View Bid Results For Engineering Testing Services Tenders

We found 590 Bid Results related to engineering testing services tenders. You can find Contractor details who won engineering testing services tenders along with contract details in Bid awards announcements section.

Filters
Stage
441
88
61
Tender Publishing Platform
91
499
State / UT
32
84
68
56
49
38
37
32
29
25
18
18
17
16
16
14
14
8
7
6
5
5
4
4
4
3
3
3
2
2
1
1
1
Contract Value
166
56
192
175
Publish Date
1
0
0
0
0
Sector
26
152
126
44
43
31
31
31
28
17
14
9
9
8
7
6
5
5
5
4
4
3
2
2
2
1
1
Ownership
6
212
179
162
33
3
1
Within keyword
Active filters:
Showing 1–12 of 590 tenders matching your filters
1.
Science and Technology #11440503 Technical Bid
Tender for Earth Work , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lif. , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Cement Concrete (Cast In Situ) , Providing And Laying In Position Excluding Cement Concrete Of Level: Specified Grade The Cost Of Centering And Shuttering - All Work Up To Plinth 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources: 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Stone Work , Coursed Rubble Masonry (Second Sort) With Hard Stone In Foundation & Plinth With :Cement Mortar 1:6(1 Cement : 6 Coarse Sand) , Cladding Work , Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge,Granite Work , Wood And P. V. C. Work , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing 40X5 Mm Flat Iron Hold Fast 400 Mm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 300X100x150 Mm 1:3:6 Mix (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). , Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Twin Rubber Stopper , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Wire Mesh / Glazing Of Plain/ Toughened/ Laminated/ Double Glass Unit With / Without High Performance Coatings As Per Design Requirements And Conforming To Is: 3548 & Is: 16231 Shall Be Paid Separately. Note:- Structural Design Proof Checked From A Government Engineering Institute, To Be Provided By The Manufacturer For (I) Sites With Basic Wind Speed 45 M/Sec As Per Is 875 - Part 3 (Ii) Sites With Structure Height More Than 20M For All Wind Speedscasement Window Double Panels With Fixed Mullion With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above) & Sash (39 Mm & Above) X (60 Mm & Above) & Mullion (39 Mm & Above) X (60 Mm & Above). (Height Upto 1.2 Metre). , Steel Work , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Flooring , Providing And Laying Vitrified Tiles In Floor In Diferent Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Double Charge Vitrified Tile Polished Finish Of Size Of Tile 600 X 600 Mm , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Finishing , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Coarse Sand) , 6 Mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Of Reinforced Cement Concrete Slabs And Beams. , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , 12 Mm Thick Plain Cement Mortar Bands In Cement Mortar 1:4 (1 Cement: 4 Fine Sand):Moulded Band , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Itr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade :Two Or More Coats On New Work , French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , Wall Painting With Acrylic Emulsion Paint, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.Two Coats , Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre , Dismantling And Demolishing , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:3:6 Or Richer Mix (Including Equivalent Design Mix) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Aluminium Work , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete.Upto 5 Mm Depth And 5 Mm Width , Market Rate Items , Provinding Precast Cement Concrete Solid Block Masonry Including Hoisting And Setting In Position With Cement Mortar 1:6 (Cement :6 Coarse Sand) Completed As Per The Direction Of Engineer In Charge As Per Site Condition , Providing And Fixing 5 Mm Thick Clear Transparent Acrylic Sheet Of Approved Brand And Manufacture For Fixed Curved Portions In Openings, Including Epdm Rubber/Neoprene Gasket And All Necessary Accessories, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Electrical Work , Laying And Fixing Of One No Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq.Mm (Clamped With 1Mm Thick Saddle) Size On Wall Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 4 X 16 Sq. Mm (25Mm) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Supplying And Fixing Of 4 Way (4 + 12), Double Door Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs As Required . , Supplying And Fixing 6 Way, Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator. , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole And Neutral , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 6 Module (200Mmx125mm) , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15/16 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , 2M Stepped Type Electronic Fan Regulator , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Group Controlled (Looped) Light Point/ Fanpoint/ Exhaust Fan Point/ Call Bell Point (Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit,And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. (Group-C) , Providing And Fixing 6 Swg Dia G.I Wire On Surface Or In Recess For Loop Earthing As Required. , Supplying, Installation, Testing & Commissioning Of Photo Electronic Smoke Detector With Builtin Led And Mounting Base Plate Suitable With Ms Junction Box For Operation On 12V / 24V Complete With All Connections Etc. As Required. , Supplying, Installation, Testing & Commissioning Of Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. , Supplying & Laying Of 2 X 1.5 Sqmm Fire Alarm Armoured Cable, 600/1000V Rated With Annealed Copper Conductor Having Xlpe Insulation, Steel Wire Armouring & Frls Outer Sheath Complete As Required. , Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With Upto 32A, 240 V, C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 32 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Spmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Speed Control Compitable For Electronic Type Regulator And All Remaining Accessories Including Safety Pin,Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Including Fixing Fan Hook In Ceiling Complete As Required. , Supplying, Installation, Testing & Commissioning Of Panel Light 2X2 Ft.,40W Of Powder Coated Die Cast / Extruded Aluminium Body (Thickness ≥ 1.20 Mm) Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency 85%, Operating Voltage Ac 140 270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10% , P. F.≥0.95, Ip20, Cri 80, Ugr (Unified Glare Rating) 19, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With, 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 5700°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. System Lumen Efficacy ≥105 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. , Supplying And Fixing Of 25Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Drawing 1 Run Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended/Surface Mount From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 V, Complete As Required. , Supplying And Fixing Fp Mcb Sheet Steel Enclosure With Din Rail On Surface / Recess Etc. As Required. , Supplying & Fixing Of 4Pole, 63 A Rating, 415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 16Sq.Mm, Aluminium , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 6Sq.Mm, Copper , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,3C X 4 Sq.Mm, Copper , Supply And Laying Of Un Armoured Copper Single Core 10 Sq.Mm Flexible Cable With Annealed Copper Conductor In Suitable Size Hdpe Pipe In Ground/ On Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.4 X 6 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.3 X 4 Sq.Mm , Supply ,Installation, Testing And Commissioning Of 2 Tr/24000Btu Per Hour And Bee-5 Star Rated Wall Mounted Inverter Type Hi Wall Split Cooling Air Conditioner Having Wireless Remote Controller, Hermetically Sealed/Scroll/Rotary Compressor And Eco Friendly Refrigerant,Initial Charge Of Refrigerant,Condensor And Evaporator Coils Of Copper Material, Air Filter With Auto Swing & Auto Restart Features, Suitable For Operation On 230V, Single Phase, 50Hz, Ac Power Supply. The Indoor Unit Shall Be Fixed Rigidly On Wall Using Necessary Frame, The Outdoor Unit Shall Be Mounted On Wall Or Floor Using Suitable Powder Coated Ms Angle Frame As Required. Including Clamps, Bolts, Nuts,Vibrating Dampers, Laying Of 3 Meter Standard Length Of Copper Refrigerant Piping With 3 Meter Pvc Covering Pipe, 3 Meter Drain Piping, Wrapping Tape And Necessary Insulation ,Electrical Flexible Cable Connectivity Between Indoor And Outdoor Unit. Necessary Drilling Of Hole And Finishing The Same To Match For The Surrounding As Required. , Supplying And Fixing Of Frp Box 200Mmx140mmx95mm Size (Nominal Size) On Surface With Hinged Door With Suitable Grounding Copper Bar Link With Holes Fitted Inside The Box Etc. As Required. , Supplying And Fixing Of Dual Rj 45 / Io Outlet On Existing Modular Switch Plate. , Supply,Installation,Testing And Commissioning Of Maintenace Free Earth Pit Of Single Pipe Technology Copper Pipe Of 2000Mm Long (Min), Outer Dia 50 Mm, Wall Thickness 1.2Mm(Min), Filled With Highly Conducting Metallic Compounds With The Permanent Sealing At Both The Ends And Lead Terminal Of 50 X 10 Mm Size At The Top The Length Of The Electrode Shall Be 2000 Mm Excluding The Lead Terminal And The Length Of The Lead Terminal At The Top Shall Be Minimum 50Mm. To Ensure The Moisture Content And Electrical Conductivity, Resistance Lowering Grounding Minerals Shall Be Filled Around The Electrode Of (Min25 Kg) .Heavy Duty Weather Proof Plastic Earth Pit Chamber With Cover Of Dimension 300 Mm Dia (Top), 260 Mm Dia(Bottom) And 300 Mm (Height) Shall Be Used, Numbering Of Pit And Measured Value Written With Weather Proof Painting Or Stickering. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
3.
Petroleum and Natural Gas #11378042 Technical Bid
Tender For Design, Engineering, Manufacturing, Procurement Of Materials And Bought Out Components, Fabrication, Including Start-Up / Commissioning Spares (If Applicable / Recommended By Vendor), Assembly At Shop, Inspection By Tpia, Testing At Manufacturers Works, Packing, Supply Of High Pressure Cl Seal Ring Connectors (Special) To Be Installed At Numaligarh Refinery Limited(Nrl), As Per The Enclosed Tender Standard Specifications, Job Specification, Data Sheets Etc. And Other Codes And Standards Attached Or Referred As Per Material Requisition For Numaligarh Refinery Limited, Golaghat, Assam, India. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) Normal Metal Seated Ball Valve , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) Normal Metal Seated Ball Valve , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-04 (Spec G42G), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-04 (Spec G42G), , 3 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-04 (Spec G42G), , 6 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A351 Gr.Cf8M, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , 2 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-02 (Spec G44M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-02 (Spec G44M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 3 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 4 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-05 (Spec G46M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-05 (Spec G46M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-06 (Spec G47M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-06 (Spec G47M), , 3 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-06 (Spec G47M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 4 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 1 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 1.5 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 2 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 6 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 1 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-04 (Spec G42G), , 1.5 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-04 (Spec G42G), , 3 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-04 (Spec G42G), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 1.5 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 2 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 6 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , .75 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-02 (Spec G44M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-02 (Spec G44M), , .75 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 1 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 1.5 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 3 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 4 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , .75 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-08 (Spec G43M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-08 (Spec G43M), , 1.5 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-08 (Spec G43M), , .75 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , 1 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , 3 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , 4 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , .75 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , 2 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , 6 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , .75 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-02 (Spec G44M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-02 (Spec G44M), , .75 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 1 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 1.5 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 3 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 4 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , 2 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , 3 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , .75 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-05 (Spec G46M), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-05 (Spec G46M), , .75 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-06 (Spec G47M), , 1 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-06 (Spec G47M), , 3 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-06 (Spec G47M), , .75 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 4 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 1 In Paddle Spacer Hub High Pressure Type, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub High Pressure Ends, -, -, -, Refer To Ds-03 (Spec G45M), , 1 In Paddle Blind Hub High Pressure Type, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub High Pressure Ends, -, -, -, Refer To Ds-03 (Spec G45M), , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-060005 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2221001A , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2221001B , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-222106 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222001A , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222001B , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222006 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222007 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-225607 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-263101 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-263102 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-263108 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-275603 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-275604 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-275605 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280003 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280006 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280008 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280019 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2803A01 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2803B01 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890002 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890004 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890005 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890031 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-8935A01 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-8935B01 , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) Normal Metal Seated Ball Valve , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) Normal Metal Seated Ball Valve , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , High Pressure Clamp Connectors(Special) For Detailed Description, Refer Datasheet Tp-1P30A-Pi-Dts-0072. , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-04 (Spec G42G), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-04 (Spec G42G), , 3 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-04 (Spec G42G), , 6 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A351 Gr.Cf8M, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , 2 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-01 (Spec G42M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-02 (Spec G44M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-02 (Spec G44M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 3 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , 4 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-03 (Spec G45M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-05 (Spec G46M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-05 (Spec G46M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-06 (Spec G47M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-06 (Spec G47M), , 3 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-06 (Spec G47M), , .75 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 1 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 1.5 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 4 In Clamp Assembly For High Pressure Hub, Mnf Std, Astm A182 Gr.F304, 2500 Lbs, For Hub High Pressure Ends, As Per Mnf Std, Refer To Ds-08 (Spec G43M), , 1 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 1.5 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 2 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 6 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 1 In Blind Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-04 (Spec G42G), , 1.5 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-04 (Spec G42G), , 3 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F9, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-04 (Spec G42G), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 1.5 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 2 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , 6 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-01 (Spec G42M), , .75 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-02 (Spec G44M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-02 (Spec G44M), , .75 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 1 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 1.5 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 3 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , 4 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-03 (Spec G45M), , .75 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-08 (Spec G43M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-08 (Spec G43M), , 1.5 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-08 (Spec G43M), , .75 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , 1 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , 3 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , 4 In X S-Xxs Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-06 (Spec G47M), , .75 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Hub High Pressure Type, -, Mnf Std, Astm A182 Gr.F347 + Sour Service, 2500 Lbs, Hub Hp Ends, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , 2 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , 6 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-01 (Spec G42M), , .75 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-02 (Spec G44M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-02 (Spec G44M), , .75 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 1 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 1.5 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 3 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 4 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-03 (Spec G45M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , 2 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , 3 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-04 (Spec G42G), , .75 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-05 (Spec G46M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-05 (Spec G46M), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-05 (Spec G46M), , .75 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-06 (Spec G47M), , 1 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-06 (Spec G47M), , 3 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-06 (Spec G47M), , .75 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 1 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 1.5 In X S-160 Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 4 In X S-Xxs Seal Ring, -, Mnf Std, Uns S66286, For Hub High Pressure, 2500 Lbs, -, Refer To Ds-08 (Spec G43M), , 1 In Paddle Spacer Hub High Pressure Type, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub High Pressure Ends, -, -, -, Refer To Ds-03 (Spec G45M), , 1 In Paddle Blind Hub High Pressure Type, Mnf Std, Astm A182 Gr.F321 + Sour Service, 2500 Lbs, Hub High Pressure Ends, -, -, -, Refer To Ds-03 (Spec G45M), , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-060005 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2221001A , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2221001B , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-222106 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222001A , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222001B , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222006 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2222007 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-225607 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-263101 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-263102 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-263108 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-275603 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-275604 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-275605 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280003 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280006 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280008 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-280019 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2803A01 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-2803B01 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890002 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890004 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890005 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-890031 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-8935A01 , Thermowell Along With Clamp Connector Assemblyl . Refer Datasheet For Detailed Description Tp-1P30A-Pi-Dat-0071 1P30-Tw-8935B01
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
5.
Petroleum and Natural Gas #11347516 Technical Bid
Supply Of For Continuous Purging System For Severe-Service Metal-Seated Valves And Critical Measuring Instruments Design, Engineering, Manufacturing, Procurement Of Materials And Bought Out Components, For Purging System As Per Material Requisition For Numaligarh Refinery Limited, Golaghat, Assam, India , Supply Of Hp/Mp/Lp Continuous Purge System With All Required Hardware Including Design, Engineering, Manufacture, Procurement Of Materials And Bought Out Items/Components, Assembly At Shop, Internal Testing, Inspection, Factory Testing And Acceptance (Fat), Packing Etc. Including Supply Of Mandatory And Commissioning Spares, Transportation As Per Mr , Mandatory Spares For Sr No 1.1 : Lumpsum Cost Of Mandatory Spares , Scope As Per Material Requisition. , Transportation: For Indegenious Bidders : Inland Transportation Charges By Road Of All Supplies From Vendor’S Works / Shop To Project Site, Numaligarh Refinery, Golaghat, Asaam/ Rail Transportation Up To Nmgs/Numaligarh Refinery Project Siding. , Unit Rate For Site Supervision (For Installation And Commissioning / Sat) And Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative Shall Be Considered For The Entire Scope Subject To Successful Commissioning For Complete Package, Which Shall Also Be Considered For Commercial Evaluation-Per Diem Charges Upto 8 Hrs On Normal Working Days. ( Bidders To Quoteunit Rate For Diem Charges ) , Per Diem Unit Rate Forsupervision Sevices Of Erection And Commissioning / Performance Testing As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour (Beyond Normal 8 Hours On Normal Working Days). ( Bidders To Quote Over Timerate Per Hour ) , Per Diem Unit Rate Forsupervision Sevices Of Erection And Commissioning / Performance Testing As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour For Work On Weekly Off Days / Holidays (As Applicable To Refinery Site). ( Bidders To Quote Over Timerate Per Hour )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
7.
Railways #11285223 AOC
Supply Of Track Geometry Measurement Systemtrack Geometry Measurement System,Supply, Installation, Commissioning Of Laser Contactless Sensor-Based Track Geometry Meas Urement System (Tgms) As Per Rdso?S Technical Specification No. Tm/Im/341 (January 2015) In Railway?S Spic (As Per Rdso Drawing No. Spic-Ac-9-0-001) (Instead Of The Specific Coach Meant For Trcs To Rdso Dra Wing No. Lwtrc Drg No. Ty90005). [Details Of Stage Inspection At Para 7.Inspection, Testing And Acceptan Ce Of This Tender]. [ Warranty Period: 36 Months After The Date Of Delivery ] ] , Post-Warranty Comprehensive Annual Maintenance Contract (Camc) As Per Clause 3 Of Sr Sp Ecification /Special Condition For Tgms After 2 Years Of Warranty For 5 Years At Annual Discount Rate Of 10%. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Ce/Mas, Sr Tamil Nadu 1.00 Numbers 3 6025Ns07 Optional Non Stock --- No Consignee Inr Spares (Y) Cost Of Set Of Spares With A List Of Spares And Break-Up Of Cost That Will Be Used During The Op Eration And Camc Period. Refer Clause 12 Of Rdso Specification. ] Consignee Ce/Mas, Sr Tamil Nadu 1.00 Set 4 6025Ser02 Essential Non Stock --- Yes Consignee Inr Services (Y) Operation And Maintenance Of Laser Contactless Sensor-Based Track Geometry Measuremen T System (Tgms) During Warranty Period As Per Clause 16 Of Sr Specification/Special Condition For Tgms. ] At (Location) Ce/Mas, Sr Tamil Nadu 1.00 Numbers 5 6025Ser03 Essential Non Stock --- Yes Consignee Inr Services (Y) Page 1 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 Preventive Maintenance And Break Down Maintenance During Warranty Period As Per Clause 11 Of Rdso Specification And As Per Clauses 7,8,12,13 Of Sr Specification /Special Condition For Tgms, I.E. F Or 2 Years From The Date Of Commissioning Of The Tgms. ] At (Location) Ce/Mas, Sr Tamil Nadu 1.00 Numbers 6 6529Ns06 Essential Non Stock --- Yes Rdso-Qa Inr Spares (Y) Set Of Tools Required For Maintenance Of The Machine. Firm To Upload The List Of Tools With Bre Ak-Up Cost. Refer Clause 13 Of Rdso Specification. ] Consignee Ce/Mas, Sr Tamil Nadu 1.00 Set 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 1 Months Of Issue Of Contract, Delivery Of System Completion : Within 6 Months Thereafter Including Design Which Shall Be Submitted With In One (1) Month Of Award Of Loa And Manufacture And Lab Validation Tests Will Be Made Within Three Months By The Firm From The Date Of Approval. 2. The Installation Should Be Completed In One (01) Month, Field Validation Tests And Commissioning Of Tgms Shall Be Completed Within Two (2) Months By The Firm From The Date Of Receipt Of Systems At Ultimate Consignee In Southern Railway. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P Duly Pre-Inspected By Rdso, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions Page 2 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply Should Be As Per Rdso Normal Applicable To Yes Yes Not Allowed Speciï¬Cation Tm/Im/341 And Sr All Bidders Speciï¬Cation/Special Condition For Tgms Attached With This Tender. 2 The Bidder Shall Be Either Manufacturer Or Normal Applicable To Yes Yes Allowed Their Authorized Dealer And Should Have All Bidders (Optional) Supplied, Installed And Commissioned At Least One (01) Laser Contactless Sensor- Based Track Geometry Measurement System (Tgms) Having Following Sub Systems In Last 03 Years. Sub System Contact-Less Laser Sensor And Inertial Principle-Based Track Recording System Having Facility For Measurement Of Track Geometry Parameters Including Curvature & Gauge. The Supplied Track Geometry Measurement Systems (Tgms) Shall Have Capability For Measurement And Recording At Least Up To A Maximum Speed Of 110 Kmph. Or At Least One (01) Similar Integrated Track Monitoring System Should Have Been Supplied By The Firm In The Past And The Same Including The Sub System Shall Be Performing Satisfactorily On Indian Railways Network At Least For Last 02 Years. The Bidder Shall Submit The Performance Certiï¬Cate Issued By The Competent Authority Of The Railway Holding The Itms. 3 The Bidder Shall Submit Signed Copy Of Normal Applicable To Yes Yes Allowed Technical Compliance Statement -Clause- All Bidders (Optional) By-Clause Comments On Technical Speciï¬Cation, Either Conï¬Rming Acceptance Or Indicating Deviations There From. Deviation From The Specification With Reasons Should Be Clearly Indicated. 4 In Case Bidder Quoting As Authorized Normal Applicable To No Yes Allowed Dealer Of Manufacturer Shall Submit Valid All Bidders (Optional) Tender Speciï¬C Authorization Letter From Their Principle Speciï¬C To The Tender. The Bidder Will Submit Authorization Letter From Manufacturer Duly Signed Along With This Offer. 5 (I) The Bidders May Note That Their OffEr Normal Applicable To No No Not Allowed Shall Be Summarily Rejected In Case They All Bidders Fail To Comply Any Of The Above Mentioned Eligibility Criteria. (Ii) The Period For Eligibility Criteria Will Be Counted On The Date Of Opening Of Tender. Page 3 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 6 Preferably Manufacturers Should Normal Applicable To No No Allowed Participate. Firms Who Are Quoting As All Bidders (Optional) Authorised Dealer Of Manufacturer Must Submit Tender Speciï¬C Authorization Letter Issued By The Oem In Their Letter Head Along With Their OffEr, Failing Which Their OffEr Will Be Summarily Rejected. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 7 Firm To Upload Copies Of Purchase Orders, Normal Applicable To Yes Yes Allowed Inspection Certiï¬Cates,Joint Commission All Bidders (Optional) Certiï¬Cate (Completion Report) From Consignee As Proof Of Past Performance. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? 2 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 3 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 4 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 5 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 6 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 7 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders Forpurchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certiï¬Cate) Towards Being Mse? 8 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 9 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 10 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 11 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 12 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 13 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 4 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Date And ϬNishing Date. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) Page 5 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 5 Hsn Code 8608 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst / Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy Is Applicble. Please All Bidders Refer Para 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 6 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Not Allowed Declaration [Land Border Condition] By All Bidders Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Dy.Ce/Track/Hq/Mas,Chennai Central Yard, Bbq, Chennai, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 7 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes No Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. 13 Security Deposit (Sd):- Normal Applicable To Yes Yes Not Allowed (I) Security Deposit Shall Be 5 % Of Total All Bidders Value Of Contract And Shall Be Taken From All Vendors For Contract Value Above Rs. 25 Lakh Subject To The Applicable Exemptions. For Details Please Refer 10.0 Part A Of Sr Tender Conditions Enclosed To This Tender Document. In Case Of Submission Of Security Deposit In The Form Of Bank Guarantee, Please Refer Annexure 5 Of Part-B Of Southern Railway Tender Conditions (Ii) Security Deposit Will Be Released After Completion Of Warranty Period Of 24 Months And Proof Of Submission Of 10% Bg For Camc To Consignee Dy.Ce/Track/Hq/Mas. 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Delivery Schedule. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year, Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Earnest Money Deposit (Emd) : Normal Applicable To Yes Yes Not Allowed 1)Emd Shall Be Deposited By All Vendors All Bidders For Tenders With Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. For The Exemptions And Other Details Please Refer Para 2.0 Part A Of Southern Railway Tender Conditions. 2)In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Part - B Of Southern Railway Tender Conditions. Page 8 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 16 The Tenderers Shall Submit A Copy Of Normal Applicable To Yes Yes Allowed Certiï¬Cate Stating That All Their All Bidders (Optional) Statements/Documents Submitted Along With The Bid Are True And Factual. Standard Format Of Certiï¬Cate To Be Submitted By The Bidder Is Vailable Under Annexure-14 Of The Sr Tender Conditions Document Attached With This Tender. Non Submission Of The Above Certiï¬Cate By The Bidder Shall Result In Summary Rejection Of His/Their Bid. It Shall Be Mandatorily Incumbent Upon The Tenderer To Identify, State And Submit The Supporting Document Duly Self-Attested/ Digitally Signed By Which They/He Is Qualifying The Qualifying Criteria Mentioned In The Tender Document. It Will Not Be Obligatory On The Part Of Tender Committee / Accepting Authority To Scrutinize Beyond The Submitted Document Of The Tenderer As Far As His Qualiï¬Cation For The Tender Is Concerned. For Details Please Refer Para 21 Of Part B Of Sr Tender Conditions Document Attached With This Tender. 17 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Rdso All Bidders (Mandatory) Speciï¬Cation And Also Sr Speciï¬Cation/Special Condition For Tgms Mentioned In Bid Documents And Drawings Enclosed Along With This Tender, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 18 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Sum Of All Bidders Cost Of The Equipment With All Accessories, Cost Of Tools, Cost Of Operation And Maintenance, Cost Of Preventive And Break Down Maintenance, And The Cost Towards Comprehensive Annual Maintenance Contract For 5 Years (With Npv Factor At Discount Of 10% Per Year) Following Free Comprehensive Warranty For 2 Years. (Excluding Cost Of Optional Spares). 19 Firm To Upload List Of Spares With Cost Normal Applicable To Yes Yes Allowed Breakup That Will Be Used During All Bidders (Optional) Operation And Camc Period. 20 Firm To Upload List Of Tools Required For Normal Applicable To Yes Yes Allowed Maintenance Of The Machine With Cost All Bidders (Optional) Breakup. 21 Please Enter The Percentage Of Local Normal Applicable To Yes Yes Allowed Content In The Material Being OffEred. All Bidders (Mandatory) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. Page 9 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 22 (I) Firms Claiming To Be Class-I/Ii Local Normal Applicable To Yes Yes Allowed Supplier On The Basis Of Self Certiï¬Cation All Bidders (Mandatory) Of Local Content Are Required To Upload Along With Their OffEr A Self Certiï¬Cate Of Percentage Of Local Content In The Product OffEred. (Please Refer Para 16.0 Of Part B Of Sr Tender Conditions). (Ii) Please Enter The Percentage Of The Local Content In The Material Being Offered. Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Condition. 23 Bidders Must Quote On ϬRm Price Basis Normal Applicable To Yes Yes Not Allowed Only As Price Is Not Subject To Any All Bidders Variation. OffErs Quoted With Price Variation Clause (Pvc) Will Be Considered Unresponsive And Will Be Summarily Rejected. 24 Firm Should Provide Training For 4 Railway Normal Applicable To Yes Yes Not Allowed Oï¬Ƒcials For 4 Weeks At Their Premises. For All Bidders Details Refer Para 14.0 Of Rdso Speciï¬Cation And Para 6 Of Sr Specification/Special Condition For Tgms. 25 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Dy. Cmm/Tr/Sr At All Bidders 9003060774. 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Cte/Sr/Mas. Dy. Ce/Tracks/Mas Mobile No. 9003060226. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost, If Any. 3 Tenderers May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 10 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 1 Inspection Will Be By Rdso With 3 Stages Normal Applicable To No No Not Allowed Of Inspection As Follows: All Bidders Stage 1 : Pre-Dispatch Inspection At Oem Works By Staff From Concerned Directorate Of Rdso Stage 2 : Installation Veriï¬Cation By Staff Of Concerned Directorate Of Rdso/ Engineering Oï¬Ƒcials Nominated By Cte/Southern Railway Stage 3 : Commissioning & Performance Run By Engineering Oï¬Ƒcials Nominated By Cte/Southern Railway 2 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 3 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 4 Machine Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning Or 36 Months From The Date Of Supply Whichever Is Earlier. 5 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 6 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 7 In Case, ϬRm Is Submitting Security Normal Applicable To Yes Yes Not Allowed Deposit In The Form Bank Guarantee, It Is All Bidders To Be In Favour Of Fa&Cao/Ws/Per. Format For Bank Guarantee Is Available In Uploaded Document Conditions For Electronic Tenders . Contract Will Be Executed By President Of India Acting Through Principal Chief Materials Manager. Signature, Name And Address Of Two Witnesses Is Mandatory. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Not Allowed As Per Rdso Speciï¬Cation And Sr All Bidders Speciï¬Cation/Special Condition For Tgms Attached With This Tender. Tenderers Are Required To Submit Complete Details Including Values, Write-Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Any Contradiction, Between Rdso Speciï¬Cation And Sr Speciï¬Cstion/Special Condotion For Tgms, Clauses In Sr Speciï¬Cation/Special Condition For Tgms Will Supersede Rdso Specification. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. Page 11 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To The 3 Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The Offer 5 And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In The 8 Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After The 9 Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description 1 5535860.Pdf Rdso Specification Tm/Im/341 2 5532490.Pdf Sr Tender Conditions 3 5530801.Pdf Irs Conditions 4 5530787.Pdf Sr Specification/Special Condition For Tgms 7. Responsiveness S.No. Description 3.1 I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. Scope Of Supply (For Main Item): As Per Clause-2 Of Rdso Speciï¬Cation No.Tm/Im/341 Enclosed With This 3 Tender. Scope Of Supply (For Operation And Maintenance, Camc ) As Per Sr Speciï¬Cation/Special Condition For Tgms Enclosed With This Tender. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Page 12 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 Digitally Signed By Dy.Cmm/Traction ( A N Veeraraghavan ) , Cost Of Set Of Spares With A List Of Spares And Break-Up Of Cost That Will Be Used During The Op Eration And Camc Period. Refer Clause 12 Of Rdso Specification. ] , Operation And Maintenance Of Laser Contactless Sensor-Based Track Geometry Measuremen T System (Tgms) During Warranty Period As Per Clause 16 Of Sr Specification/Special Condition For Tgms. ] At (Location) Ce/Mas, Sr Tamil Nadu 1.00 Numbers 5 6025Ser03 Essential Non Stock --- Yes Consignee Inr Services (Y) Page 1 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly , Preventive Maintenance And Break Down Maintenance During Warranty Period As Per Clause 11 Of Rdso Specification And As Per Clauses 7,8,12,13 Of Sr Specification /Special Condition For Tgms, I.E. F Or 2 Years From The Date Of Commissioning Of The Tgms. ] At (Location) Ce/Mas, Sr Tamil Nadu 1.00 Numbers 6 6529Ns06 Essential Non Stock --- Yes Rdso-Qa Inr Spares (Y) Set Of Tools Required For Maintenance Of The Machine. Firm To Upload The List Of Tools With Bre Ak-Up Cost. Refer Clause 13 Of Rdso Specification. ] Consignee Ce/Mas, Sr Tamil Nadu 1.00 Set 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 1 Months Of Issue Of Contract, Delivery Of System Completion : Within 6 Months Thereafter Including Design Which Shall Be Submitted With In One (1) Month Of Award Of Loa And Manufacture And Lab Validation Tests Will Be Made Within Three Months By The Firm From The Date Of Approval. 2. The Installation Should Be Completed In One (01) Month, Field Validation Tests And Commissioning Of Tgms Shall Be Completed Within Two (2) Months By The Firm From The Date Of Receipt Of Systems At Ultimate Consignee In Southern Railway. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P Duly Pre-Inspected By Rdso, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions Page 2 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply Should Be As Per Rdso Normal Applicable To Yes Yes Not Allowed Speciï¬Cation Tm/Im/341 And Sr All Bidders Speciï¬Cation/Special Condition For Tgms Attached With This Tender. 2 The Bidder Shall Be Either Manufacturer Or Normal Applicable To Yes Yes Allowed Their Authorized Dealer And Should Have All Bidders (Optional) Supplied, Installed And Commissioned At Least One (01) Laser Contactless Sensor- Based Track Geometry Measurement System (Tgms) Having Following Sub Systems In Last 03 Years. Sub System Contact-Less Laser Sensor And Inertial Principle-Based Track Recording System Having Facility For Measurement Of Track Geometry Parameters Including Curvature & Gauge. The Supplied Track Geometry Measurement Systems (Tgms) Shall Have Capability For Measurement And Recording At Least Up To A Maximum Speed Of 110 Kmph. Or At Least One (01) Similar Integrated Track Monitoring System Should Have Been Supplied By The Firm In The Past And The Same Including The Sub System Shall Be Performing Satisfactorily On Indian Railways Network At Least For Last 02 Years. The Bidder Shall Submit The Performance Certiï¬Cate Issued By The Competent Authority Of The Railway Holding The Itms. 3 The Bidder Shall Submit Signed Copy Of Normal Applicable To Yes Yes Allowed Technical Compliance Statement -Clause- All Bidders (Optional) By-Clause Comments On Technical Speciï¬Cation, Either Conï¬Rming Acceptance Or Indicating Deviations There From. Deviation From The Specification With Reasons Should Be Clearly Indicated. 4 In Case Bidder Quoting As Authorized Normal Applicable To No Yes Allowed Dealer Of Manufacturer Shall Submit Valid All Bidders (Optional) Tender Speciï¬C Authorization Letter From Their Principle Speciï¬C To The Tender. The Bidder Will Submit Authorization Letter From Manufacturer Duly Signed Along With This Offer. 5 (I) The Bidders May Note That Their OffEr Normal Applicable To No No Not Allowed Shall Be Summarily Rejected In Case They All Bidders Fail To Comply Any Of The Above Mentioned Eligibility Criteria. (Ii) The Period For Eligibility Criteria Will Be Counted On The Date Of Opening Of Tender. Page 3 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 6 Preferably Manufacturers Should Normal Applicable To No No Allowed Participate. Firms Who Are Quoting As All Bidders (Optional) Authorised Dealer Of Manufacturer Must Submit Tender Speciï¬C Authorization Letter Issued By The Oem In Their Letter Head Along With Their OffEr, Failing Which Their OffEr Will Be Summarily Rejected. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 7 Firm To Upload Copies Of Purchase Orders, Normal Applicable To Yes Yes Allowed Inspection Certiï¬Cates,Joint Commission All Bidders (Optional) Certiï¬Cate (Completion Report) From Consignee As Proof Of Past Performance. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? 2 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 3 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 4 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 5 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 6 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 7 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders Forpurchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certiï¬Cate) Towards Being Mse? 8 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 9 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 10 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 11 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 12 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 13 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 4 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Date And ϬNishing Date. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) Page 5 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 5 Hsn Code 8608 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst / Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy Is Applicble. Please All Bidders Refer Para 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 6 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Not Allowed Declaration [Land Border Condition] By All Bidders Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Dy.Ce/Track/Hq/Mas,Chennai Central Yard, Bbq, Chennai, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 7 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes No Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. 13 Security Deposit (Sd):- Normal Applicable To Yes Yes Not Allowed (I) Security Deposit Shall Be 5 % Of Total All Bidders Value Of Contract And Shall Be Taken From All Vendors For Contract Value Above Rs. 25 Lakh Subject To The Applicable Exemptions. For Details Please Refer 10.0 Part A Of Sr Tender Conditions Enclosed To This Tender Document. In Case Of Submission Of Security Deposit In The Form Of Bank Guarantee, Please Refer Annexure 5 Of Part-B Of Southern Railway Tender Conditions (Ii) Security Deposit Will Be Released After Completion Of Warranty Period Of 24 Months And Proof Of Submission Of 10% Bg For Camc To Consignee Dy.Ce/Track/Hq/Mas. 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Delivery Schedule. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year, Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Earnest Money Deposit (Emd) : Normal Applicable To Yes Yes Not Allowed 1)Emd Shall Be Deposited By All Vendors All Bidders For Tenders With Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. For The Exemptions And Other Details Please Refer Para 2.0 Part A Of Southern Railway Tender Conditions. 2)In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Part - B Of Southern Railway Tender Conditions. Page 8 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 16 The Tenderers Shall Submit A Copy Of Normal Applicable To Yes Yes Allowed Certiï¬Cate Stating That All Their All Bidders (Optional) Statements/Documents Submitted Along With The Bid Are True And Factual. Standard Format Of Certiï¬Cate To Be Submitted By The Bidder Is Vailable Under Annexure-14 Of The Sr Tender Conditions Document Attached With This Tender. Non Submission Of The Above Certiï¬Cate By The Bidder Shall Result In Summary Rejection Of His/Their Bid. It Shall Be Mandatorily Incumbent Upon The Tenderer To Identify, State And Submit The Supporting Document Duly Self-Attested/ Digitally Signed By Which They/He Is Qualifying The Qualifying Criteria Mentioned In The Tender Document. It Will Not Be Obligatory On The Part Of Tender Committee / Accepting Authority To Scrutinize Beyond The Submitted Document Of The Tenderer As Far As His Qualiï¬Cation For The Tender Is Concerned. For Details Please Refer Para 21 Of Part B Of Sr Tender Conditions Document Attached With This Tender. 17 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Rdso All Bidders (Mandatory) Speciï¬Cation And Also Sr Speciï¬Cation/Special Condition For Tgms Mentioned In Bid Documents And Drawings Enclosed Along With This Tender, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 18 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Sum Of All Bidders Cost Of The Equipment With All Accessories, Cost Of Tools, Cost Of Operation And Maintenance, Cost Of Preventive And Break Down Maintenance, And The Cost Towards Comprehensive Annual Maintenance Contract For 5 Years (With Npv Factor At Discount Of 10% Per Year) Following Free Comprehensive Warranty For 2 Years. (Excluding Cost Of Optional Spares). 19 Firm To Upload List Of Spares With Cost Normal Applicable To Yes Yes Allowed Breakup That Will Be Used During All Bidders (Optional) Operation And Camc Period. 20 Firm To Upload List Of Tools Required For Normal Applicable To Yes Yes Allowed Maintenance Of The Machine With Cost All Bidders (Optional) Breakup. 21 Please Enter The Percentage Of Local Normal Applicable To Yes Yes Allowed Content In The Material Being OffEred. All Bidders (Mandatory) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. Page 9 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 22 (I) Firms Claiming To Be Class-I/Ii Local Normal Applicable To Yes Yes Allowed Supplier On The Basis Of Self Certiï¬Cation All Bidders (Mandatory) Of Local Content Are Required To Upload Along With Their OffEr A Self Certiï¬Cate Of Percentage Of Local Content In The Product OffEred. (Please Refer Para 16.0 Of Part B Of Sr Tender Conditions). (Ii) Please Enter The Percentage Of The Local Content In The Material Being Offered. Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Condition. 23 Bidders Must Quote On ϬRm Price Basis Normal Applicable To Yes Yes Not Allowed Only As Price Is Not Subject To Any All Bidders Variation. OffErs Quoted With Price Variation Clause (Pvc) Will Be Considered Unresponsive And Will Be Summarily Rejected. 24 Firm Should Provide Training For 4 Railway Normal Applicable To Yes Yes Not Allowed Oï¬Ƒcials For 4 Weeks At Their Premises. For All Bidders Details Refer Para 14.0 Of Rdso Speciï¬Cation And Para 6 Of Sr Specification/Special Condition For Tgms. 25 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Dy. Cmm/Tr/Sr At All Bidders 9003060774. 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Cte/Sr/Mas. Dy. Ce/Tracks/Mas Mobile No. 9003060226. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost, If Any. 3 Tenderers May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 10 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 1 Inspection Will Be By Rdso With 3 Stages Normal Applicable To No No Not Allowed Of Inspection As Follows: All Bidders Stage 1 : Pre-Dispatch Inspection At Oem Works By Staff From Concerned Directorate Of Rdso Stage 2 : Installation Veriï¬Cation By Staff Of Concerned Directorate Of Rdso/ Engineering Oï¬Ƒcials Nominated By Cte/Southern Railway Stage 3 : Commissioning & Performance Run By Engineering Oï¬Ƒcials Nominated By Cte/Southern Railway 2 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 3 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 4 Machine Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning Or 36 Months From The Date Of Supply Whichever Is Earlier. 5 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 6 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 7 In Case, ϬRm Is Submitting Security Normal Applicable To Yes Yes Not Allowed Deposit In The Form Bank Guarantee, It Is All Bidders To Be In Favour Of Fa&Cao/Ws/Per. Format For Bank Guarantee Is Available In Uploaded Document Conditions For Electronic Tenders . Contract Will Be Executed By President Of India Acting Through Principal Chief Materials Manager. Signature, Name And Address Of Two Witnesses Is Mandatory. Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Not Allowed As Per Rdso Speciï¬Cation And Sr All Bidders Speciï¬Cation/Special Condition For Tgms Attached With This Tender. Tenderers Are Required To Submit Complete Details Including Values, Write-Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Any Contradiction, Between Rdso Speciï¬Cation And Sr Speciï¬Cstion/Special Condotion For Tgms, Clauses In Sr Speciï¬Cation/Special Condition For Tgms Will Supersede Rdso Specification. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. Page 11 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To The 3 Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The Offer 5 And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In The 8 Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After The 9 Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description 1 5535860.Pdf Rdso Specification Tm/Im/341 2 5532490.Pdf Sr Tender Conditions 3 5530801.Pdf Irs Conditions 4 5530787.Pdf Sr Specification/Special Condition For Tgms 7. Responsiveness S.No. Description 3.1 I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. Scope Of Supply (For Main Item): As Per Clause-2 Of Rdso Speciï¬Cation No.Tm/Im/341 Enclosed With This 3 Tender. Scope Of Supply (For Operation And Maintenance, Camc ) As Per Sr Speciï¬Cation/Special Condition For Tgms Enclosed With This Tender. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Page 12 Of 13 Run Date/Time: 16/09/2025 16:12:37Stores/Southern Rly Tender Document Tender No 16255013 Closing Date/Time 13/10/2025 14:30 Digitally Signed By Dy.Cmm/Traction ( A N Veeraraghavan ) , Set Of Tools Required For Maintenance Of The Machine. Firm To Upload The List Of Tools With Bre Ak-Up Cost. Refer Clause 13 Of Rdso Specification. ]
Contract Date: Jun 15, 2026 Contract Value : 7.62 Crore
Government Departments No of Bidders 1
8.
