View Bid Results For Galvanised Pole Tenders

We found 3550 Bid Results related to galvanised pole tenders. You can find Contractor details who won galvanised pole tenders along with contract details in Bid awards announcements section.

Filters
Stage
2726
512
312
Tender Publishing Platform
430
3120
State / UT
38
526
428
391
319
193
181
156
141
135
117
101
91
87
85
80
66
59
53
41
41
38
34
27
25
24
24
22
21
12
5
5
5
4
4
3
3
2
1
Contract Value
868
561
1679
434
Publish Date
9
1
0
0
0
Sector
29
1747
406
308
273
239
98
95
59
51
48
36
25
24
18
16
15
15
13
11
11
11
10
5
5
4
2
2
2
1
Ownership
6
1727
1160
530
130
2
1
Within keyword
Active filters:
Showing 1–50 of 3550 tenders matching your filters
1.
Defence #11493249 AOC
Bids Are Invited For Xlpe Cable For Working Voltage Up To And Including 1.1 Kv Marked To Is 7098 (Part 1) (Q2) , Miniature Circuit Breakers (Mcb) For Ac Operation Marked To Is/Iec 60898 (Part 1) (Q2) , Supply And Fixing On Load Change Over Switch Ss Enclosure Complete With Capacity 200 Amp, 415 Volt, 4 Pole, 50 Hz. , Supply And Fixing Sheet Metal Enclosure Spn Db Double Door Having Facility To Fix Mcb Spn As Incomer And Mcbs As Outgoing, Spn 4 Ways, Ip-43 , Supply And Fixing Sheet Metal Enclosure Tpn Db Double Door Having Facility To Fix Mcb Tpn As Incommer And Mcbs As Outgoing Tpn 4 Ways, Ip-43 , Supply And Fixing Bus Bar Chamber 100 Amp, 4 Way, 415 Volts Enclosurre Is Made From Crca Sheet Of Thickness 3.15Mm Crca Sheet Cover , Supply And Fixing Of Straight Through Epoxy Cable Joint Kit Incl Jointing Materials Making Joints Of Ug Electric Cable 1100 V Grade Nominal Cross Sectional Area Not Exc.50 Sqmm, 3.5 By 4 Core , Supply And Fixing Straight Through Epoxy Cable Joint Kit Incl Jointing Materials Making Joints Of Ug Electric Cable 1100 V Grade Cross Sectional Area 240 Sqmm To 300 Sqmm, 3.5 Core. , Supply And Fixing End Termination Epoxy Cable Joint Kit Including Jointing Materials For Making Joints Of Ug Electric Cable 1100 V Grade Nominal Cross Sectional Area 240 Sqmm To 300 Sqmm, 3.5 Core , Supply And Fixing Of Galvanised Iron Pipe 100 Mm Bore Dia Light Grade For Protection Of Ug Cable , Supply Of Digging Nad Layingg In Excavation Trenches Not Exc. 1.50 M Wide And Not Exc. 1.50 M In Depth, Complete All As Specified And Directed. , Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 250 Mm In Soft Loose Soil , Supply And Fixing Of Galvanised Iron Pipe 40 Mm Bore Dia Light Grade For Protection Of Ug Cable , Supply, Installation, Commissioning And Testing Including Providing All Necessary Electrical Connection,Lt Feeder Panel Board Of Size 1.0 M X 0.6 M X 0.5 M , Supply, Installation, Commissioning And Testing Including Providing All Necessary Electrical Connections Lt Feeder Panel Board Of Size 0.6 M X 0.6 M X 0.5 M , Supply And Fixing Earhing Complete With Gi Earth Plate Electrode Of Size 600X600X6Mm Thick.Complete All As Specified And Directed In Boq Spec File , Supply And Fixing Earhing Complete With Gi Earth Plate Electrode Of Size 600X600X6Mm Thick. Complete All As Specified And Directed In Boq Spec File , Supply And Fixing Of Sub-Class B Brick, Well Burnt, Laid Breadth-Wise Along The Axis Of Cable Laid In Trenches Over Sand Cushion Laid For Ug Cable Protection, Complete All As Specified And Directed. , Supply And Fixing Horizontal Boring Under A Depth Of 0.65 M From The Gl For Passing Pipe Upto 40 Mm Bore Dia , Supply Of Digging And Laying Of Removing Excavated Materials Soils Not Exc. 50 M And Depositing Where Directed At A Level Not Exc.1.50 M , Taking Down Out Unserviceable Or Serviceable Lt Ug Cables Of Nominal Cross-Sectional Area 300 Sqmm Including Bricks, Gi Pipes Etc. , Taking Down Out Unserviceable Or Serviceable Lt Ug Cables Of Nominal Cross-Sectional Area 50 Sqmm 3.5 Core Including Bricks, Gi Pipes Etc. , Supply Of Digging And Laying Of Sand Cushioning Dry In Trenches For Protection Of Ug Cables Below, Above And Around The Ug Cable Laid In Trenches Of 230 Mm Spread Thickness , Cutting Road By Hard Standing And Making Good Disturbed Surfaces By Using Pcc Type-C2,1-3-6 By Using 40 Mm Graded Stone Aggregate , Boring Of Holes Under Road,Pavement,Hard Standing By Trenchless Technology Using Ultra Sounding Technique Including Hdpe Pipe 150 Mm Dia Suitable For 0.4 Mpa Working Pressure , Cutting Chases, Chipping In Making Good To Facings, Where Required And Pointing In Cement Mortar 1- 3 To Ends Or Edges Of Landings, Steps, Sills, Sunshades, Shelves, Lintels Etc. , Submain Wiring Comprising Single Core 2 Runs Of 6 Sqmm Nominal Coss Sectional Area Frlh Multistranded Copper Conductor Cable, Pvc Insulated Total Quantity : 24953
Contract Date: Ref. Documents Contract Value : 60.79 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
West Bengal View Result →
Contract Date: Jul 03, 2026 Contract Value : 26.16 Lakh
Government Departments No of Bidders 9
Madhya Pradesh View Result →
3.
Rural Development #11481883 AOC
Tender For Annual Plan-Kuzhimanna Grama Panchayat Installation Of Mini Mast Lights-So315/26-General Electrical Work - wiring 2 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters 3 90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 4 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 5 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). 6 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels 7 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm 8 OD257774/2025-2026:SupplyandfixingoffollowingsizesofCorrugated PVC flexible conduit alongwithaccessoriesin surface/recess of proposed pole andmakinggoodthesameincaseofrecessed conduit as required 25 mm Corrugated PVC flexible conduit 9 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm 10 OD257790/2025-2026:Supply,installation,testing and commissioning ofDigital time swtch 40A, 2pole , AC1 rated power contactor with 1NO+1NC auxiliary contacts with AC coil and 24 Hours timer for operating automatic ON-OFF function suitable for single phase supply 11 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 12 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 13 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 14 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 15 OD257771/2025-2026:Supply and Fixing of 1P+N,40KA,1 module surge protector on existing MCB DB/enclosure/Meter Board etc and giving connection as required. (Schneider A9L40500 or equivalent) 16 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 17 OD257773/2025-2026:5 mm X 3 mm G.I. strip earth lead Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate 18 OD257775/2025-2026:Supply and installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-5345-NF ] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required 19 OD257780/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc 20 OD257777/2025-2026:Supplying and fixing32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board 21 OD257781/2025-2026:Supplying and fixing32A, HRC Fuse with HRC Fuse link with connections, in existing meter board 22 OD257778/2025-2026:Supplying and fixing of following sizes oflight class PVC conduit along with accessories in surface/ recess including cutting the wall/ground and making good the same in case of recessed conduit as required as service pipe 23 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board 24 OD257875/2025-2026:Supply, Providing and fixing Granite of any colour and shade for Name board, of required size laid over base of cement mortar 1:4 (1 Cement : 4 Coarse sand), including all charges etc. complete all, levels, including lettering and fixingetc as required at site. 25 OD257779/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required
Contract Date: Jul 01, 2026 Contract Value : 1.14 Lakh
Local Bodies No of Bidders 2
4.
Defence #11478095 Technical Bid
Tender For Provision Of Certain Revenue And Minor Work At Age B/R Ii Under Ge(N) Patiala=- 1 Dismantling, Floor, Hearth Or Wall Tiling Including Cm (Bedding (But Not Backing), Removing Serviceable Tiles To Store & Rubbish Off The Premises Complete All As Specified And Directed 2 M&L For Single Charge, Vitrified, Stain & Scratch Resistant, Premium Quality Coloured Tiles Area Of Each Tiles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm, In Floors Etc Mm And 8-10 Mm Thick, In Any Pattern Of Light & Dark Tiles As Approved, Laid Over 15 Mm Thick Screed In Cm (1:6) Epoxy Cartridge Tile Grout Using Filling The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour,Complete All As Specified And Directed. 3 All As Per Item No 2 Above But As In Skirting Over 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. 4 M&L For Ceramic Glossy Finish, Joint Free Premium Quality Coloured Tiles 600 X 300 Mm And 8-9 Mm Thick, In Any Pattern Of Light & Dark/Highlighters Tiles Etc As Approved, On Vertical Surfaces Such As In Skirting/Dado Etc, Set And Including 10 Mm Thick Rendering In Cement Mortar (1:4) And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 5 M & L For 15 Mm Thick Artificial Granite (Of Any Type) Work Steps, Jambs, Pillars, Window- Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. Including Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishes Complete All As Specified. 6 Providing And Laying Premium (1St) Quality Straight Edge, Ceramic Tiles Exterior Grade Scratch Resistance Of Size 300X300X7 To 8 Mm Thick In Floors Etc. In Any Shade And Design/Pattern Of Light & Dark Tiles Etc Set And Including 15 Mm Thick Rendering In Cement Mortar (1:6) And Pointed In White Cement With Pigment To Match Complete All As Specified. 7 Taking Up Or Down Existing Steel Tubing And Connections, 15Mm Bore Complete All As Specified. 8 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 15Mm Bore Incl Fittings Complete All As Specified And Directed. 9 Taking Up Or Down Existing Steel Tubing And Connections, 20Mm Bore Complete All As Specified. 10 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 20Mm Bore Incl Fittings Complete All As Specified And Directed. 11 S&F In Repair Angle Stop Cock With Wall Flange 15Mm Cast Copper Alloy, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No-Fon-40053Pm Or Equivalent In /Hindware/Kohlar. 12 S&F In Repair 15 Mm Bore Bib Cock With Wall Flange, Cast Copper Alloy, Chromium Plated, Fancy Type With Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No Opp-15037Pm Or Equivalent In/Hindware/Kohlar. 13 S&Fin Repair Brass Chromium Plated Basin Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar Cat Part No Orp-10011Bpm Or Equivalent In /Hindware/Kohlar 14 S&F In Repair 15Mm Cp Connection 600Mm Long Including Washer And Brass Nuts All As Specified. 15 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 16 S&F In Repair Counter Top Wash Basin Of Size 600 X465Mm With Wash Basin Cabinet Size 600X455X600Mm Including Bottle Trap , Brass Waste Fitting Complete All As Specified. Make:-Cera/Hindware/Jaguar 17 S&F In Repair Toilet Roll Holder Stainless Steel Flap All As Specified. Make- Jaquar Cat Part No Can-1153S Or Equivalent In /Hindware/Kohlar 18 S&F In Repair Towelrack 600Mm Long With Lower Hanger (Stainless Steel) All As Specified.(Make: Jaquar Cat Part No Acn -1181S Or Equivalent In /Hindware/Kohlar 19 S&F In Repair Soap Dispenser With Glass Bottle (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1135N As Equivalent /Hindware/Kohlar 20 S&F In Repair Soap Dish Holder With Glass (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Akp -35731P Or Equivalent In /Hindware/Kohlar 21 S&Fin Repair Towel Ring Square With Round Flange (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1121N Or Equivalent In /Hindware/Kohlar 22 S&F In Repair Healthfaucet With 1Mtr Long Easy Flex Tube In Chrome Finish And Wall Hook Of 15 Mm Bore With Cp Pipe Complete Set Of Make -Jaquar Cat Part No Ald - 565 Or Equivalent In Parryware/Prayag 23 S&F In Repair Looking Mirror 5Mm Thick Size 3.5X3.5 Feet Incl Stud And Fastners Complete All As Specified And Directed. 24 S&F In Double Arm Wall Mounted Reversible Plain/Magnifying (X3) Pivotal Mirror All As Specified. Jaquar Cat Part No Acn -1193N Or Equivalent In /Hindware/Kohlar 25 S&F In Repair Glass Shelf Corner With Bracket Of Size 225Mm X 225Mm Thickness Of Glass 6Mm) With Cp Brass Railing And Brass Screws.Make- Jaquar Cat Part No Acn -1173 Or Equivalent In /Hindware/Kohlar 26 S&F Grating Doom 125Mm Of Ptmt. 27 S & F In Repair Vitreous China Urinal Half Stall Type White (Excluding Flushing Cistern ) Including Waste Fitting, Waste Pipe Complete All As Specified.Make-Jaquar/Hindware/Kohlar 28 S&F Ms Work In Tubular/Pipe/Angle Sections For Frame Work For Roof, Vertical Poles, Rafters And Purlins Including Washer Etc Complete All As Directed. 29 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. ( Design Of Sheet As Mangalore Tiles Pattern In Red Colour ). 30 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. 31 M & L Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Incl Preparation Of New Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. 32 M&L 25Mm Thick Factory Made Coloured Interlocking Designer Polished Floor Tiles (Ultra Pattern) Of Grade M-35 Of Shape And Size As Directed,And 100Mm X 100Mm Size Tiles Piece On Every Joint Of Tiles Flooring Laid Over & Including 20Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed . Note: Sample Shall Be Got Approved From Ge Before Commencement Of Work 33 S&F In Repair Stainless Steel Drapery Rod Of 20 Mm Inner Dia (In Lengths As Directed) Of & Including Decorative Finial At Both Ends And Pair Of S S Steel Brackets Fixed At Both Ends With Pvc Rawl Plug & Steel Screws On Walls/Beam, (Victorian Design)All As Specified & As Directed. Make -Sample Can Be Seen In The Office Of Engg-In-Charge For Checking And Quoting The Same 34 Demolition Of Cement Concrete Un -Reinforced In Ground Floors And Pavings N.Exc 15Cm Thickness Complete All As Specified. 35 M& L For 25Mm Thick Pcc 1:2:4 Type Bo Using 12.5 Mm Graded Stone Aggregate As In Floor Complete As Specified And Directed. 36 S & F 75 Mm Dia Pvc ( Swr ) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified. 37 S & F Floor Door Stopper Of Aluminium Alloy And Tongue, Anodised With Hard Drawn Steel Overall Length Of Cover Plate 140Mm.As In Repairs Complete All As Specified. 38 Dismantling Of Wall And Ceiling Board(Fiblre, Pulp, Insulation Etc) Any Thickness Including Cover Fillets Complete All As Specified And As Directed. 39 S & F Powder Coated Aluminum Alloy Interlocking Snap Grid Frame Work For False Ceiling Size 600Mm X 600Mm Consists Of Main Tee Runners Of Size 38Mm X 38Mm X 1.5Mm And Cross Tee Of Size 38Mm X 38Mm X 1.5Mm, Spaced Between The Main Tee At 600Mm Centre To Centre To Form A Grid Of 600Mm X 600Mm Complete All As Specified And As Directed And As Per Manufacturer. Instruction. 40 M & L For 4Mm Thick Non Asbestos Fibre Cement Building Boards Of Make E Board Classic Designer Board (Cascade Or Occenic) Of M/S Everest Industries Ltd Or Equivalent As Approved, By Ge Fixed Or Laid/ Inserted To Timber/Gi/Aluminium Framework With Complete All As Specified And As Directed. 41 Taking Down Cement Mortar Plastering On Brick Or Stone Walls, Etc. Including Raking Out Joints,Hacking For Key,Scrubbing Down With Water, Etc Complete All As Specified And As Directed. 42 M&L For Rendering 15Mm (In Two Layers 10Mm+5Mm) Thick Plaster In Cm (1:4) On Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 43 M&L For Rendering 5Mm Thick Plaster In Cm (1:3) On Faces Of Brick Work Or Concrete On Surfaces Of Ceiling, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 44 Complete Removal Of Existing Treatment Including Washing Rubbing Down And Stopping Of Painted Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 45 M&L For New Plaster Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 46 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 47 M & L For Cement Concrete As Pcc 1:5:10 Type E-2 Using (40Mm Graded Stone Aggregate) As Foundations,Filling And Mass Concrete Complete All As Specified. 48 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 49 Demolition Of Brick Work Or Stone/Boulder Masonary, Laid In Cement Mortar Or Cement Lime Mortar Complete All As Specified. 50 M&L Brick Work, Straight Or Curved On Plan N.Exc 6M Mean Radius In Cm 1:6 Using Old Size Brick Complete All As Specified. 51 Taking Down Chowkat Or Frame With Shutters (With Out Taking Off Shutter From The Frame ) Not Exceeding 1.5 Sqm Each As Directed By Engineer-In-Charge. 52 S&F For Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door Frames/Chowkhat Comprising Of 100 Mm X 65 Mm Size, Applying Pvc Solvent Cement And Screwed With Full Body Threaded, Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/Cum And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With Mild Steel Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete All As Specified And As Directed By Engr-In-Charge. 53 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Solid Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 54 S&F Stainless Steel (304 Grade) Finished Butt Hinges 125Mm Complete All As Specified And Directed 55 S & F Extruded Brass Handles, Fabricated Type Polished 150 Mm Complete All As Specified. 56 S & F Brass , Barrel Tower Bolts, With Cast Or Sheet Barrel And Rolled Or Cast Bolts And Fixed 200 Mm Complete All As Specified. 57 M&L For 250Mm Long Brass, Sliding Door Bolt Withsand Or Die-Cast Brass Hasp, Staple (Bolt Type) And Fixing Bolt With Rolled Or Drawn Brass Bolts And Fixed Complete All As Specified And As Directed. 58 Dismantling Pvc Pipes With Fittings Upto 75Mm To 110Mm Dia Complete All As Specified And Directed By Engr-In Charge.. 59 S&F For Pvc (Swr) Pipe 110 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 60 S&F For Pvc (Swr) Pipe 75 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 61 S&F For Pvc (Swr) Bends With Access Door 110 Mm Dia Complete All As Specified And As Directed. 62 All As Per Item No 61 Above But 75 Mm Dia. 63 S&F Pvc (Swr) Plain Bend 110 Mm Dia Complete All As Specified And As Directed. 64 S&F Pvc (Swr) Plain Bend 75 Mm Dia Complete All As Specified And As Directed. 65 S&F Pvc (Swr) Branch Piece Single Or Double T Equal Or Unequal With Access Door 110 Mm Dia Complete All As Specified And As Directed. 66 All As Per Item No 65 But 75 Mm Dia. 67 S&F Pvc (Swr) Vent Cowl 110 Mm Dia Complete All As Specified And As Directed. 68 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50 M And Making Good Surface 69 M&L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc. And Making Good, Cutting Not Exc 10 Cm Girth All As Specified. 70 Taking Down Carefully Existing Points Wiring On Surface Conduit/Concealed Conduit Including Conduit From Surface And Expect Conduit In Concealed Wiring For Light/Fan/Socket/Power/Bell From Wall & Roof Along With Fitting And Fixtures Such As Switches, Sockets, Ceiling Roses, Batten Holders, Unserviceable Light Fittings, Pieces Of Wires, Gutties, Conduit, Wooden Boards Etc Removing Materials To Store For Keeping In Safe Custody Of Contractor For Which The Credit Has Been Considered Under Schedule Of Credit And Making Good The Disturbed Portion Of All Floor, Ceiling Etc All As Specified And Directed. 71 M & L For Point Wiring With 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor For One Light/Fan/Bell Point In And Including New Pvc Rigid Non Metallic Concealed Conduit 19/20 Mm Dia, Medium Duty, Isi Marked To Be Terminated In Pressed Steel Terminal Boxes With Pvc Modular Top Cover Plates Of Suitable Size For Mounting Of Modular Type Switches/Sockets/Regulators Including 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Earth Continuity Conductor Controlled By One Switch And/Or One Regulator Complete Including Cutting Chases And Making Good The Surfaces In Cm 1:3 And Finishing The Surface As Per Existing Treatment All As Specified And Directed By Engr-In-Charge.Notes: (I) Cost Of Pressed Steel Terminal Boxes And Modular Top Cover Plate Shall Be Included In Point Wiring. (Ii) Wiring Shall Be Done As Per Colour Code In Is For Phase, Neutral And Earth.(Iii) -Cost Of Eye/Bottle Thimbles Used For Connection In Switches/Sockets & Mcbs In Dbs Shall Deemed To Be Included In The Unit Rate Quoted For This Item. 72 All As Per Sl Item No 71.00 Above Herein Before But One Socket Out Let 5 Pins 5 Amp On The Same Board With Other Switches Complete All As Specified And Directed. 73 All As Per Sl Item No 71.00 Above Herein Before But For One Socket Out Let 5 Pins 5 Amp On Independent Board Complete All As Specified And Directed. 74 All As Per Item No71.00 Herein Before But 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor Incl 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Copper Earth Wire For Switch Socket Combination 3 Pin 15 Amps On Independent Board. 75 S & F In Replacement Of Modular Switch 1 Way, 6 Amps, 1 Module, 230 Volts Complete All As Specified. 76 S & F In Replacement Of Modular Switch 1 Way, 16 Amps, 1 Module, 230 Volts Complete All As Specified. 77 S & F In Replacement Of Modular Socket 5 Pin 6 Amps, 2 Module 230 Volts Complete All As Specified. 78 S & F In Replacement Of Modular Socket 5 Pin 6 &16 Amps, Combination Type 2 Module Complete All As Specified. 79 S & F In Replacement Of Modular Fan Regulator Step Type, 120 Watts, 2 Module Complete Fixed As In Repair All As Specified. 80 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 81 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Green Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 82 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Red Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 83 Supply And Fix Surface/Recess Mounted Led Luminaire 36 Watt Cool White 4000-5000K Suitable For Gridd Celling Cutout Dimensions: 2X2 Ft. Incl Connecting With Twin Core Copper Wire From Ceiling Rose To Fitting, Fixture Size: (Lxwxh) In (595X595X65) Mm Incl Lamp And Driver All As Specified & Directed. 84 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 18/20W 6500K Of Capacity ,20 Watt,4 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 85 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 86 Supply And Fix Mirror Light With Linear & Compact 12 W Mirror Light With Decorative Grey End Caps, Polycarbonate Body And Ribbed Opal Diffuser Of Capacity 9 Watt Complete All As Specified And Directed By Engr-In-Charge. 87 M & L For Sub Main Wiring With Two Single Core 4.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 4 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2 Runs Of 4.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 4.00 Sqm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note2 : Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces, Cutting Not Exc. 10 Cm Girth . (Iii) Taking Out/Down Existing Unserviceable Sub Main Wiring. 88 Taking Down And Refixing Of Ceiling Fan After Supply And Replacement Of Rubber Reel, Round Cover Plate Of Size 6 Inch Of Ceiling Fan Complete With Ms Split Clamp Two Nos, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 89 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 250 Mm Sweep 900 Rpm Engineering Thermoplastic Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Louver Complete All As Specified And Directed By Engineer-In-Charge. 90 Material And Labour For Making Hole Of Suitable Size For Exhaust Fan 250 Mm/ 300Mm Sweep In Wall For Grouting And Making Good The Surface Complete All As Specified And Directed By Engr-In-Charge. 91 Supply And Fixing Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With Mcb Spn 32 Amps, Complete All As Specified And As Directed By Engineer-In-Charge. 92 S&F Poly Coated Gi Frame Work As In Grid For False Ceiling Comprising Of Protected Gi Perimeter Channel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleves And Screws At 450Mm Centre To Centre/Intermediate Chaqnnel 0.9Mm Thick Having To Equal Flanges Of 15Mm Each And Web Of 45 Mm Suspended From Soffit And Approx 900Mm Centre To Centre With Gi Cleat And Steel Expansion Fasterners With And Including Ceiling Section (Not Exc 1.2 Metre Length) Of 0.55Mm Thickness Having Kurled Web Of 50Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel With Connecting Clips Acorss The Intermediate Channel At 457Mm Centre To Centre And Hangers 6Mm Dia Gi (Upto 1200 Mm Length Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X3Mm Size 60Mm Long Complete With And Including 7Mm Thick Pvc Laminated Gypsum Tiles Of Size 595X595Mm Complete All As Specified & Directed 93 M&L For Complete Removal Of Existing Surfaces Of Walls Including Cornices, Pillasters Etc, And Applying Two Coats Of Obd Over And Incl A Coat Of Interior Wall Primer Over Wall Care Putty Complete All As Specified And Directed. 94 M&L For Complete Removal Of Existing Treatment On Walls And Applying 02 Coats Of Exterior Weather Emulsion Paint To External Walls/Rcc Surfaces/Soffits Of Chajjas/Roof Projections/Cantilevers/Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer And Over Wall Care Putty Complete All As Specified. 95 S&F Stainless Steel Tubing Of 25 Mm Dia Chromium Plated Min. 1.0 Mm Wall Thickness As In Curtain Rod Complete Incl S&F 02 Nos Stainless Steel Brackets/Finials Fency Type, Stops Fixed With Ss Screws Etc All As Specified & Directed.Note : For The Purpose Of Mesurement And Payment Running Length Of Curtain Rod Only Shall Be Considered. 96 Taking Down Chowkhats Or Frames Of Any Description Exc 1.5 Sqm And N. Exc. 4 Sqm Each (Without Taking Off Shutters From The Frame) Including Cutting Hole To Size For Receive Fresh Pcc Of Hold Fast And Making Good The Disturbed Surface Same Complete All As Specified And Directed. 97 S&F Factory Made Pressed Steel Frames Made Of Ms Sheet Of 1.20 Mm Thickness For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified,Size 125X60Mm 98 M&L Pcc 1:3:6 Type C-0 In 12.5 Mm Graded Stone Aggregates Hold Fast Fillinng Inside Frame & Hold Fasts Etc Complete All As Specified 99 S&F Factory Made Flush Shutters 35Mm Thick Ply Construction, Bwp Confirming To Is 2202, Solid Core Construction, With Block Board Core And Plywood Face Panels Commercial Type On Both Sides With 6Mm Thick Lipping Frame To Match Including Supply And Fixing Following Items :(A) Mild Steel Butt Hinges 125Mm - 3 Nos. Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos. Per Leaf(D) Stainless Steel (804 Grade) Finished Sliding Bolt 250 Mm - 1 No. Per Leaf(E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 100 S&F 35Mm Thick Glazed And Skelton Shutters Of 2Nd Class Hard Wood (Factory Made) Open Rebated And Divided To Receive Glass, Gauze Etc (Without Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc Size Of Members Of Shutter As Specified In Ssr-91 Pt-1 Section 8 Clause 8.20(A), Kiln Seasoned And Chemically Pressure Treated All As Specified Including Stainless Steel 304 Grade Wire Cloth (0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm) All As Specified And Including Supply And Fixing Following Items :(A) Stainless Steel (304 Grade) Finished Butt Hinges 125Mm - 3 Nos Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos Per Leaf(D) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16X250Mm - 1 No Per Leaf (E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 101 M&L For Two Coat Of Synthetic Enamel Paint (Finishing Coat) Over One Coat Of Pink Primer To New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Incl Prepration Of Surfaces Complete All As Specified And Directed. 102 S&F 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed. 103 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 104 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X35 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 105 S & F In Replacement Of Surface Mounted Led Bulk Head Luminaire Of Capacity 10 Watt With Abs Body & Polycarbonate Diffuser, Ip54 Inc Connection With ,With Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 106 Supply And Fix Lamp Holder Including Led Bulb 9 W Including Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 107 M & L For Sub Main Wiring With Two Single Core 6.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 6.0 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2(Two) Runs Of 6.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 6.00 Sqmm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note 2 :(I) Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces And Cutting Not Exc. 10 Cm Girth . (Iii) Including Taking Out/Down Existing Unserviceable Sub Main Wiring. 108 S & F In Replacement Of Sheet Metal Enclosure Db Tpn 4 Ways Double Door 415 Volts With 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables Complete With Ip-43 Protection Complete All As Specified And Directed By Engr-In-Charge 109 S & F In Replacement Of Mcb, Triple Pole & Neutral (Tpn) 10 Ka 240 Volts 40 To 63 Amp Capacity Fixing In Db’S Complete All As Specified And Directed. (Note: Mcb Should Be B Or C Curve As Directed By Engineer In Charge) 110 Supply And Fix In Replacement Of Sheet Metal Enclosure 8 Ways Double Door For Dbs When Mcbs Are To Be Used 240,Volts Including 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link All Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables With Ip43 Protection Complete All As Specified & Directed By Engr-In-Charge. 111 S & F In Replacement Of Mcb, Single Pole 240 Volts 6 To 32 Amp Capacity For Fixing In Db’S Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 112 Supply And Fix In Replacement Of Mcb , Spn, 240 Volts ,40-63 Amp For Fixing In Dbs Of Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 113 M & L In Replacement Of Unsv Earthing Complete With Galvanized Iron Earth Plate Electrode Of Size 600X600X6.0Mm , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Below Normal Ground Level) With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Bolts , Nuts , Check Nuts And Galvanized Iron Or Steel Including Earth Work In Any Type Of Soil, Charcoal Salt 15 Cm Around The Earth Plate 20 Mm Dia Watering Pipe Medium Grade 1.70 Mtr Long With A Plug At Top, Gi Protection Pipe Light Grade 15 Mm Dia From Earth Pit To Main Board Including Pcc Pit In Cement Concrete 1:2:4 Along With Ci Frame And Cover 10Mm Thick Duly Hinged To Ci Frame As Shown In The Electrical Plate No3 Of Ssr 2009 Part 1 Specification At Page 497. 114 Xlpe Insulated ,Screened, Pvc Bedded, Galvanized Steel Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sq Mm 4 Core Supplied & Laid In Replacement Complete All As Specified& Directed By Engineer-In-Charge. 115 Excavation In Trenches Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth For Laying Of Cables Including Getting Out In Any Kind Of Soil Complete All As Specified And Directed. 116 Returning Filling In Including Spreading, Levelling, And Well Ramming, In Layers Not Exceeding 25 Cm Each Layer Of Any Kind Of Soil. 117 Removing Surplus Excavated Material From Site Not Exceeding 50 Mtrs From Starting Point And Depositing Where Directed At Level Not Exceeding 1.5 Mtr Above The Starting Point. 118 Material And Labour For Sand Cushioning For Cables 8 Cm Below The Cable And 15 Cm Above With Dry River Sand In Trenches For Cushioning Of Underground Cable Line Including Spreading, Leveling, Well Ramming Completed All As Specified And Directed. 119 Cutting Of Hardstanding Floor/Wall For Laying Of Cable Including Matching With Suface By Using Cement Concrete All As Specified And Directed. 120 Supplying & Laying Factory Made Unreinforced Precast Concrete Cable Covers Class Lv Type 1, Flat, Size 250X150X40Mm Laid In Trenches As Protection To Cables Complete All As Directed By Engr-In-Charge 121 Material And Labour For Replacement Of Gi Tubing Light Grade 40 Mm Bore For Passing Through Cables Under The Floor ,Along The Wall Or Along The Pole Complete All As Specified And Directed. 122 Dismantling Of Stone Slab And Tiles Laid Bedded And Pointed In Any Mortar Description Or Thickness In Floors, Apron Etc Complete All As Specified. 123 M & L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick In Cm 1:6 For Laying Floor Finishes Complete All As Specified. 124 M&L For Virified Ceramic Light Shade Tiles 8 - 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc,Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Epoxy Cartridge Tile Grout Using Fill The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour. 125 All As Per Item No 124 But As A Skirting Incl. 10Mm Thick Rendering As In Back Coat Complete All As Specified. 126 M&L For 7 To 8 Mm Ant-Skid Ceramic Joint Free Premium Quality Coloured Tiles Area Of Each Tile Esc 0.06 Spm But Next 0.11Sqm, As In Floors Etc. In Any Pattern Ghe & Dark Tiles As Approved, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, In Floors Etc. Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 127 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Laid Over Cement Screed Base 15Mm Thick In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 128 Rounding To Edges Of Stone Slabs One Edge, Such As In Steps, Cooking Platform, And Other Similar Situations All As Specified. 129 Dismantling Water Tanks And Removing To Store Of Capacity Exc 500 & Not Exc 1000 Ltrs Complete All As Specified. 130 Supply And And Fixing, Hoisting Pvc Tank Of 1000 Ltr Capacity Including Supplied And Fixed 20Mm Dia Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed.(Minimum Weight 15Mm-142 Gms/20Mm-210Gms/25Mm-455 Gms/40Mm-690 Gms Float Valve Assembly Complete All As Specified And Directed. 131 S&F In Repair Wall Mixture Mixing Valves Incl. Three Joints To Steel Pipes Or Unions 15 Mm Bore Fancy Type Best Quality As Per Sample Approved By Ge Make-Jaquar Cat Part No Qqp-7217Pm Or Equivalent In Hindware/Kohlar. 132 S&F Pvc Cabinet 600X450Mm Overall Size With Looking Mirror Of Selected Qality Glass Mountedover Pvc Framing As Per Sample Complete Fixed In Repair Complete All As Specified. 133 S&F Stainless Steel Plate Rack Of Size Not Less Than 90Cmx75Cm(Wt N. Less Than 4 Kg) Fixed With Stainless Steel Screw Including Taking Out Old Unserviceable Wooden Plate Rack As Approved By Ge Complete All As Specified. 134 S&F In Repairs Chromium Plated Shower Roses With Swivel Joints 125 Mm Dia Size Incl Fixing To Gi Pipe/Union Fixed Make-Jaquar /Hindware/Kohlar. 135 M & L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6 Finished Even And Smooth ( Without Using Extra Cement ) With Sagol Finish On Plastered Surface Complete All As Specified And As Directed. 136 M&L For Preparation Of New Decorated Plastered Or Unplastered Surfaces Of Walls And Applying Two Coats Of Exterior Emulsion Over One Coat Of Primer And Over 2Mm Thick Putty For Levelling And Smoothening, Complete All As Specified And Directed. 137 M&L Preparation Of New Plastered Surface Of Walls And Applying Two Coats Of Oil Bound Distemper Over 1.5Mm Thick Wall Care Putty Complete All As Specified And Directed. 138 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 139 S&F Sinks With Drainage Board Made Of Stainless Steel Lmm Thickkitchen Or Laboratory With Plugs,Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. 140 S&F In Repair Brass Chromium Plated Sink Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar /Hindware/Kohlar 141 S&F Powder Coated Anodised Aluminium Frame For Doors, Windows Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. 142 S&F Frosted Glass 4.00Mm Thick Ordinary Quality And Glazing With Oil Putty In Square N.Exc 0.50Sqm In Each Panes Complete All As Specified And Directed. 143 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Sketon/Glased Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 144 S&F Factory Made Wpc Extruded Board Cnc Machine Cut Jali Fixed To Skelton Door As Per Approved Design Complete All As Specified And Directed 145 S&F Kitchen Cabinets Including All Fittings And Fixtures Incl The Follwing. (A) 19Mm Thick Plywood Of Commercial Block Board,Make: Kitply/Century Ply/ Green Ply(B) 1Mm Thick Commerical Lamination On Both Side Fixed To Black Board(Colour And Design As Approved)(C) Ss Pullout Basket Ss Finish Of Plain 15 X 20 X 6 (D) D Type Handle 100Mm Ss Finish(E) Pullout Basket Ss Finish Cutlery Wire Of Size 15X20X4 (F) 2Nd Class Hard As In Frame Work(G)Ss Channels For Pullout Basket As Required. (Note:- The Measurement Shall Be Taken From Front Elevation And Not Girthwise. 146 S&F Factory Made Upvc Brown Colour Door Shutter Made Of Extruded Profile With Wall Thickness Of 2.3Mm(+-0.2Mm) Door Profile With Hollow Section With Multy Chamber. Frame (60X62Mm),Sash(42Mmx67Mm).Sliding Interlock(One Verticle Length In Each Shutter)(45.5Mmx28Mm).Glazing Bead(24.5Mmx16Mm)Will Be Mittred Cut And Fusion Welded At All Corner.Including Drilling Holes For Fixing Hardware And Drainge Of Water Etc Am,.Making Arrangement For Fixing Of Hardware.Epdm Gasket,1.2+0.2 Mm Thick Galvanised Steel Frame(30Mmx21.5Mm).Sash (30Mmx18Mm)Profile To Be Inserted In Required Profile.Frame Will Be Finshed To The Wall With 8Mmx100Mm Long Fasteners.Hardware Touch Lockof Zinc Alloyed(Brown Powder Coated)Steel Roller System Including 5Mm Thick Glazing With Selected Quality Glass ,Aluminium Track And Bottom Rail For Two Track Sliding Fram,Wool Pine For Sliding Sash And Interlock. Note.The Unit Rate Coated By Contractor Includes Cost Of Glass And All Other Conncted Accessories,Net Opening Will Be Measured For Purpose.Make:H2O Window,Fenesta,Anuplast As Approved By Ge. 147 M&L For Rcc 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate In Any Situation Except Foundation Complete All As Specified And Directed. 148 S&F 10Mm Dia And Above Tmt Bars Cut To Length, Bend To Shape As Required Including Cranking, Hooking Ends & Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Complete All As Specified And Directd. 149 All As Item No 77 Here In Before But 5Mm Dia And Over Upto & Including 10Mm Dia In Stirrups, Spaces & Binder Complete All As Specified And Directd. 150 S & F Powder Coated Aluminium Window/Ventilator Shutters, Side Hung Type With Sash Bars, Including Necessay Joinery Cleats, Glazing Clips, Rubber Packing, Chowkats Aluminium Snap Beading, Screws, Suitable Handle Etc With And Including Sheet Glass Or Ordinary Glazing Quality Of 4Mm Thick And Incl Gi Wire Mesh 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 Mm , Size Of Side Rails , Top Rails , Bottom Rail 85X44.5Mm And Size Of Chowkat Frame 101.6X44.45Mm And Thickness Of Aluminium Member Shall Be 1.40Mm Thick Complete All As Specified. 151 S&F For Prelaminated Particle Board 18/19 Mm Interior Grade Prelaminated On One Side With Decorative Choice Lamination And Other Side Balancing White Lamination Fixed With Screw Timber Frame Work Including Dismantling Board All As Specified. 152 S&F In Repair Continuous (Paino) Hinges, Mild Steel, Bright Finish Or Electrogalvanised Width Of Flap (When Open) In 40Mm All As Specified. 153 S&F In Repair 40Mm Dia, Cupboard Knobs Fixed With Nut, Screw And Washer Of Mild Steel Bright Finished All As Specified. 154 S&F Ball Catches With 8Mm Dia Steel Ball And Brass Body And Striking Plate Including Letting In And Fixing Complete All As Specified. 155 Supply & Fix In Replacement Of Modular Bell Push Switch 1 Way, 6 Amps, 1 Module Complete All As Specified. 156 Supply & Fix In Replacement Of Call Bell Ding Dong Ac 230 Volt Single Pole Complete All As Specified. 157 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 300 Mm Sweep 900 Rpm Metal Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Hole Making Louver Complete All As Specified And Directed By Engineer-In-Charge. 158 S & F Modern Energy Efficient Bedroom Muziris Wall Decorative Light Of Capacity 20 Watt Single Headed 240 Volt, Ip20 Rating, Controller Type (Push Button), Product Weight 1.04 Kg, Body Material (Metal), Power Source (Corded Electric),Lamp Base E27, Colour(Bronze) Incl Electrically Connection , Including Removing Of Unserviceable Decorative Light Fittings Of Any Description Complete All As Specified And Directed By Engr-In-Charge. Make: Philips Model No 31425 Or As Equivalent. 159 Excavating In Trenches N Exc 1.50M In Width And N Exc 1.50M In Depth For Foundation, Manholes Etc As Well As N Exc 10 Sqm On Plan Area And Getting Out In Soft/Loose Soil All As Specified And Directed. 160 M&L For Pcc 1:5:10 Type E-2, Using 40Mm Graded Crushed Stone Aggregate In Foundation, Filling And Mass Concrete All As Specified And Directed. 161 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 162 S&F Mild Steel Deformed Bars, 6Mm To 8Mm Dia Cut To Length, Bent To Shape Required Including Cranking And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0-.90Mm Dia Complete. 163 M&L For Form Work To Soffits Of Suspended Slabs Such As Roof Slabs Etc For Rough Finished Concrete Surface Complete All As Specified And Directed. 164 M&L For Form Work To Sides For Slabs And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N Exc 20 Cm Wide For Fair Finished Concrete Surface Complete All As Specified And Directed. 165 Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams And Similar Work, Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete. 166 Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions, Square, Rectangular Or Polygonal For Rough Finished Flat Surfaces Of Concrete. 167 M&L For Rendering In Cement Mortar (1:6) 10 Mm Thick Finished Even Smooth Complete All As Specified On Brick Or Concrete Surface Of Fair Faces. 168 M&L 15Mm Thick Cement Plaster In Two Layer First Coat In Cm 1:6,10Cm Thick & Second Layer 5Mm Thick In Cm 1:4 Mixed With Wpc 3% By Weight Of Cement Including Finishing Fair & Even On Brick Or Concrete Surfaces Of Othern Than Fair Faces. 169 M&L For 5Mm Thick Cement Plastering To Rcc Surfaces In Cm :1:3) Finished Even And Smooth W/O Using Extra Cement On Ceiling Surfaces. 170 S&F Stainless Steel Butt Hinges Medium Weight Cold Rolled Isi Marked Of Size 100 Mm Complete All As Specified And Directed. 171 M&L For Ms Framed Guard Bars Conforming To Fe-410-0 Or Fe-310-0 Welded To Steel Windows/Ventilations Complete All As Specified And Directed. 172 S&F Vitrous China Squatting Pan Of Orissa Patterns Long Pan Size 580Mx440Mm White With P Or S Trap Front Of Back Inlet And Foot Rest Including Long Band Any Pattern (Excluding Flushing Cistern And Flush Pipe) Including Provision For Lime Concrete Bedding. 173 S&F Pvc Flushing Cistern Low Level 10 Ltr Cap With Inlet Ball Valve Float And Handle Syphonic Action Type Incl Brackets And Flush Pipe Of Polythene Of Low Or High Density Isi Marked. 174 S & F In Repairs Vitreous China Oval Shape Wash Basin, White, Flat Back, Size 580 X 450 Mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets With 32 Mm Dia Waste Fittings, Brass, Chromium Plated With Waste Pipe Complete All As Specified. 175 S&F Looking Mirror Of Selected Quality Mounted On 6 Mm Thick Ply And Fixed To Wall With Wooden Plugs Chromium Plated Brass Screws And Washers. 176 S&F For Ci Floor Trap With Incl Jointing With Waste Pipe In Cement Mortar Of Size 100Mm. 177 S&F Gully Trap Stone Ware Square Of Round Mounted Type P Of Size 150X150Mm. 178 S&F 20Mm Dia Stop Valve Of Copper Alloy Screwed Down High Pressure With Crutch Or Butter Fly Handle Screwed On Both Ends For Iron Pipe Or For Union Fixed. 179 S&F Pvc Connection 15Mm Dia 600Mm Long Of Heavy Grade Screwed One End To Inlet Of Whb/Pillar Tap/Cistern Etc Complete Incl Brass Union Coupling On Both Ends Connfirming To Is-3076 Complete With Connector For Connection Old Water. 180 S& F For Ci Pipe 75Mm Dia Laid In Floor In Any Length With Or Without Cars With Cement Joint (Waste & Vent Pipe). 181 All As Per Item No 38 Here In Before But 100Mm Dia. 182 S&F For Ci Bend Any Radius Disminshing Pieces Or Tyes Of 100Mm Bore With Ducks For Or Head Rest. 183 S&F For Ci Branch Pieces Single Equal Or Unequal Ordinary Or Inverted Or With Paralled Brnach 100 Mm Bore. 184 S&F Cast Iron Sand Cast Pipe 100 Mm Dia With Or Without Cars With Cement Joint Fixed To Walls. 185 S&F Cast Iron 100 Mm Cowl. 186 M&L For Pcc 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate)75Mm Thick On In Sub Base Of Fllor .. 187 M&L For 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directd. 188 M&L For Coloured Glazed Ceramic Tiles On Vertical Surface (300Mmx600Mx7M) Thick Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 189 M&L For Coloured Non Skid Ceramic(300X300Mm) Tiles 7 To 8Mm Thick As In Floor Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 190 S&F Steel Ventilation With Top Hung Shutter Including Hinges, Steel Peg Stay Complete. 191 S&F 4Mm Thick Sheet Glass Of Figured,Pin Headed And Glazing With Oil Putty In Square N Exc 0.50 Sqm In Each. 192 M&L For Preparation Of Newly Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Over 10 Cm Width Or Girth Complete All As Specified And Directd. 193 M&L For Preparation Of Newly Plastered Surfaces And Applying Two Coats Of Cement Base Paint Over A Coat Of Chalk Whiting Complete All As Specified And Directd. 194 M&L For Three Coats Of White Wash On Wall Of Newly Plastered Surface. 195 S&F For Preparation Of Newly Plastered Surfaces And Applying Three Coats Of White Wash On Ceiling. 196 M & L For Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. 197 S&F Factory Made Solid Pvc Moulded Door Shutter, With Particle Board Core, 28 To 30Mm Thick (Stiles), With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Pvc Sheet On The Front Face & 2Mm Plain Colour Pvc Sheet On Back Face & 5Mm Thick Plain Colour Pvc Sheet On Back Face, Supplying & Fixing In Frame At Site As Per Specification & Drawing All As Specified. 198 S&F Aluminium Tower Bolt 150Mm Long Stove Enamelled Black With Bright Bolt & Fixed. 199 S&F Aluminium Sliding Door Bolt With Hasp And Staples Type Bolt Type , 300Mm Long Stove Enamelled And Fixing Clips Of Sheet Cast Or Extruded Section Or Cast Aluminium Alloy And Fixed All As Specified. 200 S&F Aluminium Alloy Handle Of 100M Size Oval Type Stove Enamelled & Fixed All As Specified. 201 M&L For Rendering 10Mm Thick Cm (1:4) On Roof Slab Top, Mixed With Water Proofing Liquid Finished Even And Fair Without Using Extra Cement Complete All As Specified. Note: Water Proofing Liquid Shall Be Measured And Paid Separately. 202 M & L For Cleaning The Newly Plastered Surfaces Of Concrete ( Roof Etc) With Wire Brushes And Applying Water Proofing Treatment As Under :-I) Apply One Coat Of Oil Bound Bituminous Primer @ 0.25 Kg/Sq.M Ii) Providing And Laying 3 Mm Thick App Modified Water Proofing Membrane Weighing Not Less Than 3.5 Kg / Sqm Reinforced With Non Woven Polyester Mat Weighing Not Less Than 160 Gm/Sqm All As Specified Procured From Any One Of The Approved ManufacturerS Iii) Apply One Coat Of Solar Reflective Bituminous Aluminium Paint @ 0.15 Kg/Sqm Over Membrane Over Non Assesble Roof Surfaces Complete All As Per ManufacturerS Instructions And As Directed . 203 M/L Brick Work In Cm1:4, In Half Brick Thick Wall. 204 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 205 S/F Vitreous China Toilet Paper Holder Fixed To Walls With Chromium Plated Cp) Brass Screws 206 S/F Vitreous China Soap Dish Of Appx Size 160*160*90Mm Any Type Fixed To Plugs With Chromium Plated Brass Screws 207 S/F Sheet Glass Shelf Assembly Consistig Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Brackets Guard And Railing 60Cm Long 208 S & F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges Complete All As Specified. 209 M & L For Granite 20 Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Griding And Polishing Types All As Specified. 210 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 211 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 212 S&F Health Faucet Including Ms/Anodised Hanging Device Fixed Complete All As Specified And As Directed. 213 Surface Excavation Not Exceeding 30Cm Deep And Averaging 15Cm Deep And Getting Out In Loose / Soft Soil All As Specified And Directed. 214 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 215 M & L 100Mm Thick Pcc 1: 4: 8 Type D2 (Using 40Mm Graded Stone Aggregate) As In Sub Base Complete All As Specified And Directed. 216 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Rubber Moulded Any Shape And Size Confirming To Is 15658-2006 Of 60Mm Thickness, M-35 Grade With Grey And Pigment As In Floor/Pavement Complete All As Specified And As Directed. 217 M&L For Providing Precast Concrete Type C-1, 1:2:4(Using 20Mm Graded Stone Aggregate) As In Kerb Blocks With Plain Fiar Faces, Including Chamferes, Weathering, Throating Etc And Setting In Mortar 1:4 Complete With Joints To Match. 218 M&L For Cement Concrete Type 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 219 M & L For Sand Filling Under Floors Or In Foundation Including Watering And Consolidation 220 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X25 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 221 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 222 M&L For Boring Of Holes Under Road, Pavement, Hard Standing By Trench-Less Technology Using Ultrasound Technique And Necessary Machine Suitable To Pass Through 40 To 80 Mm Bore Gi Tubing And Cable Etc Complete All As Specified And Directed.Note: Gi Pipe Shall Be Measured And Paid Seperately Under Relevant Item.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
7.
Housing Urban and Rular Development #11432190 Price Bid
Tender for 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq M On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. - All Kinds Of Soil , 2.25Filling Available Excavated Earth (Excluding Hard Rock/Ordinary Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. , 2.27Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , 4.1.4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1 :2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mmnominal Size) , 4.17Making Plinth Protection 50 Mm Thick Of Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand (Zone-Ill) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level [ 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) ] , 5.33.1.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.33.2.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.22.6Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.9.1Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases For Columns , 5.9.5Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.21Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , 6.1.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 7.1.1Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1 :6:12 (1 Cement: 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 8.14.4.1Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1 :2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :White Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 70 Mm Thick , 8.25.1Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 40 Mm Thick , 8.25.4Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 12 Mm Thick , 10.16.1Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , 10.25.1Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , 11.41.2Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , 12.34Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg I M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm)@ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , 12.50Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , 12.51.2 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Flashings/ Aprons.( Upto 600 Mm) , 12.51.6 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Gutter (600 Mm Over All Girth) , 13.50.2Applying Priming Coat: With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood , 13.50.3Applying Priming Coat: With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , 13.62.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , 13.68.1French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , 16.69 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer In-Charge (Length Of Finished Kerb Edging Shall Be Measured To Calculate Volume For Payment). (Precast cement concrete Kerb Stone Shall Be Approved By Engineer-In-Charge). , 16.92Providing And Fixing 10X10x7.50 Cm Granite Stone Block Hand Cut And Chisel Dressed On Top, For Paving In Floors, Drains Etc. Laid Over 20 Mm Thick Base Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints 10 Mm Wide Filled With Same Mortar Including Ruled Pointing Etc. Complete As Per Direction Of Engineer-In-Charge. , 1-2Excavationinfoundationfor Retaining,Breastwallsetc, Inall Typesofsoils And Rocks Includingall Lead, Lift Anddisposal Of Surplusmaterial Asper Direction Of Engineer- In- Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , 1-4 Randomrubblestonemasonry Laid In1:6Cement Andsandmortar, In Breastwalls,Retainingwalls,Parapets,Scuppers,Etc. Includingsupplyofall Material, Labour, T&Pand Royaltiies Etc. Complete As Per Drawingand Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , 1-3 Randomrubblestonemasonry Laiddry, Inbreastwalls, Retainingwalls, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Completeasper Drawingand Technical Specificationsclauses702, 704, 1202 & 1203 Of Mord Specifiction , 1-5 Handpackedstonefillinginbackofwallls Includingcostofallmaterials, Royality,T&Petc.Completeasperdirectionofengineer-In-Charge. (Asper Pwd Uttarakhand Specifications) , 2-2Concretewithcement, Coarsesandand40mmgaugestoneballast In Proportion1:4:8 In Foundationsand Floors Includingsupplyof Allmaterial, Labour Andt&Petc. Required For Proper Completionof Thework. Asper Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , 3-7Removal Of Unsuitable Soil With Disposal Upto 1000 M Removal Of Unsuitable Soil Including Excavation, Loading And Disposal Upto 1000 M Lead But Excluding Compaction Ground Supporting Embankment Subgradereplacement By Suitable Soil, Which Shall Be Paid Separately As Per Clause 303.5.2As Per Technical Specification Clause 302.3.11 , 12-9Providing Weepholes In Brick Masonry/Stone Masonry, Plain/Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Providing & Supplying Of 25W Self Ballasted Led , Providing & Supplying Of Decorative Lighting Pole Of 4M , Providing & Fixing Of Aayush Wellness Based Signages/Boards Including Vertical Pole & Ms Sheet , Providing & Fixing Of Aayush Wellness Based 3D Paintings With Pop Texture Including Texture Paint
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
9.
Power #11419246 AOC
Tender for (A) Supply Part-11/.4 Kv 400 Kva Distribution Sub Station , 11/.4 Kv 400Kva Dtr (Rec Sep. Ord 11/1976 , providing St Pole Pole 9 Mtr. Long W/L 220Kgs , Muff For Steel Tubular Pole With Concrete Filling , X-Arm: [Channel Iron (100X50x5 Mm), Length : 2800 Mm X 2 Nos] For Incomer Line , Ms A.I.(50X50x6 Mm), Length: 2800 Mm X(1 Nos For Las ) , X-Arm: [Channel Iron (75X40x5 Mm), Length : 2800 Mm X 4 Nos] For Supporting Do Fuse Unit & Go Switch , X-Arm: [Channel Iron (100X50x6 Mm), Length : 2800 Mm X 2 Nos] For Transformer Bed , X-Arm [Channel Iron (100X50x6 Mm), Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer] , Ms A.I.(50X50x6 Mm), Length: (2800 Mm) X 2 No. , Ms Angle Iron (35X35x5 Mm), Length : 460 Mm X 2 Nos , Ms A.I.(50X50x6 Mm), Length: (950 Mm) X 2 Nos. Of Bed Knee Bracing , Ms Angle Iron (50X50x6 Mm), Length : (2800 Mm) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.I. Wire For Earthing , Ms Angle Iron (50X50x6 Mm), Length : (450 Mm)X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O. Switch Handle Supporting: [C.I. (75X40x6mm), Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O Ab Switch Unit (11Kv,400,663Ka) Tripple Pole O/D Type , D.O Fuse Unit , Surge Arrester, 9 Kv Station Class , Discs Insulator Sets (Comp. 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) I/C Dead End Clamps Etc.) , Stay Set Complete , Stay Wire (7/3.15Mm)( 10 Kg Per Stay Set) , Pipe Earthing With Gi,Charcoal & Salt , providing Lt Distribution Panel With Acb (630 A, 50 Ka, 4P,1 No.) & Sfu (100 A 6 No. Rewireble) For 400Kva Trf. As Per Specification , Half Clamp (M.S. Flat 50X6) , Full Clamps (M.S. Flat 50X6) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Aluminium Thimbles 300 Mm Sq. , Copper Thimble 95 Mm Sq. , Danger Plate , Barbed Wire (Rec Sp F 3/1981) , Lt Cable 3-1/2 Core-400 Mm Sq.For Incomer , Lt Cable 3-1/2 Core-185Mm Sq.X6 O/G , Alluminium Paint , Prov.Acsr, 6/1/3.35 Mm , Chain Link Fencing , Angle Iron, Gate Etc. For Transfromer Fencing , providing Transformer Bed Plinth For 1X400kva S/Stn Structure Complete With cement concrete 1:6:12 R.R. Massonery & Plastering Etc. A/W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. , Lt Switched Capacitors 50 Kvar For 400 Kva T/F , Hp Monochrome Laser Printer (A4) Hp Laser 108A With Prints Up To 20 Ppm, 64 Mb Ram 600X600 Dpi Print Resolution 150 Sheets Paper Tray Caapcity Usb 2.0 Port -One Year Warranty , (A) Erection Part-11/.4 Kv 400 Kva Distribution Sub Station , 11/.4 Kv 400Kva Dtr (Rec Sep. Ord 11/1976 , providing St Pole Pole 9 Mtr. Long W/L 220Kgs , Muff For Steel Tubular Pole With Concrete Filling , X-Arm: [Channel Iron (100X50x5 Mm), Length : 2800 Mm X 2 Nos] For Incomer Line , Ms A.I.(50X50x6 Mm), Length: 2800 Mm X(1 Nos For Las ) , X-Arm: [Channel Iron (75X40x5 Mm), Length : 2800 Mm X 4 Nos] For Supporting Do Fuse Unit & Go Switch , X-Arm: [Channel Iron (100X50x6 Mm), Length : 2800 Mm X 2 Nos] For Transformer Bed , X-Arm [Channel Iron (100X50x6 Mm), Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer] , Ms A.I.(50X50x6 Mm), Length: (2800 Mm) X 2 No. , Ms Angle Iron (35X35x5 Mm), Length : 460 Mm X 2 Nos , Ms A.I.(50X50x6 Mm), Length: (950 Mm) X 2 Nos. Of Bed Knee Bracing , Ms Angle Iron (50X50x6 Mm), Length : (2800 Mm) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.I. Wire For Earthing , Ms Angle Iron (50X50x6 Mm), Length : (450 Mm)X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O. Switch Handle Supporting: [C.I. (75X40x6mm), Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O Ab Switch Unit (11Kv,400,663Ka) Tripple Pole O/D Type , D.O Fuse Unit , Surge Arrester, 9 Kv Station Class , Discs Insulator Sets (Comp. 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) I/C Dead End Clamps Etc.) , Stay Set Complete , Stay Wire (7/3.15Mm)( 10 Kg Per Stay Set) , Pipe Earthing With Gi,Charcoal & Salt , providing Lt Distribution Panel With Acb (630 A, 50 Ka, 4P,1 No.) & Sfu (100 A 6 No. Rewireble) For 400Kva Trf. As Per Specification , Half Clamp (M.S. Flat 50X6) , Full Clamps (M.S. Flat 50X6) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Aluminium Thimbles 300 Mm Sq. , Copper Thimble 95 Mm Sq. , Danger Plate , Barbed Wire (Rec Sp F 3/1981) , Lt Cable 3-1/2 Core-400 Mm Sq.For Incomer , Lt Cable 3-1/2 Core-185Mm Sq.X6 O/G , Alluminium Paint , Prov.Acsr, 6/1/3.35 Mm , Chain Link Fencing , Angle Iron, Gate Etc. For Transfromer Fencing , providing Transformer Bed Plinth For 1X400kva S/Stn Structure Complete With cement concrete 1:6:12 R.R. Massonery & Plastering Etc. A/W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. , Lt Switched Capacitors 50 Kvar For 400 Kva T/F , Hp Monochrome Laser Printer (A4) Hp Laser 108A With Prints Up To 20 Ppm, 64 Mb Ram 600X600 Dpi Print Resolution 150 Sheets Paper Tray Caapcity Usb 2.0 Port -One Year Warranty , (B) Supply Part-Ct/Pt Unit 400 Kva Trf. (1 Nos.) , providing 11Kv Ct-Pt Unit Ct/Pt Combined Unit 11 Kv /110V 50/5 A , Prov, Energy Meter (3 Phase, 4 Wire) Ht Ct Type For Above , Pvc Multistrand 2.5 Mm Sq. Copper Wire , 1 Inch Dia Gi Pipe For Concealin , Bend Joints /Elbow , X-Arm: [Channel Iron (75X40x6 Mm), Length : 2800 Mm X 2 Nos] For Supporting Main Channel For Ct-Pt Unit , Ms Angle Iron (50X50x5 Mm), Length : 2800Mmx 4 Nos. , Ms Angle Iron (35X35x5 Mm), Length : 2800Mmx 2 Nos. , Half Clamp (Ms Flat 50X6 Mm) , Full Clamp (Ms Flat 50X6 Mm) , Nut & Bolts Off Size , Aluminium Thimble , Copper Thimble , (B) Erection Part-Ct/Pt Unit 400 Kva Trf. (1 Nos.) , providing 11Kv Ct-Pt Unit Ct/Pt Combined Unit 11 Kv /110V 50/5 A , Prov, Energy Meter (3 Phase, 4 Wire) Ht Ct Type For Above , Pvc Multistrand 2.5 Mm Sq. Copper Wire , 1 Inch Dia Gi Pipe For Concealin , Bend Joints /Elbow , X-Arm: [Channel Iron (75X40x6 Mm), Length : 2800 Mm X 2 Nos] For Supporting Main Channel For Ct-Pt Unit , Ms Angle Iron (50X50x5 Mm), Length : 2800Mmx 4 Nos. , Ms Angle Iron (35X35x5 Mm), Length : 2800Mmx 2 Nos. , Half Clamp (Ms Flat 50X6 Mm) , Full Clamp (Ms Flat 50X6 Mm) , Nut & Bolts Off Size , Aluminium Thimble , Copper Thimble , (C) Supply Part-New Ht Line (2.43 Kms. With Acsr 6/1/3.35 Mm Sq. On Steel Poles , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 11 Mtr. Long W/L 227 Kgs/M2 (With Ruling Span 90M, 8 No. Run Through And 3 No. Double Pole Dead End Structure , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole (2000Mm Long) With Concrete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length 1270 Mm (I/C Tolerence Of 100Mm Either Side) X2 Structure( Run Through Structure (Formation Tringle) , Angle Iron (50X50x5 Mm), Length (2X750) Mm X 1 Structures (Run Through Structure (Formation Tringle) , Pole Top Bracket [Msci:100X50x6mm-100Mm] , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure (Run Through Structure (Formation Tringle) , Belt Set - Ms Angle Iron: 50X50x6, Length [1800 Mm X 2 No.]For Dead End Structures , X-Bracing Set - Ms Angle Iron: 50X50x6, Length [2125 Mm X2 No.] For Dead End Structures , X-Arm(Horizental) - Ms C. Iron: 50X50x6, Length [2340 Mm X2 No.]For Dead End Structures , Discs Insulator Sets On Dead End Structures (Comprising 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) Including Dead End Clamps Etc.) X (3 No. Conductors) X (2 No. Sides)For Dead End Structures , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure For Dead End Structures , Stay Set Complete In All Respect I/C Clamp ( Single Pole-1No. , /D. Pole Structures-4Nos.) , Stay Wire (7/3.15 Mm) (9.0 Kg Per Stay Set) , G.I. Wire , Eye Hook For Earth Wire , Earth Wire Clamp , Ht Earthing Set Complete (Rec construction Standared J-1) , Half Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Full Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Danger Plate (250X200x1.6 Mm) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Barbed Wire (Rec Sp F 3/1981) , G.O Ab Switch Unit (11Kv,630 A,25Ka) , D.O Fuse Unit , M.S. C.I. 2400 Mm For Road Crossing (75X40x6mm) , Alluminium Paint , (C) Erection Part-New Ht Line (2.43 Kms. With Acsr 6/1/3.35 Mm Sq. On Steel Poles , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 11 Mtr. Long W/L 227 Kgs/M2 (With Ruling Span 90M, 8 No. Run Through And 3 No. Double Pole Dead End Structure , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole (2000Mm Long) With Concrete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length 1270 Mm (I/C Tolerence Of 100Mm Either Side) X2 Structure( Run Through Structure (Formation Tringle) , Angle Iron (50X50x5 Mm), Length (2X750) Mm X 1 Structures (Run Through Structure (Formation Tringle) , Pole Top Bracket [Msci:100X50x6mm-100Mm] , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure (Run Through Structure (Formation Tringle) , Belt Set - Ms Angle Iron: 50X50x6, Length [1800 Mm X 2 No.]For Dead End Structures , X-Bracing Set - Ms Angle Iron: 50X50x6, Length [2125 Mm X2 No.] For Dead End Structures , X-Arm(Horizental) - Ms C. Iron: 50X50x6, Length [2340 Mm X2 No.]For Dead End Structures , Discs Insulator Sets On Dead End Structures (Comprising 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) Including Dead End Clamps Etc.) X (3 No. Conductors) X (2 No. Sides)For Dead End Structures , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure For Dead End Structures , Stay Set Complete In All Respect I/C Clamp ( Single Pole-1No. , /D. Pole Structures-4Nos.) , Stay Wire (7/3.15 Mm) (9.0 Kg Per Stay Set) , G.I. Wire , Eye Hook For Earth Wire , Earth Wire Clamp , Ht Earthing Set Complete (Rec construction Standared J-1) , Half Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Full Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Danger Plate (250X200x1.6 Mm) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Barbed Wire (Rec Sp F 3/1981) , G.O Ab Switch Unit (11Kv,630 A,25Ka) , D.O Fuse Unit , M.S. C.I. 2400 Mm For Road Crossing (75X40x6mm) , Alluminium Paint , (D) Supply Part-Three Phase Lt Line With Aaac 6/1/3.35 Mm Sq. On Steel Poles(0.830 Km) 3-Phase 4 Wire Double Circuit Line , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole , Shackle Insulators (16Kn) (Recd-3/761)(Iss No 1445/1977) , D-Iron (U-Clamp) (Recd-4/79)(Iss No 7935/1975) , Lt Saty Set Complete Rec No 31/1983 , Stay Wire (7/3.15 Mm) (8.0 Kg Per Stay Set) , providing Full Clamp , Earthing Set , G.I.Wire No 8 Swg Earth Wire 1.03Km (Sep.G-2/72) For Suporting Cable , M.S.Nuts & Bolt Off Sizes , C.I. 75X40x6mm (Length 2400X2 Mm) For Centilever Double Circuit Line , Aluminium Paint , (D) Erection Part-Three Phase Lt Line With Aaac 6/1/3.35 Mm Sq. On Steel Poles(0.830 Km) 3-Phase 4 Wire Double Circuit Line , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole , Shackle Insulators (16Kn) (Recd-3/761)(Iss No 1445/1977) , D-Iron (U-Clamp) (Recd-4/79)(Iss No 7935/1975) , Lt Saty Set Complete Rec No 31/1983 , Stay Wire (7/3.15 Mm) (8.0 Kg Per Stay Set) , providing Full Clamp , Earthing Set , G.I.Wire No 8 Swg Earth Wire 1.03Km (Sep.G-2/72) For Suporting Cable , M.S.Nuts & Bolt Off Sizes , C.I. 75X40x6mm (Length 2400X2 Mm) For Centilever Double Circuit Line , Aluminium Paint
Contract Date: Jun 30, 2026 Contract Value : 37.28 Lakh
Government Departments No of Bidders 7
Himachal Pradesh View Result →
10.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : 49.60 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.73 Crore
Government Departments No of Bidders 1
15.
