View Bid Results For Erection Of Esp Tenders

We found 208 Bid Results related to erection of esp tenders. You can find Contractor details who won erection of esp tenders along with contract details in Bid awards announcements section.

Filters
Stage
124
68
16
Tender Publishing Platform
20
188
State / UT
19
62
33
22
18
13
13
11
7
6
5
4
4
2
2
2
1
1
1
1
Contract Value
93
24
56
34
Publish Date
2
0
0
0
0
Sector
12
113
49
22
6
5
4
3
2
1
1
1
1
Ownership
5
118
58
22
6
4
Within keyword
Active filters:
Showing 1–5 of 208 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
3.
Agriculture #11421625 AOC
Bids Are invited for Supply And Erection Of Internals Of All Three Fields Of Thermax Make Esp Installed Thermax Make Esp 1 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Shaft Insulator 1016 Mm , Thermax Make Esp 2 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Rapper Coil , Thermax Make Esp 3 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Hypalon Boot , Thermax Make Esp 4 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Worm Gear Cl (Big End) , Thermax Make Esp 5 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Worn Gear Cl (Small End) , Thermax Make Esp 6 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Row Cardbbvb , Thermax Make Esp 7 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Column Card , Thermax Make Esp 8 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Dc Thyristor Unit , Thermax Make Esp 9 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Level Sensor , Thermax Make Esp 10 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Tic , Thermax Make Esp 11 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Rtd , Thermax Make Esp 12 - Supply Of Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler. Hmi , Thermax Make Esp Service 13 - Dismantling, Erection/Fitting, Commisning And Testing Of Field Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler And Macke The Esp Complete Leak Proof. Field Supervision, Tools And Tackle And Free Technical Support/Helth Checkup During The Two Crusing Session (Free Off Cost) Will Be In The Scope Off The Contractor. The Work Includeddismantling, Erection/Fitting, Commisning, Testing And Trial Of Field Internals Of All Three Fields Of Thermax Make Esp Installed At 145Tph/110Kg/Cm2 Capacity Boiler And Making The Esp Complete Leak Proof, Field Supervision, Tools And Tackle And Free Technical Support/Health Checkup During The Two Cruising Sessions (Free Off Cost) Will Be In The Scope Off The Contractor. The Work Include 1. Replacement Of All The Internals Of 3 Fields. 2. Alignment Of All Three Fields. 3. Repairing Of Side Casing, Inlet/Outiet Nozzles, Hopper Vibrator, Doors Etc. Total Quantity : 62
Contract Date: Ref. Documents Contract Value : 43.78 Lakh
Cooperative No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
7.
Agriculture #11333050 Technical Bid
Tender For Fabrication And Erection -- 1 Boiler 2 Dismantling, Fabrication, Erection Of Leak Proof Dampers At Pa, Sa,Fd & Id Fans 3 Dismantling, Fabrication & Erection Of Air Heater Outlet Top Plate. 4 Dismantling, Fabrication, Erection Of Ro Water Storage Tanks Canopy And Railing. 5 Dismantling, Fabrication & Erection Boiler Furnace Ash Discharge Hopper 6 Dismantling, Fabrication & Erection Of Air Heater Outlet Bottom Plate. 7 Dismentling , Fabrication Erection Of Rotory Bagasse Feeder Casing 8 Dismentling , Fabrication Erection Of Belt Conveyor Structure 9 Dismantling, Fabrication & Erection Of S.A. Fan Foundation 10 Dis, Fabrication And Erection Work Of Expansion Bellows At Fd, Id, Esp, Economizer, Aph 11 Ducting Work With Structure 12 Strengthening Of Ducting Of Boiler. 13 Dismantling, Fabrication & Erection Of F.D. Fan Foundation 14 Dis, Fabrication And Erection Of Id Fan Upper & Lower Casing 15 Dis, Fabrication And Erection Of F.D. Fan Upper & Lower Casing 16 Dismantling, Fabrication & Erection Of Drum Type Rotary Bagasse Feeder (With Shaft) 17 Dismantling, Fabrication & Erection Of Screw Feeder 18 Dismantling, Fabrication & Erection Of Screw Feeder Casing. 19 Fabrication & Erection Of Man Hole 24”X24” 20 Dis., Fab & Erecting Of Aph Tubes (Replacement) 21 Dis, Fab & Erection Of R.O Plant Pressure Vessel Stand 22 Fab & Erection Of Fire Fighting Pipe Line Including Valves, Bends, Flange & Support ( Using New Pipeline & Old Drum To Drum Tubes) 23 Travelling Grate Front Side Ash Discharge Plate Dis, Fab & Erection With Structure 24 Fab & Erection Of Travelling Grate Rear Plate Flange (Flange Type ) 25 Fabrication & Erection Of Pneumatic Spreader Assembly From 10 Mm Thk. S.S. Plate With Fabrication & Erection Of Deflector Plate From 20Mm Thk. S.S. Plate With Top & Bottom Flange 26 Dismantling Of Old Pneumatic Spreader Assembly & Internal Deflector Plate 27 Dismantling & Fitting/ Replacement Of Id Fan Impeller 28 Fabrication & Erection Of Id Fan Suction Bend 29 Fabrication & Erection Of Id Fan Suction Cone 30 Fabrication & Erection Of Plate & Spindle Type Damper With Flanges 31 Dismantling, Fabrication & Erection Of Rotary Soot Blower 32 Dismantling, Fabrication & Erection Of Long Retractable Soot Blower 33 Dismantling, Fabrication & Erection Of Economizer L.H.S. & R.H.S From 6 Mm Thk. M.S. Plate With Strengthening From 65 X 65 Angles 34 Fabrication & Erection Of 1.5 Kg/Cm2 Prds, Exhaust & Vapour Pipeline From 10Mm Thk. M. S. Plate 35 Fabrication & Erection Of 1.5 Kg/Cm2 Prds, Exhaust & Vapour Pipeline Drains 36 Dismantling, Overhauling And Fitting 1.5 Kg/Cm2 New Prds(25 Tph) 400 N.B Valve 37 Dismantling, Fabrication & Erection Of New Bagasse Discharge Chute At Return Bagasse Carrier With Gate Arrangement Complete Set In All Respect 38 Fabrication And Erection Of Boiler Outlet/Economizer Hopper 39 Fabrication And Erection Of Water Monitor On Fire Fighting Line 40 Fabrication And Erection Of Fd Fan Suction Cone 41 Replacement Of Travelling Grate Skid Rail 42 Boiling House 43 Platform Work At Various Stations Such As Mill House, Boiler, Turbine, Cranes, Boiling House, C/F House Etc. If Required Anywhere With Structure Strengthening 44 Dismantling , Fabrication & Erection Of Foundation Of Pump & Motor 45 Fitting Of Motor 46 Repairing Of Exhaust Valve 47 Fab & Erection Of Double Filtration System For Quad & Water Inlet Pipe In Pan Condenser. 48 Arrangement For Lifting Of Vaccum Filtered Drums-3 Nos 49 Replacement Of Exhaust And Vapour Valves In The Boiling House. Dis 50 Replacement Of Exhaust And Vapour Valves In The Boiling House Erec- 51 Fabrication Of Electric Motor Cover. 52 Strengthening Of Vapour Pipe Inside & Outside With Angle Iron Rings/ M.S.Plate. 