View Bid Results For Gateway Tenders

We found 1687 Bid Results related to gateway tenders. You can find Contractor details who won gateway tenders along with contract details in Bid awards announcements section.

Filters
Stage
1395
176
116
Tender Publishing Platform
927
760
State / UT
37
265
176
129
125
92
85
81
78
71
57
54
54
53
52
52
43
35
29
21
19
15
14
14
13
11
11
8
6
6
5
4
2
2
2
1
1
1
Contract Value
489
492
496
206
Publish Date
6
1
0
0
0
Sector
32
379
176
157
125
122
118
90
85
64
45
38
34
34
27
25
17
17
16
15
14
14
11
10
10
9
8
7
6
5
3
2
1
Ownership
7
806
437
288
139
11
2
1
Within keyword
Active filters:
Showing 1–34 of 1687 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 21.48 Lakh
Local Bodies No of Bidders 1
2.
Communications and Information Technology  #11475627 Technical Bid
Tender for Tender For Supply, Installation, Commissioning And Maintenance Of Cctv Systems For Igr 3.0 Project Under Lease Cum Service Model For A Period Of 5 Years , Annexure - 13 Price Bid , Cctv Camera 2 Mp With 512 Gb Sd Card With Voice Recording , 8 Ch Nvr , 20 Tb (10*2) Hard Disk , 8 Port Gigabit Layer 2 Poe Switch , Cat 6 Network Cable (For Connecting Three Ip Cameras, Nvr And Desktop Computer) (Unit Cost In Mtr To Be Quoted) , Desktop Computer For Sro Office , Monitor 27 For special repair View With 15 Mtrs Hdmi Cable , 1 Kva Ups With 120 Min Backup With Mcb , Earthing Systems In All Sro , Labor Charges For Lan Cabling And Related Services Including Ip Configuration. 1 Pvc Pipe With Fixtures (Cat 6) , Ups Output Wiring From 1 Kva On-Line Ups To Desktop And 6U Rack (3C*2.5Sq.Mm) , Labor Charges For Ups Wiring And Related Services, 1 Pvc Pipe With Fixtures , 2* 5 A Switch And Socket , 1 *15 A Ss Combined , Active Led Videowall With Controller , Display Monitor 55 Inch , 24 Port L3 Ethernet Switch With 4 Sfp+ Port , Workstation For Dig & Ig Office For Vms Client & Workstation For Time And Attendance Database And Application Hosting , 42 U Server Rack Customisable - Ig Office , 24 U Server Rack - Dig Office To Place Ai Servers , Centrally Managed Cloud Platform Required For Whatsapp Integration - Secured Storage, Video Dissemination. Cost For Software Support, Enhancement , Server For Video Management Platform (3 Nos) - 3 Numbers Of Physical Server Or Equivalent Solution To Offer Useable Resources Of 48 Cores/ 512 Gb/ 12 Tb Of Storage Post 1 Node Failure , Management Portal To Store And Send Registration Videos , Time And Attendance Management Software As Per Technical Requirements , Finger Print Scanner With Software Kit , Server For The Video Management Software- Igr Ho (Management) , Server For The Video Management Software- Igr Ho (Streaming) , Server For Ai Functions (11 + 1) , Vms Licenses For 3000 Cameras With Client Login , Ai Functions Vms Licenses For 600 Cameras - special repair Camera1 , Alternate Gateway For Tnega Whatsapp Gateway , Manpower-1 Ipc Operator/Deo- Year1 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year2 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year3 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year4 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year5 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year1(Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year2 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year3 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year4 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year5 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year1 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year2 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year3 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year4 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year5 (Unit Cost Per Resource Per Year To Be Quoted) , Setting Up Necessary Infrastructure In Igr Office For Running All Server Services Such As Ups, Genset, Ac, Rack, Network Cables, San Switch, Router, Static Ips, Fire Wall, Plug Points, Installation Of Ports And Other Required Accessories - Qty - As Required To Meet The Sla , Aggregation Bandwidth With Back Up Connectivity For 5 Years , Comprehensive annual maintenance contract Of Existing 1150 Ip Camera In Record Room (S) Of Sro (Unit Cost For 5 Years Per Camera To Be Quoted) , Integration Of 1150 With New System , Shifting Cost For Ip Camera And Other Related Infrastructure From Sro Office To Another. , Cost For Ip Camera Installation Setup In New Office - For New Office 5 No Ip Camera, 2 No Nvr, 2 No 8 Poe Port Switch, 20 Tb Hdd, Computer, Monitor, Ups Installations Commissions As Per Technical Specifications Each Items In Above
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Ref. Documents Contract Value : 1.40 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
4.
Defence #11453177 AOC
Bids Are invited for Ceiling Speakers , Column Array Speakers , Lifier For Ceiling Speakers , Lifier For Column Array Speakers , Digital Signal Processor , Boundary Layer Microphones , On Off Button For Boundary Layer Microphones , Switch Box For Boundary Layer Microphones , Ceiling Tile Microphone Array , Main Display , Side Display , Annotation Panel , Cable Manager For Table , Hdmi Switcher , Hdmi Splitter , Hdmi Extender , Usb Tx Multiformat Switcher , Usb Rx Multi Format Switcher , Usb Data Matrix Switch , Ptz Camera , Speaker Tracking Camera , Hdmi To Usb Capture Card , Voice Tracking Device , Control System With Touch Controller , Network Switch , Room Scheduler , Pdu With Humidity And Temperature Sensor , Ceiling Mount Document Scanner , Equipment Rack , Ups 10 Kva Ups With 60 Min Backup , Ups 3 Kva Ups With 60 Min Back Up , Acoustic Door With Fitting Laminate And Door Frame , Chair , Hot And Cold Ac 2 Ton , Room Air Purifier , Bio Metric Door Access Control , Auto Fire Suppression System For Av Rack , High Quality Wireless Keyboard And Mouse , Led Surface Recessed Mounted Panel With Luminous Web , 12 Channel Signal Dimmer Controller , 12 Channel Controller , Display Keypad Panel For Workstations , Network Router For Automation System , Sitc Supply Installation Testing And Commissioning , Acoustic Wall Paneling , Acoustic False Ceiling , Wooden Conference Table , Executive Chair , Acoustic Carpet Flooring , Power Supply For Lighting Control Network , Lighting Control Communicaiton Gateway Total Quantity : 4070
Contract Date: Ref. Documents Contract Value : 3.84 Crore
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
6.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
11.
Contract Date: Ref. Documents Contract Value : 6.50 Lakh
Local Bodies No of Bidders 1
13.
Civil Aviation #11346997 AOC
Bids Are invited for Supply of 24 Port L3 PoE Network Switch with all 1G SFP port - 24 Port L3 Core Switch 04 Fiber Port , Supply of 24 Port L2 PoE Network Switch with 1G SFP port-4 - 24 Port L2 POE Managed Switch 04 Fiber Port , Supply of 1 G SFP LC LR 10km SMF Transceiver - 1 G SFP LC LR 10km SMF Transceiver , Supply of IP Phone as per Specification , Supply of Digital Phone as per specification , Supply of Operator Console , Supply of FXS Gateway - 32 Port FXS Gateway , Supply of Cat6A STP Cable , Supply of PVC Conduit Pipe with Jointer Band - PVC Conduit 32mm for laying of OFC Cable/ Cat6 Cable inside building , Supply of 12 port LIU with pigtail , Supply of 12 Core SMF OFC Cable , Supply of RC Cable - 1 Pair RC Cable , Supply of OFC patch cord-1 Mtr - OFC Patch Cord Single Mode LC-LC Duplex- 1Mtr , Supply of OFC patch cord-3 Mtr - OFC Patch Cord Single Mode LC-LC Duplex- 3Mtr , Supply of 24 port Cat6A Patch Panel , Supply of Cat6-A IO Box Single RJ45 Port with Face Plate and IO Jack , Supply of 1U PVC Cable Manager - 1U PVC Cable Manager , Supply of CAT6-A RJ45 Patch Cord 1 MTR - Cat6-A RJ45 Patch Cord 1 MTR , Supply of CAT6-A RJ45 Patch Cord 2 MTR - Cat6-A RJ45 Patch Cord 2 MTR , Supply of 42U Floor Mounting Network Rack - 42U floor Mounting Network rack with Cable Manager and PDU with accessories , Supply of 27U Floor Mounting Network Rack - 27U Floor Mounting Network rack with Cable Manager and PDU with accessories , Supply of Copper plate Earthing - Copper plate with Earthing , Supply of 3 core 6 sqmm multi strand PVC insulated PVC sheathed copper conductor power cable - 3 core 6 sqmm multi strand PVC insulated PVC sheathed copper conductor power cable , Supply of 16 AMP Dual Pole MCB with Box - Supply of 16 AMP Dual Pole MCB with Box for connect to Rack UPS , Supply of installation Accessories - LAN Tester-2 RJ45 Crimping Tools-2 , RJ45-200 nos UV Protected nylon cable ties-500 etc & any other accessorises per site requirements , ITC of the complete system alongwith documentation , 1st Years comprehensive AMC with Spare after warranty - CAMC , 2nd Years comprehensive AMC with Spare after warranty - CAMC Total Quantity : 16056
Contract Date: Ref. Documents Contract Value : 1.44 Crore
Boards / Undertakings / PSU No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: May 28, 2026 Contract Value : 2.50 Lakh
Local Bodies No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Uttar Pradesh View Result →
21.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
22.
