High Pressure With Or Without Letter Hot Or Cold With Long Screwed Shanks And Fly Nut Complete All As Specified, Fixed In Repairs. , S&F In Repair Bib Tap Standard Of Ptmt (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath Fitting), Any Colour, Screwed Foriron Pipe 15 Mm Bore Pipe (Minimum Weight 90 Gm) All As Specified, Fixed In Repairs , S&F In Repair Polymer White (Polypropeylene Delrin And Abs) Low Level Flushing Cistern 10 Ltrs Capacity, Valveless, Syphonic Action Type Complete With Inlet, Ball Valve Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete, Complete All As Specified And Directed. , S&F In Repairs, 550X400mm Vitreous China, Wash Hand Basin , Flat Back Excluding Trap And Waste Chain And Plug And Porcelain Stopper Including Sutaible Size Brackets Waste Pipe And Waste Coupling Complete All As Specified And Directed. , S&F In Repair Hot And Cold Single Hole Basin Mixer Brass Chromium Plated 15Mm Bore Fixed As In Repairs Complete All As Specified And Directed. , S&F In Repair Brass Cp Wall Mixer For Mixing Hot & Cold Water (3 In 1) Screwed Down For Iron Pipe And Fixed Bore Of Pipe 15Mm Complete All As Specified . , S&F 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 3 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F In Repairs Of Stainless Steel Wire Cloth. 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples Complete All As Specified And Directed. , S&F In Repair One Piece Floor Mounted Vitreous China Ewc With Integrated Flushing Cistern, Soft Closing Seat Cover And Necessary Nut/Bolt For Fixing Complete All As Specified And As Directed By Engr-In-Charge , S&F In Repair Tubular Towel Rail Cp Brass, Chromium Plated D Type With Cp Brackets, 600 Mm Long Between Flanges All As Specified. , S&F In Repair Soap Dish Cp Complete All As Specified And Directed , S&F Pvc Whb Waste Pipe 32/40 Mm Dia Compolete All As Specified , S&F In Repair Hand Shower (Health Faucet) Cp Brass 15 Mm Bore With 1 Meter Long Easy Flex Tube In Chrome Finish And Wall Hook With Nrv (Back Flow Preventer) As Approved By The Ge. , S&F In Repairs Chromium Plated Shower Rose 125 Mm Swivel Type , S & F In Repair 25Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fancy Type With Brackets Complete All As Specified. , S & F In Repair Pvc Connections 15Mm Dia , 600Mm Long, With Ptmt Nuts & Washers At Both Ends , S&F In Repair Glass Shelf 450 X 125 X 6Mm (With Abs Bracket Chromium Plated Bracket Guard And Ss Railing Complete All As Specified And As Directed , Dismantling Of Brick Tiles Or Terracing Tiles, Single Layer On Roofs Complete All As Specified. , M&L 50Mm Thick (Laid In Two Equal Layer Of 25 Mm Thick) In Plain Cement Concrete 1:2:4 Type B-0 (Using 12.5Mm Graded Crushed Stone Aggregate) Including Finishing Even And Fair As In Roof Padding And Prepare Surface To Receive Treatment Complete All As Specified And Directed. , S & F 1.4Mm Dia Galvanised Steel Wire Netting 20Mm X 20Mm Mesh Size , Made Up Into Matteresses Or Cages, Lapped , Wired And Laid In Position ,Incl Fixed With Tinned Tacks Of Wire Staples Complete All As Specified. , M&L 40 Mm Thick Brick Tiles Laid Over And Including 15Mm Thick Bedding Layer In Cement Mortar 1:6 And Jointed, Grouted And Pointed Flush In Cm 1:3 Mixed With Stp No-1 Liguid @ 200Ml Of Per 50 Kg Of Cement Complete All As Specified. , M&L For App Based Polymeric Membrane Minimum Weighing 3.00Kg/Sqm And Minimum 3Mm Thick Reinforced With Polyster Non Woven Fabric ( Wt Not Less Than 150 Gms /Sqm ) Laid On Bituminous Surfaces By Forced Application Over Entire Roof Area, With Side Lap Not Less 100Mm And End Lap Not Less Than 150Mm Complete All Specified. , M&L For Applying A Tack Coat Of Industrial Bitumen 85/25 Grade @ 1.2 Kg/Sqm Over A Coat Of Bitumen Primer @ 0.30 Kg/ Sqm Including Cleaning Surfaces Etc Complete All As Specified , S&F In Repair Rotational Moulded Polythene Water Storage Tanks Tripple Layer (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity With And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Complete All As Specified And Directed. , S&F In Repair Rotational Moulded Polythene Water Storage Tanks Tripple Layer (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity With And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Complete All As Specified And Directed. , S&F In Repair 110 Mm Bore Pvc Rain Water Drain, Waste And Vent Pipes Single Socketed Ncluding Necessary Fittings Like Socket, Bend, Elbow, Single/Double Tee Etc In Any Length With Rubber Ring Joints Fixed With Clamps Of Flat Iron And Including Bolts And Nuts And Securing Ends Of Stays To Wall Or Roof And Making Good With Cement Mortor 1:3 Or With Plain Cement Concrete 1:2:4 Complete All As Directed. , Demolition Of Brick Work Built In Cement Mortar All As Specified , M&L For Brick Work With Sub Class B Bricks, Straight On Plan Exc 6M Mean Radius Built In Cm 1:6 Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
Uttarakhand View Result →
36.
Defence #11219952 AOC
Tender For (Schedule-A Part-I B/R Works) Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Not Exc 1.50 Sqm Each And Removing From Site Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Exc 1.50 Sqm Eachand N Exc 4 Sqm And Removing From Site Complete All As Specified And Directed. , Taking Down Shutter Of Any Description Area Exc. 1 Sqm And N.Exc. 2 Sqm And Removing From Site Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Including All Quions, Arches, Pillars Etc But Excluding Ashlar Facings Dressed Stone Work And Precast Concrete Articles Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Complete All As Specified And Directed. , Demolition Of Cement Concrete (Reinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Reinforcement Cut As Required To Facilitate Demoltion Complete All As Specified And Directed. , Taking Down Cement Plaster On Brick Or Stone Wall Etc Including Racking Out Joints, Hacking For Key Scrubbing Down With Water Etc To Receive New Plaster Etc. Complete All As Specified And Directed. , S&F Pressed Steel Frames Of Size 125 Mm X 60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc. Complete All As Specified And Directed. , S&F Pressed Steel Frames Of Size 105 Mm X 60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc Complete All As Specified And Directed. , S & F For 35 Mm Thick Factory Made, 2Nd Class Hard Wood Glazed And Skeleton Shutters Open Rebeated And Prepared To Received Glass, Gauzed, With Out Sash Bar Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitered Beads For Securing Glass Etc, Size Of Member Of Shutter As Per Specified In Ssr Part-I Section 8, Clause 8.24 (A) And For Door And Fixed With Chowkats, Chemically Pressure Treated Complete All As Specified And As Directed. , S&F For 35Mm Thick 2Nd Class Hard Wood Plain, Framed Pannelled Shutters (Two Panel) With Lock Rail And Panel Of 9Mm Bwp Commercial Ply Or 12Mm Veneered Particle Board Wiyh Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per (Is : 1003 Part-I , Kiln Seasoned And Chemically Pressure Treated Complete All As Specified And As Directed. , S&F Box Type Steel Window Side Hung Double Shutters With Provision For Desert Cooler/Ac(Inside For Wire Mesh & Out Side For Glass), Including Guard Bar,Hinges, Steel Handle, Tower Bolt And Steel Peg Stay Complete With Glazing Bar Dovetailed Or Welded And Fixed, Steel Window Shall Be Conforming To Relevant Is Complete All As Shown On Drawing No Ceuz/Td/1302/09, Sh 1/3 To 3/3 And Directed. Complete All As Specified And Directed. Note:- Wire Mesh And Sheet Glass Shall Be Measured And Paid Separately , S&F Steel Ventilators Top Hung Double Shutters (Inside For Wire Mesh & Out Side For Glass), Including Hinges, Steel Handle, Tower Bolt And Steel Peg Stay Complete With Glazing Bar Dovetailed Or Welded Including A Coat Of Red Oxide After Preparation Of Surface Before Fixing.Steel Window Shall Be Conforming To Relevant Is All As Specified. Note:- Wire Mesh And Sheet Glass Shall Be Measured And Paid Separately , S&F For Sheet Glass Palin/Coloured (As Per Directed By Engr-In-Charge) 3Mm / 5 Mm Thick Best Quality And Glazing With Rubber Packing, Screws Or Glass Putty In Squares Exc 0.5 Sqm Each Pane Complete All As Specified And Directed. , S & F For Stainless Steel Wire Cloth Of 0.36Mm Dia Wire And Average Width Of Aperture 1.40Mm & Fixed With Tacks Or Screws, Wire Staples, Etc Complete All As Specified And Directed. , S&F Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Wooden Grain Printed Pvc Sheet & Edges Will Be Painted To Match With Printed Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawingreinforced Complete All As Specified And Directed. , S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of Ms Tubes For Top & Bottom Rails. Ms Frame Shall Be Covered With Heat Moulded Wood Grain Printed Pvc Sheet 5Mm Thick X15Mm Wide Pvc Sheet Beading Used Inside Stiles And Rails And Decorative Pvc Beading Of 10Mm X 10Mm (900 ) Used Instead Of Exposed Portion Of Pvc Sheet Beading Pvc ‘C Channel Having A Pvc Sheet Strip Of 20 Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail. Panelling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded/Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Complete All As Specified And Directed. , S&F 100 Mm Long Mild Steel Butt Hinges, Cold Rolled, Medium Weight Complete All As Specified And Directed. , S&F For 125Mm Long Anodised Aluminium Barrel Tower Bolt Of Extruded Section Complete All As Specified And Directed. , S&F 150Mm Long Anodised Aluminium Handles, Cast Type Complete All As Specified And Directed. , S & F In 300Mm Long Aluminium Alloy, Anodized Sliding Door Bolt With Hasp Stapple ( Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy And Fixed Complete All As Specified And Directed. , S&F For 20 To 25 Mm Dia Stainless Steel Drapery Curtain Rod With Brass /Nickel Chrom Polish / Designer Lattos And Brackets Complete All As Specified And Approved By Engr-In-Charge Including Taking Out Old Pelmet With Curtain Rods Complete All As Specified And Directed. , S&F 300 Mm Long Mild Steel Ordinary Rat Tail Rod Pattern Spring Including Roller And Roller Plate Complete All As Specified And Directed. , S& F Floor Door Stopper Of Aluminium Alloy Body And Tongue ,Anodised ,With Hard Drawn Steel Spring ,Fixed In Floor Overall Length Of Cover Plate 140Mm Complete All As Specified And Directed. , S & F 2 Nd Class Hardwood For Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints, Complete All As Specified And As Directed. , S & F For Pvc And Cupboard Shelf/ Partition/ Frame / Shutter Of 18Mm Thick Side Of Panel Externally Impact Perfact Finish To The Shutter And Joined Together With Solvent Cement Adhesive 8Mm Thick (4Mmx2)X12Mm Wide Pvc Sheet Is Used As Gap Insert For Top & Bottom Rail, 18Mm X 1Mm Pvc Edge Lipping Is Done On Top & Bottom Side Using Pvc Solvent Cement Adhesive, Incl Hasp And Stable For Locking Purpose, Etc Complete As Per Direction Of Engr-In-Charge, Manufactures Specification And Drawing. , M&L For Block Boards 18/19 Mm Thick, Grade 2 Quality, I N T E R I O R Grade, Decorative Type With Decorative Face Veneer On One Face, Fixed With Screws To Timber Frame-Work For Partision Of Cupboard Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Straight Or Curved On Plan Exc. 6M Mean Radius Built In Cement Mortor 1:6., Etc Complete All As Specified And Directed. , M&L For Rendering 10Mm Thick In Cm 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , M&L For Rendering 15Mm Thick In Cm 1:4 On Other Than Fair Faces Of Brick Or Concrete Surface With Liquid Water Proofing Compound @ 200 Ml Per Bag Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed.(Note:- Liquid Water Proofing Compound To Be Measured Paid Separately) , M&L For Rendering 5Mm Thick In Ceiling Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , Supply Only Liquid Water Proofing Compound Complete All As Spesified And Directed. , M&L Plain Cement Concrete 1:4:8, Type D2( Using 40Mm Graded Stone Aggregate) 75Mm Thick As In Sub Base Of Floor/ Interlocking Paver Block Complete All As Specified And Directed . , M & L 25Mm Thick Cement Concrete Type B-0, 1:2:4 (Using 12.5 Mm Graded Aggregate) For Levelling Course In Floors Complete All As Specified And Directed. , M & L For Non Skid Joint Free Coloured Ceramic Floor Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exc 0.11 Sqm But N Exc 0.18 Sqm,In Floor Etc Set & Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface With 15Mm Thick Screed Bed Or Bedding Layer In Cm (1:6) Complete All As Specified And Directed. , All As Per Item No 35 Above But As In Skirting/ Dado Etc With And Including 10Mm Thik Backing Coat In Cement Mortar 1:4 An Wall Complete All As Specified And Directed. , M&L For Glazed Ceramic Coloured Wall Tiles (Textured And Design As Required) In Vertical Surface 450X300X7Mm Thick, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10 Mm Thick Rendering In 1:4 Cm Complete All As Specified And Directed. , M & L For Applying Two Coat Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. , M & L For Applying Two Coat Of Synthetic Enamel Paint On Old Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. , M & L For Preparing New Plastered Surfaces Of Wall And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Cement Primer And Over A Coat Of Putty Complete All As Specified And Directed. , Material And Labour For Apply Two Coats Of 100% Premium Anti Fungal Weather Coat Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistence As Per Is 15489;2004, Alkali & Fungal Resistence, Dirt Resistence Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.9 Litre / 10 Sqm Over New Surfaces Complete All As Specified And Directed. . Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Clain On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , M & L For Preparing New Plastered Surface On Ceiling And Applying Three Coat Of White Wash Complete All As Specified And Directed. , M&L For Complete Removal Of Exsting Treatment On Plastered Or Unplastered Surface Including Removal By Brooming Down With Steel Wire Brushing, Scraping Down Smoke Soot, Moulded, Moss, Efflorscent Salt, Trading Oil And Greasy Spots And Applying Two Coat Of Oil Bound Distemper On Walls Over A Coat Of Putty Complete All As Specified And Directed. , Material And Labour For Complete Removal Of Existing Treatment And Apply Two Coats Of 100% Premium Anti Fungal Weather Coat Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistence As Per Is 15489;2004, Alkali & Fungal Resistence, Dirt Resistence Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.9 Litre / 10 Sqm On Old Surfaces Complete All As Specified And Directed. Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Clain On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , M&L For Three Coat Of White Wash On Old Surface On Wall Including Preparation Of Old Surface Complete All As Specified And Directed. , M&L For Three Coat Of White Wash On Old Surface On Ceiling Including Preparation Of Surface Complete All As Specified And Directed. , Dismantling Of Kota Stone Slabs And Tiles Of Any Description Or Thickness In Laid Bedded And Pointed Floors, Aprons Etc Incl Screed Bed Complete All As Specified And Directed.. , M&L For Machine Cut Kota Stone Slab Flooring 18-20 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completeand Including 20 Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And As Directed. , M&L For Kota Stone Slab 18-20 Mm Thickin Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointedwith Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completeand Including 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And As Directed. , M&L For Rubbing And Washing Of Kota Stone Floor And Mirror Polishing On Kota Stone/ Stone Work Where Ever Required To Give High Gloss Finish Complete All As Specified And Directed. , M & L 20Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Steps, Jambs, Pillars, Window-Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite With Providing 15Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And As Directed.. , M&L Plain Cement Concrete 1:3:6, Type B1( Using 20Mm Graded Stone Aggregate) 75Mm Thick As In Plinth Protection Complete All As Specified And Directed . , Demolition Of Cement Or Lime Concrete In Any Despription Along With Tarfelt Treatment In Sunken Portion / Roof And Cement Mortar Bedding From Roof Removal Rubbish Out Side Md Land Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:2:4 Type B-0 Using 12.5Mm Graded Crushed Stone Aggregate As In Sunken Portion, Subbase, Etc Complete All As Specified And As Directed. , M&L For Water Proofing Treatment To Sunken Portition / Roof Etc. In Following Sequence:- (I) Properly Cleaning And Drying The Surface (Ii) Applying A Coat Of Bitumen Primer @ 1.2Kg/Sqm And Primer Shall Be Allowed To Dry Over Night. (Iii) Laying App Based Modified Water Proofing Membrane Of Weight Not Less Than 3Kg Per Sqm And Thickness Not Less Than 3 Mm, With 100Mm Overlaps, Sealed And Bonded To The Surface By Torchon Method (Iv) Applying Two Coat Of Bituminous Based Aluminum Painting @ 0.15 Kg/Sqm Each Coat On Water Proofing Treatment With Preparation Of Surfaces Complete All As Specified And Directed At Site. , S&F Vitreous China Squatting Pan Orissa Pattern Of Size 580X440Mm White With Integral Foot Rest (Excluding Flushing Cistern And Flush Pipes) Including Connection To Trap And To Flush Pipe Etc And Lime Concrete Bedding Including P Or S Trap Complete All As Specified And Directed. , M & L For Complete Removal Of Existing Sunken Treatment And Clean The Surface Of Sunken Slab , Appling Plain Cement Concrete B1 1:2:4 (20 Mm Aggregate Of ) With Wpc Of Thickness 100 Mm Finished Even And Fair With 1:20 Sloped Towards Corner Of Outer Wall & Pvc Pipe Of Require Dia Be Inserted At Corner Projecting Outside 20 Cm From Wall And 15 Mm Plaster Cm 1:3 With Wpc Is Also Applied Over Plain Cement Concrete And Returning Filling The Sunken Slab Complete All As Specified And Directed , M&L In Repairs Pvc Valve Less,Syphonic Action Type Flushing Cistern,Low Level ,White With Inlet Ball Valve,Float And Handle Including Brackets And Connection To Pipe And Fixing Of Chain And Pull Or Lever If Any Complete All As Specified And Directed. , Supply And Fixing Of Soap-Dish Chromium Plated Complete All As Specified And As Directed. , S&F In Repairs Of Brass Cp Tubular Towel Rail 20 Mm Dia 60Cm Long Between Flange With Brackets Etc As In Repair Complete All As Specified And Directed. , S&F Vitreous China Wash And Basin, White, Flat Back, Size 550 Mm X 400 Mm Incl Fixed On New Ms Bracket, Fixing Of Tap, Waste Coupling,Fitting,Waste Pipe And Union Incl 15 Mm Bore Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed Complete All As Specified And Directed. , S & F Pvc (Swr) Nani Trap / Floor Trap Plain Or Multi With Stainless Steel Grating Incl Joining To Waste Pipe With Solvent Cement Joint Dia Of Outlet 75Mm Bore Complete All As Specified And As Directed. , S&F In Repair 110Mm Bore Pvc (Swr) Bends Any Radius Complete All As Specified And As Directed. , S&F In Repair 75Mm Bore Pvc (Swr) Bends Any Radius Complete All As Specified And As Directed. , S & F In Repair 110 Mm Bore Pvc (Swr), Junction Single, (Single T) Equal Or Unequal Complete All As Specified And Directed. , S & F In Repair 75 Mm Bore Pvc (Swr), Junction Single, (Single T) Equal Or Unequal Complete All As Specified And Directed. , S & F In Repairs 110Mm Bore Pvc (Swr) Pipes Singles Socket In Any Length With Rubber Ring Joints Fixed To Walls / Floor Or In Tren1Ches Complete All As Specified And As Directed. , S & F In Repairs 75Mm Bore Pvc (Swr) Pipes Singles Socket In Any Length With Rubber Ring Joints Fixed To Walls / Floor Or In Trenches Complete All As Specified And As Directed. , M & L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exc 10Cm Girth Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Dia Old Serviceable / Unserviceable Steel Tubing Any Grade And Connections Cleaning For Re-Fixing Or Removal To Store Complete All As Specified And Directed . , All As Per Item No 70 Above But 20Mm Bore Complete All As Specified And As Directed. , S&F Steel Tubing Medium Grade ,Galvanized With All Fitting Such As Bend ,Elbow, Socket,Tees,And Fixed Complete To Wall Or In Ceiling Or In Floors Including