53 Manhole Work In Vapour Pipes/Headers 54 Modification In Bagacillo Chimney 55 Replacement Of Vapour Pipe. A) Dis 56 Replacement Of Vapour Pipe. B) Fab 57 Replacement Of Vapour Pipe. C) Ere 58 Exhaust And Injection Pipeline A) Dis 59 Exhaust And Injection Pipeline B) Fab 60 Exhaust And Injection Pipeline C ) Ere 61 Replacement Of V.Pipe Bends Dis 62 Exhaust & Injection Bends Fab- 63 Exhaust & Injection Bends Erec. 64 Dis,Fab & Ere Of Final Molasses Pipeline 65 Dis,Fab & Ere Of Suction Pipe For Injection, Ct Pump 66 Fab & Erection Of M.S. Vessels, Square & Rectangular Tank 67 Increase Of Shell Height With All The Fitting And Accessories Work. 68 Dis, Fab & Erection Of M.S.Plate Work 69 Dis,Cleaning & Ere Of Pipeline (Juice, Massecuite, Srrup, Molasses Etc) 70 Dis,Fab & Ere Of Coil(Water,Juice,Ammonia,So2Etc) 71 Fab And Erection Of Motor Bed 72 Dis,Fab & Ere Of Nrv For Injection, Turbine, Spray Etc 73 Saveall Of Pan,Quad Dis 74 Saveall Of Pan,Quad Fab 75 Saveall Of Pan,Quad Ere 76 Unloading Of Material From Truck (Ms, Ss, Ci, Acc Etc) 77 Dis, Fab & Ere Of Jay Pipe 78 Fitting Of Baffle Plates 79 Dismantling, Fabrication & Erection Of Belt Conveyor Structure 80 Clarifier Coil Work A) Dismantling 81 Clarifier Coil Work (B) Fabrication 82 Clarifier Coil Work ( C) Erection 83 Dismantling, Fabrication & Erection Of Perforated M.S Plates Of Direct Contact Juice Heaters. 84 Dismantling , Fabrication & Erection Of Strainers Of Injection, Spray , C.T Pumps. 85 Dismantling, Erection (With Alignment) Of Planetary Gear Box Of Crystallizers. 86 Nozzles Of Spray Pond, Condenser. 87 Dismantling (Each Nozzle) 88 Fitting (Each Nozzle) 89 Replacement Of Double Beat Valve 90 Dismantling , Fabrication & Erection Of Exhaust Valve Casing 91 Opening & Fitting Of Juice Heater Covers 92 Dismantling & Fitting Of S.S Tubes In Juice Heater & Evaporator Body 93 Dismantling, Fabrication & Erection Of Mud Mixture Conveyor 94 Dismantling, Fabrication & Erection Of Mud Mixture Casing 95 Dismantling, Fabrication & Erection Of Down Take Umbrella Of Pan 96 Replacement Of 3’’ Coil Of Vertical Crystallizer 97 Gutter Work (Bigger Side Will Be Treated As Dia.) 98 Gutter Work Dismantling 99 Gutter Work Fabrication 100 Gutter Work Erection 101 Jammed Tube Falling Film Evaporator 102 Replacement Of Sluice Valve 103 Fabrication / Strenghting Of Beam, Vessel, Pipe, Channel, Angle Etc. 104 Dis, Fabrication & Erection Of 7 Kg/Cm2 Prds Pipeline 105 Dis, Fabrication & Erection Of 7 Kg/Cm2 Prds Pipeline Drains 106 Replacement Of Readymade Bend 107 Replacement Of Ammonia Pipe Of Pan & Quad 108 Replacing Of Worn Out Brass Zig Zags & S.S Screens Of Vacuum Filter 109 Dismantling, Fabrication & Erection Of M.S Plate ( As Required) 110 Dismantling Of Existing Syrup Sulphitor & Shifting To Scrap Yard 111 Dis., Fab & Erection Of Save All Cone Of Evaporator And Pans 112 Dismantling, Installation And Alignment Of Reduction Gear Box. 113 Dismantling, Fab & Erection Of Agitator 114 Fitting & Replacement Of Batch Type Machine 115 Fitting & Replacement Of Continuous Type Machine 116 Replacement Of Exhaust Balloon 117 Replacement Of Savall Of Quad And Pan 118 Replacement Of Screw Type Arm Of Crystallizer 119 Replacement Of Drive Of Vertical Crystallizer 120 Replacement Of Tube Of Quad And Juice Heater 121 Dis, Fab. & Erection Of Foundation For Clarifier Drive 122 Dismantling, Fabrication & Erection Of Cover Of S400 Semi-Kestner 123 Replacement Of S.S. Pipelines Including Pipe Fittings 124 Replacement Of Seamless Pipeline Including Pipe Fitting 125 Replacement Of Magma Mixer With Arm, Bracket & Gear 126 Dismantling, Fabrication & Erection Of Underground S.S. Pipeline For Condensate Water 127 Dismantling, Fabrication & Erection Of Cone As Per Requirement 128 Modification Of Bagasscillo Cyclone 129 Dismantling, Fabrication, Assembly And Trial Of Mechanical Circulator 130 Modification In Exhaust & Vapour Valve 131 Dismantling, Fabrication & Erection Of Spray Pond Header 132 Dismantling, Fabricaton & Erection Of Basket Housing Cover & Bottom Discharge Chute Of Centrifugal Machine 133 Dismantling, Fabrication & Erection Of Arms Of Clarifier 134 Dismantling, Fabrication & Erection Of Down Tape Of Evaporator Bodies 135 Fabrication & Erection Of Molasses Jacket For Batch Type C/F M/C 136 Hydraulic Testing Of Vertical Crystallizers Complete In All Respects 137 Dismantling, Fabrication & Erection Of Various Stations For Entrainment Catcher 138 Dismantling & Installation Of Super Heater In Boiling House 139 Dismantling & Installation Of Oil Cooler At Turbine 140 Dismantling, Fabrication & Erection Of All High Pressure Line Drains At Turbine 141 Replacement Of Cut Over Valve For Pan 142 Modification Work In Juice Line Below Quad Station 143 Dis., Fabrication & Erection Of Grit Conveyor 144 Dis., Fabrication & Erection Of Sugar Hopper 145 Dis., Fabrication & Erection Of M.S. Tank/Vessel 146 M.S. Pipeline Replacement 147 Dis., Fabrication & Erection Of Vapour/ Exhaust Line From Quad To Pan Station 148 Dismantling And Fitting Vapour/Exhaust Valve 149 Dismantling, Fabrication & Erection Of Bagassecillo Line 150 Dismantling, Fabrication & Erection Of Underground & Outside Pipeline Of All Sizes 151 Boiler/Turbine, Cooling Tower Sugar Godown/Workshop/Store/Cane Unloader & Factory 152 Fab & Erection Of Gate 153 Strengthning Of Tress Beams,Vessel,Pipe With Channel,Angle,Pipe Etc Any Where 154 Fab & Erection Of M.S.Stair/Ladder Single Story 155 Fab & Erection Of M.S.Stair/Ladder Double Story 156 Dismantling, Fabrication & Erection Of Underground And Outside Pipeline Of All Sizes 157 Fabrication & Erection Of Nrv Of Ct Pump 158 Dismantling, Fabrication & Erection Of Turbine Silencer 159 Dismantling, Fabrication & Erection Of Cooling Tower Pipeline From Cooling Tower Of Turbine 160 Misc .Items. 161 M.S Pipeline Per Inch Dia//Ft/Length (A ) Dismentling Of Pipe Line. 162 Upto 1” Dia To 12’ Dia. 163 Above 12” 164 Fabrication Of Pipe Line From M.S.Plate Or Ready-Made Pipe Any Dia. 165 Erection Of Pipe Line Per Inch Dia/Ft/Length (I) Upto 1’ Dia To 166 Erection Of Pipe Line Per Inch Dia/Ft/Length (Ii. Above 12” Dia 167 M.S.Pipe Accessories Work, Dismantling Of Bends, Tee, Reducder, Cross, Elbow, Nipple, Nozzle, Flanged, And Bends. (Per Inch Dia/Ft/Length ) (A) Upto 1”Dia To 12” Dia 168 M.S.Pipe Accessories Work, Dismantling Of Bends, Tee, Reducder, Cross, Elbow, Nipple, Nozzle, Flanged, And Bends. (Per Inch Dia/Ft/Length (Ii.) Above 12” Dia. 169 Fabrication Of Bends, Tee, Reducer Etc.-(P.Inch Dia/Ft) (I) Upto 1”Diato 12” Dia 170 Fabrication Of Bends, Tee, Reducer Etc.-(P.Inch Dia/Ft) ( Ii) Above 12\ Dia.. 171 Erection Of Bends, Tee Etc.(Per Inch Dia/Ft/Length) (I) Upto 1” Dia To 12” Dia 172 Erection Of Bends, Tee Etc.(Per Inch Dia/Ft/Length) Ii) Above 12” Dia 173 Valve Work 174 Dismantling Of Valves, (Per Inch Dia/Pc) Upto 1” Dia To 12” Dia 175 Dismantling Of Valves, (Per Inch Dia/Pc) Above 12” Dia 176 Erection Of Valve 177 Dismantling Of Valves ,(Per Inch Dia/Ft/Length) (I) Upto 1” Dia To 12” Dia 178 Dismantling Of Valves ,(Per Inch Dia/Ft/Length( Ii) Above 12” Dia 179 Plateform Work (Per Sft) 180 I) Dismantling 181 Ii) Fabrication And Erection 182 A) Patch Work With Old Material. 