Railways #11287401 AOC
Supply Of supply installation testing and commissioning of gateways as per schedule of requirements , supply, installation, testing and commissioning of dcus/gateways/ allocation of sim network service provider and the arrangement of sim cards to enable reliable medium for two-way communication between smart meter & amp:, hes (head end system) over rf mesh network/cellular network. 1. the dcu/ gateway shall be compatible with the smart meters mentioned above. rf mesh network should use 865-86 7 mhz frequency band. 2. the data acquisition (push/pull) frequency shall be configurable 15 min, 30 min o r 60 minutes. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. 3. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. 4. sufficient number of gateways shall be installed in such a way that all the meters are covered in th e network efficiently. 5. it shall be capable to handle data of minimum 500 nos. of any type of smart meter (1ph/3ph). it shall be able to communicate with the nearest meters at a distance of at least 300 m, dependi ng on topographical features. 6. communication of the nearest meters with other meters shall be establish ed through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. 7. rf mesh shall support at least 15 no. of hops. 8. the equipment shall be weather-proof and dust-proof (minim um rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc. 9. it sha ll have passed the following emc tests from reputed lab: conducted emission, electrostatic discharge (esd ), radiated immunity, electrical fast transient (eft) - burst, surge, rf conducted disturbances. 10. rf mes h network shall be established to meet the slas as mentioned in tender document. 11. replacement warra nty period shall be 66 (sixty-six) months from the date of supply or 60 (sixty) months from the date of com missioning, whichever is earlier. [ warranty period: 30 months after the date of delivery ] ]
Contract Date: Jun 15, 2026 Contract Value : 13.18 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 1
25.
Petroleum and Natural Gas #11266046 AOC
Bids Are invited for D,S,I,C Of Radar Gauges - Design, Manufacture And Supply, Installation, Commissioning & Integration To Existing System Of Tank Radar Level Gauge , D,S,I,C Of Multispot Tem Sensor - Design, Manufacture And Supply Of Multi Input Average Temperature Transmitter And Multi-Spot Temperature Sensor , D,I,S,C Of Hi-Hi Level Tunning - Design, Manufacture And Supply Of Hi-Hi Level Switch Insertion Length 1000- 2000 Mm , D,S,I,C Of Pressure Transmitter - Pressure Transmitter With Ff Output For Obtaining Density As Per Api Latest Standard , Sply And Laying Of 1.5Sqmm 2Pair Cable - Supply, Laying Of 2 Pair 1.5 Sqmm Signal Cable For Radar To Hub, Hub To Antenna And Level Switch To Jb. , Sply And Laying Of 1Sqmm 12Core Cable - Supply, Laying Of 12 Core 1 Sqmm Control Cable. , Sply And Laying Of 2.5Sqmm 3Core Cable - Supply, Laying Of 3 Core 2.5 Sqmm Power Cable , Sply And Fixing Of Flp Power Jb - Supply, Fixing Of Flp Junction Box Power , Sply And Fixing Of Sil2 Jb - Supply, Fixing Of Sil 2 Jb For Switch Cable To Multi Core Cable Junction. , Sply And Fixing Of Thum Jb - Supply, Fixing Of Jb For Thum , Sply And Fixing Of 1By2 Inch Npt Cable Gland - Supply, Fixing Of Cable Gland 1/2 Inch Npt , Sply And Fixing Of 3By4 Inch Npt Cable Gland - Supply, Fixing Of Cable Gland 3/4 Inch Npt , Sply And Fixing Of 1 Inch Npt Cable Gland - Supply, Fixing Of Cable Gland 1 Inch Npt , Sply And Fixing Of 1By2 Inch Npt Blind Plug - Supply, Fixing Of Blind Plugs 1/2 Inch Npt , Sply And Fixing Of Power Isolation Switch - Supply, Fixing Of Power Isolation Switch , Wireless Connect Redundancy - Wireless Gateway With Redundancy (1 Pair) With Minimum 8 Nos. Discrete Transmitter/Repeaters , 1St Year Amc - Non Camc 1St Year , 2Nd Year Amc - Non Camc 2Nd Year , 3Rd Year Amc - Non Camc 3Rd Year , 4Th Year Amc - Non Camc 4Th Year , 5Th Year Amc - Non Camc 5Th Year , Sply And Fixing Of Earthing Wire 4Mm - Supply, Laying Of Earthing Cable 4Mm. Total Quantity : 4066
Contract Date: Ref. Documents Contract Value : 1.20 Crore
Boards / Undertakings / PSU No of Bidders 2
Dadra And Nagar Haveli View Result →
26.
Railways #11265038 AOC
Design, Manufacture, Supply, Installation, Testing, Commissioning And Proving Of Cnc Vertical Turning Lathe Machine On Turnkey Basis With Leading Parameters As Per Schedule-I Of Annexure Specification Appended With Tender. It Shall Include All The Concomitant Accessories/Equpments (Clause 4.2 Of Section Iv) As Detailed In The Specification And Other Concomitant Accessories/Equipment, Which The Manufacturer Consi Ders Essential To Make The Machine Fully Operational, When Installed And Commissioned. It Shall Also Include I Nstallation And Commissioning Of Related Equipment (Clause 12 Of Section V), Training Of Personnel In Operati On And Maintenance Of Machine (Clause 10 Of Section V) And Supply Of Technical Documentation (Clause 4 O Section V). It Shall Also Include Preventive Maintenance During Warranty Period As Per Clause No. 16 Of Secti On V Of Specification Attached This Tender. The Machine Shall Have The Provisions Of Industrial 4.0. The Firm N Eeds To Provide Inbuilt Hardware (For Industrial 4.0) Capable Of Communicating Vital Parameters For Operation S And Preventive Maintenance Of The Machine, Moreover, The Firm Will Connect The Machine To The Existing In Dustry 4.0 System At Carriage & Wagon Workshop, Bikaner. ] , Camc For 5 Years After Completion Of 2 Years Warranty Period From The Date Of Commissioning & Proving Out Of Machine By Supplier. The Details Of Camc As Defined In Clause 17 Of Section V Of Specificati Ons Appended With This Tender. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wheel/Bkn, Nwr Rajasthan 1.00 Numbers 3 6590188100302 Optional Non Stock --- No Tpi Agency Inr (Cnc) Spares (Y) A Set Of Optional Accessories As Per Para 4.3 Of Section Iv Of Specification Appended With The T Ender. Bidders Are Required To Attach The Price Break Up Of These Accessories In Pdf File Along With Submitted Bid. ] Consignee Sse/Wheel/Bkn, Nwr Rajasthan 1.00 Numbers Inspection Details Stage Inspection Not Required Page 1 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 4 6590188100303 Optional Non Stock --- No Tpi Agency Inr (Cnc) Spares (Y) Consumables:- Defined At Clause 6 Of Section V Respectively Of Specification Appended With Te Nder. The List Of Consumable Spares Shall Be Furnished And Quoted Along With Their Unit Rates. Consumables S Hall Be Supplied Along With The Machine Or As Per Agreed Time Table, If Ordered. Bidders Are Required To Attac H The Price Break Up To These Consumables In Pdf File Along With Submitted Bid. ] Consignee Sse/Wheel/Bkn, Nwr Rajasthan 1.00 Numbers Inspection Details Stage Inspection Not Required 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 0 Days Of Issue Of Contract, Completion Delivery Should Be : Within 517 Days Thereafter Completed With In 517 Days From Issue Of Loa Which Will Include Supply, Installation And Commissioning Work As Per Delivery Schedule Chart As Per Clause 7 Of Section Iv Of Specification Appended With This Tender. Payment Terms S.No Description Payment Terms 1 Payment Terms For Basic Machine And Accomapnied Supply Items(Spares Etc.): The Standard Payment Terms Subject To Recoveries, If Any, By Way Of Liquidated Damages Will Be As Under: (A) 80% Payment Will Be Made On Receipt Of The Material Duly Pre Inspected And Receipted At Site By The Consignee In Good Condition. (B) I) Balance 20% Payment Will Be Made On Furnishing A Bank Guarantee For An Amount Equal To 10% Of The Contract Value, Fully Indemnifying The Purchaser Against All Losses Incurred By The Purchaser During The Warranty Period Within 30 Days Of The Receipt Of Bill Alongwith Proving Test Certiï¬Cate After Successful Completion Of Proving Test In Which The Machine Performance Would Have Been Demonstrated By The Supplier Or His Agent After Its Commissioning At The Consignee Premises. Where, However, The Installation And Commissioning Of The Machine Is Delayed Or Put Off Beyond 90 Days Of The Receipt Of The Goods At The Ultimate Destination Due To Express Written Instructions Of The Purchaser/Consignee, The Balance 20% Payment Shall Be Released To The Supplier On His Furnishing The Necessary Bank Guarantee Of Equal Amount I.E. Balance 20% Valid For The Period As Asked By The Purchaser.Ii) The Bank Guarantee As Mentioned Above Should Be From A Nationalised Indian Bank/Schedule Commercial Bank In India. 