Cutting Threading And Making Forged Bends On Pipes Ms Hooks Etc ,For 15Mm Bore Pipes Complete All As Specified And As Directed. , All As Per Item No 72 Above But 20Mm Bore Complete All As Specified And As Directed. , S&F In Repair For 15Mm Bore Bib Taps Chromium Plated With Crutch Or Butterfly Handle ,Screwed Down , Screwed For Iron Pipes Or Brass Ferrule Complete All As Specified And Directed. , S&F In Repair Cp Angle Stop Cock Of 15Mm Bore Screwed Down For High Pressure With Crutch Or Butter Fly Handle ,Screwed Both End For Iron Pipes Complete All As Specified And Directed.. , S&F In Repair Cp Wall Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe 15Mm Bore Complete All As Specified And As Directed. , S&Fixed In Repair 125 Mm Size Chromium Plated Shower Rose With Siwel Joint Suitable For 15 Mm Bore Gi Pipes Complete All As Specified And As Directed. , S&F In Repairs Pvc Connection 15Mm Size With Ptmt Nuts Of Length 450 Mm Long Complete All As Specified And As Directed. , S& F In Repair Rotational Moulded Polyethylene Water Storage Tank 500 Liters Capacity (Cylidrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Incl Brass Float Valve 20Mm Dia And Dismantling Water Tank. , S & F In Shelf Of Ptmt Fixed With And Including Chromium Plated Brass Screws And Wooden/Plastic Cleats (Minimum Weight 300 Grams) Complete All As Specified And As Directed. , S&F In Trepair Kitchen Sink With Drainage Board Made Of Stainless Steel 1.0 Mm Thick In Kitchen With Plug , Washer And Waste Including Bedding Layer In Cm (1:6) In Wall Or Including Fixing Cantilever Bracket And Connecting Union To Pipes Over All Size 915X460 Mm Bowl Size 410X330X160 Mm Including Taking Out Unserviceable Kitchen Sink Complete All As Specified And As Directed. , M&L For Stain Less Steel Plate Rack For Kitchen 1 Mm Thick Of Best Quality With Suitable Hanging Arrangement And Fixed To Wall Complete All As Specified And Directed .Note:- Size Of Plate Rack Should Not Be Less Than 900X1200 Mm And Weight Of Rack Shall Not Be Less Than 8.5 Kg Each Complete All As Specified And As Directed. , S&F In Repair Gun-Metal, Globe Or Gate Valves, 20 Mm Dia Bore Pipes With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And As Directed. , M & L High Strength Steel Deformed Tmt Bars 10 Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping Columns,Hookings Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.90 Mm Dia Or Securing With Clips, Etc Complete All As Specified And Directed. , M & L For Formwork Fair And Finished Surfaces To Sides And Soffits Of Floor Or Roof Beam, Beam Hauchings, Bands, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Complete All As Specified And Directed , M&L Reinforced Cement Concrete B1 1:2:4 Using 20 Mm Graded Stone Aggr As Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Etc Complete All As Specified And Directed , M & L For Formwork Flat Fair Finished Surfaces To Sides And Soffits Of Floor Or Roof Beam, Beam Hauchings, Bands, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Complete All As Specified And Directed , M&L Reinforced Cement Concrete M-25 Using 20 Mm Graded Stone Aggr As In Beams, Bands, Cantilvers, Bressummers, Linters, Chajjas, Etc Over 1.5M Span Etc Complete All As Specified And Directed , M&L For Mild Steel Bars (Tmt Bars) 5Mm Dia And Over Upto And Including 10Mm Dia In Strriups,Spacers And Binders Complete All As Specified And Directed. , M & L For Precast Cement Concrete 1:2:4 Type B-1 (Using 20Mm Graded Crushed Stone Aggregate) As In Manhole/Drain Slab Cover All As Specified And Set In Cm 1:4 Complete All As Specified And Directed. , Excavation In Trenches N.Exc 1.5M Wide And N.Exc 1.5M In Depth For Foundation Or Etc, For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc N.Exc 10 Sqm On Plan And N.Exc 1.5M In Depth And Getting Out In Hard Dence Soil, Complete All As Specified And Directed. , Returing, Filling In Trenches, Incl Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm In Hard/Dense Soil Complete All As Specified And Directed. , Removing Excavated Material (Soil) To A Distance Not. Exc. 50 Mtr And Depositing Where Directed At A Level Nexc 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. , Demolition And Breaking Up 150Mm Dia Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete ) And Set In Cement Mortar Complete All As Specified And Directed. , M&L For Concrete Bed To Drain Pipes Including Packing Under, And Haunching Against The Sides Of 150 Mm Bore Pipes In Cement Concrete 1:3:6 Type C-2 ( Using 40 Mm Graded Stone Aggregate) After They Are Laid And Tested Complete All As Specified And Directed. , M&L For 150 Mm Bore Salt Glazed Stone Were (Sgsw) Drain Pipe Grade A Laid To Slope In Tranches And Jointed In Cement Mortar (1:1) Including Necessary Testing For Ensuring Teak Proofing Complete All As Specified And Directed. , M & L For Cutting Into Existing Manhole For Connecting New Drains And Making Good To Pipes And Rendering Cutting Out Existing Benching For And Forming Branching For And Forming Branch Channel (1/2 Round Or ¼ Section ) In Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate Smooth Finished And Reforming Benching As Specified And Directed For 150Mm Dia Of Pipe Complete All As Specified. , M&L For 60Mm Thick Machine Pressed Precast Concrete Interlocking Paver Block (Glossy Finish) Of M-35 Gde Of Approved Shape, Size And Colour Conferming To Is 15658-2006 And Laid Over And Including 25Mm Thick Grid/Sand Cushion Complete All As Specified And Directed. , S & F For Precast Cement Concrete Type B-1 (1:2:4) (20 Mm Graded Stone Aggregate) As In Kerb And Edging To Road And Footpath Etc, Including Chamfered, Weathering, Throating, Etc Setting In Cm(1:4) Complete All As Specified And Directed. , S & F In Repairs Ms Framed Work As In Doors Or Gates Of Angle Iron, Door Frame Or Other Section With Gusset Plate, Rails, Braces And Stair Case Etc Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering Etc, To Prepared For Hanging Or Sliding With Including Either Hooks And Hinges Also Fastening Grills, Grating, Hold Fast Of Doors And Windows Chowkat Etc, With Ends Of Bars Shouldered And Or Riveted, Or Forget Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walkways; Railings; Framework Of Water Tanksand Fixing And Similar Work Confirming To Fe 290 Gde E-165 Complete All As Specified And As Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing), And Rubbish Off The Premises Complete All As Specified And Directed. , M&L For Cement Concrete B1 1:2:4 (20Mm Aggregate) In Foundations, Filling And Mass Concrete Complete All As Specified And Directed. , M & L Cement Concrete Type B1 1:2:4 ( 20 Mm Graded Aggregate) As In Coping, Bearing Course, Manhole/ Drain Channels Etc In Including Necessary Formwork Complete All As Specified And Directed. , M&L For Preparation Of New Steel Surfaces Exc 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. , S&F 600Mmx450Mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers, Complete All As Specified And Directed. , M&L For Preparation Of Old Steel Surfaces Exc 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. , (Schedule-A Part-Ii E/M Works) Taking Down Carefully Unserviceable Aluminium Point Wiring Complete (Light, Fan Socket, Bell Or Power) With Fitting Such As Switches, Ceiling Rose Lamp Holder, Regulators, Sockets, Light Fittings Etc. And Keeping In Safe Custedy For Taking Credit Complete All As Specified And As Directed. , (Schedule-A Part-Ii E/M Works) Taking Down Carefully Unserviceable Aluminium Point Wiring Complete (Light, Fan Socket, Bell Or Power) With Fitting Such As Switches, Ceiling Rose Lamp Holder, Regulators, Sockets, Light Fittings Etc. And Keeping In Safe Custedy For Taking Credit Complete All As Specified And As Directed.
Contract Date: Jun 15, 2026 Contract Value : 31.73 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu and Kashmir View Result →
38.
Defence #11213485 AOC
Tender For Additional / Alternator To P-266 Of 5 Afdc And Provision Of Misc E/M And B/R Services In Various Buildings And Certain Minor Works At Afs Pune Under Ge Af Lohegaon.; 1 Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering all as specified and directed. 2 Dismantling timber in fillets rails, posts, rafters, purlins etc over 40 Sqcm in section in unframed work 3 S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 4 S&F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Eaves boards, fixed with self tapping screws as specified 5 S & F Rolled Mild Steelroof trusses(framed),trussed ,purlins ,rails and fastenings etc.,confirming to Fe 410 - S including distance pieces, cleats, etc., complete. 6 S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering.doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening andfixing complete (Eaves board fixing ) 7 S & F 6mm thick asbestos cement plain building boards fixed to steel frameowrk with screws all as specified and directed ( For Eaves Board). 8 S &F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-w (Gde E-250 quality A) all as specified and directed. 9 M & L for Preparation of newsteel/iron surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paintover red oxide primer for material and labour complete all as specified. 10 M & LPCC B1 1:2:4 (12.5mm graded aggregate) for in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. (Note :- Bed boxes and Coping on wall to fill up the gap) 11 Demolition of Brickwork or stone/boulder masonry/PCC bloack masanory,built in cement motar all as specified and directed. 12 S & F brick work with fly ash bricks,straight or cuved on plan exc 6m mean radius built in CM 1:4all as specified and directed. (Note : 1. For filling the Gap between sheet and wall 2. Clsoing of ventilaots ) 13 Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge 14 Material and labour for suspended false ceiling usinganodized aluminum snap grid frame work.Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete. Perforated particle board/tiles for insulation and acoustic purposes, 60 x 60 cm size, fixed on snap grid 12mm thick confirming to IS 2095, 2995 Part I fixed with 25mm dry wall screws @ 230 mm C/C with screw driver to match surface attachment. Finally board have to be joined and finished to have a flush look using jointing compound/tape as per manufacturer instruction. With Designing as per direction in two steps complete all as specified and directed by Engineer in Charge. 15 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:4and is to be finished even and smooth with out using extra cement complete all asspecified directed 16 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 17 M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than than 50gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint or required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.9 litre/10 sqm over new surfaces/old surfaces of wall all as specified and directed. 18 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out hard dense soil 19 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting poin 20 Hard coare of broken stone aggregate, of gauge n.exc 60 mm 21 M&L for cement concrete Type D -2 1:4:8 (40 mm graded agg) in foundation fillig/path and mass concrete 22 Formwork to sides of flat concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter 23 M&L Forming Contraction (Dummy) joints 30 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade A in plinth protection 24 Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) 25 S &F 605 x 605 mm Anodised aluminium snap grid frame work for false ceiling all as specified 26 Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified 27 Dismantling boarding, any description, fixed in any position with nail 28 Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete 29 M&L rendering 15mm thick on surface of concrete surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 30 Demolition of stone / block masonry built in CM 1:4 31 M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) and set in CM (1:6). 32 Preparing new wall surface, providing and applyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of oil emulsion 33 Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners withholdfasts and brackets, complete 34 S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 35 S&F Sheet glass 5.5 mm thick ordinary quality and glazing fixedin aluminium doors squareexc 0.5 sq. m in each pane 36 S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers 37 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, 38 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats 39 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) 40 M & L for 100mm thick PCC type B-2 (1:2:4) using 40mm graded aggbnas in flooring finshed even and smooth w/o using extra cement. 41 M & L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded agg finished even and smooth w/o using extr cement. 42 M & L for nonskid coloured ceramic tiles 7 to 8 mm thick (square/ rectamgular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors (Superior/ Premium quality), set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15mm thick screed bed in CM (1:6) complete all specified and directed. 43 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer in Charge. 44 M & L fire resistant paint on steel surface over a coat of primer complete alll as specified (Note: The primer is of same material of 1:1 dilution application) 45 S & F of mineral fibre reinforced false ceiling tiles (all height)of size 595X595 mm of approved texture, design and pattern. The tiles should have humidity risistance RH of 99%, Light resistance greater than 85% , thermal conductivity K=0.052-0.057 W/mK, Fire performnce As per (BS476 Pt-6&7) in true horizontallevel suspended on interlocking T-grid of hot dipped all around ganvanisedIron Section of 0.33mm thick (galvanised @ 120GSM)bcomprising of main T runner of 15 X32 mm of length 3000mm, cross T of size 15X32 mm of length 600mm to form grid module of size 600X600 mm suspended from ceiling using galvanised Mild steel item ( galvanised @ 80GSM) 50mm long 8mm outer dia M-6 Dash Fastner, 6mm diameter fully threaded hanger rod upto 1000mm length and L-shped level adjuster of size 85X25X2mm, spaced at 1200 mm center to center along main T, the system should rest on perpfery walls/ partition with the help of GI perimeter wall angle of size 24X24X300mm made of 0.40mm thick sheet, to be fixed to the wall with the help of the plastic rawl plug at 450mm center to center & 40mm long drywall S.S screws. The exposed bottom portion of all y- Sectionused in false ceiling support system shall be prepainted with polyster baked paints, for sll heigth. the work shall be carried outas per specification drawing adn as per the direction of the Engr-in-charge with 16mm thick Bevelled traingular Mineral Fibre faalse ceiling (NRC 0.5 to 0.6)) 46 Taking down and of chowkats or frames exc 1.5 sqm n exc 4 sqm each 47 S & F Anodised aluminium frame powder coated to (minimun thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 48 S & F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,ruber neoprene packing, handk=les 2 Nos in each door, hinges, anodises aluminium snap beading screws etc. complete all as specified. 49 Cuting holes exc 150 sqcm but not exc 400 Sqcm into or through brick walls built in cement mortar of any description and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-I as required 50 m&L two coats or Oil Bound distemper on Cement concrete surface over a coat of primer as per the shed directed by the engineer-ncharge, complete all as specified. 51 M&L for treating small articles such as ends of posts, holdfasts etc with tar or coal tar black paint; area exc 0.1 Sqm but n exc 0.5 Sqm each 52 S&F sheet in repairs glass 4.8 mm thick exc 0.5 sqm area ordinary quality and glazing with oil putty/rubber gasket fittings all as specified and directed. 53 M & L in repairs for 12mm Prelaminated particle board, interior grade, prilaminated both side with decorative choice lamination fixed with screws to timber/Aluminium frame work complete all as specified and directed. 54 S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 1000 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I 55 S & F in repairs 20 mmBrass valves ,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed 56 S&Fbib tap cast copper alloy chromium plated butterfly handle screwed down screwed for iron pipe completed (15mm dia tap). 57 S&F GI tubingof 15 mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 58 S&F GI tubingof 20mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 59 S&F GI tubingof 25mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 60 S&F25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 61 S&F20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 62 Dismantling wrought iron or mild steel work of any description not otherwise provided for. 63 S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St 240 all as specified and directed.(Eaves Baords) 64 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 65 Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar including all quoins, arches , pillars etc all as specified and as directed 66 M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified 67 M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified 68 M&L for reinforced cement concrete M 20 using 20mm crushed stone aggregate as in roof slabs supported on walls surfaces of concrete flat all as specified. 69 M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement. 70 M&L for preperation of new concrete /plastered surface of any description, two coat of plastic emulsion paint over a coat of primer complete all as specified and as directed complete all as specified and as directed. 71 M&L for Powder Coated (Minimum thickness of powdercoating 50 micron)Anodised aluminium frame of standerd section for doors, windows, ventilators and partitions withdoublerebates including joining cleat for fixing etc. complete all as specified 72 S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (For sliding window ) 73 M&L sheet glass 4.0mm thick figured glass, pin head type and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed 74 M&L for vetrified ceramic tiles 10mm thick full body(Dark shade/Ultra Charged/Double charged ) (square/rectangular) polished, area of each tilesexc 1.00 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 75 M&L for vetrified ceramic tiles 10mm thick full body(lightshade ) (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 76 S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediatechannel at 457 mm centre to centre and including Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified 77 S&F for 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish(Frame work for ceiling shall be measured and paid separately) 78 Removal of existing Rifle racks including all fixing stell bolts and cement work all as specified work 79 M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified 80 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 81 M & L for 25mm thick PCC 1:2:4,type B-0, (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing the surfacesrough to receive screed bed complete as specified and directed. 82 M&L for machine cut mirror polish kota stone slab flooring 20-25mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 83 M&L for machine cut mirror polish kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10mm thick cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 84 Fixing and grouting of new steel Rifle racks on the floor including necessary fixing bolts and necessary arrangements of grouting and grouting material all as specified. 85 M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 86 S&F for Mild steel ,plain black sheet of minimum 0.8mm thickness for Hoods cover for Rolling shutters;cladding to door shutters/Hangar doors ; water tank platforms etc with plain 40mm lap joints or welded/riveted seams including ,bending, turning up, mitred angles , stopped ends,outlets,etc. as required all as sprcified and directed by Engr-in Charge. 87 M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. 