183 B) Patch With New Material . 184 Purling In Work.(Per Rft) (I) Dismantling 185 Fabrication & Erection 186 Cutting Of Old Flange Repairing For Reuse & Fitting 187 Dis, Fabrication And Erection Of Distance Piece 188 Mill House 189 Replacement Of Ms Plate Work, Weak Portion Of Cane Carrier, Chopper, Leveller, Fibrizer, Bagasse Elevator, Mbc,Rbc,Bc Etc A) Dismantling 190 Replacement Of Ms Plate Work, Weak Portion Of Cane Carrier, Chopper, Leveller, Fibrizer, Bagasse Elevator, Mbc,Rbc,Bc Etc B) Fabrication 191 Replacement Of Ms Plate Work, Weak Portion Of Cane Carrier, Chopper, Leveller, Fibrizer, Bagasse Elevator, Mbc,Rbc,Bc Etc C) Erection 192 Hc Flat Replacement Angle, Beam & Channel. 193 Dismantling, Fitting & Alignment Of C-Channel & Teflon Runner Of Rake Carriers . 194 Fabrication & Erection Of Trpf Cover 195 Dismantling, Fabrication & Erection Of Guide(Salami) 196 Dismantling, Fabrication & Erection Of Trough Of Bagasse Carriers 197 Dismantling, Fabrication & Erection Of Bagaescillo Pipe 198 Fabrication & Erection Of Discharge Chute 199 Dismantling, Fabrication & Erection Of Be,Mbc & Rbc Trough 200 Dismantling, Fabrication & Erection Of Be,Mbc & Rbc Side Plate 201 Dismantling, Fabrication & Erection Of Discharge Chute Of Mbc Belt Conveyor 202 Dismantling, Fabrication & Erection Of Foundation Bed Of Pump, Motor, Gear Boxes 203 Fabrication & Erection Of Weak Portion Of Cane Unloader Bridge, Trolley Etc 204 Dismantling,Fabrication & Erection Of Square Bar Of Cane Unloader 205 Dismantling Of Old Rotary Screen Between Mill 1 & Mill 2. 206 Modification In The Mbc Chain As Per New Rbc Belt System. 207 Dismantling Of Complete Rbc Structure. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
9.
Power #11290475 Technical Bid
Tender For Overhauling Of U#5 Ash Handling Plant Bktpp- 2 Replacement/Repairing Of Clinker Grinder ( With Checking & Repairing /Replacement Of Feedsump/ Feedsump Adapter/ Nozzle, Combine Tube, Nozzle Tip, Nozzle Holder Etc. ) 3 Oh Of Feed Gate Along With Feed Gate ( Accessories. ) 4 Servicing/Replacement Of Hydroejector ( Along With Hydro Ejector Nozzle Tips, Throat, Inlet Piece, Nozzle Plate, Nozzle Inlet, Throat Increaser And Intermediate Wear Piece Etc. ) 5 Replacement Of Ba Hopper Looking Glass/ ( Looking Glass Assembly Including Repairing Of Cooling Line & Nozzle. ) 6 Servicing/Replacement Of Knife Gate V/V ( (200Nb/300Nb) At Economizer Hopper & At Discharge Of Clinker Grinder. ) 7 Servicing/Replacement Of 300Nb ( 250Nb Gate/Globe/Butterfly Valve. ) 8 Servicing/Replacement Of 100Nb/150Nb/ ( 200Nb Butterfly/Plug Valve/Gate/Globe Valve. ) 9 Servicing/Replacement Of 15Nb/25Nb/50Nb/ ( 65Nb/80Nb/32Nb Gate/Globe/Butterfly Valve/Ball Valve. ) 10 Trough Seal, Economiser Hopper, Eco ( Seal Box (Including Repair/ Replacement) & Its Drop Pipes And Ba Hopper Checking & Cleaning. ) 11 Oh Of U#5 Esp Area 12 Removal, Physical Inspection, Refitting ( And Replacement Of Esp Fluidising Tiles Including Frame Of Fluidising Tiles (If Required) And Its Pipe Fittings & Accessories To The Fluidising Line. ) 13 Checking, Removal, Refitting, Repairing/ ( Replacement Of Mhv Of Esp & Aph Hopper For Wet Cleaning Including Adapter (Esp Hoppers/Aph Hoppers/ Eco Hoppers).Change Of Seat/Disc Of The Valves As Per Condition. ) 14 Checking, Repairing/Replacement Of ( 10Inch/8Inch Tersg V/Vs. ) 15 Esp Hopper Inside Checking, Cleaning ( Repairing (If Required) And Change Of All Manhole Door Packing Gasket For Wet Cleaning. ) 16 Flushing/Cleaning Of Fluidising Air Line ( Including Replacement Of Damaged Pipe, And Valves, ) 17 Oh Of U#5 Fa Tower Area 18 Bag Filter/Cage Checking, Cleaning & All ( Bag Filter, Cage, Ventury Replacement With Pulse Jet Bar Checking And Repairing, Changing Of Pulsejet Hose And Tightening By Jubilee Clamp If Required. ) 19 Checking, Repairing/Replacement Of Dump ( Gate V/V Of Pct And Its Seal Including Repair Of Pct And Its Seat & With Fixing Of Ss Liner Plate, Dump Gate Gasket, Bearings, Bushes Etc Both For Top Gate And Bottom Gate As Per Requirement. ) 20 Checking, Repairing/Replacement Of Vent ( Equalising Valve Of Pct And Alv Including Change Of Short Piece. ) 21 Physical Inspection & Repairing Of Ish ( Including Change Of Fluidizing Tiles,Repair/ Replacement Of Frame And Checking And Cleaning/ Repair Of Fluidizing Lines And Its Valves And Servicing/ Replacement Of Prv. ) 22 Checking, Repairing/Replacement Of Alv ( Rsv Including Fluidizing Tiles And Repairing/Replacement Of Body Pad And Spool Piece. ) 23 Disposal Of Ish Ash Through Tractor ( To The Ash Dumping Yard. ) 24 Repairing/Replaceemnt Of Collector Tank ( Cylindrical And Conical Portion Including Checking & Replacement Of Impingement Plate, Checking And Clearing Of Seal Box With Minor Repair If Required. ) 25 Repairing/Replaceemnt Of Wetting Head ( Including Checking & Replacement Of Nozzle, Inlet Section, Gaskets, Tail Piece, Outlet Section Etc. ) 26 Oh Of Air Washer (Dry / Wet) Including ( Checking & Replacement Of Nozzles, Gaskets Etc. Or Replacement Of Whole Assembly ) 27 U#5 Pipeline & Fabrication Job 28 Rotation/Replacement Of 8 Inch/10 Inch ( Ci/ Ms Pipe Line Including Bend/Lateral/Spool Piece & T-Joint Below Esp Hopper & Up To Fae Tower, Line Alignment Checking, Repairing/Erection Of Damaged Support, Coupling, Gasket Replacement Etc. ) 29 Replacement Of Vacuum Line, Ms, Ish Vent ( To Esp Duct Ms 200 Nb ) 30 Replacement Of Dry Air Washer Drain Line ( Bahp Valve Station Pipe Line Up To Hydro Ejector Inlet (Ms 150 Nb) ) 31 Replacement Of Ish, Alv Fluidising Line, ( Sealing Line At Bacr, Seal Water Line At Vacuum Pumps, Eco Water Flushing Nozzle Connection (Ms 15 Nb, 25 Nb, 32 Nb, 40 Nb, 50 Nb) ) 32 Replacement Of 8Inch, 10Inch Drc Pipe 33 Replacement Of 10Inch Ci/Drc ( Bend, Tee Etc. ) 34 Fabrication And Erection Of 150Nb,200Nb, ( 250Nb, 300 Nb Ms Bends With Complete Welding. ) 35 Fabrication And Erection Of 32Nb, 40Nb, ( 50Nb, 65Nb, 80Nb, 100Nb , 125 Nb Ms Bends With Complete Welding. ) 36 Replacement Of Eco Slurry To Bah ( (Ms, 300 Nb), Hp & Lp Line In Bah Area, Collection Tank Drain And Overflow Line (Ms 200 Nb, 250 Nb,300 Nb) ) 37 Replacement Of Bah Area Hp Jetting ( Including Inside Bah Jetting Line With Fitting Of Jetting Nozzle, Lp M/U, Trough Seal M/U, Trough Seal Drain (Ms 100 Nb/80 Nb) ) 38 Replacement Of Hp Flushing Line Inside ( Bah With Cutting Of Opening Of Jetting Nozzle, Outside Enclosure Pipes (Ms, 150 Nb) ) 39 Replacement Of Refractory Cooling Header ( Inside And Outside Bah With Cooling Nozzle Inside Bah Area, Individual Connection From Outside Bah Header To Inside Bah Header, Looking Glass Cooling Supply Line, Pct, Alv Vent Lines (Ms 65 Nb, 50 Nb, 25 Nb) )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
17.