2 Payment Terms For Turnkey Charges: As Per Ptc Of Specification Appended With This Tender. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 Irs Conditions Of Contract: The Contract Shall Be Governed By Latest Version (Along With All Correction Slips) Of Irs Conditions Of Contract, And All Other Terms And Conditions Incorporated In The Tender Documents. Page 2 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 2 The Contract Shall Be Governed By The Conditions Of Tender Inquiry , Irs Conditions Of Contract, Speciï¬Cations Attached With This Tender. The Tender Inquiry Conditions, Speciï¬Cations & Special Conditions Of Contract (If Attached) Will Have Precedence Over The Irs Conditions And Conditions Speciï¬Ed In Tender Annexures. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bulk Or Full Order Will Be Placed On Normal Applicable To Yes Yes Allowed Manufacturers Or Its Authorized Agents Who All Bidders (Mandatory) Are Either Registered With Railway For Tendered Item Or Who Has Successfully Supplied Three Numbers (Supply Here Interprets To Supply, Installation & Commissioning Being M&P Item) Tendered Or Similar Item* ,In India,To Zonal Railway /Pu/Core/Psu/Other Govt. Department/ Company Having Average Annual Turnover** Of Rs.100 Cr & Above In Last ϬVe ϬNancial Year And Current ϬNancial Year Up To Date Of Tender Opening. *Deï¬Nition Of Similarity:- Cnc Vertical Turning Lathe With Table Diameter Of 1200Mm Or Bigger. **Documentary Evidence In The Form Of A Certiï¬Cate From The Chartered Accountant Indicating The Turnover Details For The Relevant Period Shall Be Uploaded With The Bid. Page 3 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 2 Performance Criteria: Normal Applicable To Yes Yes Allowed 1. The Tenderer Shall, In Their OffEr, Submit All Bidders (Mandatory) Satisfactory Performance Certiï¬Cate Of At Least 01 No. Of Such Machine (Which Are Counted For The Purpose Of Supply Above). The Machine Covered By These Certiï¬Cates Must Have Worked Satisfactorily For At Least One Year From The Date Of Commissioning As On The Original Date Of Closing Of Tender. The Certiï¬Cate Shall Not Be Older Than One Year From The Original Date Of Closing Of Tender. The Performance Certiï¬Cate Issued After Original Date Of Closing Of Tender (In Cases Where Tender Closing Date Has Been Extended) Are Also Acceptable However The Machine Must Have Completed One Year Of Satisfactory Working After Date Of Commissioning As On Original Date Of Closing Of Tender. To This EffEct, The Performance Certiï¬Cate Submitted By The Tenderer Shall Have Been Issued By The Actual End User Organization Of The Machine (Oï¬Ƒcer Level In Case Of Railway), With Their Clear Signature And Address Therein, In Whose Premises The Machine Is Installed And Commissioned.Specification. 2. All Necessary Information/ Supporting Documents Required For Establishing Performance Eligibility Criteria, As Proof Of Past Supply Credentials Shall Be Submitted By The Bidder Along With Original OffEr Itself And The Onus To Prove Successful Supply And Commissioning In The Stipulated Time Frame Lies On The Bidder. In Case No Information Or Incomplete Information Is Furnished By The Bidder Or Offers Submitting Credential Orders Unaccompanied With Proof Of Supply, Commissioning And Installation, Their OffEr Will Be Liable To Be Ignored. 3 In Case The Tenderer Is An Agent Of The Normal Applicable To Yes Yes Not Allowed Manufacturer, They Should Clearly Indicate All Bidders The Same And Also Enclose Tender Speciï¬C Current Authorization Certiï¬Cate From The Manufacturer To This EffEct On The Letter Head Of Manufacturer And Also Mention The Place Where The Equipment Will Be OffEred For Pre Inspection Before Dispatch. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 4 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 1 Micro And Small Enterprises ϬRms In Order Normal Applicable To No No Not Allowed To Avail Themselves Of Beneï¬Ts And All Bidders Preferential Treatments, The Mses Must Be Registered With Any Of The Following: - (A) Udyam (Udyam Registration Certiï¬Cate). (B) Udyog Aadhar Memorandum (Note :- Terminal Date For Consideration Of This Certiï¬Cate Was Till 30.06.2022 Or As Extended By Ministry Of Micro, Small & Medium Enterprises From Time To Time. Thus This Certiï¬Cate (Udyog Aadhar Memorandum) Can Only Be Considered If The Above Terminal Date Is Further Extended Beyond 30.06.2022). Mses Registered With Above Agency/Agencies Must Attach (In The Template - Attach Documents On Techno-Commercial Bid Details Form, As Scanned Copy In Pdf Format) Their Current & Valid Registration Certiï¬Cate Along With Their OffEr. Other Conditions Shall Be As Per Para 4 Of Section-I Of Nwr Tender Condition Document 2 In Case Of Tender Item Cannot Be Split Or Normal Applicable To No No Not Allowed Divided, Etc. The Mse Quoting A Price Within All Bidders The Band L1+15% May Be Awarded For Full/Complete Supply Of Total Tendered Value To Mse, Considering The Spirit Of The Policy For Enhancing Govt. Procurement From Mses. Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Emd Condition: As Per Clause 3 Of Section-I Normal Applicable To No No Not Allowed Of Nwr Sbd Tender Conditions All Bidders 2 Ca Certiï¬Cate: In Cases Of Procurement For Normal Applicable To No No Not Allowed A Value In Excess Of Rs. 10 Crores, The All Bidders Class-I Local Supplier/ Class Ii Local Supplier Shall Be Required To Provide Certiï¬Cate From The Statutory Auditor Or Cost Auditor Of The Company (In The Case Of Companies) Or From A Practicing Cost Accountant Or Practicing Chartered Accountant (In Respect Of Suppliers Other Than Companies) Giving The Percentage Of Local Content. The Certiï¬Cate Should Have Valid Udin Mentioned In Certificate. 3 1.Bidders Have To Quote Rates Of Each Of Normal Applicable To No No Not Allowed The Mentioned Items Individually In Pdf ϬLe All Bidders Such As Concomitant Accessories, Any Other Concomitant Accessories, Spares For Two Year Normal Operation, Concomitant Works Etc (Whichever Applicable ) And The Quoted Cost Will Be Included For The Purpose Of Inter-Se Ranking And Commercial Evaluation Except For Optional Services/Spares/Consumable & Camc. 2. The Price Break Up Quoted By ϬRm Will Be Binding For The Purpose Of Post Contract Management/ Entering Into Separate Contract Based On This Contract. 4 Sd Condition: Security Deposit Will Be 5% Of Normal Applicable To No No Not Allowed The Contract Value . Other Conditions Of Sd All Bidders Will Be As Per Clause 12 Of Section-Ii Of Nwr Sbd Tender Conditions Page 5 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 5 All The Bidders/Tenders Should Ensure That Normal Applicable To No No Not Allowed They Are Gst Compliant And Their Quoted All Bidders Tax Structure/Rates Are As Per Gst Law. In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst/Utgst/Sgstact, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. 