View Bid Results For Erection Of Structure Tenders

We found 5202 Bid Results related to erection of structure tenders. You can find Contractor details who won erection of structure tenders along with contract details in Bid awards announcements section.

Filters
Stage
3149
1217
836
Tender Publishing Platform
357
4845
State / UT
37
1315
976
708
395
264
240
199
188
157
109
82
81
68
66
56
47
46
40
35
23
19
19
11
10
7
6
6
6
5
4
3
3
3
2
1
1
1
Contract Value
2211
1161
1297
519
Publish Date
32
1
0
0
0
Sector
31
2360
449
403
388
308
229
179
141
121
95
93
62
52
44
35
33
29
26
24
19
18
15
15
15
12
11
8
6
5
5
2
Ownership
7
2571
1888
426
217
86
9
5
Within keyword
Active filters:
Showing 1–50 of 5202 tenders matching your filters
2.
Power #11480986 Price Bid
Tender for Replacement Of Damage/Defective Vcb Of 33 Kv Hospital Bay At 132 Kv Sub-Station, Bahraich, Providing And Fixing Of Various Material At 220 Kv Sub-Station, Bahraich & 132 Kv Sub-Station, Bhinga Under Etd Bahraich , Dismantling Of Damaged 36 Kv Vcb From 33 Kv Bay Including Opening Of Both Side Jumpers, Opening Of Cable Termination And Earthing Strips. This Work Also Includes Other Associated Work To Complete The Job Satisfactorily. , Safe Shifting Of Damaged 36 Kv Vcb And Other Materials From Work Site To Open Store A Directed By Engineer. , Modification Of Existing Foundation And Refabricating Of Auxiliary Structure Of Damaged 33 Kv Breaker As Per The Suitability Of New Breaker To Be Installed At 33 Kv Feeder. This Work Included Cutting And Bending Of Exiting Auxiliary Structure. Welding, Punching Holes In The Existing/ New Galvanized Angle Such That Modified Structure Should Be Able To Support The New Breaker. , Erection Of New 36 Kv Vcb On Existing Breaker Structure In Safe Way Including Modification Of Existing Structure And All Associated Work To Complete The Job Satisfactorily. , Jumpering Of New 36 Kv Vcb On Both Sides With 06 Nos. Panther Jumper If Requirement All Associated Work To Complete The Job Satisfactorily. , Cable Termination Of Vcb Including Ferrules, Cable Glands And All Associated Work To Complete The Job Along With Men, miscellaneous Consumable, T&P, Lug, Cable Gland, Ferrule Etc. Will Be Provided By Contractor At His Own Construction , Re-Earthing Of 36 Kv Circuit Breaker By Cutting Bending & Welding Of 50X6 Mm Ms Flat To Existing Riser Work Includes Checking Of Existing Nser Connectivity To Earthmate Painting Of Existing Riser Earth Flat With One Coat Of Red Oxide And Two Coat Of Black/Bus Green Enamel Paint Of Standard Make After Cleaning Of Strip/Angle For Rust/Dust Fire Including Cost Of Men Material And T&P As Per Direction Of Supervising Engineer To Complete The Job Satisfactorily , Repairing Of Operating Mechanism Of Old Vcb Of Bay Including Travel Measurement Of Moving Rod, Checking Of C.B. Contact Continuity, Dismantling Of Tie Rod Assembly, Cleaning & Greasing Of Its All Roller Pins And Its Re-Assembly. Rectification Of Problem In Electrical Circuit Including Aux. Contact Block, Checking Of Auto Operation Of Spring Charging Motor, Setting Of Limit Switches, Measurement Of Contact Resistance Of All The Poles Using Contact Resistance Meter. Measurement Of Closing & Tripping Time Of All The Poles With Help Of Digital Time Measurement Equipment, Checking Of Healthiness Of The Vacuum Interrupter By Using Vacuum Interrupter Tester And Finally Checking Of Opening & Closing Operation Of The Circuit Breaker On Remote And Local. , Safe Loading, Carriage And Unloading Of 33 Kv Vcb By Truck/Private Vehicle & Hydra From 132 Kv Sub-Station, Bhinga Approx. 40 Km. , Providing And Fixing Of 33 Kv Vcb Vaccume Interepter Suitable For 1600 Amp. (Siemens Make Vcb) As Per Sample At 132 Kv Sub-Station, Bhinga , Providing And Fixing Of Abb Motor Gear Set Of 33 Kv Vcb As Per Sample At 220 Kv Sub-Station, Bahraich
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 57.00 Lakh
Government Departments No of Bidders 1
4.
New and Renewable Energy #11476051 AOC
Bids Are Invited For Annual Mechanical Maintenance Jobs Of Mill Neutral Thickener Tailings And Disposal Area Selective Replacement Of Worn Out Steel Structures Fabrication , Selective Replacement Of Worn Out Steel Structures Erection , Selective Replacement Of Worn Out Steel Structures Dismantling , Selective Replacement Of Worn Out Chequerred Plates Or Ms Gratings Fabrication , Selective Replacement Of Worn Out Chequerred Plates Or Ms Gratings Erection , Selective Replacement Of Worn Out Chequerred Plates Or Ms Gratings Dismantling , Replacement Including Dismantling Erection And Alignment Of Coneyor Pulleys ,Fittings Of Idlers And Rollers , Replacement And Erection Of Feed Bend Conical Seal And Flat Seal Wiper Of , Repair Or Replacement Of Conveyor Belt , Dismantling Of Gear Box Trommel Screens Torsion Shaft Feed Anddischarge Sleeve Launder Hydrocyclone Underflow And Overflow Valves Coupling Mill Liners And Girth , Erection Of Gear Box Trommel Screens Torsion Shaft Feed Anddischarge Sleeve Launder Hydrocyclone Underflow And Overflow Valves Coupling Mill Liners And Girth , Replacement Of Propeller Shaft , Replacement Of Propeller Blades , Replacement Of Agitator Assemblynt , Fabrication Of Pipe Size 15 Nb To 40 Nb , Erection Of Pipe Size 15 Nb To 40 Nb , Dismantling Of Pipe Size 15 Nb To 40 Nb , Fabrication Of Pipe Size 50 Nb To 80 Nb , Erection Of Pipe Size 50 Nb To 80 Nb , Dismantling Of Pipe Size 50 Nb To 80 Nb , Fabrication Of Pipe Size 100 Nb To 150 Nb , Erection Of Pipe Size 100 Nb To 150 Nb , Dismantling Of Pipe Size 100 Nb To 150 Nb , Fabrication Of Pipe Size Above 150 Nb , Erection Of Pipe Size Above 150 Nb , Dismantling Of Pipe Size Above 150 Nb , Erection Of Jammed Pipe Size Above 150 Nb , Dismantling Of Jammed Pipe Size Above 150 Nb , Mill Feed End Trunion Bearing Or Insert Changing , Mill Discharge End Trunion Bearing Or Insert Changing , Erection Of Liner Fitting In Different Chutes , Dismantling Of Liner Fitting In Different Chutes , Lubrication Of Equipments , Overhauling Or Replacement Of Slurry Pumps Total Quantity : 8501
Contract Date: Ref. Documents Contract Value : 37.43 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Ref. Documents Contract Value : 83.93 Lakh
Government Departments No of Bidders 10
Contract Date: Ref. Documents Contract Value : 59.86 Lakh
Boards / Undertakings / PSU No of Bidders 10
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
21.
Educational and Research Institute #11419410 Technical Bid
Tender for E-Tender Documents For Event Management (Catering Services, Accommodation, Tsr, Infrastructural Support Viz Ground Preparation Etc., Decoration And Other Items) For Opening Ceremony And Organizing Of State School Games , National School Games, Pre-Subroto Cup Cluster & State Level Football Ch Ionship, Jn Hockey Ch Ionship, Id Parade, Rd Parade, Jai Hind Bahini Programmes, Nsg Participation, National Yoga Olympiad, Conducting Coaching C , Sidhu Bhanu Gold Cup, Band Competition, Govt. School Meet, Conducting Refresher Course For Officers And Teachers, & Other Events In Kolkata And Different Districts Within The State Including Other States Of The Country And International Participation. , Erection Of Stage On Iron Structure With Floor Carpet And Flower Decoration, Back Led. 3 Side Open With Railing And Both Side Case Measuring 40 Ft X 30 Ft With Platform 3 ½ Ft Hight , Erection Of Stage On Iron Structure With Floor Carpet And Flower Decoration 3 Side Open With Riling And Both Side Case Measuring 30 Ft X 30 Ft With Platform 2½ Ft Hight , Erection Of Pandal (Hanger / Iron Structure) With Sufficient Hight Completely Rain Proof (Size 160 Ft X 50 Ft) , Two Guest Room Adjacent To The Main Stage With Soft, Table, Chair 15 Ft X 30 Ft , Erection Of Stage On Iron Structure With Floor Carpet And Flower Decoration, 3 Side Open With Riling And Both Side Case Measuring 30 Ft X 30 Ft With Platform 3 ½ Ft Hight , Erection Of Pandal On Iron Structure With Floor Carpet And Table With Cover(3Pc) Chair (30) 3 Side Open Measuring 30 Ft X 30 , Erection Of Pandal (Hanger / Iron Structure) With Sufficient Hight Completely Rain Proof (Size 120 Ft X 50 Ft) , Podium (2 Nos.) With Flower Decoration , Complete Stage Decoration (3 Nos.) , Centre Table 20 Pc With Cover & Flower Basket , Sofa Triple Size , Steel Barricade 100Ft , Vvip Thone Chairs With Centre Table , Vip Chairs With Centre Tables , Fibre Chair , Iron Flag Pole -1 Dais- ( 3 Pc) , Flag Pole With Colour Flags , Saluting Dais 6 Heights X 2 Mts. With Back Side Indian & West Bengal Map With Beautification By Flowers & Flower Tubs , Complete Set Up: Boxing Ring(6.1 M X 6.1 M) On Each Side Within The Rope Per Day. , Overhead Gates , Main Gate At Entrance , Fibre Tables With Cover , Decoration On Both Of Approach Road (100 Ft) , Decoration On Gallery Walls On Both Sides (100 Ft) , Erection Of Overhead Chala At Open Gallery Measuring 160Ft X 50Ft , Erection Of Dining Hall With Table Chair Floor Carpet Measuring 100 Ft X 50 Ft , Flex Fitting Size 10 Ft X 8 Ft (Horizontal) , Flex Fitting Size 3 Ft X 6 Ft (Vertical) , Flex Fitting Size 10 Ft X 25 Ft (Vertical) , Flex Fitting Size 6 Ft X 20 Ft (Vertical) , Complete Set Up: Wrestling Ring(20 Ft X 20 Ft), Height- 40 Inches Per Day. , Flower Tubs , Balloon (All Ground & Entry Point) Decoration At All Grounds, Entries And Exits 100 Ft , Flower Bouquets , Complete Accommodation Set (Mattress/ Toshok, Pillow With Cover And Bed Cover) , Complete Toiletry Kit In Pouch (Toothbrush, Toothpaste, Soap, Body Oil, Comb, Moisturiser, Antiseptic Cream Etc.) , Still Photography , Transportation For Participants By Bus With More Than 50 Seats (Venue/ Different Ground/ Station/ Accommodation Centre Etc.) , Transportation For Participants By Bus With Less Than 50 Seats (Venue/ Different Ground/ Station/ Accommodation Centre Etc.) , Transportation For Officials By Light Vehicles 7 Seater (Venue/ Different Ground/ Station/ Accommodation Centre Etc. , Transportation For Officials By Light Vehicle - 4 Seater (Venue/ Different Ground/ Station/ Accommodation Centre Etc. , Transportation For Officials By Suv Vehicle - 9 Seater (Venue/ Different Ground/ Station/ Accommodation Centre Etc. , Vinyle Board For March Past (1Ft X 2Ft) , Arrangement Of Roller Skating Rink (23 Mm X 46 Mm) Per Day. , Complete Ground Preparation , I-Card With Jacket & Digital Tag , Stand Fan , Tube Light & Metal/ Halogen , Accommodation Of Participants On Sharing Basis (2-4 Heads Per Room) At Kolkata & Districts , Accommodation Of Officials On Twin Sharing Basis At Kolkata & Districts , Arrangement (Accommodation, Food, Transport & Remuneration) For Referees/ Umpires/ Technical Officials For Conducting The Matches , Arrangement For Travel Cost & Remuneration For Organising Officials ,Observers,Seiectors For Conducting The Matches , Arrangement (Accommodation, Food, Transport & Wages) For Grounds Man / Ball Boy , Arrangement Of Shooting Arena For 10M Air Range, 25M And 50M Ranges (8-Lane Ranges) And Should Be Digital Score Board , Instant Digital Colour Certificate Printing (Size: A5 Of 300 Gsm) , Bio- Toilet , Security Services , Designing Mascots , Arrangement For Mascots 3 D Structure (Preparation & Installation) , Plastic Bucket (Medium Size) & Mug , Sataranchi (Cotton Make & Standard Size) , Arrangement Of Fencing Court: 14M (45.93Ft) Long And 2M (6.56 Ft) Wide For 2 Days. , Morning: Tea Biscuits , Breakfast: - Breed With Butter, Banana (2) Boiled Egg (2), Sweet/ Puri, Sabji, Sweet, Boiled Egg /Upma Sambar, Boiled Egg. Banana, Mineral Water , Lunch:- Basmoti Rice, Dal (Changeable) Sabji (Changeable), Veg Fry, Fish/Chicken/Egg, Chatni, Papad, Dohi, Mineral Water , Evening Tiffin: Cake, Paties, Tea/ Chowmin, Tea/ Egg Devil (2), Fruity, Mineral Water , Dinner:- Basmoti Rice, Dal (Changeable) Sabji (Changeable), Veg Fry, Fish/Chicken/Egg, Chatni, Papad, Salad/ Fried Rice, Chicken Kosha/Chili Chicken, Sweet & Salad, Mineral Water , Lunch For Inauguration: Fried Rice & Chicken Kosha, Water Bottle (1/2 Ltr) , Food Packets For Guest, Dignitories & Press & Others , Water 1 Ltr. , Water 500Ml. , Fruit Juice (Tetra Pack 300Ml) , Glucon -D 1 Kg. , Dettol 1 Ltr. , Absorbent Cotton 500 Gm , Bandage 1 Mtr. , First Aid Kit , Ambulance With Medicine, Stretcher And Oxygen Cylinder With Supporting Staffs , Uttorio , Vvip Uttorio , Normal Badge , Vvip Badge , Good Quality Cap With Printed Logo , Good Quality Hat With Printed , Cosco Premium Football For Competition , Net For Goal Post (Best Quality Nylon) , Cosco Football , Gold Medal