Power #11090220 Technical Bid
Tender For Overhauling Of U#3 Ash Handling Plant Bktpp- 1 OH OF U#3 BA HOPPER AREA 2 Replacement/Repairing of Clinker Grinder ( With chute sump and checking/replacement of nozzle, nozzle tip<(>,<)> nozzle holder etc. ) 3 OH of Feed Gate along with Feed Gate ( accessories and including feed gate enclosure box. ) 4 Replacement/Servicing of Jet Pump along ( combine tube, nozzle tip, nozzle holder etc ) 5 Replacement of BA Hopper looking glass/ ( Looking glass assembly. ) 6 Repairing/Checking of BA Hopper manhole ( door. ) 7 Replacement/Servicing of Knife Gate V/V ( 200NB/250NB) at economizer surge hopper & at discharge of Clinker Grinder. ) 8 Replacement/Servicing of 300NB ( 250NB Gate/Globe/Butterfly Valve. ) 9 Replacement/Servicing of 100NB/150NB/ ( 200NB Butterfly/Plug Valve/Gate/Globe Valve. ) 10 Replacement/Servicing of 15NB/25NB/50NB/ ( 65NB/80NB/Gate/Globe/Butterfly Valve/Ball Valve. ) 11 Trough Seal, Economiser Hopper, Eco ( Surge hopper and BA Hopper checking & cleaning. ) 12 OH OF U#3 ESP AREA 13 Removal, physical inspection, refitting ( And replacement (if required) of ESP Fluidising Tiles. ) 14 Checking, removal, refitting, repairing/ ( Replacement of diffuser feeder assembly (below ESP Hopper<(>,<)> 1st & 2nd field) including checking/replacement of diffuser fluidizing tiles for wet cleaning. ) 15 Checking, removal, refitting, repairing/ ( Replacement of Ash Intake Valve of ESP & APH Hopper for wet cleaning. ) 16 Checking, Repairing/Replacement of Air ( Intake V/V of ESP vacuum header. ) 17 Checking, Repairing/Replacement of ( 10inch/9inch TERSG V/Vs. ) 18 ESP Hopper inside cleaning, checking, ( Repairing (if required) and change of all manhole door packing for wet cleaning. ) 19 Flushing/Cleaning of fluidising air line ( Total ESP & FAE Tower. ) 20 OH OF U#3 FA TOWER AREA 21 Bag Filter/Cage checking, Cleaning & all ( Bag Filter replacement with pulse jet bar & body checking and repairing ) 22 Replacement/Repairing of Swing ( Disc V/V of Transfer Hopper. ) 23 Replacement/Repairing of Vent ( Valve, equalising valve of Transfer Hopper and NUVA Feeder. ) 24 Physical inspection, ash Cleaning & ( Repairing of ISH & Fluidizing tiles/gasket replacement ) 25 Disposal of ISH ash through tractor 26 Replacement/Repairing of NUVA ( Feeder diffuser including fluidizing tiles and repairing/replacement of body pad. ) 27 Replacement/Repairing of Collection Tank ( Including checking & replacement of impingement plate and Drop pipe. ) 28 OH of Wetting Head including checking & ( Replacement of nozzle, inlet section, gaskets, tail piece, outlet section etc. ) 29 Replacement/Repairing of Air Washer (Dry ( & Wet) including Checking & replacement of nozzles, gaskets or complete assembly etc. ) 30 PIPELINE & FABRICATION JOB U#3 31 Rotation/Replacement of 8 inch/9 inch ( including bend/lateral/tool piece & T-joint below ESP Hopper & up to FAE Tower, line alignment checking,repairing/erection of damaged support, gasket replacement etc. ) 32 Replacement of 200NB, 250NB, 300NB MS ( Pipe Line. ) 33 Replacement of 100NB, 150NB MS pipe line 34 Replacement of 9inch, 10inch DRC Pipe 35 Replacement of 15NB, 25NB, 40NB, 50NB, ( 65NB, 80NB MS pipe lines. ) 36 Replacement of 9inch/10inch CI/DRC ( Tee/Bend etc. ) 37 Fabrication & Erection of 150NB, 200NB, ( 250NB MS bend. ) 38 Fabrication & Erection of 40NB, 50NB, ( 65NB, 80NB, 100NB MS bend ) 39 HIRING OF HYDRA (CAPACITY 14/20 T) U#3 40 HIRING OF HYDRA (CAPACITY 14/20 T) ( i) Scope includes Operator & Fuel, lubricant etc. and Break down maintenance, if any. ii) The above service of Hydra to be provided throughout the OH period. ) 41 GST Extra as applicable Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
19.
Agriculture #11082237 Technical Bid
Tender for Rate Contract Of Cane Unloader Hydraulic Pumps And Spares , Hydraulic Pump P1m-045-D-002 60 Lpm Max Pressure- 210 Bar Make- Parker With All Necessary Fitting And Other Required EquipmentS. Fitting Of Pumps At Site Is Also In The Scope Of Bidder. , First Motion Worm Shaft For Cane Unloader Lt Gear Box (Detail Of Gear Box Mentioned Below): Detail Of Gear Box: Jr150/6 Ratio: 48:1 Rpm- 960 Hr 400 Make: Niles , Returnable Oil Fiter, Make-Parker Hydraulic Filter Division Metamora, Ohio Usa 43450, Part No.-92616910C,Numerode Pieza-K- 23018, Numer De Piece-Fa57-10 , Air Line Filter Hydrauline supply erection 20-25 U For Cane Unloader , Suction Oil Filter Sc-3-50 For Hydraulic , Cane Unloader Hydraulic Cylinder Repair Kit 50X80 , Rubber Hose Pipe For Hydraulic Cylinder , Make Polyhose, Wp-259 Bar, 3750Psi) Id-3/4, 9-12 , Hydraulic Cylinder For Cane Unloader Garb Suitable For Uttam Make (Both Side Usable) , Strainer For Cane Unloader Grab Tank, Code:Sc3-050, Make: Hydroline , Solenoid Valve (Sov) Model Code: Dg4v5 8Cj.V.Mu.H6.20 Rated Pressure: Pa&B:315 Bar(4568 Psi), T-120 Bar Make: Etn Vickers , Hydex Coupling No-48, Make--Hydex , Hydex Coupling No-48 Sleeve, Make- Hydex , Cane Unloader Lt Bridge Wheel , Cane Unloader Ct Bridge Wheel , Cane Unloader Lt Gear Box Ref No. Jr150/2, Type: Hr400, Rating: 48:1, Speed:960, Make: Niles Engineering , First Motion Worm Shaft For Cane Unloader Lt Gear Box Ref No. Jr150/2, Type: Hr400, Rating: 48:1, Speed:960, Make: Niles Engineering , Cane Unloader Ct Gear Box Ref No. Jr150/8, Type: Vc475, Rating: 42:1, Speed:960, Make: Niles Engineering , First Motion Worm Shaft For Cane Unloader Ct Gear Box Ref No. Jr150/8, Type: Vc475, Rating: 42:1, Speed:960, Make: Niles Engineering , Cane Unloader Grab Gear Box Ref No.Jr118/5, Type: Hr500, Rating: 20.5:1, Speed:960, Make: Niles Engineering , First Motion Worm Shaft For Cane Unloader Grab Gear Box Ref No.Jr118/5, Type: Hr500, Rating: 20.5:1, Speed:960, Make: Niles Engineering , Steel Wire Rope, (6X36) Core, 3/4 Dia, Thk-20Mm, Make-Usha Martin , Break Linner, Width Size: 140Mm X 12Mm Make- Hcl , Hydraulic Hose Pipe Suitable For 5800 Psi With Hydraulic Fittings , Wire Breaded Rubber Hose Pipe, Size: 4 X 14 , Wire Breaded Rubber Hose Pipe, Size: 8 X 14 , Rubber Hose Pipe Flexible 2 At-Ai-4 (Dn6), Hi-Impluse, Din En 853-2Sn, Size-1/4 With Hex Nipple, Working Pressure-400 Bar, Length-1000Mm , Double Steel Wire Braided Flexible Hose Pipe ½ End Connection, 2000Mm Long For Esp Pneumatic Conveying Line.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Contract Date: May 12, 2026 Contract Value : 42.76 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
39.