6 Tenderer Should Mention In Their OffEr: - 1. Normal Applicable To No No Allowed Name Of Manufacture With Complete All Bidders (Optional) Address. 2. Place Of Inspection Be Indicated With Complete Address, Option For Inspections At Godowns/Outstation/Multiple Places Be Strictly Avoided, And Preferably Be Permitted Only At Manufacturers Place. 7 Warranty Obligations: 1. The Warranty Normal Applicable To No No Not Allowed Obligations Shall Stand For 2 Years From All Bidders Installation, Commissioning And Proving Out Of Machine By Supplier (Details Shall Be Referred At Clause 7 Of Section Iv And Clause 16 Of Section V Of Speciï¬Cation Appended With The Tender. 8 Please Enter The Percentage Of Local Normal Applicable To No No Not Allowed Content In The Material Being OffEred. All Bidders Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. 9 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Scope Of Supply: The Scope Of Supply Shall Normal Applicable To No No Not Allowed Include Design, Manufacture, Supply, All Bidders Installation, Testing, Commissioning And Proving Of Machine On Turnkey Basis. It Shall Include All The Concomitant Accessories/Equipment%U2019s As Detailed In The Speciï¬Cation And Other Concomitant Accessories/ Equipment, Which The Manufacturer Considers Essential To Make The Machine Fully Operational, When Installed And Commissioned. It Shall Also Include Installation And Commissioning Of Related Equipment, Training Of Personnel In Operation And Maintenance Of Machine (Clause 10 Of Section V) And Supply Of Technical Documentation. 2 For ϬRms Not Seeking/Eligible For Earnest Normal Applicable To No No Not Allowed Money Exemption, Earnest Money As All Bidders Stipulated In The Notice For Invitation Of Tenders (Nit) Will Have To Be Paid Only Online Through Payment Gateway Link. No Other Mode Of Payment For Emd Is Acceptable. Other Conditions Page 6 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 The Machine Shall Be Inspected And Tested Normal Applicable To No No Not Allowed During DiffErent Stages Of Its Manufacture All Bidders Starting From Raw Material Till The Completion Of Machine, By The Purchaser Or His Authorized Representative At The Suppliers Or His Sub-Suppliers Works. The Quality Assurance Plan As Per Annexure-I Of Section Vi Shall Be Submitted Along With The Bid. The Bidder Must Submit The Exhaustive Qap Incorporating The Tests As Given In Annexure-I Along With Other Tests /Stage Inspection As Followed By Them. 2 The Detailed Norms Regarding Insepction Normal Applicable To No No Not Allowed Shall Be Referred At Clause 9 Of Secton V Of All Bidders Specification Appended With This Tender. 3 Inspection Clause- 1. Inspection -Third Party Normal Applicable To No No Not Allowed Inspection (Tpi) For Indigenous All Bidders Product/Make . 2. Third Party Inspection Against Gc/Tc May Be Considered For Foreign Make/Brands, Indian Vendors Supplying Foreign Goods Or Goods Having Large Foreign Content. Documentary Evidence Will Be Required To Be Produced At The Time Of Inspection For The Part/Whole Assembly Which Has Been Claimed As Foreign Part/Whole Assembly. 4 F.O.R.:- Destination Normal Applicable To No No Not Allowed All Bidders 5 Service Facility In India And Techncial Normal Applicable To No No Not Allowed Support: The Tenderer Will Clearly Spell Out All Bidders In The OffEr The Facilities Available With Him Or His Agent For Providing Adequate After- Sales Service In India During Warranty Period . The Complete Details Such As Organization For After Sales Service, Availability Of Technically Competent Engineers And Warehousing Facilities For Spares Should Be Clearly Indicated. Bidders Not OffEring Complete Servicing/Repair Facilities In India To Ensure Quick Response To Maintenance/ Servicing Calls Are Not Likely To Be Considered. Detailed Condition As Para Clause 13 Of Section V Of Specification Appended With The Tender 6 Purchaser Reserves The Right To Verify At Normal Applicable To No No Not Allowed Any Time, The Details Submitted By The All Bidders Bidder By Actual Site Visit. If The Information Furnished In The Bid Is Found To Be Incorrect During Veriï¬Cation, The Bid Shall Be Considered Invalid And Their Emd Shall Be Forfeited, And Necessary Action Will Be Initiated Including Suspending Business With North Western Railway. It Is The Bidders Responsibility To Ensure That The Information In The OffEr Remains Unchanged For The Validity Of The OffEr And Must Be Verifiable During This Period. 7 This Tender Complies With Public Normal Applicable To No No Not Allowed Procurement Policy Order,2017(Along With All Bidders Revisions/Addendums/Additions Issued From Time To Time ) With Respect To Make In India Policy. 8 The Delivery Speciï¬Ed In Tender Schedule Normal Applicable To No No Not Allowed Covers The Complete Time Period Required All Bidders For Supply, Installation & Commisssioning. 9 Foundation And Related Drawing, Approvals Normal Applicable To No No Not Allowed Of Ga, Foundation And Related Drawings: As All Bidders Per Clause 11 Of Section V Of Speciï¬Cation Appended With The Tender. Page 7 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 10 As Per The Section Iv Clause 2.2. I.E Leading Normal Applicable To Yes Yes Not Allowed Parameters (Schedule-I): All Bidders 2.2.1 Major Parameters(Note: No Deviation Is Permitted In Major Parameters.The Bidder Should Indicate The Actual Parameters Offered). 11 The Bidder Shall Furnish Along With The OffEr Normal Applicable To No No Not Allowed A List Of All Critical Items/ Sub- Assemblies All Bidders Which Are Bought Out By The Bidder And Proposed To Be Used, Along With The Manufacturers Name, Brand Model Etc.The Manufacturer Shall Produce Invoices Of Bought Out Items/Sub-Assemblies To Ensure Genuineness Of Such Products / Veriï¬Cation By The Inspecting Agency. 12 Training:- Contractor Shall Train The Railway Normal Applicable To Yes Yes Not Allowed Staff Regarding Operation And Maintenance All Bidders Of Equipment During Commissioning Of M&P.(Detailed Training Norms Shall Be Referred At Clause 10 Of Section V Of Specification Appended With This Tender) 13 As Per The Section C Clause 13.0 Service Normal Applicable To Yes Yes Allowed Facility In India And Technical All Bidders (Mandatory) Support:The Complete Details Such As Organization For After Sales Service, Availability Of Technically Competent Engineers And Warehousing Facilities For Spares Should Be Clearly Indicated. Bidders Not OffEring Complete Servicing/Repair Facilities In India To Ensure Quick Response To Maintenance/Servicing Calls Are Not Likely To Be Considered. Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case The Clause Of Nit Instructs For Normal Applicable To No No Not Allowed Submission Of Requisite Document And The All Bidders Document Uploading Tab Corresponding To That Clause Has Been Deï¬Ned As -Not Allowed/Allowed(Optional) Shall Be Ignored And The Bidders Are Instructed To Upload The Requisite Document Invariably Along With Submitted Bid At Another Available Field For Document Uploading. 2 1. The Tenderer Should Quote Camc Rates Normal Applicable To No No Not Allowed Separately At The Designated ϬElds For The All Bidders Period Of 5 Years 2. For Tenders Containing Camc, The Charges Of Camc For ϬVe Years Would Also Be Included In The For Destination Price Quoted For M&P For The Purpose Of Comparative Evaluation Of Offer. 3.Tenderers Shall Note That Railway Reserves The Right To Settle And Place Purchase Order For Tendered Item With Or Without Camc Decision Of Railways Shall Be Final In This Regard. 4. With Reference To Post Contract Maintenance, This Tender Has Been Ϭ‚Oated Exclusively For Camc Requirement . Amc/Camc If Speciï¬Ed Elsewhere In Tender Document /Annexures Shall Be Read As Camc And Prices Are To Be Quoted Accordingly. 