88 Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. including sorting out serviceable and unserviceable light fitting and keep serviceable fitting in safe guard for reuse as required on site. 89 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 90 Taking down cearfully byunscrewingthe unserviceable DB Boxes, MCB distribution boards SP & TPN with porcelain cutouts etc all as directed. 91 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and capingwith all fittings/fixture etc andsurface typePVC box, cover plate all as specified and directed by Engr-In-Charge.(a) Onelight point controlled by one switch. 92 (b) One 3 pin socket 5 A on independent board. 93 (c) One 3 pin socket 5 A on same board. 94 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,with all fittings/fixture etc andsurface typeModular , PVC box cover plate, frame all as specified and ndirected by Engr-In-Charge. 95 S & F Sub Main Wiringwith FRLS PVC Insulatedmultistranded copper conductorwires ofsize2x6.0 sq. mm + 1x6.0 sq. mm earth wire in casing caping complete as directed.Note : for Item No 95 One run of phase wire one run of Neutral wire and one run of Earth wireand one run of casing and capping shall be meassured and as one length. 96 S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps.including fixing concealed in wall and making good the disturbed surfacecomplete all as directed 97 Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 98 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connections as directed 99 S&F MCB SP 240 volt 6 to 32 A C series complete 100 S &F for MCB SPN 40-63 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. 101 Supply and fix Modular switch 1 way 6A, 1 module 102 Supply and fixmodular Socket, 6A - 2/3 pin combined 2 moduler 103 Supply and fixModular switch 1 way 16A, 1 module 104 Supply and fixmodolar Socket 6A/16A - 2/3 pin combined2 module, 105 Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm 106 S & F Modular white cover plate with frame 2 Module 107 S & F Modular white cover plate with frame 3 Module 108 S & F Modular white cover plate with frame4 Module 109 S & F Modular white cover plate with frame 6 Module 110 S & F Modular white cover plate with frame 8 Module 111 Supply, Fixing , Testing and Commissioning of Single phase isolation transformer to be installed at input power supply of L-2 switch,via 16 Amps MCB and with power earthing point specification as follows 1Ph, Capacity 1KVA, Input 230V AC ±10%,Output 230V±10%,50 Hz,cooper wire,work efficiency more than 95%,potential between earth to neutral less than 1 Volt with all standard fitting as per direction of Engineer in charge 112 Supply, Fixing , Testing and Commissioning ofIsolation transformer of capacity 5 KVA, single phase ,50 Hz , Copper wound , Air cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 240+-5% and output voltage range 240+-5% ,Ratio 1:1 , indoor , efficiency more than 95 % , Potential difference between neutral to earth less than one volt with all standard fittingsas per direction of Engineer in charge 113 Supply, Fixing , Testing and Commissioningof Three Phase Surge Protector Device to be installed at input power supply of L-2 switch all as specified and directed by Engr-In-Charge 114 S&F wall mounted Industrial grade metal enclosure box made from 3mm thick CRCA sheet consist of following Items:-(a) Panel mounting Industrial grade socket/plug outlet 16 A,IP44(b) SPD ,1.5kv,320A,20kA - 1 Nos(c ) MCB SP 16 A- 1 Nos 115 S&F Vertical double door Distribution board TPN 4 way 125 A rated busbarconsisting ofMCCB. 63 A 18KA - 1 Noincluding fixing on wallsurface and making good the disturbed surfacemaking all nacessary incomming and out going connections using proper size copper thimblescompleteall as required on site all as directed 116 Supply and fixing in replacement sheet metal enclosure with DBs ( grouted in walls) double door type for MCBs 12 ways with 200 Amps 240 volts rated bus bar incl taking down old DB all as specified. 117 Material and labour for taking down serviceable Fire Alarm panel from one location and re-install the same at same /another location including fixing brackets/nut bolts incl testing and commessioning of the same all as specified and directed 118 Material and labour for taking down serviceable Smoke / Heat / Fire detector from one location and re-install the same at same /another location including necessery cable upto Fire alarm panelincl testing and commessioning of the same all as specified and directed 119 Supply and fix adressable smoke Detectors Complying with and type certified to EN-45 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 all as specified. 120 Supply, install, testing and comissioning of adessable break glass manual call pointincluding sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete. 121 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade. 122 Material and labour for taking down serviceable split AC of capaicty upto 2.0 TR from one location and re-install the same at same /another another location including fixing brackets, gas charging, brazing and additional required copper piping incl testing and commessioning of the same all as specified and directed 123 Supply, Install testing and commessioning Single pole and neutral enclosure 240 Volts with a two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed 124 Material and labour for providing point wiring with two runs of 4 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,ISI Marked complet for housing one 15 to 20 A Switch / socketscomplete 125 Supply, Install , Testing and Commissioning of wall mounted enclosure box made from 3mm thick CRCA sheet enclosure consist of following items for 3 Phase 2 AC timer & Controller of Auto switching timer unit suitable for operate 8.75 TR package type AC:-(a) Timer - 1 No(b) Contactor 32 amps - 2 No(c ) Indication lamp - 1 No
Contract Date: Jan 09, 2026 Contract Value : 44.46 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
39.
Defence #11213475 AOC
Tender For Up gradation Of Radio Communication System At Certain Labs At 9Brd Afs Pune Under Ge Af Lohegaon; 1 Dismantling boarding, and ceiling boards (fire, pulp,insulation ) etc insulation boards/slabs/blankets any thickness including cover any description, fixed in any position with nailscomplete all as specified and as directed. 2 M&L 12mm fiber board/tiles of flame retardent type treated on one face, insulation and accoustic purposes, 60x60 cm in size suspended false ceiling incl GI powder coated grid work using 2.5mmx 23.5mmx1.5mm main tee, 25mmx23.5mmx1.28mm crossed Tee & 25mmx23.5mmx1.2mm angle fixed to wall for false ceiling incl necessary supporting hanger with 3mm dia GI wire & wire J bolts washer nuts for securing frame work to ceiling, suspended @ 125 cm C/C bothways, size of grid shall be 605x605mm complete all as manufacture instruction & specified & complete all as specified and as directed. 3 Taking down Chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. 4 Taking down Chowkats or frames exc. 1.50 Sqm but n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. 5 Taking down Aluminium Frames of any description and size exc 1.5 Sqm but n exc 4.0 Sqm made up of aluminiumframe including Shutters all as specified and as directed. 6 S&F pressed steel door frame of size 105X60mm with one or more rebates including necessary fixing lugs,hinges,lock strike plate etc complete all as specified and directed. 7 Providing, cement concrete type B11:3:6 (20mm graded aggregate) as in chowkhat filling ,coping kneelers, apex stones, bed plates, kerbs as directed 8 M & L for Factory made of 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides: supplied and fitted to chowkats complete all as specified and directed . 9 M & L for preparation of new or previously untreated surface of wood of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamelled paint over one coat of pink primer complete all as specified and directed 10 S & F SS butt hinges 100mm fixed to doors and chowkhats all as specified and directed. 11 S & F for 150 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed . 12 S & F for 150 mm sizealuminium anodised barrel tower boltof extruded sectioncomplete all as specified and directed . 13 S & F for 300 mm Sliding door bolt aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. 14 S & F for aluminium frame powder coated for doors, windows, ventilators, window shutters and their sections with one or more rebates including joining cleat,rubber gasket, screws and all necessary fittings for fixing etc. complete all as specifiedand directed. 15 S & F for aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, handles2 Nos in each door, hinges, anodised aluminium snap beading screws, tower bolts suitable mortice lock etc. complete all as specified and directed. 16 S & F for Anodised aluminium powder coated window and ventilator shutters, any type without sash bar, aluminium section weighing 0.50 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, hinges, star locketc. complete all as specified and directed. 17 S& F Sheet glass 4.0 mm thick, ordinary quality and glazing with oil putty or aluminium clips fixed to frames in square exc 0.5 sq. m in each pane complete all as specified and directed. 18 S & F Sheet glass 4.0 mm thick fixed in repair ordinary quality and glazing with oil putty or aluminum clips in square n exc 0.5 sq. m in each pane including hacking out old broken glass from frame complete all as specified and directed. 19 S& F 12 mm Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations fixed in repair with screws to timber frame work complete all as specified and directed. 20 M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 21 M & L applying two coats of synthetic enamel paint over a coat of red oxide primeron steel surfaces over 10 cm width or girth including preparation of new steel surfaces 22 S&F FD 120 door frame single rebate with door shuter of following specification:-(i) FD 120 door frame of profile of size 125x55 mm constructed from 1.6 mm (12 SWG) thick skin pass galvanised iron sheet (conform to IS 277) and shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fastners for installation on a finished plastered masonary wall opening. Frame finished with polyurethane/epoxy polyester powder coated with 60 micron dry film thickness. Frames shall be filled with fire rated puff and gaps shall be sealed with silicon sealant complete all as specified and directed.(ii) S&F FD 120 Door shutter 46 mm thick fully flush double skin door insulated with vision lite glass 6 mm thick clear borosilicate fire rated glass of size 200mmx300mm. Door shutter constructed from 1.2 mm thick (18SWG) skin pass galvanised iron sheet (conform to IS 277).The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware made up of rockwool/mineral wool. Intumescent seals 15x2mm to be provoded all around the door in addition to grooved smoke seal. All doors shall be factory made for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The edges should be interlocked with a bending radius of 1.4 mm. All doors finished with polyurethane/epoxy polyester powder coated with 60 micron dry film thickness complete all as specified and directed. 23 Providing and applying 5 mm ESD epoxy self-smoothening flooring on existing sound surface having moisture content less than 5 %. Surface preparation includes removal of existing ESD flooring , grinding of existing surface, proper cleaning, removing of loose mortar, paint residuals, curing compound residues, repairing of floor cracks and dents using epoxy putty. Application of Nitoprime 25-epoxy penetrating primer for concrete surface, using brush or roller and allow to cure for 8-10 hrs(depending upon temperature).Application of Nitoflor EU5-High Strength self-smoothening epoxy underlay at 2 mm thickness, coverage as per the TDS @ 7.7 m2 for 2 mm thickness. Nitoflor EU5 is a three component product includes base, hardeners and filler. All 3 components shall be mixed at least for 3-4 minutes at 500 rpm and the mixed Nitoflor EU5 should be spread to uniform thickness on the prepared surface using either a squeegee or a notched trowel. Prepare copper grid as per site condition and connect the same to earthing point. Copper strips shall be between 25mm wide & (100 microns) thickness fixed at 3mx3m grid or as per technical requirement. Mixing and application of Nitoflor SL Conductive Undercoat over primed surface using suitable brush or roller as per recommended coverage as per technical datasheet. Now mixing all components of Nitoflor SL Conductive Top Coat- Epoxy resin based static conductive self-smoothening system floor topping having thickness of 3 mm. Properties: Surface Resistance (BS 2050) Nitoflor SL Conductive – 25 x 103 - 1 x 106 Ohms, Compressive Strength at 7 days (ASTM C579) – 60 N/mm2, Flexural Sterngth at 7 days(BS 6319 Part 3) > 20 N/mm2, Tensile Strength at 7 days (BS 6319 Part 7) > 11.5 N/mm2, Volume Solids – 100 % using slow speed drill and poured on primed and prepared surface at 2 mm DFT. Now level the material using serrated trowel and roll the same with spiked nylon roller to remove slight trowel marks and entrapped air from the material etc. complete as per manufacturers specification. Make: Fosroc or equivalent.(Note: Complete procedure to be done by authorised applicator and certificate and warranty to be submitted to the accepting officer.) 24 Providing and appying 3 mm thick epoxy floor coating on existing sound surface having moisture content less than 5 %. Surface preparation includes grinding of existing sound surface (if required), proper cleaning,removing of loose mortar,paint reduals,curing compound residues,repairing of floor cracks and dents using epoxy putty.Application of Nitoflor EU5-High Strength self-smoothening epoxy underlay Nitoflor EU5 consists of special resins and graded aggregates formulated to withstand chemical attack and impact shock. The mixed Nitoflor EU5 should be spread to uniform 2.0 mm thickness on the prepared surface using either a squeegee or a notched trowel. The subsequent use of a spiked roller, eliminates air entrainment. Application of Nitoprimer 25-Solvent free epoxy resing based primer for concrete surface, coverage @ 5.5-6.0 Sqmt/ltr using brush or roller and allow to cure for 8-10 hrs(depending upon temperature). Mixing ofbase and hardener of Nitofloor SL 1000 - Flow applied 1 mm thickepoxy resin based floor topping using slow speed drill andpoured on primed and prepared surface at coverage - 15 m2/ Pack for 1 mm DFT. Now level the material using serrated trowel and roll the same with spiked nylon roller to remove slight trowel marks and entrapped air from the material etc.complete as per manufacturers specification.The EpoxyCoating material should posses following properties:-Compressive strength > 65 N/mm2,Flextural Strength @ 7 days>23 N/mm2Tensile Strength @ 7 days> 12 N/mm2,Pull Off Adhesion Strength (ASTM 4541)>1.5 N/mm2 ,Shore D hardness (ASTM D2240) @ 7 days > 70, Abrasion Resistance (ASTM D 4060) - 0.083 mg/cycle loss of weight.Make: Fosroc or equivalent.(Note: Complete procedure to be done by authorised applicator and certificate and warranty to be submitted to the accepting officer.) 25 Dismantling of old Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortars including backingin floors, aprons etc. 26 M& L hand cut kota stone slab flooring 20-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including screed bed 15 mm thick in cement mortar (1:4), including rubbing and mirror polishing complete all as specified and directed. 27 M& L hand cut kota stone slab flooring 20-20mm thick as in vertical surface such as skirting and dado jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including backing coat of 10 mm thick in cement mortar (1:4), including rubbing and mirror polishing complete all as specified and directed. 28 Demolition of brick work /stone masonry/pcc block masonry built in cementmortar of any description all as specified and directed. 29 M&L for Brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete. 30 Taking down cement plaster on brick/stone walletcincluding raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. 31 M&L for 10mm thick rendering in CM (1:6) on internal surfaces of brick work or concrete surfacesfinished even and smooth without using extra cement, complete all as specified and directed. 32 M & L for prepartion of newly plastered surfaces of wall and priming plastered surfaces with alkali resistant primer and applying two coats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturers specification over 3mm thick putty (in three layers) complete all as specified and directed. 33 M & L for complete removal of existing treatment of old surfaces of wall and applying distmepring with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved munufacutre of required shade and colour over 2 mm wall care putty in two layers complete as per munufacuters specification two or more coat all as specified and directed. 34 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level). 35 M&L for 100mm thick PCCtypeB-2 (1:4:8) using 40mm graded agg as inflooring finished even and fair w/o usin extra cement . 36 Sand filling under floor or in foundation including watering and consolidation 37 M&L forpre-cast concrete machine pressedrubber moulded glossy finished interlocking paver Blockof 60mm thick M-35 grade any colour (as approved) and design Over sand cushioning complete includingwith using grey cement and pigment any shape and size confirming to IS-15658-2006 all asspecified. 38 Supply, installation,Boring, erection, testing and commissioningof Copper bonded(150 micron) MS solid rod electrode of dia 17.2 mm and 6 mtr long with high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Earthing Electrode shall bemade by embedding copper bonded MS Rod electrode in 100mm dia macronite conductive concrete made by mixing high purity conductive granularmixed with cement in the ratio2:1 (2 part of high purity electriclly conductive granular and 1 part cement and one litre of water per kg of mix ). The earthing electrode shall be augured inbore hole of dia not less than 100mm and6 Mtr depth. The conductive material shall confirm to BIS: 3043-2018. The rod shall be embedded in conductive concrete at factory with concrete having resistivity 0.040 Ohm-m. The top edge of the electrode shall comprise of plate provided with 04 holes for connections of the earthing strip,including brass nut bolts for connections of the strip the copper strip shall be duly brazed/welded with connection terminal of earthing rod, including FRP square chamber cover 300mm x 300mm x 250mm with top cover complete all as specified.All the material such as copperbonded MS rod and concrete mix shall be Ph nuetral, chemicaly inert and non corrosive complete all as specified and directed by Engr-In-Charge.i) The contractor shall submit type test report issued by the CPRI for high purity, electrically conductive earthings , confirms to rated short time withstand current20 KA per sec. ii) The factory made electrode shall be tested at factory and test report shall be submitted.iii) Factory testing of individual earthing shall be carried out in presence of rep of accepting officer and report shall be submitted.iv) The contractor shall obtain make approval for high purity electrically conductive granular duly by submitting certificates conforming to resistivity is 0.001 ohms by granular manufacturer.v) On installation of earthings at site, 04 to 05 Nos earthings shall be connected in grid to achieve less then 1 ohm resistance of grid, If desired resistance is not achived the contractor shall redo the same without any extra cost. vi) The contractor shall submit certificate issued by OEM of earthing electrode starting that The desired maintenance free earthing resistance less than 1 ohm. The year will be maintained for not less than 25 years. 39 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal cover block made out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer. 40 S & F copper earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc.and connecting with earthing test point oras required complete all as directed.
Contract Date: Jan 21, 2026 Contract Value : 32.21 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
40.