Public Administrative Department #11355718 AOC
Tender for Annual Tender 2026-27 Supply Of Electrical Goods For The Year 2026-27 , 4 Feet Flourescent Tube Light , 36W / 40W Tubelight Electronic Choke , Tube Light Side Lock Holder , Insluation Gum Tape Roll - Isi , 1/18 Vir Copper Wire [1/44] [90Mtr] , 3/20 Cts Copper Wire [3/36] [90Mtr] , 7/20 Cts Copper Wire [7/34] [90Mtr] , 7/16 Cts Copper Wire [7/67] [90Mtr] , 19/16 Cts Copper Wire [19/51] [90Mtr] , 1.5 Sq.Mm 3 Core Copper Cable , 2.5 Sq.Mm 3 Core Copper Cable , 4 Sq.Mm 3 Core Copper Cable , 6 Sq.Mm 3 Core Copper Cable , 10 Sq.Mm 3 Core Copper Cable , 16 Sq.Mm 3 Core Copper Cable , Led Fitting Top Protection Glass - Street Light , Led Fitting Top Protection Glass - Flood Light , 32 / 40 Mm 1 No Gi Bend Pipe, With 2Nos Of Pole Clamps With Bolts And Nuts , 6Amps To 32 Amps Sp Mcb , 40Amps 2Pole Isolator , 63Amps 4Pole Isolator , 32A D.P Switch , Mcb Box , Fuse Unit 16 Amps 240V , Fuse Unit 32 Amps 415V , Fuse Unit 63 Amps 415V , Fuse Unit 100 Amps 415V (Heavy Duty) , Fuse Unit 200 Amps 415V (Heavy Duty) , Fuse Unit 300 Amps 415V (Heavy Duty) , Fuse Unit 400 Amps 415V (Heavy Duty) , Fuse Unit 500 Amps 415V (Heavy Duty) , Main Switches Spn 32 Amps , Main Switches Tpn 32 Amps , Main Switches Tpn 63 Amps , Main Switches Tpn 100 Amps , Main Switches Tpn 315 Amps , 63A 4Pmc Changeover Switch , 100A 4Pmc Changeover Switch , Automatic On/Off Street Light Timer Switch With 24Hrs 7 Days Programable Digital Timer Clock, 40 Amps 4 Pole Contactor With Coil, Mcb Switch And Connector Fully Wired With All Accessories , Street Light Meter/Main Box With Wooden Board, Main Switch, Fuse Carrier Fully Wired With All Accessories , Electronic 7 Days 24 Hrs Programable Ditial Timer Clock , 63 Amps 4 Pole Contact With Coil , 220V - 250V Contactor Coil , Power Capacitor , 9W Led Bulb , 20W High Bright Led 4 Feet Light , 20W Led Power Saver Street Light Fitting , 25W Led Power Saver Street Light Fitting , 30W Led Power Saver Street Light Fitting , 36W Led Power Saver Street Light Fitting , 50W Led Power Saver Street Light Fitting , 60W Led Power Saver Street Light Fitting , 72W Led Power Saver Street Light Fitting , 90W Led Power Saver Street Light Fitting , 150W Led Power Saver Flood Light Fittings , 200W Led Power Saver Flood Light Fittings , 60W All-In-One Solar Led Street Light Fittings , 80W All-In-One Solar Led Street Light Fittings , 18W To 25W Led Chip Board , 30W To 36W Led Chip Board , 45W To 60W Led Chip Board , 72W To 90W Led Chip Board , 120W To 200W Led Chip Board , 18W To 25W Led Heavy Duty Electronic Driver , 30W To 36W Led Heavy Duty Electronic Driver , 45W To 60W Led Heavy Duty Electronic Driver , 72W To 90W Led Heavy Duty Electronic Driver , 120W To 200W Led Heavy Duty Electronic Driver , 10 Kv Surge Protector , 48 Ceiling Fan With All Accessories , D.O.L Motor Starter Up-To 10 Hp , G.I Swaged Tubler 6 Meter Pole With 60W All-In-One Solar Street Light Model Fitting With One Year Warranty, [All-In-One Model Includes 100W Solar Panel, 60W Led Mcpcb, In-Built Li-Thium Battery, Dusk To Dawn Driver Controller, Sensor, Heavy Duty Clamping Arm In A Suitable Ip65 Rated Enclosure] , 10Metre Hot Dip Galvanised Octogonal Pole With Round Ring Arm And 4Nos Of Strong 5Feet Anchor Bolts, Templates, And Nuts Etc.. Complete Set , 1 Hp To 3Hp Single Phase Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 5 Hp To 7.5Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 10 Hp To 25Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , Service Charges Automatic On/Off Street Light Timer Switch Box , Service Charges For Mini Mast Lighting System , Service Charges For High Mast Lighting System
Contract Date: Jun 24, 2026 Contract Value : 3.87 Lakh
Local Bodies No of Bidders 2
16.
Drinking Water Supply and Sanitation #11348134 Technical Bid
Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
17.
Petroleum and Natural Gas #11346768 AOC
Bids Are invited for Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A-1) 4 core 4 Sq. mm , Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. (a) 3 core 2.5Sq. Mm , Laying of XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (G) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core) , Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (C) 4 core 25 Sq. mm , Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. (D) 3 core 10 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (a) 2 to 4 core 2.5/ 4 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (A)3 core 2.5 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (E) 4 core 25 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (c) 3 core 10 Sq. mm , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A)4Sq.mm , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 2.5 Sq.mm , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (D) 25 Sq.mm. , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 10 Sq.mm , Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground. , Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground. , Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks per meter) , Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50 K.A. and above at 415 V having Normal current rating 400A with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing [ ICS=100% of ICU only, Cat III] , Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. , Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , Disconnecting the cable connection and Providing straight joint with PVC mould using heat shrink /cast resin type epoxy compound Insulating material and making the joint complete using necessary in line connectors, hardener, earth continuity connection, spacers etc. and reconnecting the same & ensure the joint resistance within the limits as per IS. (B)3.5C 50 Sq. mm cable. , Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge.(5) 300 X 50 X 2.0 mm Thick , Providing and fixing approved make 90° Elbow for Perforated C type cable tray. Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge. (5) 300 X 50 X 2.0 mm Thick 90° Elbow , Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge. (2) 100 X 50 X 1.6 mm Thick , Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. , Providing cement concrete.for foundation or for concrete filling in 1:2:4 ratio with 20 to 25 mm stone metal duly plastered with necessary curing for pole muffing or any other purpose.
Contract Date: Ref. Documents Contract Value : 9.58 Lakh
Boards / Undertakings / PSU No of Bidders 4
18.
Defence #11344413 Technical Bid
Tender for Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out In Hard/Dense Soil, Complete All As Specified And Directed. , Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Hard/Dense Soil Complete All As Specified And Directed. , Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And Directed. , Excavating In Post Holes Each N Exc 0.5 Cum Getting Out, Returning Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceedings 25Cm Watering And Removing Surplus Soil To Distance N Exc 50 M And Making Good Surface In Hard/Dense Soils Complete All As Specified And Directed. , Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point, Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc 15Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed By Engr-In-Charge. , Dismantling Timber Scantling 40 Sqcm And Over In Section In Any Position Framed Work, Complete All As Specified And Directed By Engr-In-Charge. , Dismantling Unframed Work In Fillets, Rails, Posts, Rafters, Purlins Etc Under 40Sqcm In Section, Complete All As Specified And Directed By Engr-In-Charge. , Dismantling Boarding Any Description, Fixed With Any Position With Nails, Complete All As Specified And Directed By Engr-In-Charge. , Dismantling Plain Or Corrugated Steel Sheeting, Any Gauge, Thickness Including Nanital Pattern Or Similar Pattern Roof Covering, Complete All As Specified And Directed By Engr-In-Charge. , M&L For Hardcore Of Gauge N Exc. 63 Mm Of Broken Stone Or Boulders, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface, Complete All As Specified And Directed. , M&L For Cement Concrete 1:4:8 Type D2 (40 Mm Graged Aggregate) As In Foundation And Filling Mass Concrete Complete All As Specified And Directed By Engr-In-Charge. , M&L For Plain Cement Concrete Type C2, 1:3:6 (40Mm Graded Aggregate) (M-10) As In Foundation , Filling And Mass Concrete And Similar Work , All As Specified And Directed. , M&L Foer Plain Cement Concrete Type B2, 1:2:4 (40Mm Graded Stone Aggregate) As In Foundations, Filling And Mass Concrete, Complete All As Specified And Directed. , M&L For Type C1, 1:3:6 (20Mm Graded Aggregate) Pre-Cast Cement Concrete Block Masonry With Solid Blocks, Exc. 10 Cm In Width And Setting In Mortar, Complete Complete All As Specified And Directed. , M&L For Type B1, 1:2:4 (20Mm Graded Aggregate) Pre-Cast Cement Concrete With Hollow Block Masonry, Exc. 10 Cm In Width And Setting In Cm 1:6, Complete Complete All As Specified And Directed By Engr-In-Charge. , M&L For Reinforced Cement Concrete (Nominal Mix) Type B1, 1:2:4 (20Mm Graded Aggregate) As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And Directed By Engr-In-Charge. , M&L For Reinforced Cement Concrete (Nominal Mix) Type B1, 1:2:4 (20Mm Graded Aggregate) As In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span Complete All As Specified And Directed By Engr-In-Charge. , M&L For Reinforced Cement Concrete (Nominal Mix) Type B1, 1:2:4 (20Mm Graded Aggregate) As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And Directed By Engr-In-Charge. , Use And Waste Flat Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter Complete All As Specified And Directed By Engr-In-Charge. , Use And Waste Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Sup- Ports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. Complete All As Specified And Directed By Engr-In-Charge. , Use And Waste Square, Rectangula Or Polygonal Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And Directed By Engr-In-Charge. , M&L For Second Class Hard Wood In Scantling, Clean Sawn, Timber Framed And Fixed, Complete All As Specified And Directed By Engr-In-Charge. , S&F 2Nd Class Hardwood Plain, Solid, Straight Chowkats And Frames, Wrought Framed Rebated On The Solid, Rounded Or Chamfered Put Together With Glue Pinned At Joints, Complete All As Specified And Directed By Engr-In-Charge. , S&F 30Mm Thick 2Nd Class Hardwood, Glazed And Skelton Shutters, Open Rebated And Prepared To Receive Glass, Gauze Etc (Without Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc Size Of Members Of Shuters As Specified In Ssr Part-I, Section 8, Clause 8.24(A), Fittted To Chowkats, Complete All As Specified And Directed By Engr-In-Charge. , S&F 30Mm Thick 2Nd Class Hardwood, Plain Framed, Framed, Panelled Shutter (Any Number Of Panels) With Panels Of Timber Flat On Both Sides (Feather Edged) Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers Fitted To Chowkats, Complete All As Specified And Directed By Engr-In-Charge. , Taking Down Chowkhats With Shutters (Without Taking Off Shutters From The Frame) Not Exc 1.5 Sqm Each, Complete All As Specified And Directed By Engr-In-Charge. , Taking Down Chowkhats With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4.00 Sqm Each, Complete All As Specified And Directed By Engr-In-Charge. , Taking Down Wall/Ceiling Panelling And Similar Work Complete All As Specified And Directed By Engr-In-Charge. , S&F Pvc Wall Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheet Inclusive Of Solvent Cemtn And Fixing At Sit Eon Pvc Frame As Per Specifications And Drawing, Complete All As Specified And Directed By Engr-In-Charge. , S&F 5Mm Thnick Pvc Sheet Fillet Of Width 35Mm For Wall Panelling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing Complete All As Specified And Directed By Engr-In-Charge. , S&F 100Mm Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And Fixed, Complete All As Specified And Directed By Engr-In-Charge. , S&F 200Mm Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And Fixed, Complete All As Specified And Directed By Engr-In-Charge. , S&F 250Mm Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed, Complete All As Specified And Directed By Engr-In-Charge. , S&F 75Mm Butt Hinges, Mediam Weight, Cold Rolled Mild Steel And Fixed Complete All As Specified And Directed By Engr-In-Charge. , S&F 125Mm Butt Hinges, Mediam Weight, Cold Rolled Mild Steel And Fixed Complete All As Specified And Directed By Engr-In-Charge. , S&F 100Mm Aluminium Handles, Cast Type, Anodised Complete All As Specified And Directed By Engr-In-Charge. , S&F 150Mm Aluminium Handles, Cast Type, Anodised Complete All As Specified And Directed By Engr-In-Charge. , S&F Mild Steel Work As Hand Rails, Half Round Or Other Steel Section Or Core For Wooden Hand-Rail Straight Portion, Drilled And Countersunk For Balusters Running Bars, For Doors, Balusters, Nosing To Steps Including Embeding In Concrete And Screwing Etc. Wind Ties For Roof Including Securing Bolts; Posts And Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.; Flat Iron Fillets (For Securing Wire Mesh Etc.) Including All Necessary Drilling, Bolting Or Riveting, Etc., And Similar Work Conforming To Fe-290 Gde E-165 Complete All As Specified And Directed By Engr-In-Charge. , S&F Bands, Straps, Supports Or Stays For Rainwater, Ventilating Pipes, Including Bolts, If Required Hooks (Stay), Heavy, For Large Gates; Hook And Pintle Hinges: Large Hasps And Staples; Chains; Hand Made Sliding Bolts; Clamps; Hold Fasts; Wall Ties; Hooks For Hanging Fans; Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters; Knee Piece Inserts; Two Way And Three Way Straps, Plate Washers And Similar Small Articles Conforming To Fe-290 Gde-E-165, Complete All As Specified And Directed. , S&F Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed By Engr-In-Charge. , S&F Mild Steel Tmt Bars 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed By Engr-In-Charge. , S&F Rolled Mild Steel Plate Girder Or Single Stanchions Built Up Of One Beam Or Channel Section With Flange Plates, Caps, Bases, Splices, Angle Brackets, Cleats And Other Connections Conforming To Fe-290Complete All As Specified And Directed. , S&F For S&F Steel Work In Tubular Trusses Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161 1979 Grade St.-240, Complete All As Specified And Directed. , S&F 0.63Mm Thick Galvanised, Corrugated Mild Steel Sheeting With Two Corrugations Side Lap,Fixed With Coach Screws And Washers In Roof, Walls Etc With Grade Of Zinc Coating 275, Complete All As Specified And Directed By Engr-In-Charge. , S&F 0.80Mm Thick Plain, Galvanised, Mild Steel Sheeting, In Ridges, Hips, Valley Gutters, Drip And Straight Flashings (Length And Girth As Fixed) With Grade Of Zinc Coating 275, Complete All As Specified And Directed By Engr-In-Charge. , S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/ Cladding To Wall Fixed With Self Tapping Screws As Specified, Complete All As Specified And Directed. , S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/ Cladding To Wall Fixed With Self Tapping Screws As Specified, Complete All As Specified And Directed. , M&L For 3Mm Thick Cover Fillet Of Standard Hard Board, 40Mm Wide And Fixing With Screws Complete All As Specified And Directed By Engr-In-Charge. , M&L For 6Mm Thick Plywood, Grade Bwr, Type Bb, Fixed With Nails To Timber Frame Work (05 No Of Ply), Complete All As Specified And Directed By Engr-In-Charge. , M&L For 4Mm Thick Plywood, Grade Bwr, Type Bb, Fixed With Screws To Timber Frame Work In Ceiling, Complete All As Specified And Directed By Engr-In-Charge. , M&L For 75Mm Thick Plain Cement Concrete 1:3:6 Type C2 (40Mm Graded Aggregate) As In Plinth Protection Complete All As Specified And Directed. , M&L For 75Mm Thick Cement Concrete 1:4:8 Type D2 (40 Mm Graged Aggregate) As In Sub Base Or Flooring Complete All As Specified And Directed By Engr-In-Charge. , M&L For 100Mm Thick Cement Concrete Type D2, 1:4:8 (40Mm Stone Aggregate) As In Floors Or Sub Base, Complete All As Specified And Directed. , M&L For 25Mm Thick Plain Cement Concrete Type B1 1:2:4 (20Mm Graded Aggregate) As In Floors, Complete All As Specified And Directed. , M&L For 40Mm Thick Plain Cement Concrete Type B-0, 1:2:4 (12.5Mm Graded Aggregate) As In Floors, Complete All As Specified And Directed. , M&L For Glazed Ceramic Coloured Tiles In Vertical Surface 350X 250X 7Mm/ 450X 350X 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Complete All As Specified And Directed By Engr-In-Charge. , M&L For Non - Skid Ceramic Coloured Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engr-In-Charge. , M&L For Non - Skid Ceramic Coloured Tiles 7 To 8 Mm Thick(Square/Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engr-In-Charge. , M&L For Virified Ceramic Tiles 10 Mm Thick, Light Shade (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engr-In-Charge. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises, Complete All As Specified And Directed. , M&L For Rendering 10Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cm 1:4 As Backing Coat Complete All As Specified And Directed. , M&L For Rendering 15Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cm 1:4 Complete Complete All As Specified And Directed. , M&L For Screed Bed Or Bedding Layer Of Mortar 15Mm Thick For Laying Floor Finishes In Cm 1:6, Complete All As Specified And Directed. , Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc.Complete All As Specified And Directed. , M&L For Preparation Of New Plastered Surface Of Wall And Applying Two Coat Of Cement Base Paint Over A Coat Of Alkali Resistance Priming Paint Complete All As Specified And Directed. , M&L For Preparation Of New Plastered Surface Of Wall And Applying Two Coat Of Obd Over A Coat Of Priming Plastered And Other Surfaces With Alkali Resistant Priming Paint Complete All As Specified And Directed. , S&F 4Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.5 Sq. M In Each Pane Complete All As Specified And Directed. , M&L For Preparation Of Old Wooden Surfaces Of Any Description, Over 10Cm In Width Or Girth,Not Otherwise Described And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. , M&L For Preparation Of New Or Previously Untreated Wooden Surfaces Of Any Description, Not Otherwise Described Over 10Cm Width Or Girth, And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed By Engr-In-Charge. , M&L For Preparation Of Old Steel Surfaces Of Any Description, Over 10Cm In Width Or Girth,Not Otherwise Described And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. , M&L For Preparation Of New Or Previously Untreated Steel Surfaces Of Any Description, Not Otherwise Described Over 10Cm Width Or Girth, And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide, Zinc Crome Complete All As Specified And Directed By Engr-In-Charge. , Taking Down Of Electrical Switch Board Of Any Size/Tube Light/Ceiling Rose/Holder And Refixing After And Over Wall Panelling Complete All As Specified And Directed. , M/L For Point Wiring In Casing Caping With 1.5Sq Mm Frls Pvc Insulated Unsheathed Single Core Multithreaded Copper Conductor Cable 1100 Volts Grade Incl 1.5 Sq Mm Pvc Insulated Unsheathed Copper Conductor Cable As Earth Continuity Conductor Drown Through In And Incl Casing Caping With Its Accessories Pressed Steel Terminal Box Incl 3Mm Thick Isi Marked Laminated Sheet Cover For Fixing Switches/Socket/Regulators Etc For The Following: - One Light/Fan Point Controlled By One No Piano Type Switch 5 Amps Single Pole One Way , One Socket Outlet 5/3 Pin 6 Amps Controlled By One Switch On The Same Board. , One Socket Outlet 5/3 Pin 6 Amps Controlled By One Switch On Independent Board. , All As Per Item No 1 Above But One 3 Pin Socket Out Let 15/16 Amps With Three Nos Single Core Unsheathed Pvc Insulated Cable Multistranded Copper Conductor Of Size 2.5 Sq Mm For Phase, Neutral & Earth Continuity Conductor. , S&F Switch Piano Flush Button Single Pole One Way 5/6 Amp. , S&F Switch Socket Combination 2 In 1, 3 Pin, 6 And 16 annual periodical maintenance Flush Type Universal , S&F Switch Socket Combination 2 In 1, 6A Flush Type , S&F Ceiling Rose Surface Bakelite 65Mmx50mm 10 Watt Three Terminal. , S&F Sheet Metal Enclosure Double Door For Mcb Db Single Pole And Neutral 8 Way With 200 Amps Rated Bus Bar 240 Volts Double Door (Metallic) Type Including Taking Down Old Unserviceable Mcb Db With Mcbs. , S&F Mcb Spn 32 Amps 240 Volts C Series, 10 Ka, 50 Hz. Make:- As Approved Make Of Db , S&F Mcb Sp 5 To 32 Amps 240 Volts C Series, 10 Ka, 50 Hz Including Connection In The Db And Testing/Commissioning. Make:- As Approved Make Of Db , Supply And Fixing Led Lights Fitting 1X 18W, 4 Feet, 220V,Ac Decorative Box Type With Driver, Holder Including Led Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete. , Supply And Fixing Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, 220 V Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete. , Supply And Fixing Led Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65/66 Protection Complete. , Supply And Laying Or Fixing Or Passing Through Pipexlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade Of Size 16 Sqmm 2 Core Complete Including Taking Out Old Unserviceable Cable All As Specified And Directed By Engineer In Charge. , Supply And Laying Or Fixing Or Passing Through Pipexlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade Of Size 4 Sqmm 2 Core Complete Including Taking Out Old Unserviceable Cable All As Specified And Directed By Engineer In Charge. , S&F Dwc Pipe 63/50Mm Size All As Specified And Directed By Engr-In-Charge. , Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Buried Directly In Ground( Earth Pit Not Less Than 2.25 Meter Deep Below Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, Connected To Galvanised Earth Lead Wire 4.0Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel, All As Shown In Electrical Plate No 3 Of Ssr Pt I Including Necessary Excavation And Earth Work Plain Cement Concrete (1:3:6) Type C-1 With 50 Mm Thick Pre Cast Reinforced Cement Concrete ( 1:2:4) Type B-1 Cover Slab Framed With 50X30x4 Mm Ms Angle (Reinforced With 6 Mm Dia Deformed Bar @ 15 Cm C/C Both Ways And Suitable Handle Of 10 Mm Dia Round Bar) Including Providing Charcoal Or Coke And Magnesium Sulphate In Alternate Layers Of 15 Cm Compacted Thickness All Around The Earth Electrode, With Funnel And 20 Mm Bore Galvanized Iron Watering Pipe (Medium Grade) Wire Mesh, Copper Lugs, Complete In All Respect., Gi Earth Wire Protected By 40 Mm Bore (Light Grade) Galvanized Iron Pipe And Other End Connected To The Earth Bar (Test Point) Made Of Ms Flat (400X32x6 Mm) Bend In ‘D Shape And Fixed To Wall By Means Of Fast Nut Or Bolt Grouted In To Wall At 1 Mtr From Plinth Height. 4Sqmm Pvc Insulated (Colour Green) Copper Conductor Single Run As Earth Continuity Conductor Along With 15 Mm Pvc Conduit Grouted In Wall Or Fixed On Wall Surface To Be Continued Up To Main Switch Board And Fix With Common Earth Dolly As Directed By Eic . Disposal Of Soil To A Distance Not Exceeding 50 Mtr And Necessary Testing On Completion Complete Including Taking Out Old Unserviceable Earthing Materials All As Specified And As Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
19.