3 Technical Speciï¬Cations For Cnc Vertical Normal Applicable To No No Not Allowed Turning Lathe Shall Be As Per The All Bidders Specification Appended With This Tender. Page 8 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 4 The Section I, Ii & Iii (Sbd Nwr Document) Normal Applicable To No No Not Allowed Are Meant For Generalised Application All Bidders Wherein The Situation/Condition Has Been Not Deï¬Ned Elsewhere In Electronic Sor And Speciï¬Cation Appended With The Tender. 5 For Condition Speciï¬Ed In Electronic Sor, Normal Applicable To No No Not Allowed The Condition Speciï¬Ed In Elctronic Sor Will All Bidders Have Precedence Over Conditions Speciï¬Ed Elsewhere In Nit I.E Annexures Appended With The Tender. For Conditions Not Speciï¬Ed In Electronic Sor, The Conditions Specified In Annexures Will Prevail. 6 Delivery Schedule Chart: As Per Clause 7 Of Normal Applicable To No No Not Allowed Section Iv Of Speciï¬Cation Appended With All Bidders This Tender. 7 For Traders, Non Submission/Uploading Of Normal Applicable To No No Not Allowed Valid Oem Authorization Letter Will Make All Bidders Their OffEr Invalid And OffEr Will Be Summarily Rejected. 8 The Price Break Up Quoted By ϬRm Will Be Normal Applicable To No No Not Allowed Binding For The Purpose Of Post Contract All Bidders Management/Entering Into Separate Contract Based On This Contract. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Whenever, Standard Technical Requirement Normal Applicable To No No Not Allowed Document Has Been Appended With The All Bidders Tender Document, The Participants Are Required To Conduct Comprehensive Study Of The Technical Speciï¬Cations And Deviations If Any, Shall Be Indicated In The Designated Data Entry ϬEld Of Ireps Bid Submission Form. Technical Deviations Quoted Elsewhere Are Liable To Be Ignored. 2 No Deviation Shall Be Permitted Against Normal Applicable To Yes Yes Not Allowed Leading Parameters Speciï¬Ed At Clause 2.2 All Bidders Of Section Iv Of Specification Appended With This Tender. Deviations Other Than The Leading Parameters, For Deviation If Any, (Other Than Leading/ Major Parameters Of Machine For Which No Deviations Shall Be Permissible) Bidders Are Required To Quote The Same Indicating Clause No. And Relevant Documents In The Statement For Commercial And Technical Deviations. Any Deviation Quoted Elsewhere Shall Not Be Considered And It Will Be Presumed That The Bid Meets/Complies The Tender Conditions. Bidders Need Not Quote Clause Wise Comments Against Various Clause Of Bid Document And May Only Quote Deviations Except For The Detail As Per Technical Bid Annexure-A Of Section Vi If Any, In The Respective Deviation Statement (This Condition Will Supersede The Corresponding Conditions Mentioned Elsewhere In Tender Documents). 3 Bidders Are Required To Furnish Details Of Normal Applicable To No No Allowed Bought Out Items As Per Clause 14 Of All Bidders (Optional) Section V Of Specification Appended With This Tender. Page 9 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 4 Firm Shall Conduct Exhaustive Study Of The Normal Applicable To No No Not Allowed Annexures Present In The Annexure- All Bidders Speciï¬Cation And Shall Submit Duly Signed Annexures Which Are Required At Bid Submission Stage. The Proformos Meant For Post Contract Stage May Be Ignored At Current Stage And Shall Be Utilized For Post Contract Activities. 5 List Of Components To Be Loaded On The Normal Applicable To No No Not Allowed Machine: As Per Annexure F Present In All Bidders Annexure- Speciï¬Cation Appended With The Tender. 6 Railway Reserves The Right To Modify The Normal Applicable To No No Not Allowed Requirement Regarding Staged Inspection As All Bidders Per Applicable Str/Speciï¬Cations At Later Stage. 7 The Bidder Must Submit The Technical OffEr Normal Applicable To No No Not Allowed As Per The Format Given In Annexure-A In All Bidders Section - Vi. All The Information As Asked For, In The Format Must Be Given Accordingly E.G Wherever A Parametric Value Is Asked It Should Be Furnished, If A Write Up Is Asked For This Should Be Provided And If A Brochure Or Drawing Or Sketch Is Expected This Should Be Provided. In Case Of Incomplete/Sketchy/Illegible Information, The Technical OffEr Will Be Considered As Incomplete And Liable To Be Rejected. 8 Proving Test: As Per Clause 2.5 & 2.6 Of Normal Applicable To No No Not Allowed Section Iv Of Speciï¬Cation Appended With All Bidders This Tender. Undertakings S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Participation In Tender Will Be Considered Normal Applicable To No No Not Allowed That Following Certiï¬Cate Has Been Signed All Bidders By All The Bidders Unless Otherwise Speciï¬Cally Mentioned In Its OffEr I Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India; I Certify That This Bidder Is Not From Such A Country Or, If From Such A Country, Has Been Registered With The Competent Authority, I Hereby Certify That This Bidder Fulï¬Lls All Requirements In This Regard And Is Eligible To Be Considered. Note: Any False Declaration And Non-Compliance Of The Above Would Be A Ground For Immediate Termination Of The Contract And Further Legal Action In Accordance With The Law. 2 Participating ϬRm Undertakes That Quoted Normal Applicable To No No Not Allowed Technical Deviation With Respect To All Bidders Quantity/Parameter/Any Other Technical Speciï¬Cation Will Not AffEct The Smooth Operation, Functionality And Reliability Of The Equipment 3 Firm Undertakes That Careful Examination Normal Applicable To No No Not Allowed The Contents Of Po/Loa ( Whichever Is All Bidders Issued ϬRst) Will Be Conducted By ϬRm Within Ten Days Of The Issue Date Of Loa/Po And In Case Any Discrepancy Noted, Shall Make A Representation Within Ten Days Of The Date Of Po/Loa. Any Representation Thereafter For Dp Re- ϬXation On This Ground Will Not Be Entertained. 4 The Participating Firm Undertakes That It Normal Applicable To No No Not Allowed Has Been Not Debarred/Black All Bidders Listed/Suspended/Banned By Railways For Business Purpose. Page 10 Of 11 Run Date/Time: 07/05/2025 17:52:41Stores/North Western Rly Tender Document Tender No 65245036 Closing Date/Time 25/06/2025 14:25 5 We Hereby Declare That In Quoting The Normal Applicable To No No Not Allowed Above Price, We Have Taken Into Account All Bidders The Full EffEct Of Input Tax Credit Available Under Gst. We Further Agree To Pass On Any ϬNancial Gain/Beneï¬T As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser (Railway) Accordingly. We Also Undertaken That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. The Contractor Shall Be Gst Complaint And Claim The Applicable Gst In Their Bills, Which Will Be Paid By The Railways 6. Documents Attached With Tender S.No. Document Name Document Description 1 4390879.Pdf Irs Condition 2 5318947.Pdf Specification 3 5317886.Pdf Nwr Sbd The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm2 ( Rajendra Solanki ) , A Set Of Optional Accessories As Per Para 4.3 Of Section Iv Of Specification Appended With The T Ender. Bidders Are Required To Attach The Price Break Up Of These Accessories In Pdf File Along With Submitted Bid. ] , Consumables:- Defined At Clause 6 Of Section V Respectively Of Specification Appended With Te Nder. The List Of Consumable Spares Shall Be Furnished And Quoted Along With Their Unit Rates. Consumables S Hall Be Supplied Along With The Machine Or As Per Agreed Time Table, If Ordered. Bidders Are Required To Attac H The Price Break Up To These Consumables In Pdf File Along With Submitted Bid. ]
Contract Date: Jun 11, 2026 Contract Value : 2.22 Crore
Government Departments No of Bidders 1
32.