Embossed With Box , Silver Medal Embossed With Box , Bronze Medal Embossed With Box , Champions Trophy , Runners Up Trophy , 2Nd Runners Up Trophy , Best Player Of The Tournament (Boot Trophy) , Best Goalkeeper (Gloves Trophy) , Man Of The Match - Final , Individual Category Trophy , Highest Scorer (Football Trophy) , Memento , Flag: Digital Printed (Size 4Ft X 6Ft) , Complete Football Kits For Final Team(Both): Jersey, Hose, Socks, Boot, Sin Guard, Abdomen Guard, Gloves For Goalkeepers, Bibs Etc.. , Complete Kit For Delegates, Sed & Dse Officials: Tracksuit (Upper& Lower) With Digital Printing ,T-Shirt & Hat With Printing, Bag, Towel , Complete Kit For Participants, Coach, Manager From Districts/ Schools /Of Contingents : Tracksuit (Upper& Lower) With Digital Printing ,T-Shirts / Jersey-Pant &Cap With Printing, Socks, Canvas Shoes, Towel, Water Bottle , Complete Kit For Council Members & Dignitaries From District Administration: Tracksuit (Upper& Lower) With Digital Printing , T-Shirts & Hat With Printing, Bag, Towel , Complete Kit For Organising Officials: Tracksuit (Upper& Lower) With Digital Printing ,T-Shirt & Hat With Printing, Bag, Towel , Complete Kit For Technical Assistants: Tracksuit (Upper& Lower) With Digital Printing ,T-Shirt & Hat With Printing, Bag, Towel , Complete Kit For Technical Officials: T-Shirt With Printing, Towel, Memento , Complete Kit For Event Assistant: Tracksuit (Upper& Lower) With Digital Printing ,T-Shirt & Hat With Printing, Duffle Bag, Towel , Complete Kit For District Offices Staff: Tracksuit (Upper& Lower) With Digital Printing ,T-Shirt & Hat With Printing, Duffle Bag, Towel , Complete Kit For School Band / Exhibition Match Football Teams : Tracksuit (Upper& Lower) With Digital Printing ,T-Shirt & Cap With Printing, Towel , Complete Kit For Volunteers: T-Shirt & Cap With Printing, Duffle Bag. , Leather Bag , Semi -Leather Bag , Duffle Bag , Procurement Of Walkie-Talkies : 5 Km Range, With Earphones, And All Other Standard Accessories (Preferably Baofeng/ Renmax Made) , Procurement Of Network Printer: Canon Made Image Runner 2060N Or Above , Arrangement For Cultural Programme For Opening Ceremony , Arrangement For Cultural Programme For Closing Ceremony , Arrangement Of Flood Light For Grounds , Led Wall 20 Ft X 20 Ft , Video Camera - High Definition , Drone , Complete Sound System With Jbl Speakers Power Backup, Podium Mike, Electrical Work, , Complete Arrangement Of Sound & Lights For Cultural Programme , Complete Arrangement Of Lights & Fans At Dining Hall , Complete Arrangement Of Wushu Court With An Elevated Platform Measuring 8M X 8M With Height Of 80Cm And Should Be Surrounded By A 2M Wide Safety Cushion And With Digital Score Board For Per Day. , Complete Arrangement Of Kurash Court Of Size 16X 16 Meters & Working Zone Of 10 X 10 Meters With Digital Score Board , Truck Suit - Local Made With Rubber Print Front Logo And Back State Name , Truck Suit -Super Poly - Reputed Brand(Shiv Naresh) & Good Quality With Rubber Print Front Logo And Back State Name , Shorts & Jersey Set - Local Made , Shorts & Jersey Reputed Brand(Track On) & Good Quality Dry Fit Net With Rubber Print Front Logo & Back Number, State Name , Shorts & Vest Good Quality , T-Shirt Reputed Brand & Good Quality With Rubber Print Front Logo And Back State Name , Hose - Nylon , Football Sin Guard , Football Boot , Football Gloves Pu , Football Kit Bag , Football Goal Net , Football Corner Stick (4 Nos.) , Football Referee Flag (2 Nos.) , Hockey Ball (6 Pcs.) Reputed Brand , Hockey Sticks Wooden Laminated Hook Type , Hockey Sticks 6% Carbon 5% Kevlar Aramid 89% G/F , Hockey Goalkeeper Gears (13 Items) , Volleyball (Synthetic/Pu/Leather Pasted) Reputed Brand , Cricket Ball (6 Pcs. Box) Best Quality Reputed Brand , Cricket Bat (Kashmir Willow) Good Quality Reputed Brand , Swimming Costume , Yoga Costume , Table Tennis Ball 40+ 3 Star/2 Star/1 Star (6 Pcs Box) Reputed Brand , Table Tennis Bat (Specification Speed 80 Spin 75 Control 95) Reputed Brand , Digital Weight Machine Reputed Brand , Water Polo Ball Reputed Brand , Height And Weight Measurement Machine , Badminton Shuttle Cock Feather (10 Pcs) Reputed Brand , Badminton Racket Reputed Brand , Badminton Net , White Canvas Shoe Reputed Brand , White Socks , Volleyball Net , Kho-Kho / Kabaddi Mat 35 Mm Stag Made Standard Size , Kho-Kho / Kabaddi Mat 25 Mm Stag Made Standard Size , Kho-Kho Mat Shoe , Magnesium Carbonate Powder For Gymnastics , Good Quality Blazer In Different Size , Luggage Bag 55Cm , Towel(50Cm X 100Cm) , Water Bottle 1 Lit.(Milton/Cello) , Umbrella , Raincoat(Upper & Lower) (Reputed Brand) , Raincoat(Women)(Reputed Brand) , Steel Almirah With Loker Facility , Garbage Pack(Big Size) , Garbage Bin(Big Size) , Shoulder Kit Bag , Shoe(Gold Star) , Judo Mattress (Size 14M X 14M) Rate Per Day Basis Including Carrying & Fitting Charges & Digital Score Board. , Kabaddi Mattress (Size 30 Mm Thikness & 13M X 10M) Rate Per Day Basis Including Carrying & Fitting Charges. , Taekwondo Mat ( Size 12M X 12M)Rate Per Day Basis Including Carrying & Fitting Charges & Digital Score Board. , Archery Equipments (Target, Finger Tab, Bow Stand Minimum Eight Set Per Day) , Chess Board, Chess Pieces And Chess Clock( 100 Sets Per Day Basis Rent) , Cctv Setup (8 No.) With Moniotor Per Day , Gymnastics Apparatus (Floor Exercise, Pommel Horse,Still Rings, Vault, Parallel Bars, Horizontal Bar, Uneven Bar, Beam) Rate Per Day Basis Including Carrying & Fitting Charges. , Remote And On Site Tsr (Technical Support & Resources) Services, Including: Technical Documentation, Score Sheets,Score Slips, Live Score Display System Support, Event Operation Assistance,Technical Coordination & Real Time Troubleshooting And Operational Support For Officials & Organizers Per Day. , End To End Remote Support For Sports Events Including Documentations & Managements And Many Other Supports. , The Scoring System Of Yoga- Registration For Athletes, Prined Score Sheet For Judges, Real-Time Judgement Moduler As Per Sgfi Guidelines, Score Monitoring System By A Chief Judge, Live Showing Of The Score In The Display, Qr Code Scanning System For Showming Scores, Printed Results Of The Events According To Norms & One-Time Travelling Cost (Up & Down).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
West Bengal View Result →
22.
Power #11419246 AOC
Tender for (A) Supply Part-11/.4 Kv 400 Kva Distribution Sub Station , 11/.4 Kv 400Kva Dtr (Rec Sep. Ord 11/1976 , providing St Pole Pole 9 Mtr. Long W/L 220Kgs , Muff For Steel Tubular Pole With Concrete Filling , X-Arm: [Channel Iron (100X50x5 Mm), Length : 2800 Mm X 2 Nos] For Incomer Line , Ms A.I.(50X50x6 Mm), Length: 2800 Mm X(1 Nos For Las ) , X-Arm: [Channel Iron (75X40x5 Mm), Length : 2800 Mm X 4 Nos] For Supporting Do Fuse Unit & Go Switch , X-Arm: [Channel Iron (100X50x6 Mm), Length : 2800 Mm X 2 Nos] For Transformer Bed , X-Arm [Channel Iron (100X50x6 Mm), Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer] , Ms A.I.(50X50x6 Mm), Length: (2800 Mm) X 2 No. , Ms Angle Iron (35X35x5 Mm), Length : 460 Mm X 2 Nos , Ms A.I.(50X50x6 Mm), Length: (950 Mm) X 2 Nos. Of Bed Knee Bracing , Ms Angle Iron (50X50x6 Mm), Length : (2800 Mm) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.I. Wire For Earthing , Ms Angle Iron (50X50x6 Mm), Length : (450 Mm)X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O. Switch Handle Supporting: [C.I. (75X40x6mm), Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O Ab Switch Unit (11Kv,400,663Ka) Tripple Pole O/D Type , D.O Fuse Unit , Surge Arrester, 9 Kv Station Class , Discs Insulator Sets (Comp. 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) I/C Dead End Clamps Etc.) , Stay Set Complete , Stay Wire (7/3.15Mm)( 10 Kg Per Stay Set) , Pipe Earthing With Gi,Charcoal & Salt , providing Lt Distribution Panel With Acb (630 A, 50 Ka, 4P,1 No.) & Sfu (100 A 6 No. Rewireble) For 400Kva Trf. As Per Specification , Half Clamp (M.S. Flat 50X6) , Full Clamps (M.S. Flat 50X6) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Aluminium Thimbles 300 Mm Sq. , Copper Thimble 95 Mm Sq. , Danger Plate , Barbed Wire (Rec Sp F 3/1981) , Lt Cable 3-1/2 Core-400 Mm Sq.For Incomer , Lt Cable 3-1/2 Core-185Mm Sq.X6 O/G , Alluminium Paint , Prov.Acsr, 6/1/3.35 Mm , Chain Link Fencing , Angle Iron, Gate Etc. For Transfromer Fencing , providing Transformer Bed Plinth For 1X400kva S/Stn Structure Complete With cement concrete 1:6:12 R.R. Massonery & Plastering Etc. A/W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. , Lt Switched Capacitors 50 Kvar For 400 Kva T/F , Hp Monochrome Laser Printer (A4) Hp Laser 108A With Prints Up To 20 Ppm, 64 Mb Ram 600X600 Dpi Print Resolution 150 Sheets Paper Tray Caapcity Usb 2.0 Port -One Year Warranty , (A) Erection Part-11/.4 Kv 400 Kva Distribution Sub Station , 11/.4 Kv 400Kva Dtr (Rec Sep. Ord 11/1976 , providing St Pole Pole 9 Mtr. Long W/L 220Kgs , Muff For Steel Tubular Pole With Concrete Filling , X-Arm: [Channel Iron (100X50x5 Mm), Length : 2800 Mm X 2 Nos] For Incomer Line , Ms A.I.(50X50x6 Mm), Length: 2800 Mm X(1 Nos For Las ) , X-Arm: [Channel Iron (75X40x5 Mm), Length : 2800 Mm X 4 Nos] For Supporting Do Fuse Unit & Go Switch , X-Arm: [Channel Iron (100X50x6 Mm), Length : 2800 Mm X 2 Nos] For Transformer Bed , X-Arm [Channel Iron (100X50x6 Mm), Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer] , Ms A.I.(50X50x6 Mm), Length: (2800 Mm) X 2 No. , Ms Angle Iron (35X35x5 Mm), Length : 460 Mm X 2 Nos , Ms A.I.(50X50x6 Mm), Length: (950 Mm) X 2 Nos. Of Bed Knee Bracing , Ms Angle Iron (50X50x6 Mm), Length : (2800 Mm) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.I. Wire For Earthing , Ms Angle Iron (50X50x6 Mm), Length : (450 Mm)X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O. Switch Handle Supporting: [C.I. (75X40x6mm), Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O Ab Switch Unit (11Kv,400,663Ka) Tripple Pole O/D Type , D.O Fuse Unit , Surge Arrester, 9 Kv Station Class , Discs Insulator Sets (Comp. 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) I/C Dead End Clamps Etc.) , Stay Set Complete , Stay Wire (7/3.15Mm)( 10 Kg Per Stay Set) , Pipe Earthing With Gi,Charcoal & Salt , providing Lt Distribution Panel With Acb (630 A, 50 Ka, 4P,1 No.) & Sfu (100 A 6 No. Rewireble) For 400Kva Trf. As Per Specification , Half Clamp (M.S. Flat 50X6) , Full Clamps (M.S. Flat 50X6) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Aluminium Thimbles 300 Mm Sq. , Copper Thimble 95 Mm Sq. , Danger Plate , Barbed Wire (Rec Sp F 3/1981) , Lt Cable 3-1/2 Core-400 Mm Sq.For Incomer , Lt Cable 3-1/2 Core-185Mm Sq.X6 O/G , Alluminium Paint , Prov.Acsr, 6/1/3.35 Mm , Chain Link Fencing , Angle Iron, Gate Etc. For Transfromer Fencing , providing Transformer Bed Plinth For 1X400kva S/Stn Structure Complete With cement concrete 1:6:12 R.R. Massonery & Plastering Etc. A/W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. , Lt Switched Capacitors 50 Kvar For 400 Kva T/F , Hp Monochrome Laser Printer (A4) Hp Laser 108A With Prints Up To 20 Ppm, 64 Mb Ram 600X600 Dpi Print Resolution 150 Sheets Paper Tray Caapcity Usb 2.0 Port -One Year Warranty , (B) Supply Part-Ct/Pt Unit 400 Kva Trf. (1 Nos.) , providing 11Kv Ct-Pt Unit Ct/Pt Combined Unit 11 Kv /110V 50/5 A , Prov, Energy Meter (3 Phase, 4 Wire) Ht Ct Type For Above , Pvc Multistrand 2.5 Mm Sq. Copper Wire , 1 Inch Dia Gi Pipe For Concealin , Bend Joints /Elbow , X-Arm: [Channel Iron (75X40x6 Mm), Length : 2800 Mm X 2 Nos] For Supporting Main Channel For Ct-Pt Unit , Ms Angle Iron (50X50x5 Mm), Length : 2800Mmx 4 Nos. , Ms Angle Iron (35X35x5 Mm), Length : 2800Mmx 2 Nos. , Half Clamp (Ms Flat 50X6 Mm) , Full Clamp (Ms Flat 50X6 Mm) , Nut & Bolts Off Size , Aluminium Thimble , Copper Thimble , (B) Erection Part-Ct/Pt Unit 400 Kva Trf. (1 Nos.) , providing 11Kv Ct-Pt Unit Ct/Pt Combined Unit 11 Kv /110V 50/5 A , Prov, Energy Meter (3 Phase, 4 Wire) Ht Ct Type For Above , Pvc Multistrand 2.5 Mm Sq. Copper Wire , 1 Inch Dia Gi Pipe For Concealin , Bend Joints /Elbow , X-Arm: [Channel Iron (75X40x6 Mm), Length : 2800 Mm X 2 Nos] For Supporting Main Channel For Ct-Pt Unit , Ms Angle Iron (50X50x5 Mm), Length : 2800Mmx 4 Nos. , Ms Angle Iron (35X35x5 Mm), Length : 2800Mmx 2 Nos. , Half Clamp (Ms Flat 50X6 Mm) , Full Clamp (Ms Flat 50X6 Mm) , Nut & Bolts Off Size , Aluminium Thimble , Copper Thimble , (C) Supply Part-New Ht Line (2.43 Kms. With Acsr 6/1/3.35 Mm Sq. On Steel Poles , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 11 Mtr. Long W/L 227 Kgs/M2 (With Ruling Span 90M, 8 No. Run Through And 3 No. Double Pole Dead End Structure , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole (2000Mm Long) With Concrete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length 1270 Mm (I/C Tolerence Of 100Mm Either Side) X2 Structure( Run Through Structure (Formation Tringle) , Angle Iron (50X50x5 Mm), Length (2X750) Mm X 1 Structures (Run Through Structure (Formation Tringle) , Pole Top Bracket [Msci:100X50x6mm-100Mm] , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure (Run Through Structure (Formation Tringle) , Belt Set - Ms Angle Iron: 50X50x6, Length [1800 Mm X 2 No.]For Dead End Structures , X-Bracing Set - Ms Angle Iron: 50X50x6, Length [2125 Mm X2 No.] For Dead End Structures , X-Arm(Horizental) - Ms C. Iron: 50X50x6, Length [2340 Mm X2 No.]For Dead End Structures , Discs Insulator Sets On Dead End Structures (Comprising 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) Including Dead End Clamps Etc.) X (3 No. Conductors) X (2 No. Sides)For Dead End Structures , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure For Dead End Structures , Stay Set Complete In All Respect I/C Clamp ( Single Pole-1No. , /D. Pole Structures-4Nos.) , Stay Wire (7/3.15 Mm) (9.0 Kg Per Stay Set) , G.I. Wire , Eye Hook For Earth Wire , Earth Wire Clamp , Ht Earthing Set Complete (Rec construction Standared J-1) , Half Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Full Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Danger Plate (250X200x1.6 Mm) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Barbed Wire (Rec Sp F 3/1981) , G.O Ab Switch Unit (11Kv,630 A,25Ka) , D.O Fuse Unit , M.S. C.I. 2400 Mm For Road Crossing (75X40x6mm) , Alluminium Paint , (C) Erection Part-New Ht Line (2.43 Kms. With Acsr 6/1/3.35 Mm Sq. On Steel Poles , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 11 Mtr. Long W/L 227 Kgs/M2 (With Ruling Span 90M, 8 No. Run Through And 3 No. Double Pole Dead End Structure , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole (2000Mm Long) With Concrete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length 1270 Mm (I/C Tolerence Of 100Mm Either Side) X2 Structure( Run Through Structure (Formation Tringle) , Angle Iron (50X50x5 Mm), Length (2X750) Mm X 1 Structures (Run Through Structure (Formation Tringle) , Pole Top Bracket [Msci:100X50x6mm-100Mm] , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure (Run Through Structure (Formation Tringle) , Belt Set - Ms Angle Iron: 50X50x6, Length [1800 Mm X 2 No.]For Dead End Structures , X-Bracing Set - Ms Angle Iron: 50X50x6, Length [2125 Mm X2 No.] For Dead End Structures , X-Arm(Horizental) - Ms C. Iron: 50X50x6, Length [2340 Mm X2 No.]For Dead End Structures , Discs Insulator Sets On Dead End Structures (Comprising 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) Including Dead End Clamps Etc.) X (3 No. Conductors) X (2 No. Sides)For Dead End Structures , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure For Dead End Structures , Stay Set Complete In All Respect I/C Clamp ( Single Pole-1No. , /D. Pole Structures-4Nos.) , Stay Wire (7/3.15 Mm) (9.0 Kg Per Stay Set) , G.I. Wire , Eye Hook For Earth Wire , Earth Wire Clamp , Ht Earthing Set Complete (Rec construction Standared J-1) , Half Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Full Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Danger Plate (250X200x1.6 Mm) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Barbed Wire (Rec Sp F 3/1981) , G.O Ab Switch Unit (11Kv,630 A,25Ka) , D.O Fuse Unit , M.S. C.I. 2400 Mm For Road Crossing (75X40x6mm) , Alluminium Paint , (D) Supply Part-Three Phase Lt Line With Aaac 6/1/3.35 Mm Sq. On Steel Poles(0.830 Km) 3-Phase 4 Wire Double Circuit Line , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole , Shackle Insulators (16Kn) (Recd-3/761)(Iss No 1445/1977) , D-Iron (U-Clamp) (Recd-4/79)(Iss No 7935/1975) , Lt Saty Set Complete Rec No 31/1983 , Stay Wire (7/3.15 Mm) (8.0 Kg Per Stay Set) , providing Full Clamp , Earthing Set , G.I.Wire No 8 Swg Earth Wire 1.03Km (Sep.G-2/72) For Suporting Cable , M.S.Nuts & Bolt Off Sizes , C.I. 75X40x6mm (Length 2400X2 Mm) For Centilever Double Circuit Line , Aluminium Paint , (D) Erection Part-Three Phase Lt Line With Aaac 6/1/3.35 Mm Sq. On Steel Poles(0.830 Km) 3-Phase 4 Wire Double Circuit Line , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole , Shackle Insulators (16Kn) (Recd-3/761)(Iss No 1445/1977) , D-Iron (U-Clamp) (Recd-4/79)(Iss No 7935/1975) , Lt Saty Set Complete Rec No 31/1983 , Stay Wire (7/3.15 Mm) (8.0 Kg Per Stay Set) , providing Full Clamp , Earthing Set , G.I.Wire No 8 Swg Earth Wire 1.03Km (Sep.G-2/72) For Suporting Cable , M.S.Nuts & Bolt Off Sizes , C.I. 75X40x6mm (Length 2400X2 Mm) For Centilever Double Circuit Line , Aluminium Paint
Contract Date: Jun 30, 2026 Contract Value : 37.28 Lakh
Government Departments No of Bidders 7
Himachal Pradesh View Result →
24.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : 51.40 Lakh
Government Departments No of Bidders 1
26.
Power #11405691 Technical Bid
Tender for Carriage Of Following Material From Store Center Or From Any Other Place To The Respective Site Of Work Distence Up To 75 Km Through The Kachha Pacca Road Including The Work Of Its Loading & Unloading At The Respective Ends Also Including The Work Of Its Dragging Etc. And Also Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. , 11 Kv Fuse Set , Dropper Channel , Abc Cable (3*120+1*95+1*16)Mm^2 , Lt Ab Cable 1*400 Mm^2 , 250 Kva 11/0.4 Kv T/F New , Supply & Erection Of Following Material As Per Uppcl/Dvvnl/ Respo Norms And Standard/Related Is (Note: All Petty Item Required For Proper Completion Of Work Will Be By Provided By The Contractor Free Of Cost.) , Copper L-Piece , I Hook With Clamp , Lug 120^2 , Dead End Clamp , Suspension Clamp , Distribution Box 3 Phase , Distribution Box Clamp , Lt Protection Pannel With 03 Nos Circuit Stud Type Tailless Unit Along With Busbar For 250 Kva Dt. , Lug 400 Mm^2 , Piercing Connector , Nut Bolt , Erection Of Following Material Including The Work Of Complete H.T. Fittings As Per Respo Manual And As Per Direction Of Engineer Incharge Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. (With Proper Earthing.) , Laying & Erection Of Ab Cable (3*120+1*95+1*16) Mm2 As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carries Etc. Required For Proper Completion Of Work. , Laying & Erection Of Ab Cable (1*400) Mm2 As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carries Etc. Required For Proper Completion Of Work. , 11 Kv Fuse Set , Dropper Channel , Chemical Earthing For 250 Kva T/F For Neutral & Body As Per Respo Norms (All The Material For Earthing Will Be Provided By The Contractor) , Deep Pipe Earthing Of T/F Neutral As Per Standard Specifications & As Per Respo Norms (All The Material For Earthing Will Be Provided By The Contractor) , Mounting Of 250 Kva T/F On The Double Pole / Plinth Structure And Connection Thereof As Per Respo Norms & As Per Direction Of Engineer Incharge Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. , Construction Of Plinth Suitable For 250 Kva T/F With Material (Sand, Bricks, Cement) & T&P Labour As Per Respo Manual. All Meterial Cement, Sand , Blast Stone Will Be Provided By The Contractor. , Fencing Of T/F Plinth Including Material Labour & T&P As Per Respo Manual. , Dismantling Of Existing Line/ T/F And Removal Of All Accessories & Fittings From Poles, Re-Rolling Of Conductor And Proper Stacking And Cartage Of Dismantled Conductor & Accessories From Site Of Work To Dvvnl, Store.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
27.
Power #11405682 Technical Bid
Tender for Carriage Of Following Material From Store Center Or From Any Other Place To The Respective Site Of Work Distence Up To 75 Km Through The Kachha Pacca Road Including The Work Of Its Loading & Unloading At The Respective Ends Also Including The Work Of Its Dragging Etc. And Also Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. , St Pole 11 Mtr. Long , Plain Cement Concrete Pole 8.5 Mtr. Long , Ms Channel Dropper , Base Channel , Ms Channel Top , 11 Kv Disc Insulator , 11 Kv Disc Fitting , T-Off Channel , T-Off Channel Clamp , 11 Kv Pin Insulator , 11 Kv Pin With Nut , Stay Complete , Acsr Weasel Conductor , Dp Clamp , Dp Clamp St Pole For Shackle Insulator , 11 Kv Fuse Set , Cross Arm , Cross Arm Holding Clamp , 11 Kv F-Clamp , Abc Cable (3*95+1*70+1*16)Mm^2 , Abc Cable (3*120+1*95+1*16)Mm^2 , Lt Pvc Cable 3.5*150 Mm^2 , Lt Pvc Cable 1*400 Mm^3 , Earthing Complete , Distribution Box 3 Phase , Distribution Box 3 Phase Clamp , Pg Clamp Weasel To Weasel , New 25 Kva 11/.4 Kv Tranformer , New 63 Kva 11/.4 Kv Tranformer , New 100 Kva 11/.4 Kv Tranformer , New 250 Kva 11/.4 Kv Tranformer , Supply & Erection Of Following Material As Per Uppcl/Dvvnl/ Respo Norms And Standard/Related Is (Note: All Petty Item Required For Proper Completion Of Work Will Be By Provided By The Contractor Free Of Cost.) , Stone Pad , Copper L Piece , I Hook , I Hook Clamp , Lt Fuse Set Protection Unit , Lug 150 Mm^2 , Dead End Clamp , Suspension Clamp , Piercing Connector , Barbed Wire , No. Plate , Nut & Bolt , Danger Board , Red Oxide Paint , All. Paint , Tailless Unit 400 annual periodical maintenance , All Lug 400 Sqmm , Lt Shakle Insulator , Lt Shakle Strip With N&B , Erection Of Following Material Including The Work Of Complete H.T. Fittings As Per Respo Manual And As Per Direction Of Engineer Incharge Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. (With Proper Earthing.) , Erection Of Plain Cement Concrete Pole 8.5 Mtr Long Including The Work Of Complete H.T. Fittings As Per Respo Manual And As Per Direction Of Engineer Incharge Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. , Grouting Of Plain Cement Concrete Pole 8.5 Mtr Long As Per Respo Norms ( Cement, Sand , Blast Stone With The Ration 1:4:8 Will Be Provided By Contractor ) , Erection Of Stp Pole 11 Mtr Long Including The Work Of Complete H.T. Fittings As Per Respo Manual And As Per Direction Of Engineer Incharge Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. , Grouting Of Stp Pole 11 Mtr Long As Per Respo Norms ( Cement, Sand , Blast Stone With The Ration 1:4:8 Will Be Provided By Contractor ) , Fixing Of Stay Rod And Its Erection. Stay Wire Should Be Properly Binded And Tightened As Per Standard Specification. , Grouting Of Stay Set As Per Respo Manual And Also Including The Cost Of All Grouting Material, Labour, T & P Etc. Required For Proper Completion Of Work. , Laying & Erection Of Acsr Weasel Conductor As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carries Etc. Required For Proper Completion Of Work. , Laying & Erection Of1ab Cable (3*95+1*70+1*16)Mm^2 As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carries Etc. Required For Proper Completion Of Work. , Laying & Erection Of Ab Cable (3*120+1*95+1*16)Mm^2 As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carries Etc. Required For Proper Completion Of Work. , Laying & Erection Of Lt Cable (3.5*150) Mm^2 As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carries Etc. Required For Proper Completion Of Work. , Laying & Erection Of Lt Cable (1*400) Mm^2 As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carries Etc. Required For Proper Completion Of Work. , Earthing Complete , Distribution Box 3 Phase , Distribution Box 3 Phase Clamp , Pg Clamp Weasel To Weasel , New 25 Kva 11/.4 Kv Transformer , New 63 Kva 11/.4 Kv Transformer , New 100 Kva 11/.4 Kv Transformer , New 250 Kva 11/.4 Kv Transformer , Chemical Earthing For For Neutral & Body As Per Respo Norms (All The Material For Earthing Will Be Provided By The Contractor) , Deep Pipe Earthing Of T/F Neutral As Per Standard Specifications & As Per Respo Norms (All The Material For Earthing Will Be Provided By The Contractor) , Mounting Of 250 Kva T/F On The Plinth Structure And Connection Thereof As Per Respo Norms & As Per Direction Of Engineer Incharge Including The Cost Of Labour, T & P And Carrier Etc. Required For Proper Completion Of Work. , Construction Of Plinth Suitable For 250 Kva T/F With Material (Sand, Bricks, Cement) & T&P Labour As Per Respo Manual. All Meterial Cement, Sand , Blast Stone Will Be Provided By The Contractor. , Fencing Of T/F Plinth Including Material Labour & T&P As Per Respo Manual.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
28.