Petroleum and Natural Gas #11278216 Technical Bid
Supply Of Chain Pulley Blocks Design, Engineering, Procurement, Fabrication, Inspection, Testing, Transportation, And Supply Of Chain Pulley Blocks As Per Material Requisition , 6 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc.) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 1 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc.) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 6 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc.) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 4.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 4.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 10 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 7.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 1.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 1.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 2 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 1 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 2 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 1 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 3.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 5.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 1 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 1 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 2.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 4 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 0.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 4 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 0.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 2.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 3.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 3.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 3.5 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 3 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , 3 Mt, Cp Block Assembly With Mounting Hook (Hand Chain & Load Chain Mechanism, Top And Bottom Hooks Block, Chain Guide, Automatic Ratchet And Pawl Type Load Brake, Idler Wheel, Etc) As Per Particular Technical Specification For Chain Pully Blocks As Per Annexure - 1 Of Tp-1P30a-Me-Sos-0047_D1, Attached With The Mr. , Per Diem Rate For Supervision Sevices Of Installation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Per Diem Charges Upto 8 Hrs On Normal Working Days. ( Bidders To Quoteunit Rate For Diem Charges ) , Unit Rate Forsupervision Services Of Installation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour (Beyond Normal 8 Hours On Normal Working Days). ( Bidders To Quote Over Timerate Per Hour ) , Unit Rate Forsupervision Sevices Ofinstallation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour For Work On Weekly Off Days / Holidays (As Applicable To Refinery Site). ( Bidders To Quote Over Timerate Per Hour ) => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
10.
Petroleum and Natural Gas #11260872 Technical Bid
Supply Of Multi-Type Flowmeters Design, Engineering, Procurement, Fabrication, Inspection, Testing, Transportation, And Supply Of Multi-Type Flowmeters As Per Material Requisition , Ultrasonic Flowmeter (Clamp On) , Ultrasonic Flowmeter (Clamp On) , Ultrasonic Flowmeter (Clamp On) , Coriolis Flowmeter , Coriolis Flowmeter , Coriolis Flowmeter , Coriolis Flowmeter , Coriolis / Clamp-On Ufm / Inline Ufm / Vortex Flowmeter , Coriolis / Clamp-On Ufm / Inline Ufm / Vortex Flowmeter , Coriolis / Clamp-On Ufm / Inline Ufm / Vortex Flowmeter , Per Diem Rate For Supervision Sevices Of Installation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Per Diem Charges Upto 8 Hrs On Normal Working Days. ( Bidders To Quoteunit Rate For Diem Charges ) , Unit Rate For Supervision Services Of Installation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour (Beyond Normal 8 Hours On Normal Working Days). ( Bidders To Quote Over Timerate Per Hour ) , Unit Rate Forsupervision Sevices Ofinstallation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour For Work On Weekly Off Days / Holidays (As Applicable To Refinery Site). ( Bidders To Quote Over Timerate Per Hour ) => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
11.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
13.
Defence #11225622 AOC
Bids Are invited for Consultancy And Soil Investigation Soil Investigation 1 - Carrying Out Soil Investigation Incl All Necessary T&P Labour And Required Materials Etc All Field Work Collection And Interpretation Of Data And Laboratory Studies And Submission Of Report Comprising Of The Following , Soil Investigation 2 - Mobilization Of Plants And Equipment Including Men And Materials As Required At Site Of Soil Investigation Setting Of Boring Drilling As Required And Demobilization Of Plants And Equipments On Completion Of Work Etc Complete Which Includes Conveyance Of S Le Collected To Testing Lab As Reqd For The Purpose Of Testing , Soil Investigation 3 - Boring 150Mm Dia Bore Holes To Any Depth Through Following Type Of Strata , Soil Investigation 4 - Any Type Of Soil , Soil Investigation 5 - Soft Rock , Soil Investigation 6 - Hard Rock , Soil Investigation 7 - Collection Of Undisturbed Soil S Les At Every 3M Intervals Or At Any Change Of Strata In 100Mm Bore Thin Walled Tube Including Waxing Sealing Packing Transporting To The Lab , Soil Investigation 8 - Carrying Out Standard Penetration Test Spt As Per Is 2131 Including Collection Of Disturbed Soil S Les In Bore Holes At Every 5M Depth Or At Any Change Of Strata And Submit The Report With All Requisite Data , Soil Investigation 9 - Conducting Necessary Test On All Collected S Les Of Each Bore Hole Which Includes The Determination Of , Soil Investigation 10 - Atterberg Limits Natural Moisture Content Wet And Dry Density Soil Particle Size Using Sieve Hydrometer Analysis And Shear Strength Test Unconfined Compression V Tri-Axial Shear Test C & Determination Shrinkage Limit Consolidation Test Incl Pre-Consolidation Pressure Specific Gravity Test For Sand Rock Crushing Strength Of Rock S Le Permeability Test Testing Of Water S Le Including Ph Determination 02 S Le Free Swelling Index Soluble Salt Content Chloride And Sulphate Shear Strength Test Un Confined Compression , Soil Investigation 11 - Complition And Analysis Of Laboratory And Field Test Results And Submission Of Reports In 04 Sets Alongwith Recommendations For Seletions Of Type Of Foundation With Supporting Design Details And Recommendation Of Sbc Etc Complete , Consultancy 1 - Consultancy Services For Preparation And Supply Of Architectural Drawing Plan Section And Elevation Structural Design Preapration Of Boq And Estimate Rate Analysis For Provn Of Consultancy Work For Extension Of Rcc Varandha Alongwith Rcc Roof For Airmen Billet At Lambaline Af Stn Sri Vijaya Puram Consisting Of Following Scope Of Works , Consultancy 2 - Preparation And Submission Of Self Sufficient Structural Design And Drawing Including Structural Details Structural Notes Conforming To Is 456 And Is 816 And Is 875 And Is 1893 And Is 2062 And Is 4326 And Is 13920 And Is 2911 And Any Other Latest And Relevant Is Code , Consultancy 3 - Third Party Vetting & Proof Checking The Consultant Shall Be Responsible For Third Party Vetting Or Proof Checking From Iits Or Nits Or Any Government Engineeering College Duly Signed By Authorised Signatory On Behalf Of The Institute And Not From A Professor Or Individual Of The Institute In His Personal Capacity. The Design Drawings Shall Also Be Liable For Ensuring That The Design And Drawings Are In Compliance As Per Laid Down Standards Regulations Adherence To Is Specifications And Sound Engineering Practices The Consultant Is Responsible For Obtaining Clarification From The Vetting Agency Till The Completion Of Work A Certificate That All Details Have Been Thoroughly Checked And Are In Compliance To Standards Codes Regulations In Respect Of Safety Soundness And Economy Shall Be Obtained From Vetting Agency Total Quantity : 43
Contract Date: Ref. Documents Contract Value : 3.45 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Andaman And Nicobar Islands View Result →
14.
Educational and Research Institute #11203813 Technical Bid
Tender For Selection Of System Integrator For Supply, Establishment, Operation And Maintenance Of Center Of Excellence On Digitalization Through Simulation At Government College Of Engineering, ,Amravati - Hardware Part , Battery Charge And Discharge Test System , Data Acquisition And Logging System , Thermocouple Rtd For Temperature Measurement , Battery Tester For Internal Resistance Testing , Electric Vehicle Bldc Motor Training System , Bldc Brushless Inner Rotor Brushless Dc Motor Coupled , Battery Characteristics Training System , Pmdc Motor Training System , Power And Transmission System Study Models For Ev Application , Pmsm Motor Coupled With Dc Generator Test Bench Setup , Switched Reluctance Motor Coupled , Pwm Charge Controller Training System , Sectioned Electric Vehicle Twowheeler Chassis , Sectioned Electric Vehicle Fourwheeler Chassis , Battery Resistance Spot Welding Machine , Dc Ac Clamp Meter , Noncontact Type Tacho Meter , Computing Workstations For Ev Design And Simulation , Multibody Dynamics Analysis Research Software Bundle For Ev 10 User , Power Train Gearbox Design Research Software Package , 1D3d Thermal Modelling Bms Modelling Electric Motor Ic Engine , Multiphysics Cae Research Software Package , Nmc Cell Size 18650 , Nmc Cell Size 26650 , Lfp Cell , Smart Bms Training System , Electric Vehicle Scanner , Diy Kits For 20 Students , Advanced Driver Assisting System Adas Training System For Emobility , Ac Ev Charger 10Kw , Dc Fast Charger 20Kw , Multifunction Installation Tester , Electric Vehicle Service Equipment Test Adapter Kit , Battery Tester With Inbuilt Printer , Digital Infrared Thermometer , Digital Multifunction Meter With Vfd Efdetection 3Phase Rotation , Vde Approved Insulated Tool Set For Ev , Electric Vehicle Safety Equipment , Ev Battery Assembly Testing Centre Setup , Ev Battery Pack Cell Equalizer , Regenerative Charging And Braking Training System , Ev Assembly Disassembly Kit , Three Phase Power Clampon Meter With Harmonics Measurement , Digital Insulation Multi Function Meter , Phase Sequence Indicator , Battery Quality Anaylyzer With Data Logger , Hybrid Display Module , Hybrid Trainer Module Motorized , Professional Wall Charts Approx 4 Ft 3 Ft , Professional Lab Layout And Design , Engineering Simulation Software Multiphysics Cae Research Software Includes Preprocessor And Post Processor 10 Users , 3D Cad Package 60 User , Professional Wall Charts , Professional Lab Layout And Design , Video Conferencing Setup , Electromagnetic Em Simulation , Integrated Circuit Ic Design Verification Academic Research Software , Soc Development Board With Software , Emcemi Test Equipment , Spectro Radiometer For Measurement Of The Luminous Flux Spectrum Color , 3D Printer For Prototyping , Professional Wall Charts Approx , Professional Lab Layout And Design , Revolving Chair With Arm Centre Pivot Mechanism , Computer Table , White Board With Stand , Revolving Office Chair With Arm Centre Pivot Mechanism For Faculty , Laboratory Wooden Table , Office Table For Faculty , Major Almirah With Glass Type Doors , Seminar Chairs With Desklet , Executive Office Table , Executive Office Chair , Sofa Set 321 Seater , Teapoycoffee Table , Visitors Chairs With Cushion , Major Almirah , Multi Function All In One Printer For Office And Lab , Necessary Electrification And Networking , Matting Area With Labour Work In Sq Ft , False Ceiling In Sq Ft , Window Sliding Door In Sq Ft , Window Curtains With Fitting In Sq Ft , Gypsum Plaster With Wall Putty In Sq Ft , Wall Coloring In Sq Ft , Air Conditioner 2 Ton , Cctv Camera , Interactive Board , Partitions Cubicles In Sq Ft , Training Support Part , Centre Incharge (Annual Cost) , Lab Operator (Annual Cost) Ev Lab , Faculty Training Ev Lab , Lab Operator (Annual Cost) Simulation Lab , Faculty Training Simulation Lab , Lab Operator (Annual Cost) Esdm Lab , Faculty Training Esdm Lab
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
15.
Defence #11191783 Price Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Any Guage, Thickness, Including Nainital Pattern Or Similar Pattern Roof Covering Complete All As Specified And Directed. , Demolition Of Brick Work Or Stone Masonry Precast Plain Cement Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. , Dismantling Timber Scantlings 40 Sq. Cm And Over In Section, In Any Position Complete All As Specified , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Dismantling Water Tanks 500 Ltrs Capacity Complete All As Specified And Directed. , Dismantling Water Tanks Of Any Description, Capacity Exceeding 500 Litres But Not Exceeding1000 Liters Complete. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Not Exc 1.5 Sqm Each.& Removing To Or From Store All As Specifed & Directed. , Taking Down Chowkats Or Frames Exc 1.5 Sqm But Not Exc 4 Sqm Each With Shutters (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. , Dismantling Of Ceiling Board (Flbre Pulp, Insulation Etc) Or Insulation Boards/Slabs/Blankets Any Thickness, Including Cover Fillets Complete All As Specified And Directed. , S&F In Repairs Of Galvanised Mild Steel Wire Cloth 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.18Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 4 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa (Az 150) As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F 0.63Mm Thick Galvanised Corrugated Ms Sheeting (Cgi Sheet Roofing) With Two Corrugation Side Laps, With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusive Fixed With Coach Screws And Washers As In Roofs Etc All As Specified , S&F 0.63Mm Thick Plain Galvanised Ms Sheeting Using Grade-O Sheets With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusives, As In Roof, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Complete All As Specified And Directed. , S&F Of Powder Coated Grid Frame Work For False Celling Comprising Of The Following Sections For Making Partitions Of 600X600 Mm Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including 4Mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mmx24mmx0.3Mm Thick , Cross Tee Shall Be 28Mmx24mmx0.3Mm Thick And Wall Angle Shall Be 24Mmx24mmx0.3 Mm Thick Incl 4 Mm Thick E-Board Classic (Make-Everest) For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface Complete All As Specified And Directed.Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6 All As Specified And Directed. , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls By Adding 17-19% Of Potable Water By Weight Of Material For Thickness Above 15Mm It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days 10-12 Mpa/Bulk Density 1500-1600 Kg/M3. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 20 Mtr Ht All As Specified And Directed.Make Fosroc/ Sika/ Ultrarech/ Choksey , M&L For Preparation Of New Plastered Surfaces & Applying A Layer Of Birla Putty On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Distemper Complete All As Specified And Directed. , M/L For Complete Removal Of Existing Treatment For Preparing Old Painted Surfacess And Applying Two Coat Of Distemper Oil Emulsion Over A Coat Of Primer Complete All As Specified And Directed. , M&L Three Coats Of White Wash On Ceiling Including All Preparation Complete All As Sopecified , Material & Labour For Applying Two Or More Coats Of 100% Remium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance,Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives@ 1.43 Litre/ 10 Sqm Over And Including Primingcoat Of Exterior Primer Applied @ 0.90 Litre/ 10Sqm Over New Surfaces Complete All As Specified And Directed. , M&L Preparation Of Old Surfaces Including Cornices Etc And One Coat Of Oil Bound Distemper Complete All As Specified And Directed. , S&F 20Mm Thick 2Nd Class Soft Wood (Chir) Boarding Planned One Side Fixed With Butt Joints With Nails In Any Situation/Position Except Flooring And Skirting Complete All As Specified And Directed. , M&L For 2Nd Class Hard Wood Clean Sawn In As In Scantling Framed And Over 40Sqcm Fixed With Screws Etc All As Specified And Directed.. , S&F In Repair 110Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , S&F In Repair 75Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , M&L 300X450x7mm Thick Glazed Ceramic Digital Tiles Coloured Incl , Design And Pattern As Approved Fixed As In Vertical Surface Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Cement With Colour Pigment To Match Incl Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Complete All As Specified And Directed. , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.11 Sqm But N.Exc. 0.18 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigment Incl 15Mm Thick Screed Bed In Cm 1:6 Complete All As Spd , M&L For 15Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , M&L For 20 Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Bib Tap Long Body Cp, Screwed For Iron Pipes Complete All As Specified And Directed , S&F Angle Cock 15 Mm Bore Brass Chromium Plated, Screwed Both Ends For Pipes Or For Unions Fixed In Repairs Including Making Good To Match With Existing Surface , S&F Pillar Taps 15 Mm Bore, Brass Chromium Plated , Screwed Down High Pressure With Or Without Letter Hot Or Cold With Long Screwed Shanks And Fly Nut Complete All As Specified, Fixed In Repairs. , S&F Bib Tap Standard Of Ptmt (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath Fitting), Any Colour, Screwed Foriron Pipe 15 Mm Bore Pipe (Minimum Weight 90 Gm) All As Specified, Fixed In Repairs (Make : Prayag Or Equivelent As Approved) , S&F In Repair Polymer White (Polypropeylene Delrin And Abs) Low Level Flushing Cistern 10 Ltrs Capacity, Valveless, Syphonic Action Type Complete With Inlet, Ball Valve Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete, Complete All As Specified And Directed. , S&F In Repairs, 550X400mm Vitreous China, Wash Hand Basin , Flat Back With Pedestal Excluding Trap And Waste Chain And Plug And Porcelain Stopper Including Sutaible Size Brackets Waste Pipe And Waste Coupling Complete All As Specified And Directed. , S&F Vitreous China Squatting Pan Orrissa Pattern Size 580 X 440 Mm White With Intregal Foot Rests, With & Including P Or S Trap (Excluding Material & Labour Of Flushing Cistern And Flush Pipe) Including Conection To Trap And To Flush Pipe Etc Complete Including Making Good To Floor Complete All As Specified And Directed Fixed In Repairs. , S& F In Repair Vitreous China Premium/ 1St Quality Wash Down Water Closet Ewc White/ Ivory/Off White (Closed Pattern Incl All Necessary Accessories Like Rag Bolts/ Gel Gasket Etc. (Excluding Flushing Cistern & Flush Pipe) Complete In All Respect All As Specified. , M&L Pvc (Swr) Floor Trap 75Mm Dia Plain With Grating Including Jointing With Solvent Cement Etc Complete, Fixed In Repair. , S&F Pvc Circular Top Cover Suitable To Rotational Moulded Polyethylene Water Storage Tanks Of 300 /500 Litres Capacity Tanks Of Standard Mares, With 6 Mm Dia Nut And Bolts On Two Ends Of Cover To Act As Hinge As Will As Locking Arrangement For Side Opening , M&L For Sunken Floor Treatment As Described As Under (I) To (Vii) :- (I) Demolition Of Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Or In Any Type Of Filling In Sunken Portion & Cleaned The Sunken Portion Incl Vertical Wall Surface Complete As Directed. (Ii) M&L To Fill The Sunken Floor With Plain Cement Concrete ( 1:5:10) Type E-2 Using Bk Aggregate Over The Treated Surface Complete All As Specified And Directed. (Iii) M& L 40Mm Thick (Min) Plain Cement Concrete (1:2:4) Type B-0 Using 12.5 Mm Graded Stone Aggregate With Integral Water Proofing Compound As Per Manufacturer Instructions On Bottom Of Sunken Portion With Proper Slope Towards Spout. Vertical Sides Shall Be Plastered In Cm (1:3) 15 Mm Thick Mixed With Water Proofing Compound As Per Manufacturer Instructions. Plaster Shall Be Extended Over Plain Cement Concrete Coving When The Same Is Green I.E. Plain Cement Concrete & Plaster Be Carried Out At The Same Time Complete All As Specified And Directed.(Iv) After Laying Sewage/ Plumbing Pipes With Fixtures In Position 2 Coats Of Omiplas Ep-101 Epoxy Compound Shall Be Applied Complete All As Specified And Directed.(V) Spouts Of 25Mm Dia Gi Pipe Light Grade Projecting 450Mm Clear Of Face Outer A Wall With Mosquito Proof Cap On Inner Face Of Pipe Shall Be Provided To Drain Out Seepage Water ,Including Cutting Holes And Making Good If Needed As Specified And Directed. (Vi) Test Again Of Water Tightness By Pounding For 72 Hours & Rectify Defects If Any Till Total Elimination Of Defects Complete All As Specified And Directed.The Sunken Portion Shall Be Tested For Leakage / Seepage / Dampness By Pounding With Water For 72 Hours. In Case Any Defect Is Noticed The Portion Shall Be Grouted With Cement Slurry Mixed With Suitable Chemical & Tested Again. The Process Of Grouting And Testing Shall Be Repeated Till Leakage / Seepage / Dampness Is Eliminated. , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/ Window/ Ceosetory Window & Other Frames/ Chowkhat Of Size 45 X 70 Mm Comprising Of Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wwod Powder/ Rick Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Stat Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modules Of Elasticity 900 N / Mm 2 And Resistance To Spread Of Flame Of Class A Catogory With Property Of Being Termite/ Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With Ms Hold Fast/Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge (M.S. Hold Fast/ Lugs Or Ss Dash Fasteners Shall Be Paid For Separately). , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Plain Flush Door Shutter Of 35 Mm Thick Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/ Cum And Screw Withdrwal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N Mm2 Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Catogary With Property Of Being Termite/ Borer Proof, Water/ Moisture Proof And Fire Retardanat And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws, All As Per Direction Of Engineer-In-Charge (Note:- Stainless Steel Butt Hinges And Necessary Ss Screws Shall Be Paid Separately. , S&F Mild Steel Work As Hold Fasts, Bands, Straps, Supports Or Stays For Pipes Eaves Gutter Including Bolts If Required, Hooks (Stay), Clamps And Similar Small Articles, Conforming Tofe 310-0 Or Fe 410-0 Complete All As Specified And Directed. , S&F 100Mm Size Ms Butt Hinges, Medium Weight, Cold Rolled And Fixed Complete All As Specified And Directed. , S&F 150Mm Long Aluminium Tower Bolt And Fixed Complete All As Specified And Directed. , S&F 125 Mm Size Aluminium Handle Plate Type Anodised Complete All As Specified And Directed. , M & L For Roof Surface Must Be Pressure-Washed With Water With, Is To Be Used To And/ Or Remove All Dirt, Dust, Chalking And Waste Products. Remove Algae, Mold By Using Bleach Solution. 2 Tiles Joint Repair All Visible And Joint More Than 0.50Mm And Not Giving Hollow Sound, On The Tiles Roof Or At The Junctions Of Flat Roof & Vertical Parapet Wall, Pipe Joints, Should Be Cut And Widen V Shape With Mechanical Cutter In The Size (6Mm W X 6Mm D) And Fill With Pmm Methodology.Glass Fiber Apply Urp Or Primeseal A On The Well Prepared Groove, Allow To Cure Tack Free. Followed By Filling All The Joints Covering The Entire Area Uniformly With Suitable Chemical. Allow Chemical To Cure A Minimum 24 Hours. Apply Minimum 50Mm-100Mm Width 45 Gms Glass Fibre Mesh/ Non-Woven Geo Testile Fleece With The Coat Of Roofseal Classic Along The Length Of Crack When The 1St Coat Is Still In Wet Condition. Apply The Second Coat With An Interval If 4-6 Hours. Waterproofing: Apply A Coat Of Roofseal Classic (Diluted With Water In The Ratio 2:1) As Self Priming 14.0-18.0 Sq. Mt/Litre.Allow Coating To Dry For 3-4 Hours. Applt Two Coats Of Dr Fixit Roofseal Classic/Litre/Coat, Without, The Rate Of Application Being The Same For Both The Coats. This Would Ensure Correct Consumption Of Material That Will Deliver A Total Of Dft Of Microns. Allow The System To Air Cure For 5 Days Minimum. Check To See No Void Surface Is Left Untreated/Uncoated. The Material Having Following Technical Specification As Per Astm D 6083 M- Type Ii, Attains A Tensile Strength Of 2.5 N/Mm2 Confirming To Astm D 2370: Elongation At Break 300% Confirming Astm D 2370, Adhesion To Concrete 2.0N/Mm2 Confirming Astm D 4541 And Crack Bridging Ability Up To 2Mm, Air Cure The Coating For 7 Days Before Water Pound Test For 48 Hrs. The System Comes With 7 Year Waterproofing Warranty From Service Provider. For Vertical Surface : Apply 2 Coat Of Dr Fixit Roofseal Classic With Forced Coverage Of /Litre/Coat. Entire Terrace Should Be Coated With Roofseal Classic Alongwith Parapet Walls Needs To Be Enveloped With Roofseal Classic/Raincoat System. The Total 3 Coats Treatment Inclu Taking Down/Dismantling Of Old Tarfelt/Old Unserviceable Roof Treatment From Reinforced Cement Concrete Roof By Scrapping, Broomig And Washing With Water Etc Including 10Mm Thick Rendering In Cm 1:3 With Water Proofing Compound Complete All As . Make : Dr Fixit, Asian Or Equivalent (Note : The Treatment Should Be Carried Out Through Authorised Applicator Only) , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
16.