Civil Aviation #11203251 AOC
Bids Are invited for Product 1 - Supply Of Dual Server Gateway Based Ip Pbx System In Raid 1 Storage Configuration. , Product 2 - Supply Of Executive Ip Phones With 2 Way Speaker Phone , Product 3 - Supply Of Poe Based Ip Phones , Product 4 - Supply Of 24 Port L2 Plus Managed Poe/Poe+ Switch With Fully Loaded Sfp Modules Single Mode Transceiver. , Product 5 - Supply Of 16 Port L2 Plus Managed Poe/Poe+ Switch With Fully Loaded Sfp Modules Single Mode Transceiver. , Product - Supply Of 8 Port L2 Plus Managed Poe/Poe+ Switch With Fully Loaded Sfp Modules Single Mode Transceiver. , Product - Supply Of 24 Core Core Armoured Single Mode Ofc Cable , Product - Sitc Of Licensed (Perpetual) Nms Software (Software For Monitoring The Health Of All Ip Devices Of The Network On Single Window). , Product - Supply Of Corded Analog Phone With Cli , Product - Sitc Of Management Platform Inclusive Of Management Software Of Epbax System With Perpetual License , Product - Supply Of Licensed (Perpetual) Recording Application (To Be Played At Operator Console) , Product - Supply Of Pc Based Ip Operator Console In Raid 1 Storage Configuration With Licensed Version Of Software(Latest) , Product - Supply Of Laptop Based Ip Operator Console With Licensed Version Os And Ms Office (Latest) , Product - Supply Of Cat 6A Cable Industrial Grade Including Capping, Casing, Conduiting Fasteners With All Materials. , Product - Supply Of Cat 6A Utp Patch Cord 3 Meter Each. , Product - Supply Of 3 Core Power Cable 2.5Mm Each Core. , Product - Supply Of Intermediate Distribution Frame Idf For 100 Pairs , Product - Supply Of Intermediate Distribution Frame Idf For 20 Pairs , Product - Supply Of Intermediate Distribution Frame Idf For 200 Pairs , Product - Supply Of Intermediate Distribution Frame Idf For 400 Pairs , Product - Supply Of 0.5Mm, 50 Pair Copper Cable (Armourd). , Product - Supply Surge Protection Device For Idf Krone Type (10 Pair In Each Krone). , Product - Supply Of 0.5 Mm, 20 Pairs Telephon
Contract Date: Ref. Documents Contract Value : 1.39 Crore
Boards / Undertakings / PSU No of Bidders 6
Maharashtra View Result →
33.
Educational and Research Institute #11197867 Price Bid
Tender for Equipment For Internet Of Things Lab (Common), Iot (It) , Price Schedule For Iot Lab (Commom) (Sheet 1) , Price Schedule For Iot Lab (It) (Sheet 2) , Price Schedule For Services (Sheet 3) , Sensor Trainer Lab , Iot Development Platform , Application Of Iot In Smart City , Application Of Iot In Smart Agriculture , Application Of Iot In Healthcare , Iot Daq And Protocol Convertor , Iot Edge Computing Device , Field Interface And Protocol Simulation Kit , Ai Development Platform , Ai Development Platform For Sound & Motion Study , Embedded And Iot Workbench , Iot Gateway Devices , Iot Security Devices/Software (E.G., Firewalls, Encryption Tools) , Mqtt Brokers/Servers , Raspberry Pi4 , I2c Oled Display , Lora-E5 Developmen T Kit , Frdm I.Imx91: Development Board , Arduino Uno R4 , Esp32 Developmen T Kit , Wi-Fi Routers , Wireless Communication Modules (Zigbee, Lora, Wi-Fi, Bluetooth) 5 Each , Pc With Latest Configuration , Screw Driver Set , Soil Moisture Sensor , Water Vapour Sensor , Dust Sensor , Flex Sensors , Turbidity Sensor , Load Cell Weight Sensor , Water Flow Sensor , Bmp 280 -Atmospheric Pressure Sensor , Fingerprint Sensor , Gas Sensor Mq 135 , Lm 35 Temperature Sensor , Microphone (Sound Sensor) , Tilt Sensor , Touch Sensor , Vibration Sensor , Ultrasonic Sensor Hc Sr-04 , Pir Motion Sensor , Joystick Sensor , Sensor Trainer Lab , Iot Development Platform , Application Of Iot In Smart City , Application Of Iot In Smart Agriculture , Application Of Iot In Healthcare , Iot Daq And Protocol Convertor , Iot Edge Computing Device , Cloud Based Scada , Field Interface And Protocol Simulation Kit , Ai Development Platform , Ai Development Platform For Sound & Motion Study , Iot Workbench , Embedded And Iot Workbench , Training For Asu Instructor, Faculty And Asup Officials Or Any Others Persons As Nominated By Asup On All Items Under Scope Of Supply For Minimum 15 Days After Delivery And One More Training For 1 Week After 3 Months At Field Including Co
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
34.
Heavy Industries and Public Enterprises #11176301 Technical Bid
Tender For Supply Of Material , Fsk Gateway For Loco
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 2,310
Statutory Bodies & Commissions/Committees No of Bidders 3
45.
Defence #11106751 Technical Bid
Tender For Development, Installation And Commission Of Ground Segment Hub For Voice And Data Communication; A1 9.0 Mitr (typical) C-band Antenna System (k) Antenna Mount, Structural, Mechanical Motorized Drive Systems along with motors, Encoders. Limit Switches for Az El and Feed (Polj movement 4-Port Feed System Qty 01 No (m)Around 100 Mtr Civil Trench with covering B cable hanger for interconnecting Antenna with Earth Station Main Trench-Qty-01 No in) 01 no. of Aritenna Lightning Protection 801 no. of Antenna Grounding (0) installation of 9.0Mtr C-band Antenna System and interface Accessories A2 AS Antenna Control Unit (ACU) along with 100 Mt control cable Beacon Tracking Receiver A4 Dehydrator 8.5 32 KWatt C-band High-Power Power Amplifier with Built-In redundancy along with BUC and outdoor housing 8.6 C-band LNA System with complerte 1:1 Redundancy systern along with acne 57 5G Interference Rejection Filter (Pass Band -1680 GHz to 4 200 GHz Downconverter with internal redundancy module Input Frequency (C-band)-3400-4200 GHz Output Frequency (L-Band) 950-1750 MHz Waveguide Switches, Dummy Load and Directional Coupler for Tix and Rx Chain and accessories C10 Equipment Racks along with power distribution unit comprising of (g) FRF Racks-02 Nos (1) Baseband Racks-08 Nos C11 Berver Rack-02 Nos Spectrum Analyzer (Frequency Range KHz to 26.5 GHz) 5 C. 12. Liaisoning to obtain licenses from WPC DOT and NOCC Clearance F26 40 KVA 3-Phase UPS in 1:1 Hot Standby Configuration along with accessories F:27 60 KVA 3-Phase DG Set in 1:1 Hot Standby Configuration along with accessories Milestone-4: Installation of Hub Basebar Description of Items C.13 Hardware for Multichannel Hut Modem C14 Development and porting of Baseband Firmware on Multichannel Hub Madam Hardware C.15 Hardware for Network Control Centre (NCC) with 1.1 Redundant Configuration C.16 Development and porting of software for Network Control Centre (NCC) comprising of comprising of NMS and GIS on NCC Hardware C.17 Terrestrial Interface Gateway (TIG) C. 16. Hardware for Server access unit (SAU) C.19 Development and porting of SAU software on SAU Hardware C20 NMS Client comprising of separate clients for four different Users C.21 Separate Display for NMS and GIS (2 No Eachy 022 24 port managed gigabit switch 0.24 Mini-Test Hub (Scale down version of Hub Baseband System) comprising of (K) NCC along with deployment hardware-Qty: 01 No. (1) Terrestrial Interface Gateway with support for 10 voice calls-Qty: 01 No (m)Server Access Unit with support for 10 data calls-Qty: 01 No. (n) HUR MODEMs Hardware for MST, HST and SMT network with support for 10 Qty: 01 No. (0) 24 port managed Gigabit sattch-2 Nos ... more in document
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
47.