Public Administrative Department #11212849 Price Bid
Tender for Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Fabrication, Supplying And Fixing Class B Galvanised Single Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipe With Tightening Bolts Complete As Required , Fabrication, Supplying And Fixing Class B Galvanised Double Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipes With Tightening Bolts Complete As Required. , Supply And Fabrication Of Pole Protection System Made Up Of 8 Swg Steel Wire Mesh Of Size 25Mm X 75Mm Rectangular With 50Mmx50mmx6mm Ms Angle Iron For Supporting The Mesh I/C Mv Danger Plate And Grounding The Protection System In Suitable Quality Of cement concrete Etc As Reqd. , Providing And Laying In Position M25 Grade Reinforced Cement Concrete Foundation Of Size 450 Mm(L) X 450 Mm Wide And 1000 Mm Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Rewinforcement Of Cold Twisted Bars Of 12 Mm Dia -960Mm Long (Approx.) - 8 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 1400 Mm (Approx.) - 6 Nos. (With 150 Mm Spacing) As Required With Supplying And Positioning Of 4 Nos Foundation Bolts Of Size 16 Mm Dia And 600 Mm Long, J Type I/C 2 Nos Template Anchor Plates Of Size 225 Mm X 225Mm X 3 Mm And Providing 63 Mm Dwc Hdpe Pipe For Cable Entry & Exit As Required For 5Mtr Pole , Fabrication, Supply & Erection Of 5.0 Mtr Height, Minimum 3 Mm Thick, Bottom Dia Of 130Mm & Top Dia Of 70Mm, Base Plate Of Size 225 X 225 X 12 Mm Thick Flange Mounted Hot Dip Galvanized Octagonal Pole Made From Ht Steel Plate, Window With Flash Cover With Full Vertical Window Cover At Appropriate Height From The Base Plate On Existing Cement Concrete Pedestal As Required. L/C Supplying And Fixing Of 6 Mm Thick Laminated Mounted Sheet Inside The Window And L/C Providing And Welding 3 Nos. Gi Strips 4 Mm Thick Of Suitable Length And Having Suitable Size Tapped Holes As Reqd, Terminal Block Suitable For 25 Sq Mm Conductor - 4 Nos. & Shorting Links On Din Channel L/C Providing And Fixing Din Channel Of Suitable Length, 6 Amp. Spmcb C Curve Characteristics, Earth Stud, Cable Support Clamp Suitable For Upto 4X25 Sqmm Cable. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is Code Etc As Required , Fabrication, Supplying, Installation, Testing, Commissioning Of 12 Metres Semi High Mast System With Its Accessories, Mast Shaft Shall Be In One Section, Hot Dip Galvanized 4Mm Thick(Single Dip) Inside & Out Sides &Sultable For Wind Velocity As Per Is 875 Part3.There Shall Be In Longitudinal Seam Weld Per Section And No Circumferential Weld. It Should Also Included Accessories For Seml High Mast Head Frame,2 Point Suspension System,5 X 2.5 Sqmm Copper Conductor With Steel Wire Rope 5Mm Dia. (7/19 Construction) Single Drum Winch ,Galvanized Lantern Carriage Arrangement Suitable For 4/6 Nos. Flood Light Luminaries Symmetrically And Its Control Gears Boxes And Lighting Finial, The Mast Shall Have Integral Type Manual Tool Mounted At The Base Compartment Of Its Raising And Lowering Operation With Foundation Bolts And Anchor Plate And Control Panel Housing Suitable Reinforced Cement Concrete (1:2:4) Shallow Foundation Of Size 1M(L) X 1M Wide And 2M Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Reinforcement Of Cold Twisted Bars Of 12 Mm Dia -2100Mm Long (Approx.) 16 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia 3700 Mm (Approx.) 13 Nos. (With 150 Mm Spacing) As Required With Positioning Of Foundation Bolts And Providing Dwc Hdpe Pipe For Cable Entry & Exit As Required For The Semi High Mast Considering The Safe Soil Bearing Capacity At Site As 10T/Sqm At 2Mts. Depth With All Material I/C 4 Nos S.P Mcb,1 No. Double Pole 16Amp. Mcb Etc As Reqd. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is. , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection,Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 45 Watt , Led Flood Light, Powder Coated Pressure Die Cast Aluminum (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip-66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 100W , Supply And Fixing Of 32Mm Dia X 1 Meter Long G.I. Pipe (Medium Class) Bracket For Mounting Of Fluorescent/Hpmv/Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos 25Mm X 6Mm Flat Iron Clamps With Nuts, Bolts And Washer , Painting The Flat Iron With Primer And Finish Paint Etc. As Reqd. , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Un-Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*4 Sqmm
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
41.
Public Administrative Department #11212721 Price Bid
Tender for Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Supply And Fabrication Of Pole Protection System Made Up Of 8 Swg Steel Wire Mesh Of Size 25Mm X 75Mm Rectangular With 50Mmx50mmx6mm Ms Angle Iron For Supporting The Mesh I/C Mv Danger Plate And Grounding The Protection System In Suitable Quality Of cement concrete Etc As Reqd. , Fabrication, Supplying, Installation, Testing, Commissioning Of 12 Metres Semi High Mast System With Its Accessories, Mast Shaft Shall Be In One Section, Hot Dip Galvanized 4Mm Thick(Single Dip) Inside & Out Sides &Sultable For Wind Velocity As Per Is 875 Part3.There Shall Be In Longitudinal Seam Weld Per Section And No Circumferential Weld. It Should Also Included Accessories For Seml High Mast Head Frame,2 Point Suspension System,5 X 2.5 Sqmm Copper Conductor With Steel Wire Rope 5Mm Dia. (7/19 Construction) Single Drum Winch ,Galvanized Lantern Carriage Arrangement Suitable For 4/6 Nos. Flood Light Luminaries Symmetrically And Its Control Gears Boxes And Lighting Finial, The Mast Shall Have Integral Type Manual Tool Mounted At The Base Compartment Of Its Raising And Lowering Operation With Foundation Bolts And Anchor Plate And Control Panel Housing Suitable Reinforced Cement Concrete (1:2:4) Shallow Foundation Of Size 1M(L) X 1M Wide And 2M Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Reinforcement Of Cold Twisted Bars Of 12 Mm Dia -2100Mm Long (Approx.) 16 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia 3700 Mm (Approx.) 13 Nos. (With 150 Mm Spacing) As Required With Positioning Of Foundation Bolts And Providing Dwc Hdpe Pipe For Cable Entry & Exit As Required For The Semi High Mast Considering The Safe Soil Bearing Capacity At Site As 10T/Sqm At 2Mts. Depth With All Material I/C 4 Nos S.P Mcb,1 No. Double Pole 16Amp. Mcb Etc As Reqd. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is. , Providing And Fixing Name Board Made Of Ms Sheet 90X60cm, 1Mm Thick With Frame Of Ms Angle 50X50x6mm, Two Diagonal Braces At The Back Of The Sheet Of Ms Flat 40X6mm, Total Height Of The Board Above Ground Level 2.40M, Length Of Legs Below Ground 0.30M Embedded In Cement Concrete Block 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size) 30X30x45cm Including Excavation And Removal Of Surplus Earth With In 50M Lead, Applying Priming Coat Of Approved Steel Primer, Painting With Synthetic Enamel Paint Of Approved Quality And Lettering With Enamel Paint Of Approved Colour (One Side) As Per Drawing/Direction Of Engineer-In-Charge , Led Flood Light, Powder Coated Pressure Die Cast Aluminum (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip-66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 100W
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
42.
Power #11202992 Technical Bid
Tender for Summary Of Quoted Price (Schedule-A) Schedule Of Quantities And Prices For Design, Engineering, Supply Of Materials/ Equipments, Erection, Testing & Commissioning For Diversion Of 132 Kv Hatia - Ptps 8C & 9C Transmission Line On 220 Kv Multi Ckt. Tower From Location No. 115 To 400/220/132/33 Kv Gss Katia (Patratu) From Pvunl Premises And Dismantling Of Old Route (8C & 9C) Tower From Location No. 116 To 136 On Turnkey Basis. Tender Inviting Authority: General Manager, C&M (Nwbp), Jusnl, Ranchi Nit No. 805/Pr/ Jusnl/ 2025-26 Name Of Bidder Sl. No. Description Total Supply Inlcuding All Taxes Total Erection Inlcuding All Taxes Total , Design, Engineering, Supply Of Materials/ Equipments, Erection, Testing & Commissioning For Diversion Of 132 Kv Hatia - Ptps 8C & 9C Transmission Line On 220 Kv Multi Ckt. Tower From Location No. 115 To 400/220/132/33 Kv Gss Katia (Patratu) From Pvunl Premises And Dismantling Of Old Route (8C & 9C) Tower From Location No. 116 To 136 On Turnkey Basis. Schedule - A (Supply) Schedule Of Quantities And Prices For Design, Engineering, Supply Of Materials/ Equipments, Erection, Testing & Commissioning For Diversion Of 132 Kv Hatia - Ptps 8C & 9C Transmission Line On 220 Kv Multi Ckt. Tower From Location No. 115 To 400/220/132/33 Kv Gss Katia (Patratu) From Pvunl Premises And Dismantling Of Old Route (8C & 9C) Tower From Location No. 116 To 136 On Turnkey Basis. Tender Inviting Authority: General Manager, C&M (Nwbp), Jusnl, Ranchi Nit No. 805/Pr/ Jusnl/ 2025-26 Name Of Bidder Item No. Brief Description Of Work Unit Qty. Unit Supply Rate Including All Taxes & Levies Total Supply Item Cost Including All Taxes & Levies , Fabrication, Galvanizing And Supply Of Various Type Of Tower & Tower Parts, Tower Extensions (Complete) Excluding Bolts & Nuts, Step Bolts And Stubs But Including Hanger, D-Shackles Pack Washer Including Stub Etc. (I) Normal Tower (A) Ht Steel Mt 294.0 0.0 (B) Mild Steel Mt 290.0 0.0 , Fabrication, Galvanizing And Supply Of Stubs & Cleats For Various Type Of Tower , Tower Extensions (Complete) With Pack Washer, Excluding Bolts & Nuts. (I) Ht Steel Mt 27.8 0.0 (Ii) Mild Steel Mt 10.7 0.0 , Mono Pole Multi Circuit (I) D Type + 6 Meter Extension Set 2.0 0.0 (Ii) C Type + 3 Meter Extension Set 1.0 0.0 , Supply Of Bolts & Nuts Including Step Bolts And Spring Washer (I) Hexagonal Bolts And Nuts Including Step Bolts + Bolts And Nuts For Stubs Mt 16.0 0.0 , Earthing Of Tower (I) Pipe Type Earthing Nos. 28.0 0.0 , Tower Accessories (I) Danger Plate Nos. 28.0 0.0 (Ii) Number Plate Nos. 28.0 0.0 (Iii) Phase Plate (Set Of Three) Sets 112.0 0.0 (Iv) Circuit Plate (Set Of Two) Sets 56.0 0.0 (V) Anti-Climbing Device Nos. 28.0 0.0 (Vi) Bird Guard (Set Of Three) Sets 28.0 0.0 , Long Rod Insulators (I) Long Rod Polymer Insulator 70 Kn Of Light Weight Set 100.0 0.0 (Ii) Long Rod Polymer Insulator 90 Kn Of Light Weight Set 696.0 0.0 , Single Suspension I Hardware Fitting For Acsr Panther Conductor , Single Suspension Pilot Hardware Fitting For Acsr Panther Conductor , Single Tension Hardware Fitting For Acsr Panther , Double Tension Fittings For Acsr Panther , Supply Of Acsr Panther Conductor For 3 Phase Double Circuit Transmission Line , Gi Earth Wire (I) Gi (7/10) Swg Earth Wire Km 5.0 0.0 , Gi Earth Wire Accessories (I) Mid Span Compression Joint For Earthwire Nos. 20.0 0.0 (Ii) Flexible Copper Bonds For Earthwire Nos. 30.0 0.0 (Iii) Vibration Damper For Earthwire Nos. 60.0 0.0 (Iv) Suspension Clamp Assembly For Earthwire Set 15.0 0.0 (V) Tension Clamp Assembly For Earthwire Set 25.0 0.0 , Accessories For Acsr Conductor And Earth Wire (I) Mid Span Compression Joint For Acsr Panther Conductor Nos. 65.0 0.0 (Ii) Repair Sleeve For Acsr Panther Conductor Nos. 45.0 0.0 (Iii) Vibration Damper For Acsr Panther Conductor Nos. 700.0 0.0 (Iv) Vibration Damper For Opgw Nos. 60.0 0.0 (V) Joint Box For Opgw Nos. 4.0 0.0 Total Supply Cost 0.0 Schedule - A (Erection) Schedule Of Quantities And Prices For Design, Engineering, Supply Of Materials/ Equipments, Erection, Testing & Commissioning For Diversion Of 132 Kv Hatia - Ptps 8C & 9C Transmission Line On 220 Kv Multi Ckt. Tower From Location No. 115 To 400/220/132/33 Kv Gss Katia (Patratu) From Pvunl Premises And Dismantling Of Old Route (8C & 9C) Tower From Location No. 116 To 136 On Turnkey Basis. Tender Inviting Authority: General Manager, C&M (Nwbp), Jusnl, Ranchi Nit No. 805/Pr/ Jusnl/ 2025-26 Name Of Bidder Item No. Brief Description Of Work Unit Qty. Unit Erection Rate Including All Taxes & Levies Total Erection Item Cost Including All Taxes & Levies , Survey & Soil Investigation (I) Detailed Complete Survey Works Including Preliminary Survey, Profiling, Tower Spotting & Check Survey, Submission Of Survey Sheets Including Soil Investigations. Km 4.2 0.0 (Ii) Soil Investigation In All Kinds Of Soil Except Hr & Fr. Location 10.0 0.0 (Iii) Proto Assembly Charges For Narrow Multi Circuit Tower L.S. 3.0 0.0 , Work Associated With Tower Foundations (I) Excavation & Back Filling Of Excavated Soil For Foundation Works In Various Types Of Soils (B) Wet Soil Cum 1500.0 0.0 (E) Hard Rock Cum 200.0 0.0 , Pile Foundation Upto Ay Depth 1200 Sqmm With Bentonite And M25 , Ms Liner For Pile , Dismentalling Of Pile Cap , Centering Of Pile Cap, Tower Etc. , Concreting (Including All Associated Works Related To Foundation Not Covered In 4.1 & 4.3 (I) M 20 Nominal Concreate Mix 1:1.5:3 Cum 580.0 0.0 (Ii) M 10 Nominal Concreate Mix 1:3:6 Cum 90.0 0.0 , Supply And Placement Of Reinforcement Steel (Fe 500) , Installation Of Stub Including Bolts And Nuts , Erection Of Various Type Of Towers, Tower Parts And Tower Extension (Complete) With Bolts And Nuts, Including Tack Welding And Supply And Application Of Zinc Rixh Primer And Two Coats Of Enamel Paint And Tower Rectification (Cross Arm Change, Missing Psc And Band Pcs Change). (I) Normal Tower Mt 584.0 0.0 , Installation Of Earthing Of Tower (I) Pipe Type Earthing Nos. 28.0 0.0 , Installation Of The Followingtower Accessories (I) Danger Plate Nos. 28.0 0.0 (Ii) Number Plate Nos. 28.0 0.0 (Iii) Phase Plate (Set Of Three) Sets 112.0 0.0 (Iv) Circuit Plate (Set Of Two) Sets 56.0 0.0 (V) Anti-Climbing Device Nos. 28.0 0.0 (Vi) Bird Guard (Set Of Three) Sets 28.0 0.0 , Installation Of Insulator Strings Complete With Arcing Horns & Necessary Hardware, Installing & Stringing Of Conductor Including Fixing Of Conductor Accessories, Installlaing & Stringing Of Earthwire Including Fixing Of Earth Wire Accessories. (I) Normal Tower (A) Stringing Of Panther Conductor Multi Circuit 12 Ph Kms 4.2 0.0 (B) Stringing Of Opgw 48 Fiber With All Hardware. Kms 4.2 0.0 (C) Fixing Of Joint Box For Opgw. Set 4.0 0.0 , Right Of Way (The Rate Is Tentative, Payment Will Be Mabe Subject To The Production Of The Relevent Documents, Strictly As Per Actual) , Erection Of Mono Pole Multi Circuit. , Stringing Of Earthwire Complete In All Respect Including Transporation And Handing Over The Dismantled Materials To Jusnl Store. Annexure - C (Dismantling Of 8C & 9C Transmission Line From Location No. 116 To 136) , Dismentling Of Conductor & Earthwire/Opgw From Old Route Tower Line With All Accessories Complete (06 Nos. Of Panther Conductor). , Dismentling Of Old Route Tower Structure. , Transporation Of Dismentalled Conductor And Earthwire Through (One) Truck From Site To Transmission Central Store, Namkum Including Loading And Unloading, Stacking Etc. All Complete Job. (A) Transporation Of Equipments/ Materials By Small/ Medium Size Truck From Transmission Central Store Namkum And Other Gss/Sites Within 100 Km Radius. Trip 15.0 0.0 (B) Loading, Unloading And Stacking Of Conductor And Earthwire In Store. Mt 7.0 0.0 , Transporation Of Old Route Tower Structure Including Nuts, Bolts And Other Associated Materials At Site, Its Sorting, Stacking And Its Transport From Site To Central Store, Namkum All Complete Job. (A) Transporation Of Equipments/ Materials By Small/ Medium Size Truck From Transmission Central Store Namkum And Other Gss/Sites Within 100 Km Radius. Trip 40.0 0.0 (B) Loading At Site. Mt 160.0 0.0 (C) Unloading At Store Mt 160.0 0.0 Total Erection Cost 0.0
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
43.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
44.