Housing Urban and Rular Development #11144599 Technical Bid
Tender For Tourism Development And Beautification Of Paataleshwar Mandir At Gram Sabha Kalpi Dist- Jalaun- 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. Dsr 2.6.1 Dsr 2.6.1 2 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) Dsr 4.1.8 3 Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: Dsr 2.35.3.1 4 Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. Dsr 2.25(A) 5 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. Dsr 2.27 6 Boring With Hydraulic Piling Rigs With Power Units, Providing And Installing Cast In Situ Single Under Reamed Piles Of Specified Diameter And Length Below Pile Cap In M-25 Cement Concrete, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And The Length Of The Pile To Be Embedded In Pile Cap Etc. All Complete. (Length Of Pile For Payment Shall Be Measured Upto To The Bottom Of Pile Cap) : 300 Mm Dia Piles Dsr 20.3.1 7 Vertical Load Testing Of Piles In Accordance With Is 2911 (Part Iv) Including Installation Of Loading Platform By Kentledge Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge. 1.Initial Test Dsr 20.6.1 8 Vertical Load Testing Of Piles In Accordance With Is 2911 (Part Iv) Including Installation Of Loading Platform By Kentledge Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge. 2.Routine Test Dsr 20.6.1.2 9 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 5.1.2 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) Dsr 5.1.2 10 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. Dsr 5.9.1 11 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 5.2.2 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size) Dsr 5.2.2 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. Dsr 5.9.6 13 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). Dsr 5.3 14 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Dsr 5.9.5 15 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform Dsr 5.9.3 16 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. Dsr 5.22.6 17 Brick Work With Bricks Of Class Designation 15 (Class-150) In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand (Fm 1.50 To 2.00)) Dsr Ar 18 Brick Work With Bricks Of Class Designation 15 (Class-150) In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand (Fm 1.50 To 2.00)) Dsr Ar 19 Half Brick Masonry With Bricks Of Class Designation 15 (Class-150) In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement : 4 Coarse Sand (Fm 1.50 To 2.00)) Dsr Ar 20 12 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 1:6(1 Cement: 6 Coarse Sand) Dsr 13.4.2 21 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix: 1:6(1 Cement: 6 Coarse Sand) Dsr 13.5.2 22 Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding Tor.C.C. Projections. Dsr 5.30 23 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colors, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Dsr 11.37A 24 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming Tois: 15622 (Thickness To Be Specified By The Manufacturer), Of Approvedmake, In All Colours, Shades Except Burgundy, Bottle Green, Black Ofany Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Stepsand Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm,Including Pointing In White Cement Mixed With Pigment Of Matching Shadecomplete. Dsr 8.31 25 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Bespecified By The Manufacturer) With Water Absorption Less Than 0.08%And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades,Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand),Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting Thejoints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm Dsr 11.41A.3.1 26 Providing And Laying Polished Granite Stone Flooring In Required Designand Patterns, In Linear As Well As Curvilinear Portions Of The Building Allcomplete As Per The Architectural Drawings With 18 Mm Thick Stone Slabover 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With Whitecement Slurry Admixed With Pigment Of Matching Shade Includingrubbing, Curing And Polishing Etc. All Complete As Specified And Asdirected By The Engineer-In-Charge. Polished Granite Stone Slab Of Colour Black, Cherry/Rubyred Or Equivalent Dsr 11.56.1 27 Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Inline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Wire Mesh / Glazing Of Plain/ Toughened/ Laminated/ Double Glass Unit With / Without High Performance Coatings As Per Design Requirements And Conforming To Is: 3548 & Is: 16231 Shall Be Paid Separately. Note:- Structural Design Proof Checked From A Government Engineering Institute, To Be Provided By The Manufacturer For : (I) Sites With Basic Wind Speed > 45 M/Sec As Per Is 875 – Part 3 (Ii) Sites With Structure Height More Than 20M For All Wind Speeds. Three Track Three Panels Sliding Window With Two Glazed & One Wire Mesh Panels With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. Using R3 Series With Frame (98Mm & Above) X (40Mm & Above) & Both Glazed And Fly Screen Sash (30Mm & Above) X (55Mm & Above) With Zinc Alloy (Zamak) Powder Coated Handle On Every Glazed Panel Along With Multi-Point Locking System. (Height Upto 1.2M). Dsr 9.147.A4.1 28 Three Track Three Panels Sliding Door With Two Glazed & One Wire Mesh Panels With Aluminium Channel For Roller Track, Wool Pile, Zinc Alloy (Zamak) Powder Coated Handle On Two Panels Along With Multi-Point Locking System, Adjustable Nylon Rollers With Ss 304 Body. Using R3 Series With Frame (98 Mm & Above) X (40 Mm & Above) & Both Glazed And Fly Screen Sash (30 Mm & Above) X (74 Mm & Above). (Height Upto 2.5 Metre). Dsr 9.147.B3.1 29 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) Dsr 21.3.2 30 Filling The Gap In Between Aluminium/ Stone/ Wood Frame And Adjacent Rcc/Brick/ Stone/ Wood/ Ceramic/ Gypsum Work By Providing Weather/Structural Non Sag Elastomeric Pu Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete, Complying To Astm C920, Din 18540- F & Iso 11600. Upto 5Mm Depth And 5 Mm Width Dsr 21.19.1 31 Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With 12 Mm Mild Steel U Beading Dsr 9.51.2 32 Distempering With Oil Bound Washable Distemper Of Approved Brandand Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Dsr 13.41.1 33 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqmover And Including Priming Coat Of Exterior Primer Applied@ 2.20 Kg/10 Sqm) Dsr 13.46.1 34 Providing And Applying White Cement Based Putty Of Average Thickness1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wallsurface To Prepare The Surface Even And Smooth Complete. Dsr 13.80 35 Providing And Laying Integral Cement Based Water Proofing Treatmentincluding Preparation Of Surface As Required For Treatment Of Roofs,Balconies, Terraces Etc Consisting Of Following Operations: Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Ofcement Admixed With Water Proofing Compound Conformingto Is. 2645 And Approved By Engineer-In-Charge Over The Rccslab Including Adjoining Walls Upto 300 Mm Height Includingcleaning The Surface Before Treatment.(B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm. With Average Thickness Of 120Mm & Minium Thickness At Khurra As 65 Mm Dsr 22.7.1 36 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1 M X1 M X 400Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarsesand) And A Coat Of Neat Cement, Rounding The Edges And Makingand Finishing The Outlet Complete.M Dsr 12.22 37 Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10 Mm And Down Gauge), Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : In 75X75 Mm Deep Chase. Dar 12.21.1 38 Supplying, Fabricating, Transporting, Hoistingand Fixing In Position Good Quality Of 70 Mm Redsandstone In Various Elements For All Levels.Stone Shall Be Free From Cracks, Lines Stains Andeven In Shade For Each Element. The Stone Shall|Be Fine Grained And Reddish Or Buff-Colored(Locally Available). The Work Shall Be Carried Outas Per Attached Drawings With Different Process|Of I.E Carving (Manual/ By Machine), Ornamentalwork, Traditional Work, Figure Work (Any Type,Any Size), Cnc Cutting, Moulding. The Carvingand Molding Work Shall Be Of Very Good Quality.|The Stones To Be Fixed In Line, Level And Plumb Inall Respect With The Use Of Brass Clamps, Pins, (To|Be Paid Separetely) Dowels, Cement Slurry With|Matching Pigment And Epoxy Of Akemigermany, Ardex Endura, Myk Laticrete Orjapproved Make As Required And As Approved Bythe Architects. Dsr Ar 39 Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required. White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests Dsr 17.1.1 40 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : 17.2.1 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid Dsr 17.2.1 41 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require White Vitreous China Flat Back Wash Basin Size 550X 400 Mm With Single 15 Mm C.P. Brass Pillar Tap Dsr 17.7.4 42 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete 32 Mm Dia C Dsr-17.28.1.1 43 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138 Mm, Breadth 102 Mm, Height Of 75 Mm With Concealed Fitting Arrangements. Weighing Not Less Than 106 Gms. Dsr 18.65 44 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. Dsr 17.31 45 Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In -Charge. Dsr 17.16A 46 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. External Work. 100 Mm Nominal Inner Dia Pipes Dsr 18.9.9 47 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. External Work. 80 Mm Nominal Inner Dia Pipes Dsr 18.9.8 48 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron/Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10X10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Cost Of Cutting Holes And Making Good The Walls Etc. For . 100 Mm Dia Pipes Dsr 17.37.1 49 Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron/Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10X10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Cost Of Cutting Holes And Making Good The Walls Etc. For . 75 Mm Dia Pipes Dsr 17.37.2 50 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes. 110 Mm Dia Pipes Dsr 12.41.2 51 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. Dsr 12.22 52 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised Pvc Rain Water Pipes By Means Of 50X50X50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. 110 Mm Dsr 12.43.2 53 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall 25 Mm Nominal Outer Dia Pipes Dsr 18.7.3 54 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall 32 Mm Nominal Outer Dia Pipes Dsr 18.7.4 55 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall 40 Mm Nominal Outer Dia Pipes Dsr 18.7.5 56 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 18.8.1 15 Mm Nominal Outer Dia Pipes Dsr 18.8.1 57 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 20 Mm Nominal Outer Dia Pipes Dsr 18.8.2 58 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions 15 Mm Nominal Bore Dsr 18.21.2.1 59 Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 : 18.49.1 15 Mm Nominal Bore Dsr 18.49.1 60 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 15 Mm Nominal Bore Dsr 18.50.1 61 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 18.53.1 15Mm Nominal Bore Dsr 18.53.1 62 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) : 25 Mm Nominal Bore Dsr 18.17.1 63 Providing And Fixing Brass Stop Cock Of Approved Quality : 15 Mm Nominal Bore Dsr 18.16.1 64 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Of Approved Brand And Manufacture With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. Dsr 18.48 65 Excavating Trenches By Mechinical / Manual Means Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, For All Depth, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : All Kinds Of Soil,Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia Dsr 2.10.1.2 66 Providing, Laying And Jointing Glazed Stoneware Pipes Class Sp-1 With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 (1 Cement : 1 Fine Sand) Including Testing Of Joints Etc. Complete : 19.1.1 100 Mm Diameter Dsr 19.1.1 67 Providing, Laying And Jointing Glazed Stoneware Pipes Class Sp-1 With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 (1 Cement : 1 Fine Sand) Including Testing Of Joints Etc. Complete 150 Mm Diameter Dsr 19.1.2 68 Providing And Laying Cement Concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design : 19.2.1 100 Mm Diameter S.W. Pipe Dsr 19.2.1 69 Providing And Laying Cement Concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design :150 Mm Diameter S.W. Pipe Dsr 19.2.2 70 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 Dsr 19.4.2.1 71 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top Slab With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 Dsr 19.7.1.1 72 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Mdular Type Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group A Dsr 1.10.3 73 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. Dsr 1.12 74 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire. Dsr 1.14.1 75 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1X 2.5 Sq. Mm Earth Wire. Dsr 1.14.2 76 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire. Dsr 1.14.4 77 Supplying And Fixing Metal Box Of 150 Mm X 75 Mm X 60 Mm Deep (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 3 Pin 5/6 A Socket Outlet And 5/6 A Piano Type Switch, Connections, Painting Etc. As Required. Dsr 1.29 78 Supplying And Fixing 20 Amps, 240 Volts, Spn, Industrial Type Socket Outlet, With 2 Poles And Earth Metal Enclosed Plug Top Along With 20 Amps. \C\ Curve, Sp Mcb In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet, And Complete With Connections, Testing And Commissioning Etc. As Required. Dsr 2.18 79 Supply And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Dsr 1.25 80 Supply And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. Dsr 1.26 81 Supply And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required : 20 Mm. Dsr 1.21.1 82 Supply And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required : 25 Mm. Dsr 1.21.2 83 Supply And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required : 32 Mm. Dsr 1.21.3 84 Supplying And Fixing 5 Amps. To 32 Amps. Rating, 240 Volts `C Series, Miniature Circuit Breaker (Mcb)Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole Dsr 2.10.1 85 Supplying & Fixing Single Pole, Blanking Plate In The Existing Mcb Db Complete Etc. As Required. Dsr 2.11 86 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. 40 Amps Dsr 2.12.1 87 Supplying And Fixing Following Way, Sp&N, Sheet Steel, Mcb Distribution Board, 240 V On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb / Rccb / Isolator). 6 Way, Double Door Dsr 2.3.1 88 Supplying And Fixing Following Way, Horizontal Type Tp&N, Sheet Steel Mcb Distribution Board, 415 V On Surface /Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required (But Without Mcb / Rccb / Isolators). 4 Way (4 + 12), Double Door Dsr 2.4.1 89 Earthing With Gi Earth Plate 600Mm X 600 Mm X 6Mm Thick Including Accessories And Providing Masonary Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc, With Charcoal/ Coke And Salt As Required. Dsr 5.4 90 Supplying And Laying 25 Mm X 5 Mm. G.I. Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) Dsr 5.9 91 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. Dsr 5.11 92 Providing And Fixing 25Mm X 5 Mm G.I Strip On Surface Or In Recess For Connections Etc. As Required. Dsr 5.15 93 Providing And Fixing M.V. Danger Notice Plate Of 200Mmx150Mm Made Of Mild Steel, Atleast 2Mm Thick And Vitreous Enamelled White On Both Sides And With Inscription Single Red Colour On Frlsont Side As Required. Dsr 2.21 94 Providing And Fixing Circular/ Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron/ M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing. Dsr Civil 10.18 95 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required. 5/6 A Switch Dsr 1.24.1 96 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet Dsr 1.24.4 97 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 1 Or 2 Module (75Mmx75Mm) Dsr 1.27.1 98 Installation, Testing And Commissioning Of Pre-Wired, Flourescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tubes Etc. Directly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm. Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. Dsr 1.41 99 Installation, Testing And Commissioning Of Ceiling Fan Including Wiring The Down Rod Of Standard Length (Upto 30 Cm.) With 1.5 Sq. Mm. Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. Dsr 1.45 100 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. Dsr 19.1 101 Supply Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 2X22 Watt Suitable For Upto 2X22 Watt Led Polycarbonate Tube Light Complete Including Tube Suitable For Both Surface & Suspended Complete In All Respect. Mr 102 Supply Of Recess/Surface Mounting Round 10 W To 15 W Led Cut Out Min 125 Mm, Height Min. 40Mm, Led Down Lighiter Having Powder Coated Die Cast Aluminium Housing With Heat Shink,Diffuser/Reflector And Driver Set. Suitable For 24Hr Continuous Operation, Complete In All Respect. Mr 103 Supply And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. 16 Sq. Mm 4 Core Mr 104 Supply And Laying Of Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. 35 Sq. Mm 3-1/2 Core Mr 105 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 16 Sq. Mm 4 Core Dsr 9.1.33 106 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 3½ X 35 Sq. Mm (35Mm) Dsr 9.1.21 107 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class-150 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dsr 6.1.1 108 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Slab Dsr 5.9.20 109 Cement Plaster 1:3 (1 Cement: 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement. 20Mm Thick Dsr 13.9.2 110 Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate Dsr 11.3.1 111 Providing M.S. Foot Rests Including Fixing In Tank With 20X20X10 Cm Cement Concrete Blocks 1:3:6 (1 Cement:3 Coarse Sand :6Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design With 20X20 Mm Square Bar Dsr 19.15.1 112 500 Mm Diameter C.I. Cover (Medium Duty) The Cover To Be Not Less Than 58 Kg Dsr 19.18.2 113 C.I. Plain Bend (Dsr 17.39.1.2) Dsr 17.39.1.2 114 Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 (Dsr 19.32.1) Dsr 19.32.1 115 Providing And Fixing Precast Rcc Garden Benches With Hand Rest, Each Bench Consists Of 2Nos. L-Shape Base Support In Grey Cement Colour Of Size 80Mm X 450Mm X 890 Mm And Base Width 690Mm, 1 No. Rcc Plank In Red Colour Of Size 1500Mm X 400Mm X 50Mm, And 1 No. Rcc Plank In Red Colour Of Size 1500Mm X 425Mm X 50Mm. Seating Length Of The Bench Is 1500Mm, Seating Height Of The Bench Is 450Mm And Total Height Of The Bench Is 1000Mm As Per Drawing Attached, Finishing Etc Complete And As Per The Direction Of Engineer-In-Charge. Mr 116 Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Pvc Medium Well Casing (Cm) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire And Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer -In-Charge. (I) 110 Mm Nominal Size Dia (Dsr 23.3.1) 117 Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well Unplasticized Pvc Medium Well Screen (Rms) Pipes With Ribs, Conforming To Is: 12818, Including Hire & Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer-In-Charge. (I) 110 Mm Nominal Size Dia. (Dsr 23.4.1) 118 Supplying, Filling, Spreading & Leveling Coarse Sand Of Size Range 1.5 Mm To 2 Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer -Incharge. (Dsr 23.7) 119 Providing And Fixing Suitable Size Threaded Mild Steel Cap Or Spot Welded Plate To The Top Of Bore Well Housing/ Casing Pipe, Removable As Per Requirement, All Complete For Borewell Of: 100 Mm Dia (Dsr 23.13.1) 120 Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. 32 Mm Dia Nominal Bore (Dsr 18.12.4) 121 Providing And Fixing M.S. Clamp Of Required Dia To The Top Of Casing/ Housing Pipe Of Tubewell As Per Is: 2800 (Part I), Including Necessary Bolts & Nuts Of Required Size Complete. 100 Mm Clamp (Dsr 23.14.1) 122 Providing And Fixing Bail Plug/ Bottom Plug Of Required Dia To The Bottom Of Pipe Assembly Of Tubewell As Per Is:2800 (Part I). 100 Mm Clamp (Dsr 23.15.1) 123 S/F 1.5 H.P. Submersible Pump With Control Pannel, Cable, Columnpipe And All Accessories Complete. Mr 124 S/F Of Finolex Of Copper Cable Isi Marked Submersible Cable Size 4Sqm 4Core. Mr 125 Excavation Work By Mechanical Means (Hydraulic Excavator)/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. Dsr 2.9.1 126 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) : Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick Dsr 8.14.1.5 127 Providing And Fixing Stainless Steel Cramps Of Required Size And Shape For Anchoring Stone Wall Lining To The Backing Or Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases In Stone And Holes In Walls Wherever Required. Dsr 8.15 128 Providing And Fixing Copper Pins 7.5 Cm Long 6 Mm Diameter For Securing Adjacent Stones In Stone Wall Lining In Cement Mortar 1:2 (1 Cement : 2 Coarse Sand), Including Making The Necessary Chases. Dsr 8.16 129 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished,Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanitycounters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cementmortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement,Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing,Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm (Granite Of Any Shade) Dsr 8.2.2.2 130 Cost Of Stone Writing. Mr 131 S/F Of Decorative 8To 16 Watt Led Bollard Luminaire With Driver Set Confirming To Ip 65 Protection Complete In All Respect. Mr 132 S/F Of Factory Wired Led Flood Light Luminaries With Die Cast Aluminium Housing Built With Driver Set Suitable For 40To50Watt Confirming T Ip 65/66 Protection Complete In All Respect. Mr 133 Preparation And Consolidation Of Sub Grade With Power Road Roller Of 8 To 12 Tonne Capacity After Excavating Earth To An Average Of 22.5 Cm Depth, Dressing To Camber And Consolidating With Road Roller Including Making Good The Undulations Etc. And Re-Rolling The Sub Grade And Disposal Of Surplus Earthwith Lead Upto 50 Metres. Dsr 16.1 134 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern. Dsr 16.91.2 135 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineerin- Charge (Length Of Finished Kerb Edging Shall Be Measured To Calculate Volume For Payment). (Precast C.C. Kerb Stone Shall Be Approved By Engineer-In-Charge). Dsr 16.69 136 Trenching In Ordinary Soil Up To A Depth Of 60 Cm Including Removal And Stacking Of Serviceable Materials And Then Disposing Of Surplus Soil, By Spreading And Neatly Leveling Within A Lead Of 50 M And Making Up The Trenched Area To Proper Levels By Filling With Earth Or Earth Mixed With Sludge Or/And Manure Before And After Flooding Trench With Water (Excluding Cost Of Imported Earth, Sludge Or Manure). Dsr-2020 (H &L) 137 Supplying And Stacking Of Good Earth At Site Including Royalty But Including Carriage 1Km (Earth Measusred In Stacks Will Be Reduced By 20% For Payment). Dsr-2020 (H &L) 138 Supplying And Stacking At Site Dump Manure From Approved Source, Including Carriage Up To 1 Km (Manure Measured In Stacks Will Be Reduced By 8% For Payment) : Screened Through Sieve Of I.S. Designation 16 Mm Dsr-2020 (H &L) 139 Mixing Earth And Sludge Or Manure In The Required Proportion Specified Or Directed By The Officer-In-Charge.. Dsr-2020 (H &L) 140 Spreading Of Sludge, Dump Manure And/Or Good Earth In Required Thickness As Per Direction Of Officer-In-Charge (Cost Of Sludge, Dump Manure And/ Or Good Earth To Be Paid Separately). Dsr-2020 (H &L) 141 Rough Dressing The Trenched Ground Including Breaking The Clods. Dsr-2020 (H &L) 142 Fine Dressing The Ground Dsr-2020(H &L) 143 Digging Holes In Ordinary Soil And Refilling The Same With The Excavated Earth Mixed With Manure Or Sludge In The Ratio Of 2:1 By Volume (2 Parts Of Stacked Volume Of Earth After Reduction By 20% : 1 Part Of Stacked Volume Of Manure After Reduction By 8%) Flooding With Water, Dressing Including Removal Of Rubbish And Surplus Earth, If Any, With All Leads And Lifts (Cost Of Manure, Sludge Or Extra Good Earth If Needed To Be Paid For Separately) :Holes 90 Cm Dia, And 90 Cm Deep Dsr-2020 (H &L) 144 Preparation Of Beds For Hedging And Shrubbery By Excavating 60 Cmdeep And Trenching The Excavated Base To A Further Depth Of 30 Cm, Refilling The Excavated Earth After Breaking Clods And Mixing With Sludge Or Manure In The Ratio Of 8:1 (8 Parts Of Stacked Volume Of Earth After Reduction By 20% : One Part Of Stacked Volume Of Sludge Or Manure After Reduction By 8%), Flooding With Water, Filling With Earth If Necessary, Watering And Finally Fine Dressing, Leveling Etc. Including Stacking And Disposal Of Materials Declared Unserviceable And Surplus Earth By Spreading And Leveling As Directed, Within A Lead Of 50 M, Lift Up To 1.5 M Complete (Cost Of Sludge, Manure Or Extra Earth To Be Paid For Separately). Dsr-2020 (H &L) 145 Providing And Stacking Of Hamelia (10X10X600Mm) As Per Direction Of The Officer-In-Charge. Mr 146 Providing And Stacking Of Casurina Topiary (300X300X1800Mm) As Per Direction Of The Officer-In-Charge. Mr 147 Providing And Stacking Of Plumeria Alba Bushy (300X300X2400Mm ) As Per Direction Of The Officer-In-Charge. Mr 148 Providing And Stacking Of Ground Cover Grass As Per Direction Of The Officer-In-Charge. Mr
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
17.