Educational and Research Institute #10000242 AOC
Tender For Construction Of Ctvs Transplant Ward In Aiims Raipur; 1 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 2 Centering and shuttering including strutting, propping etc. and removal of form for 3 Lintels, beams, plinth beams, girders, bressumers and cantilevers 4 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5 Thermo-Mechanically Treated bars of grade Fe-500D or more. 6 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 7 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. 8 Cement mortar 1 : 3 (1 cement : 3 coarse sand) 9 Providing and fixing 15-17 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, skirtings and similar locations of required size, approved shade, colour and texture laid with epoxy resin based adhesive, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, cleaning, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone slab colour black, Cherry/Ruby red and any size: 10 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 11 40 mm 12 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 13 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 14 250x16 mm 15 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 16 200x10 mm 17 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 18 Twin rubber stopper 19 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 20 Double strip (horizontal type) 21 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 22 Providing and fixing to existing door frames. 23 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 24 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 25 100mm 26 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineerin- charge.(Payment of providing and fixing auto closing hinges shall be paid separately) 27 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge 28 200 mm 29 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. 30 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 32 Size of Tile 600x600 mm 33 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 34 110 mm diameter 35 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mmmade out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, lightfittings, fixtures, smoke detectors etc., wherever required. 36 Main ‘T’ runners to be suspended from ceilingusing G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted withpolyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 37 12 mm cement plaster of mix : 38 1:6 (1 cement: 6 fine sand) 39 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 40 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 41 Two coats 42 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge 43 In cement mortar 44 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 45 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 46 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 47 W.C. pan with ISI marked white solid plastic seat and lid 48 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 49 White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap 50 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 51 Size 600x450x200 mm 52 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 53 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 54 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 55 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 56 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge. 57 50 mm nominal dia Pipes 58 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 59 20 mm nominal dia Pipes 60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 61 25 to 40 mm nominal bore 62 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 63 20 mm nominal bore 64 Providing and fixing uplasticised PVC connection pipe with brass unions : 65 45 cm length, 15 mm nominal bore 66 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 67 15 mm nominal bore 68 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 69 15mm nominal bore 70 Providing and fixing PTMT grating of approved quality and colour. 71 Circular type 100 mm nominal dia 72 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 73 For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron) 74 For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately)Powder coated aluminium (minimumthickness of powder coating 50 micron) 75 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. 76 Pre-laminated particle board with decorative laminationon both sides 77 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketn etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 78 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) 79 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 80 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixedm with water proofing cement compound @ 0.126 kg/sqm. Thislayer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 81 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : 82 Providing and fixing in position Double bay stainless steel (304 grade) scrub station of size 1220x610x1500 mm with automatic sensor & foot operated tap with hot and cold water temperature controller valve and foot operated soap dispenser arrangement of approved make and quality as per the direction of engineer in charge. 83 Providing and fixing 44 mm thick HPL (Hinge Pressure Laminate ) Hermetic Hinge single Leaf Door for civil opening 1800(W)x2100 (H) with S.S. Ball bearing hinges , D Handles , both side key operation dead lock ,View window size 300x300 mm ,sealing gasket, Automatic Drop seal ,door seal and one door closer etc. all complete as per instructions of Engineer In charge. 84 Providing and fixing frosted film of make 3M/Avery/Oracal and of thickness not less than 1 mm over the glass of windows, glass partition etc including cutting of film in a certain design, shape all complete as per the instructions of Engineer In charge. 85 Providing and applying anti microbial epoxy PU flooring of thickness not less than 3 mm, in required colour, patterns etc. having anti skid properties,corners should be uniformly curved, final surface should be non corrosive to biological fluids, detergents etc. all complete as per the instructions of Engineer In charge. The execution of item shall involve activities of cleaning the surface, grinding of the cleaned surface by manual or mechanical means, applying PU flooring primer on the complete surface followed by screed activity to level the complete surface and then followed by applying PU Topcoat. The items to be used shall be of make BASF/ENDURA/MYK failing which the make approved by Engineer-in Charge shall be used. The work is to be executed and completed all as per manufacturers specification and as per direction of Engineer-in Charge. 86 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 87 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 88 Using M.S. angels 40x40x6 mm for diagonal braces 89 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 90 In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete 91 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 92 10 x 120 mm 93 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 94 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) 95 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. 96 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 97 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 98 Providing and fixing 50 mm thick galvanised Puf panel of make Jindal/Tata/JSW on the walls and roof (size, shape and pitch of corrugation as approved by Engineer-in-charge) . The sheet shall be fixed using self drilling /self tapping screws of required size with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces,including cutting to size and shape wherever required, Fixing operations of roof/wall panels shall be completed in all respect as per drawings and manufacturers specifications and under the overall direction of the Engineer-in-charge.Drawing and Layout of Puf Panel is to be submitted by the contractor for the approval of Engineer-in Charge. No separate amount is to be paid by the department to the contractor for drawing/layout 99 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit & accessories as required. 