Defence #11342816 AOC
Tender For Annual Maintenance Contract Of Existing Earthling Pits Of Technical Infra And Misc Work At Af Stn Awantipur; 1 M&L for Earthing complete with Copper earth plate 600 x 600 x 3.15 mm thick buried directly in ground (earth pit not less that 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mr below normal ground levelconnected to20x3 mm Cu strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washersfrom earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pitpit covers of 300mm x 300 mm made of cast iron including painting as per color coding as per IS,in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified, complete as specifed and directed. 2 Note: (i) Copper strip 7.5 mtr included in the quoted rate from earth pit to test point (ii) Contractor should ensure that result of each earthing is less than 2 Ohm and in case soilis not suitable for the same is to be placed suitable clay soil to bring the desired result. Contractor shall qute rates after site visit accordingly. (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to department. (iv) Work includes brazing work for earth strip. (v) Work includes brazing of Cu strip to copper earth electrode 3 M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground levelconnected to32x6 mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washersfrom earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosureincluding watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and as directed. Note: GI strip 7.5 mtr included in the quoted rate from earth pit to test point. 4 M&L for brazing in repair work for GI strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified. 5 M&L for brazing in repair work for copper strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified. 6 S&F in replacement of saddle/insulator for strip with fixing arrangement in roof/wall of building having configuration upto G+5 for run of strips on it complete all as specified and directed. 7 Refixing only of strip (serviceable strips as obtained from taking down) of any type & size but including saddles/insulators with screws for fixing complete all as specified. 8 S&F aluminium strip 25x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints complete all as specified. 9 S&F copper strip 32 x 6 mm earthing lead laid in trenches/GI pipe for making grid/loop of earthing pit complete all as required at site all as specified and directed by Engr-in-charge. 10 S&F copper strip 20x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing and nut bolts jointing at all joints complete all as specified. 11 S&F galvanized iron strip 25x4 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified. 12 Taking down the existing aluminium/copper strip of any size and type from the top of blast pens/ground/equipment/bldg (roof/down conductor) and keeping in safe custody (for serviceable strips to re-use ) complete all as specified and directed. 13 M&L for Test point terminal block forearthing made of gun metal or phosphorus bronze size 75x75x25mm driled and srewed including 3 nos 8mm dia 25mm long hex head srew,complete as specified and directed. 14 M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type by using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified. 15 M&L for Chemical Earthing cum Maintenance free earthing system complete UL-467 approved copper earth plate 900mmx600mmx5mm( purity above 99%) burried in ground to vertically to a depth not less than 3.5m deep below ground level with top edge earth electrode at a depth not less than 500 mm below normal ground level , provision of copper bus plate of size 200 mm x 25mmx 6 mm for inter connection with copper earth lead strip 32mmx6 mm and further connected to test point terminal block of size 120 mm x 120 mmx 25 mm made of copper as directed by watering pipe light grade with CI/ MSfunnel and wire mesh including excavation earth work in any type of soil and removil surplus soil to a distance not exceeding 50 m only, continuous copper strips/brazing to be used only including 45 Kg (minimum)NABL Lab certified backfill compound marconite for single bore holes soil mixed , alternate layers of conductive concrete resistivity of 0.001 Ohm & carbon based maintenance free compound (20 Kgs bagx5) make as per IEEE 80 2000, Clause 14.5 D Maintenance free earthing system to give earth resistance below 1 Ohms including excavation and earth workand earth to neutral voltage less than 2 volts, PCC chamber of PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate with pit covers of 300mmx 300 mm made of cast iron including painting as per color coding as per IS,complete as specifed and directed. 16 Note:(i) Copper strip 7.5 mtr and their joints included in the quoted rate from earth pit to test point. (ii) Contractor should ensure that result of each earthing is less than 1 Ohm and in case soilis not suitable for the same is to be placed suitable clay soil to bring the desired result. Contractor shall qute rates after site visit accordingly.(iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to department. (iv) Work includes brazing work for earth strip.(v) Work includes brazing of Cu strip to copper earth electrode Make for backfill, conductive concrete- marconite 17 Supply and intallation of advance maintance free tripod ring earthing system by boring the required nos of holes of dimension 8 to 10 inch wide and length of hole should be less than approximately 2 inches of the electrode length in semi hard soil or hard soil consisting of three Nos (UL) 467-2007 or latest as well as IEC 62561listed CPRI tested Pure copper tube earth electrode designed in accordance to IS:3043(1987).The system consists of copper tube earth electrode having purity of 99.99%.There is a copper strip inside it which is pressure filledwith highly conductive crystalline mixture of metal alloys and other conductive material.Both the ends of the electrode should be permanently sealed with the extended terminal having two holes at the top for connecting the earthing system to the equipment/load.The Copper tube earth electrode should beof outer dia 50 mm,thickness of rod 01mm and length 03 mtrs tested according to IEC 62561-2 with minimum 10 years life span (the rod should be marked as per the UL certification ) including min 25 Kgs/electrode of earth enhancing compound (PROCEM) NABL certified, CPRI tested eco friendely tested as per the IEC 62561-7 and needs to be considered to fill the 100 mm bored hole surrounding to the electrode. the earth enhancing compound should have restivity less than 50 ohm-meter with chemically inert to sub soil that should not pollute the envoriment and non corrisiovie to the earth electrode itself. Provision of the connector for connecting electrode with earthing conductor/strip including fastner made of stainless steel/copper/brass as directed having suitable size according to the electrode and earthing conductor dimensions. all the three earthing electrode would be seperated by appropriate distance of not less than 3m and not more than 6m and connected to Each other by and including 25X3mm copper strip to make ring earth and further to be connected to the testpoint and to be buried in appropriate depth not less than 500 mm below the normal ground level and earth pit chamber of suitable size not less than 300mmX300mmX300mm internal dimension made of FRP material complete with flush mounted, removable and locakable cover able to withstand 15kN for Each earth electrode all as directed by engineer in charge.The interconnecting conductor/copper strip shall also be covered with approximately 30 kg of earth enhancing compound for each 3 metres length of strips all to be included in quoted rate itself. The Earth pit inspection chambershould be as perIEC 62561-5 or latest and will be of 300x300x300 mm inside dimension of RCC with 50 mm thick and fine finish.The marking space should be present on RCC Cover.The chamber should have facility for making earth resistance and latst testing date by paint at the cover and previous recorded values inside the cover. Make OBD Bettermann/Fruse/KLK/Erico/True power all as per description of engineer in charge. Note-copper strip of 7.5m length from earthing electrode to the test point and copper strip required for interconnections of rods to make rings of approximately 9metre is included in the quoted rate. 18 Supply and intallation of advance maintance free Single rod earthing system by boring the required nos of holes of dimension 8 to 10 inch wide and length of hole should be less than approximately 2 inches of the electrode length in semi hard soil or hard soil consisting of one Nos UL 467 listed CPRI tested Pure copper tube earth electrode designed in accordance to IS:3043(1987).The system consists of copper tube earth electrode having purity of 99.99%.There is a copper strip inside it which is pressure filledwith highly conductive crystalline mixture of metal alloys and other conductive material.Both the ends of the electrode should be permanently sealed with the extended terminal having two holes at the top for connecting the earthing system to the equipment/load.The Copper tube earth electrode should beof outer dia 50 mm,thickness of rod 01mm and length 03 mtrs tested according to IEC 62561-2 with minimum 10 years life span (the rod should be marked as per the UL certification ) including min 25 Kgs/electrode of earth enhancing compound (PROCEM) NABL certified, CPRI tested eco friendely tested as per the IEC 62561-7 and needs to be considered to fill the 10 inch bored hole surrounding to the electrode. the earth enhancing compound should have restivity less than 50 ohm-meter with chemically inert to sub soil that should not pollute the envoriment and non corrisiovie to the earth electrode itself. Provision of the connector for connecting electrode with earthing conductor/strip including fastner made of stainless steel/copper/brass as directed having suitable size according to the electrode and earthing conductor dimensions..Note-copper strip of 7.5m length from earthing electrode to the test pointis included in the quoted rate.The Earth pit inspection chambershould be as perIEC 62561-5 or latest and will be of 300x300x300 mm inside dimension of RCC with 50 mm thick and fine finish.The marking space should be present on RCC Cover.Make OBD Bettermann/Fruse/KLK/Erico/True power all as per description of engineer in charge 19 Note for item 15 & 16:- (a) the rate shall include excavation of earth,removal of surplus soil and filling with back fill compound etc for completion of the job. (b) earthing resistance result should be less than 2 Ohm. If the result comes more than 2 Ohm, the contractor will be carried out the earthing in seperate location/site or as given by the engineer in charge after taking out of earth electrode all with out any extra cost to the department(c) the contractor willprovide all the required and necessarycertificates as per the specification for required items mentioned above from the same company before incorporting the same in the work as per engineer in charge. and the rep of the company should be avaliable at the site for the installation of the earthing as per their recommendation and specification to obtain the minimum resistance value.(d) testing equipment will be duly tested from authorized goverment.lab/CRPI lab and sealed by the testing authority and produce test certificate of testing equipment before testing for wich no extra payment shall be borne by the department (e) testing of earthing after completionof work will be carried out in presence of the GE, engineer in charge,rep of userand the contractor.(f) contractor/manufacturer will be provided the gurantee for earthing and result for the period of at least Two years. 20 M&L for dismantling of PCC earth pit chamber including excavate the old earthing and making PCC chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC (1:2:4) type B1 including RCC cover with suitable size of handle including excavation and earth work as required at site complete all as specified and directed by the Engineer-in-Charge. 21 S&F in replacement of funnel with wire mesh suitable for each pit as per site requirement complete all as specified and directed. 22 S&F in replacement of RCC cover of earth pit of size as per electrical plate No. 3 of SSR-2009, Part-I complete with suitable handle complete all as specified and directed by the Engineer-in-Charge. 23 M&L for common salt commercial ,for recharging of earthing pits by filling in earthing pits complete all as specified and directed by Engr-in-Charge. (Note:- Recharging materials shall be soluble in water and to be filled/poured in earth pit after mixing in water in appropriate quantity.) 24 M&L for Charcoal dust/Breeze ,etc for recharging of earthing pits by filling in earthing pits complete all as specified and directed by Engr-in-Charge. 25 S&F in replacement of GI tubing 20mm bore medium grade for wateringfrom bottom of earth pit to top of electrodein trenches/floor/fixed along pole/wall forwatering of earthing with proper size of MS clamp, nut, bolts and washers complete all as specified and directed. 26 S&F in replacement of GI tubing 40mm bore light grade in trenches/floor/fixed along pole for cable/earth strip protection with proper size of MS clamp, nut, bolts and washers complete all as specified and directed. 27 S&F in replacement of single pointed air termination aluminium rod 12mm dia, 300mm long to fix on wall/roof/pipes with suitable MS clamp, nuts, bolts and washers as required at site complete all as specified and directed. (Note: MS/PCC repair work shall deemed to be included in quoted rate. 28 Testing of all type of existing earthings in the station by carrying out the following:- (a) Seperating the earthing strip from the test point by opening the nut bolts or by cutting theearthstrip as required and carrying out earth testing by a calibrated digital earth tester of renowned make ( ISI marked) in presenceof JE E/M /Engr-in- charge & rep of user. (b) A earth testing register shall be opened and values to be noted down with signature of rep of user. (c) In case desired values is not achieved ,measure such as watering the earth pit to be done before carrying out retest of same earthing pit. In the event of not achieving the desired value ,earthing pit will be repaired by digging the earth pit to required level and addingsalt & coal or replacement with new earthingas directed . Note:- (1) Wateringofearthing pit to be attain desired value is using water bowser or by any means included the quoated raated (2) In case desired value is not achieved and earthing is required to be repaired or redone new earthing ,same shall be done as per direction of GE/ Engr-in-charge for which rate will be paid separately under relevant items of schedule. (3) Calibrated &ISI marked Earth tester shall be arranged by contractor &included in quoated rate. (4) Earth testing register to be filled with date & signature of rep of user .Unsigned values noted in the register will not be accepted. (5) Broken Earthing pits /funnels /pipe to be replaced for which rates shall be quoated separately BOQ. (6) An experience & qualified manpower shall only be engaged to carrying out the earth testing. (7) Refixing of earthing strip to the test point /brazing /fixing nut bolt to make good the testing strip will be carrying out & to be included in the quoated rate. (8) If retesting of earthing is required after repairs ,same shall be paid extra. 29 Taking down Oldmaterial retrieved from copper/chemical/ GI earthing any type and size. 30 Supply & fix 15 mm Taps of cast iron or malleable cast iron galvanised,screwed for GI pipe and fixed with 15mm dia bore pipe for filling water to earth pit.complete all as specified and directed by Engr-in-charge. 31 Supply & fix 15mm dia stop valves cast copper alloy screwed down high pressures, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-charge. 32 M&L for pouring of Earth Rechargerwater soluble soil reactivation earthing compound in GEL form per 6 kg bucket comprising of ion and catalyzer for reduction of earth resistance as retaining moisture in the earth pit complete by excavating Earthing pits for pouring of Earth recharger compound gel in Earthing pit by digging 1 feet deep around the earth pit, mixing the earth recharger with 10 litre of water separately and pouring the solution into digged hole slowly slowly within a period of 02 hours,leaving the solution with earth pit for 04 hours and then checking the resistance allas specified and directed by engineer in charge.Make-DSS or equivalent 33 Note :- An amount of Rs. 40,250.00on account of credit schdule for Sch A Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
Contract Date: Jan 30, 2026 Contract Value : 16.00 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu And Kashmir View Result →
20.
Rural Development #11341436 Price Bid
Tender for Supply Of Electrical Material For Gr Anchayat Pirangut,Tal-Mulshi, Dist-Pune , Electrical Material , 6 Sq Mm 2 Core Aluminium Wire , 10 Sq Mm 2 Core Aluminium Wire , 1.5 Sq Mm 3 Core Copper Flexible , 2.5 Sq Mm 3 Core Copper Flexible , 1 Sq Mm 2Core Copper Flexible Cable , 2.5 Sq Mm 2Core Copper Flexible Cable , 10 X 4C Copper Armoured , 16X 4C Copper Armoured , 50 X 4C Alm Arm , 2.5 Sq Mm 2 Core Alumiium Wire , 10 Sq Mm 2 Core Armoured Cable , 6 Sq Mm 2 Core Armoured Cable , 4 Sq Mm Wire , 10 X 4C Aluminium Armoured , 16X 4C Aluminium Armoured , 9 W Bulb , 18 W Bulb , 23 W Bulb , 30 Watt Bulb , 40 W Bulb , 40 W Led Street Light , 50 W Led Street Light , 60 W Led Street Light , 72W Led Street Light , 100W Led Street Light , 120W Led Street Light , 50 W Led Flood Light , 100W Led Flood Light , 120W Led Flood Light , 150 W Led Flood Light , Led Light Fitting Charges On Highmast , Holder , Peddel Holder , 32 A Mcb S , 32 A Mcb D , 16 A Mcb S , 16 A Mcb D , 63 A Mcb S , 63 A Mcb D , Meter Box 12 X12 , Meter Box 18X 24 , Insulation Tape , 33Mm Gi Pipe 2 Ft , 40 Mm Gi Pipe 3 Ft , Single Pole Mcb Box , Double Pole Mcb Box , Auto Timer , Hammer , Screw Driver , Screw Driver Set Star , Tester , Hand Gloves 100 Am , Phase Wire Copper , Cement Pole Clamp , Ms Pole Clamp , Circuit Fuase 100 Am , Circuit Fause 63 Am , Hrc Fause Puller , Single Arm Bracket , Duble Arm Bracket , Three Arm Street Light Bracket , Switch Button , Nut Bolt , Cement Screw , Single Button Board , 2 Button Board , 3 Button Board , 9 Mtr Pole , 11 Mtr Pole , 4 Arm Bracket , 6 Arm Bracket , 6 Mtr Pole , 8 Mtr Pole , 7 Mtr Pole , Foundation Bolt , Gi Tar , Rawal Plug , Dp Switch , Tongtester , Best Quality Wireman Tool Bag , Service Wire Mani , Players , Bed Switch With Touch Button Box , 20 annual periodical maintenance Mcb With Mcb Box , Digital Multimeter , Digital Clamp Meter , Countinuty Tester , Aa Battery & Aaa Battery Cell , 5 Watt Torch , Water Proof Tap Box , Pvc Switch Board 8X10 , Pvc Switch Board 6X10 , Pvc Switch Board 4X7 , Pvc Switch Board 4X4 , 6 annual periodical maintenance Socket , 16 annual periodical maintenance Ss Combaine With Box , 16 annual periodical maintenance Switch , 16 annual periodical maintenance Socket , 32Amp Fuse , 100Amp Fuse , 1 Inch Cesing Patti , 3/4 Inch Cesing Patti , 6 annual periodical maintenance 3 Pin Top , 16 annual periodical maintenance 3 Pin Top , Screw , 8 Mm Copper Fuse Tar , 6 Mm Copper Fuse Tar , Copper 2 Core 1.5 Sqmm , Drill Machine Hammer Type , 2.5 Mm 4 Core Copper Wire , 4 Pole Mcb , All Size Ms Mcb Box , 25Amp 30Amp 3Phase Contactor , 4 Mm 2 Core Aluminium Armoured , 4 Mm 2 Core Copper Armoured , 60 Mm 4 Core Copper Armoured , 500 Mm Dwc Pipe , All Size Aluminium Lugs , Ss All Size Lugs , All Size Cable Joint , All Size Spanner Set , L & Key Set , 16 annual periodical maintenance Power Point , All Size Moduler Plate , Square Box , 8Mm 10 Mm Fasner , Adaptor , Remote Bell , 3 Phase Timer , 6 annual periodical maintenance Switch , 1 Inch Pvc Pipe , 12 Watt Solar Street Light , 15 Watt Solar Street Light , 18 Watt Solar Street Light , Shifting Of Highmast Pole , Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 120 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe , Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 95 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe , 1 Sq 1 Core Mm Copper Wire , 2.5 Sq 1 Core Copper Wire , High Speed Ceiling Fan , 200 Watt Led Flood Light , Sl Pole , Lt Pole , 200 Watt Led Flood Light , Supplying And Erecting Triple Pole Mini Feeder Pillar With 500V, 200A Fpmccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A With Aluminium Bus Bar Erected In 14 Swg Crca Sheet Box With Supporting Angles, Self Locks, Gasket Having Ip54,Ik10 Protection And Slanting Top To Be Erected On Provided Foundation Complete , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½Core 240 Sq. Mm. Luminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe , Sky Lift Crane , Meter Box , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 300 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
21.
Coal and Mines #11337639 AOC
Bids Are invited for Custom Bid For Services - Electrical Works For Maintenance Of Quarters And Manoranjan Kendra Of Urjagram Colony, Wani Area Under Mission Sehat - Point Wiring For Light/Bell/Exhaust Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw (Materia + Labour) , Point Wiring For Independent Plug In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw (Materia + Labour) , Point Wiring For Light/Bell Concealed Type In Min 20 Mm Hms Pvc Conduit With 1.5 Sq.Mm. (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Cw (Materia + Labour) , Point Wiring For Independent Plug, Concealed Type In Min 20 Mm Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wires, Modular Type Switch And Socket, Earthing And Required Accessories As Per Specification No Wgpw/ Sw (Materia + Labour) , Supplying Modular Type Switch 6A/10A On Provided Plate And Box With Wiring Connections Complete. ( Materia Only) , Supplying Modular Type Switch 16A On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type Bell-Push 6A/10A On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type 3 Pin 6A Multi Socketwith Safety Shutter On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type 3 Pin 6/16A Multi Socket With Safety Shutter On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying 6A 3 Pin Plug Top Bakelite Type Of 230V A.C. Supply. (Materia Only) , Supplying 16A 3 Pin Plug Top Bakelite Type Of 230V A.C. Supply. (Materia Only) , Supplying Flush Type Shockproof Plug Socket 6A & 16A (6 Pin) With 16A Switch Combined With Indicator L And Fuse With Gang Box On Wooden Board. (Materia Only) , Supplying Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X6 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Pvc Insulated Pvc Round Sheathed Fr 1.5 Sq.Mm (30 No. X 0.25Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia Only) , Supplying Pvc Insulated Pvc Round Sheathed Fr 2.5 Sq.Mm (50 No. X 0.25Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia Only) , Supplying And Erecting Pvc Insulated Pvc Round Sheathed Fr 4 Sq.Mm (56 No. X 0.30Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia + Labour) , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Wire Armoured (Round) Cable 1100 V, 2 Core 4 Sq Mm Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu (Materia + Labour) , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Wire Armoured (Round) Cable 1100 V, 2 Core 6 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu (Materia + Labour) , Supplying Hms Pvc Conduit 25Mm Dia. With Pvc Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Materia Only) , Supplying Pvc Trunking (Pvc Casing-N-Capping) Of Size 20Mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Materia Only) , Supplying Pvc Trunking (Pvc Casing-N-Capping) Of Size 25Mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Material Only) , Supplying Pvc Box Trunking Of Size 50X50mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Box. (Material Only) , Supplying Gi Flexible Conduit 25Mm Dia. Conforming To I.S. With Required Number Of Couplings, Bushes, Check Nuts Etc. Complete (Material Only) , Supplying Spmcb 6A To 32A, C-Series With Rated Short-Circuit Breaking Capacity(Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Sp Mcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Dp Mcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Fp Mcb 40A To 63A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying 4 Pole Isolator Only Switch Version Of Miniature Circuit Breakers Of 80/100A In Provided Distribution Board. (Material Only) , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 8 Ways (8 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame As Per Specification No. Sw-Mcbdb (Material + Labour) , Supplying & Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 10 Ways (10 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection Provided On Iron/Gi Frame As Per Specification No. Sw-Mcbdb (Material + Labour) , Providing, Erecting And Commissioning 2 Pole Rccb Only Of Electromagnetic Type With 30/100/300 Ma Sensitivity And Having Capacity Of 40A Complete As Per Specification No. Swrccb/ Rccb (Material Only) , Providing & Erecting 3 Pole Mccb, 415V, Up To 100A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb, 415V, 200A, Rated Short-Circuit Breaking Capacity25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magneticsetting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact.Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb 415V, 250A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu) Adjustable Thermal Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb 415V, 630A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Supplying & Erecting On Load Change Over Switch 4 Pole, 415V, 200A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3 As Per Specification No. Sw-Swr/Cos. (Material + Labour) , Supplying, Erecting, Testing & Commisioning Static Energy Meter With 240V 50 Hz. Ac Supply 5 To 30 A, Accuracy Class 1.0 With Backlit Lcd Display, (Measuring And Display Kwh, Kvah,V, I, Pf, Frequency, Kw, Kva, Six Months History Of Energy & Md In Kw & Kva) With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weatherproof Pvc Wires Duly Tested By Electric Supply Company. , Providing Temporary Illumination Consisting Of White/Colour Series Lights With 8Mm Led Miniature L S Of 2 To 3.4V [1000 Nos] With Cap With Required Switchgears Erected And Dismantled With Rotor Effect As Approved With Scaffolding, Up To Three Days As Per Specification No. Te-Il/Srl (Material + Labour) , Supplying And Erecting Quartz Electronic Time Switch Having 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Upto 16A To Use Independently Or In Conjunction With Contactor. (Material + Labour) , Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching On And Switching Off Street Light As Per Daily Sunset And Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230V / 10A With 10 Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacity Contactors Timer Erected In Provided M.S. Box. (Material + Labour) , Supplying And Erecting Four Pole Power Contactor 430V, 40A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. (Material + Labour) , Supplying 12 V/200Ah Tubular Battery With Battery Terminal Wire, Duly Charged Complete With 36 Months Warranty Complete (Material Only) , Supplying, Erecting, Testing & Commisioning Of Required Size Electrolyte Copper Bus Patti Or Bar Tin Plated In Bus Bar Chamber/In Panel Or Any Other Purpose, Suitable For 500 Volt With Require Capacity Having Thermal Conductivity Of 400W Per Meter With Composition Pure Copper 99.9% Current Density 1.8 With Fixing Arrangement (Like Lug Or Bottle Type Lug) To Both The End With High Grade Polyolefin Insulation Sleeve Complete As Per Specification No. Cp-Bb (Material + Labour) , Supplying Ding Dong / Electronic Musical Type Call Bell With Heavy Duty Coil Suitable To Operate On 230V A.C. Supply Erected On Polished Double Wooden Block/Sunmica Block Of Suitable Size (Material Only) , Supplying Electronic Type Cordless Call Bell Erected On T.W. Board Having Portable Bell Push Working On 9V D.C. Battery And (Effective Range Upto 45 Meter) Bell On 250 V A.C. Supply. (Material Only) , Supplying 5W-7W, 230V Integral Type Led L Suitable For B-22/E-27 Base. (Material Only) Fg-Lp , Supplying 10-12W, 230V Integral Type Led L Suitable For B-22/E-27 Base. Fg-Lp , Supplying 18W, 230V Integral Type Led L Suitable For B-22/E-27 Base. Fg-Lp , Supplying & Erecting Integral Post Top Lantern Fixtures (Light House Type) Suitable Upto Led 18 W L Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole/ Bracket As Per Specification No. Fg-Odf/Ptl. (Material + Labour) , Supplying Pvc Surface Modular Double Mounting Plate 3 Modules Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 6 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 8 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 12 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 16/18 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Module Complete.(Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Module Complete Duly Connected. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 16/18 Module Complete. (Material Only) , Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E Class Insulation. (Material + Labour) , Making Trench In Soft Soil Having 0.75M Depth And Minimum 0.3M Width For Laying Provided Cables Up To Voltage Level Of 1.1Kv Complete As Per Specification No. Cw-Exn-Ctr , Supplying 6 To 32A, 10Ka, Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. (Material Only)
Contract Date: Ref. Documents Contract Value : 6.45 Lakh
Boards / Undertakings / PSU No of Bidders 4
Maharashtra View Result →
22.
Defence #11336199 AOC
Bids Are Invited For Supply And Construction Of Pre Engineered Double Story Building Of Size 21 Point 35 M X 6 Point 10 M With 1 Point 5 M Wide Verandah , Ceramic Tiles Of Size 600 Mm X 600 Mm For Floor Thickness Between 9 To 10 Mm Thick , White Cement , Curtain Arrangement Drapery And Rod Made Of 25 Mm Dia And 1600 Mm Long Alongwith Fixing Arrangement Complete , Cement 43 Grade Opc Packed In Hdpe Bag Each 50 Kg Wt , Coarse Sand Free From Vegetation , Coarse Aggregate 20Mm Graded , Coarse Aggregate 40 Mm Graded , Stone Boulder 9 Inch To 12 Inch , Pvc Pipe 75Mm Each 3 Mtr Long , Distribution Box 8 Way Spn Comma 240 Volts Copper Bus Bar And Neutral Link Earthing Stud , Mcb Spn 240 Volts 32 Amps , Mcb Sp 6 To 32 Amps , Pvc Tape 19Mm Wide 5 M Long , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 1 Point 5 Sqmm Single Core , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 4 Sqmm Single Core , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 2 Point 5 Sqmm Single Core , Pvc Casing Capping Of Size 1 Inch Medium Grade Snow White , Pvc Casing Capping Of Size 3 Oblique 4 Inch Medium Grade Snow White , Switch Piano 5 Amp 230 Volts Flush Type One Way Snow White , Led Tube Light Fittings 18 Oblique 20W Rechargeable 230V Box Type 4 Feets , Screw Full Thread 6 X 19Mm 200 Nos Per Pkt , Pvc Switch Board Snow White Size 7 Inch X4 Inch For Sockets And Switches , Pvc Switch Board Snow White Size 8 Inch X 10 Inch For Main Switches Db , Pvc L Bend And T Junction Joint For Pvc Casing And Capping , Switch Socket Combination Snow White Multipurpose 2 In 1 Comma 15 Amp 230 Volts , Switch Socket Combination Snow White 5 Amp 230 Volts , Service Bracket 40Mm Dia Gi Tubing Medium Grade 1 Point 5 Mtr Long , Service Cable Pvc Insulated Aluminium Conductor Heavy Duty 10 Sqmm 2 Core , Ceiling Rose Three Terminal Snow White , Led Bulk Head Fitting With Led Lamp 10 Watts , Pvc Flexible Wire Copper Conductor Multi Stranded 0 Point 0016 Oblique 76 , Pvc Flexible Conduit Pipe 15 Mm Dia , Pvc Round Oblique Square Block , Fire Extinguisher Of One Kilogram Capacity Dry Power Type Along With Its Accessories , Change Over Switch 32 Amp 4 Pole , Earthing Plate 600 X 600 X 6 Mm Galvanised Steel Suitable For Gi Strip Fittings , Ci Earth Pit Cover Of Size 300 X 300 X 6 Mm With Angle Iron Of Size 20X20Mm , Funnel Fitted With 20 Mm Diameter Gi Pipe 1 Point 5 M Long Pipe , Gi Wire 4 Mm Diameter For Earthing , Charcoal , Salt Normal , Air Termination Single Pointed Aluminium Rod 12 Mm Dia And 300 Mm Long , Testing Point Terminal Block Make Of Gun Metal And Phosphorus Bronze Size 75 X 75 X 25 Mm Drilled , Aluminium Strips 25 X 3 Point 0 Mm , Galvanized Iron Strip 32 X 6 Mm , Insulating Pvc Block 75X75X30 Mm With Insulating Clamp Nut And Bolt , Individual Standalone Plastic Body Smoke Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Individual Standalone Plastic Body Heat Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Fire Ball Extinguisher Of 2 Kg Wt With Suitable Provision For Wall Mounting , Double Sleeping Bunk Alongwith Rexene Sleeved Mattress , Steel Bed Side Locker Of Size 1000Mmx1520Mmx450Mm , Study Chair Of Size Length 56 Cm Comma Height 82 Cm And Width 56 Cm , Study Table Of Size 4 X 2 Wooden Top Round Tube Structure With Three Drawers , Looking Mirror Of Selected Quality Frameless Of Size 600X450X5Mm , Water Dispenser Of 230 V 500 Watts Without Refrigerator With Normal Cold And Heating Capacity Of 5 Ltrs , Portable Indoor Type High Quality Kero Heater Metal Body With Capacity 4 Ltr , Plastic Dustbin Of Capacity 40 Ltr Total Quantity : 3925
Contract Date: Ref. Documents Contract Value : 1.21 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
23.