Defence #11104420 AOC
Tender For Repairs / Re-Novation Of Ofti And Ofti Work Shop Buildings Inside Factory Area At Ofmk.; 1 Site clearence 2 FELLING OF TREE: Felling of tree exc.30 cm and not exc.100 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50m and clearing site 3 GRUBBING UP TREE TRUNK : Grubbing up tree trunk of girth exceeding 100 mm and not exceeding 150 mm, including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable materials and removing of unserviceable materials to a distance n. exc. 50 m and clearing site. 4 Demolition of cement concrete of any description and in any position not otherwise specifically provided for.Complete all as specified directed. 5 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar. Complete all as specified directed. 6 Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Complete all as specified directed. 7 Dismantling floor,heartor wall tiling including cement mortar bedding but nor baking removing serviceable tiles to stores and rubbish off the premises.Complete all as specified directed and directed. 8 Taking down : Taking downcement or cement lime plaster, any description on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc. 9 Removing building materials etc.other than spoilupto a distance of 1.0 Km, including loading, unloading and stacking at the destination. 10 Brick work with sub class ‘B’ bricks straight or curved in plan with 1:6 cement mortar.Complete all as specified and directed. 11 Stone Masonry : Walling of Squared Rubble regular coursed Stonemasonry, well bonded, bedded and solidly hearted built in with 1:6 cement mortar, Complete in all respects as specified and directed. 12 Damp proof course to horizontal or vertical surfaces In cement concrete 1:2:4, type B-0, 40 mm thickincluding necessary formwork . 13 Flush Pointing with 1:4 cement mortar to square rubble, coursed, well bonded and solidly hearted built in cement mortar as directed. 14 Vitrified tiles : Supply and laying of Light shade vitrified tiles 10 mm thick (Square/Rectangle) polished , area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Floor tile finishglossy/mat/ antiskid will be as decided by EIC. Complete all as specified and directed . Make : Johnson, Orient bell, AGL as approved by EIC. 15 GRANITE : S&F Granite 25 mm thk (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed. 16 FLOOR TILING :Supply & fixing Coloured non skid ceramic tiles in flooring, 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell 17 SCREED BED : Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6. Complete all as specified and directed. 18 Plastering : Rendering of 10mm thick plastering with 1:6 cement mortar on fair faces of brick work or concrete surfaces. Complete in all respects as specified and directed. 19 Rounding to edges of stone slabs / granite one edge,such as in steps, cooking platform, and other similar situations. Complete all as specified and directed. 20 Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc. complete as directed by EIC. 21 Taking down wooden wall panelling of any description and similar work as directed. 22 Snap grid : Supply and fixing of 605x605 mm snap gridGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners withand including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediatechannel with connecting clips across the intermediatechannel at 457 mm centre to centre. Complete all as specifiedand directed, Make : Armstrong 23 Supply and fixing of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. 24 POP ceiling : Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mmwith 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately). Complete all as specifiedand directed, Make : Armstrong 25 Ceiling board : (M&L) S&F Exposed metal frame ceiling with calcium silicate boardof siliceous and calcareous material reinforced with cellulose fibre / PVC laminated gypsum tiles with MPL film on rear side, 8 mm thk.for fixing in 600 mm x 600mm grid,Make: Gyproc/ La gyp 26 Door shutter repair : Taking down door shutter of any description exc. 1 sqm and not exc. 2 sqmand repairing and adjusting to the required size including fixing builders hard ware and refixing to the same opening. complete all as specified and directed. 27 Dismantlingof structural steel work including doors, gates, but excluding framed truss etc. Complete all as specified directed. 28 UPVC window / Ventelator : Supply and fixing factory made UPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension . Complete all as specified and directed. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, 29 UPVC window : Three track three panels sliding window with fly proofS.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extrudedinterlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy bodywith single nylon rollers (weight bearing capacity tobe 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, including drillingof holes for fixing hardwares and drainage of wateretc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified anddirected by Engineer-in-Charge. 30 UPVC door : Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proofS.S. wire mesh (Two nos. glazed & one no. wire meshpanels) made of (big series) frame 116 x 45 mm & sash46 x 82 mm both having wall thickness of 2.3+ 0.2 mm and single glazing bead/ double glazingbead of appropriate dimension. (Area of door above2.00 sqm upto 5.00 sqm) comprising of uPVCchambered frame, with in-built roller track and sashextruded profiles duly reinforced with 1.60 + 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionuPVC extruded glazing beads, uPVC extrudedinterlock and uPVC extruded Inline sash adaptor (ifrequired), EPDM gasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side of extremepanels along with zinc plated mild steel multi pointlocking having transmission gear with keeps, zincalloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustabledouble nylon rollers (weight bearing capacity to be120 kg), G.I fastener 100 x 8 mm size for fixing frameto finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut andfusion welded at all corners, including drilling ofholes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacentfinished wall shall be filled with weather proof siliconsealent over backer rod of required size and ofapproved quality, complete all as specified anddirectd. 31 steel wire cloth : Supplying and Fixing in repairs stainless steel wire cloth0.36mm nominal dia.(Guage 28) of wire and width of aperture 1.4mm to wooden / steel doors/ windows, including fixing with and necessary screws, nut bolts,nails and removal of existing damaged cloth etc., complete all as specified and directed 32 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.0 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 33 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.8 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 34 Wooden Wall panelling : S & F of Prelaminated particle board18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work. Complete as specified and directed at site. 35 Wooden panelling frame work : S&F of battens frame work using wooden clean sawn 2nd class soft wood battens of cross sectional area exc. 15 & not exc. 25 sq.cm at a spacing of 35 centres. Complete as specified and directed at site. 36 PCC paving : PCC 1:4:8 in floors/ pavingoftype D-2, 1:4:8 with 40mm graded aggregate,100 mm thick.Complete all as specified and directed. 37 Earth work in excavation in all kind of soils by mechanical means (Hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge 38 Soling (or sub base) of spread thickness 150 mm with broken boulders or quarried stone, inter sticesfilled, surface formed and rolled and consolidated torequired gradient and camber. Complete all as specified and directed. 39 Hard core with broken stone/boulders of gauge not exc. 63mm, deposited, spread leveled in layers not exceeding 15 cm thick, and watered consolidated to required gradient & camber including watering. Complete all as specified and directed. 40 Moorum filling in floors or pavings laid in layers not exe. 15cm thick , spread leveled and rammed including watering. Complete all as specified and directed 41 Stone sett flooring (M&L) with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 42 Edge stones to flooring (M&L) with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 43 PCC paving : PCC 1:2:4 in floors/ pavingoftype B-2, with 40mm graded aggregate, 100 mm thick. Including finishing concrete surface even and smooth surface without using extra cement.Complete all as specified and directed. 44 Wearproof topping 20 mm thick using CC 1:2:4, as specified incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner). Complete all as specified and directed. 45 Supply of metalic floor hardener 46 Surface excavation not exceeding 30 cm deepand averaging 20 cm deep in hard / dense soil and getting out. Complete all as specified and directed 47 PCC FLOORING : Cement concrete of 100 mm thickness in floors, sub-floors, sub-bases, pavings etc. oftype B-1, 1:2:4 (20 mm graded aggregate) 48 Smoth finish : Finishing cement concrete surface even and smooth using extra cement. 49 CC Paver blocks : S&F of Machine pressed precastconcrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement & pigment (Coloured)Complete all as specified and directed. 50 CC chequered tiles :S&F of cement concrete chequered tiles with grey pigment cement and pigments(Coloured tiles) for pavements. size of tile 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors.Complete all as specified and directed. 51 PCC paving : PCC 1:3:6 in floors/ pavingof type C-2, with 40mm graded aggregate, 100 mm thick.Complete all as specified and directed. 52 Forming 12mm thick Expansion joints for 100 thick slabsfilled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A. ’ Complete all as specified and directed. 53 Structural steel (S&F) : Structural steel work confirming to Fe-410 W (Gde-E-250) quality-A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, including application of one coat of Zinc chromate primer paint .Make:TATA, Jindal 54 Structural steel (S&F) : Structural steel work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Steel confirming to Fe410W (Gde E-250 quality A). Make : TATA, Jindal, Complete all as specified directed. 55 Structural steel (S&F) : Mild steel bolts. purpose made. of dia. of neck n.exc. 12 mm with hexagonal orsquare head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long. Complete all as specified directed. 56 Roofing sheet : Supply and fixing of pre painted galvalume aluminium zinc coating GI basedcorrugated/ trapezoidal profile roofing sheets of thickness 0.5 mm having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws etc. Make : TATA / Jindal /Essar. Complete all as specified and directed. 57 Supply only of liquid water proofing compound for incorporating concrete.Make. Fosrac, BASF, SIKA 58 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in in lintels upto 1.5m clearspan, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating. complete as specified and directed. 59 Kerb stone : Providing precast cement concrete using Type-B1, 1:2:4 20 mm graded aggregatein window or doorcills, lintels, bressumers, steps, quoin blocks (for use with ma- sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets,etc. with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4. Complete with joints to match . Complete all as specified and directed. 60 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in roofkerbs or mud stops, rounded orchamfered on edges.complete as specified and directed. 61 PCC : Plain Cement Concrete (1:2:4) Type B2 using 40 mm graded aggregate in foundations, floors, filling and mass concrete, Complete all as specified and directed . 62 RCC : Reinforced cement concrete (Type B1, 1:2:4 with 20 mm aggregates) in columns, pillars, piers, posts etc. Complete all as specified and directed. 63 REINFORCEMENT : Mild steel(TMT) bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and directed. . 64 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 100 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 65 SWG PIPE : Supply & fixing of 100 mm dia Salt Glazed Stoneware drain pipes Grade A, including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 66 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 150 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 67 SWG PIPE : Supply & fixing of 150 mm dia Salt Glazed Stoneware drain pipeslaid in trenches including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 68 Earth work in excavation of all kind of soils by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Complete all as specified and directed . 69 Returning, filling in of excavated soils, including spreading, levelling, watering and well ramming in layersnot exc 25 cm. 70 PVC PIPE : Supply and Fixing of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid or fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 71 PVC PIPE : Supply and Fixing of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 72 Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit iring, etc., and making good, cutting not exc 10 cm girth. Complete all as specified and directed. 73 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces. Complete all as specified and directed. 74 S & F ofG.I. Tubes of Size 40 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 75 S & F ofG.I. Tubes of Size 25 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 76 S & F ofG.I. Tubes of Size 1/2‘’(15 mm), medium grade including all fittings to walls and ceilings or in floors/trenches. 77 Supply & Fixing Rotational moulded polyethylene water storage tanks (PVC cylindrical vertical with closed top) hoisted and fixed in position 1000 lit capacity. make : Syntex 78 BALL VALVES : 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Complete all as specified and directed. 79 NAHANI TRAPS : Supply & Fixing ofCI Nahani traps 100mm with grating including jointing to went pipe with CC 1:2:4complete all as specified and directed at site. 80 GULLY TRAP : M&L for PVC/SWR gully traps, of size 125 mm x 110 mm all as directed and specified. 81 GRATING : Supply and fixing of grating doom 100 mm dia. of PTMT (min. weight 25 gms) 82 PVC D/E PIPE CONNECTION :Supply and fixing of PVC Double End Pipe connection.in repairs, size:15mm with end nuts & washers of length 600 mm. Make : Kohinoor. Complete all as specified and directed. 83 ALUMINIUMPARTITIONS : Supply and fixing complete of anodised aluminium powder coated frames for partition frames and windows etc. all complete as directed by E.I.C. 84 ALUMINIUM WINDOW SHUTTERS : Supply and fixing complete of anodised aluminiumwindow and ventilator shutters powder coated fixed type without sash bar ,aluminium section weighing 0.55 kg/m including necessary jointig cleats, glazing clips, rubber neoprane packing, handles 2 nos. in each door, hinges, anodised aluminiumsnap beading, screws etc. complete all as directed by E.I.C. 85 HINGES : Supply and fixing of extruded Al. alloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-21 of size 125mmincluding all as specified and directed . 86 Antique aldrop : Supply and fixing of 200 mm long Antique model Brass mixed heavy alloy, sliding door bolt withsand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed.All as specified and directed and as approved by EIC. 87 Brass hinge: Supply and fixing of extruded brassalloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-11 of size 125mmincluding.All as specified and directed and as approved by EIC.. 88 Antique tower bolt : Supply and fixing of Antique model Brass mixed heavy alloy, barrel tower bolts of extruded section of size 200 mm and fixed all as directed.All as specified and directed and as approved by EIC. 89 Antique Door handle : Supply & fixing of Extruded Antique model Brass mixed heavy alloy, cast type polished bright handles 150 mm long, Complete all as specified and directed 90 TOWER BOLT : Supply and fixing of Aluminium anodised, barrel tower bolts of extruded section of size 200 mm and fixed all as directed. 91 BOW HANDLE: Supply & fixing of Extruded aluminium alloy handles 150 mm long, fabricated type, anodised. Complete all as specified and directed 92 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be easured separately), removing materials to store for keeping in safe custody for reuse at site and making good. 93 Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) 94 point wiring:S&F / Drawing of cables in PVC pipe,OneLight point or onefan point controlled by one switch with cables 1.5 sq.mm size of copper conductor cables FR PVC single core sheathed cable 95 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 5 amps independent, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 96 point wiring: S&F /Drawing of cables to One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 97 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 15 amps independent, with cables 4.0 sq.mm size of copper conductor cables FR PVC sheathed. 98 S & F of ceiling rose,3 phase/PVC/Polycorbonate, Isolate body 99 S & F ofswitch modular type of one module, 6 amps 100 S & F ofsocket, 2/3 pin combined, 6 amps, 2 Module 101 S & F ofswitch modular type of one module, 16 amps 102 S & F ofsocket, 2/3 pin combined, 16 amps, 2 Module 103 S & F ofFan step regulator 120 W, 2 Module 104 LED LUMINAIRE :Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/ Halonix 105 S & F of round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 106 S & F of LED tube lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 107 LED Street Light :Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/Halonix.complete all as specified and directed 108 Exhaust Fan: Supplyand Fix Exhaust Fan made of sturdy Engineering plastic complete with Lauvers, Shutteers, voltage 230 V,50 HZ, RPM 1200, Copper winding ofsweep 250mm.complete all as specified and directed. 109 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) 110 Industrial socket plug: Supply and fixing of 240 V, 20 amps, single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB. 111 MCB :Supply and fixing of MCB / Isolator, 240 V, single pole 40 amp 112 MCB :Supply and fixing of MCB / Isolator, 240 V, double pole 40 amp 113 MCB D.B : S & F of Sheet Metal enclousers for D.B ofsingle doorof SPN,8 way with 200A rated bus bar,240V 114 MCCB: Suppply and fixing of MCCB 3 pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. 115 S & F of Modular metal flush box 6 module 116 S & F of Modular white cover plate with frame 3 module 117 S & F of Modular white cover plate with frame 4 module 118 S & F of Modular white cover plate with frame 6 module 119 S & F of Modular white cover plate with frame 8 module 120 EARTHING : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.complete all as specified and directed 121 Earth continuity conductor : Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip. complete all as specified and directed 122 Dismantlng ofAsbestos cement (corrugated,semi corrugated, etc.) sheets in roofcoverings. Sheets shall be deposited to stores as directed. 123 Cutting or uprooting grass on old CC/brick tiles or on old mud phuska,and Taking down old Taf felt and loose material from the roof, cleaning the bitumen surface by wire brushing, washing down & disposing the pealed off tar felt muck etc. for complete as directed. removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster. Complete as specified and directed. 124 Surface painting : Removal of old tarfelt sheets,Wire brushing and cleaning top surface of roof tops and surface painting, with a layer of bitumen primer for bitumen membrane @ 0.50 ltr/sqm by the same membrane manufacturere of density at 25° C, 0.87-0.89 Kg/ltr and viscosity 70-160 cps and then left the surface 4 to 8 hours for drying.Complete as specified and directed. 125 Bitumen Tack coat / Seal coat : Applying surface bitumen coat Seal / Tack coatwith lndustrial bitumen 85/25 forwaterproofingtreatments at the rate of 1.2 kg / sqm . 126 Water proofing treatment (M&L) : Rendering water proofing treatment to RCC roof slabs including vertical surfaces with APP based polymetric membrane sheet, minimum 3 kg/sqm and minimum 3.0 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) evenly laid on primed surfaces by forced applicationby torch on treatment. The vital physical and chemical parameters of the membrane shall be : Tensile strength in longitudinal and transverse direction at 23° C as 650/450/5 cm.Tear strength in longitudinal and transverse direction as 300/250 N. Softening point of membrane not less than 150° C. Cold flexibility shall be up to 2° c when tested in accordance with ASTM, D-5147. The laying of membrane shall be done through the authorised applicator of the manufacturer of membrane. Membrane make : STP / Dr. Fixt / IWL as approved by EIC. 127 Carrying and disposal of debris : Removing building materials etc. to a distance of 1.5 KM or under including loading, unloading and stacking at the destination. Complete all as specified and directed at site. 128 Rolling shutter : S&F ofSteel rolling shutters 1.25 mm thickness of lathe, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle. Complete all as specified and directed. 129 Rough excavation notexceeding1.5 m deepin drains etc in loose/soft soils andgetting out 130 Scarifying : Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc.400 sqm and the thickness Exc 50 mm and n.exc 100 mm deep 131 Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 132 Macadam : Premix bituminous, macadam with paving bitumen any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less).Complete all as specified and directed. 133 Pot holes : Repair to pot holes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth,making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadamusing paving bitumen, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cu m of stone chippings,6.3 mmsizeand again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm.Complete all as specified and directed. 134 Preparing Black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 135 Applying evenly a priming/tack coat with bituminous primer using paving bitumen at 5kg per 10 sq metre. Complete as specifiedand directed. 136 Bituminous premixed carpet, 2.5 cm consolidated thickness, with 0.34 cu.m. of stone chippings mixed with 18.25 kg of binder (paving bitumen)per 10 sq.m and mixed in mechanical hot mix plant and laid with mechanical paver and rolled using power roller 8-10 T capacity and compacted to required camber and gradient to uniform smooth surface. Complete as specifiedand directed. 137 Supply and fixing of Machine cut cudappah stoneslab 20-25mm thick over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shadeof the slab including rubbingand polishing complete. 138 Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint and application of priming paint plaster coat. 139 Rendering synthetic enamel painting on new Steel surfacesof any description over 10 cm width or girth- TWO coats including one coat of red oxide Zinc chrome paint. Make: Asian paints/Berger 140 Complete removal existing treatment of of white washing onsurfaces of walls/ concrete. 141 Complete removal existing treatment of of white washing on surfaces of ceilings. 142 CHALK WHITENING : M&L - Chalk whitening (white cement-based, water-resistant, white wall putty) of plastered surfaces as preparatory to distempering on wall surfaces, Make : Birla wall care, complete all as specified & directed. 143 PRIMER : Priming plastered and other surfaces with alkali resistant priming paint. Make : Asion/Dulux- all as specified and directed . 144 WHITEWASH ON CEILINGS : M&L - White washing on ceilings- on old decorated surfaces- including preparation of surfaces – ONE coat of White Wash-complete all as directed. 145 WHITEWASH ON WALLS : M&L - White washing on Walls – on old decorated surfaces- including preparation of surfaces - TWO coats of White wash - complete all as directed. 146 PLASTIC EMULSION PAINT:Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint-complete all as directed. Make: Asian -Apcolite / Dulux-promise. 147 OBD : M&L - Rendering Oil Bound Distempering on old surfaces -including preparation of surfaces on walls - TWO Coats of OBD - complete all as directed. Make : Asian-tractor Uno / Berger-Butterfly / Indigo-gold. 148 External weather proof painting on walls : Material & Labour for applying Two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces. all as specified and directed, Brand : Asian apex,Berger weather shield, Nerolac Rain coat. 149 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting onOld painted Steel surfaces- surfaces of any description over 10 cm width or girth including preparation of surfaces-TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 150 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on Old painted Steel surfaces- surfaces of any description n.exc 10 cm width or girth including preparation of surfaces- TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 151 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on wooden surfaces - old surfaces of any description over 10 cm width or girth including preparation of surface - TWOCoats- all as specified and directed-Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 152 FRENCH POLISHING : French polishing on old surfaces of any description, width or girth –including cleaning and preparing the surface- One or more coats. all as specified and directed. Make : Sheenlac, sealer 153 Supply and fixing of Safety lever locks mild steel with 4 levers for rolling shutters as directed. 154 Fan Hook: Supply and Fixing of Fan hook with double anchor bolt complete fixing as per instructions of EIC. 155 IWC : IWC of approved make fixed with P trap Make: Hindware/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 156 CONCEALED FLUSHING SYSTEM : Wall mounted concealed flushing system (including frame, control plate and installation kit) with dual flush mode of capacity 10 ltrs. Make: Jaquar(Solo)/ Parryware(Prime)/ Cera(Fountain). Complete all as specified and directed. 157 MIRROR : Mirror 5 mm thk. with bevelled edge fixed with concealed screws Make: Saint Gobain/ Nilkamal/ Casa Gold. Complete all as specified and directed. 158 Switch board box with frame plate and cover plate , metal flush box18 module: Supply and Fixing of covering plates with Metal Flush box andcover plate frames of 18 module of make Legrand/ Schneider/ Havellscomplete all as specified by the EIC 159 Concertina coil & 6 straight RBT strands : Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina cross type fencing, GI steel plate & GI core wireon wall top using concertina coils stretched to approx.6 meters length at site and clipped with three nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips, R.B.T clips etc.). Including additional three horizontal R.B.T strands to be fixed with vertical portion of MS angle supports as directed in site. Complete all as specified and directed at site. 160 Accoustic sheets : supply and fixing of choice colourPolyester Fiber Acoustic Board / tiles, Thickness: 12mm, for insula-tion and accoustic purposes, 60x60 cm in size, fixed to wall / ceiling surfaces on snap grid orwith nails to timber frame work or with Z bar/clips etc as specified by manufacturer.Complete all as specified and directed. 161 Floor mat: supply and fixing of choice colourNylon carpet for floors minimum 6 mm thicknesshaving better accoustic co-efficient ,fixed to floor with approved adhesiveas specified by manufacturer.Complete all as specified and directed. 162 ACP wall lining : Supply and fixing of decorative choice colour solid finished Aluminum composit panel 4.0 mm thick sheeting on external wall surfaces upto 12.0 mter heights fixed over aluminium/MS framed wall surfaces as specified by manufacturer. Cost includes ACP panel, frame work, jointing glue and scafolding etc. Complete all as specified and directed. 163 UPVC window (Single glazed panel shutter & fixed wire mesh panel): Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series)frame 47 x 50 mm & sash 47 x 68 mm both havingwall thickness of 1.9 ± 0.2 mm and single glass paneglazing bead of appropriate dimension (Area ofwindow upto 0.75 sqm.) comprising of uPVC multi-chambered frame, sash and mullion (where everrequired) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel sectionmade from roll forming process of required length(shape & size according to uPVC profile), uPVCextruded glazing beads of appropriate dimension,EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casementhandles, G.I. fasteners 100 x 8 mm size for fixingframe to finished wall, plastic packers, plastic capsand necessary stainless steel screws etc. Including SS wire mesh panel with aluminium beeding fixed to outer face window using adjustable /removable clips. Profile offrame & sash shall be mitred cut and fusion weldedat all corners, mullion (if required) shall be alsofusion welded including drilling of holes for fixinghardwares and drainage of water etc. After fixingframe the gap between frame and adjacent finishedwall shall be filled with weather proof siliconsealant over backer rod of required size and ofapproved quality, complete all as specified anddirected by Engineer-in-Charge. 164 WALL TILES : Supply & fixing of Coloured digital glazed ceramic tiles in vertical surface 300x600 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell. 165 PVC door frame : S & F of solid WPVC Door Frame of size 100x60 mm heavy density of 11100 kg/cum and high quality PVC laminated of choice colour. Complete all specified and directed. 166 PVC door shutter : S & F of Factory Made Solid WPVCDoor Shutter with wood free EPS, 32 mm thick, heavy density 700 kg/cum and high quality PVC laminated on both side of choice colour. 167 Staircase railing : Supply and fixing of designed Stainless steel hand railing not less than 0.8 mtr height for stairs, balconies etc. using SS grade 304/316 members for balusters & rails etc. and covered with 12 mm thick tampered toughned glass. Design & model shall be as decided by EIC. Cost inclusive of glass, design and other mountings. Complete all as specified and directed. 168 Handicap grab bar : S&F of stainless steel anti slip vertical swing handicap bath room grab bar/rail with paper holder of min. 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 169 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 170 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 0.45 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 171 Wood Door : Supply and fixing of modern & designer soildTeakwood door shutters for Main Doors 32 mm finished thickness as decided by EIC . 172 EWC : Supply and fixing ofItalian Collection ceramic Floor Mount Western Commode, Rim less, One-piece for Bathrooms with Syphonic vortex Flushing system and soft closing seat cover including connection pipe.Make : Jaquar Fusion, Hindware Fabio, Cera cinova 173 WASH BASIN : Supply and fixing of Under counter Wash basin rectangle of approved make along with waste coupling, waste pipe and connection pipe, brackets etc. Make : Jaquar(Continental)/ Cera(campa)/ Parryware(Aqiline). Complete all as specified and directed. 174 URINAL : Supply and fixing ofSensor Urinal pan of approved make with auto flushing system including connection pipe, waste coupling and waste pipe Make: Jaquar(Aquisense)/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 175 PILLAR COCK : S&F ofsensorbased table top model Pillar cock with auto closing system of make: Jaquar / Hindware/ Cera. Complete all as specified and directed. 176 CONCEALED STOP COCK : S&F of CP Concealed stop cock of make : Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 177 2 WAY ANGLE COCK : S&F ofCP 2 way angle cock Make: Parryware(Uno)/ Cera(Fountain)/ Jaquar(Solo). Complete all as specified and directed. 178 EWC JET FAUCET : S&F of EWC jet faucet of make: Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 179 BIB COCK : S&F ofCP Bib cock of make: Jaquar(Solo)/Parrywaare(Uno)/ Cera(Fountain). Complete all as specified and directed. 180 SOAP DISH : S&F of SS soap dish of make Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 181 Hand drier: Supply and fixing of plastic Automatic Hot air drierfor bath rooms of approved make. Make :Orchid / Dolphy / Bajaj. Complete all as specified and directed. 182 Liquid soap dispensar: Supply and fixing of Liquid soap dispensar for bath rooms of approved make. Make :Jaquar / Orchid / Dolphy. Complete all as specified and directed. 183 Toilet paper holder: Supply and fixing of stainless steel single toilet paper roll holder of approved make. Make :Jaquar continental / Parryware sigma/ Cera Icon. Complete all as specified and directed. 184 Urinal partition : Supply and fixing of HPL (High-Pressure Laminate) urinal partitions using 12 mm thick compact board of width 400 to 500 mm and height 1200 mm of approved make and fixing with stainless steel brackts. Complete all as specified and directed. 185 Bldg.Expansion joint : Preparation of joint by grinding of groove surfae, remoal of dust, providing polymer mixed cement mortar on both sidea of groove and crack filling if any in floor level, fixing of baker rod 25x25 mm to control depth of groove, Providing and applying Nitoseal PU50 of Fosroc or equivalant having MAF 25% or above to the groove 25x12 mm. Including fixing / covering of joint with APP based polymetric membrane sheet sufficient width. Complete all as specified and directed at site. 186 Forming V grooves on granite surfacesn,exc 10mmdeep and n exc 10mm on face in steps, cooking platform, and other similar situations etc. 187 Hiring / Engage of JCB for cleaning, moving and loading materials like sand, gravel, or demolitionand removal of debris and other miscellaneous purposes as directd. The rate includes diesel and driver required to run the vehicle. 188 Carpet grass : Supplly and laying of carpet grass on levelled soil surface including preparing the soil bedby loosning the base ground 100 mm thick and removing old unwanted grass if any and necessary watering as directed. 189 Supply and laying of red earth / soil in loose state which is free from debris, grass and other vegitation to be used for gardening purposes as directed. 190 Architectural design : Before commencement of work Contractor should take architectural consultancy servies for entrance arch at the entrance gate, building front elevations and garden designs by authorised institutions / authorised Designer. Complete all as directed by EIC
Contract Date: May 16, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 4
19.
Petroleum and Natural Gas #11060066 Technical Bid
Supply Of Big Bag Unloading System Design, Engineering, Manufacturing, Procurement Of Materials And Bought Out Components, For Big Bag Unloading System As Per Material Requisition For Numaligarh Refinery Limited, Golaghat, Assam, India , Complete Big Bag Unloading System As Per Specifications Enclosed With The Material Requisition (Document No. Tp-1P30a-Me-Rfq-0052). , Per Diem Rate For Supervision Sevices Of Installation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Per Diem Charges Upto 8 Hrs On Normal Working Days. ( Bidders To Quoteunit Rate For Diem Charges ) , Unit Rate Forsupervision Services Of Installation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour (Beyond Normal 8 Hours On Normal Working Days). ( Bidders To Quote Over Timerate Per Hour ) , Unit Rate Forsupervision Sevices Ofinstallation And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour For Work On Weekly Off Days / Holidays (As Applicable To Refinery Site). ( Bidders To Quote Over Timerate Per Hour )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
20.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
21.
Power #11049461 Technical Bid
Tender For Design, Engineering, Supply, Installation, Testing, Commissioning And Annual Maintenance Service For Flood Early Warning System For 37.5 Mw Parnai Hep- 1 Sensor Station For Parnai Project 2 Radar Type River Level Sensor With Tilt Meter Including All Accessories, Software & Mounting Arrangement 3 Radar Type River Velocity / Flow Sensor With Tilt Meter Including All Accessories, Software & Mounting Arrangement 4 Sensor Data Acquisition Equipment Including Data Loggers, Modems, Etc. With All Accessories 5 Vsat Communication Setup Including All Hardware, Software, Fixed & Recurring Fees, Etc. 6 Terrestrial Communication Setup (Gsm/Gprs Modem / Multi-Sim Internet Generator, Etc.) Including All Hardware, Software, Fixed & Recurring Fees 7 Prefabricated Enclosure With Internal & External Lighting, Fire Detection & Suppression System, Etc. And Associated Civil Works 8 Hybrid Spv Based Power Supply System With Li-Ion (Lifepo4) Batteries And All Accessories Including Cables, Distribution Arrangement Including Protection, Control & Monitoring Systems 9 Command & Control Centre 10 Vsat Communication Setup Including All Hardware, Software, Fixed & Recurring Fees, Etc 11 Terrestrial Communication Setup (Gsm/Gprs Modem / Multi-Sim Internet Generator, Etc.) Including All Hardware, Software, Fixed & Recurring Fees 12 Prefabricated Enclosure (Porta Cabin) Along With Internal & External Lighting, Fire Detection & Suppression System, Air Conditioning, Access Control System, Etc. And Associated Civil Works 13 Hybrid Spv Uninterrupted Power Supply System With Vrla Batteries (05 Days Backup) And Associated Cables & Cabling Accessories, Distribution Arrangement Including Protection, Control & Monitoring Systems.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu and Kashmir View Result →
22.
Petroleum and Natural Gas #11010772 Technical Bid
Supply Of Analysers And Cabinets (Lot 2) Design, Engineering, Manufacturing, Procurement Of Materials And Bought Out Components, For Supply Of Analysers And Cabinets (Lot 2) As Per Material Requisition For Numaligarh Refinery Limited, Golaghat, Assam, India , Supply For Analysers And Cabinets As Per Mr No - 200663C-000-Mr-1562-0004 And Details Given Below:- , Hydrocarbon Analysers Along With Other Accessories And Cabinet/ Rack As Applicable. (Tag No - 1P30-At-220301) , Third Party Inspection Charges , Scope As Per Material Requisition. , Transportation: For Indegenious Bidders : Inland Transportation Charges By Road Of All Supplies From Vendor’S Works / Shop To Project Site, Numaligarh Refinery, Golaghat, Asaam/ Rail Transportation Up To Nmgs/Numaligarh Refinery Project Site. (Excluding Gst) , Mandatory Spares For Item No 10.00, Tag No - 1P30-At-220301 , Each Type Of Power Supplies, Fuses, Gaskets, Detectors, Bulbs, Repair Kits Etc. , Sample Handling System Components If Not Listed Below (As Applicable) , Sample Flow Meter (As Applicable) , By Pass Flow Meter (As Applicable) , Solenoid Valve (As Applicable) , Communication Board (As Applicable) , Display Unit – Each Type (As Applicable) , Cpu Board – Each Type (As Applicable) , Sensor Electronic – Each Type (As Applicable) , Modulation Unit – Each Type (As Applicable) , Sample Cell (As Applicable) , Sensor – Each Type (As Applicable) , O Ring (As Applicable) , Thermal Fusses (As Applicable) , Heating Cartridge (As Applicable) , Thermal Trip (As Applicable) , Analogue Module – Each Type (As Applicable) , Filter Membrane (Pack Of 25) (As Applicable) , Fuse – Each Type (As Applicable) , Specific Gravity Analysers With Accessories Along With Rack / Cabinet As Applicable (Tag No - 1P30-At-278201) , Third Party Inspection Charges , Scope As Per Material Requisition. , Transportation: For Indigenous Bidders : Inland Transportation Charges By Road Of All Supplies From Vendor’S Works / Shop To Project Site, Numaligarh Refinery, Golaghat, Assam/ Rail Transportation Up To Nmgs/Numaligarh Refinery Project Site. (Excluding Gst) , Mandatory Spares For Item No 20.00, Tag No - 1P30-At-278201 , Each Type Of Electronics, Display Units, Power Supplies, Fuses, Gaskets, Sensors, Sensing Elements, Detectors, Bulbs, Repair Kits Etc. , Sample Handling System Components. (As Applicable) , Calibration Kit (As Applicable) , Hydrocarbon Analysers Along With Other Accessories And Cabinet/ Rack As Applicable (Tag No - 1P30-At-563801) , Third Party Inspection Charges , Scope As Per Material Requisition. , Transportation: For Indegenious Bidders : Inland Transportation Charges By Road Of All Supplies From Vendor’S Works / Shop To Project Site, Numaligarh Refinery, Golaghat, Assam/ Rail Transportation Up To Nmgs/Numaligarh Refinery Project Site. (Excluding Gst) , Mandatory Spares For Item No 30.00, Tag No - 1P30-At-563801 , Each Type Of Power Supplies, Fuses, Gaskets, Detectors, Bulbs, Repair Kits Etc. , Sample Handling System Components If Not Listed Below (As Applicable) , Sample Flow Meter (As Applicable) , By Pass Flow Meter (As Applicable) , Solenoid Valve (As Applicable) , Communication Board (As Applicable) , Display Unit – Each Type (As Applicable) , Cpu Board – Each Type (As Applicable) , Sensor Electronic – Each Type (As Applicable) , Modulation Unit – Each Type (As Applicable) , Sample Cell (As Applicable) , Sensor – Each Type (As Applicable) , O Ring (As Applicable) , Thermal Fusses (As Applicable) , Heating Cartridge (As Applicable) , Thermal Trip (As Applicable) , Analogue Module – Each Type (As Applicable) , Filter Membrane (Pack Of 25) (As Applicable) , Fuse – Each Type (As Applicable) , H2o Analyser Along With Other Accessories And Cabinet/ Rack As Applicable (Tag No - 1P30-At-793101) , Third Party Inspection Charges , Scope As Per Material Requisition. , Transportation: For Indegenious Bidders : Inland Transportation Charges By Road Of All Supplies From Vendor’S Works / Shop To Project Site, Numaligarh Refinery, Golaghat, Assam/ Rail Transportation Up To Nmgs/Numaligarh Refinery Project Site. (Excluding Gst) , Mandatory Spares For Item No 40.00, Tag No - 1P30-At-793101 , Each Type Of Display Units, Power Supplies, Gaskets, Bulbs, Repair Kits Etc. , Sample Handling System Components (As Applicable) , Sensor And Detector –1 No. (As Applicable) , Electronic Card – Each Type (As Applicable) , Fuses (As Applicable) , Flow Indicator & Switch(As Applicable) , Oxygen Analysers Along With Other Accessories And Cabinet/ Rack As Applicable (Tag No - 1P30-At-893203) , Third Party Inspection Charges , Scope As Per Material Requisition. , Transportation: For Indegenious Bidders : Inland Transportation Charges By Road Of All Supplies From Vendor’S Works / Shop To Project Site, Numaligarh Refinery, Golaghat, Asaam/ Rail Transportation Up To Nmgs/Numaligarh Refinery Project Site. (Excluding Gst) , Mandatory Spares For Item No 50.00, Tag No - 1P30-At-893203 , Each Type Of Electronics, Gaskets, Detectors, Bulbs, Etc. , Sample Handling System Components (As Applicable) , Furnace Assembly (As Applicable) , Thermocouple (As Applicable) , Sensor Board (As Applicable) , Each Type/Rating Of Fuses (As Applicable) , Thermistor Assembly (As Applicable) , Ceramic Filter (As Applicable) , Processor Card (As Applicable) , Power Supply Card (As Applicable) , Display Board (As Applicable) , Cell Replacement Kit (As Applicable) , Any Other Card (As Applicable) , Calibration Kit (Regulator For Calibration Gas Cylinder And Calibration Rotameter) - One Set For Each Of The Units Where O2 Analyser Installed. (As Applicable) , Specific Gravity Analysers With Accessories Along With Rack / Cabinet As Applicable (Tag No - 1P31-At-278401) , Third Party Inspection Charges , Scope As Per Material Requisition. , Transportation: For Indigenous Bidders : Inland Transportation Charges By Road Of All Supplies From Vendor’S Works / Shop To Project Site, Numaligarh Refinery, Golaghat, Assam/ Rail Transportation Up To Nmgs/Numaligarh Refinery Project Site. (Excluding Gst) , Mandatory Spares For Item No 60.00, Tag No - 1P31-At-278401 , Each Type Of Electronics, Display Units, Power Supplies, Fuses, Gaskets, Sensors, Sensing Elements, Detectors, Bulbs, Repair Kits Etc. , Sample Handling System Components (As Applicable) , Calibration Kit (As Applicable) , Charges For Services For Site Supervision During Erection & Commissioning And Training To Client Personnelat Nrl Site Note : Same Rate Is Applicable During Warranty/ Defect Liability Period After Successful Commissioning Of The Analyser, Visits (2 Periodic Visits) Of The Expert Is Mandatory For Performance Monitoring/ Observation/ Calibration, Troubleshooting, Advisory Service On Improvement Etc. , Per Diem Rate For Supervision Sevices Of Erection And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Per Diem Charges Upto 8 Hrs On Normal Working Days. ( Bidders To Quoteunit Rate For Diem Charges ) , Unit Rate Forsupervision Services Of Erection And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour (Beyond Normal 8 Hours On Normal Working Days). ( Bidders To Quote Over Timerate Per Hour ) , Unit Rate Forsupervision Sevices Of Erection And Commissioning / Performance Testing / Training To Client Personnel At Site By The Expert Of Oem/ Oem’S Representative As Per Details Mentioned In Material Requisition For Quoted Items As Per Enclosed Instructions To Vendor Overtime Rate Per Hour For Work On Weekly Off Days / Holidays (As Applicable To Refinery Site). ( Bidders To Quote Over Timerate Per Hour )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
23.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
24.