100 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 101 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 102 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 103 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 104 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 105 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 106 5/6 A switch 107 15/16 A switch 108 3 pin 5/6 A socket outlet 109 6 pin 15/16 A socket outlet 110 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 111 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 112 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 113 1 or 2 Module (75mmX75mm) 114 3 Module (100mmX75mm) 115 4 Module (125mmX75mm) 116 6 Module (200mmX75mm) 117 8 Module 118 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 119 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required 120 1 run of cable 121 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 122 100 A,30KA,FPMCCB 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 124 6 way (4 + 18), Double door 125 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 126 Single pole 127 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 128 63 A 129 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 130 63 A TP&N MCB 131 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 132 For 6 way, Double door TPN MCBDB 133 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 134 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm). 135 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required. 136 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 137 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 138 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 139 40 A 140 Supply and laying of3.5*50 Sqmm 1.1 kV grade PVC Sheathed XLPE insulated aluminium armoured cable. 141 Supply and Installation of Exhaust fan suitable for single phase, 230 volts, 50 Hz, AC supply having RPM 1100or better , 300 mm sweep, power input = 35W or less, Air delievery ≥ 700 CFM complete with motor, louvers/ shutters etc. as required in the existing window, includes dismembering of window glass, providing and fixing ACP panel (6mm thickness Aluminium composite panel) framing in place of glass, connection, testing, commissioning etc. as required. 142 Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 143 18 watt 144 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),CM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 145 36 watt 146 Supplying and Installation of clean room recess mounted 600X600 mm, 30-34 watt LED luminaries with lumen efficiancy of >100 lm/W, dimming option, highly specular anodized aluminum reflectors, optical antiglare system, high effiency polycarbonate diffuser with EMC/EMI compliant electronic driver having PF>0.9, THD < 10%, & minimum of 3kV surge/burst protection, complete with 50000 hrs burning for lifetime with supporting data sheet LM-79 & LM-80. Luminaries cover should be made of highly resistant, disinfectant proof laminated, safety glass/acrylic with stylish fine-grained surface. The reflectors should be of high quality, cleanable and non-deteriorating. The Recess frames should be gas tight. The white luminaries body should be made of sheet steel, perfectly powder coated, supplied ready for connection optionally for individual or series circuit with digital electronic control gear in multilamp technology. The Light fitting should be flush with the ceiling and should be removable from top or bottom. Optional pre-set color temperatures or adjust to any CCT in the Productivity Range 3000 K - 5700 K, Dimming Range 10%-100%The LED used in the luminaire shall be only Lumileds, Nichia, Cree, osram & LGIT and hanging with necessary chain etc as required. 147 Supply and Installation of 10 litre capacity Water Geysers in required locationequivalent to Jaquar model- EPM-WHT-V010* 10 liter capacity* Temperature Range:- 25-70ºC or better* Wattage:- 2KW or less* 5 star rating* suitable for single phase, 230 volts, 50 Hz, AC supply. 148 Supplying and Installation of 60 mm thick hermetically sealed single sliding door of ( 2.1 m (H) x 1.5m (W))/(2.1 m (H) x 1.8m (W)). The controller should be capable of being operated by elbow switches/ foot switches as well as touch less sensor. The track should be of Stainless steel/ Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door material should be of HPL colour should match the interior and care should be taken to make the leaf strong and light weight.The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/ Aluminum track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. One should be able to open and close the door effortlessly in case of failure of automatic mechanism. Door opening handle should be of SS (gloss finish), i/c high quality cylindrical lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing, Air tightness 99.99% at a pressure of 100KPa. The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be of 60mm. The inner part of the door should be filled with CFC free polyurethane foam. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. All motors used should be DC brushless motors with essentíal isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed motorized roller blind inside. The starting time after receiving the signal shauld be adjustable between 0.5 to 20 seconds. The complete door assembly should be BIS/ European CE marked/ US FDA approved. Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents.Hermatically Sealed HPL finish DOOR - Automatic with automation,Supply, Installation, Testing of automatic sliding hermatically OT door size of with Double sided wall frame with HPL Plank 400mm.1- Door Profiles- Aluminium Alloy, Grade 6063, Temper T6. Natural Anodized 20 μm.2-PIR. Dimensional stability at +100°C & -25°C (2%max).Density 41Kg/M3 with max deviation of 2kg/m3 as perDIN53420.3- Door Skin- HPL (4mm) both side of door4- Sealing Gasket (Sides and Top)- Replaceable Bulb and Lip design EPDM gasket.5- Sealing Gasket(Bottom)- .Replaceable Special lower sealing EPDM gasket.6-. Vision Panel- Double Glazed IG unit with 5mm tempered glass on both sides. Size = 300 mm x 300 mm x 60mm.7-Lever Handle- Solid AISI 304 Grade Stainless Steel with rubber spring system.8- Rail System- 6mm deep indentations with ‘down and in’ movement at the angle of 45⁰.9- Rollers- Special Grade Self-lubricating PA Bearings: 2X per roller.10-Wall Frame- Aluminium Alloy, Grade 6063, Temper T6 Natural Anodized 20 μm.11- Planks- HPL Planks finished with compact laminates are used to cover the door opening.12- Noise Insulation-28 dB.13- Air Permeability- Air Leakage at ± 100 Pa (pressure difference) = 0.07 m³/h.m. 1-Microprocessor Based controller. (230 Vac, 750 W (max),2- motor, IP65 protection Class, 20 Nm, 3Øx230V. (CE Marked).3- If an obstruction is present and prevents the door from closing, the intelligent automation sense with self reversal function thus eliminatingthe need for an ugly safety strip.4- Additional safety is provided by means of a photo cell fitted across the door opening.5- Variable options for the opening and closing speeds, time delay closing and part opening for pedestrian use and are easy to adjust.6- A self diagnostic coded system makes fault finding simple, reducing expensive down time.7- Magic (Hand) Switch- The spread of infection is controlled by automating the doors with touch less sensors allowing hands free operation.8- Foot switch or Elbow Switch- AISI 304 grade Stainless Steel Foot Switches with high quality inductive sensors.Control: Microprocessor-controlled with Deceleration Measurement System sliding door drive.Power supply: 230 Vac +10% / -15%. Frequency: 47-63Hz . Power Consumption -Maximum : 750 W.Drive :STG motor. Nominal Motor power:90 W, High Torque Motor -20Nm.Microprocessor controlled motor driver. Max. door weight : 350 Kg.Adjustable Speed Control level: 1-9 . Slow speed (V slow) :20(Threshold speed) - 120 mm. / sec.Starting speed (V start) :20(Threshold spped) - 220 mm. / sec. Opening speed (V open) :Threshold speed to 800 mm. / sec. Closing speed (Vclose):Threshold speed to 400 mm. / sec.Pedestrian opening (Half Opening width) :10% - 99% of the available door opening. 149 Supply ,Installation,Testing & Commissioning of factory built cabinet type unit withAl anodised thermal break frame structure injected with minimum 45+-5 mm thick PUFinsulation, GIPanelshallbepowdercoatedfrombothinnerandouterside,evaporationDxcoil expansion valve and corded remote ,Fan section with double width double inlet (DIDW backwards curved) centrifugal fan with Variable speed Fan Motor with VFD, prefilter section with EU3 / G4 class filters & EU-7 Filter(As per Approval of Engineer Incharge ) Dx coil.units shall be with a remote controller as per site requirement. Rating for the AHUs shall be as under - Motor selection (IE-3) to suit the below capacity AHU ratings. AHU shall be mounted on floor/Ceiling Mounted with vibration isolatorsUnit shall be with factory fitted inlet/outlet aluminium Aerofoil dampers. ,Temperature controller ,Door open switch ,pressure drop across filters ,Fan motor over load protector ,Suitable UV System Chamber complete with cable /wiring etc. will be part of this AHU Unit. AHUShouldhave1setofSpareFiltersapartfromCommissioningfiltersfixedinAHU. SuitableCommunication cable from indoor to outdoor is in the scope of agency .Double Skin Heater Bank Chamber comprising of SS 304 spiral strip heaters fitted with Porcelene blocks, Safety air stat & access door for heater rating , UVGI Lamp etc. As per per approved design from Engineer Incharge. AHU connection Kit with Control box (expansion valve ), Control Box,Nitrogen Testing ,Vaccuming , Green Refrigerant Top up .It should be equiped with Controler to control humidity up to 55 % (+-5%).AHU Machine should be Equipped withmotorised Fire Dampers .F.M./S.A Fan 4000 CFM /18 TR(24 HP) X 2 Numbers Coils / 6 ROW coil Full Copper , with two Stage Filter level 10 micron + 5 Micron,ESP-150 MM in WC. Design parameter- Temp.