Educational and Research Institute #11098868 AOC
Tender For Iehe Bhopal Invites Online Tender For Supply Of Sound System In The Institute , Sound System , Wall Mount Cabinet Loudspeaker General Requirements: The Loudspeaker Shall Be A Cost-Effective, 12W General-Purpose Cabinet Speaker Designed For Indoor Surface-Mount Applications. It Must Be Suitable For Both High-Quality Speech Intelligibility And Background Music Reproduction Acoustic Performance: Rated Power: 12W, With Adjustable Power Tappings At 12W, 6W, And 3W To Allow For 3 Db Step Adjustments. Sound Pressure Level (Spl): Must Provide A Maximum Special Of 102.0 Db At 6W/1M (1 Khz) And A Sensitivity Of 91.7 Db At 1W/1M (1 Khz). Frequency Range: The Effective Frequency Range Shall Be From 150 Hz To 15 Khz. Opening Angles: Horizontal: 184° (1 Khz) / 86° (4 Khz). Vertical: 66° (1 Khz) / 58° (4 Khz). Electrical Specifications: Input Voltage: Designed For 100 V Line Systems. Rated Impedance: 833 Ohms. Connection: Shall Feature A 4-Pole Push-In Terminal Block On The Rear Panel For Easy On-Site Wiring And Power Tapping. Durability: The Unit Must Be Tested For 100 Hours Of Continuous Operation At Rated Power In Accordance With Iec 268-5 Standards. Mechanical Construction Enclosure Material: The Main Body Shall Be Constructed From Solid Mdf (Medium Density Fiberboard) Covered In Durable, Easy-To-Clean Black Vinyl. Front Grille: The Front Shall Be Abs Plastic Covered With A Fine Woven Cloth In Matching Black. Baffle Design: Shall Feature An Angled Front Baffle To Optimize Sound Distribution Within The Listening Area. Mounting: The Rear Panel Must Include Three Keyholes For Quick And Secure Wall Mounting. Dimensions: 445 Mm X 151 Mm X 150 Mm / 111 Mm Environmental Limits: Operating Temperature: -5 °C To +55 °C, Storage Temperature: -40 °C To +70 °C , Wireless Microphone System General System Requirements: Classification: The System Shall Be An Entry-Level Professional Wireless Microphone System Designed For Ruggedness And Ease Of Use In Daily Operations. Ease Of Setup: The System Must Include A One-Button Automatic Frequency Scanning Function To Identify The Clearest Available Channel. Transmitter Synchronization Shall Be Achieved Via An Infrared Data Link To Ensure Error-Free Setup. Frequency Management: The System Shall Provide 32 Preset Channels, With Compatible Groups Of Eight Channels For Simultaneous Multi-Channel Use. Operating Bands: The System Shall Be Available In Multiple Rf Frequency Bands, Including: A Band: 618-634 Mhz. B Band: 678-694 Mhz. C Band: 516-532 Mhz. E Band: 850-865 Mhz. Receiver Specifications Type: Synthesized Pll With True Antenna Diversity To Ensure Stable Rf Reception. Chassis: The Receiver Must Feature A True Rack-Mountable Metal Chassis Suitable For Professional Installation. Rf Performance: Sensitivity: 1.0 Μv For 12 Db Sinad. Image Rejection: Greater Than 55 Db. Audio Outputs: Balanced Output: 20 Dbv (Max @ 40 Khz Deviation). Unbalanced Output: Adjustable From 8 Mv To 0.755V Rms. Display: Front-Panel Backlit Lcd Displaying Channel, Frequency, And Battery Status. Handheld Transmitter Construction: The Transmitter Shall Feature A Rugged Metal Body Designed To Withstand The Rigors Of Daily Use. Microphone Capsule: Equipped With A Cardioid Dynamic Capsule (Pl22) For Effective Feedback Control And Ambient Noise Rejection. Battery Life: Must Operate For A Minimum Of 14 Hours Using Two Aa Alkaline Batteries. User Interface: Features A Backlit Lcd Display And A Dedicated Mute Function To Protect The Audio Channel. Bodypack Transmitter Construction: Compact And Rugged Metal Enclosure. Input Connector: Industry-Standard Ta4F Connector For Compatibility With Various Lapel Or Headworn Microphones. Antenna: Flexible External 1/4 Wave Antenna. Acoustic & Environmental Performance System Frequency Response: 80 Hz - 18 Khz ± 2 Db Signal-To-Noise Ratio: 100 Db A-Weighted Total Harmonic Distortion: 1.0%, 0.4% Typical (Ref 1 Khz, 40 Khz Deviation) , Professional Gooseneck Microphone General Requirements: The Microphone Shall Be A Professional-Grade, High-Quality Electret Condenser Gooseneck Microphone Designed For Public Address Applications Such As Lecterns, Podiums, And Open Conferences. It Must Feature A Sleek, Slender, And Unobtrusive Design To Maintain A Clear Line Of Sight For The User. Acoustic & Technical Performance Transducer Type: Electret Condenser. Polar Pattern: Unidirectional (Cardioid) To Ensure High Front-To-Back Rejection, Providing More Gain Before Feedback. Frequency Response: Wide Range From 20 Hz To 18,000 Hz. Sensitivity: 7.5Mv/Pa Power Requirement: Operable Via A Dc Power Source Ranging From 1.5V To 9V. Mechanical Specifications Overall Length: 585 Mm (Approximately 23 Inches) Output Connector: Built-In 3-Pin Xlr Male Socket For Secure And Standard Professional Connectivity. Optional Accessories (Compatibility) To Ensure System Flexibility, The Microphone Must Be Compatible With The Following Manufacturer-Specific Accessories: Microphone Base: A Sturdy, Heavy-Duty Die-Cast Aluminium Base With An Integrated On/Off Switch, Led Indicator, And Built-In Housing For 2 Times 1.5V Um-3 Aa Cells To Power The Condenser Element. Mic Stand Adaptor: A Rugged Aluminium Die-Cast Body With A Female Xlr Connector For Direct Mounting And A Male Xlr Bottom Connector For Cable Attachment. It Must Include A 10-Meter Shielded Cable And A Threaded Brass Ferrule 5/8 27 Tpi For Standard Stand Mounting. , Mixer Amplifier General System Requirements Type: The Unit Shall Be A Professional 120W Mixer Amplifier With Integrated Usb And Bluetooth Capabilities, Designed For Public Address And Background Music Applications. User Interface: The Amplifier Shall Feature A Simplified User Interface With Preferred Setting Indicators (Colored Pins) For All Front-Panel Knobs To Ensure Ease Of Operation For Non-Technical Users. It Must Include An Led Vu Meter For Visual Output Level Indication And A 6.3 Mm Headphone Socket For Monitoring The Mixer Output. Reliability: The Unit Shall Have No Moving Parts (Such As Hard Drives) To Ensure Long-Term Operational Reliability. Audio Inputs And Media Source Microphone/Line Inputs: Four (4) Balanced Inputs, Switchable Between Microphone And Line Level Sensitivity. Switchable Phantom Power Must Be Available To Support Condenser Microphones. Priority Handling: Input 1 Shall Have The Capability To Take Priority Over All Other Inputs Via Contact Closure (Push-To-Talk) And Include An Optional 2-Tone Chime To Precede Announcements. Music Source: Integrated Media Player: Must Support Playback Of Mp3 And Wav Files (From 32 Kbit/S) Via A Usb Pen Drive (Up To 32Gb Capacity). Wireless Streaming: Built-In Bluetooth For High-Quality Audio Streaming From Mobile Devices. Remote Control: The Unit Must Be Supplied With An Ir Remote Control For The Integrated Music Source. Aux Input: A Separate Stereo Cinch Input, Internally Converted To Mono, With A Sensitivity Of 200 Mv To 300 Mv. Audio Performance And Output Output Power: 120W Rated Output Power. Loudspeaker Outputs: Constant Voltage: 100 V. Low Impedance: 4-Ohm. Call-Only Output: A Dedicated 100 V Call-Only Channel For Priority-Only Areas Or 3-Wire Remote Volume Control Override. Frequency Response: 80 Hz To 18 Khz (+1/-3 Db At -10 Db