Defence #10969895 Price Bid
Tender for Dismantling Water Tanks Exc 500 Ltr But Not Exc 1000 Ltr And Removing To Store Or Issued To Contracror Under Sch Of Credit Complete All As Specified And Directed. , Taking Up Or Down 25 Or 32 Mm Dia Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Down Shutters Of Any Description Exc 2 Sqm Of Doors Each Complete All As Specified And Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises, Complete All As Specified And Directed. , Demolition Of Cement Concrete (Un-Reinforced) In Ground Floors And Pavings N Exc 15 Cm Thickness (Below Or Above Ground Levelr All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) Of Any Description And In Any Position Not Otherwise Specifically Provided For All As Specified And Directed. , Dismantling Of Plain Or Corrugated Steel Sheeting Any Gauge, Thickness As In Roof Covering Complete All As Specified And Directed , Use And Waste Flat Form Work To Vertical Faces Of Drain/Retaining Wall And Similar Work . , Taking Down Chowkats Or Frames With Shutter (Without Taking Off Shutter From The Frame) Not Exc 1.50 Sqm Each Including Iron Mongeries Complete All As Specified And Directed. , Material And Labour For Providing Cement Concrete 1:2:4 Type B-1 Using 20 Mm Graded Aggregate ) In Plinth Walls Or Retaining Walls,Drain Walls, Any Thickness, Size Or Shape Including Pilasters, Buttresses Columns, Pillars, Boundary Pillars And Posts (Including Caps And Bases) , M&L For Cement Concrete Type B-2, 1:2:4 (Using 40Mm Graded Agg) As In Surface Channels And Drains Complete All As Specified And Directed. , Extra For Forming Fair Finished Drain Or Channel 30 Cm Inner Girth In Cement Concrete, Using Extra Cement, Including Forms, Moulds, Mi- Tred/Stopped Ends Etc , S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing. Complete All As Specified And Directed By Engr-In-Charge. , S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed By Engr-In-Charge. , Supply And Fix 30Mm Thick Single Piece, Coloured Abc (Acrylonitrile Brutadine Styrene) Coated, Puf Filled Door Shutters With Puf (Poly Urethanefoam) Insulation Of Minimum Density 40 Kg/Cum Filled In Between Two Abs Sheets Of Thickness 1.2Mm (Min), Border Covered With Insitu Pasted Abs Strips Of Width Equal To Thickness Of Door Shutters, 1.2Mm Thickness, Reinforced With Two Number 10Mm Ctd Bars, PreEmbedded With Wooden Blocks Of Suitable Sizes For Receiving Hinges, Tower / Sliding Bolts, Towel Rails, Handles Etc, With/Without Embossed Pattern Completed All As Specified And Directed. , S&F 150Mm Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And Fixed, Complete All As Specified And Directed By Engr-In-Charge. , S&F 300Mm Mild Steel Sliding Door Bolts, Plate Type, Stove Enamelled Black, With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, Four On Bolt Plate And Two On Staple Plate And Fixed, Complete All As Specified And Directed By Engr-In-Charge. , S&F 75Mm Butt Hinges, Mediam Weight, Cold Rolled Mild Steel And Fixed Complete All As Specified And Directed By Engr-In-Charge. , S&F 150Mm Aluminium Handles, Cast Type, Anodised Complete All As Specified And Directed By Engr-In-Charge. , S&F Galvanised Mild Steel Wire Cloth, 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18Mm And Fixed With Tinned Tacks, Or Galvanised Wire Staples , S&F Powder Coated Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified , S&F Powder Coated Anodised Aluminium Window And Ventilator Shutters Powder Coated (Min Thickness 50 Micron), Fixed Type Without Sash Bar, Aluminium Section Weighing 0.55 Kg/M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws Etc. Complete All As Specified , M&L For Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified , M&L For Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified , S&F Tank Connector With All Fitting Suitable To 32Mm Dia Ppr Pipe Complete All As Specified And Directed. , S&F In Repair 32Mm Dia Waste Pipe For Whb/Sink Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Angle Valve, Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle And Fixedcomplete All As Specified And Directed. , M&L For 75Mm Thick Plain Cement Concrete Type C-2, 1:3:6 (Using 40Mm Graded Stone Agg) As In Plinth Protection Complete All As Specified And Directed. , M&L For 40 Mm Thick Plain Cement Concrete Type B-1, 1:2:4 (Using 20Mm Graded Stone Agg) As In Sub Base, Floors And Pavings Complete All As Specified And Directed. , M&L For Non-Skid Ceramic Coloured Tiles 7 To 8Mm Thick (Square/Rectangular) Area Of Each Tile Exc 0.06 Sqm But Not Exc 0.11 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engr-In-Charge. , M&L For Joint Free Non - Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Area Of Each Tile Exc 0.18 Sqm But Not Exceeding 0.38 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed. (Note: Colour And Pattern Of Tile Will Be Decided By Ge/ Engr-In-Charge. Contractor Will Brought The Tiles Only After Approval Of Colour And Pattern By Ge/Engr-In-Charge). , M&L For Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces With Cm 1:4 Complete All As Specified. , M&L For Screed Bed Or Bedding Layer Of Mortar 15Mm Thick For Laying Floor Finishes In Cm 1:6, Complete All As Specified And Directed. , M&L For Preparing Plastered Or Unplasterd Newly Surface Of Any Description With Three Coat Of White Wash On Walls Surfaces. , Supply And Fix Sheet Glass 4Mm Thick Ordinary Quality And Glazing With Oil Putty In Squares N.Exc 0.50 Sqm In Each Pane, Complete All As Specified And Directed. , M&L For Preparation Of Old Steel Surfaces Of Any Description, Over 10Cm In Width Or Girth,Not Otherwise Described And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. , S&F 32Mm Dia 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or Infloors Etc. Complete All As Specified And Directed. , S&F 25Mm Dia 3-Layer Pp-R Polypropylene Random Copolymer) Concealed Pipes Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. Complete All As Specified And Directed. , S&F 32Mm Dia Pp-R Gate Valves (Brass Insert) As Per Requirement Of The Site Complete All As Specified And Directed. , S&F 750 Ltrs Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Complete All As Specified And Directed. , S&F 1000 Ltrs Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Fancy Type Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Pillar Taps, Cast Copper Alloy, With Capstan Heads, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe And Fixed Complete All As Specified And Directed. , S&F Waste Coupling Of Ptmt (Half Or Full Threaded) (Minimum Weight 32Mm - 45Gms/40Mm-60 Gms) Complete All As Specified And Directed. , S&F Repairs Grating Doom 100Mm Dia Of Ptmt (Minimum Weight 25Gms) Complete All As Specified And Directed. , S&F In Repair Pvc Connections 15Mm Size With Ptmt Nuts Of Length 600Mm Complete All As Specified And Directed. , S&F In Repairs Vitreous China Squatting Pan, ‘Orissa Pattern, Size 580 X 440 Mm White, With Integral Foot Rests (Excluding Flushing Cistern And Flush Pipe) Squatting Pan Including Connection To Trap, And To Flushing Pipe, Anti-Syphonage Pipe, Etc. Complete Including Making Good To Floor Complete All As Specified And Directed. , S&F In Repairs Pvc Valveless, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Bracket High Or Low Level Fluslhing Cistern (Exclusive Of Brackets), And Connections To Pipes And Fixing Of Chain And Pull, Or Lever, If Any Complete All As Specified And Directed. , S&F In Repairs Vitreous China Wash Basin, White, Flat Back, Size 550X400mm Excluding Taps, Waste, Chain And Plugs But Including Brackets Complete All As Specified And Directed. , Supply & Fix Aluminium Anodised Barrel Tower Bolt 150 Mm Long Of Extruded Section Etc Complete All As Specified And Directed. , Supply & Fix Aluminium Alloy, Anodised, Sliding Door Bolts 250Mm Size With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheets , Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast Aluminium Alloy And Fixed Etc Complete All As Specified And Directed. , Supply And Fix Ms Butt Hinges Medium Weight, Cold Rolled 100Mm Size Complete All As Specified And Directed. , Supply & Fix Extruded Aluminium Anodised Alloy Handles Fabricated Type 150Mm Long Complete All As Specified And Directed. , Taking Down Copper/Aluminium Point Wiring (Light, Fan, Socket Or Power) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting Etc. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit (Credit For Above Items Should Be Made As Per Conditions Separately) And Making Good Disturbed Surfaces Of Walls, Floors, Etc. , M/L For Point Wiring In Casing Caping With 1.5Sq Mm Frls Pvc Insulated Unsheathed Single Core Multithreaded Copper Conductor Cable 1100 Volts Grade Incl 1.5 Sq Mm Pvc Insulated Unsheathed Copper Conductor Cable As Earth Continuity Conductor Drown Through In And Incl Casing Caping With Its Accessories Pressed Steel Terminal Box Incl 3Mm Thick Isi Marked Laminated Sheet Cover For Fixing Switches/Socket/Regulators Etc For The Following: -One Light/Fan Point Controlled By One No Piano Type Switch 5 Amps Single Pole One Way , One Socket Outlet 5/3 Pin 6 Amps Controlled By One Switch On The Same Board. , One Socket Outlet 5/3 Pin 6 Amps Controlled By One Switch On Independent Board. , All As Per Item No 1 Above But One 3 Pin Socket Out Let 15/16 Amps With Three Nos Single Core Unsheathed Pvc Insulated Cable Multistranded Copper Conductor Of Size 2.5 Sq Mm For Phase, Neutral & Earth Continuity Conductor. , S&F Switch Piano Flush Button Single Pole One Way 5/6 Amp. , S&F Switch Socket Combination 2 In 1, 3 Pin, 6 And 16 annual periodical maintenance Flush Type Universal , S&F Switch Socket Combination 2 In 1, 6A Flush Type , S&F Socket Outlett 2 In 1, 3 Pin, 6A Flush Type , S&F Ceiling Rose Surface Bakelite 65Mmx50mm 100Watt Three Terminal. , S&F Sheet Metal Enclosure Double Door For Mcb Db Single Pole And Neutral 4 Way With 200 Amps Rated Bus Bar 240 Volts Double Door (Metallic) Type Including Taking Down Old Unserviceable Mcb Db With Mcbs. , M&L For Sub Main Wiring With Two Single Core Pvc Insulated Of Size 6 Sqmm Frls Unsheathed Copper Conductor 1100 Volt Grade Multistandard And Incl Drawn Through And Including Pvc Casing Caping Including 6.0 Sqmm Frls Copper Wire For Earth Continuity Wire And Connected Of Common Earth Dolly Including Taking Down Old Unserviceable Sub Main Wiring And Making Good Of Existing Surface. Note:- (I)One Run Of Pvc Casing Caping, Two Run Of 6 Sq Mm Copper Conductor & One Run Of 6.0 Sq Mm Copper Conductor Is Measured As One Unit. , S&F Sheet Metal Enclosure Double Door For Mcb Db Single Pole And Neutral 8 Way With 200 Amps Rated Bus Bar 240 Volts Double Door (Metallic) Type Including Taking Down Old Unserviceable Mcb Db With Mcbs. , S&F Mcb Spn 32 Amps 240 Volts C Series, 10 Ka, 50 Hz. Make:- Havells, Legrand, Indo Asian , S&F Mcb Sp 5 To 32 Amps 240 Volts C Series, 10 Ka, 50 Hz Including Connection In The Db And Testing/Commissioning. Make:- As Approved Make Of Db , Supply And Fixing Led Lights Fitting 1X 18W, 4 Feet, 220V,Ac Decorative Box Type With Driver, Holder Including Led Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete. , Supply And Fixing Led Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65/66 Protection Complete. , Supply And Laying Or Fixing Or Passing Through Pipe, 1100 Volts Grade Heavy Duty Cable With Pvc Insulated Aluminium Conductor Served With Aninner Sheathing Of Pvc Tape Armoured With Galvanised Steel Wire Or Tape And Overall Pvc Sheathed 6 Sq. Mm Nominal Cross Section In Service Connections , Supply And Fix Exhaust Fan Made Of Sturdy Engineering Plastic Complete With Louvers Shutter, Voltage 230V, 50 Hz, Rpm 1200, Copper Winding Of Sweep 300M Complite All A Specified And As Directed By Engineer-In-Charge. , Supply And Laying Or Fixing Or Passing Through Pipexlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade Of Size 10 Sqmm 2 Core Complete Including Taking Out Old Unserviceable Cable All As Specified And Directed By Engineer In Charge. , S&F Dwc Pipe 63/50Mm Size All As Specified And Directed By Engr-In-Charge. , M&L For Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation Of Poles, Etc. Or For Laying Of Cable, Pier Holes, Etc. Nexc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Soft And Loose Soil , M&L For Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Of Hard & Dense Soil , M&L For Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Of Any Type Of Soil , Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Buried Directly In Ground( Earth Pit Not Less Than 2.25 Meter Deep Below Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, Connected To Galvanised Earth Lead Wire 4.0Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel, All As Shown In Electrical Plate No 3 Of Ssr Pt I Including Necessary Excavation And Earth Work Plain Cement Concrete (1:3:6) Type C-1 With 50 Mm Thick Pre Cast Reinforced Cement Concrete ( 1:2:4) Type B-1 Cover Slab Framed With 50X30x4 Mm Ms Angle (Reinforced With 6 Mm Dia Deformed Bar @ 15 Cm C/C Both Ways And Suitable Handle Of 10 Mm Dia Round Bar) Including Providing Charcoal Or Coke And Magnesium Sulphate In Alternate Layers Of 15 Cm Compacted Thickness All Around The Earth Electrode, With Funnel And 20 Mm Bore Galvanized Iron Watering Pipe (Medium Grade) Wire Mesh, Copper Lugs, Complete In All Respect., Gi Earth Wire Protected By 40 Mm Bore (Light Grade) Galvanized Iron Pipe And Other End Connected To The Earth Bar (Test Point) Made Of Ms Flat (400X32x6 Mm) Bend In ‘D Shape And Fixed To Wall By Means Of Fast Nut Or Bolt Grouted In To Wall At 1 Mtr From Plinth Height. 4Sqmm Pvc Insulated (Colour Green) Copper Conductor Single Run As Earth Continuity Conductor Along With 15 Mm Pvc Conduit Grouted In Wall Or Fixed On Wall Surface To Be Continued Up To Main Switch Board And Fix With Common Earth Dolly As Directed By Eic . Disposal Of Soil To A Distance Not Exceeding 50 Mtr And Necessary Testing On Completion Complete Including Taking Out Old Unserviceable Earthing Materials All As Specified And As Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
25.
Educational and Research Institute #10967168 AOC
Equipment For Civil Lab Equipment For Civil Lab, Basic Civil Lab, Transport And Highway Lab, Advance Structural Lab , Equipment For Basic Civil Engineering Laboratory (Sheet 1) , Equipment For Advanced Structural Testing Laboratory(Sheet 2) , Equipment For Transportation & Highway Laboratory (Sheet 3) , Service(Sheet 4)-1 1 Concrete Mixer, Pan Type 2 Mould, Cast Iron, for 150mm Cube with ISI marked and NABL calibration Certificate 3 Beam Mould, 100mm x 100mm x 500mm 4 Beam Mould, 150mm x 150mm x 700mm 5 Cylindrical Mould, Cast Iron, Split Lengthwise 150 mm diameter x 300mm high 6 Mould, Steel, for 70.6mm cube with ISI Mark and NABL calibration Certificate 7 Tamping Rod 8 Vibrating Table 9 Slump Test Apparatus 10 Consistometer (Vee Bee Consistometer) 11 Flow Table, Motorized 12 Compaction Factor Apparatus 13 Concrete Penetrometer, Spring Type 14 Air Entrainment Meter Capacity 0.005m3 (5 liters) suitable for aggregate size up to 38mm 15 Curing Tank for 6/24moulds of 150mm/70.6mm size with NABL Calibration Certificates 16 Accelerated Curing Tank for 6 moulds of 150mm size with NABL Calibration Certificates 17 Capping Set, Vertical, for capping 150mm dia cylinders and cores 18 Concrete Permeability Apparatus 19 Compressor for Permeability Apparatus 20 Air Permeability Apparatus (Blaine type) 21 Vicat Apparatus 22 Le-Chatelier Mould 23 Le-Chatelier Water Bath with Controller 24 Le-Chatelier Flask 25 Shrinkage Bar Mould with NABL Calibration Certificate 26 Cement Autoclave 27 Length Comparator, Digital 28 Flow Table, Electric Operated 29 Automatic/Manual Digi Mortar Mixer Capacity 4.75litre 30 Vibration Machine, with built-in Digital Timer, NABL Calibrated 31 Gauging Trowel 32 Gauging Trowel 33 Sieves Set (Course) 34 Sieves Set (Fine) 35 Concrete test Hammer 36 Automatic Compression Testing Machine 37 Flexure Test Attachment 38 RCPT (4 CELL MODEL) 39 Drying Shrinkage 40 Carbonation Test Chamber 41 1000kN Beam Testing Set Up 42 Pycnometer 43 Pull off tester 44 Hot Air Oven 45 Sieve shaker (Motorized) 46 Sieve shaker (Motorized) 47 Electronic Weighing Balance with Legal Metrology Test Certificate 48 Electronic Weighing Balance with Legal Metrology Test Certificate. 49 Electronic Weighing Balance with Legal Metrology Test Certificate. 50 Electronic Weighing Balance with Legal Metrology Test Certificate. 51 Electronic Weighing Balance with Legal Metrology Test Certificate. 52 Impact of Jet on Vanes Apparatus 53 Orifice Meter Apparatus 54 Flow Over Notch Apparatus 55 Friction in Pipelines Apparatus 56 Venturimeter Apparatus 57 Orifice & Mouthpiece Apparatus Bernoullis Theorem Apparatus 59 Reynolds Apparatus60 Metacentric Height Apparatus 61 Study of Pipe Fittings, Sudden Enlargement & Contraction Apparatus 62 Force Vortex Apparatus 63 Pelton Wheel Turbine Test Rig 64 Francis Turbine Test Rig 65 Reciprocating Pump Test Rig 66 Standard Penetration Test (SPT) 67 `A Drill Rod, 1m long complete with adaptor 68 Dynamic Cone Penetration Test Apparatus (DCPT) 69 `A Drill Rod, 1m long complete with adaptor 70 Hand Operated Extractor 38mm mm dia specimen 71 Sampleject-5000, Hydraulic sample extruder, Electronic cum hand operated 72 Speedy Moisture Meter, Range 0-25% (Gauge Div.:0.5%) with digital weighing balance 73 Infra-Red Moisture Meter 74 Liquid Limit Device, motorised, with Casagrande grooving tools and gauge block 75 Liquid Limit Device, Hand Operated, with Casagrande grooving tools and gauge block. 76 Plastic Limit set comprising of glass plate, Brass rod, Spatula, Moisture Tin & Porcelain Dish. 77 Shrinkage Limit Set 78 Universal Penetrometer 79 Penetration Test Cone 80 Penetration Test Cup, 55 mm dia x 50 mm deep 81 Pycnometer 82 Andreasen Pipette Stand 83 High Speed Stirrer New Model 84 Hydrometer, Range: 0.995 to 1 Measuring specific gravity of liquid against buoyancy. Used for particle size analysis of fine grain soil less than 75-micron size 85 Plummet Balance 86 Unconfined Compression Tester for load measurement 87 Digital Direct Shear Test Apparatus, 2kN 88 Compaction Test Apparatus, Manual -Light Compaction made of Mild Steel 89 Compaction Test Apparatus, Manual-Heavy Compaction made of Mild Steel 90 Universal Automatic Compactor with Mild Steel compaction mould 91 Relative Density Apparatus 92 Soil Permeability Apparatus 93 Overhead Tank, made of steel, approx., 37.5cm dia x 1m high 94 Grooved M.S. Plate, 30cm x 30cm square x 25mm thicks + Plate bearing Apparatus with Load Truss of 500kN 95 (Plate Bearing Apparatus) 96 Core Cutter 97 Triaxial Shear Test Apparatus 98 Sand Replacement Method Apparatus 99 Van Shear apparatus 100 Electronic Three Gang Bench Type Consolidometer Front Loading 101 Hot Air Oven 102 Sieve shaker (Motorized) 103 Field CBR Test Apparatus with Proving Ring and Dial Gauge 104 BOD Incubator 105 Turbidity Meter 106 pH Meter 107 Conductivity meter 108 Portable UV Visible Spectrophotometer 109 Dissolved Oxygen meter 110 Portable COD meter 111 TSS analyser 112 TDS Analyzers 113 Particulate Matter Sampler 114 Hot Air Oven 115 Muffle Furnace 116 Digital Colony Counter 117 Water bath 118 Open Reflux COD Digester 119 Electronic Weighing Balance 120 Electronic Weighing Balance 121 Infrared thermometer 122 Microscope 123 Magnetic Stirrer with hot plate 124 Jar Test Apparatus Flocculator 125 Test tube 126 BOD Bottle 127 Porcelain dish 128 Measuring cylinder 129 Filter Paper 130 Burette 131 Burette stand with rod, clamp & boss head 132 Needle Vibrator 133 Vibratory hammer 134 Concrete specimen cutter 135 Curing Tank 136 Accelerated Curing Tank 137 Compressor with Nozzle 138 Deep Refrigerator 139 Refrigerator 1 Thickness Gauge 2 Length Gauge 3 Aggregate Impact Tester 4 Crushing Value Apparatus 5 Los Angeles Abrasion testing machine with counter 6 Density Basket 7 Buoyancy Balance 8 Universal Penetrometer 9 Penetration Cone 10 Bitumen Penetration Kit 11 Ring and Ball Apparatus 12 Thermometer IP 60C 13 Thermometer IP 61C 14 Thermometer IP 8C, Range 0°C to 45°C 15 Thermometer IP 9C, Range 40°C to 85°C 16 Thermometer IP 10C, Range 76°C to 122°C 17 Cannon Manning cum Cannon Fenske Viscometer bath with Vacuum Pump 18 Cannon Manning Vacuum Viscometer Tube, Size 6 19 Cannon Manning Vacuum Viscometer Tube, Size 7 20 Cannon Manning Vacuum Viscometer Tube, Size 12 21 Cannon Manning Vacuum Viscometer Tube, Size 13 22 Thin Film Oven/Loss on Heating Oven 23 Rolling Thin Film Oven 24 Flash Point (Closed) Pensky-Martens Apparatus 25 Thermometer IP 15C Range 5°C to +110°C 26 Thermometer IP 16C Range 90°C to +370°C 27 Flash Point (Open) and Fire Point, PenskyMartens Apparatus 28 Thermometer IP 15C Range 5°C to +110°C 29 Thermometer IP 16C Range 90°C to +370°C 30 Specific Gravity Bottle 31 Ductility Testing Machine with Digital Temperature Indicator 32 Centrifuge Extractor with NABL Calibration Certificate. 33 Marshall Apparatus, 50kN Single Speed 4 Diameter Sample 34 Pavement Core Drilling Machine 35 Diamond Core Bit 36 Asphalt Mixer, 5 L Capacity 37 Skid Resistance Tester 38 Asphalt Mixer Theoretical Density Meter 39 Modified Roughness Indicating Machine (MERLIN) 40 Bump Integrator with pre-set facility and CRRI calibration certificate 41 Pavement Dynamic Cone Penetrometer 42 Film Stripping Device 43 Saybolt Viscometer 44 Mastic Asphalt Tester 45 Serological Water Bath, Double Walled, with Digital Controller Cum Indicator and Stirring Arrangement 46 Brookfiled Viscometer 47 Thin Film Oven 48 Ignition Oven Asphalt Content Tester with IRC Accreditation. 49 Marshal Automatic Compactor 50 Roughometer (wireless) 51 Radar Gun 52 Helium Pycnometer 53 Laboratory Hot Plate 54 Sieve shaker (Motorized) 55 Sieve shaker (Motorized) 1 SCHMIDT Live N 2 Rebound Hammer Sensor Kit (For Rock) Ultrasonic Pulse Velocity 4 Profometer Rebar Detection & Cover Meter with 5 yrs. software subscription 5 Diamond Core Drilling Machine for Concrete 7 Structure Scan Mini LXT for Concrete Scanning 8 Pile Integrity Test 9 PIT-W Professional Software 10 Impact Echo 11 Light Weight Deflect meter 12 Falling Weight Deflectometer 13 Non-nuclear density gauge (for Soil) 14 Non-Nuclear Asphalt Density Gauge 15 Resistivity Meter (1-D) 16 Electrical Resistivity Imaging system & IP-System 17 Single channel & Multichannel Seismograph 18 Ground penetrating Radar (GPR) 19 Microtremor (Passive Seismic monitoring 20 Pneumatic Adhesion Tensile Strength Testing Instrument (PATTI 21 Electronic Weighing Balance with Legal Metrology Test Certificate. 22 Electronic Weighing Balance with Legal Metrology Test Certificate.
Contract Date: May 05, 2026 Contract Value : 7.71 Crore
Government Departments No of Bidders 1
26.
Heavy Industries and Public Enterprises #10902355 Technical Bid
D/G Eot Cranes Above 100T Refer Technical Specification For Complete Scope , D/G Eot Cranes Above 100T As Per Technical Specification No- Pe-Ts-Cb- 501-A501 , Total Lump Sum Firm Price For Engineering Part, Supply Part, Service Part (Supervision), Mandatory Spares, Healthiness Check Services Comprising Of Design (I.E. Preparation And Submission Of Drawing /Documents Including “As Built” Drawings And O&M Manuals), Engineering, Manufacture, Fabrication, Assembly, Inspection / Testing At Vendors & Sub-Vendor’S Works, Painting, Maintenance Tools & Tackles, Fill Of Lubricants & Consumables Along With All Accessories And Spares For Erection, Start Up And Commissioning, Slings For Load Testing Of Cranes & Lifting Beam, Forwarding, Proper Packing, Shipment And Delivery At Site, Supervision Of Unloading , Supervision Of Erection And Commissioning Including Load Testing Of Cranes & Lifting Beam, Healthiness Check Service Of Eot Cranes For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order Of. A) 2 Nos.265/25T Dg Eot Crane With Span, Lift And Baylength As Per Crane Clearance Diagram For 1X800 Mw Darlipali Stpp Project. (Refer Annexure-I & V For Project Wise Break Up Of Group-1) , Total Lump Sum Firm Price For Engineering Part, Supply Part, Service Part (Supervision), Mandatory Spares, Healthiness Check Services Comprising Of Design (I.E. Preparation And Submission Of Drawing /Documents Including “As Built” Drawings And O&M Manuals), Engineering, Manufacture, Fabrication, Assembly, Inspection / Testing At Vendors & Sub-Vendor’S Works, Painting, Maintenance Tools & Tackles, Fill Of Lubricants & Consumables Along With All Accessories And Spares For Erection, Start Up And Commissioning, Slings For Load Testing Of Cranes & Lifting Beam, Forwarding, Proper Packing, Shipment And Delivery At Site, Supervision Of Unloading , Supervision Of Erection And Commissioning Including Load Testing Of Cranes & Lifting Beam, Healthiness Check Service Of Eot Cranes For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order Of. A) 2 Nos. 200/20T Dg Eot Crane With Span, Lift And Baylength As Per Crane Clearance Diagram For 2X660 Mw Dvc Raghunathpur Project. B) 2 Nos. 200/25T Dg Eot Crane With Span, Lift And Baylength As Per Crane Clearance Diagram For 2X660 Mw Cspgcl Korba West Project. (Refer Annexure-Ii & V For Project Wise Break Up Of Group-2) , Total Lump Sum Firm Price For Engineering Part, Supply Part, Service Part (Supervision), Mandatory Spares, Healthiness Check Services Comprising Of Design (I.E. Preparation And Submission Of Drawing /Documents Including “As Built” Drawings And O&M Manuals), Engineering, Manufacture, Fabrication, Assembly, Inspection / Testing At Vendors & Sub-Vendor’S Works, Painting, Maintenance Tools & Tackles, Fill Of Lubricants & Consumables Along With All Accessories And Spares For Erection, Start Up And Commissioning, Slings For Load Testing Of Cranes, Forwarding, Proper Packing, Shipment And Delivery At Site, Supervision Of Unloading , Supervision Of Erection And Commissioning Including Load Testing Of Cranes, Healthiness Check Service Of Eot Cranes For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order Of. A) 2Nos. 140/30T Dg Eot Crane With Span, Lift And Baylength As Per Crane Clearance Diagram For 2X6600 Mw Mahagenco Koradi Project. (Refer Annexure-Iii & V For Project Wise Break Up Of Group-3) , Total Lump Sum Firm Price For Engineering Part, Supply Part, Service Part (Supervision), Mandatory Spares, Healthiness Check Services Comprising Of Design (I.E. Preparation And Submission Of Drawing /Documents Including “As Built” Drawings And O&M Manuals), Engineering, Manufacture, Fabrication, Assembly, Inspection / Testing At Vendors & Sub-Vendor’S Works, Painting, Maintenance Tools & Tackles, Fill Of Lubricants & Consumables Along With All Accessories And Spares For Erection, Start Up And Commissioning, Slings For Load Testing Of Cranes , Forwarding, Proper Packing, Shipment And Delivery At Site, Supervision Of Unloading , Supervision Of Erection And Commissioning Including Load Testing Of Cranes, Healthiness Check Service Of Eot Cranes For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order Of. A) 2 Nos. 160/40T Dg Eot Crane With Span, Lift And Baylength As Per Crane Clearance Diagram For 1X800 Mw Yamunanagar Project. (Refer Annexure-Iv & V For Project Wise Break Up Of Group-4)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 10
Uttar Pradesh View Result →
28.
Heavy Industries and Public Enterprises #10694482 Price Bid
Wheel Loader Supply And Commissioning Of One Number Wheel Loader For Its Alumina Refinery Plant At Damanjodi Odisha India , Supply Ofwheel Loader , Design, Engineering, Manufacture, Procurement Of Materials And Bought Out Components, Assembly At Shop,Inspection, Testing At Manufacturer Works And Supply Of 01 No. Wheel Loaderalong With All Accessories, First Fill Of All Lubricating Oil, Hydraulic & Transmission Oil, Commissioning Spares, Along With Safety Gadget, One Spare Wheel Assemblyand Standard Tools And Tackles As Per The Scope Of Supplyin Tender Document. , Charges For Pre – Dispatch Inspection By Nalco Representatives (For Inspection By Nalco Representatives, Inspector’S To & Fro Charges, Lodging, Boarding, Conveyance Etc Will Be Borne By Nalco) , Lump Sum Price Fortwo(2 Years ) Consumablesduring Warranty Period As Per Tender Documents , Lump Sumprice Fortwo(2Years ) O & M Spares Duringthe Warranty Period As Per Tender Documents , Optional Items(Offered Price Shall Remain Valid For A Period Ofof At Least 01 Year From The Bid Due Date) , Afss Or Automatic Fire Protection/Supresson System As Per Tender Documents , Provision Of Rear View Camera With Monitor For Viewing Rear Objects By The Opeartor As Per Tender Documents , Centralized Auto Lubrication System For Greasingvarious Points As Per Tender Documents , Services: Erection, Testing, Commissioning Atnalco Site , Lump Sum Charges For Erection, Testing, Commissioning At Site, Performance Gurantee Run Of The Wheel Loaderas Per Scope Of The Supply Mentionedin The Tender Documents , Indian Income Tax As Currently Applicable & Deductible At Source Based On Double Taxation Avoidance Agreement (Dtaa), If Any, On Foreign Supervision Cost (On Sl.No. 3.01) To Be Specified & Indicated Considering Necessary Tax Deduction At Source Certificate Will Be Furnished. N.B.: Indian Income Tax Has To Be Quoted By Foreign Bidder Only As Per The Annexure-Ix Of Nit. For Indian Vendors / Contractors, The Lump Sum Prices As At Sl.No. 3.01 Shall Be Inclusive Of Income Tax. Indian Bidder Not To Quote Against The Same And Please Enter “Zero”.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
29.
Heavy Industries and Public Enterprises #10694477 Price Bid
Tender For Articulated Boom Lift Working Height-41 Mtr. ( Min. ) For Smelter Plant At Nalco Angul, Odisha , Supply Of Articulated Boom Lift , Design, Engineering, Manufacture, Procurement Of Materials And Bought Out Components, Assembly At Shop, Inspection, Testing At Manufacturer Works And Supply Of 01 No. Articulated Boom Lift Along With All Accessories & Consumables, First Fill Of All Lubricating Oil, Hydraulic & Transmission Oil, Commissioning Spares, Along With Safety Gadget, One Spare Wheel Assemblyand Standard Tools And Tackles As Per The Scope Of Supplyin Tender Document. , Post Guarantee / Warrantee Annual Maintenance Contract ( Amc ) For 3 Years I.E., After Completion Of Guarantee / Warranty Period. , Lump Sum Charges For Post Guarantee / Warranty Amc For 3 Years As Per Scope Mentionedin The Tender Documents , Indian Income Tax As Currently Applicable & Deductible At Source Based On Double Taxation Avoidance Agreement ( Dtaa ) , If Any, On Foreign Supervision Cost ( On Sl.No. 3.01 ) To Be Specified & Indicated Considering Necessary Tax Deduction At Source Certificate Will Be Furnished. N.B.: Indian Income Tax Has To Be Quoted By Foreign Bidder Only As Per The Annexure-Ix Of Nit. For Indian Vendors / Contractors, The Lump Sum Prices As At Sl.No. 2.01 Shall Be Inclusive Of Income Tax. Indian Bidder Not To Quote Against The Same And Please Enter “Zero”. , Services: Installation, Testing, Commissioning, Training Atnalco Site , Lump Sum Charges For Installation, Testing, Commissioning, Training At Site As Per Scope Mentionedin The Tender Documents , Indian Income Tax As Currently Applicable & Deductible At Source Based On Double Taxation Avoidance Agreement ( Dtaa ) , If Any, On Foreign Supervision Cost ( On Sl.No. 3.01 ) To Be Specified & Indicated Considering Necessary Tax Deduction At Source Certificate Will Be Furnished. N.B.: Indian Income Tax Has To Be Quoted By Foreign Bidder Only As Per The Annexure-Ix Of Nit. For Indian Vendors / Contractors, The Lump Sum Prices As At Sl.No. 3.01 Shall Be Inclusive Of Income Tax. Indian Bidder Not To Quote Against The Same And Please Enter “Zero”.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
30.
Defence #10651593 Price Bid
Construction Of Permanent Infrastructures Including Development Work At Bop Balberia, Semharwa And Majhghgawan Of 50Th Bn Ssb Utraula ( Up ) ( Sh-Architect & Engineering Consultancy Services ) . 1 Carrying Out Topographical Survey And Providing Contour Map And Lay Out Plan Of Bop. Bop Balberia, Semharwa And Majhghgawan 2 Conducting Standard Penetration Test At The Site At An Interval Of 1.5 Meter As Per Is : 2131-1981 In 6 Dia Bore Hole Including Collection Of Disturbed Soil Samples At 1.5 Meter . Intervals And Undisturbed Soil Samples At 2.5 Meter Intervals And Their Complete Laboratory Testing As Per Indian Standard For Classification Of Soil And Determination Of Various Index And Engineering Properties Of Soil To Base The Allowable Bearing Capacity On Shear As Well As On Settlement Considerations Cost Of All Operations, Including Lab Charges, Labour, T&P, Transportation Of Equipment’S Upto Site Of Work And Back, Preparing And Submitting Test Report In 04 ( Four ) Copies In A-4 Size Paper Including Bearing Capacity For Buildings Etc All Complete As Per Direction Of Engineer-In-Charge. Bop Balberia, Semharwa And Majhghgawan 3 Providing Architectural Drawings Of Permanent Structures Of Bop Building Including Boundary Wall, Services Etc As Per Direction / Consultation With Engineer-In-Charge Of The Works ( 04 Copies ) . Bop Balberia, Semharwa And Majhghgawan 4 Providing Structural Design And Working Drawings Of All Components Of Bop Building Including Boundary Wall Etc As Per Direction / Consultation With Engineer-In-Charge ( 04 Copies ) .Bop Balberia, Semharwa And Majhghgawan 5 Preparation Of Detailed Estimate And Abstract Of Cost On The Basis Of Latest Delhi Schedule Rate Civil, Electrical & Horticulture And Analysed Item From Market For Construction Of Modern Building Design.Bop Balberia, Semharwa And Majhghgawan
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Uttar Pradesh View Result →
31.