Defence #11198549 AOC
Tender For Spl Repair To Certain Md Accn In Kandhar Line Under Ge Central Delhi Cantt-10; 1 Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc including remove alldebris at 2 KM away from site complete all as specified and directed. 2 M&L for 15 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces, applied in two layers i.e. 1st layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4 )mixed with WPCfinished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid separately) 3 M&L for rendering 10 mm thickin CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 4 M&L for rendering 5 mm thick in CM 1:3 on ceiling concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 5 M&L for preparation of new plaster surfaces of wall and applying water proof wall putty 1-2 mm thickness over plastered surfaces to prepare the surfaces even and smooth and finishing walls with Two coats @ 1.67 ltr/10 Sqm each acrylic smooth exterior paint of required shadeover and including priming coat of exterior primer @ 2.20 Kg/10Sqm complete all as specified and directed. 6 M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified and directed. 7 M&L for Preparation of new surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper complete all as specified and directed. 8 M&L for complete removal of existing treatment of old decorated plastered or unplastered surfaces of wall by rubbing , brooming down, washing with water etc and applying two coats of oil bond distemper complete all a specified and directed. 9 M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing tretament, by rubbing brooming down, washing with water etc and providing and applying 1-2 mm thickness wall putty over plastered surfaces to prepare the surface even and smooth and finishing wall surfaces by applying Two coats @ 1.67 ltr/10 Sqm each with acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg /10Sqm complete all as specified and directed. 10 M&L for dismantling water tanks of capacity exc 250 litres & n. exc 500 litres complete all as specified and directed. 11 M&L for rotational moulded polyethylene water storage tanks (ISI Marked) white colour 500 litres capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene ball complete all as specified and directed. 12 S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 13 S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 14 Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed. 15 Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) complete all as specified and directed. 16 Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting pointcomplete all as specified and directed. 17 M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone crushed aggregates) on roof padding, surface finished even and smooth without using extra cement complete all as specified and directed. 18 M&L for providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer or equivalent (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalentcomplete all as specified and as per manufacturers instructions. 19 M&L for providing and applying Smartcare Dampproof or equivalent, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per manufacturers instructions and all as specified & directed. 20 Supply only integral water proofing compound (ISI marked) complete all as specified and directed 21 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified and directed 22 M & L for brick work with Cement Mortar 1:6 using sub class B bricks, old size, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. 23 All As per item no 22 before but except bricks etc complete all as specified & directed 24 Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed. 25 Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 26 Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 27 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified & directed. (M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 28 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified & directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 29 S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (max toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr incharge. Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. 30 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 31 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately).Note: MTC and Screw Out Test shall be provided by Contractor 32 Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of density 650 kg/cbm manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws, etc. complete all as specified& directed.”Note: MTC and Screw Out Test shall be provided by Contractor 33 S&F Aluminium windowfor outer frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter(02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm ss 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. 34 S&F Aluminium windowOuter frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter (02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm SS 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. NOTE:- For installation of windows AC/desert cooler the provn of window glass shutter with wire mesh,grill and necessary fittings and locking arrangement for subject portion will be modified as per ground requirementt during execution as direction of Engg-in-Charge. 35 S&F ventilator outer frame 40mmx40mm with 1.3mm thickness, corner 45 degre cut & aluminum welded center mullion size 40mmx65mm also welded , fixed 5mm frosted glass EPDM rubber gasket with provision for fresh air fan, full system powder coating with pure polister coat of any shade install with SS screw rol plug pvc & silicone complete all as specified & directed 36 Dismantling of wall and ceiling/cupboard board fibre pulp AC boards etc any thickness including cover fillets removing the wiring complete all as specified & directed 37 S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmhaving good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws complete all as specified & directed. Material test certificate and authentication should be compulsory provided by the contractor. (For WC/Bathroom/Toilet/Kitchen and Cabinets) 38 S&F stainless steel continuous (Piano) hinges, bright finish, width of flap when open 30mm, complete all as specified & directed. 39 S&F of stainless steel handles 100 mm sizefor kitchen cabinet shutters and bed room cub boards complete all as per specified and directed. 40 S&F brass chromium plated tubular hanger rod 20 mm dia with suitable brackets complete all as specified and directed. 41 S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws complete all as specified & directed 42 S&F SS butt hinges medium weight 100mm size fixed with SS screws (ISI Marked) complete all as specified & directed 43 S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked) complete all as specified & directed 44 S&F 150mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked) complete all as specified & directed 45 S&F 300mm extruded section SS sliding door bolt with hasp and staple and fixing bolt and nut (ISI Marked) complete all as specified & directed 46 S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar complete all as specified & directed. 47 M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed 48 M&L for preparation of Old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed. 49 S&F for stainless steel plate rack of size 90x80x25 cm depth size made out of 1mm thick sheet complerte all as specified and directed. 50 S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complete all as specified and directed. 51 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm etc complete all as specified & directed 52 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm etc complete all as specified & directed 53 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 40mm etc complete all as specified & directed 54 Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as specified and directed 55 All as per item No. 54here in beforebut 20 mm dia complete all as specified and directed. 56 All as per item No. 54 here in beforebut 40 mm dia complete all as specified and directed. 57 S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed 58 Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for concealed water tubing etc cutting exceeding 10cm girth but not exc. 20 cm complete all as specified & directed. 59 Supply and fix in repairvitreous China wash hand basin (including pedestal)white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fitting and fixtures complete all as specified & directed 60 Supply and fix in repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe) complete all as specified and directed, 61 S&F in repair vitreous china wash down water closet EWC white/ ivory/off white (closedpattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flushpipe) complete in all respect complete all as specified & directed 62 Supply only PVC low level white flushing cistern valveless symphonic action type 5/10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified & directed 63 S&F in repairs 15 mm dia 600mm long PVC connectionswith brass check nut complete all as specified & directed 64 S&F in repairs Glass Corner Shelf 6mm thick including CP railing radius 250mm complete all as specified and directed by Engineer-in-Charge. 65 S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railingcomplete all as specified and directed by Engineer-in-Charge. 66 S&F in repairsHealth faucet, CP brass with 1.50m long flexible pipe complete all as specified and directed by Engineer-in-Charge. 67 S&F fancy type brass chromium plated toilet paper holder, complete all as specified & directed 68 S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Make-Jaquar/marc/Kohlar, complete all as specified & directed 69 S&Fin repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 70 S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 71 S&Ffor 15 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 72 S&Ffor 20 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 73 S & F in repairs Chromium plated brass overhead shower with arm complete all as specified and directed. 74 S&F in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 75 S&F in repairs Brass chromium plated mode 2 in 1 WHB mixture model Quarter half turn (SOLO) omplete all as specified & directed. 76 S&F in repairs brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) complete all as specified & directed 77 S&F in repairs Brass chromium plated mode 2 in 1 sink mixturemodel Quarterhalf turn (SOLO) ofas complete all as specified & directed. 78 S&F in repairs chromium plated soap dish fancy type complete all as specified & directed 79 S & F in repairtowel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embedded in cement mortar 1:3 with MS screws etc complete all as specified and directed. 80 Dismantling of floor of size not exceeding 4.00 Sqm each for EWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) The area of Each WC portion is n.exc 4.00Sqm each.(g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 81 Dismantling of floor of size not exc 1.50 Sqm for IWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 82 Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. 83 M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqmbut not exceeding 0.11 sqmas in floors over and including 15mm thick screed bedin cement mortar 1:4 set and jointedin neat cement slurry and pointed in coloured cement. complete all as specified and directed 84 S&F for glazed Ceramic tiles 9 to 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.. 85 All as per item no. 84 here in before but on vertical surfaces as in skirting etc over and including 10mm thick screed bed in CM 1:3, set and jointed in white cement with pigment to match all as specified and directed. 86 M&L glazed ceramic coloured tiles in vertical surface600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 10mm thick in CM (1:3) complete allas specified & directed. 87 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc incl brushing neat cement slurry with 3.0kg of cement per sqmtr complete all as specified and directed. 88 M&L for Granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms with necessary hole for gas pipe where ever required and likes over and including cement mortar bedding of 20 mm thick in CM 1:4 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed. 89 M&L for machine cut kota stone slab flooring, and (one Pieces) as in tread, riser, landing, 20-25 mm thick over and including cement screed bed 20mm thick in CM 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. 90 M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part ofsand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete all as specified and directed Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. 91 M&L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water.All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint complete all as specified and directed. 92 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 93 M&L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth without using extra cement, complete all as specified and directed 94 M&L for 40 mm thick cement concrete 1:2:4type B0(using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fairusing extra cement, complete all as specified and directed 95 Demolition of reinforced cement concrete in any position complete all as specified and directed 96 M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone crushed graded aggregate) as in louvers and jallies 25mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 all as per sample shown complete all as specified and directed 97 M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone crushed aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed. 98 Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed. 99 S&F TMTmild steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed. 100 Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter including bends complete all as specified and directed . 101 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete all as specified and directed . 102 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete all as specified and directed 103 S&F for PVC (SWR) bends & tee any radius, 110 mm bore complete all as specified and directed. 104 S&F for PVC (SWR) bends & tee any radius, 75 mm bore complete all as specified and directed. 105 S&F for PVC (SWR) door plates , Yjunction 110 mm bore complete all as specified and directed. 106 S&F for PVC (SWR) door plates ,T junction 110 mm bore complete all as specified and directed. 107 S&F for 100 PVC (SWR) bends with door plate& teecomplete all as specified anddirected. 108 S&F for 75 mm PVC (SWR) bends with door plate & tee complete all as specified anddirected. 109 S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified anddirected. 110 S&F in repair 20 mm nominal dia and minimum thickness 1.2mm of SS-304 Grade of Stainless Steel tubefor curtain rod including pair of suitable S.S brackets approved by GE including taking down old pelmet boxes with curtain rods complete all as specified and directed. 111 Dismantling wrought iron or mild steel work of any description not otherwise provided for parapet railing, balconies, tank staging, metre rooms shaft areaany descriptioncompleteas specified and directed. 112 Supply and fix welded steel wire fabric(MS Jali) fixed to steel members weight n. exc. 4 kg/sqm including welding complete all as specified and directed. 113 S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed 114 Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt complete all as specified and directed 115 S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge 116 S&F in repairs two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge. 117 ROAD, PATH AND CULVERT 118 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 119 M&Lfor 75 mm thick PCCtype D-2 1:4:8 (40mm graded aggreate) as sub-base complete all as specified and directed 120 S&F Endura colour paving tiles 30cm X 30cm x 15-20mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. 121 M&L for Providing PCC in coping type B-1, 1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified and directed 122 M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed 123 SEWAGE DISPOSAL 124 Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loosesoil complete all as specified and directed 125 Returningfilling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed 126 Removing excavated materials to a distance exc 1.50 Km but not exc 5 Km outside defence land and depositing where directed complete all as specified and directed 127 M&L for PCC 1 : 4 : 8 type D2 using 40mm graded stone crushed aggregates as in foundation of manholes, posts etc completeall as specified and directed. 128 M&L for PCC 1 : 2 : 4 type B1 using 20mm graded stone crushed aggregates as in surfaces channels and drains complete all as specified and directed. 129 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stoped ends etc complete all as specified and directed. 130 S&F DWCPE(SN8) 150mm dia (Internal Dia)pipes, snap fit coupler and rubber ring including testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified and directed. 131 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified & directed 132 M&L for Brick work with sub class ‘B’ bricks straight or curved on plan, built in cement mortar 1:4 using old size bricks complete all as specified and directed. 133 All as per item no 130 here-in-above but except bricks 134 M&L for PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Itemwater troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. 135 M&L for precast factory made manhole cover, area of each cover n.exc 0.60 Sqm, 100mm thick with SFRCconcretingincluding grove and hook arrangement for lifting and placing in position and sides covered by MS sheet complete all as specified and directed. 136 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100mm internal dia pipe, complete all as specified. 137 M&L for rendering 15mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound @ 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately. 138 Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm diapipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge 139 INTERNAL ELECTRIFICATION 140 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc 141 Taking down old MCCB , TPN DBs , SPN DBs (incl MCB SPN & SP) & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. 142 Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. 143 Disconnecting elect connection and taking down of ceiling fan/ Exhaust fanof any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge. 144 M&L for point wiring complete with 1.5 Sqm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit of 20 mm nominal diaand conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and including provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel concealed in walls, with modular sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and directed for the following:- 145 One light /Ceiling fan/exhaust fan point controlled by one switch. 146 One light point controlled by two, two way switch ( switch to be measured and paid separtely) 147 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. 148 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board 149 One bell point controlled by one bell push. 150 All as per item Ser No 142 here-in-before but point wiring with 2.5 sqmm single core FRLS 1100 Volts in New PVC concealed conduitmedium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 2.5 sqmm single core FRLS 1100 Volts copper conductor cableas earth continuityconnected to common earthfor one 15 A switch socket power point, complete all as specified and directed 151 M&L for submain wiring 4 Sqmm nominal cross sectional area,two single core, 1100 Volts grade, multi-stranded, PVC insulated unsheathed, FRLSHcopper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of suitable dia, medium grade with all conduit accessories and connected to common earth dolly to suitable copper lugs including all cutting/chases etc in walls and making good to the disturbed surfaces to match the existingsurfaces.Note:- Three run of single core wire andone run of conduit shall be measured and paid as one unit complete all as specified and directed 152 All as per item ser No 144 here-in-before but for 02 x 6 Sqmm for phase & neutral and 01 x 6 Sqmm for continuousearth wire concealed/surface 153 M&L for switch Modular type 6 Amp one wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 573400 / Schnider Cat No X1001WH / Wipro Cat No RF 110 154 M&L for switch Modular type 6 Amptwo wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 2573402/ Schnider Cat No X1002WH/Wipro Cat No RF 210 155 M&L for switch Modular type type 16 Ampone way,ISI marked complete all as specified and directedMake : Legrand Cat Part No 573410/ Schnider Cat No X11001WH/Wipro Cat No RF 130 156 M&L for Modular type socket outlet 2 in 1, 5 pin 6 Amp ,ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573424/ /Schnider Cat No X2005WHNS/Wipro Cat No R 1212 157 M&L for Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573471/ Schnider Cat No X2106WH/ Wipro Cat No R 1332P 158 M&L for ceiling rose 3 phase PVCpolycorbonate,isolated body, complete all as specified and directed 159 M&L for bell push,modular type, 6 Amp, 1 moduleISI marked complete all as specified and directed.Make : Legrand Cat Part No 573413/ Schnider Cat No X1005WH/ equivalent in Wipro 160 M&L for bell ding dong AC, 230 volts, single pole complete all as specified and directed. 161 M&L for angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified anddirected. 162 S&F LED bulb 12 watts, 1200 lumens output, 6500K suitable for B-22 base complete all as specified and directed. 163 M&L for earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to GI wire 4.0 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze drilled and screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised wire and protection light grade GI pipe upto 7.5 mtr, excavation, etc shall be deemed to be in the quoted rates. 164 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 08 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 165 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 12 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 166 S&FMCB confirming to ISI/IEC -60898-1 (2002), SPN, AC, 240 volts, of 40Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 167 S&FMCB confirming to ISI/IEC -60898-1 (2002), SP, AC, 240 volts, of 6-32Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 168 Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 120 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. 169 S&F in replacement of LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 140 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. 170 M&L for in replacement Decorative wall mounting CITY-1 Decorative wall light fixture made up of Polycarbonate,Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 Including 12 W retrofit LED BULB (B-22 base). NOTE- one piece of LED bulb 12 watts included with city -1 fitting complete all as specified and directed. 171 Supply and fix in replacement 10 watts bulkhead fitting, IK 09 with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover,including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. 172 Taking down existing electric meter & refixing the same after completion of job with electric connection by 8 way DB in good way by cleaning and qtr No. marking complete all as specified and directed.. 173 Supply and fixingexhaust fansmetal body AC single phase 230/240 V of size300 mm sweep, Air flow rate > 900cum/min, Bird screen forprotectionagainst birds, double ball bearing, metal body with louvre also with louvre for fixing of exhaust fan complete all as specified and directed. 174 Supply and fixing new BLDC fan against old ceiling fans BLDC conversionthree blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5star rating for energy saving, rated Air delivery >220 cum/min,AC single phase 230/240 V of size 1200 mm sweep including fan regulators,down rod, canopy & all accessories including making connection with three core flexible, copper winding in fan,copper cable pvc insulated of suitable length, complete all as specified and directed. NoteBLDC Fan should work onelectronic fan regulator & also with remote controled. 175 S&F modular type sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall complete all as specified and directed. 176 S&F of water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity25 Ltrs, having heating element 1.5 KW and not less than 5 star rating,suitable for ,230 volt,50 Hz electric supply complete all as specified and directed . 177 S&F fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed. 178 S&F in replacement pressure die cast aluminium housing LED street light luminaires with IP-66 deg. of protection suitable for 35 watt LED fitting, Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 duly fixed on 25 mm dia GI pipe light grade including 40 X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : Quoted rates shall be inclusive of all accessories like suitable GI pipe, 40x6 mm thick MS flat, fastner, nut & bolts, suitable length of flexiable wire etc. 179 S&F in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-43 protection), mechanical impactstrength IK - 09, with cement spill protector double doorfabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 125/160 Amp as incomer and12 Nos of SP MCB 10 to 63 Amps outgoing and conforming to HSN code : 8537 complete all as specified and directed. Note :- MCCB & MCB will be measured & paid separately. 180 S&F in replacement MCCB 125 Amps, thermal magnetic release,4 pole 16 kA ICS=ICU Complete all as specified and directed.
Contract Date: May 30, 2026 Contract Value : 3.02 Crore
Statutory Bodies & Commissions/Committees No of Bidders 11
45.