-21+-3 Degree Centigrade , Relative Humidity -55+-5% 150 Supply, Installation, Testing & Commissioning of 22 HP modular type variable refrigerant flow / Variable regrigerant Volume air cooled outdoor units suitable for cooling and heating having all hermatically sealed inverter type scroll compressor, minimum two compressor for above 14 HP modules, microprocessor based controller,top discharge type condensing units, with R410 A refrigerant, Vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Celcius ambient temperature without tripping. The unit shall be suitable to work on 400+/-10%, 3phase , 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required with suitable communication cable. The COP at AHRI Conditions shall not be less than 3.1 and IEER not less than 6.5. 151 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 152 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 153 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 154 Supplying and installing 225 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 155 Supply, installation, balancing and commissioning of Site fabricated Aluminium 0.80 mm rectangular/Circularducting as requiredwith supports as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges (Galvanizing shall be with zinc nominal 120 gm/sqmtr) includes cutting/ dismanteling of wall (if required) and make good the same.Note: Fabrication and jointing of duct shall be as per IS standard and hanging shall be as per SMACNA. 156 Thickness 0.80 mm sheet 157 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. 158 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. 159 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. 160 Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. 161 Fire Damper 162 Actuator 163 Supply and fixing of acoustic lining of AHU wall and ceiling with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to wall and ceiling with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 164 Supplying and fixing of 19 mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 165 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge for Drainage. 166 32 mm nominal dia. 167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit,fitting as required. 168 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 169 Supply ,Fixing and erection of Duct rexin Fire Retardent Canvass Connections with Vibration & Isolation Pad complete as required . 170 Supplying and fixing of MS of (40X40X5)mm stand for condensing (Outdoor) with epoxy painting, unit Size - 1040 mm(L)*440mm(W)*300(H)} . 171 8 SWG (Copper ) Earthing Cable Supply & Fixing complete as required . 172 Supply and fixing of 10 mm Open cellacoustic insulation of supply air duct and plenum with fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per direction of Engineer Incharge AIIMS Raipur. 173 Supplying, fixing, testing and commissioning of Hepa Filter of required Specification withincluding making arrangement for fixing complete as required and as per direction of Engineer-in-charge.Class-14,Efficiency -99.97 174 Supplying, fixing, testing and commissioning of 1 Tile Membrane Surgeon Control Panel of following Specification including making arrangement for fixing with necessary acessaries ,Cable etc. complete as required and as per direction of Engineer-in-charge. 175 Supplying, fixing, testing and commissioningofmotorised damper as required Specification withnecessaryarrangementas per direction of Engineer-in-charge. 176 Supply and fixing ofinsulation work with 6 mm nitrile rubber on existing CPVC drain pipe(32 MM) properly as required. 177 Supply, Installation and Testing of G I Sheet with Galvanized Coating cable tray cover for 225 mm powder coating M.S. cable trays it is highly durable and robust , corrosion and can sustain high load andincluding bolts & nutsall accessories as per specifications etc. as required. 178 Supplying, installation, testing and commissioning of M.V/LT. cubical type totally enclosed dust and vermin proof Floor/Wall mounted Sub Main Distribution Boards suitable for use on 430 V 3 phase 4 wire 50 Hz AC supply, having compartmentalized construction for different incoming/outgoing MCCBs from Approved Make, and separate bus bar & cable alleys , fabricated from min 1.6mm thick CRCA sheet steel of uniform width complete with copper bus bars , MV/LT danger notice plate, Digital type ammeter with Ammeter selector switch , voltmeter with Voltmeter selector switch , LED indicating lamps, cast resin CTs , Confirms to IEC-61439-2, IP-43, Interconnection with suitable capacity copper strips / rods, connection of incoming and outgoing cables with thimbles , smoke/Siemens grey colour stove enamelled painted and having following incoming and outgoing switchgears, 2 earth bolt, removable cable gland plate with spare suitable hole, wall/floor mounted, lockable using hollow standard LT Panel lock key complete as per site required or as approved by Engineer In-charge. A. INCOMER 01 nos. 250amps 35kA TPNL MCCB from Approved Make Thermo-magnetic release type with rotary handle. 01 nos. Digital type single function volt meter to show 0-500V voltage with phase selector switch01 nos. Digital type single function ameter to show amperage with phase selector switch 03 Nos Energy Meter 03 Nos CTs 125/5 ratio 03 LED Indication Light with toggle switches B. OUTGOING 08nos. 40A TPNL MCCB (25 KA) Thermo-magnetic release type. 179 Dismentlingwork of Existing installed duct, FCU, HVAC Pipelines, Starter Panelincluding Welding, Cutting as required as per direction of Engineer Incharge AIIMS Raipur. 180 Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with all connections etc. as required. 181 Supplying,installation,testing&commissioningofmanualcallboxesofMS constructionin surface/recesswithstainlesssteelchain&hammerassembly complete with glass and push button etc. as required. 182 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 184 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered along with battery arrangement for power backup complete with all connections, interconnections as required. 185 4 Zone 186 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 187 Supply and fixing of 4 kg clean agent (HCFC) portable fire extinguisher having pressure guage indicator and arrangement for wall hangingand with warranty for 5 years on complete product. 188 Providing and fixing you are here sign board near entrance and fire reflective sign board, reflective stickers signage for indication at fire doors, fire extinguisher, fire exit with suitable size as per requirement and as per instruction from Engineer In-charge.
Contract Date: Apr 16, 2026 Contract Value : 1.09 Crore
Government Departments No of Bidders 4
Chhattisgarh View Result →
Contract Date: Ref. Documents Contract Value : 2.94 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Jammu and Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 8.25 Lakh
Boards / Undertakings / PSU No of Bidders 5
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 10.50 Lakh
Boards / Undertakings / PSU No of Bidders 7
West Bengal View Result →
50.
Power #9494857 AOC