Defence #11405404 Technical Bid
Tender for Taking Down Existing Sliding Door With Full Safety Parameter Complete All Specified And As Directed. Note: The Existing Sliding Door Shall Be Carefully Dismantled After Providing All Necessary Safety Arrangements Such As Temporary Supports, Barricading And Warning Signage. Power Supply, If Any, Shall Be Isolated. Door Shutters, Rollers, Guide Rails And Fittings Shall Be Removed Manually Without Causing Damage To Adjoining Structures. Eqpt: Crane Of 18 T With 18M Lenth And Hydra Of 15 M Lenth To Be Present All Throughout Taking Out Of Door And During Re-Erection. All Safety Paramters To Be Followed. , Repairing Of Door Leaf, Straininig By Using Some Mild Steel Stiffeners Complete All Specified And As Directed. Note: The Door Leaf Shall Be Inspected For Deformation And Misalignment. Straightening Shall Be Carried Out Using Mechanical Means. Mild Steel Stiffeners Of Suitable Size Shall Be Welded/Provided At Required Locations To Restore Structural Rigidity. Welding Joints Shall Be Properly Ground Smooth. The Surface Shall Be Cleaned Of Rust, Oil And Loose Scales Prior To Further Treatment. , Replacement Of Bottom Wheel With Shaft, Plate, Bearing, Coating Complete All Specified And As Directed. Make: Jindal/ Sail Note: Damaged Bottom Wheels Shall Be Dismantled Completely. New Bottom Wheel Assemblies Including Shaft, Bearing And Mounting Plate Conforming To Specified Make Shall Be Installed. Bearings Shall Be Properly Aligned And Lubricated. All Metallic Surfaces Shall Be Cleaned And Provided With Protective Coating To Prevent Corrosion. Smooth Rolling And Alignment Shall Be Checked After Installation. , Replacement Of Top Wheel With Shaft Plate, Bearing, Coating Complete All Specified And As Directed. Make: Jindal/ Sail. Note: The Existing Top Wheel Assemblies Shall Be Removed Carefully. New Top Wheel Assemblies With Shaft, Bearing And Mounting Plates Shall Be Fixed In Correct Alignment With The Track. Bearings Shall Be Tested For Free Rotation. Protective Coating Shall Be Applied On Exposed Metal Parts. Proper Vertical And Lateral Alignment Of The Door Shall Be Ensured. , Replacement Of Damaged Puff Panels Complete All Specified And As Directed. Note: The Damaged Puff Panels Shall Be Identified And Carefully Dismantled Without Affecting The Adjoining Panels And Supporting Framework. New Puff Panels Of Matching Thickness, Profile And Insulation Specification Shall Be Supplied And Fixed In Position. Panels Shall Be Properly Aligned, Fastened To The Existing Structure Using Approved Fasteners, And All Joints Shall Be Sealed To Ensure Weather Tightness And Insulation Continuity. The Work Shall Be Completed To Achieve Uniform Appearance And Proper Functionality. , Painting Complete All Specified And As Directed. Note: All Steel Surfaces Shall Be Thoroughly Cleaned By Wire Brushing/Scraping To Remove Rust, Dirt, Grease And Loose Paint. Two Coat Of Approved Anti-Rust Epoxy Primer Shall Be Applied, Followed By One Coat Of Epoxy Paint Of Approved Shade. Painting Shall Be Carried Out After Ensuring Dry And Clean Surfaces, Achieving Uniform Finish. , Re-Erection Of Complete Door Complete All Specified And As Directed Note: The Sliding Door Shall Be Re-Erected On The Guide Rails. Proper Alignment, Plumb And Level Shall Be Ensured. All Fasteners Shall Be Tightened Securely. Trial Runs Shall Be Conducted To Verify Smooth Sliding. Proper Locking And Overall Functionality. , S & Fixing Of Motor System (As Required At Site) Completely Including All Fixing Arrangement Required At Site With Complete Electic Connection ,Testing & Commissioning Etc Complete All As Specified And As Directed.(Make: Siemens/Abb) , Supply And Fix In Replacement Of Chain Wheel Arrangement,Idler,Manual System Suitable For Existing Door Hangar Complete All Specified And As Directed.(Jindal/Sail) , Supply And Fix In Replacement Of Control Panel(Areen),Cable Hooter Cum Flasher,Limi Set Suitable For Door Hangar Complete All Specified And As Directed. Note:- All Boq Items Ser No 01 To 10 Will Be Executed As Per Particulars Specififcations (Ps) As Mentioned In Serial No 14 To 23 At Page No 99 To 104 And Drawing (Attached) As Per Appendix A
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
Arunachal Pradesh View Result →
29.
Power #11376672 Technical Bid
Construction Of 03 Nos. 33 Kv Basani, Sarsawa, Ganeshpur Bays At 220 Kv Sub Station Harahua.- 1 Carriage Of Sub Station Structure By Private Carrier From Efu Naini Prayagraj To 220Kv Sub Station Harahua . Job Includes Loading Of Material By Shifting Of These From Storage Place To Road Side, Safely Loading Of These On Vehicle, Transportation Of Materials From Efu Naini Prayagraj To 220Kv S/S Harhua By Private Vehicle Having One Side Distance Approx. 140Kms. Unloading Of Material From Vehicle Safely And Shifting These To Store And Proper Stacking. (Rate Includes All Labour, T&P Charges And All Associated Work To Perform The Job Satisfactorily) 2 Dismantling Of Pi And Its Structure Including With All Assosiate Work 3 Erection Of Structure Parts Of Main & Auxiliary Structure. The Job Consist To Shifting Of All Material, Structure Parts, Nut Bolts Washers Etc From Store To Work Site, Erection Of Structure As Per Relevant Drawing And Practices. 4 Erection Of Following Equipments As Per Instruction Manual Of Various Equipments Including Its Shifting From The Store To Site Including Other Associated Works To Complete The Job Satisfactory. 5 36 Kv Vcb 6 36 Kv Ct ( Metering ) 7 36 Kv Ct Junction Box (Metering) 8 36 Kv Ct(Protection) 9 36 Kv Ct Junction Box (Protection) 10 36 Kv Lsi 11 36 Kv Lsi Junction Box 12 36 Kv Bsi 13 36 Kv Bsi Junction Box 14 36 Kv Pi 15 33 Kv C&R Panel (Numerical Type) 16 Laying Of D/C 33 Kv Xlpe Power Cable Of Size 3Cx300 Sq.Mm Below 1000Mm From Ground Level Including Excavation Of Trench And Laying Of Cable And Putting Ist Class Bricks On Its 75Mm Edge Along With Cable On Both Side. Filling The Same With Ganga Sand And Then Putting Bricks On 380Mm/Patiya To Cover The Trench And Then Filling With Earth Including Cost Of Bricks Sand Miscellaneous And All Other Associated Work To Complete The Job Satisfactorily. 17 Hoisting Of 33 Kv 3Cx300 Sq.Mm Cable On Pole/Structure Through Gi Pipe Of Size 6\(150Mm) Dia 3 Mtr Long Including Its Jumpering With The Help Of Suitable Size Of Aluminium Lugs. 18 Termination Of Jointing Of Above Power Cable By 3Cx300 Sq.Mm Cable Jointing Kit O/D Type And All Other Associated Works To Complete The Work Satisfactorily As Per Technical Specification 19 Fabrication Fixing And Fitting Of Cable Structure In Shape Of H-Pole, 3 Mtr Long Including Its Grouting With Rcc Of Size 150X150X150Mm In Ratio 1:4:8 Including All Men Material Except Structure/Angle. 20 Jumpering Of Following Bay Equipments With The Help Of Acsr Panther Conductor Including Cutting Bending Clamping With All Other Associated Work From Main Bus To Outgoing Isolators For All Phases. 21 Laying Of Following Sizes Of Control Cable In The Cable Trenches From C&R Panel To Various Type Of Equipments, Junction Boxes In Switch Yard As Per Cable Schedule, Its Clamping/Binding At Every Two Meter Distance With Aluminium Sticks 25X1Mm Size Including Carriage Of Cable Drums From Store To Laying Site And Shifting Back To Store And All Other Associated Work To Complete The Job Satisfactorily As Per Tech. Specification: 22 2X2.5Mm²Control Cable 23 4X2.5Mm²Control Cable 24 6X2.5Mm²Control Cable 25 Termination Of Following Size Control Cable As Laid Above As Per Cable Schedule Including Making Necessary Holes In Glands Plate Of Junction Boxes , Supply And Fixing Of Cable Gland Ferrule Of Appropriate Size And Quantity Respectively For Each Core Of Cable And Its Termination With Crimping Type Lugs Including Lugs, Ferrules & Other Minor Accessories To Complete Job Satisfactory 26 2C X 2.5 Mm² 27 4C X 2.5 Mm² 28 6C X 2.5 Mm² 29 Fabrication Of Electrode By 40 Mm Dia Ms Rods In Length Of 3 Mtr By Making An Edge At One End For Ease In Piercing Below 1200Mm Into The Ground Using Wooden Hammer Completely At All The Junction Points Along With Welding & Painting At Outer Periphery Of Earth Mat As Per Relevant Is (M.S. Round Bar Shall Be Provided By Department). 30 Cutting Straitening Bending Laying Of 75X10 Mm Ms Flat For Earthing Of Main Structures Including Welding With Main Earth Mat Below 500-700 Mm Of Ground Level With Object To Earth Excavation Of Trenches Its Back Filling, Painting With One Coat Of Red Oxide Primer And Two Coats Of Synthetic Enameled Green Colour With All Cost Of Ms Flat, Paint, T&P Required For Completion Of Work. 31 Earthing Of Trench Along With 50X6Mm Ms Flat After Cutting And Welding With Cable Rack And Trench With All Cost Of Ms Flat, Including Painting With One Coat Of Red Oxide Primer And Two Coats Of Synthetic Enameled Paint. 32 Interconnection Of The Earth Mat Laid With The Existing Earth Mat Of The 220 Kv S/S Harahua At 10 Specified Point By Welding As That Complete Earth Mat Acts In Coherent Manner To Provide Proper Earthing Of The Substation. 33 Fabrication Of Display Board Made Of M.S. Angle Iron 50X50X6Mm, 3 Long Support And M.S. Board Of 2X1 M.S. Sheet 18 Gauge And M.S. Flat Iron 25X6Mm Size 2X1 Welded On M.S. Sheet After Then M.S. Pipe Of 1.5\ Dia. Fitted Around M.S. Flat On The Sheet Board And 0.5\ Dia M.S. Pipe 4\ Long Welded In M.S. Angle Iron From Two Places At One Side And Two At Other To Complete The Display Board. Digging Pit Size 2X2X3 And Grouting Above Board With 1:2:4 Cement, Ballast, Sand Ratio And Making Plinth Of Size 1X2. Board Shall Duly Painted By Yellow Color And Equipment Name Shall Be Written In Black. 34 Integration Of Newly Contructed 33Kv Bay With Iec 61850 Based Scada System. The Work Includes Sld Generation For Feeder Bay In Existing Hmi,Bay Ieds, Ics Files Configuraration Data Base Creation For Newly Bay ,Event Alarm Greeration ,Interlocks And Soft Logics Configuration And Testing If Any Gps Time Synchronisation Etc. 35 Supply 36 Pg Clamptarantull To Zebra Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 37 Pg Clamp Zebra To Zebra Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 38 Pg Clamp Panther To Panther Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 39 Pg Clamp Zebra To Panther Made Of Lm-6 Alloy Four Bolted Type Complete With Good Quality Nut Bolt Washer And Spring Washer Exactly As Per Sample In Ready To Use Condition. 40 Supply Of Gi Nut Bolt Of Size 16X40Mm 41 Supply Of Gi Nut Bolt Of Size 16X45Mm 42 Supply Of Gi Nut Bolt Of Size 16X50Mm 43 Supply & Fixing Of 150W Outdoor Type Flood Light Complete Fitting With All Fixing Accessories Including Bracket And Clamps Of Philips/Crompton/Havells/Bajaj/Halonix Make. Original Warranty Card Should Also Be Submitted Along With Above Material. 44 Supply Of 75X10Mm Ms Flat 45 Supply Of 50X6Mm Ms Flat 46 Supply Of 25X6Mm Ms Flat
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
32.