Housing Urban and Rular Development #11333527 Technical Bid
Tender For Rate Contract For Tentage Work Like Safe House, Dome, Stage Etc. Construction Including Barricating And Miscellaneous Works And Electric Work While Vip Visits Under Pwd Division Dungarpur Distt Dungarpur= 1 Hire Charges Includes Transporatation At Site Within Division Boundary, Loading, Unloading, Placing And Removing Complete. For Any Place With In Division Boundary. Hire Charges For 3 Days.Chairs : Pvc Chair 2 Plastic Cane Chair Of Aluminium Pipe With Arms. Steel Pipe Pedded Chair 3 Tables :Tables : Wooden Table 6 X 3 (Babool). 4 Tables : Centre Table Glass Top 2X4 5 Floor Covering :Cotton Durry (Old). 6 Cotton Durry (New). 7 Non Woven Synthtic Carpet (Red/Green) (New) 8 Woolen Carpet (New). 9 White Cotton Chader (Sheet) (Washed) 10 Pipe Pandal With Covering Ht From To 12 To 18 Ft 11 Curtain Cloth (View Cutter ) Made Out Of Steel Pipe Frame Covering With Good Quality White Cloth To Cut View Including Making Holes And Made Necessary Strengthening Support Against Wind Pressure Complete . 12 Kanat Fixed With Tent. (15X6) 13 Kanat Fixed Without Tent. (15X6) 14 5Mm Galvanised Iron (G.I) Pipe 6 Mtr. Long With New Silk Flag. 15 Water Proof Tripal. 16 Wooden Stage Height 60Cm.With Steps Complete 17 Wooden Stage Height 120 To 180 Cm.With Steps Made Of 50 Mm Dia Iron Pipe Frame With Adjustable Height System And Having Smooth Top Wooden Board Complete . 18 Cotton Mattress With White Sheet (Chader). 19 Dunlop Mattress With White Chadar Size 6X3. 20 Massand With White Cover. 21 Speech Stand Having Sunmica Top. 22 White Cotton Cloth Cover For Padded Chair Inculding Ribbon 23 Barricading With Sal Ballies As Per Design Including Tying With Vertical Post By Coconut Strings Including Digging Out Holes In All Types Of Soil Complete In All Respect With Two Horizontal Members Height 1.2 M Upto 1.5M Above Ground Level And Vertical Supports Upto 2.5 Centre And Upto 3 Days Period Including Removal And Cleaning The Site Complete In All Respect & Including Dressing Of Sides And Providing Retro Reflective Tapes For Traffic Safety As Per Direction Of Engineer-In Charge In All Types Of Soil. 24 Barricading With M.S. Pipe As Per Design Including Tying With Vertical Post Including Digging Out Holes In All Types Of Soil Complete In All Respect With Two Horizontal Members Height 1.2 M Upto 1.5M Above Ground Level And Vertical Supports Upto 2.5 Centre And Upto 3 Days Period Including Removal And Cleaning The Site Complete In All Respect & Including Dressing Of Sides And Providing Retro Reflective Tapes For Traffic Safety As Per Direction Of Engineer-In Charge In All Types Of Soil. 25 Making Of Holes In Cement Concrete/ Bitumenous Road By Power Driven Hammer For Barricating Work As Per Direction Of Engineer In Charge 26 Hire Charges For Folded Type Two Seater Sofa Set (Cum Bed) With Good Quality White Cloth Cover 27 Vip Chair With Cushion 28 Add Extra For Hire Charge For Providing Welded Mesh Size 25X25 Mm (16Swg) Over Barricating (Excluding Hire Charge Of Barricating) 29 Water Proof Tent With Pipe Pandal Supported With Bamboo/Balli /Ms Pipe Frame. 30 Water Proofing Canopy With Ornamental Frill, Inner Ceiling & Curtains Above Size 20X20 31 Three Seater 32 Chemical Toilet With House Keeping Arrangement And Providing Liquid Soap, Tissues, Comb, Freshener Etc. 33 Water Proof Dome With Truss Steel Strcture, Inner Ceiling & Curtains 90 Span 34 Aluminium German Hanger Tent Roof Made Up Of Waterproof, Fire Resistant Synthetic Rubber Fabric Of 885 Gsm. 35 Hire Charges For Led Flood Light Luminaire ( White Or Warm White As Required )For 90- 150 Watt With The Standard Housing ,Pole & Mounting Accessories With Wiring, Connection With Skilled Operator To Operate System Etc. As And When Required. With Suitable Pole For 1St Day 36 For 2Nd / 3Rd Day 37 Without Suitable Polefor 1St Day 38 For 2Nd / 3Rd Day 39 Hire Charges For Led Screen Day Light Type (P3.9) Of Suitable Size For Display Complete With Mounting Arrangement/Scaffolding, Masking Of Mounting Stand, Signal Booster, Network Switch /Splitter, Data And Power Cables And Sound System Arrangement Etc. With Skilled Operator To Operate System Etc. As And When Required. For 1St Day 40 For 2Nd / 3Rd Day 41 Hire Charges For Hd Video Camera Suitable For Sdi/Hdmi Output, Recording In Dvd/Hard Disk Fuction Complete With Two Operator As And When Etc As Required. For 1St Day 42 For 2Nd / 3Rd Day 43 Hire Charges For Video Projection Arrangement (Excluding Screens) With 3 Nos. Video Camera (Pwm 120 Sony Nx 5Z7/Equivalent) Including Mixer (Pansonix Mx70/Data Video Mx500/ Equivalent) Complete With Required Hdmi/Sdi Etc. Wiring Vtr, Switchers, With Skilled Operator To Operate System Etc As And When Required. For 1St Day 44 For 2Nd / 3Rd Day 45 Hire Charges Of Crane With Operators For Video Camera For 360° Movement Complete Arrangement With Skilled Operator To Operate System As And When Etc As Required. For 1St Day 46 For 2Nd / 3Rd Day 47 Hire Charges For 42\ Hd Led/Plazma Tv Complete With Mounting Arrangement , Connections, Testing Etc. With Skilled Operator To Operate System Etc As And When Required. For 1St Day 48 For 2Nd / 3Rd Day 49 Hire Charges For 50/52\/Higher Sizes Hd Led/Plazma Tv Complete With Mounting Arrangement , Connections, Testing Etc.With Skilled Operator To Operate System Etc As And When Required. For 1St Day 50 For 2Nd / 3Rd Day 51 Hire Charges For Equipments Required For Public Address & Sound System For A Very Important Public Function/ Vvip Visits Including Transportation,T&P,Scafolding, Testing And Connections With Trial Etc. With Skilled Operator To Operate System Etc As And When Required. 15 Inch 3 Way Line Array Speaker Adamson E15/L Acoustics -K1/D&B Gsl Or Equivalent Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 52 For 2Nd / 3Rd Day 53 12 Inch 3 Way Line Array Speaker Adamson E12/L Acoustics -K2/D&B Gsl/Jbl A-12 Or Equivalent Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 54 For 2Nd / 3Rd Day 55 Pentium -Iv Laptop With Hdmi Cable & Stereo Sound Output Make-Hp/Dell/Lenovo Or Equivalent As Approved By Engineer In Charge.For 1St Day 56 For 2Nd / 3Rd Day 57 Cross Overs For The Speakers Distributions Make- Dbx Or Equivalent As Approved By Engineer In Charge.For 1St Day 58 For 2Nd / 3Rd Day 59 Amplifier Suitable For The Installed Speakers/Sound System As Required.For 1St Day 60 For 2Nd / 3Rd Day 61 Suspension Kits With Suitable Stand For The 3-Way Speakers As Required.For 1St Day 62 For 2Nd / 3Rd Day 63 Required Necessary Snake Cables,Audio Connection Cables, Speakers Cables,Electrical Wiring, Boards, Connector Etc For Speakers/Horns Etc. As Required For 1St Day 64 For 2Nd / 3Rd Day 65 Top Speakers Jbl/Rcf Or Equivalent. As Approved By Engineer In Charge.For 1St Day 66 For 2Nd / 3Rd Day 67 Monitor Speakers Jbl/Rcf Or Equivalent. (For Stage) As Approved By Engineer In Charge.For 1St Day 68 For 2Nd / 3Rd Day 69 Cordless Mike Hi -End(For Vvip Visit)With Antenna Combiner Etc.Make:-Shure .Ad4D/Sennheiser 6000 Or Equivalent.Reputed Make/Model As Approved By Engineer In Charge..For 1St Day 70 For 2Nd / 3Rd Day 71 Digital Mixer (128+48) Digico Sd10/Avid S6L 24C/Dlive 7000 Or Equivalent..Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 72 For 2Nd / 3Rd Day 73 Channel Mixer Digital (32+16) Midas M32/Sq7/ Sound Craft S1 Or Equivalent.Reputed Make/Model As Approved By Engineer In Charge.For 1St Day 74 For 2Nd / 3Rd Day 75 Effect Processors. Make:-Lss/Behringer Or Equivalent As Approved By Engineer In Charge.For 1St Day 76 For 2Nd / 3Rd Day 77 Compressors. Make:-Lss/Behringer Or Equivalent As Approved By Engineer In Charge.For 1St Day 78 For 2Nd / 3Rd Day 79 Amplifiers 700 Watt Rms At 100 Ohm.For Horns Make:-Ahuja/Qsc Or Equivalent As Approved By Engineer In Charge.For 1St Day 80 For 2Nd / 3Rd Day 81 Mikes With Big Stand. Make:-Shure/Akg/Sennheiser Or Equivalent As Approved By Engineer In Charge.For 1St Day 82 For 2Nd / 3Rd Day 83 32 Band Equalizer. Make:-Lss/Behringer Or Equivalent As Approved By Engineer In Charge.For 1St Day 84 For 2Nd / 3Rd Day 85 Snake Cable/Audio Cable/ Bnc Cable /Cat 6 Cable (100 Mtr) Including Accessories, Connection, Testing Etc. As Required.For 2Nd / 3Rd Day 86 For 2Nd / 3Rd Day 87 Hire Charges For Light Point Complete With Lamp,Holder,Wiring In Casing Or In Pvc Conduit , Controlling Switch And Circuit Protection McbS With Skilled Operator To Operate System As And When Etc As Required. For Shops/ Stalls Etc. For 1St Day 88 For 2Nd / 3Rd Day 89 Hire Charges For Power/Light Plug On Board Including Wiring In Pvc Casing Or In Pvc Conduit , Controlling Switch And Circuit Protection McbS With Skilled Operator To Operate System As And When Etc As Required. For Shops/ Stalls Etc. For 1St Day 90 For 2Nd / 3Rd Day 91 Hire Charges For Led Tube Light Fixture With 18/20 Watt With Skilled Operator To Operate System As And When Etc As Required.For 1St Day 92 For 2Nd / 3Rd Day 93 Hire Charges For Silent Type D.G. Set, Including Change Over Switch. Control Panel, 2 No. Pipe Earthing Etc. And Excluding Pol With Skilled Operator To Operate System As And When Etc As Required. Of Following Capacity:62.5 Kva 94 From 2Nd Day Onwards 95 125 Kvafor 1St Day 96 From 2Nd Day Onwards 97 Hire Charges Of Main Service Line For 3 Phase Connection Upto 50 Mtr. Length (Without Any Joint) Including Meter Board, Panel/Distribution Board And Supports With Skilled Operator To Operate System As And When Etc As Required. Upto 25.0 Sq.Mm Size Pvc Insulated And Sheathed Cable( Aluminium Armoured Or Un-Armoured As Required.) For 1St Week 98 For 2Nd / 3Rd Day 99 Above 25.0 Sq.Mm & Upto 95 Sq.Mm Pvc Insulated And Sheathed Cable Aluminium Armoured Or Un-Armoured As Required.)For 1St Week 100 For 2Nd / 3Rd Day 101 Above95.0 Sq.Mm Pvc Insulated And Sheathed Cable Aluminium Armoured Or Un-Armoured As Required.)For 1St Week 102 For 2Nd / 3Rd Day 103 Supply And Filling Of Pol For Dg Sets 104 Hire Charges Of Sub Service Line For Single/ Three Phase Connection Upto 30 Mtr. Length Including Dist. Board And Supports With Skilled Operator To Operate System As And When Etc As Required. Single Phase Upto 6 Sqmm Pvc Insulated And Sheathed Aluminium Cablefor 1St Week 105 For 2Nd / 3Rd Day 106 Three Phase & Neutral Upto 10 Sqmmpvc Insulated And Sheathed Aluminium Cablefor 1St Week 107 For 2Nd / 3Rd Day 108 Hire Charges For Jumbo Polycarbonate/Fiber Body Moveable Desert Cooler Complete With Water Filling And Operator With Skilled Operator To Operate System As And When Etc As Required. For 1St Day 109 For 2Nd / 3Rd Day 110 Hire Charges For Following Type Of Airconditioners Including Copper Piping , Drain Piping And Electrical Connections With Skilled Operator To Operate System As And When Etc As Required. 3.0 /4.0 Tr Tower Type Split Acfor 1St Day 111 2Nd Day Onwards 112 Hire Charges Of 1 Kva Online Ups With Battery (Backup Of 1 Hour At Full Load) With Wiring,Connection With Skilled Operator To Operate System As And When Required.. For 1St Day 113 For 2Nd / 3Rd Day 114 Hire Charges Of Public Address System For A Important Public Function With 5/ 6 No. Of Microphones With Following Nos Of Stand Hi Fi Box, Speakers/ Horns, Stand By Amplifiers , Battery Backup Complete Including Transportation Etc. With Skilled Operator To Operate System As And When Etc As Required. : 4 Nos 3 Way Big Box Speakers And Upto 20 Horn(5000 Audiences)For 1St Day 115 For 2Nd / 3Rd Day 116 Pipe Earthing As Per Is:3043- 1987 With 3.0 Mtr. Long, 40 Mm Dia. B Class G.I. Pipe Is: 1239 (Part-1) 2004, Equivalent To Bs : 1387 With Perforated Holes Of 12 Mm Dia ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, Heavy Duty Weather Proof Poly-Propylene Earth Inspection Chamber As Per Requirement Of Is/Iec 62305 And Tested As Per Iec 62561-5 With Lockable Jam Free Lid Suitable For Safe Working Load 60 Kn Of Round / Square Size 250 Mm, And Height 250 To 300 Mm And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required. 117 Hire Charges For Following Type Of Airconditioners Including Copper Piping , Drain Piping And Electrical Connections With Skilled Operator To Operate System As And When Etc As Required. 8.5 Tr Ductable Type Split Acfor 1St Day
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
24.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
25.
Heavy Industries and Public Enterprises #11319585 AOC
Tender For Electrical Works Required For Installation And Operation Of Radial Forging Plant Inside Msf, Ishapore.; 1 HV VCB PANEL - 1 (M & L): 5-Panel HT Switchboardto be connected with Cu busbars to the existing JYOTI make HT Panel at MRS-2 (3-nos.) & Pry-1 substation (2-nos.), Comprising of the followings: (Detailed specification is in ANNEXURE-1)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 1200 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: JYOTI, SIEMENS. 2 HV VCB PANEL - 2 (M & L): 2-Panel HT Switchboardto be connected with Cu busbars to the existing SIEMENS make HT Panel at MRS-1, Comprising of the followings: (Detailed specification is in ANNEXURE-2)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 1200 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: SIEMENS. 3 HV VCB PANEL - 3 (M & L): 6-Panel HT Switchboardto be connected with Cu busbars to the existing ALSTOM/SCHNEIDER make HT Panel at RF-1 substation, Comprising of the followings: (Detailed specification is in ANNEXURE-3)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 800 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: SCHNEIDER. 4 HT CABLE (M & L): Supply & laying of XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric power cable with aluminium conductor, 11000 volts grade, cross sectional area 300 sq.mm., 3 corefor (1) MRSto RF-1 S/S(two runs), (2) Tie link between MRS1 & MRS2, (3) Supply to T1 & T2, complete in all respect. Make: HAVELLS / GLOSTER / CRYSTAL / KEI. 5 HT CABLE TERMINATION (M & L): Supply & making of cable termination with termination-kit for 11 KV(E) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sq.mm. Make: RAYCHEM, DENSON, 3M. 6 HT CABLE ST. TH. JOINT (M & L): Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm. Make: RAYCHEM, DENSON, 3M. 7 TRANSFORMER 2500 KVA (M & L): Supply and installation of Transformer, step-down, 11-6.6/0.433 KV complete, outdoor type, copper wound, resin cast dry type of capacity 2500 KVA complete in all respect. (Detailed specification is in ANNEXURE-4. Drawing to be approved before manufacturing). Make: SCHNIEDER / VOLTAMP / RAYCHEM / ABB. 8 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). INCOMER & BUSLINK ACB 4000 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Incomer - 02 nos. & Buslink - 01 no. Make: SIEMENS / L&T / SCHNEIDER. 9 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING ACB 1600 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 10 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING ACB 1000 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 11 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING MCCB 400 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 400 Amp. Adjustable type (300 - 400Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 12 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING MCCB 250 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 400 Amp. Adjustable type (200 - 2500Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 13 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). INCOMING MCCB 800 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 800 Amp. Adjustable type (600 - 800Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 14 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). OUTGOING MCCB 250 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 250 Amp. Adjustable type (200 - 250Amps), Thermal Release with breaking capacity 36 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 15 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). OUTGOING MCCB 160 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 160 Amp. Adjustable type (100 - 160Amps), Thermal Release with breaking capacity 36 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 16 LT CABLE 300 SQ.MM.(M & L): Supply& laying of PVC/XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 300sq.mm., 3.5core, confirming to IS:7098, complete in all respect. Make: CRYSTAL, GLOSTER, FINOLEX, POLYCAB, UNIVERSAL, HAVELLS. 17 JOINTING / TERMINATION OF LT CABLE 240 TO 300 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 240 to 300 sq mm., complete in all respect. 18 LT CABLE 185 SQ.MM.(M & L): Supply& laying of PVC/XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 185sq.mm., 3.5core, confirming to IS:7098, complete in all respect. Make: CRYSTAL, GLOSTER, FINOLEX, POLYCAB, UNIVERSAL, HAVELLS. 19 JOINTING / TERMINATION OF LT CABLE 120 TO 185 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 120 to 185 sq mm., complete in all respect. 20 AIR CIRCUIT BREAKER 3200A (M & L): ACB 3200 Amps, 4 Pole, 415 V, Manual Drawout type to be Retrofitted in the existing LT Panel (HT shop) with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 21 AIR CIRCUIT BREAKER 1000A (M & L): ACB 1000 Amps, 4 Pole, 415 V, Manual Drawout type to be Retrofitted in the existing LT Panel (HT shop) with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 22 DISMANTLING & REFIXING OF LT AIR-BREAK (SWITCH) DB (L): Dismantling & refixing of LT AIR-BREAK (SWITCH) DB with accessories on MS angle with nuts, bolts etc. 23 EXCAVATION SOIL: Excavation of hard/dense soil over areas, n exc 1.5 m deep in cable trenches and getting out. 24 REFILLING OF SOIL: Returning, filling in, inc spreading, levelling, watering and well ramming of excavated soil for cable trenches. 25 SAND FILLING (M & L): Sand filling under cable trenches over laid cables. 26 GI CABLE TREY AND SUPPORTING COLUMN (M & L): Supply, fixing & febrication of rolled GI channel, angle, sheet, plates, rods and flats of different sizes for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. with Fe-410-W (Gde E-250) quality-B for fixing of prefebricated cable trays / supporting column of different sizes, supports etc., complete in all respect. The structure shall be hot dip galvanized with minimum thickness of coating not less than 80 microns. Galvanization shall conform to IS-2629, 4759 & 4736 as applicable. 27 REINFORCED CEMENT CONCRETE (M & L): Reinforced cement concrete (nominal mix)in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass cement concrete ofType B0 1:2:4 Type B1 1:2:4 (12.5mm graded (20 mm graded aggregate)concrete, complete in all respect. 28 FORMWORK TO CONCRETE (M & L): Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete in all respect. 29 TMT BAR STEEL REINFORCEMENT FOR CONCRETE (M & L): Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)6mm to 8mm dia or securing with clips, complete in all respect. 30 STEEL PIPE (M & L): Galvanised Steel Tubing (Piping), medium grade of bore size 100mm, including all fixing & fitting (MS clamps, flats) laid across drains, roads, fixing complete with all respect. Make: TATA, JINDAL. 31 DEMOLITION OF BRICKWORK & MASONRY (L): Demolition of Brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillers, etc. 32 CEMENT CONCRETING: Cement concrete in foundation, filling and mass concrete Type B2 1:2:4 (40mm graded aggregate), for repairing the demolished brick or masonery work on roads, hard standings & footpaths including tile-soaling, complete in all respect. 33 BRICK FOR CABLE SUPPORT (M&L): Supply & laying of Continuous brick edging; with width equal to the depth of the brick, laid dry, on edge With burnt clay bricks of sub class B, old size on two sides of laid cable. 34 BRICK WORK(M & L): Supply & making of Brick work with subclass B bricksbuilt in cement mortar 1:4 for making of walls & cable trench, complete in all respect. 35 CEMENT PLASTERING(M & L): Supply & making of Cement plastering 10mm thick on fair surfaces of brickwork or concrete surface, in cement mortar 1:4 (with net finish on floor), complete in all respect. 36 EARTH CONTINUITY CONDUCTOR (L): Supply & Fixinging of Earth ontinuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6mm galvanised iron strip. 37 EARTHING (M & L): Supply & making of Earthing for SS LT Switchgear, complete with galvanised steel earth plate electrode, 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge not less than 1.5 meter below ground level, connected with galvanised iron 32 x 6mm strip as earthing lead (upto 7.5m) by means of bolts, nuts, check nuts & washers of GI or GS all as shown in Plate No. 5 to the earthing test point all as specified and indicated including testing on completion. This includes making of pit, providing CI cover, funnel with watering pipe, wire mesh and GI earth lead protection pipe. 38 MS CHEQUERE PLATE: Supply & fixing of Rolled mild steel Plates (Chequered of 8 mm. thickness) [Fe 410-W (Gde-E- 250) quality-A] channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with 2-coat of red oxide primer for cable trench cover. 39 GI CHANNEL/ANGLE/FLAT (M&L): Supply, fixing & febrication of rolled GI channel, angle and flat, [Fe 410-W (Gde-E- 250) quality-A] fixed independently for fixing of LT PDB`s and making & fixing of cable trays / cable cover supports of different sizes, supports etc., complete in all respect. 40 UG CABLE 25 SQMM (M&L): XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm, 3½ core, complete in all respect. 41 JOINTING / TERMINATION OF LT CABLE 16 TO 35 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 16 to 35 sq mm., complete in all respect. 42 SUBMAIN WIRING (M&L): Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in existing surface/recessed as required of size 2x2.5 sq. mm + 1x1.5 sq. mm earth wire in steel conduit, junction box, complete in all respect. Make: MESCAB, HAVELLS, POLICAB, KEI, FINOLEX, ANCHOR. 43 160A MCCB WITH ENCLOSURE(M&L): Complete with the following in all respect. MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA to be fixed in the sheet GI steel enclosure. 44 160A MCCB WITH ENCLOSURE(M&L): Complete with the following in all respect. Sheet GI steel enclosure of size 2nos.x 0.5m x 0.5m x 0.3m, and spreader terminal, complete in all respect. Thickness of sheet in1.60 mm. 45 STEEL METAL ENCLOSURE FOR MCB DB (M&L): Supply, fixing & connection of Sheet metal enclosure for DB`s MCB to be used, Three pole and neutral, 4-way, 415 V, double door, complete in all respect. Make: SIEMENS / L&T / SCHNEIDER. 46 MINIATURE CIRCUIT BREAKER 5 TO 32A SP (M & L): Supply and fixing 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissionin, complete in all respect. Make: SIEMENS / L&T / SCHNEIDER. 47 POINT WIRING (M&L): Poing Wiring with copper conductor cables FRLS in stove enamelled Steel Conduit steel conduit for One light point or one fan point controlled by one switch with 2.5 sq. mm size PVC single core cables including earth wire, junction box, complete in all respect. Make: MESCAB, HAVELLS, POLICAB, KEI, FINOLEX, ANCHOR. 48 OH HIGH BAY LIGHT FITTING, 150W(M & L):Supply and fixing LED Overhead High Bay light fitting 1x150 Watt, IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED Overhead High Bay light fixtures driver, holders, connector etc. Complete with all accessories prewired and including fixing on overhead cross beam, connecting up with three core flexible copper conductor cable with suitable size, complete in all respect. MAKE: HAVELLS / PHILIPS / SURYA 49 SECURITY LIGHT FITTING, 90W(M & L):Supply and fixing LED Street light fitting 1x90 Watt, IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED Street light fixtures driver, holders, connector etc. Complete with all accessories prewired and including fixing on overhead column with GI bracket, connecting up with three core flexible copper conductor cable with suitable size, complete in all respect. MAKE: HAVELLS / PHILIPS / SURYA 50 AIR CIRCULATOR(M & L):Supply and fixing IndustrialHeavy Duty pedestal Air Circulator Fan, 30 (750 mm sweep, 415 VAC, 50 Hz, 1440 rpm, delivery-1700 CFM, 28900 m3/hr CI base, MS pipe, MS wire guard, Al. alloy casting, 4 wing blade motor with chord & MCB with enclosure, complete with paint.MAKE: POWER VENT/BAJAJ/CG/CALCUTTA FAN/ALMONARD 51 LOCK, 65MM (M & L):Brass 4 Lever Padlock of size 65mm for steel doors & rolling shutters. 52 SUBSTATION SCADA FOR HT & LT POWER DISTRIBUTION (M & L):Design, engineering, supply, installation and commissioningof MSF SCADA Systems for HT & LT power distribution as per enclosed ANNEXURE-7. complete in all respect.
Contract Date: Jun 26, 2026 Contract Value : 6.13 Crore
Government Departments No of Bidders 4
West Bengal View Result →
26.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
27.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
28.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
29.
Defence #11297024 AOC
Bids Are Invited For Dsls Living Pir Shelter Size 21 Point 35M X 6 Point 1M X 1 Point 5M Enclosed Verandah Front , Cement 43 Grade Opc Packed In Hdpe Bag Each 50 Kg Wt , Coarse Sand Free From Vegetation , Coarse Aggregate 20Mm Graded , Coarse Aggregate 40 Mm Graded , Coarse Aggregate 40 To 63Mm Graded , Stone For Rr Masonary Less Than 6 Inch , Water Proofing Compound , Mild Steel Bars Of Size 6 To 8Mm Dia , Mild Steel Bars Of Size 10 Mm And Above Dia , Oil Bound Distemper , Cement Based Paint Snowcem , Ceramic Tiles Of Size 600 Mm X 600 Mm For Floor Thickness Between 9 To 10 Mm Thick , Ms Binding Wire , White Cement , Wooden Planks For Shuttering Iind Class Wood Of Size 3 Point 0 X 0 Point 30 X 0 Point 026 , Peg Set Of Six Fitted With Galvanised Screws , Curtain Arrangement Drapery And Rod Made Of 25 Mm Dia And 1600 Mm Long , Stone Boulder 9 Inch To 12 Inch , Pvc Pipes 75Mm Each 3 Mtr Long , Distribution Box 8 Way Spn Comma 240 Volts Copper Bus Bar And Neutral Link Earthing Stud , Distribution Box 4 Way Spn Comma 440 Volts Copper Bus Bar And Neutral Link Earthing Stud , Mcb Tpn 440 Volts 40 Amps , Mcb Spn 240 Volts 32Amps , Mcb 6 To 32 Amps , Pvc Tape 19Mm Wide 5 M Long , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 1 Point 5 Sqmm Single Core , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 4 Sqmm Single Core , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 2 Point 5 Sqmm Single Core , Pvc Casing Capping Of Size 1 Inch Medium Grade Snow White , Pvc Casing Capping Of Size 3 Oblique 4 Inch Medium Grade Snow White , Switch Piano 5 Amp 230 Volts Flush Type One Way Snow White , Led Tube Light Fittings 18 Oblique 20W Rechargeable 230V Box Type 4 Feets , Screw Full Thread 6 X 19Mm 200 Nos Per Pkt , Pvc Switch Board Snow White Size 7 Inch X 4 Inch For Sockets And Switches , Pvc Switch Board Snow White Size 8 Inch X 10 Inch For Main Switches Db , Pvc L Bend And T Junction Joint For Pvc Casing And Capping , Switch Socket Combination Snow White Multipurpose 2 In 1 Comma 15 Amp 230 Volts , Switch Socket Combination Snow White 5 Amp 230 Volts , Service Bracket 40Mm Dia Gi Tubing Medium Grade 1 Point 5 Mtr Long , Service Cable Pvc Insulated Aluminium Conductor Heavy Duty 25 Sqmm 4 Core , Ceiling Rose Three Terminal Snow White , Led Bulk Head Fitting With Led Lamp 10 Watts , Pvc Flexible Wire Copper Conductor Multi Stranded 0 Point 0016 Oblique 76 , Pvc Flexible Conduit Pipe 15 Mm Dia , Pvc Round Oblique Square Block , Fire Extinguisher Of One Kilogram Capacity Dry Power Type Along With Its Accessories , Change Over Switch 32 Amp 4 Pole Tpn , Earthing Plate 600 X 600 X 6 Mm Galvanised Steel Suitable For Gi Strip Fittings , Ci Earth Pit Cover Of Size 300 X 300 X 6 Mm With Angle Iron Of Size 20X20Mm , Funnel Fitted With 20 Mm Diameter Gi Pipe 1 Point 5 M Long Pipe , Gi Wire 4 Mm Diameter For Earthing , Charcoal , Salt Normal , Air Termination Single Pointed Aluminium Rod 12 Mm Dia And 300 Mm Long , Testing Point Terminal Block Make Of Gun Metal And Phosphorus Bronze Size 75 X 75 X 25 Mm Drilled , Aluminium Strips 25 X 3 Point 0 Mm , Galvanized Iron Strip 32 X 6 Mm , Insulating Pvc Block 75X75X30 Mm With Insulating Clamp Nut And Bolt , Individual Standalone Plastic Body Smoke Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Individual Standalone Plastic Body Heat Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Fire Ball Extinguisher Of 1 Point 3 Kg Wt With Suitable Provision For Wall Mounting , Double Sleeping Bunk Alongwith Rexene Sleeved Mattress , Steel Bed Side Locker Of Size 1000Mm X 1520Mm X 450Mm , Study Chair Of Size Length 56 Cm Comma Height 82 Cm And Width 56 Cm , Study Table Of Size 4 X 2 Wooden Top Round Tube Structure With Three Drawers , Looking Mirror Of Selected Quality Frameless Of Size 600 X 450 X 5Mm , Water Dispenser Of 230 V 500 Watts Without Refrigerator With Normal Cold And Heating Capacity Of 5 Ltrs , Portable Indoor Type High Quality Kero Heater Metal Body With Capacity 4 Ltr , Plastic Dustbin Of Capacity 40 Ltr , Kassi With Handle , Black Steel Sr Shovel Spade Belcha , Plaster Trowel With Wooden Handle , Showel Square Nose 14 Gauge Blade Size 310 X 245 Mm , Plumb Bob Iron , Crow Bar 1 Point 5 Inch Dia 4 Feet Long , Hammer 1 Kg With Wooden Handle , Hammer 0 Point 5 Kg With Wooden Handle , Brick Line 30 Mtr Nylon Dhaga , Traveler Brick Mason 4 Inch 305Mm , Sprit Level , Measuring Tape 30 Mtr Steel , Water Bucket Steel 13 Inch Dia , Picks Axes With Chisel And Point Ends Kudali 14 Cp Nominal Weight 3 Point 0 Kg , Lime Brush Best Quality , Painting Brush 100Mm Best Quality , Hacksaw Frame Large With Blade 05 Nos , Galvanised Iron Pan Mortar Tasla Comma 18 Gauge Comma 20 Inch Dia , Wooden Waterproof Plywood Comma Thickness 12 Mm , Nails Various Sizes , Rammer Earth With Handle , Tester For Electrician With Plastic Handle 150Mm , Electric Drill Machine Heavy Duty 500 W Electric Backup With Battery And Charger , Drill Bits Hss 5Mm Comma 8Mm And 10Mm For Electric Drill Machine , Electric Tile Cutting Machine With Interchangable Blades 20 Nos , Electric Sheet Cutter Machine With Blade 20 Nos , Puf Rivet Machine , Centre Punch 8Mm , Plumbing Tool Kit , Water Level Pipe 30 Mtr Total Quantity : 9012
Contract Date: Ref. Documents Contract Value : 56.63 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
30.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
31.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
33.