Petroleum and Natural Gas #10607149 Price Bid
supply of Dry Chemical Haandling System , Design , Engineering , Supply , Shop Testing , Inspection ( Including 3Rd Party ) , Supervision Of Erection/Construction & Installation , Testing At Site , Commissioning Of Dry Chemical Handling System Inlcuding 1 Year Mandatory Spares For Normal Operation , Special Tools ( If Any ) , Mandatory Services ( If Any ) As Per Technical Specification No . S-17047-4-Bsm-Mr025 , Design , Engineering , Supply , Shop Testing , Inspection ( Including 3Rd Party ) , Testing At Site , Commissioning Of Dry Chemical Handling System As Per Technical Specification No . S-17047-4-Bsm-Mr025 , Commissioning Spares And Mandatory Spares For 1 Year Of Normal Operation , Special Tools ( If Any ) As Per Technical Specification No . S-17047-4-Bsm-Mr025 For Sr . # 1 . 01 Above . , Supervision Of Erection , Supervision Of Commissioning And Offering Successful Pgtr For The Offered Scope At Site As Per Mr No . S-17047-4-Bsm-Mr025 For Item Mentioned In 1 . 00 Above . ( Per Diem Charges For Up To 8 Hours On Normal Days As Applicable To Site ) , Supervision Of Erection , Supervision Of Commissioning And Offering Successful Pgtr For The Offered Scope At Site As Per Mr No . S-17047-4-Bsm-Mr025 For Item Mentioned In 1 . 00 Above . ( Per Diem Charges For Up To 8 Hours On Weekly Off Days/Holidays As Applicable To Site ) , Overtime Rate/ Hour Beyond Normal 8 Hours Work On Normal Working Days . , Overtime Rate/Hour For Work On Weekly Off Days/ Holidays ( As Applicable At Project Site ) . , Customer Training As Per Mr No . S-17047-4-Bsm-Mr025 For Item Mentioned In 1 . 00 Above . ( Per Diem Charges For Up To 8 Hours On Normal Days As Applicable To Site ) , Hazop Participation As Per Mr No . S-17047-4-Bsm-Mr025 For Item Mentioned In 1 . 00 Above . ( Per Diem Charges For Up To 8 Hours On Normal Days As Applicable To Site )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
32.
Educational and Research Institute #10583379 Price Bid
Tender For Electrical Renovation Work Of Ems Chair Library Hall- 1 1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A 2 1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B 3 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 4 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 5 1.14.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 6 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 7 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 8 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 9 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 10 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 11 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 12 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 13 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 14 1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 15 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 16 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 17 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 18 2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 19 1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 20 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 21 2.11 : Supplying and fixing single pole blanking plate inthe existing MCB DB complete etc. as required. 22 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 23 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 24 7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved asrequired. 25 5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 26 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 27 90.11.1.15 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) -double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) 28 90.12.5.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm 29 90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 30 90.12.9.2 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size 31 od41511/2024_2025 : Supplying and fixing 22 to 25 W LED (PF >0.96 ,Harmonics 9%) recess mounted round shaped down lighter suitable for low ceiling heights, ceiling should be cut inrequired shape and make good connection etc complete. 32 90.6.4.51 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 1 Run 33 od39724/2024_2025 : Supply, Installation ,Testing and commissioning of 400 mm AC Sweep oscillating type wall mounting fan with suitable clamp and bolt. 34 od39725/2024_2025 : Providing and fixing 10 SWG copper wire on surface or in recess for loop earthing
as required 35 od39726/2024_2025 : Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and
providing masonry enclosure with cover plate having locking arrangement and
watering pipe etc. with charcoal/coke and salt as required
(Dimension of pit shouldbe minimum of 2.5m*0.6m*0.6m) 36 od39731/2024_2025 : Dismantling the existing service connection from the LT post with out causing any damages and installation of new/existing WP wire including supporting wire. Dismantled materials shall be returned to the electrical store, Engineering department without causing any damages. 37 od39732/2024_2025 : Wiring plug point along with wiring of light point including supply fixing 5A flush type modular switch and 3 pin plug socket in combined position.(Combined Plug)

38 od41795/2024_2025 : Supply and laying 16/0.20 mm 3 core round copper conductor flex wire 39 od39735/2024_2025 : Dismantling the Fluorescent / Led lightfixture from the wall/ ceiling and conveying dismantled materials to electrical store with out any damage. etc completed. 40 od39737/2024_2025 : Dismantling thesingle phase LDB in the wall and old switch boards .Dismantled material return to the electrical store. 41 od40176/2024_2025 : Supply and Laying One number DWC/HDPE pipe in hard soil 0.60/0.75m below the ground level including excavation, Interlock removing 50/38 mm or nearest size and refilling the trench including interlock fixing, making good the same. 42 od40177/2024_2025 : Replacing 1 phase meter board to 3 phase meter board having 3 nos kitkat fuse (63 A) ,4P MCCB enclosure , neutral link etc 43 od40178/2024_2025 : supplying and laying Heat shrink sleeves in the unarmoured part of the AUG cable 44 od40179/2024_2025 : Supply and making outdoor end termination with heat shrinkable kit complete with all accessories including lugs suitable for size of 4core x 16 sq mm XLPE aluminium conductor cable at complete. 45 od40180/2024_2025 : Supplying and installing 3Nos. of 100A Kit Kat Fuse unit (Lug type)using suitable size metal box , clamps, bolts ,nuts neutral link etc complete on existing LT post and making end termination of suitable UG cable with aluminium lings on fuse side and winding on OH line.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
34.
Power #10564520 Price Bid
Development Of Distribution Infrastructure Of Packageprayagraj 1 At Prayagraj District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Cable For Consumer Service Connection With Accessories As Per Technical Specifications, Scope Of Works And Approved Drawings 3 Supply Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 4 Supply Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 5 Supply Of 10 Swg Gi Wire 6 Supply Of 8 Swg Gi Wire 7 Supply Of Gi Pipe / M.S Angle Along With Nails / Clamps / Proper Binding E.T.C. As Per Rec Std. 8 Conversion Of Existing Lt Lines On Bare Conductor To Areal Bunch Xlpe Cable 9 Conversion Of Existing Lt Lines With Bare Conductor To Ab Xlpe Cable Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 10 Supply Of 8.5 M / 180 Kgs Pcc Poles ( Pcc Pole As Per State Practice ) 11 Galvanized Stay Set For Lt Line With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, 1 No. Stay Guy Insulator, Nut Bolts, 1 No. Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 12 Conversion Of Existing Lt Lines Using New Earthing As Per Approved Drawings, Technical Specifications And Scope Of Work 13 Supply Of Spike Earthing Made Of 20Mm X 2500 Mm Gi Solid Rod 14 Supply Of 8 Swg Gi Wire For Earthing And Guarding 15 Supply Of Following Lt Ab Xlpe Cable For Conversion Of Existing Lt Bare Conductor Line With Ab Xlpe Cable As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 16 Supply Of Aerial Bunchedxlpe Cable 3 X 50 Sqmm+1X35 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 17 Supply Of Aerial Bunchedxlpe Cable 3 X 70 Sqmm.+1X50 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 18 Supply Of Aerial Bunchedxlpe Cable 3 X 95 Sqmm.+1X70 Sqmm. ( Bare Messenger Wire ) + 1X16 Sqmm. 19 Supply Of Aerial Bunchedxlpe Cable 3 X 120 Sqmm. + 1X95 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 20 Supply Of Pole Mounted Lt Distribution Box As Per Approved Drawings, Technical Specifications And Scope Of Work 21 Supply Of Three Phase Smc Distribution Box With Clamps 22 Supply Of Single Phase Smc Distribution Box With Clamps 23 Supply Of Xlpe Insulated Al. Cable For Energisation Of Distribution Box / Kiosk As Per Approved Drawings, Technical Specifications And Scope Of Work 24 Suppply Of 2Cx25 Sqmm Stranded Unarmoured Cable ( Al Conductor ) For Chargingsingle Phase Db 25 Suppply Of 4Cx35sqmm Stranded Unarmoured Cable ( Al Conductor ) For Chargingthreephase Db 26 Supply Of Stone Pad ( 300X300x75 ) 27 Supply Of Accessories For Ab Xlpe Cable As Per Approved Drawings, Technical Specifications And Scope Of Work 28 Stainless Steel Strap 29 Hdg Lt Pole Clamp With Nut & Bolt For Laying Abc 30 Dead End Clamp With I-Hook ( Insulated ) 31 Suspension Clamp With I-Hook ( Insulated ) 32 95 / 35 Sqmm - 70 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 33 120 / 50 Sqmm - 95 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 34 Lt Insulation Piercing Connector 120-50 Sqmm - 50-25 Sqmm Size ( For Energizing Distribution Box ) 35 Lt Insulation Piercing Connector 120-50 Sqmm - 120-50 Sqmm Size ( For Line To Line Jumpering ) 36 Lt Insulation Piercing Connector 16 - 25Sqmmsize Suitable For Street Light Connection 37 Pre-Insulated Compression Connectors Size 16 Sqmm Suitable For Ab Xlpe Cable 38 Pre-Insulated Compression Connectors Size 50 Sqmm Suitable For Ab Xlpe Cable 39 Pre-Insulated Compression Connectors Size 70 Sqmm Suitable For Ab Xlpe Cable 40 Pre-Insulated Compression Connectors Size 95 Sqmm Suitable For Ab Xlpe Cable 41 Pre-Insulated Compression Connectors Size 120 Sqmm Suitable For Ab Xlpe Cable 42 Heat Shrinkable Type End Cap For Ab Xlpe Cable 43 Supply Of New 11 Kv Lines : Feeder Segregation ( Agriculture Feeder ) 44 Supply Of Support For 11 Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work 45 Supply Of 8.5M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 46 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 47 Supply For 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Transformer Base Channel, Ms Flats Pole Extension Channel With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 48 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 49 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 50 Supply Of 11 Kv Danger Board 51 Supply Of Stone Pad 300X300x75 52 Supply Of Barbed Gi Wire 12 Swg 53 Supply Of Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, Stay Guy Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 1 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 54 Supply Of Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work. 55 Supply Of 11 Kv45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 56 Supply Of 11 Kv 5 Kn Polymer With Pin Insulators 57 Supply Of Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 58 Supply Of Spike Earthing 20Mm X 2500 Mm Gi Solidrod 59 Supply Of 8 Swg Gi Wire For Earthing And Guarding 60 Supply Of 6 Swg Gi Wire For Earthing And Guarding 61 Supply Of Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work 62 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 63 Supply Of 11 Kv, 600A, 3-Ph, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 64 Supply Of 11 Kv Lineunderground Railway Crossing Ensuring Statutory Clearances As Required As Per Technical Specification, Approved Drawings And Scope Of Work 65 Supply For 11 Kv Lineunder Ground Railway Crossing With 2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) Using 150Mm Dia Gi Pipes ( Grade A For Underground Laying And Grade B For Pole Support ) , Outdoor Heat Shrinkable Cable Jointing Kit, 11 Kv Lightening Arrestor Station Class 10Ka ( 6 Nos. ) , Lugs, 4 Nos Gi 3-Meters Long Pipe Earthing, 6 Swg Gi Wires, Cable Markers, Bi Metallick Clamps And Jumpering Etc As Required As Per Technical Specifications, Drawings And Scope Of The Work. 66 Supply Of 11 Lv Line Underground Highway Crossing Ensuring Statutory Clearancesas Required As Per Technical Specification, Approved Drawings And Scope Of Work 67 Supply Of 11 Kv Lineforunder Ground Highway Crossing By 2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) Using 160 Mm Hdpe Pipe At Road Crossing And 150Mm Dia Gi Pipes ( Gradeb For Pole Support ) , Outdoor Heat Shrinkable Cable Jointing Kits, 11 Kv Lightening Arrestor Station Class 10Ka ( 6 Nos. ) , Lugs, 4 Nos Gi 3-Meters Long Pipe Earthing, 6 Swg Gi Wires, 7 / 20 Gi Wire, Cable Markers, Bi Metallick Clamps And Jumpering Etc As Required As Per Technical Specifications, Drawings And Scope Of The Work. 68 Supply Of 12 Kv 3Ph Indoor Type Switch Gear And 11 Kv Xlpe Cable As Per Technical Specifications, Approved Drawings And Scope Of Works: 69 Supply Of Indoor Type 12 Kv 3 Ph 1250 A Vcb With Control And Protection System For Out Going Feeder Consisting Ofct, A-Meter, Volt-Meter, Relays, Energy Meter ( Tvm ) Dlms Compliant & Accessories Complete As Per Specifications For Feeder Breaker 70 11 Kv 3X 185 Sqmm Xlpe Armored Power Cable, Aluminum Stranded Conductor, Including Their Termination Materials Like Indoor And Outdoor Termination Kit, Glands, Lugs, Tagging, Cable Path Marker Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. 71 Supply For Augmentation Of Lines 72 Supply For Augmentation Of 33 Kv Line 73 Supply For Augmentation Of 3 Phase 33 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 74 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 75 Supply New Pre-Fabricated Hot Dip Galvanized Steel Item, For Augmentation Of 33 Kv Line, Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle ( 65X65x6mm ) , Ms Flats ( 65X8mm ) Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 76 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 77 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 78 Supply Of 33 Kv Danger Board 79 Supply Of Gi Barbed Wire 12 Swg 80 Supply For Augmentation Of 3 Phase 33 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material, Aluminum Tape And Helical Preformed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 81 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 82 Supply Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 83 Supply Of 33 Kv Under Ground Cable As Per Technical Specification, Approved Drawings And Scope Of Work. 84 Supply Of 3Cx300 Sqmm 33 Kv Xlpe Armored Cable 85 Supply Of 33 Kv3cx300 Sqmm Xlpe Armored Cable ( 2 Nos Including One Spare ) Accessories Like 160Mm Dia Hdpe Pipes For Road Crossing And 150 Mm Dia Gi Pipegrade B For Pole Support Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cablepath Markers, Bi Metallic Clamps, 7 / 20 Gi Wire As Per Technical Specification, Approved Drawing And Scope Of Work 86 Supplyof New Insulator And Hardware For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work 87 Supply Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 88 Supply Of 33 Kv 10 Kn Polymer Pin Insulators 89 Supply Of New Earthing Arrangement For Augmentation Of33 Kv Line As Per Technical Specifications, Approved Drawings And Scope Of Work. 90 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 91 Supply Of New Stay Set ( Galvanized ) For 33 Kv Line With 50X8 Mm Stay Clamp, 2 Nos. Guy Insulator, Anchor Plate ( 300X300x8mm ) , Nut Bolts, 1 No. Turn-Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 92 Supply Of New Gi Wire For Earthing And Guarding For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work. 93 Supply Of 6 Swg Gi Wire 94 Supply Of 8 Swg Gi Wire 95 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 96 Supply Of Pg Clamp For Dog To Dog Conductor 97 Supply Of Pg Clamp For Panther To Panther Conductor 98 Supply For Augmentation Of 11 Kv Lines 99 Supply For Augmentation Of 3 Phase 11 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 100 Supply Of 8.5 Meter Long / 180 Kg Pcc Poles ( Pcc Pole As Per State Practice ) 101 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Flats Pole Extension Canal With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 102 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 103 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 104 Supply Of 11 Kv Danger Board 105 Stone Pad ( 300X300x75mm ) 106 Supply Of Gi Barbed Wire 12 Swg 107 Supply For Augmentation Of 3 Phase 11 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material And Helicon Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 108 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 109 Supply Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 110 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 111 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 112 Supply Of 11 Kv 45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 113 Supply Of 11 Kv 5 Kn Polymer Pin Insulators 114 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 115 Supply Of Gi Earthing Spike Made Of 20X2500mmsolid Rod 116 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, 1 No. Guy Insulator, Anchor Plate ( 200X200x6mm ) , Nut Bolts, 1No. Turn-Buckles, 1.8 M Long 16 Mm Diameter Solid Gi Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 117 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 118 Supply Of 6 Swg Gi Wire 119 Supply Of 8 Swg Gi Wire 120 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 121 Supply Of Pg Clamp For Weasel To Weasel Conductor 122 Supply Of Pg Clamp For Dog To Dog Conductor 123 Supply Of Pg Clamp For Rabbit To Rabbit Conductor 124 Installation Of Dt Capacitor 125 Supply Of Dt Capacitor With Fitting As Per Technical Specification, Approved Drawing And Scope Of Work 126 Supply Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 127 Supply Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 128 Supply Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 129 Supply Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 130 Supply Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 131 Supply Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 132 Erection Part 133 Installation Of Consumer Service Cable 134 Installation Of Armored Consumer Service Cable With Accessories Including Dismantling Of Existing Service Cable As Per Technical Specifications, Scope Of Works And Approved Drawings 135 Installation Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 136 Installation Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 137 Gi Wire 8 Swg 138 Gi Wire 10 Swg 139 Installation Of Gi Pipe / M.S Angle Along With Nails / Clamps / Proper Binding E.T.C. As Per R.E.C Std. 140 Erection For Conversion Of Existing Lt Lines On Bare Conductor To Aerial Bunch Xlpe Cable 141 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil Of Following Pole As Per Scope Of Work, Approved Drawings And Specifications: 142 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 143 Erection Of Following Types Of Poles For Lt Overhead Line With Stone Pad, Pole Numbering By Paint With Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 144 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Stone Pad As Required - ( State Practices Of Pcc Pole And Stone Pad To Be Used ) 145 Excavation Of Lt Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 146 Normal Soil 147 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 1 No. ) And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 148 Removal Of Existing Lt Bare Line Conductor & Fixtures, Depositing To Stores Of Employer And Erection, Testing & Commissioning Of New Areal Bunched Xlpe Cable, Fixing Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, Pre- Insulated Compression Connectors, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Stainless Steel Strap, Single And Three Phase Pole Mounted Distribution Board, Energisation Of Distribution Box Through 2Cx25 Sqmm And 4Cx35 Sq.Mm Xlpe Cable Fixing End Cap Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 149 Erection Of Aerial Bunched Xlpe Cable3 X 50 Sqmm +1X35 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 150 Erection Of Aerial Bunched Xlpe Cable 3 X 70 Sqmm +1X50 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 151 Erection Of Aerial Bunched Xlpe Cable 3 X 95 Sqmm +1X70 Sqmm ( Bare Messenger Cum Neutral ) + 1X16 Sqmm 152 Erection Of Aerial Bunched Xlpe Cable 3 X 120 Sqmm+ 1X95 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 153 Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications 154 Erection Of 8 Swg Gi Wire For Earthing By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc As Per Approved Drawings, Scope Of Work And Technical Specifications 155 Erection, Testing And Commissioning Of New 11 Kv Lines: Feeder Segregation ( Agriculture Feeder ) 156 Survey, Route Alignment & Pole Spotting, Preparation Of Survey Report And Uploading In The Web Portal After Approval Of Project Manager 157 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil For Following Type Pole As Per Scope Of Work, Approved Drawings And Specifications: 158 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 159 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 160 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Painting With Red Oxide & Aluminum Paint To Stp Poles Including Paint, Numberingof Poleby Paint Including Cement Concrete Foundation Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 161 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Pad Including Cement Concreting, ( State Practices Of Pcc Pole, Stone To Be Used ) 162 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.5 Cmt + 0.014 Cmt ( Muffing ) 163 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washersas Per Technical Specification, Approved Drawings And Scope Of Work. 164 Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 165 Erection, Testing & Commissioning Of Spike Earthing 20Mm X 2500Mm Gi Solid Rod 166 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 167 Normal Soil 168 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 169 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 170 Erection Of 5 Kn 11 Kv Polymer With Pin Insulator 171 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 172 Laying Out, Tensioning, Binding Of Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 173 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 174 Erection, Testing And Commissioning Of Vertical Type 11 Kvab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 175 Erection, Testing & Commissioning Of 11 Kv Line For Under Ground Railway Crossing By2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) , Using 150Mm Dia Gi Pipes, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, 4 Nosgi 3-Meters Long Earthing Pipe, 6 Swg Gi Wires, Cable Markers, Clamps, Jumpering And 11 Kv Station Type Lightening Arrestors ( 6 Nos. ) , Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 176 Erection, Testing & Commissioning Of 11 Kv Line For Under Ground Highway Crossing By2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) , Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, 4 Nosgi 3-Meters Long Earthing Pipe, 6 Swg Gi Wires, 7 / 20 Gi Wire, Cable Markers, Clamps, Jumpering, 11 Kv Station Type Lightening Arrestors ( 6 Nos. ) , Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 177 Erection Of 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breaker With Adopter Panel For Out Going Feeder By Leveling, Alignment And Welding On Existing Cable Trench In Control Room. Testing & Commissioning Of Indoor Vcb Panel Including 3 Nos Indoor Type Current Transformer, A-Meter, Volt-Meter, Relay & Accessories Protection As Per Approved Drawings, Technical Specifications And Scope Of The Work.: 178 Providing And Fixing Of Sign Board Includingmaterial And Its Fabrication , Painting , Writing , Logo And Scheme Etc As Per Rdss Guidelines And T.S 179 Laying, Erection, Termination Using Indoor & Outdoor Termination Kit, 11Kv 3X 185 Sqmm Xlpearmored Power Cablesas Per Technical Specifications, Approved Drawings And Scope Of Works. : 180 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 181 Erection Of 6 Swg Gi Wire 182 Erection Of 8 Swg Gi Wire 183 Extension Of Control Room Of 33 / 11 Kv Substation To Accommodate Vcb For New 11 Kv Feeders As Per Technical Specification, Approved Drawing And Scope Of Work. 184 Design, Engineering Construction Of Control Room Building Extension 300 Sq Feet Including Cost Ofall Materials, T&P And Labour, Etc. As Per Technical Specification And Approved Drawing As Per Direction Of Employer 185 Shifting Of Following Distribution Transformer Along With Fixture Including Dismantling , Shifting And Erection From One Location To Another Location As Per Approved Survey. 186 Single Phase Transformer 187 Three Phase Transformer 188 Erection For Augmentation Of Lines 189 Erection For Augmentation Of 33 Kv Line 190 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 191 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 192 Erection Of Following Types Of Additional Poles Matching With Existing Line Supports By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Painting With Red Oxide & Aluminum Paint Including Paint, Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 193 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.5 Cmt + 0.014 Cmt ( Muffing ) 194 Excavation Of Stay Pit For 33 Kv Stay In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 195 Normal Soil 196 Erection Of Complete Stay Set With Gi Stay Wire ( 7X4.00 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.3 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 197 Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 198 Erection Of 33 Kv 10 Kn Pin Insulator With Gi Pin 199 Erection Of 33 Kv 70 Kn Disc Insulator With Strain Hardware ( Set Of 3, 11 Kv Disc Insulators ) 200 Erection, Testing & Commissioning Of New Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 201 Dismantling Of Existing Overhead Line Conductor And Fittings, Depositing The Dismantled Material To EmployerS Store And Laying Out & Stringing Of New Acsr Conductor Of Following Sizes By Providing Jointing Sleeves, Binding Wire & Tape & Helical Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 202 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 203 Stringing Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 204 Erection, Testing & Commissioning Of 33 Kvunder Ground Cable By2 Nos ( Including One Spare ) 3Cx300 Sqmm Xlpe Armored Cable, Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cable Markers, Clamps, Jumpering, 7 / 20 Gi Wire Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 205 Erection For Augmentation Of 3 Phase 33 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 206 Erection Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 207 Erection Of 33 Kv 10 Kn Polymer Pin Insulators 208 Erection, Testing & Commissioning Of Earthing As Per Technical Specifications, Approved Drawings And Scope Of Work. 209 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 210 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 211 Erection Of 6 Swg Gi Wire 212 Erection Of 8 Swg Gi Wire 213 Erection For Augmentation Of 11 Kv Lines 214 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 215 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 216 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 217 Erection Of 8.5 M / 180 Kgs Pcc Poles Withbase Stone Pad ( State Practices Of Pcc Pole And Base Plate / Stone To Be Used ) 218 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 219 Normal Soil 220 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 221 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 222 Erection Of 11 Kv Pin Insulator With Gi Pin 223 Erection Of 11 Kv Disc Insulator With Strain Hardware 224 Dismantling Of Existing Overhead Line Conductor & Fittings And Depositing To EmployerS Store, Laying Out, Tensioning, Binding Of New Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 225 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 226 Stringing Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 227 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 228 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Channel, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Hdg Ms Nuts, Bolts & Washers As Per Technical Specification, Approved Drawings And Scope Of Work. 229 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 230 Erection Of 5 Kn 11 Kv Polymer Pin Insulator 231 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 232 Earthingand Guarding Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 233 Erection, Testing & Commissioning Of Spike Earthing 20Mm Solid Rod 234 Erection Of 8 Swg Gi Wire For Earthing And Guarding 235 Erection Of 6 Swg Gi Wire For Earthing And Guarding 236 Erection Of Dt Capacitor 237 Erection, Testing & Commissioning Offollowing 440 Volt Lt Shunt Capacitor Including Mounting Structure And Accessories As Required As Per Technical Specifications, Approved Drawings And Scope Of Work. 238 Erection Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 239 Erection Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 240 Erection Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 241 Erection Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 242 Erection Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 243 Erection Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 244 Discount Offered In % 245 Words Final Quoted Price After Discount
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttar Pradesh View Result →
35.
Health and Family Welfare #10551414 Price Bid
Tender For Electrification Work In Phc Building At Palasani District Jodhpur - Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
36.
Health and Family Welfare #10551411 Price Bid
Tender For Electrification Work In Phc Building At Rajlani District Jodhpur - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
37.
Health and Family Welfare #10551406 Price Bid
Tender For Remaining Electrical Work Phc Building At Sadri District Jodhpur - 1 (Integrated Elect. BSR 2021) Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,18SWGHotDippedGalvanized ModularBox withearth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pinceilingrose/lampHolder/3pinconnector,screwsetc, making connections,all as per pre approved by Engineer in charge, testingetc.completeasrequired. Forspecificationofcopper Conductor,Phenolic Laminated sheets & Electrical/ Wiring accessories referChapterE-04,E-05&E -07 .For additional technicalparametersofproducts/ work, refer Annexure A attached with this BSR. 2 Medium point (up to 6 mtr.) 3 Long point(up to 10 mtr..) 4 WiringoftwincontrollightpointasperPWDspecificationfor electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulatedunsheathedflexiblecopperconductor 1.1kVgrade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,2 nos. 18 SWG Hot Dipped Galvanized Modular Box with earth terminal ,2Nos6AtwowayModularswitch,3pinceilingrose/lamp holder/ 3pinconnector,Modularfaceplatewith gridplate, screws etc,all as per pre approved by Engineer in charge,making connections,testingetc. completeasrequired. Forspecification ofcopper Conductor, PhenolicLaminated sheets&Electrical/ Wiringaccessories referChapterE-04,E-05&E-07. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Medium point (up to 6 mtr.) 5 Long point(up to 10 mtr..) 6 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification forelectricalWorkswithISI marked1.5 sq.mmnominalsizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit&itsallaccessories(J.B.,Bendsetc.),roundtiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modularswitch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, makingconnections,testingetc.completeasrequired. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07.For additional technical parameters of products/ work refer Annexure A attached with this BSR . On board 7 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1 x 1.5 sq.mm 8 3x 1.5 sq.mm 9 2 x 2.5 sq. mm. + 1x1.5sqmm 10 1 x 4.0 sq.mm 11 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 12 1 x 6.0 sq.mm 13 4 x 6.0 sq.mm 14 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 16.0 sq.mm 17 S&Ffollowingsizes(dia.)ofISImarkedMMS(IS:9537P-III) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptancetests reports byanyNABLaccreditedlabfortheconduitshallbesubmitted before execution & All as per pre approved by Engineer in charge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR . MMS ( IS:9537 P - III ) PVC conduit 18 25 mm 19 32 mm 20 Supplying andLaying ISImarkedP.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type Aor C,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6.0 Sq.mm 3 core flat / Round 21 Providing & Fixing of phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 75 mm dia 22 P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single pole MCB6 A to 32 A rating 24 Double pole MCB 40 A rating 25 Four pole MCB 50-63 A rating 26 Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . IP-43 Double door (single phase) 27 16 Way (16 O/G +2 I/C) 28 IP-43 Double door (Three phase) 6 Way ( 18 O/G + 8 I/C ) 29 Providing & Fixing of metal clad industrial plug top & socket unit with pin and sleeve type copper contact on porcelain/ bakelite base insheet steel( CRCA ) powed coated enclosure as per PWD specification for electrical Works conforming to Is 8623 & IEC 61439-3 (without MCB) including , all as per pre approved by Engineer in charge,making connections,, testing etc.as required .OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 A Double Pole(single phase Three pin ) 30 Providing & Fixing of recessed/surface mounting heavy duty sheet steel not less then 1.2 mm thick End Box as per PWD specification for electrical Works for distribution board duly phophatised powder coated complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . For TPN 6 way DB 31 Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling roses as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Providing & Fixing of ISI marked (IS:2268-1994) gong bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 33 Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 5 step fan regulator 100 watt 2 Module 34 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35 SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure (b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 36 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 37 Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type 38 Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field- programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type Confirming to IEC 62053-21 Below 500 A 39 Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Red/yellow/Green colour 40 Blue / white Colour 41 Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA 42 Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range - 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 43 Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV 44 SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 45 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 46 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Open execution type 160 A 47 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 %& as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Armoured Cable 6.0 Sq. mm 2 core 48 10.0 Sq. mm 2 core 49 35.0 Sq. mm 4 core 50 Providing & laying of Double wall corrugated pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required( Excavation of Earth to be paid Extra as required. ) of following Outer Dia. / Inner dia as per IS:4984:1995. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 110 / 95 mm 51 SITC of chemical Gel earthing system of Dual Pipe Technology made of with B Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second. (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts. (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell GI pipe 2000 mm long, 80 / 50 mm, Terminal 50mm x 6 mm GI Strip 52 Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 25mm x 3mm Alum. Strip 53 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 100 mm dia. 54 Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start,aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to al lthe performance requirements laid down in IS 374:2019 inluding all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 55 Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR300 mm sweep(900/1400 RPM) 56 Making of hole in wall (brick/stone) of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: Up to 457 mm size 57 P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Up to 380 mm size 58 Providing & Fixing of ISO Certified company made ISI marked (IS:2082) of 5 star rated vertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloy connection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 15 Ltr. 59 25 Ltr. 60 SITC of ISO Certified company made MNRE approved & confirming to IS:12933 P-1,2,3 & 5 Flat Plate Collector type solar hot water system with collector, insulated stainless steel (SS grade:304) storage tank with electrical back up with Portable Residual Current Device ( PRCD ) facility form OEM , CRCA Powder coated /MS stand for Collector & Tank etc. as required. of following capacity complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 100 litre/ day 61 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 4 LED Tube shape fixture 1 X 18/20 W 62 Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. Surface Mounting LED Downlight 18/20W 63 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attached with this BSR. Suspended Mounting/Surface Mounting 36W LED light fixture 2x2 with acrylic / prismatic front cover. 64 Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stabilization report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumenmaintained,colorRendering Index>70 andCCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . LED Street Light fixture 70 Watt 65 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fasteners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 66 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest amendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, separated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 67 Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessary connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, Un-sheilded Information Outlet 68 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single Aperture 69 Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 U wall mounted Enclosure 70 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 12 Ports 71 Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play easy setup with no configuration or no software needed, following Port fast ethernet - 8 10/100/1000 MBPS gigabit auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 24 Port 72 Supply Installationtesting&CommissioningofISOcertified manufacturer made Monoblock motor pump set ISI marked (IS:9079- 2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2- 1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, . Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 73 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 74 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest amendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord 1 Mtr 75 2 Mtr 76 Supply , Installation, Testing and Commissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. NABL accelerated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Non Invertor Type 1.5 TR with 3 star rating of BEE (ISEER not less then 3.5 ) 77 Providing & Fixing of ISI marked (IS : 15778 - 2007) Rigid CPVC drain water piping 6 kg/ cm2 with fittings like elbow, soket, Tee etc & support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 mm dia 78 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect. NABL accelerated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kVA 79 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accommodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 50 mm dia per running inch length 80 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 81 Supply , Installation, Testing and Commissioning of ISO certified company made self contained drinking water coolar with BEE Rated energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank , stainless steel water tray, minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 82 Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kg 83 Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35mm x 35mm x 5mm 84 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 A one way switch 85 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR6 A3/5 pin shuttered socket
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
38.
Health and Family Welfare #10551402 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Setrawa Block Dechu District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
39.