Ref. Rated Output). Distortion: 1% At Rated Output Power (1 Khz). Tone Control: Dedicated Bass And Treble Controls Providing Max ± 8 Db Adjustment. System Protection: An Integrated Limiter Circuit Must Be Included To Protect The Output Stage From Signal Clipping And Overload. Insert Feature: A Pair Of Rca Cinch Connectors Shall Be Provided To Allow The Unit To Be Used As A Separate Pre-Amplifier And Power Amplifier. Mechanical And Environmental Dimensions: 100 Mm X 430 Mm X 290 Mm (Standard 19 Wide, 2U High). Mounting: Suitable For Both Stand-Alone Use And 19 Rack Mounting. Operating Temperature: -5 °C To +45 °C. Compliance: The Unit Shall Comply With Iec 62368-1 (Safety), Cispr 32 (Emc Emission), And En 55103-2 (Emc Immunity). , Mixing Console General Requirements The Mixing Console Shall Be A Compact, Versatile 6-Channel Analog Mixer Designed For A Wide Range Of Professional Audio Applications. It Must Feature High-Quality Microphone Preamplifiers And A Rugged Construction Suitable For Both Portable And Fixed Installations. Audio Inputs And Processing Input Channels: The Unit Shall Provide A Total Of 6 Line Inputs, Configured As 2 Mono And 2 Stereo Channels. Microphone Preamplifiers: The Console Shall Include 2 Microphone Inputs Featuring Discrete Class-A D-Pre Preamps With An Inverted Darlington Circuit For Superior Sound Quality. Switchable +48V Phantom Power Must Be Available For All Microphone Inputs. Channel Processing: Mono Inputs (Ch1-2) Shall Include A 26Db Pad For High-Level Sources. Each Mono Channel Shall Feature A High-Pass Filter (Hpf) Set At 80Hz With A 12Db/Octave Slope. Equalization For Mono Channels Shall Consist Of A 2-Band Eq: High (10Khz Shelving) And Low (100Hz Shelving) With Pm15 Db Adjustment. Output And Bus Section Buses: The Console Shall Feature 1 Stereo Bus. Outputs: Stereo Out: Provided Via 2 Xlr-3-32 And 2 Phone Jacks (Balanced). Headphones: One (1) Stereo Phone Jack Output With A Dedicated Level Control. Monitoring: Visual Monitoring Shall Be Provided By A 2 Times 7 Point Led Level Meter (Peak, +6, +3, 0, -3, -10, -20Db). Technical Performance Frequency Response: Pm 0.5Db From 20Hz To 20Khz (Referenced To Nominal Output Level @ 1Khz). Total Harmonic Distortion (Thd): 0.01% @ +8Dbu (20Hz To 20Khz), Gain Knob: Min 0.003% @ +18Dbu (1Khz), Gain Knob: Min Hum & Noise: Equivalent Input Noise Of -128 Dbu (Mono Input Channel, Rs: 150Ω, Gain Knob: Max) Crosstalk: -88Db @ 1Khz. Mechanical And Electrical Specifications Chassis: The Unit Shall Be Housed In A Robust, Impact-Resistant, Powder-Coated Metal Chassis. Power Supply: External Ac Adapter: Pa-130 (120V 60Hz) Or Mu18 (100-240V 50/60Hz) Or Equivalent. Power Consumption Shall Be Approximately 12W. , Indoor Wi-Fi6 Access Point General System Requirements Type: The Unit Shall Be A High-Performance, High-Speed 11Ax (Wi-Fi 6) Indoor Dual-Band Ceiling-Mounted Wireless Access Point (Ap). Standard Support: The Wireless Access Point (Ap) Shall Strictly Adhere To The Ieee 802.11Ax (Wi-Fi 6) Standard. Radio Configuration: The Unit Must Be A High-Power Industrial Ceiling-Mounted Ap Featuring 2X2 Mimo Technology For Both 2.4 Ghz And 5 Ghz Bands. Performance: The System Must Provide A Combined Wireless Data Rate Of Up To 3 Gbps To Support High-Speed Applications Such As 4K/8K Streaming And Vr/Ar. User Capacity: The System Shall Support A High Density Of Users, Accommodating Up To 128 Concurrent Users (Max 64 Users Per Band). Advanced Features: The Ap Shall Support Multi-User Mimo (Mu-Mimo), Orthogonal Frequency Division Multiple Access (Ofdma), Bss Color Bit, And Dynamic Cca-Sd For Improved Interference Management. Hardware Specifications Chipset: The Ap Shall Be Equipped With A High-Performance 4-Core Qualcomm Chipset. Ram: 512Mb Ddr3. Antenna: Integrated Internal 4X4Dbi Dual-Band Mimo Antennas. Combined Rate: A Concurrent Wireless Rate Of Up To 3000 Mbps. Physical Interfaces: 1 X 10/100/1000Mbps Wan/Poe Port. 1 X 10/100/1000Mbps Lan Port. 1 X Reset Button. Provision For A Dc2.0 12V 1.5A Power Connector. Support For Power Over Ethernet (Poe) Following Ieee 802.3Af/802.3At Standards. Thermal Management: The Unit Shall Feature A Heat Sink With A Snap-On Structure And Special Surface Coating To Optimize Heat Dissipation. Indicators: Led Status Lights For Power, Cloud Connection, Lan Speed, 2.4Ghz Status, And 5.0Ghz Status. Audio & Network Management Quality Of Service: Must Support Wmm (Wireless Multimedia Prioritization). Roaming: Support For Seamless Roaming To Ensure Uninterrupted Connectivity For Mobile Clients. Deployment: Flexible Deployment Options Including Standalone Mode, Mobile App Management, And Zero Touch Provisioning (Ztp). Network Management: Support For Vlan Settings, Cloud Access (In Gateway Mode), And System Logging. Management: Support For Remote Configuration And Management. Maintenance: Features For Backup/Restore Configuration, Factory Reset, Scheduled Reboots, And Lifetime Firmware Upgrades. Security Requirements Encryption: Must Support Wi-Fi Protected Access 3 (Wpa3) And Wired Equivalent Privacy (Wep) 64-Bit, 128-Bit, And 156-Bit. Access Control: Integrated Mac Address Filtering And Wireless Access Control To Identify Authorized Devices. Management Security: Secure Socket Layer (Ssl) For Remote Management Login And The Ability To Block Ssid Broadcasting. Environmental & Reliability Operating Limits: Working Temperature: -10°C To 55°C. Storage Temperature: -40°C To 70°C. Humidity: 5% To 95% Non-Condensing. Protection: Esd: Air ±8K, Touch 6K. Electrical Surge: Common Mode 2K, Differential Mode 1K. Power Efficiency: Maximum Power Consumption Shall Not Exceed 16 Watts. Oem Warranty And Support Local Presence: The Original Equipment Manufacturer (Oem) Must Have An Authorized Service Center Or Registered Office In Madhya Pradesh (Proof Of Gst/Msme/Registration Required With Bid). Warranty: A 2-Year On-Site Hardware Replacement Warranty Is Required, With New Hardware Provided Within 12 Hours Of A Call Lock (No Refurbished Or Repaired Products). Technical Support: On-Site Support Must Be Available Within 6 Hours Of A Request. Future Warranty & Support: Oem Must Have Warranty And Support Pack Purchase Option Before Expiry Of Warranty Period For Next Years. Service Availability: The Oem Must Provide A 24X7 1800-Series Toll-Free Number With Support Available In The Local Hindi Language. Product Life Cycle: The Quoted Product Must Have A Life Cycle Of No Less Than 5 Years From The Date Of Supply, Including Lifetime Free Firmware And Technical Assistance. Certifications: The Product Must Be Ce, Fcc, Rohs, Iec 15408 And Iso 9001. Certified. Bidder Must Have To Submit Compliance On Oem Letter Head Along With Maf. , Network Wall Mount Rack Must Have To Supply And Installation Of 15U 500X550 Network Wall Mount Rack With Glass Door And Lock With Hardware, 6 Socket Industrial Pdu 15Amp With Mcb, Cable Manager, Fan, Hardware And Etc. , Goosneck Mic Cable, Speaker Cable In Meter, Installation And Accessories Complete Job Work With Required Cables, Frpvc Conduit, Accessories, Fitting, Installation And Etc.
Contract Date: Jun 09, 2026 Contract Value : 2.02 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
50.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
TenderDetail
Loading tenders