Defence #11288269 AOC
Bids Are Invited For Dsls Living Pir Shelter Size 21 Point 35M X 6 Point 1M X 1 Point 5M Enclosed Verandah Front , Cement 43 Grade Opc Packed In Hdpe Bag Each 50 Kg Wt , Coarse Sand Free From Vegetation , Coarse Aggregate 20Mm Graded , Coarse Aggregate 40 Mm Graded , Coarse Aggregate 40 To 63Mm Graded , Stone For Rr Masonary Less Than 6 Inch , Water Proofing Compound , Mild Steel Bars Of Size 6 To 8Mm Dia , Mild Steel Bars Of Size 10 Mm And Above Dia , Oil Bound Distemper , Cement Based Paint Snowcem , Ceramic Tiles Of Size 600 Mm X 600 Mm For Floor Thickness Between 9 To 10 Mm Thick , Ms Binding Wire , White Cement , Wooden Planks For Shuttering Iind Class Wood Of Size 3 Point 0 X 0 Point 30 X 0 Point 026 , Peg Set Of Six Fitted With Galvanised Screws , Curtain Arrangement Drapery And Rod Made Of 25 Mm Dia And 1600 Mm Long , Stone Boulder 9 Inch To 12 Inch , Pvc Pipes 75Mm Each 3 Mtr Long , Distribution Box 8 Way Spn Comma 240 Volts Copper Bus Bar And Neutral Link Earthing Stud , Distribution Box 4 Way Spn Comma 440 Volts Copper Bus Bar And Neutral Link Earthing Stud , Mcb Tpn 440 Volts 40 Amps , Mcb Spn 240 Volts 32Amps , Mcb 6 To 32 Amps , Pvc Tape 19Mm Wide 5 M Long , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 1 Point 5 Sqmm Single Core , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 4 Sqmm Single Core , Cable Pvc Insulated Electric Cables Heavy Duty Copper Conductor Of Size 2 Point 5 Sqmm Single Core , Pvc Casing Capping Of Size 1 Inch Medium Grade Snow White , Pvc Casing Capping Of Size 3 Oblique 4 Inch Medium Grade Snow White , Switch Piano 5 Amp 230 Volts Flush Type One Way Snow White , Led Tube Light Fittings 18 Oblique 20W Rechargeable 230V Box Type 4 Feets , Screw Full Thread 6 X 19Mm 200 Nos Per Pkt , Pvc Switch Board Snow White Size 7 Inch X 4 Inch For Sockets And Switches , Pvc Switch Board Snow White Size 8 Inch X 10 Inch For Main Switches Db , Pvc L Bend And T Junction Joint For Pvc Casing And Capping , Switch Socket Combination Snow White Multipurpose 2 In 1 Comma 15 Amp 230 Volts , Switch Socket Combination Snow White 5 Amp 230 Volts , Service Bracket 40Mm Dia Gi Tubing Medium Grade 1 Point 5 Mtr Long , Service Cable Pvc Insulated Aluminium Conductor Heavy Duty 25 Sqmm 4 Core , Ceiling Rose Three Terminal Snow White , Led Bulk Head Fitting With Led Lamp 10 Watts , Pvc Flexible Wire Copper Conductor Multi Stranded 0 Point 0016 Oblique 76 , Pvc Flexible Conduit Pipe 15 Mm Dia , Pvc Round Oblique Square Block , Fire Extinguisher Of One Kilogram Capacity Dry Power Type Along With Its Accessories , Change Over Switch 32 Amp 4 Pole Tpn , Earthing Plate 600 X 600 X 6 Mm Galvanised Steel Suitable For Gi Strip Fittings , Ci Earth Pit Cover Of Size 300 X 300 X 6 Mm With Angle Iron Of Size 20X20Mm , Funnel Fitted With 20 Mm Diameter Gi Pipe 1 Point 5 M Long Pipe , Gi Wire 4 Mm Diameter For Earthing , Charcoal , Salt Normal , Air Termination Single Pointed Aluminium Rod 12 Mm Dia And 300 Mm Long , Testing Point Terminal Block Make Of Gun Metal And Phosphorus Bronze Size 75 X 75 X 25 Mm Drilled , Aluminium Strips 25 X 3 Point 0 Mm , Galvanized Iron Strip 32 X 6 Mm , Insulating Pvc Block 75X75X30 Mm With Insulating Clamp Nut And Bolt , Individual Standalone Plastic Body Smoke Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Individual Standalone Plastic Body Heat Alarm With Adequate Provision For Fixing On Wall Oblique Ceiling Oblique Roof , Fire Ball Extinguisher Of 1 Point 3 Kg Wt With Suitable Provision For Wall Mounting , Double Sleeping Bunk Alongwith Rexene Sleeved Mattress , Steel Bed Side Locker Of Size 1000Mm X 1520Mm X 450Mm , Study Chair Of Size Length 56 Cm Comma Height 82 Cm And Width 56 Cm , Study Table Of Size 4 X 2 Wooden Top Round Tube Structure With Three Drawers , Looking Mirror Of Selected Quality Frameless Of Size 600 X 450 X 5Mm , Water Dispenser Of 230 V 500 Watts Without Refrigerator With Normal Cold And Heating Capacity Of 5 Ltrs , Portable Indoor Type High Quality Kero Heater Metal Body With Capacity 4 Ltr , Plastic Dustbin Of Capacity 40 Ltr , Kassi With Handle , Black Steel Sr Shovel Spade Belcha , Plaster Trowel With Wooden Handle , Showel Square Nose 14 Gauge Blade Size 310 X 245 Mm , Plumb Bob Iron , Crow Bar 1 Point 5 Inch Dia 4 Feet Long , Hammer 1 Kg With Wooden Handle , Hammer 0 Point 5 Kg With Wooden Handle , Brick Line 30 Mtr Nylon Dhaga , Traveler Brick Mason 4 Inch 305Mm , Sprit Level , Measuring Tape 30 Mtr Steel , Water Bucket Steel 13 Inch Dia , Picks Axes With Chisel And Point Ends Kudali 14 Cp Nominal Weight 3 Point 0 Kg , Lime Brush Best Quality , Painting Brush 100Mm Best Quality , Hacksaw Frame Large With Blade 05 Nos , Galvanised Iron Pan Mortar Tasla Comma 18 Gauge Comma 20 Inch Dia , Wooden Waterproof Plywood Comma Thickness 12 Mm , Nails Various Sizes , Rammer Earth With Handle , Tester For Electrician With Plastic Handle 150Mm , Electric Drill Machine Heavy Duty 500 W Electric Backup With Battery And Charger , Drill Bits Hss 5Mm Comma 8Mm And 10Mm For Electric Drill Machine , Electric Tile Cutting Machine With Interchangable Blades 20 Nos , Electric Sheet Cutter Machine With Blade 20 Nos , Puf Rivet Machine , Centre Punch 8Mm , Plumbing Tool Kit , Water Level Pipe 30 Mtr Total Quantity : 9012
Contract Date: Ref. Documents Contract Value : 68.95 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
34.
Defence #11288092 AOC
Bids Are invited for Excavation in trenches not exc 1 point 5 mtr wide and 1point 5 mtr deep , Excavation in trenches not exc 1 point 5mtr wide and 2 mtr deep , Returning filling spreadinglavelling watering and well ramming , Removing excavatedmaterial not exc 50 mtr , S and L 50mm outside dia doublecorrugated pipe , Stret light bracket welded and fixing inposition complete , Supply and fix steel tubular pole 410 SP22 , 20 mm stone aggregates , 40 mm stone aggregates ,PVC insulated water proof 1point 5 sqmm 3 core coppercable , S and F repair of 5KW 3 phase authomatic street lighttimer switch , Supply and fixing street light junction box size260mm by 210mm by 116mm , Wall Mounted Fan 400mmwith all complete accessories , Supply and fix water coolercapacity 80 Litre , Supply and fix Deep freezer glass top 320litres and having double door , Supply and fix refrigeratorcapacity 310 Litres BEE 5 star , Copper wire 1 point 5 sqmm2c with all accessories , switch socket combination 3 pin 5 or6A , Supply and fix switch socket combination 5 in 1 and 5or 16 Amps , M and L for Sub main wiring with 3 run ofsingle core 2 point 5 Sqmm , Supply install testing andcommissioning of 50 KVA Voltage stabilizer , M and L forpipe earthing galvanised steel 40mm bore , Supply and fixon load change over switch 4 pole 100a 415 Volt , LEDLuminaire For Road And Street Lights Conforming To IS10322 (Part 5/Section 3) (V3) (Under BIS Scheme - II) (Q2) ,XLPE Cable for Working Voltage up to and Including 1.1 KVMarked To IS 7098 (Part 1) (Q2) Total Quantity : 6337
Contract Date: Ref. Documents Contract Value : 29.54 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
West Bengal View Result →
35.
Power #11285862 AOC
Tender for Acsr 6/1/3.35 (50Mm²) {Includes 3 Conductor Lengths For 3F And Inclusive 3% (Sag, Jumpering And Wastage} , 11M Steel Tublar Pole (11 M, Working Load 227 Kgf/M²) (With Ruling Span 90 M, 8 No. Run Thro And 3 No. Double Pole Dead End Structures) , Muffs With Concerete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length: 1525 Mm I/C Tolerance Of 100 Mm Either Side) X 8 Structure , Angle Iron (50X50x6 Mm), Length: 750 Mm X 2 No. X 8 Structures , Pole Top Bracket [Msci:100X50x6 Mm- 100 Mm] , 22 Kv Pin Insulators With Gi Pin(Porcelain, 24 Kv, 10 Kn): 3 No Per Pole Structure , Belt Set - Ms Angle Iron: 50X50x6, Length :1800 Mm X 2 No. , X-Bracing Set - Ms Angle Iron: 50X50x6, Length: 2125 Mm X 2 No. , X-Arm (Horizontal) - Ms Channel Iron: 100X50x6, Length: 2340 Mm X 2 No.] ? Formation , Discs Insulator Sets On Dead End Structures (Comprising 1 No. Disc: ^^(Porcelain, Bs, 24 Kv, 90 Kn) Including Dead End Clamps Etc.) X (3 No. Conductors) X (2 No. Sides) , 22 Kv Pin Insulators (Porcelain, 24 Kv, 10 Kn): 3 No Per Double Pole Structure , Stay Set Complete In All Respect (1No. / Single Pole , 4 No. / Double Pole Structures) , Stay Wire (7/3.15 Mm) (10.0 Kg Per Stay Set) , Ht Earthing Set Complete (Rec construction Stand. J-1) , Single Continous Earth Wire (Gi, 8 Swg) {Alongwith 2 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% (Sag And Wastage)} @ 0.102 Kg/M , Cross Lacings (Gi, 8 Swg) [ 2.2 M X 9 Nos @ 2 M Spacing] {0.102 Kg/M} , Eye Hook For Earth Wire , Earth Wire Clamp , Ms Channel Iron: 75X40x6, Length : 2400 Mm For Road Crossing , Half Clamps: [On Double Pole Dead End Structure: 4 No; On Run Thro Structure: 2 No ] , Full Clamps: [On Double Pole Dead End Structure: 4 No, Single Pole Run Thro Structure: 2 No] , Danger Plate , Nuts And Bolts Of Various Sizes (Galvanised / Coated) [Preferably 16 Mm F Or More (With Flat And Spring Washers)] , Barbed Wire , Red Oxide , Aluminium Paint , Go Switch Handle Supporting: [Channel Iron (75X40x6 Mm), Le
Contract Date: Jun 18, 2026 Contract Value : 7.17 Crore
Government Departments No of Bidders 3
Himachal Pradesh View Result →
36.
Power #11285861 Price Bid
Tender for Acsr 6/1/3.35 (50Mm²) And Inclusive 3% (Sag, Jumpering And Wastage} , 11M Steel Tublar Pole (11 M, Working Load 227 Kgf/M²) , Muffs With Concerete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length: 1270 Mm I/C Tolerance Of 100 Mm Either Side) , Angle Iron (50X50x6 Mm), Length: 750 Mm , Pole Top Bracket [Msci:100X50x6 Mm] , 11 Kv Pin Insulators With Gi Pin(Polymeric, (12 Kv, 5 Kn) , Belt Set - Ms Angle Iron: 50X50x6, Length :1800 Mm , X-Bracing Set - Ms Angle Iron: 50X50x6, Length: 2125 Mm , X-Arm (Horizontal) - Ms Channel Iron: 100X50x6, Length: 2340 Mm , Discs Insulator Sets On Dead End Structures^^(Polymer, , Bs, 12 Kv, 90 Kn) , Stay Set Complete In All Respect , Stay Wire (7/3.15 Mm) , Ht Earthing Set Complete , Single Continous Earth Wire (Gi, 8 Swg) @0.102/Kg/M , Cross Lacings (Gi, 8 Swg) [ 2.2 M X 9 Nos @ 2 M Spacing] {0.102 Kg/M} , Eye Hook For Earth Wire , Earth Wire Clamp , Ms Channel Iron: 75X40x6, Length : 2400 Mm For Road Crossing , Half Clamps , Full Clamps , Danger Plate , Nuts And Bolts Of Various Sizes (Galvanised / Coated) [Preferably 16 Mm F Or More (With Flat And Spring Washers)] , Barbed Wire , Red Oxide , Aluminium Paint , Go Switch Handle Supporting: [Channel Iron (75X40x6 Mm), Length : 460 Mm , Go Ab Switch Unit (11Kv, 400A, 25 Ka ) Tripple Pole O/D Type Erection Part , Erection Of St Pole 11 Mtr Long (Single Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of St Pole 11 Mtr Long (Double Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of Stay Set Digging Of Pit,Fixing Of Stay Rod,Filling Of Pit & Nozzeling & Tighting & Filling Of Pit . , Erection Of Earthing Set Ht Digging Of Pit & Filling Of Pit, Fixing Of Stay Rod
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
37.
Power #11285860 Price Bid
Tender for Acsr 6/1/3.35 (50Mm²) And Inclusive 3% (Sag, Jumpering And Wastage} , 11M Steel Tublar Pole (11 M, Working Load 227 Kgf/M²) , Muffs With Concerete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length: 1270 Mm I/C Tolerance Of 100 Mm Either Side) , Angle Iron (50X50x6 Mm), Length: 750 Mm , Pole Top Bracket [Msci:100X50x6 Mm] , 11 Kv Pin Insulators With Gi Pin(Polymeric, (12 Kv, 5 Kn) , Belt Set - Ms Angle Iron: 50X50x6, Length :1800 Mm , X-Bracing Set - Ms Angle Iron: 50X50x6, Length: 2125 Mm , X-Arm (Horizontal) - Ms Channel Iron: 100X50x6, Length: 2340 Mm , Discs Insulator Sets On Dead End Structures^^(Polymer, , Bs, 12 Kv, 90 Kn) , Stay Set Complete In All Respect , Stay Wire (7/3.15 Mm) , Ht Earthing Set Complete , Single Continous Earth Wire (Gi, 8 Swg) @0.102/Kg/M , Cross Lacings (Gi, 8 Swg) [ 2.2 M X 9 Nos @ 2 M Spacing] {0.102 Kg/M} , Eye Hook For Earth Wire , Earth Wire Clamp , Ms Channel Iron: 75X40x6, Length : 2400 Mm For Road Crossing , Half Clamps , Full Clamps , Danger Plate , Nuts And Bolts Of Various Sizes (Galvanised / Coated) [Preferably 16 Mm F Or More (With Flat And Spring Washers)] , Barbed Wire , Red Oxide , Aluminium Paint , Go Switch Handle Supporting: [Channel Iron (75X40x6 Mm), Length : 460 Mm , Go Ab Switch Unit (11Kv, 400A, 25 Ka ) Tripple Pole O/D Type Erection Part , Erection Of St Pole 11 Mtr Long (Single Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of St Pole 11 Mtr Long (Double Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of Stay Set Digging Of Pit,Fixing Of Stay Rod,Filling Of Pit & Nozzeling & Tighting & Filling Of Pit . , Erection Of Earthing Set Ht Digging Of Pit & Filling Of Pit, Fixing Of Stay Rod
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Himachal Pradesh View Result →
38.
Power #11285859 Price Bid
Tender for Acsr 6/1/3.35 (50Mm²) And Inclusive 3% (Sag, Jumpering And Wastage} , 11M Steel Tublar Pole (11 M, Working Load 227 Kgf/M²) , Muffs With Concerete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length: 1270 Mm I/C Tolerance Of 100 Mm Either Side) , Angle Iron (50X50x6 Mm), Length: 750 Mm , Pole Top Bracket [Msci:100X50x6 Mm] , 11 Kv Pin Insulators With Gi Pin(Polymeric, (12 Kv, 5 Kn) , Belt Set - Ms Angle Iron: 50X50x6, Length :1800 Mm , X-Bracing Set - Ms Angle Iron: 50X50x6, Length: 2125 Mm , X-Arm (Horizontal) - Ms Channel Iron: 100X50x6, Length: 2340 Mm , Discs Insulator Sets On Dead End Structures^^(Polymer, , Bs, 12 Kv, 90 Kn) , Stay Set Complete In All Respect , Stay Wire (7/3.15 Mm) , Ht Earthing Set Complete , Single Continous Earth Wire (Gi, 8 Swg) @0.102/Kg/M , Cross Lacings (Gi, 8 Swg) [ 2.2 M X 9 Nos @ 2 M Spacing] {0.102 Kg/M} , Eye Hook For Earth Wire , Earth Wire Clamp , Ms Channel Iron: 75X40x6, Length : 2400 Mm For Road Crossing , Half Clamps , Full Clamps , Danger Plate , Nuts And Bolts Of Various Sizes (Galvanised / Coated) [Preferably 16 Mm F Or More (With Flat And Spring Washers)] , Barbed Wire , Red Oxide , Aluminium Paint , Go Switch Handle Supporting: [Channel Iron (75X40x6 Mm), Length : 460 Mm , Go Ab Switch Unit (11Kv, 400A, 25 Ka ) Tripple Pole O/D Type Erection Part , Erection Of St Pole 11 Mtr Long (Single Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of St Pole 11 Mtr Long (Double Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of Stay Set Digging Of Pit,Fixing Of Stay Rod,Filling Of Pit & Nozzeling & Tighting & Filling Of Pit . , Erection Of Earthing Set Ht Digging Of Pit & Filling Of Pit, Fixing Of Stay Rod
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Himachal Pradesh View Result →
39.
Power #11285858 Price Bid
Tender for Acsr 6/1/3.35 (50Mm²) And Inclusive 3% (Sag, Jumpering And Wastage} , 11M Steel Tublar Pole (11 M, Working Load 227 Kgf/M²) , Muffs With Concerete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length: 1270 Mm I/C Tolerance Of 100 Mm Either Side) , Angle Iron (50X50x6 Mm), Length: 750 Mm , Pole Top Bracket [Msci:100X50x6 Mm] , 11 Kv Pin Insulators With Gi Pin(Polymeric, (12 Kv, 5 Kn) , Belt Set - Ms Angle Iron: 50X50x6, Length :1800 Mm , X-Bracing Set - Ms Angle Iron: 50X50x6, Length: 2125 Mm , X-Arm (Horizontal) - Ms Channel Iron: 100X50x6, Length: 2340 Mm , Discs Insulator Sets On Dead End Structures^^(Polymer, , Bs, 12 Kv, 90 Kn) , Stay Set Complete In All Respect , Stay Wire (7/3.15 Mm) , Ht Earthing Set Complete , Single Continous Earth Wire (Gi, 8 Swg) @0.102/Kg/M , Cross Lacings (Gi, 8 Swg) [ 2.2 M X 9 Nos @ 2 M Spacing] {0.102 Kg/M} , Eye Hook For Earth Wire , Earth Wire Clamp , Ms Channel Iron: 75X40x6, Length : 2400 Mm For Road Crossing , Half Clamps , Full Clamps , Danger Plate , Nuts And Bolts Of Various Sizes (Galvanised / Coated) [Preferably 16 Mm F Or More (With Flat And Spring Washers)] , Barbed Wire , Red Oxide , Aluminium Paint , Go Switch Handle Supporting: [Channel Iron (75X40x6 Mm), Length : 460 Mm , Go Ab Switch Unit (11Kv, 400A, 25 Ka ) Tripple Pole O/D Type Erection Part , Erection Of St Pole 11 Mtr Long (Single Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of St Pole 11 Mtr Long (Double Pole) Digging Of Pit,Filling Of Pit And Ramming,Fixing Of Insulator,X-Bracing Set ,X-Arms,Knee Bracing Set ,Drilling Of Holes In X-Bracing Set,X-Arms, Fixing Of Barbed Wire And Erection Of Pole. , Erection Of Stay Set Digging Of Pit,Fixing Of Stay Rod,Filling Of Pit & Nozzeling & Tighting & Filling Of Pit . , Erection Of Earthing Set Ht Digging Of Pit & Filling Of Pit, Fixing Of Stay Rod
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
40.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
41.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
42.
Power #11272331 Technical Bid
Tender for Rate Contract For Supply Of Material Required For Repair/Maintenance /Restoration Of 33Kv Lines And 33/11Kv Receiving Stations In Respect Of Std-Iv Kalakote, For The Year 2026-27 Or Till Next Contract. , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 120 Mm2 , R) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 185 Mm2 , S) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 240 Mm2 , T) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 300 Mm2 , U) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 400 Mm2 , V) Cable Kits 11 Kv Single Core (Straight Through Joint), Heat Shrinkable 630 Mm2 , W) Cable Kits 33 Kv Single Core (Straight Through Joint), Heat Shrinkable 630 Mm2 , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii) 750/375/5-5 , Iii) 600/300/5-5 , Iv) 400/200/5-5 , V) 300/150/5-5 , Vi) 150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 1.6 Mva 33/11 Kv Transformer (Kg) , C) Breather For 3.15 Mva 33/11 Kv Transformer (Kg) , D) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , E) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , F) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , G) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , H) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , I) 12 Mm Copper Bush Rod Assembly For 33/11 Kv, 6.3 Mva Power Transformer With Oil Seal , J) Silica Gel , K) Oil Seal For 33/11 Kv Power Transformer , L) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Relays A) Numerical Relay (24-50 V) 3 O/C And 1 E/F Relay Of Different Make .(Scada Compatible) , B) Numerical Relay (24-50 V) 3 O/C And 1 E/F Relay Of Different Make.(Non-Scada Compatible) , C) Master Trip Relay 24-50 V ,Of Different Make , 33 Kv & 11 Kv Insulators Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , I) 11 Kv Disc Insulator (B & S Type) 120 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) Shackle Insulator , P) 11 Kv Guy Insulator , Q) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type , 33 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor (Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsr Panther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsr Wolf Conductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsr Dog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal (Isi Standard) , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape( Isi Standard) , Empire Tape , Para Plast Compound , Earth Wire 7/22 , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Gi Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Light Chargable Is Standard , Led Light (30/60 W) With Bracket And Fitting Complete (Is Standard) , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots Is Specification , Search Light / Dragon Light With In Built Charging System , Hand Gloves 33 Kv (Is Specification) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Earth Tester Heavy Duty Is Specifications , Megger 5000 V 10000 Meg Ohm Is Specifications , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , annual periodical maintenance Meter 0-400 A , Voltmeter 0-300V , Drill Machine With Stand Heavy Duty Is Standard , I/C Switch 200 annual periodical maintenance , Fire Extinguisher Cylinder For Electrical Sub Stations Of Relevant Is Specifications(6Kg) , Fire Buckets , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 annual periodical maintenance (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 annual periodical maintenance (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 annual periodical maintenance (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 annual periodical maintenance (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 33 Kv Hgf Set , 11 Kv H G Set , 11 Kv D O Set , 11 Kv G O Set , 11 Kv Link Set , Steel Tublar Pole 13 Mtr Long(St-410, Sp-69) , Steel Tublar Pole 13 Mtr Long(St410, Sp-56) , Steel Tublar Pole 13 Mtr Long(St410, Sp-33) , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank & Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cells Complete With All Accessories Make: Exide/Amaron , B) 36 annual periodical maintenance Manually Operated Battery Charger. , C) Maintenance Free 36V Lead Acid Battery (Vrla) Bank Comprising Of 18 Nos Of 2 Volt Cells Of 100 Ah Capacity Make: Exide/Amaron Or Equally Reputed Make , D) 36 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 36Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Cell 2 Volt Is Specification Make: Exide/Amaron Or Equally Reputed Make , Lightening Arrestors (10 Ka, Make Oblum Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 11 Kv L.A. Set (Station Type) Polymer , B) 33 Kv L.A. Set (Station Type) Polymer , C) 11 Kv L.A. Set (Station Type) Porcelain , D) 33 Kv L.A. Set (Station Type) Porcelain , Control Cable A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle Of Different Make(G.E.C.,Crompton Greaves,Alstrom,Bhel Etc , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 , B) 11 Kv Single-Core Xlpe Cable 630 Mm2 , C) 11 Kv 3-Core Xlpe Cable 400 Mm2 , D) 11 Kv 3-Core Xlpe Cable 300 Mm2 , E) 11 Kv 3-Core Xlpe Cable 240 Mm2 , F) 11 Kv 3-Core Xlpe Cable 185 Mm2 , G) 11 Kv 3-Core Xlpe Cable 120 Mm2 , H) 11 Kv 3-Core Xlpe Cable 95 Mm2 , I) Pvc Cable 2-Core 12 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured 35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm Φ (1½) , E) G.I. Pipe 50 Mm Φ (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , Chemical Earthing Complete , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendments Up To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb(Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firms Conforming To Relevant Is With Latest Amendments). , 33 Kv C&R Transformer Panel With Differential Protection(Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firms Conforming To Relevant Is With Latest Amendments). , 33 Kv C&R Line Panel(Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firmsconforming To Relevant Is With Latest Amendments). , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Panther Conductor , Tarpin Oil , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Welding Set 3 Phase Heavy Duty Is Specification , Welding Set Single Phase Heavy Duty Is Specification , Led Bulb Is Standard 6/9 Watt , Led Bulb Is Standard 15/20/30 Watt , Cfl 30/60 Watt Is Standard , Led Flood Light 50 Watt Complete Is Specification , Laptop For Office Use Of Reputed Make , Ratched For Dog Conductor/Cable Puller , Comelong Clamp For Dog/Wolf Conductor , Wire Cutter 24 To 36 ( Heavy Duty) , Telescopic Running Saw Length 11 Mtr (Branch Cutter) , Cable Fault Locator (Digital) Is Speciation , Telescopic (Range 4Km To 5Km) , Discharge Rod/Earthing Rod 11Kv , Aluminium Ladder (Telescopic Type, 20 Feet) Is Standard , 11Kv Vcb Incomer Panel (Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firmsconforming To Relevant Is With Latest Amendments). , 11Kv Vcb Outgoing Panel (Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firms Conforming To Relevant Is With Latest Amendments). , Lifting Pulley Machine (5-8Mt) , Lifting Pulley Machine (3-5Mt) , Chequered Plate 5Mm To 10Mm , Oil Testing Machine Of Reputed Make , Multimeter Digital Of Reputed Make , Log Book For Receiving Stations , Discharge Rod/Earthing Rod 33Kv , 33Vcb Bottle Of Reputed Make , Galvanised Channel Iron Cross Arm 10Feet Long (10X50x6) , Galvanised Channel Iron Cross Arm 8Feet Long (10X50x6) , Galvanised Angle Iron Brace Arm 10Feet Long (50X6) , Galvanised Angle Iron Brace Arm 8Feet Long (50X6) , Galvanised Angle Iron Brace Arm 6Feet Long (50X6) , Galvanised Cross Clamps Of Sorts , Galvanised Guy Rod Assembly Complete , Ms Channel Iron Cross Arm 10Feet Long (10X50x6) , Ms Channel Iron Cross Arm 8Feet Long (10X50x6) , Ms Angle Iron Brace Arm 10Feet Long (50X6) , Ms Angle Iron Brace Arm 8Feet Long (50X6) , Ms Angle Iron Brace Arm 6Feet Long (50X6) , Ms Cross Clamps Of Sorts , Ms Guy Rod Assembly Complete , 11Kv Pt Of Reputed Make , Vacuum Interrupter Testing Kit Of Reputed Make , Relay Testing Kit Of Reputed Make , Primary Injection Set Of Reputed Make , Professional Electric Iron Cutting Machine With Handle (Rated Voltage 2 Kw To 2.5Kw) , Turn Ratiometer Of Reputed Make , 11Kv Vcb Tripping / Closing Coil , 33Kv Vcb Tripping / Closing Coil , Petrol Chainsaw Tree Cutter 18 40Cc , Petrol Chainsaw Tree Cutter 18 50Cc , Electrical Rescue Rod Frp Hv 6 Feet Length , 11Kv Vcb Trolly Suitable For Cg, Abb, Electric Field Etc. , Magnetic Drill Machine (Hd) , Bits Suitable For Magnetic Drill Mc Complete Set , Digital Insulation Tester 5Kv , Welding Set Portable Modern Type , Petrol Chainsaw Tree Cutter 18 50Cc , Petrol Chainsaw Tree Cutter 20 40Cc , Petrol Chainsaw Tree Cutter 20 50Cc
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
43.