Health and Family Welfare #10545347 Price Bid
Tender For Construction Of Janta Clinic At Part Of Mact Court Building District Court Campus Pali - Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 2 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 3 20mm thick. 4 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand): Flush/ Ruled pointing 5 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils 6 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 7 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 8 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: 9 Cement Mortar 1:6 ( 1-Cement : 6-Sand). 10 Supplying and fixing Soorsagar Bhura or Equivalent ashlar sills, lintels and dassa, bearing, bed & top surface made perfenctly even, jambs, skirting steps etc. rough dressed: 11 Upto 15 cm. thick 12 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : 13 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 14 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 15 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 16 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : 17 Windows fixed 18 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tile confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 19 Size 300mm x 450mm 20 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. 21 size 600 mm X 600 mm 22 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 23 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 24 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 25 Commercial Veneer both side 26 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 27 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. 28 Jalore (P-white / S-white/ Rosy Pink colour) 29 Above 3601 Cm2 Slabs 30 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 31 Granite/Kota Stone Work 32 Full Edge moulding 33 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) 34 Light shade using shade cement. 35 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 36 Grade 304 37 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 38 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: 39 Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. 40 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 41 Two or more coats on new work 42 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 43 Deep groove pointing 44 Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. 45 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 46 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. 47 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 48 New Plastered Surface (three or more coats) 49 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). 50 For fixed portion 51 Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 52 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 53 Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 54 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. 55 Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 56 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) 57 With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 58 (Part B : Sanitary Works) P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 59 P & F water closet Seat Covers with brass hinges complete : 60 -do- White. 61 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. 62 Mini stall size 455x385x350mm. 63 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: 64 PVC with PVCbend as per IS : 7231 . 65 P & F C.P. brass Urinal Spreader for stall urinal of approved make. 66 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : 67 Size 510 mm x 400 mm 68 P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge 69 Size 500x400mm 70 P & F Towel Rail or Ring of approved quality/make: 71 C.P. brass Towel Rail elbow type with concealed screws size 600 mm (Heavy duty). 72 P & F Grating of approved quality/make: 73 Stainless Steel Sheet size 125mm dia. 74 P & F Soap Dish or Tray of approved quality/make 75 C.P. brass 76 P & F Extension Pipe for bib cocks of approved quality/make. 77 C.P. brass of Heavy & Superior quality 50x15mm 78 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 79 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: 80 C.P. Brass bib cock,15mm nominal bore. 81 (-do-) Long body, 15mm nominal bore weight not less than 690 gm 82 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: 83 C.P. Brass 15mm nominal bore. 84 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : 85 Brass wt.Not less than 400 gm, 20mm. 86 P & F 15 mm. Dia Connection Pipe of approved quality/make : 87 (-do-) 600mm. 88 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : 89 (-do-) 20mm nominal bore. 90 (-do-) 25mm nominal bore. 91 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 92 500 (-do-) 93 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 94 Hoisting Charges for each floor : 95 For items 2.26.1 to 2.26.4 96 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 97 20mm nominal size 98 25 mm nominal size 99 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. 100 Depth up to 0.5 M 101 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: 102 Size 240 Cm. dia outside & 240 Cm. depth. 103 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 104 75 mm dia 105 110 mm dia 106 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 107 Bend 87.5 Dg. 108 75mm dia 109 110mm dia 110 Bend 45 Dg. 111 110mm dia 112 Door Bend 87.5 Dg. 113 110mm dia 114 Pipe Clip 115 110mm dia 116 W.C. Connector (Bend) with ring 117 110mm dia 118 Single Tee 119 110mm dia 120 Nahni Trap with Jali 4” 121 110mm dia 122 Vent Cowel 123 110mm dia 124 (PART C : ELECTRICAL WORKS) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 125 Short point (up to 3 mtr.) 126 Medium point (up to 6 mtr.) 127 Long point(up to 10 mtr.) 128 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 129 S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along withISI marked (IS:14768 P-II 2003) accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required includingcutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 130 20 mm 131 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 132 1 x 1.5 sq.mm 133 1 x 2.5 sq.mm 134 1 x 4.0 sq.mm 135 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 137 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 139 Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 141 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Surface Mounting (with extruded alumn. Housing ) 143 Minimumlumen output 650 lm 144 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 LED Street Light fixture with Minimum lumen output 5600 lm 146 LED Street Light fixture with Minimum lumen output 7500 lm 147 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 148 25 mm Dia. 149 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 600mm , Min. Lumens output 1800 lmLED Tube rod with Polycarbonate Housing 151 P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Openingof following size and made out from 24 SWG GI sheet as per instructions of Engineer in chargeincluding fixing with suitable fasteners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 152 Suitable for 380 mm sweep Exhaust Fan 153 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 154 1.5 TR ISEER not less then 3.8 155 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 156 20 mm 157 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 158 4 kVA 159 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 160 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 161 10 Ltr. 162 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 163 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
40.
Shipping #10542895 Price Bid
Life Boat Davits And Winches Repair Jobs For The Vessel Rm0815; 1 Jobs on life boat davits and winches onboard the Vessel RM.0815 - 2 set (P & S) 2 SERVICE PART 3 D25037 Life falls of two sets to remove and renewed. New wire ship supply 4 D25037.1FOLLOWING JOBS TO BE DONE AT TWO SETS OF LIFEBOAT DAVITS:ALL SHEAVES ON EACH DAVIT TO BE REMOVED TOTAL 12 SHEAVES IN LIFE BOAT DAVIT). EACH CENTRE PIN AND ALL SHEAVES TO BE CHECKED FOR CRACKS; WEAR AND TEAR AND RENEWED WHERE NECESSARY. FLOATING BLOCKS (2 NO. AT EACH LIFEBOAT) TO BE OPENED UP; SIDE PLATES (CHEEKS) TO BE POWER TOOLED/GRIT BLASTED; CHECK FOR HOLES/THINNED DOWN PORTIONS AND RENEW AS NECESSARY. AFTER LUBRICATION; ALL SHEAVES AND FLOATING BLOCKS TO BE FIT IN PLACE WITH CENTRE PINS LOCKED CORRECTLY IN POSITION. 5 D25037.2 FIVE YEALY LOAD TEST AND ISSUE CERTIFICATE FOR 02 LIFEBOATS 6 D25037.3 TWO NUMBER FLOATING BLOCKS CHEEK PLATES OF EACH L/BOAT TO BE INSPECTED AND RENEWED /REPAIRED AS REQUIRED 7 D25037.4 LIFEBOAT CHOKE SUPPORTS FWD AND AFT TO BE RENEWED. 8 D25037.5 CHOKE WOODEN SUPPORT AND RUBBER PADDING TO RENEW. 9 D25037.6DAVIT ARM HEEL PINS TO BE REMOVEDINSPECTED FOR ANY PLAY AND REPAIRED / RENEWED AS REQUIRED. 10 D25037.7 FWD AND AFT GRIPES WIRE ROPES ANDEND TURNBUCKLES (3 NO) TO BE RENEWED OF BOTH LIFEBOATS. 11 D25037.8 FWD AND AFT ARM OF DAVIT; GUIDE FOR FLOATING BLOCK WIRE PIN REQUIRE RENEWAL ;GUIDE FOR THE ABOVE REQUIRE SUPPORT. 12 D25037.9 BOTH LIFEBOAT DAVIT TO BE POWER TOOLED COMPLETELYPRIMERED AND PAINTED 13 D25038 Life Boat Davit winch 14 D25038.1 TWO LIFEBOAT WINCHES TO BE OVERHAULED. TO BE RENEWED. GEAR OIL TO BE RENEWED WITH THE OWNER’S SUPPLY.TWO NOS. GAUGE GLASS TO BE CLEANED. 15 D25038.2 TWO LIFEBOAT DAVIT CENTRIFUGAL BRAKES AND RATCHETS TO BE OPENED UP AND INSPECTED FOR SATISFACTORY OPERATION IN PRESENCE OF SHIPS OFFICERS. IF REQUIRED NEW BRAKE LINING. TO BE FITTED OFF 8 MM THICKNESS.ON COMPLETION OF ABOVE JOBS BRAKE ASSEMBLES AND RATCHETS TO BE BOXED UP AND TESTED. 16 D25038.3 02 NO LIFE BOATS SELF LOWERING WIRES TO BE RENEWED. SIZE OF WIRE 4 MM SS NON KINKING TYPE 17 D25038.4 SELF LOWERING WIRE SHEAVE SUPPORT EYE TO RENEW 18 D25038.5 PORT/STBD SIDE HAND CRANKING HANDLE FOR DAVIT WINCH CORRODED; TO BE RENEWEDAPS 19 D25038.6 WINCH FOUNDATION TO BE REMOVED FROM PLACE FOR BOTTOM INSPECTION AND REFIT WITH NEW NUTS/BOLTS/PACKINGS 20 D25038.7 VENDOR TO ARRANGE FOR ALL THE ABOVE JOBS AND ALSO FIVE YEARLY SERVICINGINSPECTIONTESTING BY MANUFACTURER SERVICING ENGINEER AND ALSO CERTIFICATION. 21 D25038.10 CONDUIT BOX FOR LIFE BOAT HEAVING MOTOR TO REPAIRE 22 D25036.3 DYNAMIC LOAD TEST OF LIFE BOAT DAVIT WINCH BRAKE TO BE CARRIED OUT WITH A PROOF LOAD OF 1.1 TIMES THE MAXIMUM WORKING LOAD AT MAXIMUM LOWERING SPEED. 5 YEARLY SERVICING/INSPECTION/TESTING TO BE DONE AND CERTIFICATE TO BE ISSUED FOR SAME BY YARD AND WITNESSED BY CLASS/MMD SURVEYOR. OEM - NORSAFE WILL BE REQUIRED CARRY OUT SAME. 23 D25007.3 LIFEBOAT WINCH OPERATING HANDLES TO FABRICATE AND SUPPLY 24 E 25053:LIFE BOAT DAVIT WINCHX2 NOS 25 MAKE:ORIENTAL PRECISION & ENGINEERING CO.LTD.BUSAN KORE, WINCH DETAILSTYPE :BWE - 08 - 180 (PORT)BWE-08-030 (STBD) MAXIMUM DESIGN LOAD 4000 KG (39.2 KN), DAVIT DETAILS : TYPE HGD - 057 - 24 MAXI. DESIGN LOAD 5700 KG 26 E25053.1 1)BRAKE LININGS TO INSPECT AND RENEW IF REQUIRED. MATERIAL-NON ASBESTOS. 27 E25053.2 2)WINCH GEARS TO INSPECT FOR DAMAGES. GEAR CASING OIL TO RENEW. CARE MUST BE TAKEN TO AVOID DUST ETC. FROM ENTERING INTO GEAR CASE. 28 E25053.33)ONE WAY CLUTCH TO INSPECT AND FUNCTION TO SHOW TO CEO/2EO. 29 E25053.4 4)FOLLOWING TESTS TO BE CARRIED OUT TO THE SATISFACTION OF CEO/SUPDT. DEFECTS IF ANY TO RECTIFY.STATIC TEST 6000 KGS (58.9 KN)HOLDING CHECKWINCH STRENGHTHLOWERING TEST2329 KG (FULLY EQUIPT.) SPEEDBRAKELOWERING HT (MIN). 1451 KGS (EMPTY)MIN 3M SLIP DISTANCE (MAX. 1 M)HOISTING TESTPORT 2348KG FALL TAKE IN SPEED STBD2168 KGFALL TAKE IN SPEED DYNAMIC BRAKE TESTPORT / STBD4400 KG ( 43.2 KN) JOBS TO BE CARRIED OUT BY MAKERS SERVICE ENGINEER 30 MATERIAL PART 31 D25037 Life falls of two sets to remove and renewed. New wire ship supply 32 D25037.1FOLLOWING JOBS TO BE DONE AT TWO SETS OF LIFEBOAT DAVITS:ALL SHEAVES ON EACH DAVIT TO BE REMOVED TOTAL 12 SHEAVES IN LIFE BOAT DAVIT). EACH CENTRE PIN AND ALL SHEAVES TO BE CHECKED FOR CRACKS; WEAR AND TEAR AND RENEWED WHERE NECESSARY. FLOATING BLOCKS (2 NO. AT EACH LIFEBOAT) TO BE OPENED UP; SIDE PLATES (CHEEKS) TO BE POWER TOOLED/GRIT BLASTED; CHECK FOR HOLES/THINNED DOWN PORTIONS AND RENEW AS NECESSARY. AFTER LUBRICATION; ALL SHEAVES AND FLOATING BLOCKS TO BE FIT IN PLACE WITH CENTRE PINS LOCKED CORRECTLY IN POSITION. 33 D25037.2 FIVE YEALY LOAD TEST AND ISSUE CERTIFICATE FOR 02 LIFEBOATS 34 D25037.3 TWO NUMBER FLOATING BLOCKS CHEEK PLATES OF EACH L/BOAT TO BE INSPECTED AND RENEWED /REPAIRED AS REQUIRED 35 D25037.4 LIFEBOAT CHOKE SUPPORTS FWD AND AFT TO BE RENEWED. 36 D25037.5 CHOKE WOODEN SUPPORT AND RUBBER PADDING TO RENEW. 37 D25037.6DAVIT ARM HEEL PINS TO BE REMOVEDINSPECTED FOR ANY PLAY AND REPAIRED / RENEWED AS REQUIRED. 38 D25037.7 FWD AND AFT GRIPES WIRE ROPES ANDEND TURNBUCKLES (3 NO) TO BE RENEWED OF BOTH LIFEBOATS. 39 D25037.8 FWD AND AFT ARM OF DAVIT; GUIDE FOR FLOATING BLOCK WIRE PIN REQUIRE RENEWAL ;GUIDE FOR THE ABOVE REQUIRE SUPPORT. 40 D25037.9 BOTH LIFEBOAT DAVIT TO BE POWER TOOLED COMPLETELYPRIMERED AND PAINTED 41 D25038 Life Boat Davit winch 42 D25038.1 TWO LIFEBOAT WINCHES TO BE OVERHAULED. TO BE RENEWED. GEAR OIL TO BE RENEWED WITH THE OWNER’S SUPPLY.TWO NOS. GAUGE GLASS TO BE CLEANED. 43 D25038.2 TWO LIFEBOAT DAVIT CENTRIFUGAL BRAKES AND RATCHETS TO BE OPENED UP AND INSPECTED FOR SATISFACTORY OPERATION IN PRESENCE OF SHIPS OFFICERS. IF REQUIRED NEW BRAKE LINING. TO BE FITTED OFF 8 MM THICKNESS.ON COMPLETION OF ABOVE JOBS BRAKE ASSEMBLES AND RATCHETS TO BE BOXED UP AND TESTED. 44 D25038.3 02 NO LIFE BOATS SELF LOWERING WIRES TO BE RENEWED. SIZE OF WIRE 4 MM SS NON KINKING TYPE 45 D25038.4 SELF LOWERING WIRE SHEAVE SUPPORT EYE TO RENEW 46 D25038.5 PORT/STBD SIDE HAND CRANKING HANDLE FOR DAVIT WINCH CORRODED; TO BE RENEWEDAPS 47 D25038.6 WINCH FOUNDATION TO BE REMOVED FROM PLACE FOR BOTTOM INSPECTION AND REFIT WITH NEW NUTS/BOLTS/PACKINGS 48 D25038.7 VENDOR TO ARRANGE FOR ALL THE ABOVE JOBS AND ALSO FIVE YEARLY SERVICINGINSPECTIONTESTING BY MANUFACTURER SERVICING ENGINEER AND ALSO CERTIFICATION. 49 D25038.10 CONDUIT BOX FOR LIFE BOAT HEAVING MOTOR TO REPAIRE 50 D25036.3 DYNAMIC LOAD TEST OF LIFE BOAT DAVIT WINCH BRAKE TO BE CARRIED OUT WITH A PROOF LOAD OF 1.1 TIMES THE MAXIMUM WORKING LOAD AT MAXIMUM LOWERING SPEED. 5 YEARLY SERVICING/INSPECTION/TESTING TO BE DONE AND CERTIFICATE TO BE ISSUED FOR SAME BY YARD AND WITNESSED BY CLASS/MMD SURVEYOR. OEM - NORSAFE WILL BE REQUIRED CARRY OUT SAME. 51 D25007.3 LIFEBOAT WINCH OPERATING HANDLES TO FABRICATE AND SUPPLY 52 E 25053:LIFE BOAT DAVIT WINCHX2 NOS 53 MAKE:ORIENTAL PRECISION & ENGINEERING CO.LTD.BUSAN KORE, WINCH DETAILSTYPE :BWE - 08 - 180 (PORT)BWE-08-030 (STBD) MAXIMUM DESIGN LOAD 4000 KG (39.2 KN), DAVIT DETAILS : TYPE HGD - 057 - 24 MAXI. DESIGN LOAD 5700 KG 54 E25053.1 1)BRAKE LININGS TO INSPECT AND RENEW IF REQUIRED. MATERIAL-NON ASBESTOS. 55 E25053.2 2)WINCH GEARS TO INSPECT FOR DAMAGES. GEAR CASING OIL TO RENEW. CARE MUST BE TAKEN TO AVOID DUST ETC. FROM ENTERING INTO GEAR CASE. 56 E25053.33)ONE WAY CLUTCH TO INSPECT AND FUNCTION TO SHOW TO CEO/2EO. 57 E25053.4 4)FOLLOWING TESTS TO BE CARRIED OUT TO THE SATISFACTION OF CEO/SUPDT. DEFECTS IF ANY TO RECTIFY.STATIC TEST 6000 KGS (58.9 KN)HOLDING CHECKWINCH STRENGHTHLOWERING TEST2329 KG (FULLY EQUIPT.) SPEEDBRAKELOWERING HT (MIN). 1451 KGS (EMPTY)MIN 3M SLIP DISTANCE (MAX. 1 M)HOISTING TESTPORT 2348KG FALL TAKE IN SPEED STBD2168 KGFALL TAKE IN SPEED DYNAMIC BRAKE TESTPORT / STBD4400 KG ( 43.2 KN) JOBS TO BE CARRIED OUT BY MAKERS SERVICE ENGINEER
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
41.
Communications and Information Technology  #10536608 Price Bid
Rate Contract For Call Basis Repairing Servicing Shifting Of Dg Sets Mis Works In Various Te Bts Sites Rjio Sites Under Distt Hanumangarh , Visit Charges To Attend Fault Of Dea Set On Call Basis / Complaint Basis At Different Te / Bts Sites Under Jurisidication Including Attending The Minor Faults Involving No Material And Submit Detailed Report For Major Fault To The Engineering -In-Charge I/C Fare Charges To Visit The Site From Hq Etc Complete As Reqd . , Note:- The Charges Shall Be Paid Proportinately To Attend The Complaints E . G . 3 Sites For Visit Up To 30 Kms On A Route , 2 Sites For Visit More Than 30 Km & Up To 60 Km On A Route And 1 Site For Visit Beyond 60 Km From Hq . , General Servicing Of Following Capacity Of Dea Sets Of Different Makes And Models Under Various Exchanges Comprising Of Cleaning & Greasing Of The Parts , Tappet Setting , Fan Belt , Tensioner Pulley And Lever Adjustments , Testing & Checking Of Ac & Dc Wiring , Self & Charging Alternator Cleaning And Testing , Checking Of Working & Minor Fault Removal , Checking Of Fuel Pipes I/C Transportation , Labour Charges & Minor Material Required For Servicing Etc . As Reqd . , Up To 30Kva Dea Set . , Beyond 30Kva And Up To 75Kva Dea Sets , Providing Of Following Items I/C Removal Of Existing Defective Parts / Items / Material Etc . In Different Capacity Dea Sets Of Different Makes And Models Under Various Exchanges I/C Testing / Commissioning Etc . Complete As Reqd . , Lubricating Oil As Per Manufacturer Recommendation , Coolant For Radiator , Engine Shut Off Solenoid ( 12 Volt ) . , Steel Wire Braided Fuel Pipe Along With Banjo Bolt And Washers . , Copper Battery Leads Of Standard Length And Size Along With Terminals ( Red And Black ) . , Mechanical Type Rpm Cum Hr Meter ( M/S Pricol Or Ss Make ) , Mechanical Type Rpm Cum Hr Meter Chain ( M/S Pricol Or Ss Make ) , Hose Pipe Set , Starting Key Switch , Diesel Filter , Oil Filter ( 1/2 Or 1 . 0 Ltr ) , Labour Charges For Top Overhauling/ Major/ Minor Overhaulling Of The Different Capacity And Various Makes And Models Dea Sets As Per Manufacturer Recommendations I/C Dismentalling , And Replacement Of All The Filters Like Oil Filters , Air Filter , Tappet Setting , Injector Setting , Replacement Of Belts , Safties And Meters As Reqd . Cleaning Of All Carbonised Parts , Radiator Cleaning And Replacement Of Engine Oil , Coolent , Calibration Of Engine As Per Manufaturers Reccommendations Etc As Required . ( Only For Labour Charges Without General Servicing Job I/C Transportation , Dismentling And Assembling Charges ) , ( A ) Up To 30 Kva Dea Set , ( B ) From More Than 30 Kva To 75 Kva Dea Set , Removal Of Following Faulty/ Burnt/ Damage Parts In The Existing Up To 30Kva Dea Sets And Providing & Fixing Of New Parts As Mentioned Under To Bring The Engine In Healthy Condition Etc . Complete As Reqd . , Radiator Hose Connections ( Supply And Return ) . , Main Bearing Assembly . , Piston Assembly . , Piston Rings Set . , Liner With O-Ring . , Oil Seal Set . , Connecting Rod Bearing Set . , Repairing Of Head Including Replacement Of Valves Pairs , Seats , Guides Etc . . , Set Of Gasket I/C Head Gasket . , Set Of O-Rings . , V-Belt Set . , Fuel Feed Pump Kit . , Air Cleaner Hose . , Air Cleaner Filter Element ( For Dry Type Cleaner ) . , C . R Bush , Came Bush , Valve Seat , Steam Seal , Removal Of Following Faulty / Burnt / Damage Parts In The Existing Beyond 30Kva But Up To 75Kva Dea Sets For Major/Minor Overhauling And Providing & Fixing Of New Parts As Mentioned Under To Bring The Engine In Healthy Condition Etc . Complete As Reqd . , Radiator Hose Connections ( Supply And Return ) . , Main Bearing Assembly . , Piston Assembly . , Piston Rings Set . , Liner With O-Ring . , Oil Seal Set . , Connecting Rod Bearing Set . , Repairing Of Head Including Replacement Of Valves Pairs , Seats , Guides Etc . . , Set Of Gasket I/C Head Gasket . , Set Of O-Rings . , V-Belt Set . , Fuel Feed Pump Kit . , Air Cleaner Hose . , Air Cleaner Filter Element ( For Dry Type Cleaner ) . , C . R Bush , Came Bush , Valve Seat , Steam Seal , Radiator ( Complete Assembly Up To 75 Kva ) , Replacement Of The Following Parts/ Items In Existing Different Capacity And Make E/A Set Amf/ Manual Control Panels I/C Dismantling Of Faulty Parts , Fixing The New In Place Of Faulty Parts , Testing Etc As Reqd . ( Note- Make And Model As Per Manufacturer Recommendation And To Be Get Approved From Engineer-In-Charge Where Ever Not Specified ) . , Power Diode For Rotating Rectifier Assembly , Smps Battery Charger 12 Volt Dc Complete As Required Etc . , Pdg Complete Servicing And Repairing , Rewinding Of Battery Charging Alternator/ Dynamo I/C Dismantling Of Equipment , Greasing And Oiling Of Bearings And Other Parts , Repairing Of Rectifier Assembly , Replacement Of Carbon Brush , Repairing Of Fuses , Cut-Off Plate Etc . Complete As Required . , Repairing & General Servicing Of The Existing Faulty Radiator In Existing Dea Set By Repairing Of Leakage And Cleaning Of Copper Tubes With Help Of Cleaning Agents , Dismantling Of Radiator Assembly Including Transportation , Brazing And Testing For Leakage And Re-Installation After Repairing The Same Etc . Reqd . , Up To 30Kva Dea Set . , Beyond 30Kva And Up To 75Kva Dea Sets , Pdg General Servicing And Repairing Of 12 Volts Engine Starting Self I/C Dismantling , Greasing And Oiling Of Bearing And Other Parts , Cleaning , Replacement Of Bandex Gear , Carbon Brush , Rewinding Etc . Complete Checking Of Self And Testing And Fitting With Proper Alignment Etc . Complete As Reqd . , Supplying And Fixing Of 12 Volts Lead Acid Battery Of Following Capacity For E/A Sets , I/C Initial Charging , Battery Terminals , Transportation , Testing , Commissioning Etc . Complete As Reqd . , 88/90 Ah , 120/130 Ah , 150/165 Ah , Crankshaft Grinding Of Existing Engines Of Different Make And Models At Bsnl Te/ Bts Sites I/C Dismantling Of Crankshaft , Refitting After Grinding On Lathe Machine Up To Suitable Accuracy Required For Connecting Rod & Main Bearing I/C Transportation , Dismantling And Re-Fixing After Repairing Etc . As Reqd . , Up To 30Kva Dea Set . , Beyond 30Kva And Up To 75Kva Dea Sets , Repairing Of Fuel Injection Pump ( Fip ) , Nozzle & Injectors I/C Dismantling , Transportation Of Pump , Cleaning , Repairing , Testing And Refitting The Same On The Existing E/A Set I/C Replacement Of Faulty Components Etc . Complete As Reqd . ( Service & Testing Shall Be Done At Authorized Work Shop And Its Report Shall Be Submitted To Engineer-In-Charge ) . , Transporatation Of Alternator For Approx . Average Distance Of 150 Km Subject To Variation In Either Side From Sub Division Hq Up To 100 Kva Capacity From Bts Site To Workshop At Sub Division Head Quarter Area & Back After Repairing I/C Dismentling , Loading , Unloading , Transportation , Safe Handling & Commssioning After Repairing Etc . Complete As Reqd . , Rewinding Of Main Stator/Main Rotor Winding For Alternator Capacity With Proper Guage Copper Wire / Strip I/C Dismentling The Faulty Wiring , Rewinding , Testing Etc . Complete As Reqd . , Up To 30 Kva Dea Set , From More Than 30 Kva To 75 Kva Dea Set , Rewinding Of Exciter Rotor/Excitor Stator Winding/Stator Winding For Alternator With Proper Guage Copper Wire / Strip I/C Dismentling The Faulty Wiring , Rewinding , Testing Etc . Complete As Reqd . , Up To 30 Kva Dea Set , From More Than 30 Kva To 75 Kva Dea Set , Tranportation Charges For Trolley Mounted/Existing Dea Set Dea Set Capacity Up To 75 Kva Alongwith Canopy/Without Canopy , Control Panel , Exhaust Pipe , Silencer , Fuel Tank , Avm Pads , Power Cable And All Other Accessories I/C Toeing Arrangement With Help Of Jeep / Tractor Etc . Complete As Req
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
42.
Communications and Information Technology  #10536605 Price Bid
Rate Contract For Call Basis Repairing Servicing Shifting Of Dg Sets And Misc Works In Various Te Bts Sites Rjio Sites Under Distt . Sri Ganganagar , Visit Charges To Attend Fault Of Dea Set On Call Basis / Complaint Basis At Different Te / Bts Sites Under Jurisidication Including Attending The Minor Faults Involving No Material And Submit Detailed Report For Major Fault To The Engineering -In-Charge I/C Fare Charges To Visit The Site From Hq Etc Complete As Reqd . , Note:- The Charges Shall Be Paid Proportinately To Attend The Complaints E . G . 3 Sites For Visit Up To 30 Kms On A Route , 2 Sites For Visit More Than 30 Km & Up To 60 Km On A Route And 1 Site For Visit Beyond 60 Km From Hq . , General Servicing Of Following Capacity Of Dea Sets Of Different Makes And Models Under Various Exchanges Comprising Of Cleaning & Greasing Of The Parts , Tappet Setting , Fan Belt , Tensioner Pulley And Lever Adjustments , Testing & Checking Of Ac & Dc Wiring , Self & Charging Alternator Cleaning And Testing , Checking Of Working & Minor Fault Removal , Checking Of Fuel Pipes I/C Transportation , Labour Charges & Minor Material Required For Servicing Etc . As Reqd . , Up To 30Kva Dea Set . , Beyond 30Kva And Up To 75Kva Dea Sets , Providing Of Following Items I/C Removal Of Existing Defective Parts / Items / Material Etc . In Different Capacity Dea Sets Of Different Makes And Models Under Various Exchanges I/C Testing / Commissioning Etc . Complete As Reqd . , Lubricating Oil As Per Manufacturer Recommendation , Coolant For Radiator , Engine Shut Off Solenoid ( 12 Volt ) . , Steel Wire Braided Fuel Pipe Along With Banjo Bolt And Washers . , Copper Battery Leads Of Standard Length And Size Along With Terminals ( Red And Black ) . , Mechanical Type Rpm Cum Hr Meter ( M/S Pricol Or Ss Make ) , Mechanical Type Rpm Cum Hr Meter Chain ( M/S Pricol Or Ss Make ) , Hose Pipe Set , Starting Key Switch , Diesel Filter , Oil Filter ( 1/2 Or 1 . 0 Ltr ) , Labour Charges For Top Overhauling/ Major/ Minor Overhaulling Of The Different Capacity And Various Makes And Models Dea Sets As Per Manufacturer Recommendations I/C Dismentalling , And Replacement Of All The Filters Like Oil Filters , Air Filter , Tappet Setting , Injector Setting , Replacement Of Belts , Safties And Meters As Reqd . Cleaning Of All Carbonised Parts , Radiator Cleaning And Replacement Of Engine Oil , Coolent , Calibration Of Engine As Per Manufaturers Reccommendations Etc As Required . ( Only For Labour Charges Without General Servicing Job I/C Transportation , Dismentling And Assembling Charges ) , ( A ) Up To 30 Kva Dea Set , ( B ) From More Than 30 Kva To 75 Kva Dea Set , Removal Of Following Faulty/ Burnt/ Damage Parts In The Existing Up To 30Kva Dea Sets And Providing & Fixing Of New Parts As Mentioned Under To Bring The Engine In Healthy Condition Etc . Complete As Reqd . , Radiator Hose Connections ( Supply And Return ) . , Main Bearing Assembly . , Piston Assembly . , Piston Rings Set . , Liner With O-Ring . , Oil Seal Set . , Connecting Rod Bearing Set . , Repairing Of Head Including Replacement Of Valves Pairs , Seats , Guides Etc . . , Set Of Gasket I/C Head Gasket . , Set Of O-Rings . , V-Belt Set . , Fuel Feed Pump Kit . , Air Cleaner Hose . , Air Cleaner Filter Element ( For Dry Type Cleaner ) . , C . R Bush , Came Bush , Valve Seat , Steam Seal , Removal Of Following Faulty / Burnt / Damage Parts In The Existing Beyond 30Kva But Up To 75Kva Dea Sets For Major/Minor Overhauling And Providing & Fixing Of New Parts As Mentioned Under To Bring The Engine In Healthy Condition Etc . Complete As Reqd . , Radiator Hose Connections ( Supply And Return ) . , Main Bearing Assembly . , Piston Assembly . , Piston Rings Set . , Liner With O-Ring . , Oil Seal Set . , Connecting Rod Bearing Set . , Repairing Of Head Including Replacement Of Valves Pairs , Seats , Guides Etc . . , Set Of Gasket I/C Head Gasket . , Set Of O-Rings . , V-Belt Set . , Fuel Feed Pump Kit . , Air Cleaner Hose . , Air Cleaner Filter Element ( For Dry Type Cleaner ) . , C . R Bush , Came Bush , Valve Seat , Steam Seal , Radiator ( Complete Assembly Up To 75 Kva ) , Replacement Of The Following Parts/ Items In Existing Different Capacity And Make E/A Set Amf/ Manual Control Panels I/C Dismantling Of Faulty Parts , Fixing The New In Place Of Faulty Parts , Testing Etc As Reqd . ( Note- Make And Model As Per Manufacturer Recommendation And To Be Get Approved From Engineer-In-Charge Where Ever Not Specified ) . , Power Diode For Rotating Rectifier Assembly , Smps Battery Charger 12 Volt Dc Complete As Required Etc . , Pdg Complete Servicing And Repairing , Rewinding Of Battery Charging Alternator/ Dynamo I/C Dismantling Of Equipment , Greasing And Oiling Of Bearings And Other Parts , Repairing Of Rectifier Assembly , Replacement Of Carbon Brush , Repairing Of Fuses , Cut-Off Plate Etc . Complete As Required . , Repairing & General Servicing Of The Existing Faulty Radiator In Existing Dea Set By Repairing Of Leakage And Cleaning Of Copper Tubes With Help Of Cleaning Agents , Dismantling Of Radiator Assembly Including Transportation , Brazing And Testing For Leakage And Re-Installation After Repairing The Same Etc . Reqd . , Up To 30Kva Dea Set . , Beyond 30Kva And Up To 75Kva Dea Sets , Pdg General Servicing And Repairing Of 12 Volts Engine Starting Self I/C Dismantling , Greasing And Oiling Of Bearing And Other Parts , Cleaning , Replacement Of Bandex Gear , Carbon Brush , Rewinding Etc . Complete Checking Of Self And Testing And Fitting With Proper Alignment Etc . Complete As Reqd . , Supplying And Fixing Of 12 Volts Lead Acid Battery Of Following Capacity For E/A Sets , I/C Initial Charging , Battery Terminals , Transportation , Testing , Commissioning Etc . Complete As Reqd . , 88/90 Ah , 120/130 Ah , 150/165 Ah , Crankshaft Grinding Of Existing Engines Of Different Make And Models At Bsnl Te/ Bts Sites I/C Dismantling Of Crankshaft , Refitting After Grinding On Lathe Machine Up To Suitable Accuracy Required For Connecting Rod & Main Bearing I/C Transportation , Dismantling And Re-Fixing After Repairing Etc . As Reqd . , Up To 30Kva Dea Set . , Beyond 30Kva And Up To 75Kva Dea Sets , Repairing Of Fuel Injection Pump ( Fip ) , Nozzle & Injectors I/C Dismantling , Transportation Of Pump , Cleaning , Repairing , Testing And Refitting The Same On The Existing E/A Set I/C Replacement Of Faulty Components Etc . Complete As Reqd . ( Service & Testing Shall Be Done At Authorized Work Shop And Its Report Shall Be Submitted To Engineer-In-Charge ) . , Transporatation Of Alternator For Approx . Average Distance Of 150 Km Subject To Variation In Either Side From Sub Division Hq Up To 100 Kva Capacity From Bts Site To Workshop At Sub Division Head Quarter Area & Back After Repairing I/C Dismentling , Loading , Unloading , Transportation , Safe Handling & Commssioning After Repairing Etc . Complete As Reqd . , Rewinding Of Main Stator/Main Rotor Winding For Alternator Capacity With Proper Guage Copper Wire / Strip I/C Dismentling The Faulty Wiring , Rewinding , Testing Etc . Complete As Reqd . , Up To 30 Kva Dea Set , From More Than 30 Kva To 75 Kva Dea Set , Rewinding Of Exciter Rotor/Excitor Stator Winding/Stator Winding For Alternator With Proper Guage Copper Wire / Strip I/C Dismentling The Faulty Wiring , Rewinding , Testing Etc . Complete As Reqd . , Up To 30 Kva Dea Set , From More Than 30 Kva To 75 Kva Dea Set , Tranportation Charges For Trolley Mounted/Existing Dea Set Dea Set Capacity Up To 75 Kva Alongwith Canopy/Without Canopy , Control Panel , Exhaust Pipe , Silencer , Fuel Tank , Avm Pads , Power Cable And All Other Accessories I/C Toeing Arrangement With Help Of Jeep / Tractor Etc . Co
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
43.