Defence #11191790 Price Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Any Guage, Thickness, Including Nainital Pattern Or Similar Pattern Roof Covering Complete All As Specified And Directed. , S&F 0.63Mm Thick Galvanised Corrugated Ms Sheeting (Cgi Sheet Roofing) With Two Corrugation Side Laps, With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusive Fixed With Coach Screws And Washers As In Roofs Etc All As Specified , S&F 0.63Mm Thick Plain Galvanised Ms Sheeting Using Grade-O Sheets With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusives, As In Roof, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Complete All As Specified And Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa (Az 150) As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , Demolition Of Brick Work Or Stone Masonry Precast Plain Cement Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6 All As Specified And Directed. , M&L For Precast Cement Concrete Block Masonery With Solid Block Of Cement Concrete 1:3:6 Type C-1 ( Using 20 Mm Graded Stone Aggregate) Exc 10 Cm In Width And Setting In Cm 1:6Complete All As Specified And Directed By Engg-In- Charge , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls By Adding 17-19% Of Potable Water By Weight Of Material For Thickness Above 15Mm It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days 10-12 Mpa/Bulk Density 1500-1600 Kg/M3. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 20 Mtr Ht All As Specified And Directed) , M&L For Applying Two Coats Of Cement Base Paint Over A Coat Of Primer On Newly Plastered Surfaces Of Walls Including Preparation Of Surfaces Complete. , (M&L For Preparation Of New Plastered Surfaces & Applying A Layer Of Birla Putty 3Mm Thickness On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Distemper Complete All As Specified And Directed. , (M&L Three Coats Of White Wash On Walls Including All Preparation Complete , M&L Preparation Of Old Surfaces Including Cornices Etc And One Coat Of Oil Bound Distemper Complete All As Specified And Directed. , M&L For Preparation Of Old Plastered Surfaces & Applying A Layer Of Birla Putty On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Paint Complete All As Specified And Directed. , Dismantling Of Ceiling Board (Flbre Pulp, Insulation Etc) Or Insulation Boards/Slabs/Blankets Any Thickness, Including Cover Fillets Complete All As Specified And Directed. , S&F Of Powder Coated Grid Frame Work For False Celling Comprising Of The Following Sections For Making Partitions Of 600X600 Mm Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including 4Mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mmx24mmx0.3Mm Thick , Cross Tee Shall Be 28Mmx24mmx0.3Mm Thick And Wall Angle Shall Be 24Mmx24mmx0.3 Mm Thick Incl 4 Mm Thick E-Board Classic (Make-Everest) For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface Complete All As Specified And Directed.Complete All As Specified And Directed , S&F Solid Pvc Wall Lining Dual Colour Consisting Of 5 Mm Thick Wood Grain Printed Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specification And Drawing Complete Fixing Arrangement Icluding Taking Down Old Existing Wooden Panelling Complete. , S & F For 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc 15Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , M&L For Cement Concrete 1:4:8 Type D-2 (Using 20Mm Graded Stone Agg) As In Foundation , Filling And Mass Concrete Complete All As Specified And Directed. , M&L 40 Mm Thick Plain Cement Concrete Type B-1 (1:2:4) Using 20 Mm Graded Stone Aggregate As In Flooring Finishing Cement Concrete Even And Smooth With Using Extra Cement Complete All As Spd , Surface Channel In Concrete 1:3:6 (40 Mm Graded Aggregate) For Drain Complete All As Specified And Directed. , Extra For Forming Fair Finished Drain Or Channel 30 Cm Inner Girth In Cement Complete All As Pecified And Directed. Concrete, Using Ex- Tra Cement, Including Forms, Moulds, Mi- Tred/Stopped Ends Etc.All As Specified And Directed. , M&L For 75Mm Thick Cement Concrete 1:3:6 Type C-2 (Using 40Mm Graded Stone Agg) As In Plinth Protection Laid To Slope In Bays And Finishing The Surfaces Of Concrete Topping Fair And Even And Exposed Edges Fair Or Rounding Or Chamfering Laid In Panels Wit , M&L Chequred Tiles 300 X 300 X 25 Mm Coloured Glossy Finish Rubber Pressed Moulded Of Approved Pattern & Shade Make As Approved By Ge As In Floor Over 15 Mm Thick Screed Bed Or Bedding Layer In Cm(1:4) And Jointed Complete All As Specified And Directed. , M&L Interlocking Tiles 75-80 Mm Coloured Rubber Pressed Glossy Finish Thick Of Approved Pattern & Shade Isi Marked Or Approved By Ge Set Jointed Over 40 Mm Th Fine Sand Cushion Including Sides Are Tappered 75 Mm In Width By Plain Cement Concrete 1:3:6 Type C1 (Using 20Mm Graded Crushed Stone Agg.) Complete All As Specified And Directed. , Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. , Dismantling Of Timber Scantling 40 Sqcm And Over In Section In Any Position As In Framed Work Complete All As Specified And Directed , M&L For 2Nd Class Hard Wood Clean Sawn In As In Scantling Framed And Over 40Sqcm Fixed With Screws Etc All As Specified And Directed. , S&F 18Mm Thick Mdf Board Both Side Finished As In Wardrobe/ Cup Board Shutter All As Specified And As Directed By Engineer-In-Charge. , Dismantling Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors Laid Bedded And Pointed In Any Mortar, Aprons Etc. , M&L Plain Cement Concrete 1:5:10 Type E2 Using 40Mm Graded Aggregate As In Sub Base Complete All As Spd , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. , M&L 300X450x7mm Thick Glazed Ceramic Digital Tiles Coloured Incl , Design And Pattern As Approved Fixed As In Vertical Surface Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Cement With Colour Pigment To Match Incl Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Complete All As Specified And Directed. , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.11 Sqm But N.Exc. 0.18 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigment Incl 15Mm Thick Screed Bed In Cm 1:6 Complete All As Spd , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.18 Sqm But N. Exc. 0.38 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigments Incl 15Mm Thick Screed Bed In Cm 1:6Complete All As Spd , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.18 Sqm But N. Exc. 0.38 Sqm In Skirting /Dado Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigments Incl Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Complete All As Specified And Directed.Complete All As Spd , M&L 18 To 20 Mm Thick Granite Stone On Steps Including Rubbing And Polishing And Making Hole For Gas Pipe And Front Portion Rounded And Chamfered Complete Including Screed Bedding 15 Mm Thick In Cm 1:4 Complete All As Spd , S&F In Repairs Parquet Flooring 8.3 Mm Thick Hard Board Plank Both Side Laminated With Decorative Surface And Approved By Ge Laid Above The Thermoplastic Sheet Complete All As Spd , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , M&L For 15Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , M&L For 20 Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Bib Tap Long Body Cp, Screwed For Iron Pipes Complete All As Specified And Directed , S&F Angle Cock 15 Mm Bore Brass Chromium Plated, Screwed Both Ends For Pipes Or For Unions Fixed In Repairs Including Making Good To Match With Existing Surface , S&F In Repair Pillar Taps 15 Mm Bore, Brass Chromium Plated , Screwed Down High Pressure With Or Without Letter Hot Or Cold With Long Screwed Shanks And Fly Nut Complete All As Specified, Fixed In Repairs. , S&F Bib Tap Standard Of Ptmt (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath Fitting), Any Colour, Screwed Foriron Pipe 15 Mm Bore Pipe (Minimum Weight 90 Gm) All As Specified, Fixed In Repairs (Make : Prayag Or Equivelent As Approved) , S&F In Repair Polymer White (Polypropeylene Delrin And Abs) Low Level Flushing Cistern 10 Ltrs Capacity, Valveless, Syphonic Action Type Complete With Inlet, Ball Valve Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete, Complete All As Specified And Directed. , S&F In Repairs, 550X400mm Vitreous China, Wash Hand Basin , Flat Back With Pedestal Excluding Trap And Waste Chain And Plug And Porcelain Stopper Including Sutaible Size Brackets Waste Pipe And Waste Coupling Complete All As Specified And Directed. , S&F Vitreous China Squatting Pan Orrissa Pattern Size 580 X 440 Mm White With Intregal Foot Rests, With & Including P Or S Trap (Excluding Material & Labour Of Flushing Cistern And Flush Pipe) Including Conection To Trap And To Flush Pipe Etc Complete Including Making Good To Floor Complete All As Specified And Directed Fixed In Repairs. , Dismantling Water Tanks 500 Ltrs Capacity Complete All As Specified And Directed. , Dismantling Water Tanks Of Any Description, Capacity Exceeding 500 Litres But Not Exceeding1000 Liters Complete , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Make - Prayag Complete All As Specified And Directed. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Make - Prayag Complete All As Specified And Directed. , S&F 20 Mm Dia Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Road & High Density Plastic Ball Screwed For Iron Pipe And Fixed In Repairs (Min Weight 210 Gm). , S&F 15 Mm Dia Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Road & High Density Plastic Ball Screwed For Iron Pipe And Fixed In Repairs (Min Weight 210 Gm). , S&F Pvc Circular Top Cover Suitable To Rotational Moulded Polyethylene Water Storage Tanks Of 500 /1000 Litres Capacity Tanks Of Standard Mares, With 6 Mm Dia Nut And Bolts On Two Ends Of Cover To Act As Hinge As Will As Locking Arrangement For Side Opening , S&F In Repairs Sinks With Drainage Board Made Of Stainless Steel 1Mm Thick Kitchen Or Laboratory With Plugs,Washers And Wastes,Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cautilever Brack Etc And Connecting Union To Pipe Over All Size 915Mmx460mm Bowl Size 405Mm X 354Mm X 178Mm As Approved By Gecomplete All As Specified And Directed. , S&F Pvc Whb Waste Pipe 32/40 Mm Dia Compolete All As Spd , S & F In Repairs 15 Mm Bore Fancy Type Chromium Plated Wall Mixer With Provision For Overhead Shower With 115Mm Long Bend Pipe On Upper Side, Connecting Legs And Wall Flanges, Screwed Down High Pressure With Or Without Lettered Hot And Cold Screwed For Iron Pipe Complete All As Specified And Directed. , S&F, 5.50 Mm Thick Looking Mirror Of Selected Quality Glass, Size 60 Cm X 45 Cm, Mounted On 6Mm Thick Commercial Plywood And Fixed To Wooden Plug With C.P. Brass Screws And Cup Washers With & Including Plastic Fancy Frame Alround All As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Not Exc 1.5 Sqm Each.& Removing To Or From Store All As Specifed & Directed. , Taking Down Chowkats Or Frames Exc 1.5 Sqm But Not Exc 4 Sqm Each With Shutters (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , M&L For Second Class Hard Wood Plain, Solid, Straight Chowkats And Frames, Wrought, Frame Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed. , S&F Factory Made 35Mm Thick Plain Framed, Panelled Shutter (Two Panel) With Lock Rail And Panel Of 9 Mm B.W.P. Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is : 1003 (Part I), Kiln Seasoned And Chemically Pressure Treated All As Specified , S & F 35 Mm Thick Second Class Hard Wood Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc., Rs, Edges Of Framing Plain, Chamfered Complete All As Specified And Directed. , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/ Window/ Ceosetory Window & Other Frames/ Chowkhat Of Size 45 X 70 Mm Comprising Of Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wwod Powder/ Rick Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Stat Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modules Of Elasticity 900 N / Mm 2 And Resistance To Spread Of Flame Of Class A Catogory With Property Of Being Termite/ Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With Ms Hold Fast/Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge (M.S. Hold Fast/ Lugs Or Ss Dash Fasteners Shall Be Paid For Separately). , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Plain Flush Door Shutter Of 35 Mm Thick Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/ Cum And Screw Withdrwal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N Mm2 Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Catogary With Property Of Being Termite/ Borer Proof, Water/ Moisture Proof And Fire Retardanat And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws, All As Per Direction Of Engineer-In-Charge (Note:- Stainless Steel Butt Hinges And Necessary Ss Screws Shall Be Paid Separately. , S&F Aluminium Powder Coated Door With Shutter And Frame Of Aluminium Section Sliding Type As Per Following Specifications With And Including Round Type Aluminium Handle, Tower Bolts, Hinges, Panes Etc And As Directed At Site. Make Jindal Or Its Equivalent Approved Make:- (A) Door Frame : 100 X 44 X1.6 Mm Section For Complete Frame. (B) Door Shutter : Top & Bottom Rail Of 100X44x1.6 Mm, Middle Rail Of 83 X 44 X 1.6Mm, Both Styles Of 83 X 44 X 1.6 Mm Size Shall Be Used. (C) Glass Pane : 5Mm Thick Sun Broken Glass Fixed With Gasket With Aluminium Clip , Jointing Clips, Glazing Clips, Rubber Packing, Screws Etc. (D) Jointing Cleats, Glazing Clips, Rubber Packing, Anodized Aluminium Snap Beading, Screws, Anodized Aluminium Fittings Such As 100Mm Long 03 Nos. Hinges, Aluminium Handles , Aluminium Tower Bolts ,And Mortice Lock 6 Levers Etc Complete All As Specified And Directed , M&L For Taking Down Existing Aluminium Door Shutter Carefully Without Damage Of Glass Panesincluding Replacing Aluminium Clip , Jointing Clips, Glazing Clips, Rubber Packing, Screws Etc As Reqd At Site And Refixing The Same After Complete Repairs All As Specified And Directed ( Note- Any Replacement Of Aluminium Rails Or Stiles If Reqd To Be Replaced Will Be Measured Seperately ) , S&F In Repairs Double Action Floor Spring Hydraulicaly Regulated Made Up Of Minimum 1.25Mm Thick Aluminium Alloy Sheet Foundation Box Main Body With Stainless Steel Cover Governing Pivot Made Brass Other Parts Made Of Mild Steel Heavy Duty And Fixed Complete All Specified , S&F Aluminium Partition Powder Coated Of Frame Of Aluminium Section 44.45 X 44.45 X 1.6Mm Etc And 5 Mm Thick Sun Broken Glass Fixed With Gasket With Aluminium Clip , Jointing Clips, Glazing Clips, Rubber Packing, Screws Etc.And As Directed At Site. Make Jindal Or Its Equivalent Approved Make Including Taking Down Old Userviceable Wooden Partition Completeall As Spd , S&F 100Mm Size Ms Butt Hinges, Medium Weight, Cold Rolled And Fixed Complete All As Specified And Directed. , S&F 150Mm Long Aluminium Tower Bolt And Fixed Complete All As Specified And Directed. , S&F 125 Mm Size Aluminium Handle Plate Type Anodised Complete All As Specified And Directed. , S&F In Repairs Hydraulic Door Closer Aluminium ( Die Cast) Regulated Designation No-3 Universal Type For Door Shutter Complete All As Spd , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 3 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F In Repairs Of Galvanised Mild Steel Wire Cloth 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.18Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples Complete All As Specified And Directed. , M&L For Preparation Of New Or Previously Untreated Wooden Surfaces Of Any Description,Not Otherwise Described Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Fixing Of Hold Fast, Bed Blocks Etc Including Necessary Form Work As Required Complete All As Specified And Directed. , Demolition And Breaking Up Drains Pipes(150Mm Size) Salt Glazed Ware, Ac Or Reinforced Concrete Set In Cement Mortar Complete All As Specified And Directed. , S&F 110Mm Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Wall And In Floors Complete All As Specified And Directed , S&F Of 75 Mm Bore Pvc (Swr) Pipe Single Socketed In As Length With Rubber Ring As In Vent Pipe Complete All As Specified And Directed , S&F In Repairs Of 110 Mm Dia Pvc (Swr) Bend Complete All As Specified And Directed. , S&F In Repairs Of 75 Mm Dia Pvc (Swr) Bend Complete All As Specified And Directed. , S&F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D; Type, 60 Cm Long Between Flanges Complete All As Specified And Directed. , S&F Chromium Plated Soap Disk Fixed To Plug With Chormium Plated Brass Screws All As Specified And Directed , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified. , S&F Mild Steel Work As Hold Fasts, Bands, Straps, Supports Or Stays For Pipes Eaves Gutter Including Bolts If Required, Hooks (Stay), Clamps And Similar Small Articles, Conforming Tofe 310-0 Or Fe 410-0 Complete All As Specified And Directed. , Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For. , S&F Mild Steel Framed Work Such As Purlin , Truss, Square Tube , Ms Pole , Grating Etc With End Of Bars Shouldered And/ Or Riveted Or Forged Into Spikes, Framed Guard Bars, Barred Iron Doors, Ladders, Framed Balusters, Walk Ways, Railings, Welded Wire Mesh And Similar Work Confirming To Fe-290 Gde E-165 Complete All As Specified And Directed. , M&L For Preparation Of Old Or Previously Treated Wooden Surfaces Of Any Description,Not Otherwise Descri- Bed Over 10Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paint Complete All As Specified And Directed.. The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , S& F In Repair Vitreous China Premium/ 1St Quality Wash Down Water Closet Wall Hung Ewc White/ Ivory/Off White (Closed Pattern Incl All Necessary Accessories Like Rag Bolts/ Gel Gasket Etc. (Excluding Flushing Cistern & Flush Pipe) Complete In All Respect All As Specified. , Health Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Uttarakhand View Result →
46.