Public Administrative Department #11351699 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Hafed District Manager Sirsa Tender Inviting Authority: Hafed District Manager Sirsa Contract No: Name Of The Bidder/ Bidding Firm / Company : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Works Details Item Code / Make Quantity Units Amount Of Earnest Money Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency In Figures To Be Entered By The Bidder As Amount Rs. (Including Gst/Taxes) Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Total Amount Without Taxes In Rs. P Total Amount With Taxes Total Amount In Words , For Installation Of New Steam Boilerof 0.5 Tph Capacity, Chimney And Its Accessories To Be Supplied And Commissioned Is As Under:- I. 0.5 Tph (F & A 100̊ C) 10.54Kg/Cm2 Effypac Boiler (Fuel To Be Used- Wood/Briquettes). Ii. Chimney With 30 Mtrsheight Anddia 500Mm Iii. Interconnecting Piping. Iv. Feed Water Tank 2Kl With Mounting Structure And Insulation. V. Steam Header With Mountings (1Inlet 50Nb And 2 Outlet 50 Nb). Vi. Supervision Of Erection & Commissioning Including Transportation. Total In Figures 0.0 0.0 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only , Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Hafed District Manager Sirsa Tender Inviting Authority: Hafed District Manager Sirsa Contract No: Name Of The Bidder/ Bidding Firm / Company : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Works Details Item Code / Make Quantity Units Amount Of Earnest Money Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency In Figures To Be Entered By The Bidder As Amount Rs. (Including Gst/Taxes) Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Total Amount Without Taxes In Rs. P Total Amount With Taxes Total Amount In Words , For Installation Of New Steam Boilerof 0.5 Tph Capacity, Chimney And Its Accessories To Be Supplied And Commissioned Is As Under:- I. 0.5 Tph (F & A 100̊ C) 10.54Kg/Cm2 Effypac Boiler (Fuel To Be Used- Wood/Briquettes). Ii. Chimney With 30 Mtrsheight Anddia 500Mm Iii. Interconnecting Piping. Iv. Feed Water Tank 2Kl With Mounting Structure And Insulation. V. Steam Header With Mountings (1Inlet 50Nb And 2 Outlet 50 Nb). Vi. Supervision Of Erection & Commissioning Including Transportation. Total In Figures 0.0 0.0 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 2
33.
Petroleum and Natural Gas #11346768 AOC
Bids Are invited for Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A-1) 4 core 4 Sq. mm , Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. (a) 3 core 2.5Sq. Mm , Laying of XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (G) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core) , Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (C) 4 core 25 Sq. mm , Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. (D) 3 core 10 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (a) 2 to 4 core 2.5/ 4 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (A)3 core 2.5 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (E) 4 core 25 Sq. mm , Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (c) 3 core 10 Sq. mm , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A)4Sq.mm , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 2.5 Sq.mm , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (D) 25 Sq.mm. , Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 10 Sq.mm , Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground. , Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground. , Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks per meter) , Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 50 K.A. and above at 415 V having Normal current rating 400A with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing [ ICS=100% of ICU only, Cat III] , Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. , Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , Disconnecting the cable connection and Providing straight joint with PVC mould using heat shrink /cast resin type epoxy compound Insulating material and making the joint complete using necessary in line connectors, hardener, earth continuity connection, spacers etc. and reconnecting the same & ensure the joint resistance within the limits as per IS. (B)3.5C 50 Sq. mm cable. , Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge.(5) 300 X 50 X 2.0 mm Thick , Providing and fixing approved make 90° Elbow for Perforated C type cable tray. Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge. (5) 300 X 50 X 2.0 mm Thick 90° Elbow , Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge. (2) 100 X 50 X 1.6 mm Thick , Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. , Providing cement concrete.for foundation or for concrete filling in 1:2:4 ratio with 20 to 25 mm stone metal duly plastered with necessary curing for pole muffing or any other purpose.
Contract Date: Ref. Documents Contract Value : 9.58 Lakh
Boards / Undertakings / PSU No of Bidders 4
36.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
37.
Power #11339668 Technical Bid
Tender For Installation Of New 250 Kva Distribution T/F At Deen Dayal Upadhyay, Vidhya Mandir, Baijnah Ghar, Aman Ki Dukan, Ram Janki Mandir, Ashram Ke Samne, Adraula Mau, Shaeed Path, Rishita Ke Samne, Mi, Aryan Agar, Vijay Lohia, Shishu Mandir Dayananad Puram At 33/11 Kv Substation-Arjunganj In The Area Of Executive Engineer- 11 Kv & Lt-Rajbhawan, Central Zone, Lucknow Under Business Plan 2026-27- 1 Safe Carriage, Loading-Unloading With Proper Stacking Of Following Material From Esc-Daliganj To Work Site/Je -Dump Store – 2 11/0.4 Kv 250 Kva T/F 3 Lt Abc (3X120+1X95+1X35) Sqmm 4 11Kv Polymeric Pin Insulator 5 St Pole 11 Mtr Long 6 Lt Pvc Cable 1X400/3.5X240 Sq Mm Cable 7 11 Kv 3X70 Sqmm Xlpe Cable 8 11Kv O/Door Jointing Kit 3X70 Sq Mm 9 Pcc Pole 8.5 Mter Long 10 3 Phase Lt Distribution Box With Clamp 11 Safe Carriage Loading Unloading With Proper Stacking Of Following Material From Je Dump Store To Work Site. 12 11/0.4 Kv 250 Kva T/F 13 Lt Abc (3X120+1X95+1X35) Sqmm 14 11Kv Polymeric Pin Insulator 15 St Pole 11 Mtr Long 16 Lt Pvc Cable 1X400/3.5X240 Sq Mm Cable 17 11 Kv 3X70 Sqmm Xlpe Cable 18 11Kv O/Door Jointing Kit 3X70 Sq Mm 19 Pcc Pole 8.5 Mter Long 20 3 Phase Lt Distribution Box With Clamp 21 Construction Of Distribution Pillar Box Made Of Ms Sheet (All The Material Will Be Arranged By The Contractor). 22 Fixing Of 3 Phase Lt Distribution Box 23 Construction Of Transformer Plinth 24 Construction Of Fencing For 250 T/F 25 Chemical Earthing System With Outer Pipe Diameter 50Mm, Inner Strip 40X6, Length 3000 Mm. Galvanization Up To 200 Micro, Earthing Pipe With Crystalline Conductive Mixture Filled Inside The Pipe With Anti-Corrosion & High Conductive Along With 50 Kg(As Per Required) Of Bfc Which Should Be Capable To Reducing The Soil Resistively With Good Moisture Retaining Capacity.. All Material Shall By Supply By The Contractor. 26 Providing Earthing Strip Size 50X6Mm And Connecting From Earthing Pipe/M.S.Earting Rod To Fuse Unit/Tronsformer Body/Neutral Earthing (Earthing Rod & Earthing Strip Arranged By Contractor). 27 Fabrication & Erection Of Single Pole For Lt Line On 8.5 M Long Pcc Pole With Fixing Of Necessary Clamps & Other Acessories Like Clamp Hook, Dead/Suspension Clamp,Neutral Clamp,Abc Pressure Clamp (If Required) And Danger Board With Clamp.(All Material Arranged By Contractor Except Steel & Pole If Required). 28 Fabrication And Etection Of S/S Type Double Pole For 11 Kv Line On 11 Mtr Long St Pole Structure & Installation, Commissining Of 100/250 Kva T/F On Double Pole Including Jumpring With The System (All The Required Material For Above Job Shall Be Provided By Contractor Except (T/Fs) 29 Placement Of 11/0.4 Kv T/Fs On S/S Type Installation, Commissioning Of 250 Kva T/Fs Jumpering With The System ( All The Required Matrial For Above Job Shall Be Provided By Contractor Except T/Fs) 30 Placement Of 11/0.4 Kv T/Fs From Dump Place To Newly Constructed T/Fs Plinth & Installation, Commissioning Of 250 Kva T/Fs Of T/F Plinth And Including Jumpering With The System ( All The Required Matrial For Above Job Shall Be Provided By Contractor Except T/Fs) 31 Hoisting, Winding And Jumpering Of Lt Cable Size 1X240/400 &3.5X240/400 Sqmm Between Lt Distribution Box/Fuse Unit & Constructed Overhead Line With Proper Lugging And Clamaping. 32 Stringing, Sagging, Winding And Jumpering Of Lt Line With Ab Cable (3X120+1X95+1X16) Conductor As Per Resspo Norms. (Ab Cable Provided By Deptt And Balance Material Like Holding Clamp, Eye Hook, Suspension Clamp And Dead End Clamp Arranged By Contractor .) 33 Supply & Fixing Of Following Material
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
39.
Heavy Industries and Public Enterprises #11338173 AOC
Bids Are invited for Assets Insurance Service - Terrorism Insurance, Electronic Equipment Insurance, Marine – Cum – Erection (Mce), All Risk Policy, Money Insurance, Fire Insurance, As Per Scope Of Work, As Per Scope Of Work Attached, Advance Loss Of Profit (Alof) Insura.. - Industrial All Risks Policy -Covering At Various Locations (A) Dock Yard Road, Mazagaon, Mumbai: 400 010. (B) Anik Chembur Yard, Chembur , Mmbai ( C ) Nhava Seva1.1 Section I - Material Damage. For All Properties Of Mdl Including Factory &Office Buildings, Other Civil Structures, Plant &Machinery, Electrical Installations, Material Handling Equipment (Cranes & Other Similar Items), Electromechanical Equipment & Electronic Equipment, Computers, Servers, And Other Peripherals, Fff, Office Equipment, Etc. 1.2 Machinery Breakdown Sectionall Plant & Machinery (Including Electrical Installations, Cranes, Handling Equipment, Computers, Servers, And Otherperipherals 1.3 Section-Ii Business Interruption , Contractors Plant & Machinery Insurance , Bharat Grih Raksha Policy (Residential Premises Including Guest Houses) , Bharat Sookshma Udyam Suraksha Policy , Bharat Laghu Udyam Policy , Burglary Policy For Contents Of Properties Covered Under Bgrp, Bsusp And Blusp , Marine Hull Policies For Tugs &Barges , Various Motor Policies , All Risk Policy For Laptops/ Tabs/ Electronic Gadgets (Including Laser Tracker, Ai Enabled Equipment) , Stocks/Stores/ Spares/Raw Materials At Various Warehouse –Sfsp , Stocks/Stores/ Spares/Raw Materials At Various Warehouse –Burglary +Theft -5% Floater Basis , Marine Transit ( Import/Export) Open Cover , Marine Inland Policy For Goods-Inter/Intra Yard , Fidelity (Floater) Guarantee Policy , Money Policy (In Transit Insurance/ Counter/Safe) , Public Liability (1991 Act) Policy Aoa : Aoy , Comm. Gen. Liability Ins. Aoa : Aoy (1:2) , Directors & Officers Liability Insurance Policy , Special Group Personal Accident Policy (During Launching & Sea Trial)
Contract Date: Ref. Documents Contract Value : 6.90 Crore
Boards / Undertakings / PSU No of Bidders 9
Maharashtra View Result →
41.