Tender For Work Contract For Annual Overhauling Of Boiler Non Pressure Part Of 1X500 Mwunit 5, At Sgtps, Mppgcl, Birsinghpur - Overhauling Maintenance Of Id Fans 3 Inspection & Servicing Of Rtl Dodge Sleeve Bearing 4 Internal, Inspection And Cleaning Of Fans 5 Removal And Re-Fixing Of Cones 6 Servicing / Replacement Of I.G.V. System 7 Alignment Of Fan With Motor 8 Replacement Of Rtl Dodge Sleeve Bearing 9 Repairing / Replacement Of Fan Casing 10 Maintenance Of Seal Air Fans 11 Servicing / Replacement Offan Bearing & Coupling 12 Servicing / Replacement Offan Discharge Valve 13 Replacement Of Impeller 14 Replacement Of Expansion Joints 15 Complete Alignment Of Motor & Fan Alongwith Coupling 16 Cleaning Of Dyno Vane Filters 17 Overhauling Maintenance Of F.D. Fans 18 Servicing Of Fan Rotor Assembly 19 Servicing Of Blade Bearing Assembly 20 In-Situ Replacement Of Counterweight & Lever Assembly Of Blade Bearing Assembly 21 Servicing / Replacementof Servo Motor 22 Complete Alignment Of Motor And Fan Alongwith Coupling 23 Servicing & Replacement Of Fan Bearing 24 Overhauling Maintenance Of Pa Fans 25 Servicing / Replacement Of Servo Motor 26 Replacement Of Expansion Joint 27 Complete Alignment Of Motor & Fan Alongwith Coupling 28 Servicing Of Fan Rotor Assembly 29 Servicing Of Blade Bearing Assembly 30 In-Situ Replacement Of Counterweight & Lever Assembly Of Blade Bearing Assembly 31 Servicing & Replacement Of Fan Bearing 32 Cleaning & Servicing Offd & Pa Fan Components 33 Removal Of Top Half Of Fan Casing And Ogv 34 Cleaning Of Complete Fan Including Blades / Silencer 35 Repairing / Replacement Of Fan Casing 36 Scanner Air Fans 37 Servicing Of Scanner Air Fans 38 Overhauling Of Rotary Air Heater 39 Replacement Of Worn Out Plates Of Centre Section By 8 / 10 / 12 / 16 Mm Plate ( He / Ce ) 40 Guide Bearing Checking / Servicing 41 Replacement Of Guide Bearing 42 Support Bearing Checking / Servicing 43 Replacement Of Support Bearing 44 Checking Of Rotor Runout 45 Rotor Leveling 46 Internal Cleaning Of Aph Casing With Hydra Jetting 47 Erection & Removal Of Tempory Scaffolding & Platform At Cold End ( Gas / Air Side ) 48 Maintenance Of Spool Piece 49 Servicing & Replacement Of Trunion / Spoolseal Assy 50 Replacement Of Trunion Shaft And Adaptor Sleeve 51 Repair / Replacement Of Air Sealing Cover Assembly Of Gb / Sb 52 Repair / Replacement Of Spool Assembly 53 Maintenance Of Sealing System Of Air Preheater 54 Leveling Of He Radial Sector Plate 55 Leveling Of Ce Radial Sector Plate 56 Leveling Of Axial Sector Plate 57 Repair / Replacement Of Radial Seals & Rotor Post Seals Of He Or Ce Side And Setting Thereafter 58 Axial Seal Repair / Replacement & Setting 59 By Pass Seal Repair / Replacement & Setting 60 In-Situ Condition Repair Of Sector Plates 61 Modification Adjuster Rod Assembly Of He / Ce Sector Plate / Tracking Spoolassembly Arrangementat Hot End 62 Repair / Replacement Of Damaged, Cover Plates & Seals Between Sector Plates & Center Section 63 Replacement Of Radial Sector Plates 64 Repairing Of Radial Sector Plates 65 Overhauling Of Axial Sector Plates & Its Mechanism 66 Replacement Of ‘T’-Bars He Or Ce Side 67 Replacement / Repair Of Static Seal Assembly ( Hot End / Cold End ) 68 Replacement / Repair Of By Pass Seal Angle Of He / Ce 69 Replacement / Repair Of By Pass Seal Bar Assembly 70 Repair / Replacement Of Rotor Angle 71 Repairing Of Axial Seal Plate 72 Maintenance Of Heating Elements System Of Air Preheaters 73 Steam Washing Of New Baskets 74 High Pressure Hydrajet Cleaning Of Hot / Intermideate / Cold End Heating Elements 75 Replacement Of Hot / Intermideate End Heating Element 76 Reversal Of Hot & Intermediate End Elements 77 Replacement Of Cold End Heating Element 78 Reversal Of Cold End Heating Elements 79 Repair / Replacment Of Cold End Support Lattice 80 Repair / Replacement Of Support Of H.I.E. Baskets 81 Repair / Replacement Of Aph Diaphragms 82 Repairing Of Worn Out Heating Element 83 Maintenance Of Drive System Of Air Preheaters 84 Overhauling Of Drive Gearbox Of Air Preheaters 85 Replacement Of Drive Gearbox Of Air Preheaters 86 Overhauling Of Fluid Coupling 87 Cog Rim Alignment Etc. 88 Repair / Replacement Of Cog Rim Pins ( Sectors ) 89 Alignment Of Drive Motors, Fluid Coupling & Gearboxes 90 Repair / Replacement Of Pinion & Taper Lock Bush / Worthington Hub 91 Replacement / Repairing Of Rack Assembly Of Rotor 92 Maintenance Of Soot Blowing System Of Air Preheaters 93 Overhauling Of Soot Blower Gear-Box 94 Repair / Replacement Of Lance Tubes & Protection Cover / Steam Nozzles 95 Maintenance Works Of Lop System Of Id, Fd & Pa Fans & Air Preheaters 96 Decoupling, Alignment & Coupling Of Lube Oil Pumps 97 Cleaning Of Lube Oil Tank & Replacement Of Lube Oil Offans & Air Preheaters 98 Servicing & Replacement Of Lube Oil Pumps 99 Cleaning / Servicing Of Lube Oil Coolers & Cooling Water Line Valves 100 Repair / Maintenance Of Ductings 101 Cleaning Of Ash From Inside The Duct 102 Repair Of Diversion Plates Without Steel 103 Replacement Of Diversion Plates / Flue Gas Splitter Inside The Duct & I / L Of Esp 104 Repair Of Ducts By Patching 105 With Steel 106 Without Steel 107 Dismantling Of Steel Structures 108 Welding Of Steel Plate, Ms Angle , Ms Flat 109 Gas Cutting Of M.S. Material 110 Replacement Of Bracing Pipes / Protective Angles Inside Duct 111 Replacement Of Beams / Channels Inside Ducts 112 Replacement Or, Refixing Of C&I Tapping Points 113 Repairing Of Aph Hopper 114 Repairing Of Economiser Hopper 115 Repair Of Bof Flue Gas Path 116 Lifting & Transportation Of Coal Dust, Ash Debris And Waste Material 117 Erection And Removal Scaffolding For Duct Repairing 118 Complete Sealing / Blanking Of Duct ( Flue Gas / Air Side ) 119 Section D 120 Maintenance Of Dampers & Gates 121 Cleaning And Inspection Of Mill Hot / Cold Pa Dampers / Guillotine Gates 122 Servicing Of Ca / Ha Dampers Of Mill 123 Repairing / Replacement Of Mill Hot / Cold Pa Dampers Flaps 124 Cleaning, Inspection & Seal Replacement Of Flue Gas / Air Side Dampers / Guillotine Gates 125 Repairing / Replacement Of Flue Gas / Air Side Dampers Flaps Assembly 126 Servicing Of Guillotine Gates Of Esp Inlet & Outlet, Id Fan Outlet 127 Repairing Of Damaged Damper Frames Of Flue Gas / Air Side Ducting System 128 Replacement / Repairing Of Jam Seal Of Damper 129 Fabrication And Replacement Of Dampers Seal 130 Removal & Refiting Of Actuator And Gearbox Of Damper / Guillotine Gate 131 Replacement Of Saph Flue Gas Inlet Damper Assembly ( 9000X3800 Mm ) At The Elevation Of 40 Meter 132 Replacement Of Saph Flue Gas Outlet Damper Assembly ( 9000X4000 Mm ) At The Elevation Of 17 Meter 133 Replacement Of Hot Pa Control Damper Assembly ( 1800X1800 Mm ) At The Elevation Of 7 Meter 134 Replacement Of Seal Air Fan Inlet Gate 135 Installation / Replacement / Repair Ofmetallic Expansion Joint ( Mej ) & Non Metallic Expansion Joint ( Nmej ) 136 Fabrication Of Metallic Expansion Joint 137 Erection Of Metallic Expansion Joint 138 Fabrication Of Support Structure For Mounting Of Nmej / Diversion Plate 139 Erection Of Support Structure For Mounting Of Nmej / Diversion Plate 140 Erection Of Scafolding & Platform For Replacement Of Mej / Nmej 141 Repairing / Replacement Of Protection Cover Of Nmej / Mej 142 Replacement Of Non Metallic Expansion Joints Of Duct And Aph 143 Section E 144 Overhauling Maintenance Of Coal Circuit 145 Complete Servicing Of Gravimetric Raw Coal Feeder Including Replacement Of Head Pulley & Tail Pulley & Coc System 146 Fabrication Of Coal Pipe Flange / Collar 147 Repairing Of Coal Pipe Support Frame 148 Repair / Replacement Of Pipe Above Mdv 149 P.F.Discharge Pipe 150 Replacement Of P.F. Bends. 151 Repairing Of P.F. Bend, Centre Feed Pipes & Straight Pipe By Patch Welding. 152 Changing Of Coal Pipe Victaulic Coupling Gasket Etc. 153 Servicing Of Coal Pipe Hanger Including Repairing. 154 Servicing / Replacement Of Sleeve Coupling Of Coal Pipes 155 Removal, Inspection / Replacement Of Orifices In Pf Pipe Lines 156 Repairing / Replacement Of Coal Burner 157 Replacementof Complete Coal Burner Assembly 158 Replacement / Repair Of Oil / Air Tip 159 Servicing & Refitting Of Oil Burner Assembly 160 Replacement / Repair Of Guide Pipes Of Oil Gun / Scanners / Igniters Inside The Oil Compartment 161 Inspection And Repair Of Guide Plates Of Burners In Coal Nozzle Compartment And Air / Oil Compartment 162 Replacement And Re-Fixing Of Burner Panel Air Seal Plate With Fastener 163 Servicing Of Burner Tilt Mechanism & Arrangement Of All Four Corners Coal Nozzles 164 Repairing Of Burner Panel Inner / Outer Cover 165 Application Of Ceramic Fibre Blankets At Burner Panel & Aph Centre Section 166 Mills 167 Servicing, Rectification Of Feeder Inlet / Outlet Gate 168 Servicing, Rectification Of Bunker Outlet Gatejamming 169 Servicing, Rectification Of Needle Gate Assembly 170 Repairing Of Pf Elbow 171 Replacement Of Pf Elbow / Fie / Moe 172 Replacement / Rotation Of Straight Coal Pipes 173 Fabrication And Erection Of Chute & Pipe With Flanges 174 Repair And Restructuring Of Fan Suction Manifold Canopy 175 Section F 176 Servicing Of Hfo Pump 177 Servicing Of Ldo Pump 178 Servicing Of Hfo Heater 179 Servicing Of Hfo Cooler 180 Servicing / Replacement Of Valves 181 Upto 50 Mm 182 Above 50 Mm 183 Complete Servicing Of Hfo & Ldo Strainer / Filter 184 Replacement Of Tracing Line / Air Pipe 185 Replacement Of Hfo / Steam Pipe
Contract Date: Feb 09, 2026 Contract Value : 5.00 Crore
Government Departments No of Bidders 2
Madhya Pradesh View Result →
TenderDetail
Loading tenders