Defence #11191788 Price Bid
Tender for Taking Down Chowkats Or Frames N.Exc 1.50 Sqm Each, Without Taking Off Shutters From The Frames Including Iron Mongry. , Taking Down Of Shutters Of Any Description Of Area Exc 1.00 Sqm But N. Exc 2.00 Sqm Each , S&F 35 Mm Thick Glazed And Skeleton Shutters 2Nd Class Hard Wood, Open Rebated And Prepared To Receive Glass, Gauze, Etc. (Without Sash Bars), Edges Of Framing Plain, Chamfered Or Rounded. Fitted With Cut And Mitred Beads For Securing Glass, Etc.; Sizes Of Me-Mbers Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A); Supplied And Fitted To Chowkats , S & F Plain, Framed, Panelled Shutters 35 Mm Thick In 2Nd Class Hard Wood (Any Number Of Panels), With Panels Of Timber Flat On Both Sides (Feather Edged), Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers: Supplied And Fitted To Chowkats , S&F Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/ Window/ Ceosetory Window & Other Frames/ Chowkhat Of Size 45 X 70 Mm Comprising Of Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wwod Powder/ Rick Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Stat Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modules Of Elasticity 900 N / Mm 2 And Resistance To Spread Of Flame Of Class A Catogory With Property Of Being Termite/ Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With Ms Hold Fast/Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge (M.S. Hold Fast/ Lugs Or Ss Dash Fasteners Shall Be Paid For Separately). Note:- For Wpc Solid Door/Window Frames, Minus 5Mm Tolerance In Dimension I.E. Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made. , S&F Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Plain Flush Door Shutter Of 30 Mm Thick Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/ Cum And Screw Withdrwal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N Mm2 Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Catogary With Property Of Being Termite/ Borer Proof, Water/ Moisture Proof And Fire Retardanat And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws, All As Per Direction Of Engineer-In-Charge , S & F Butt Hinges, Medium Weight Cold Rolled 100Mm Size, Complete. , S&F 150Mm Long Aluminium Anodized, Barrel Tower Bolt Of Extruded Section Complete. , S&F 200Mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy All As Specified. , S&F Anodised Aluminium Alloy Handles Cast Type, Each 150Mm Long , Dismantling Of Wall And Ceiling Boards (Fiber, Pulp, Insulation Etc,) Or Insulation Boards/Slabs/Blankets, Any Thickness Including Cover Fillet Complete All As Specified And Directed. , S&F Powder Coated Aluminium Anodised Snap Grid System Of Grid Size 600 X 600 Mm Fixed To Walls With Rawl Plugs And Screws And Hang To Roof Members With 2 Mm Dia Gi Wire Comprising Of The Main Tee 28X24x3mm Thick, Cross Tee 28X24x3mm Thick And Wall Angle 24X24x3mm Thick Sections Complete All As Specified And Directed. , S&F 4 Mm Thick Everest Designer Ceiling (E-Board Classic) Board / Tiles For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Gi/Aluminium Snap Grid As In Ceiling With And Including Dusting Of Surface And Applying Two Coats Of Oil Bond Distemper Over A Coat Of Primer Complete All As Specified And Directed , S&F 6Mm Thick Decorative Pvc Sheet Hollow (Design Approved By Ge) For Insulation And Acoustic Purpose On Wall/Ceiling Surface, Screw To Timber Frame Work For Levelling Of Wall As Reqd, Including With Panelling To Vertical Surfaces, Fixed With Rawl Plug And Screws Complete All As Specified And Directed , Dismantling Laid Dry Or Laid Dry And Pointed Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc. , M & L Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over And Including Cement Screed Base 20Mm Thick In Cement Mortar 1:6, Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified And Directed. , Kota Stone Slab 20-25Mm Thick In Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including 15Mm Thick Rendering In Cm 1:3 Including Rubbing And Polishing. , S&F In Repairs 600 Mm X 450 Mm Beveled Edge Mirror Of Selected Quality Glass 5.5Mm Thick Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood & Fixed With Wooden Plugs With Chromium Plated Brass Screws And Washer And Aluminum Beading Complete All As Directed. , S & F In Repairs, Aluminum Die Cast Body Door Closer Hydrau Lically Regulated, Designation No. 3, Universal Type, Suitable For Door Shutters Of 851 To 1000 Mm In Width And Of Weight Between 61 To 80 Kg And Fixed Complete. , M&L For Preparation Of Old Painted Wooden Surfaces Of Any Description Over 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint ,Complete All As Spd And Directed. , S & F 5.50Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.50 Sqm In Each Pane With Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden Frames Or Stone, Concrete Or Brick Surrounds, Glazed With Putty Or Fixed With Beadsall As Specified And As Directed. , S&F In Repair, Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples, All As Specified And Directed. , S&F In Repairs Of 20Mm Dia Harrison Rails, Mild Steel, Chromium Plated With Fixing Brackets, Stops, Rollers Etc. , S&F In Repairs Tubular Towel Rail Brass Chromium Plated 20Mm Dia D Type 60Cm Long Complete All As Directed. , S&F In Repair, 1000 Ltrs Capacity White Colour Three Layer Rotational Moulded Polythene Water Storage Tank (Cylinderical Vertical With Closed Top) Hoisted And Fixed In Position With 20Mm Bore Dia Ball Vallves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe And Fixed, (Minimum Weight 20 Mm- 210 Gms/ 25Mm-455Gms/ 40Mm - 690 Gms) , All As Specified In Ssr Part-I, Complete Including Dismantling Of Existing Tank. , S&F In Repair 10 Ltr Capacity Pvc Valveless,Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet Ball Valve , Float And Handle Including Brackets, Complete All As Specified And Directed. , M&L For Sunken Floor Treatment As Under:- (I) The Sunken Portion Shall Be Tested For Leakage / Seepage / Dampness By Ponding With Water For 72 Hours. In Case Any Defect Is Noticed, The Defective Portion Shall Be Grouted With Cement Slurry Mixed With Suitable Chemical & Tested Again. The Process Of Grouting And Testing Shall Be Repeated Till Leakage/ Seepage/ Dampness Is Eliminated. (Ii) Demolition Of Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For In Any Type Of Filling In Sunken Portion & Cleaned The Sunken Potion Including Vertical Wall Surface Complete All As Directed. (Iii)Laying Of 40Mm Thick (Min) Plain Cement Concrete (1:2:4) Type B-0 Using 12.5 Mm Graded Stone Aggregate With Integral Water Proofing Compound As Per Manufacturer Instructions On Bottom Of Sunken Portion With Proper Slope Towards Spout. Vertical Sides Shall Be Plastered In Cm (1:3), 15 Mm Thick Mixed With Water Proofing Compound As Per Manufacturer Instructions. Plaster Shall Be Extended Over Plain Cement Concrete Coving When The Same Is Green I.E. Plain Cement Concrete & Plaster Be Carried Out At The Same Time Complete All As Specified And Directed. (Iv) After Laying Sewage/ Plumbing Pipes With Fixtures In Position, 2 Coats Of Omiplas Ep-101 Epoxy Compound Shall Be Applied Complete All As Specified And Directed. (V) Testing Again Of Water Tightness By Ponding For 72 Hours & Rectifying Defects If Any Till Total Elimination Of Defects Complete All As Specified And Directed. (Vi) M&L To Fill The Sunken Floor With Plain Cement Concrete ( 1:5:10) Type E-2 Using 40Mm Graded Brick Aggregate Over The Treated Surface Complete All As Specified And Directed. (Vii) Provinding Spouts Of 25Mm Dia Gi Pipe Light Grade Projecting 450Mm From Clear Outer Suraface Of Wall With Mosquito Proof Cap On Inner Face Of Pipe Shall Be Provided To Drain Out Seepage Water, Including Cutting Holes And Making Good If Needed Complete All As Specified And Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Directed. , M & L 15Mm Thick Screed Bed In Cement Mortar 1:6 Under Floor Tiles, All As Specified And Directed , M&L For Heavy Duty Tiles Exterior Grade 300 X 300 X 10Mm In Cm 1:6, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match , M & L Anti Skid Ceramic Coloured Tiles Of Size 600X600x7-8Mm , In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match With The Colour Of Tiles Laid On, As Specified. , M & L Anti Skid Ceramic Coloured Tiles Of Size 400X400x7-8Mm , In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match With The Colour Of Tiles Laid On, As Specified. , M & L Glazed Ceramic Coloured Tiles In Vertical Surface 450X300x7-8Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over And Including 10Mm Thick Rendering In Cm 1:4 Etc. , Demolition Brick Work Or Stone/ Boulder Masonery Built In Cement Mortar Including All Quoins , Pillars Etc Complete All As Specified And Directed. , M&L For Brick Work Using Sub Class ‘B Old Size Bricks, Straight Or Curved On Plan Exceeding 6M Mean Radius, Built In Cm (1:6) , M & L Precast Cement Concrete Block Masonry With Solid Blocks Plain Cement Concrete Type C1 (1:3:6) (Using 20Mm Graded Aggregate) Exc 10Cm In Width And Setting In Cm 1:6 , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Stone Walls, Etc. Including Racking Out Joints, Hacking For Key, Scrubbing Down With Water Etc.&Removing Rubbish To A Distance Not Exc 250M , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls With Readiplast By Adding 17-19% Of Potable Water By Weight Of Material. For Thickness Above 15Mm, It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days- 10-12 Mpa/Bulk Density-1500-1600 Kg/Cum. Note : The Rate Quoted By The Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 10 Mtr Height, All As Specified And Directed. , S&F Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples, All As Specified And Directed. , M & L For Preparation Of New Or Previously Untreated Wood Based Surfaces Of Any Description, Over 10 Cm In Width Or Girth, Not Otherwise Described With Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
47.
Defence #11191786 Price Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Any Guage, Thickness, Including Nainital Pattern Or Similar Pattern Roof Covering Complete All As Specified And Directed. , Demolition Of Brick Work Or Stone Masonry Precast Plain Cement Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , Dismantling Of Wall/ Ceiling Board (Flbre Pulp, Insulation Etc) Or Insulation Boards/ Slabs / Blankets Any Thickness, Including Cover Fillets Complete All As Specified And Directed. , Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. , Dismantling Timber Scantlings 40 Sq. Cm And Over In Section, In Any Position Complete All As Specified , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Dismantling Water Tanks 500 Ltrs Capacity Complete All As Specified And Directed. , Dismantling Water Tanks Of Any Description, Capacity Exceeding 500 Litres But Not Exceeding1000 Liters Complete. , S&F In Repairs Of Galvanised Mild Steel Wire Cloth 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.18Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 4 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa (Az 150) As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F 0.63Mm Thick Galvanised Corrugated Ms Sheeting (Cgi Sheet Roofing) With Two Corrugation Side Laps, With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusive Fixed With Coach Screws And Washers As In Roofs Etc All As Specified , S&F 0.63Mm Thick Plain Galvanised Ms Sheeting Using Grade-O Sheets With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusives, As In Roof, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6 All As Specified And Directed. , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls By Adding 17-19% Of Potable Water By Weight Of Material For Thickness Above 15Mm It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days 10-12 Mpa/Bulk Density 1500-1600 Kg/M3. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 20 Mtr Ht All As Specified And Directed.Make Fosroc/ Sika/ Ultrarech/ Choksey , M&L For Preparation Of New Plastered Surfaces & Applying A Layer Of Birla Putty On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Distemper Complete All As Specified And Directed. , M/L For Complete Removal Of Existing Treatment For Preparing Old Painted Surfacess And Applying Two Coat Of Distemper Oil Emulsion Over A Coat Of Primer Complete All As Specified And Directed. , M&L Three Coats Of White Wash On Ceiling Including All Preparation Complete All As Sopecified , Material & Labour For Applying Two Or More Coats Of 100% Remium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance,Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives@ 1.43 Litre/ 10 Sqm Over And Including Primingcoat Of Exterior Primer Applied @ 0.90 Litre/ 10Sqm Over New Surfaces Complete All As Specified And Directed. , M&L Preparation Of Old Surfaces Including Cornices Etc And One Coat Of Oil Bound Distemper Complete All As Specified And Directed. , S&F 20Mm Thick 2Nd Class Soft Wood (Chir) Boarding Planned One Side Fixed With Butt Joints With Nails In Any Situation/Position Except Flooring And Skirting Complete All As Specified And Directed. , M&L For 2Nd Class Hard Wood Clean Sawn In As In Scantling Framed And Over 40Sqcm Fixed With Screws Etc All As Specified And Directed.. , S & F Second Class Hardwood 25 Mm Boarding Plain One Side With Butt Joint Fixed With Nails In Any Situation. Complete All As Specified And Directed. , S&F Of Powder Coated Grid Frame Work For False Celling Comprising Of The Following Sections For Making Partitions Of 605X605 Mm Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including 4Mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mmx24mmx0.3Mm Thick , Cross Tee Shall Be 28Mmx24mmx0.3Mm Thick And Wall Angle Shall Be 24Mmx24mmx0.3 Mm Thick Incl 4 Mm Thick E-Board Classic (Make-Everest) For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface Complete All As Specified And Directed.Complete All As Specified And Directed. , S&F Solid Pvc Wall Lining Dual Colour Consisting Of 5 Mm Thick Wood Grain Printed Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specification And Drawing Complete Fixing Arrangement Including Taking Down Old Existing Wooden Panelling Complete. , S & F 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing. , S&F In Repair 110Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
48.
Defence #11191783 Price Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Any Guage, Thickness, Including Nainital Pattern Or Similar Pattern Roof Covering Complete All As Specified And Directed. , Demolition Of Brick Work Or Stone Masonry Precast Plain Cement Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. , Dismantling Timber Scantlings 40 Sq. Cm And Over In Section, In Any Position Complete All As Specified , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Dismantling Water Tanks 500 Ltrs Capacity Complete All As Specified And Directed. , Dismantling Water Tanks Of Any Description, Capacity Exceeding 500 Litres But Not Exceeding1000 Liters Complete. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Not Exc 1.5 Sqm Each.& Removing To Or From Store All As Specifed & Directed. , Taking Down Chowkats Or Frames Exc 1.5 Sqm But Not Exc 4 Sqm Each With Shutters (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. , Dismantling Of Ceiling Board (Flbre Pulp, Insulation Etc) Or Insulation Boards/Slabs/Blankets Any Thickness, Including Cover Fillets Complete All As Specified And Directed. , S&F In Repairs Of Galvanised Mild Steel Wire Cloth 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.18Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 4 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa (Az 150) As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F 0.63Mm Thick Galvanised Corrugated Ms Sheeting (Cgi Sheet Roofing) With Two Corrugation Side Laps, With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusive Fixed With Coach Screws And Washers As In Roofs Etc All As Specified , S&F 0.63Mm Thick Plain Galvanised Ms Sheeting Using Grade-O Sheets With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusives, As In Roof, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Complete All As Specified And Directed. , S&F Of Powder Coated Grid Frame Work For False Celling Comprising Of The Following Sections For Making Partitions Of 600X600 Mm Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including 4Mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mmx24mmx0.3Mm Thick , Cross Tee Shall Be 28Mmx24mmx0.3Mm Thick And Wall Angle Shall Be 24Mmx24mmx0.3 Mm Thick Incl 4 Mm Thick E-Board Classic (Make-Everest) For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface Complete All As Specified And Directed.Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6 All As Specified And Directed. , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls By Adding 17-19% Of Potable Water By Weight Of Material For Thickness Above 15Mm It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days 10-12 Mpa/Bulk Density 1500-1600 Kg/M3. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 20 Mtr Ht All As Specified And Directed.Make Fosroc/ Sika/ Ultrarech/ Choksey , M&L For Preparation Of New Plastered Surfaces & Applying A Layer Of Birla Putty On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Distemper Complete All As Specified And Directed. , M/L For Complete Removal Of Existing Treatment For Preparing Old Painted Surfacess And Applying Two Coat Of Distemper Oil Emulsion Over A Coat Of Primer Complete All As Specified And Directed. , M&L Three Coats Of White Wash On Ceiling Including All Preparation Complete All As Sopecified , Material & Labour For Applying Two Or More Coats Of 100% Remium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance,Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives@ 1.43 Litre/ 10 Sqm Over And Including Primingcoat Of Exterior Primer Applied @ 0.90 Litre/ 10Sqm Over New Surfaces Complete All As Specified And Directed. , M&L Preparation Of Old Surfaces Including Cornices Etc And One Coat Of Oil Bound Distemper Complete All As Specified And Directed. , S&F 20Mm Thick 2Nd Class Soft Wood (Chir) Boarding Planned One Side Fixed With Butt Joints With Nails In Any Situation/Position Except Flooring And Skirting Complete All As Specified And Directed. , M&L For 2Nd Class Hard Wood Clean Sawn In As In Scantling Framed And Over 40Sqcm Fixed With Screws Etc All As Specified And Directed.. , S&F In Repair 110Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , S&F In Repair 75Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , M&L 300X450x7mm Thick Glazed Ceramic Digital Tiles Coloured Incl , Design And Pattern As Approved Fixed As In Vertical Surface Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Cement With Colour Pigment To Match Incl Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Complete All As Specified And Directed. , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.11 Sqm But N.Exc. 0.18 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigment Incl 15Mm Thick Screed Bed In Cm 1:6 Complete All As Spd , M&L For 15Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , M&L For 20 Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Bib Tap Long Body Cp, Screwed For Iron Pipes Complete All As Specified And Directed , S&F Angle Cock 15 Mm Bore Brass Chromium Plated, Screwed Both Ends For Pipes Or For Unions Fixed In Repairs Including Making Good To Match With Existing Surface , S&F Pillar Taps 15 Mm Bore, Brass Chromium Plated , Screwed Down High Pressure With Or Without Letter Hot Or Cold With Long Screwed Shanks And Fly Nut Complete All As Specified, Fixed In Repairs. , S&F Bib Tap Standard Of Ptmt (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath Fitting), Any Colour, Screwed Foriron Pipe 15 Mm Bore Pipe (Minimum Weight 90 Gm) All As Specified, Fixed In Repairs (Make : Prayag Or Equivelent As Approved) , S&F In Repair Polymer White (Polypropeylene Delrin And Abs) Low Level Flushing Cistern 10 Ltrs Capacity, Valveless, Syphonic Action Type Complete With Inlet, Ball Valve Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete, Complete All As Specified And Directed. , S&F In Repairs, 550X400mm Vitreous China, Wash Hand Basin , Flat Back With Pedestal Excluding Trap And Waste Chain And Plug And Porcelain Stopper Including Sutaible Size Brackets Waste Pipe And Waste Coupling Complete All As Specified And Directed. , S&F Vitreous China Squatting Pan Orrissa Pattern Size 580 X 440 Mm White With Intregal Foot Rests, With & Including P Or S Trap (Excluding Material & Labour Of Flushing Cistern And Flush Pipe) Including Conection To Trap And To Flush Pipe Etc Complete Including Making Good To Floor Complete All As Specified And Directed Fixed In Repairs. , S& F In Repair Vitreous China Premium/ 1St Quality Wash Down Water Closet Ewc White/ Ivory/Off White (Closed Pattern Incl All Necessary Accessories Like Rag Bolts/ Gel Gasket Etc. (Excluding Flushing Cistern & Flush Pipe) Complete In All Respect All As Specified. , M&L Pvc (Swr) Floor Trap 75Mm Dia Plain With Grating Including Jointing With Solvent Cement Etc Complete, Fixed In Repair. , S&F Pvc Circular Top Cover Suitable To Rotational Moulded Polyethylene Water Storage Tanks Of 300 /500 Litres Capacity Tanks Of Standard Mares, With 6 Mm Dia Nut And Bolts On Two Ends Of Cover To Act As Hinge As Will As Locking Arrangement For Side Opening , M&L For Sunken Floor Treatment As Described As Under (I) To (Vii) :- (I) Demolition Of Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Or In Any Type Of Filling In Sunken Portion & Cleaned The Sunken Portion Incl Vertical Wall Surface Complete As Directed. (Ii) M&L To Fill The Sunken Floor With Plain Cement Concrete ( 1:5:10) Type E-2 Using Bk Aggregate Over The Treated Surface Complete All As Specified And Directed. (Iii) M& L 40Mm Thick (Min) Plain Cement Concrete (1:2:4) Type B-0 Using 12.5 Mm Graded Stone Aggregate With Integral Water Proofing Compound As Per Manufacturer Instructions On Bottom Of Sunken Portion With Proper Slope Towards Spout. Vertical Sides Shall Be Plastered In Cm (1:3) 15 Mm Thick Mixed With Water Proofing Compound As Per Manufacturer Instructions. Plaster Shall Be Extended Over Plain Cement Concrete Coving When The Same Is Green I.E. Plain Cement Concrete & Plaster Be Carried Out At The Same Time Complete All As Specified And Directed.