Agriculture #11333050 Technical Bid
Tender For Fabrication And Erection -- 1 Boiler 2 Dismantling, Fabrication, Erection Of Leak Proof Dampers At Pa, Sa,Fd & Id Fans 3 Dismantling, Fabrication & Erection Of Air Heater Outlet Top Plate. 4 Dismantling, Fabrication, Erection Of Ro Water Storage Tanks Canopy And Railing. 5 Dismantling, Fabrication & Erection Boiler Furnace Ash Discharge Hopper 6 Dismantling, Fabrication & Erection Of Air Heater Outlet Bottom Plate. 7 Dismentling , Fabrication Erection Of Rotory Bagasse Feeder Casing 8 Dismentling , Fabrication Erection Of Belt Conveyor Structure 9 Dismantling, Fabrication & Erection Of S.A. Fan Foundation 10 Dis, Fabrication And Erection Work Of Expansion Bellows At Fd, Id, Esp, Economizer, Aph 11 Ducting Work With Structure 12 Strengthening Of Ducting Of Boiler. 13 Dismantling, Fabrication & Erection Of F.D. Fan Foundation 14 Dis, Fabrication And Erection Of Id Fan Upper & Lower Casing 15 Dis, Fabrication And Erection Of F.D. Fan Upper & Lower Casing 16 Dismantling, Fabrication & Erection Of Drum Type Rotary Bagasse Feeder (With Shaft) 17 Dismantling, Fabrication & Erection Of Screw Feeder 18 Dismantling, Fabrication & Erection Of Screw Feeder Casing. 19 Fabrication & Erection Of Man Hole 24”X24” 20 Dis., Fab & Erecting Of Aph Tubes (Replacement) 21 Dis, Fab & Erection Of R.O Plant Pressure Vessel Stand 22 Fab & Erection Of Fire Fighting Pipe Line Including Valves, Bends, Flange & Support ( Using New Pipeline & Old Drum To Drum Tubes) 23 Travelling Grate Front Side Ash Discharge Plate Dis, Fab & Erection With Structure 24 Fab & Erection Of Travelling Grate Rear Plate Flange (Flange Type ) 25 Fabrication & Erection Of Pneumatic Spreader Assembly From 10 Mm Thk. S.S. Plate With Fabrication & Erection Of Deflector Plate From 20Mm Thk. S.S. Plate With Top & Bottom Flange 26 Dismantling Of Old Pneumatic Spreader Assembly & Internal Deflector Plate 27 Dismantling & Fitting/ Replacement Of Id Fan Impeller 28 Fabrication & Erection Of Id Fan Suction Bend 29 Fabrication & Erection Of Id Fan Suction Cone 30 Fabrication & Erection Of Plate & Spindle Type Damper With Flanges 31 Dismantling, Fabrication & Erection Of Rotary Soot Blower 32 Dismantling, Fabrication & Erection Of Long Retractable Soot Blower 33 Dismantling, Fabrication & Erection Of Economizer L.H.S. & R.H.S From 6 Mm Thk. M.S. Plate With Strengthening From 65 X 65 Angles 34 Fabrication & Erection Of 1.5 Kg/Cm2 Prds, Exhaust & Vapour Pipeline From 10Mm Thk. M. S. Plate 35 Fabrication & Erection Of 1.5 Kg/Cm2 Prds, Exhaust & Vapour Pipeline Drains 36 Dismantling, Overhauling And Fitting 1.5 Kg/Cm2 New Prds(25 Tph) 400 N.B Valve 37 Dismantling, Fabrication & Erection Of New Bagasse Discharge Chute At Return Bagasse Carrier With Gate Arrangement Complete Set In All Respect 38 Fabrication And Erection Of Boiler Outlet/Economizer Hopper 39 Fabrication And Erection Of Water Monitor On Fire Fighting Line 40 Fabrication And Erection Of Fd Fan Suction Cone 41 Replacement Of Travelling Grate Skid Rail 42 Boiling House 43 Platform Work At Various Stations Such As Mill House, Boiler, Turbine, Cranes, Boiling House, C/F House Etc. If Required Anywhere With Structure Strengthening 44 Dismantling , Fabrication & Erection Of Foundation Of Pump & Motor 45 Fitting Of Motor 46 Repairing Of Exhaust Valve 47 Fab & Erection Of Double Filtration System For Quad & Water Inlet Pipe In Pan Condenser. 48 Arrangement For Lifting Of Vaccum Filtered Drums-3 Nos 49 Replacement Of Exhaust And Vapour Valves In The Boiling House. Dis 50 Replacement Of Exhaust And Vapour Valves In The Boiling House Erec- 51 Fabrication Of Electric Motor Cover. 52 Strengthening Of Vapour Pipe Inside & Outside With Angle Iron Rings/ M.S.Plate. 53 Manhole Work In Vapour Pipes/Headers 54 Modification In Bagacillo Chimney 55 Replacement Of Vapour Pipe. A) Dis 56 Replacement Of Vapour Pipe. B) Fab 57 Replacement Of Vapour Pipe. C) Ere 58 Exhaust And Injection Pipeline A) Dis 59 Exhaust And Injection Pipeline B) Fab 60 Exhaust And Injection Pipeline C ) Ere 61 Replacement Of V.Pipe Bends Dis 62 Exhaust & Injection Bends Fab- 63 Exhaust & Injection Bends Erec. 64 Dis,Fab & Ere Of Final Molasses Pipeline 65 Dis,Fab & Ere Of Suction Pipe For Injection, Ct Pump 66 Fab & Erection Of M.S. Vessels, Square & Rectangular Tank 67 Increase Of Shell Height With All The Fitting And Accessories Work. 68 Dis, Fab & Erection Of M.S.Plate Work 69 Dis,Cleaning & Ere Of Pipeline (Juice, Massecuite, Srrup, Molasses Etc) 70 Dis,Fab & Ere Of Coil(Water,Juice,Ammonia,So2Etc) 71 Fab And Erection Of Motor Bed 72 Dis,Fab & Ere Of Nrv For Injection, Turbine, Spray Etc 73 Saveall Of Pan,Quad Dis 74 Saveall Of Pan,Quad Fab 75 Saveall Of Pan,Quad Ere 76 Unloading Of Material From Truck (Ms, Ss, Ci, Acc Etc) 77 Dis, Fab & Ere Of Jay Pipe 78 Fitting Of Baffle Plates 79 Dismantling, Fabrication & Erection Of Belt Conveyor Structure 80 Clarifier Coil Work A) Dismantling 81 Clarifier Coil Work (B) Fabrication 82 Clarifier Coil Work ( C) Erection 83 Dismantling, Fabrication & Erection Of Perforated M.S Plates Of Direct Contact Juice Heaters. 84 Dismantling , Fabrication & Erection Of Strainers Of Injection, Spray , C.T Pumps. 85 Dismantling, Erection (With Alignment) Of Planetary Gear Box Of Crystallizers. 86 Nozzles Of Spray Pond, Condenser. 87 Dismantling (Each Nozzle) 88 Fitting (Each Nozzle) 89 Replacement Of Double Beat Valve 90 Dismantling , Fabrication & Erection Of Exhaust Valve Casing 91 Opening & Fitting Of Juice Heater Covers 92 Dismantling & Fitting Of S.S Tubes In Juice Heater & Evaporator Body 93 Dismantling, Fabrication & Erection Of Mud Mixture Conveyor 94 Dismantling, Fabrication & Erection Of Mud Mixture Casing 95 Dismantling, Fabrication & Erection Of Down Take Umbrella Of Pan 96 Replacement Of 3’’ Coil Of Vertical Crystallizer 97 Gutter Work (Bigger Side Will Be Treated As Dia.) 98 Gutter Work Dismantling 99 Gutter Work Fabrication 100 Gutter Work Erection 101 Jammed Tube Falling Film Evaporator 102 Replacement Of Sluice Valve 103 Fabrication / Strenghting Of Beam, Vessel, Pipe, Channel, Angle Etc. 104 Dis, Fabrication & Erection Of 7 Kg/Cm2 Prds Pipeline 105 Dis, Fabrication & Erection Of 7 Kg/Cm2 Prds Pipeline Drains 106 Replacement Of Readymade Bend 107 Replacement Of Ammonia Pipe Of Pan & Quad 108 Replacing Of Worn Out Brass Zig Zags & S.S Screens Of Vacuum Filter 109 Dismantling, Fabrication & Erection Of M.S Plate ( As Required) 110 Dismantling Of Existing Syrup Sulphitor & Shifting To Scrap Yard 111 Dis., Fab & Erection Of Save All Cone Of Evaporator And Pans 112 Dismantling, Installation And Alignment Of Reduction Gear Box. 113 Dismantling, Fab & Erection Of Agitator 114 Fitting & Replacement Of Batch Type Machine 115 Fitting & Replacement Of Continuous Type Machine 116 Replacement Of Exhaust Balloon 117 Replacement Of Savall Of Quad And Pan 118 Replacement Of Screw Type Arm Of Crystallizer 119 Replacement Of Drive Of Vertical Crystallizer 120 Replacement Of Tube Of Quad And Juice Heater 121 Dis, Fab. & Erection Of Foundation For Clarifier Drive 122 Dismantling, Fabrication & Erection Of Cover Of S400 Semi-Kestner 123 Replacement Of S.S. Pipelines Including Pipe Fittings 124 Replacement Of Seamless Pipeline Including Pipe Fitting 125 Replacement Of Magma Mixer With Arm, Bracket & Gear 126 Dismantling, Fabrication & Erection Of Underground S.S. Pipeline For Condensate Water 127 Dismantling, Fabrication & Erection Of Cone As Per Requirement 128 Modification Of Bagasscillo Cyclone 129 Dismantling, Fabrication, Assembly And Trial Of Mechanical Circulator 130 Modification In Exhaust & Vapour Valve 131 Dismantling, Fabrication & Erection Of Spray Pond Header 132 Dismantling, Fabricaton & Erection Of Basket Housing Cover & Bottom Discharge Chute Of Centrifugal Machine 133 Dismantling, Fabrication & Erection Of Arms Of Clarifier 134 Dismantling, Fabrication & Erection Of Down Tape Of Evaporator Bodies 135 Fabrication & Erection Of Molasses Jacket For Batch Type C/F M/C 136 Hydraulic Testing Of Vertical Crystallizers Complete In All Respects 137 Dismantling, Fabrication & Erection Of Various Stations For Entrainment Catcher 138 Dismantling & Installation Of Super Heater In Boiling House 139 Dismantling & Installation Of Oil Cooler At Turbine 140 Dismantling, Fabrication & Erection Of All High Pressure Line Drains At Turbine 141 Replacement Of Cut Over Valve For Pan 142 Modification Work In Juice Line Below Quad Station 143 Dis., Fabrication & Erection Of Grit Conveyor 144 Dis., Fabrication & Erection Of Sugar Hopper 145 Dis., Fabrication & Erection Of M.S. Tank/Vessel 146 M.S. Pipeline Replacement 147 Dis., Fabrication & Erection Of Vapour/ Exhaust Line From Quad To Pan Station 148 Dismantling And Fitting Vapour/Exhaust Valve 149 Dismantling, Fabrication & Erection Of Bagassecillo Line 150 Dismantling, Fabrication & Erection Of Underground & Outside Pipeline Of All Sizes 151 Boiler/Turbine, Cooling Tower Sugar Godown/Workshop/Store/Cane Unloader & Factory 152 Fab & Erection Of Gate 153 Strengthning Of Tress Beams,Vessel,Pipe With Channel,Angle,Pipe Etc Any Where 154 Fab & Erection Of M.S.Stair/Ladder Single Story 155 Fab & Erection Of M.S.Stair/Ladder Double Story 156 Dismantling, Fabrication & Erection Of Underground And Outside Pipeline Of All Sizes 157 Fabrication & Erection Of Nrv Of Ct Pump 158 Dismantling, Fabrication & Erection Of Turbine Silencer 159 Dismantling, Fabrication & Erection Of Cooling Tower Pipeline From Cooling Tower Of Turbine 160 Misc .Items. 161 M.S Pipeline Per Inch Dia//Ft/Length (A ) Dismentling Of Pipe Line. 162 Upto 1” Dia To 12’ Dia. 163 Above 12” 164 Fabrication Of Pipe Line From M.S.Plate Or Ready-Made Pipe Any Dia. 165 Erection Of Pipe Line Per Inch Dia/Ft/Length (I) Upto 1’ Dia To 166 Erection Of Pipe Line Per Inch Dia/Ft/Length (Ii. Above 12” Dia 167 M.S.Pipe Accessories Work, Dismantling Of Bends, Tee, Reducder, Cross, Elbow, Nipple, Nozzle, Flanged, And Bends. (Per Inch Dia/Ft/Length ) (A) Upto 1”Dia To 12” Dia 168 M.S.Pipe Accessories Work, Dismantling Of Bends, Tee, Reducder, Cross, Elbow, Nipple, Nozzle, Flanged, And Bends. (Per Inch Dia/Ft/Length (Ii.) Above 12” Dia. 169 Fabrication Of Bends, Tee, Reducer Etc.-(P.Inch Dia/Ft) (I) Upto 1”Diato 12” Dia 170 Fabrication Of Bends, Tee, Reducer Etc.-(P.Inch Dia/Ft) ( Ii) Above 12\ Dia.. 171 Erection Of Bends, Tee Etc.(Per Inch Dia/Ft/Length) (I) Upto 1” Dia To 12” Dia 172 Erection Of Bends, Tee Etc.(Per Inch Dia/Ft/Length) Ii) Above 12” Dia 173 Valve Work 174 Dismantling Of Valves, (Per Inch Dia/Pc) Upto 1” Dia To 12” Dia 175 Dismantling Of Valves, (Per Inch Dia/Pc) Above 12” Dia 176 Erection Of Valve 177 Dismantling Of Valves ,(Per Inch Dia/Ft/Length) (I) Upto 1” Dia To 12” Dia 178 Dismantling Of Valves ,(Per Inch Dia/Ft/Length( Ii) Above 12” Dia 179 Plateform Work (Per Sft) 180 I) Dismantling 181 Ii) Fabrication And Erection 182 A) Patch Work With Old Material. 183 B) Patch With New Material . 184 Purling In Work.(Per Rft) (I) Dismantling 185 Fabrication & Erection 186 Cutting Of Old Flange Repairing For Reuse & Fitting 187 Dis, Fabrication And Erection Of Distance Piece 188 Mill House 189 Replacement Of Ms Plate Work, Weak Portion Of Cane Carrier, Chopper, Leveller, Fibrizer, Bagasse Elevator, Mbc,Rbc,Bc Etc A) Dismantling 190 Replacement Of Ms Plate Work, Weak Portion Of Cane Carrier, Chopper, Leveller, Fibrizer, Bagasse Elevator, Mbc,Rbc,Bc Etc B) Fabrication 191 Replacement Of Ms Plate Work, Weak Portion Of Cane Carrier, Chopper, Leveller, Fibrizer, Bagasse Elevator, Mbc,Rbc,Bc Etc C) Erection 192 Hc Flat Replacement Angle, Beam & Channel. 193 Dismantling, Fitting & Alignment Of C-Channel & Teflon Runner Of Rake Carriers . 194 Fabrication & Erection Of Trpf Cover 195 Dismantling, Fabrication & Erection Of Guide(Salami) 196 Dismantling, Fabrication & Erection Of Trough Of Bagasse Carriers 197 Dismantling, Fabrication & Erection Of Bagaescillo Pipe 198 Fabrication & Erection Of Discharge Chute 199 Dismantling, Fabrication & Erection Of Be,Mbc & Rbc Trough 200 Dismantling, Fabrication & Erection Of Be,Mbc & Rbc Side Plate 201 Dismantling, Fabrication & Erection Of Discharge Chute Of Mbc Belt Conveyor 202 Dismantling, Fabrication & Erection Of Foundation Bed Of Pump, Motor, Gear Boxes 203 Fabrication & Erection Of Weak Portion Of Cane Unloader Bridge, Trolley Etc 204 Dismantling,Fabrication & Erection Of Square Bar Of Cane Unloader 205 Dismantling Of Old Rotary Screen Between Mill 1 & Mill 2. 206 Modification In The Mbc Chain As Per New Rbc Belt System. 207 Dismantling Of Complete Rbc Structure. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Contract Date: Jul 03, 2026 Contract Value : 2.76 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
West Bengal View Result →
45.