Defence #11271181 Technical Bid
Tender for Dismantling And Taking Up Or Down Old Unserviceable Service Cable Amd Lt Ug Cable Of Any Size Complete All As Specified And Directed , Supply And Laying And Connecting With Appropriate Lugs In Replacement Xlpe Lt Cable Pvc Insulated, Heavy Duty Electric Cables With Aluminum Conductors,1100 Volts Grade, Laid In Trenches/On Pole/In Pipe /On Wall ,Using Suitable Clamps For Fixing Of Cable Complete All As Specified And Directed Of Following Cross-Sectional Area :-10 Sqmm 2 Core , 25 Sqmm 3.5 Core , 35 Sqmm 3.5 Core , 50 Sqmm 3.5 Core , 70 Sqmm 3.5 Core , 95 Sqmm 3.5 Core , 120 Sqmm 3.5 Core , Excavation In Trenches, N Exc 1.5M Wide And N. Exc 1.5M In Depth, For Foundation, Etc Or For Shafts, Wells, Cess-Pits, Menholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And N Exc 1.5M In Depth And Getting Out For Hard/Dense Soil. , Returning, Filling In, Including Spreading, Levelling, Waterring And Wall Ramming In Layers Not Exc 25 Cm. For Hard/Dense Soil. , Removing Excavated Material N Exc. 50 M And Depositing Where Directed At A Layers Not Exc 25 Cm. For Hard/Dense Soil. , S&F Double Walled Corrugated (Dwc) Pipe Conforming To Is 14930(Part-Ii) Pipes Of Outer Dia 63 Mm And Innder Dia 50Mm Including Taking Out Old Unserviceable Pipeall As Specified And As Directed. , S&F Double Walled Corrugated (Dwc) Pipe Conforming To Is 14930(Part-Ii) Pipes Of Outer Dia 90 Mm And Innder Dia 76Mm Including Taking Out Old Unserviceable Pipeall As Specified And As Directed. , Supply And Fixing In Replacement Mccb 4 Pole, 415 V, 250 Amps With Breaking Capacity 36 Ka Complete With All Accessories All As Specified And Directed. , Supply And Fixing In Replacement Mccb 4 Pole, 415 V, 160 Amps With Breaking Capacity 36 Ka Complete With All Accessories All As Specified And Directed. , Supply And Fixing In Replacement Mccb 4 Pole, 415 V, 125 Amps With Breaking Capacity 16 Ka Complete With All Accessories Including Taking Out Old Unserviceable Mccb All As Specified And Directed. , Supply And Fixing In Replacement Mccb 4 Pole, 415 V, 100 Amps With Breaking Capacity 16 Ka Complete With All Accessories Including Taking Out Old Unserviceable Mccb All As Specified And Directed. , Supply And Fixing In Replacement Mccb 4 Pole, 415 V, 63 Amps With Breaking Capacity 16 Ka Complete With All Accessories Including Taking Out Old Unserviceable All As Specified And Directed. , M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6mm Thick, Burried Directly In Ground (Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level)With Top Edge Of The Plate Not Less Than 1.5 Metres Below Normal Groundlevel, Connected To Galvanised Earth Lead Strip 32X6mm By Means Of Volts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No-5 Of Ssr Part-I Connected To Earthing Test Point All As Specified Or Indicated Including Excavation And Connected Earth Work In Hard/Dense Soil, Plain Cement Concrete 1:3:6 Type C-1 As In Pit, 20Mm Dia Gi Pipe Medium Grade For Watering Pipe, 15 Mm Bore Gi Medium Grade Earth Lead Protection Pipe, 50 Mm Thick Reinforced Cement Concrete 1:2:4 Type B-1 Cover Slab Of Earth Pit Reinforced With 8 Mm Dia Tmt Bars @ 10 Cm C/C Both Ways And With Handle Made Out Of 10 Mm Dia Bars, Funnel, Strainer,Charcoal And Testing On Completion Including Dismantling Of Old Unserviceable Earthing All As Specified And Directed.. , M&L For Pruning Of Tree Branches Which Is Touches On Lt/Ht Over Head Conductor. , M&L In Replacement Gi Pipe Light Grade With All Fittings Complete Grouted In Ground All As Specified For The 40 Mm Bore Of Pipe Laid In Trenches/Fixed With Poles/Laid In Road/Plinth/Floor For Protection Of Cable Including Taking Out Old Unserviceable Pipe Complete All As Specified. , M&L In Replacement Gi Pipe Light Grade With All Fittings Complete Grouted In Ground All As Specified For The 50 Mm Bore Of Pipe Laid In Trenches/Fixed With Poles/Laid In Road/Plinth/Floor For Protection Of Cable Including Taking Out Old Unserviceable Pipe Complete All As Specified. , M&L In Replacement Gi Pipe Light Grade With All Fittings Complete Grouted In Ground All As Specified For The 80 Mm Bore Of Pipe Laid In Trenches/Fixed With Poles/Laid In Road/Plinth/Floor For Protection Of Cable Including Taking Out Old Unserviceable Pipecomplete All As Specified. , M&L For Locating Of Electrical Fault In Feeder Pillar/ Lt Electric Panel/Mcb Db/Busbar Chamber/Changeover Switch Of Any Size And Repair By Using Of Suitable Size Of Cable Lugs/Nut & Bolts And Make The Good Disturbed Surfaces All As Specified And Directed By Engr-In-Charge. , M & L For Painting Of Steel Tubler Pole Up To 9 Mtr Long By Using Two Coats Of Aluminium Paint With One Coat Of Red Oxide Primer.All As Directed By Engr - In - Charge , Supply And Fix Lt Cable Jointing Kit For 1100 Volt Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 6 To 16 Sqmm 3.5/ 4 Core,Outdoor Type All As Directed And As Specified. , Supply And Fix Ltcable Jointing Kit For 1100 Volt Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 25 To 50 Sqmm 3.5/ 4 Core,Outdoor Type Outdoor Type All As Directed And As Specified. , Supply And Fix Lt Cable Jointing Kit For 1100 V Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 70 To 95 Sqmm 3.5/ 4 Core,Outdoor Type Outdoor Type All As Directed And As Specified. , Supply And Fix Lt Cable Jointing Kit For 1100 V Grade Cable For Straight Through Joint Complete With Jointing Material Heat Shrink Type And Accessories Suitable For 120 To 185 Sqmm 3.5/ 4 Core,Outdoor Type Outdoor Type All As Directed And As Specified. , Supply And Fixing Led Street Light Fitting 60 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65/66 Protection Including Taking Out Old Unserviceable Street Light Complete . Make Havells/Cg/Bajaj/Phillips , Supply And Fix On Load Changeover Switch Side Handle In Sheet Enclosure 415 V Ac 50 Hz Of Capacity 63 annual periodical maintenance 4 Pole Including Taking Out Old Unserviceable Changeover Switch All As Directed By Engr- In- Charge Make : Havells ,L&T,Legrand And Its Equivalent , Supply And Fix On Load Changeover Switch Side Handle In Sheet Enclosure 415 V Ac 50 Hz Of Capacity 100 annual periodical maintenance 4 Pole Including Taking Out Old Unserviceable Changeover Switch All As Directed By Engr- In- Charge Make : Havells ,L&T,Legrand And Its Equivalent , Supply And Fix On Load Changeover Switch Side Handle In Sheet Enclosure 415 V Ac 50 Hz Of Capacity 160 annual periodical maintenance 4 Pole Including Taking Out Old Unserviceable Changeover Switch All As Directed By Engr- In- Charge Make : Havells ,L&T,Legrand And Its Equivalent , Supply And Fix On Load Changeover Switch Side Handle In Sheet Enclosure 415 V Ac 50 Hz Of Capacity 250 annual periodical maintenance 4 Pole Including Taking Out Old Unserviceable Changeover Switch All As Directed By Engr- In- Charge Make : Havells ,L&T,Legrand And Its Equivalent , S&F Of Aluminium Lugs Of Following Sizes:- A)10 Sq Mm , B)16 Sq Mm , C)25 Sq Mm , D)35 Sq Mm , E)50 Sq Mm , F)70 Sq Mm , G)95 Sq Mm , H)120 Sq Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
44.
Defence #11271178 Technical Bid
Tender for Taking Down Carefully Aluminium Point Wiring (Light, Fan, Socket Or Power) Complete And Making Good Disturbed Surfaces Of Walls, Floors, Etc. All As Directed.Including Taking Down Fittings Such As Switches, Ceiling Roses, Regulators, Sockets,Lamp Holders Etc. , M&L For Point Wiring With Two Runs Of Frlsh Pvc Insulated Unsheathed, 1100 V Grade Cable Multi Stranded Copper Conductor Of Size 1.5 Sqmm Drawing Through In And Including Pvc Casing Capping Of Size Not Less Than 20Mm On Surface Of Wall Including Provn Of Pvc Box/Modular Metal Flush Box Of Suitable Size For Mounting Switch, Socket And Regulator Along With Earth Wire Of Pvc Insulated, Unseathed, 1100 V Grade Cable Multi Stranded Copper Conductor Of Size 1.5 Sqmm All As Specified And Directed.One Light/Fan/Call Bell Point Controlled By One Switch One Way 5 Amps. , All As Per Sl Item No.2 But With One 2/3 Pin Socket Outlet 5Amps On Independent Board. , All As Per Sl Item No.2 But With One 3 Pin Socket Outlet 5 Amps On The Same Board With Other Switches , All As Per Item No 2 Above But One Switch Socket Combination 15 Amps On Independent Board With Cable 2.5 Sq Mm Size And Earth Wire 2.5 Sqmm . , S&F Switch Piano Flush Type Single Pole One Way Switch 5 Amps. , S&F Switch Socket Combination 2 In 1, 5 Amps Flush Type. , S&F Switch Socket Combination 2 In 1, 3 Pin, 6 And 16 annual periodical maintenance Flush Type Universal All As Specified And Directed. , S&F Ceiling Rose Surface Bakelite 3 Terminals 65X50mm All As Directed. , Supply And Fixing Led Lights Fitting 1X 18W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceilingrose Complete. , Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete. , Supply And Fix In Repair Modular Switch 1Way 6A,1Module , Supply And Fix In Repair Modular Switch 1Way 16A,1Module , Supply And Fix In Repair Modular Socket, 6A-2/3 Pin Combined 2 Module , Supply And Fix In Repair Modular Socket, 6A/16A-2/3 Pin Combined 2 Module , S&F In Repair Lamp Holder Angle Type Made Of Pvc/Polycarbonate With Back Plate. , Supply And Fixing Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, 220 V Ac Surface / Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete. , Supply And Fixing Round/Square Shape 12 Watt 220 Volts Ac Surface/Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Drivers, Holders, Led Lamp Suitable For Roof Ceiling Including Connecting Up With Three Core Flexible Copperconductor Cable Of Suitable Size Complete. , Supply And Fixing Round/Square Shape 15 Watt 220 Volts Ac Surface/Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Drivers, Holders, Led Lamp Suitable For Roof Ceiling Including Connecting Up With Three Core Flexible Copperconductor Cable Of Suitable Size Complete. , Supply And Fixing In Replacement Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65/66 Protection Including Taking Down Old Unserviceable Light Fitting Complte. , S & F Led Light Fitting 1X9w/1X10wbulkhead Luminaires Including Led Light Driver Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size. , S&F In Replacement Of Mccb 125 Amps 4 Pole 16 Ka 415 Volt Complete Including Taking Down All As Specified & Directed. , S&F In Replacement Of Mccb 100 Amps 16 Ka 4 Pole Complete All As Specified & Directed. , S&F In Replacement Of Mccb 63 Amps 10Ka Complete All As Specified & Directed. , S&F In Replacement, Sheet Metal Enclosure Distribution Box Suitable For Mcbs 4 Way Tpn 415 Volts With 200 Amps Rated Bus Bar Double Door Complete Including Connecting Up All As Specified And Making Good Distrubed Surface , All As Per Item No. 27 Above But 8 Way Spn With 200 Amps Rated Bus Bar , 240 Volts , All As Per Item No 27 Above But 4 Way Spn With 200 Amps Rated Bus Bar , 240 Volts , S&F In Replacement Mcb Single Pole, 240 Volts 5 To 32 Amps 10 Ka Rupturing Capacity, C Series , S&F In Replacement Mcb Single Pole, 240 Volts 40 Amps 10 Ka Rupturing Capacity, C Series , S&F In Replacement Mcb Single Pole & Neutral 240Volts 20 To 32 Amps, 10Ka Rupturing Capacity, C Series , S&F In Replacement Mcb Triple Pole 415 Volts 25 To 63 Amps 10Ka Rupturing Capacity, C Series. , Taking Down Sub Main Wiring Of Any Size Complete All As Specified And Directed. , M&L For Sub Main Wiring With Two Single Core Stranded Copper Conductor Unsheathed Pvc Insulated Cable 1100V Grade, 4 Sq Mm Drawn Through Suitable Size Of Non-Metallic Pvc Rigid Conduit With 4 Sqmm Copper Conductor Cable As Earth Conductor Of 4.0 Sq Mm And Conduit Accessories Fixed Up In Surface Including Connecting Up Complete All As Specified And Directed. , M&L For Sub Main Wiring With Two Single Core Stranded Copper Conductor Unsheathed Pvc Insulated Cable 1100V Grade, 6 Sq Mm Frlsh Drawn Through Suitable Size Of Non-Metallic Pvc Rigid Conduit With 6 Sqmm Copper Conductor Cable As Earth Conductor Of 6.0 Sq Mm Frlsh And Conduit Accessories Fixed Up In Surface Including Connecting Up Complete All As Specified And Directed. , M&L For Replacement Of Submain Wiring Alongwith Earth Wire With 4X10.0 Sq. Mm +1X10.0 Sq. Mm Earth Wire Sq Mm Sizes Of Frls For Is Pvc Insulated Copper Conductor, Single Core Cable In Existing /Surface/Recessed As Required In Pvc Conduit. , Taking Down Exhaust Fan Of Any Size Type And Make After Disconnecting The Electrical Connections ,Cleaning, Servicing , Greasing Removing And Replacing All The Unserviceable Spare ,Painting With Two Coats Of Synthetic Enamel Paint By Means Of Suitable Spray Gun After Cleaning And Prepairing The Suface Including Writing The Mes No. ,Fixing The Same Back To The Original Location All As Directed. Note For Item No. 40, 41 & 42 : (I) All The Replaced Spare For Unserviceable Spares Will Be Measured And Paid Separately (Ii) The Rate Quoted Shall Be Deemed To Include The Cost Of Painting And Minor Spares Such As Split Pin , Screws Washers Etc. , Supply Only Ball Bearing Suitable For Exhaust Fans 300/450Mm Dia Sweep. , Supply Only Capacitor 4 Mfd For Exhaust Fans. , Supply Only Gun Metal Bush Suitable For Exhaust Fans Of 300/450 Mm Sweep. , Supply Only Twin Core Flexible Wire 1 Sqmm For Connecting Up Ceiling Fans, Exhaust Fans/Wall Mounting Fan Etc. , Taking Down Old Burnt Out Copper Winding Wire From Exhaust Fan Of Any Sweep And Rewinding By Using The Same Gauge Of Copper Wire Super Enameled Including Heating And Varnishing,Cleaning, Servicing,Greasing ,Refixing At Siteand Testing For Smooth Functioning Complete All As Specified & Directed. , Supply Only Modular White Cover Plate With Frame, 2 Module Isi Marked Complete All As Specified And As Directed. , Supply Only White Cover Plate With Frame, 4 Module Isi Marked Complete All As Specified And As Directed. , Supply And Fix White Cover Plate With Frame, 6 Module Isi Marked Complete All As Specified And As Directed. , Supply Only White Cover Plate With Frame, 8 Module Isi Marked Complete All As Specified And As Directed. , Earthing Complete With Gi Earth Electrode Of Size 60Cmx60cmx6mm Buried Directly In Ground Vertically At A Depth Not Less Than 2.25 Metre Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Metre Below Normal Ground Surrounded From All Sides By 15Cm Thick And Packed Layer Of Charcoal Dust And Conmmon Salt Filling In Alternate Layers Connected To And Including Gi Earth Wire 4.0 Mm Dia Upto 7.5 Mtr By Means Of Bolts, Nuts, Check Nuts And Washers, And Protected By Light Grade 20 Mm Dia And Connected To Main Control Board And Gi Pipe Medium Grade 20Mm Bore For Watering And Including Funnel Wire Mesh, Reinforced Cement Concrete Pit Cover 50Mm Thick With 10Mm Dia Reinforcement 100Mm C/C And Plain Cement Concrete Chamber Pit With P C C 1:2:4 Type C2 (Including Excavation And Earth Work, Disposal Of Surplus Soil To A Distance Not Exceeding 50 Metre And Testing After Completion Including Dismantling Of Old Unserviceable Earthing All As Specified And Shown On Plate No 3 Of Ssr Part-I 2009 , S&F In Replacement Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried Inground Or Drawn In Conduit/Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required 4Mm Dia Galvanised Iron Or Steel Wire , S&F In Replacement For 20 Mm Bore Galvanised Steel Water Tubing Medium Grade With All Fitting Laid In Trenches Including Taking Out Old Unserviceable Pipe Complete All As Specified. , Repair / Servicing Including Trouble Shooting /Repair Of Geyser 25 To 50Ltrs Capacity Checking Of Serviceability Of Individual Parts Such As Thermostat, Heating Element, Pressure Release Valve, Inlet/Outlet Connections Etc, Replacing Worn-Out Fasteners And Defective Components And Testing Including Taking Down The Geysers And Refixing The Same After Repairs. Note : Spare Parts Including Replacement Will Be Measured And Paid Separately Under Relevant Item. Rate Quoted Shall Include Replacement Of Worn-Out Fasteners. , Supply Only Heater Coil Of Geyser All 1.5 Kw As Per Existing Make / Model / Size Conforming To Relevant Is.(As Required At Site) , All As Per Item No 53 Above But 2.0 Kw (As Required At Site) , Supply Only Thermostat For Any Type /Make/Capacity Of Geyser .(As Required At Site) , Supply Only Pressure Release Valve 15Mm Dia With New One For Any Type /Make/Capacity Of Geyser . , Supply Only Pvc Flexible Connection Of 15 Mm Dia 600 Mm Long With Check With New One Suitable For Cold/Hot Water Connection Of Geysers , Supply And Fix In Replacement 20 Mm Non Return Valves, Cast Copper Alloy, For Gi Pipes Pipe All As Directed , Taking The Copper Or Steel Container Carefully From The Geyser, Descaling, Rectifying Leakage By Braising, Resetting The Insulating (Glass Wool), Testing For The Required Pressure Replacing Rubber Gaskets, Worn-Out Fasteners Etc,. With New Ones Complete All As Directed By Engineer In Charge. , Supply And Fix Base Plate Of Water Heater Of 25 / 50 Ltrs Capacity All As Directed , S&F In Replacement Of Single Pole And Neutral Sheet Metal Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb Sp 20 Amps, 240 Volts, Ac,50 Hz, Completete All As Directed And Specified, Including Taking Down Old Unserviceable Plug Socket And Offering For Credit.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
45.
Power #11267487 Technical Bid
Tender for Rate Contract For Procurement Of Material In Respect Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized , Procurement Of Material In Respect Of Std Ganderbal For The Year 2025-26 Or Till Next Stage Contract Is Finalized , 11 Kv Horn Gap Fuse Set 3 Phase 200A , 11Kv Link Rods For 11Kv Link Set 22 Feet Long With Insulating Bottom Grip Bamboo/Carbon Fibre , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 11 Kv Isolator, Double Break,3-Pole, 600Amp, Horizontal Mounting Type, With Earth Switch Complete Including Clamps And Fittings , 11 Kv 3-Core Current Transformer 800-400/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 750-375/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 600-300/5-5 A, ( Metering, Protection, Differential Core) , 11 Kv 2-Core Current Transformer 600-300/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 400-200/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 100-50/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 50-25/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 20-10/5-5 A, ( Metering, Protection) , 11 Kv Potential Transformer 110V, Accuracy Class 0.5 , Tension Fittings For 0.1 Acsr Conductor 70Kn , Tension Fittings For 0.15 Acsr Conductor 70 Kn , Tension Fittings For 0.2 Acsr Conductor 120 Kn , 185 Sqmm, 3Core , 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 3 Core ,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core, 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 240 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 120 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 120 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 11 Kv 630 Mm² Single Core Xlpe Cable Armoured, Frls (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , Tripping And Closing Coils Must Have Burden Between 250 To 350 Watts At 30V Dc With Housing , Tripping Coil Of 11Kv Alind Make Vcb , Tripping Coil Of 11 Kv Er/Vijai Make Vcb , Tripping Coil Of 11Kv Electric Field Make Vcb , Tripping Coil Of 11Kv Abb Make Vcb , Tripping Coil Of 11Kv Crompton Make Vcb , Tripping Coil Of 11Kv Stelmac Make Vcb , Tripping Coil Of 11Kv Sudhir/Schneider Make Vcb , Tripping Coil Of 11Kv Pascal Make Vcb , Closing Coil Of 11Kv Alind Make Vcb , Closing Coil Of 11 Kv Er/Vijai Make Vcb , Closing Coil Of 11Kv Electric Field Make Vcb , Closing Coil Of 11Kv Abb Make Vcb , Closing Coil Of 11Kv Crompton Make Vcb , Closing Coil Of 11Kv Stelmac Make Vcb , Closing Coil Of 11Kv Sudhir/Schneider Make Vcb , Closing Coil Of 11Kv Pascal Make Vcb , 33 Kv Link Set Heavy Duty- Post Type, 800A Complete , 33Kv Link Rods Fibre/Bamboo Oil Impregnated With Insulated Bottom Grip 30 Feet Long , 33Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm. , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type A , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type B For 0.2 Acsr Conductor , 30 Kv Lightening Arrestor Set, 10 Ka, Station Class, Zno, Polymer Gap Less (Set Consists Of 03 No.) With All Accessories Required For Installation. , 33 Kv Isolator Without Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Isolator With Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Current Transformer (33 Kv, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. Per Φ) 3-Core, 0.5 5P10, Ps-Class 3 Core- With All Accessories Required For Installation , 400-200/5-5 A (Metering, Protection And Differential Core ) , 250-125/5-5 A (Metering, Protection And Differential Core ) , 33 Kv Voltage Transformer (33 Kv/110 V, 1Φ, Multi-Core, Outdoor), (1No. Per Φ) With All Accessories Required For Installation , Tripping Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb) , Closing Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb, Stelmac Etc ) , 33 Kv Polymer Post Insulator 36Kv,170Kv Impulse, Creepage Distance 1224M , Earthing Complete (Spike Earthing Rod 20Mm,2.5 Mtr Long) , Galvanised Earthing Strips 50X6 Mm/ 25X3mm , Galvanised Nuts & Bolts Of Different Sizes And Sorts , Pg Clamps For 0.1 Acsr Conductor 400A Pressure Di-Cast , Pg Clamps For 0.15 Acsr Conductor 500A Pressure Di-Cast , Pg Clamps For 0.2 Acsr Conductor 630A Pressure Di-Cast , Prefabricated Galvanised Channel Iron/ Angle Iron Of Different Sorts As Required , Prefabricated Galvanised Flat Iron Of Sorts 50/25 8/6Mm Thick , Instrument, Tools And Other Equipments , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick With Sliding Mechanism , Bamboo Ladder 25 Long , 12V/7Ah Led Handheld Searchlight (Andslite/Philipls/Microtech,Fos) , Tool Kit Of Suitable Size With Tools ( Stanley / Taparia/Jon/Jk/ Make) Comprising Of :- Double End Spanners With Increases Or Decreased Sized Ends And D/Ring Type Following Sizes And Numbers Spanners 6-0, 7-8, 9-9-10, 10-11, 11-12, 12-13, 14-15, 16-17, 18-19, 20-21, 20-22, 24-27, 25-28, 30-32, Complete Set Cushion Grip, Pipe Wrench 12 Inch 1 No. 24 Inch 1 No., 12 Adjustable Chrome Plated Wrench, 8 Combination Plier Line Man Plier, 8 Long Nose Plier Length Nose Plier, 9 Crimping Plier Set, 230Mm-, 7 Length Cutting Plier, Hex Key(Ln Key) Set 11Pc Metric (1.5, 2, 2.5, 3, 4, 5,5.5, 6, 8, 10Mm 12Mm), 27Pc-1/2 Sq. Dr 12Pt Socket Set ( Comprising Of ) 20 Pc :- 1/2 Drive 12 Point Sockets: 10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,30,32Mm 6 Pc :- 1/2 Drive Accessories : 2 Pc Extension Bar: 5 And 10(125 And 250Mm) Universal Joint, 1 Pc :- Spark Plug Socket 6 Point 13/16, 1 Pc Sliding T-Bar 10(254Mm); 1 Pc Flip-Drive Rachet., 1/4 Torque Rench, 914Mm , 36 Inch Bolt Cutter (Taparia Make, 12 Hacksaw Frame With 12 No. Spare Blades, Steel Body Retactable Utility Knife With 12 No. Spare Knives, 12H 340Gms Ball Pien Hammer Wooden Handle, 16 900Gms Ball Pien Hammer Wooden Handle, 5 Mtr Measuring Tape, Cold Chesel 7/8 (22Mm), Centre Punch 8Mm (15/16 )X 115Mm(4 1/2 ), Good Quality Multi Meter ( Fluke, Motwane, Meggar Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. 24 Magnetic Torpedo/ Beam Level (3Vails) 300Mm -1 No. & 600Mm -1No., Files Flat/Round Type 8-12 Inch Long, Srew Driver Set Comprising Of 12 No.S Long Shank Having Star/Flat Type Tips With Heavy Duty Tefon Grips , Hv Detectors For All Voltages. (With Fiber Rod Telescopic) , Pliers (Make-Taparia/Stanley) , 11 Kv Hand Gloves ( Make 3M/ Crystal) , Earth Resistivity Tester (0-1000 Ohms) (Make-Motwane/Megger/ Fluke/Markoni) With Auto-Manual Options , Digital Insulation Resistance Tester 5000V (Make-Sonel/Megger/ Fluke/Equivalent) , 10 Feet A Type Ladder , Portable Welding Set , Portable Blue Lamp(Gas) , Portable Blue Lamp (Kerosene) , Insulation Tester And Continuity Tester 2.5 Kv Withvarious Kits (Make- Fluke/ Megger/Equivalent) , Clamp Meter/ Multi Meter ( Fluke, Motwane, Meggar/Meeca Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. , Heavy Duty Pulling & Lifting Machine 5 Mt , Control Relays With 3Oc+1Ef 2 Element Based Digital Of Following Make. , Mit- 114/104 (Er) Make. , Lnt M314a , Schneider , Simens 7Sr , Crompton 14C , Crompton 14Cn , Ashida 131A , Ashida 141 A/B , Ashida Adr241a , Ashida Adr242b , Abb Ref 615 , High Speed Master Relay With 12-63Vdc, 12-220 Vac Coil And 4 No+4Nc Driver Contacts , Battery Bank 30 V,100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type,High Impact Polyprophelene Copolymer Container,Flame Retardant (Exide/Amaron/Shoto/Hbl Make) , Battery Bank 36 V, 150 Ah Ultra Low Maintenance Tubular Battery Bank Compromising Of 3 No. Batteries Each Of 12 Volt (Hbl/Exide/Amaron/Luminous) , Battery Charger 36V, 40/60A With Full Wave Power Diode/Scr Based Recetification And Ripple Filtration. Avr Based Semi Digital With Inbuilt Autotransformer/Variant And Auto Manual Mode Having Digtal Precision Type/ Measuring Instruments, Led Type Indication, Inbuilt Buzzer/ Hoter Alarm During Technical Snags. The Charger Operating Ranges Must Be From 110V To 260 Vac Input Without Attoring Dc Output Through Smps , 7.5 Kva Servo Stablizer Copper Wound With Input Voltage Range 90V To 260V , Distilled Water For Batteries , Power Diodes P-Type/ N-Type ( 40 To 100 A) With Heat Shink , Charger Coil 240/36V Ac , Avr Card Compatile With Existing Chargers , Dc Volt Meter ( 0-60V) , Dimmer/Variac 110V To 260Vac , Power Transformer Equipments , Winding Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes Lv (Make-(Emco/Yoca/Excel) , Oil Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes (Make-(Emco/Yoca/Excel) , Power Oil Conforming To Is:335 Standards , 33 Kv Bushing For 10 Mva Power Transformer , 33 Kv Bushing For 6.3 Mva Power Transformer , 33 Kv Bushing For 5/4/3.15 Mva Power Transformer , 33 Kv Bush Rods For 10 Mva Power Transformer , 33 Kv Bush Rods For 6.3 Mva Power Transformer , 33 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11 Kv Bushing For 10 Mva Power Transformer , 11 Kv Bushing For 6.3 Mva Power Transformer , 11 Kv Bushing For 5/4/3.15 Mva Power Transformer , 11 Kv Bush Rods For 10 Mva Power Transformer , 11 Kv Bush Rods For 6.3 Mva Power Transformer , 11 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11Kv Outdoor Breaker Bushing , Oil Sealing For 33/11Kv Bushing Suitable For 1.0/3.15/2.5/6.3/10Mva , Miscellanous Items , Aluminum Thimble 120 Sqmm 3Mm Thick , Aluminum Thimble 185 Sqmm 3Mm Thick , Aluminum Thimble 240 Sqmm 3Mm Thick , Aluminum Thimble 300 Sqmm 3Mm Thick , Aluminum Thimble 400 Sqmm 3Mm Thick , Aluminum Thimble 630 Sqmm 4Mm Thick , Flexible Insulated Copper Bus/ Braid , Copper Bus Bars 12 Mm Thick , Aluminum Bus Bars 12 Mm Thick , T-Clamps For 0.1 Acsr 400A Presure Di-Cast , T-Clamps For 0.15 Acsr 500A Presure Di-Cast , T-Clamps For 0.20 Acsr 630A Presure Di-Cast , Isolator Pad Clamps 630A Presure Di-Cast , Single Phase Water Pump Motor, Power: 1 Hp , Led Lamp 15 Watt, B-22 Type (Make-Syska/Havells/Wipro/Surya/Ce/Gm) , 50 Watt Led Street Light With Fitting Complete (Make-Syska/Havells/Wipro/Surya/Ce/Gm) Ip-67 , Automatic Voltage Stablizer 5 Kva Copper Wound , 1.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 2.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 4 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 16 annual periodical maintenance Top (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Switch (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Socket (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Combine (Socket/Switch) (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Extension Board With 5 Socket With Fuse And Switch (Make-Anchor/Havells/Crompton/Equivalent) , Pvc Flexible Pipe 1/2 Dia , Ppr Pipe 0.75 Dia , Ppr Pipe 0.5 Dia , Poly Propline Rope-20-30 Mm , Motorized Wood Cutter (58Cc 3.5Hpchain Saw With 22 Inch Cutter Bar Power Full Engine) , Pt Clamps , 33Kv La Clamps 6Mm Thick , Pad Clamps (Aluminuim /Bi Metalic 600A)Presure Di-Cost , Baby Insulators With Nuts & Bolts , 33Kv Ct Clamps ( Threaded And Band Type Cu Made) Tin Coated , Crimping Tool Xple Cable ( Hydraulic Type Upto 120 Sqmm To 630 Sqmm) , Korean Mink Blanket 220X240 Cm 4Kg Weight.Rate Be Quoted Per Kg , Pvc Insulated Copper Bus Bar (50 Mm X 12 Mm) Including Nuts And Bolts 1250A , 11 Kv Vacuum Interrupters (800A/600A) Suitable For Vijai, Er, S&S, Alind, Crompton, Electric Field, Abb, Stelmac, Pascal. Indoor/Outdoor Breakers. , 11 Kv Vacuum Interrupters (800A/600A) Suitable For L&T, Schneider, Sudhir Etc. , 11 Kv Vacuum Interrupters Housing Of Below Mentioned Make. , Vijai And Easun Reyrolle (Per Phase) , Alind (Assembly Upper Set/ Lower Set). , Abb/Electric Field/Crompton/S&S ( Per Phase) , Sudhir And Schneider (Per Phase) , Outdoor Type Pcvcb Upper And Lower Part(Per Phase) , 11 Kv Vcb Equipments Below (Make-Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Voltmeter 11Kv/110V , Ampere Meter , Selector Switch- 16 Amps Vss/Ass , Led Panel Indicators , Push Button With 2No+2Nc , Master Tripping Relay With 4No+4Nc , Hrc Fuse With Base -16 Amps , Connecting Ribs , Auxilary Switch With 8No+8Nc Complete With Bracket And Lever , Auxilary Switch With 12No+12Nc Complete With Bracket Lever , Auxilary Relay -30 A , Trip Circuit Supervision Relay , Bell/Buzzer , Arching Chamber , Tripping Mechanism , Re-Setting Links , Operating Shaft , Shower Contact , Isolating Sockets , Brass Chamber , Lifting Rods , Rollers , Closing Shaft , Contact Bar , Aluminum Chamber , Spring Tension Rod , Gear Assembly , Bmr Mechanism Complete , 33 Kv C&R Panel Equipments (Make Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Bucholz Relay , Winding Temperature Relay , Oil Temperature Relay , Tripping Relay , Alarm Relay , Master Tripping Relay With 4No+4Nc , Tnc Switch 25 Amp. , Energy Meter Of Secure Make With Latest Series Premier 500 Of 11Kv Level And 33Kv Level With 5A Secondary. 11Kv/110V-5A / 33Kv/110V-5A , Electronic Hooter , Ampere Meter With Selector Switch , Voltmeter With Selector Switch , Hrc Fuse With Base , Bell/Buzzer , 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls , 12 Core . , 8 Core , 6 Core , 4 Core , 2 Core , 33 Kv Vcb Equipments (Make : Electricfield/Crompton/Abb/Bhel/Sudhir/Pascal/Beeco Lawrie/Megawin) , 33 Kv Vacuum Interrupter 1250A , 33 Kv Porcelain Post Insulator (Msli 1200+) , Operating Rods , Tripping/Closing Coils , Motor Charging 240, 1Cb, 0.1 Kv , Gasket , Operating Shaft , Mechanism Housing , Gear Assembly , Vacuum/Gas Charging Valve , Input/Output Housing Terminal Pads Din Pail Mounted Type , Xlpe Lt Cable 3.5 Core, Armoured, Fire Resistant Of Sizes , 95 Sq.Mm , 120 Sq.Mm , 185 Sq.Mm , 240 Sq.Mm , 300 Sq.Mm , 400 Sq.Mm , 2Mva/1Mva/630Kva/400Kva/250Kva/100Kva ,33/0.433 Kv, 3-Phase Distribution Transformers Eqiments: , 1600 annual periodical maintenance 4P Acb Drawal Type , Breaking Capacity 50Ka With Enclosure , Mccb ‐ 630 Amps , 36 Ka, 4P With Box Ics=100% Icu At 415 (Ka Rms) , Mccb ‐ 400 Amps , 36 Ka, 4P With Box , Mccb ‐ 250 Amps , 36 Ka, 4P With Box , Mccb ‐ 160 Amps , 36 Ka, 4P With Box , Mccb ‐ 1200 Amps , 36 Ka, 4P With Box , 120 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 240 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 400 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 630 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 33/0.433 Kv Transformer Lv Bushing Suitable For 100Kva To 2 Mva: , 33/0.433 Kv Transformer Lv Bush Rods Suitable For 100Kva To 2 Mva: , Safety Equipments , Safety Helmets Make-3M/Akamgo/ Hilson) , 33Kv Hand Gloves (3M/Crystal/Honeywell/Meeco/Jyot) , Safety Shoes Valcanised Rubber Made (Make-Allen/ Hillson/ Gasoline/Liberty/Acme/Bata/Neosafe/Honetwell) , Safety Belts Shock Absorber Type (Make-3M/Neo) , Safety Glasses (Make-Stanley/ 3M / Allen) , Safety Jackets (Make-Allen/ Hillson/ Gasoline) , Rain Protective Suit Complete- Pant And Jacket Ip-67 Protected , Fire Extingiusher Co₂ Type Of 6.5 Kg Capacity For Control Room , Fire Extingiusher Abc/Dpc Type Of 9 Kg Capacity For Control Room , Refilling Of Empty/Expred Fireextinguishers , Rubber Mat 1Mx2m 19Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
46.