(Iv) After Laying Sewage/ Plumbing Pipes With Fixtures In Position 2 Coats Of Omiplas Ep-101 Epoxy Compound Shall Be Applied Complete All As Specified And Directed.(V) Spouts Of 25Mm Dia Gi Pipe Light Grade Projecting 450Mm Clear Of Face Outer A Wall With Mosquito Proof Cap On Inner Face Of Pipe Shall Be Provided To Drain Out Seepage Water ,Including Cutting Holes And Making Good If Needed As Specified And Directed. (Vi) Test Again Of Water Tightness By Pounding For 72 Hours & Rectify Defects If Any Till Total Elimination Of Defects Complete All As Specified And Directed.The Sunken Portion Shall Be Tested For Leakage / Seepage / Dampness By Pounding With Water For 72 Hours. In Case Any Defect Is Noticed The Portion Shall Be Grouted With Cement Slurry Mixed With Suitable Chemical & Tested Again. The Process Of Grouting And Testing Shall Be Repeated Till Leakage / Seepage / Dampness Is Eliminated. , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/ Window/ Ceosetory Window & Other Frames/ Chowkhat Of Size 45 X 70 Mm Comprising Of Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wwod Powder/ Rick Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Stat Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modules Of Elasticity 900 N / Mm 2 And Resistance To Spread Of Flame Of Class A Catogory With Property Of Being Termite/ Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With Ms Hold Fast/Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge (M.S. Hold Fast/ Lugs Or Ss Dash Fasteners Shall Be Paid For Separately). , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Plain Flush Door Shutter Of 35 Mm Thick Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/ Cum And Screw Withdrwal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N Mm2 Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Catogary With Property Of Being Termite/ Borer Proof, Water/ Moisture Proof And Fire Retardanat And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws, All As Per Direction Of Engineer-In-Charge (Note:- Stainless Steel Butt Hinges And Necessary Ss Screws Shall Be Paid Separately. , S&F Mild Steel Work As Hold Fasts, Bands, Straps, Supports Or Stays For Pipes Eaves Gutter Including Bolts If Required, Hooks (Stay), Clamps And Similar Small Articles, Conforming Tofe 310-0 Or Fe 410-0 Complete All As Specified And Directed. , S&F 100Mm Size Ms Butt Hinges, Medium Weight, Cold Rolled And Fixed Complete All As Specified And Directed. , S&F 150Mm Long Aluminium Tower Bolt And Fixed Complete All As Specified And Directed. , S&F 125 Mm Size Aluminium Handle Plate Type Anodised Complete All As Specified And Directed. , M & L For Roof Surface Must Be Pressure-Washed With Water With, Is To Be Used To And/ Or Remove All Dirt, Dust, Chalking And Waste Products. Remove Algae, Mold By Using Bleach Solution. 2 Tiles Joint Repair All Visible And Joint More Than 0.50Mm And Not Giving Hollow Sound, On The Tiles Roof Or At The Junctions Of Flat Roof & Vertical Parapet Wall, Pipe Joints, Should Be Cut And Widen V Shape With Mechanical Cutter In The Size (6Mm W X 6Mm D) And Fill With Pmm Methodology.Glass Fiber Apply Urp Or Primeseal A On The Well Prepared Groove, Allow To Cure Tack Free. Followed By Filling All The Joints Covering The Entire Area Uniformly With Suitable Chemical. Allow Chemical To Cure A Minimum 24 Hours. Apply Minimum 50Mm-100Mm Width 45 Gms Glass Fibre Mesh/ Non-Woven Geo Testile Fleece With The Coat Of Roofseal Classic Along The Length Of Crack When The 1St Coat Is Still In Wet Condition. Apply The Second Coat With An Interval If 4-6 Hours. Waterproofing: Apply A Coat Of Roofseal Classic (Diluted With Water In The Ratio 2:1) As Self Priming 14.0-18.0 Sq. Mt/Litre.Allow Coating To Dry For 3-4 Hours. Applt Two Coats Of Dr Fixit Roofseal Classic/Litre/Coat, Without, The Rate Of Application Being The Same For Both The Coats. This Would Ensure Correct Consumption Of Material That Will Deliver A Total Of Dft Of Microns. Allow The System To Air Cure For 5 Days Minimum. Check To See No Void Surface Is Left Untreated/Uncoated. The Material Having Following Technical Specification As Per Astm D 6083 M- Type Ii, Attains A Tensile Strength Of 2.5 N/Mm2 Confirming To Astm D 2370: Elongation At Break 300% Confirming Astm D 2370, Adhesion To Concrete 2.0N/Mm2 Confirming Astm D 4541 And Crack Bridging Ability Up To 2Mm, Air Cure The Coating For 7 Days Before Water Pound Test For 48 Hrs. The System Comes With 7 Year Waterproofing Warranty From Service Provider. For Vertical Surface : Apply 2 Coat Of Dr Fixit Roofseal Classic With Forced Coverage Of /Litre/Coat. Entire Terrace Should Be Coated With Roofseal Classic Alongwith Parapet Walls Needs To Be Enveloped With Roofseal Classic/Raincoat System. The Total 3 Coats Treatment Inclu Taking Down/Dismantling Of Old Tarfelt/Old Unserviceable Roof Treatment From Reinforced Cement Concrete Roof By Scrapping, Broomig And Washing With Water Etc Including 10Mm Thick Rendering In Cm 1:3 With Water Proofing Compound Complete All As . Make : Dr Fixit, Asian Or Equivalent (Note : The Treatment Should Be Carried Out Through Authorised Applicator Only) , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
49.
Public Administrative Department #11187273 AOC
Tender For Safety Related Works At Maa Hospital, Postal Colony, Chembur E Mumbai. - Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 2820 LPM (Litres/min.) at 88m centrifugal type pump 2 SITC of Jockey Pump of 240 LPM at 88m head 3 SITC of Booster Pump of 450 LPM at 88 m head 4 415V Main Distribution Panel 1 short circuit reating 50kA for 1 Sec. 630A (Thermal magnetic overload, short circuit release & earth leakage module) MCCB with rotary operating mechanism as incomer with digital ammeter, voltmeter with selector switches, phase indicating lamp with required accessories, 1Nos. 63A, 3Noss. Of 100A, 2Noss. 160A & 200A (total 8Noss.) MCCB of short circuit rating 25kA for 1 sec. as outgoings. 5 Providing and fixing in position G.I. Heavy grade C class pipes 200 mm 6 Providing and fixing in position G.I. Heavy grade C class pipes150 mm 7 Providing and fixing in position G.I. Heavy grade C class pipes100 mm 8 Providing and fixing in position G.I. Heavy grade C class pipes 80 mm 9 Providing and fixing in position G.I. Heavy grade C class pipes 65 mm 10 Providing and fixing in position G.I. Heavy grade C class pipes 50 mm 11 Providing and fixing in position G.I. Heavy grade C class pipes 40 mm 12 Providing and fixing in position G.I. Heavy grade C class pipes 32 mm 13 Providing and fixing in position G.I. Heavy grade C class pipes 25 mm 14 Painting of 7 mtr G.I./M.S. Pole (All types). 15 Supplying & Installing cast iron double flange butterfly valve 200 mm 16 WAFER TYPE BUTTERFLY VALVES: -150 mm dia. 17 WAFER TYPE BUTTERFLY VALVES: -100 mm dia. 18 WAFER TYPE BUTTERFLY VALVES: -80 mm dia. 19 Supplying and installing double flange NRV 150 mm 20 Supplying and installing double flange NRV 80 mm 21 Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0- 14 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc 22 Supplying and installing pressure switch with 12/15 mm Ø isolation valve, G.I. nipple, elbow etc. in an approved manner as per specification 23 1st category Cu armoured cables FRLSZ outer sheathed- 3.5C x 35 Sq.mm 24 Cable End Termination For Aluminium Cables – 3C x 35 Sq.mm 25 Earthing Continuity Conductors -50 x 6mm GI 26 2nd category Cu armoured cables FRLSZ outer sheathed- 2C x 1.5 Sq.mm 27 50 x 50 x 6 mm of M.S.angle. 28 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 29 Supplying & installing moulded HDP / Fibre water tank. for -ve suction only, having capacity 1000 ltrs.fitted with necessary accessories complete as per specification 30 Supplying and erecting 20/25mm Ø G.M.air release cock, with necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification 31 Supplying and installing Air Vessel of 300 mm Ø 1.5m in height M.S. tank installed inside pump house as per specification 32 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -150 mm dia. 33 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -100 mm dia 34 Supplying and installing gun metal Double outlet hydrant valve fitted with necessary accessories 35 Supplying and installing gun metal single outlet hydrant valve fitted with necessary accessories 36 Supplying Stainless Steel branch Pipe 63 mmØ fitted with 20 mm dia detachable hexagonalnozzle as per specifications 37 Providing and fixing in position 2 lengths of 15 M long flexible canvas rubber lined hose reels 63 dia with adapter, branch pipe and nozzle and storing them in metal cabinets with lockable glass shutters and fixing the metal cabinet at ground level in a location where it can be easily spotted including painting etc 38 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8x6) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour 39 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 40 Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 100 mm Ring Main of Fire Fighting System. 41 Excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 Cu. Mtr. = 2.2 RMT. 42 Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification 43 Cement concrete foundation using M-20 cement concrete mix with J shaped foundation bolts where required 44 Supply & Laying of double wall corrugated ( DWC) pipe 120 mm OD / 103.5 mm I.D. 45 Excavating the trenches and refilling the same after the cable is laid in approved manner (Size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 Cu. Mtr. = 2.2 RMT. And reinstatement. 46 Providing, detailing, composite fabricating members like Trusses, N-girders, girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using M.S. hollow tubular steel sections (circular & rectangular pipes), of TATA Structura Make or equivalent conforming to IS 1239 part 1 and 2 and of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), including transportion of the same to site, erection of structural steel members for all heights & at all levels, provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding, removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. 47 Bare Galvalume/zincalume sheets for roofing 48 Rubber mat 2mm thick size 3x5 feet 49 Earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate & 50 mm dia. G.I. pipe, 3000mm long GI pipe (Class B or better) earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25x3 GI strip/ / 2X8SWG G.I. wire up to chamber (wire or strip size as per fault level), disconnecting links with 600 x 600 mm (clear) RCC chamber & heavy duty 3mm thick CI chequered plate cover with hinge & stainless steel bolts. Bentonite/ Charcol & Salt shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope 50 Earthing Continuity Conductors -25 x 6mm Tinned copper 51 Earthing Continuity Conductors – Bare Copper Conductor size 12 SWG 52 45 Degree Leg Press (free Wts.) 53 Supply, Installation, testing & commissioning of addressable 2 loop main fire alarm electronic control panel, expendable up to 4 loop & having maximum 250 devices (any combination detectors plus devices) per loop & Audio/ Visual alarm complete as per IS: 2189 specification - modular type front operated with interlocking door arrangement totally enclosed dust and vermin proof for indoor type applications. 54 Supply, Installation, testing & commissioning of Active Repeater panel with all accessories, which shall be replica of main fire alarm panel with control keys I,e. Mute, silent & sounder alarm. 55 Supply, Installation, testing & commissioning of expandable Loop card for main fire alarm electronic control panel, shall support 254 devices both detectors and modules and shall support both class A & class B wiring. 56 Supply, Installation, testing & commissioning of Intelligent multi- criteria Detector along with mounting box & termination glands. 57 Supply, Installation, testing & commissioning of Intelligent Photoelectric Smoke Detector along with mounting box & termination glands. 58 Supply, Installation, testing & commissioning of Addressable Manual call point/ station with mounting back box 59 Supply, Installation, testing & commissioning of Addressable control Relay module with required accessories along with junction box, glands and terminators ( For AC trip off, Access trip off, PA system, sprinkler flow switch, lift interface, sounder, fire fighter & telephone jack) 60 Supply, Installation, testing & commissioning of Isolator Module along with mounting box & termination glands. 61 Supply, Installation, testing & commissioning of remote response indicator 62 Supply, Installation, testing & commissioning of Strobe Lights along with mounting box & termination glands. 63 Cable End Termination For Copper Cables – 2C x 1.5 / 2.5 Sq.mm 64 Supply, Installation, testing & commissioning of 2Cx1.5 sq.mm armoured RED color copper FRLS cable with necessary saddles, screws, junction boxes, sleeves, elbows couplings etc. for Fire alarm System 65 Supply and installation of Mixer amplifier 120W (4 channel input & 1 line level balanced output) 66 Supply and installation of Booster amplifier 300W with all accessories. 67 6W/100V. PA Ceiling Speaker 68 Delegate unit Microphone 69 Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver Paint. 70 SITC of Auto glow signage for Emergency Fire Exit 71 SITC of Auto glow signage for Do not use lift in case of Fire etc. 72 Clean Agent Fire Extinguisher 73 Fire B-Form Charges 74 Mock drill test (1st Year and 3rd Year) 75 CSMC 5% for 1st year 76 CSMC 5% for 2nd year 77 CSMC 5% for 3rdyear
Contract Date: May 29, 2026 Contract Value : 1.35 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
50.
Defence #11186924 Price Bid
Tender for Dismantling Of Wall And Ceiling Boards/Pvc Panelling (Fiber , Pulp, Insulation Etc, ) Or Insulation Boards/Slabs/Blankets, Any Thickness Including Cover Fillet Complete All As Specified And Directed. , S&F For Powder Coated Aluminium Anodised Snap Gird System Of Grid Size 600X600 Mm Fixed To Walls With Raw Plugs And Screws And Hang To Roof Members With 2 Mm Dia Gi Wire Comprising Of The Main Tee 28X24x3 Mm Thick, Cross Tee 28X24x3 Mm Thick Wall Angle 24X24x3mm Thick Sections, Complete All As Specified And Directed. , S&F 4Mm Thick Everest Designer Ceiling (E-Boards Classic) Board/Tile For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Gi/Aluminium Snap Grid As In Ceiling With And Including Dusting Of Surface And Applying Two Coats Of Oil Bond Distemper Over A Coat Or Primer, Complete All As Specified And Directed , S&F 6Mm Thick Decorative Pvc Sheet Hollow For Insulation And Acoustic Purpose On Wall/Ceiling Surface, Screw To Timber Frame Work For Levelling Of Wall As Reqd, Including With Panelling To Vectical Surfaces, Fixed With Rawl Plug And Screws, Complete All As Specified And Directed. , Dismantling Of Plain Or Corrugated Steel Sheting, Any Gauge, Thickness, Including Nainital Or Similar Pattern Roof Coverings, All As Specified & Drected By Engr-In-Charge , S&F Pre-Painted Galvalume Aluminium Zinc Oating Gi Based Corrugated Steel Sheeting 0.50Mm Thick Any Colour Having Tensile Strength 550Mpa In Roof Coverings Fixed With Self Tapping Screws Including , S&F Pre-Painted Galvalume Aluminium Zinc Oating Gi Based Plain Steel Sheeting 0.50Mm Thick Any Colour Having Tensile Strength 550Mpa In Roof Coverings/ Cladding To Wall, Fixed With Self Tapping Screws Including , S&F Galvanised, Corrugated 0.63Mm Thick Mild Steel Sheeting Wit Two Corrugations Side Lap, Fixed With L-Type Or J-Type Or Cranked Hook Bolts, With Bitumen Washer/Screws , S&F 0.63Mm Thick Mild Steel Plain Sheeting, Galvanised, In Ridge, Hips, Valley Gutters, Drip And Straight Flashings (Lengths And Girth As Fixed) With Grade Of Zinc Coating 275 Fixed With L-Type Or J-Type Or Cranked Hook Bolts, With Bitumen Washer/ Screws In Normal/Nainital Pattern, All As Specified And Directed. , Demolition Of Concrete In Ground Floors And Paving N Exc 15 Cm Thickness (Below Or Above Ground Level), Complete All As Specified & Directed By Engineer-In-Charge , Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc. , M&L For 75Mm Thick Plain Cement Concrete 1:4:8, Type D2 (Using 40 Mm Graded Stone Aggregate) As In Sub Base To Flooring, Complete All As Specified & Directed By Engr-In-Charge. , Providing And Laying 80Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-30 Grade With Approved Colour, Design & Pattern As In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Fine Sand And Cutting Of Paver Block As Per Required Size And Pattern, Finishing And Sweeping Extra Sand; Complete. , Supplying And Laying App Based Modified Water Proofing Polymeric Membrane, Reinforcemed With Nonwoven Polyster Non Wove Fabric Matt (Weight Not Less Than 150 Gms/Sqm) Of Minimum 3 Mm Thick And Minimum Weighing Not Less Than 3 Kg/Sqm,Laid Over Bituminous Primer Conforming To Is 3384-1965 @.30 Kg/Sqm To Be Applied On Prepared Surface And Apply A Coat Of Bitumen 85/25 Grade @1.2 Kg/Sqm Over Primer, 15Mm Thick Plastered Sufaces Layer In Cm 1:4 With Water Proofing Compound (Wpc) @ 3% By Weight On Concrete Surface Roof / Parapet, Over Lap Of Minimum 75 Mm On Longitudinal Direction And 100 Mm On The Transverse Direction By Thermo-Fused Torch Flame Application Method With 02 Coats Of Aluminium Paint Over App Membrane Including Taking Down Of Existing Roof Treatement, Complete All As Specified And Directed. , S&F In Replacement 8Mm Thick, Wooden Pieces, Machine Pressured One Side Laminated And Other Side Balancing Green, As In Parquet Flooring With And Including Necessary Padding As Soft Wool Graded Type As Reuired At Site, Fixed With Adhesive As Per Menufactures Instructions Including Taking Own Old Wooden Flooring With Or Without Plywood Complete All As Specified And Directed. , M&L For 9Mm Thick Plywood, Graded Bwr, Type Bb Fixed With Rawl Plug And Screws To Timber Framework Fixed As In Repair Of Any Thickness Complete All As Specified And Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Directed. , M&L 15Mm Thick Screed Bed In Cement Mortar 1:6 Under Floor Tiles, All As Specified And Directed. , M & L Anti Skid Ceramic Coloured Tiles Of Size 600X600x7-8Mm , In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match With The Colour Of Tiles Laid On, As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
TenderDetail
Loading tenders