Heavy Industries and Public Enterprises #11321092 Technical Bid
Tender For Civil And Mep Works For Setting Up Hindlabs Minor Lab, Barpeta, Assam- 1 Civil Works 2 Solid Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 3 12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 4 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 5 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 6 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 7 Providing And Laying Premiumvitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier,Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt/Antiskid Finish Of Size Size Of Tile 600 X 1200 Mm 8 Providing And Laying Premium Vitrified Wall Tile In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600 X 1200 Mm 9 Providing And Fixing Fiber Glass Reinforced Plastic (Frp) Door Frames Of Cross- Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminated Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. 10 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 11 Providing And Fixing To Existing Door Frames.30 Mm Thick Fiberglass Reinforced Plastic (F.R.P) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam (Puf) / Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel, Casted Monoolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is : 14856, Complete As Per Direction Of Engineer- In-Charge. 12 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 13 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 14 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 15 Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm,With Swan Neck Faucet With Pipe In Let And Drain Provision, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink With Drain Board510X1040 Mm Bowl Depth 250 Mm 16 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms 17 Providing And Fixing Cp Towel Rod Complete Fixed With Cp Brass Screws Of Approved Quality Of Minimum 600Mm Length Approved As Per The Requirement Of Engineer In Charge. 18 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions: 45 Cm Length15 Mm Nominal Bore 19 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 40 Mm Dia 20 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 21 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 10Kgf/Cm2 22 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work,Including Cutting Chased And Making Good The Wall Etc. 20 Mm Pipe 12 Kgf/Cm2 23 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall 24 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clips/ At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf/Cm2 - External Work- Exposed On Wall 25 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia 45 Degree Elbow 26 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75X75X75 Mm Dia Door Tee 27 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Bend 28 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 29 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes,Including Jointing With Pvc Solvent Cement - 75 Mm Dia Vent Cowl 30 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia End Cap 31 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia End Cap 32 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X110 Mm Dia Door Tee 33 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 34 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf/Cm2 - External Work- Exposed On Wall 35 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Partition Of Approved Brand And Manufacture, Including Top & Bottom Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Fittings, All Complete As Per Direction Of Engineer-In-Charge. 36 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle, Lock And Stopper Etc To Be Paid Separately) 37 Providing And Fixing Ss H Handle Having Min 45 Cm Length In Toughed Glass Door Including All Necessary Screws Etc. Complete. 38 Providing And Fixing 3M Fasara Frosted Etching Film Of Thickness 25 Microns Self- Adhesive Of Approved Colour, Shade, And Quality With Cutting As Per Approved Design And Pattern, Including Cleaning Of Glass And Making Surface Smooth For Fixing Of Film To The Surface, All Completed As Per The Direction Of The Engineer In Charge. 39 Providing And Fixing Of Glass Door Ss Patch Lock With Out Handle In Toughened Glass Door Including All Necessary Screws Etc. Complete 40 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 41 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 42 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides 43 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 44 Filling The Gap In Between Aluminium/ Stone/ Wood Frame And Adjacent Rcc/ Brick/ Stone/ Wood/ Ceramic/ Gypsum Work By Providing Weather/Structural Non Sag Elastomeric Pu Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete,Complying To Astm C920, Din 18540-F & Iso 11600Upto 5 Mm Depth And 5 Mm Width 45 Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 46 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Single Rubber Stopper 47 Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In- Charge. 48 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 49 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised(Anodic Coating Not Less Than Grade Ac 10 As Per : 1868), Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 50 Vinyl Transparent Vision Glass Stickers: Supply And Pasting Of Vinyl Transparent Vision Glass Stickers In Approved Size And Design In Glass Partition And Door As Per The Instruction Of Engineer In Charge. 51 Backlit Acrilic Board With Projected Letters: Supply, Installation, Testing And Over Suitable Welded And Painted 25X25X3Mm Ms Angle Frame In Suitable Location And In Proper Line And Level With All Necessary Fastners, Supports Etc. Electrical Works Likes Electrical Wirings, Connections, Fittings, Externaly Fixed Weather Proof 2/3 Pin Plug Points And Sockets Including Boxes Etc. To Be Complete Properly. All Fabrication And Fixing Should Be Done As Per Approved Design And Instructions Of Engineer In Charge. (Note: Only Front Elevation Will Be Measured.) 52 Furniture 53 Supply And Erection Of Airport Type 3 Seater Waiting Chair With Powder Coated Chromium Finish Having Minimum Dimensions 1675Mm Length X 710Mm Width X 775Mm Total Height And 400Mm Seat Height . Seat: High Quality Cold Rolled 1.2Mm Thick Steel Perforated Sheet Pressed And Welded To Form The Shape. Arm & Leg: High Quality 1.2Mm Thick Ms Tube / Sheet . Cross Bar: High Quality Cold Rolled 2Mm Thick Steel Sheet Pressed And Welded To Form The Shape. 54 Supply Of Phlebotomy Chair With Optimum Design Made Up Of Ms Power Coated Frame And Up Upholstery Type Seat,Back Rest And Arm Rests.Both Side Arm Rest Should Be With Height And Position Adjustable System And All As Per The Instruction Of Engineer In Charge. 55 L-Type Workstation Of Overall Size (1350 * 600)Mm + (1000 * 450)Mm X 750 Mm (L X D X H) And Pedestal Unit Made Up Of 18 Mm Thick Exterior Grade-I Mdf Board On All Sides Conforming To Is:14587 From Approved Makes Such As Century/Greenply/Fineply Or Equivalent With Decorative Laminate On Both Side And All Edges To Be Fixed With 2Mm Thick Pvc Edge Beading. One Three-Drawer Modular Pedestal Unit Of Minimum Size 450 Mm (W) X 500 Mm (D) X 650 Mm (H) All With Retractable Key Board Tray, Drawer Channels, Hinges, Handles, Individual Locking System, And All Necessary Fittings And The Workstation Should Have An Electrical Flip Box With 2 Nos Universal Power Socket & 1 No Data Socket Etc And Cable Management Tray. All Work As Per The Approved Design And Instruction Of The Engineer-In-Charge/Architect. 56 Providing And Erection Of Reception Counter Table Of Length 1200 Mm And First Level Should Be Provided At A Height Of 750 Mm And Width 600 Mm And The Second Level At A Height Of 1050Mm From Base With A Width Of 300. The Table Made Of 18Mm Thick Pre Laminated Medium Density Board Of Exterior Grade (Grade I) Is: 14587:1998 With Decorative Laminated Finish On Both Sides And 2 Mm Thick Pvc Beading On All Edges, Including Electrical Flip Box, Cable Measurement Tray, Grommets With 3 Nos Universal Power Socket And Ethernet Port, Three Drawer Pedestal Unit With Drawer Channel, Handles, Hinges, Lock All Complete As Per Approved Drawing And Installation Of Engineer In Charge/Architect. 57 Supply And Installation Of Visitors Chair Medium Back, Mesh Back Cushion Seat With Fixed Supports Made Of 304 Stainless Steel/ Powder Coated Ms Of Approved Colour Or Shade As Per The Instruction Of The Engineer In Charge 58 Revolving Chair: Medium Back Ergonomic Chair With Five Nos. Star Shaped Nylon Base. Castor: 50Mm Diameter Nylon Twin Wheel, Gas Lift Height Adjustment, Back Angle Adjustment , Fixed Armrest Providing Natural Resting For Arms. Seat With Pu Coated Foam Backed Fabric, Back Rest With Mesh Type Fabric, Upholstery: Heavy Duty Rubber Backed Fabric In Black 59 Counter Height Stools :Supply And Erection Of Counter Height Stools ( Bar Stools ) Of Following Specifications : Revolving Adjustable Chrome Plated Steel Body Chairs With Resistance To The Corrosion. Cushion Seat With Lift Mechanism For Adjustment Of Height. Minimum Height 750Mm Before Expansion. Medium Back Rest And Arm Rest. Item Shall Be Of Reputed Make. 60 Supplying And Fixing Of Lab Work Table With 18 Mm Thick Edge Moulded Granite Top Supported Over 18Mm Thick Marine Ply Wood Of 2500Mm,L X 1200Mm,W X 850Mm, H And Powder Coated Gi Frame Of Section Size Not Less Than 50X50X1.5 Mm Including And Providing 4 Nos Under Storage Movable Cabinents Of Size 600Mm,L X 450Mm,D X 750 Mm,H And Powder Coated Steel Sheet Of Thickness Not Less Than 1Mm With 1 Drawer And Partition Bottom Storage Space With Door Including Drawer Channels, Individual Locks And Handles All As Per The Approved Drawing And Instructions Of Engineer In Charge 61 Lab Work Bench -The Work Bench Top Made Up Of 18Mm Thick Granite Top Edge Moulded Over 18 Mm Thick Marine Plywood And Gi Powder Coated Frame Work Of Section Size Not Less Than 50X50X1.5Mm. The Width Of The Table Shall Be 750Mm And Height Shall Be 850Mm. The Frame Provided With Level Adjusting Screws Fixing Accessories ,Carriage Of Material All Complete As Per The Approved Drawings And Direction Of Engineer In Charge.Note Only Length Of The Table Shall Be Measured For Making Payment. 62 Cabinet/Wardrobe: Providing And Errection Of Cabinet/Wardrobe Unit Made With 18 Mm Thick Prelaminated Mdf Board Of One Side Decorative Lamination And Other Side Balancing Lamination Having Total Unit Dimension Of 900Mm,L X 450Mm,Dx 2400Mm,H And All Edges To Be Sealed With Pvc Edge Beeding Of 2.00 Mm Thick Including All Fittings Such As Autoclose Hinges,Chromium Plated Brass Individual Locks & Handles ,Tower Bolts Etc All Required. All Shelves To Be Fix With Proper Support And Bracket Holders At A Spacing Of 400 Mm Centre To Centre And All As Per The Drawings And Instruction Of Engineer In Charge. Board Make : Greenlam/ Merino / Century/ Equivalent . Only Front Elevation Will Be Measured. 63 Overhead Storage: - Providing And Fixing Overhead Storage Unit With Minimum 18 Mm Thick Pre-Laminated Medium Density Fiber Board Exterior Grade (Grade-I) Is: 14587:1998 Marked With One Side Decorative And Other Side Balancing Lamination. Cupboard Shutters Edge To Be Sealed With Pvc Edge Bending Tape 2.00 Mm Thick Of Approved Brand Including Isi Marked Nickel Plated Bright Finishing M.S. Piano Hinges Conforming To Is:3818 Marked With Fixing Chromium Plated Brass 50 Mm Cupboard Or Wardrobe Knobs, Special Quality Chromium Plated Brass Cupboard Locks With Six Levers Of Approved Quality Including Necessary Screws Etc. Complete. Only Front Elevation Will Be Measured. 64 Electrical- Wiring 65 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 66 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 67 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 68 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 69 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire 70 Fixtures 71 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socketoutlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Beused In Non Residential Buildings) 72 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Ampsmodular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required 73 Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front Onsurface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25A Modular Sp Mcb, C Curve Including Connections, Painting Etc. Asrequired. 74 Supply, Installation Of Surface Mounted Led Tubelight. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification. Luminaire Shall Be Designed To Emit At Least 3600Nominal Lumens And Efficacy Of Atleast 105 Lumen/Watt And Minimum System Wattageof 30 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Upto 30% Over 25K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. Make - Philips, Crompton, Wipro, Havells 75 Supply And Installation Of Surface/Recess Mounted Led Round/Square Luminaire With Crca Housing Suitable With Fully Diffused Diffuser For General Lighting In Offic Eareas. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K, Cool White Light. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification.Luminaire Shall Be Designed To Emit At Least 1000 Nominal Lumens And Efficacy Ofatleast 105 Lumen/Watt And Minimum System Wattage Of 10 -15 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Up To 30% Over 50K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. For Light Fittings To Be Installed In False Ceiling, All Required Cuttings Shall Be Made And Damages Shall Be Made Good As Per The Direction Of Engineer In Charge. Make-Philips, Crompton, Wipro 76 Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep - 5 Star Rated, 3 Blade Ceiling Fan Complete With 300Mm Down Rod, Canopies,Shackles. 77 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existingmodular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 78 Supplying, Conveyance And Installation Of 3 Blade, 400 Mm Sweep, 1400 Rpm Wall Mount Fan Including Frames And All Mounting Accessories Complete. Recommended Make: Usha/ Havells/ Bajaj / Almonard Or Equivalent 79 Supplying, Conveyance And Installation Of 150 Mm Sweep,1800 Rpm Exhaust Fanincluding Frames And Allmounting Accessories Complete. Recommended Make: Usha/Havells/Bajaj Or Equivalent 80 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. 