Public Administrative Department #11267040 Price Bid
Tender for Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.In The Existing Trench, Complete As Required. 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Fixing Of Light Class Gi Pipe Of 50 Mm Dia (Nominal) 3 Meters Length Along The Pole For Protection Of Under Ground Cable As Required. , Excavation Of The Cable Trenches In Hard Rock Not Exceeding 1.5 Meters In Width, And Lift Upto 1.5 Meters, Including Getting Out The Excavated Soil And Disposal Of Excavated Soil As Directed Within A Lead Of 50 Meters. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 6 Sqmm , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Un-Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C X 4 Sqmm , Providing And Fixing Stainless Steel Name Plate Of Size 6×8 Sq Inch Made Of 20 Gauge Sheet Including Engraved Name Of Area Representative Duly Painted Along With Ss Clamp Nut Bolt Etc As Required. , Fabrication, Supplying And Fixing Class B Galvanised Single Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipe With Tightening Bolts Complete As Required , Fabrication, Supplying And Fixing Class B Galvanised Double Overhang Arm Bracket Made Out Of 250Mm Long Galvanised Top Tube With Cap And 1000Mm Long 32 Mm Dia Galvanised Pipes With Tightening Bolts Complete As Required. , Providing And Laying In Position M25 Grade Reinforced Cement Concrete Foundation Of Size 450 Mm(L) X 450 Mm Wide And 1000 Mm Deep I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Rewinforcement Of Cold Twisted Bars Of 12 Mm Dia -960Mm Long (Approx.) - 8 Nos.And Reinforcement Of Cold Twisted Bar Of 8 Mm Dia - 1400 Mm (Approx.) - 6 Nos. (With 150 Mm Spacing) As Required With Supplying And Positioning Of 4 Nos Foundation Bolts Of Size 16 Mm Dia And 600 Mm Long, J Type I/C 2 Nos Template Anchor Plates Of Size 225 Mm X 225Mm X 3 Mm And Providing 63 Mm Dwc Hdpe Pipe For Cable Entry & Exit As Required For 5Mtr Pole , Fabrication, Supply & Erection Of 5.0 Mtr Height, Minimum 3 Mm Thick, Bottom Dia Of 130Mm & Top Dia Of 70Mm, Base Plate Of Size 225 X 225 X 12 Mm Thick Flange Mounted Hot Dip Galvanized Octagonal Pole Made From Ht Steel Plate, Window With Flash Cover With Full Vertical Window Cover At Appropriate Height From The Base Plate On Existing Cement Concrete Pedestal As Required. L/C Supplying And Fixing Of 6 Mm Thick Laminated Mounted Sheet Inside The Window And L/C Providing And Welding 3 Nos. Gi Strips 4 Mm Thick Of Suitable Length And Having Suitable Size Tapped Holes As Reqd, Terminal Block Suitable For 25 Sq Mm Conductor - 4 Nos. & Shorting Links On Din Channel L/C Providing And Fixing Din Channel Of Suitable Length, 6 Amp. Spmcb C Curve Characteristics, Earth Stud, Cable Support Clamp Suitable For Upto 4X25 Sqmm Cable. Logo/Name Of Manufacturer Shall Be Either Embossed Or Rivited Plate On The Pole. Galvanization As Per Relevant Is Code Etc As Required , Supply And Fixing Of 32Mm Dia X 1 Meter Long G.I. Pipe (Medium Class) Bracket For Mounting Of Fluorescent/Hpmv/Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape , 2 Nos 25Mm X 6Mm Flat Iron Clamps With Nuts, Bolts And Washer , Painting The Flat Iron With Primer And Finish Paint Etc. As Reqd. , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminum Body (System Lumen Efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminum Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range -5 Deg Centigrade To 50 Deg Centigrade, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-45, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2 , P. F.≥0.95, Ip66,Ik-10, Cri ≥70 , Under Voltage And Over Voltage Protection,Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report , Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 45 Watt
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
47.
Tourism #11266721 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Jul 03, 2026 Contract Value : 5.42 Crore
Government Departments No of Bidders 2
48.
Public Administrative Department #11258216 AOC
Tender for Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole Cap Etc Supplying Of Swaged Steel Tubular Pole As Per Is 2713, Pt. Ii, 1980 For Following Designation And Of Following Dimensions.(Outside Dia & Thickness Are Given In Annexture -1) B) 4 Swg ;5.0 Mtrs; 45 Kg , Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe,, Pole Cap Etc. Erection Of Minipole Of Height 3.25 M To 5.0 M In cement concrete Foundation 0.46 M X 0.46 M X 0.9 M Depth Of 1:3:6 Cement Concrete With Hard Jhama Metal/Stone Chips Including Muffing Of 0.3M X0.3M X 0.3M Painting The Pole With 2 Coats Of Aluminium Paint Over A Coat Red Oxide. , Schedule Of Rates For Earthing Installations.Earthing Installation ... With Pipe Electrode.Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below:(A)By Isi Medium Gi Pipe. , Supply/Fixing Arm Bracket Of 50 Mm Bore Tubular Pipe (M.S.) Of 1. 5 M (5) Length For Fixing On 75/100 Mm Pole Top Including Supply/Fixing 4 Mm Thick M.S. Plate Welded With Bolts, Nuts & Clamps, Etc. As Required With Fabrication Work , Supply/Fixing Of Special Head Type M S Loop Box (3 Mm Thick) With Connecting Bar And Other Accessories Fixed On The Top The Pole As Required And As Per Direction Of Engineer-In-Charge. For 3 Phase Connection. , Supplying Al.Conductor Pvc Insulated And Sheathed Unarmoredcable (1.1Kvgrade, Gloster/Havells/Polycab). 10Sqmm X 2Core , Supply And Drawing Of 7/14 Swg Galvanised Stranded Wire For Drawing Unarmored Cable (Supply Of Cable Is Not Included In The Scope) By Catenary System Of Wiring With 3Nos. Reel Insulator Per Mtr. And Binding With Binding Wires Etc,As Reqd. For Drawing , Supplying A
Contract Date: Jun 09, 2026 Contract Value : 1.84 Lakh
Local Bodies No of Bidders 3
West Bengal View Result →
49.
Rural Development #11250007 AOC
Tender for Providing, Erecting And Supplying Various Different Electric Material For 1 Year @Gr Anchayat Kadamwakwasti , Electric Material This Rate Please Mentioned Include Gst Invoice Shall Be Prepared With Gst Tax Whatever Applicable On Material Rate Are Mentione With Gst , Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Angle Iron 50X50x6 Mm And 550 Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh -Pl/Bkt , Making Cement Concrete Foundation Including Excavation (60 X 60 X 150) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, (45 X 45 X 45) Cm /45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (Above 6 M To 9 M Poles) , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 6 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 8 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm. Dia With 4.5 X 4.5 X 3.65 Mm Thickness ( 5 + 2 + 2M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 147 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia With 4.5 X 4.5 X 3.65 Mm. Thickness (5 + 2.5 + 2.5 M) Length Respectively And Total 10 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 160 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia. With 4.5 X4.5 X3.65 Mm Thickness (5.60 + 2.7 + 2.7 M) Length Total 11 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 175 Kg.) As Per Specification No. . Oh-Pl/Stp , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting On Tubular Welded Pole With 40 Mm. Dia 1.0 M Long B Grade G.I. Pipe Along With Pole Cap Of 125Mm Dia 600 Mm Long Duly Welded As Per Specification No. Fg-Bkt/Bpc , Supplying, Erecting & Marking Dpmcb 40A To 63A, B- Series (For Lighting) In Provided Distribution Board As Per Specification No. Swswr/Mcb , Supplying And Erecting Insulated D.P. Switch Surface Type/Flush Type 32A 240Vwith Indicator Lamp & Fuse , Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching On & Switching Off Street Light As Per Daily Sunset And Sunrise Respectively , Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm (30 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm (50 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting Suitable For Above 40W To 48W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No Bajaj. Fgodf/Fls2. , Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete As Per Specification Bajaj No Fg Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting Suitable For Above 70W- 75 Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls2 , Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting 100W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 120 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 150 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg Odf/Fls-2 , 2-5-17 Supplying And Erecting Led Flood Light Fitting Of 150W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification Jno. Fg-Bkt/Bpc(2-9-2) , Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘B Class G.I. Pipe 1.2 M In Total Length Complete As Per Specification No. Fg-Bkt/Wb(2-9-3) , Supplying & Laying Pvc Armoured Cable 4Core 6Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 10 Sq Mm 7-1-15 , Supplying & Laying Pvc Armoured Cable 2Core 10 Sq Mm , Supplying & Laying Pvc Armoured Cable 2Core 6 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 16 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 25 Sq Mm , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 70 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 95 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 120 Sq. Mm. Aluminium Conductor With Continuous , Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series (For Lighting) , Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries (For Lighting) , Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete , Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete... , Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block/Provided Box, With Necessary Materials. , Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole , Supplying & Erecting Mains With 2X4 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No: Gma/Bw , Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 , Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , 25 Amp, 32 annual periodical maintenance Three Phase L/T Contactor , Insulation Tape , Water Proof Tape , Cable Joint Kit Upto 25 Sq. Mm Cable , Cable Joint Kit Upto 35Sq. Mm To 95 Sq Mm Cable , Cable Joint Kit Upto 120Sq. Mm To 185 Sq Mm Cable , Cement Street Light Pole Clamp With Nut Bolt , M.S. Street Light Pole Clamp With Nut Bolt , Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes(Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Servicing And Primary Maintenance For Street Light Pole. , Light Poles Painting In Silver Colour , 26W Led Light To 100W Led Light Repairing , Old Pole Shifting, Rework And Foundation Work Per Pole Etc. , Supply &Fixing Of Shakle Hardware With Nut Bolt , Supply And Installation Of Mini Feeder Pillar With Stand , Reinforced Cement Concrete Road Cheasling Charges With Tractor Breaker (1 Hours) , Tree Triming For Overhead Line , Supplying & Erecting Street Light Control Panel Outdoor Type, For Single Phase 2 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 2 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete. , Supplying & Erecting Street Light Control Panel Outdoor Type, For Three Phase 4 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 4 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete , Servicing And Primary Maintenance Of Solar Light Pole 1 Visit In Month Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection, Timer Working Condition And Panel Cleaning , Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 9 W Led Fitting, 12V 18Ah Maintenance Free Lithium Battery, Min. 40 Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esd-Sol-Stl ( With 5 Years Warrantee ) , 4-3-13 Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 12W X 2 Nos. Led Fittings, 12V Min. 100Ah Maintenance Free Lithium Battery, Min. 120Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esdsol-Stl , Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. , Providing & Erecting 7 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No.Oh-Pl/Opl. , Providing & Erecting 9 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 155 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 10 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 175 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 11 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 210 Mm A/F, Top 90 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For Highmast Of The Same Manufacturer With 63A Tpn Mcb Incomer, Single Dial Timer Switch, 45A Tp Contactor For Automatic Switching Of Luminaries, 2 Nos 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Erected In Min. 14 Swg Crca Sheet Box Powder Coated With Supporting Angles, Self-Lock, Gasket And Slanting Top Erected With cement concrete Foundation Complete , Supplying And Erecting 12.5 M (Clear Height) High Mast (Top 150Mm, Bottom- 360Mm) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 6 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Hm (Excluding Luminaries ). , Making Cement Concrete Foundation Including Excavation (60 X 60) Cm X Deep 1/6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, 45 Cm X 45 Cm X 45 Cm /45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (For Above 9 M Poles) , Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Fpmccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation As Per Specification No. Sw-Swr/Mfp , Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14/16 Swg Sheet, Outdoor Type, Single Phase, 240 V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Spn Mcb 63 A Auto/Manual Selector Switch,On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / cement concrete Foundation Complete. , Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials As Per Specification No. Ea-Ep , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 600Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 900 /1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. , 36 Watt Pcb , 36 Watt Driver , 50-60 Watt Pcb , 50-60 Watt Driver , 70 Watt Pcb , 70 Watt Driver , Highmast Repairing 100-150 Watt , Service Wire 4 Sq.Mm Isi Mark 2 Core , Service Wire 6 Sq.Mm Isi Mark 2 Core , Service Wire 10 Sq.Mm Isi Mark 2 Core , Frp Box Of Size 300 X200 X125 Mm 2.7Mm Thickness , 12W Led Bulb , 14W Led Bulb , 18W Led Bulb , 100 W Bulb , 200 W Bulb , 35 annual periodical maintenance Kitkat Fuse , 63 annual periodical maintenance Kitkat Fuse , Servie Reel Pvc , Retrofit T8 Led 18/20 Tube Light , Lamp Holder China Clay , Lamp Holder (Pendent) , 5Am Shocket Armor , 5Am Sawich Armor , Miter Box Singal Phase Pvc 300X150x420 , Miter Box 3Phase Pvc 540X600x200 , Miter Box Coted , 8M Sarfes Box & Pleat , Rsj Pole 9 Mtr , V Cross Arm 22 Kv , Cut Pont Set 22 Kv , Pin Insulater22 Kv , Disc Insulater 22 Kv , Nut Bolt , Conductor 55 Sq Mm Aac , Ht Stay Set , Lt Stay Set , Stay Wire , Gi Wire 8 Swg , Pole Errection , Conductor Errection , V Cros Fixing , Cutpoint Fixing , Mcb Box Metal 3Way , Supply Of Tiranga Pole As Per Sepcifucation 139.7Mm Od Pipe - 3Mtr 114.3Mm Od Pipe 1Mtr - 03 Nos 88.9Mm- Od Pipe - 2 Mtr Total 8 Mtr Pole , Day &Night Motin Sensor Auto On/Off Light Electronics(With Drayvar) , 9 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 6 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 6 Nos. E) Solar Panel Should Be Of 330 Watt --- 6 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , 6 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 4 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 4 Nos. E) Solar Panel Should Be Of 330 Watt --- 4 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , Gst Charges
Contract Date: Jun 08, 2026 Contract Value : 14.78 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
50.
Defence #11244665 Technical Bid
Tender For Maintenance Of E/M Misc Items In The Aor Of Age E/M Under Ge Khumbathang- 1 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity 630 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc.Complete All As Directed By Engr-In-Charge. 2 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity 800 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. Complete All As Directed By Engr-In-Charge. 3 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity1000 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc.Complete All As Directed By Engr-In-Charge. 4 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Of Any Size & Capacity With On Load Changeover Switch 4 Pole 1000 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing Complete Switch All As Directed By Engr-In-Charge. 5 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Of Any Size & Capacity With Off Load Changeover Switch 4 Pole 1000 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing Complete All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Of Any Size & Capacity With On Load Changeover Switch 4 Pole 800 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Of Any Size & Capacity With Off Load Changeover Switch 4 Pole 800 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 630 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 630 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 400 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 400 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 12 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 200 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 13 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 200 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 14 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 100 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 15 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 100 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 16 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 63 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 17 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 63 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 18 M & L For Changing The Locking Arrangement And Refixing The Doors Of Lt Panels By Welding Nut, Bolts And Washer Etc And Prepare The Outer And Inner Surface Of Panel For Painting And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed 19 Disconnecting From Circuit/Bus Bar Lt Panel And Taking Out Cables For Extension Of Loop/Passing Through Pipe Reconnection With Circuit And Tightening Of Connections By Using Suitable Size Of Lugs/Thimbles Complete All As Specified And Directed 20 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 1000 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 21 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 800 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 22 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 630 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 23 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 400 Amps Breaking Capacity 36 Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 24 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 415 Volt , Adjutable Type, 250 Amps Breaking Capacity 36 Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge 25 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 415 Volt , Adjutable Type, 200 Amps Breaking Capacity 36 Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 26 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 125 Amps 16Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 27 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 100 Amps 16Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 28 Supply And Fix Thimble Aluminium Eye Type Suitable For Upto 25 Sqmm Including Necessary Crimping With Crimping Tool Complete All As Specified And Directed. 29 All As Per Item No 28 But Of Size Upto 35 Sqmm . 30 All As Per Item No 28 But Of Size Upto 50 Sqmm. 31 All As Per Item No 28 But Of Size Upto 70 Sqmm. 32 All As Per Item No 28 But Of Size Upto 95 Sqmm. 33 All As Per Item No 28 But Of Size Upto 120 Sqmm. 34 All As Per Item No 28 But Of Size Upto 150 Sqmm. 35 All As Per Item No 28 But Of Size Upto 185 Sqmm. 36 All As Per Item No 28 But Of Size Upto 240 Sqmm. 37 All As Per Item No 28 But Of Size Upto 300 Sqmm. 38 All As Per Item No 28 But Of Size Upto 400 Sqmm. 39 Supply And Fixing In Repair Lt Line Separator Suitable For Three Phase Four Wire Water Proof, Weather Proof, Shock Proof, Resistant To Chemicals , Robust Construction Easy To Install Low Maintenance And Fine Uniform Finish All As Directed By Engr-In-Charge. 40 Excavation In Trenches Not Exc 1.5 M Wide And Not Exc 1.5 M In Depth And Getting It Out For Laying Of Cable / Pole Etc In Hard/Dense Soil 41 Returning, Filling In, Including Spreading, Leveling Watering, And Well Ramming In Layers Not Exc 25 Cm In Hard/Dense Soil All As Directed. 42 Removing Excavated Material N.Exc 50M And Depositing Where Directed At A Level Exc. 1.5 Cm Above The Starting Point All As Directed. 43 Supplying And Laying Double Walled Corrugated Hdpe Pipes Of Size 110 Mm Dia As Per Is 16205 Anti Termite, Anti Rodency And Non Flame Propagation Propety Etc For Protection Of Ht Cables Complete All As Specified And Directed 44 Supply And Laying In Replacement Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Armoured Electric Power Heavy Duty 1100 Volt Grade With Stranded Aluminium Conductor Of Size 120 Sq Mm 3.5 Core Complete All As Specified And Directed By Engr-In-Charge. 45 Supply And Laying In Replacement Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Armoured Electric Power Heavy Duty 1100 Volt Grade With Stranded Aluminium Conductor Of Size 150 Sq Mm 3.5 Core Complete All As Specified And Directed By Engr-In-Charge. 46 M&L For Painting Of Lt/Security Light Steel Tubular Pole Upto 9 Mtr Length Incl Ms Clamp , Bracket, Cross Arms And Metallic Junction Boxe With Two Coat Of Alumnium Paint After Preparation Of Old Painted Surface And Applying Metallic Primer , Providing 03 Nos Alternative Strip Of 30 Cm Wide With Black And Yellow Super Quality Enamel Paint Above Embedded Level And Writing Pole Nos With 02 Inch Wide Letter Complete All As Specified And Directed 47 M&L For Painting Of Steel Tubular Pole Upto 11 Mtr Length Incl Ms Clamp , Bracket, Cross Arms With Two Coat Of Alumnium Paint After Preparation Of Old Painted Surface And Applying Metallic Primer , Providing 03 Nos Alternative Strip Of 30 Cm Wide With Black And Yellow Super Quality Enamel Paint Above Embedded Level And Writing Pole Nos With 02 Inch Wide Letter Complete All As Specified And Directed. 48 Supply Installing, Testing And Commissioning Of Lt Panel Of Size 1.8 X 1.5 X 0.5 Mtr Outdoor Kiosk Type Factory Made Of Angle Iron 65Mmx 65Mmx 6Mm On All Side Welded To 3.15 Mm Thick Crca Sheet Steel For Outer Compartment And 2.0 Mm Thick For Inner Compartment With Openable Shutteron Both Sides ( Front And Rear) , Having Locking Arrangement Totally Enclosed Weather Proof Outdoor Spray Painted Internally And Externally With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Suitable For 440 Volts, 3 Phase, 4 Wire, 50 Hz With Aluminium Bas Bar Of Capacity 800 Amps Ac Supply, Electrically Connected As Per Norms And Fitted With Following Accessories All As Specified And Directed By The Engr-In Charge. (Note:- Lt Panel Shall Be Mounted On Pcc 1:2:4 Type B-1 With 20 Mm Graded Stone Aggregate Foundation Block Of Suitable Size Upto 40 Cm Above Ground Level As Directed. The Cost Of The Pcc Block Shall Be Deemed To Be Included In The Unit Rate Quoted For The Item. The Panels Shall Be Of Cpri Approved Note:- Drg Of Panel Shall Got Approved Before Execution At Site. Incommer Incoming Mccb, 415V, 4 Pole, 400 Amps, 36 Ka, Ics =100% Icuindicator Lamp-01 Set (Set Of Three)Voltmeter 0-500 Volt , 415V , 50 Hz ,With Selector Switches -01 Setammeter 0- 500 Amps With Cts, 415V 50 Hz With Selector Switches -01 Setoutgoingmccb, 415V, 4 Pole, 200 Amps, 25 Ka -01 Nomccb 4 Pole 125 Amp, 415V, 36 Ka, 4 Pole , 02 Nos Mccb 4 Pole 63 Amp, 415V, 36 Ka, 4 Pole , 01 Nos Mcb Spn 40 Amps , 230V, 50 Hz - 01 Nos 49 Supply Installing, Testing And Commissioning Of Bus Bar Junction Box Panel Of Size 0.75 X 0.6 X 0.3 Mtr Outdoor Kiosk Type Factory Made Of Angle Iron 65Mmx 65Mmx 6Mm On All Side Welded To 3.15 Mm Thick Crca Sheet Steel For Outer Compartment And 2.0 Mm Thick For Inner Compartment With Openable Shutteron Both Sides ( Front And Rear) , Having Locking Arrangement Totally Enclosed Weather Proof Outdoor Spray Painted Internally And Externally With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Suitable For 440 Volts, 3 Phase, 4 Wire, 50 Hz With Aluminium Bas Bar Of Capacity 800 Amps Ac Supply, Electrically Connected As Per Norms And Fitted With Following Accessories All As Specified And Directed By The Engr-In Charge. (Note:- Bus Bar Junction Box Shall Be Mounted On Pcc 1:2:4 Type B-1 With 20 Mm Graded Stone Aggregate Foundation Block Of Suitable Size Upto 40 Cm Above Ground Level As Directed. The Cost Of The Pcc Block Shall Be Deemed To Be Included In The Unit Rate Quoted For The Item. Note:- Drg Of Bus Bar Junction Box Panel Shall Got Approved Before Execution At Site. Incommer/Out Goingincoming Mccb, 415V, 4 Pole, 400 Amps, 36 Ka, Ics =100% Icu -01 Nosindicator Lamp-01 Set (Set Of Three) E Tc
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu And Kashmir View Result →
TenderDetail
Loading tenders