Water Resources and Irrigation #10512078 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation, Furnishing Of Existing Barrage Control Room At Gaula, Barrage, Haldwani, Uttarakhand Under National Hydrolog , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification. , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Gaula Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimumone Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
44.
Water Resources and Irrigation #10512072 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification, Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Under National Hydrology Project , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Condition System With Requisite Furniture And Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification Located At Adwa Barrage, Mirzapur , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Ramnagar Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimum One Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
45.
Science and Technology #10497935 Price Bid
Tender For Annual Maintenance Contract Of Lab Buildings Of Iip. ( Electrical Works ) 2022-23. -Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5Sqmm Frls Pvc Insulated Copper Conductor Single / Multi Core Cable In Surface / Recessed Steel Conduit Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point / With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit ( Akg / M-Key ) , With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. 2 Group-A 3 Wiring For Circuit / Submain Wiring Along With Earth Wire The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit ( Akg / Plaza / Kaliga ) As Required 4 2 X 1.5 Sq Mm + 1X 1.5 Sq Mm Earthwire 5 2X2.5 Sq Mm + 1X2.5 Sq Mm Earth Wire 6 2X4 Sq Mm +1X4 Sq Mm Earth Wire 7 2X6 Sq Mm + 1X6 Sq Mm Earth Wire 8 4 X 4 Sq Mm + 2X 4 Sq Mm Earth Wire 9 Supplying And Drawing Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( Havells / Polycab ) 10 3 X 1.5 Sq Mm 11 3 X2.5 Sq Mm 12 3 X 4 Sq Mm 13 3 X 6 Sq M 14 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed / Pvc Conduit As Required. 15 2 Pair 16 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recessed Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Akg / M-Key ) 17 20 Mm 18 25 Mm 19 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recessed Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Akg / M-Key ) 20 20 Mm 21 25 Mm 22 Supplying And Fixing Metal Box Of Following Size ( Nominal Size ) On Surface Or In Recessed With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required. 23 100 Mmx 100 Mmx 60 Mm Deep 24 180 Mmx 100 Mmx 60 Mm Deep 25 200 Mmx 125 Mmx 60 Mm Deep 26 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc As Required. 27 5 / 6 Amps Switch 28 2 Way 5 / 6 Amps Switch 29 15 / 16 Amps Switch 30 3 Pin 5 / 6 Amps Socket Oulet 31 6 Pin 15 / 16 Amps Socket Oulet 32 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc As Required. 33 5 / 6 Amps Switch 34 2 Way 5 / 6 Amps Switch 35 15 / 16 Amps Switch 36 3 Pin 5 / 6 Amps Socket Oulet 37 6 Pin 15 / 16 Amps Socket Oulet 38 3 Pin 5 / 6 Amps Socket Oulet 39 Supplying And Fixingtwo Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required 40 Supplying And Fixingfollowing Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switch In Recess Etc As Required 41 1 Or 2 Module ( 75 Mm X 75 Mm ) 42 3 Module ( 100 Mm X 75 Mm ) 43 6 Module ( 200 Mm X 75 Mm ) 44 8 Module ( 125 Mm X 125 Mm ) 45 12 Module ( 200 Mm X 150 Mm ) 46 Supplying And Fixing Following Metal Box Of 180Mm X 100Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Fornt Including Providing And Fixing 6Pin 5A & 15 A Socket Outlet And 15 A Piano Type Switch, Connection, Painting Etc. As Required . 47 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 6 Pin 5 / 6 And 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required 48 Supplying And Fixing 3 Pin, 5A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required 49 Providing And Fixing Plain 16 / 0.20Mm ( 0.50Sqmm ) Twin Flat Flexible, Frls Pvc Insulated, Copper Conductor Cable, In Pvc Sleeve Of Suitable Size On The Floor / Wall, Or Side Of The Table / Door Etc. As Required. 50 Installation, Testing And Commissioning Of Pre-Wired Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Compelete With All Accessories And Tube Etc.Directly On Ceiling / Wall, Including Connection With 1.5 Sq Mm Fr Pvc Insulated Copper Conductor, Single Core Cable And Earthing Etc. As Required. 51 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rod Of Standrand Lenght ( Up To 30Cm ) With 1.5 Sq.Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required 52 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc As Requied Upto 450 Mm . 53 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 54 1 Run Of Cable 55 Providing And Fixing Following Rating And Breaking Capacity Mccb In Existing Cubical Panel Board Including Drilling Holes In Cubical Panel, Making Connections Etc As Required 56 200 Amp, 25 Ka, Tp Mccb 57 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415V Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mountingmcbs ( But Without Mcbs And Incomer ) As Required 58 12 Way, ( 4 + 36 ) Double Door 59 Supplying And Fixing 5 Amps To 32 Amps Rating, 240V / 415V, C Curve, Miniture Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connection, Testingand Commissioning Etc. As Required 60 Single Pole 61 Single Pole And Neutral 62 Double Pole 63 Tripple Pole 64 Tripple Pole And Neutral 65 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connetionx, Testing And Commissioning Etc. As Required. 66 40 Amps 67 63 Amps 68 Supplying And Fixing Following Rating, Four Pole, 415V, Isolator In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc. As Reqired. 69 40 Apms 70 63 Apms 71 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Rcc / Hume / Metal Pipe Etc. As Required. 72 Upto 35 Sq Mm 73 Above 35 Sq Mm And Upto 95 Sq Mm 74 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Masonry Open Duct As Required Etc. As Required. 75 Upto 35 Sq Mm 76 Above 35 Sq Mm And Upto 95 Sq Mm 77 Laying And Fixing Of One Number Pvc Inslulated And Pvc Sheated / Xlpe Power Cable Of 1.1Kv Grade Of Following Size On Wall Surface As Required. 78 Upto 35 Sq Mm ( Clamped With 1Mm Thick Saddle ) 79 Above 35 Sq Mm And Upto 95 Sq Mm ( Clamped With 25X3mm Ms Flat Clamp ) 80 Above 95 Sq Mm And Upto 185 Sq Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 81 Supplying And Fixing 32 / 40 Mm Dia X 2.00 Meters Long G.I Pipe ( Meidum Class ) Bracket For Mounting Of Fiuorscent / Hpmv / Hpsv Street Light Fitting On Pole Including Bendingshape, 2 Nos. 40 Mmx 3Mm Flat Iron Clamps With Nuts, Bolts Andthe Pipe To The Require Washer, Painting The Flat Iron Primer And Finish Piant Etc As Required. 82 Supplying And Laying Of Following Sizedwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc.Conforming Tois 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 83 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 84 Supplying, Installation, Testing And Commissioning Of Passive Infrared ( Pir ) Technology Base Occupancy Sensor Having High Preformance, Non Regulating Programmable Type, Suitable For Connected Load Upto 10A, For Mounting Height Up To 2.8 Meter And 5 Meter Diameter Coverage Area Along With Necessary Fixing Arrangements I / C Programming At Site Complete As Required. 85 Supplying, Installation, Testing And Commissioning Of Astronomical Time Switch Of Following Configuration To Be Mounted In Feeder Pillars / Lighitng Dbs For Automatic Switching On & Off Of Street Lights At Sun Set & Sun Reise Or Twilight ( Auto On, Off, Auto Modes ) With Manual Override Facility With 12 / 24 Hour Display Format With Suitable Battery And Indication For Relay Status I / C Programming At Site Complete As Required. 86 1 Out Put Per Phase Suitable For Single Phase Supply 87 Supply Of Labour For Attending Day To Day Complaints Complaints Of Electrical Maintenance Work For Repair And Replacement Of All Electrical Accessories In Non Workingelectrical Fittings And Fixture ( Such Main Boards, Fans, Geysers Switches, Sockets, Light Fittings, Motors, Starters, Street Light, Energy Meters In Lab Buildings, Underground And Overhead Line Distribution Network Including Service Main, Operation And Maintenance 33Kv 044Kv Substation And Power House ( 24 Hour Round The Clock ) All Other Electrical Work As Assigned By Site-Incharge. 88 Skilled Labour In Electrical Trade 89 Unskilled Labour In Electrical Trade 90 Attending Day To Day Complaints Of No Light / Non Working Points / Providing Temporary Connections In Iip Lab Buildings, Hostel & Guest House Etc As Required. 91 Supplying And Fixing Rj45 Outlet Information Module In Exsiting Modular Box Etc As Required. 92 Supplying And Fixingmodular Surface Mount Box With Modular Plate For Telephone Wiring With Telephone Deluxe Jack Single Outlet On Surface Or In Recessed Etc As Required. 93 Supplying, Fixing And Commissioning Of Heavy Duty Exhaust Fan Of 380 Mm Sweep 900 / 1400 Rpm / Turbojet Sp, Hd Suitable For 230V 50Hz Ac Supply Complete With Blade, Regular, Frame And Moving System Etc As Required .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 94 Supplying Of Ceiling Fan Of 1400 Mm Sweep, With Heavy Fins , High Quality Engineering, Energy Saving, Decorative Pacer Model ( White / Brown / Lovery ) Suitable For 230 V, Single Phase, 50 Hz Supply Including 600 Mm Long Down Rod And Electronic Regulator Etc…As Required. The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 95 Supplying And Laying Of Following Size Isi Marked Pvc Insulated And Pvc Sheathed / Xlpe / Frls Aluminium Conductor Steel Armoured Alumimium Cable Of 1.1Kv Grade As Required. 96 2 X 16 Sqmm 97 Supplying And Fixing Following Rating 415 / 230V C Series, Miniture Circuit Breaker Suitable For Lighting And Other Load Of Following Poles In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc As Required 98 Double Pole, 63 Amps 99 Tripple Pole And Neural, 63 Amps 100 Supply And Fabrication Of Sheet Steel Mcb Enclosure Fitted With Din Rail For Mcb Of Following Rating Complete With Connections Including Drilling Holes Etc As Required. 101 Double Pole Enclosure 102 Four Pole Enclosure 103 Supplying And Fixing 8 Module Flush Box Of 210 Mmx 75 Mm Size On Surface Or Recessed With Suitable Size Of 8 Module Front Sheet Cover In Front Including Providing And Fixing 6A, 5 Pin Module Socket 02 Nos And 6-16A, 3Pin Combined Modular Socket 01 No 10 A Sp Mini Mcb -01 No Etc As Required 104 Supplying And Fixing 6 Module Flush Box Of 200 Mm X 75 Mm Size On Surface Or Recessed With Suitable Size Of 6 Module Front Sheet Cover Of Make In The Front Including Providing And Fixing 20A One Way Modular Switch 02 Nos And 6-16 A, 3 Pin Combined Modular Socket 02 No Connecton, Painting Etc As Required. 105 Supply And Replacemant Of Capacitor Of Ceiling Fans / Exhaust Fan / Wall Fan / Padestal Fan Of Size Of 2.5 To 4 Mfd Etc As Required 106 Supply & Replacement Of 16 Amp. Plug Top, 3 Pin ( Crabtree / Anchor ) 107 Supply & Replacement Of 6 Amp. Plug Top, 3 Pin ( Crabtree / Anchor ) 108 Supply And Fixing Of Following Led Energy Saving Surface / Pendent Mounting Led Lamp Fitting With Powder Coated / Batten With In Bulit Electronic Ballast With Decortive End Caps Etc. As Required. 109 1 X 4 X 20W Led Luminaries With Tube Rod. 110 2 X 4 X 20W Led Luminaries With Tube Rod. 111 Supplying And Fixing Following High Efficiency Led Tube Rod Lamps Led Luminaire In Existing Fitting Fixture With Connection Etc. As Required. 112 4 X 20W Led Luminaries Tube Rod. 113 Supplying And Fixing Led Tube Rod 18 Watt 2 Feet Single Side Connection Ultra Bright Led Polycarbonate Tube Rod With High Efficinsyfor Installation In Exiisting Suitable Fittings. 114 Overhauling, Rewinding Oiling Greasing Of Ceiling Fan / Exhaust Fan / Pedsetal Fan / Wall Fan Of Any Size Including Supply And Replacement Of Ball Bearing / Bush Capacitor , Split Pin Rubber Wire, Shaft, Nut & Bolt 2X1.5 Sqmm Copper Connecting Wire, Cleaning Varnishing , Revolving Attechment And Step Regulator With Resistence Of Wall And Pedestal Fan Etc Complete In All Respect As Required. 115 1400 Mm Ceiling Fan Rewinding 116 Supply And Commissioning Of Indoor Recess / Surface 600X600mm ( 2X2 ) Led Luminaire 42W With High Luman Package Etc As Required.The Product Features Special Glare Cut Optics To Ensure Low Luminaire Luminance And Is Perfect For General And Office Lighting Applications Such As Workstations, Meeting Rooms And Cabins, Corridors And Break Areas. ( Havells / Wipro / Philiphs / C&S ) The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 117 Supplying And Fixing 15 Watt, 6000K New Generation Led Post Of Lanturn Light Luminare Ip 65, Energy Saving, Enviornmental Friendly, Long Life Aesthetically Designed With Symmetrical Light Distribution, Spun Aluminium Lad Scape Luminaire With High Power Leds As Light Souce. Clear Cover Offers Bright Illumination For Different Application. ( Havells / Wipro / Philiphs / C&S ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 118 S / R Of Following Watt Led Strret Luminaire, New Genration Energy Savin And Enviornmental Friendly Long Life Led Street Light Made Uo Of Pressure Die Cast Aluminium Housing With High Efficiency Led S Lighting Source And Toughened Glass Having Bottom Opening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07. ( Bajaj / Havells / Philiphs / Wipro ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 119 25 Watt Led Luminaire 120 30 W Led Luminaire 121 Supplying And Fixing Surface / Recess Mounting Led Panel Fitting Fixture 10 W ( 1X 1 ) , Elegantly Designed Sleek Recessed Mounted Pressure Die- Cast Alumium Luminaire In Powder Coated White Finish In Square Profile With Optimized Heat Sink For Efficient Heat Dissipation And Indepndent Elctronic Led Driver With Connection All Etc As Required. The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 122 Supplying And Drawing Folowing Size Of Pvc Insulated Aluminium Flat Twin Core Weather Proof Cabe In Existing Pipe Or Surface Etc As Required. 123 2X 4Sq Mm 124 2X6sq Mm 125 Supplying Of Wall Fan Of 400 Mm Sweep, 5 Star , Energy Saving, Decorative Pacer Model ( White / Brown / Lovery ) Suitable For 230 V, Single Phase, 50 Hz Supply Including All Etc…As Required. ( Havells / Bajaj / Usha ) .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 126 Supplying And Fixing 50 W Turbo Led Floodlight Luminaure, Energy Saving, Enviornmental Friendly, Long Life, One Desig For Aesthetic Consistancy In Multi Purpose Application With Smd Leds As Light Source With Driver Included, Suitable For Highliting Architectural Features Or Area Lighting. Also Suitable To Rough Services / Installations. ( Bajaj / Philiphs / Havells / Wipro ) .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 127 Supplying And Fixing Of Monkey Guard Fixtures ( Iron / Steel Cover ) For Protection Of Post Of Lanturns Light Fitting With All As Required. Material Designing Must Be Discussed With Enginer In Charge And Before Supplying Its Design Approval Must Be Taken By Engineer In Charge. 128 Providing And Fixing 9 Watt Retrofit Led Bulbs For Guest House Etc…As Required. 129 Supply, Fixingand Commissioning Of Indoor Recess / Surface 160X160mm ( 1X1 ) A L.E.D. Panel Light 18 Watt Equipped With Motion Sensor, Will Work Only At 3.5 Watt / Go Off When Nobody Is Around The Light. Will Go To 18 Watt At Full Intensity As Soon As Any Motion Occurs Around Light . Saves About 75% Electricity With All Acceossiers Etc. As Required.The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 130 Supply, Fixingand Commissioning Of Indoor Recess / Surface A L.E.D. Panel Light 12 Watt Equipped With Motion Sensor, Will Work Only At 3.0 Watt / Go Off When Nobody Is Around The Light. Will Go To 12 Watt At Full Intensity As Soon As Any Motion Occurs Around Light. Saves About 75% Electricity With All Asseossries Etc. As Required.The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
46.
Housing Urban and Rular Development #10485918 Price Bid
Tender For Electric Maintenance Work In J.K Lon Hospital , Jaipur -Wiring Of Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Gradeand 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) Inrecessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItSisi Marked ( Is:3419-1988 ) Accessories, Round Tiles, 1.2 Mm Thickhot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder / 3 Way Connector, Screws, Making Connections, Testing Etc. As Required.For Specification Of Copperconductor, Phenolic Laminated SheetS & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 Short Point ( Up To 3 Mtr. ) 3 Medium Point ( Up To 6 Mtr. ) 4 Long Point ( Up To 10 Mtr. ) 5 Wiring Of 3 / 5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Sizefr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Gradeand 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) Inrecessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked ( Is:3419-1988 ) Accessories, Hot Dipped Galvanizedmodular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modularswitch, 3 / 5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required.For Specification Of Copperconductor, Phenolic Laminated SheetS & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 6 On Board 7 S&F Following Sizes ( Dia. ) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along Withisi Marked ( Is:3419-1988 ) Accessories As Requiredinrecessincludingcutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 8 20 Mm 9 25 Mm 10 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130 / Iec 60228 Forlower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A / C / D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 1 X 1.5 Sq.Mm 12 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 13 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 14 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal / Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Ofisi Marked Modular 16 Amp. Switch ( Is :3854 ) And 6 / 16 Amp. Socket Outlet ( Is:1293 ) Making Connection , Testing , Etc. As Required. For Specification Ofwiring Accessories Refer Chaptere - 07Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 15 P & F Of Industrial Plug And Socket Conforming To Iec 60309-1 / 2 Made Out Of Self Extinguishing Engineering Polymer / Polyamide, Nickel Plated Brass Sleeve And Pins, Socket With Shutter Including Making Connection Etc As Reqd. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 16 Ip -67 Panel Mounted Socket 17 32 A 3 Pin ( 2P+E ) 18 Providing & Fixing Of Recessed / Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box Withprovision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing , Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door ( For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar, Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 19 Double Door Ik-09 & Ip-43 With Metal End Box 20 6 Way ( 8+18 ) 21 Providing & Fixing Of Recessed / Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For 3 / 4 Pole Mccb And Sp / Tp Mcb As Outgoing , Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door ( For Double Door Db Only ) Complete With Insulated 160 ( Upto 160 A Incomer ) / 250 Amp. Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar, Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 22 Double Door Ip-43 & Ik-09 With Provision Of Incomer Mccb 100 / 125 A Rating With Metal End Box 23 6 Way 24 Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity ( B / C / D Tripping Characteristic As Per Type Of Load Andsite Requirement ) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Ofclass 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted Inexisting Distribution Board / Sheets, Minimum Electrical Operation 20, 000 Upto 20 A Rating And 10, 000 Upto 63 A, 5000 For 80 A & Above Ratingincluding Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 25 Single Pole Mcb ( With B / C Curve Tripping Characteristics ) 26 6 A To 32 A Rating 27 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wounddouble Ball Bearing900 / 1400 Rpm Single Phaseexhaustfan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 28 300 Mm Sweep ( 900 / 1400 Rpm ) 29 380 Mm Sweep ( 900 / 1400 Rpm ) 30 450 Mm Sweep ( 900 / 1400 Rpm ) 31 Providing & Fixing Of 450 Mm Sweeposcillating Type Wall Mounting / Pedestal Typefans With Three Speed, On Andoff Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or Moreribs Guard; Three No. Aluminiumblades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum. / Min / Watt, Noise Level Should Be <= 75 Db, Power Consumption <= 120 Watts, Motor Protection Through Thermal Overload Protection Device, Including Fixing With Anchor Bolts, Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 32 Wall Mounting Type With Adjustable Vertical Angle 33 Providing & Fixing Of Ip20, 2X2 Led Surface / Recessedmounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal / External Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection ( Integral With Light Fixture ) . System Lumen Efficacy Of = 120 Lm / Watt , Thd < 10 % , P.F.=0.95, Cri >80 , Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing Onhousing. 34 Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 & Lm80 ) Certificate / Report From Oem Shall Be Submitted.All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 35 Recessed Mounting 36 Minimum Lumen Output 4200 Lm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
47.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
48.
Health and Family Welfare #10363172 Price Bid
Tender For Electrification Work In Phc Building At Khetasar Block Osian District Jodhpur; 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
49.
Housing Urban and Rular Development #10350279 Price Bid
Tender For Construction Of Labour Ward In Hostpitalgangashahar - Bikaner ( Electricalwork ) Construction Of Labour Ward In Hostpital Gangashahar - Bikaner ( Electricalwork ) - 1 Note:-Please read Annexure A for each Items if not uploaded in e tender, see on pwdraj website.Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 On board 7 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories with own OEM CM/L No. as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 8 20 mm 9 25 mm 10 32 mm 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 2 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 1 x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 1 x 6.0 sq.mm 16 4 x 16.0 sq.mm 17 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 18 Single pole MCB (With B/C curve tripping Characteristics) 19 6 A to 32 A rating 20 Four pole MCB (With B/C curve tripping Characteristics) 21 50/63 A rating 22 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 23 Metal door (Three phase) IK-09 and IP-43with Metal end box 24 6 Way 25 Providing & Fixing ofISI marked (IS:1293) 16 ampunbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 26 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 27 25 Amp.2 Moduleswitch With LedIndicator 28 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 25 Amp. 2 Module Socket 30 Providing & Fixing of modular type 100/120W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 5 step fan regulator 2 Module 32 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 33 Blanking plate 34 Modular MCB 6 A to 32 ASP 35 Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 36 1/2 Module 37 3 Module 38 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 1-2 Module 40 3 Module 41 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 42 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 43 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 44 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 45 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 46 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 47 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 48 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 49 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 50 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 51 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade 54 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Blue / white Colour 56 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 4 pole MCCB With Thermal Magnetic release 58 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 59 200 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 60 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 61 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 62 Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosuresuitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thickconforming to IS-8623-1 & 3 /IEC 61439- 1 & 3. powder painted complete with din railmaking internal DBterminations,detachable gland plate, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable 64 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 Open execution type 66 400 A 67 Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity, bus barfixed on porcelain/DMC insulators at approved spacingincluding making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 450 mm long , 4 strip 69 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 95.0 Sq. mm 71 3.5 core 72 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 73 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 74 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type )confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 75 50.0 Sq.mm 76 95.0 Sq.mm 77 Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 300mm x 50mm x 1.6mm 79 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 63mm 81 Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 82 17.2 mm thick and 3 Mtr. Long 83 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 84 32mm x6mm G.I. ( Hot Dipped) Strip 85 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 86 10 SWG G.I. ( Hot Dipped) Wire 87 Supply & Fixing of phenolic laminated boardof 6.4 mm thick forfresh air fan/exhaust fan up to size of 300 mm onexisting window frame including cost of board, cutting of hole , Nut bolts etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 89 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 90 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side complete with minimum weight of 750 gm. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 300 mm sweep 94 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 95 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 Up to 380 mm size 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 25 Ltr. 99 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 100 Recessed Mounting 101 Minimum lumen output 1300 lm 12 W 102 Minimum lumen output 1950 lm 18 W 103 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 104 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Recessed Mounting 106 Minimum lumen output 4200 lm 36W 107 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 108 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
50.
Health and Family Welfare #10349479 Price Bid
Construction Work Of Shc Building At Badgawda, District Pali- (PART - A : CIVIL WORK Rates are Based on PWD integrated BSR 2022)Earth work in surface excavation not exceeding 30 Cm. In depth but exceeding 1.5 meter in width as well as 10 Sam. on plan including disposal of excavated earth up to 50 Mtr. And lift up to 1.5 Mtr. Disposed soil to be leveled and neatly dressed : All kinds of soil. 2 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter.All kinds of soil. 3 Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level 1:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size (Crusher Broken) 4 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth , consolidatingeach deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr. 5 Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall in : Cement Mortar 1:6 (1-Cement:6-Sand). 6 Random Rubble stone masonary for superstructure above plinth level one storey height above 30 Cm. thick walls in : Cement Mortar 1:6 (1-Cement:6-Sand). 7 Add extra for facing as per design and detail specification including addidtion cost of stones Course rubble facing second sort 8 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 10 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 12 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) TMT bar (conforming of relevent IS code) 13 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 ,Cement mortar 1 : 6 (1 cement : 6 coarse sand) + Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . 14 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :CM: 1:6 15 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 16 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal, dehydreresin in glue both sides with approved steel fittings complete as per Annexure ‘A’ Decorative Teak veener both side 30 mm thick shutter 17 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 18 Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area ofdoor shutter to be measured) : 19 Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge Window openable. 20 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 21 Renewing glass panes, with puty and nails wherever necessary:4 mm thick plain glass panes. 22 Grading roof water proofing treatment with : Cement concrete 1:2:4 (1-Cement:2-coarse sand :4-graded stone aggregate 20mm nominal size). 23 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 24 Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. 25 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. SIze 600mm x 600mm 26 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 27 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tile confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). size 300mm x 300mm 28 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished:25mm thick. 29 Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 ofIS 15658:2006 Category‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 30 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete.75mm thick with 20mm thick nominal size aggregate 31 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete new plastered surface ( three or more coats) 32 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. 33 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Three or more coats). 34 Painting with enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work. 35 Providing and fixing to existing door frames.30mm thick factory made solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15 mm x15mm , top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered in 45 degreeon the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter). 36 Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing complete jalore (p-white/ s-white/ rosy pink colour ) Size above 3600 Cm2 37 P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant 110mm dia 38 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: a) Bend 87.5110mm 39 b) Pipe clip 110mm 40 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) dark shade using ordinary cement 41 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : Flush/Ruled/Struck or weathered pointing 42 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 43 Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). 44 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) A.Grade 304 45 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 46 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 47 P & F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : Size Size 580x440 mm. 48 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 49 P & F water closet Seat Covers with brass hinges complete :Solid PVC (IS 2548 marked) grade-I White for EWC. 50 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 51 P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall :PVC with PVC bend as per IS : 7231 52 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 550mm x 400mm 53 P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : fire clay glazed kitchen sink ( I.S 771 - 1985 Marked size 600 x 450 x 250mm. 54 P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-chargesize 500 x 400mm 55 P&F towel rail or ring of approved quality /make: C.P. brass Towel rail elbow type with concealed screws size 600mm (heavy duty) 56 Providing and fiixng C.P. flange for 15mm dia tap.s 57 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 15 mm nominial size 58 25 mm nominal size 59 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).15 mm nominal size 60 25 mm nominal size 61 P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : a) C.P. Brass bib cock, 15 mm nominal bore. 62 b) Long body, 15 mm nominal bore weight not less than 690 gm.B628 63 c)Elbow action, 15 mm nominal bore. 64 P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete : Brass wt. 400 gm, 15 mm. 65 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15 mm Brass (IS:8931 marked). 66 P & F 15 mm. Dia Connection pipe of approved quality/make: PVC pipe with C.P. Brass nuts up to length 450 mm. 67 P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : a) Gun-metal 15 mm nominal bore. 68 b) Gun-metal 25 mm nominal bore. 69 P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. a) 500 litres capacity. 70 Construction of chamber in all type of soil with 300 mm thick masonry in Cm 1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 300x300mm depth upto 0.5m cement cover with frame 71 Construction of soakage well in all type of soil 300 mm thick dry masonry top and bottom 300 mm course in CM 1:6, 80 mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring, earth work complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 300 Cm. dia outside & 300 Cm. depth. 72 Providing and fixing unplasticized Poly Vinyl Chloride (UPVC) SWR pipes type `B for sciland waste dischareg system (IS : 13592: 1992 marked) of approved quality/ make. a) 75mm dia 73 b) 110mm dia 74 Providing and fixing unplasticized Poly Vinyl Chloride (UPVC) SWR pipes type `B for sciland waste dischareg system (IS : 13592: 1992 marked) of approved quality/ make. a) Bend 87.5 Dg. 75mm dia. 75 b) Bend 87.5 Dg. 110mm dia. 76 c) Door Bend 87.5Dg. 110mm dia. 77 d) Nahni Trap with Jali 4110mm dia 78 e) Vent Cowel 75mm dia. 79 (PART (B) : BRANDING WORK)Making of Health Wellness Centre pattern (Gola) including colour picture work inside for façade branding incl. material, labour & T&P as per direction of Engineer-in-charge. 80 Making of Border of window for Health Wellness Centre as per given pattern for Branding including material, labour & T & P as per direction of Engineer-in-charge. Upto window size 4 x 56 as per standard drawing/ pattern 81 (PART-C : Rates are Based on Electrical BSR 2022) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 82 Short point (up to 3 mtr.) 83 Medium point (up to 6 mtr.) 84 Long point(up to 10 mtr.) 85 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 86 On board 87 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 2 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 88 1 x 1.5 sq.mm 89 2 x 2.5 sq. mm. + 1x1.5sqmm 90 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 91 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 92 Single pole MCB (With B/C curve tripping Characteristics) 93 6 A to 32 A rating 94 Double pole isolator 95 63 A rating 96 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 97 Metal door (single phase) IK-09 and IP-43 with Metal end box 98 6 Way (6+2) 99 12 Way (12+2) 100 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories with own OEM CM/L No. as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 101 20 mm 102 25 mm 103 Providing & Fixing of modular type 100/120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 5 step fan regulator 2 Module 105 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 106 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 107 IP -67 Surface/Wall mounted socket 108 32 A 3 pin(2P+E) 109 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 110 300 mm sweep(900/1400 RPM) 111 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 112 Up to 380 mm size 113 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 114 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 115 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 116 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 117 Surface Mounting (with extruded alumn. Housing ) 118 Minimum lumen output 1300 lm 119 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 120 LED Street Light fixture with Minimum lumen output 5600 lm 121 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 20 mm Dia. 123 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 10 Ltr. 125 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 127 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 128 16.0 Sq. mm 129 2 core 130 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 131 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 132 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 133 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 134 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 135 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 136 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 137 17.2 mm thick and 3 Mtr. Long 138 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 8 SWG copper Wire 140 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 25mm x 3mm copper strip 142 25mm x 3mm G.I. ( Hot Dipped) Strip 143 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 144 Providing & Fixing of1200 mm sweepBLDC technologypower savingceilingfanwhich can withstand on votage fluctuationsfrom 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10%and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe up to 80 cm, cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 Without Remote 146 Providing & Fixing of 400 mm SweepBLDC technology Oscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Double Wall bearing withfront and back 120 or moreribs guard; Three no.blades, noise level should be <= 75 dB,including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 147 Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM 148 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 149 4 kg 150 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 151 6.4 mm thick 152 SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 153 For single phase Submersible / Monoblockpump 154 0.5 HP to 1.5 HP (DOL starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
TenderDetail
Loading tenders