81 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. 82 Supply, Installation Of 12 Watt Led Bulb. 83 Db And Switchgear 84 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) 85 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door 86 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 87 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 88 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 89 Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existingmcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63Amps 90 Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30Milli Amperes In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required.63 Amps 91 Supplying And Fixing Cable End Boxes (Ip 43) Suitable For Following Single Poleand Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess,Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Spn Mcbdb 92 Cctv And Networking 93 Supply, Conveyance And Installing Of 2Mp Ip Dome/Bullet Camera Having 1/3Progressive Scan True Day And Night Colour Ir Camera Having Effective Pixel Of 2Mp, Video Frame Rate Of 2Mp @30Fps, Minimum Illumination Of 0.01 [email protected], 0Lux@Ir On, 20 M Ir Range, 24 Ir Led, Awb, Agc, Blc, 2D Noise Reduction,With 3.6Mm Board Lense, 12 Vdc, Poe Ip67 Rated Weatherproof Performance. 1 Year Warranty. Make: Bosch/Cp Plus/Honeywell Or Equivalent 94 Supply, Installation And Integration Of 8 Channel Embedded Linux Poe, Nvr (Network Video Recorder), Having Dual Core Embedded Processor, Must Connect 8 Channel Ip Cameras , Should Support Min 2 Sata Hdd Each Of 6Tb And Must Recordvideo Simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smartevent, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(Hevc)/H.264+/H.264, 2 Year Warranty, Image Quality Should Be Maintainedthroughout The Warranty Period. Make: Bosch/Cp Plus/Honeywell Or Equivalent 95 Supply And Installation Of Network Switch. 8 Port Poe Switch 1000Base-T Copper Ethernet Poe+ Connections, 10M/100M/1G Rj-45 Copper Ports, 1000Base-X Fiber Sfp Ports, 8 Port Auto Sensing 10/100/1000 Mbps Poe, Minimum Cpu Memory 512 Mb With 2 Sfp/Combo Ports, Energy Efficient Ethernet (Ieee 802.3Az). Make: Cisco/Cp Plus/ Netgear Or Equivalent 96 Supply And Fixing Of 6U Wall Mounting Rack With Supply And Fixing Of Mounting Brackets For Support Lockable Front Door And Detachable Side Doors, Cable Manager And Pdu Of 4 Or 6 Sockets Including Cooling Fan With Accessories Complete 97 Supply And Installation Of 8Tb Hard Disk 98 Supply And Installation Of Led Color Monitor Of Minimum 32 Inch Screen, Complete,Uhd Display Make: Lg/Samsung/Panasonic Or Equivalent. 99 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable 100 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 101 Supplying And Fixing Rj45 Outlet Including Cover Plate, Keystone Jack And Gang Box Supporting, Connection Etc. As Required 102 Air Conditioning System 103 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Followingcapacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Single Phase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 2 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 104 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Following Capacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Singlephase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4 M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 1.5 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 105 Supply And Installation Of Additional Copper Piping, Cabling From Indoor To Outdoor And Drain Piping For Air Conditioning Unit With Proper Insulation Including All Required On Wall/Above False Ceiling Complete 106 Supply, Installation, Testing And Commissioning Of True On-Line Double Conversion 6 Kva Ups System With 1:1 Crest Factor Single Phase Phase Input – Singlephase Output. Inversion Shall Be Microprocessor Controlled With Instantaneous Sine Wave Control Using Igbt. Ups Shall Have Standard Display Features, Alarms, Safeties, Etc Input Voltage Range : A) Phase & Single Phase With Ground B)Votage Range 190 Vac & 250 Vac C)Input Frequency : 50/60 Hz D)Power Factor : 0.95 Or Above E)Thd : Less Than 5% With Full Load Bypass F) Voltage Range & 200Vac & 240 Vac G) Frequency Range – 45-55 Hz/55-65 Hz Output Voltage Range H)Voltage Range & 200Vac & 240 Vac I)Frequency Range & 50/60 Hz J)Voltage Distortion & Linear Load = 2% K)Voltage Distortion – Nonlinear Load = 5% L)Output Waveform – Pure Sinewave M) Minimum Back Up Time : Continuous 60 Minutes At Full Load Rectifier Shall Be Full Wave Type (Shall Fully Meet The Specified Input Power Requirements) Battery Type: Sealed Lead Acid Maintenance Free Dc Voltage : 24/48/96V Dc System, Battery Nos And Capacity Shall Be Designed For Optimum Storage Space. Make: Liebert Vertiv/Apc By Schneider/Numeric By Legrand 107 Visi Cooler And Refrigerator 108 Supply And Installation Of 260 Litre Refrigerator, Direct-Cool Model With A Minimum 3-Star Bee Rating And Stabilizer-Free Operation. It Shall Use Eco-Friendly Refrigerant (R600A) And Have A High-Efficiency, Low-Noise Compressor. The Unit Shall Include Toughened Glass Shelves, A Vegetable Crisper, Bottle Storage For 2L Bottles, An Internal Freezer Compartment, And A Removable Anti-Bacterial Gasket. It Shall Operate On 230V, 50Hz Ac And Include Standard Accessories Such As An Ice Tray And Egg Tray. The Refrigerator Shall Have 1-Year Comprehensive Warranty And 10-Year Compressor Warranty, With Bis Certification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
46.
Public Administrative Department #11320103 AOC
Tender For Annual Plan-Construction Of Culvert In Tharayilkavala Vavakkad Road Ward 04 Vadakkekkara Gp North Paravur Bp-Npr 166/2025-General Civil Work culvert 2 OD338910/2025-2026:RING BUND Type II putting up ring bund with earth fille gunny bags of top width 0.75m bottom width 1.5 height 1.5 m side and filling in between with earth to form ring bund and maintaining the same leak proof till the complete of the work and clearing the site by dismantling the bund after complete of the work .etc .complete MODIFIED 60.1.2 3 OD338917/2025-2026:Bailing out water using 5HP Pump -Bailing out water with 5HP engine and pump set including conveyance to site and erection , cost of fuel , lubrication oil and other stores , pay of staff etc complete modified 60.2.2 4 2.7.D:Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. (D) Dry Rubble Masonry 5 2.5.2.B:Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. (II) By Mechanical Means (B) Reinforced Cement Concrete 6 OD338916/2025-2026:Supplying and stacking well matured 1/2 split and straight coconut post for driving down throug various strata bellow bed level including cost coveyance labour charges etc complete 7 OD338912/2025-2026::Coconut Pile- Driving down half split coconut pile to lines and levels through variuos strata including all hire charges and labour for fixing , staging platform and all other appliances necessary for pile driving down after pointing the bottom end 8 11.1.1.1:Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil (i) Upto 3 m depth 9 OD338915/2025-2026:DR Packing under Foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at siteModified 60.7.2 10 OD338911/2025-2026:DR with Departmental stone-DRY RUBBLE MASONRY - Dry rubble without concrete leveling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental offices at site 11 11.4.1.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I. P.C.C grade M 10 (i) Nominal mix 1:3:6 12 12.5.3:Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m III. R.C.C grade M 20 13 12.7:Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 14 13.1.2:Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25 15 13.1.1.1:Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I. R.C.C grade M 20 (i) For nominal mix 1:2:4 16 13.3:Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202 17 3.3:Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 18 OD338914/2025-2026:Construction of granular sub-base by providing local material spreading in uniform layers on prepared surface and compacting by ramming to achieve the desired density complete. (ii) Using Gravel mix soil/Quarry muck 19 11.4.2.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II. P.C.C grade M 15 (i) Nominal mix (1:2.5:5) 20 75.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4) 21 3.5.1:Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 22 OD338913/2025-2026:Dry rubble masonry - Dry rubble masonry with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site. (Modified 60.7.1) 23 11.8:Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 24 11.4.4:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 IV. R.C.C grade M 20 25 OD338918/2025-2026:Supplying and fixing granite Name board Please Enable Macros to View BoQ information
Contract Date: Jun 19, 2026 Contract Value : 7.07 Lakh
Government Departments No of Bidders 2
50.
Power #11316393 Technical Bid
Tender For Various Works Related To Installation Of New Distribution Transformers Of Various Capacities As Per E-Tender Specifications On Semi-Turn Basis Under Business Plan 2026-27- 1 Safe Carriage Of Following Materials From Store Centre Or From Any Other Place To The Respective Site Of Work Through The Kachha Pacca Road Including The Work Of Its Loading & Unloading At The Respective Ends, Also Including The Work Of Dragging Etc. And Also Including The Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work As Per Respo Norms. 2 Pcc Pole 8.5 Mtr. Long 3 St Pole 11 Mtr. Long 4 11 Kv Polymeric Disc Insulator 5 11 Kv Disc Fitting 6 11 Kv Polymeric Pin Insulator 7 V-Type Steel Cross Arm 8 Single Phase Transformer 16 Kva 9 11/0.4 Kv Tf 25 Kva 10 11/0.4 Kv Tf 63 Kva 11 11/0.4 Kv Tf 250 Kva 12 11 Kv Tpmo 13 Stay Set Complete 16X1800 14 Acsr Weasal Conductor 15 Acsr Rabbit Conductor 16 Cable Abc 3X50+1X35+1X16 Sq.Mm. 17 Cable Abc 3X95+1X70+1X16 Sq.Mm. 18 Cable Abc 3X120+1X95+1X16 Sq.Mm. 19 Three Phase Distribution Box 20 Supply & Erection Work Of Following Materials:- 21 Ms Channel (Dropper) 100X50X2028Mm (For Fuse Set) 22 Earthing Complete 23 11 Kv Fuse Set 24 Stone Pad 300X300X75Mm 25 Cross Arm Holding Clamp With N&B 26 Ms Channel 125X65X1300 Mm (T-Off) 27 Clamp For Lt T-Off With N&B 28 Holding Clamps For Top Channel Tpmo & Fuse Set With N&B 29 Ms Angle 75X75X6X2028Mm With Clamp N&B (T/F Base) 30 Ms Top Channel (125X65X2240Mm) 31 Lt Fuse Set Protection Unit For 63 Kva Dt With Smc Box 32 Lt Pvc Cable 3.5X70/35 Sq.Mm. 33 Danger Board With N&B 34 Barbed Wire Including Jumper 35 Three Phase Distribution Box 36 Three Phase Distribution Box Clamp 37 Suspension Clamp 38 Pg Clamp 39 Dead End Clamp 40 Eye Hook 41 Concreting Of Pole 42 Al Lug Long Barrel Off Size (Ls) 43 Henley Type Tailless Unit Protection Cubical Pannel 500A, 650V, 250 Kva Dt. 44 Copper L-Piece 50X225X10Mm (Ls) 45 Copper L-Piece 62X225X12Mm (Ls) 46 Lt Xlpe Cable Al 3.5X400 Sq.Mm. 47 Number Plate With N&B 48 Concreting Of Stay 49 F-Bracket For Fitting Top Insulator With N&B 50 Lt Clamp With N&B For Pcc Pole For Neutral 51 Lt Shackle Insulator 100X155Mm 52 Bolt & Nut For Shackle 53 Clamp With Nut Bolt 54 Body And Neutral Earthing Of 250 Kva Distribution Transformers Installed By Digging Of Pit Up To Water Level Depth (Approx. 100’) And Then Inserting 1-1/4\ Dia G.I. Pipe Of \B\ Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 50X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer Including The Cost Of Arrangement Of All Material, Labourer, T&P, Carrier Etc. Required For Proper Completion Of Work. 55 Construction Of 250 Kva Distribution Transformers Of Plinth Of Size 5’X5X4’ Above Ground Level And One Ft. Below The Ground Level Of 9”. After Excavation Of 4” Earth, Brick Ballast Shall Be Provided And Rammering Will Be Done Properly After That A Retaining Wall Of 9” Width By First Class Brick In Ratio 1:4 Of Cement And Sand Shall Be Made. The Earth Shall Be Filled Up To One Ft. Below The Top Of The Plinth. After This Brick Ballast Shall Be Provided Up To 6” From The Earth Level And Proper Rammering Shall Be Done. One No. Jall Of 12 Mm M.S. Tor Shall Be Fixed In The Hollow Of Plinth And One Ft. Thick Rcc In Ratio Of Cement, Sand And Stone Ballast Shall Be Laid On The Top Of The Plinth. The 12 Mm Thick Plastering Shall Be Done All Around The Plinth In 1:4 Ratio Of Cement And Sand. The Contractor Shall Be Responsible To Complete The Work As Per Direction Of Supervising Engineer. It Including The Cost Of All Material, Labour T&P, Carrier Etc. Required For Proper Completion Of Work. 56 Fabrication & Erection Of Fencing And Construction Of Retaining Wall Around Of 250 Kva Transformers.The Complete 11/0.4 Kv Substation Shall Be Provided With Two Meter Height Fencing And Retaining Wall Around The Substation. One No. Gate With Proper Locking Arrangement For Entry Of Personnel Shall Also Be Provided. The Fencing Shall Be Made Of 50X25 Mm X10 Swg Rectangular Welded Mesh Of Wire Mesh In Length. Wire Mesh Shall Be Fixed On Panels Made Of 50X50X6 Mm M.S. Angle. The Wire Mesh On Panels Will Be Supported By 25X3 Mm M.S. Flat On All The Bracings Diagonally And 50X6 M.S. Flat Horizontally At The Center Of The Panel. The Panel Will Be Joined By Bolts & Nuts Of Appropriate Size With Each Other And On The Main Support On Corners Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work. The Painting Of Complete Fencing Shall Also Be Done With One Coat Of Red Oxide Primer And Two Coat Of Synthetic Green Paint. For Construction Of Retaining Wall Around The Fencing, Excavation Of Earth Shall Be Done In Foundation In Ordinary Soil Including Disposal Of Surplus Earth At Some Suitable Distance. The Dimension Of Excavation Shall Be 1M Wide, 0.45 M Deep And Suitable Length As Per Wire Mesh. After Excavation Of Earth A Cement Concreted Pad Shall Be Laid In Foundation. Concreting Shall Be Done With Ist Class Brick Ballast, Coarse Sand And Cement In Proportion Of 8:4:1. First Class Brickwork Shall Also Be Done In Foundation And Super Structure In 1:6 Cement And Coarse Sand Including Necessary Cutting And Moulding Of Bricks In Foundation Depth Of Wall 0.30 M, Thickness Of Wall 0.35 M & Superstructure Brick Work Thickness Of Wall 0.23 M & Depths 0.30 M Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
TenderDetail
Loading tenders